Chaney Instrument 00634TX Weather Station transmitter User Manual 00634 INST09 WA
Chaney Instrument Co. Weather Station transmitter 00634 INST09 WA
manual
INST - 00634 081309 To receive product information, register your product online. It’s quick and easy! Wireless Weather Station Log on to http://www.chaneyinstrument.com/product_reg.htm model #00634 Instruction Manual LIMITED ONE YEAR WARRANTY Chaney Instrument Company warrants that all products it manufactures to be of good material and workmanship and to be free of defects if properly installed and operated for a period of one year from date of purchase. REMEDY FOR BREACH OF THIS WARRANTY IS EXPRESSLY LIMITED TO REPAIR OR REPLACEMENT OF DEFECTIVE ITEMS. Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. In all cases, transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which shall have received normal wear and tear, been damaged, tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney. THE ABOVE-DESCRIBED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND ALL OTHER WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. CHANEY EXPRESSLY DISCLAIMS ALL LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES, WHETHER ARISING IN TORT OR BY CONTRACT FROM ANY BREACH OF THIS WARRANTY. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. CHANEY FURTHER DISCLAIMS ALL LIABILITY FROM PERSONAL INJURY RELATING TO ITS PRODUCTS TO THE EXTENT PERMITTED BY LAW. BY ACCEPTANCE OF ANY OF CHANEY’S EQUIPMENT OR PRODUCTS, THE PURCHASER ASSUMES ALL LIABILITY FOR THE CONSEQUENCES ARISING FROM THEIR USE OR MISUSE. NO PERSON, FIRM OR CORPORATION IS AUTHORIZED TO ASSUME FOR CHANEY ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS. FURTHERMORE, NO PERSON, FIRM OR CORPORATION IS AUTHORIZED TO MODIFY OR WAIVE THE TERMS OF THIS PARAGRAPH, AND THE PRECEDING PARAGRAPH, UNLESS DONE IN WRITING AND SIGNED BY A DULY AUTHORIZED AGENT OF CHANEY. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. For in-warranty repair, please contact: Customer Care Department Chaney Instrument Company 965 Wells Street Lake Geneva, WI 53147 Chaney Customer Care 877-221-1252 Mon-Fri 8:00 a.m. to 4:45 p.m. CST www.chaneyinstrument.com This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1- This device may NOT cause harmful interference, and 2- This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment. B. Wireless Sensor A. Main Unit Package Contents: (1) Main Unit (A) with stand (1) Wireless Sensor (B) with mounting bracket What You Need: • Small Phillips Screwdriver • (7) AA batteries Thank You for purchasing this ACURITE® product. Please read this manual in it’s entirety to fully enjoy the benefits and features of this product. Please keep this manual for future reference. NOTE: A clear film is applied to the LCD at the factory that must be removed prior to using this product. Locate the clear tab and simply peel to remove. Patent numbers: 5,978,738; 6,076,044; 6,597,990 -1- SEC TION 1 • OVERVIEW OF FEATURES ATOMIC CLOCK: Automatically maintains accuracy and resets for daylight saving time MAIN UNIT About the Atomic Clock ATOMIC CLOCK: Atomic clock signal reception indicator BAROMETRIC PRESSURE: Current value with trend indicator FUTURE FORECAST: Self calibrating weather forecast Moonphase WIND SPEED: Current wind speed, Peak wind speed, Average wind speed OUTDOOR CONDITIONS: Temperature & Humidity with Trend Indicators SEASONAL INFORMATION: Heat Index, Dew Point, Wind Chill (automatic) WIRELESS SENSOR: Low Battery indicator INDOOR CONDITIONS: Temperature & Humidity WIRELESS SENSOR: Wireless reception indicator HISTORY GRAPH: last 12 hours of Barometer, Outdoor Temperature, Wind Speed (user selectable) Setup and Operation Buttons A clock is considered atomic if it has an accuracy of one second in a million years. Consumer clocks are considered atomic if they attain this accuracy by receiving a signal from an atomic clock. In North America, the National Institute of Standards and Technologies operates an atomic clock in Colorado which transmits the time codes via the radio station WWVB. The Acurite clock you have purchased includes a built-in receiver which picks up the signal from the WWVB station. For the best possible reception, place the main unit with the back side facing Colorado. NOTE: Due to solar radiation in the atmosphere, the atomic clock signal is weaker during the day. Most synchronization with the WWVB atomic clock signal happens at night when there is less interference. About the Wireless Sensor This wireless weather station features a wireless sensor that provides wind, temperature and humidity data and broadcasts this information to the main display unit. This wireless sensor will provide accurate outdoor weather conditions when placed properly. The wireless sensor contains sensitive electronic components and a balanced anemometer (for wind speed measurement). Care must be taken during setup and when considering placement to make certain the unit is not dropped or struck with any falling debris from trees or structures. Tabletop Placement Display Stand SEC TION 2 • SETUP WIRELESS SENSOR A/B/C Wireless Selection ANEMOMETER: Provides wind speed, wind speed peak and wind speed average SOLAR-WEATHER SHIELD: Provides some protection from solar radiation affecting temperature readings and prevents precipitation from entering into the instrumentation pod. BATTERY COMPARTMENT INSTRUMENTATION POD: Houses the sensitive instrumentation and the wireless 433 MHz transmitter that provides weather information to the main display unit. To allow for more than one weather station and wireless sensor network to be used in close proximity, the main unit and the wireless sensor have a small switch labeled “A B C” within the battery compartments. This switch selects one of 3 wireless modes to use, and both switches MUST be set in matching positions (either A, B, or C) for wireless communication to take place successfully. Battery Choice & Temperature Range Extended periods of cold temperatures ( below -4ºF / -20ºC ) can cause alkaline batteries to function improperly. This will cause the outdoor wireless sensor to stop transmitting temperature readings. Use lithium batteries in these low temperature conditions to ensure continued operation for wireless sensors placed outdoors. NOTE: Rechargeable batteries are not recommended due to higher operating voltages. MOUNTING POINT: 40 The wireless sensor can be mounted onto a pipe (pipe not included) or onto the included surface mount bracket SURFACE MOUNT BRACKET -2- -3- Install Batteries Install Batteries NOTE: Install all batteries in both units within a 6 minute period to ensure proper wireless functionality. Always install batteries into the wireless sensor FIRST. NOTE: Install all batteries in both units within a 6 minute period to ensure proper wireless functionality. Always install batteries into the wireless sensor FIRST. Wireless Sensor - 4 “AA” Batteries Required (not included) Main Unit - 3 “AA” Batteries Required (not included) GENTLY SQUEEZE OUTER CASING AND PULL INNER INSTRUMENT POD OUT REMOVE BATTERY COMPARTMENT COVER REMOVE BATTERY COMPARTMENT COVER REPLACE BATTERY COMPARTMENT COVER NOTE: A/B/C SWITCH SELECTION MUST MATCH MAIN UNIT A/B/C SELECTION SQUEEZE REMOVE BATTERY DOOR SQUEEZE PULL SET THE OUTER CASING ASIDE, TAKE CARE THAT IT IS NOT DROPPED REMOVE BATTERY DOOR INSERT 4 FRESH “AA” BATTERIES AND REPLACE BATTERY COMPARTMENT COVER. NOTE: A/B/C SWITCH SELECTION MUST MATCH WIRELESS SENSOR A/B/C SELECTION REPLACE BATTERY COMPARTMENT COVER RE-INSTALL INNER INSTRUMENT POD UNTIL TABS ALIGN AND YOU YOU HEAR A “CLICK” INSERT 3 FRESH “AA” BATTERIES PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS. INSERT -4- BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals. -5- Main Unit : Basic Setup Setup is Now Complete After installing batteries, it is recommended that you set the clock and calendar initially. After the atomic clock signal is acquired, which may take up to 24 hours, the clock accuracy and daylight saving time changes will be automatically maintained. The wireless sensor will soon send a signal to the main unit and the two units will be synchronized. It may take a few minutes for synchronization to be complete. If both or one of the units appear to be functioning improperly, refer to the troubleshooting section in this manual. To set the clock and other preferences, press AND HOLD the “SET” button for 5 seconds to enter into SET MODE. Once in set mode, the preference you are currently setting will blink on the display. SEC TION 3 • OPERATION To adjust the currently selected (flashing) preference item, press the “+” button (press and HOLD to fast adjust). To save your adjustments, press the “SET” button again to move on to adjusting the next preference. The preference set order is as follows: 14 Day Learning Mode This weather station has a patented “fourteen day learning mode” calibration process. During this learning mode the weather station will make altitude calculations that may affect the accuracy of the forecast. Once the 14 day learning mode process is complete, the learning mode icon will disappear and the weather forecast should be ready for superior operation. TIME ZONE (PST MST CST EST) DST (Daylight Saving Time ON OR OFF) CLOCK HOUR CLOCK MINUTE YEAR CALENDAR MONTH CALENDAR YEAR You will automatically exit SET MODE if no buttons are depressed for 30 seconds. You may enter basic setup mode again at any time by pressing AND HOLDING the “SET” button. Main Unit : Scale Selection The main unit is capable of displaying some values in an alternate scale mode. To switch between modes, press the “SCALE” button. SCALE MODE 1 - U.S. Standard Temperature - ºF (fahrenheit) Barometric Pressure- inHg (inches of mercury) Wind Speed/Peak/Average- mph (miles per hour) SCALE MODE 2 - Imperial Standard Temperature - ºC (Celsius) Barometric Pressure- hPa (Hectopascal) Wind Speed/Peak/Average- kph (kilometers per hour) NOTE: The “WIND SPEED” history mode chart will not change to “kph” scale, it will remain displaying “mph” data. -6- Future Forecast Icon The future forecast feature automatically gives you the predicted weather forecast icon for the next 12 to 24 hours based on an advanced algorithm that analyzes barometric pressure changes and temperature. This weather forecaster will provide the most accurate forecast that a single station instrument can provide. rain or snow rain or snow HEAVY STORM STORMY MOSTLY CLOUDY PARTLY CLOUDY MOSTLY SUNNY heavy stormy weather conditions are forecasted when flashing stormy conditions are forecasted next 12-24 hours mostly cloudy conditions are forecasted next 12-24 hours partly cloudy conditions are forecasted next 12-24 hours mostly sunny conditions are forecasted next 12-24 hours -7- SEC TION 3 • OPERATION SEC TION 3 • OPERATION Wind Speed Data Window WIND SPEED: most current wind speed reading, this value is updated every 18 seconds. The main unit has a signal reception icon near the atomic clock display. If the atomic clock signal bars are low, the clock may be inaccurate or may not automatically adjust for daylight saving time (DST). Refer to the troubleshooting section in this manual if you are having reception issues. PEAK: the highest wind speed reading recorded in the last hour. AVERAGE: the combined averaged wind speed readings from the last 2 minutes. NOTE: The wireless sensor must be placed outdoors to observe outdoor wind speed. Wireless Signal Reception Icons The main unit has a signal reception icon in the outdoor wind speed/ temperature display area. If most or all four of the bars are present, wireless reception is good and no action is required. If there are a low number of “bars” present, you may experience wind speed/temperature inaccuracy. In either case, you may need to relocate the main unit or the wireless sensor. This weather station features an advanced wind speed data window that provides the wind speed, the peak value and the average value. Moonphase This weather station features a moonphase window which will automatically display the current moonphase, provided the calendar is set properly. NEW Seasonal Window (wind chill/dew point/heat index) WAXING CRESCENT 1ST QUARTER WAXING GIBBOUS FULL WANING GIBBOUS 3RD QUARTER WANING CRESCENT This weather station features a “Seasonal” window which will automatically display the wind chill, the dew point or the heat index information when it is relevant. Main Unit : MIN/MAX Memory less than 40ºF (4ºC) WIND CHILL between 41ºF - 79ºF (5ºC - 26ºC) DEW POINT above 80ºF (27ºC) HEAT INDEX History Mode Graphing This weather station features a selectable history mode which will graph and display the changes for the last 12 hours (-12,-6,-3,-2,-1, 0). There are 3 selectable weather categories; Barometer (barometric pressure), Temperature or Wind Speed. Press the “HISTORY MODE” button to alternate through the 3 options. Note the graphing icon “ “ next to the currently selected data window. BAROMETER: hourly reading on the hour. TEMPERATURE: hourly (outdoor) temperature reading on the hour. WIND SPEED: hourly wind speed AVERAGE reading. -8- This wireless weather station features a MIN/MAX memory feature which records the MINIMUM and MAXIMUM indoor & outdoor temperature and humidity readings. To view the MINIMUM temperature and humidity readings, press and release the “MIN/MAX” button. Note the “MIN” icon on the display. To clear the MIN recorded values, press and hold the “+” and “SCALE” buttons simultaneously for 3 seconds while in the MIN view mode. Dashes will display in the display to confirm you have cleared the MIN values for outdoor temperature and indoor temperature/humidity. To view the MAXIMUM temperature and humidity readings, press and release the “MIN/MAX” button. Note the “MAX” icon on the display. To clear the MAX recorded values, press and hold the “+” and “SCALE” buttons simultaneously for 3 seconds while in the MAX view mode. Dashes will display in the display to confirm you have cleared the MAX values for outdoor temperature and indoor temperature/humidity. -9- Placement of Sensor SEC TION 4 • PLACEMENT TV MOUNT IN AN OPEN AREA FOR UN-OBSTRUCTED WIND SPEED MEASUREMENT (.91 m) (30 meters) The wireless sensor MUST BE MOUNTED OUTDOORS to observe outdoor temperature/humidity/wind speed and relay the information to the main unit display. The wireless sensor must be placed less than 100 feet (30 m) from the main unit. The wireless sensor must be mounted securely. It is advised that the wireless sensor be mounted well above and away from all obstructions to report the wind speed accurately. There are three main mounting options to consider: “FENCEPOST” OR SIMILAR MOUNTING “RAILING” OR SIMILAR MOUNTING Now that setup is complete and you understand how to operate the weather station, you must choose a location to place the wireless sensor and the main unit. The wireless sensor MUST be placed less than 100 feet (30 meters) away from the main unit. TIGHTEN CLAMP SCREWS! This wireless weather station uses radio frequency for communication, which is susceptible to interference from other electronic devices and large metallic items or thick walls. Always place both units at least 3 feet (.91 m) away from appliances ( TV, microwave, radios, etc. ) or objects that may interfere with the wireless communication ( large metal surfaces, thick stone walls, etc. ). INCLUDED MOUNTING BRACKET Placement of Main Unit There are 2 placement options for the main unit. You may hang the main unit on a wall using the integrated hang hole. Alternatively, you may place the main unit on a table top or other flat surface using the included detachable table top display stand. - 10 - INCLUDED MOUNTING BRACKET “POLE” OR SIMILAR MOUNTING TIGHTEN CLAMP SCREWS! Place the main unit in a dry area free of dirt and dust. To help ensure an accurate indoor temperature measurement, be sure to place the main unit out of direct sunlight, and away from any heat sources or vents in your home. For the best atomic clock signal reception, place the main unit with the back side facing the state of Colorado. SCREWS SCREWS Please USE EXTREME CARE when handling the wireless sensor and the main unit. The wireless sensor contains sensitive electronic components and a balanced anemometer (for wind speed measurement). Care must be taken during setup and when considering placement to make certain the unit is not dropped or struck with any falling debris from trees or structures. USE CAUTION when utilizing tools or equipment for mounting the wireless sensor. Enlist the help of another individual when necessary. TIGHTEN CLAMP SCREWS! INCLUDED MOUNTING BRACKET NOT USED (POLE NOT INCLUDED) Mount the sensor onto a 3/4” schedule 40 (25.8 mm O.D.) pipe (not included). PVC plastic pipe is recommended over a metallic pipe due to lower risk of lightening strikes. Insert the pole completely into the bottom of the wireless sensor. Tighten the “CLAMP” screws securely to make certain the wireless sensor will not fall or slide off of the pole in high winds. Use caution when installing sensor or erecting the pole. Do not install during electrical storms. Do not place pole or sensor near electrical transmission lines or electrical equipment. - 11 - Troubleshooting SEC TION 5 • PRODUC T SPECIFICATIONS Measurement Ranges Problem Temperature Main Unit: 32ºF to 122ºF / 0ºC to 50ºC Wireless Sensor: -40ºF to 158ºF / -40ºC to 70ºC Possible Solution Relocate the main unit and/or the wireless sensor. Both units must be within 100 feet (30 m) from each other. Make sure both units are placed at least 3 feet (.91 m) from other electronic appliances and devices that may interfere with the wireless communication (such as TV’s, microwaves, computers etc). NOTE: It may take up to 20 minutes for the main unit to re-synchronize with the sensor when batteries are replaced. Use lithium batteries in sensor when temperature is below -4ºF (-20ºC). Bad Wireless Sensor Reception Humidity Main Unit: 16% to 98% Relative Humidity Wireless Sensor: 1% to 99% Relative Humidity no bars Wind Speed Wireless Sensor: 0 to 100 m.p.h. / 0 to 161 kph Specifications Power Requirements Main Unit: 3 x “AA” alkaline or lithium batteries Wireless Sensor: 4 x “AA” alkaline or lithium batteries Atomic Clock Frequency: WWVB 60Khz Synchronizes Daily Wireless Communication 433 MHz Radio Frequency-Transmission every 18 seconds Set Wireless ID Rotate the wireless sensor 90º on its mounting point. Make certain there are no large stone or metallic surfaces disrupting the signal line-ofsight to the state of Colorado. Make sure the main unit and wireless sensor are placed at least 3 feet (.91 m) from other electronic appliances and devices that may interfere with the wireless communication (such as TV’s, microwaves, computers etc). Large metallic surfaces will interfere with the atomic clock signal. Bad Atomic Clock Reception no bars This wireless thermometer uses long range 433mhz radio frequency for communication. No Wireless Sensor Data (no communication) In the event that you have reception problems due to interference, both the main unit and the wireless sensor have a selectable wireless ID. The ID switches are located within the battery compartments of the main unit and the wireless sensor. no bars and flashing antenna icon Main Unit Display Not Working You may choose A, B or C; but both the main unit and the wireless sensor ID's must match for successful synchronization. Make certain that the batteries are installed correctly and that they are contacting the terminals. Make certain all contacts are clean. The batteries may need replacing. ABC Both wireless ID’s must match - 12 - If wireless reception is bad (no bars), see “Bad Reception” section above. The wireless ID setting on each unit must match for all units to communicate properly. See “Set Wireless ID” on the previous page. Please DO NOT return product to the retail store. For technical assistance and product return information, please call Customer Care: 877-221-1252 Mon. - Fri. 8:00 A.M. to 4:45 P.M. (CST) www.chaneyinstrument.com - 13 -
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 Modify Date : 2009:08:19 17:20:26+08:00 Create Date : 2009:08:19 17:20:26+08:00 Metadata Date : 2009:08:19 17:20:26+08:00 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : 00634 INST09 WA.pdf Creator : HP_Owner Document ID : uuid:0b6a8da9-05be-4984-a650-72b33a52c8bc Instance ID : uuid:98bbe172-f30e-4441-afc4-2511ad79db12 Producer : Acrobat Distiller 7.0.5 (Windows) Page Count : 7 Author : HP_OwnerEXIF Metadata provided by EXIF.tools