EB12B EB12B COLEMAN EVCON FURNACE/HEATER, ELECTRIC - Manuals and Guides L0611517 View the owners manual for your COLEMAN EVCON FURNACE/HEATER, ELECTRIC #EB12B. Home:COLEMAN EVCON:/ Furnace Parts:COLEMAN EVCON furnace parts:#EB12B COLEMAN EVCON furnace parts:#EB12B COLEMAN EVCON furnace/heater, electric manual

User Manual: COLEMAN COLEMAN / EVCON IND. Furnace/Heater, Electric Manual COLEMAN / EVCON IND. Furnace/Heater, Electric Owner's Manual, COLEMAN / EVCON IND. Furnace/Heater, Electric installation guides

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadCOLEMAN  / EVCON IND. Furnace/Heater, Electric Manual L0611517
Open PDF In BrowserView PDF
OWNER'S

MANUAL

EB SERIES
ELECTRIC
FURNACES

I_WARNING
FOR YOUR SAFETY - Do not store or use gasoline or other
flammable
vapors and liquids in the vicinity of this or any
other appliance.
For personal safety be sure to turn the electrical power OFF at
the household service box and at the furnace before attempting any service
or maintenance
operations.
Homeowner
should never perform any maintenance which requires opening the furnace electrical panel.
Do not store or use gasoline or other flammable
vapors
liquids in the vicinity of this or any other appliance.

and

CAUTION
This furnace and its components,
including the air conditioning coils and blowers listed on the A/C accessory
sticker
were listed in combination as a system by Underwriters
Laboratories.
Use of other components
not tested in combination with this
furnace may make the equipment in violation of State Codes,
may create a hazard, and may ruin the equipment.
In addition, the National Manufactured
Housing Construction
and Safety Standards Act and its Regulations
require the use
of components
listed or certified by a nationally recognized
testing laboratory in all manufactured
homes built and sold
subject to that act.
035-15267-002

Rev. B (0304)

035-15267-002
Rev.B(0304)

Congratulations...
On yourpurchase

of one of the most verd'atileJhrnaces

available

in the indusn3* tod_Lv. This compact,

enec_y-eJJicientJhrnace

has been precision designed, manuJbctured
of h_@-quality materials and has passed malty rigoroud' indpections and ted'ts to
ensure malty years of sati_f!_ctol3_ service. This booklet is meant to increase your understanding
of your unit, tell you how to
operate it efficiently and how to obtain the greatest measure of comJbrt at the lowest operating e._7_ense. Please read this booklet thoroughly.

J4@appreciate

your interest

INTRODUCTION

AWARNING
To avoid the possibility of
electrical
shock
do not
open
els.

electrical

TO OPERATE
1.

2.
3.

box

pan-

FURNACE

in our product

and your decision

The interlock system usually contains a heat-cool switch which
must be turned to either HEAT or
COOL to activate either heating or
cooling operation.
If an interlock system has not been
provided, the electrical supply to
the furnace must be turned OFF at
the household service box, when
the air conditioner is being used.
When operating the furnace, the
electrical supply to the air conditioner must be turned OFE

Be sure electrical power to furnace is turned on at the household service box.

TO SHUT FURNACE

Set wall thermostat to the

1.

desired temperature.
If furnace is equipped with Air
Conditioning, the System
Switch, located at the wall thermostat, must be turned to
HEAT in order for the furnace
to operate in the heating mode.

WARNING
If you have an air conditioner which does not
use the furnace blower
for air distribution and
operates
completely
independent of the furnace,
the
thermostat
system must have an
interlock to prevent the
furnace and air conditioner from operating at
the same time. Such
operation could cause
equipment
damage,
energy waste and overheating of the home.

to purchase

OFF

Turn thermostat to its lowest
setting.

NOTE: Furnace will still operate if
room temperature falls below thermostat setting.
2.

For complete shut-down turn
off electrical power at the
household service box.

ourJhrnace.

Enjoy your col_[brt.

LIMIT CONTROLS
Each element has an automatic
limit switch which is wired into the
circuit and shuts off power to that
element if the heat at that point
exceeds the allowable maximum
heat.

BLOWER

REMOVAL

NOTE: Only authorized service
technicians should remove the
blower.
To remove blower from furnace,
turn off power at household service
box, turn furnace circuit breakers
OFF. Disconnect wiring to blower,
and remove five (5) screws holding
blower in furnace and slide blower
out from front of the furnace. See
Figure 1.
Re-install blower in reverse order
when assembling back into furRace.

SEQUENCE OF
OPERATION
When room thermostat calls for
heat, 24-volt power is supplied to
the heating element switches. As
soon as the first heating element
switch closes, the blower starts
and power is supplied to the first
heating element. Each additional
element is staged on in successive intervals.

FILTER (IN
DOWNFLOW
ONLY) *

CAVITY
COIL

,!
_

When the room thermostat is satisfied and no more heat is required,
the elements sequence off in the
reverse order and the blower will
then turn off.

_
.4 _

THERMOSTAT
CIRCUIT
ELECTRIC
PANEL
FIELD WIRING
SHIELD

* Filter in the front panel when Iouvered
doors
are used. Filter iocated in base for upflow units.

FIGURE 1

2

Unitary Products Group

035-15267-002

FURNACE
CIRCUIT

OPERATION

BREAKERS

Your electric furnace is equipped
with a unique safety feature - circuit breakers. These circuit breakers are located behind the door of
the furnace, near the bottom of the
furnace. See Fig. 1. tf a component should fail inside the furnace,
the circuit breakers will prevent
damage that can be caused by an
electrical short. If the breakers
ever trip, they can be reset by first
turning off the power to the furnace
at the home's circuit breaker panel.
See Warning below. Then remove
the furnace door and reset the circuit breaker in the furnace. Reinstall the furnace door and turn
the power back on at the home's
breaker panel. If for some reason
these circuit breakers should trip
again, a service technician should
be contacted as a problem exists
inside the furnace. A list of authorized service centers is provided
with every furnace and will assist
you in obtaining service for your
furnace.

AWARNINGI
You must first de-energize the furnace at the
main household power
supply and lock it.

LUBRICATION
The blower motor bearings are factory sealed. Additional lubrication
is not required.

Unitary Products Group

BLOWER

ASSEMBLY

Every
electric
furnace
comes
equipped with a blower capable of
operating a heat pump or air conditioner. With the addition of the
proper heat pump, you can enjoy
comfort and savings all year long.
An air conditioner will also work
with your furnace and will provide
cool summer days, at a very low
operating cost.

AIR FILTER
The filter supplied with the furnace
is of the throw-away type. Filters
need to be cleaned frequently.
Shake out all loose dirt, and use
vacuum cleaner to clean additionally. This method of cleaning will
prolong life of filters. DO change
filters often since clean filters not
only provide added comfort, better
and cleaner
environment,
but
increase the efficiency of the furnace as well.
FILTER LOCATION: The furnace's
front panel must be removed to
gain access to the filter of the
downflow furnace. (See Figure 1.)
However, the filter for the upflow
furnace* is located behind the
return air grill, adjacent to the furnace closet or any other location in
the return air.

RETURN

AIR

Return air must be provided back
to the circulating blower in order to
provide air distribution. DO NOT
OBSTRUCT ANY RETURN AIR
GRILLE. To do so will cause the
furnace heating elements to cycle
off and on repeatedly.

Rev. B (0304)

IMPORTANT:

WHILE

YOU'RE

AWAY

The power supply to your furnace
is equipped with either a fused or
breaker type disconnect. In case of
an overload, this will interrupt the
operation of your furnace until it is
reset or fuse replaced. For this
reason it is never practical to
assume that the furnace will operate unattended for long periods of
time, especially if there is a possibility of damage to your property
because of freezing. So, if you
plan to be away, arrange for someone to check your home every day
or so.

AT THE BEGINNING OF
EACH HEATING SEASON
NOTE: Be sure electrical supply to
furnace is turned off at the household service box and furnace circuit
breakers before cleaning.
1.

Replace filters as discussed
previously. Clean dust and lint
from in and around the furnace. Clean dust and lint from
blower and blower compartment.

2.

If furnace fails to operate properly:
a.Be sure electrical power is
being supplied to furnace.
Check main household
power supply.
b.lf, after following this procedure, the furnace still fails to
operate, shut off furnace and
contact your service technician.

3

YOUR AUTHORIZED
SERVICE TECHNICIAN

[AWARNINGI

Your furnace's best friend is your
service technician. If the unit gives
any indication of improper operation, call your authorized service
technician, tf the service technician
is allowed to perform the normal
routine care of your furnace, he
many times can detect potential
difficulties and make corrections
before trouble develops. Preventive maintenance of this type will
allow you to operate this unit with a
minimum of concern and, at the
same time, pay for itself in added
years of comfort.

NOTE: If the controls are located
at the top of the unit, the furnace is
an upflow furnace and the airflow is
forced up through the furnace and
into the airways.

OPTIONAL
AIR CONDITIONING
ACCESSORIES

HIGH PERFORMANCE
BLOWER ACCESSORY
PACKAGE

This furnace is already equipped
with a blower and control system
to add-on air conditioning up to 4
tons and heat pump up to 3-1/2
tons. Insulation and coil shelf kit
(3500-8941 for downflow or 35008961/A
for upflow)
must
be
installed when adding on such
remote air conditioning systems.

All
EB furnaces
are already
equipped with a blower and control system to add-on air conditioning up to 4-tons and heat pump up
to 3 1/2-tons. If the requirement is
to achieve more than specified
than the production blower inside
the furnace would have to be
replaced with an accessory blower
package 3500-7901". This acces-

Failure to install this
insulation and coil shelf
kit could result in damage to equipment and/or
personal injury. Liability
and warranty from the
manufacturer could also
be void.

Subject to change without notice. Printed in U.S.A.
Copyright t_ by York International Corp. 2004. All rights reserved.

Unitary
Products
Group

sory blower package would deliver
air conditioning up to 5-tons, and
heat pump up to 4-tons. Accessory
package
(3500-7901")
includes blower, insulation, coil
shelf, trap, clamps, etc. Please
refer to the installation instructions
packed with the accessory package for more information.

CAUTION
All areas around the fine
sets, drain hoses and
other openings in the furnace should be sealed
airtight. Use some moldable compound or caulking to seal the area.
Failure to do so may
result in loss of performance and premature
compressor failure.

Supersedes:

RO.
Box
19014

035-15267-002
035-!5267-002

Rev. B (0304)
Rev. A (1000)

Wichita
KS
67204-9014



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 4
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Thu Apr 05 07:53:48 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu