Casablanca Fan CASA8T Ceiling fan remote control transmitter User Manual Versa Touch Inst 5
Casablanca Fan Company Inc Ceiling fan remote control transmitter Versa Touch Inst 5
User Manual
1©2003 Casablanca Fan Co. www.CasablancaFanCo.com
SCREW
6-32 X 1”
(2)
SCREW
6-32 X 3/8”
(2)
WOOD
SCREW
1” (2)
DRYWALL
ANCHOR
6-32 (2)
12V BATTERY
W-72
CONTROL
W-72
CONTROL
HOLDER
VERSA•TOUCH 2 ♦ INSTALLATION
VERSA•TOUCH 2 ♦ CONTROL BRACKET INSTALLATION
Standard Light Switch
Step A. Remove the two screws holding the switch cover
plate. Do not remove the cover plate.
Step B. Orient the control bracket as shown and line up the
two inner mounting holes with those on the switch.
Step C. Install and tighten screws by hand only.
INNER
MOUNTING
HOLES
CONTROL
BRACKET
STANDARD
TOGGLE
SWITCH
SWITCH
COVER
PLATE
Rocker Light Switch
Step A. Break off the two tabs by pushing outward.
Step B. Remove the two screws holding the switch cover
plate. Do not remove the cover plate.
Step C. Orient the control bracket as shown and line up the
two inner mounting holes with those on the switch.
Step D. Install and tighten screws by hand only.
OUTER
MOUNTING
HOLES
CONTROL
BRACKET
ROCKER
TYPE
LIGHT
SWITCH
SWITCH
COVER
PLATE
Wall Installation
Step A. Locate a 2x4 wall
stud in a convenient
location.
Step B. Orient the control
bracket as shown over the
2x4 stud.
Step C. Use the 1” wood
screws in either the inner
or outer mounting holes.
Install and tighten screws
by hand only.
DECOR OVALHEAD SCREW
6-32 X 1”
ANCHOR
PANHEAD
SCREW
WOOD
SCREW 1”
DRYWALL ANCHOR
Note: The wall anchors and 6-32 x 1” screws may be
used in situations where mounting to a stud is not pos-
sible. Use the inner mounting holes. After securing the
anchor, discard the anchor’s pointed screws and use the
6-32 decor ovalhead screws supplied.
CAUTION! Do not use with wall dimmer.
2
Changes or modifications not expressly ap-
proved in writing by Casablanca Fan Co. may
void the user’s authority to operate this
equipment.
This device complies with RSS-210 of Industry Canada. Operation is subject to
the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.
PN: 8943420 Rev.A PD: JAN03PDG
2©2003 Casablanca Fan Co. www.CasablancaFanCo.com
SEND SIGNAL
LED
VERSA•TOUCH 2 OPERATION
Fan Control
To start the fan. Press the selected speed button to run the fan at the desired speed.
LO=Low speed MED=Medium speed HI=High speed
To turn off the fan. Press the FAN OFF button.
Airflow Direction
To reverse the airflow press the REVERSE button. Reverse operates at any speed whether fan
is on or off. The fan returns to its set speed after reversing.
Light Control
Turn the light on or off independently from the fan by pressing the LIGHT button. Keep
pressing the button in excess of 0.7 seconds, it becomes a dimmer. The light varies from
‘bright’ to ‘dim’ over approximately 8 seconds. This sequence will reverse the light when it
reaches the brightest or dimmest level if you continue to hold the LIGHT button. Release the
button when the desired level is reached.
Auto Resume
Quick (pressing less than 0.7 seconds) on/off operation of the LIGHT button maintains the
desired brightness level set previously.
9
VERSA•TOUCH 2 ♦ IF FAN DOES NOT WORK
If the fan is not functioning after installation:
Step 1. Check to make sure that batteries are installed correctly
in the control.
Step 2. Turn the power off to the fan (from the circuit breaker)
for at least 5 seconds.
Step 3. Turn the power back on (at the circuit breaker) and push
the Hi, Med, and Low buttons–in that order–within 20 seconds.
Step 4. The fan should now function properly.
VERSA•TOUCH 2 ♦ CHANGING FREQUENCY SETTING
You will only have to change the dip switch settings in the remote if
you are using more than one fan in the same area and want to control
them separately.
Step 1. At the circuit breaker or fuse box, turn the power off for the fan
you want to change.
Step 2. Open the battery door of the Versa•Touch control and remove
the batteries.
Step 3. Change the dip switch settings, assuring that they are different
from the previously installed Versa•Touch fan.
Step 4. Re-install the batteries and the battery door on the control.
Step 5. At the circuit breaker or fuse box, turn the power back on for
the fan whose frequency you are changing.
Step 6. Within 20 seconds of restoring power, push the Hi, Med, and Lo
buttons (in that order).
Note: All fans leave the factory set to ‘00000’.
WITHIN 20 SECONDS OF
TURNING THE FAN ON,
PRESS IN THIS ORDER TO
SET NEW FREQUENCY:
1. HI
2. MED
3. LO 1
2
3
CIRCUIT BREAKER
OR FUSE BOX
PRESS IN THIS ORDER TO SET NEW
FREQUENCY:
1. HI 2. MED 3. LO
DIP SWITCH
SET TO ‘01001’
DIP SWITCH
SET TO ‘10000’
VERSA•TOUCH 2
CONTROL
(BACK)
Note: You may want to label your controls to
assure you do not mix them up.
WARNING: Do not turn the power off at the circuit breaker,
then back on, for the previously installed Versa•Touch 2
fan(s), as you may inadvertantly change the frequency set-
tings for it as well.
LO
MED
HI
LIGHT
FAN
STOP
REVERSE
1
2
3
2
3©2003 Casablanca Fan Co. www.CasablancaFanCo.com
Before Requesting Service: Please follow this troubleshooting guide before contacting your dealer for assistance.
PROBLEM POSSIBLE REMEDIES
PROBLEM POSSIBLE REMEDIES..
FAN WILL NOT START •Check main circuit fuses, circuit breakers, or wall switch position. Check all wire connections, making
sure the power is turned off during this inspection.
•Pin connectors are not making good contact. Check the connections in the switch housing and under the
top cover.
•Battery weak - install fresh battery.
•Fan receiver defective - replace.
•Check the frequency setting: Turn power off, at the circuit breaker, only for the fan not functioning for
at least 5 seconds; turn the power back on; within 20 seconds press the Hi, Med, and Lo buttons (in that
order) to set the frequency of the fan to the control.
FAN WOBBLES OR SHAKES •Be sure canopy pin is properly set into the slot on the ball.
EXCESSIVELY •Check that bladeholders have not been bent during installation and blades are balanced.
•Hanger bracket and/or ceiling outlet are loosely attached: Make sure that the hanger bracket is tightly.
attached to the ceiling outlet box. Make sure that the downrod assembly is secured firmly.
•Downrod is loosely attached to downrod base: Make sure that all screws are securely tightened .
FAN NOISY DURING •Check and tighten light fixture retaining screws, glass shade screws and/or the light bulb(s).
OPERATION •Tighten canopy screws and mounting plate assembly. Check that the wire nuts inside the canopy and
switch housing are not touching the metal parts or have fallen off the wire splices. Tighten as necessary.
•Tighten blade holders to flywheel (or direct drive motor)/and blade to bladeholder screws.
•Make sure all screws in the motor housing are snug, but not overly tight. Defective bulb: Replace bulb.
DOES NOT RUN ON •If new, “break-in” may be required - run at higher speed for several days.
LOW SPEED
BATTERY LIFE •Not using Alkaline batteries: Replace with Alkaline batteries.
SEEMS SHORT
VERSA•TOUCH 2
• LIGHT O.K., NO FAN: Pin connectors are not making good contact, check 9 pin connector under top cover.
• FAN O.K., NO LIGHT; Defective receiver; Replace receiver. Defective motor; Replace motor. Broken socket; Replace socket. Defective receiver;
Replace Receiver.
• FAN AND LIGHT ON FULL, NO CONTROL; Defective receiver; Replace Receiver.
• MISSING ONE SPEED: Defective receiver; Replace Receiver.
• FAN DOESN’T CHANGE SPEED, LIGHT O.K.: Replace receiver.
• FAN O.K., LIGHT NOT DIM: Defective receiver; Replace Receiver.
• NO REVERSE: Defective receiver; Replace Receiver.
• FAN OPERATES ONLY WHEN TRANSMITTER IS CLOSED: Check antenna wire is not touching metal plate.
• FAN STARTS WORKING BY ITSELF: Frequency interference; Change frequency as described on Page 2.
For questions or to locate the nearest
Casablanca Authorized Service Center
call toll free:
1-888-227-2178
or visit us on the web at:
www.CasablancaFanCo.com
TROUBLESHOOTING 2
1.This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions: (1) this device may not cause harmful interference,and (2) this device must accept any
interference received,including interference that may cause undesired operation.
2.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and,if not installed and used in accordance with the instructions,may cause
harmful interference to radio communications. However,there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or
relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect the equipment into an outlet on a circuit different from that to which the receiver is connected,
Consult the dealer or an experienced radio/TV technician for help. Note: Any changes or modifications to the transmitter or receiver not expressly approved by Casablanca Fan Company may void one’s
authority to operate this remote control.