Casablanca Fan CASA8T Ceiling fan remote control transmitter User Manual Versa Touch Inst 5

Casablanca Fan Company Inc Ceiling fan remote control transmitter Versa Touch Inst 5

User Manual

1©2003 Casablanca Fan Co.                         www.CasablancaFanCo.comSCREW6-32 X 1”(2)SCREW6-32 X 3/8”(2)WOODSCREW1” (2)DRYWALLANCHOR6-32 (2)12V BATTERYW-72CONTROLW-72CONTROLHOLDERVERSA•TOUCH 2 ♦ INSTALLATIONVERSA•TOUCH 2 ♦ CONTROL BRACKET INSTALLATIONStandard Light SwitchStep A. Remove the two screws holding the switch coverplate. Do not remove the cover plate.Step B. Orient the control bracket as shown and line up thetwo inner mounting holes with those on the switch.Step C. Install and tighten screws by hand only.INNERMOUNTINGHOLESCONTROLBRACKETSTANDARDTOGGLESWITCHSWITCHCOVERPLATERocker Light SwitchStep A. Break off the two tabs by pushing outward.Step B. Remove the two screws holding the switch coverplate. Do not remove the cover plate.Step C. Orient the control bracket as shown and line up thetwo inner mounting holes with those on the switch.Step D. Install and tighten screws by hand only.OUTERMOUNTINGHOLESCONTROLBRACKETROCKERTYPELIGHTSWITCHSWITCHCOVERPLATEWall InstallationStep A. Locate a 2x4 wallstud in a convenientlocation.Step B. Orient the controlbracket as shown over the2x4 stud.Step C. Use the 1” woodscrews in either the inneror outer mounting holes.Install and tighten screwsby hand only.DECOR OVALHEAD SCREW6-32 X 1”ANCHORPANHEADSCREWWOODSCREW 1”DRYWALL ANCHORNote: The wall anchors and 6-32 x 1” screws may beused in situations where mounting to a stud is not pos-sible. Use the inner mounting holes. After securing theanchor, discard the anchor’s pointed screws and use the6-32 decor ovalhead screws supplied.CAUTION! Do not use with wall dimmer.2Changes or modifications not expressly ap-proved in writing by Casablanca Fan Co. mayvoid the user’s authority to operate thisequipment.This device complies with RSS-210 of Industry Canada. Operation is subject tothe following two conditions: (1) this device may not cause interference, and(2) this device must accept any interference, including interference that maycause undesired operation of the device.PN: 8943420 Rev.A   PD: JAN03PDG
2©2003 Casablanca Fan Co.                         www.CasablancaFanCo.comSEND SIGNALLEDVERSA•TOUCH 2 OPERATIONFan ControlTo start the fan. Press the selected speed button to run the fan at the desired speed.LO=Low speed    MED=Medium speed     HI=High speedTo turn off the fan. Press the FAN OFF  button.Airflow DirectionTo reverse the airflow press the REVERSE button. Reverse operates at any speed whether fanis on or off. The fan returns to its set speed after reversing.Light ControlTurn the light on or off independently from the fan by pressing the LIGHT button.  Keeppressing the button in excess of 0.7 seconds, it becomes a dimmer. The light varies from‘bright’ to ‘dim’ over approximately 8 seconds. This sequence will reverse the light when itreaches the brightest or dimmest level if you continue to hold the LIGHT button. Release thebutton when the desired level is reached.Auto ResumeQuick (pressing less than 0.7 seconds) on/off operation of the LIGHT button maintains thedesired brightness level set previously.9VERSA•TOUCH 2 ♦ IF FAN DOES NOT WORKIf the fan is not functioning after installation:Step 1. Check to make sure that batteries are installed correctlyin the control.Step 2. Turn the power off to the fan (from the circuit breaker)for at least 5 seconds.Step 3. Turn the power back on (at the circuit breaker) and pushthe Hi, Med, and Low buttons–in that order–within 20 seconds.Step 4. The fan should now function properly.VERSA•TOUCH 2 ♦ CHANGING FREQUENCY SETTINGYou will only have to change the dip switch settings in the remote ifyou are using more than one fan in the same area and want to controlthem separately.Step 1. At the circuit breaker or fuse box, turn the power off for the fanyou want to change.Step 2. Open the battery door of the Versa•Touch control and removethe batteries.Step 3. Change the dip switch settings, assuring that they are differentfrom the previously installed Versa•Touch fan.Step 4. Re-install the batteries and the battery door on the control.Step 5. At the circuit breaker or fuse box, turn the power back on forthe fan whose frequency you are changing.Step 6. Within 20 seconds of restoring power, push the Hi, Med, and Lobuttons (in that order).Note: All fans leave the factory set to ‘00000’.WITHIN 20 SECONDS OFTURNING THE FAN ON,PRESS IN THIS ORDER TOSET NEW FREQUENCY:1. HI2. MED3. LO 123CIRCUIT BREAKEROR FUSE BOXPRESS IN THIS ORDER TO SET NEWFREQUENCY:1. HI      2. MED      3. LODIP SWITCHSET TO ‘01001’DIP SWITCHSET TO ‘10000’VERSA•TOUCH 2CONTROL(BACK)Note: You may want to label your controls toassure you do not mix them up.WARNING: Do not turn the power off at the circuit breaker,then back on, for the previously installed Versa•Touch 2fan(s), as you may inadvertantly change the frequency set-tings for it as well.LOMEDHILIGHTFANSTOPREVERSE1232
3©2003 Casablanca Fan Co.                         www.CasablancaFanCo.comBefore Requesting Service: Please follow this troubleshooting guide before contacting your dealer for assistance.PROBLEM POSSIBLE REMEDIES  PROBLEM POSSIBLE REMEDIES..FAN WILL NOT START •Check main circuit fuses, circuit breakers, or wall switch position. Check all wire connections, makingsure the power is turned off during this inspection.•Pin connectors are not making good contact. Check the connections in the switch housing and under thetop cover.•Battery weak - install fresh battery.•Fan receiver defective - replace.•Check the frequency setting:  Turn power off, at the circuit breaker, only for the fan not functioning forat least 5 seconds; turn the power back on; within 20 seconds press the Hi, Med, and Lo buttons (in thatorder) to set the frequency of the fan to the control.FAN WOBBLES OR SHAKES •Be sure canopy pin is properly set into the slot on the ball.EXCESSIVELY •Check that bladeholders have not been bent during installation and blades are balanced.•Hanger bracket and/or ceiling outlet are loosely attached:  Make sure that the hanger bracket is tightly.attached to the ceiling outlet box. Make sure that the downrod assembly is secured firmly.•Downrod is loosely attached to downrod base: Make sure that all screws are securely tightened .FAN NOISY DURING •Check and tighten light fixture retaining screws, glass shade screws and/or the light bulb(s).OPERATION •Tighten canopy screws and mounting plate assembly. Check that the wire nuts inside the canopy andswitch housing are not touching the metal parts or have fallen off the wire splices. Tighten as necessary.•Tighten blade holders to flywheel (or direct drive motor)/and blade to bladeholder screws.•Make sure all screws in the motor housing are snug, but not overly tight. Defective bulb: Replace bulb.DOES NOT RUN ON •If new, “break-in” may be required - run at higher speed for several days.LOW SPEEDBATTERY LIFE •Not using Alkaline batteries: Replace with Alkaline batteries.SEEMS SHORTVERSA•TOUCH 2• LIGHT O.K., NO FAN: Pin connectors are not making good contact, check 9 pin connector under top cover.• FAN O.K., NO LIGHT; Defective receiver; Replace receiver. Defective motor; Replace motor. Broken socket; Replace socket. Defective receiver;Replace Receiver.• FAN AND LIGHT ON FULL, NO CONTROL; Defective receiver; Replace Receiver.• MISSING ONE SPEED: Defective receiver; Replace Receiver.• FAN DOESN’T CHANGE SPEED, LIGHT O.K.: Replace receiver.• FAN O.K., LIGHT NOT DIM: Defective receiver; Replace Receiver.• NO REVERSE: Defective receiver; Replace Receiver.• FAN OPERATES ONLY WHEN TRANSMITTER IS CLOSED: Check antenna wire is not touching metal plate.• FAN STARTS WORKING BY ITSELF: Frequency interference; Change frequency as described on Page 2.For questions or to locate the nearestCasablanca Authorized Service Centercall toll free:1-888-227-2178or visit us on the web at:www.CasablancaFanCo.comTROUBLESHOOTING 21.This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:  (1) this device may not cause harmful interference,and (2) this device must accept anyinterference received,including interference that may cause undesired operation.2.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation.  This equipment generates,uses and can radiate radio frequency energy and,if not installed and used in accordance with the instructions,may causeharmful interference to radio communications. However,there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio ortelevision reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient orrelocate the receiving antenna, Increase the separation between the equipment and receiver, Connect the equipment into an outlet on a circuit different from that to which the receiver is connected,Consult the dealer or an experienced radio/TV technician for help.  Note: Any changes or modifications to the transmitter or receiver not expressly approved by Casablanca Fan Company may void one’sauthority to operate this remote control.

Navigation menu