Centrak IT373LTX Hand Sanitizer i-DIM-GO LTX IT-373LTX User Manual
Centrak, Inc. Hand Sanitizer i-DIM-GO LTX IT-373LTX Users Manual
Centrak >
Users Manual
IT-373LTX i-DIM-GO LTX • • • • • IT-373GJ i-DIM-GO Automatically tracks hand hygiene compliance at the caregiver level Collects data on all events at hand washing stations Designed to integrate with GOJO hand hygiene dispensers Multiple mechanisms to activate the dispenser including proximity and motion sensor Works in conjunction with CenTrak’s full RTLS and with CenTrak’s Clinical-Grade Locating Staff Badge. The Integrated Dispenser Interface Module for GOJO (i-DIM-GO) is a component of CenTrak’s Clinical-Grade Hand Hygiene Compliance Solution – the healthcare industry’s only solution designed to automatically monitor hygiene dispenser usage by caregivers as well as their entry and exit to patient care areas. It eliminates costly manual monitoring, and proactively alerts caregivers who enter patient care environments without proper hand hygiene, to assist in compliance and behavior modification. IT-373LTX units integrate with GOJO dispensers, and automatically communicate a specific caregiver’s badge ID from patient care areas along with hand hygiene events, based upon hospital determined compliance business rules. The i-DIM-GO communicates each event to the network which records each caregiver’s compliance performance. All of the recorded data is stored on CenTrak’s local or hosted server and can be accessed by third party compliance management and reporting solutions. IT-373GJ shown integrated with a GOJO dispenser The LED indicator on the Dispenser flashes a blue confirmation light when the dispenser is activated and detects a care giver with a CenTrak badge is within range (approximately 4 feet). The i-DIM-GO captures all hand hygiene events whether or not a caregiver is in direct line of sight of the module using a combination of technologies. Unlike other hand hygiene compliance solutions, CenTrak is able to capture 100% of clinical hand washing events without errors. CenTrak, Inc. 125 Pheasant Run Newtown, PA 18940 t: 215-860-2928 e: sales@centrak.com www.centrak.com © CenTrak 2014. All Rights Reserved. Proprietary and Confidential. IT-373LTX i-DIM-GO LTX Technical Specifications Operation IT-373GJ i-DIM-GO FCC Operating Frequency Range 902-928 MHz CE Operating Frequency Range 868-870 MHz Maximum transmission power 1 mW peak Low Frequency 125 KHz Indicators LED Indicators Not on unit; Enables integrated blue confirmation LED light on GOJO Dispenser Enclosure Case width 1.5 in (38.1 mm) Case height 2.75 in (70 mm) Case depth 0.6 in (15 mm) Construction ABS Plastic Environmental IT-373GJ shown integrated with a GOJO dispenser Operating Temperature 0 C to +50 C Storage temperature -30 C to +70 C Operating Humidity 10% to 90% non-condensing Power Battery type N/A, GOJO Dispenser powered Activation Sensors Proximity and/or Motion Optional configurations Low Frequency Range Up to 4 feet Note: Must use CenTrak disinfection procedure. Other methods may void product warranty. CenTrak, Inc. 125 Pheasant Run Newtown, PA 18940 t: 215-860-2928 e: sales@centrak.com www.centrak.com This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Modifying or tampering with the transceiver’s or receiver’s internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to use these products. This product or its systems are covered by one or more of the following U.S. patents: 5,917,425, 7,061,428, 7,378,964, 7,619,532. L ‘ utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. © CenTrak 2014. All Rights Reserved. Proprietary and Confidential. IC Statement: Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2014:06:06 09:25:04-04:00 Modify Date : 2014:06:06 12:26:20-04:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2014:06:06 12:26:20-04:00 Producer : PDF-XChange 4.0.163.0 [ABBYY] (Windows Seven Ultimate x64 Service Pack 1 (Build 7601)) Format : application/pdf Document ID : uuid:c6c868cc-4309-4277-ae59-25e0e65ca8a8 Instance ID : uuid:b9d31c01-1944-49bf-ba7f-e3f3ad435c36 Page Count : 3EXIF Metadata provided by EXIF.tools