Carrier Outdoor Temperature Sensor Tstatccsen01 Users Manual
tstatccsen01 13ef757b-e13c-411f-8c28-bd0aa760c0ec Carrier Home Security System TSTATCCSEN01 User Guide |
2015-01-24
: Carrier Carrier-Outdoor-Temperature-Sensor-Tstatccsen01-Users-Manual-310957 carrier-outdoor-temperature-sensor-tstatccsen01-users-manual-310957 carrier pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
TSTATCCSEN01 Outdoor Temperature Sensor Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Read and follow manufacturer instructions carefully. Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installation may damage thermostat sensor. . Recognize safety information. This is the safety-alert symbol When you see this symbol on the equipment and in the instruction manual, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. INTRODUCTION The remote temperature sensor is an accessory for all Carrier thermostats, except the non-programmable A/C versions. It allows the temperature at a remote location to be displayed on the thermostat. PERFORMING THE INSTALLATION Once the mounting location has been selected, route the interconnecting wiring through the building between thermostat and outdoor sensor. The exit point from inside to outside will be the location of the outdoor sensor. The location of the wire nuts will be either inside or outside of wall depending on whether or not a box is used. Allow sufficient wire length for some excess on each end. IF AN OUTLET BOX IS USED: (See Fig. 1.) Drill a suitable hole in the building wall at selected sensor location. Route interconnecting wire through building wall. Remove rear knockout from electric box, route wire through box, and attach box to wall with supplied wood screws. Cut and strip wires to a reasonable length and connect with supplied wire nuts. Polarity is unimportant. Seal wires where they exit building with a suitable exterior caulk. Fasten cover to box with supplied sheet metal screws. FIELD-SUPPLIED OUTLET BOX SENSOR EXTERIOR WALL MOUNTING CONSIDERATIONS Choose a location for the outdoor sensor after considering the following: 1) A wiring route must be planned between thermostat and location of outdoor sensor, prior to installation. 2) A sensor located in direct sunlight will not read properly while the sun is shining on it. 3) A high location under an eave is ideal because it is protected from sun, weather, and people. 4) The sensor can be mounted directly to a wall using provided screws and standoffs or can be used as a cover for a standard electric outlet box (not supplied). WIRING SELECTION: A pair of conductors must be selected to run between mounted sensor and thermostat. Conductors must be rated NEC Class 1. Thermostat and common bell wire have this rating. METAL SCREWS MOUNTING TO OUTLET BOX: A standard electrical box (not included) may be used with the sensor plate as its cover. This provides room inside box for wire nut connection between sensor wires and wiring run to the thermostat. A94409 Fig. 1—Mounting to Outlet Box USING SENSOR PLATE: Attaching the plate directly to the outside wall simplifies mounting and requires less space, but the wire nut transitions to the thermostat wiring now need to be made within the wall. This may be difficult in some installations. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 92-33TS-TA13C Printed in U.S.A. Form TSTAT-3SI Pg 1 12/15/94 Replaces: New Tab misc. misc. IF PLATE IS ATTACHED DIRECTLY TO WALL: (See Fig. 2.) Drill a suitable hole through the wall at selected sensor location. Route sensor wires through wall, making sure they are accessible from the inside. Use provided spacers to stand off plate from wall. Mount the sensor plate loosely to wall with only 1 screw so that access to hole is preserved for application of caulking. Fill hole with a suitable exterior caulking compound. Then insert second screw and tighten both screws carefully. SENSOR SPACERS EXTERIOR WALL From inside, locate sensor wires and wires from thermostat. Cut and trim thermostat wires to an appropriate length and connect with supplied wire nuts. It may be advisable to retain thermostat wire with a clamp or wire staple ahead of wire nuts to prevent a pull on this wire from damaging the more delicate sensor connections. THERMOSTAT CONNECTION: Turn OFF all power to system. The thermostat display will go blank. Open thermostat at rear hinge to access connector blocks. Route and connect wires at thermostat carefully to minimize amount of wire between wall and thermostat. Strip ends only 1/4 in. to prevent a possible short between wires at the thermostat. Attach wires to S1 and S2 terminals. Polarity is unimportant. Route wires behind thermostat so that hinge can close properly. When wiring is completed and thermostat closed, restore power to system. Refer to Homeowners manual for procedure to display remote temperature. Copyright 1994 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 WOOD SCREWS Fig. 2—Mounting Directly to Wall A94410 tstat3si Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 92-33TS-TA13C Printed in U.S.A. Form TSTAT-3SI Pg 2 12/15/94 Replaces: New Tab misc. misc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : 3.1-701 Creation Date--Text : Tuesday, 31 January, 1995 at 09:47am Producer : Acrobat Distiller 1.02 for Windows Keywords : Format : application/pdf Title : Description : Creator : Carrier Corporation Subject : Modify Date : 2005:11:10 10:15:05-05:00 Create Date : 2005:11:10 10:15:05-05:00 Metadata Date : 2005:11:10 10:15:05-05:00 Document ID : uuid:16d86ace-e5e8-4986-b855-4550be92086e Instance ID : uuid:c90714ec-1c7e-4469-9351-682ea7a3550d Page Count : 2 Author : Carrier CorporationEXIF Metadata provided by EXIF.tools