48GS(N)-2SB 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS — PERFORMANCE DATA — CERTIFIED DIMENSION PRINT — CERTIFIED ROOF CURB DIMENSION PRINT Copyright 2000 Carrier Corporation Form 48GS-2SB Replaces 48GS-1SB Printed in U.S.A. 9-00 Catalog No. 514-896 Date: 48GS(N)018-060/48GX(N)024-060 Single-Package Gas Heating/ Electric Cooling Units Supersedes: JOB DATA: LOCATION: BUYER: BUYER P.O. # UNIT NUMBER: MODEL NUMBER: UIP M E NT STA NDARD 21 0 5 EQ RI 2 A AIR CO Y NING ITIO ND UNIT AR T IFIED O ARI A RT S C CE YING WITH PL OM MANUFACTUR ER PERFORMANCE DATA CERTIFIED BY: A2 3 48GS-2SB Rev.: CARRIER # DATE: DESCRIPTION 48GS(N)/48GX(N) units are self-contained, gas heating/electric cooling units designed for easy installation and maintenance and dependable performance. All units have discharge openings for either horizontal or downflow configuration, and all have low sound levels. Units are intended for outdoor installation and may be located on a rooftop, or a groundlevel concrete slab, or directly on the ground if local codes permit. FEATURES • Standard one year limited warranty for both 48GS and • Easy-to-service cabinets with single-panel accessibility. 48GX. • Direct-drive multi-speed, permanent split capacitor • 10 year warranty on the 48GX(N) compressor. (PSC) indoor motor is standard. • 5 year warranty on the 48GS(N) compressor. • Direct-drive, PSC outdoor fan motor. • 15 year warranty on the 48GX(N) gas-fired heat ex• Integrated gas control board provides safe and efficient changer. control of gas heating. • 10 year warranty on the 48GS(N) gas-fired heat exchanger. • Corrosion resistant gas heat exchangers. • Units certified and listed by UL and c-UL. Units are rated • Coils constructed of aluminum fins bonded to copper in accordance with ARI Standard 210. tubes. • Low sound ratings. • Wire grille provides additional protection. • Units are pre-wired, pre-piped, and pre-charged for min• “Envirotuff” composite rust-proof unit base pan. imum installation expense. • Sloped drain pan minimizes standing water in the unit. • 12 SEER cooling efficiency. • Refrigerant service connections make checking operat• Lightweight. ing pressures easier. • Compressor vibration isolation provides quieter operation. • Copper & pre-coated fin coils are available from the fac• Energy saving, direct spark ignition. tory by special order, for use in corrosive environments. • Easily converted for downflow operation with included • Low NOx units available for use in California. horizontal duct covers. •Three-phase units available. • Cabinets are constructed of heavy-duty, phosphated, zinc coated pre-painted steel capable of withstanding 500 hours in salt spray. PERFORMANCE DATA Unit Operating Weight________lb (unit); ________lb (curb) COOLING Net Total Capacity____________________________Btuh Net Sensible Capacity ________________________ Btuh Compressor Power Input__________kW @ ________ °F Outdoor-Air Temperature Indoor Entering-Air db__________°F –wb _________ °F Seasonal Energy Efficiency Ratio ___________________ CFM__________ Ext. Static Pressure___________in. wg Indoor Fan Motor______ Hp________ Rpm________Bhp 2 HEATING Input ______________________________________ Btuh Output ____________________________________ Btuh AFUE _______________________________________ % Power Input to Unit ___________________________ kW Integrated Capacity __________________________ Btuh Indoor Operating Temp _______________________°F db Outdoor-Air Temp ________________°F (Winter Design) COP/HSPF _________________Hi _______________ Lo ELECTRICAL DATA Unit Power Supply______Volts______Phase______ Hz Minimum Circuit Amps______Maximum Overcurrent Protection______ FIELD INSTALLED ACCESSORIES Economizer Crankcase Heater Manual air Damper Time Guard® II Device Filter Rack Compressor Hard Start Kit Flat Roof Curb LP conversion Kit 8 in .Height 0°F Low Ambient Kit (Motormaster® II) 14 in. Height Square-to-Round Duct Transition Kit Thermostat High Altitude Kit Programmable Controls Upgrade Kit Non-Programmable Lifting Kit NOTES: ___________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ 3 4 Cut along dotted line CERTIFIED DIMENSION PRINT C00090 5 CERTIFIED DIMENSION PRINT Cut along dotted line C00091 C00091 6 Return opening (11" X 16 1/2" clear) DRAWN BY : A.L.L. JOB NAME: EQUIPMENT: NOTES: SUBMITTED T O COMPANY: S U B M ITT A L 44 5/16" 17 /8" 3 Insulated deck pan Cut along dotted line 11" 28 3/4" 1" R/A duct *10 3/4" Wood Nailer Gasketing *Ductsiz e 14 " CPC RFCU RB00 7A00 A 8" CPC RFCU RB00 6A00 Supply opening (11" X 16 1/2" clear) A ODS Catalog Ordering No. SIDE VIEW 1" 44 5/16" 3" S/A duct *10 3/4" 1" C00077 Support HVAC unit base pan Gasketing Feature: • Constructed of heavy gage galvanized steel. • Roofcurb ships knocked down in corrugated box. • Quick-clip design for easy field assembly. • Insulated deck pan. • Gasketing package and hardware included. • Wood nailer provided. Roof Curb for Small Cabinet CERTIFIED DIMENSION PRINT 7 Side View • Constr ucted of heavy gage galyanized steel. • Quic k-clip design for easy field assembly. • Ships knocked down w/corrugated box. • Gask et package for complete outer perimeter flange and around duct openings. • W ood nailer provided. FEATURES: SUBMITTED T O: COMPANY: DRAWN BY: M. HARGIS JOB NAME: EQUIPMENT: NOTES: S U B M ITT A L Gasketing 40 5/16" 8" 14" CPRFCURB009A00 A 17 3/8" CPRFCURB008A00 ODS Catalog Ordering No. 16 3/16" 16 3/16" Roof Curb for Large Cabinet C00078 Deck pan (insulated) 44 7/16" A CERTIFIED ROOF CURB DIMENSION PRINT Cut along dotted line 8
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : 3.1-701 Create Date : 2000:10:06 11:08:16Z Modify Date : 2005:11:14 10:30:17-05:00 Metadata Date : 2005:11:14 10:30:17-05:00 Producer : Acrobat Distiller 2.0 for Windows Keywords : Format : application/pdf Title : Description : Creator : Carrier Corporation Subject : Document ID : uuid:d472b784-e1bc-4f47-af3e-c2adb64c53de Instance ID : uuid:2ae3e868-ba70-459f-bed9-d60a2823e50d Page Count : 8 Author : Carrier CorporationEXIF Metadata provided by EXIF.tools