COLEMAN / EVCON IND. Furnace/Heater, Electric Manual L0611517
EB12B EB12B COLEMAN EVCON FURNACE/HEATER, ELECTRIC - Manuals and Guides L0611517 View the owners manual for your COLEMAN EVCON FURNACE/HEATER, ELECTRIC #EB12B. Home:COLEMAN EVCON:/ Furnace Parts:COLEMAN EVCON furnace parts:#EB12B COLEMAN EVCON furnace parts:#EB12B COLEMAN EVCON furnace/heater, electric manual
User Manual: COLEMAN COLEMAN / EVCON IND. Furnace/Heater, Electric Manual COLEMAN / EVCON IND. Furnace/Heater, Electric Owner's Manual, COLEMAN / EVCON IND. Furnace/Heater, Electric installation guides
Open the PDF directly: View PDF .
Page Count: 4
OWNER'S MANUAL
EB SERIES
ELECTRIC
FURNACES
I_WARNING
FOR YOUR SAFETY - Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any
other appliance.
For personal safety be sure to turn the electrical power OFF at
the household service box and at the furnace before attempt-
ing any service or maintenance operations. Homeowner
should never perform any maintenance which requires open-
ing the furnace electrical panel.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
CAUTION
This furnace and its components, including the air condition-
ing coils and blowers listed on the A/C accessory sticker
were listed in combination as a system by Underwriters Labo-
ratories.
Use of other components not tested in combination with this
furnace may make the equipment in violation of State Codes,
may create a hazard, and may ruin the equipment.
In addition, the National Manufactured Housing Construction
and Safety Standards Act and its Regulations require the use
of components listed or certified by a nationally recognized
testing laboratory in all manufactured homes built and sold
subject to that act.
035-15267-002 Rev. B (0304)
035-15267-002Rev.B(0304)
Congratulations...
On yourpurchase of one of the most verd'atileJhrnaces available in the indusn3* tod_Lv. This compact, enec_y-eJJicientJhrnace
has been precision designed, manuJbctured of h_@-quality materials and has passed malty rigoroud' indpections and ted'ts to
ensure malty years of sati_f!_ctol3_ service. This booklet is meant to increase your understanding of your unit, tell you how to
operate it efficiently and how to obtain the greatest measure of comJbrt at the lowest operating e._7_ense. Please read this book-
let thoroughly. J4@appreciate your interest in our product and your decision to purchase ourJhrnace. Enjoy your col_[brt.
INTRODUCTION
AWARNING
To avoid the possibility of
electrical shock do not
open electrical box pan-
els.
TO OPERATE FURNACE
1. Be sure electrical power to fur-
nace is turned on at the house-
hold service box.
2. Set wall thermostat to the
desired temperature.
3. If furnace is equipped with Air
Conditioning, the System
Switch, located at the wall ther-
mostat, must be turned to
HEAT in order for the furnace
to operate in the heating mode.
WARNING
If you have an air condi-
tioner which does not
use the furnace blower
for air distribution and
operates completely
independent of the fur-
nace, the thermostat
system must have an
interlock to prevent the
furnace and air condi-
tioner from operating at
the same time. Such
operation could cause
equipment damage,
energy waste and over-
heating of the home.
The interlock system usually con-
tains a heat-cool switch which
must be turned to either HEAT or
COOL to activate either heating or
cooling operation.
If an interlock system has not been
provided, the electrical supply to
the furnace must be turned OFF at
the household service box, when
the air conditioner is being used.
When operating the furnace, the
electrical supply to the air condi-
tioner must be turned OFE
TO SHUT FURNACE OFF
1. Turn thermostat to its lowest
setting.
NOTE: Furnace will still operate if
room temperature falls below ther-
mostat setting.
2. For complete shut-down turn
off electrical power at the
household service box.
SEQUENCE OF
OPERATION
When room thermostat calls for
heat, 24-volt power is supplied to
the heating element switches. As
soon as the first heating element
switch closes, the blower starts
and power is supplied to the first
heating element. Each additional
element is staged on in succes-
sive intervals.
When the room thermostat is satis-
fied and no more heat is required,
the elements sequence off in the
reverse order and the blower will
then turn off.
LIMIT CONTROLS
Each element has an automatic
limit switch which is wired into the
circuit and shuts off power to that
element if the heat at that point
exceeds the allowable maximum
heat.
BLOWER REMOVAL
NOTE: Only authorized service
technicians should remove the
blower.
To remove blower from furnace,
turn off power at household service
box, turn furnace circuit breakers
OFF. Disconnect wiring to blower,
and remove five (5) screws holding
blower in furnace and slide blower
out from front of the furnace. See
Figure 1.
Re-install blower in reverse order
when assembling back into fur-
Race.
FILTER (IN
DOWNFLOW
ONLY) *
CAVITY
COIL
,! THERMOSTAT
_ CIRCUIT
_ ELECTRIC
PANEL
.4 _FIELD WIRING
SHIELD
* Filter in the front panel when Iouvered doors
are used. Filter iocated in base for upflow units.
FIGURE 1
2 Unitary Products Group
035-15267-002 Rev. B (0304)
FURNACE OPERATION
CIRCUIT BREAKERS
Your electric furnace is equipped
with a unique safety feature -cir-
cuit breakers. These circuit break-
ers are located behind the door of
the furnace, near the bottom of the
furnace. See Fig. 1. tf a compo-
nent should fail inside the furnace,
the circuit breakers will prevent
damage that can be caused by an
electrical short. If the breakers
ever trip, they can be reset by first
turning off the power to the furnace
at the home's circuit breaker panel.
See Warning below. Then remove
the furnace door and reset the cir-
cuit breaker in the furnace. Re-
install the furnace door and turn
the power back on at the home's
breaker panel. If for some reason
these circuit breakers should trip
again, a service technician should
be contacted as a problem exists
inside the furnace. A list of autho-
rized service centers is provided
with every furnace and will assist
you in obtaining service for your
furnace.
AWARNINGI
You must first de-ener-
gize the furnace at the
main household power
supply and lock it.
LUBRICATION
The blower motor bearings are fac-
tory sealed. Additional lubrication
is not required.
BLOWER ASSEMBLY
Every electric furnace comes
equipped with a blower capable of
operating a heat pump or air condi-
tioner. With the addition of the
proper heat pump, you can enjoy
comfort and savings all year long.
An air conditioner will also work
with your furnace and will provide
cool summer days, at a very low
operating cost.
AIR FILTER
The filter supplied with the furnace
is of the throw-away type. Filters
need to be cleaned frequently.
Shake out all loose dirt, and use
vacuum cleaner to clean addition-
ally. This method of cleaning will
prolong life of filters. DO change
filters often since clean filters not
only provide added comfort, better
and cleaner environment, but
increase the efficiency of the fur-
nace as well.
FILTER LOCATION: The furnace's
front panel must be removed to
gain access to the filter of the
downflow furnace. (See Figure 1.)
However, the filter for the upflow
furnace* is located behind the
return air grill, adjacent to the fur-
nace closet or any other location in
the return air.
RETURN AIR
Return air must be provided back
to the circulating blower in order to
provide air distribution. DO NOT
OBSTRUCT ANY RETURN AIR
GRILLE. To do so will cause the
furnace heating elements to cycle
off and on repeatedly.
IMPORTANT:
WHILE YOU'RE AWAY
The power supply to your furnace
is equipped with either a fused or
breaker type disconnect. In case of
an overload, this will interrupt the
operation of your furnace until it is
reset or fuse replaced. For this
reason it is never practical to
assume that the furnace will oper-
ate unattended for long periods of
time, especially if there is a possi-
bility of damage to your property
because of freezing. So, if you
plan to be away, arrange for some-
one to check your home every day
or so.
AT THE BEGINNING OF
EACH HEATING SEASON
NOTE: Be sure electrical supply to
furnace is turned off at the house-
hold service box and furnace circuit
breakers before cleaning.
1. Replace filters as discussed
previously. Clean dust and lint
from in and around the fur-
nace. Clean dust and lint from
blower and blower compart-
ment.
2. If furnace fails to operate prop-
erly:
a.Be sure electrical power is
being supplied to furnace.
Check main household
power supply.
b.lf, after following this proce-
dure, the furnace still fails to
operate, shut off furnace and
contact your service techni-
cian.
Unitary Products Group 3
YOUR AUTHORIZED
SERVICE TECHNICIAN
Your furnace's best friend is your
service technician. If the unit gives
any indication of improper opera-
tion, call your authorized service
technician, tf the service technician
is allowed to perform the normal
routine care of your furnace, he
many times can detect potential
difficulties and make corrections
before trouble develops. Preven-
tive maintenance of this type will
allow you to operate this unit with a
minimum of concern and, at the
same time, pay for itself in added
years of comfort.
OPTIONAL
AIR CONDITIONING
ACCESSORIES
This furnace is already equipped
with a blower and control system
to add-on air conditioning up to 4
tons and heat pump up to 3-1/2
tons. Insulation and coil shelf kit
(3500-8941 for downflow or 3500-
8961/A for upflow) must be
installed when adding on such
remote air conditioning systems.
[AWARNINGI
Failure to install this
insulation and coil shelf
kit could result in dam-
age to equipment and/or
personal injury. Liability
and warranty from the
manufacturer could also
be void.
NOTE: If the controls are located
at the top of the unit, the furnace is
an upflow furnace and the airflow is
forced up through the furnace and
into the airways.
HIGH PERFORMANCE
BLOWER ACCESSORY
PACKAGE
All EB furnaces are already
equipped with a blower and con-
trol system to add-on air condition-
ing up to 4-tons and heat pump up
to 3 1/2-tons. If the requirement is
to achieve more than specified
than the production blower inside
the furnace would have to be
replaced with an accessory blower
package 3500-7901". This acces-
sory blower package would deliver
air conditioning up to 5-tons, and
heat pump up to 4-tons. Acces-
sory package (3500-7901")
includes blower, insulation, coil
shelf, trap, clamps, etc. Please
refer to the installation instructions
packed with the accessory pack-
age for more information.
CAUTION
All areas around the fine
sets, drain hoses and
other openings in the fur-
nace should be sealed
airtight. Use some mold-
able compound or caulk-
ing to seal the area.
Failure to do so may
result in loss of perfor-
mance and premature
compressor failure.
Subject to change without notice. Printed in U.S.A.
Copyright t_ by York International Corp. 2004. All rights reserved.
Unitary
Products
Group
RO.
Box
19014
035-15267-002 Rev. B (0304)
Supersedes: 035-!5267-002 Rev. A (1000)
Wichita
KS
67204-9014