  Wireless Data Transceiver     E90-DTU                        This manual may be modified based on product upgrade, please refer to the latest version. All rights to interpret and modify this manual belong to Chengdu Ebyte Electronic Technology Co., Ltd. User Manual
Ebyte wireless data transceiver                                                                                         E90-DTU series user manual .                                                                                                                                        2 1.Introduction                                                                                   1.1. Brief introduction E90-DTU series are wireless data transceivers of 868M/915MHz with standard RS232/RS485 connectors. They are half-duplex TX & RX modems with GFSK modulation, which largely lower frequency bandwidth thus enable its strong anti-interference ability. Transparent transmission mode is available. Voltage supply ranges from 10V to 28V, convenient for users to install and debug. E90-DTU features FEC algorism, which enables higher coding efficiency and correction ability. The interfered data packets will be corrected proactively upon sudden interference, which significantly improves reliability and communication distance. Without FEC, the interfered data packet will be dropped. The  transceivers  feature  data  encryption  and  compression.  The  data  transmitted  in  air  features  randomness,  the  rigorous  algorism  makes  data interception meaningless. The data compression function has possibility to reduce the data transmission time, which in turn reduces the possibility of being interfered, thus improves the reliability and communication efficiency.   As  a communication media,  similar as optical  fiber, microwave and  cable, the  wireless data  transceiver  can be applied in specific scope:  it provides real-time and reliable data transmission of specific network monitor signal under some special conditions, it features cost-efficiency, easy installation, simple maintenance, super diffraction ability, flexible networking structure, large area covering and so on. It is suitable for multiple points under complex environment, and it is applicable for connecting with PLC, RTU, hyetometer, level gauge and so on. E90-DTU series strictly follow FCC, CE, CCC standards, and meet various certification requirements and can be applied all over the world. 1.2. Features ★ All core components are originally imported, our transceiver modems have much advanced functions with smaller size and lower cost. ★ TX power100mW, all technical parameters meet European industrial standards. ★ Temperature compensators are adopted to make the frequency stability better than  ±1.5PPM. ★ Operation temperature range: -40℃~+85℃, applicable for various harsh environment, it is real industrial grade products. ★ Aluminum alloy case, compact size, great heat dispersion; good shielding, prime electromagnetic compatibility and strong anti-interference. ★ Power reverse & overload protection and antenna surge protection functions significantly improve the reliability. ★ Parameters can be configured by programming, such as TX power, frequency point, air data rate, address and so on. ★ Ultra-low power consumption, standby current is only 50mA (even lower under power-saving and sleep modes). ★ Embedded watch-dog and precise time layout, modem will restart automatically upon abnormal situation and work with previous parameters. ★ The transceivers adopt original Silicon Labs SI4463/SI4438/SI4464 chips, customers highly comment the products because of the super reliability.
Ebyte wireless data transceiver                                                                                         E90-DTU series user manual .                                                                                                                                        3 2. Dimension  2.1    Description     Pin NO. Name Function Description 1  DB-9 female socket  RS-232 Standard RS-232 interface 2  3.81 terminal  RS-485、power interface  Standard RS-485 interface and pressure line power interface 3  PWR-LED  Power LED  Red, lit when the power is on 4  TXD-LED  Transmit LED  Yellow, blinks when sending data 5  RXD-LED  Receive LED  Yellow, blinks when sending data 6  DC power interface  Power interface  In-line round hole, outer diameter 5.5mm, diameter 2.5mm 7  DIP switch  Dip switch    Controlled by working mode 8  Antenna interface  SMA-K interface  external thread, 10mm, 50Ωcharacteristic impedance
Ebyte wireless data transceiver                                                                                         E90-DTU series user manual .                                                                                                                                        4 2.2. Dimension of type A   ★Note:Type A is for 2W specification,including:               E90-DTU(868M20)      E90-DTU(915M20)
Ebyte wireless data transceiver                                                                                         E90-DTU series user manual .                                                                                                                                        5 3. Interface definition 3.1. Power interface   Users can choose  ⑥  DC power interface,using the power adapter supply with the interface of the 5.5mm outer diameter , 2.5mm diameter ; Also choose the VCC and GND terminal power supply, only choose any one of the power supply is OK; E90-DTU can use 10 ~ 28V DC power supply, but it is recommended to use 12V or 24V DC power supply. 3.2. RS232 interface The E90-DTU can be connected to the device via RS-232 using the standard DB-9 interface. 3.3. RS485 interface E90-DTU can connect the 485_A terminal and 485_B terminal with the device RS-485 A terminal and B terminal.   Pin NO. Definition Function Description 1 VCC Pressure line power interface, positive   10 ~ 28V DC, recommended 12V or 24V 2 GND Pressure line power interface, negative The power supply negative pole is connected to the system ground and the housing 3 485_B RS-485 interface, interface B   The RS-485 interface B is connected to the device interface B 4 485_A RS-485 interface, interface A The RS-485 interface A is connected to the device interface A
Ebyte wireless data transceiver                                                                                         E90-DTU series user manual .                                                                                                                                        6 ★ Note: The transceiver will be poor communication when connecting multiple devices , while connecting a single device is not, please try to parallel connect 120Ω  resistor between 485_A terminal and 485_B. 4. Technical specification 4.1. Model specification Model Frequency  TX power  Distance Features  Recommended applications MHz  W  km E90-DTU(868M20) 868  0.1  2  North America band, FEC, Stable performance Applicable for living, industrial areas and open mountain area with a few obstacles E90-DTU(915M20) 907-922.5  0.1  2 European band,FEC, Stable performance Applicable for living, industrial areas and open mountain area with a few obstacles  ★ Note: Test conditions: clear weather, open area, no blockage, 12V1A power, 5dBi gain sucker antenna, 2 meters above ground, default parameters 4.2. General parameters Model Size Weight Temperature Impedance Voltage Interface Baud rate Address code E90-DTU(868M20)  82 * 62 * 25mm  131g±3g  -40 ~ 85℃ 50  Ω  8 ~ 28V DC  RS232/RS485  Default 9600  Default 0 E90-DTU(915M20)  82 * 62 * 25mm  131g±3g  -40 ~ 85℃ 50  Ω  8 ~ 28V DC  RS232/RS485  Default 9600  Default 0  ★ Notes: Operating temperature: it is recommended to be lower than 70℃. Antenna impedance: standard 50Ω  characteristic impedance. Voltage: higher than max value will damage the transceiver. Communication interface: standard DB9 hole/3.81 terminal. Baud rate: 1200~115200. Address: 65536 addresses. 4.3. Frequency and Channel Model Default Frequency  Frequency Band  Channel Interval Channel MHz  MHz  MHz E90-DTU(868M20) 868  855~880.5  0.1  256,half duplex E90-DTU(915M20) 907-922.5  900~925.5  0.1  31 ,half duplex  ★ Notes: When multiple pairs work in same area, please set at least 2MHz channel interval between each pair to avoid interference. 4.4. Transmitting power   Model  10mw  25mW  50mW  64mW  100mW  125mW  250mW  500mW  5W E90-DTU(868M20) √ √ √    √         E90-DTU(915M20) √ √ √    √          ★ Notes: The lower the TX power, the shorter the communication distance. The current will not decrease at equal scale. Max power is recommended. 907 MHzÿ922.5 MHz
Ebyte wireless data transceiver                                                                                         E90-DTU series user manual .                                                                                                                                        7 4.5. Air data rate Model Default air data rate                 Level AIr data rate Kbps  kbps E90-DTU(868M20)  1  8  1、2、5、8、10、15、20、25 E90-DTU(915M20)  1  8  1、2、5、8、10、15、20、25  ★ Notes: The higher the air rate, the quicker the transmission and the shorter the distance. So lower air rate is recommended.  4.6. Current value Model Transmitting current mA  Stand-by current mA 12V DC  24V DC  12V DC  24V DC E90-DTU(868M20) 93 62 18 25 E90-DTU(915M20) 89 60 16 22  ★ Notes: At least 50% current allowance is recommended when selecting power source in order to ensure long-term stable operation. 4.7. TX/RX length and sub-packing Model Buffer  Sub-packing E90-DTU(868M20)  512 bytes  Auto sub-packing 58 bytes E90-DTU(915M20)  512 bytes  Auto sub-packing 58 bytes  ★ Notes   1. If single data packet is beyond allowed volume (100 bytes), the exceeded data will be left to the second transmission until it is sent completely. 2. The single RX data packet should not exceed the flash volume. 5. Operation Modes E90-DTU transceivers have four operation modes. Please configure to general mode (M0) if no harsh low consumption required. The transceivers are set to general mode (M0) by default.     Mode  M1 M0  Notes Mode 0  Common mode  On On Serial port open, RF on, transparent transmission Mode 1  Wake-up mode  On Off  Wake-on-air TX mode, data packet includes wake-up codes Mode 2  Power-saving mode  Off On  Wake-up RX mode, saving RX power, TX not allowed Mode 3  Sleep mode  Off Off  In sleep mode, configuration commands allowed
Ebyte wireless data transceiver                                                                                         E90-DTU series user manual .                                                                                                                                        8 6. Connection Diagram for Configuration        Mode  M1 M0  Notes Mode 0  General mode  On On  Serial port open, RF on, transparent transmission Mode 1  Wake-up mode  On Off  Wake-on-air TX mode, data packet includes wake-up codes Mode 2  Power-saving mode  Off On  Wake-up RX mode, saving RX power, TX not allowed Mode 3  Sleep mode  Off Off  In sleep mode, configuration commands allowed  ★ Notes: Configuration is allowed only under specific mode (refer to above table), please make sure the transceiver is under correct mode. 7. Connection Diagram for Testing & Operation
Ebyte wireless data transceiver                                                                                         E90-DTU series user manual .                                                                                                                                        9  8. Applicable Industries  Ebyte wireless data transceiver is applicable for kinds of point-to-point, point-to-multipoint transmission systems, such as smart home, IoT upgrade, power grid load monitor, networking automation, utility water pipeline monitor, hydrology measuring, city lights monitor, air warning control, railway signal monitor, railway water supply control, oil & gas pipeline monitor, GPS positioning system, remote meter reading, electronic crane scale, automatic scoring system, earthquake reporting and so on. Please refer to below figure:   9. Important Notes   1. Please do not operate the devices at or near inflammable or explosive areas. 2. Please select stable DC power supply sources, which should have strong anti-interference ability and low ripple as well as load capacity; it is better to have overcurrent or overvoltage and lightning protection in order to ensure normal operation. 3. Please  do  not  use  the  devices  at  environment  that  exceeds  the  limitation  such  as  high  temperature,  high  humidity,  low  temperature,  strong electromagnetic or dusty environment. 4. Please do not make the devices work continuously at overload status, or it will damage the devices. 5. The ground electrode of the transceiver should be connected firmly to the external device’s (PC, PLC, ETC.) and power source ground electrode, or it is easy to damage the communication interfaces; please do not plug on or off the serial port with power on. 6. When testing the transceivers, matched antennas or 50Ω  dummy load must be connected, or it is easy to damage the devices; if antenna connected, human body should be at least 2 meters from the antenna to avoid injury, and do not touch the antenna when it is transmitting. 7. Under  different environment, the  communication distance will be  different. Communication distance will  be affected by temperature, humidity, blockage density, blockage size and electromagnetic environment; in order to have stable communication, at least 50% communication allowance is recommended to be kept.   8. If the tested communication distance is not ideal, please also consider about improving the antenna quality and antenna installation. Or please
Ebyte wireless data transceiver                                                                                         E90-DTU series user manual .                                                                                                                                        10 contact support@cdebyte.com for help. 9. When selecting power source, besides keeping at least 50% current allowance, please also keep the power ripple below 100mV.    10. Important Declarations   All rights to interpret and modify this manual belong to Ebyte.  This manual will be updated based on the upgrade of firmware and hardware, please refer to the latest version.  Please refer to our website for new product information.                        Technical support: support@cdebyte.com Documents and RF Setting Software downloading: www.cdebyte.com ———————————————————————————————————————————————————————————————— Tel: +86-28-61399028 (ext. 812) Fax: +86-28-64146160 Web: www.cdebyte.com Address:Innovation Center D347, 4# XI-XIN Road,Chengdu, Sichuan, China
FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2)  This  device  must  accept  any  interference  received,  including  interference  that  may  cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE:   This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This  equipment generates  uses  and can  radiate  radio  frequency  energy  and, if  not  installed  and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment  does  cause  harmful  interference  to  radio  or  television  reception,  which  can  be determined  by  turning  the  equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  the  receiver  is connected.   Consult the dealer or an experienced radio/TV technician for help.  RF Exposure warning:  The distance between device include antenna and user should be no less than 20 cm.

Navigation menu