Centrak IT725 Single-Use Patient Tag IT-725/IT-725P/IT-725S User Manual

Centrak, Inc. Single-Use Patient Tag IT-725/IT-725P/IT-725S Users Manual

Users Manual

Download: Centrak IT725 Single-Use Patient Tag IT-725/IT-725P/IT-725S User Manual
Mirror Download [FCC.gov]Centrak IT725 Single-Use Patient Tag IT-725/IT-725P/IT-725S User Manual
Document ID2288048
Application IDRlLe5DbtZUbdUVMFYMLs/Q==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize31.21kB (390092 bits)
Date Submitted2014-06-06 00:00:00
Date Available2014-06-06 00:00:00
Creation Date2014-06-06 09:25:04
Producing SoftwarePDF-XChange 4.0.163.0 [ABBYY] (Windows Seven Ultimate x64 Service Pack 1 (Build 7601))
Document Lastmod2014-06-06 09:27:46
Document TitleUsers Manual

IT-725 Single-Use Patient Tag
•
•
•
•
•
IT-725 Single-Use Patient Tag
Practical patient tracking solution with low cost, fully
waterproof tags which may either be discarded or recycled
Gen2IR™ Technology for Clinical-Grade Locating™ applications
Thin, small size, lightweight
Designed to integrate with existing hospital ID bracelets
Operates for 30 days – perfect more most patient flow
applications
Healthcare facilities have a critical need for the wireless monitoring of
patients to ensure safety and improve workflow. CenTrak’s Clinical-Grade
Locating™ technology was developed to meet these needs when used with
automated workflow and bed management applications. The CenTrak Tag is
securely associated with a patient wearing the tag to help with identification
before medication is administered or a medical procedure is performed, to
confirm identity and reduce errors. The tags enable patients to have
increased mobility while improving their safety by quickly alerting staff if
patients enter or leave restricted areas. Patients enjoy having the freedom
and flexibility to move as supported by their care plan.
The IT-725 tag utilizes CenTrak’s Gen2IR™ to support Clinical-Grade
Locating™ applications. Gen2IR™ enables certainty-based accuracy at the
bed-, bay- and chair-level. This empowers hospitals and healthcare
administrators to make decisions based on facts about where and when
their people and resources are located. The IT-725 tag provides the ability to
monitor patients at any time anywhere in a facility. This single tag can be
used to track, locate, protect and identify a patient in seconds.
IT-725 in use
CenTrak, Inc.
125 Pheasant Run
Newtown, PA 18940
t: 215-860-2928 e: sales@centrak.com
www.centrak.com
© CenTrak 2014. All Rights Reserved. Proprietary and Confidential.
Tags may be worn on standard issued medical ID bracelets. With a modular
design and low price, tags provide an economical solution to a wide variety
of patient management challenges.
IT-725, IT-725P,IT725S Single-Use Patient Tag
Technical Specifications
Operation
IT-725 Single-Use Patient Tag
FCC Operating Frequency Range
902-928 MHz (Model #IT-725)
CE Operating Frequency Range
868-870 MHz (Model #ITEU-725)
Group code & tag ID codes
8M code5
Outdoor transmission range
> 300 feet
Average transmission power
2 uW (average)
Gen2IR sensor
YES
Motion Sensor
YES
Tag Dimensions
Case width
1.5 in (38.1 mm)
Case height
1.98 in (50.3 mm)
Case width
0.6 in (15 mm)
Case weight (with battery)
0.77 oz (21.8 g)
Construction
Soft PVC
Environmental/Cleaning
IT-725 in use
CenTrak, Inc.
125 Pheasant Run
Newtown, PA 18940
t: 215-860-2928 e: sales@centrak.com
www.centrak.com
Operating Temperature
0 C to +70 C
Storage temperature
-25 C to +80 C
Sealing
Splash & Water resistant
Power
Battery type
Lithium CR2032
Smart tag feature
Low battery indication
This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful
interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Modifying or tampering
with the transceiver’s or receiver’s internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to use these
products. This product or its systems are covered by one or more of the following U.S. patents: 5,917,425, 7,061,428, 7,378,964, 7,619,532.
L ‘ utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit
étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif.
© CenTrak 2014. All Rights Reserved. Proprietary and Confidential.
IC Statement:
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2014:06:06 09:25:04-04:00
Modify Date                     : 2014:06:06 09:27:46-04:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2014:06:06 09:27:46-04:00
Producer                        : PDF-XChange 4.0.163.0 [ABBYY] (Windows Seven Ultimate x64 Service Pack 1 (Build 7601))
Format                          : application/pdf
Document ID                     : uuid:1433dec5-9ea1-4665-8287-a40165603874
Instance ID                     : uuid:b0f693f5-db13-4530-9600-a4166169d675
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ST2-IT725

Navigation menu