INSTALLATION INSTRUCTIONS
Instrucciones de instalación
Installationsanleitung
Instruções de Instalação

Istruzioni di installazione
Installatie-instructies
Instructions d´installation

IN-WALL ENCLOSURE
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description

PAC501

PAC501

Installation Instructions

DISCLAIMER
Milestone AV Technologies, and its affiliated corporations and
subsidiaries (collectively, "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a trademark of Milestone AV Technologies.
All rights reserved.

IMPORTANT WARNINGS AND
CAUTIONS!

WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.

CAUTION: This equipment must be installed and
assembled by qualified service personnel in accordance with
local building codes.

WARNING: Failure to provide adequate structural strength
for this accessory can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this accessory is attached
can support the combined weight of the box and all
equipment not to exceed 200 lbs (90.72 kg).

WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.

CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.

NOTES:
•
•
•

•

2

SUITABLE FOR USE IN OTHER ENVIRONMENTAL AIR SPACE IN ACCORDANCE WITH SECTION 300.22,
(C) OF THE NATIONAL ELECTRICAL CODE.
The maximum specified ambient temperature of the cabinet system is 40° - 120°F (4° - 49°).
Minimum spacings between the accessories and components and the housing for Information Technology
Communication Equipment shall be maintained for safe operation of the equipment when installed in
accordance with the National Electric Code, ANSI/NFPA 70-1999. Refer to communication equipment
manufacturer’s specifications for minimum spacings.
This Cabinet System is for use with ITE or Audio/Video equipment only.

Installation Instructions

PAC501

DIMENSIONS

2X

[657.2]
25.88
2X

2X

2X

[148.6]
5.85

[50.8]
2.00
2X

2X

[304.8]
12.00
2X

2X

[457.2]
18.00
2X

ELECTRICAL CUTOUT
DESIGNED TO FIT A SINGLE GANG
RACO 590, STEEL CITY CY ½ OR
SIMILAR STYLE ELECTRICAL BOX

[581]
22.88
[30.2]
R1.19

[17.5]
R.69
[97.9]
3.85

[711.2]
28.00

4X

[47.6]
1.88

2X

2X
[458.2]
18.04

[101.6]
4.00

[304.8]
12.00

[508]
20.00

GROUNDING SCREW CONNECTIONS

2X

[50.8]
2.00

[24.9]
.98

[762]
30.00

MEASUREMENTS IN: [MILLIMETERS]
INCHES

3

PAC501

Installation Instructions

LEGEND

4

Tighten Fastener

Pencil Mark

Apretar elemento de fijación

Marcar con lápiz

Befestigungsteil festziehen

Stiftmarkierung

Apertar fixador

Marcar com lápis

Serrare il fissaggio

Segno a matita

Bevestiging vastdraaien

Potloodmerkteken

Serrez les fixations

Marquage au crayon

Loosen Fastener

Drill Hole

Aflojar elemento de fijación

Perforar

Befestigungsteil lösen

Bohrloch

Desapertar fixador

Fazer furo

Allentare il fissaggio

Praticare un foro

Bevestiging losdraaien

Gat boren

Desserrez les fixations

Percez un trou

Phillips Screwdriver

Adjust

Destornillador Phillips

Ajustar

Kreuzschlitzschraubendreher

Einstellen

Chave de fendas Phillips

Ajustar

Cacciavite a stella

Regolare

Kruiskopschroevendraaier

Afstellen

Tournevis à pointe cruciforme

Ajuster

Open-Ended Wrench

Remove

Llave de boca

Quitar

Gabelschlüssel

Entfernen

Chave de bocas

Remover

Chiave a punte aperte

Rimuovere

Steeksleutel

Verwijderen

Clé à fourche

Retirez

By Hand

Optional

A mano

Opcional

Von Hand

Optional

Com a mão

Opcional

A mano

Opzionale

Met de hand

Optie

À la main

En option

Hex-Head Wrench

Security Wrench

Llave de cabeza hexagonal

Llave de seguridad

Sechskantschlüssel

Sicherheitsschlüssel

Chave de cabeça sextavada

Chave de segurança

Chiave esagonale

Chiave di sicurezza

Zeskantsleutel

Veiligheidssleutel

Clé à tête hexagonale

Clé de sécurité

Installation Instructions

PAC501

TOOLS REQUIRED FOR INSTALLATION

3/16"

PARTS
Grounding screw and washer
installed at factory

Earthing symbol IEC 60418 No. 5019
affixed adjacent to grounding terminal.

A (1)

B (1)

G (4)

C (8)
M7 x 40mm
D (4)
M7 x 50mm

F (10)
08 x 1/2"
E (1)
M7

5

PAC501

Installation Instructions

INSTALLATION
Wood Studs

WARNING: IMPROPER INSTALLATION CAN RESULT IN
DEATH OR SERIOUS PERSONAL INJURY! This accessory
should be installed by qualified personnel.

Site Preparation
Locate and Prepare Mounting Site
1.

Identify a suitable wall location for the in-wall enclosure.

IMPORTANT ! : The PAC-501 is designed for in-wall
installation spanning a minimum of three wood studs, 16"
on center. Installation of PAC-501 in 2x4 wall results in
nearly direct contact with vertical studs and back wall.
Inadequate space will remain for electrical wires/cables,
plumbing, ductwork, or insulation. Locate installation
accordingly.

(A)

WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surfaces is free
of electrical wires and cables before cutting, drilling, or
installing fasteners.

Figure 1
Frame Housing
The exposed portion of the center wood stud must be removed
and the resulting cavity completely framed with wood. The
following steps are suggested. The actual procedure is
dependent upon the specific installation.

WARNING: EXPLOSION AND FIRE HAZARD! CUTTING
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY! ALWAYS make certain
area behind mounting surfaces is free of gas, water, waste, or
any other plumbing before cutting, drilling, or installing
fasteners.
2.

Using a stud sensor, locate and mark studs.

3.

Center and level housing between marked studs.

4.

Using housing as a template, draw pencil line completely
around housing. (See Figure 1)

5.

Cut drywall on outside edge of line and remove.

WARNING: STRUCTURAL FAILURE HAZARD! FAILURE
TO TAKE ADEQUATE PRECAUTIONS CAN LEAD TO
DEATH OR SERIOUS INJURY! Ensure removal of center
stud will not cause unacceptable loss of structural strength.
Consult a qualified building contractor and applicable building
codes.
1.

Remove exposed portion of center wood stud flush with
upper and lower drywall edges.
Support
Blocks

Horizontal Framing
Top View

Wood
Screws
(5 places)
(Typical for each
support block)

Figure 2

6

Installation Instructions

PAC501

2.

Cut four 8" long support blocks out of 2x4 wood.

3.

Using three #10 x 2-1/2" countersunk wood screws (not
provided), attach each support block to the studs (See
Figure 2)

NOTE: Ensure screws are far enough from block end to

(A)

prevent interference with framing screws installed in
Step 5.
4.

If necessary, cut rectangular hole in horizontal framing to
accomodate the PAC-501 electrical box.

5.

Attach horizontal framing to each support block with two
#10 x 2-1/2" countersunk wood screws (not provided).
(See Figure 2)

In-Wall Enclosure Installation
1.

Install junction box (B) into the PAC-501 (A) using four
08 x 1/2" Phillips pan head tap screws (F). (See Figure 3)

Mounting
Holes

(A)

Figure 4
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR
CABLES CAN CAUSE DEATH OR SERIOUS
PERSONAL INJURY! ALWAYS make certain area behind
mounting surfaces is free of electrical wires and cables
before cutting, drilling, or installing fasteners.
5.

Drill four 3/16" diameter pilot holes in studs at side mounting
holes. (See Figure 5)

6

(D) x 4

(F) x 4
(B)

(G) x 4

Figure 3

2.

Connect electrical wiring.

3.

Route audio/visual cables into housing.

4.

Center PAC-501 in opening and insert into opening. Align
front of box with front face of wall. (See Figure 4)

5

xx4

Figure 5
6.

Attach the PAC-501 to side studs using four M7 x 50mm
Allen head connector screws (D) and mounting spacers (G)
using an M4 Allen head drill bit (E). (See Figure 5)

NOTE: The PAC-501 has 1/2" total clearance between the two
studs. The spacers allow side to side adjustment.

7

PAC501

Installation Instructions

USA/International

Chief Manufacturing, a division of
Milestone AV Technologies

Europe

Asia Pacific
8807-000073 Rev A
2008 Milestone AV Technologies
www.chiefmfg.com
10/08

A
P
F
A
P
F
A

8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
+31 (0)40 2668620
+31 (0)40 2668615
Room 24F, Block D, Lily YinDu International Building
LuoGang, BuJi Town, Shenzhen, CHINA.

P +86-755-8996 9226
F +86-755-8996 9217



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c320 44.284297, Sun Apr 15 2007 17:19:00
Create Date                     : 2008:10:28 15:59:34-06:00
Modify Date                     : 2008:10:28 16:02:20-05:00
Metadata Date                   : 2008:10:28 16:02:20-05:00
Producer                        : PDF-XChange 3.50.0099 (Windows Server 2003 x64)
Keywords                        : 8807-000073, Rev A, 10-08, PAC-501
Format                          : application/pdf
Title                           : PAC501 INSTALLATION INSTRUCTIONS
Creator                         : 
Subject                         : 8807-000073, Rev A, 10-08, PAC-501
Document ID                     : uuid:30b51993-d062-40f0-91ce-2a1d40073198
Instance ID                     : uuid:e3c3c655-8fb7-4dd2-aa5c-732339dcf138
Page Count                      : 8
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu