Cattron North America 844TX Remote Crane Control User Manual 142108d CMMDPRO
Laird Controls North America Inc. Remote Crane Control 142108d CMMDPRO
Users Manual
REMOTE CONTROL AND TELEMETRY SYSTEMS
Read all Safety and Warnings before
installing and operating this system
WARNING !
142108d - CMMDPRO.pm6
Rev D. 12-24-99
REMTRON, INC. 1916 W. Mission Rd., Escondido, CA 92029-1114
PHONE 760-737-7800 FAX 760-737-7810
Radio Remote Control System
User's Manual
This manual covers the following Remtron models:
Transmitters Receivers
21T10 o21R10 o
21T14 o21R14 o
21T18 o21R22 o
21T20 o
21T23 o
21T34 o
21T44 o
21T54 o
AVERTISSEMENT !
Lire toutes les consignes de sécurité
et tous les avertissements avant
de faire fonctionner ce système.
Section 1. System Description
1.1 Introduction
1.2 Transmitter Description
1.3 Receiver Description
1.4 Options
Section 2. Installation
2.1 Installation Planning
2.2 Mounting Location
2.3 Antenna Mounting
2.4 Receiver Installation
Section 3. Troubleshooting
3.1 General
3.2 Transmitter Testing
3.3 Receiver Testing
Section 4. Maintenance
4.1 Periodic Maintenance
4.2 Transmitter & Receiver Repairs
4.3 Programming
4.4 Parts Lists
4.5 Ordering & Repairs
4.6 Warranty
Section 5. Transmitter
5.1 Transmitter Description
5.2 Transmitter Functions
5.3 Transmitter Operation
5.4 Options
5.5 Troubleshooting
5.6 Transmitter Repairs
5.7 Transmitter Specifications
Section 6. Receiver
6.1 Receiver Description
6.2 Options
6.3 Receiver Specifications
i
TABLE OF CONTENTS
ii
Failure to follow the SAFETY RULES may result in serious personal injury.
INSTALLATION
* GROUND THE RECEIVER CASE. In order to insure safety of the system, the
receiver case must be firmly connected to earth ground.
* PROVIDE A SAFETY CUTOFF SWITCH. If maintenance is required, the radio
must be disconnected from power to prevent accidental activation.
* USE PROPER WIRING. Loose or frayed wires can cause accidental activation of
machinery.
* DO NOT INSTALL IN HOT AREAS. This apparatus can be damaged by heat in
excess of 160 F.
* DO NOT INSTALL IN HIGH VIBRATION AREAS. The life of this apparatus may
be shortened through long exposure to intense shaking or vibration.
* DO NOT INSTALL IN AREAS WHERE WATER OR CONTAMINENTS CAN
ENTER THE RECEIVER. The receiver is enclosed in a NEMA 12 rated enclosure,
however direct spraying of liquids or exposure to caustic environments may result in
malfunction of the unit.
PERSONAL SAFETY
* MAKE SURE MACHINERY IS CLEAR BEFORE OPERATING. Do not activate
the remote system unless it is safe to do so.
* TURN OFF THE RECEIVER POWER BEFORE WORKING ON MACHINERY.
Always disconnect the remote system before doing any maintenance to prevent accidental
operation of the machine.
CARE
* KEEP DRY. If water or other liquids get inside, immediately dry the unit.
* KEEP ANTENNAS CLEAN. Keep antenna connections clean and free of corrosion.
WARNING !
READ ALL INSTRUCTIONS
WARNING INSTRUCTIONS
iii
Le non respect des CONSIGNES DE SÉCURITÉ peut causer des blessures sérieuses.
INSTALLATION
* RACCORDER LE BOÎTIER À LA MASSE. Pour que le système fonctionne en toute sécurité, le boîtier du
récepteur doit être solidement raccordé à la masse.
* FOURNIR UN INTERRUPTEUR DE SÉCURITÉ. Lors de travaux d’entretien du dispositif, déconnecter le
poste radio afin d’éviter une mise en marche accidentelle..
* UTILISER LES FILS APPROPRIÉS. Des fils découverts ou usés peuvent provoquer un démarrage accidentel
de la machinerie.
* NE PAS INSTALLER DANS DES ENDROITS CHAUDS. Des températures supérieures à 160 °F (71°C)
peuvent endommager l’appareil.
* NE PAS INSTALLER DANS LES ENDROITS SOUMIS À DE FORTES VIBRATIONS. L’exposition
prolongée de cet appareil à des vibrations ou des secousses intenses peut en réduire la durée de vie.
* NE PAS EXPOSER LE RÉCEPTEUR À L’EAU OU À TOUT AUTRE CONTAMINANT. Bien que le
récepteur soit entouré d’une enceinte répondant à la norme NEMA 12, l’exposition directe à un liquide ou à un
environnement caustique peut entraîner un mauvais fonctionnement de l’appareil.
SÉCURITÉ
* S’ASSURER QUE LA MACHINERIE EST DÉGAGÉE AVANT DE LA FAIRE FONCTIONNER. Ne pas
faire fonctionner le système de téléguidage à moins que cela puisse être fait en toute sécurité.
* METTRE LE RÉCEPTEUR HORS TENSION AVANT D’EFFECTEUR DES TRAVAUX SUR LA
MACHINERIE. Afin de prévenir la mise en marche accidentelle de la machinerie, toujours débrancher le système
de téléguidage avant de d’effectuer des travaux d’entretien.
ENTRETIEN
* GARDER AU SEC. Sécher immédiatement l’appareil, s’il est exposé à de l’eau ou tout autre liquide.
* GARDER LES ANTENNES PROPRES. Garder les raccordements d’antenne propres et exempts de corrosion.
AVERTISSEMENT !
LIRE TOUTES LES CONSIGNES
CONSIGNES DE SÉCURITÉ
SECTION 1: SYSTEM DESCRIPTION
1.1 INTRODUCTION
The Remtron Radio Remote Control
Systems are designed for control of industrial rated
machinery. This system complies with requirements for
operation under part 15 of the FCC rules and regulations.
This means neither the operator nor the company need
apply or register for a license to operate this equipment.
The basic system consists of a transmitter and a receiver.
The transmitter sends commands to the receiver by means
of radio waves in the 900 MHz band. Receivers operate
from 115 VAC 50/60 Hz power. Operation from 220
VAC is also available.
1.2 TRANSMITTER DESCRIPTION
The hand held transmitters are housed in
rugged cases molded from a modified polymer plastic
that stands up to extremely rugged use. A key feature of
the hand held transmitters is Remtron's patented switch
assembly for control inputs. This long life elastomeric
keypad is ergonomically designed to provide easy
operation over long periods of time with exceptional
reliability.
The lever and joystick transmitters provide
rugged yet lightweight housings that allow daylong use
without a strain on the back.
All the transmitter functions are controlled by a
microprocessor with a special memory for configuration
information. This offers a great degree of capability and
versatility while at the same time providing simplicity of
operation and maintenance.
The antenna is internal to most transmitter cases, protecting
it from damage. An indicator LED provides a quick
visual check of the transmitters status.
The transmitter sends data at two rates. When a switch
is pressed or released, three rapid commands are
generated to insure a fast system response. The transmitter
then reverts to a 1/3 rate to conserve battery power.
The crane control transmitters are designed to be very
efficient. Only two AA batteries are needed to provide
power for the 21T10 or 21T14 transmitters for a month's
normal use. Other transmitters contain additional batteries
for even longer operating time between battery changes.
An additional feature automatically shuts the transmitter
off after a preset time interval of inactivity to further
extend the battery life.
Refer to Section 5 for details on the specific transmitter
supplied with your system.
1.3 RECEIVER DESCRIPTION
The receivers consist of two
subassemblies, an RF/Decoder board and a Relay board,
mounted inside a NEMA 12 cabinet. They are equipped
with two safety relays in addition to the control relays.
RF/Decoder Board
The RF/Decoder Board contains the Radio Receiver
and the Microprocessor based control system. Signals
are received by an advanced synthesized RF module
that operates in conjunction with the microprocessor.
Commands are received on one of 87 possible
frequencies and are checked against a 16 bit address
code for proper identity and further tested against a 16
bit CRC check code. This insures only valid information
meant only for the particular unit is decoded.
The microprocessor contains a nonvolatile memory that
retains the frequency, address and particular operating
parameters for the system. The receiver is programmable
by means of PC compatible computers equipped with
an RS-232 serial port or by an independent programming
unit.
Relay board.
The Relay board contains the output relays and the power
supply. Two (2) relays form part of the safety system.
All outputs include spike snubbers to remove transient
voltages from the control lines.
For convenience, the interface terminal strips are un-
pluggable. The relay board can be easily removed without
the necessity of tracking wire numbers and positions.
1.1
The power is from 115 VAC, 50/60 Hertz. Optional
220 VAC, 50/60 Hertz, 250 VDC and other power
inputs are available. The input is protected by a fuse.
Safety Features
Controlling heavy industrial equipment requires that the
remote control system be reliable with built-in safety
features. Each transmission goes through several checks
to insure that the information being received is error free.
The safety interlocks for the crane's Main Line Contactor
(MLC) consist of the operate (OPR) and operate inhibit
(OPI) relays. These relays are controlled by the
microprocessor and by a hardware circuit. Further, one
relay has normally open contacts while the other has
normally closed contacts. This provides three levels of
safety in controlling the Main Contactor for the crane.
Over 5 million combinations of frequencies and address
codes means that no two systems will ever be produced
with the same frequency and address code, thereby
insuring that no transmitter will ever be able to
unintentionally control another crane.
Diagnostics
Even though the receivers are technically very complex,
it is exceptionally easy to maintain and troubleshoot.
Diagnostic LEDs plus an LED for each output relay are
all that are required to isolate a problem should one
occur. Both the transmitter and receiver assembly monitor
and indicate their status on a continuous basis.
1.4 OPTIONS
The following options are available on all receivers:
First Come-First Serve.
Pitch and Catch.
1.2
SECTION 1: SYSTEM DESCRIPTION
The following options are only available on the
21R22 receiver:
Stepless (proportional) Outputs:
External Hard Wire Inputs.
Extra Relay Outputs.
Pilot Lights.
Intermediate Relay Panel.
DC Power Supply.
Transfer Switch.
Refer to Section 6 for more information on the options.
SECTION 2: INSTALLATION
2.1 INSTALLATION PLANNING
To ensure reliable and safe operation of the system, the
following points must be considered before installing the
receiver assembly.
If the receiver cabinet is to be installed outdoors,
connections to the cabinet must be water tight.
If the receiver is installed in a corrosive environment,
consult the factory for optional NEMA 4X cabinets, or
house the receiver cabinet in a secondary protective
enclosure.
If the receiver is to be installed in environments where
the ambient temperature drops below -20OF (-7OC)
or rises above +160OF (+70OC) measures must be taken
to maintain the interior of the enclosure to within these
temperature limits.
2.2 MOUNTING LOCATION
Refer to section 6, Receiver Description, for the
receiver cabinet dimensions and layout. When planning
the location for mounting the receiver, observe the
following rules:
1. Allow sufficient room to swing the cabinet door
open for ease of wiring and service.
2. If the antenna is mounted directly on the receiver
cabinet, allow a minimum or 8 inches below the
cabinet for clearance. Refer to 2.3 ANTENNA
MOUNTING for more information.
3. If possible, avoid mounting the receiver on a surface
where excessive vibration or shock is present. If
this is not possible, appropriate shock mounts must
be used.
4. Allow for positive earth ground to the receiver
cabinet.
2.1
2.3 ANTENNA MOUNTING
The antenna is one of the most important parts of a radio
receiving system. The receiver is designed with a specially
tuned antenna to provide excellent operating reliability
under most conditions. Care in placing the receiver
antenna will ensure reliable operation under the most
severe conditions.
A direct "line-of-sight" between the transmitter and
receiver antenna will provide the best performance. The
radio signal will often "bounce" off metallic objects and
reach the receiver even when the antenna is directly
shielded from the transmitter.
In most cases the antenna may be mounted directly on
the receiver cabinet. If the receiver cabinet location is
not suitable and the antenna must be mounted at a remote
location, the p/n 600038 antenna kit should be used.
The remote mounting kit includes a right angle bracket
with antenna mount and a coaxial extension cable.
It is recommended that the receiver not be connected to
power lines where large transients are present. These
transients are typically caused by motors, contactors and
other large inductive loads.
2.4 RECEIVER INSTALLATION
Inspect all items to insure they have been received in
good condition. The following items are included unless
otherwise noted on the packing list.
- Transmitter
- Transmitter leather holster
- Transmitter shoulder strap
- Receiver assembly
- Receiver antenna
Mounting
Mount the receiver cabinet securely to a solid surface.
Use appropriate locking type hardware to prevent
loosening. Refer to Figure 6.1.
Mechanical
1. Connect the conduit or raceway to the receiver
cabinet and route the wiring into the cabinet.
2. The receiver cabinet should be properly grounded.
Make sure all paint is removed from the bonding
surfaces.
Electrical Connections.
If you have any questions regarding the installation, call
Remtron applications engineering.
When wiring the receiver, it is recommended the wires
be dressed along the sides of the cabinet. This will allow
easy troubleshooting and maintenance should it be
required. Some receiver cabinets are provided with a
pre-punched hole for ease of conduit installation.
Refer to the diagram in Appendix A for typical wiring
installation of the receiver. The configuration sheet
provided with your equipment will have the specific relay
assignments for your system.
1. Power/Transfer Switch Wiring.
A three pole transfer switch is normally provided with
each receiver. Wiring of this switch will depend on the
electrical configuration of your crane. Appendix A shows
wiring of the switch for a single phase crane with a
common control circuit for all motions. Additional switch
poles can be used for systems with isolated control circuits
for the motions.
The switch should be wired so that the crane's main line
contactor (MLC) is controlled by the radio OPI and
OPR relays when in the radio position, and by the pendant
2.2
WARNING !
Verify that the main input power is off
before attempting to make any
connections.
WARNING !
The safety of this system depends on the
proper wiring of this switch. Call Remtron
Applications Engineers if you have any
questions regarding the wiring of this
switch.
SECTION 2: INSTALLATION
WARNING !
The receiver cabinet must be connected
to earth ground to insure proper safety.
Verify the presence of earth ground before
operating the receiver system.
AVERTISSEMENT !
Le boîtier du récepteur doit être raccordé
à la masse afin de respecter les conditions
de sécurité. Vérifier le raccordement à la
masse avant de faire fonctionner le
récepteur.
AVERTISSEMENT !
S’assurer que l’arrivée principale de
courant soit hors tension avant de faire
quelque raccordement que ce soit.
AVERTISSEMENT !
La sécurité de ce système dépend du
raccordement approprié de cet
interrupteur. Contacter les ingénieurs de
Remtron spécialisés dans les applications
pour toute question concernant le
raccordement de cet interrupteur.
2.3
SECTION 2: INSTALLATION
WARNING !
If voltage is present at any output, the
receiver grounding is not adequate. Make
sure the cabinet is grounded before
operating the crane.
controls when the switch is in the pendant position. It
should also be wired to transfer control between the
pendant and the radio circuits.
2. Output Relay Connections.
The relay contacts are rated for 16 Amp, 240 VAC to
provide maximum reliability and life. It is recommended
that the load applied to the output circuits be limited to 5
Amps to acheive best system life. Connection to
equipment or contactors with higher voltage or current
ratings requires an auxiliary relay.
The receiver has been pre-wired for a single phase control
system. If you have multiple phase control lines you must
wire the relay commons accordingly.
Refer to the configuration sheet supplied with your system
for the specific relay assignments.
3. Power Connections.
The receiver is normally provided for 115 VAC, 50/60
Hz power. Make sure the receiver is ordered for the
correct operating voltage of your power system. Connect
line and return connections directly to the terminal strip
X1 and X2. Observing the polarity of the connections as
shown in Appendix A will prevent conflicts with any
other wiring on the crane system.
3. Installation Testing.
Before putting the system into service, the following tests
must be performed.
Apply power to the receiver and verify the power and
OPI indicators light.
Turn on the transmitter and verify the OPI indicator goes
off. Verify the OPR indicator lights and the Signal indicator
flashes.
Verify voltage is present at the receiver output to the
Main Line Contactor. Verify no voltage is present at any
of the relay outputs.
AVERTISSEMENT !
La présence de tension à l’une ou l’autre
des sorties indique un raccordement
inadéquat du récepteur à la masse.
S’assurer que le boîtier est raccordé à la
masse avant de faire fonctionner la grue.
SECTION 3: TROUBLESHOOTING
3.1 GENERAL
The following procedures are for diagnosing problems
within the system and isolating them down to the module
level. No special test equipment is required.
Both the transmitter and receiver have built in test and
diagnostic devices to aid in troubleshooting. In the event
of a system malfunction, the following guide presents a
logical approach to pinpointing the cause and quickly
restoring the equipment to operation.
Due to the rough treatment it may be subjected to, most
problems are likely to occur in the transmitter. The
transmitter should be thoroughly diagnosed before
proceeding to the receiver.
3.2 TRANSMITTER TESTING
WARNING !
When testing the transmitter, the receiver
may become active resulting in system
operation. Always assume the system is
working and will respond when testing a
transmitter.
AVERTISSEMENT !
Lors des essais du transmetteur, le récepteur
peut s’activer et entraîner la mise en marche
du système. Prendre en considération que
le système fonctionnera et répondra toujours
aux commandes lors des essais du
transmetteur.
When the transmitter is OFF the LED should be off.
Press and release the ON/ALARM button. The LED
should flash at a low rate. Press a command switch.
The LED should flash at a high rate.
If the batteries are getting low, the LED will flash on-off.
(1/2 second on and 1/2 second off) while the transmitter
is ON. The batteries should be changed at the next
convenient opportunity.
POWER
ADDRESS
SIGNAL
K1
K2
K3
K4
K5
K6
K7
K8
Figure 3.1 21R10 Receiver Diagnostics Indicators
If the LED remains on continuously there is either a
switch activated at the time the transmitter is turned on,
or a general failure that requires factory service. If the
LED remains lit continuously on power-up, insure that
no other switches are pressed while attempting to turn
the transmitter on.
If the test LED does not light at all, replace the batteries.
If this does not fix the problem, the transmitter is
inoperable and must be repaired.
3.3 RECEIVER TESTING
Receiver LEDs. Refer to Section 6 for the locations of
the decoder diagnostic LEDs inside the receiver cabinet.
On 21R10 and 21R14 receivers, the Power, Address
and Signal LEDs are on the RF/Processor board which
is mounted below the Relay board.
On 21R22 receivers the Power and Signal LEDs are
on the RF/Processor board which is mounted on top of
the Relay board.
POWER - Indicates the +12 VDC, receiver operating
voltage is present.
ADDRESS - This will flash each time a signal received
matches the decoders address. This is not used for
the 21R22 receiver.
K9
K10
K11 (OPI)
K12 (OPR)
A1
A2
A3
A4
3.1
SIGNAL - This will flash each time a signal is being
received. For the 21R22 receiver, this also indicates
a proper address was received.
K1 through Kxx - indicates the corresponding relays
are energized.
A1 through A4 (R14) or SCAN 1 through SCAN 3
(R22) - These LEDs cycle while the receiver is
scanning. When on steady, it indicates which
frequency the receiver is locked on to.
OPI and OPR - When the receiver is either in standby
or has detected a problem which requires the system
to be shut down, OPR will be off and OPI will be
on. This releases the main contactor on the crane
and prevents any operation of the crane.
During normal operation, with the transmitter turned
on, OPR will be on and OPI will be off. The main
contactor on the crane will be energized and the
decoder will be enabled to control the crane
functions.
Receiver Troubleshooting.
1. Check the POWER on indicator. If it's not lit, make
sure the power switch on the right hand side of the
receiver cabinet is in the on position.
Check the fuse on the relay board next to TB3
(TB4 on the 21R22) and replace if necessary.
Check for A.C. input power between terminals X1
and X2 of the terminal strip. If AC power is present
and the POWER on LED is not on replace the
relay board.
2. Make sure the transmitter is off. Turn the receiver
power switch off then on. Check that the OPI is
on. If no indicators come on after 1 second, the
microprocessor circuits are possibly defective.
Replace the RF/Decoder board.
3. Turn the transmitter on. If the SIGNAL LED remains
off, test the transmitter.
Verify the identity code is the same for the transmitter
and receiver.
Replace the RF/Decoder board.
4. Turn the transmitter on. If the SIGNAL LED lights
but the ADDRESS LED does not, there is a
difference between the transmitter and receiver
address code. Change the identity code on the
transmitter or receiver so that they are the same.
Refer to section 5.2 for setting the identity code.
5. If only some of the functions are operating, check
to see if the relay LED's come on for the inoperative
functions.
Check the output voltage of the respective relays
and the crane circuits.
Check the condition of the transmitter switches.
If the unit is new, check the configuration sheet to
verify the function has been programmed.
6. If you experience intermittent operation, check all
connections and make sure that the terminal strips
SECTION 3: TROUBLESHOOTING
3.2
WARNING !
Throughout the troubleshooting procedure,
work is performed within the receiver cabinet
while the system is powered. Certain points
in the cabinet contain dangerous voltages.
Use extreme caution when working inside
the cabinet with power on.
AVERTISSEMENT !
Tout au long des procédures de dépannage,
un travail est effectué dans le boîtier puisque
le système est sous tension. Certains
endroits du boîtier contiennent des tensions
dangereuses. Être extrêmement vigilant lors
de travaux à l’intérieur du boîtier lorsque le
système est sous tension.
are firmly snapped in place and that the RF/Decoder
board is firmly attached to the back of the Relay
board.
Check antenna connections.
7. If Operating Range is short, Check all antenna
connections and the transmitter operation.
On new installations, verify the receiver antenna is
placed properly. If necessary, use an antenna
mounting kit to relocate the antenna to a more
favorable location.
Replace the RF/Decoder board.
8. If any of the Contact Sense (Relay Sense) indicators
are lit (21R22 only), a difference between the
intended output command and the relay (or contactor
state occurred. This is usually caused by a failed
relay contact.
The indicator will remain illuminated even after the
transmitter is turned off. The next time the transmitter
is turned on, or if the receiver power is cycles, the
indicator will turn off unless the problem remains.
If external inputs are used for contact sensing,
examine and repair if appropriate the wiring between
the back conacts of the directional contactor and
the receiver input. Also examine the contactor for a
problem.
SECTION 3: TROUBLESHOOTING
3.3
SECTION 4: MAINTENANCE
4.1 PERIODIC MAINTENANCE
Once a year inspect the transmitter for damage to the
keypad and case.
Once a month all electrical and antenna connections
should be inspected. Make sure all antenna and electrical
connections are clean and tight and that all terminal strips
are firmly in place.
4.2 TRANSMITTER & RECEIVER REPAIRS
Refer to section 5: TRANSMITTER or Section 6:
RECEIVER for details on transmitter and receiver repairs.
4.3 PROGRAMMING
Each transmitter and receiver can be programmed for
any operating frequency, address code and specific
operating parameters required by the particular system.
Each system is fully programmed and tested before
shipment from the factory and should require
reprogramming only in the case of spares.
Programming Hardware Requirements
The RAC17, a computer based programming system, is
available that consists of an RS-232 interface box and a
computer program for PC compatible computers. This
system allows storage of configurations for each system
4.1
Table 4.1 Frequency codes
FREQ. CODE
903.0 03
903.3 04
903.6 05
903.9 06
904.2 07
904.5 08
904.8 09
905.1 0A
905.4 0B
905.7 0C
906.0 0D
906.3 0E
906.6 0F
906.9 10
907.2 11
907.5 12
907.8 13
908.1 14
908.4 15
908.7 16
909.0 17
FREQ. CODE
921.9 42
922.2 43
922.5 44
922.8 45
923.1 46
923.4 47
923.7 48
924.0 49
924.3 4A
924.6 4B
924.9 4C
925.2 4D
925.5 4E
925.8 4F
926.1 50
926.4 51
926.7 52
927.0 53
FREQ. CODE
909.3 18
909.6 19
909.9 1A
910.2 1B
910.5 1C
910.8 1D
911.1 1E
911.4 1F
911.7 20
912.0 21
912.3 22
912.6 23
912.9 24
913.2 25
913.5 26
913.8 27
914.1 28
914.4 29
914.7 2A
915.0 2B
915.3 2C
FREQ. CODE
915.6 2D
915.9 2E
916.2 2F
916.5 30
916.8 31
917.1 32
917.4 33
917.7 34
918.0 35
918.3 36
918.6 37
918.9 38
919.2 39
919.5 3A
919.8 3B
920.1 3C
920.4 3D
920.7 3E
921.0 3F
921.3 40
921.6 41
as well as programming of application information. This
is recommended for larger installations that must maintain
systems with a variety of configurations.
A stand alone programmer, RAC16, is available for most
applications. It provides a convenient method for changing
the identity code and making basic application changes
to the transmitters and receivers.
Programming Levels
Most programming changes involve only the assignment
of the identity code. The identity code in a six digit
alphanumeric number that contains the operating
frequency and address of the unit. This level of
programming is described in this manual.
Higher levels of programming, those that allow changing
of time constants, relay assignments and decoding logic
are covered in a separate manual.
Identity Code
The unit identity code consists of a six digit alphanumeric
number such as 2E005B. The range of numbers is 0
through 9 and A through F.
The first two numbers designate one of the 81 frequencies
that are used for these systems. In a plant with many
units located in a close area, each system can be assigned
a different frequency. For reference, table 4.1 lists the
frequency for each code.
The last four numbers designate one of the 65,536 possible
address codes. Again, the range of numbers is 0 through
9 and A through F.
Each system in a plant must have a separate identity
code. Two systems with the same identity code will be
able to "talk" to each other. All systems are shipped
from the factory with a unique identity code. It is highly
recommended that the receiver identity code not be
changed, rather a transmitter identity code be made to
match that of a receiver.
Programming
The transmitter and receiver are programmed using the
same method.
Transmitters have a four position connector with one pin
removed for keying. Receivers may have a four position
or a six position connector with one pin removed for
keying. The programmer has a six position connector
with one position blanked.
Locate the programming connector on the transmitter
board or the RF/Decoder board in the receiver and
connect the plug from the programmer. Note that the
plug is polarized and must be connected with the plug
aligned with the position of the blank pin.
6 pos connector 4 pos connector
If programming a transmitter, make sure the batteries are
installed. If programming a receiver, make sure power is
applied to the RF/Decoder board (power LED is ON).
Note that an RF/Decoder board with the six position
programming connector can be powered from the
programming box and does not need external power.
If the programmer is not already on, turn the programmer
power on by pressing the ON button. The display will
show what the programmer is connected to for 5 seconds
and then will read and display the ID CODE of the unit.
SECTION 4: MAINTENANCE
4.2
ID CODE 28008C
TX CONNECTED
Enter a new six digit unit identity number using the keypad
on the programming unit. Verify the number on the LCD
display. Press the PRG push-button on the programming
unit.
For additional programming instructions refer to the
manual supplied with the programmer.
4.4 PARTS LISTS
Accessories available for the remote control system
include:
Item Part Number
Antenna mounting kit (9 Ft.) 600038-1
Antenna mounting kit (18 Ft.) 600038-2
Programmer (Stand Alone) RAC16
Programmer (PC Based) RAC17
Tables 5.1 and 6.1 list the spare parts available from
Remtron for field repair of the transmitter and receiver.
Detailed parts lists and schematics are available to support
depot level maintenance activities.
4.5 ORDERING & REPAIRS
Ordering
When ordering a Remtron product use the appropriate
Remtron part number or model number, ID Code and
any other applicable information.
Orders for standard Remtron products may be placed
with an authorized representative, distributor or direct
with the factory.
Orders for special products or modified standard products
may also be placed with an authorized representative,
however, close coordination with the factory is
recommended.
SECTION 4: MAINTENANCE
4.3
Repairs
All products in need of repair should be sent directly to
the factory at the address listed below. We recommend
calling the factory for a Return Material Authorization
(RMA) number prior to sending in the equipment. A
note should be included describing the nature of the
problem and the conditions under which the problem
occurred. Also included with the returned product, should
be the name, address and phone number where the
product is to be returned and the name and phone number
of a person familiar with the problem, who we may
contact should the need arise. Products should be returned
to:
Remtron, Inc.
1916 W. Mission Rd.
Escondido, CA 92029
PH 760-737-7800
4.6 Warranty
Remtron, Inc. warrants its material handling products to
be free from defects in material and workmanship for a
period of two (2) years from the date of the original
invoice. This warranty is void if the product was used in
other than its normal and customary manner or subjected
to misuse, neglect, accident, physical damage or was
altered or tampered with by unauthorized personnel.
Remtron further warrants its Command Pro "hand-held"
Radio Remote Control products against malfunction or
breakage, excepting total destruction of the internal circuit
board, for a period of two (2) years and thirty (30) days
from the date of the original invoice.
In event of a defect or failure to perform as specified,
Remtron will, at its discretion, repair or replace the
product. This warranty does not cover the cost of shipping
and handling of the product from the customers' location
to the factory.
This warranty gives you specific legal rights and you may
also have other rights which vary from state to state.