Carrier 50Xp Users Manual 05PD
50XP to the manual 6e085886-5a07-4bb8-b8d5-8466a80c0ddb
2015-01-24
: Carrier Carrier-50Xp-Users-Manual-310489 carrier-50xp-users-manual-310489 carrier pdf
Open the PDF directly: View PDF .
Page Count: 24
Download | |
Open PDF In Browser | View PDF |
50XP Performancet 13 SEER Single ---Packaged Air Conditioner System with PuronR (R ---410A) Refrigerant Single and Three Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data C99064 Fig. 1 -- Unit 50XP Single--Packaged Products with Energy--Saving Features and PuronR refrigerant. S Up to 13.5 SEER S Factory--Installed TXV S Variable Speed Blower--Standard S Low Sound Levels FEATURES/BENEFITS One--piece cooling unit with optional electric heater, low installation cost, dependable performance and easy maintenance. Efficient operation High--efficiency design with a SEER (Seasonal Energy Efficiency Ratio) of up to 13.5. Puron Environmentally Sound Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems proving highly reliable, environmentally sound performance. IdealHumidity Technology featuring Thermidistat control and Variable Speed Blower motor that provides greater comfort, humidity control, and energy efficiency. You can expect up to 30 times better dehumidification; economical constant fan for less than $50 a year, which provides improved indoor air quality and more even temperatures from room to room; and reduced indoor noise due to lower air velocity. In addition, you’ll realize improved installation flexibility with 3 different airflow choices for best overall comfort. Easy Installation Factory--assembled package is a fully self--contained, electric cooling unit that is prewired, pre--piped, and pre--charged for minimum installation expense. These units are available in a variety of standard cooling sizes with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Durable, dependable components Scroll Compressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection. Convertible duct configuration Unit is designed for easy use in either downflow or horizontal applications. Each unit is easily converted from horizontal to downflow. Downflow operation is easily provided in the field to allow vertical ductwork connections. The basepan utilizes knockout style seals on the bottom openings to ensure a positive seal in the horizontal airflow mode. Direct--drive variable speed blower motor is standard on all models. Direct--drive PSC condenser--fan motors are designed to help reduce energy consumption and provide for cooing operation down to 55_F (13_C) outdoor temperature. Motormasterr II low ambient kit is available as a field--installed accessory. Thermostat controls Time Guardr II anti--short cycle protection circuitry. If a non--corporate thermostat without anti--short cycle protection is used the Time Guard II field--installed anti--short cycle kit is recommended. Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. Thermostatic Expansion Valve -- A hard shutoff, balance port TXV maintains a constant superheat at the evaporator exit (cooling cycle) resulting in higher overall system efficiency. Evaporator and condenser coils are computer--designed for optimum heat transfer and cooling efficiency. The evaporator coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection again damage. The condenser coil is internally mounted on the top tier of the unit. Copper fin coils and pre--coated fin coils are available from the factory by special order. these coils are recommended in applications where aluminum fins are likely to be damaged due to corrosion. They are ideal for seacoast applications. High and Low Pressure Switches provide added reliability for the compressor. 1 50XP Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 72dBA. (See Page 4.) Easy to service cabinets provide easy single--panel accessibility to serviceable components during maintenance and installation. The basepan with integrated drain pan provides easy ground level installation with or without a mounting pad. Convenient handholds are provided to manipulate the unit on the jobsite. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4--in. (19.05 mm) wide perimeter flange makes frame mounting on a rooftop easy. Louvered Grille provides hail and vandalism protection for the coil. Cabinets are constructed of heavyduty, phosphated, zinc--coated prepainted steel capable of withstanding 500 hours of salt spray. Interior surfaces of the evaporator and electric heater compartments are insulated with cleanable semi--rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers No. 62P.) The sloped drain pan minimizes standing water in the drain. An external drain is provided. TABLE OF CONTENTS FEATURES/BENEFITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1--2 MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . 3 ARI CAPACITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 OPTIONS AND ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . 6 BASE UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . 8--9 ACCESSORY ROOF CURB . . . . . . . . . . . . . . . . . . . . . . . . . . 10 SELECTION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . 11 PERFORMANCE DATA . . . . . . . . . . . . . . . . . . . . . . . . . . 12--16 TYPICAL PIPING AND WIRING . . . . . . . . . . . . . . . . . . . . . 17 APPLICATION DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 ELECTRICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19--20 TYPICAL WIRING SCHEMATICS . . . . . . . . . . . . . . . . . 21--23 CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . 25--26 2 MODEL NUMBER NOMENCLATURE 50XP --- 024 --- --- --- 3 0 1 --- --- Options BT --- AL evap, vinyl condenser CC --- AL evap, CU condenser CU --- CU evap & condenser TP --- Base unit with tin plated indoor coil hairpins TV --- TP with vinyl coating on outdoor coil TC --- TP with AL indoor coil & CU/CU outdoor coil Type of Unit 50XP --- Single Packaged Air Conditioner System N/A Nominal Cooling Capacity 024 --- 2.0 Tons 030 --- 2.5 Tons 036 --- 3.0 Tons 042 --- 3.5 Tons 048 --- 4.0 Tons 060 --- 5.0 Tons Packaging Series Electrical Supply 3 --- 208/230 ---1 ---60 5 --- 208/230 ---3 ---60 N/A LEGEND AL --- Aluminum CU --- Copper ISO 9001:2000 REGISTERED 3 50XP See Price Page for full list of factory options. Only used if ordering an option ARI* CAPACITIES 50XP Cooling Capacities and Efficiencies UNIT 50XP NOMINAL TONS STANDARD CFM 024 030 036 042 048 060 2 2--1/2 3 3--1/2 4 5 770 960 1100 1450 1450 1710 LEGEND dB--- Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of Performance * Air Conditioning & Refrigeration Institute. **At “A” conditions---80_F (26.7_C) indoor db/67_F (19.4_C) indoor wb & 95_F (35_C) outdoor db. { Rated in accordance with U.S. Government DOE Department of Energy) test procedures and/or ARI Standards 210/240. NET COOLING CAPACITIES (Btuh) 24,000 29,000 36,000 41,000 45,000 57,000 EER** SEER† 11.0 11.0 11.2 11.2 11.0 11.0 13.2 13.0 13.5 13.0 13.0 13.0 Notes: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80°F (26.7_C) db, 67°F wb (19.4_C) indoor entering---air temperature and 95°F db (35_C) outdoor entering---air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. A--Weighted Sound Power (dBA) 50XP 024 030 036 042 048 060 * STANDARD RATING (dBA) 72 72 72 72 78 78 TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment) 125 250 500 1000 2000 4000 8000 58.8 58.8 60.7 56.7 62.4 63.5 63.5 63.5 63.3 62.8 69.9 67.6 67.2 67.2 66.8 67.8 71.3 71.8 66.9 66.9 66.5 67.4 73.4 75.5 63.7 63.7 64.2 63.7 70.0 71.0 58.3 58.3 60.3 57.7 66.3 68.1 50.0 50.0 53.0 50.8 60.1 59.9 Tested in accordance with ARI Standard 270 (not listed in ARI). 4 PHYSICAL DATA Physical Data--Unit 50XP COMPRESSORS Quantity REFRIGERANT (R --- 410A) Quantity (lb.) Quantity (kg) REFRIGERANT METERING DEVICE OUTDOOR COIL Rows...Fins/in. Face Area (sq ft) OUTDOOR FAN Nominal Cfm Diameter (in.) Diameter (mm) Motor Hp (Rpm) INDOOR COIL Rows...Fins/in. Face Area (sq ft) INDOOR BLOWER Nominal Cooling Airflow (Cfm) Size (in.) Size (mm.) Motor HP (RPM) HIGH --- PRESSURE SWITCH (psig) Cut--- out Reset (Auto) LOSS--- OF--- CHARGE / LOW --- PRESSURE SWITCH (Liquid Line) (psig) cut--- out Reset (auto) RETURN--- AIR FILTERS†} Throwaway Size (in.) Throwaway Size (mm) 024 2 356 161 030 2 ---1/2 360 163 036 3 378 171 042 3 ---1/2 436 198 048 4 470 213 060 5 515 234 10.7 4.9 11.25 5.1 13.2 6.0 Scroll 1 7.3 3.3 8.0 3.6 9.5 4.3 TXV 2...21 11.95 2...21 12.0 2...21 13.6 2...21 15.4 2...21 17.4 2...21 19.3 2350 22 558.8 1/8 (825) 2700 22 558.8 1/8 (825) 2350 22 558.8 1/8 (825) 2800 22 558.8 1/8 (825) 3300 22 558.8 1/4 (1100) 3300 22 558.8 1/4 (1100) 3...15 3.7 3...15 3.7 4...15 3.7 3...15 4.7 4...15 4.7 4...17 5.7 800 10x10 254x254 1/2 (1050) 1000 10x10 254x254 1/2 (1050) 1400 11x10 279.4x254 3/4 (1075) 1750 11x10 279.4x254 1.0 (1040) 1100 1400 11x10 11x10 279.4x254 279.4x254 3/4 (1000) 3/4 (1075) 650 +/ --- 15 420 +/ --- 25 20 +/ --- 5 45 +/ --- 10 20x20x1 508x508x25 20x24x1 508x610x25 24x30x1 610x762x25 Required filter sizes shown are based on the larger of the ARI (Air Conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450 ft/minute for high ---capacity type. Air filter pressure drop for non ---standard filters must not exceed 0.08 IN. W.C.. } If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity. { 5 50XP UNIT SIZE NOMINAL CAPACITY (ton) SHIPPING WEIGHT (lb) SHIPPING WEIGHT (kg) OPTIONS AND ACCESSORIES compartment. Heater sizes range from 5.0 to 20.0 kW. The electric heater design allows the use of a single--point power supply for the entire unit, resulting in lower installed costs. Filter Rack features easy installation, serviceability, and high--filtering performance for vertical or horizontal applications. Flat roof curbs in both 8 in. (203.2 mm) and 14 in. (355.6 mm) sizes are available for roof mounted applications. Factory--installed options 50XP Coil options include Tin--Plated* indoor hairpins, copper/copper and vinyl--coated construction for refrigerant coils. Units are shipped standard with copper tube/aluminum fin construction. See model number nomenclature for coil options. *Tin--Plated indoor coils are built with special hairpins that are designed to resist both general pitting corrosion and excessive indoor corrosion(Formicary Corrosion). Field--installed accessories Square--to--round duct transition kit enables 024--048 size units to be fitted to 14 in. (355.6 mm) round ductwork. Thermidistat Control coupled with the system’s variable speed indoor blower delivers Carrier’s patented IdealHumidity Technology that allows for even greater humidity control. Along with more precisely controlling temperature and humidity, the Thermidistat offers full seven--day programmability allowing you to further customize your comfort and energy savings. Thermostats provide control for the system heating and cooling functions. Thermostat models are available in both programmable and non--programmable versions. Crankcase Heater provides anti--floodback protection for low--load cooling applications. Compressor start kit assists compressor start--up by providing additional starting torque on single phase units and prolongs compressor motor life. Rigging kit includes lifting brackets which are inserted into the unit base rigging holds to lift unit for rooftop applications. Low--ambient kit (Motormaster II control) allows the use of mechanical cooling down to outdoor temperatures as low as 0_F (--17_C) when properly installed. Solid--state Time Guard II device provides short--cycling protection for the compressor. Not required with corporate electronic thermostats. Lifting kit, including 4 metal brackets that are available to assist in lifting this product onto a roof application. Economizer with Solid-- State Controls and Barometric Relief Dampers Manual Air Damper (25% open) Electric Heaters Filter Rack Flat Roof Curbs (8-- in. and 14-- in.) (203.2 and 355.6 mm) Square-- to-- Round Duct Transition Kit Thermidistatt Thermostats Crankcase Heater Compressor Start Kit (for use on single--phase units only) Rigging Kit Low Ambient Kit (Motormaster® II Control) Solid-- State Time Guard® II Device Lifting Kit Economizer with solid--state controls and barometric relief dampers includes filter racks and provide outdoor air during cooling and reduce compressor operation. Manual outside air damper includes hood and filter rack with adjustable damper blade for up to 25% outdoor air. Electric heaters provide additional heat in the unit when required. Each package has a heater module that slides into the controls Electric Heaters CATALOG ORDERING NO. NOMINAL CAPACITY (kW) USED WITH SIZES FUSES 024 030 036 042 048 060 ELECTRIC HEATERS (208/230 — SINGLE PHASE — 60 Hz) CPHEATER052A00 5.0 0 X X X X X X CPHEATER069A00 7.5 0 X X X X X X CPHEATER065A00 10.0 0 X X X X X X CPHEATER051A00 15.0 4 X X X X X CPHEATER053A00 20.0 6 X X 20.0 6 CPHEATER054A00 X ELECTRIC HEATERS (208/230 — THREE PHASE — 60 Hz) CPHEATER055A00 5.0 0 X X X X CPHEATER056A00 10.0 0 X X X X X CPHEATER057A00 15.0 0 X X X X CPHEATER059A00 20.0 6 X X X X NOTE: Electric heaters are rated at 240v. Refer to Multiplication Factors table for other voltages. X = Approved combinations. Minimum Airflow for Reliable Electric Heater Operation (CFM) UNIT SIZE AIRFLOW 024 750 030 1000 036 1250 042 1400 6 048 1500 060 1800 ECONOMIZER COIL FILTER ACCESS DOOR (HORIZONTAL APPLICATION ONLY.) DO NOT REMOVE FROM DOWNFLOW DISCHARGE. FILTER REPLACEMENT PANEL ECONOMIZER HOLE FOR ECONOMIZER WIRING HARDNESS 17 13/32 11 13/32” CAULK BOTTOM CORNER OF ECONOMIZER ON EACH SIDE SIDE VIEW 16 1/4” HINGED FILTER ACCESS DOOR FI LTER COIL 50XP RAINHOOD DOOR LATCH ANGLE INSTALL FILTER ACCESS DOOR STICKER ALUMINUM FILTER ECONOMIZER BASE FLANGE ON BASE DETAIL MANUAL OUTSIDE AIR DAMPER FILTER RACK BEND FLANGE AT 90˚ -SCREW TO DIVIDER WITH 1-IN. SCREW REPLACEMENT PANEL MANUAL OUTSIDE AIR HOOD TOP FILTER RACK EV APORATOR COIL DAMPER BLADE BOTTOM FILTER RACK A05239 7 50XP UNIT DIMENSIONS - 50XP024--036 A08452 8 50XP UNIT DIMENSIONS - 50XP042--060 A08453 9 ACCESSORY ROOF CURB -- 50XP024--060 HVAC unit base HVAC unit base Screw (NO TE A) Screw (NOTE A) Gasketing inner flange* *Gasketing outer flange Gask eting inner flange* *Gasketing outer flange Wood nailer* Wood nailer* Flashing field supplied Flashing field supplied Roofcurb* Insulation (field supplied) Roofing material field supplied 50XP Insulation (field supplied) Roofing material field supplied Duct work field supplied Cant strip field supplied Roofcurb* Cant strip field supplied Duct work field supplied Roof Roof *Provided with roofcurb *Provided with roofcurb Roof Curb for Small Cabinet Roof Curb for Large Cabinet Note A: When unit mounting scre w is used , retainer bracket must also be used. Note A: When unit mounting scre w is used , retainer bracket must also be used. Supply opening (B x C) B Typ. 44 5/ 16" D CTyp. (1126 mm) R/A A Gasket around duct Insulated deck pan Short Support Insulated deck pan S/A Gasket around outer edge Long Support Return opening (B X C) C00076 UNIT SIZE 50XP024-- 036 50XP042-- 060 ORDERING NUMBER CPRFCURB006A00 CPRFCURB007A00 CPRFCURB008A00 CPRFCURB009A00 A IN. (MM) 8 (203) 14 (356) 8 (203) 14 (356) B IN. (MM) 11 (279) 11 (279) 16--3/16 (411) 16--3/16 (411) C IN. (MM) 16--1/2 (419) 16--1/2 (419) 17--3/8 (441) 17--3/8 (441) D IN. (MM) 28--3/4 (730) 28--3/4 (730) 40--1/4 (1022) 40--1/4 (1022) NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied, as required, to unit being installed. 3. Roof curb is made of 16--gauge steel. 4. Attach ductwork to curb (flanges of duct rest on curb). 5. Insulated panels: 1--in. (25.4 mm) thick fiberglass 1 lb. density. 6. When unit mounting screw is used (see Note A), a retainer bracket must be used as well. This bracket must also be used when required by code for hurricane or seismic conditions. This bracket is available through Micrometl. 10 50XP UNIT SUGGESTED RIGGING 1 2 (914 mm) DETAIL A 4 A07216 Unit* Rigging Weight SMALL CABINET 030 030 024 024 lb kg lb 345 156 349 036 036 kg lb kg 158 367 166 A08005 Unit* Rigging Weight LARGE CABINET 048 048 042 042 lb kg lb kg 060 lb 060 kg 425 193 459 208 504 229 NOTE: See dimensional drawing for corner weight distribution. Corner weights shown on drawing are based on unit---only weights and do not include packaging. SELECTION PROCEDURE (WITH EXAMPLE) 1. Determine cooling and heating requirements at design conditions: 4. Determine fan speed and power requirements at design conditions. Given: Required Cooling Capacity (TC) . . . . . . . . . . 34,500 Btuh Sensible Heat Capacity (SHC) . . . . . . . . . . . . 26,000 Btuh Required Heating Capacity . . . . . . . . . . . . . . . 15,000 Btuh Condenser Entering Air Temperature . . . . . . . . 95°F(35°C) Indoor--Air Temperature . . . . . . . . . . . . . 80°F (26°C) edb 67°F (19°C) ewb Evaporator Air Quantity . . . . . . . . . . . . . . . . . . 1200 CFM External Static Pressure . . . . . . . . . . . . . . . . . 0.20 IN. W.C. Electrical Characteristics . . . . . . . . . . . . . . . . . . . 230--1--60 Before entering the air delivery tables, calculate the total static pressure required. From the given example, the Filter Pressure Drop Table, and the Accessory Electric Heat Pressure Drop table, find: External Static Pressure 0.200 IN. W.C. Filter 0.130 IN. W.C. Wet Coil Pressure Drop 0.032 IN. W.C. Total Static Pressure 0.362 IN. W.C. Enter the table for Dry Coil Air Delivery—At 0.362 IN. W.C. ESP (external static pressure) and NOM speed pin selection, the motor will deliver 1235 cfm. 2. Select unit based on required cooling capacity. Enter Net Cooling Capacities table at condenser entering temperature of 95°F (35°C). The 036 unit at 1225 CFM and 67°F (19°C) ewb (entering wet bulb) will provide a total capacity of 36,500 Btuh and a SHC of 27,600 Btuh. Calculate SHC correction, if required, using Note 4 under Cooling Capacities tables. 5. Select unit that corresponds to power source available. The Electrical Data Table shows that the unit is designed to operate at 208--1--60. 3. Select electric heat. The required heating capacity is 15,000 Btuh. Determine additional electric heat capacity in kW. 15,000 Btuh = 4.4kW of heat required 3,414 Btuh/kW Enter the Electric Heater Packages table for 208/240, single--phase, 036 unit. The 5 kW heater at 240v most closely satisfies the heating required. To calculate kW at the 208v, multiply the heater kW by multiplication factor 0.75 found in the Wattage Multiplication Factors table. 5 kW x 0.75 = 3.75 kW 3.75 kW x 3414 = 12,802.50 Btuh 11 50XP 3 12 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 62 (16.7) 24.0 21.9 1.7 22.9 21.4 1.9 21.8 20.8 2.2 20.5 20.2 2.4 19.2 19.4 2.7 17.8 18.5 2.9 62 (16.7) TC 27.9 75 SHC 24.1 (23.9) kW 2.1 TC 26.9 85 SHC 23.8 (29.4) kW 2.3 TC 25.6 95 SHC 23.1 (35) kW 2.6 TC 24.3 105 SHC 22.4 (40.6) kW 2.9 TC 22.8 115 SHC 21.7 (46.1) kW 3.2 TC 21.4 125 SHC 20.7 (51.7) kW 3.5 See Legend and Notes on Page 15. Temp _F (_C) Outdoor Air Entering Condenser 50XP030 125 (51.7) 115 (46.1) 105 (104.6) 95 (35) 85 (29.4) 75 (23.9) Temp _F (_C) Outdoor Air Entering Condenser 50XP024 PERFORMANCE DATA 67 (19.4) 26.5 18.7 1.8 25.3 18.1 2.0 24.0 17.6 2.2 22.6 16.9 2.4 21.1 16.3 2.7 19.4 15.5 3.0 67 (19.4) 30.7 20.6 2.1 29.5 20.3 2.4 28.2 19.9 2.6 26.6 19.3 2.9 24.9 18.8 3.2 24.9 18.8 3.2 875/0.06 63* (17.2) 28.6 20 2.1 27.5 19.5 2.3 26.2 19.1 2.6 24.7 18.6 2.9 23.2 18 3.2 21.4 17.3 3.5 63* (17.2) 24.5 21.3 1.7 23.3 20.7 1.9 22.2 20.2 2.2 20.9 19.5 2.4 19.5 18.8 2.7 18.0 18.1 2.9 800/0.026 72 (22.2) 33.6 16.8 2.1 32.3 16.4 2.4 30.8 16 2.6 29.2 15.4 2.9 27.3 14.8 3.2 27.3 14.8 3.2 72 (22.2) 29.1 15.4 1.8 27.9 14.9 2.0 26.5 14.3 2.2 25.0 13.7 2.4 23.3 13.0 2.7 21.4 12.3 3.0 Evaporator Air --- CFM/BF 1000/0.07 Evaporator Air --- Ewb _F (_C) 62 63* 67 72 (16.7) (17.2) (19.4) (22.2) 28.8 29.4 31.6 34.5 26 21.2 22.1 17.8 2.1 2.1 2.1 2.2 27.6 28.1 30.2 33.1 25.6 20.8 21.7 17.4 2.3 2.4 2.4 2.4 26.3 26.8 28.8 31.5 24.7 20.5 21.3 16.9 2.6 2.6 2.6 2.6 25.1 25.3 27.2 29.7 23.8 19.9 20.8 16.3 2.9 2.9 2.9 2.9 23.8 23.6 25.3 27.7 22.3 19.3 20.2 15.7 3.2 3.2 3.2 3.2 23.8 23.6 25.3 27.7 22.3 19.3 20.2 15.7 3.2 3.2 3.2 3.2 62 (16.7) 24.6 23.5 1.8 23.5 22.9 2.0 22.3 22.3 2.2 21.0 21.6 2.4 19.8 20.6 2.7 18.5 19.2 3.0 Evaporator Air --- CFM/BF 900/0.032 Evaporator Air --- Ewb _F (_C) 63* 67 72 (17.2) (19.4) (22.2) 25.1 27.1 29.8 22.8 19.8 16.1 1.8 1.8 1.8 23.9 25.8 28.5 22.2 19.2 15.6 2.0 2.0 2.0 22.6 24.5 27.0 21.6 18.7 15.0 2.2 2.2 2.2 21.3 23.0 25.4 20.9 18.0 14.3 2.4 2.5 2.5 19.9 21.5 23.7 20.2 17.3 13.7 2.7 2.7 2.7 18.5 19.5 21.7 19.2 16.5 12.9 3.0 3.0 3.0 62 (19.7) 29.3 27 2.1 28.3 26.5 2.4 27 26.2 2.6 25.9 24.4 2.9 24.5 23.7 3.2 24.5 23.7 3.2 62 (19.7) 25.1 25.0 1.8 23.9 24.3 2.0 22.7 23.6 2.2 21.6 22.5 2.5 20.7 21.5 2.7 19.0 19.8 3.0 50XP 67 (19.4) 27.4 20.8 1.8 26.2 20.3 2.1 24.8 19.7 2.3 23.3 19.0 2.5 21.7 18.3 2.8 19.9 17.6 3.1 63* (17.2) 30 22.6 2.1 28.7 22.1 2.4 27.3 21.7 2.6 25.7 21.1 2.9 24 20.5 3.2 24 20.5 3.2 67 (19.4) 32.2 23.5 2.1 30.8 23.1 2.4 29.3 22.6 2.6 27.5 22.1 2.9 25.7 21.5 3.2 25.7 21.5 3.2 1125/0.08 63* (17.2) 25.5 24.2 1.8 24.3 23.6 2.0 23.0 22.9 2.2 21.7 22.2 2.5 20.4 21.2 2.7 19.0 19.7 3.0 1000/0.04 72 (22.2) 35.2 18.7 2.2 33.7 18.3 2.4 32 17.8 2.6 30.1 17.2 2.9 28.1 16.6 3.2 28.1 16.6 3.2 72 (22.2) 30.4 16.7 1.9 28.9 16.2 2.1 27.4 15.6 2.3 25.7 14.9 2.5 23.6 14.1 2.8 21.9 13.5 3.1 13 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 62 (16.7) 36.2 33.2 2.7 34.6 32.4 2.9 33.0 31.6 3.2 31.3 30.6 3.6 29.6 29.3 4.0 27.8 27.5 4.4 62 (16.7) TC 39.6 75 SHC 33.5 (23.9) kW 3.0 TC 37.9 85 SHC 32.8 (29.4) kW 3.3 TC 36.2 95 SHC 32.0 (35) kW 3.7 TC 34.2 105 SHC 31.0 (104.6) kW 4.1 TC 32.1 115 SHC 30.0 (46.1) kW 4.5 TC 29.8 125 SHC 28.6 (51.7) kW 4.9 See Legend and Notes on Page 15. Temp _F (_C) Outdoor Air Entering Condenser 50XP042 125 (51.7) 115 (46.1) 105 (104.6) 95 (35) 85 (29.4) 75 (23.9) Temp _F (_C) Outdoor Air Entering Condenser 50XP036 67 (19.4) 39.7 27.8 2.7 37.9 27.1 3.0 36.0 26.4 3.3 34.0 25.6 3.6 31.8 24.8 4.0 29.4 23.9 4.4 63* (17.2) 40.4 27.6 3.0 38.7 26.9 3.3 36.8 26.1 3.7 34.8 25.2 4.1 32.6 24.3 4.5 30.1 23.2 4.9 67 (19.4) 43.4 28.6 3.0 41.5 27.8 3.4 39.6 27.0 3.7 37.4 26.2 4.1 35.0 25.2 4.5 32.3 24.2 4.9 1225/0.06 63* (17.2) 36.8 26.7 2.7 35.1 26.0 2.9 33.4 25.3 3.2 31.5 24.5 3.6 29.4 23.7 4.0 27.2 22.8 4.3 1100/0.06 PERFORMANCE DATA (CONT) 72 (22.2) 47.6 23.4 3.1 45.5 22.7 3.4 43.4 21.9 3.8 41.0 21.1 4.1 38.4 20.2 4.5 35.3 19.1 5.0 72 (22.2) 43.8 22.3 2.7 41.8 21.6 3.0 39.7 20.9 3.3 37.5 20.1 3.6 35.0 19.3 4.0 32.4 18.4 4.4 Evaporator Air --- CFM/BF 1400/0.07 Evaporator Air --- Ewb _F (_C) 62 63* 67 72 (16.7) (17.2) (19.4) (22.2) 40.5 41.2 44.2 48.4 35.4 29.0 30.0 24.3 3.0 3.0 3.0 3.1 38.7 39.4 42.3 46.3 34.6 28.2 29.2 23.6 3.3 3.3 3.4 3.4 36.9 37.5 40.3 44.1 33.8 27.4 28.4 22.8 3.7 3.7 3.7 3.8 34.9 35.4 38.0 41.6 32.7 26.5 27.6 22.0 4.1 4.1 4.1 4.1 32.8 33.1 35.5 38.9 31.4 25.6 26.6 21.0 4.5 4.5 4.5 4.6 30.6 30.5 32.7 35.7 29.6 24.5 25.5 20.0 4.9 4.9 4.9 5.0 Evaporator Air --- CFM/BF 1225/0.07 Evaporator Air --- Ewb _F (_C) 62 63* 67 72 (16.7) (17.2) (19.4) (22.2) 36.9 37.4 40.3 44.4 34.7 27.9 29.0 23.1 2.7 2.7 2.7 2.8 35.3 35.6 38.4 42.4 34.0 27.1 28.3 22.4 3.0 3.0 3.0 3.0 33.7 33.8 36.5 40.2 32.9 26.4 27.6 21.7 3.3 3.3 3.3 3.4 32.1 31.9 34.3 37.9 31.5 25.7 26.8 20.9 3.6 3.6 3.7 3.7 30.4 29.8 32.1 35.4 30.0 24.8 26.0 20.0 4.0 4.0 4.0 4.0 28.4 27.5 29.7 32.7 28.2 23.8 25.0 19.1 4.4 4.4 4.4 4.4 50XP 62 (19.7) 41.5 37.9 3.0 39.7 37.0 3.3 37.8 35.9 3.7 36.0 34.3 4.1 34.0 32.8 4.5 31.7 30.6 4.9 62 (19.7) 37.9 36.9 2.8 36.4 35.6 3.1 34.8 34.4 3.4 33.1 32.8 3.8 31.3 31.0 4.1 29.3 29.0 4.5 67 (19.4) 41.0 30.9 2.8 39.1 30.2 3.1 37.0 29.4 3.4 34.9 28.6 3.8 32.6 27.7 4.1 30.1 26.7 4.5 63* (17.2) 42.1 30.8 3.0 40.2 30.0 3.3 38.2 29.1 3.7 36.0 28.3 4.1 33.7 27.3 4.5 31.0 26.1 4.9 67 (19.4) 45.1 31.9 3.0 43.2 31.1 3.4 41.0 30.3 3.7 38.7 29.4 4.1 36.1 28.5 4.5 33.2 27.3 4.9 1575/0.08 63* (17.2) 38.1 29.6 2.8 36.3 28.9 3.1 34.4 28.1 3.4 32.4 27.3 3.7 30.3 26.4 4.1 28.0 25.4 4.5 1400/0.08 72 (22.2) 49.4 25.6 3.1 47.2 24.8 3.4 44.9 24.0 3.8 42.3 23.2 4.1 39.5 22.2 4.6 36.2 21.1 5.0 72 (22.2) 45.1 24.2 2.9 43.1 23.6 3.2 40.8 22.8 3.5 38.4 22.0 3.8 35.8 21.1 4.2 33.0 20.2 4.5 14 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 62 (16.7) 45.0 39.3 3.4 42.8 38.2 3.7 40.6 36.9 4.1 38.2 35.7 4.6 35.7 34.4 5.0 33.4 32.1 5.6 62 (16.7) TC 57.2 75 SHC 49.4 (23.9) kW 4.1 TC 54.7 85 SHC 48.2 (29.4) kW 4.5 TC 52.2 95 SHC 47.0 (35) kW 5.0 TC 49.4 105 SHC 45.7 (104.6) kW 5.5 TC 46.5 115 SHC 44.3 (46.1) kW 6.1 TC 43.3 125 SHC 42.8 (51.7) kW 6.7 See Legend and Notes on Page 15. Temp _F (_C) Outdoor Air Entering Condenser 50XP060 125 (51.7) 115 (46.1) 105 (104.6) 95 (35) 85 (29.4) 75 (23.9) Temp _F (_C) Outdoor Air Entering Condenser 50XP048 67 (19.4) 49.6 33.4 3.4 47.2 32.3 3.8 44.7 31.2 4.2 42.1 30.1 4.6 39.3 28.9 5.1 36.2 27.6 5.6 63* (17.2) 58.2 47.9 4.1 55.6 46.7 4.5 53.0 45.4 5.0 50.2 44.1 5.6 47.2 42.7 6.2 43.9 41.2 6.8 67 (19.4) 62.4 41.6 4.2 59.7 40.4 4.6 56.9 39.2 5.1 53.8 37.9 5.6 50.5 36.4 6.2 46.7 34.9 6.8 1500/0.04 63* (17.2) 45.8 32.0 3.4 43.6 30.9 3.7 41.3 29.8 4.1 38.9 28.7 4.6 36.3 27.5 5.0 33.4 26.2 5.6 1260/0.06 PERFORMANCE DATA (CONT) 72 (22.2) 68.1 33.8 4.2 65.2 32.6 4.7 62.0 31.4 5.2 58.7 30.1 5.7 55.0 28.7 6.3 52.2 27.8 6.8 72 (22.2) 54.7 27.2 3.4 52.1 26.2 3.8 49.4 25.2 4.2 46.4 24.0 4.6 43.3 22.9 5.1 39.4 21.5 5.7 Evaporator Air --- CFM/BF 1750/0.07 Evaporator Air --- Ewb _F (_C) 62 63* 67 72 (16.7) (17.2) (19.4) (22.2) 58.8 59.7 64.0 69.8 53.6 51.8 44.5 35.4 4.2 4.3 4.3 4.4 56.2 57.0 61.1 66.6 52.4 50.5 43.2 34.2 4.7 4.7 4.8 4.9 53.5 54.3 58.0 63.2 51.1 49.2 41.9 32.9 5.1 5.2 5.3 5.3 50.7 51.4 54.8 59.6 49.8 47.9 40.6 31.6 5.7 5.7 5.8 5.9 48.1 48.3 51.3 56.8 48.1 46.6 39.2 30.6 6.2 6.3 6.4 6.4 45.2 45.1 47.4 52.5 45.2 45.1 37.6 28.9 6.8 6.9 7.0 7.0 Evaporator Air --- CFM/BF 1400/0.06 Evaporator Air --- Ewb _F (_C) 62 63* 67 72 (16.7) (17.2) (19.4) (22.2) 46.7 47.3 51.2 56.3 42.6 34.3 35.8 28.9 3.4 3.4 3.4 3.5 44.3 44.9 48.6 53.5 41.3 33.2 34.7 27.7 3.7 3.7 3.8 3.8 41.8 42.4 46.0 50.7 39.9 32.0 33.6 26.7 4.1 4.1 4.2 4.2 39.6 39.8 43.1 47.6 38.3 30.7 32.3 25.5 4.6 4.6 4.6 4.7 38.2 37.1 40.1 44.2 35.7 29.5 31.0 24.3 5.1 5.0 5.1 5.1 34.6 34.1 36.9 40.5 33.8 28.2 29.7 22.9 5.6 5.6 5.6 5.6 62 (19.7) 60.0 57.6 4.4 57.4 56.3 4.8 55.0 55.0 5.2 52.5 52.5 5.8 49.7 49.7 6.4 46.4 46.4 7.0 62 (19.7) 48.1 45.8 3.4 45.6 44.3 3.8 44.2 43.0 4.2 41.5 40.0 4.6 38.7 38.2 5.1 36.1 35.6 5.6 50XP 67 (19.4) 52.5 38.4 3.4 49.9 37.3 3.8 47.0 36.1 4.2 44.0 34.8 4.6 40.8 33.5 5.1 37.5 31.9 5.6 63* (17.2) 60.8 55.4 4.4 58.1 54.2 4.9 55.3 52.9 5.3 52.4 51.6 5.8 49.7 49.7 6.4 46.4 46.4 7.0 67 (19.4) 64.9 47.1 4.5 61.9 45.8 5.0 58.7 44.5 5.5 55.4 43.2 6.0 51.8 41.8 6.6 47.9 40.2 7.2 2000/0.01 63* (17.2) 48.7 36.8 3.4 46.1 35.5 3.8 43.7 34.6 4.1 40.8 33.2 4.6 37.9 31.8 5.1 34.8 30.2 5.6 1600/0.08 72 (22.2) 70.8 36.8 4.6 67.4 35.6 5.0 64.1 34.4 5.5 60.2 33.0 6.1 57.0 31.7 6.6 52.2 29.7 7.2 72 (22.2) 57.8 30.6 3.5 54.8 29.4 3.8 51.8 28.3 4.2 48.5 27.0 4.7 45.0 25.8 5.1 41.2 24.4 5.6 15 = 1.10 x cfm Sensible capacity (Btuh) air leaving evaporator coil (hlwb) Wet---bulb temperature corresponding to enthalpy = tedb --- hlwb = hewb --4.5 x cfm total capacity (Btuh) 50XP Where: hewb = Enthalpy of air entering evaporator coil 4. The SHC is based on 805 F (26.6_C) edb temperature of air entering evaporator coil. Below 80_F (26.6_C) edb, subtract (corr factor x cfm) from SHC. Above 80_F (26.6_C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb + 80). 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. tlwb tldb COOLING NOTES: 1. Ratings are net; they account for the effects of the evaporator ---fan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. The following formulas may be used: * At 75°F (24°C) entering dry bulb---Tennessee Valley Authority (TVA) rating conditions; all others at 80°F (27°C) dry bulb. LEGEND BF— Bypass Factor edb— Entering Dry ---Bulb Ewb— Entering Wet---Bulb kW — Total Unit Power Input SHC— Sensible Heat Capacity (1000 Btuh) TC — Total Capacity (1000 Btuh) (net) rh—Relative Humidity PERFORMANCE DATA (CONT) PERFORMANCE DATA (CONT) Economizer 1--in. Filter Pressure Drop (IN. W.C.) UNIT50XP 024-- 036 042-- 060 PRESSURE DROP 0.20 0.25 Multiplication Factors HEATER kW RATING VOLTAGE DISTRIBUTION V/3/60 200 208 230 240 240 MULTIPLICATION FACTOR 0.69 0.75 0.92 1.00 50XP Filter Pressure Drop Table (IN. W.C.) FILTER SIZE in. (mm) 20X20X1 (508X508X25) 20X24X1 (508X610x25) 24X30X1 (610X762x25) 500 600 700 800 900 1000 1100 1200 1300 CFM 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 0.05 0.07 0.08 0.10 0.12 0.13 0.14 0.15 — — — — — — — — — — — — — — 0.09 0.10 0.11 0.13 0.14 0.15 0.16 — — — — — — — — — — — — — — 0.07 0.08 0.09 0.10 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 — Electric Heat Pressure Drop Tables (IN. W.C.) Small Cabinet: 024--036 CFM STATIC 500 0.00 0.00 0.00 0.00 5 kW 7.5 kW 10 kW 15 kW 600 0.00 0.00 0.00 0.00 700 0.00 0.00 0.00 0.00 800 0.00 0.00 0.00 0.02 900 0.00 0.00 0.00 0.04 1000 0.00 0.00 0.02 0.06 1100 0.00 0.02 0.04 0.08 1200 0.00 0.03 0.06 0.10 1300 0.02 0.05 0.07 0.12 1400 0.04 0.07 0.09 0.14 1500 0.06 0.08 0.10 0.16 1600 0.07 0.09 0.11 0.18 Large Cabinet: 042--060 STATIC 1100 0.00 0.00 0.00 0.00 0.02 5 kW 7.5 kW 10 kW 15 kW 20 kW 1200 0.00 0.00 0.00 0.02 0.03 1300 0.00 0.01 0.01 0.03 0.04 1400 0.01 0.02 0.02 0.04 0.05 1500 0.02 0.03 0.03 0.05 0.06 1600 0.03 0.04 0.04 0.06 0.07 CFM 1800 0.05 0.06 0.06 0.08 0.09 1700 0.04 0.05 0.05 0.07 0.08 1900 0.06 0.07 0.07 0.09 0.10 2000 0.07 0.08 0.08 0.10 0.11 2100 0.08 0.09 0.09 0.11 0.12 2200 0.09 0.10 0.10 0.12 0.13 2300 0.10 0.11 0.11 0.13 0.14 2400 0.11 0.12 0.12 0.14 0.15 2500 0.12 0.13 0.13 0.15 0.16 ECM Dry Coil Airflow--Small Cabinet CFM ADJUST PIN SELECT EXTERNAL STATIC PRESSURE RANGE COOLING COOLING DEHUMIDIFY COOLING COOLING DEHUMIDIFY COOLING COOLING DEHUMIDIFY UNIT SIZE 024 030 036 LO PIN NOM PIN HI PIN 0.0-- 0.39 0.4-- 0.69 0.7-- 1.0 0.0-- 0.39 0.4-- 0.69 0.7-- 1.0 0.0-- 0.39 0.4-- 0.69 0.7-- 1.0 800 715 1010 890 1110 990 725 670 920 845 1025 960 --825 795 970 910 885 715 1105 890 1235 990 805 695 1030 865 1175 975 730 645 930 825 1115 940 990 795 1255 1010 1400 1125 930 775 1160 980 1355 1110 855 745 1050 925 1280 1085 ECM Dry Coil Airflow--Large Cabinet CFM ADJUST PIN SELECT EXTERNAL STATIC PRESSURE RANGE COOLING COOLING DEHUMIDIFY COOLING COOLING DEHUMIDIFY COOLING COOLING DEHUMIDIFY UNIT SIZE 042 048 060 LO PIN 0.1-- 1.0 1100 980 1260 1120 1575 1400 NOM PIN 0.1-- 1.0 1225 980 1400 1120 1750 1400 NOM PIN 0.1-- 1.0 1410 1125 1610 1290 2010 1610 Wet Coil Pressure Drop (IN. W.C.) Unit Size 024 030 036 042 048 060 600 0.005 700 0.007 0.007 800 0.010 0.010 900 0.012 0.012 0.019 1000 0.015 0.015 0.023 0.014 Standard CFM (S.C.F.M) 1300 1400 1500 1100 1200 0.018 0.027 0.017 0.021 0.032 0.020 0.027 0.024 0.037 0.024 0.032 16 0.042 0.027 0.036 0.047 0.031 0.041 0.029 1600 1700 1800 1900 2000 2100 0.035 0.046 0.032 0.039 0.052 0.036 0.043 0.057 0.040 0.063 0.045 0.068 0.049 0.053 TYPICAL PIPING AND WIRING ROOF-MOUNTING CURB ROOF RETURN-AIR FLEXIBLE DUCT 50XP SUPPLY-AIR FLEXIBLE DUCT CONCENTRIC DIFFUSER BOX (FIELD-SUPPLIED) CEILING C00023 INDOOR THERMOSTAT RETURN AIR FROM POWER SOURCE TOP COVER DISCONNECT PER NEC* *NEC - NATIONAL ELECTRICAL CODE C00063 17 APPLICATION DATA Condensate trap — A 2--in. (51 mm) condensate trap must be field supplied. 1” (25 mm) MIN. TRAP OUTLET 2” (51 mm) MIN. 50XP A08001 Ductwork — Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with flanges. To convert a unit to downflow discharge — Units are equipped with factory--installed inserts in the downflow openings. Removal of the inserts is similar to removing an electrical knock--out. Leave on duct covers to seal the horizontal discharge openings in the unit. Units installed in horizontal discharge orientation do not require duct covers. Maximum cooling airflow — To minimize the possibility of condensate blow--off from the evaporator, airflow through the units should not exceed 450 cfm per ton. Minimum cooling airflow — Minimum cooling airflow is 350 cfm per ton for standard cooling modes. Airflow can be lower in certain modes when humidity removal is an issue. Minimum cooling operating outdoor air temperature — All standard units have a minimum outdoor operating temperature of 55_F (13_C). With accessory low ambient temperature kit, units can operate at temperatures down to 0_F (--17_C). Maximum cooling operating outdoor air temperature — Maximum outdoor operating air temperature is 125_F (52_C). 18 ELECTRICAL DATA NOMINAL V--- PH --- HZ VOLTAGE RANGE COMPRESSOR OFM IFM MIN MAX RLA LRA FLA FLA 50XP-024 208/230-1-60 187 253 13.5 61.0 0.8 4.3 50XP-030 208/230-1-60 187 253 15.9 73.0 0.8 4.3 208/230-1-60 187 253 16.9 83.0 0.8 6.8 208/230-3-60 187 253 12.2 77.0 0.8 6.8 208/230-1-60 187 253 22.4 105.0 0.8 6.8 208/230-3-60 187 253 15.4 88.0 0.8 6.8 208/230-1-60 187 253 21.3 109.0 1.6 6.8 208/230-3-60 187 253 14.7 91.0 1.6 6.8 208/230-1-60 187 253 27.0 145.0 1.6 9.1 208/230-3-60 187 253 19.2 137.0 1.6 9.1 50XP-036 50XP-042 50XP-048 50XP-060 ELECTRIC HEAT NOMINAL KW FLA -/3.8/5 5.4/7.2 7.5/10 -/3.8/5 5.4/7.2 7.5/10 11.3/15 -/3.8/5 5.4/7.2 7.5/10 11.3/15 -/5 10 15 -/3.8/5 5.4/7.2 7.5/10 11.3/15 15/20 -/3.8/5 7.5/10 11.3/15 15/20 -/3.8/5 5.4/7.2 7.5/10 11.3/15 15/20 -/3.8/5 7.5/10 11.3/15 15/20 -/3.8/5 5.4/7.2 7.5/10 11.3/15 15/20 -/3.8/5 7.5/10 11.3/15 15/20 -/18.1/20.8 26/30 36.1/41.7 -/18.1/20.8 26/30 36.1/41.7 54.2/62.5 -/18.1/20.8 26/30 36.1/41.7 54.2/62.5 -/10.4/12 20.8/24.1 31.3/36.1 -/18.1/20.8 26/30 36.1/41.7 54.2/62.5 72.2/83.3 -/10.4/12 20.8/24.1 31.3/36.1 41.6/48 -/18.1/20.8 26/30 36.1/41.7 54.2/62.5 72.2/83.3 -/10.4/12 20.8/24.1 31.3/36.1 41.6/48 -/18.1/20.8 26/30 36.1/41.7 54.2/62.5 72.2/83.3 -/10.4/12 20.8/24.1 31.3/36.1 41.6/48 POWER SUPPLY MAX FUSE or MCA CKT BKR 22.0/22.0 30/30 27.9/31.4 30/35 37.9/42.9 40/45 50.5/57.5 60/60 23.6/23.6 30/30 27.9/31.4 30/35 37.9/42.9 40/45 50.5/57.5 60/60 73.1/83.5 26.9/26.9 35/35 31.1/34.5 35/35 41.0/46.0 45/50 53.6/60.6 --76.2/86.6 --23.0/23.0 30/30 23.0/23.5 30/30 34.6/38.6 35/35 47.6/53.6 50/60 30.9/30.9 45/45 31.1/34.5 45/45 41.0/46.0 45/50 53.6/60.6 --76.2/86.6 --98.8/112.7 --27.0/27.0 35/35 27.0/27.0 35/35 34.6/38.6 35/35 47.6/53.6 50/60 60.5/68.5 --33.9/33.9 45/45 33.9/34.5 45/45 41.0/46.0 45/50 53.6/60.6 --76.2/86.6 --98.8/112.7 --26.7/26.7 35/35 26.7/26.7 35/35 34.6/38.6 35/35 47.6/53.6 50/60 60.5/68.5 --44.3/44.3 60/60 44.3/44.3 60/60 44.3/48.9 60/60 56.5/63.5 --79.1/89.5 --101.6/115.5 --33.0/33.0 40/40 33.0/33.0 40/40 37.4/41.4 40/45 50.5/56.5 60/60 63.3/71.3 --- 460-3-60. 452 v 464 v 455 v 452 1371 *Heater capacity (kW) based on heater voltage of 208v, 240v, & 480v. If power distribution voltage to unit varies from rated heater voltage, heater kW will vary accordingly. 457 457 452 464 457 457 455 5 7 2 7 7 457 1.53 19 464 455 MOCP ----------------80/90 ------60/70 80/90 --------------60/70 80/90 100/125 --------70/70 ------60/70 80/90 100/125 --------70/70 ------60/70 80/90 100/125 --------70/80 50XP UNIT 50XP TYPICAL WIRING SCHEMATIC 208/230--1--60 A08460 20 50XP TYPICAL WIRING SCHEMATIC 208/230--3--60 A08461 21 CONTROLS Operating sequence Heating — If accessory electric heaters are installed, on a call for heat, circuit R--W is made through the thermostat contacts. Circuit R--G is made which energizes the IFM. If the heaters are staged, then the thermostat closes a second set of contacts (W2) when second stage is required. When thermostat is satisfied, contacts open, deenergizing the heater relay. After a preselected delay, the IFM shuts off. If the thermostat fan selector switch is in the “ON” position, the IFM will run continuously at speed selected on Easy Select Board. NOTE: On units with a Time Guard® II device: Once the compressor has started and then stopped, it cannot be restarted again until 5 minutes have elapsed. The indoor blower operation with a call for fan operation (G) in cooling mode will perform by the on/off delay profile selected at start up on the Easy Select Board. 50XP Cooling — When the system thermostat calls for cooling, 24 V is supplied to the “Y” and “G” terminals of the thermostat. This completes the circuit to the contactor coil (C) and indoor fan board. The normally open contacts of C close and complete the circuit to compressor motor (COMP) and to outdoor (condenser) fan motor (OFM). Both motors start instantly. The IFM starts according to the selection pin set--up on the Easy Select Board. On the loss of the thermostat call for cooling, 24 V is removed from both the “Y” and “G” terminals (provided the fan switch is in the “AUTO” position) de--energizing the compressor contactor and opening the contacts supplying power to compressor/OFM. After a preselected delay, the IFM shuts off. If the thermostat fan selector switch is in the “ON” position, the IFM will run continuously at speed selected on Easy Select Board 22 Packaged Electric Cooling Unit Constant Volume Application HVAC Guide Specifications Size Range: 2 to 5 Tons, Nominal Cooling Model Number: 50XP Part 1 — General SYSTEM DESCRIPTION Outdoor rooftop mounted or ground mounted, electric cooling unit utilizing a hermetic compressor for cooling duty and optional electric heating. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. Condenser fan/coil section shall have a draw--thru design with vertical discharge for minimum sound levels. QUALITY ASSURANCE A. Unit shall be rated in accordance with ARI Standards 210/240 and 270. B. Unit shall be designed in accordance with UL Standard 1995. C. Unit shall be manufactured in a facility registered to ISO 9001 manufacturing quality standard. D. Unit shall be UL listed and c--UL certified as a total package for safety requirements. E. Roof curb shall be designed to conform to NRCA Standards. F. Insulation and adhesives shall meet NFPA 90A requirements for flame spread and smoke generation. G. Cabinet insulation shall meet ASHRAE Standard 62P. DELIVERY, STORAGE AND HANDLING Unit shall be stored and handled per manufacturer’s recommendations. Part 2 — Products EQUIPMENT A. General: Factory--assembled, single--piece, cooling unit. Contained within the enclosure shall be all factory wiring, piping, controls, refrigerant charge with R--410A refrigerant, and special features required prior to field start--up. B. Unit Cabinet: 1. Unit cabinet shall be constructed of phosphated, zinc--coated, pre--painted steel capable of with--standing 500 hours in salt spray. 2. Normal service shall be through a single removable cabinet panel. 3. The unit shall be constructed on a rust proof unit base that has an externally trapped, integrated sloped drain pan. 4. Evaporator fan compartment top surface shall be insulated with a minimum 1/2--in. (13 mm) thick, flexible fiberglass insulation, coated on the air side and retained by adhesive and mechanical means. The evaporator wall sections will be insulated with a minimum semi--rigid foil--faced board capable of being wiped clean. Aluminum foil--faced fiberglass insulation shall be used in the entire indoor air cavity section. 5. Unit shall have a field--supplied condensate trap. C. Fans: 1. The evaporator fan shall be direct--drive variable speed motor and control, as shown on equipment drawings. 2. Fan wheel shall be made from steel, be double--inlet type with forward curved blades with corrosion resistant finish. Fan wheel shall be dynamically balanced. 3. Condenser fan shall be direct drive propeller type with aluminum blades riveted to corrosion resistant steel spiders, be dynamically balanced, and discharge air vertically. D. Compressor: 1. Fully hermetic compressors with factory--installed vibration isolation. 2. Scroll compressors shall be standard on all units. E. Coils: Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless copper tubes with all joints brazed. (Copper/copper and vinyl--coated construction available as option). Tube sheet openings shall be belled to prevent tube wear. F. Refrigerant Components: Refrigerant expansion device shall be of the TXV (thermostatic expansion valve) type. G. Filters: Filter section shall consist of field--installed, throwaway, 1--in. (25 mm) thick fiberglass filters of commercially available sizes. H. Controls and Safeties: 1. Unit controls shall be complete with a self--contained low voltage control circuit. 2. Units shall incorporate an internal compressor protector that provides reset capability. 3. Unit shall provide High and Low/Loss--of--Charge Pressure Safety Protection. I. Operating Characteristics: 1. Unit shall be capable of starting and running at 125_F (51_C) ambient outdoor temperature,exceeding maximum load criteria of ARI Standard 210. 2. Compressor with standard controls shall be capable of operation down to 55_F (13_C) ambient outdoor temperature. 3. Indoor Fan on/off delay profile is selected (for cooling) on the Easy Select board. J. Electrical Requirements: All unit power wiring shall enter the unit cabinet at a single location. K. Motors: 1. Compressor motors shall be of the refrigerant--cooled type with line--break thermal and current overload protection. 2. All fan motors shall have permanently lubricated bearings, and inherent, automatic reset, thermal overload protection. 3. Condenser fan motor shall be totally enclosed. L. Grille: 1. Louvered Grille: Louvered grille shall be standard on all units. 23 50XP GUIDE SPECIFICATIONS 50XP GUIDE SPECIFICATIONS (CONT) 6. Low Ambient Package: Shall consist of a solid--state control and condenser coil temperature sensor for controlling condenser--fan motor operation, which shall allow unit to operate down to 0_F (--18_C) outdoor ambient temperature when properly installed. 7. Filter Rack Kit: Shall provide filter mounting for downflow or horizontal applications. 8. Square--To--Round Duct Transitions (024--048): Shall have the ability to convert the supply and return openings from rectangular to round. (024--048 only) 9. Compressor Protection: Solid--state control shall protect compressor by preventing “short cycling.“ 10. Crankcase Heater: Shall provide anti--floodback protection for low--load cooling applications. 11. Electric Heaters: a. Electric heater shall be availabel as a field--installed option. b. Heater elements shall be open wire type, adequately supported and insulated with ceramic bushings. c. Electric heater packages must provide single point power connection capability. 12. Compressor Start Kit (single phase units only): Shall provide additional starting torque for single--phase compressors. M. Special Features: 1. Coil Options: Shall include factory--installed optional tin--plated indoor, copper/copper and vinyl--coated refrigerant coils. 2. Economizer: a. Economizer controls capable of providing free cooling using outside air. b. Equipped with low leakage dampers not to exceed 3% leakage, at 1.0 IN. W.C. pressure differential. c. Spring return motor shuts off outdoor damper on power failure. 3. Flat Roof Curb: Curbs shall have seal strip and a wood nailer for flashing and shall be installed per manufacturer’s instructions. 4. Manual Outdoor Air Damper: Package shall consist of damper, birdscreen, and rainhood which can be preset to admit outdoor air for year--round ventilation. 5. Thermostat: To provide for one--stage heating and cooling in addition manual or automatic changeover and indoor fan control. Copyright 2008 Carrier Corp. D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/08 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 24 Catalog No: 50XP---05PD Replaces: 50XP--- 4PD
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:11:17 11:36:55-05:00 Create Date : 2008:11:17 11:31:53-05:00 Metadata Date : 2008:11:17 11:36:55-05:00 Format : application/pdf Title : 50XP-05PD Creator : bact2wt Document ID : uuid:34f4a40f-cff6-4de1-a5fc-b80e39b4992d Instance ID : uuid:db6ae8f6-091f-4da2-9c7e-74930df54500 Page Count : 24 Author : bact2wtEXIF Metadata provided by EXIF.tools