Chengdu Ebyte Electronic Technology E90-DTU Wireless transceiver module User Manual

Chengdu Ebyte Electronic Technology Co., Ltd. Wireless transceiver module Users Manual

User manual

Download: Chengdu Ebyte Electronic Technology E90-DTU Wireless transceiver module User Manual
Mirror Download [FCC.gov]Chengdu Ebyte Electronic Technology E90-DTU Wireless transceiver module User Manual
Document ID3918806
Application ID8Py5o7sNovywQw4YkqGN1A==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize91.72kB (1146541 bits)
Date Submitted2018-07-10 00:00:00
Date Available2018-07-10 00:00:00
Creation Date2018-07-10 09:43:39
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2018-07-10 08:21:49
Document TitleUsers Manual
Document CreatorMicrosoft® Word 2016
Document Author: Administrator

Wireless Data Transceiver
E90-DTU
User Manual
This manual may be modified based on product upgrade, please refer to the latest version.
All rights to interpret and modify this manual belong to Chengdu Ebyte Electronic Technology Co., Ltd.
Ebyte wireless data transceiver
E90-DTU series user manual
1.Introduction
1.1. Brief introduction
E90-DTU series are wireless data transceivers of 868M/915MHz with standard RS232/RS485 connectors. They are half-duplex TX & RX modems with
GFSK modulation, which largely lower frequency bandwidth thus enable its strong anti-interference ability. Transparent transmission mode is available.
Voltage supply ranges from 10V to 28V, convenient for users to install and debug.
E90-DTU features FEC algorism, which enables higher coding efficiency and correction ability. The interfered data packets will be corrected proactively
upon sudden interference, which significantly improves reliability and communication distance. Without FEC, the interfered data packet will be dropped.
The transceivers feature data encryption and compression. The data transmitted in air features randomness, the rigorous algorism makes data
interception meaningless. The data compression function has possibility to reduce the data transmission time, which in turn reduces the possibility of
being interfered, thus improves the reliability and communication efficiency.
As a communication media, similar as optical fiber, microwave and cable, the wireless data transceiver can be applied in specific scope: it provides
real-time and reliable data transmission of specific network monitor signal under some special conditions, it features cost-efficiency, easy installation,
simple maintenance, super diffraction ability, flexible networking structure, large area covering and so on. It is suitable for multiple points under complex
environment, and it is applicable for connecting with PLC, RTU, hyetometer, level gauge and so on.
E90-DTU series strictly follow FCC, CE, CCC standards, and meet various certification requirements and can be applied all over the world.
1.2. Features
★
All core components are originally imported, our transceiver modems have much advanced functions with smaller size and lower cost.
★
TX power100mW, all technical parameters meet European industrial standards.
★
Temperature compensators are adopted to make the frequency stability better than ±1.5PPM.
★
Operation temperature range: -40℃~+85℃, applicable for various harsh environment, it is real industrial grade products.
★
Aluminum alloy case, compact size, great heat dispersion; good shielding, prime electromagnetic compatibility and strong anti-interference.
★
Power reverse & overload protection and antenna surge protection functions significantly improve the reliability.
★
Parameters can be configured by programming, such as TX power, frequency point, air data rate, address and so on.
★
Ultra-low power consumption, standby current is only 50mA (even lower under power-saving and sleep modes).
★
Embedded watch-dog and precise time layout, modem will restart automatically upon abnormal situation and work with previous parameters.
★
The transceivers adopt original Silicon Labs SI4463/SI4438/SI4464 chips, customers highly comment the products because of the super reliability.
Ebyte wireless data transceiver
2.
Dimension
2.1
Description
E90-DTU series user manual
Pin NO.
Name
Function
Description
DB-9 female socket
RS-232
Standard RS-232 interface
3.81 terminal
RS-485、power interface
Standard RS-485 interface and pressure line power interface
PWR-LED
Power LED
Red, lit when the power is on
TXD-LED
Transmit LED
Yellow, blinks when sending data
RXD-LED
Receive LED
Yellow, blinks when sending data
DC power interface
Power interface
In-line round hole, outer diameter 5.5mm, diameter 2.5mm
DIP switch
Dip switch
Controlled by working mode
Antenna interface
SMA-K interface
external thread, 10mm, 50Ωcharacteristic impedance
Ebyte wireless data transceiver
E90-DTU series user manual
2.2. Dimension of type A
★Note:Type A is for 2W specification,including:
E90-DTU(868M20)
E90-DTU(915M20)
Ebyte wireless data transceiver
E90-DTU series user manual
3. Interface definition
3.1. Power interface
Users can choose ⑥ DC power interface,using the power adapter supply with the interface of the 5.5mm outer diameter , 2.5mm
diameter ;
Also choose the VCC and GND terminal power supply, only choose any one of the power supply is OK;
E90-DTU can use 10 ~ 28V DC power supply, but it is recommended to use 12V or 24V DC power supply.
3.2. RS232 interface
The E90-DTU can be connected to the device via RS-232 using the standard DB-9 interface.
3.3. RS485 interface
E90-DTU can connect the 485_A terminal and 485_B terminal with the device RS-485 A terminal and B terminal.
Pin NO.
Definition
Function
Description
VCC
Pressure line power interface, positive
10 ~ 28V DC, recommended 12V or 24V
GND
Pressure line power interface, negative
485_B
RS-485 interface, interface B
The RS-485 interface B is connected to the device interface B
485_A
RS-485 interface, interface A
The RS-485 interface A is connected to the device interface A
The power supply negative pole is connected to the system
ground and the housing
907 MHzÿ922.5 MHz
Ebyte wireless data transceiver
★
E90-DTU series user manual
Note: The transceiver will be poor communication when connecting multiple devices , while connecting a single device is not, please
try to parallel connect 120Ω resistor between 485_A terminal and 485_B.
4. Technical specification
4.1. Model specification
Frequency
TX power
Distance
MHz
km
868
0.1
0.1
Model
E90-DTU(868M20)
E90-DTU(915M20)
★
907-922.5
Features
Recommended applications
North America band, FEC, Stable
Applicable for living, industrial areas and open mountain
performance
area with a few obstacles
European band,FEC, Stable
Applicable for living, industrial areas and open mountain
performance
area with a few obstacles
Note: Test conditions: clear weather, open area, no blockage, 12V1A power, 5dBi gain sucker antenna, 2 meters above ground, default parameters
4.2. General parameters
Model
Size
Weight
Temperature
Impedance
Voltage
Interface
Baud rate
Address code
E90-DTU(868M20)
82 * 62 * 25mm
131g±3g
-40 ~ 85℃
50 Ω
8 ~ 28V DC
RS232/RS485
Default 9600
Default 0
E90-DTU(915M20)
82 * 62 * 25mm
131g±3g
-40 ~ 85℃
50 Ω
8 ~ 28V DC
RS232/RS485
Default 9600
Default 0
★
Notes: Operating temperature: it is recommended to be lower than 70℃. Antenna impedance: standard 50Ω characteristic impedance. Voltage:
higher than max value will damage the transceiver. Communication interface: standard DB9 hole/3.81 terminal. Baud rate: 1200~115200. Address:
65536 addresses.
4.3. Frequency and Channel
Default Frequency
Frequency Band
Channel Interval
MHz
MHz
MHz
E90-DTU(868M20)
868
855~880.5
0.1
256,half duplex
E90-DTU(915M20)
907-922.5
900~925.5
0.1
31 ,half duplex
Model
★
Channel
Notes: When multiple pairs work in same area, please set at least 2MHz channel interval between each pair to avoid interference.
4.4. Transmitting power
Model
10mw
25mW
50mW
E90-DTU(868M20)
√
√
√
√
E90-DTU(915M20)
√
√
√
√
★
64mW
100mW
125mW
250mW
500mW
5W
Notes: The lower the TX power, the shorter the communication distance. The current will not decrease at equal scale. Max power is recommended.
Ebyte wireless data transceiver
E90-DTU series user manual
4.5. Air data rate
Default air data rate
AIr data rate
Model
Level
Kbps
kbps
E90-DTU(868M20)
1、2、5、8、10、15、20、25
E90-DTU(915M20)
1、2、5、8、10、15、20、25
★
Notes: The higher the air rate, the quicker the transmission and the shorter the distance. So lower air rate is recommended.
4.6. Current value
Transmitting current mA
Stand-by current mA
Model
12V DC
24V DC
12V DC
24V DC
E90-DTU(868M20)
93
62
18
25
E90-DTU(915M20)
89
60
16
22
★
Notes: At least 50% current allowance is recommended when selecting power source in order to ensure long-term stable operation.
4.7. TX/RX length and sub-packing
★
Model
Buffer
Sub-packing
E90-DTU(868M20)
512 bytes
Auto sub-packing 58 bytes
E90-DTU(915M20)
512 bytes
Auto sub-packing 58 bytes
Notes
1. If single data packet is beyond allowed volume (100 bytes), the exceeded data will be left to the second transmission until it is sent completely.
2. The single RX data packet should not exceed the flash volume.
5. Operation Modes
E90-DTU transceivers have four operation modes. Please configure to general mode (M0) if no harsh low consumption required.
The transceivers are set to general mode (M0) by default.
Mode
M1
M0
Notes
Mode 0
Common mode
On
On
Serial port open, RF on, transparent transmission
Mode 1
Wake-up mode
On
Off
Wake-on-air TX mode, data packet includes wake-up codes
Mode 2
Power-saving mode
Off
On
Wake-up RX mode, saving RX power, TX not allowed
Mode 3
Sleep mode
Off
Off
In sleep mode, configuration commands allowed
Ebyte wireless data transceiver
E90-DTU series user manual
6. Connection Diagram for Configuration
★
Mode
M1
M0
Notes
Mode 0
General mode
On
On
Serial port open, RF on, transparent transmission
Mode 1
Wake-up mode
On
Off
Wake-on-air TX mode, data packet includes wake-up codes
Mode 2
Power-saving mode
Off
On
Wake-up RX mode, saving RX power, TX not allowed
Mode 3
Sleep mode
Off
Off
In sleep mode, configuration commands allowed
Notes: Configuration is allowed only under specific mode (refer to above table), please make sure the transceiver is under correct mode.
7. Connection Diagram for Testing & Operation
Ebyte wireless data transceiver
E90-DTU series user manual
8. Applicable Industries
Ebyte wireless data transceiver is applicable for kinds of point-to-point, point-to-multipoint transmission systems, such as smart home, IoT upgrade,
power grid load monitor, networking automation, utility water pipeline monitor, hydrology measuring, city lights monitor, air warning control, railway
signal monitor, railway water supply control, oil & gas pipeline monitor, GPS positioning system, remote meter reading, electronic crane scale, automatic
scoring system, earthquake reporting and so on. Please refer to below figure:
9. Important Notes
1.
Please do not operate the devices at or near inflammable or explosive areas.
2.
Please select stable DC power supply sources, which should have strong anti-interference ability and low ripple as well as load capacity; it is better to
have overcurrent or overvoltage and lightning protection in order to ensure normal operation.
3.
Please do not use the devices at environment that exceeds the limitation such as high temperature, high humidity, low temperature, strong
electromagnetic or dusty environment.
4.
Please do not make the devices work continuously at overload status, or it will damage the devices.
5.
The ground electrode of the transceiver should be connected firmly to the external device’s (PC, PLC, ETC.) and power source ground electrode, or
it is easy to damage the communication interfaces; please do not plug on or off the serial port with power on.
6.
When testing the transceivers, matched antennas or 50Ω dummy load must be connected, or it is easy to damage the devices; if antenna connected,
human body should be at least 2 meters from the antenna to avoid injury, and do not touch the antenna when it is transmitting.
7.
Under different environment, the communication distance will be different. Communication distance will be affected by temperature, humidity,
blockage density, blockage size and electromagnetic environment; in order to have stable communication, at least 50% communication allowance is
recommended to be kept.
8.
If the tested communication distance is not ideal, please also consider about improving the antenna quality and antenna installation. Or please
Ebyte wireless data transceiver
E90-DTU series user manual
contact support@cdebyte.com for help.
9.
When selecting power source, besides keeping at least 50% current allowance, please also keep the power ripple below 100mV.
10. Important Declarations

All rights to interpret and modify this manual belong to Ebyte.

This manual will be updated based on the upgrade of firmware and hardware, please refer to the latest version.

Please refer to our website for new product information.
Technical support: support@cdebyte.com
Documents and RF Setting Software downloading: www.cdebyte.com
————————————————————————————————————————————————————————————————
Tel: +86-28-61399028 (ext. 812)
Fax: +86-28-64146160
Web: www.cdebyte.com
Address:Innovation Center D347, 4# XI-XIN Road,Chengdu, Sichuan, China
10
FCC Statement
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
RF Exposure warning:
The distance between device include antenna and user should be no less than 20 cm.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Language                        : zh-CN
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : Administrator
Title                           : 成都亿佰特电子科技有限公司
Create Date                     : 2018:07:10 09:43:39+08:00
Creator Tool                    : Microsoft® Word 2016
Modify Date                     : 2018:07:10 08:21:49-04:00
Metadata Date                   : 2018:07:10 08:21:49-04:00
Producer                        : Microsoft® Word 2016
Document ID                     : uuid:af129cb5-8a34-41f7-a023-597e0c3ee64b
Instance ID                     : uuid:54c80f36-0c45-439c-ad19-c6734421aa0e
Page Count                      : 11
Author                          : Administrator
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ALPH-E90-DTU