Chung s Electronic CHUNGS-05-004 Wireless Weather Station (Receiver) User Manual D 2005 D 1 2005PD 2 MANUAL 8xx

Chung's Electronic Co. Ltd. Wireless Weather Station (Receiver) D 2005 D 1 2005PD 2 MANUAL 8xx

User Manual

Download: Chung s Electronic CHUNGS-05-004 Wireless Weather Station (Receiver) User Manual D  2005 D 1 2005PD 2 MANUAL 8xx
Mirror Download [FCC.gov]Chung s Electronic CHUNGS-05-004 Wireless Weather Station (Receiver) User Manual D  2005 D 1 2005PD 2 MANUAL 8xx
Document ID576292
Application IDt/Q8ttNIhVM9CxtcyqSxbw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize14.25kB (178187 bits)
Date Submitted2005-08-30 00:00:00
Date Available2005-08-30 00:00:00
Creation Date2005-05-16 21:03:38
Producing SoftwareAcrobat PDFWriter 5.0 for Windows NT
Document Lastmod2005-05-28 12:25:59
Document TitleD:\2005-D~1\2005PD~2\MANUAL\8xx
Document CreatorAdobe PageMaker 7.0 - [D:\2005-D~1\2005PD~2\MANUAL\8xx\C-8154\C-8154-PD050316M.pmd]
Document Author: xy

WIRELESS WEATHER STATION
C-8154
USER’S INSTRUCTIONS
P17815400030
p. 1
The multifunctional weather station is equipped with many
functions providing thorough weather information to you.
The receiver unit has a clear, easy-to-read display that
shows weather forecast, indoor temperature, pressure,
moon phase, time and date, as well as the temperature
measured and transmitted by the sensor. It is able to receive and display readings from up to 3 remote sensors.
The receiver unit retains the minimum and maximum
temperatures and relative humidity readings measured at
various locations. The 433 MHz technology means no wire
installation is required and you can place the sensors
anywhere you like.
With radio controlled function, the current time and date
a r e automatically synchronized with the time signal
transmitted from Frankfurt Germany (DCF77) / UK (MSF) /
US (WWVB). The signal can cover a distance of about 1500
km from the related transmitter.
p. 25
p. 2
FCC Remarks:
MAIN FEATURES:
WEATHTER STATION:
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause
undesired operation.
1 2 34 5 6
11
10
Warning: Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
l Reorient or relocate the receiving antenna.
l Increase the separation between the equipment and receiver.
l Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
l Consult the dealer or an experienced radio/TV technician for
help.
p. 3
p. 24
0.1 ºC / 1ºF (above 0 ºC)
1 ºC / ºF (below 0 ºC)
Temperature resolution:
RF transmission frequency:
No of remote unit:
RF transmission range:
Temperature sensing cycle:
Pressure measuring range:
Pressure sampling cycle:
Moon phase scanner range:
Radio controlled signal:
Power:
Main unit:
433MHz
up to 3 units
Maximum 30 meters
around 60 ~ 64
seconds
800mb to 1050mb
15 minutes
From 2000 to 2050
DCF77, MSF, WWVB
4.5 V, use 3 x AA 1.5V
alkaline battery
3 V, use 2 x AAA 1.5V
alkaline battery
Remote sensor:
Weight
Main unit:
Remote sensor:
Dimension
Main unit:
Remote sensor:
650gm
53gm
306x224x24mm
65(W)x93(H)x 27(D)mm
1. TIME:
- Press it once to view the year.
- Press and hold it for 2 seconds to enter the time setting
mode.
2. ALARM:
- Press it to switch to alarm and temperature alarm.
- In alarm mode, press and hold it for 2 seconds to enter
the alarm and pre-alarm setting mode.
3. UP:
- In normal time mode, press it to choose between
channel (1), (2) and (3).
- In setting mode, press it to increase the setting value.
- In alarm mode, press it to turn on/off alarm and snooze.
4. DOWN:
- Press and hold it for 3 seconds, release, then press it
to change the weather indicator.
- In alarm mode, press it to turn on/off alarm and snooze.
5. HISTORY:
- Check the past 24 hours pressure records.
6. MAX/MIN :
- Press it once to check max./ min. temperature record.
- Press and hold it for 3 seconds to delete the max. and
min. record.
7.
p. 23
RESET:
- Press it to set all values to factory value.
p. 4
- In case of mal-function, the unit may be required to reset.
8. ºC / ºF:
- Switch between ºC / ºF.
9.
mb/hPa . inHg:
- Switch between mb/hPa or inHg.
Fix the separate wall-mounting stand on the wall by screws.
Push the stand of the clock upward, hang it on the
wall-mounting stand by its recessed holes.
For the transmitter, fix the wall-mount holder on the wall or
simply place it on the table.
10. TABLE STAND
- use to stand on desktop
11. WALL-MOUNTING HOLE:
- Use to support the main unit on wall.
12. WEATHER FORECAST WINDOW:
- Displays the weather forecast indicator.
13. ATMOSPHERE PRESSURE WINDOW:
- Displays the current atmospheric pressure data and
indicates the last 24 hours pressure history.
14. CALENDAR WINDOW:
- Displays the date, year, day of the week and moon
phase.
SPECIFICATIONS
MAIN UNIT
Indoor temperature measuring range:
Recommended operating range:
Temperature resolution:
-5 ºC to +50 ºC
0 ºC to +45 ºC
0.1 ºC / 1ºF (above 0 ºC)
1 ºC / ºF (below 0 ºC)
REMOTE SENSOR
15. CLOCK WINDOW :
- Displays the time radio controlled signal.
p. 5
Temperature measuring range:
Recommended operating range:
p. 22
-20 ºC to +60 ºC
-20 ºC to +55 ºC
LOW BATTERY INDICATOR
When the battery does not have enough power to operate
the unit, the low battery indicator will appear to remind you
to replace with new batteries.
Transmitter’s low battery indicator
( shows on transmitter )
Transmitter’s low battery indicator
( shows on the main unit)
16. INDOOR TEMPERATURE AND HUMIDITY WINDOW:
- Shows the indoor temperature-trend, current temperature,
or the maximum or minimum recorded temperature.
17. OUTDOOR TEMPERATURE :
- Shows the outdoor temperature-trend, current temperature,
or the maximum or minimum recorded temperature.
TRANSMITTER:
CH
Receiver’s low battery indicator
NOTE:
Attention should be drawn to the environmental aspects
of battery disposal
USING THE TABLE STAND OR WALL MOUNTING
The receiver has both desk-top and wall-mounting structure.
p. 21
p. 6
1. LED indicator:
- Flashes when the remote unit transmits a reading.
2.
3.
LCD:
- Displays the current temperature monitored by the
remote unit .
Channel slide switch:
- Assign the transmitter to Channel 1, Channel 2 or
Channel 3.
4. ºC / ºF:
- Switches between ºC / ºF.
5. RESET:
- Return all values to default value.
6. Battery compartment:
- Accommodates 2 AAA size batteries.
7. Battery door
8. Wall mount holder:
- Supports the transmitter in wall mounting.
9. Folding table stand
p. 7
Each press on the button will go back by an hour. The
recorded atmospheric values for the past 24 hours are
displayed in the atmospheric pressure window.
ABOUT THE MOON PHASE
The unit has 8 different moon phases. It will change
according to the lunar calendar.
1.
2.
3.
4.
5.
6.
7.
8.
New moon
Waxing crescent
First quarter
Waxing Gibbous
Full moon
Waning Gibbous
Last quarter
Waning crescent
p. 20
2. The weather forecast is meant for next 12 to 24 hours. It
may not necessarily reflect the current situation.
3. The “Sunny” icon, when applies to nighttime, implies clear
weather.
Slightly cloudy
Cloudy
TENDENCY
TENDENCY
Rainy
Storm
TENDENCY
Sunny
TENDENCY
BEFORE YOU BEGIN
TRANSMITTER:
1. Remove the removable stand, unscrew the screws of the
back cover and lift the cover off.
2. Insert 2 x AAA batteries into the battery compartment. Be
sure to insert them the right way round (see polarity
information +/- in the battery compartment).
3. The receiver can receive humidity and temperature data
from up to 3 transmitters. Assign the channel to each
transmitter, Channel 1, 2 or 3 respectively by sliding the
switch besides the battery compartment.
4. Press the reset key of the transmitter individually by a pin
to confirm the channel setting.
5. Select the temperature unit by sliding the ºC / ºF switch
besides the battery compartment.
6. Re-fix the battery door, and secure its screws evenly
and diagonally.
PAST 24 HOURS PRESSURE RECORDS
NOTE:
The current and historical barometric pressure is shown
on the atmospheric pressure window. The atmospheric
pressure can be displayed in mb/hPa or inHg by selecting
the atmospheric pressure slide switch at the case back.
Checking the pressure history for a particular hour durthe
p. 19
1. Once the channel is assigned to a transmitter, you can
only change it by removing the batteries or resetting the
unit.
2. Avoid placing the transmitter in direct sunlight, rain or
snow.
p. 8
WEATHER STATION:
WEATHER TREND
1. Remove the battery door and insert 3 x AA batteries into
the battery compartment. Make sure you insert the
batteries the right way round (see polarity information +/in the battery compartment).
2. Close the battery compartment.
3. Press reset button to re-start the clock and it will
synchronise the channels of the transmitter automatically.
The temperature-trend, and pressure-trend indicators show
the trends of changes for the last few minutes. Arrows indicate a rising, steady or falling trend.
Arrow indicator
Temperature trend
Rising
Steady
Falling
Rising
Steady
Falling
Arrow indicator
NOTE:
Pressure trend
1. If extra transmitter is added in the future, press reset
button to re-start the clock and synchronise the channel
once again.
2. T h e b u i l d i n g m a t e r i a l a n d t h e p o s i t i o n o f t h e
receiver and transmitter affect the effective range. So
try various locations will help to obtain the best result.
3. Place the units away from metal objects and electrical
appliances to minimize the interference. Position the
r e c e i v e r a n d t h e transmitter within effective
transmission range: 30 meters in usual circumstances.
SETTING WEATHER INDICATOR
Important: To get a better result of weather forecast
p. 9
WEATHER FORECAST
The built-in barometer can notice atmospheric pressure
changes. Based on the data collected, it can predict the
weather condition in the forthcoming 12-24 hours. The
effective covers area ranges from 30 to 50 km.
NOTE:
1. The accuracy of a general pressure-based weather
forecast is about 70 to 75% , and therefore, cannot be
held responsible for any inconvenience caused by an
inaccurate data.
p. 18
1. Press MAX/MIN key to check Maximum temperature records.
Press it twice to check the Minimum records. Press it
thrice to exit.
2. Press and hold MAX/MIN key for 3 seconds to delete the
records.
MAX. Temperature record
indicator, please set the weather forecast icon
according to the current weather condition.
1. In normal time mode, press and hold DOWN key for 3
seconds, weather indicator flashing.
2. Press DOWN key to change the weather indicator in this
order:
Slightly cloudy - Cloudy - Rainy - Storm - Sunny
3. Choose the suitable indicator according to the current
weather.
4. Press TIME key to return to the normal mode or let it
automatically return to normal mode after 30 seconds
without pressing any keys.
Slightly cloudy
Cloudy
MIN. Temperature record
TENDENCY
TENDENCY
Rainy
Storm
TENDENCY
p. 17
Sunny
TENDENCY
p. 10
NOTE:
1. Do not set the weather indicator when it is raining.
Raining will give unstable data.
2. Do not set the weather indicator in night time.
RECEPTION OF RADIO CONTROLLED TIME SIGNAL
The time and date are radio-controlled. The current time
and date are automatically synchronized with the time
signal transmitted from Frankfurt, Germany (DCF77), UK/
(MSF) / US (WWVB) provided the device is within about of
1500 km range of the transmitter.
When used for the first time (after inserting the batteries or
pressing RESET), the clock starts receiving time signals
and the reception display flashes.
SIGNAL STRENGTH INDICATOR
HOW TO READ INDOOR AND OUTDOOR
TEMPERATURE RECORDS
Change the temperature unit by sliding ºC / ºF slide switch
to ºC for Centigrade or ºF for Fahrenheit.
If the readings go above or below the specified range, the
receiver and transmitter will keep show the last record within
the operation range.
NOTE:
1. If no signals are received or the transmission is
interfered with, “---” appears in the display.
2. Locate the clock in other position and make sure the
transmission is within the effective range of 30 meters
approx.
3. After several trials but in vain, please reset the clock
thoroughly. Try out where your multifunctional alarm
clock receives the signals best.
The signal indicator displays signal strength in 3 levels.
Wave segment flashing means time signals are being
received. The signal quality could be classified into
threetypes:
CHECKING AND DELETING MAX./MIN.
TEMPERATURE REOCRDS
p. 11
p. 16
SETTING THE TEMPERATURE ALARM
NOTE:
Use this function to be woken up at a determined period of
time earlier (1-30 minutes), if one of the transmitter’s
temperatures is below -1ºC.
1. In normal time mode, press ALARM key twice to enter
pre-alarm mode, press UP or DOWN key to turn
pre-alarm on.
2. Press and hold the ALARM key for 2 seconds, pre-alarm
time flashing, press UP or DOWN key to change its value.
1. Everyday the unit will automatically search for the time
signal at 2:00, 8:00, 14:00 and 20:00.
2. Always place the unit away from interfering sources such
as TV set, computer, etc.
3. Avoid placing the unit on or next to metal plate.
4. Closed area such as airport, basement, tower block or
factory is not recommended.
5. Do not start reception on a moving article such as
vehicle or train.
NOTE:
To activate pre-alarm function, ALARM must be on.
SELECT THE TIME ZONE (FOR WWVB VERSION ONLY)
Temperature alarm ON
Pre-alarm mode
Pre-alarm 15 minutes
AM
PRE- AL
PRE- AL
VIEWING THE CHANNEL
The default channel is channel 1. In normal time mode,
press UP key to view the channel from 1 to 3.
p. 15
The default time Zone is PACIFIC Zone, if your location is out
of Pacific, set the time zone as the following:
In normal time mode, press DOWN button to change it:
P=Pacific M=Mountain C=Central E=Eastern
MANUAL TIME SETTING
If you are out of the reach of the Radio Controlled Tranmsitter
or if the reception is not reachable, the time can be set
p. 12
manually. As soon as the transmitter is received again, the
clock will automatically synchronise with the received time.
1. In normal time mode, press and hold TIME key for 2
seconds, hour flashing, press UP or DOWN key to
change its value.
2. Press TIME key again, minute flashing, press UP or DOWN
key to change its value.
3. Repeat the above operation to set the time in this order:
Hour - Minute - Second - 12/24 hour - Year - Month - Date
- Day language.
4. 5 languages weekday setting sequence is : English-GB /
French-FR / German-DE / Spanish-ES / Italian-IT.
5. After setting completed, press TIME key to exit setting
mode, or let it exit automatically in 30 seconds without
pressing any key.
English
Germany
SON
French
DIM
MON
DIE
MIT
DON
LUN
FRE
SAM
VEN
MAR
MER
JEU
SAM
Spanish
DOM
LUN
MAR
MIE
JUE
VIE
SAB
Italian
DOM
LUN
MAR
MER
GIO
VEN
SAB
alarm mode. Press UP or DOWN key once, alarm is on
with the bell indicator displayed. Press UP or DOWN key
again to turn on SNOOZE with Zz displayed. Press UP or
DOWN key to turn off ALARM and SNOOZE.
2. In normal mode or alarm mode, press and hold ALARM
key for 2 seconds, hour flashing. Press UP or DOWN key
to set the value. Repeat the same operation to set the
alarm minute.
3. After setting completed, press ALARM key to return to
normal mode, or let it exit automatically 30 seconds later
without pressing any key.
NOTE:
1. The alarm will automatically turn on when setting the
alarm time.
2. The EL backlight will keep on for 5 seconds when the
alarm is sounding.
3. Once the snooze is turn on, the 4-step crescendo
alarm will sound 4 times in 5-minute interval. The alarm
duration is 120 seconds.
Alarm OFF
AM
Alarm ON
AM
AM
ALARM AND SNOOZE SETTING
Zz
1. In normal time mode, press ALARM key once to enter the
p. 13
Alarm and Snooze ON
p.14

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat PDFWriter 5.0 for Windows NT
Create Date                     : 2005:05:16 21:03:38Z
Modify Date                     : 2005:05:28 12:25:59+08:00
Metadata Date                   : 2005:05:28 12:25:59+08:00
Creator Tool                    : Adobe PageMaker 7.0 - [D:\2005-D~1\2005PD~2\MANUAL\8xx\C-8154\C-8154-PD050316M.pmd]
Format                          : application/pdf
Title                           : D:\2005-D~1\2005PD~2\MANUAL\8xx
Creator                         : xy
Document ID                     : uuid:fb6573db-22c4-4fe8-ae83-e45141fc1227
Instance ID                     : uuid:9515818d-ca3b-4008-9f5f-d7012437a4e4
Page Count                      : 14
Author                          : xy
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OQH-CHUNGS-05-004

Navigation menu