Cambium Networks 89FT0035 cnPilot E410 Indoor User Manual e410 QSG 25rd May
Cambium Networks Inc. cnPilot E410 Indoor e410 QSG 25rd May
User Manual
cnPilot (410,QGRRU TM 802.11ac Wave2 Indoor Access Point Quick Start Guide Ceiling Tile Mounting Product Overview Introduction The guide provides a quick installation process. 38mm T-Bar Rail Mounting Mounting Plate Cable Route Hole Package Contents 38mm wide T-bar rail Mounting Bracket Ceiling Tile Multi-color LED e410 Access Point Ceiling Mounting Bracket Mounting Plate Mounting Bracket Screws x4 Top View Wall Mounting Kit Ceiling Mounting Screws Rubber Foot (Qty. 2) (Qty. 4) (Qty. 4) Desk Mount Foot T-bar Mount Holder Ceiling Tile Tool Requirements Wall Mount Anchor POE Injector* Power Cord* Exploded View Tools Required ⢠Philips Screwdriver Reset Button LAN Port Kensington Removable Clip Lock Slot The e410 mounts to a ceiling tile and allows for the The e410 is secured to a 38mm ceiling T-bar rail by using ethernet cable to be hidden by routing through a hole in the ceiling mount bracket. the ceiling tile. Bottom View Model: e410 * Only available for certain ordering SKUs 24mm T-Bar Rail Mounting 14mm T-Bar Rail Mounting Wall Mounting Rubber feet Assembly 24mm wide T-bar rail 14mm wide 118mm T-bar rail Ceiling Tile Ceiling Tile JOIN THE CONVERSATION The e410 can be mounted to a 24mm width T-bar rail The e410 can be mounted to a 14mm width T-bar rail The e410 mounts to any wall by using two screws with The e410 can be mounted on any surface by attaching using the clips built into the underside of the unit. using the clips built into the underside of the unit. corresponding wall anchors. the rubber feet to the underside of the unit. community.cambiumnetworks.com Powering Up 1. 2. Configure Management PC Connect the Ethernet cable from Eth1/PoE-IN of e410 to the PoE 1. Select Properties for the Ethernet port. In Windows it is found in port of Gigabit Data + Power. Control Panel > Network and Internet > Network Connections > Connect an Ethernet cable from your LAN or Computer to the Local Area Connection. Gigabit Data port of the PoE adapter. AP Management Hardware Overview Hardware Overview The cnPilot e410 Access Point supports multiple modes of management: Standalone: The Access Point can be managed directly from its GUI by selecting the âConďŹgureâ tab on the menu, and setting up a wireless LAN. Controller : The Access Point can be onboarded to cnMaestro network controller system, either on-premises or the cloud version at IP Address ConďŹguration Default IP address received via DHCP. cn Pilot e410 will use a default static IP address of 192.168.0.1, If there is no DHCP server 3. For management from cloud please ensure the AP has connectivity to the internet. Connectivity can be veriďŹed using tools such as ping from Connect the Power Cord to the adapter, and then plug the Power the âTroubleshootingâ tab of the Access Point GUI. Connection status can Cord into a power outlet. be monitored from the AP dashboard. Bottom View LED Color Amber Green Blue Status Access Point is Access Point is Access Point is Indicator powering up in service. managed with and Intitializing 3. Default Login information cnMaestro or autopilot. - Username: admin PoE Adapter. Specifications &( &WLFN 0+] )&& ,& 0+] Reset The Reset button serves two functions for e410: - To restart, press and release the Reset button quickly. - To restore to factory default settings, press and hold the Reset button for more than 10 seconds. - Password: admin Once powered ON -- Power LED should illuminate continuously on LAN Port Reset Button https://cloud.cambiumnetworks.com. 2. LAN Port Management Protocols enabled by default âhttp or https (webpage The Main port is a Gigabit Ethernet port used to connect the power and management interface access), SSH (CLI management interface access). should be connected to the LAN and DHCP server. Safety Notice Warning: To prevent loss of life or physical injury, observe the following safety guidelines. In no event shall Cambium Networks be liable for any injury or damage caused during the installation of e410 platform. Ensure that only qualiďŹed personnel install. Only use attachments/accessories speciďŹed by the manufacturer. Electrical Safety Information 1. Compliance with manufacturerâs label for voltage, frequency, and current requirements. Connecting to a different power source than those speciďŹed may result in improper operation, damage to equipment or pose a ďŹre hazard if the limitations are not followed. 2. There are no serviceable parts inside this equipment. Service should be provided only by a qualiďŹed service technician. 3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet. 4. a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. b. The equipment requires the use of the ground wire as a part of the safety certiďŹcation, modiďŹcation or misuse can provide a shock hazard that can result in serious injury or death. c. Contact a qualiďŹed electrician or the manufacturer if there are questions about the installation prior to connecting the equipment. d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection. e. Protective bonding must be installed in accordance with local national wiring rules and regulations. Be aware that the unit surfaces can become very hot to the touch so do not handle the device when it is running for long periods of time. Turn off power to the device ďŹrst for a few minutes and then handle the unit carefully. FCC Compliance Changes or modiďŹcations not expressly approved by the party responsible for compliance could void the userâs authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible. This device is restricted for indoor use. IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. IC Statement: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prĂŠsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisĂŠe aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioĂŠlectrique subi, mĂŞme si le brouillage est susceptible d'en compromettre le fonctionnement. FCC Compliance RoHS/WEEE Compliance For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible. Pour les produits disponibles aux Ătats-Unis / Canada du marchĂŠ, seul le canal 1 Ă 11 peuvent ĂŞtre exploitĂŠs. SĂŠlection d'autres canaux n'est pas possible. Caring for the Environment: RoHS/WEEE Dynamic Frequency Selection (DFS) for devices operating in the bands 5250- 5350 MHz, 5470-5600 MHz and 5650-5725 MHz. SĂŠlection dynamique de frĂŠquences (DFS) pour les dispositifs fonctionnant dans les bandes 5250-5350 MHz, 5470-5600 MHz et 5650-5725 MHz. The device for operation in the band 5150â5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems. les dispositifs fonctionnant dans la bande 5150-5250 MHz sont rĂŠservĂŠs uniquement pour une utilisation Ă lâintĂŠrieur aďŹn de rĂŠduire les risques de brouillage prĂŠjudiciable aux systèmes de satellites mobiles utilisant les mĂŞmes canaux. European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product. For indoor use only. Pour une utilisation en intĂŠrieur uniquement. IMPORTANT NOTE: IC Radiation Exposure Statement: This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. Cet ĂŠquipement est conforme aux limites d'exposition aux rayonnements IC ĂŠtablies pour un environnement non contrĂ´lĂŠ. Cet ĂŠquipement doit ĂŞtre installĂŠ et utilisĂŠ avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. This radio transmitter has been approved by FCC to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Antenna Information: Two dual-band antenna, 0D[Gain 5.24/5.47dBi CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. Online Resources User Guide and software downloads: https://support.cambiumnetworks.com/ďŹles/e410/ Support: http://www.cambiumnetworks.com/support/ Contact us: http://www.cambiumnetworks.com/support/contact-support/
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 1 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:a14c0c8d-9775-11f2-0000-02c7314339d4 Producer : GPL Ghostscript 9.18 Modify Date : 2017:07:02 19:03:06Z Create Date : 2017:07:02 19:03:06Z Creator Tool : UnknownApplication Document ID : uuid:a14c0c8d-9775-11f2-0000-02c7314339d4 Format : application/pdf Title : UntitledEXIF Metadata provided by EXIF.tools