COMMAX DRC-703S Lobby Phone User Manual DRC 500S

COMMAX Co., Ltd. Lobby Phone DRC 500S

User Manual

Download: COMMAX DRC-703S Lobby Phone User Manual DRC 500S
Mirror Download [FCC.gov]COMMAX DRC-703S Lobby Phone User Manual DRC 500S
Document ID3345317
Application IDMV855HB6O3Bee7xs+fdMgQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize52.85kB (660684 bits)
Date Submitted2017-04-05 00:00:00
Date Available2017-10-02 00:00:00
Creation Date2014-10-29 17:03:40
Producing SoftwareQuarkXPress(R) 6.52K
Document Lastmod2017-03-06 19:15:03
Document TitleDRC-500S
Document CreatorQuarkXPress(R) 6.52K

User Manual
COMMAX LOBBY PHONE DRC-703S
•
• Thank
Thank you
you for
for purchasing
purchasing COMMAX
COMMAXproducts.
products.
•
• Please
Please carefully
carefully read
read this
this User’s
User’sGuide
Guide(in
(inparticular,
particular,precautions
precautionsfor
forsafety)
safety)before
beforeusing
usingaaproduct
productand
andfollow
follow
instructions
instructions to
to use
use aa product
product exactly.
exactly.
•
• The
The company
company isis not
not responsible
responsible for
forany
anysafety
safetyaccidents
accidentscaused
causedby
byabnormal
abnormaloperation
operationof
ofthe
theproduct.
product.
Greetings
● Thank you for choosing COMMAX.
● Please read this manual carefully before you use the product.
Table of contents
Greetings ..................................................................................................................1
Contents table ...........................................................................................................1
1. Warnings and caution ...........................................................................................2
2. Part names............................................................................................................4
3. Main Screen Setting..............................................................................................5
4. Security Call ..........................................................................................................6
5. Call house .............................................................................................................7
6. Access authorization .............................................................................................9
7. Set up..................................................................................................................11
8. Wiring Diagram ...................................................................................................15
1. Warnings and caution
Please follow the things described below in order to prevent any
danger or property damage.
Warning
Prohibition.
It may cause a serious damage or
injury if violated.
No disassembly
No touch
Caution
Must follow strictly.
Shows plugging out the power cord
without an exception
It may cause a minor damage or
injury if violated.
Shows the warning and caution for an electric shock.
Shows the warning and caution for a fire.
Power & Installation
Warning
Please don’t use several
products at the same time on
one power socket.
·It may cause a fire due to an
abnormal overheating.
Please don’t bend the power
cable excessively or it may
cause an electric shock.
·fire when using a damaged
power cable.
Please don’t handle the power
cable with a wet hand.
·It may cause an electric
shock.
Please plug out the power
cable from the socket when
not using it for a long period
of time.
·It may shorten the product
lifespan or cause a fire.
Please don’t install the
product in the place where
there is much oil, smoke or
humidity.
·It may cause an electric
shock or fire.
Please don’t install the
product with the lightening
and thunder.
·It may cause an electric
shock or fire.
Please don’t use and connect
this product with other
products with different rated
voltage
·It may cause a disorder or
fire.
When installing the product
that generates heat, please
install the product away from
the wall (10cm) for the
ventilation.
·It may cause a fire due to
the increased internal
temperature.
Cleaning & Use
Warning
Please don’t disassemble,
repair or rebuild this product
arbitrarily (please contact the
service center if a repair is
needed.
·It may cause an electric
shock or fire.
If an abnormal sound, burning
smell or smoke is coming out
of the product, please plug out
the power cable and contact a
service center.
·It may cause an electric
shock or fire.
Please don’t insert any
metallic or burnable materials
into the ventilation hole.
·It may cause an electric
shock or fire.
Please use only the designated
batteries for the products of
using DC power.
·It may cause an electric
shock or fire.
Cleaning & Use
Power & Installation
Caution
Please plug the power cable
firmly into the inner end
·It may cause a fire.
Please hold the plug tightly
when unplugging the power
cable (a part of the copper
wire may be disconnected if
the grabbing is only made on
the cord when pulling out the
cable).
·It may cause an electric
shock or fire
When connecting the power
cables after cutting the cable,
please install the product with
power off
·It may cause an electric
shock or fire
Please be careful when using
an AC circuit breaker since
there is a possibility of an
electric shock.
Please check the use voltage
and current for the DC-only
products and use the
appropriate rectifier.
·It may cause a fire.
Please avoid direct rays of the
sun or heating devices at a
time of installation.
·It may cause a fire.
When cleaning the product,
please rub it with a soft and
dry cloth after plugging out
the power cable. (Please don’t
use any chemical products
such as wax, benzene, alcohol
or cleanser.)
Please don’t drop the product
on the ground and don’t apply
a shock .
·It may cause a failure.
Please use the designated
connection cable within the
maximum calling distance
designated for the product
·It may reduce the product
performance.
When installing the product,
please fix it firmly while using
the wall-mounting unit and
screws.
·It may cause an injury from
the falling object.
Please don’t install the
product on an unstable place
or small support board.
·It may cause an injury if it
falls down while in use.
2. Part names
①
Camera
⑪
Program Button
②
LCD
⑫
Cancel Button
③
RF CARD Receiver
⑬
Speaker
④
Mike
⑭
Reset
⑤
LED
⑮
Camera Adjustment Part
⑥
Number Key Button
⑯
DC 14V
⑦
Electric Key Button(in case of input the password)
⑰
RS-485/Zigbee
⑧
Proximity IR Sensor
⑱
Switch Connection (NO,NC)
⑨
Security Button
⑲
LAN PORT
⑩
Call Button
3. Main Screen Setting
● Main
●
Screen
Status
Icon
Description
Icon
Description
Lan Connection
Registered server status
Display out post lobby phone
Not Registered server status
Display building lobby phone
Local Server connection status
Display Video Codec(MPEG-4)
Display Video Codec(H.264)
RF Card Data save status
4. Security Call
① Push
(Security Guard Post) Button
② Push
(Call) button
③ Call sound is ringing and call Security Guard Post.
④ Call Security Guard Post when guard answer call. (Time: 1 min.)
⑤ Press "X" button when terminate call.
⑥ Security Guard push 'Open door’ button, 'Door is open” voice comment then door is
open.
⑦ If line is busy, call it later.
Picture1. Call security Guard
This is to call up the registered guard stations in advance by a manager
5. Call house
● Communication
call between residence
When building number is set in advance : When building No. already registered to Call Prefix
Picture2. Screen for registering house No.
① Input unit No. to key board.
Ex) Unit 101  input ‘101’
② Push
(call) button.
③ Ringing call sound and call unit.
④ When tenants answer call, calling is on. (Max. time: 1 min)
⑤ Press "X" button when terminate call.
⑥ Tenant push 'Open door’ button, "Door is open” voice comment then door is open
When building number is NOT set in advance :
When building number hasn't been registered Call Prefix yet.
Picture3. Building house No. register screen
① Input Building No. to key board.
Ex) Building 101  input ‘101’
② Input unit No. to key board.
Ex) Unit 101  input ‘101’
③ Push
(call) button.
④ Ringing call sound and call unit.
⑤ When tenants answer call, calling is on. (Max. time: 1 min)
⑥ Press "X" button when terminate call.
⑦ Tenant push 'Open door’ button, "Door is open” voice comment then door is open
6. Access authorization
● Opening
the entrance with RF card.
① Tag RF card to 'Card tagging window’.
② The common entrance get be opened with a vocal message, "Door opens” when
the access is successful.
③ The entrance does not be opened when the access fails with sound.
Picture4. Tag RF-Card
●
Access by PIN No.
Building Number designated case : Building Number designated in Call Prefix
① Input unit No. through key board.
② Push
(Key) button.
③ Input designated house PIN No.
④ Push
(call) button.
⑤ If access authorization is successful, Door is open with "Door is open” voice message.
⑥ If access is failed, warning sound is activated.
Building Number is not designated case :
Building Number is not designated in Call Prefix
① Input Building No. through key board.
EX) Building 101  Input 101
② Push
(call) button.
③ Input unit No. through key board.
Ex) Unit 101  Input 101
④ Push
(call) button.
⑤ If access authorization is successful, Door is open with "Door is open” voice message.
⑥ If access is failed, warning sound is activated.
Picture5. Input password (PIN)
● Use
password for accessing when system is OFF-Line
(No connection with Local server)
① Push
(Key) button.
② Input PIN number.
③ Push
(call) button.
Please, should delete OFF-LINE PIN number when On-Line mode is activated
● Use
password for accessing when system is ON-Line
(When connected with Local server)
① Push
(Key) button.
② Input Administration Pin number
③ Push
10
(call) button.
7. Set up
● Set
up
button.
1 2 1. Push
2. Input PIN number.
4 5 3. Push
6 (call) button.
7 8 We
9 recommend user change initial password (0000) then use products for security.
Initialize password :
1 2+“0000”
3 + 1+ 2+ 3 + +
button map
4 5 64 5 6 4 5 6
7 8 97 8 9 7 8 9
홈버튼
홈버튼
외출/방범 버튼/LED
외출/방범 버튼/LED
홈버튼
외출/방범 버튼/LED
●
“●”is DOT (.) for IP address typing.
● Set
up menu
0 : Set Network+
0 : IP address: (Input IP address)
1 : G/W address (Input Gateway address)
2 : DNS address (Input DNS address)
3 : Net mask (Input network mask)
1 : Set VoIP+
0 : SIP Server (Input SIP server address)
1 : Guard ID (Input Security Guard Post)
11
2 : Management+
0 : Server address (Input Local server address)
1 : Update address (Input update server address)
2 : System ID (Input DRC-700S serial No.)
3 : Call Prefix (Set building)
If there is no building information in set up, automatically pop up for building
information when call house.
4 : Call Line+
0 : Min Call Line (Input call Min. line)
1 : Max Call Line (Input call Max. line)
Attention : If Min Call Line is bigger than Max Call Line, you can’t call it.
외출/방범 버튼/LED
5: Position (Set DRC-703S location)
홈버튼
외출/방범 버튼/LED
button is for upper ground,
button is for underground.
Ex) When user set first floor after pushing
button, “1” is displayed and
pushing
button, “B1” is displayed.
If do not set 1st floor, automatically 1st floor will be set.
3 : Audio/Video+
0 : Audio+
0 : Guard Spe. Vol. (Control speaker volume when communicate with house)
1 : Guard Mic Vol. (Control Mic. volume when communicate with house)
2 : Guard Spe. Vol. (Control speaker volume when communicate with guard)
3 : Guard Mic Vol. (Control Mic. volume when communicate with guard)
4 : Gener Number Speech(Voice guide activation when press number button)
0: No (inactivated)
1. Yes(activated)
5 : Key Sound (Select button sound)
6 : Ring Sound (Select call sound)
7 : Key Vol. (Select button volume)
8 : Ring Vol. (Select call volume)
9 : Effect Vol.(Select effect volume)
10: Initialization (Initialize audio)
Initialize all setting value from Audio menu.
1: Video:+
0: Quality (Set visitor video quality)
Increase to 384K/800K/1M/1.2M order (increase video quality). However, video data is
also increased. If video quality is not good such as broken video, please, set lower
video quality.
12
1 : Brightness (Control Video Brightness )
2 : Contrast (Control Video Contrast)
3 : Saturation (Control Video Saturation)
4 : Hue (Control Video Hue)
5 : Initialization (Initialize Video)
Initialize all setting value from Video menu.
4 : Extra Config+
0 : Language (Select language)
1 : Skin Theme
0 : Auto
Automatically change Skin Theme once a day or after booting.
1 : Flip Clock
Set up Skin Theme to Flip Clock Type.
2 : Red Clock
Set up Skin Theme to Red Clock Typ.
3 : Green Clock
Set up Skin Theme to Green Clock Type.
4 : Black Clock
Set up Skin Theme to Black Clock Type.
2 : Set Time+
0 : Door Open Time (Gate Open time)
Select between 2sec., 5sec., 10sec., 15sec., 20sec., 25sec.
1 : Sleep Mode Time (LCD Sleep Mode setting)
Select between 30sec, 1 min. 2 min. 3min, 4min, 5min
2 : Key Time Out
Select between 10 sec, 20 sec, 30 sec
3 : ADC Sensor (Change approach sensor and range.)
Range should be small when face to direct sun-ray.
0 : [ ] 0.2V
1 : [ ] 0.3V
2 : [ ] 0.4V
3 : [ ] Unused
4 : Change Password
41
74
button for deleting previous password.
2 Push
5 : Off-Line Password (In put Off-Line password)
52 Push
63
button for deleting previous password.
85 96
13
Initial Off-Line password is “123456”.
6 : Reboot: (System rebooting)
7 : System Reset (Initialize all setting and back to factory setting)
Do not initialize IP after changing IP address.
5 : Database+
0 : Password Down. (Download house password)
1 : RF-Card Down. (Download RF-Card Data)
2 : Password Del. (Delete house password)
3 : RF-Card Del. (Delete RF-Card Datas)
6 : System Info+
0 : Version (Show software version)
1 : Boot (Display boot loader information)
2 : Kernel (Display OS information)
7 : Test+
0 : Test Door Open
1 : Test RF Card (Display RF card No.)
This function is for checking RF Card number.
Tag card to card reader when Reading status.
2 : Test Elevator (Test elevator call)
3 : Test Sensor (Display sensor value.)
4 : PTZ Camera(Unused)
5 : System Initialize (System Initialize.)
14
8. Wiring Diagram
Pay attention to check polarity when install lobby panel.
15
FCC Statement
15.19:
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
15.21:
Note: The grantee is not responsible for any changes or modifications not expressly approved by
the party responsible for compliance. Such modifications could void the user’s authority to operate
the equipment.
15.105(b):
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Disclaimers
The manufacturer, importer, and distributor shall not be liable for damages including accidental and
personal injury due to the improper use or operation of this product. The information in this
user manual was written based on current product specifications. The manufacturer, iriver Limited,
is adding new complementary features and will continue to apply new technologies in the future.
Product specifications may be changed without prior notice.
iriver is not responsible for data loss due to product use.
16
Memo
17
513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea
Int’l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133
Web site : www.commax.com
Printed In Korea / 2014.10.104

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2014:10:29 17:03:40Z
Creator                         : QuarkXPress(R) 6.52K
Modify Date                     : 2017:03:06 19:15:03+09:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Creator Tool                    : QuarkXPress(R) 6.52K
Metadata Date                   : 2017:03:06 19:15:03+09:00
Producer                        : QuarkXPress(R) 6.52K
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%DocumentCustomColors: (c100m65 º¹»çº»).%%CMYKCustomColor: 1 .65 0 0 (c100m65 º¹»çº»).%%EndComments
Format                          : application/pdf
Title                           : DRC-500S
Document ID                     : uuid:ac41cf83-2c7e-469a-ac5b-5e3e26b81fab
Instance ID                     : uuid:84147cee-5ad1-4c61-99cf-bcc2efefba45
Page Count                      : 19
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CCEDRC-703S

Navigation menu