48GS(N)-2SB

48GS(N)018-060
STANDARD EFFICIENCY
48GX(N)024-060
HIGH-EFFICIENCY
SINGLE-PACKAGE GAS HEATING
ELECTRIC COOLING UNITS
— PERFORMANCE DATA
— CERTIFIED DIMENSION PRINT
— CERTIFIED ROOF CURB
DIMENSION PRINT

Copyright 2000 Carrier Corporation
Form 48GS-2SB Replaces 48GS-1SB

Printed in U.S.A.

9-00

Catalog No. 514-896

Date:

48GS(N)018-060/48GX(N)024-060
Single-Package
Gas Heating/
Electric Cooling Units

Supersedes:

JOB DATA:

LOCATION:

BUYER:

BUYER P.O. #

UNIT NUMBER:

MODEL NUMBER:

UIP M E NT

STA

NDARD

21

0

5

EQ

RI

2

A

AIR
CO

Y

NING
ITIO
ND

UNIT
AR

T
IFIED O ARI A
RT
S
C
CE

YING WITH
PL
OM

MANUFACTUR
ER

PERFORMANCE DATA CERTIFIED BY:

A2

3

48GS-2SB

Rev.:

CARRIER #

DATE:

DESCRIPTION
48GS(N)/48GX(N) units are self-contained, gas heating/electric cooling
units designed for easy installation and maintenance and dependable performance. All units have discharge openings for either horizontal or
downflow configuration, and all have low sound levels. Units are intended for outdoor installation and may be located on a rooftop, or a groundlevel concrete slab, or directly on the ground if local codes permit.

FEATURES
• Standard one year limited warranty for both 48GS and
• Easy-to-service cabinets with single-panel accessibility.
48GX.
• Direct-drive multi-speed, permanent split capacitor
• 10 year warranty on the 48GX(N) compressor.
(PSC) indoor motor is standard.
• 5 year warranty on the 48GS(N) compressor.
• Direct-drive, PSC outdoor fan motor.
• 15 year warranty on the 48GX(N) gas-fired heat ex• Integrated gas control board provides safe and efficient
changer.
control of gas heating.
• 10 year warranty on the 48GS(N) gas-fired heat exchanger.
• Corrosion resistant gas heat exchangers.
• Units certified and listed by UL and c-UL. Units are rated
• Coils constructed of aluminum fins bonded to copper
in accordance with ARI Standard 210.
tubes.
• Low sound ratings.
• Wire grille provides additional protection.
• Units are pre-wired, pre-piped, and pre-charged for min• “Envirotuff” composite rust-proof unit base pan.
imum installation expense.
• Sloped drain pan minimizes standing water in the unit.
• 12 SEER cooling efficiency.
• Refrigerant service connections make checking operat• Lightweight.
ing pressures easier.
• Compressor vibration isolation provides quieter operation.
• Copper & pre-coated fin coils are available from the fac• Energy saving, direct spark ignition.
tory by special order, for use in corrosive environments.
• Easily converted for downflow operation with included
• Low NOx units available for use in California.
horizontal duct covers.
•Three-phase units available.
• Cabinets are constructed of heavy-duty, phosphated, zinc
coated pre-painted steel capable of withstanding 500
hours in salt spray.
PERFORMANCE DATA
Unit Operating Weight________lb (unit); ________lb
(curb)
COOLING
Net Total Capacity____________________________Btuh
Net Sensible Capacity ________________________ Btuh
Compressor Power Input__________kW @ ________ °F
Outdoor-Air Temperature
Indoor Entering-Air db__________°F –wb _________ °F
Seasonal Energy Efficiency Ratio ___________________
CFM__________ Ext. Static Pressure___________in. wg
Indoor Fan Motor______ Hp________ Rpm________Bhp

2

HEATING
Input ______________________________________ Btuh
Output ____________________________________ Btuh
AFUE _______________________________________ %
Power Input to Unit ___________________________ kW
Integrated Capacity __________________________ Btuh
Indoor Operating Temp _______________________°F db
Outdoor-Air Temp ________________°F (Winter Design)
COP/HSPF _________________Hi _______________ Lo

ELECTRICAL DATA
Unit Power Supply______Volts______Phase______ Hz
Minimum Circuit Amps______Maximum Overcurrent Protection______

FIELD INSTALLED ACCESSORIES
Economizer

Crankcase Heater

Manual air Damper

Time Guard® II Device

Filter Rack

Compressor Hard Start Kit

Flat Roof Curb

LP conversion Kit

8 in .Height

0°F Low Ambient Kit (Motormaster® II)

14 in. Height

Square-to-Round Duct Transition Kit

Thermostat

High Altitude Kit

Programmable

Controls Upgrade Kit

Non-Programmable

Lifting Kit

NOTES: ___________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________

3

4
Cut along dotted line

CERTIFIED DIMENSION PRINT

C00090

5

CERTIFIED DIMENSION PRINT

Cut along dotted line

C00091

C00091

6

Return opening
(11" X 16 1/2" clear)

DRAWN BY : A.L.L.
JOB NAME:
EQUIPMENT:
NOTES:

SUBMITTED T O
COMPANY:

S U B M ITT A L

44 5/16"

17 /8"

3

Insulated
deck pan

Cut along dotted line

11"

28 3/4"

1"

R/A duct

*10 3/4"

Wood Nailer

Gasketing

*Ductsiz e

14 "

CPC RFCU RB00 7A00

A

8"

CPC RFCU RB00 6A00

Supply opening
(11" X 16 1/2" clear)

A

ODS Catalog Ordering No.

SIDE VIEW

1"

44 5/16"

3"

S/A duct

*10 3/4"

1"

C00077

Support

HVAC unit
base pan
Gasketing

Feature:
• Constructed of heavy gage galvanized steel.
• Roofcurb ships knocked down in corrugated
box.
• Quick-clip design for easy field assembly.
• Insulated deck pan.
• Gasketing package and hardware included.
• Wood nailer provided.

Roof Curb for Small Cabinet

CERTIFIED DIMENSION PRINT

7

Side View

• Constr ucted of heavy gage galyanized steel.
• Quic k-clip design for easy field assembly.
• Ships knocked down w/corrugated box.
• Gask et package for complete outer perimeter
flange and around duct openings.
• W ood nailer provided.

FEATURES:

SUBMITTED T O:
COMPANY:
DRAWN BY: M. HARGIS
JOB NAME:
EQUIPMENT:
NOTES:

S U B M ITT A L

Gasketing
40 5/16"

8"
14"

CPRFCURB009A00

A

17 3/8"

CPRFCURB008A00

ODS Catalog Ordering No.

16 3/16"

16 3/16"

Roof Curb for Large Cabinet

C00078

Deck pan (insulated)

44 7/16"

A

CERTIFIED ROOF CURB DIMENSION PRINT

Cut along dotted line

8



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Create Date                     : 2000:10:06 11:08:16Z
Modify Date                     : 2005:11:14 10:30:17-05:00
Metadata Date                   : 2005:11:14 10:30:17-05:00
Producer                        : Acrobat Distiller 2.0 for Windows
Keywords                        : 
Format                          : application/pdf
Title                           : 
Description                     : 
Creator                         : Carrier Corporation
Subject                         : 
Document ID                     : uuid:d472b784-e1bc-4f47-af3e-c2adb64c53de
Instance ID                     : uuid:2ae3e868-ba70-459f-bed9-d60a2823e50d
Page Count                      : 8
Author                          : Carrier Corporation
EXIF Metadata provided by EXIF.tools

Navigation menu