User Manual
User Manual COMMAX LOBBY PHONE DRC-703S • • Thank Thank you you for for purchasing purchasing COMMAX COMMAXproducts. products. • • Please Please carefully carefully read read this this User’s User’sGuide Guide(in (inparticular, particular,precautions precautionsfor forsafety) safety)before beforeusing usingaaproduct productand andfollow follow instructions instructions to to use use aa product product exactly. exactly. • • The The company company isis not not responsible responsible for forany anysafety safetyaccidents accidentscaused causedby byabnormal abnormaloperation operationof ofthe theproduct. product. Greetings ● Thank you for choosing COMMAX. ● Please read this manual carefully before you use the product. Table of contents Greetings ..................................................................................................................1 Contents table ...........................................................................................................1 1. Warnings and caution ...........................................................................................2 2. Part names............................................................................................................4 3. Main Screen Setting..............................................................................................5 4. Security Call ..........................................................................................................6 5. Call house .............................................................................................................7 6. Access authorization .............................................................................................9 7. Set up..................................................................................................................11 8. Wiring Diagram ...................................................................................................15 1. Warnings and caution Please follow the things described below in order to prevent any danger or property damage. Warning Prohibition. It may cause a serious damage or injury if violated. No disassembly No touch Caution Must follow strictly. Shows plugging out the power cord without an exception It may cause a minor damage or injury if violated. Shows the warning and caution for an electric shock. Shows the warning and caution for a fire. Power & Installation Warning Please don’t use several products at the same time on one power socket. ·It may cause a fire due to an abnormal overheating. Please don’t bend the power cable excessively or it may cause an electric shock. ·fire when using a damaged power cable. Please don’t handle the power cable with a wet hand. ·It may cause an electric shock. Please plug out the power cable from the socket when not using it for a long period of time. ·It may shorten the product lifespan or cause a fire. Please don’t install the product in the place where there is much oil, smoke or humidity. ·It may cause an electric shock or fire. Please don’t install the product with the lightening and thunder. ·It may cause an electric shock or fire. Please don’t use and connect this product with other products with different rated voltage ·It may cause a disorder or fire. When installing the product that generates heat, please install the product away from the wall (10cm) for the ventilation. ·It may cause a fire due to the increased internal temperature. Cleaning & Use Warning Please don’t disassemble, repair or rebuild this product arbitrarily (please contact the service center if a repair is needed. ·It may cause an electric shock or fire. If an abnormal sound, burning smell or smoke is coming out of the product, please plug out the power cable and contact a service center. ·It may cause an electric shock or fire. Please don’t insert any metallic or burnable materials into the ventilation hole. ·It may cause an electric shock or fire. Please use only the designated batteries for the products of using DC power. ·It may cause an electric shock or fire. Cleaning & Use Power & Installation Caution Please plug the power cable firmly into the inner end ·It may cause a fire. Please hold the plug tightly when unplugging the power cable (a part of the copper wire may be disconnected if the grabbing is only made on the cord when pulling out the cable). ·It may cause an electric shock or fire When connecting the power cables after cutting the cable, please install the product with power off ·It may cause an electric shock or fire Please be careful when using an AC circuit breaker since there is a possibility of an electric shock. Please check the use voltage and current for the DC-only products and use the appropriate rectifier. ·It may cause a fire. Please avoid direct rays of the sun or heating devices at a time of installation. ·It may cause a fire. When cleaning the product, please rub it with a soft and dry cloth after plugging out the power cable. (Please don’t use any chemical products such as wax, benzene, alcohol or cleanser.) Please don’t drop the product on the ground and don’t apply a shock . ·It may cause a failure. Please use the designated connection cable within the maximum calling distance designated for the product ·It may reduce the product performance. When installing the product, please fix it firmly while using the wall-mounting unit and screws. ·It may cause an injury from the falling object. Please don’t install the product on an unstable place or small support board. ·It may cause an injury if it falls down while in use. 2. Part names ① Camera ⑪ Program Button ② LCD ⑫ Cancel Button ③ RF CARD Receiver ⑬ Speaker ④ Mike ⑭ Reset ⑤ LED ⑮ Camera Adjustment Part ⑥ Number Key Button ⑯ DC 14V ⑦ Electric Key Button(in case of input the password) ⑰ RS-485/Zigbee ⑧ Proximity IR Sensor ⑱ Switch Connection (NO,NC) ⑨ Security Button ⑲ LAN PORT ⑩ Call Button 3. Main Screen Setting ● Main ● Screen Status Icon Description Icon Description Lan Connection Registered server status Display out post lobby phone Not Registered server status Display building lobby phone Local Server connection status Display Video Codec(MPEG-4) Display Video Codec(H.264) RF Card Data save status 4. Security Call ① Push (Security Guard Post) Button ② Push (Call) button ③ Call sound is ringing and call Security Guard Post. ④ Call Security Guard Post when guard answer call. (Time: 1 min.) ⑤ Press "X" button when terminate call. ⑥ Security Guard push 'Open door’ button, 'Door is open” voice comment then door is open. ⑦ If line is busy, call it later. Picture1. Call security Guard This is to call up the registered guard stations in advance by a manager 5. Call house ● Communication call between residence When building number is set in advance : When building No. already registered to Call Prefix Picture2. Screen for registering house No. ① Input unit No. to key board. Ex) Unit 101 input ‘101’ ② Push (call) button. ③ Ringing call sound and call unit. ④ When tenants answer call, calling is on. (Max. time: 1 min) ⑤ Press "X" button when terminate call. ⑥ Tenant push 'Open door’ button, "Door is open” voice comment then door is open When building number is NOT set in advance : When building number hasn't been registered Call Prefix yet. Picture3. Building house No. register screen ① Input Building No. to key board. Ex) Building 101 input ‘101’ ② Input unit No. to key board. Ex) Unit 101 input ‘101’ ③ Push (call) button. ④ Ringing call sound and call unit. ⑤ When tenants answer call, calling is on. (Max. time: 1 min) ⑥ Press "X" button when terminate call. ⑦ Tenant push 'Open door’ button, "Door is open” voice comment then door is open 6. Access authorization ● Opening the entrance with RF card. ① Tag RF card to 'Card tagging window’. ② The common entrance get be opened with a vocal message, "Door opens” when the access is successful. ③ The entrance does not be opened when the access fails with sound. Picture4. Tag RF-Card ● Access by PIN No. Building Number designated case : Building Number designated in Call Prefix ① Input unit No. through key board. ② Push (Key) button. ③ Input designated house PIN No. ④ Push (call) button. ⑤ If access authorization is successful, Door is open with "Door is open” voice message. ⑥ If access is failed, warning sound is activated. Building Number is not designated case : Building Number is not designated in Call Prefix ① Input Building No. through key board. EX) Building 101 Input 101 ② Push (call) button. ③ Input unit No. through key board. Ex) Unit 101 Input 101 ④ Push (call) button. ⑤ If access authorization is successful, Door is open with "Door is open” voice message. ⑥ If access is failed, warning sound is activated. Picture5. Input password (PIN) ● Use password for accessing when system is OFF-Line (No connection with Local server) ① Push (Key) button. ② Input PIN number. ③ Push (call) button. Please, should delete OFF-LINE PIN number when On-Line mode is activated ● Use password for accessing when system is ON-Line (When connected with Local server) ① Push (Key) button. ② Input Administration Pin number ③ Push 10 (call) button. 7. Set up ● Set up button. 1 2 1. Push 2. Input PIN number. 4 5 3. Push 6 (call) button. 7 8 We 9 recommend user change initial password (0000) then use products for security. Initialize password : 1 2+“0000” 3 + 1+ 2+ 3 + + button map 4 5 64 5 6 4 5 6 7 8 97 8 9 7 8 9 홈버튼 홈버튼 외출/방범 버튼/LED 외출/방범 버튼/LED 홈버튼 외출/방범 버튼/LED ● “●”is DOT (.) for IP address typing. ● Set up menu 0 : Set Network+ 0 : IP address: (Input IP address) 1 : G/W address (Input Gateway address) 2 : DNS address (Input DNS address) 3 : Net mask (Input network mask) 1 : Set VoIP+ 0 : SIP Server (Input SIP server address) 1 : Guard ID (Input Security Guard Post) 11 2 : Management+ 0 : Server address (Input Local server address) 1 : Update address (Input update server address) 2 : System ID (Input DRC-700S serial No.) 3 : Call Prefix (Set building) If there is no building information in set up, automatically pop up for building information when call house. 4 : Call Line+ 0 : Min Call Line (Input call Min. line) 1 : Max Call Line (Input call Max. line) Attention : If Min Call Line is bigger than Max Call Line, you can’t call it. 외출/방범 버튼/LED 5: Position (Set DRC-703S location) 홈버튼 외출/방범 버튼/LED button is for upper ground, button is for underground. Ex) When user set first floor after pushing button, “1” is displayed and pushing button, “B1” is displayed. If do not set 1st floor, automatically 1st floor will be set. 3 : Audio/Video+ 0 : Audio+ 0 : Guard Spe. Vol. (Control speaker volume when communicate with house) 1 : Guard Mic Vol. (Control Mic. volume when communicate with house) 2 : Guard Spe. Vol. (Control speaker volume when communicate with guard) 3 : Guard Mic Vol. (Control Mic. volume when communicate with guard) 4 : Gener Number Speech(Voice guide activation when press number button) 0: No (inactivated) 1. Yes(activated) 5 : Key Sound (Select button sound) 6 : Ring Sound (Select call sound) 7 : Key Vol. (Select button volume) 8 : Ring Vol. (Select call volume) 9 : Effect Vol.(Select effect volume) 10: Initialization (Initialize audio) Initialize all setting value from Audio menu. 1: Video:+ 0: Quality (Set visitor video quality) Increase to 384K/800K/1M/1.2M order (increase video quality). However, video data is also increased. If video quality is not good such as broken video, please, set lower video quality. 12 1 : Brightness (Control Video Brightness ) 2 : Contrast (Control Video Contrast) 3 : Saturation (Control Video Saturation) 4 : Hue (Control Video Hue) 5 : Initialization (Initialize Video) Initialize all setting value from Video menu. 4 : Extra Config+ 0 : Language (Select language) 1 : Skin Theme 0 : Auto Automatically change Skin Theme once a day or after booting. 1 : Flip Clock Set up Skin Theme to Flip Clock Type. 2 : Red Clock Set up Skin Theme to Red Clock Typ. 3 : Green Clock Set up Skin Theme to Green Clock Type. 4 : Black Clock Set up Skin Theme to Black Clock Type. 2 : Set Time+ 0 : Door Open Time (Gate Open time) Select between 2sec., 5sec., 10sec., 15sec., 20sec., 25sec. 1 : Sleep Mode Time (LCD Sleep Mode setting) Select between 30sec, 1 min. 2 min. 3min, 4min, 5min 2 : Key Time Out Select between 10 sec, 20 sec, 30 sec 3 : ADC Sensor (Change approach sensor and range.) Range should be small when face to direct sun-ray. 0 : [ ] 0.2V 1 : [ ] 0.3V 2 : [ ] 0.4V 3 : [ ] Unused 4 : Change Password 41 74 button for deleting previous password. 2 Push 5 : Off-Line Password (In put Off-Line password) 52 Push 63 button for deleting previous password. 85 96 13 Initial Off-Line password is “123456”. 6 : Reboot: (System rebooting) 7 : System Reset (Initialize all setting and back to factory setting) Do not initialize IP after changing IP address. 5 : Database+ 0 : Password Down. (Download house password) 1 : RF-Card Down. (Download RF-Card Data) 2 : Password Del. (Delete house password) 3 : RF-Card Del. (Delete RF-Card Datas) 6 : System Info+ 0 : Version (Show software version) 1 : Boot (Display boot loader information) 2 : Kernel (Display OS information) 7 : Test+ 0 : Test Door Open 1 : Test RF Card (Display RF card No.) This function is for checking RF Card number. Tag card to card reader when Reading status. 2 : Test Elevator (Test elevator call) 3 : Test Sensor (Display sensor value.) 4 : PTZ Camera(Unused) 5 : System Initialize (System Initialize.) 14 8. Wiring Diagram Pay attention to check polarity when install lobby panel. 15 FCC Statement 15.19: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 15.21: Note: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment. 15.105(b): Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Disclaimers The manufacturer, importer, and distributor shall not be liable for damages including accidental and personal injury due to the improper use or operation of this product. The information in this user manual was written based on current product specifications. The manufacturer, iriver Limited, is adding new complementary features and will continue to apply new technologies in the future. Product specifications may be changed without prior notice. iriver is not responsible for data loss due to product use. 16 Memo 17 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int’l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com Printed In Korea / 2014.10.104
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2014:10:29 17:03:40Z Creator : QuarkXPress(R) 6.52K Modify Date : 2017:03:06 19:15:03+09:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Creator Tool : QuarkXPress(R) 6.52K Metadata Date : 2017:03:06 19:15:03+09:00 Producer : QuarkXPress(R) 6.52K X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%DocumentCustomColors: (c100m65 º¹»çº»).%%CMYKCustomColor: 1 .65 0 0 (c100m65 º¹»çº»).%%EndComments Format : application/pdf Title : DRC-500S Document ID : uuid:ac41cf83-2c7e-469a-ac5b-5e3e26b81fab Instance ID : uuid:84147cee-5ad1-4c61-99cf-bcc2efefba45 Page Count : 19EXIF Metadata provided by EXIF.tools