CNet Technology 0252WLAP 11Mbps Wireless Access Point User Manual Manual

CNet Technology Inc 11Mbps Wireless Access Point Manual

Manual

Download: CNet Technology 0252WLAP 11Mbps Wireless Access Point User Manual Manual
Mirror Download [FCC.gov]CNet Technology 0252WLAP 11Mbps Wireless Access Point User Manual Manual
Document ID295760
Application IDJe1wKRsX6CnfbCY7/3CvIA==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize77.01kB (962685 bits)
Date Submitted2003-01-14 00:00:00
Date Available2003-01-14 00:00:00
Creation Date2003-01-06 10:03:44
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2003-01-14 13:43:30
Document TitleEight (8) ports Gigabit / Fast Ethernet Smart Switch
Document CreatorAcrobat PDFMaker 5.0 for Word
Document Author: user

11Mbps Wireless LAN Access Point
CNAP-711 USER GUIDE
TABLE OF CONTENTS
INTRODUCTION ...............................................................................................................5
1.1
The 11Mbps Wireless Access Point.....................................................................5
1.2
Features ..............................................................................................................5
PACKAGE CONTENTS ....................................................................................................6
ACCESS POINT CONFIGURATION.................................................................................7
3.1
Hardware installation ...........................................................................................7
3.2
Software installation ............................................................................................7
3.3
Configuring the Access Point...............................................................................9
3.4
3.3.1
Connecting to the AP....................................................................................9
3.3.2
FIND AP .....................................................................................................10
3.3.3
Connect AP ................................................................................................10
Configuration .....................................................................................................12
3.4.1
Change Password ......................................................................................15
3.4.2
Encryption (WEP).......................................................................................15
3.4.3
Configure “Advance” (Expert setting) .........................................................19
APPENDIX: ............................................................................................................................23
GLOSSARY............................................................................................................................24
SPECIFICATIONS...........................................................................................................26
INFORMATION TO USER
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, (example - use only shielded interface cables
when connecting to computer or peripheral devices) any changes or modifications not
expressly approved by the party responsible for compliance could void the user's authority to
operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Regulatory
The wireless LAN ACCess Point must be installed and used in strict accordance with the
manufacturer’s instructions. This device complies with the following radio frequency and safety
standards.
USA - Federal Communications Commission (FCC)
This device complies with Part 15 of FCC Rules. Operation is subject to the following two
conditions:
•This device may not cause harmful interference.
•This device must accept any interference that may cause undesired operation.
Europe - R&TTE Directive
This device complies with the specifications listed below:
•ETS 300-826 General EMC requirements for Radio equipment.
•ETS 300-328 Technical requirements for Radio equipment.
•EN60950 Safety requirements for Radio equipment.
EU Countries not intended for use
The ETSI version of this device is intended for home and office use in Austria, Belgium,
Denmark, Finland, France (with Frequency channel restrictions). Germany, Greece, Ireland,
Italy, Luxembourg, Netherlands, Portugal, Spain, Sweden and United Kingdom.
The ETSI version of this device is also authorized for use in EFTA member states Iceland,
Liechtenstein, Norway and Switzerland.
1 Introduction
1.1 The 11Mbps Wireless Access Point
The 11Mbps WLAN Access Point is a long-range, high performance LAN product, which
provides Access Point services to a 2.4 GHz RF network and bridges to an Ethernet backbone.
This solution offers fast, reliable wireless connectivity with considerable cost savings over
wired LANs (which include long-term maintenance overhead for cabling.) Just install enough
wireless access points, plug WLAN card into User notebook or WLAN adapter into User
desktop PC, and start networking.
Using this device in conjunction with WLAN cards or adapters, User can create an instant
network that integrates seamlessly with 10Mbps Ethernet LANs. Moreover, moving or
expanding User network is as easy as moving or installing additional access points - no wire!
1.2 Features
•IEEE 802.11b Direct Sequence spread spectrum high rate compatible.
•High data rate 11/5.5/2/1 Mbps.
•WEP encryption/decryption is accomplished on the fly.
•Fragmentation and Reassembly.
•Wired Equivalent Privacy Algorithm (WEP) (64 bits/128 bits)
•Power Management.
•Passive/Active scan. Long/Short preamble.
•RTS/CTS handshake.
•Duplicate Detection and Recovery.
•Authentication Algorithm (Open System, Shared Key).
•Dual external antennas supporting diversity.
•Easy installation.
2 Package Contents
•One Access Point.
•One setup Utility CD-ROM( User Guide on CD).
•One power adapter.
•Quick Installation Guide.
Quick Installation Guide
3 Access Point Configuration
3.1 Hardware installation
Connect the LAN RJ45 port of the Access Point (AP) to a PC, Notebook or User existing
network (using Ethernet Cat. 5 cable) and connect the DC power adaptor to the AP.
Note: To configure the AP, User can use either the wired Ethernet connection or a Wireless
LAN device.
3.2 Software installation
Insert the setup CD into the CD-ROM drive of the PC or Notebook used for configuration.
There are two methods to install the AP utility software:
(a). Auto run: an auto run program will display on the screen. Click “Install Software”
(b). Alternately, please click “start\run\D:\AP\utility\setup.exe (D:\ is the default letter for the
CD-ROM drive). The InstallShield Wizard will guide User through the installation in the
following menu sequence:
Click “Next”.
Choose the default installation file path and click “Next” or click “Change” to select a
different location.
Click “Install”
Click “Finish” to complete the Software installation.
3.3 Configuring the Access Point
3.3.1
Connecting to the AP
Click Start/Program/SNMP.
Note: The default IP address of the AP is “192.168.0.254”. For connecting to the AP, please
assign an IP address (in the range of 192.168.0.1 ~ 192.168.0.253) to the network device used
for configuration (Wireless or wired LAN card).
The setup program will scan the network for the Access Points installed:
When done, the present settings information of all the Access Points on the network will be
displayed on the screen as below:
There are two “buttons” displayed by the program, “FIND AP” and “Connect AP”. Their
functions are explained below:
3.3.2
FIND AP
Clicking on “FIND AP”, the utility will automatically rescan for all the Access Points (based on
IP address) on the network and display their current settings.
3.3.3
Connect AP
Clicking on “Connect AP”, the utility will connect to the selected AP and an “Input
PASSWORD” dialogue box will be displayed requesting password entry for the AP being
configured:
10
The AP default PASSWORD is “WLAN”, to initially configure the AP, please type the default
password and click ”OK”.
Note: Passwords are case sensitive. Upper/lower case characters, space or any symbol will
affect PASSWORD recognition.
Note: User also can “double click” AP intended for configuration and type the PASSWORD.
To configure AP with already known static IP, please type the IP address to connect to the AP.
11
3.4 Configuration
The configuration information display as below:
12
Reload Default: Click this button will load the Factory’s default values.
Associated Station: Indicating Current Connect AP value
Regulation Domain: Indicating compliance Specification
Firmware Version: Indicating the current firmware version.
WEP: Indicating encryption On/Off
Help: Online Help file.
Select the AP User intend to configure then click “ Configuration” button.
The following menu displays all the configurable parameters and their present settings on the
AP.
13
User could configure the AP by modifying the contents of each parameter in the above
dialogue box. Below is a brief explanation of the Access Point parameters:
Access Point Name: The Access Point can be assigned a name for easy reference here.
SSID:
All wireless devices within the ESS or extended wireless LAN use the SSID. This can be any
alphanumeric value of up to 32 long. Use this to prevent cross communication between two or
more WLAN in one area.
Channel:
There are 11-14 channels available for with the Access Point. All devices communicating with the
device must use the same channel. There may be restrictions on which channel can be used in
some countries. In Canada and the US, the IC and FCC authorize channels 1 - 11 for use.
Note: If there is more than one AP installed in the same place, please separate APs by at least
4 channels, for example Channel 1 to AP1, Channel 6 to AP2, Channel 11 to AP3….
• RTS Threshold:
The RTS Threshold sets an upper threshold at which point the device will issue an RTS packet.
The RTS (Request To Send) packet is used for the purpose of avoiding data collisions on the
wireless LAN. There are several trade offs to consider when setting this parameter. Setting this
parameter to a small value causes RTS packets to be sent more often, consuming more of the
available bandwidth, therefore reducing the apparent throughput of other network packets.
However, the more often RTS packets are sent, the quicker the system can recover from
interference or collisions. Refer to the IEEE 802.11 Standard for more information on the RTS/CTS
mechanism.
IP Configure:
14
User may change any of the IP settings by simply typing in the desired address. Remember that if
User change the IP address of the device to an address that is outside the subnet of the computer
User are using, User will lose access to the SNMP Utility
• IP Address Internet Protocol address of the Access Point.
• Subnet Mask: Four sets of three digits used to logically divide an IP network into
sub-networks.
• Default Gateway: IP address of a gateway device necessary for communication with devices
outside the subnet of the Access Point. If User network is not divided into different subnets, this
can remain blank.
DHCP:
The Access Point can be configured as a DHCP client by choosing Enabled in the DHCP enable
pull-down menu. By default, DHCP support is disabled. If the Access Point is configured as a
DHCP client, it will be necessary to decide what media will be used to transport DHCP information
to the device. By default the Access Point is configured to receive IP settings through the
Ethernet port.
3.4.1
Change Password
User can change administrator password by Clicking on ”Change Password”. Please type new
password and click ”OK”.
Click “Save setting”
3.4.2
Encryption (WEP)
15
Encryption
If an additional measure of security is desired on the wireless network, WEP (Wired Equivalent
Privacy) encryption can be enabled. WEP encrypts each frame transmitted from the wireless
adapter using one of the keys entered in the WEP Privacy field. The Access Point or wireless
adapter will accept only encrypted frames that it can decrypt correctly. Decrypting can take place
only if the receiver has the correct key used by the transmitter.
Click “Encryption (WEP)” and the following menu will pop up:
Create with Passhrass:
Alternatively, a "Passhrass" can be entered which is used as a
"seed” to randomly generate the four keys. If User type a ASCII
code as Passhrass to generate the WEP encryption for User AP,
then other wireless devices connect to User WLAN device should
use the same ASCII to generate the WEP key.
Default Key ID: Default Key ID determines which Key (Key 1 to Key
4) encrypts
• 64BITS: shared key There are four 10 Hex digit encryption keys available if User select
64bit Encryption (WEP)
16
•128BITS: there are four 26 Hex digit encryption keys available if User select 128bit
17
Make sure to Click
to save all changes.
• NOTE: 64 bit WEP is the same as 40 bit WEP!
The lower level of WEP encryption uses a 40 bit (10 character) “secret key” (set by the user),
and a 24 bit “Initialization Vector” (not under user control). The panel allows the entry of four
keys for 64-bit encryption and one set for 128-bit key encryption. Each key must consist of hex
digits, which means that only digits 0-9 and letters A-F are valid entries. The SNMP Utility will not
apply keys that are not entered correctly.
important: At this stage the configuration of the Access Point is complete and AP can be
used for regular functions. The following section will go through some advanced features on
the AP. It is recommended that novice users consult with networking experts before changing
these settings.
18
3.4.3
Configure “Advance” (Expert setting)
Click the “Advance Settings” button and the following dialogue box will pop up. Click “Yes” to
configure AP or “No” to terminate configuration.
When “YES” selected, the Advanced Setting dialog box with two functional buttons will be
displayed on the screen:
MAC Address Filter
Mac address: Unique 48-bit, hard-coded Media Access Control address known as the station
identifier.
Filtering and Access Control
The wireless access point can limit the wireless devices that associate with it and the data packets
that are forwarded through it. Filters can provide a degree of security and improve network
performance by eliminating broadcast/multicast packets from the radio network. The MAC
Address Filter contains the MAC address of every wireless device allowed to associate with the
19
access point. This prevents unauthorized access to network resources.
Click “Save” when finished setting.
Click
save setting to save all changes.
Bridge setting (indoors application only):
Wireless Bridge
Wireless Bridge mode allows two types of connections:
1. WB Point-to-Point: The wireless bridge is configured to communicate with a specific
remote MAC address.
20
2. Wireless Bridge Point to Multipoint: The Wireless Bridge can communicate with any
Wireless Bridge available in the same channel. When Authorization Algorithm (Authorized
MAC Address), is enabled, the Wireless Bridge can communicate with any Wireless Bridge
whose MAC Address exists in the Authorization Table.
Implementing the Bridge function requires three fundamental conditions:
1. Setting to the same channel connection for the Aps (point to multiple Point), please refer to
“channel setting” option.
2. Setting each AP MAC address (point to point mode only).
3. Selecting “point to point” or “point to multipoint” option to define the bridge operation.
21
Note:
• Strongly recommend against using more than 3 APs when selecting “point to
multipoint” mode of operation as this will create adverse effect due to signal fading
and interference.
•When the AP is set to work as a “Wireless Bridge”, it can not serve as an Access Point
for wireless stations at the same time. To connect a new AP to a “bridge AP” user must
either use a “cross-over” cable or a switch between two APs.
When the Bridge Operation mode is selected, click “OK”
Save the settings by Clicking ”Save Setting”
22
Appendix:
•Reset the AP by manual:
If User forget User password or User WLAN Access Point has locked up, User can reset it to
factory defaults by performing the following steps:
1.
2.
3.
4.
5.
Power off the WLAN Access Point.
Push in the reset button located on the back of the WLAN Access Point.
While holding in the button, apply power to the AP.
The Access Point will start to load the default settings.
Wait for about 5 seconds. Release the Push Button, Then the Access Point will restart
with the factory default settings.
23
Glossary
Access Point - An internetworking device that seamlessly connects wired and wireless
networks together.
Ad-Hoc - An Ad-Hoc wireless LAN is a group of computers each with wireless adapters,
connected as an independent wireless LAN.
Authentication Type - Select Open System or Shared Key Authentication Type:
•Open system: With this setting any station in the WLAN can associate with an AP and
receive and transmit data (null authentication).
•Shared Key: With this setting only stations using a shared key encryption identified by
the AP are allowed to associate with it.
•Both: With this setting stations communicate with the AP either with or without data
encryption.
Backbone - The core infrastructure of a network, the portion of the network that transports
information from one central location to another central location. The information then is
off-loaded onto a local system.
Bit - A binary digit. The value - 0 or 1 used in the binary numbering system. Also, the smallest
form of data.
BSS - Stands for Basic Service Set. An Access Point in a BSS is associated with several client
stations.
Domain - A sub-network comprised of a group of clients and servers under the control of one
security database. Dividing LANs into domains improves performance and security.
DSSS - Direct Sequence Spread Spectrum is the most widely known and used spread
spectrum modulation mechanism, owing most of its popularity to its ease of implementation
and high data rates.
Encryption - A security method that applies a specific algorithm to data in order to alter the
data appearance and prevent other devices from reading the information without access right.
ESS - Stands for Extended Service Set. More than one BSS can be configured as an
Extended Service Set. An ESS is basically a roaming domain.
Ethernet - A popular local area data communications network, originally developed by Xerox
Corp. Ethernet operates on 10 Mbps baseband transmission over shielded coaxial cable or
24
over shielded twisted pair copper wire.
Firmware - Code that is written onto read-only memory (ROM) or programmable read-only
memory (PROM). Once firmware has been written into the ROM or PROM, it is retained even
when the device is turned off.
Fragmentation - Breaking a packet into smaller units when transmitting over a network
medium that cannot support the original size of the packet.
Infrastructure - An integrated wireless and wired LAN is called an infrastructure configuration.
IRQ - Interrupt Request, a hardware interrupt on a PC. There are 16 IRQ lines used to signal
the CPU that peripheral event has started or terminated. In most cases, two devices cannot
use the same interrupt line.
PCMCIA - Personal Computer Memory Card International Association, which develops
standards for PC cards, formerly known as PCMCIA cards, are available in three types which
are about the same length and width as credit cards, but range in thickness from 3.3mm(Type
I), 5.0mm(Type II), to 10.5mm(Type III). These cards can be used for many functions, including
memory storage, as modem cards, wireless LAN cards or Wired LAN cards.
Roaming - A function that allows one to travel with a mobile end system (wireless LAN mobile
station, for example) through the territory of domain(an ESS, for example) while continuously
connecting to the infrastructure.
25
4 Specifications
IEEE 802.11 DS 11Mbps Access Point
LAN Standard
IEEE 802.3 for 10BASE-T
Protocol
Wireless clients IEEE 802.11b
Frequency Band
2400 ~ 2483.5MHz ( for US, Canada, and ETSI)
2400 ~ 2497MHz (for Japan)
Modulation TYPE
CCK,BPSK,QPSK
Operating Channels
IEEE 802.11 compliant
11 channels (US, Canada)
13 channels (ETSI)
14 channels (Japan)
Radio Technology
Direct Sequence Spread Spectrum
Data Rate
1 / 2 / 5.5 / 11 Mbps per Channel
Output Power
+18dBm +/- 2dBm
Receive sensitivity
Min. -80dBm for 11Mbps (@10E-5 BER) -81
Min. -82dBm for 5.5/2/1 Mbps (@10E-5 BER) -85
Wired interface
Ethernet IEEE 802.3 10BASE-T
LEDs
Power, Link Status
Antenna Type
Dipoles antenna
Power Supply
Input: 100~120V, 220~240V AC, 50~60Hz
Output: 5V DC, 2.1A
Power Consumption
Tx Power consumption: < 700mA (Max.) <600mA
Rx Power consumption: < 580mA (Max.) <560mA
Dimensions
85mm x 28mm x 145mm
3.35 x 1.22 x 5.71 inch
Certification
Radio:
EU: ETS 300 328; USA: FCC Part 15C
Taiwan: DGT
EMC:
EU ETS 300 826; USA: FCC Part 15B
Safety: EN60950
Network Management Windows 95/98/NT/2000/XP SNMP Utility
26

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Copy, Fill forms, Extract, Assemble, Print high-res
Modify Date                     : 2003:01:14 13:43:30+08:00
Create Date                     : 2003:01:06 10:03:44+08:00
Page Count                      : 26
Creation Date                   : 2003:01:06 10:03:44+08:00
Mod Date                        : 2014:01:06 17:21:08+08:00
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : user
Metadata Date                   : 2014:01:06 17:21:08+08:00
Creator                         : user
Title                           : Eight (8) ports Gigabit / Fast Ethernet Smart Switch
Page Mode                       : UseNone
Tagged PDF                      : Yes
EXIF Metadata provided by EXIF.tools
FCC ID Filing: IIO-0252WLAP

Navigation menu