CASTLES TECHNOLOGY VEGA3000-3G EFTPOS User Manual VEGA5000 Book 2

CASTLES TECHNOLOGY CO., LTD. EFTPOS VEGA5000 Book 2

User Manual

Download: CASTLES TECHNOLOGY VEGA3000-3G EFTPOS User Manual VEGA5000 Book 2
Mirror Download [FCC.gov]CASTLES TECHNOLOGY VEGA3000-3G EFTPOS User Manual VEGA5000 Book 2
Document ID2569014
Application IDOACtZTLddCUmTp0NYP+K1A==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize182.48kB (2280951 bits)
Date Submitted2015-03-29 00:00:00
Date Available2015-03-29 00:00:00
Creation Date2015-03-17 18:42:22
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2015-03-17 18:42:22
Document TitleVEGA5000(S) Book 2 User Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Anfernee Lin

CASTLES TECHNOLOGY
VEGA3000 EFT-POS
Book 2
User Manual
Confidential
Version1.0
Jan 2015
Castles Technology Co., Ltd.
2F, No. 205, Sec. 3, Beixin Rd., XindianDistrict,
New Taipei City 23143, Taiwan R.O.C.
http://www.castech.com.tw
Revision History
Version
Date
Descriptions
1.0
May 27, 2014
Initial creation.
1.1
Jan 14, 2015
Add FCC Warning
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 2
Contents
1.
Introduction .................................................................................................................. 5
1.1.
2.
3.
Type of Terminal .................................................................................................. 5
Hardware Setup............................................................................................................ 7
2.1.
Parts of the Terminal ........................................................................................... 7
2.2.
Inserting the Battery........................................................................................... 10
2.3.
Inserting the SAM Card ..................................................................................... 11
2.4.
Inserting the Paper Roll ..................................................................................... 12
2.5.
Inserting the GSM SIM Card .............................................................................. 13
2.6.
Inserting the Memory card ................................................................................. 14
2.7.
Power Supply Specifications .............................................................................. 15
2.8.
Operating Ambient Temperature........................................................................ 15
Basic Operation ......................................................................................................... 16
3.1.
Program Manager .............................................................................................. 16
3.2.
Download AP ..................................................................................................... 16
3.3.
System Info........................................................................................................ 18
3.4.
Memory Status .................................................................................................. 19
3.5.
System Settings ................................................................................................. 20
3.6.
Test Utility .......................................................................................................... 23
3.7.
Factory Reset .................................................................................................... 26
3.8.
Power Off .......................................................................................................... 27
3.9.
Function Key Password Change ........................................................................ 28
3.10. Share Object Management ................................................................................ 29
3.11. CastlesTMS ....................................................................................................... 30
3.12. Font Mng ........................................................................................................... 31
3.13. Debug Tools ...................................................................................................... 32
3.14. ULD Key Hash ................................................................................................... 33
3.15. Hardware Detect ................................................................................................ 34
4.
Secure File Loading ................................................................................................... 35
4.1.
ULD Key System ............................................................................................... 35
4.1.1. ULD Manufacturer Key ........................................................................... 35
4.1.2. ULD User Key ........................................................................................ 37
4.1.3. Key Change ........................................................................................... 37
4.2.
File Signing ........................................................................................................ 38
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 3
4.2.1. Signing Kernel Module ........................................................................... 38
4.2.2. Signing User Files .................................................................................. 40
4.3.
File Loading ....................................................................................................... 44
4.3.1. Download by User Loader ...................................................................... 44
4.3.2. Download by Removable Media ............................................................. 47
4.4.
5.
6.
Font Management ...................................................................................................... 56
5.1.
Loading New Font.............................................................................................. 56
5.2.
Custom Font ...................................................................................................... 59
5.3.
Using TrueType Font (TTF) ............................................................................... 67
Technical Notes ......................................................................................................... 69
6.1.
7.
Changing ULD User Key.................................................................................... 49
Serial Cable PIN Assignment ............................................................................. 69
FCC Warning .............................................................................................................. 70
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 4
1. Introduction
This document provides a guideline on operating and configuringCastles VEGA3000
terminal.
The scope of this document includesetting up the terminal, basic operation, application
life cycle, and some advance features.
1.1. Type of Terminal
VEGA3000 terminal is portable type can be battery operated.
Portable type is designed as two pieces of hardware, handset and base unit.
Handset unit features major components, and also optional contactless reader,
WiFi, GRPS modem. Wired connection like power, modem, Ethernet, USB or
serial ports, are be located in base unit. There are additional power connection
and USB port on handset unit, allow the handset unit can be operated alone.
Handset
Front View
Base
Rear View
Front View
Rear View
Side View
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 5
To start up the terminal needs to press “Power Button” key after the adapter
connected.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 6
2. Hardware Setup
2.1. Parts of the Terminal
Front
10
VEGA3000
1. LCD Display (Color TFT)
7. Magnetic Stripe Reader
2. Privacy Shields
8. Smart Card Reader
3. Keyboard
9. Contactless Card Landing
4. Cancel Key
5. Clear Key
Zone
10. Paper Roll Handle
6. Enter Key
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 7
Rear
12 13
11
14
17
18 15
16
VEGA3000
Rechargeable
Battery
VEGA3000
VEGA3000
11. RechargeableBattery
Cover
12. Battery Cover Lock
13. Base Connector
14. SAM Slots
15. Micro SD Card Slot
16. GSM SIM Card Slots
17. RTC Battery
18. Battery Connector
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 8
Side
19
20
VEGA3000 Portable
19. Power Connector
20. USB Port
Base (Portable)
21
23
29
24
25
26
27
28
22
21. Base Connector
26. Com port 1
22. Base LED
27. Modem - Line Port
23. Power Connector
28. Ethernet Port
24. Com port 3
29. Micro USB Port
25. Com port 2
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 9
2.2. Inserting the Battery
Step 1
Align
Step 2
Step 1: Remove battery cover
Step 2: Insert battery into compartment, battery contact point must align with
batteryconnector.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 10
2.3. Inserting the SAM Card
SAM2
SAM1
SAM4
SAM3
VEGA3000 Portable
Step 1: Remove battery cover / back cover
Step 2: Insert SAM card into desire slot.
SAM 1 & 2:
Gold contact at lower side of card and facing right.
SAM 3 & 4:
Gold contact at lower side of card and facing left.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 11
2.4. Inserting the Paper Roll
Step 3
Step 2
Step 1
Step 1: Pulluppaper roll box handle.
Step 2: Gentle open paper roll cover.
Step 3: Insert paper roll as direction showed.
Paper specification
Width: 57mm
Outside diameter: 40mm
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 12
2.5. Inserting the GSM SIM Card
SIM1
SIM2
VEGA3000 Portable
Step 1: Remove battery cover / back cover
Step 2: Open SIM socket and insert GSM SIM card into desire slot.
SIM 1 & 2:
Gold contact at upper side of card and facing down.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 13
2.6. Inserting the Memory card
Micro SD
VEGA3000 Portable
Step 1: Remove battery cover / back cover
Step 2: Insert Micro SD memory card.
Micro SD :
Gold contact at lower side of card and facing right.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 14
2.7. Power Supply Specifications
I/P: 9Vdc, 4A
2.8. Operating Ambient Temperature
Range : 0° ~ 50°
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 15
3. Basic Operation
3.1. Program Manager
Upon power on, terminal will enter Program Manager if not default application
selected. All user applications are list in Program Manager. User may select an
application and run the application or view the application info, delete the
application or set to default run upon power on. User may enter System Menu to
configure terminal settings.
Program Manager
Program Manager
-----------01/02
1.App1
2.App2
0:Download

Press[0] button to enter System Menu.

Press [1] button to toggle default application selection.

Press [2] button to delete application.

Press [3] button to view application info.

Press [OK] button to run application.

Press [Power] or [.] buttonas up and down bottonto select application.
System Menu
Page 1

Page 2
System Menu
1.Download AP
2.System Info
3.Memory Status
4.Sys Settings
5.Test Utility
6.Factory Reset
7.Power Off
8.FK PWD Change
9.Share objMng
System Menu
1.Castles TMS
2.FontMng
3.Debug Tools
4.ULD KEY HASH
5.HW Detect
Down: Next Page
Up:Prev Page
Press [.] button to page 2.
3.2. Download AP
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 16
Download user application or kernel modules firmware.
System Menu
System Menu
1.Download AP
2.System Info
3.Memory Status
4.Sys Settings
5.Test Utility
6.Factory Reset
7.Power Off
8.FK PWD Change
9.Share objMng
Down: Next Page

Press [1] button to enter Download AP menu.
Download AP Menu
Download EX
1.RS232 or USB
2.USB Disk
3.SD Card
Select DW Source
Select download source:

Press [1] button to select source as RS232 or USB connection and enter ULD
download mode.

Press [2] button to select source as USB disk.

Press [3] button to select source as SD card.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 17
3.3. System Info
View kernel module firmware information.
System Menu
System Menu
1.Download AP
2.System Info
3.Memory Status
4.Sys Settings
5.Test Utility
6.Factory Reset
7.Power Off
8.FK PWD Change
9.Share objMng
Down: Next Page

Press [2] button to enter System Info menu.
System Info Menu
Page 1
SYSTEM INFO
---Kernel Ver--BIOS
: VR0016
SULD
: VRF014
LINUXKNL: VR0019
ROOTFS : VR0010

Page 2
SYSTEM INFO
--- KOVer --SECURITY: VR0025
KMS
: VR0024
DRV: VR0039
USB: N/A
SAM: VR0028
CL
: VR0018
SC
: VR0011
Page 3
SYSTEM INFO
--- SOVer--UART
: VR0014
USBH
: VR0011
MODEM
: VR0014
ETHERNET: VR0029
FONT
: VR0025
LCD
: VR0034
PRT: VR0020
RTC
: VR0013
ULDPM
: VR0022
PPP MODEM: VR0026
KMS: VR0025
FS
: VR0015
GSM
: VR0022
BARCODE : VR0013
Press [.] button to next page.
Page 4
SYSTEM INFO
--- SO Ver2 --TMS
: VR0014
TLS
: VR0011
CLVW
: VR0019
CTOSAPI : VR0033
Castles Technology Co., Ltd.
Page 5
SYSTEM INFO
--- HWMVer --CRDL/ETHE:ONCHIP
CLM-MP
: N/A
--- APVer --ULDPM
: VR0028
Confidential • All Right Reserved.
Page 6
SYSTEM INFO
HUSB ID:00000000
CUSBID:N/A
--Factory S/N--FFFFFFFFFFFFFFFF
Pg. 18
Page 7
SYSTEM INFO
-EXT SO Ver P.1 CRDLMDL : VR0100
CACLENTRY: VR0100
CAMPP: VR0300
CAVPM
: VR0012
CAEMVL2 : VR0013
CAEMVL2AP: VR0004
3.4. Memory Status
View terminal flash memory and RAM information.
System Menu
System Menu
1.Download AP
2.System Info
3.Memory Status
4.Sys Settings
5.Test Utility
6.Factory Reset
7.Power Off
8.FK PWD Change
9.Share objMng
Down: Next Page

Press [3] button to enter Memory Status menu.
Memory Status Menu
MEMORY STATUS
--FLASH Memory-Total:
31616KB
Used :
22640KB
--SDRAM Memory-Total:
31872KB
Used :
10908KB
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 19
3.5. System Settings
View or change terminal system settings.
Setting
Descriptions
Key Sound
Enable (Y) or disable (N) the beep sound when
pressing any key.
Exec DFLT AP
Enable (Y) or disable (N) execution of default
selected application.
USB CDC Mode
Enable (Y) or disable (N) USB CDC mode.
FunKey PWD
Enable (Y) or disable (N) password protection to
access function key (0 ~ 3) in Program Manager.
PMEnter PWD
Enable (Y) or disable (N) password protection to
enter Program Manager.
SET USB Host
Enable (Y) or disable (N) USB host mode.
Base USB CDC
Enable (Y) or disable (N) USB CDC mode in base
unit. [Portable model only]
List SHR Lib
Enable (Y) or disable (N) to list all shared libraries
in Program Manager.
Key MNG Mode

Bat Threshld
Battery charging threshold value. [Portable model
only]
Null Cradle
Enable (Y) if base is null cradle. [Portable model
only]
Debug Mode
Enable (Y) or disable (N) console debug mode.
Debug Port
Serial port for console debug.
Mobil AutoON
Enable (Y) or disable (N) to auto turn on GSM
module after start up the terminal.
Bklit Auto Off
Enable (Y) or disable (N) Auto OffLCDBacklight
Bklit Off Time
Thresholdof Auto Off LCD Backlight
PWR KEY OFF
Enable (Y) or disable (N) Power key rebooting
GDB Mode
Enable (Y) or disable (N) GDB mode.
GDB Timeout
GDB connection timeout.
GDB Channel
GDB connection channel.
ETHER IP/PORT
GDB Ethernet connection setting.
RTC Time Zone
Set Time Zone of Real Time Clock.
NTP Enable
Enable (Y) or disable (N) Network Time Protocol.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 20
NTP Update Freq
Frequency of Network Time Protocol updating.
System Menu
System Menu
1.Download AP
2.System Info
3.Memory Status
4.Sys Settings
5.Test Utility
6.Factory Reset
7.Power Off
8.FK PWD Change
9.Share objMng
Down: Next Page

Press [4] button to enter System Settings menu.
System Settings Menu
Page 1






SYS SETTINGS
Key Sound
: Y
Exec DFLT AP: Y
-AP Name
USB CDC Mode: Y
FunKeyPWD :N
PMEnterPWD:N
SET USB Host: N
Base USB CDC: X
List SHR Lib: N
Key MNG Mode: 0
Bat Threshld: X
Null Cradle : X
Debug Mode :N
Debug Port :X
2: Next Page

Press [Power] or [.]button to select setting.

Press [OK] button to change the setting value.

Press [] button to toggle Y  N  Y.

Press [2] button to next page.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 21
Page 2
SYS SETTINGS
Mobil AutoON: N
Bklit Auto Off:X
Bklit Off Time: N
PWR KEY OFF:N
GDB Mode:X
GDB Timeout: X
ETHER IP/PORT
RTC Time Zone :GMT
NTP Enable:N
NTP Update Freq:X
1:PrevPage

Press [Power] or [.]button to select setting.

Press [OK] button to change the setting value.

Press [] button to toggle Y  N  Y.

Press [1] button to previous page.

Press [2] button to next page.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 22
3.6. Test Utility
Perform terminal hardware components diagnostic.
System Menu
System Menu
1.Download AP
2.System Info
3.Memory Status
4.Sys Settings
5.Test Utility
6.Factory Reset
7.Power Off
8.FK PWD Change
9.Share objMng
Down: Next Page

Press [5] button to enter Test Utility menu.
Test Utility Menu
Page 1
Main Menu 0014
1:LCD
2:Key Board
3:FLASH
4:Smart Card
5:Backlight
6:MSR
7:LED
8:RTC
9:Printer
10:FONT
11:CL_Transparent
12:CL Card Test
13:SD Card Test
14:Wi-Fi Test

1/2

Press [1] and [OK] button to diagnose LCD.

Press [2] and [OK] button to diagnose keyboard.

Press [3] and [OK] button to diagnose flash memory.

Press [4] and [OK] button to diagnose smart card module.

Press [5] and [OK] button to diagnose backlight.

Press [6] and [OK] button to diagnose magnetic stripe reader.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 23

Press [7] and [OK] button to diagnose LED.

Press [8] and [OK] button to diagnose real time clock.

Press [9] and [OK] button to diagnose printer.

Press [1], [0]and [OK] button to view font.

Press [1], [1] and [OK] button to diagnose contactless reader in transparent
mode.

Press [1], [2]and [OK] button to diagnose contactless card.

Press [1], [3] and [OK] button to diagnose SD memory card.

Press [1], [4] and [OK] button to test Wi-Fi.

Press [.] button to next page.
Note: Default password for changing RTC is 8418.
Page 2
Main Menu 0014
15:Power Saving
16:Comm Menu
 2/2

Press [1], [5]and [OK]button to enter Power Saving Test Menu.

Press [1], [6] and [OK] button to enter Communication Test Menu.

Press [Power] button to previous page.

Press [X] button to exit.
Power Saving Test Menu
Power Saving Test
1. Standby Mode
2. Sleep Mode

Press [1] button to Standby Mode.

Press [2] button to Sleep Mode.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 24
Communication Test Menu
Communicate
1. COM1 2.
3. Com3
4. Ethernet
5. USB
6. Modem
7. GPRS
8. All
Test
Com2
Test
Test
Test
Test
Test

Press [1] button to diagnose Com 1.

Press [2] button to diagnose Com 2.

Press [3] button to diagnose Com 3.

Press [4] button to diagnose Ethernet module.

Press [5] button to diagnose USB.

Press [6] button to diagnose modem.

Press [7] button to diagnose GPRS.

Press [8] button to diagnose all, from item 1 to 7.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 25
3.7. Factory Reset
Perform factory reset, all user application, fonts and data will be deleted.
System Menu
System Menu
1.Download AP
2.System Info
3.Memory Status
4.Sys Settings
5.Test Utility
6.Factory Reset
7.Power Off
8.FK PWD Change
9.Share objMng
Down: Next Page

Press [6] button to enter Factory Reset menu.
Factory Reset Menu
Factory Reset
OK to reset ?

Press [OK] button to perform factory reset.
Factory Reset
Password :
****

Enter factory reset password.Default password: 8418
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 26
3.8. Power Off
Power off terminal.
System Menu
System Menu
1.Download AP
2.System Info
3.Memory Status
4.Sys Settings
5.Test Utility
6.Factory Reset
7.Power Off
8.FK PWD Change
9.Share objMng
Down: Next Page

Press [7] button to power off terminal.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 27
3.9. Function Key Password Change
Change function key access password.
System Menu
System Menu
1.Download AP
2.System Info
3.Memory Status
4.Sys Settings
5.Test Utility
6.Factory Reset
7.Power Off
8.FK PWD Change
9.Share objMng
Down: Next Page

Press [8] button to enter FunKey Password menu.
FunKey Password Menu
FunKey Password
Enter Password:
****

Enter current password. (Default password is "0000")
FunKey Password
New Password:
****
Confirm Password
****

Enter new password.

Enter new password again to confirm.
FunKey Password
New Password:
****
Confirm Password
****
PWD Changed OK
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 28
3.10.Share Object Management
View share object in terminal.
System Menu
System Menu
1.Download AP
2.System Info
3.Memory Status
4.Sys Settings
5.Test Utility
6.Factory Reset
7.Power Off
8.FK PWD Change
9.Share objMng
Down: Next Page

Press [9] button to enter Share Object Management menu.
Share Object Management Menu
Share objMng
1.Share LIB
2.Share File

Press [1] button to view shared library.

Press [2] button to view shared file.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 29
3.11.CastlesTMS
Connect to TMS (Terminal Management Software) server, set or delete TMS
configuration.
System Menu (Page 2)
System Menu
1.Castles TMS
2.Font Mng
3.Debug Tools
4.ULD KEY HASH
5.HW Detect
Up:Prev Page

Press [1] button to enter Castles TMS menu.
Castles TMS Menu
CASTLES TMS
1.Connect Server
2.SetConfig
3.DelConfig

Press [1] button to connect to TMS server.

Press [2] button to set TMS configuration.

Press [3] button to delete TMS configuration.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 30
3.12.Font Mng
View Font Management.
System Menu (Page 2)
System Menu
1.Castles TMS
2.Font Mng
3.Debug Tools
4.ULD KEY HASH
5.HW Detect
Up:Prev Page

Press [2] button to view Font Management.
FontManagment
Font Mng
1.FNT File
2.TTF File

Press [1] button to view FNT Font list.

Press [2] button to view TTF Font list.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 31
3.13.Debug Tools
Perform the Debug Tools.
System Menu (Page 2)
System Menu
1.Castles TMS
2.Font Mng
3.Debug Tools
4.ULD KEY HASH
5.HW Detect
Up:Prev Page

Press [3] go to the Debug Tools Menu.
Debug Tools
Debug Tools
1.CoreDump
2.Debug Log

Press [1] go get the Core Dump error from terminal.

Press [2] go to the Debug Log Menu.
Debug Log
Debug Log
1.Upload
2.Clean All

Press [1] get the Debug Log from the memory of terminal to SD card.

Press [2] clean all the Debug Log from the SD card.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 32
3.14.ULD Key Hash
View ULD user keyset hash value.
System Menu (Page 2)
System Menu
1.Castles TMS
2.Font Mng
3.Debug Tools
4.ULD KEY HASH
5.HW Detect
Up:Prev Page

Press [4] button to view hash value.
USER ENC KEY
9572BC621C1D5406
0856D00BCC207000
D3320077
USER SIGN KEY
A927768EA7DD7B9E
7E3F395C10726B6F
43B35C5A
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 33
3.15.Hardware Detect
View the hardware type of the termianl.
System Menu (Page 2)
System Menu
1.Castles TMS
2.Font Mng
3.Debug Tools
4.ULD KEY HASH
5.HW Detect
Up:Prev Page

Press [5] button to view the hardware type of the termianl.
HW TYPE
Qriginal
HW-TYPE :MEGC
New
HW-TYPE :MEGC
Please Any Key.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 34
4. Secure File Loading
Castles implemented an interface in terminal named User Loader(ULD) to provide secure file
loading to system memory. Loading of user application, kernel firmware, font and others
must use User Loader.
The loading process is secure by signing the files using ULD Key System.
4.1. ULD Key System
The ULD Key System uses two key sets for securely managing the kernel
updating and application downloading. Each key set contains two RSA key pairs.
One is used for key encryption and the other is used for signature. These two key
sets are specified as below:
ULD Manufacturer Key Set

ULD Manufacturer Key Encryption Key (RSA)

ULD Manufacturer Signature Key (RSA)
ULD User Key Set

ULD User Key Encryption Key (RSA)

ULD User Signature Key (RSA)
For VEGA3000, the RSA key length is 2048bits.
4.1.1. ULD Manufacturer Key
The system consists of several kernel modules. These kernel modules
are provided by the Manufacturer, and released in CAP format file with
encryption and signing via ULD Manufacturer Keys.
The ULD Manufacturer keys are managed and maintained by the
manufacturer. The manufacturer uses these keys to generate kernel
CAP files for updating the system. However, the system is not permited
to be updated with these kernel CAP files directly generated by the
manufacturer. This is because only the user can have the privilege to
decide whether the system is to be updated. Therefore, before system
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 35
updating, the kernel CAP files must be “signed” via ULD User Key to get
the user permission. For simple expression, we call the kernel CAP files
generated by the manufacturer as “unsigned kernel CAP(s)” and call the
kernel CAP files “signed” by the user later as “signed kenel CAP(s)”.
Notes:
1. Tthe kernel modules are encrypted by a random-generated 3DES
key, which is retrieved from the Key Encryption Block of the CAP by
ULD Manufacturer Key Encryption Key, not directly encrypted by ULD
RSA Key.
2. The “sign” action via ULD User Keys actually is done by” the second
encryption”. “The second encryption” is done by using the randomgenerated 3DES key, which is encrypted by ULD User Key Encryption
Key, to perform Triple DES encryption again on the cipher data segment
of the kernel CAP files. This ensures that the system cannot retrieve the
correct data from the kernel CAPs without the user permission.
ULD Manufacturer
Keys
Kernel Module
CAP Generator
Unsigned Kernel
CAPs
ULD User Keys
Unsigned Kernel
CAPs
Castles Technology Co., Ltd.
CAP Signing Tool
Confidential • All Right Reserved.
Signed Kernel CAPs
Pg. 36
4.1.2. ULD User Key
ULD User Key are used to encrypt and sign the user/shared
applications. In addition, they are as goalkeepers to prevent the system
updating without user permission. This is done by the kernel CAPs
which are encrypted and signed by the manufacturer having to perform
the “signed’ action via ULD User Keys.
Notes: Applications are encrypted by a random-generated 3DES key,
which is retrieved from the Key Encryption Block of the CAP by ULD
User Key Encryption Key, not directly encrypted by ULD RSA Key.
ULD User Keys
Application
CAP Generator
Application CAPs
4.1.3. Key Change
The ULD RSA Keys are able to be changed. The system uses a special
CAP file, KEY CAP, for the manufacturer and user to change their own
keys. The KEY CAP contains a new set of ULD keys (Key Encryption
Key and Signature Key). These new keys are encrypted and signed via
the original keys. In other words, if the user would like to change the
ULD User Keys, they have to use their original ULD User Keys with the
new ULD User Keys to generate a KEY CAP.
Original ULD
Manufacturer/User
Keys
New ULD
Manufacturer/User
Keys
Castles Technology Co., Ltd.
Key CAP Generator
Confidential • All Right Reserved.
User KEY CAP
Pg. 37
4.2. File Signing
4.2.1. Signing Kernel Module
Castles will release new version of kernel module in “unsigned” form.
This files required to sign with ULD User Key before it can load to
terminal.
Castles Technology provideds a tool named “CAP Signing Tool” to
perform this task.
The CAP Signing Tool is located at:
C:\Program Files\Castles\VEGA3000\tools\Signing Tool

Run CAP Signing Tool
(VEGA3000)

Insert Key Card and select smart card reader
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 38

Enter Key Card PIN

CAP Signing Tool is ready, press “Select MCI File” button to browse
the file.

Output file will be located in “signed” folder.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 39
4.2.2. Signing User Files
Following files are required to sign before load to terminal. This is to
ensure the application data and codes confidential and integrity. The
output fille will be “CAP” file which is file format defined by Castles.

User application

User application data files

User application library

Font file

Share library

Share files

System setting

Key CAP (Manufacturer ULD Key Set)
Castles Technology provided a tool named “CAP Generator” to perform
this task.
The CAP Generator is located at:
C:\Program Files\Castles\VEGA3000\tools\CAPG (KeyCard)

Run CAP Generator
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 40

Insert Key Card and select smart card reader

Enter Key Card PIN
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 41

CAP Generator is ready, select the correct Type from the list.

Press “Step 1: Select AP Executable File” to select file to sign. This
is valid for all the files to sign.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 42

Enter file details and press “Step 2: Sign Application” to sign the file.
This is valid for all the files to sign.

The output file will be in a set. A “mci” file with one or more “CAP”
files.CAP file contents the signed file binaries, where MCI file
contents the list of CAP files.
App.CAP
App.mci
Note: If user would like to load multiple set of signed file, create a new
file with extension of “mmci”. Then put the mmci file contents with the list
of mci file.
MultiApp.mmci
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 43
4.3. File Loading
There are several ways of loading file to VEGA3000terminal.

Download by User Loader

Download by removable media

Download by user application

Download by Castles TMS
User Loader is a tool provided by Castles Technology. It’s the formal way to
download file to terminal.
User may implement their own ways of updating application or files using CTOS
API provided, CTOS_UpdateFromMMCI().
Castles TMS (CTMS or CASTLES Terminal Management System) is provided by
Castles Technology. It’s use to perform remote download via Ethernet,
GPRS/UMTS or modem.
4.3.1. Download by User Loader
The User Loader works for VEGA3000.
The Loader is located at:
C:\Program Files\Castles\VEGA3000\tools\Loader

Run User Loader
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 44

Select COM port

Browse and select mci file or mmci file

Setup terminal to enter download mode

Press [0] button in Program Manager (PM)

Press [1] button to select “1. Download AP“

Press [1] button again to select download via RS232 or USB
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 45

Press “Download” button to start.
Note: To download using USB cable, terminal must enable CDC mode.
Set USB CDC Mode to Y.
SYS SETTINGS
Key Sound
: Y
Exec DFLT AP: Y
-AP Name
USB CDC Mode: Y
FunKeyPWD
: N
PMEnterPWD : N
SET USB Host: N
Base USB CDC: X
List SHR Lib: N
Key MNG Mode: 0
Bat Threshld: X
Null Cradle : X
Debug Mode : N
Debug Port : X
2: Next Page
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 46
4.3.2. Download by Removable Media
The file download process can be achieved without PC by using
removable media, USB flash drive or MicroSD memory card. We
recommend don’t put unwantedfile to removable media, as it will
increase the time during detection.

Create a folder name “vxupdate” under root directory.
root
vxupdate

Place the mci file and cap file to “vxupdate” folder.
root
vxupdate
App.CAP
App.mci
Note: If user would like to load multiple application, create a new file
with extension of “mmci”. Then put the mmci file contents with the
list of mci file.
MultiApp.mmci
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 47

Insert removable media to terminal, and select the removable media
type in “Download AP” menu.
Download AP Menu
Download EX
1.RS232 or USB
2.USB Disk
3.SD Card
Select DW Source

Press [2] button to select USB flash drive.
Press [3] button to select MicroSD card.
Finally, terminal will process the file “vxupdate” folder.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 48
4.4. Changing ULD User Key
User may change their ULD User Key Set stored in Key Card. Castles
Technology provided a tool named “Secure Key Generator” to perform this task.

Run Secure Key Generator

Insert Key Card and select smart card reader

Enter Key Card PIN, default PIN is “1234”.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 49

To change Key Card PIN, press “Update PIN” button. If not, please skip this
steps.

Enter new PIN, enter new PIN again to confirm, then press [Enter] button
to change PIN in Key Card.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 50

To view current key set hash value, goto “Option” and select key.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 51

To generate new user key set

Please generate the RSA key by yourself,thelength of the RSA key set
should be 2048 (bits).

Copy RSA key components to RSA Key for Kenc in Secure Key
Generator.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 52

Generate second RSA key set for Signature.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 53

Click [Get Hash] button to calculate the hash value for key sets.

Please copy down all the values into a text file and keep in a safe place.
You will need this if you need to create duplicate Key Card.

To generate the key CAP for the newly generated user key set, press [Make
Key CAP File] button.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 54

The output file will be located in the Secure Key Generator folder.
SecureKeyGenerator
key.mci
key.cap

To update the newly generated key set to Key Card, press [Save to Card]
button to write the key set to Key Card.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 55
5. Font Management
5.1. Loading New Font

Run FontManager.exe
Located at C:\Program Files\Castles\Font Manager

Select font to download
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 56

Press [Setting] button to configure terminal type.

Select VEGA5000, press [Save] button to save and return font manager.

Press [Generate] to create the font file.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 57

Output file “Font.FNT” will be located at sub-directory named “Font” in “Font
Manager” folder.
Font Manager
Font
Font.FNT

Sign the file using CAP Generator, the type must set to “11 – Linux Font”.

Lastly, download the signed file (CAP file) to terminal using Loader.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 58
5.2. Custom Font
User may create font they preferred for displaying or printing on terminal.
There are two zone defined:
Zone 0x00 ~ 0x7F – ASCII characters, you may replace with the font type
preferred or your own language character set.
Zone 0x80 ~ 0xFF – Free to use, you may use for symbols.
Following steps demonstrate how to create a 12x24 font.

Run GLCD Font Creator

Select [File]  [New Font]  [Import An Existing System Font]
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 59

Select the font needed, simply choose a font size. The final value of font size
should be determine by the minimum pixel width. You may need to repeat this
steps few times to find the best fit font size.

Set the import range from 0 to 127.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 60

Check the minimum pixel width and height.

If the pixel width of the font size is larger than expected, then you have to
repeat the previous steps to import font with smaller size.

Use the following buttons to adjust the font size to match with expected font
size.
Add
columnonrigh
Removecolum
nonleft
Add column
on left
Removecolumn
onright
Add row on
top
Remove row
on bottom
Add row
on bottom
Castles Technology Co., Ltd.
Remove
row on top
Confidential • All Right Reserved.
Pg. 61

After adjust font size, select [File]  [Export for MicroElektronika].

Select output format as [mikroC].
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 62

Remove comment “// Code for char
“ from offset 0x00 to 0x1F. Remove
empty line if found. Then click [Save] button to save to file.
Remove
Remove
Remove
Remove

Run Font Manager Tool.

Click [Setting] button
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 63

Enter the file name, font id, and select the size.

Click [Create] button, and select the C file previously created using GLCD
Font Generator.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 64

Select [Font Manager] tab and tick the newly createdfont, and press
[Generate] button to export to FNT file.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 65

Use CAP Generator to conver the FNT file to CAP.
Set type to [11 – Linux Font], press [Step 1] button select the FNT file. Then
press [Step 2] to generate CAP file.

Download the font CAP file to terminal.

In terminal application, add following code to display message using the
newly created font.
CTOS_LanguageConfig(0xA000,d_FONT_12x24,0,d_FALSE);
CTOS_LanguageLCDSelectASCII(0xA000);
CTOS_LCDTPrintXY(1, 1, "ABCDEFGH");
Or print message using the newly created font.
CTOS_LanguagePrinterSelectASCII(0xA000);
CTOS_PrinterPutString("ABCDEFGH");
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 66
5.3. Using TrueType Font (TTF)
TrueType Font (TTF) is only supported in VEGA5000S terminal.You may
download the TrueType font preferred to terminal for displaying or printing.
Following steps demonstrate how to use “Cooper Black” TrueType font.

Copy the TTF file needed to a empty folder.
TTF
COOPBL.TTF

Use CAP Generator to conver the TTF file to CAP.
Set type to [11 – Linux Font], press [Step 1] button select the TTF file.
Then press [Step 2] to generate CAP file.

Download the font CAP file to terminal.
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 67

In terminal application, add following code to display message using the
newly added font.
CTOS_LCDTTFSelect("COOPBL.TTF", 0);
CTOS_LCDFontSelectMode(d_FONT_TTF_MODE);
CTOS_LCDTSelectFontSize(0x203C); // 32x60
CTOS_LCDTClearDisplay();
CTOS_LCDTPrintXY(1, 1, "Hello World");
Or print message using the newly added font.
CTOS_PrinterTTFSelect("COOPBL.TTF", 0);
CTOS_PrinterFontSelectMode(d_FONT_TTF_MODE);
CTOS_LanguagePrinterFontSize(0x203C, 0, 0); // 32x60
CTOS_PrinterPutString("Hello World");
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 68
6. Technical Notes
6.1. Serial Cable PIN Assignment
RJ12 6P6C
Male Plug
Castles Technology Co., Ltd.
1 ○ VCC
2 ○ TXD
3 ○ RTS
4 ○ RXD
5 ○ CTS
6 ○ GND
VCC ○ 1
RXD ○ 2
TXD ○ 3
○4
GND ○ 5
○6
RTS ○ 7
CTS ○ 8
○9
Confidential • All Right Reserved.
RS232
Female
Pg. 69
7. FCC Warning
Federal Communication Commission interference statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. -Increase the separation between the equipment
and receiver. -Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference received, including interference that may cause
undesired operation
RF Exposure Warning
The equipment complies with RF exposure limits set forth for an uncontrolled environment.
The antenna(s) used for this transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
You are cautioned that changes or modifications not expressly approved by the party
responsible for compliance could void your authority to operate the equipment.
This equipment should be installed and operated with a minimum distance of 20 centimeters
between the radiator and your body.
~ END ~
Castles Technology Co., Ltd.
Confidential • All Right Reserved.
Pg. 70

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 70
Language                        : zh-TW
Tagged PDF                      : Yes
Title                           : VEGA5000(S) Book 2 User Manual
Author                          : Anfernee Lin
Subject                         : VEGA5000(S) Book 2 User Manual
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2015:03:17 18:42:22+08:00
Modify Date                     : 2015:03:17 18:42:22+08:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WIYVEGA3000-3G

Navigation menu