Removing
Gently Pull the lower edge
of the control gently out
from the holder.
Control Storage
Angle control in top first in
the holder until the unit
can be gently pushed back
and snapped onto the
bottom rim.
WOOD
SCREW 1”
Note: The wall anchors and
6-32 x 1” screws may be used
in situations where mounting
to a stud is not possible. Use
the inner mounting holes.
After securing the anchor, dis-
card the anchor’s pointed
screws and use the 6-32 de-
cor ovalhead screws supplied.
VERSA•TOUCH STORING CONTROL IN HOLDER
DECOR OVALHEAD SCREW
6-32 X 1”
ANCHOR
PANHEAD
SCREW DRYWALL ANCHOR
TOP GOES
IN FIRST
Wall Installation
Step 1. Locate a
2X4 wall stud in a
convenient loca-
tion.
Step 2. Orient the
control holder as
shown over the
2X4 stud.
Step 3. Use the 1”
wood screws in ei-
ther the inner or
outer mounting
holes.
Install and tight-
en screws by hand
only.
ROCKER
TYPE
LIGHT
SWITCH
SWITCH
COVER
PLATE
STANDARD
TOGGLE
SWITCH
SWITCH
COVER
PLATE
INNER
MOUNTING
HOLES
CONTROL
HOLDER
OUTER
MOUNTING
HOLES
SCREW
6-32 X 1”
(2)
SCREW
6-32 X 3/8
(2)
WOOD
SCREW
1”
(2)
DRYWALL
ANCHOR
6-32
(2)
REMOVE TABS
CAUTION! Do not use with wall dimmer.
9V BATTERY
W-42
CONTROL
Rocker Light Switch
Step 1. Break off the two tabs by pushing outward.
Step 2. Remove the two screws holding the switch cover plate. Do
not remove the cover plate.
Step 3. Orient the control holder as shown and line up the two outer
mounting holes with those on the switch.
Step 4. Install and tighten screws by hand only.
VERSA•TOUCH CONTROL HOLDER INSTALLATION
W-42
CONTROL
HOLDER
VERSA•TOUCH INSTALLATION
Standard Light Switch
Step 1. Remove the two screws holding the switch cover
plate. Do not remove the cover plate.
Step 2. Orient the control holder as shown and line up
the two inner mounting holes with those on the switch.
Step 3. Install and tighten screws by hand only.
VERSA•TOUCH BATTERY INSTALLATION GUIDE SLOTS
Install Battery
Press battery into
control aligned as
shown. Observe
proper polarity.
Replace the
battery door.
SNAP
SOCKET PLUG
Remove Battery Door
Turn control on its
front.
Twist a coin to unsnap
the door A. Lift door
away from control B
and remove C.
8
R
Changes or modifications not expressly approved in writing by Casablanca Fan Co. may void
the user’s authority to operate this equipment.
9
VERSA•TOUCH IF FAN DOES NOT WORK
If the fan is not functioning after installation:
Step 1. Check to make sure that batteries are installed correctly
in the control.
Step 2. Turn the power off to the fan (from the circuit breaker)
for at least 5 seconds.
Step 3. Turn the power back on (at the circuit breaker) and push
the Hi, Med, and Low buttons–in that order–within 20 seconds.
Step 4. The fan should now function properly.
R
SEND
SIGNAL
LED
VERSA•TOUCH CHANGING FREQUENCY SETTING
VERSA•TOUCH OPERATION
Fan Control
To start the fan. Press the selected speed button to run the fan at the desired speed.
LO Low speed
MED Medium speed
HI High speed
To turn off the fan. Press the FAN OFF button.
Airflow Direction
To reverse the airflow press the REVERSE button. Reverse operates at any speed whether fan is
on or off. The fan returns to its set speed after reversing.
Light Control
Turn the light on or off independently from the fan by pressing the LIGHT button. Keep pressing
the button in excess of 0.7 seconds, it becomes a dimmer. The light varies from ‘bright’ to ‘dim’
over approximately 8 seconds. This sequence will reverse the light when it reaches the brightest
or dimmest level if you continue to hold the LIGHT button. Release the button when the
desired level is reached.
Auto Resume
Quick (pressing less than 0.7 seconds) on/off operation of the LIGHT button maintains the
desired brightness level set previously.
You will only have to change the dip switch settings in the remote if
you are using more than one fan in the same area and want to control
them separately.
Step 1. At the circuit breaker or fuse box, turn the power off for the fan
you want to change.
Step 2. Open the battery door of the Versa•Touch control and remove
the batteries.
Step 3. Change the dip switch settings, assuring that they are different
from the previously installed Versa•Touch fan.
Step 4. Re-install the batteries and the battery door on the control.
Step 5. At the circuit breaker or fuse box, turn the power back on for
the fan whose frequency you are changing.
Step 6. Within 20 seconds of restoring power, push the Hi, Med, and Lo
buttons (in that order).
9
Note: All fans leave the factory set to ‘00000’.
WITHIN 20 SECONDS OF TURNING
THE FAN ON, PRESS IN THIS
ORDER TO SET NEW FREQUENCY:
1. HI
2. MED
3. LO
123
123
CIRCUIT BREAKER
OR FUSE BOX
PRESS IN THIS ORDER TO SET NEW
FREQUENCY:
1. HI
2. MED
3. LO
DIP SWITCH
SET TO ‘01001’
DIP SWITCH
SET TO ‘10000’
VERSA•TOUCH
CONTROL
(BACK)
Note: You may want to label your controls to
assure you do not mix them up.
WARNING: Do not turn the power off at the circuit breaker,
then back on, for the previously installed Versa•Touch fan(s),
as you may inadvertantly change the frequency settings for
it as well.
10 10
TROUBLESHOOTING
Before Requesting Service: Please follow this troubleshooting guide before contacting your dealer for assistance.
Caring for Finishes: For cleaning, a soft brush or lint-free cloth
should be used to prevent scratching the finish. A vacuum cleaner
brush nozzle can remove heavier dust. Surface smudges or an accu-
mulation of dirt and dust can easily be removed by using a mild
detergent and slightly dampened soft cloth. An antistatic agent
may be used, but never use abrasive cleaning agents. These will
damage the finish. Painted and high-gloss blades may be cleaned
in the same manner.
Blades: Wood finish blades should be cleaned with a furniture pol-
ishing cloth. Occasionally, a light coat of furniture polish may be
applied for added protection and beauty.
Never Lubricate this Fan!
The precision motor at the heart of your Casablanca fan features
sealed bearings that are lubricated for life. Do not attempt to oil
the motor.
Changing Light Bulbs
Be sure to turn power to the fan OFF at the wall switch or circuit
breaker before changing light bulbs. Replace bulbs with same type
as removed from the fixture. Each fan is rated for a maximum TOTAL
wattage of lighting.
Exceeding the rated maximum allowable wattage for the fan will
burn out the fan electronics module and void the warranty.
PROBLEM POSSIBLE REMEDIES
PROBLEM POSSIBLE REMEDIES..
FAN WILL NOT START •Check main circuit fuses, circuit breakers, or wall switch position. Check all wire connections, making
sure the power is turned off during this inspection.
•Pin connectors are not making good contact. Check the connections in the switch housing and under the
top cover.
•Battery weak - install fresh battery.
•Fan receiver defective - replace.
•Check the frequency setting: Turn power off, at the circuit breaker, only for the fan not functioning for
at least 5 seconds; turn the power back on; within 20 seconds press the Hi, Med, and Lo buttons (in that
order) to set the frequency of the fan to the control. See Page 9.
FAN WOBBLES OR SHAKES •Be sure canopy pin is properly set into the slot on the ball.
EXCESSIVELY •Check that bladeholders have not been bent during installation and blades are balanced.
•Hanger bracket and/or ceiling outlet are loosely attached: Make sure that the hanger bracket is tightly
attached to the ceiling outlet box. Make sure that the downrod assembly is secured firmly
•Downrod is loosely attached to downrod base: Make sure that all screws are securely tightened
FAN NOISY DURING •Check and tighten light fixture retaining screws, glass shade screws and/or the light bulb(s).
OPERATION •Tighten canopy screws and mounting plate assembly. Check that the wire nuts inside the canopy and
switch housing are not touching the metal parts or have fallen off the wire splices. Tighten as necessary.
•Tighten blade holders to flywheel (or direct drive motor)/and blade to bladeholder screws.
•Make sure all screws in the motor housing are snug, but not overly tight. Defective bulb: Replace bulb.
DOES NOT RUN ON •If new, “break-in” may be required - run at higher speed for several days.
LOW SPEED
BATTERY LIFE •Not using Alkaline batteries: Replace with Alkaline batteries.
SEEMS SHORT
VERSA•TOUCH
LIGHT O.K., NO FAN: Pin connectors are not making good contact, check 9 pin connector under top cover. FAN O.K., NO LIGHT; Defective
receiver; Replace receiver. Defective motor; Replace motor. Broken socket; Replace socket. Defective receiver; Replace Receiver. FAN AND
LIGHT ON FULL, NO CONTROL; Defective receiver; Replace Receiver. MISSING ONE SPEED: Defective receiver; ReplaceReceiver. FAN DOESN’T
CHANGE SPEED, LIGHT O.K.: Replace receiver. FAN O.K., LIGHT NOT DIM: Defective receiver; Replace Receiver. NO REVERSE: Defective
receiver; Replace Receiver. FAN OPERATES ONLY WHEN TRANSMITTER IS CLOSED: Check antenna wire is not touching metal plate. FAN
STARTS WORKING BY ITSELF: Frequency interference; Change frequency as described on Page 9.
1.This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions: (1) this device may not cause harmful interference,and (2) this device must accept any
interference received,including interference that may cause undesired operation.
2.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and,if not installed and used in accordance with the instructions,may cause
harmful interference to radio communications. However,there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or
relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect the equipment into an outlet on a circuit different from that to which the receiver is connected,
Consult the dealer or an experienced radio/TV technician for help. Note: Any changes or modifications to the transmitter or receiver not expressly approved by Casablanca Fan Company may void one’s
authority to operate this remote control.
For questions or to locate the nearest Casablanca Authorized Service Center call toll free: