CIG WF610 WF-610 2x2 dual band 802.11ac Outdoor AP User Manual SFK WF610 2015 08 26
CIG SHANGHAI CO., LTD. WF-610 2x2 dual band 802.11ac Outdoor AP SFK WF610 2015 08 26
CIG >
SFK-WF610_User Manual_2015.08.26
WF-610User Manual Version 2 TABLE OF CONTENTS 1 Quick Start ................................................................................................................... 4 1.1 Connect PoE Adapter to WF-610............................................................................................ 12 1.2 Configure PC’s IP Address...................................................................................................... 13 1.3 Visit WF-610 Web Page .......................................................................................................... 13 1.4 Configure Management Interface for WF-610 ........................................................................ 14 1.5 Connect WF-610 to Switch...................................................................................................... 14 1.6 Configure Location, Language ................................................................................................ 15 1.7 Configure Security Profile for Different Authentication Types................................................. 15 1.7.1 WEP ................................................................................................................................................. 15 1.7.2 WPA2-PSK ..................................................................................................................................... 16 1.7.3 WPA/WPA2-PSK ........................................................................................................................... 16 1.7.4 802.1X /EAP ................................................................................................................................... 16 1.7.5 WEB/MAC ....................................................................................................................................... 17 AP Mode .................................................................................................................... 19 2.1 AP Network Topology .............................................................................................................. 19 2.2 Enable AP Mode...................................................................................................................... 19 2.3 Configure Radio Parameters ................................................................................................... 20 2.4 Configure SSID........................................................................................................................ 20 2.5 Configure Rate Limit Rule (Optional) ...................................................................................... 21 2.6 Configure Group ID (Optional) ................................................................................................ 21 2.7 Configure MAC ACL Rule (Optional) ...................................................................................... 23 2.8 AP+WDS ................................................................................................................................. 23 2.8.1 AP+WDS Network Topology ........................................................................................................ 23 2.8.2 Enable WDS function .................................................................................................................... 23 2.8.3 Configure CPE WDS ..................................................................................................................... 24 WDS Bridge Mode ..................................................................................................... 25 3.1 WDS Bridge Network Topology .............................................................................................. 25 3.2 Enable WDS Bridge Mode ...................................................................................................... 25 3.3 Input Remote AP MAC ............................................................................................................ 25 3.4 Configuration on Remote AP................................................................................................... 26 3.5 NAWDS Auto Find ................................................................................................................... 26 Status......................................................................................................................... 27 4.1 Overview .................................................................................................................................. 27 4.2 Radio ....................................................................................................................................... 28 Management .............................................................................................................. 29 5.1 Backup/Import Configuration ................................................................................................... 29 5.2 Software Upgrade.................................................................................................................... 29 5.3 Factory Reset via WEB ........................................................................................................... 29 5.4 Reboot via WEB ...................................................................................................................... 30 5.5 Factory Reset via Sending Special Packet ............................................................................. 30 5.5.1 Factory Reset One Single Device ............................................................................................... 30 5.5.2 Factory Reset All Devices ............................................................................................................ 33 Troubleshooting ......................................................................................................... 34 6.1 6.2 6.3 6.4 Ping Diagnose ......................................................................................................................... 34 TraceRT Diagnose .................................................................................................................. 34 LED Definition .......................................................................................................................... 35 Debug via Telnet ..................................................................................................................... 35 1 Quick Start Thank you for buying this product. The following information aims to give you general information about product introduction, product overview and installation procedure and so on. 1. Introduction WF-610 is a dual-band 2x2 outdoor Wi-Fi AP, which is complied with the IEEE802.11n/11ac standard and designed for high-density deployments in offices, schools, hospitals and hotels that require premium performance. Having together MIMO (Multiple-in&Multiple-out) technology with high-throughput mode techniques, WF-610 works with most wireless terminals to builds a high capacity Wi-Fi network. 2. Package List • • • • AP x1 L shaped clamp x 1 Waterproof coverx 1 Installation packagex 1 3. Product Overview No. Name Function LAN Port 10/100/1000M Base-T Ethernet port (RJ-45), used as a WAN port and used for being powered by PoE function. See LED Definition LEDs 4. Installation To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read all warnings and precautions in this guide before installing or maintaining product. Caution To avoid risk of injury from electrical shock or energy hazard, installation and service of this product must be performed by qualified service personnel. Make sure the AP fits securely on the ceiling rail when hanging the device in the ceiling, because poor installation could cause it to fall and make body injury and equipment damage. Safety Statement • To avoid the abnormal work, do not install the device near the power line, electric lamp, power grid, or in any forceful power grid place • Ensure the power adapter is grounded well if install the device indoor. • Install other lightning protection equipment near the device if necessary, because the lightning protection module inside the device is basic. • Use the steady power grid to provide the power to the device, which is to avoid the abnormal work. • Use a less than 50m network cable to connect the PoE port, which is to acquire the steady power. The network cable complies with the DC resistance definition in the YD/926.2 protocol. Installation Environment • Operating ambient temperature: -40℃ ~ +65℃ • Operating ambient humidity: 5% ~ 95%non-condensing Installation mode: • Pole mounting Installation tool: • Screws, screw-driver and wrench Installation site: • Please ensure the visibility ofproduct and no tall buildings and woods block between them. Installation procedure Pole mounting 1. Firstly install the L shaped clamp, with M6 screw nut, spring washer and flat washer. Four screws need be installed. 2. Put the U shaped screw stem and U shaped slot into the hole. And then drive the M6 crew nut and M6 washer. 3. Install the clamp on the back of WF-610, with M6*12 screw bolt, M6 spring washer and M6 flat washer. Four screw bolts need be installed. 4. Input M6*12 screw bolt and M6 washer into the hole on the back and drive them. 5. Finall y mount WF610 on the pole as shown in the picture. And drive the screw nut tight with wrench. 5. LED Definition LED RUN LAN Function State-Color AP power / ready Steady - Green status Red Off Network Link Status Steady - Green Steady- Yellow Flashing Off 5G Hz Radio Status Steady– Green Off 2.4G Hz Radio Steady– Green Status Off Indication APis ready AP hardware failure No power to AP 1000Mbps Ethernet negotiated 10/100Mbps Ethernet negotiated Ethernet link activity Ethernet link unavailable 5GHz radio is enabled 5GHz radio is disabled 5GHz radio is enabled 5GHz radio is disabled link link 6. Software Installation Logging in to the Web Page 1. To configure PC IP address, fill 192.168.188.x in “IP address” and 255.255.255.0 in “Subnet mask”(set Window7 as an example to show the properties) 2. Input the default IP address 192.168.188.251 in the address bar of the web browser and press Enter. 3. Enter username and password (username: admin, password: password), after password authentication is successful, the web page is displayed. 7. Product Specification Physical specification Dimensions 216.2mm x 216.2 mm x 71mm(L x W x H) Weight 3.0kg LED RUN/ LAN/ RADIO 0/ RADIO 1 Ethernet interface RJ-45 connector Electrical specification Power input Power consumption Standard 802.3at PoE ≤12.33W Environmental specification Working temperature -40℃ ~ +65℃ Working humidity 5% ~ 95% non-condensing Elevations 86kPa~106kP0061 Dustproof and waterproof Lightning protection IP67 6KV common mode surge 8. Product Proper Disposal Waste of Electrical and Electronic Equipment Directive 2002/96EC on Waste of Electrical and Electronic Equipment are designed to tackle the fast increasing waste stream of electrical and electronic equipment and complements European Union measures on landfill and incineration of waste. CIG products at end of life are subject to separate collection and treatment in the EU Member Statues and therefore are marked with the symbol. European Union RoHS EU Restriction and Hazardous Substances Directive 2011/65/EC (RoHS) restricts the use of specific hazardous materials in manufacture of electrical and electronic equipment. Specially, restricted materials are Lead, Cadmium, Mercury, Hexavalent Chromium, and Bromine. CIG products comply with this requirement and all marked with “RoHS” shown at the left. China RoHS WF-610complies with China environmental declaration requirements and is labeled with “EFUP 20” label shown as follows. 部件名称 (Parts) 电路模块 (circuit modules) 电缆及电缆组件 (Mechanicalass emblies) 金属部件 (Metal Parts) 塑料和聚合物部 件 有毒有害物质声明 Hazardous Materials Declaration 有毒有害物质或元素(Hazardous Substance) 铅 汞 镉 (Pb) (Hg) (Cd) (Cr6+) (PBB) (PBDE) × 六价铬 多溴联苯 多溴二苯醚 (Plastic and Polymeric Parts) O: 表示该有毒有害物质在该部件所有均质材料中的含量在 SJ/T11363 - 2006 标准规定的限量要求下。 Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T11363-2006 standard. X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出SJ/T113632006标准规定的限量要求。 Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard. 对销售之日的所售产品,本表显示剑桥公司供应链的电子信息产品可能包含这 些物质。注意:在所售产品中可能会也可能不会含有所有所列的部件。 This table shows where these substances may be found in the supply chain of CIG electronic information products, as of the date of sale of the enclosed product. Note that some of the component types listed above may or may not be a part of the enclosed product. 除非另外特别的标注,此标志为针对所涉及产品的环保使用期标志。某 些零部件会有一个不同的环保使用期贴在其产品上。此环保使用期限只适用 于产品是在产品手册中规定的条件下工作。 The Environment-Friendly Use Period (EFUP) for all enclosed products and their parts are per the symbol shown here, unless otherwise marked. Certain parts may have a different EFUPand so are marked to reflect such. The Environment-Friendly Use Period is valid only when the product is operated under the conditions defined in the product manual. 9. Safety and Regulatory compliance WF-610has been tested and complied with the standards as follows: • • • FCC DOC Part 15 Class B (US) FCC Part 15 Subpart C 15.247 (US) FCC Part 15 Subpart E 15.407 (US) 10. FAQs FAQ Solution Check that the power adapter is plugged into a The RUN indicator is off live AC outlet. Check the power cable for shorts or breaks. 10 FAQ The LAN port indicator is off. Solution Check whether the connection between the LAN/POE port of the combiner and the LAN/POE port is correct. Check whether the connection between the LAN/POE port of the combiner and the LAN/POE port is correct. 11. Technical Support CIG offers technical support 24 hours a day, 7 days a week. Use one of the following methods to contact CIG technical assistance center: Hotline: +86 21 8023 300 Email: support@cambridgeig.com 12. Contact Information Hong Kong 25th Floor, Jar dine House, 1 Connaught Place Hong Kong, PRC Phone: +852 2827 1778 Shanghai 5F, 8Building 2388Chen Hang Road Shanghai 201114, China Phone: +86 21 8023 300 USA Cambridge Industries Group Techmart Center 5201 Great AmericaParkway, Suite 320 Santa Clara CA 95054. Tel: +1 408.730.6888 11 13. Legal declaration CIG name, CIG logo, and all CIG product names are trademarks of Cambridge Industries Group Co. Ltd (CIG). All other brand and product names are claimed as property of others respective holders. Specifications, products, and products names are subject to change without notice. Copyright This document may not be reproduced in whole or in part without the express written permission of CIG. This document contains confidential, proprietary information belonging to CIG, and may not be used or disclosed except in accordance with applicable agreements. Performance figures and data quoted in this document are typical and must be specifically confirmed by CIG before they become applicable to any particular order or contract. The company reserves the right to make alterations or amendments to the detailed specification at its discretion. Copyright© 2014, Cambridge Industries Group Co. Ltdconfidential, All rights reserved. 1.1 Connect PoE Adapter to WF-610 Notes: Now WF-610 can be powered by standard 802.3af or 802.3at PoE PSE.Please connect the Ethernet Port labeled “PWR LAN-OUT” on PoE Adapter to “ETH” port of WF-610and the Ethernet Port labeled “LAN-IN” on PoE Adapter to your PC or Switch. 12 1.2 Configure PC’s IP Address Notes: Connect your PC to the “LAN-IN” port on PoE Adapter of WF-610, manually configure your wired NIC with a static IP address on the 192.168.188.x subnet (e.g. 192.168.188.202). 1.3 Visit WF-610 Web Page Notes: Input the default IP address “192.168.188.251”in the address bar of browser. Then enter the 13 default username and password (username: admin, password: password) to enter the Web interface of AP. 1.4 Configure Management Interface for WF-610 Notes: You can configure management IP/subnetmask/gateway/DNS here. By default, packets are sent without tag. Packets can be sent with tag by selecting the option as shown in the figure. 1.5 Connect WF-610 to Switch Notes: Connect WF-610 to Switch and confirm it can visit Internet, then configure your PC to the same subnet and connect to the same Switch in order to continue to configure the WF-610. 14 1.6 Configure Location, Language Notes:The country code is US and can’t be modified. 1.7 Configure Security Profile for Different Authentication Types 1.7.1 WEP WEP-OPEN: 15 WEP-Shared Key: 1.7.2 WPA2-PSK Notes: With parameter “Encryption”, you can select AES, TKIP or AES/TKIP. 1.7.3 WPA/WPA2-PSK Notes: With parameter “Encryption”, you can select AES, TKIP or AES/TKIP. 1.7.4 802.1X /EAP If want to use the 802.1x authentication, it need to configure the Radius profile firstly. Then in the security profile, the radius profile will be cited by security profile. 16 Notes:Security type can be WPA2 or WPA/WPA2. 1.7.5 WEB/MAC WF-610 supports Web/MAC authentication. If you want to use the Web/MAC authentication, it needs to configure the Portal profile and Radius profile firstly. Then in the security profile, the Portal profile and Radius profile will be cited.Above all, you need to setup a portal server and radius server. Notes: MAC and WEB authentication have the same configuration. Afterreceiving auth request from station, WF-610 will firstly start MAC auth. If MAC auth is failed, WF-610 will change to WEB auth. 17 Notes: Wall garden can be configured by inputting custom domain or IP. User can visit these domains or IP listed in wall garden before authentication. For those domains or IP not contained in wall garden, they can be visited only after authentication. 18 2 AP Mode 2.1 AP Network Topology 2.2 Enable AP Mode 19 2.3 Configure Radio Parameters 2.4 Configure SSID 20 Notes: 1. You may apply the Security, Rate Limit or MAC ACL profiles which have been configured. After the above setting, wireless stations can connect to the SSID of AP and get IP address from DHCP server to visit Internet. 2. VLAN mode and PVID used for Ethernet traffic can be configured here. 2.5 Configure Rate Limit Rule (Optional) Notes: Rate Limit profile will be applied in the SSID configuration. 2.6 Configure Group ID (Optional) Notes: Group profile is used for 802.1x/Web/MAC authentication. Group is classifiedby Filter-ID attribute in radius access accept message. The Group is bound with the role of the user. Different group has different VLAN and rate limit configuration. When a station sends the username and password to the Radius server for authentication, the server can respond with a Filter-ID (optional) to the AP. After getting the Filter-ID attribute, AP will search the Filter-ID in the Group profiles. If the 21 Filter-ID can be matched with one profile, the traffic VLAN and rate limit will be applied to the station. The Group profile is applied in the Radius server profile. 22 2.7 Configure MAC ACL Rule (Optional) 2.8 AP+WDS WF-610 also supports AP+WDS mode. 2.8.1 AP+WDS Network Topology 2.8.2 Enable WDS function 23 Note: Enable WDS function when you configure SSID. 2.8.3 Configure CPE WDS Note: Enable WDS function too when you configure CPE to connect to AP. 24 3 WDS Bridge Mode 3.1 WDS Bridge Network Topology 3.2 Enable WDS Bridge Mode Note: Please select a specified Channel (for example 161) here. 3.3 Input Remote AP MAC 25 Note:Security profile can be cited here, but only WEP auth and OPEN are supported for WDS bridge mode. 3.4 Configuration on Remote AP Note: Please select the same channel. For the WDS bridge mode, two APs should use the same channel and security encryption. Note: Please input the MAC address of AP which you want to connect via WDS. 3.5 NAWDS Auto Find WF-610 also supports “NAWDS Auto Find” function. Input the MAC address of the slave AP on the master AP. Then enable “NAWDS Auto Find” function in slave AP without inputting the MAC address. Slave AP configuration: 26 Notes: Please select the same Channel as that of AP which you want to connect via WDS. Notes: After you enable “NAWDS Auto Find” function, the AP will connect to the master AP via WDS automatically. 4 Status 4.1 Overview You can check some summary info here, for example, software version, ip interface and radio configuration. 27 4.2 Radio In this page, you can see service mode for radio 2.4G is AP mode. There is only one SSID “2g_ssid1” with BSSID 00:00:11:11:11:10 and totally two stations are connected to this radio. Information will be updated by clicking “Refresh” button. For radio 5G, you can open “status”-“Radio 5G” to check detailed information. Something to mentioned, detailed information about station (e.g. auth type/MAC/online time/TX bytes/RX bytes) exists in “station list”. 28 5 Management 5.1 Backup/Import Configuration Notes: Press “Save” button to save current configuration. If you want to import one new configuration file, please click “choose file” to select the new file and then press “Upload” button to upload. After that, WF-610 will reboot. 5.2 Software Upgrade Notes: Press “Choose File” button to select firmware file that you want to upgrade, then press “Upgrade” button to upgrade. 5.3 Factory Reset via WEB Click “Restore” button to do factory reset. All of the configuration will be restored to default. 29 5.4 Reboot via WEB 5.5 Factory Reset via Sending Special Packet WF-610 has no reset button. If you forget WF-610’s IP, you can use a simple tool— anysendtcpip to execute factory reset via sending special packet. After that, you can telnet WF-610 with default IP 192.168.188.251. 5.5.1 Factory Reset One Single Device Open file folder. 30 Double click anysend.exe. Click the yellow icon located top left corner,and select . 31 Select right network card which is used to send packet. Modify the MAC address marked in red to beWF-610’s MAC with which you want to do factory reset. 32 Click the yellow icon located top right corner, then it will start to send special broadcast packet. After devices receive the packet, they will check if it matches with their own MAC. If it does, device will execute factory reset. If not, device will do nothing. 5.5.2 Factory Reset All Devices Select and open . Here you can see one special default MAC address marked in red color whichis 00:01:02:03:04:05. You don’t need to modify it. Select the right network card and click the yellow icon to send packet. After devices receive the packet, they won’t check if it matches with their own MAC, and directly execute factory reset. 33 6 Troubleshooting 6.1 Ping Diagnose 6.2 TraceRT Diagnose 34 6.3 LED Definition LEDs are defined as follows: Label Function LED mode RUN AP power / ready Off status Red On - Green LAN Ethernet Network Off Link Status / On - Yellow Activity On - Green (HW Control) Flashing 5G Radio 5G Hz Radio Status Off On – Green 2.4G Radio 2.4G Hz Radio Off Status On – Green 6.4 Debug via Telnet You can debug WF-610 via Telnet. Username: admin Password: password 35 Status No power to AP Device hardware failure Device ready Ethernet link unavailable Link speed 10/100M Link speed 1G Ethernet activity 5G Hz radio disabled 5G Hz radio enabled 2.4G Hz radio disabled 2.4G Hz radio enabled Federal Communications Commission (FCC) Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generate, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. RF exposure warning This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 118.97 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. 36
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 36 Language : zh-CN Tagged PDF : Yes Author : wifi123 Creator : Microsoft® Office Word 2007 Create Date : 2015:08:26 10:24:21 Modify Date : 2015:08:26 10:24:21 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools