CIMCON Lighting CIM35X1 CIMX1PRO RF MODULE User Manual
CIMCON Lighting, Inc. CIMX1PRO RF MODULE
User Manual
RF Module Model: CIMX1PRO Product Manual CIMCON Lighting, Inc. 234 Littleton Road Westford, MA 01886. www.cimconlighting.com Document No. RFM-PM-100-010-A Confidential Product Manual RF Module No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of CIMCON Lighting, Inc. Information in this document is subject to change without notice. CIMCON Lighting, Inc. may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights covering subject matter in this document. The furnishing of this document does not give you license to these patents, trademarks, copyrights, or other intellectual property except as expressly provided in any written license agreement from CIMCON Lighting, Inc. © 2013 CIMCON Lighting, Inc. All rights reserved. This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module Table of Contents 1.1. 1.2. 1.3. 1.4. 4.1. 4.2. 4.3. 4.4. GETTING STARTED ......................................................................................... 1-1 OVERVIEW ................................................................................................................................... 1-1 KEY FEATURES .............................................................................................................................1-1 FCC APPROVALS ......................................................................................................................... 1-2 FCC LABELING REQUIREMENTS .................................................................................................. 1-2 SMT MODULE PIN-OUT.................................................................................. 2-1 THROUGH HOLE MODULE PIN-OUT ............................................................. 3-4 CONFIGURATION INFORMATION ................................................................. 4-1 ABSOLUTE MAXIMUM RATINGS OF RF MODULE........................................................................... 4-1 RECOMMENDED OPERATING CONDITIONS ................................................................................... 4-1 DC ELECTRICAL CHARACTERISTICS.............................................................................................. 4-1 POWER SETTINGS FOR REGULATORY COMPLIANCE ....................................................................... 4-2 BOARD LAYOUT ..............................................................................................5-1 SOLDERING TEMPERATURE PROFILE.......................................................... 6-1 6.1. LEADED PROCESS ........................................................................................................................ 6-1 6.2. LEAD FREE PROCESS ................................................................................................................... 6-1 MECHANICAL DIMENSIONS OF THE SMT MODULES .................................... 7-1 MECHANICAL DIMENSIONS FOR THROUGH HOLE MODULE ...................... 8-1 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module 1.1. GETTING STARTED Overview This manual describes the key features, pin out, recommended operating conditions, working of RF module and operating instructions to test the module for FCC. CIMCON RF modules are designed to operate within the ZigBee protocol and support the unique needs of low-cost, low-power wireless sensor networks. The modules require minimal power and provide reliable delivery of data between remote devices. The modules operate within the ISM 2.4 GHz frequency band work on ZigBee protocol. 1.2. Key Features The key features of RF modules are as follows: • Operates from wide 2.1VDC to 3.6VDC • Maximum transmit current is 150mA (Typical at 3.0V) • Maximum Receive current is 38mA • Maximum transmit power is +22dBm • Receiver Sensitivity of -104dBm • Various serial interfaces like UART, SPI (master/ slave), and TWI • Six external ADC sources with 14-bit resolution • Urban range of ~85m • Line of sight range of ~1750m 1-1 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module 1.3. FCC Approvals The CIMCON SMT module and through hole module with the integrated wire whip Antenna as well as the SMT module and through hole including the 2.1dBi external antenna complies with FCC CFR Part 15 (USA). The devices meet the requirements for modular transmitter approval. External Antennas: Dipole Antenna (P/N: A24-HASM-525; Maximum Antenna Gain: 2.1dBi) Dipole Antenna (P/N: A24-HASM-450; Maximum Antenna Gain: 2.1dBi) This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Changes and Modifications not expressly approved by CIMCON can void your authority to operate this equipment under Federal Communications Commission’s rules. The following statement must be included as a CAUTION statement in manuals for OEM products to alert users on FCC RF exposure compliance: “WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 CM or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operations at closer distances than this are not recommended.” 1.4. FCC Labeling Requirements When integrating the CIMCON’s SMT module or TH module into a product it must be ensured that the FCC labeling requirements are met. This includes a clearly visible label on the outside of the finished product specifying the CIMCON’s FCC identifier (FCC ID: S3Z-CIM35X1) as well as the notice above. This exterior label can use wording such as “Contains Transmitter Module FCC ID: S3Z-CIM35X1” or “Contains FCC ID: S3Z-CIM35X1” although any similar wording that expresses the same meaning may be used. 1-2 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module SMT MODULE PIN-OUT SWCLK, JTCK PB2, SC1MISO, SC1MOSI, SC1SCL, SC1RXD, TIM2C2 PB1, SC1MISO, SC1MOSI, SC1SDA, SC1TXD, TIM2C1 PA6, TIM1C3 PA5, ADC5, PTI_DATA, nBOOTMODE, TRACEDATA3 PA4, ADC4, PTI_EN, TRACEDATA2 PA3, SC2nSSEL, TRACECLK, TIM2C2 PA2, TIM2C4, SC2SCL, SC2SCLK 18 17 16 15 14 13 12 11 Following is the pin out of CIMCON RF module with description of each pin: 19 10 PC2, JTDO, SWO 20 PA1, TIM2C3, SC2SDA, SC2MISO PC3, JTDI 21 PA0, TIM2C1, SC2MOSI PC4, JTMS, SWDIO PC1, ADC3, SWO, TRACEDATA0 22 23 PB4, TIM2C4, SC1nRTS, SC1nSSEL PB3, TIM2C3, SC1nCTS, SC1SCLK PC0, JRST, IRQD, TRACEDATA1 24 PA7, TIM1C4, REG_EN PB7, ADC2, IRQC, TM1C2 25 PC7, OSC32A, OSC32_EXT PB6, ADC1, IRQB, TM1C2 26 PC6, OSC32B, nTX_ACTIVE 27 nRESET 28 VDD_PADS GND PB5, ADC0, TIM2CLK, TIM1MSK VDD_PADS EMBER RF MODULE GND Descriptions: PIN SIGNAL 3.3V nReset PC6 OSC32B nTX_ACTIVE PC7 OSC32A DIRECTION Power I/O I/O I/O I/O DESCRIPTION Used to power the CIMCON RF module. Active Low chip reset (Internal pull up) Digital I/O 32.768 kHz crystal oscillator Inverted TX_ACTIVE signal (see PC5) Digital I/O 32.768 kHz crystal oscillator 2-1 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module PIN 10 11 12 13 14 15 SIGNAL OSC32_EXT PA7 TIM1C4 TIM1C4 REG_EN PB3 TIM2C3 TIM2C3 SC1nCTS SC1SCLK SC1SCLK PB4 TIM2C4 TIM2C4 SC1nRTS SC1nSSEL PA0 TIM2C1 TIM2C1 SC2MOSI SC2MOSI PA1 TIM2C3 TIM2C3 SC2SDA SC2MISO SC2MISO Ground PA2 TIM2C4 TIM2C4 SC2SCL SC2SCLK SC2SCLK PA3 SC2nSSEL TRACECLK TIM2C2 TIM2C2 PA4 ADC4 PTI_EN TRACEDATA2 PA5 ADC5 PTI_DATA nBOOTMODE TRACEDATA3 PA6 TIM1C3 TIM1C3 DIRECTION I/O I/O I/O I/O I/O I/O Power I/O I/O I/O I/O Analog I/O Analog I/O DESCRIPTION Digital 32.768 kHz clock input source Digital I/O Timer 1 Channel 4 output Timer 1 Channel 4 input External regulator open drain output Digital I/O Timer 2 channel 3 output Timer 2 channel 3 input UART CTS handshake of Serial Controller 1 SPI master clock of Serial Controller 1 SPI slave clock of Serial Controller 1 Digital I/O Timer 2 channel 4 output Timer 2 channel 4 input UART RTS handshake of Serial Controller 1 SPI slave select of Serial Controller 1 Digital I/O Timer 2 channel 1 output Timer 2 channel 1 input SPI master data out of Serial Controller 2 SPI slave data in of Serial Controller 2 Digital I/O Timer 2 channel 3 output Timer 2 channel 3 input TWI data of Serial Controller 2 SPI slave data out of Serial Controller 2 SPI master data in of Serial Controller 2 Ground pin of RF module. Digital I/O Timer 2 channel 4 output Timer 2 channel 4 input TWI clock of Serial Controller 2 SPI master clock of Serial Controller 2 SPI slave clock of Serial Controller 2 Digital I/O SPI slave select of Serial Controller 2 Synchronous CPU trace clock Timer 2 channel 2 output Timer 2 channel 2 input Digital I/O ADC Input 4 Frame signal of Packet Trace Interface (PTI) Synchronous CPU trace data bit 2 Digital I/O ADC Input 5 Data signal of Packet Trace Interface (PTI) Embedded serial bootloader activation out of reset Synchronous CPU trace data bit 3 Digital I/O Timer 1 channel 3 output Timer 1 channel 3 input 2-2 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module PIN 16 17 18 19 20 21 22 23 24 25 26 27 28 SIGNAL PB1 SC1MISO SC1MOSI SC1SDA SC1TXD TIM2C1 TIM2C1 PB2 SC1MISO SC1MOSI SC1SCL SC1RXD TIM2C2 TIM2C2 SWCLK JTCK Ground PC2 JTDO SWO DIRECTION I/O I/O I/O I/O I/O Power I/O PC3 JTDI PC4 JTMS SWDIO PC1 ADC3 SWO I/O I/O I/O I/O Analog TRACEDATA0 PC0 JRST IRQD TRACEDATA1 PB7 ADC2 IRQC TIM1C2 TIM1C2 PB6 ADC1 IRQB TIM1C1 TIM1C1 PB5 ADC0 TIM2CLK TIM1MSK 3.3V I/O I/O Analog I/O Analog I/O Analog Power DESCRIPTION Digital I/O SPI slave data out of Serial Controller 1 SPI master data out of Serial Controller 1 TWI data of Serial Controller 1 UART transmit data of Serial Controller 1 Timer 2 channel 1 output Timer 2 channel 1 input Digital I/O SPI master data in of Serial Controller 1 SPI slave data in of Serial Controller 1 TWI clock of Serial Controller 1 UART receive data of Serial Controller 1 Timer 2 channel 2 output Timer 2 channel 2 input Serial Wire clock input/output with debugger JTAG clock input from debugger Ground pin of RF module. Digital I/O JTAG data out to debugger Serial Wire Output asynchronous trace output to debugger Digital I/O JTAG data in from debugger Digital I/O JTAG mode select from debugger Serial Wire bidirectional data to/from debugger Digital I/O ADC Input 3 Serial Wire Output asynchronous trace output to debugger Synchronous CPU trace data bit 0 Digital I/O JTAG reset input from debugger Default external interrupt source D Synchronous CPU trace data bit 1 Digital I/O ADC Input 2 Default external interrupt source C Timer 1 channel 2 output Timer 1 channel 2 input Digital I/O ADC Input 1 External interrupt source B Timer 1 channel 1 output Timer 1 channel 1 input Digital I/O ADC Input 0 Timer 2 external clock input Timer 1 external clock mask input Used to power the CIMCON RF module. 2-3 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module THROUGH HOLE MODULE PINOUT Following is the pin out of CIMCON TH Si Module with description of each pin: Descriptions: PIN SIGNAL 3.3V PB1 SC1MISO SC1MOSI SC1SDA SC1TXD TIM2C1 TIM2C1 PB2 SC1MISO SC1MOSI SC1SCL SC1RXD TIM2C2 TIM2C2 PB5 ADC0 TIM2CLK TIM1MSK PB7 ADC2 IRQC TIM1C2 DIRECTION Power I/O I/O I/O I/O I/O Analog I/O Analog DESCRIPTION Used to power the CIMCON RF module. Digital I/O SPI slave data out of Serial Controller 1 SPI master data out of Serial Controller 1 TWI data of Serial Controller 1 UART transmit data of Serial Controller 1 Timer 2 channel 1 output Timer 2 channel 1 input Digital I/O SPI master data in of Serial Controller 1 SPI slave data in of Serial Controller 1 TWI clock of Serial Controller 1 UART receive data of Serial Controller 1 Timer 2 channel 2 output Timer 2 channel 2 input Digital I/O ADC Input 0 Timer 2 external clock input Timer 1 external clock mask input Digital I/O ADC Input 2 Default external interrupt source C Timer 1 channel 2 output 3-4 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module PIN 10 11 12 13 14 15 16 17 18 19 20 SIGNAL TIM1C2 PC4 JTMS SWDIO PC3 JTDI PC0 JRST IRQD TRACEDATA1 PC1 ADC3 SWO DIRECTION I/O I/O I/O I/O I/O Analog TRACEDATA0 Ground PC2 JTDO SWO Power I/O PB4 TIM2C4 TIM2C4 SC1nRTS SC1nSSEL SWCLK JTCK PA5 ADC5 PTI_DATA nBOOTMODE TRACEDATA3 PC6 OSC32B nTX_ACTIVE PB3 TIM2C3 TIM2C3 SC1nCTS SC1SCLK SC1SCLK PA4 ADC4 PTI_EN TRACEDATA2 nReset NC NC I/O I/O I/O Analog I/O I/O I/O I/O Analog N/A N/A DESCRIPTION Timer 1 channel 2 input Digital I/O JTAG mode select from debugger Serial Wire bidirectional data to/from debugger Digital I/O JTAG data in from debugger Digital I/O JTAG reset input from debugger Default external interrupt source D Synchronous CPU trace data bit 1 Digital I/O ADC Input 3 Serial Wire Output asynchronous trace output to debugger Synchronous CPU trace data bit 0 Ground pin of RF module. Digital I/O JTAG data out to debugger Serial Wire Output asynchronous trace output to debugger Digital I/O Timer 2 channel 4 output Timer 2 channel 4 input UART RTS handshake of Serial Controller 1 SPI slave select of Serial Controller 1 Serial Wire clock input/output with debugger JTAG clock input from debugger Digital I/O ADC Input 5 Data signal of Packet Trace Interface (PTI) Embedded serial bootloader activation out of reset Synchronous CPU trace data bit 3 Digital I/O 32.768 kHz crystal oscillator Inverted TX_ACTIVE signal (see PC5) Digital I/O Timer 2 channel 3 output Timer 2 channel 3 input UART CTS handshake of Serial Controller 1 SPI master clock of Serial Controller 1 SPI slave clock of Serial Controller 1 Digital I/O ADC Input 4 Frame signal of Packet Trace Interface (PTI) Synchronous CPU trace data bit 2 Active Low chip reset (Internal pull up) N/A N/A 3-5 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module CONFIGURATION INFORMATION 4.1. Absolute Maximum Ratings of RF Module The following table provides maximum ratings of RF Module: Sr. No. Parameter Symbol Absolute Maximum ratings -0.3 to +3.6 -0.3 to Vcc+0.3 Unit Supply Voltage Voltage on any GPIO including nReset and JCLK Vcc VIN Voltage on any GPIO [PA4, PA5, PB5, PB6, PB7, PC1] when used as input to ADC Storage Temperature Range Operating Temperature Range ESD on any pin (HBM) ESD on RF port (CDM) Moisture Sensitivity Level (MSL) Reflow Temperature VIN -0.3 to +2.0 VDC Tstg Top Vhbm Vcdm -40 to +105 -40 to +85 +/-2 +/-225 MSL3 Refer in next pages ‘C ‘C KV 4.2. Recommended Operating Conditions Sr. No Parameter Symbol Supply Voltage Operating frequency Operating Temperature Vcc Fin Top 4.3. Treflow VDC VDC Recommended Operating Conditions 2.1 to 3.6 2405 to 24 -40 to +85’C Unit VDC MHz ‘C DC Electrical Characteristics Parameter Voltage supply Low Schmitt switching threshold Test Conditions Input current for logic 0 VSWIL Schmitt input threshold going from high to low VSWIH Schmitt input threshold going from low to high IIL Input current for logic 1 IIH Input pull-up resistor value RIPU High Schmitt switching threshold Min. 2.1 0.42 x VDD_PADS Typical 0.62 x VDD_PADS 24 29 Max 3.6 0.50 x VDD_PADS Unit VDC 0.80 x VDD_PADS -0.5 uA +0.5 uA 34 kΩ 4-1 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module Parameter Input pull-down resistor value Test Conditions RIPD Min. 24 Output voltage for logic VOL (IOL = 4 mA for standard pads, 8 mA for high current pads) VOH (IOH = 4 mA for standard pads, 8 mA for high current pads) IOHS Output voltage for logic Output source current (standard current pad) Typical 29 Max 34 Unit kΩ 0.18 x VDD_PADS 0.82 x VDD_PADS VDD_PADS mA Output sink current (standard current pad) IOLS mA Output source current high current pad: PA6, PA7, PB6, PB7, PC0 IOHH mA Output sink current high current pad: PA6, PA7, PB6, PB7, PC0 IOLH mA Total output current (for I/O Pads) IOH + IOL 40 mA 4.4. Power Settings for Regulatory Compliance Because of the high gain of the frontend module output power of up to 24dBm can be achieved When the antenna gain is included then the output power of the EM357 transceivers needs to be reduced for regulatory compliance. The following tables list the maximum permitted power setting for the different antenna types listed. This is the power out of the EM357 chip, and the power delivered to the antenna will be higher by the gain of the PA. settxpower P (set the channel power) UFL Antenna Unit • • • Channel 11: P = -5 [dBm] Channel 18: P = -5 [dBm] Channel 25: P = -7 [dBm] Fixed Antenna Unit • • • Channel 11: P = -3 [dBm] Channel 18: P = -3 [dBm] Channel 25: P = -3 [dBm] 4-2 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module BOARD LAYOUT CIMCON RF modules do not have any specific sensitivity to nearby processors, crystals or other PCB components. Other than mechanical considerations, no special PCB placement is required for integrating CIMCON RF radios. In general, Power and GND traces should be thicker than signal traces and be able to comfortably support the maximum currents. The radios are also designed to be self-sufficient and work with wire whip and external antennas without the need for additional ground planes on the host PCB. However, considerations should be taken on the choice of antenna and antenna location. Metal objects that are near an antenna cause reflections and may reduce the ability for an antenna to efficiently radiate. Using an integral antenna (like a wire whip antenna) in an enclosed metal box will greatly reduce the range of a radio. For this type of application an external antenna would be a better choice. External antennas should be positioned away from metal objects as much as possible. Metal objects next to the antenna or between transmitting and receiving antennas can often block or reduce the transmission distance. Some objects that are often overlooked are metal poles, metal studs or beams in structures, concrete (it is usually reinforced with metal rods), metal enclosures, vehicles, elevators, ventilation ducts, refrigerators and microwave ovens. The Wire Whip Antenna should be straight and perpendicular to the ground plane and/or chassis. It should reside above or away from any metal objects like batteries, tall electrolytic capacitors or metal enclosures. If the antenna is bent to fit into a tight space, it should be bent so that as much of the antenna as possible is away from metal. Caution should be used when bending the antenna, since this will weaken the solder joint where the antenna connects to the module. Antenna elements radiate perpendicular to the direction they point. Thus a vertical antenna emits across the horizon 5-1 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module SOLDERING TEMPERATURE PROFILE 6.1. Leaded Process 6.2. Lead Free Process 6-1 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module MECHANICAL DIMENSIONS OF THE SMT MODULES 7-1 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted. Product Manual RF Module MECHANICAL DIMENSIONS FOR THROUGH HOLE MODULE 8-1 This information is confidential and proprietary to CSI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CSI is not permitted.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Producer : Acrobat Distiller 5.0 (Windows) Create Date : 2013:03:25 16:02:24Z Modify Date : 2013:03:25 13:42:22-04:00 Metadata Date : 2013:03:25 13:42:22-04:00 Creator Tool : PScript5.dll Version 5.2 Format : application/pdf Creator : sudhanshu Title : Microsoft Word - RF Module Product Manual - 1 0 2.doc Document ID : uuid:7ed9158f-615c-4ebb-a1ea-805f36797ed8 Instance ID : uuid:b6501858-4c4c-4f6a-956a-2e69916546be Page Count : 16 Author : sudhanshuEXIF Metadata provided by EXIF.tools