Chaney Instrument 275TX Weather Station User Manual INST15 00275RM

Chaney Instrument Co. Weather Station INST15 00275RM

User Manual

Instruction ManualSAVE THIS MANUAL FOR FUTURE REFERENCE.Questions? Contact Customer Support at (877) 221-1252 or visit www.AcuRite.com.CONTENTSPackage Contents .................. 2Product Registration ............... 2?eatures  ;eneÛts ................. 3Setup .................................... 4Placement Guidelines ............. 5Using the Monitor .................. 6Add-on Wired Sensors ........... 7Troubleshooting ..................... 7SpeciÛcations ......................... 8FCC Information .................... 8Customer Support .................. 9Warranty............................... 9Temperature & Humidity Monitor00275RM00275TX
2 3Features & :eneÚtsCongratulations on your new AcuRite product. To ensure the best  possible product performance, please read this manual in its entirety  and retain it for future reference. Package Contents1. Outdoor Monitor2. Mounting hardware3. Instruction manualPRODUCT REGISTRATIONRegister online  to receive 1 year  warranty protectionwww.AcuRite.comIMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICEŹRegister a Product7 621345494FRONT1.  Wireless Signal Indicator Flashes when data is being wirelessly transmitted.BACK2. Sensor Input Plug-in for additional sensors (sold separately).3. Integrated Keyhole For easy wall mounting. 4.  Wired Sensor Retention Slot Simplifies cord management when using add-on wired sensors (sold separately).5. Monitor ID Alphanumeric ID used to identify the Monitor during system configuration.6. Reset Button Resets sensor transmission.7. Battery Compartment8.  Battery Compartment Cover 9. Mounting Hardware Includes drywall anchor  and screw. Item     Qty   Diameter    Length Screw    1       #6          3/4” Anchor  1       #6          3/4”8
4 5PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in Úre$ as batteries may explode or leac. DO NOT mix old and new batteries or types of batteries (alcaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.SETUP1 2Install or Replace BatteriesBatteries MUST be installed for this product to operate. AcuRite recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.1.  Twist off the battery compartment cover. 2.  Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.3.  Replace the battery cover.Write Down the Monitors IDRecord the unique 6-digit alphanumeric ID, located on the back of the Monitor. This unique ID may be referenced for connectivity functions. ID:  Monitor Setup Placement for Maximum Accuracy AcuRite products are sensitive to surrounding environmental conditions. Proper placement of the Monitor is critical to the accuracy and performance of the product. Monitor PlacementThe Monitor is designed for indoor or outdoor use. The Monitor stands upright for tabletop use or is wall-mountable. Place the Monitor outside to observe outdoor conditions. The Monitor is water-resistant and designed for general outdoor use. However, to extend its life, place the Monitor in an area protected from direct weather elements.Hang the Monitor using the integrated keyhole, or by using string (not included) to hang it from a suitable location, like a well-covered tree branch. The best location is 4 to 8 feet (1.2 - 2.4 meters) above ground with permanent shade and plenty of fresh air to circulate around the Monitor.Important Placement Guidelines• Monitor must be within 330 feet (100 m) of companion unit (sold separately). MAXIMIZE WIRELESS RANGEPlace units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.PREVENT WIRELESS INTERFERENCEPlace both units at least 3 feet (90 cm) away from electronic devices (TV, computer, microwave, radio, etc.).LOCATE AWAY FROM HEAT SOURCESTo ensure accurate temperature measurement, place Monitor out of direct sunlight and away from any heat sources.LOCATE AWAY FROM HUMIDITY SOURCESTo ensure accurate humidity measurement, locate Monitor away from humidity sources. Avoid installing the Monitor near indoor pools, spas, or other bodies of water. Water sources may impact humidity accuracy.LOCATE AWAY FROM SPRINKLER HEADSDO NOT install the sensor where it will be sprayed by a sprinkler system. This may force water inside the sensor.1Install Batteries 2 AA Batteries2Write Down Monitors ID  6 digit alphanumeric IDThe Monitor requires lithium batteries in low temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the Monitor for temperatures below -4°F / -20°C.
6 7OPERATIONUsing the MonitorThe Monitor features built-in temperature and humidity sensors, to view current conditions in the location where the Monitor is placed.Expand the SystemThe Monitor can be expanded to track additional conditions using compatible wired sensors (optional; sold separately) that simply plug into the Monitor. Wired sensors feature an extra-long cord, perfect for installing the sensors in hard-to-reach places. Compatible digital displays, wired sensors and companion units are available at: www.AcuRite.comTroubleshootingProblem Possible SolutionInaccuratetemperature or  humidity•  Verify the Monitor is placed away from any heat sources or vents (see page 5).•  Verify the Monitor is positioned away from moisture sources (see page 5). If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call  (877) 221-1252 for assistance.Basic Setup is CompleteThe Monitor is now ready for use, and may be synchronized with a companion unit.TV 3(90 cm)ATLEASTAPARTFor more information, visit our Knowledge Base at http://www.AcuRite.com/kbaseAdd-on Wired SensorsAdd-On Sensor Perfect for:Water Detector with audible alertModel 06010RM• Basement Üooding• Roof leaks• Leaky appliances• Sump pump failure• Tracking high or low water level• Pool, spa, pond or fountain temperature• Preventing frozen pipes• Seeding, potting and gardeningSpot Check Temperature & Humidity SensorModel 06012RM• Monitoring conditions in hard to reach places (attic, basement, etc.)• Pet areas• Evaluating HVAC coverage in your home• Monitoring conditions in nursery or childs roomLiquid & Soil Temperature SensorModel 06011RM
8 9FCC InformationThis device complies with part 15 of FCC rules. Operation is subject to the following two conditions:1- This device may NOT cause harmful interference, and2- This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modiÛcations to this equipment. Such modiÛcations could void the user authority to operate the equipment.Operation is subject to the following two conditions:(1) This device may not cause interference, and(2) This device must accept any interference received, including interference that may cause undesired operation of the device.Limited One Year Warranty At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. We recommend that you visit us at www.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your original proof of purchase in order to obtain warranty beneÛts.Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of Ûtness for a particular purpose. Chaney expressly disclaims all liability for special, consequential or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Chaneys products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, Ûrm or corporation is authorized to assume for Chaney any other liability in connection with the sale of its products. Furthermore, no person, Ûrm or corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty gives you speciÛc legal rights, and you may also have other rights which vary from state to state.For in-warranty claims:  Chaney Instrument Co.  965 Wells St.,  Lake Geneva, WI 53147Customer SupportAcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways: (877) 221-1252  info@chaney-inst.com24/7 support at www.AcuRite.comŹ Installation Videos  Ź Register your Product Ź Instruction Manuals  Ź Support User Forum Ź Replacement Parts  Ź Submit Feedback & IdeasPRODUCT REGISTRATIONRegister online  to receive 1 year  warranty protectionwww.AcuRite.comIMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICEŹRegister a ProductCare & MaintenanceClean with a soft, damp cloth. Do not use caustic cleaners or abrasives.SpeciÚcationsTEMPERATURE RANGE -40ºF to 158ºF; -40ºC to 70ºCHUMIDITY RANGE 1% to 99% RHWIRELESS RANGE 330ft / 100m depending on home construction materialsOPERATING FREQUENCYPOWER 2 x AA alkaline or lithium batteries433.92 MHzCet appareil est conforme aux CNR exemptes de licence d'Industrie Canada .Son fonctionnement est soumis aux deux conditions suivantes :( 1 ) Ce dispositif ne peut causer d'interférences ; et( 2 ) Ce dispositif doit accepter toute interférence , y compris les interférencesqui peuvent causer un mauvais fonctionnement de l'appareil.This device complies with Industry Canada’s licence-exempt RSSs.
©Chaney Instrument Co. All rights reserved.  AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy-rights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.Printed in China00275 INST 052215It’s More than Accurate, it’s AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to  Plan your day with conÛdence™.www.AcuRite.comWeather StationsTemperature & HumidityWeather Alert RadioKitchen Thermometers & TimersClocks

Navigation menu