Chengdu Vantron Technology VTM2M-TC M2M Gateway User Manual
Chengdu Vantron Technology, Ltd. M2M Gateway
Contents
- 1. User Manual
- 2. Users Manual
User Manual
VT‐M2M‐TC User’s Manual Vantron Technology www.vantrontech.com.cn All Rights Reserved VT-M2M-TC Revision History: No. Version V1.0 V1.1 V1.2 V1.3 V1.4 V1.5 V1.6 V1.7 V1.8 Description First release Add GPIO Information Modify order information Modify order information Update the logo of cover Add 1xHalf PCIe slot Add FCC and IC warning statement Change power input description as DC9‐36V(default 12V) Appended contents of how to do software setup Date May 10, 2011 Dec. 22, 2011 Nov. 18, 2011 Jan. 10, 2012 May 16, 2012 July 20, 2012 Dec. 2, 2013 Dec. 16, 2013 Jan 16, 2014 VT-M2M-TC Table of Contents Part I:Hardware Platform .............................................................. 4 Foreword ..................................................................................... 5 1.1 Copyright Notice ...................................................................... 5 1.2 Notes ........................................................................................ 6 1.3 Statement ................................................................................ 6 1.4 Disclaimer ................................................................................ 6 1.5 Limitation of Liability/Non‐warranty........................................ 7 1.6 Safety Instructions ................................................................... 7 1.7 Precautions .............................................................................. 8 1.8 Safety Instructions for Power Cables and Accessories ............. 9 Overview.................................................................................... 11 2.1 Introduction ........................................................................... 11 2.2 Product Series ........................................................................ 12 2.2.1 Product Order Coding Rule ...................................... 12 2.2.2 Ordering Information .............................................. 12 M2M‐TC Hardware Instructions .................................................. 13 3.1 Product Appearance .............................................................. 13 3.2 Specifications ......................................................................... 16 3.3 Interface Instructions ............................................................. 18 3.3.1 Front View ............................................................... 18 3.3.2 Back View ................................................................ 18 3.4 Dimension .............................................................................. 19 3.5 Interface Description.............................................................. 20 3.5.1 Wide‐Range Power Interface .................................. 20 3.5.2 Ethernet Interface ................................................... 20 VT-M2M-TC 3.6 3.5.3 D Sub‐9 RS232 Connector........................................ 21 3.5.4 RS232/485 ,CAN,External IO Connector ................... 22 3.5.5 VGA Interface .......................................................... 23 3.5.6 USB Host Connector ................................................ 24 Operation Notice.................................................................... 25 3.6.1 Change SIM Card ..................................................... 25 3.6.2 Power Supply ........................................................... 25 Tips .............................................................................................26 Part II:Software Platform ............................................................. 30 1 Introduction ............................................................................. 30 1.1 About This Manual ..................................................... 30 1.2 Sample Programs ........................................................ 31 1.3 Functionalities layout ................................................. 31 1.4 Linux OS Support ........................................................ 33 Base Control............................................................................. 34 2.1 Power Control ............................................................. 34 2.2 Can Control ................................................................. 35 2.3 Gpio Control ............................................................... 36 2.4 Serial COM Control ..................................................... 36 2.5 Audio Control................................................................. 37 2.6 SD card Control .............................................................. 37 2.7 ADXL345 Control......................................................... 38 WIFI Module ............................................................................. 39 3.1 BaseConfig .................................................................. 39 3.2 OpenConfig ................................................................. 40 3.3 WPA‐PSK/WPA2_PSK Config ...................................... 40 VT-M2M-TC 3G Module................................................................................. 42 4.1 BaseConfig .................................................................. 42 4.2 ScriptConfig ................................................................ 43 5ZigBee Module ............................................................................. 45 5.1DigiXbee Module ............................................................ 45 GPS Module .............................................................................. 48 6.1 Get GPS Data .............................................................. 48 6.2 GPS Data Format ........................................................ 48 7Update System ............................................................................ 56 7.1 Make USB boot Stick and Copy Image to USB stick .. 56 7.2 Update steps............................................................... 59 VT-M2M-TC Part I:Hardware Platform VT-M2M-TC Foreword 1.1 Copyright Notice While all information contained herein have been carefully checked to assure its accuracy in technical details and printing, Vantron assumes no responsibility resulting from any error or features of this manual, or from improper uses of this manual or the software. Please contact our technical department for relevant operation solutions if there is any problem that cannot be solved according to this manual. Vantron reserves all rights of this manual, including the right to change the content, form, product features, and specifications contained herein at any time without prior notice. The latest version of this manual is at www.vantrontech.com.cn. Please contact Vantron for further information: Vantron Technology Vantron E‐mail: sales@vantrontech.com VT-M2M-TC The trademarks and registered trademarks in this manual are properties of their respective owners. No part of this manual may be copied, reproduced, translated or sold. No changes or other purposes are permitted without the prior written consent of Vantron. Vantron reserves the right of all publicly‐released copies of this manual. 1.2 Notes Applicable notes are listed in the following table: Sign Notice Type Description Notice Important information and regulations Caution Caution for latent damage to system or harm to personnel 1.3 Statement It is recommended to read and comply with this manual before operating VT‐M2M TC which provides important guidance and helps decreasing the danger of injury, electric shock, fire, or any damage to the device. 1.4 Disclaimer Vantron assumes no legal liability of accidents resulting from failure of conforming to the safety instructions. VT-M2M-TC 1.5 Limitation of Liability/Non‐warranty For direct or indirect damage to this device or other devices of Vantron caused by failure of conforming to this manual or the safety instructions on device label, Vantron assumes neither warranty nor legal liability even if the device is still under warranty. The VT‐M2M‐TC should be installed, debugged and maintained by professional people. 1.6 Safety Instructions Keep and comply with all operation instructions, warnings, and information. Pay attention to warnings on this device. Read the following precautions so as to decrease the danger of injury, electric shock, fire, or any damage to the device. VT-M2M-TC 1.7 Precautions Pay attention to the product labels/safety instructions printed on silk screens. Do not try repairing this product unless declared in this manual. Keep away from heat source, such as heater, heat dissipater, or engine casing. Do not insert other items into the slot (if any) of this device. • Keep the ventilation slot ventilated for cooling. •System fault may arise if other items are inserted into this device. Installation: ensure correct installation according to instructions from the manufacturer with recommended installation tools. Ensure ventilation and smoothness according to relevant ventilation standard. VT-M2M-TC 1.8 Safety Instructions for Power Cables and Accessories Proper power source only Start only with power source that satisfies voltage label and the voltage necessary according to this manual. Please contact technical support personnel of Vantron for any uncertainty about the requirements of necessary power source. Use tested power source This product still contains a button lithium battery as a real‐time clock after its external power source is removed and therefore should not be short‐circuited during transportation or placed under high temperature. Place cables properly: Do not place cables at any place with extrusion danger. VT-M2M-TC Cleaning Instructions Please power off before cleaning the device. Do not use spray detergent. Clean with a damp cloth. Do not try cleaning exposed electronic components unless with a dust collector. Support for special fault: Power off and contact technical support personnel of Vantron in case of the following faults: ¾ The device is damaged. ¾ The temperature is excessively high. ¾ Fault is still not solved after the operation according to the manual. VT-M2M-TC Overview 2.1 Introduction Thank you for choosing Vantron. It is our commitment to provide our valued customers with the embedded devices equipped with the state‐of‐the‐art technology and the best product services. Vantron’s M2Mproducts are based on the most advanced ARM and Intel Atom processors and have low‐power consumption and high integration. The products are designed for applications of M2M in industrials, medicals, financial, retail, vehicle, and transportations etc. VT-M2M-TC 2.2 Product Series 2.2.1 Product Order Coding Rule Order Code VT-M2M-TC-4-1GM-8GF-GWZP-V Version: I: Extended Temperature Blank:Commercial temperature Wireless Module Option: 2G: 2G, 3G: 3G, W: WiFi, Z: Zigbee, P: GPS SSD Memory Size: 8G:8GB, 16G: 16GB DDR Memory Size: 5:512MB , 1G:1GB, 2G: 2GB CPU Speed: 2:600MHz, 4:1GHz, 6:1.3GHz:8:1.6GHz 2.2.2 Ordering Information Order Examples: VT-M2M-TC-4-1GM-8GF ATOM E640 Processor, 1GHz CPU, 1GB DDR2 VT-M2M-TC-6-1GM-8GF-W ATOM E640 Processor, 1.3GHz CPU, 1GB DDR2, 8G Flash, WLAN VT-M2M-TC-8-1GM-8GF-3GW ATOM E640 Processor, 1.6GHz CPU, 1GB DDR2, Accessories: Install Mechanical tools,1pc Power Adapter with locked connector (Optional),1pc IO Terminal (12x3.81mm) (Optional),1pc 3G Antenna(Optional),1pc WiFi Antenna(Optional),1pc Zigbee Antenna(Optional),1pc GPS Antenna(Optional),1pc 8G Flash , 3G,WLAN VT-M2M-TC M2M‐TC Hardware Instructions 3.1 Product Appearance Front Side View Back Side View VT-M2M-TC View for all optional embedded modules and antennas VT-M2M-TC Bottom View for optional embedded modules (1xHalf PCIe slot under the 1xPCIe slot) Bottom View for optional embedded modules VT-M2M-TC 3.2 Specifications Specifications CPU Processor Intel® ATOM™, E640(T)1GHz, E660(T)1.3GHz, E680(T),1.6GHz 32KB Instruction cache +23KB L1 cache, 512KB L2 cache Memory Display On Board DDR 1GB ( up to 2GB), 533MHz ROM Internal 1.8”SATA SSD Module Internal (8GB, or others) Chipset Intel® Platform Controller Hub EG20T. Resolution Up to 1280 x 1024 @ 60Hz for VGA Support LCD/SDVO, Simultaneous/dual view display Decode:H.264,MPEG4, MPEG2,VC1,WMV-9, Div-X Encode:H.264,MPEG4, Wireless Communication Peripheral Interfaces Interface 1xVGA (DB15) WLAN Optional 802.11 b/g/n Wireless Module, external 3G Module Optional1x mini PCIe 3G Broad Band Module with SIM ZigBee Optional low power Zigbee Module, external antenna GPS Optional GPS module, external antenna Ethernet 1x10/100/1000-BaseT(RJ45) USB 2xUSB2.0 Host (Type A) Audio HD Audio, 1xMIC in 3.5mm, 1xline Out 3.5mm 1xLVDS (Optional Internal) antenna , Support 1x Half PCIe Wireless card slot VT-M2M-TC COM Port 1xDB9 External, 1xRS232 Internal 1xCAN 2.0b Alarm Buzzer Out SD card 1xSD card Slot (Optional ) RTC Supported Control Reset Button on the top GPIO Reserved GPIO (Terminal) UART 1x full function UART use DB9 Security security On board Registration Serial Number, and SHA-1 Software OS Linux Applications SDK Available Power Input DC9-36V(default 12V), Locked Power Jack Consumption 6W (Pulse8W), Sleep 2W. (without Dimensions 138x102x52mm (Box) Install 160x102x52mm Weight 0.6Kg (1.2KKg package Kit) Enclosure Aluminum Alloy with Black Color Temperature Operating:-0°C ~ +60°C Mechanical Environment Condition Encrypt/Decrypt Chip DS28E01 (Optional) 3G,GPS,Zigbee,WLAN) ( ETR:-40°C ~ +80°C Optional) Storage: -20°C ~ +70°C, (ETR:-40°C ~ +85°C Optional) Humidity 5-95%RH at 25-35 (Non-Condensation) Cooling Mode Fan less, Heat Sink Approvals UL, FCC Class A, and CE VT-M2M-TC 3.3 Interface Instructions 3.3.1 Front View 3.3.2 Back View VT-M2M-TC 3.4 Dimension VT-M2M-TC 3.5 Interface Description 3.5.1 Wide‐Range Power Interface Power JACK with lock Pin Description 1,3 DGND (ground pin) Power (+12 DC,UP to 36V) 3.5.2 Ethernet Interface Standard RJ45 interface, supporting 10M/100M/1000M self‐adaptation, this is a standard RJ45 ethernet port VT-M2M-TC 3.5.3 D Sub‐9 RS232 Connector Standard vertical DB‐9 male connector Pin Description DCD1/422TX+/485_A Remarks BIOS set RXD1/422TX‐/485_B BIOS set TXD1/422RX+ BIOS set DTR1/422RX‐ BIOS set DGND (ground pin) DSR1 RTS1 CTS1 RI1 VT-M2M-TC 3.5.4 RS232/485 ,CAN,External IO Connector 12pins 3.81 pitch terminal with screw lock Load capacity: more than 128 nodes/RS485 channel Pin 10 11 12 Description TXD2/485_2_A RXD2/485_2_B DGND CANH CANL DGND EXTIO0 EXTIO1 EXTIO2 EXTIO3 EXTIO4 EXTIO5 Remarks BIOS set BIOS set 3.3V Level 3.3V Level 3.3V Level 3.3V Level 3.3V Level 3.3V Level VT-M2M-TC 3.5.5 VGA Interface Standard vertical DB‐15 Female VGA connector Pin 10 11 12 13 14 15 Description RED GREEN BLUE N.C. GND GND GND GND +5VDC GND N.C. SD_DDC HSYNC VHYNC SC_DDC VT-M2M-TC 3.5.6 USB Host Connector Dual vertical USB A type interface, USB2.0 Pin A1 A2 A3 A4 B1 B2 B3 B4 Description USB1_VCC(+5VDC) USB1_D‐ USB1_D+ USB1_DGND(ground pin) USB2_VCC(+5VDC) USB2_D‐ USB2_D+ USB2_DGND(ground pin) VT-M2M-TC 3.6 Operation Notice 3.6.1 Change SIM Card Push the small button on the left of SIM Card Holder, and install the SIM card to the holder. Then push the holder into the Slot. 3.6.2 Power Supply Please make sure using adapter in the accessory, or the power is not reversed when powered by other adapter. VT-M2M-TC Tips Waste Disposal It is recommended to disassemble the device before abandoning it in conformity with local regulations. Please ensure that the abandoned batteries are disposed according to local regulations on waste disposal. Do not throw batteries into fire (explosive) or put in common waste canister. Products or product packages with the sign of “explosive” should not be disposed like household waste but delivered to specialized electrical & electronic waste recycling/disposal center. Proper disposal of this sort of waste helps avoiding harm and adverse effect upon surroundings and people’s health. Please contact local organizations or recycling/disposal center for more recycling/disposal methods of related products. Comply with the following safety tips: Do not use in combustible and explosive environment Keep away from combustible and explosive environment for fear of danger. VT-M2M-TC Keep away from all energized circuits. Operators should not remove enclosure from the device. Only the group or person with factory certification is permitted to open the enclosure to adjust and replace the structure and components of the device. Do not change components unless the power cord is removed. In some cases, the device may still have residual voltage even if the power cord is removed. Therefore, it is a must to remove and fully discharge the device before contact so as to avoid injury. Unauthorized changes to this product or its components are prohibited. In the aim of avoiding accidents as far as possible, it is not allowed to replace the system or change components unless with permission and certification. Please contact the technical department of Vantron or local branches for help. Pay attention to caution signs. Caution signs in this manual remind of possible danger. Please comply with relevant safety tips below each sign. Meanwhile, you should strictly conform to all safety tips for operation environment. VT-M2M-TC Notice Considering that reasonable efforts have been made to assure accuracy of this manual, Vantron assumes no responsibility of possible missing contents and information, errors in contents, citations, examples, and source programs. Vantron reserves the right to make necessary changes to this manual without prior notice. No part of this manual may be reprinted or publicly released in forms of photocopy, tape, broadcast, e‐document, etc. FCC Warning This device complies with FCC class A Rules. Operation is subject to the Following conditions. This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. —Reorient or relocate the receiving antenna. —Consult the dealer or an experienced radio/TV technician for help. VT-M2M-TC Any modification to the product is not permitted unlessauthorized by Vantron.It’s not allowed to disassemble theproduct, it is not allowed to replace the system or change components unless with permission and certification. Please contact the technical support department of Vantron or local branches for help. IC statement This device complies with IC class A Rules. Disclaimer: Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. RF exposure warning This equipment must be installed and operated in accordance with provide instructions and the antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co‐located or operation in conjunction with any other antenna or transmitter. End‐users and installers must be provide with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. VT-M2M-TC Part II:Software Reference Introduction Thank you for choosing Vantron. It is our commitment to provide our valued customers with the embedded devices equipped with the state of the art technology and the best product services. Vantron’s M2M products are based on the most advanced ARM and Intel Atom processors and have low power consumption and high integration. The products are designed for applications of M2M in industrials, medicals, financial, retail, vehicle, and transportations etc. 1.1 About This Manual This manual is for user how to use sample programs in Linux system and how to use device in Linux system. We support three kinds of Linux system, and they have same sample programs, but each system has different, so when they have different we will specially note. This manual is protected by copyright. All rights are reserved by VT-M2M-TC Vantron. 1.2 Sample Programs Vantron supports many sample programs for TV-M2M-TC. You can test device modules through these sample programs, and can be the reference that you develop. client CAN data send program loopback CAN data receive program gpioctl GPIO test program power Power control for modules in the set serialdemo Serial testing and send AT Command program gps Get the gps information zigbee Zigbee testing program(zigbee module) Digixbee testing programs notices: The directory that sample programs isn’t fixed. The directory path of place is different under the different operating system, and concretely please according to 2 Starting The System. 1.3 Functionalities layout The below table lists VT-M2M-TC features. Chips or Interfaces Details VT-M2M-TC UART VT-M2M-TC has 4 UART ports: /dev/ttyS0 :DB9 COM Port (only Wind River is DEBUG SERIAL) /dev/ttyS1 :Green Terminal Pin 1,2 /dev/ttyS2 :GPS /dev/ttyS3 : ZIGBEE USB Host portx2 1xEthernet # ifconfig eth0 192.168.16.143 Audio MIC IN ALSA audio device #arecord–t wav test.wav Audio Out ALSA audio device #aplay test.wav Green Terminal 1 :TXD2 2 :RXD2 3 :GND 4 :CANH 5 :CANL 6 :GND 7 :EXTIO0 8 :EXTIO1 9 :EXTIO2 10 :EXTIO3 11 :EXTIO4 VT-M2M-TC EXTIO5 1.4 Linux OS Support The TV-M2M-TC supports the following Linux operating systems. Timesys* Fedora Remix 14 Ubuntu 12.04 Starting The System: The all Linux systems have the same sample programs. There different will be explained in each module. The systems version file: Linux System Timesys* Remix 14 Version file Fedora Ubuntu /home/vantron/version /home/vantron/version The systems user and password: Linux System Timesys* Remix 14 Ubuntu Fedora User name Passwd vantron vantron root vantron vantron vantron The sample programs path: VT-M2M-TC Linux System Path name Timesys* Fedora Remix 14 /home/vantron/demo Digi /home/vantron/xbee_driver/samples/posix/ Ubuntu /home/vantron/demo Digixbee: /home/vantron/xbee_driver/samples/posix/ bee: Parts of programs need root level, if you are not that please changing, example: $sudosu [sudo] password for vantron: Base Control The all programs in the sample programs path. 2.1 Power Control power [usb_wifi|can|gps|zigbee|3g] [on|off] wifi: Power control of usbWiFiModule can: Power control of CANModule gps: Power control of GPSModule zigbee: Power control of ZigBeeModule VT-M2M-TC 3g: Power control of 3GModule ex1: Turn on Power of ZigBee Module #./power zigbee on ex2: Turn off Power of ZigBee Module #./power zigbee off 2.2 Can Control a. Close device #ifconfig can0 down b. Configure CAN, set CAN’s baud rate to 1Mbps, or 100000(100kbps) #ip link set can0 type can bitrate 100000 #ifconfig can0 up c. Receive CAN data, it will receive CAN data which from other side #./loopback d. Send CAN data, it will send CAN package with ID of 0x02 #./client VT-M2M-TC 2.3 Gpio Control gpioctldirin: Set specified GPIO as input type dirout: Set specified GPIO as output get Read GPIO input level. Need set the GPIO as input first. set: Set GPIO as high level. Nee set the GPIO as output first. clear: Clear GPIO to low level, need set the GPIO as output first. gpionum: The GPIO be operated. 0 to 5 is EXTIO, 6 is zigbee burning signal, 9 is 3G internal power, 10 is intrnalpcie power, 11 is DIGI Xbee burning signal ex1: 2.4 a. Set EXTIO1 to high #./gpioctldirout1 #./gpioctl set 1 ex2: Read level of EXTIO1 #./gpioctldirin1 #./gpioctl get 1 Serial COM Control DB9 COM Port(Wind River is DEBUG serial): VT-M2M-TC Short Pin 2, 3 of DB9. #./serialdemo–d /dev/ttyS0 –b 9600 –r –w “hello” Can display some“hello” outputs b. COM port on green terminal Short Pin 1, 2 of green terminal #./serialdemo–d /dev/ttyS1 –b 9600 –r –w “hello” Can display some “hello” outputs 2.5 Audio Control a. Audio arecord #arecord–t wav test.wav b. Audio aplay #aplay test.wav 2.6 SD card Control a. Insert SD card ,then look over device: #fdisk–l b. mount SD card device: #mount /dev/mmcblk0 /mnt VT-M2M-TC 2.7 a. b. ADXL345 Control The test program path: /home/vantron/ADXL345_test/ Init ADXL345: #./adxinit Get the x,y,zdriction output: #./adxtest X: 233 Y: Z: 3ed VT-M2M-TC 3.1 WIFI Module BaseConfig The Timesys and ubuntu system can through GUI connecting WIFI network. The Wind River has not GUI, so must through command: Open WIFI network: >ifup wlan0 Close WIFI network: >ifdown wlan0 The WIFI config file: >cat /etc/sysconfig/network‐scripts/ifcfg‐wlan0 MODE=Managed DEVICE=wlan0 BOOTPROTO=dhcp ONBOOT=yes NM_CONTROLLED=no TYPE=Wireless ESSID=kkk #Change it into your essid, this is Public network VT-M2M-TC 3.2 OpenConfig a. Stop service network‐manager, Ubuntu service name is network‐manager, Fedora service name is NetworkManager, Wind River can skip. #service network‐manager stop b. Open wlan0 #ifconfig wlan0 up c. Set essid and key #iwconfig wlan0 essid“KKK” d. Look over the config #iwconfig wlan0 e. Get ip through DHCP #dhclient wlan0 f. Cancel DHCP #dhclient–r wlan0 g. Start networkmanager #service network‐namager start 3.3 WPA‐PSK/WPA2_PSK Config a. Stop service network‐manager, Ubuntu service name is VT-M2M-TC network‐manager, Fedora service name is NetworkManager, Wind River can skip. #service network‐manager stop b. Open wlan0 #ifconfig wlan0 up c. Set essid and passwd #wpa_passphrase ESSID PWD >wpa_supplicant.conf d. Connect the network #wpa_supplicant–B –iwlan0 –Dwext–c ./wpa_supplicant.conf e. Look over the config #iwconfig wlan0 f. Get ip through DHCP #dhclient wlan0 g. Cancel DHCP #dhclient–r wlan0 h. Start networkmanager #service network‐namager start VT-M2M-TC 4.1 3G Module BaseConfig The Timesys and ubuntu system can through GUI connecting 3G network. The Wind River doesn’t have GUI, so must through command. Looking over the device , HUAWEI em770w is ppp0, Telit HE910 is ppp1, Telit DE910 is ppp2. Sierra AirPrime SL8082 is ppp3. Open 3G network: >ifup ppp0 Close 3G network: >ifdown ppp0 The 3G config file: >cat /etc/sysconfig/network‐scripts/ifcfg‐ppp0 DEVICE=ppp0 NAME=test MODEMPORT=/dev/ttyUSB0 LINESPEED=115200 PAPNAME=test USERCTL=true ONBOOT=no VT-M2M-TC PERSIST=no DEFROUTE=yes PEERDNS=yes DEMAND=no IDLETIMEOUT=600 The other devices configuration /etc/sysconfig/network‐scripts/ifcfg‐ppp* . 4.2 file, see ScriptConfig 4.2.1 WCDMA Script a. The pppd scripts default in /etc/ppp/peers/. Create the “wcdma” script. >vim wcdma b. Add the following content in wcmda file, if you want to knowmore , please man pppd: #/etc/ppp/peers/wcdma #This is pppd script, used Huawei EM770W(Union) /dev/ttyUSB0 #Telit HE910 is /dev/ttyACM0 115200 crtscts modem debug VT-M2M-TC c. e. #nodetach usepeerdns defaultroute user "3gnet" 0.0.0.0:0.0.0.0 connect '/usr/sbin/chat ‐s ‐v /etc/ppp/peers/wcdma‐connect‐chat' Create the chat script >vim wcdma‐connect‐chat d. Add the following content in wcdma‐connect‐chat file: #/etc/ppp/peers/wcdma‐connect‐chat TIMEOUT 5 ABORT "DELAYED" ABORT "BUSY" ABORT "ERROR" ABORT "NO DIALTONE" ABORT "NO CARRIER" #"AT #'OK‐+++\c‐OK' ATH0 TIMEOUT 5 '' AT OK AT+CGDCONT=1,"IP","3gnet",,0,0 OK ATDT*99# CONNECT '' Start pppd program >pppd call wcdma ‐f VT-M2M-TC 5ZigBee Module 5.1DigiXbee Module Digixbee module sample programs are Digi supply, please looking into readme.txt. There has detail description. Here is basic operation. Open zigbee power (default open). #./power zigbee on Config and communication, more AT command. Please looking into Digixbee S2C user’s manual: The one device will set coordinator (default is route): #./at 9600 /dev/ttyS3 +++OK atce 1 atnd …….. (the route information , if return error fail) atdh 0 OK atdlffff OK add into network VT-M2M-TC atcn OK Hello world! This device is route: #./at 9600 /dev/ttyS3 +++OK atnd …….. (the route information , if return error fail) atdh 0 OK atdlffff OK atcn OK Hello world! add into network The AT command +++ into AT model atmy see network address atce 1 0 route , 1 coordinator atdh 0 set destination high address 0x00000000 atdlffff set destination low address 0x0000ffff atnd see route tables atcn exit AT model “Hello world !” is input world the other Xbee will get. VT-M2M-TC cmodule update: #./install_ebl XB24‐S2C_401E.ebl /dev/ttyS3 firmware update completed successfully VT-M2M-TC GPS Module 6.1 Get GPS Data Open /dev/ttyS2 , read GPS data #./gps 38400 /dev/ttyS2 6.2 6.2.1 GPS Data Format GPGGA Global Positioning System Fix Data Name Example Data Description Sentence Identifier $GPGGA Global Positioning System Fix Data Time 170834 17:08:34 Z Latitude 4124.8963, N 41d 24.8963' N or 41d 24' VT-M2M-TC 54" N Longitude 08151.6838, 81d 51.6838' W or 81d 51' 41" W Fix Quality: ‐ 0 = Invalid ‐ 1 = GPS fix ‐ 2 = DGPS fix Data is from a GPS fix Number of Satellites 05 5 Satellites are in view Horizontal Dilution of Precision (HDOP) 1.5 Relative accuracy of horizontal position Altitude 280.2, M 280.2 meters above mean sea level Height of geoid above WGS84 ellipsoid ‐34.0, M ‐34.0 meters Time since last DGPS update blank No last update DGPS reference station id blank No station id Checksum *75 Used by program to check for transmission errors ex:$GPGGA,hhmmss.ss,llll.ll,a,yyyyy.yy,a,x,xx,x.x,x.x,M,x.x,M,x.x,xxxx hhmmss.ss = UTC of position llll.ll = latitude of position a = N or S VT-M2M-TC yyyyy.yy = Longitude of position a = E or W x = GPS Quality indicator (0=no fix, 1=GPS fix, 2=Dif. GPS fix) xx = number of satellites in use x.x = horizontal dilution of precision x.x = Antenna altitude above mean‐sea‐level M = units of antenna altitude, meters x.x = Geoidal separation M = units of geoidal separation, meters x.x = Age of Differential GPS data (seconds) xxxx = Differential reference station ID 6.2.2 GPGSA GPS DOP and active satellites ex1: $GPGSA,A,3,,,,,,16,18,,22,24,,,3.6,2.1,2.2*3C ex2: $GPGSA,A,3,19,28,14,18,27,22,31,39,,,,,1.7,1.0,1.3*35 ex3: $GPGSA,<1>,<2>,<3>,<4>,,,,,<11>,<12>,<13>,<14>,<15>,<16>,<17>*< 18> = Mode: M=Manual, forced to operate in 2D or 3D A=Automatic, 3D/2D = Mode: VT-M2M-TC 1=Fix not available 2=2D 3=3D 3‐14 = IDs of SVs used in position fix (null for unused fields) 15 = PDOP 16 = HDOP 17 = VDOP 18 = cheaksum 6.2.3 GPGSV GPS Satellites in view ex: $GPGSV,3,1,11,03,03,111,00,04,15,270,00,06,01,010,00,13,06,292,00 *74 $GPGSV,3,2,11,14,25,170,00,16,57,208,39,18,67,296,40,19,40,246,00 *74 $GPGSV,3,3,11,22,42,067,42,24,14,311,43,27,05,244,00,,,,*4D $GPGSV,1,1,13,02,02,213,,03,‐3,000,,11,00,121,,14,13,172,05*67 = Total number of messages of this type in this cycle = Message number = Total number of SVs in view VT-M2M-TC = SV PRN number = Elevation in degrees, 90 maximum = Azimuth, degrees from true north, 000 to 359 = SNR, 00‐99 dB (null when not tracking) 8‐11 = Information about second SV, same as field 4‐7 12‐15= Information about third SV, same as field 4‐7 16‐19= Information about fourth SV, same as field 4‐7 6.2.4 GPRMC Recommended minimum specific GPS/Transit data ex1: $GPRMC,081836,A,3751.65,S,14507.36,E,000.0,360.0,130998,011.3,E *62 ex2: $GPRMC,225446,A,4916.45,N,12311.12,W,000.5,054.7,191194,020.3, E*68 225446 Time of fix 22:54:46 UTC Navigation receiver warning A = OK, V = warning 4916.45,N 12311.12,W 000.5 Latitude 49 deg. 16.45 min North Longitude 123 deg. 11.12 min West Speed over ground, Knots VT-M2M-TC 054.7 191194 020.3,E *68 Course Made Good, True Date of fix 19 November 1994 Magnetic variation 20.3 deg East mandatory checksum ex3: $GPRMC,220516,A,5133.82,N,00042.24,W,173.8,231.8,130694,004.2, W*70 3 4 6 7 10 11 12 220516 Time Stamp validity ‐ A‐ok, V‐invalid 3 5133.82 current Latitude 4 N North/South 5 00042.24 current Longitude 6 W East/West 7 173.8 Speed in knots 8 231.8 True course 9 130694 Date Stamp 10 004.2 Variation 11 W East/West 12 *70 checksum ex4: $GPRMC,hhmmss.ss,A,llll.ll,a,yyyyy.yy,a,x.x,x.x,ddmmyy,x.x,a*hh = UTC of position fix VT-M2M-TC = Data status (V=navigation receiver warning) = Latitude of fix = N or S = Longitude of fix = E or W = Speed over ground in knots = Track made good in degrees True = UT date 10 = Magnetic variation degrees (Easterly var. subtracts from true course) 11 = E or W 12 = Checksum 6.2.5 GPVTG Track Made Good and Ground Speed. ex1: $GPVTG,360.0,T,348.7,M,000.0,N,000.0,K*43 ex2: $GPVTG,054.7,T,034.4,M,005.5,N,010.2,K 054.7,T 034.4,M 005.5,N 010.2,K True track made good Magnetic track made good Ground speed, knots Ground speed, Kilometers per hour VT-M2M-TC ex3: $GPVTG,t,T,,,s.ss,N,s.ss,K*hh = Track made good = Fixed text 'T' indicates that track made good is relative to true north = not used = not used = Speed over ground in knots = Fixed text 'N' indicates that speed over ground in in knots = Speed over ground in kilometers/hour = Fixed text 'K' indicates that speed over ground is in kilometers/hour = Checksum The actual track made good and speed relative to the ground. $GPVTG,x.x,T,x.x,M,x.x,N,x.x,K x.x,T = Track, degrees True x.x,M = Track, degrees Magnetic x.x,N = Speed, knots x.x,K = Speed, Km/hr VT-M2M-TC 7Update System 7.1 Make USB boot Stick and Copy Image to USB stick Create PC condition: Create a bootable USB stick on Windows XP/ Win7, the first thing you need to do is insert a USB stick with at least 2GB of free space into your PC. Here use an USB installer tool to write the image ISO to USB stick. Please copy the file SW/tools/Universal‐USB‐Installer‐1.9.3.5.exe to your PC anywhere. USB stick making steps in detail as follows: Copy SW/image/xxx.iso image into your PC. Select the “Try Unlisted Linux ISO”from the dropdown list. VT-M2M-TC Click 'Browse' and select the image ISO file. VT-M2M-TC Choose the USB drive and click 'Create'. VT-M2M-TC 7.2 Update steps When the bootable USB stick create over, insert the USB stick into VT‐M2M‐TC. And connect a USB keyboard on the M2M‐TC. VT-M2M-TC Power ON the VT‐M2M‐TC, and step into BIOS by press the “Delete” key on the keyboard. In the BIOS, set the first boot option for boot up by USB stick. The user guidance of the BIOS is in the package of HW/700N16‐6Bxxxxxx_VT‐M2M‐TC_VM_xxx.zip. Select the first option “clonezilla live with img 700Pxxxxxx”. VT-M2M-TC When ask “Are you sure want to continue??” or “Let me ask you again, Are you sure you want to continue??” , please input ‘y’ all. VT-M2M-TC The system is updating. VT-M2M-TC When update over, the system will power off. Re‐power VT‐M2M‐TC, and step into the BIOS, and restore the first boot option to hard disk. VT-M2M-TC US Office: Vantron Technology, Inc. Address: 1292 Kifer Road #807, Sunnyvale, CA 94086 Tel: 510-304-7666 sales@vantrontech.com Email: China Office: Chengdu Vantron Technology,Ltd Address: 3rd floor, 3rd building, No.9, 3rd WuKe East Street, WuHou District, Chengdu, P.R. China 610045 Tel: 86-28-8512-3930/3931, 8515-7572/6320 Email: sales@vantrontech.com.cn
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : x.fu Create Date : 2014:01:22 15:14:28+08:00 Modify Date : 2014:01:23 10:54:05-08:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2 Metadata Date : 2014:01:23 10:54:05-08:00 Format : application/pdf Title : Microsoft Word - VT-M2M-TC User's Manual EN V1.8 20140116.docx Creator : x.fu Document ID : uuid:c5ae9729-918e-4757-aa51-cf150c2aff7c Instance ID : uuid:88abded7-3f49-42d1-a93a-9016b94868cb Page Count : 66EXIF Metadata provided by EXIF.tools