Chungear Co CE10010 Ceiling Fan Remote Controller(Transmitter) User Manual TR125B MR77A AC120V

Chungear Industrial Co Ltd Ceiling Fan Remote Controller(Transmitter) TR125B MR77A AC120V

Users Manual

Download: Chungear Co CE10010 Ceiling Fan Remote Controller(Transmitter) User Manual TR125B  MR77A AC120V
Mirror Download [FCC.gov]Chungear Co CE10010 Ceiling Fan Remote Controller(Transmitter) User Manual TR125B  MR77A AC120V
Document ID1653451
Application IDlaZiV3PTtobQFCsW/47WKg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.92kB (98967 bits)
Date Submitted2012-03-12 00:00:00
Date Available2012-03-12 00:00:00
Creation Date2012-02-22 11:38:24
Producing SoftwareAcrobat Distiller 8.3.1 (Windows)
Document Lastmod2012-03-07 17:09:21
Document TitleMicrosoft Word - TR125B+ MR77A AC120V.doc
Document CreatorPScript5.dll Version 5.2
Document Author: user

CEILING FAN REMOTE CONTROLLER
OPERATION AND INSTALLATION INSTRUCTIONS
(Please keep this instruction pamphlet.)
IMPORTANT
YOU MUST SET CEILING FAN MANUAL SWITCH TO HIGH SPEED AND LIGHT
KIT (IF ANY) TO ON POSITION BEFORE OPERATING REMOTE CONTROL.
IMPORTANT POINTS TO REMEMBER:
1.
2.
3.
Read and save these instructions.
Please note that all fixed wiring appliances should be installed by a qualified electrician.
The supply to the remote control receiver should be connected through a mains switch, i.e.
existing wall switch.
4. Disconnect from power supply at wall switch before working on remote control receiver or
ceiling fan.
5. Install receiver into the ceiling fan canopy of the fan to ensure proper protection.
6. This unit is to be used for the control of ceiling fan and in an AC120V 60Hz power supply only.
7. Do not install in damp locations or immerse in water. (For indoor use only.)
8. Do not pull on or cut leads shorter.
9. Do not drop or bump the unit.
10. PLEASE NOTE: The battery will weaken with age and should be replaced before leaking
takes place as this will damage the transmitter. Dispose of used battery properly, and keep
the battery out of reach of children.
11. CAUTION: To reduce the risk of fire or injury, do not use this product in conjunction with any
variable (rheostat) wall control.
INSTALLATION INSTRUCTIONS
CAUTION: INCORRECT WIRE CONNECTION WOULD DAMAGE THIS RECEIVER.
1. Ceiling fan must be set at HIGH speed and light kit (If any) at ON position by pressing the
“Light Switch” after installation.
2. Once the connection has been made, the receiver inserts into motor control case.
WHITE(FOR LIGHT)
BLUE(FOR LIGHT)
LEARNING PROCESS
1. This unit finished learning process inside manufactory, if replace transmitter or receiver, user
need to redo learning process before using this unit.
2. Open battery cover (with battery, DC9V 1pcs, installed) and use a ball pen to set Code switch
up or down (Fig. 1). Then turn ceiling fan power on, press transmitter “FAN OFF” key over
5seconds, down light will be flash twice, which indicate that learning process finished. Learning
effect distance is same with remote’s. Please note that must press the “FAN OFF” key within
30sensonds after power on. If just replace batteries, no need to re-learn.
3. Please note that the transmitter can learn in multiple receiver, when doing learning process
please make sure not learn in other receiver. Suggest to separate power switches of fans in 2
meter range.
LIGHT FUNCTION SELECT SWITCH
1. If installed energy light onto ceiling fan down light, please slide the “down light function select
switch” to “O” position (Fig. 2). If installed tungsten light onto ceiling fan, please slide the “down
light function select switch” to “D” position.
CODE SWITCH
Fig. 1
DOWN LIGHT FUNCTION
SELECT SWITCH
Fig. 2
TRANSMITTER
FUNCTIONS OF TRANSMITTER
LIGHT
FAN OFF
HI
MED
LOW
REVERSE
: ON/OFF- Press and release immediately to turn on or off
the light.
DIMMER-Press and hold to dim or brighten light
to the desired level and release.
(Tungsten only and down light function select
switch” to “D” position.)
: Turn off the ceiling fan.
:Turn on the fan at high speed
:Turn on the fan at medium speed
: Turn on the fan at low speed
: Press and release immediately to set
fan wind direction up or down.
Installation of
Transmitter Wall
Mount Holder with
two screws.
MODEL:TR125B
FEDERAL COMMUNICATIONS COMMISSION
INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.
CAUTION:
To assure continued FCC compliance:
Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to
operate the equipment.
FCC ID:KUJCE10010
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 8.3.1 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2012:03:07 17:09:21+08:00
Create Date                     : 2012:02:22 11:38:24+08:00
Metadata Date                   : 2012:03:07 17:09:21+08:00
Format                          : application/pdf
Title                           : Microsoft Word - TR125B+ MR77A AC120V.doc
Creator                         : user
Document ID                     : uuid:cd6f95ff-ba8b-4961-8969-e9cf4ecdc4fd
Instance ID                     : uuid:3b97756c-4b55-4471-9531-40c4ca7174bd
Page Count                      : 3
Author                          : user
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KUJCE10010

Navigation menu