Centrak IT105 Clear Repeater IT-105 User Manual Installation

Centrak, Inc. Clear Repeater IT-105 Installation

Contents

Installation User Manual

Download: Centrak IT105 Clear Repeater IT-105 User Manual Installation
Mirror Download [FCC.gov]Centrak IT105 Clear Repeater IT-105 User Manual Installation
Document ID4096238
Application ID0P5AA8GNEbJMHerQp3iu9w==
Document DescriptionInstallation User Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize51.36kB (642002 bits)
Date Submitted2018-12-05 00:00:00
Date Available2018-12-05 00:00:00
Creation Date2018-12-03 22:37:14
Producing SoftwareMicrosoft® Word 2013
Document Lastmod2018-12-03 22:37:14
Document TitleCenTrak Announces Significant Growth in Healthcare Tracking Deployments
Document CreatorMicrosoft® Word 2013
Document Author: Deric Blattenberger

Installing the Clear Repeater – IT-105
Overview
Clear Repeaters, CenTrak Part number IT-105, extend the Clear Network throughout a campus. The
Clear Repeater will retransmit any valid CenTrak transmission. Installation of Clear Repeaters must be
within the Clear Network as to not leave holes or gaps in coverage and is exclusive to the CenTrak Clear
Network System.
Locations for Clear Repeaters are determined during the initial survey of a building. Locations for Clear
Repeaters are included on the CenTrak-supplied design documents. In most cases, Clear Repeaters are
installed in corridors or closets that do not contain machinery or high voltage transformers.
CAUTION!
Do not perform any wiring or connection work while the circuit is live.
The Clear Repeater must be installed such that the minimum distance between any portion of the antenna and
nearby persons is 20cm.
Installing the Clear Repeater Below the Grid
Follow this procedure to install a Clear Repeater below the grid.
1. Attach a Star Ceiling mounting attachment to the drop-ceiling track at the designated location.
For information on how to attach a Star Ceiling mounting attachment, see Installing the Star
Ceiling Attachment.
826 Newtown-Yardley Road Newtown, PA 18940  Phone 215.860.2928  Fax 215.359.0659  www.centrak.com
© CenTrak 2016. All Rights Reserved • CenTrak is a trademark of CenTrak, Inc. Proprietary and Confidential Information
2. Connect the Clear Repeater to the included Transformer power supply. Do not plug in the
transformer to a power source.
3. Remove the cover of the Clear Repeater.
4. Remove the cover of the Clear Repeater by following Steps A through C.
5. Life the Clear Repeater up to the Star Ceiling Attachment and align the slots, as seen in D and E.
6. Place the cover on the Clear Repeater as seen in figure F, and reinstall the Screw.
7. Unfold the antennas on the Clear Repeater to a 90° angle, as shown in Figure G.
8. Plug in the Transformer to complete the installation.
Installing the Clear Repeater Above the Grid
Follow this procedure to install a Clear Repeater above the grid. Refer to the following graphic for an
illustration of relevant features.
1 Attach the T-Bar bracket to the Clear Repeater as shown in the preceding illustration.
2 Lift a ceiling tile to expose the ceiling grid.
3 Attach the Clear Repeater to the included Transformer power supply.
4 Slide the clip of the T-Bar bracket over the T-Bar.
5 Unfold the antennas on the Clear Repeater to a 45° angle.
6 Replace the ceiling tile.
Installing the Star Ceiling Attachment
Follow this procedure to install the Star Ceiling Attachment on the drop-ceiling grid. CenTrak supplies
four different Star Ceiling Attachments. Use the following table to select the appropriate Star Ceiling
Attachment. The Star Ceiling Attachments are listed in order of grid width.
Part Number
ITA-633
ITA-361
ITA-353
ITA-362
Ceiling Grid Width
5/16 Inch
9/16 Inch
15/16 Inch
15/16 Inch
Panel Type
Recessed
Recessed
Flush
Recessed
826 Newtown-Yardley Road Newtown, PA 18940  Phone 215.860.2928  Fax 215.359.0659  www.centrak.com
© CenTrak 2016. All Rights Reserved • CenTrak is a trademark of CenTrak, Inc. Proprietary and Confidential Information
1. Separate the two parts of the Star Ceiling Attachment.
2. Lift up the ceiling panel and insert one half of the plastic Star Ceiling Attachment on the ceiling
track.
3. Lift up the ceiling panel on the other side of the Grid and insert the other half of the Plastic Star
Ceiling Attachment on the ceiling track.
4. Snap the two halves on the plastic Star Ceiling Attachment together. This requires lifting the
ceiling panels up slightly to slide the halves of the Star Ceiling Attachment into place.
826 Newtown-Yardley Road Newtown, PA 18940  Phone 215.860.2928  Fax 215.359.0659  www.centrak.com
© CenTrak 2016. All Rights Reserved • CenTrak is a trademark of CenTrak, Inc. Proprietary and Confidential Information

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 3
Language                        : en-US
Tagged PDF                      : Yes
Title                           : CenTrak Announces Significant Growth in Healthcare Tracking Deployments
Author                          : Deric Blattenberger
Creator                         : Microsoft® Word 2013
Create Date                     : 2018:12:03 22:37:14-05:00
Modify Date                     : 2018:12:03 22:37:14-05:00
Producer                        : Microsoft® Word 2013
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ST2-IT105

Navigation menu