Chaney Instrument 275TX Weather Station User Manual INST15 00275RM

Chaney Instrument Co. Weather Station INST15 00275RM

User Manual

Download: Chaney Instrument 275TX Weather Station User Manual INST15 00275RM
Mirror Download [FCC.gov]Chaney Instrument 275TX Weather Station User Manual INST15 00275RM
Document ID2709611
Application IDtu5BbVUsvPJl3L5+u1HQnA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize20.51kB (256322 bits)
Date Submitted2015-08-10 00:00:00
Date Available2015-08-11 00:00:00
Creation Date2015-08-06 23:03:17
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2015-08-09 22:45:29
Document TitleINST15_00275RM-请确认.pdf
Document CreatorAdobe InDesign CC 2014 (Macintosh)
Document Author: User

Instruction Manual
Temperature & Humidity Monitor
00275RM
00275TX
CONTENTS
Package Contents .................. 2
Product Registration ............... 2
?eatures  ;eneÛts ................. 3
Setup .................................... 4
Placement Guidelines ............. 5
Using the Monitor .................. 6
Add-on Wired Sensors ........... 7
Troubleshooting ..................... 7
SpeciÛcations......................... 8
FCC Information .................... 8
Customer Support .................. 9
Warranty............................... 9
Questions? Contact Customer Support at
(877) 221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Features & :eneÚts
Congratulations on your new AcuRite product. To ensure the best
possible product performance, please read this manual in its entirety
and retain it for future reference.
FRONT
1. Wireless Signal Indicator
Flashes when data is being
wirelessly transmitted.
Package Contents
1. Outdoor Monitor
2. Mounting hardware
3. Instruction manual
PRODUCT MUST BE REGISTERED
TO RECEIVE WARRANTY SERVICE
IMPORTANT
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
BACK
www.AcuRite.com
2. Sensor Input
Plug-in for additional sensors
(sold separately).
ŹRegister a Product
3. Integrated Keyhole
For easy wall mounting.
6 4
4. Wired Sensor Retention Slot
Simplifies cord management
when using add-on wired
sensors (sold separately).
5. Monitor ID
Alphanumeric ID used to
identify the Monitor during
system configuration.
6. Reset Button
Resets sensor transmission.
7.
Battery Compartment
8. Battery Compartment Cover
9. Mounting Hardware
Includes drywall anchor
and screw.
Item
Qty Diameter
Screw 1
#6
Anchor 1
#6
Length
3/4”
3/4”
SETUP
Placement for Maximum Accuracy
Monitor Setup
1 Install or Replace Batteries
2 Write Down the Monitors ID
Batteries MUST be installed for
this product to operate. AcuRite
recommends high quality alkaline
or lithium batteries for the best
product performance. Heavy duty
or rechargeable batteries are not
recommended.
Record the unique 6-digit
alphanumeric ID, located on
the back of the Monitor. This
unique ID may be referenced for
connectivity functions.
ID:
1. Twist off the battery
compartment cover.
2. Insert 2 x AA batteries into
the battery compartment, as
shown. Follow the polarity
(+/-) diagram in the battery
compartment.
AcuRite products are sensitive to surrounding environmental conditions. Proper
placement of the Monitor is critical to the accuracy and performance of the
product.
Monitor Placement
The Monitor is designed for indoor or outdoor use. The Monitor
stands upright for tabletop use or is wall-mountable.
Place the Monitor outside to observe outdoor conditions. The
Monitor is water-resistant and designed for general outdoor
use. However, to extend its life, place the Monitor in an area
protected from direct weather elements.
Hang the Monitor using the integrated keyhole, or by using string (not
included) to hang it from a suitable location, like a well-covered tree branch.
The best location is 4 to 8 feet (1.2 - 2.4 meters) above ground with permanent
shade and plenty of fresh air to circulate around the Monitor.
Important Placement Guidelines
• Monitor must be within 330 feet (100 m) of companion unit (sold separately).
3. Replace the battery cover.
MAXIMIZE WIRELESS RANGE
Install Batteries
2 AA Batteries
Place units away from large metallic items, thick walls, metal surfaces, or other
objects that may limit wireless communication.
PREVENT WIRELESS INTERFERENCE
Place both units at least 3 feet (90 cm) away from electronic devices (TV,
computer, microwave, radio, etc.).
LOCATE AWAY FROM HEAT SOURCES
Write Down Monitors ID
6 digit alphanumeric ID
The Monitor requires lithium batteries in low temperature conditions. Cold
temperatures can cause alkaline batteries to function improperly. Use lithium
batteries in the Monitor for temperatures below -4°F / -20°C.
To ensure accurate temperature measurement, place Monitor out of direct
sunlight and away from any heat sources.
LOCATE AWAY FROM HUMIDITY SOURCES
To ensure accurate humidity measurement, locate Monitor away from humidity
sources. Avoid installing the Monitor near indoor pools, spas, or other bodies
of water. Water sources may impact humidity accuracy.
LOCATE AWAY FROM SPRINKLER HEADS
DO NOT install the sensor where it will be sprayed by a sprinkler system. This
may force water inside the sensor.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE
WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to
be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of
used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries
in Úre$ as batteries may explode or leac. DO NOT mix old and new batteries or types of batteries (alcaline/standard). DO NOT use rechargeable batteries. DO NOT
recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.
Add-on Wired Sensors
Add-On Sensor
TV
Perfect for:
AT
LEAST
• Basement Üooding
• Roof leaks
• Leaky appliances
• Sump pump failure
• Tracking high or low water level
(90 cm)
APART
Water Detector
with audible alert
For more information, visit our Knowledge Base at http://www.AcuRite.com/kbase
Model 06010RM
Basic Setup is Complete
• Pool, spa, pond or fountain
temperature
• Preventing frozen pipes
The Monitor is now ready for use, and may be synchronized with a companion
unit.
Liquid & Soil Temperature Sensor
Model 06011RM
OPERATION
• Seeding, potting and gardening
• Monitoring conditions in hard to
reach places (attic, basement, etc.)
Using the Monitor
The Monitor features built-in temperature and humidity sensors, to view current
conditions in the location where the Monitor is placed.
Expand the System
Spot Check Temperature & Humidity
Sensor
Model 06012RM
The Monitor can be expanded to track additional conditions using compatible
wired sensors (optional; sold separately) that simply plug into the Monitor.
Wired sensors feature an extra-long cord, perfect for installing the sensors in
hard-to-reach places.
Compatible digital displays, wired sensors and companion units are
available at: www.AcuRite.com
• Pet areas
• Evaluating HVAC coverage in your
home
• Monitoring conditions in nursery or
childs room
Troubleshooting
Problem
Inaccurate
temperature or
humidity
Possible Solution
•
•
Verify the Monitor is placed away from any heat
sources or vents (see page 5).
Verify the Monitor is positioned away from moisture
sources (see page 5).
If your AcuRite product does not operate properly after trying
the troubleshooting steps, visit www.AcuRite.com or call
(877) 221-1252 for assistance.
Care & Maintenance
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives.
SpeciÚcations
TEMPERATURE RANGE
-40ºF to 158ºF; -40ºC to 70ºC
HUMIDITY RANGE
1% to 99% RH
WIRELESS RANGE
330ft / 100m depending on home construction materials
OPERATING FREQUENCY
433.92 MHz
POWER
2 x AA alkaline or lithium batteries
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
1- This device may NOT cause harmful interference, and
2- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modiÛcations to this equipment.
Such modiÛcations could void the user authority to operate the equipment.
This device complies with Industry Canada’s licence-exempt RSSs.
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation of the device.
Cet appareil est conforme aux CNR exemptes de licence d'Industrie Canada .
Son fonctionnement est soumis aux deux conditions suivantes :
( 1 ) Ce dispositif ne peut causer d'interférences ; et
( 2 ) Ce dispositif doit accepter toute interférence , y compris les interférences
qui peuvent causer un mauvais fonctionnement de l'appareil.
Customer Support
AcuRite customer support is committed to providing you with best-inclass service. For assistance, please have the model number of this
product available and contact us in any of the following ways:
(877) 221-1252
info@chaney-inst.com
24/7 support at www.AcuRite.com
Ź Installation Videos
Ź Instruction Manuals
Ź Replacement Parts
Ź Register your Product
Ź Support User Forum
Ź Submit Feedback & Ideas
PRODUCT MUST BE REGISTERED
TO RECEIVE WARRANTY SERVICE
IMPORTANT
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
www.AcuRite.com
Limited One Year Warranty
At AcuRite, we proudly uphold our commitment
to quality technology. Chaney Instrument Co.
warrants that all products it manufactures to
be of good material and workmanship, and to
be free of defects when properly installed and
operated for a period of one year from the date
of purchase.
ŹRegister a Product
and tear, been damaged (including by acts of nature), tampered,
abused, improperly installed, damaged in shipping, or repaired
or altered by others than authorized representatives of Chaney.
The above-described warranty is expressly in lieu of all other
warranties, express or implied, and all other warranties are
hereby expressly disclaimed, including without limitation the
implied warranty of merchantability and the implied warranty
of Ûtness for a particular purpose. Chaney expressly disclaims
all liability for special, consequential or incidental damages,
whether arising in tort or by contract from any breach of this
warranty. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation
We recommend that you visit us at www.AcuRite. or exclusion may not apply to you. Chaney further disclaims all
com for the fastest way to register your product. liability from personal injury relating to its products to the extent
However, product registration does not eliminate permitted by law. By acceptance of any of Chaneys products,
the purchaser assumes all liability for the consequences arising
the need to retain your original proof of
from their use or misuse. No person, Ûrm or corporation is
purchase in order to obtain warranty beneÛts.
authorized to assume for Chaney any other liability in connection
Chaney Instrument Co. warrants that all products it manufactures with the sale of its products. Furthermore, no person, Ûrm or
corporation is authorized to modify or waive the terms of this
to be of good material and workmanship, and to be free of
paragraph, and the preceding paragraph, unless done in writing
defects when properly installed and operated for a period of
and signed by a duly authorized agent of Chaney. This warranty
one year from the date of purchase. Remedy for breach of this
gives you speciÛc legal rights, and you may also have other
warranty is limited to repair or replacement of the defective
rights which vary from state to state.
item(s). Any product which, under normal use and service, is
proven to breach the warranty contained herein within ONE
For in-warranty claims: Chaney Instrument Co.
YEAR from date of sale will, upon examination by Chaney,
965 Wells St., Lake Geneva, WI 53147
and at its sole option, be repaired or replaced by Chaney.
Transportation costs and charges for returned goods shall
be paid for by the purchaser. Chaney hereby disclaims all
responsibility for such transportation costs and charges. This
warranty will not be breached, and Chaney will give no credit
for products it manufactures which have received normal wear
Weather
Stations
Temperature
& Humidity
Weather
Alert Radio
Kitchen
Thermometers
& Timers
Clocks
It’s More than Accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with conÛdence™.
www.AcuRite.com
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of
the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyPrinted in China
00275 INST 052215
rights are the property of their respective owners. AcuRite uses patented technology.
Visit www.AcuRite.com/patents for details.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : User
Create Date                     : 2015:08:06 23:03:17+08:00
Modify Date                     : 2015:08:09 22:45:29+08:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2015:08:09 22:45:29+08:00
Creator Tool                    : Adobe InDesign CC 2014 (Macintosh)
Instance ID                     : uuid:75da8566-8ad5-4747-b865-12c3effb80c9
Original Document ID            : xmp.did:2E7F6188252168118A6DE1A4B05A3BCA
Document ID                     : xmp.id:699419d9-55a6-493f-8ab7-7113498d8ae1
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:f66001c7-47ae-445f-8dc3-a56f10c67029
Derived From Document ID        : xmp.did:56f66f20-33b5-4b23-81ce-98ea34fe6e8d
Derived From Original Document ID: xmp.did:2E7F6188252168118A6DE1A4B05A3BCA
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Macintosh)
History Changed                 : /
History When                    : 2015:05:26 15:54:15-05:00
Format                          : application/pdf
Title                           : INST15_00275RM-请确认.pdf
Creator                         : User
Producer                        : Acrobat Distiller 11.0 (Windows)
Trapped                         : False
Page Count                      : 6
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RNE275TX