Chuango Security Technology WK8000 Wireless Keypad User Manual

Chuango Security Technology Corporation Wireless Keypad

User Manual

Download: Chuango Security Technology WK8000 Wireless Keypad User Manual
Mirror Download [FCC.gov]Chuango Security Technology WK8000 Wireless Keypad User Manual
Document ID3085567
Application IDDQh/LNVlfS4zO9kPLy68fw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize222.13kB (2776577 bits)
Date Submitted2016-08-03 00:00:00
Date Available2016-08-03 00:00:00
Creation Date2016-08-03 16:48:34
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2016-08-03 16:48:43
Document TitleUser Manual
Document CreatorAdobe InDesign CC 2014 (Windows)

M U LT I L I N G U A L
EN
FR
ES
PT
O P E R AT I O N M A N U A L
WK8000
Outdoor Keypad
2016 SMANOS HOLDING LTD. All Rights Reserved.
Printed in China
PA: WK8000-UM-ML-V1.0
Please read this manual carefully before using.
Please keep it properly for further reference.
EN
EN
Table of Contents
Foreword
Package List
Stay Mode
Emergency Call
Mute Mode
Product Overview
Notices and Maintenance
Preparation before Use
Usage Notices
Maintenance
Power on
Connect Keypad to Control Panel
Connect Keypad with RFID Tag
Installation
6-7
Settings
Enter Setup State
Delay Arm
Setting for SOS Function
Keyboard Tone
RFID Reader Setting
Direct Arm/Disarm by RFID Tag
Change User Code
Change Admin Code
Reset
10
11
12
13 - 14
15 - 16
17
18
19
Usage
Arm
Disarm
19 - 20
21 - 22
FAQ
Specifications
22
23
23
24
24
EN
EN
Foreword
Package List
Thank you for purchasing this wireless keypad. It is recommended
to install outside the entry door and users can achieve operations
such as arm, disarm, stay mode after inputting passcode.
RFID tag/card x 1
Screw driver x 1
Keypad x 1
Screw kit x 1
AAA 1.5V battery x 2
Manual x 1
Warranty Card x 1
EN
EN
Product Overview
LED Indicator
Positive and negative terminals for
batteryâ
Battery compartment
Tamper Switch
RFIDâ reader
RFID wake-up key
Arm
Stay mode
SOS
Disarm
â Max. 50 pcs are supported.
PR2600
â In case of low battery, the keypad sounds :"DiDi" for 6-7 times
afte rpressing Arm,Disarm or Home arm.
EN
EN
Change batteries
Slide the cover of the RFID reader, loose the screws of the four
corners, open the lid of the battery compartment, change the
batteries. Then cover all parts back.
Connect Keypad to Control Panel
Make sure the control panel is in connecting state, input user
codeâ or admin codeê on keypad, and then press any key of
. The connection succeeds after one beep.
User can remotely control the panel via keypad after connection.
(For detailed connection steps, please refer to the user manuals of panels.)
Note: If the control panel beeps three times after inputting the user code
or the admin code, that means the code is wrong, After 6 wrong inputs, the
keypad will be locked for 20 seconds. If the control panel beeps twice when
connecting, it means the keypad is already connected with the panel.
Note: Open the lid of the battery compartment will trigger tamper switch,
please dismiss the alarm by following the disarm instruction in page 21~22.
â The default user code is 1234.
ê The default admin code is 123456.
Preparation before Use
Power on
Connect Keypad with RFID Tag
1. Input [admin code + #] to wake up keypad.
First time to use
Just remove the insulating strip, the keypad will give off a long
beep and the LED light will be on until the beep stops.
EN
EN
2. Press [9], one beep is heard and the LED indicator is on. Keypad
enters learning state.
3. Tap the RFID tag on the reader RFID reader, the connection
succeeds after one beep and the LED indicator goes out.
If two beeps are heard, it indicates the RFID tag has been connected before.
Installation
Before using the keypad to control the system, you have to install
it to the doorframe or on the wall.
Step 1, slide the cover of the RFID reader gently, loose four small
screws, open the lid of the battery compartment.
Step 2, loose the big screw on the right of the tamper until the
back bracket is out.
Step 3, fix the bracket to the target place with the screws, please
notice the direction ( mark upwards).
Step 4, aim the keypad to the bracket, tighten it with screws,
gently lid the RFID reader cover at last.
To clear the connection of all RFID tags, input [admin code + #] to wake up the
keypad and then press down [9] for six seconds. All connected RFID tags will be
deleted.
Note: Opening the lid of the battery compartment will trigger tamper switch,
please disarm the alarm by following the disarm instruction in page 21~22.
EN
EN
Settings
Delay Arm
The keypad should enter setup state before all settings.
When the alarm system is armed, detectors will start working
immediately. If you are at home during the time, an alarm will be
triggered. After setting delay arm, press
on the keypad, the
arm signal will be sent to the control panel after the set time.
Enter Setup State
Input [admin code + #] to wake up keypad.
If the control panel and the keypad both set a delay time, the actual delay time is
the total of both times.
Delay Arm
Enter setup state, input:
2 delay time
Press [3] to enter setup state, the LED indicator is on.
Under setup state, if there is no operation within 10 seconds, the keypad will exit
setup state automatically. Or you can press [#] to exit.
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful.
Once the delay time is set, when you arm the keypad, it will beep once every
two seconds to remind you to leave. The reminding rhythm will speed up in the last
15 seconds. After the delay time, the control panel enters arm state.
Note: User can input digital 0-250 which refers to 0-250 seconds. Default
setting: 0, no delay.
10
EN
EN
Setting for SOS Function
Keyboard Tone
Direct SOS
Turn off Keyboard Tone
Enter setup state, input:
Enter setup state, input:
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful. After the setting, pressing the
SOS button for 3 seconds will trigger the alarm immediately.
Input Code for SOS
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful.
Turn on Keyboard Tone
Enter setup state, input:
Enter setup state, input:
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful.
After the setting, input the user code or the admin code, then
long press SOS button for 3 seconds, the keypad will send a
SOS signal to the control panel and the control panel will alarm
immediately.
Note: Default setting: 1, turn on keyboard tone.
Note: Default setting: 0, direct SOS.
11
12
EN
EN
RFID Reader Setting
User can enable or disable the function of arming/disarming by
RFID tag, or arming/disarming silently by RFID tag.
Disable RFID Reader
Enter setup state, input:
RFID Tag Silent Mode
By default, the control panel and siren beeps once when arming
the system by RFID tag or beeps twice when disarming the system.
If you want to turn off these beeps, just set the RFID Tag to silent
mode, that is ,when you arm or disarm the system by the RFID tag
via the keypad, The control panel and siren will not beep any more.
However, the keypad itself remains beeps.
Enter setup state, input:
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful. After the setting, the RFID
tags can not control the system anymore.
Enable RFID Reader
Enter setup state, input:
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful.
Note: Default setting: 1, enable RFID Reader. Users can arm or disarm the system
by using the RFID tag.
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful.
13
14
EN
EN
Direct Arm/Disarm by RFID Tag
When direct Arm/Disarm by RFID tag is enabled, users can directly
tap RFID tags to Arm/Disarm the system. However, the function
consumes power greatly. It is suggested to disable the function,
that is, set the keypad is in sleeping state. Users need to press the
[*] key before tapping RFID tags.
Disable Direct Arm/Disarm by RFID Tag
Enable Direct Arm/Disarm by RFID Tag
User can Arm/Disarm the system by RFID tag directly, which is
convenient but consumes more power.
Enter setup state, input:
Enter setup state, input:
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful. After the setting, you need to
press the [*] before arming/disarming the system.
15
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful.
Note: Default setting: 1, enable the function of direct Arm/Disarm by RFID tag.
16
EN
EN
Change User Code
Change Admin Code
Using user code can wake up keypad, or send Arm, Disarm, Stay
Mode commands to the control panel.
Using admin code can wake up keypad, send Arm, Disarm, Stay
Mode commands to the control panel, and also change keypad
settings.
Change User Code
For your safety, it is suggested to change both user codes and
admin codes after your purchase.
Enter setup state, input:
8 new user code
Change Admin Code
Enter setup state, input:
9 new admin code
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful.
Note: User code is 4 digits; default code is “1234”.
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful.
Note: Admin code is 6 digits; default code is “123456”.
17
18
EN
EN
Reset
After reset,both user code and admin code and other settings will
be restored to default but the connected RFID tags are still valid.
When the alarm panel receives the signal, the siren will beep once.
The alarm system enters armed state.
Enter setup state, input:
When one beep is heard and the LED indicator keeps on for
10 seconds, the setup is successful.
Usage
The keypad can be used as a remote control. User code or admin
code should be input before the operation of Arm, Disarm, Stay
Mode, and Mute Mode.
Using RFID Tag to Arm
If direct arm is enabled,just tap the RFID tag twice within 3
seconds on the keypad to arm the system.
If direct arm is disabled,user needs to press [*]to wake up the
keypad and then tap RFID tag twice within 3 seconds on the
keypad to arm the system.
Arm
Using keypad to arm
key, the LED
Input user code or admin code, and press
indicator flashes once and the keypad beeps once and sends arm
signal to the control panel.
19
20
EN
EN
Disarm
Using RFID Tag to Disarm
Users can disarm alarm system by pressing keypad or by using
RFID tags.
If direct disarm by RFID tag is disabled, user needs to press [*] to
wake up the keypad and then tap the RFID tag on reader to disarm
the system.
Using Keypad to Disarm
Input user code or admin code, and press
key, the LED
indicator flashes once and the keypad beeps once and sends
disarm signal to the control panel.
When the alarm panel receives the signal, the siren will beep twice
and the Disarm indicator will light on, the alarm system enters
disarmed state. In this state, the sensors being triggered will not
cause an alarm.
If direct disarm by RFID tag is enabled, user is able to tap the RFID
tag on the reader to disarm the system.
Stay Mode
Input user code or admin code, and press
key, the LED
indicator flashes once and the keypad beeps once and sends stay
mode signal to the control panel.
When the alarm panel receives the signal, the siren will beep once,
the alarm system enters stay mode state.
All the sensors in other zones are armed to prevent the intruder
except that the motion detector in Home Mode Zone is disarmed,
so people can move freely at home.
21
22
EN
EN
Emergency Call
If the SOS function is set to direct SOS, user just holds the
long blank key in the bottom for 3 seconds, the LED indicator
flashes once, keypad beeps once, and the control panel alarms
immediately.
Notices and Maintenance
In order to avoid any harm to the users or others during usage
and prolong the usage life, please abide by the following notices.
Usage Notices
General instruction
The keypad should be connected to control panel before use.
The power supply of keypad will probably impact on the transmitting distance of
wireless signal.
The keypad can be powered by 2 pcs of AAA batteries.
If the SOS function is set to input code for SOS, input user code or
admin code before holding the long blank key in the bottom for
3 seconds to send an alarm.
Mute Mode
Mute mode means to arm or disarm the alarm system mutely.
Input user code or admin code, and hold any key of
for 2 seconds, until the keypad beeps once and sends
corresponding command to the control panel.
When the alarm panel receives the
signal, the LED indicator lights on
or off, but the siren does not beep.
The keypad is compatible with any of our alarm system in the same frequency.
Please remove the battery insulating strip before use.
Do not press the SOS button if there’s no emergency to avoid disturbing the
neighborhood.
Check the keypad regularly to ensure the system works properly in case of
emergency.
The case of keypad is made of ABS. Please keep it away from strong light to
ensure the lifetime.
Forbiddance
The keypad is non explosion-proof. Please keep it away from fire, flame sources.
Install the keypad away from objects such as heater, air conditioner, microwave
oven etc. that produces heat or electric-magnetic.
Forbiddance of decomposition
Take the keypad for disposal of recycling according to the local regulation.
Do not take apart the product if you are not a professional technician.
Maintenance
You can get most dust or fingerprint off with a dry, soft cloth or
tissue. If there is dirt on the keypad, please wipe the surface by
a soft cloth with a little dilute alkaline detergent and then wipe
again with a dry cloth.
23
24
EN
EN
FAQ
Problem
No response
from keypad
Keypad
cannot
connect to
control panel
No response
from the
control panel
by operating
on keypad
Cannot arm/
disarm by
RFID Tags
Keypad
cannot be
programmed
Keypad
cannot be
armed,
disarmed and
in stay mode
25
Specifications
Cause
Solution
Low battery
Please change the battery
Keypad is locked
by inputting wrong
passcode continually
more than 6 times
Keypad will be unlocked after
non-operation for 20 seconds
The positive and
negative terminals are
reversed
No response from
alarm panel
Alarm panel beeps
twice
Keypad is not learned
to control panel
Distance between
keypad and control
panel is too far
The RFID tags are not
learned to keypad
RFID reader is
disabled.
Direct disarm by RFID
tag is disabled.
Follow the right terminal
direction and insert the battery
again
Make sure the alarm panel is
powered on
Make sure the alarm panel enters
learning state
Keypad has been learned
Please connect the keypad to the
control panel by following the
manual instruction
Please move the keypad in a
proper distance where control
panel can receive the signal of
keypad
It’s recommended to buy signal
repeater to extend the distance
Please connect the RFID tag to
control panel by following the
manual instruction
Enter setup state and activate the
RFID reader.
Disarm after pressing [*] key
Keypad is not waked
up
Please input [admin code+#] to
wake up the keypad
Haven't input user
code or admin code
before operation
Please input the user code or
admin code before operation
Keypad doesn’t enter
setup state
Please input [admin code+#],
and press [3] to enter setup state
Product Name:
Outdoor Keypad
Model No.:
WK8000
Power Supply:
2 pcs of AAA batteries
Static Current:
<20μA (powered by batteries)
Transmitting Current:
<22mA
RFID Tags Supported:
50pcs
Transmitting Distance:
<80m ( in open area)
Radio Frequency:
915MHz and 125kHz
Housing Material:
ABS plastic
Waterproof Rating:
IP55
Operating Condition:
Temperature: -20°C~+55°C
Relative Humidity: <80% (non-condensing)
Dimensions:
157.5 x 70 x 20.7 mm
Output Power:
No more than 50dBuV at 3m(125KHz)
26

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Count                      : 15
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:a46dfb5c-a287-4481-9b06-c02104fec22b
Modify Date                     : 2016:08:03 16:48:43+08:00
Create Date                     : 2016:08:03 16:48:34+08:00
Metadata Date                   : 2016:08:03 16:48:43+08:00
Document ID                     : uuid:a7a3d028-5b23-4ed1-b73d-29aa74779f56
Format                          : application/pdf
Tagged PDF                      : Yes
Creator                         : Adobe InDesign CC 2014 (Windows)
Producer                        : Adobe PDF Library 11.0
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RJYWK8000

Navigation menu