Carrier 25Hcd3 Product Data ManualsLib Makes It Easy To Find Manuals Online!

2014-12-12

: Carrier Carrier-25Hcd3-Product-Data-119358 carrier-25hcd3-product-data-119358 carrier pdf

Open the PDF directly: View PDF PDF.
Page Count: 24

DownloadCarrier Carrier-25Hcd3-Product-Data- ManualsLib - Makes It Easy To Find Manuals Online!  Carrier-25hcd3-product-data
Open PDF In BrowserView PDF
25HCD3
Comfort™ 13 Heat Pump
with Puronr Refrigerant
1---1/2 to 5 Nominal Tons

Product Data
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S 13.0 -- 14.5 SEER/ 11.0 -- 12.2 EER/ 7.7 -- 8.5 HSPF
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available

Sound
S Sound level as low as 69 dBA
S Sound levels as low as 69 dBA with accessory sound blanket

Comfort
S System supports Edger Thermidistatt or standard thermostat
controls

Reliability
S Puronr refrigerant -- environmentally sound, won’t deplete the
ozone layer and low lifetime service cost.
S Scroll compressor
S Internal pressure relief valve
S Internal thermal overload
S High pressure switch
S Loss of charge switch
S Filter drier
S Balanced refrigeration system for maximum reliability
the environmentally sound refrigerant

Carrier heat pumps with Puronr refrigerant provide a collection of
features unmatched by any other family of equipment. The 25HCD
has been designed utilizing Carrier’s Puron refrigerant. The
environmentally sound refrigerant allows consumers to make a
responsible decision in the protection of the earth’s ozone layer.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings
information.

Durability
WeatherArmort protection package:
S Solid, durable sheet metal construction
S Dense wire coil guard
S Baked--on powder paint

Applications
S Long--line -- up to 250 feet (76.20 m) total equivalent length, up
to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft.
(24.38 m) evaporator above condenser (See Longline Guide for
more information.)
S Low ambient (down to --20_F/--28.9_C) with accessory kit

MODEL NUMBER NOMENCLATURE
1
N

2
N

3
A

4
A

5
A/N

6
N

7
N

8
N

9
A/N

10
A/N

11
A/N

12
N

13
N

2

5

H

C

D

3

3

6

A

0

0

3

0

Product
Family

Tier

Major
Series

SEER

Grille
Variations

Open

Open

Voltage

Minor
Series

A=Dense Grille
W=Wide Grille

0=Not
Defined

0=Not
Defined

3=208/230 ---1
5=208/230 ---3
6=460/3

0, 1, 2...

Product
Series
25 = HP

H = RES HP C=Comfort D = Puron

25HCD3

the environmentally sound refrigerant

Cooling
Capacity

3=13 SEER

Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.

STANDARD FEATURES
Feature

18

24

30

36

42

48

60

Puron Refrigerant

X

X

X

X

X

X

X

Scroll Compressor

X

X

X

X

X

X

X

Field Installed Filter Drier

X

X

X

X

X

X

X

Front Seating Service Valves

X

X

X

X

X

X

X

Internal Pressure Relief Valve

X

X

X

X

X

X

X

Internal Thermal Overload

X

X

X

X

X

X

X

Long Line capability

X

X

X

X

X

X

X

Low Ambient capability with Kit

X

X

X

X

X

X

X

Suction Line Accumulator

X

X

X

X

X

X

X

High Pressure Switch

X

X

X

X

X

X

X

Loss of Charge Switch

X

X

X

X

X

X

X

X = Standard

2

PHYSICAL DATA
Operating Weight lb (kg)
Shipping Weight lb (kg)

18--- 30

24--- 30

119
(54.1)
137
(62.3)

124
(56.4)
142
(64.5)

Piston
49

Piston
57

42
4.0
(1.81)

49
5.11
(2.32)

36--- 31, 50,
42--- 31, 50
60
149
169
180
(67.7)
(76.7)
(81.6)
170
189
200
(77.3)
(85.9)
(90.9)
Scroll
Puron (R---410A)
Piston
Piston
Piston
70 (31)
67
76
73 (50,60)
55
57
63
5.83
6.06
6.75
(2.64)
(2.75)
(3.06)
Propeller Type, Direct Drive
Vertical
3000
3000
3400
1/5
1/5
1/4
1100
1100
1100

Compressor Type
REFRIGERANT
Indoor Control
Outdoor Heating Piston #
Charge lb (kg)

48--- 31, 50,
60
208
(94.3)
228
(103.6)

30--- 30, 50

COND FAN
Air Discharge
Air Qty (CFM)
1800
2100
Motor HP
1/12
1/10
Motor RPM
1100
1100
COND COIL
Face Area (Sq ft)
9.8
11.2
15.0
Fins per In.
20
20
20
Rows
1
1
1
Circuits
3
4
5
VALVE CONNECT. (In.) ID
Vapor
5/8
5/8
3/4
Liquid
REFRIGERANT TUBES (In.) OD
Rated Vapor*
5/8
5/8
3/4
Liquid
*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss
Note: See unit Installation Instruction for proper installation.

60--- 30, 50, 60

Piston
80 (31)
82 (50, 60)
65
7.72
(3.50)

250
(113.4)
282
(127.9)

TXV
(Puron Hard
Shutoff)

76
11.00
(4.99)

3400
1/4
1100

4000
1/4
800

17.2
20
1
5

17.2
20
1
5

15.0
20
2
6

17.6
20
2
8

3/4
3/8

7/8

7/8

7/8

3/4
7/8
7/8
1 ---1/8
3/8”
table when using other sizes and lengths of lineset.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for HP systems with Puron refrigerant:
Vapor Line Sizing and Cooling Capacity Losses -- Puronr Refrigerant 1-- Stage Heat Pump Applications
Unit
Nominal
Size (Btuh)
18,000
1--- Stage
HP with
Puron
24,000
1--- Stage
HP with
Puron
30,000
1--- Stage
HP with
Puron
36,000
1--- Stage
HP with
Puron
42,000
1--- Stage
HP with
Puron
48,000
1--- Stage
HP with
Puron
60,000
1--- Stage
HP with
Puron

Maximum
Liquid Line
Diameters
(In. OD)

3/8

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line
Diameters
(In.) OD

Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
Standard
Application
26--- 50
51--- 80

Long Line Application Requires Accessories
81--- 100

101--- 125

126--- 150

151--- 175

176--- 200

201--- 225

226--- 250

(7.9--- 15.2)

(15.5--- 24.4)

(24.7--- 30.5)

(30.8--- 38.1)

(38.4--- 45.7)

(46.0--- 50.3)

(53.6--- 60.0)

(61.3--- 68.6)

(68.9--- 76.2)

1/2

1

2

3

4

6

7

8

9

10

5/8

0

0

1

1

1

2

2

3

3

5/8

0

1

1

2

3

3

4

4

5

3/4

0

0

0

0

1

1

1

1

1

5/8

1

2

3

3

4

5

6

7

8

3/4

0

0

1

1

1

2

2

2

3

7/8

0

0

0

0

1

1

1

1

1

5/8

1

2

4

5

6

7

9

10

11

3/4

0

0

1

1

2

2

3

3

4

7/8

0

0

0

0

1

1

1

1

2

3/4

0

1

2

2

3

4

4

5

6

7/8

0

0

1

1

1

2

2

2

3

3/4

0

1

2

3

4

5

5

6

7

7/8

0

0

1

1

2

2

2

3

3

3/4

1

2

4

5

6

7

9

10

11

7/8

0

1

2

2

3

4

4

5

5

1 ---1/8

0

0

0

1

1

1

1

1

1

Standard Length = 80 ft. (24.4 m) or less total equivalent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines

3

25HCD3

UNIT SIZE SERIES

REFRIGERANT PIPING LENGTH LIMITATIONS
Maximum Line Lengths:
The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for
allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit.
Maximum Line Lengths for Heat Pump Applications
MAXIMUM ACTUAL LENGTH
ft (m)

MAXIMUM EQUIVALENT LENGTH{
ft (m)

MAXIMUM VERTICAL
SEPARATION ft (m)

Units on equal level

200 (61)

250 (76.2)

N/A

Outdoor unit ABOVE
indoor unit

200 (61)

250 (76.2)

200 (61)

Outdoor unit BELOW
indoor unit

See Table ’Maximum Total Equivalent Length: Outdoor Unit BELOW Indoor Unit’

{ Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.

25HCD3

Maximum Total Equivalent Length{ -- Outdoor Unit BELOW Indoor Unit
Size

Liquid Line
Diameter
w/ TXV

18000
HP with
Puron
24000
HP with
Puron
30000
HP with
Puron
36000
HP with
Puron
42000
HP with
Puron
48000
HP with
Puron
60000
HP with
Puron

0--- 20
(0 --- 6.1)

HP with Puronr Refrigerant --- Maximum Total Equivalent Length{
Vertical Separation ft (m) Outdoor unit BELOW indoor unit;
21--- 30
31--- 40
41--- 50
51--- 60
61--- 70
(6.4 --- 9.1)
(9.4 --- 12.2)
(12.5 --- 15.2)
(15.5 --- 18.3)
(18.6 --- 21.3)

71--- 80
(21.6 --- 24.4)

3/8

250*

250*

250*

250*

250*

250*

250*

3/8

250*

250*

250*

250*

250*

250*

250*

3/8

250*

250*

250*

250*

250*

250*

250*

3/8

250*

250*

250*

250*

250*

250*

250*

3/8

250*

250*

250*

250*

250*

250*

150

3/8

250*

250*

250*

250*

230

160

--- ---

3/8

250*

225*

190

150

110

--- ---

--- ---

* Maximum actual length not to exceed 200 ft (61 m)
{ Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.
--- --- = outside acceptable range

LONG LINE APPLICATIONS
An application is considered Long Line when the refrigerant level in the system requires the use of accessories to maintain acceptable
refrigerant management for systems reliability. Defining a system as long line depends on the liquid line diameter, actual length of the tubing,
and vertical separation between the indoor and outdoor units.
For Heat Pump systems, the chart below shows when an application is considered Long Line. Beyond these lengths, long line accessories
are required:
HP WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m)
Beyond these lengths, long line accessories are required
Liquid Line Size

Units On Same Level

Outdoor Below Indoor

Outdoor Above Indoor

3/8

80 (24.4)

20 (6.1) vertical or 80 (24.4) total

80 (24.4)

Note: See Long Line Guideline for details

4

ACCESSORIES
DESCRIPTION

18--- 30 24--- 30 30--- 30 30--- 50 36--- 31

HC32GE234

BALL BEARING MOTOR

HC34GE239

BALL BEARING MOTOR

HC36GE219

BALL BEARING MOTOR

HC34GE240

BALL BEARING MOTOR

HC38GE232

BALL BEARING MOTOR

HC38GE461

BALL BEARING MOTOR

HC38GE228

BALL BEARING MOTOR

HC40GE226

BALL BEARING MOTOR

HC40GE466

BALL BEARING MOTOR

HC40GE228

BALL BEARING MOTOR

HC40GE467

BALL BEARING MOTOR

KAACH1701AAA

CRANKCASE HTR

KAACH1601AAA

CRANKCASE HTR

STANDARD

CRANKCASE HTR

KSACY0101AAA

CYCLE PROTECTOR

X

X

X

X

KAAFT0101AAA

FREEZE THERMOSTAT

X

X

X

KSAHS1701AAA

HARD START

X

X

KHAIR0101AAA

ISOLATION RELAY

X

KSALA0301410

LOW AMBIENT PSW

KSALA0601AAA{

36--- 50

36--- 60

42--- 31

42--- 50

X

X

48--- 31

48--- 50

X

X

48--- 60

60--- 30,
60--- 60
50

X
X
X

X

X

X

X

X
X
X
X

X

X

X
X
S

S

S

S

S

S

S

S

S

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

MOTORMASTER 230V

X

X

X

X

X

X

X

X

X

X

X

X

X

X

KHAOT0201SEC

OUTDOOR THERMOSTAT

X

X

X

X

X

X

X

X

X

X

X

X

X

X

KHAOT0301FST

OUTDOOR THERMOSTAT

X

X

X

X

X

X

X

X

X

X

X

X

X

X

KHALS0401LLS

SOLENOID VALVE

X

X

X

X

X

X

X

X

X

X

X

X

X

X

KHASS0606MPK*

SNOW STAND RACK

X

X

X

X

X

X

X

X

X

X

X

X

X

KSASH0601COP

SOUND BLKT

X

X

X

X

X

X

X

X

X

X

X

X

KSASH2101COP

SOUND BLKT

X

X

KAACS0201PTC

START ASSIST PTC

X

X

X

X

X

X

X

X

X

X

X

X

X

X

KSASF0101AAA

SUPPORT FEET

X

X

X

X

X

X

X

X

X

X

X

X

X

X

KAATD0101TDR

TIME DELAY RELAY

X

X

X

X

X

X

X

X

X

X

X

X

X

X

KSATX0201PUR

TXV PURON HSO

X

X

X

X

KSATX0301PUR

TXV PURON HSO

X

X

X

X

X

KSATX0401PUR

TXV PURON HSO

X

X

X

KSATX0501PUR
TXV PURON HSO
X
X
x = Accessory S = Standard
* Available through RCD
{ Required accessories include ball bearing fan motor, compressor start assist (CAP / Relay), crankcase heater, evaporator freeze stat, isolation relay, hard
shut---off TXV or liquid line solenoid valve.

ACCESSORY THERMOSTATS
PART NUMBER
TC ---PHP01
TC ---NHP01

PROGRAM
5 ---2 Day
NP

TCSNHP01
TB---PHP01

NP
5 ---2 Day

TB---NHP01

NP

PART NUMBER
TSTATXXCNV10‡
TX ---LBP01
TX ---MBP01
TX ---SBP01

GAS

ELECTRIC

HEAT PUMP

√
√

√
√
√
√
√

√
√
√
√
√

THERMOSTAT ACCESSORIES
BRIEF DESCRIPTION
Thermostat Conversion Kit (4 to 5 wire) --- 10 pack
Large Decorative Backplate
Medium Decorative Backplate
Small Decorative Backplate

5

HEAT
3
3

COOL
2
2

2
2

1
1

2

1

THERMOSTATS USED WITH
All Carrier branded thermostats
TP---Pxx, TP---Nxx, TC ---Pxx
TC ---Nxx, TB---Pxx
TB---Nxx

25HCD3

ORDER NUMBER

ACCESSORY USAGE GUIDELINE

Standard
No

REQUIRED FOR
SEA COAST APPLICATIONS
(Within 2 miles / 3.22 km)
Standard
No

Yes

Yes

No

Crankcase Heater

Yes

Yes

No

Evaporator Freeze Thermostat
Hard Shutoff TXV
Isolation Relay
Liquid Line Solenoid Valve
Motor Master Control or
Low Ambient Switch
Support Feet

Yes
Yes
Yes
No

No
Yes
No
See Long---Line Application Guideline

No
Yes
No
No

Yes

No

No

Recommended

No

Recommended

Accessory
Accumulator
Ball Bearing Fan Motor
Compressor Start Assist Capacitor and
Relay

REQUIRED FOR LOW --- AMBIENT
COOLING APPLICATIONS
(Below 55F / 12.8C)
Standard
Yes{

REQUIRED FOR
LONG LINE APPLICATIONS*

25HCD3

* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline
Application Guideline.
{ Additional requirement for Low---Ambient Controller (full modulation feature) MotorMasterr Control.

Accessory Description and Usage (Listed Alphabetically)
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction
while maintaining bearing lubrication.
Usage Guideline:
Required on all units when using MotorMasterr
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor motor
at each start up.
Usage Guideline:
Required for reciprocating compressors in the following
applications:
Long line
Low ambient cooling
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for single--phase scroll compressors in the
following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of
low voltage problems.
3. Compressor Start Assist — PTC Type
Solid state electrical device which gives a ”soft” boost to the
compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the
compressor to keep the lubricant warm during off cycles. Improves
compressor lubrication on restart and minimizes the chance of
liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications.
Suggested in all commercial applications.
5. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation
when evaporator reaches freeze--up conditions.
Usage Guideline:
Required when low ambient kit has been added.

6. Isolation Relay
An SPDT relay which switches the low--ambient controller out of
the outdoor fan motor circuit when the heat pump switches to
heating mode.
Usage Guideline:
Required in all heat pumps where low ambient kit has
been added.
7. Liquid--Line Solenoid Valve (LLS)
An electrically operated shutoff valve which stops and starts
refrigerant liquid flow in response to compressor operation. It is to
be installed at the outdoor unit to control refrigerant off cycle
migration in the heating mode.
Usage Guideline:
An LLS is required in all long line heat pump
applications to control refrigerant off cycle migration in
the heating mode. See Long Line Guideline.
8. Low--Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit
service valve. It is designed to cycle the outdoor fan motor in order
to maintain head pressure within normal operating limits. The
control will maintain working head pressure at low--ambient
temperatures down to 0_F (--18_C) when properly installed.
Usage Guideline:
A Low--Ambient Pressure Switch or MotorMasterr
Low--Ambient Controller must be used when cooling
operation is used at outdoor temperatures below 55_F
(12.8_C).
9. MotorMasterr Low--Ambient Controller
A fan--speed control device activated by a temperature sensor,
designed to control condenser fan motor speed in response to the
saturated, condensing temperature during operation in cooling
mode only. For outdoor temperatures down to --20_F (--28.9_C), it
maintains condensing temperature at 100_F 10_F (37.8_C 
6.5_C).
Usage Guideline:
A MotorMasterr Low Ambient Controller or
Low--Ambient Pressure Switch must be used when
cooling operation is used at outdoor temperatures
below 55_F (12.8_C).
Suggested for all commercial applications.

6

10. Outdoor Air Temperature Sensor
Designed for use with Carrier Thermostats listed in this
publication. This device enables the thermostat to display the
outdoor temperature. This device also is required to enable special
thermostat features such as auxiliary heat lock out.
Usage Guideline:
Suggested for all Carrier thermostats listed in this
publication.
11. Outdoor Thermostat
An SPDT temperature--actuated switch which turns on
supplemental electric heaters when outdoor air temperature drops
below a user--selected set point.
Usage Guideline:
Electric supplemental heat applications in non--variable
speed indoor units when electric heat staging is desired.
12. Secondary Outdoor Thermostat
An SPDT temperature--actuated switch which turns on third--stage
of supplemental electric heaters when outdoor air temperature
drops below the second--stage set point.
Usage Guideline:
Outdoor thermostat applications where electric heater is
capable of 3--stage operation.
13. Snow Stand Rack
Coated wire rack which supports unit 18 in. (457.2 mm) above
mounting pad to allow for drainage from unit base.
Usage Guideline:
Suggested in the following applications:
Heat pump installations in heavy snowfall areas.
Heat pump installations in snow drift locations.
Heat pump installations in areas of prolonged
subfreezing temperatures.
All commercial installations.

14. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces the
sound level by about 2 dBA.
Usage Guideline:
Suggested when unit is installed closer than 15 ft.
(4.577 m) to quiet areas, bedrooms, etc.
Suggested when unit is installed between two houses less
than 10 ft. (3.05 m) apart.
15. Thermostatic Expansion Valve (TXV) Bi--Flow
A modulating flow--control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Usage Guideline:
Accessory required to meet AHRI rating and system
reliability, where indoor not equipped.
Required in all heat pump applications designed with
Puron refrigerant.
16. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor
blower motor to provide additional cooling after the compressor
cycles off.
Note: Most indoor unit controls include this feature. For those that
do not, use the guideline below.
Usage Guideline:
Accessory required to meet AHRI rating, where indoor
not equipped.

7

25HCD3

Accessory Description and Usage (Listed Alphabetically) -- CONTINUED

ELECTRICAL DATA
UNIT
SIZE

V/PH

OPER VOLTS*

25HCD3

MAX

MIN

COMPR
LRA

FAN

RLA

MCA

FLA

MIN
WIRE
SIZE†

MIN
WIRE
SIZE†

MAX
LENGTH
ft (m)‡

MAX
LENGTH
ft (m)‡

60° C

75° C

60° C

75° C

MAX
FUSE**
or CKT
BRK
AMPS
20
25
30
35
40
45
50
20
20
30
30
30
10
10
15

18--- 30
48.0
9.0
0.5
11.8
14
14
66 (20.1)
62 (18.9)
24--- 30
58.3
12.8
0.77
16.8
14
14
46 (14.0)
44 (13.4)
30--- 30
77.0
16.0
1.1
21.1
12
12
57 (17.4)
54 (16.5)
36--- 31
208/230/1
253
197
70.0
15.6
1.1
20.6
12
12
60 (18.3)
57 (17.4)
42--- 31
96.0
18.0
1.4
23.9
12
12
52 (15.8)
50 (15.2)
48--- 31
99.0
21.8
1.4
28.7
10
10
69 (21.0)
66 (20.1)
60--- 30
134.0
26.3
1.2
34.1
8
8
89 (27.1)
84 (25.6
30--- 50
71.0
10.0
1.1
13.6
14
14
65 (19.8)
62 (18.9)
36--- 50
73.0
10.4
1.1
14.1
14
14
61 (18.6)
58 (17.7)
42--- 50
208/230/3
253
197
83.1
13.6
1.4
18.4
14
14
48 (14.6)
46 (14.0)
48--- 50
83.1
13.8
1.4
18.7
14
14
48 (14.6)
46 (14.0)
60--- 50
110.0
15.9
1.2
21.1
12
12
66 (20.1)
63 (19.2)
36--- 60
38.0
5.8
0.6
7.9
14
14
227 (69.2)
216 (65.8)
48--- 60
460/3
253
197
41.0
6.2
0.7
8.5
14
14
202 (61.6)
192 (58.5)
60--- 60
52.0
7.8
0.6
10.4
14
14
165 (50.3)
157 (47.9)
* Permissible limits of the voltage range at which the unit will operate satisfactorily
{ If wire is applied at ambient greater than 30_C, consult table 310 ---16 of the NEC (NFPA 70). The ampacity of non ---metallic---sheathed cable (NM),
trade name ROMEX, shall be that of 60_C conditions, per the NEC (NFPA 70) Article 336 ---26. If other than uncoated (no ---plated), 60 or 75_C
insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70).
} Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time ---Delay fuse.
FLA --- Full Load Amps
LRA --- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- Rated Load Amps
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2007 requirements of ASHRAE Standards 90.1

A--WEIGHTED SOUND POWER
UNIT SIZE
18--- 30
24--- 30
30--- 30, 50
36--- 31
36--- 50, 60
42--- 31
42--- 50
48--- 31
48--- 50, 60
60--- 30, 50, 60

STANDARD
RATING
(dBA)
69
73
74
73
75
77
79
80
80
77

TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125

250

500

1000

2000

4000

8000

49.0
51.0
52.5
50.5
53.5
55.0
55.0
59.0
59.5
55.0

57.0
59.5
64.0
62.5
63.0
65.0
67.0
67.0
69.5
63.0

63.0
66.0
68.0
67.0
69.0
71.0
71.0
72.5
74.0
67.5

65.0
68.5
69.0
68.5
71.0
72.0
74.5
75.0
76.0
71.5

61.0
63.5
67.0
66.5
67.0
70.0
70.0
73.5
72.5
68.0

57.5
59.0
64.5
63.5
63.5
67.0
67.0
69.5
69.5
64.0

52.5
53.0
58.5
58.0
58.0
59.5
60.0
61.5
64.5
60.5

NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).

A--WEIGHTED SOUND POWER WITH SOUND HOOD
UNIT SIZE
18--- 30
24--- 30
30--- 30, 50
36--- 31
36--- 50, 60
42--- 31
42--- 50
48--- 31
48--- 50, 60
60--- 30, 50, 60

STANDARD
RATING
(dBA)
69
71
73
73
74
77
78
79
79
74

TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125
50.0
51.5
53.0
52.0
54.0
55.0
56.0
60.0
58.5
55.0

250
57.0
59.0
64.0
63.0
63.5
65.5
67.0
66.5
69.0
63.5

500
63.0
65.5
68.0
66.5
68.5
71.0
71.0
72.5
73.5
67.0

1000
64.5
67.5
68.0
68.0
70.0
72.0
73.5
74.5
74.5
69.0

2000
61.0
63.0
66.5
65.5
66.0
70.0
69.5
73.5
71.5
66.5

NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).

CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE --- SERIES
18--- 30
24--- 30
30--- 30, 50
36--- 31
36--- 50, 60
42--- 31
42--- 50
48--- 31
48--- 50, 60
60--- 30, 50, 60
NOTE: Subcooling is for field installed TXV (except for 060)

REQUIRED SUBCOOLING* ° F (° C)
13 (7.2)
13 (7.2)

9 (5.0)
14 (7.8)
9 (5.0)
15 (8.3)
13 (7.2)
17 (9.4)
13 (7.2)
15 (8.3)

8

4000
57.0
58.5
63.5
62.5
63.0
66.0
66.5
69.0
68.0
62.0

8000
51.0
53.0
57.0
56.5
57.0
59.5
60.0
61.0
62.0
57.0

9

DIMENSIONS -- ENGLISH

25HCD3

10

DIMENSIONS -- SI

25HCD3

11

0

0

BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH

C

F

-23.3

0
-10.0

10

20

30

40

50

60

70

80

-17.8

0.0
-12.2

10.0

25HCD3 BALANCE POINT WORKSHEET

-1.1

30.0

4.4

40.0

OUTDOOR TEMPERATURE

-6.7

20.0

10.0

50.0

25HCD3

15.6

60.0

21.1

70.0

BASED ON INDOOR ENTERING
AIR AT 70◦F (21.1◦C) AND AT RATED
CFM

25HCD318
FB4CNF018

25HCD324
FB4CNF024

25HCD330
FB4CNF030

25HCD336
FB4CNF036

25HCD342
FB4CNF042

25HCD348
FB4CNF048

25HCD360
FY5BNB060

26.7

0.0
80.0

2.9

5.9

8.8

11.7

14.7

17.6

20.5

23.4

kW

12

24”
(609.6)
Service

12”
(304.8)

Note: Numbers in ( ) = mm

18”
(457.2)

24”
(609.6)
Service

Wall
6”
(152.4)

18”
(457.2)

12”
(304.8)

24”
(609.6)
Service

Wall

18”
(457.2)

12”
(304.8)

Clearances (various examples)

24”
(609.6)
Service

12”
(304.8)

24”
(609.6)
Service

Wall

6”
(152.4)

IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re--circulation of discharge air.

CLEARANCES

25HCD3

Wall

TESTED AHRI* COMBINATION RATINGS
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Carrier database at: www.MyCarrierRatings.com
For performance data at specific application &/or design conditions with various indoor unit combinations, the
equipment performance calculator can be accessed at : http://rpmob.wrightsoft.com/
High Temp

Low Temp

EER

SEER

Capacity
47˚F (8_C)

COP

FB4CNF018

17,400

11.0

13.0

16,700

25HCD324(A,W)**30

FB4CNF024

23,400

11.0

13.0

25HCD330(A,W)**30

FB4CNF030

28,600

11.0

25HCD330(A,W)**50

FB4CNF030

28,600

25HCD336(A,W)**31

FB4CNF036

25HCD336(A,W)**50

Coil Model Number

HSPF

Capacity
17˚F ( --- 8_C)

25HCD318(A,W)**30

COP

3.60

7.7

9,400

2.24

22,000

3.48

7.7

13,000

2.28

13.0

29,600

3.50

7.7

17,700

2.34

11.0

13.0

29,600

3.50

7.7

17,700

2.34

33,600

11.0

13.0

33,000

3.50

7.7

20,200

2.40

FB4CNF036

33,600

11.0

13.0

33,000

3.54

7.7

20,200

2.40

25HCD336(A,W)**60

FB4CNF036

33,600

11.0

13.0

33,000

3.54

7.7

20,200

2.40

25HCD342(A,W)**31

FB4CNF042

42,000

11.0

13.0

39,500

3.60

8.0

24,400

2.40

25HCD342(A,W)**50

FB4CNF042

42,000

11.0

13.0

39,500

3.62

8.0

24,000

2.44

25HCD348(A,W)**31

FB4CNF048

47,000

11.0

13.0

45,000

3.48

8.0

28,600

2.44

25HCD348(A,W)**50

FB4CNF048

47,000

11.0

13.0

45,000

3.58

8.0

28,200

2.50

25HCD348(A,W)**60

FB4CNF048

47,000

11.0

13.0

45,000

3.58

8.0

28,200

2.50

25HCD360(A,W)**30

FY5BNB060

58,500

10.8

13.0

57,000

3.52

7.7

37,000

2.50

25HCD360(A,W)**50

FY5BNB060

58,500

10.8

13.0

57,000

3.52

7.7

37,000

2.50

25HCD360(A,W)**60

FY5BNB060

58,500

10.8

13.0

57,000

3.52

7.7

37,000

2.50

* AHRI = Air Conditioning, Heating & Refrigeration Institute

* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit.
High---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 47_F (8_C) db 43° F (6_C) wb air entering outdoor unit.
Low---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 17_F (---8_C) db 15° F (---9_C) wb air entering outdoor unit.
COP — Coefficient of Performance
EER — Energy Efficiency Ratio
HSPF — Heating Seasonal Performance Factor
SEER — Seasonal Energy Efficiency Ratio

13

25HCD3

Furnace
Model
Number

Cooling
Capacity

Model Number

14

57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)

57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)

EWB
° F (° C)

See notes on page 17

900

800

700

CFM

EVAPORATOR AIR

675

600

525

CFM

EWB
° F (° C)

EVAPORATOR AIR

75 (23.9)

16.65
15.33
12.51
13.04
10.63
17.43
16.48
13.33
13.89
11.12
18.11
17.49
14.11
14.69
11.57

Sens‡

22.27
23.17
23.65
25.62
28.04
23.24
23.74
24.17
26.14
28.50
24.05
24.25
24.60
26.54
28.85

Total

22.27
20.79
16.96
17.65
14.27
23.24
22.26
18.01
18.72
14.87
24.05
23.56
19.04
19.73
15.42

Sens‡

Capacity MBtuh

16.65
17.30
17.67
19.21
21.16
17.43
17.78
18.10
19.65
21.57
18.11
18.22
18.46
19.98
21.88

Total

Capacity MBtuh

75 (23.9)

1.62
1.63
1.63
1.66
1.70
1.65
1.66
1.67
1.69
1.73
1.69
1.69
1.69
1.72
1.76

Total
System
KW**

1.22
1.22
1.22
1.23
1.25
1.24
1.24
1.24
1.25
1.26
1.25
1.25
1.25
1.26
1.28

Total
System
KW**

85 (29.4)

85 (29.4)

15.93
14.89
12.09
12.64
10.28
16.66
15.99
12.90
13.51
10.79
17.28
17.31
13.67
14.33
11.27

Sens‡

21.36
22.02
22.45
24.33
26.88
22.28
22.55
22.92
24.87
27.33
23.03
23.07
23.29
25.26
27.68

Total
21.36
20.23
16.42
17.13
13.86
22.28
21.65
17.47
18.26
14.48
23.03
23.07
18.48
19.31
15.06

Sens‡

Capacity MBtuh

15.93
16.38
16.71
18.18
20.17
16.66
16.83
17.09
18.59
20.56
17.28
17.31
17.39
18.91
20.86

Total

Capacity MBtuh

DETAILED COOLING CAPACITIES#

1.70
1.70
1.70
1.73
1.79
1.72
1.72
1.71
1.77
1.80
1.75
1.75
1.73
1.79
1.82

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
25HCD324(A,W)**30 Outdoor Section With FB4CNF024 Indoor Section
1.82
20.01
20.01
2.01
18.55
18.55
2.25
1.83
20.58
19.52
2.03
18.58
18.58
2.25
1.83
21.09
15.82
2.05
18.86
14.86
2.25
1.86
22.96
16.57
2.09
21.15
15.84
2.32
1.91
25.54
13.37
2.14
23.99
12.83
2.40
1.86
21.18
21.18
2.08
19.52
19.52
2.29
1.86
21.23
21.23
2.08
19.55
19.55
2.29
1.87
21.53
16.86
2.08
19.35
15.93
2.29
1.90
23.40
17.68
2.13
21.78
17.03
2.37
1.94
25.98
14.01
2.17
24.43
13.49
2.43
1.89
21.91
21.91
2.12
20.37
20.37
2.34
1.89
21.94
21.94
2.12
20.40
20.40
2.34
1.90
21.88
17.87
2.12
19.70
16.93
2.32
1.93
23.76
18.77
2.16
22.10
18.10
2.41
1.97
26.31
14.61
2.20
24.75
14.11
2.46

25HCD318(A,W)**30 Outdoor Section With FB4CNF018 Indoor Section
1.37
14.83
14.83
1.52
13.70
13.70
1.37
15.05
14.24
1.52
13.73
13.73
1.38
15.42
11.53
1.53
13.80
10.84
1.39
17.04
12.18
1.56
15.53
11.58
1.41
19.02
9.88
1.59
17.68
9.38
1.39
15.79
15.79
1.56
14.44
14.44
1.39
15.81
15.81
1.56
14.46
14.46
1.39
15.97
12.42
1.56
14.16
11.66
1.41
17.40
13.04
1.58
16.09
12.53
1.43
19.41
10.41
1.61
18.06
9.95
1.41
16.38
16.38
1.58
15.09
15.09
1.41
16.41
16.41
1.58
15.12
15.12
1.41
16.24
13.18
1.58
14.48
12.44
1.42
17.69
13.87
1.60
16.35
13.35
1.44
19.69
10.90
1.62
18.34
10.46

Total
System
KW**

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
115 (46.1)

115 (46.1)

12.53
12.55
10.17
10.89
8.82
13.17
13.20
10.97
11.76
9.40
13.73
13.75
11.70
12.58
9.90

Sens‡

17.03
17.06
16.76
18.89
22.07
17.86
17.89
17.13
19.36
22.48
18.61
18.64
17.49
19.74
22.87

Total

17.03
17.06
13.96
14.94
12.12
17.86
17.89
14.97
16.08
12.81
18.61
18.64
15.95
17.16
13.52

Sens‡

Capacity MBtuh

12.53
12.55
12.20
13.75
16.09
13.17
13.20
12.51
14.10
16.50
13.73
13.75
12.78
14.38
16.73

Total

Capacity MBtuh

25HCD3

2.51
2.51
2.50
2.55
2.68
2.55
2.55
2.54
2.59
2.71
2.60
2.60
2.57
2.63
2.74

Total
System
KW**

1.90
1.90
1.89
1.92
1.99
1.92
1.92
1.91
1.94
2.02
1.94
1.95
1.93
1.96
2.04

Total
System
KW**

125 (51.7)

125 (51.7)

11.26
11.28
9.46
10.20
8.12
11.83
11.85
10.19
11.03
8.68
12.32
12.34
11.09
11.79
9.20

Sens‡

15.40
15.42
14.55
16.55
19.47
16.14
16.17
14.90
16.93
19.90
16.76
16.81
15.23
17.27
20.25

Total

15.40
15.42
13.00
14.01
11.20
16.14
16.17
13.98
15.10
11.92
16.76
16.81
14.83
16.11
12.62

Sens‡

Capacity MBtuh

11.26
11.28
10.50
11.97
14.07
11.83
11.85
10.78
12.26
14.39
12.32
12.34
11.09
12.51
14.63

Total

Capacity MBtuh

2.81
2.81
2.79
2.83
2.92
2.85
2.85
2.82
2.87
2.97
2.89
2.89
2.85
2.90
3.01

Total
System
KW**

2.13
2.13
2.11
2.14
2.19
2.15
2.15
2.13
2.16
2.21
2.17
2.17
2.15
2.18
2.23

Total
System
KW**

15

57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)

EWB
° F (° C)

57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)

See notes on page 17

1350

1200

1050

CFM

EWB
° F (° C)

EVAPORATOR AIR

1125

1000

875

CFM

EVAPORATOR AIR

75 (23.9)

27.18
24.01
19.61
20.43
16.62
28.38
25.72
20.82
21.66
17.30
29.38
27.27
21.97
22.83
17.95

Sens‡

31.95
33.18
33.87
36.68
40.08
33.27
33.98
34.60
37.41
40.70
34.39
34.71
35.21
37.95
41.12

Total

31.95
28.52
23.22
24.14
19.42
33.27
30.51
24.67
25.60
20.22
34.39
32.24
26.05
26.97
20.88

Sens‡

Capacity MBtuh

27.18
28.44
29.05
31.49
34.60
28.38
29.14
29.71
32.16
35.21
29.38
29.75
30.21
32.67
35.66

Total

Capacity MBtuh

75 (23.9)

2.39
2.41
2.42
2.44
2.48
2.45
2.46
2.47
2.49
2.53
2.51
2.51
2.52
2.54
2.57

Total
System
KW**

2.02
2.03
2.04
2.07
2.11
2.07
2.08
2.08
2.11
2.15
2.12
2.12
2.12
2.15
2.19

Total
System
KW**

85 (29.4)

26.03
23.33
18.95
19.77
16.06
27.13
24.98
20.14
21.06
16.78
28.07
28.15
21.28
22.26
17.45

Sens‡

30.67
31.56
32.19
34.92
38.56
31.91
32.31
32.85
35.66
39.19
32.97
33.03
33.35
36.17
39.64

Total
30.67
27.77
22.50
23.49
18.94
31.91
29.67
23.94
25.04
19.78
32.97
33.03
25.30
26.43
20.53

Sens‡

Capacity MBtuh

26.03
26.96
27.50
29.83
33.02
27.13
27.59
28.09
30.48
33.61
28.07
28.15
28.53
30.96
34.05

Total

Capacity MBtuh

85 (29.4)

25HCD336(A,W)**31 Outdoor Section With FB4CNF036 Indoor Section
2.65
29.29
29.29
2.94
27.80
27.80
2.66
29.84
26.94
2.95
28.01
26.01
2.67
30.39
21.74
2.95
28.45
20.94
2.71
32.98
22.73
3.00
30.94
21.95
2.75
36.71
18.31
3.04
34.58
17.59
2.71
30.46
30.46
3.00
28.89
28.89
2.72
30.54
30.54
3.00
28.93
28.93
2.72
30.97
23.16
3.01
28.97
22.34
2.76
33.60
24.27
3.05
31.47
23.46
2.79
37.34
19.19
3.09
35.20
18.50
2.77
31.42
31.42
3.06
29.79
29.79
2.77
31.46
31.46
3.06
29.82
29.82
2.77
31.40
24.50
3.06
29.36
23.65
2.81
34.08
25.72
3.10
31.88
24.88
2.84
37.79
20.00
3.14
35.64
19.34

Total
System
KW**

115 (46.1)

115 (46.1)

21.45
21.48
16.47
17.56
13.94
22.72
22.76
17.68
18.80
14.76
23.48
23.51
18.90
19.98
15.49

Sens‡

25.76
25.81
25.81
28.72
32.09
27.12
27.16
26.70
29.19
32.76
27.97
28.01
27.07
29.55
33.18

Total

25.76
25.81
19.85
21.10
16.72
27.12
27.16
21.41
22.59
17.71
27.97
28.01
22.70
23.99
18.58

Sens‡

Capacity MBtuh

21.45
21.48
21.55
24.14
26.97
22.72
22.76
22.11
24.55
27.51
23.48
23.51
22.76
24.86
27.89

Total

Capacity MBtuh

25HCD3

3.26
3.27
3.28
3.32
3.38
3.33
3.33
3.33
3.38
3.43
3.39
3.39
3.38
3.43
3.48

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
25HCD330(A,W)**30 Outdoor Section With FB4CNF030 Indoor Section
2.24
24.78
24.78
2.50
23.39
23.39
2.79
2.25
25.36
22.59
2.51
23.65
21.76
2.79
2.26
25.87
18.25
2.52
24.07
17.50
2.80
2.30
28.06
19.07
2.55
26.17
18.34
2.85
2.34
31.22
15.43
2.60
29.22
14.74
2.91
2.29
25.81
25.81
2.55
24.36
24.36
2.85
2.30
25.98
24.14
2.55
24.40
24.40
2.85
2.30
26.36
19.42
2.56
24.52
18.67
2.85
2.34
28.60
20.33
2.60
26.61
19.58
2.89
2.38
31.78
16.17
2.65
29.75
15.50
2.95
2.34
26.66
26.66
2.60
25.15
25.15
2.90
2.34
26.70
26.70
2.60
25.18
25.18
2.90
2.35
26.75
20.55
2.60
24.84
19.77
2.89
2.38
29.01
21.55
2.64
26.97
20.78
2.94
2.42
32.19
16.87
2.69
30.14
16.21
2.99

DETAILED COOLING CAPACITIES# CONTINUED

3.59
3.60
3.59
3.70
3.77
3.70
3.70
3.69
3.75
3.82
3.77
3.77
3.74
3.81
3.87

Total
System
KW**

3.07
3.07
3.07
3.17
3.25
3.17
3.17
3.13
3.22
3.29
3.23
3.23
3.20
3.27
3.33

Total
System
KW**

125 (51.7)

125 (51.7)

19.49
19.54
15.40
16.53
13.15
20.47
20.51
16.54
17.83
13.90
21.30
21.34
17.60
19.05
14.64

Sens‡

23.48
23.53
22.68
25.84
29.53
24.64
24.68
23.25
26.62
29.95
25.68
25.72
23.69
26.96
30.35

Total

23.48
23.53
18.58
20.01
15.84
24.64
24.68
19.97
21.61
16.76
25.68
25.72
21.22
22.97
17.66

Sens‡

Capacity MBtuh

19.49
19.54
18.91
21.41
24.63
20.47
20.51
19.33
21.98
25.00
21.30
21.34
19.71
22.48
25.30

Total

Capacity MBtuh

3.99
3.99
3.97
4.06
4.21
4.06
4.07
4.02
4.16
4.27
4.15
4.16
4.08
4.22
4.31

Total
System
KW**

3.42
3.42
3.40
3.49
3.63
3.49
3.49
3.45
3.56
3.68
3.56
3.56
3.50
3.63
3.72

Total
System
KW**

16

57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)

EWB
° F (° C)

57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)

See notes on page 17

1800

1600

1400

CFM

EWB
° F (° C)

EVAPORATOR AIR

1575

1400

1225

CFM

EVAPORATOR AIR

75 (23.9)

39.37
37.19
30.35
31.55
25.53
41.05
39.81
32.24
33.45
26.60
42.49
42.10
34.03
35.20
27.56

Sens‡

44.84
46.76
47.74
51.68
56.56
46.75
47.86
48.79
52.69
57.44
48.37
48.85
49.60
53.47
58.09

Total

44.84
41.67
33.97
35.32
28.54
46.75
44.58
36.07
37.40
29.66
48.37
47.20
38.01
39.41
30.71

Sens‡

Capacity MBtuh

39.37
41.08
41.94
45.43
49.74
41.05
42.10
42.91
46.38
50.61
42.49
43.00
43.68
47.08
51.25

Total

Capacity MBtuh

75 (23.9)

3.32
3.34
3.34
3.36
3.38
3.40
3.40
3.41
3.43
3.45
3.47
3.47
3.47
3.49
3.52

Total
System
KW**

3.01
3.01
3.01
2.98
2.94
3.05
3.05
3.04
3.02
2.98
3.09
3.09
3.08
3.05
3.02

Total
System
KW**

85 (29.4)

37.75
36.16
29.36
30.64
24.77
39.30
38.67
31.23
32.65
25.87
40.64
40.76
33.00
34.43
26.89

Sens‡

42.92
44.30
45.20
48.96
54.12
44.70
45.34
46.10
50.00
55.02
46.18
46.29
46.81
50.73
55.69

Total
42.92
40.49
32.83
34.23
27.70
44.70
43.30
34.88
36.46
28.92
46.18
46.29
36.86
38.51
30.04

Sens‡

Capacity MBtuh

37.75
38.99
39.77
43.16
47.65
39.30
39.92
40.63
44.09
48.50
40.64
40.76
41.28
44.76
49.14

Total

Capacity MBtuh

85 (29.4)

25HCD348(A,W)**31 Outdoor Section With FB4CNF048 Indoor Section
3.70
40.93
40.93
4.11
38.86
38.86
3.72
41.77
39.25
4.12
39.24
37.92
3.73
42.56
31.66
4.13
39.87
30.49
3.77
46.17
33.09
4.19
43.26
31.91
3.82
51.31
26.67
4.26
48.25
25.56
3.78
42.55
42.55
4.20
40.36
40.36
3.79
42.77
42.42
4.20
40.41
40.41
3.80
43.34
33.68
4.21
40.55
32.48
3.84
47.00
35.27
4.27
43.99
34.06
3.89
52.17
27.93
4.33
49.07
26.85
3.87
43.93
43.93
4.29
41.59
41.59
3.87
43.99
43.99
4.29
41.64
41.64
3.87
43.97
35.64
4.28
41.05
34.39
3.91
47.66
37.39
4.34
44.54
36.15
3.95
52.82
29.12
4.40
49.68
28.08

Total
System
KW**

4.55
4.56
4.57
4.64
4.72
4.65
4.65
4.65
4.73
4.80
4.74
4.74
4.73
4.80
4.87

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
25HCD342(A,W)**31 Outdoor Section With FB4CNF042 Indoor Section
3.34
36.03
36.03
3.69
34.20
34.20
4.07
3.34
36.82
35.06
3.70
34.58
33.87
4.08
3.34
37.53
28.35
3.70
35.15
27.30
4.09
3.34
40.70
29.62
3.72
38.18
28.58
4.12
3.32
45.25
23.90
3.72
42.59
22.96
4.15
3.39
37.49
37.49
3.75
35.56
35.56
4.14
3.39
37.73
37.39
3.75
35.61
35.61
4.14
3.39
38.26
30.19
3.75
35.81
29.11
4.14
3.38
41.50
31.60
3.77
38.83
30.53
4.18
3.36
46.07
25.05
3.76
43.36
24.14
4.20
3.44
38.70
38.70
3.80
36.67
36.67
4.20
3.44
38.75
38.75
3.80
36.71
36.71
4.20
3.44
38.83
31.93
3.80
36.30
30.82
4.20
3.42
42.12
33.50
3.82
39.37
32.39
4.23
3.39
46.67
26.10
3.81
43.93
25.24
4.25

DETAILED COOLING CAPACITIES# CONTINUED
115 (46.1)

115 (46.1)

31.58
31.64
25.83
27.48
21.82
33.40
33.44
27.77
29.42
23.11
34.47
34.51
29.59
31.23
24.23

Sens‡

36.60
36.66
36.99
40.24
45.02
38.00
38.05
37.59
40.86
45.76
39.13
39.18
38.05
41.34
46.32

Total

36.60
36.66
29.25
30.71
24.40
38.00
38.05
31.21
32.83
25.71
39.13
39.18
33.09
34.87
26.95

Sens‡

Capacity MBtuh

31.58
31.64
31.79
35.48
39.57
33.40
33.44
32.72
36.08
40.38
34.47
34.51
33.52
36.51
40.90

Total

Capacity MBtuh

25HCD3

5.05
5.06
5.06
5.14
5.24
5.16
5.16
5.14
5.22
5.31
5.25
5.25
5.22
5.30
5.38

Total
System
KW**

4.44
4.44
4.45
4.56
4.63
4.57
4.57
4.53
4.62
4.68
4.64
4.64
4.62
4.68
4.73

Total
System
KW**

125 (51.7)

125 (51.7)

28.93
28.98
24.25
26.05
20.70
30.34
30.39
26.06
28.16
21.88
31.57
31.63
27.70
29.94
23.06

Sens‡

33.56
33.63
32.84
37.01
41.51
35.38
35.43
33.69
37.56
42.25
36.47
36.52
34.69
37.99
42.74

Total

33.56
33.63
27.47
29.42
23.12
35.38
35.43
29.53
31.51
24.50
36.47
36.52
31.59
33.50
25.74

Sens‡

Capacity MBtuh

28.93
28.98
28.16
31.93
36.47
30.34
30.39
28.86
32.97
37.02
31.57
31.63
29.39
33.42
37.53

Total

Capacity MBtuh

5.57
5.57
5.54
5.71
5.82
5.73
5.73
5.64
5.79
5.89
5.83
5.83
5.77
5.87
5.96

Total
System
KW**

4.89
4.89
4.86
4.98
5.14
4.98
4.98
4.93
5.09
5.20
5.07
5.07
5.00
5.16
5.25

Total
System
KW**

17

57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)
57 (13.9)
62 (16.7)
63 (17.2)††
67 (19.4)
72 (22.2)

EWB
° F (° C)

57.16
59.15
60.11
64.72
71.01
59.49
60.51
61.25
65.90
72.25
61.41
61.74
62.12
66.78
73.16

Total

57.16
52.45
42.61
44.22
35.89
59.49
56.18
45.11
46.91
37.51
61.41
59.59
47.48
49.46
39.03

Sens‡

Capacity MBtuh

75 (23.9)

4.38
4.41
4.42
4.47
4.55
4.50
4.51
4.52
4.58
4.66
4.61
4.62
4.62
4.68
4.76

Total
System
KW**
54.99
56.47
57.31
61.70
67.67
57.16
57.75
58.34
62.75
68.77
58.94
58.94
59.10
63.51
69.54

Total
54.99
51.18
41.34
42.95
34.62
57.16
54.84
43.82
45.62
36.22
58.94
58.94
46.18
48.15
37.71

Sens‡

Capacity MBtuh

85 (29.4)

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
25HCD360(A,W)**30 Outdoor Section With FY5BNB060 Indoor Section
4.83
52.69
52.69
5.33
50.18
50.18
5.91
4.85
53.63
49.82
5.35
50.65
48.37
5.92
4.86
54.35
40.02
5.36
51.18
38.61
5.92
4.92
58.50
41.62
5.42
55.07
40.20
5.98
5.00
64.16
33.30
5.50
60.39
31.90
6.07
4.95
54.68
54.68
5.45
52.00
52.00
6.03
4.96
54.89
53.32
5.46
52.07
52.07
6.03
4.96
55.23
42.47
5.46
51.97
41.05
6.02
5.02
59.40
44.26
5.52
55.83
42.82
6.08
5.11
65.08
34.87
5.61
61.18
33.45
6.17
5.06
56.30
56.30
5.57
53.46
53.46
6.14
5.06
56.37
56.37
5.57
53.52
53.52
6.14
5.06
55.93
44.82
5.56
52.55
43.38
6.12
5.12
60.08
46.79
5.62
56.44
45.35
6.19
5.21
65.76
36.35
5.71
61.72
34.91
6.27
115 (46.1)

47.44
47.54
47.79
51.41
56.34
49.06
49.12
48.46
52.07
56.96
50.35
50.39
48.95
52.54
57.39

Total
47.44
47.30
37.14
38.74
30.42
49.06
49.12
39.57
41.35
31.94
50.35
50.39
41.84
43.80
33.38

Sens‡

Capacity MBtuh

6.57
6.57
6.57
6.63
6.71
6.69
6.69
6.68
6.73
6.81
6.80
6.80
6.77
6.83
6.91

Total
System
KW**

125 (51.7)

44.45
44.51
44.16
47.49
52.00
45.86
45.91
44.70
48.02
52.49
46.98
47.03
45.12
48.41
52.81

Total

44.45
44.51
35.59
37.18
28.86
45.86
45.91
37.96
39.75
30.36
46.98
47.03
40.18
42.16
31.78

Sens‡

Capacity MBtuh

7.32
7.32
7.32
7.36
7.44
7.43
7.43
7.41
7.46
7.54
7.54
7.54
7.51
7.56
7.63

Total
System
KW**

25HCD3

* Tested combination.
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C).
# Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240 ---2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may
occur.
** System kw is total of indoor and outdoor unit kilowatts.
{{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb.
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
EWB — Entering Wet Bulb

2250

2000

1750

CFM

EVAPORATOR AIR

DETAILED COOLING CAPACITIES# CONTINUED

18

5.26

5.33

4.93

5.01

5.08

4.64

4.73

4.80

675

525

600

675

525

600

675

7.98

8.15

8.29

7.54

7.71

7.85

7.08

7.24

7.38

800

900

700

800

900

700

800

900

Total

700

CFM

---3 (19.4)

4.42

4.35

4.27

4.67

4.61

4.53

4.91

4.84

4.76

Integ*

6.79

6.66

6.51

7.22

7.09

6.94

7.63

7.50

7.35

Integ

Capacity MBtuh

5.18

600

Total

See notes on page 21

75
(23.9)

70
(21.1)

65
(18.3)

EDB
° F (° C)

---3 ( ---19.4)

Capacity MBtuh

525

CFM

INDOOR AIR

75
(23.9)

70
(21.1)

65
(18.3)

EDB
° F (° C)

INDOOR AIR

1.60

1.59

1.58

1.53

1.52

1.51

1.47

1.46

1.45

Total
System
KW

1.20

1.19

1.19

1.15

1.14

1.14

1.10

1.09

1.09

Total
Syst.
KW†

7 ( ---13.9)

6.38

6.30

6.20

6.63

6.55

6.45

6.87

6.78

6.69

Integ*

10.03

9.86

9.68

10.49

10.32

10.14

10.91

10.74

10.55

Total

9.22

9.06

8.89

9.64

9.49

9.31

10.02

9.87

9.70

Integ

Capacity MBtuh

6.94

6.85

6.74

7.22

7.13

7.02

7.47

7.38

7.28

Total

Capacity MBtuh

7 ( ---13.9)

1.69

1.68

1.68

1.62

1.61

1.61

1.55

1.54

1.54

Total
System
KW

1.24

1.24

1.24

1.19

1.19

1.19

1.13

1.13

1.13

Total
Syst.
KW†

HEAT PUMP HEATING PERFORMANCE

12.76

12.57

12.36

13.19

13.00

12.78

13.60

13.42

13.20

Total

Total
Syst.
KW†

Capacity MBtuh

27 ( ---2.8)
Total
Syst.
KW†

Capacity MBtuh

37 (2.8)

17 ( ---8.3)

8.41

8.30

8.18

8.68

8.57

8.44

9.11

8.87

8.71

10.51

10.40

10.27

10.71

10.61

10.48

10.91

10.81

10.68

1.33

1.34

1.36

1.27

1.28

1.29

1.20

1.21

1.23

14.25

14.10

13.92

14.51

14.36

14.18

14.77

14.62

14.44

12.96

12.83

12.67

13.21

13.07

12.91

13.44

13.31

13.14

11.63

11.46

11.27

12.03

11.85

11.66

12.40

12.23

12.03

1.75

1.75

1.75

1.67

1.67

1.67

1.60

1.60

1.60

1.37

1.39

1.41

1.31

1.32

1.35

1.25

1.26

1.28

Total

Integ

Capacity MBtuh

27 ( ---2.i8)
Total
System
KW
Total

Integ

Capacity MBtuh

37 (2.8)

15.68

15.45

15.19

16.26

15.96

15.64

16.82

16.65

16.25

13.92

13.73

13.49

14.44

14.18

13.89

14.94

14.78

14.43

1.80

1.81

1.82

1.72

1.73

1.74

1.65

1.65

1.67

18.99

18.81

18.59

19.29

19.08

18.85

19.58

19.39

19.15

17.28

17.11

16.91

17.55

17.36

17.15

17.82

17.64

17.43

1.87

1.88

1.91

1.78

1.79

1.82

1.69

1.70

1.73

Total
System
KW

OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)

11.83

11.72

11.57

12.06

11.95

11.80

12.28

12.17

12.03

25HCD324(A,W)**30 Outdoor Section With FB4CNF024 Indoor Section

Integ

Total
System
KW

1.28

1.29

1.29

1.23

1.23

1.24

1.17

1.17

1.18

Total
Syst.
KW†

OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)

InInInTotal
Total
teg*
teg*
teg*
25HCD318(A,W)**30 Outdoor Section With FB4CNF018 Indoor Section

Capacity MBtuh

9.22

9.11

8.97

9.52

9.40

9.26

10.00

9.73

9.55

Total

Capacity MBtuh

17 ( ---8.3)

47 (8.3)

16.64

16.59

16.49

16.81

16.80

16.72

16.95

16.98

16.94

Integ*

21.90

21.66

21.39

22.24

22.00

21.72

22.59

22.34

22.05

Total

21.90

21.66

21.39

22.24

22.00

21.72

22.59

22.34

22.05

Integ

Capacity MBtuh

16.64

16.59

16.49

16.81

16.80

16.72

16.95

16.98

16.94

Total

Capacity MBtuh

47 (8.3)

25HCD3

1.92

1.95

1.98

1.83

1.85

1.89

1.74

1.76

1.80

Total
System
KW

1.41

1.44

1.48

1.34

1.37

1.40

1.27

1.30

1.33

Total
Syst.
KW†

57 (13.9)

57 (13.9)

18.48

18.57

18.58

18.58

18.74

18.81

18.64

18.87

19.01

Integ*

25.11

24.91

24.61

25.44

25.27

24.99

25.74

25.60

25.36

Total

25.11

24.91

24.61

25.44

25.27

24.99

25.74

25.60

25.36

Integ

Capacity MBtuh

18.48

18.57

18.58

18.58

18.74

18.81

18.64

18.87

19.01

Total

Capacity MBtuh

1.99

2.02

2.08

1.89

1.93

1.98

1.80

1.83

1.89

Total
System
KW

1.45

1.48

1.53

1.37

1.41

1.45

1.30

1.34

1.38

Total
Syst.
KW†

67 (19.4)

67 (19.4)

19.85

20.12

20.34

19.88

20.27

20.55

19.82

20.34

20.73

Integ*

27.65

27.62

27.51

27.94

27.95

27.87

28.20

28.25

28.21

Total

27.65

27.62

27.51

27.94

27.95

27.87

28.20

28.25

28.21

Integ

Capacity MBtuh

19.85

20.12

20.34

19.88

20.27

20.55

19.82

20.34

20.73

Total

Capacity MBtuh

2.06

2.10

2.17

1.96

2.00

2.07

1.86

1.91

1.97

Total
System
KW

1.47

1.51

1.57

1.40

1.44

1.50

1.32

1.36

1.42

Total
Syst.
KW†

19

875
1000
1125
875
1000
1125
875
1000
1125

CFM

1050
1200
1350
1050
1200
1350
1050
1200
1350

CFM

---3 ( ---19.4)

--- 3 (19.4)

10.62
10.79
10.95
10.20
10.40
10.56
9.81
9.98
10.14

Integ*

12.79
13.08
13.35
11.97
12.30
12.56
11.18
11.45
11.71

Total

11.77
12.04
12.28
11.01
11.31
11.55
10.29
10.53
10.78

Integ

Capacity MBtuh

11.54
11.73
11.90
11.08
11.30
11.48
10.66
10.85
11.02

Total

Capacity MBtuh

See notes on page 21

75
(23.9)

70
(21.1)

65
(18.3)

EDB
° F (° C)

INDOOR AIR

75
(23.9)

70
(21.1)

65
(18.3)

EDB
° F (° C)

INDOOR AIR

2.17
2.19
2.22
2.27
2.29
2.32
2.37
2.40
2.43

Total
System
KW

2.01
2.02
2.04
2.10
2.11
2.13
2.20
2.21
2.22

Total
Syst.
KW†

7 (--- 13.9)

13.43
13.63
13.81
13.02
13.24
13.42
12.63
12.83
13.01

Integ*

16.58
16.92
17.22
15.80
16.16
16.46
15.04
15.37
15.67

Total
15.24
15.55
15.83
14.52
14.85
15.13
13.83
14.13
14.40

Integ

Capacity MBtuh

14.61
14.83
15.02
14.17
14.41
14.61
13.74
13.97
14.16

Total

Capacity MBtuh

7 ( ---13.9)

2.26
2.28
2.30
2.36
2.38
2.40
2.47
2.48
2.51

Total
System
KW

2.07
2.07
2.08
2.16
2.17
2.18
2.26
2.26
2.27

Total
Syst.
KW†
Integ*

Total

Integ*

Total

Integ*

17 (--- 8.3)

47 (8.3)

33.44
33.84
34.23
32.95
33.40
33.76
32.46
32.89
33.26

Integ

25HCD3

33.44
33.84
34.23
32.95
33.40
33.76
32.46
32.89
33.26

Total

Capacity MBtuh

47 (8.3)

28.66
29.04
29.36
28.23
28.60
28.91
27.80
28.16
28.47

Integ*

Capacity MBtuh

28.66
29.04
29.36
28.23
28.60
28.91
27.80
28.16
28.47

37 (2.8)
Capacity MBtuh

25HCD330(A,W)**30 Outdoor Section With FB4CNF030 Indoor Section
16.31
2.13
21.51
19.10
2.20
24.95
22.71
2.26
16.58
2.12
21.76
19.32
2.18
25.26
22.99
2.23
17.06
2.13
21.96
19.50
2.17
25.52
23.22
2.21
15.90
2.22
21.21
18.84
2.30
24.58
22.37
2.36
16.14
2.22
21.45
19.05
2.28
24.88
22.64
2.33
16.35
2.22
21.65
19.23
2.27
25.13
22.87
2.32
15.49
2.32
20.87
18.54
2.41
24.20
22.03
2.48
15.73
2.32
21.12
18.76
2.39
24.49
22.29
2.44
15.93
2.32
21.33
18.95
2.38
24.75
22.52
2.43

Total
Syst.
KW†
Total

27 ( ---2.8)
Capacity MBtuh

OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
27 (--- 2.i8)
37 (2.8)
Total
Total
Total
Capacity MBCapacity MBCapacity MBSysSysSystuh
tuh
tuh
tem
tem
tem
Total
Integ
Total
Integ
Total
Integ
KW
KW
KW
25HCD336(A,W)**31 Outdoor Section With FB4CNF036 Indoor Section
20.53
18.72
2.35
24.72
21.96
2.46
29.59
26.93
2.60
20.91
19.07
2.36
25.18
22.36
2.46
29.99
27.29
2.58
21.25
19.37
2.37
25.56
22.70
2.46
30.31
27.58
2.58
19.79
18.04
2.46
24.01
21.32
2.57
29.06
26.45
2.72
20.20
18.42
2.47
24.46
21.72
2.56
29.49
26.84
2.70
20.53
18.72
2.48
24.83
22.06
2.57
29.84
27.16
2.69
19.07
17.39
2.57
23.26
20.66
2.68
27.74
25.24
2.81
19.45
17.73
2.57
23.71
21.06
2.67
28.43
25.87
2.79
19.78
18.04
2.59
24.08
21.39
2.68
29.29
26.66
2.81

17.89
18.18
18.71
17.44
17.70
17.93
16.99
17.25
17.47

Total

Total
Syst.
KW†

OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
Total
Syst.
KW†

Capacity MBtuh

17 ( ---8.3)

HEAT PUMP HEATING PERFORMANCE CONTINUED

2.71
2.68
2.66
2.83
2.80
2.78
2.96
2.92
2.90

Total
System
KW

2.33
2.29
2.27
2.44
2.39
2.37
2.55
2.50
2.48

Total
Syst.
KW†

57 (13.9)

57 (13.9)

32.91
33.14
33.18
32.45
32.74
32.84
31.99
32.32
32.48

Integ*

37.48
38.05
38.53
36.89
37.45
37.92
36.32
36.86
37.31

Total

37.48
38.05
38.53
36.89
37.45
37.92
36.32
36.86
37.31

Integ

Capacity MBtuh

32.91
33.14
33.18
32.45
32.74
32.84
31.99
32.32
32.48

Total

Capacity MBtuh

2.84
2.80
2.77
2.97
2.92
2.89
3.10
3.05
3.02

Total
System
KW

2.40
2.34
2.30
2.51
2.45
2.41
2.63
2.56
2.52

Total
Syst.
KW†

67 (19.4)

67 (19.4)

36.28
36.10
35.81
35.92
35.79
35.55
35.52
35.45
35.27

Integ*

41.96
42.68
43.26
41.27
41.97
42.56
40.58
41.27
41.84

Total

41.96
42.68
43.26
41.27
41.97
42.56
40.58
41.27
41.84

Integ

Capacity MBtuh

36.28
36.10
35.81
35.92
35.79
35.55
35.52
35.45
35.27

Total

Capacity MBtuh

3.04
2.97
2.93
3.17
3.10
3.06
3.31
3.24
3.19

Total
System
KW

2.45
2.37
2.32
2.57
2.49
2.43
2.69
2.60
2.55

Total
Syst.
KW†

20

1225
1400
1525
1225
1400
1525
1225
1400
1525

CFM

1400
1600
1800
1400
1600
1800
1400
1600
1800

CFM

---3 ( ---19.4)

--- 3 (19.4)

14.35
14.69
14.87
13.68
13.97
14.10
12.91
13.20
13.38

Integ*

18.42
18.80
19.15
17.61
17.99
18.34
16.74
17.12
17.47

Total

16.95
17.30
17.61
16.20
16.55
16.87
15.40
15.75
16.07

Integ

Capacity MBtuh

15.60
15.96
16.17
14.87
15.18
15.33
14.04
14.34
14.55

Total

Capacity MBtuh

See notes on page 21

75
(23.9)

70
(21.1)

65
(18.3)

EDB
° F (° C)

INDOOR AIR

75
(23.9)

70
(21.1)

65
(18.3)

EDB
° F (° C)

INDOOR AIR

3.14
3.19
3.24
3.27
3.31
3.36
3.41
3.45
3.50

Total
System
KW

2.64
2.66
2.68
2.80
2.82
2.84
2.96
2.99
3.01

Total
Syst.
KW†

7 (--- 13.9)

18.54
18.86
19.07
17.83
18.16
18.37
17.10
17.42
17.63

Integ*

23.65
24.10
24.47
22.86
23.30
23.68
22.00
22.44
22.83

Total
21.74
22.15
22.49
21.00
21.41
21.76
20.22
20.62
20.98

Integ

Capacity MBtuh

20.17
20.52
20.75
19.40
19.76
20.00
18.60
18.96
19.19

Total

Capacity MBtuh

7 ( ---13.9)

3.21
3.24
3.28
3.34
3.37
3.41
3.48
3.51
3.55

Total
System
KW

2.75
2.76
2.77
2.88
2.90
2.91
3.03
3.04
3.05

Total
Syst.
KW†

27 ( ---2.8)
Total

Integ*

Capacity MBtuh
Total
Syst.
KW†

37 (2.8)
Total

Integ*

Capacity MBtuh
Total
Syst.
KW†

25HCD342(A,W)**31 Outdoor Section With FB4CNF042 Indoor Section
22.55
2.85
29.47
26.17
2.95
34.77
31.64
3.05
22.93
2.85
29.96
26.61
2.94
35.16
32.00
3.03
23.17
2.86
30.27
26.89
2.94
35.42
32.23
3.02
21.87
2.97
28.70
25.49
3.06
34.24
31.16
3.17
22.25
2.98
29.18
25.91
3.06
34.67
31.55
3.15
22.49
2.99
29.49
26.19
3.06
34.94
31.79
3.14
21.16
3.11
27.91
24.79
3.19
32.98
30.01
3.28
21.53
3.11
28.39
25.21
3.18
34.12
31.05
3.28
21.77
3.12
28.69
25.48
3.18
34.39
31.29
3.27

Integ*

Total
Syst.
KW†

OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)

17 (--- 8.3)

OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
27 (--- 2.i8)
37 (2.8)
Total
Total
Total
Capacity MBCapacity MBCapacity MBSysSysSystuh
tuh
tuh
tem
tem
tem
Total
Integ
Total
Integ
Total
Integ
KW
KW
KW
25HCD348(A,W)**31 Outdoor Section With FB4CNF048 Indoor Section
28.90
26.35
3.28
35.25
31.31
3.40
40.02
36.42
3.48
29.38
26.79
3.30
35.74
31.74
3.40
40.52
36.87
3.46
29.81
27.18
3.33
36.14
32.10
3.41
40.97
37.28
3.46
28.11
25.63
3.42
33.56
29.80
3.50
39.44
35.89
3.63
28.60
26.08
3.43
34.24
30.41
3.51
39.94
36.35
3.61
29.03
26.47
3.46
35.39
31.43
3.55
40.40
36.76
3.61
27.27
24.87
3.56
32.66
29.01
3.65
38.91
35.41
3.79
27.77
25.32
3.57
33.25
29.53
3.65
39.42
35.87
3.77
28.20
25.71
3.60
33.75
29.98
3.66
39.83
36.24
3.77

24.73
25.15
25.41
23.98
24.40
24.66
23.21
23.61
23.88

Total

Capacity MBtuh

17 ( ---8.3)

HEAT PUMP HEATING PERFORMANCE CONTINUED

47 (8.3)

39.07
39.57
39.87
38.52
39.00
39.30
38.00
38.46
38.75

Integ*

45.07
45.69
46.22
44.40
45.00
45.52
43.75
44.33
44.84

Total

45.07
45.69
46.22
44.40
45.00
45.52
43.75
44.33
44.84

Integ

Capacity MBtuh

39.07
39.57
39.87
38.52
39.00
39.30
38.00
38.46
38.75

Total

Capacity MBtuh

47 (8.3)

25HCD3

3.56
3.53
3.52
3.71
3.68
3.67
3.87
3.84
3.83

Total
System
KW

3.08
3.05
3.04
3.21
3.17
3.16
3.34
3.30
3.29

Total
Syst.
KW†

57 (13.9)

57 (13.9)

43.89
44.52
44.90
43.24
43.85
44.23
42.60
43.19
43.56

Integ*

50.81
51.59
52.24
50.01
50.76
51.40
49.22
49.95
50.57

Total

50.81
51.59
52.24
50.01
50.76
51.40
49.22
49.95
50.57

Integ

Capacity MBtuh

43.89
44.52
44.90
43.24
43.85
44.23
42.60
43.19
43.56

Total

Capacity MBtuh

3.66
3.61
3.59
3.82
3.77
3.74
3.98
3.93
3.90

Total
System
KW

3.10
3.05
3.03
3.23
3.18
3.16
3.37
3.31
3.29

Total
Syst.
KW†

67 (19.4)

67 (19.4)

49.14
49.61
49.76
48.43
48.95
49.17
47.73
48.30
48.57

Integ*

57.16
58.17
58.97
56.20
57.15
58.01
55.27
56.19
57.03

Total

57.16
58.17
58.97
56.20
57.15
58.01
55.27
56.19
57.03

Integ

Capacity MBtuh

49.14
49.61
49.76
48.43
48.95
49.17
47.73
48.30
48.57

Total

Capacity MBtuh

3.81
3.72
3.66
3.97
3.90
3.83
4.15
4.07
4.01

Total
System
KW

3.09
3.01
2.97
3.23
3.15
3.11
3.38
3.29
3.25

Total
Syst.
KW†

21

1750
2000
2250
1750
2000
2250
1750
2000
2250

CFM

24.86
25.43
25.95
23.67
24.22
24.72
22.37
22.91
23.41

Total

22.87
23.40
23.87
21.78
22.28
22.74
20.58
21.08
21.54

Integ*

Capacity MBtuh

---3 ( ---19.4)

3.95
4.01
4.08
4.10
4.16
4.23
4.27
4.33
4.40

Total
Syst.
KW†

31.48
32.04
32.60
30.33
30.94
31.51
29.13
29.73
30.29

Total

28.93
29.45
29.95
27.87
28.43
28.95
26.77
27.32
27.84

Integ*

Capacity MBtuh

7 ( ---13.9)

4.06
4.10
4.16
4.22
4.27
4.32
4.39
4.44
4.50

Total
Syst.
KW†

38.08
38.76
39.33
37.00
37.68
38.28
35.90
36.57
37.15

Total

37 (2.8)

Integ*

Total

Integ*

Total

Integ*

Capacity MBtuh

47 (8.3)

58.88
59.73
60.46
58.00
58.81
59.54
57.17
57.93
58.63

Integ*

Capacity MBtuh

58.88
59.73
60.46
58.00
58.81
59.54
57.17
57.93
58.63

Total
Syst.
KW†

25HCD360(A,W)**30 Outdoor Section With FY5BNB060 Indoor Section
34.72
4.17
45.28
40.21
4.30
52.48
47.76
4.47
35.34
4.19
46.95
41.70
4.35
53.15
48.37
4.46
35.86
4.23
47.49
42.18
4.37
53.73
48.90
4.46
33.74
4.34
44.01
39.08
4.48
51.73
47.07
4.67
34.36
4.36
44.80
39.79
4.49
52.40
47.68
4.65
34.90
4.41
45.52
40.43
4.51
52.96
48.19
4.66
32.74
4.52
42.85
38.05
4.66
51.00
46.41
4.89
33.34
4.55
43.63
38.75
4.67
51.62
46.97
4.86
33.87
4.59
44.29
39.34
4.70
52.19
47.49
4.86

27 ( ---2.8)
Capacity MBtuh
Total

Total
Syst.
KW†

OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
Total
Syst.
KW†

Capacity MBtuh

17 ( ---8.3)

4.62
4.59
4.59
4.83
4.79
4.78
5.05
5.00
4.99

Total
Syst.
KW†

57 (13.9)

66.42
67.34
67.94
65.43
66.40
67.06
64.41
65.46
66.17

Total

66.42
67.34
67.94
65.43
66.40
67.06
64.41
65.46
66.17

Integ*

Capacity MBtuh

4.80
4.73
4.70
5.01
4.93
4.91
5.23
5.15
5.11

Total
Syst.
KW†

67 (19.4)

73.43
73.99
74.27
72.49
73.04
73.39
71.54
72.12
72.48

Total

73.43
73.99
74.27
72.49
73.04
73.39
71.54
72.12
72.48

Integ*

Capacity MBtuh

25HCD3

NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.
EDB — Entering Dry Bulb

75
(23.9)

70
(21.1)

65
(18.3)

EDB
° F (° C)

INDOOR AIR

HEAT PUMP HEATING PERFORMANCE CONTINUED

4.96
4.87
4.82
5.17
5.08
5.03
5.39
5.29
5.24

Total
Syst.
KW†

GUIDE SPECIFICATIONS
GENERAL
System Description

AIR--COOLED, SPLIT--SYSTEM HEAT PUMP
25HCD3
1--1/2 TO 5 NOMINAL TONS

Fans

Outdoor--mounted, air--cooled, split--system heat pump unit
suitable for ground or rooftop installation. Unit consists of a
hermetic compressor, an air--cooled coil, propeller--type condenser
fan, and a control box. Unit will discharge supply air upward as
shown on contract drawings. Unit will be used in a refrigeration
circuit to match up to a packaged fan coil or coil unit.

—
—

—
—
—

Quality Assurance
—
—

25HCD3

—
—

—

—
—

Unit will be rated in accordance with the latest edition of
AHRI Standard 240.
Unit will be certified for capacity and efficiency, and
listed in the latest AHRI directory.
Unit construction will comply with latest edition of
ANSI/ ASHRAE and with NEC.
Unit will be constructed in accordance with UL
standards and will carry the UL label of approval. Unit
will have C--UL approval.
Unit cabinet will be capable of withstanding Federal Test
Method Standard No. 141 (Method 6061) 500--hr salt
spray test.
Air--cooled condenser coils are pressure tested and the
outdoor unit is leak tested.
Unit constructed in ISO9001 approved facility.

Compressor
—
—

Unit will be shipped as single package only and is stored
and handled per unit manufacturer’s recommendations.

Warranty (for inclusion by specifying engineer)
—

—
—

—

—

U.S. and Canada only.

—

Factory assembled, single piece, air--cooled heat pump
unit. Contained within the unit enclosure is all factory
wiring, piping, controls, compressor, refrigerant charge
Puronr (R--410A), and special features required prior to
field start--up.

—

Unit Cabinet
—

Unit cabinet will be constructed of galvanized steel,
bonderized, and coated with a powder coat paint.
Available with dense grille only.

Refrigeration circuit components will include liquid--line
shutoff valve with sweat connections, vapor--line shutoff
valve with sweat connections, system charge of Puronr
(R--410A) refrigerant, POE compressor oil, accumulator,
and reversing valve.

Operating Characteristics

Equipment

—

Condenser coil will be air cooled.
Coil will be constructed of aluminum fins mechanically
bonded to copper tubes which are then cleaned,
dehydrated, and sealed.

Refrigeration Components

PRODUCTS
—

Compressor will be hermetically sealed.
Compressor will be mounted on rubber vibration
isolators.

Condenser Coil

Delivery, Storage, and Handling
—

Condenser fan will be direct--drive propeller type,
discharging air upward.
Condenser fan motors will be totally enclosed, 1--phase
type with class B insulation and permanently lubricated
bearings.
Shafts will be corrosion resistant.
Fan blades will be statically and dynamically balanced.
Condenser fan openings will be equipped with steel wire
safety guards.

The capacity of the unit will meet or exceed _____ Btuh
at a suction temperature of _____ _F/_C. The power
consumption at full load will not exceed _____ kW.
Combination of the unit and the evaporator or fan coil
unit will have a total net cooling capacity of _____ Btuh
or greater at conditions of _____ CFM entering air
temperature at the evaporator at _____ _F wet bulb and
_____ _F/_C dry bulb, and air entering the unit at _____
_F/_C.
The system will have a SEER of _____ Btuh/watt or
greater at DOE conditions.

Electrical Requirements
—

—

—
—

Nominal unit electrical characteristics will be _____ v,
single phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v to
_____ v.
Nominal unit electrical characteristics will be _____ v,
three phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v to
_____ v.
Unit electrical power will be single point connection.
Control circuit will be 24v.

Special Features
—

22

Refer to section of this literature identifying accessories
and descriptions for specific features and available
enhancements.

SYSTEM DESIGN SUMMARY

8.

9.
10.
11.

Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc.
Minimum outdoor operating air temperature without low--ambient operation accessory is 55_F (12.8_C).
Maximum outdoor operating air temperature for cooling mode is 125_F (51.7_C).
Minimum outdoor operating air temperature for heating mode is –30_F (–34.4_C).
Maximum outdoor operating air temperature for heating mode is 66_F (18.9_C).
For reliable operation, unit should be level in all horizontal planes.
For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or elevation differences between indoor and outdoor units
greater than 20 ft (6.1 m), consult Residential Piping and Longline Guideline and Service Manual available from equipment distributor.
If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing
lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4
mm).
Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
Do not apply capillary tube indoor coils to these units.
Factory--supplied filter drier must be installed.

25HCD3

1.
2.
3.
4.
5.
6.
7.

23

25HCD3
Copyright 2013 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231

Edition Date: 03/13

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

24

Catalog No: 25HCD3---1PD
Replaces: New

