Chaney Instrument RF100XTX Temperature and Humidity Transmitter User Manual
Chaney Instrument Co. Temperature and Humidity Transmitter Users Manual
user manual
Model No. Product Specification Model Name Version Effective Date Wireless Weather Station Model No.: 00611 / 00615 Product Specification Version 1.0 2007-1-2 00611 / 00615 Wireless Weather Station 1.0 1/2/2007 Model No. Design Summary Model Name Version Effective Date 00611 / 00615 Wireless Weather Station 4.0 12/6/2006 Contents 1. Foreword ........................................................................................................................................... 2 2. General Requirement ..................................................................................................................... 2 3. Product Specification .................................................................................................................... 2 4. Feature List....................................................................................................................................... 4 5. Communication Protocol .............................................................................................................. 4 6. Product Operation .......................................................................................................................... 6 Copyright © 2006 Primex of Companies - All rights reserved Page 1 of 6 Model No. Design Summary Model Name Version Effective Date 00611 / 00615 Wireless Weather Station 4.0 12/6/2006 1. Foreword The summarization is written for relative persons’ approval and record. 2. General Requirement 2.1 RoHS Compliance All materiel shall meet RoHS compliance. 2.2 FCC & IC Compliance and Certification 3. Product Specification 3.1 Humidity 3.1.1 Receiver (indoor readings) 3.1.1.1 Operating Temperature Range = 32F to 120F (0C to 50C) 3.1.1.2 Operating humidity range = 20% RH to 95% 3.1.1.3 Resolution = 1 % RH 3.1.2 Transmitter (receiver outdoor readings) 3.1.2.1 Operating Temperature Range = 32F to 122F (0C to 50C) 3.1.2.2 Operating Humidity Range = 20% RH to 95% RH 3.1.2.3 Resolution = 1 % RH 3.2 Temperature 3.2.1 Receiver 3.2.1.1 Operating temperature range = 32 F to 122 F (0C to 50C) 3.2.1.2 Resolution = 1 degree F 3.2.2 Transmitter 3.2.2.1 Operating Temperature Range = -40 F to 158 F (-40C to 70C) 3.2.2.2 Resolution = 1 degree F 3.3 Transmitter / Receiver: 3.3.1 Radio Frequency = 433MHz (Up to FCC 15.231 e) 3.3.2 Transmission time = approximately 100ms 3.3.3 Transmission intervals = approximately 16s 3.4 Operating Voltage Range 3.4.1 Receiver: 3.6V-4.5V (3*AA) 3.4.2 Transmitter: 2.4V-3.0V (2*AA) Copyright © 2006 Primex of Companies - All rights reserved Page 2 of 6 Transmitter: FCC ID RNERF100XTX Model No. Model Name Design Summary Version Effective Date 00611 / 00615 Wireless Weather Station 4.0 12/6/2006 4. Feature List 4.1 Receiver 4.1.1 Indoor Humidity / Temperature 4.1.2 Outdoor Temperature and Humidity Display 4.1.3 Outdoor today’s high / low Temperature Display 4.1.4 Today’s high / low temperature display icon 4.1.5 Outdoor Temperature Trend Line Display 4.1.6 C/F Slide Switch 4.1.7 ID A, B, C Slide Switch 4.1.8 The Display Icon of Reception Signal Strength -115 dB 4.2 Transmitter 4.2.1 Outdoor Temperature / Humidity 4.2.2 C/F button - Inside Search Button (This function is used for manufactory) 4.2.3 ID A, B, C Slide Switch 5. Communication Protocol 5.1 Data Format 5.1.1 Format There are two data types – Data 1, Data 2. The duration time for each data is 610us Data 1: The duration time of High Level is 400us, The duration time of Low Level is 210us. Data 2: The duration time of High Level is 210us, The duration time of Low Level is 400us. 5.1.2 Preamble Format The preamble is 1 byte. There are 8 bits in the preamble. It is made up of 4 high levels (610us) and 4 low levels (610us) as below figure. It is transmitted from high level. Copyright © 2006 Primex of Companies - All rights reserved Page 4 of 6 Model No. Model Name Design Summary Version Effective Date 00611 / 00615 Wireless Weather Station 4.0 12/6/2006 5.1.3 Data Rate Analysis 5.1.3.1 Data Rate is 1.64Kbps 5.1.3.2 There are 8 bytes every transmission. The total is 64bits. The duration time for each transmission is 610us * 64 +x= 100ms. 5.1.3.3 If repeatedly transmit multi-group data, then the transmission duration time is 610us * 8 * 7=34.16 ms for each additional data. The preamble does not repeatedly be transmitted in each data. One cycle (transmit times 100ms) 5.2 Data Package Format bit 10 11 12 13 14 15 16 17 18 19 20 21 22 23 data def. Preamble ID1 ID2 total 8 bits 8 bits 8 bits bit 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 data def. Message type & Length Data0 Data1 total 8 bits 8 bits 8 bits bit 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 data def. Data2 Check sum total 8 bits 8 bits 5.2.1 The transmission interval is T=X+Y X is above 15 positive integer, the time unit is second. It lies on Message type. Y is one of following figures 0, 125, 250, 375, 500, 625, 750, 850. The time unit is ms. 5.3 Data Package Definition Def. Message type Data0 Data1 Data2 Bit TEMP/HUMI Humidity UT2 Temperature Humidity UT3 Temperature Interval X Unit: s RF433: 16 Copyright © 2006 Primex of Companies - All rights reserved Page 5 of 6 Model No. Design Summary Model Name Version Effective Date 00611 / 00615 Wireless Weather Station 4.0 12/6/2006 reserve reserve reserve reserve reserve reserve 6. 7. Product Operation 7.1 Receiver 7.1.1 Key Function 7.1.1.1 There is one slide switch to select C/F unit. 7.1.1.2 There is one slide switch to select ID A, B, C. 7.1.2 When Power on or reset the LCD will full display for 3 seconds, the unit start to work. 7.1.3 The unit will detect the temperature and humidity every 30s. 7.1.4 Indoor Humidity Calculation and Display 7.1.5 Indoor Temperature Display 7.1.6 The outdoor temperature and humidity will be displayed when the signal is picked up, and the High/Low temperature is displayed at the same time. 7.1.7 Display of high and low outdoor temperatures is to be a rolling 24-48 hour value as follows: 7.1.8 Trend lines (increasing decreasing steady) 7.1.9 RF433 Reception When power on the receiver, the unit will turn on the RF module to looking for the RF signal, the RF433 reception bars cycles (i.e. one bar, two bars, three bars…….one bar, two bars … etc.) This continues until the unit receives a valid signal or for maximum 6 minutes if no signal is captured. 7.2 Transmitter (FCC ID: RNERF100XTX) 7.2.1 Key Function 7.2.1.1 A C/F button (search button) is added inside the transmitter. 7.2.1.2 A slide switch with A, B, C position is to select A, B, C channel. The factory default setting is A. 7.2.4 The unit will detect the temperature and humidity every 16s. 7.2.5 Outdoor Humidity Calculation and display in the receiver 7.2.6 Outdoor Temperature Display in the receiver Copyright © 2006 Primex of Companies - All rights reserved Page 6 of 6 This device complies with part 15of the FCC Rules and RSS-210 of IC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-701 About : uuid:0b29c5a3-6584-449b-ab88-b21d9c9c25dc Producer : Acrobat Distiller 6.0 (Windows) Company : Source Modified : D:20070131062432 Create Date : 2007:03:09 09:23:52+08:00 Creator Tool : Acrobat PDFMaker 6.0 Word 版 Modify Date : 2008:12:08 16:14:56+08:00 Metadata Date : 2008:12:08 16:14:56+08:00 Document ID : uuid:ad832529-9374-447e-97a5-5df21d1a73e8 Instance ID : uuid:bf7c11a9-d9ef-4f02-a56f-25e4b81b99d5 Version ID : 22 Format : application/pdf Title : 概要设计说明书的编写 Creator : KELVIN Subject : Headline : Page Count : 8 Author : KELVINEXIF Metadata provided by EXIF.tools