Chaney Instrument 275TX Weather Station User Manual INST15 00275RM
Chaney Instrument Co. Weather Station INST15 00275RM
User Manual
Instruction Manual Temperature & Humidity Monitor 00275RM 00275TX CONTENTS Package Contents .................. 2 Product Registration ............... 2 ?eatures ;eneÛts ................. 3 Setup .................................... 4 Placement Guidelines ............. 5 Using the Monitor .................. 6 Add-on Wired Sensors ........... 7 Troubleshooting ..................... 7 SpeciÛcations......................... 8 FCC Information .................... 8 Customer Support .................. 9 Warranty............................... 9 Questions? Contact Customer Support at (877) 221-1252 or visit www.AcuRite.com. SAVE THIS MANUAL FOR FUTURE REFERENCE. Features & :eneÚts Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference. FRONT 1. Wireless Signal Indicator Flashes when data is being wirelessly transmitted. Package Contents 1. Outdoor Monitor 2. Mounting hardware 3. Instruction manual PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE IMPORTANT PRODUCT REGISTRATION Register online to receive 1 year warranty protection BACK www.AcuRite.com 2. Sensor Input Plug-in for additional sensors (sold separately). ŹRegister a Product 3. Integrated Keyhole For easy wall mounting. 6 4 4. Wired Sensor Retention Slot Simplifies cord management when using add-on wired sensors (sold separately). 5. Monitor ID Alphanumeric ID used to identify the Monitor during system configuration. 6. Reset Button Resets sensor transmission. 7. Battery Compartment 8. Battery Compartment Cover 9. Mounting Hardware Includes drywall anchor and screw. Item Qty Diameter Screw 1 #6 Anchor 1 #6 Length 3/4” 3/4” SETUP Placement for Maximum Accuracy Monitor Setup 1 Install or Replace Batteries 2 Write Down the Monitors ID Batteries MUST be installed for this product to operate. AcuRite recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended. Record the unique 6-digit alphanumeric ID, located on the back of the Monitor. This unique ID may be referenced for connectivity functions. ID: 1. Twist off the battery compartment cover. 2. Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment. AcuRite products are sensitive to surrounding environmental conditions. Proper placement of the Monitor is critical to the accuracy and performance of the product. Monitor Placement The Monitor is designed for indoor or outdoor use. The Monitor stands upright for tabletop use or is wall-mountable. Place the Monitor outside to observe outdoor conditions. The Monitor is water-resistant and designed for general outdoor use. However, to extend its life, place the Monitor in an area protected from direct weather elements. Hang the Monitor using the integrated keyhole, or by using string (not included) to hang it from a suitable location, like a well-covered tree branch. The best location is 4 to 8 feet (1.2 - 2.4 meters) above ground with permanent shade and plenty of fresh air to circulate around the Monitor. Important Placement Guidelines • Monitor must be within 330 feet (100 m) of companion unit (sold separately). 3. Replace the battery cover. MAXIMIZE WIRELESS RANGE Install Batteries 2 AA Batteries Place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication. PREVENT WIRELESS INTERFERENCE Place both units at least 3 feet (90 cm) away from electronic devices (TV, computer, microwave, radio, etc.). LOCATE AWAY FROM HEAT SOURCES Write Down Monitors ID 6 digit alphanumeric ID The Monitor requires lithium batteries in low temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the Monitor for temperatures below -4°F / -20°C. To ensure accurate temperature measurement, place Monitor out of direct sunlight and away from any heat sources. LOCATE AWAY FROM HUMIDITY SOURCES To ensure accurate humidity measurement, locate Monitor away from humidity sources. Avoid installing the Monitor near indoor pools, spas, or other bodies of water. Water sources may impact humidity accuracy. LOCATE AWAY FROM SPRINKLER HEADS DO NOT install the sensor where it will be sprayed by a sprinkler system. This may force water inside the sensor. PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS. BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in Úre$ as batteries may explode or leac. DO NOT mix old and new batteries or types of batteries (alcaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals. Add-on Wired Sensors Add-On Sensor TV Perfect for: AT LEAST • Basement Üooding • Roof leaks • Leaky appliances • Sump pump failure • Tracking high or low water level (90 cm) APART Water Detector with audible alert For more information, visit our Knowledge Base at http://www.AcuRite.com/kbase Model 06010RM Basic Setup is Complete • Pool, spa, pond or fountain temperature • Preventing frozen pipes The Monitor is now ready for use, and may be synchronized with a companion unit. Liquid & Soil Temperature Sensor Model 06011RM OPERATION • Seeding, potting and gardening • Monitoring conditions in hard to reach places (attic, basement, etc.) Using the Monitor The Monitor features built-in temperature and humidity sensors, to view current conditions in the location where the Monitor is placed. Expand the System Spot Check Temperature & Humidity Sensor Model 06012RM The Monitor can be expanded to track additional conditions using compatible wired sensors (optional; sold separately) that simply plug into the Monitor. Wired sensors feature an extra-long cord, perfect for installing the sensors in hard-to-reach places. Compatible digital displays, wired sensors and companion units are available at: www.AcuRite.com • Pet areas • Evaluating HVAC coverage in your home • Monitoring conditions in nursery or childs room Troubleshooting Problem Inaccurate temperature or humidity Possible Solution • • Verify the Monitor is placed away from any heat sources or vents (see page 5). Verify the Monitor is positioned away from moisture sources (see page 5). If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call (877) 221-1252 for assistance. Care & Maintenance Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. SpeciÚcations TEMPERATURE RANGE -40ºF to 158ºF; -40ºC to 70ºC HUMIDITY RANGE 1% to 99% RH WIRELESS RANGE 330ft / 100m depending on home construction materials OPERATING FREQUENCY 433.92 MHz POWER 2 x AA alkaline or lithium batteries FCC Information This device complies with part 15 of FCC rules. Operation is subject to the following two conditions: 1- This device may NOT cause harmful interference, and 2- This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modiÛcations to this equipment. Such modiÛcations could void the user authority to operate the equipment. This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference received, including interference that may cause undesired operation of the device. Cet appareil est conforme aux CNR exemptes de licence d'Industrie Canada . Son fonctionnement est soumis aux deux conditions suivantes : ( 1 ) Ce dispositif ne peut causer d'interférences ; et ( 2 ) Ce dispositif doit accepter toute interférence , y compris les interférences qui peuvent causer un mauvais fonctionnement de l'appareil. Customer Support AcuRite customer support is committed to providing you with best-inclass service. For assistance, please have the model number of this product available and contact us in any of the following ways: (877) 221-1252 info@chaney-inst.com 24/7 support at www.AcuRite.com Ź Installation Videos Ź Instruction Manuals Ź Replacement Parts Ź Register your Product Ź Support User Forum Ź Submit Feedback & Ideas PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE IMPORTANT PRODUCT REGISTRATION Register online to receive 1 year warranty protection www.AcuRite.com Limited One Year Warranty At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. ŹRegister a Product and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney. The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of Ûtness for a particular purpose. Chaney expressly disclaims all liability for special, consequential or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation We recommend that you visit us at www.AcuRite. or exclusion may not apply to you. Chaney further disclaims all com for the fastest way to register your product. liability from personal injury relating to its products to the extent However, product registration does not eliminate permitted by law. By acceptance of any of Chaneys products, the purchaser assumes all liability for the consequences arising the need to retain your original proof of from their use or misuse. No person, Ûrm or corporation is purchase in order to obtain warranty beneÛts. authorized to assume for Chaney any other liability in connection Chaney Instrument Co. warrants that all products it manufactures with the sale of its products. Furthermore, no person, Ûrm or corporation is authorized to modify or waive the terms of this to be of good material and workmanship, and to be free of paragraph, and the preceding paragraph, unless done in writing defects when properly installed and operated for a period of and signed by a duly authorized agent of Chaney. This warranty one year from the date of purchase. Remedy for breach of this gives you speciÛc legal rights, and you may also have other warranty is limited to repair or replacement of the defective rights which vary from state to state. item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE For in-warranty claims: Chaney Instrument Co. YEAR from date of sale will, upon examination by Chaney, 965 Wells St., Lake Geneva, WI 53147 and at its sole option, be repaired or replaced by Chaney. Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear Weather Stations Temperature & Humidity Weather Alert Radio Kitchen Thermometers & Timers Clocks It’s More than Accurate, it’s AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to Plan your day with conÛdence™. www.AcuRite.com ©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyPrinted in China 00275 INST 052215 rights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : User Create Date : 2015:08:06 23:03:17+08:00 Modify Date : 2015:08:09 22:45:29+08:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2015:08:09 22:45:29+08:00 Creator Tool : Adobe InDesign CC 2014 (Macintosh) Instance ID : uuid:75da8566-8ad5-4747-b865-12c3effb80c9 Original Document ID : xmp.did:2E7F6188252168118A6DE1A4B05A3BCA Document ID : xmp.id:699419d9-55a6-493f-8ab7-7113498d8ae1 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:f66001c7-47ae-445f-8dc3-a56f10c67029 Derived From Document ID : xmp.did:56f66f20-33b5-4b23-81ce-98ea34fe6e8d Derived From Original Document ID: xmp.did:2E7F6188252168118A6DE1A4B05A3BCA Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Macintosh) History Changed : / History When : 2015:05:26 15:54:15-05:00 Format : application/pdf Title : INST15_00275RM-请确认.pdf Creator : User Producer : Acrobat Distiller 11.0 (Windows) Trapped : False Page Count : 6EXIF Metadata provided by EXIF.tools