Cilag Z ONE TOUCH Verio Flex / Blood Glucose Monitoring System User Manual
Cilag GmbH International ONE TOUCH Verio Flex / Blood Glucose Monitoring System
Cilag >
Contents
- 1. User Manual
- 2. User Manual Statements
User Manual
C4 Yellow = 5mm margin, Red = 10mm margin nd in 51 0k ev ie Contents covered by one or more of the following U.S. patents: 6,179,979, 6,193,873, 6,284,125, 6,716,577, 6,749,887, 6,797,150, 6,863,801, 6,872,298, 7,045,046, 7,498,132, 7,846,312, 8,449,740, 8,529,751 and 8,398,664. Use of the monitoring device included herein is protected under one or more of the following U.S. patents: 6,413,410, 6,890,421, 8,163,162, 7,749,371, 8,449,740 and 8,529,751. Purchase of this device does not act to grant a use license under these patents. Such a license is granted only when the device is used with OneTouch Verio® Test Strip. No test strip supplier other than LifeScan is authorized to grant such a license. The accuracy of results generated with LifeScan meters using test strips manufactured by anyone other than LifeScan has not been evaluated by LifeScan. Pe As your partner in diabetes care, we welcome you to contact us (7 days a week, 8 a.m. - 10 p.m. Eastern Time) at 1 888 567-3003 (English), 1 888 567-3010 (Español), or www.OneTouch.com. PF 3125983 Rev 1 © 2015 LifeScan, Inc. Rev. Date: 10/2014 PF 3125983 Rev 1 Manufactured by: LifeScan Europe Division of Cilag GmbH International Gubelstrasse 34 6300 Zug Switzerland Meter made in China. Yellow = 5mm margin, Red = 10mm margin PF3125983Rev1_OTVF_OB_C_US_en_zug_R4.indd 4 1/12/15 10:48 AM C1 Yellow = 5mm margin, Red = 10mm margin Pe nd in 51 0k ev ie Blood Glucose Monitoring System Owner's Booklet Instructions for Use Yellow = 5mm margin, Red = 10mm margin PF3125983Rev1_OTVF_OB_C_US_en_zug_R4.indd 1 1/12/15 10:49 AM C2 Pe nd in 51 0k ev ie Yellow = 5mm margin, Red = 10mm margin Yellow = 5mm margin, Red = 10mm margin PF3125983Rev1_OTVF_OB_C_US_en_zug_R4.indd 2 1/12/15 10:49 AM C3 Pe nd in 51 0k ev ie Yellow = 5mm margin, Red = 10mm margin Yellow = 5mm margin, Red = 10mm margin PF3125983Rev1_OTVF_OB_C_US_en_zug_R4.indd 3 1/12/15 10:49 AM PF3125983Rev1_OTVF_OB_C_US_en_zug_R4.indd 1 PMS Spot Colors N/A Language Sequence: English CMYK Black Process Colors N/A CPS Reference No.: Refer to References Section in Enable for CPS No. PF No./Rev.: 3125983 Rev 1 in Description: Booklet, Owners, OTVF, US (zug) nd Pe Uncoated Area N/A Uncoated Area 0k 51 ie Special Instructions ev N/A N/A No. of sides: 1 Inside No. of pages: Dieline N/A Dieline Rev. Date: 12-Jan-15 N/A No. of Covers: 4 JDE Item No.: N/A LFS Contact: Susan Cabral Art Agency: ForeignExchange Translations Job No.: 25677 = CUT = SCORE = PERF Leg1 1/12/15 10:49 AM Yellow= 5mm Red=7mm margin ev ie Blood Glucose Monitoring System Pe nd in 51 0k Owner's Booklet PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 1 1/12/15 10:52 AM Yellow= 5mm Red=7mm margin Thanks for choosing OneTouch®! The OneTouch Verio Flex™ Blood Glucose Monitoring System is one of the latest product innovations from OneTouch®. 0k ev ie Your OneTouch Verio Flex™ Meter is designed to connect (sync) with a variety of devices running software applications that let you review and graph your results, and help identify patterns. Meter results are sent to the compatible devices either through BLUETOOTH® SMART (wireless) or USB cable connection. 51 Every OneTouch® Meter is designed to help you test your blood glucose and manage your diabetes. nd in This Owner's Booklet offers a complete explanation of how to use your new meter and testing supplies. It reviews the do's and don'ts of testing your blood glucose level. Please keep your Owner's Booklet in a safe place; you may want to refer to it in the future. Pe We hope OneTouch® products and services will continue to be a part of your life. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 2 1/12/15 10:52 AM Yellow= 5mm Red=7mm margin Compatible Wireless Devices ev ie Visit www.OneTouch.com for information on which wireless devices are compatible with your OneTouch Verio Flex™ Meter, and where/how to download the software application on your compatible wireless device. 0k Meter Power Meter symbols and icons 51 Low Battery Battery Empty Control Solution Pe nd in Syncing BLUETOOTH® SMART Feature On History Mode (Past results) Apply Sample Range Indicator Arrow Setting Mode PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 3 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Other symbols and icons Cautions and Warnings: Refer to the Owner's Booklet and inserts that came with your system for safety-related information. ev ie Direct current Before you begin Pe nd in 51 0k Before using this product to test your blood glucose, carefully read this Owner's Booklet, and the inserts that come with the OneTouch Verio® Test Strips, OneTouch Verio® Control Solution and the OneTouch® Delica® Lancing Device. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 4 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin IMPORTANT SAFETY INSTRUCTIONS: ev ie • This meter and lancing device are for single patient use only. Do Not share them with anyone else, including family members! Do Not use on multiple patients! • After use and exposure to blood, all parts of this kit are considered biohazardous. A used kit may potentially transmit infectious diseases even after you have performed cleaning and disinfection. 51 0k For more information see: FDA Public Health Notification: "Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Bloodborne Pathogens: Initial Communication" (2010) http://www.fda.gov/ MedicalDevices/Safety/AlertsandNotices/ucm224025.htm. Pe nd in CDC Clinical Reminder: "Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Bloodborne Pathogens" (2010) http://www.cdc.gov/ injectionsafety/Fingerstick-DevicesBGM.html. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 5 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Intended use ev ie The OneTouch Verio Flex™ Blood Glucose Monitoring System is intended to be used for the quantitative measurement of glucose (sugar) in fresh capillary whole blood samples drawn from the fingertip. The system is intended to be used by a single patient and should not be shared. 51 0k The OneTouch Verio Flex™ Blood Glucose Monitoring System is intended for self-testing outside the body (in vitro diagnostic use) by people with diabetes at home as an aid to monitor effectiveness of diabetes control. The OneTouch Verio Flex™ Blood Glucose Monitoring System is not to be used for the diagnosis of or screening of diabetes or for neonatal use. Pe nd in The OneTouch Verio Flex™ Blood Glucose Monitoring System is not for use on critically ill patients, patients in shock, dehydrated patients or hyperosmolar patients. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 6 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Test principle ie Glucose in the blood sample mixes with the enzyme FAD-GDH (see page 103) in the test strip and a small electric current is produced. The strength of this current calculates your blood glucose level. It then displays the blood glucose result and stores it in the meter memory. ev Use only OneTouch Verio® Control Solution and Test Strips with the OneTouch Verio Flex™ Meter. 51 0k BLUETOOTH® SMART wireless technology nd in BLUETOOTH® SMART wireless technology is used by some smartphones and many other devices. Your OneTouch Verio Flex™ Meter uses BLUETOOTH® SMART wireless technology to pair and to send your glucose results to compatible wireless devices. Pe The OneTouch Verio Flex™ Meter is designed to work with the OneTouch Reveal® Mobile App. NOTE: Some diabetes management apps, including the OneTouch Reveal® Mobile App, may not be available in your country. Visit www.OneTouch.com to learn if the OneTouch Reveal® Mobile App is available in your country. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 7 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Visit www.OneTouch.com for information on which wireless devices are compatible with your OneTouch Verio Flex™ Meter, and where/how to download the software application on your compatible wireless device. ev ie When using the OneTouch Verio Flex™ System, we suggest you pair your OneTouch Verio Flex™ Meter with a compatible wireless device and track your results. See page 31 for pairing instructions. 51 0k Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. nd in This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Pe For Canada - IC: Statement acc. RSS Gen Issue 3, Sect. 7.1.3 This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 8 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 51 0k ev ie NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Pe nd in • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ TV technician for help. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 9 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin If you experience meter interference problems, try moving your meter away from the source of the interference. You can also move the electronic device or its antenna to another location to solve the problem. ev ie These guidelines help ensure that your meter will not affect the operation of other nearby electronic devices. Additionally, other electronic devices should not affect the use of your meter. Pe nd in 51 0k WARNING: The BLUETOOTH® SMART feature on your meter sends test results to your compatible wireless device. To prevent other people's results from being sent to your compatible wireless device, Do Not let anyone else use your meter to test their blood glucose. This meter is for single patient use only. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 10 10 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin ie WARNING: In locations where cell phone use is not permitted, such as hospitals, some healthcare professional offices and airplanes, you should turn the BLUETOOTH® SMART feature off. See page 29 for more information. ev BLUETOOTH® SMART trademark Pe nd in 51 0k The BLUETOOTH® SMART word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by LifeScan Europe is under license. Other trademarks and trade names are those of their respective owners. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 11 11 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Table of Contents Getting to know your system....................................14 Setting up your system.............................................24 Setting up your meter...................................................... 24 ie Connecting to a compatible wireless device ................ 29 Taking a test............................................................... 36 ev Turning the meter off....................................................... 35 0k Testing your blood glucose............................................. 36 Reviewing past results.............................................70 Pe nd in 51 Testing with control solution..........................................60 PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 12 12 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Editing Your Settings................................................ 76 Editing time and date...................................................... 76 Editing your range limits................................................. 77 Caring for your system.............................................80 Battery........................................................................86 Troubleshooting your system..................................90 Detailed information about your system............ 100 10 Index.......................................................................... 110 Pe nd in 51 0k ev ie PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 13 13 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Getting to know your system Your OneTouch Verio Flex™ Blood Glucose Monitoring System 51 0k ev ie Included with your kit: Lancing device Pe nd in OneTouch Verio Flex™ Meter (CR2032 lithium coin cell battery included) Lancets PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 14 OneTouch Verio® Test Strips* 14 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Getting to know your system 1 NOTE: If any item is missing or defective in your kit, contact Customer Service. As your partner in diabetes care, we welcome you to contact us (7 days a week, 8 a.m. - 10 p.m. Eastern Time) at 1 888 567-3003 (English), 1 888 567-3010 (Español), or www.OneTouch.com. Pe nd in 51 0k ev ie NOTE: If another type of lancing device was included, see the separate instructions for that lancing device. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 15 15 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 1 Getting to know your system Available separately: Items pictured below are required, but may not be included in your kit: 51 OneTouch Verio® Level 4 Control Solution* (vial with red cap) OneTouch Verio® Test Strips* nd in OneTouch Verio® Level 3 Control Solution* (vial with blue cap) 0k ev ie They are sold separately. Refer to your meter carton for a list of included items. Pe *OneTouch Verio® Control Solution and Test Strips are available separately. For availability of test strips and control solution, contact Customer Service or ask your pharmacist or healthcare professional. You can use either OneTouch Verio® Level 3 Control Solution or OneTouch Verio® Level 4 Control Solution with your OneTouch Verio Flex™ Meter. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 16 16 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Getting to know your system 1 Pe nd in 51 0k ev ie WARNING: Keep the meter and testing supplies away from young children. Small items such as the battery door, batteries, test strips, lancets, protective covers on the lancets, and control solution vial cap are choking hazards. Do Not ingest or swallow any items. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 17 17 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 1 Getting to know your system Getting to know your OneTouch Verio Flex™ Blood Glucose Monitoring System Pe nd in 51 0k ev ie Meter PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 18 18 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Pe nd in 51 0k ev ie Getting to know your system 1 PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 19 19 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 1 Getting to know your system Getting to know your OneTouch Verio® Test Strip Pe nd in 51 0k ev ie Test strip PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 20 20 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Getting to know your system 1 The Range Indicator feature Pe nd in 51 0k ev ie The OneTouch Verio Flex™ Meter automatically lets you know if your current result is below, above or within your range limits. It does this by displaying your current result with a Range Indicator Arrow, pointing to a corresponding Range Indicator Color Bar below the meter display. Use the Range Indicator Arrow and Color Bar together to interpret your results. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 21 21 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 1 Getting to know your system 3 Possible Range Indicator Displays ie A Range Indicator Arrow will appear just below your result after each test depending upon how you set your low and high range limits in the meter. ev Example Below Range Result Things you should know before using the Range Indicator feature: Example In Range Result Pe nd in 51 0k • The meter comes with pre-set range limits. The pre-set low range limit is 70 mg/dL and the pre-set high range limit is 180 mg/dL. You can change these limits as needed to meet your needs. See page 77 for details on the pre-set range limits and on editing your range limits. • If you decide to change your range limits, the Range Indicator Arrows stored with previous results in meter memory will not change. However, any new tests will display Range Indicator Arrows which reflect your changes. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 22 Example Above Range Result 22 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Getting to know your system 1 Pe nd in 51 0k ev ie This page left blank intentionally. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 23 23 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Setting up your system Setting up your meter Turn your meter on ev ie To turn your meter on, press and hold until the start-up test screen appears. Once the device is on, release . You can also turn the meter on by inserting a test strip. in CAUTION: 51 0k Every time you turn your meter on, a start-up screen will appear for a few seconds. All segments of the display should appear briefly, indicating your meter is working properly. If the meter does not power on, check the battery. Pe nd If you see any missing segments within the start-up screen, there may be a problem with the meter. Contact Customer Service. 1 888 567-3003. NOTE: If you turned the meter on for the first time by inserting a test strip instead of pressing , you will not be able to perform a glucose test until you complete the first time setup. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 24 24 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Setting up your system 2 First time setup ev ie until the startTo turn your meter on, press and hold up screen appears. Once the device is on, release . The meter will now automatically prompt you to set the time and date. The SET icon will appear on the screen to indicate that the meter has entered setup mode. Setting the time Hour will flash nd in 51 0k • If the hour displayed is correct, press to confirm. • If the hour displayed is not correct, press or to change the hour and press to confirm. Pe Minutes will flash • If the minutes displayed to is correct, press confirm. • If the minutes displayed is not correct, press or to change the minutes and press to confirm. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 25 25 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 2 Setting up your system AM/PM will flash Setting the date 0k ev ie • If the AM/PM displayed to is correct, press confirm. • If the AM/PM displayed is not correct, press or to change AM/PM and press to confirm. in Year will flash 51 After completing the time setup, the meter will automatically move to date setup. Pe nd • If the year displayed to is correct, press confirm. • If the year displayed is not correct, press or to change the year and press to confirm. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 26 26 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Setting up your system 2 ie ev • If the month displayed to is correct, press confirm. • If the month displayed is not correct, press or to change the month and press to confirm. Month will flash 0k Day will flash nd in 51 • If the day displayed is to correct, press confirm. • If the day displayed is not correct, press or to change the day and press to confirm. Pe You are now ready to take a test. See the section Testing your blood glucose in Chapter 3. NOTE: After completing first time setup, a screen with three dashes will appear. Once you begin testing, your last result will appear in place of the three dashes, along with the date and time the test was taken. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 27 27 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 2 Setting up your system Adjusting the time and date settings after first time setup ie You can adjust the meter's time and date settings after to turn the meter on, first time setup. Press and hold then press and hold and at the same time. The SET screen will appear. See page 76. Pe nd in 51 0k ev After adjusting the settings, your meter will exit settings mode and your last result screen will appear. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 28 28 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Setting up your system 2 Connecting to a compatible wireless device Turning the BLUETOOTH® SMART feature on or off 0k ev ie In order to connect your meter with your compatible wireless device, the BLUETOOTH® SMART feature will need to be turned on. The symbol will appear on the meter screen when the BLUETOOTH® SMART feature is on. When the symbol is not present on the screen the BLUETOOTH® SMART feature is off. Pe nd in 51 • To turn the BLUETOOTH® SMART feature on press and at the same time. • To turn the BLUETOOTH® SMART feature off press and at the same time. The symbol indicates the BLUETOOTH® SMART feature is on NOTE: The BLUETOOTH® SMART feature will turn OFF during a blood glucose test. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 29 29 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 2 Setting up your system Pairing Overview ev ie Pairing allows your OneTouch Verio Flex™ Meter to communicate with compatible wireless devices. The devices must be within 26 feet of each other to pair and sync. Download the OneTouch Reveal® Mobile App from the appropriate app store before pairing your meter and compatible wireless device. 0k NOTE: Some diabetes management apps, including the OneTouch Reveal® Mobile App, may not be available in your country. Visit www.OneTouch.com to learn if the OneTouch Reveal® Mobile App is available in your country. nd in 51 Multiple OneTouch Verio Flex™ Meters can be paired with your compatible wireless device. For example, your compatible wireless device can be paired with a meter at home and another at work. To pair multiple meters, repeat the pairing instructions for each meter. See page 31 for pairing instructions. Pe Your OneTouch Verio Flex™ Meter can be paired with multiple compatible wireless devices. To pair multiple compatible wireless devices, repeat the pairing instructions for each compatible wireless device. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 30 30 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Setting up your system 2 Pairing Instructions 1. Start by turning your meter on using the button ie ev 0k The symbol will appear to indicate that the BLUETOOTH® SMART feature is on. 2. The BLUETOOTH® SMART feature is turned on by and together pressing Pe nd in 51 3. Open the OneTouch Reveal® Mobile App and follow instructions to pair meter with your compatible wireless device PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 31 31 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 2 Setting up your system Pe nd in 51 0k ev ie 4. Look for "OneTouch" and the last 4 characters of the meter serial number on the compatible wireless device display to correctly identify your meter PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 32 32 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Setting up your system 2 5. When prompted by the OneTouch Reveal® Mobile App, the meter will display a six digit PIN number Enter the PIN number into your wireless compatible device using the keypad on your compatible wireless device. ie CAUTION: in 51 0k ev Make sure the PIN you enter on your compatible device matches the PIN on your meter display. If a PIN number unexpectedly appears on your meter display, cancel the PIN request by either inserting a test strip to take a test or button to enter History Mode. press the Pe nd Example of PIN number display on meter 6. Wait for your compatible wireless device to indicate that your meter and compatible wireless device are paired PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 33 33 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 2 Setting up your system Syncing to send results wirelessly to the OneTouch Reveal® Mobile App ie After pairing the meter with your compatible wireless device, you are ready to send results to the OneTouch Reveal® Mobile App. ev 1. Open the OneTouch Reveal® Mobile App on your compatible wireless device 0k to turn the meter on and make sure 2. Press and hold the BLUETOOTH® SMART feature is ON as indicated by ( ) 51 and at the same time to turn the If needed, press BLUETOOTH® SMART feature on. nd in The Sync symbol ( ) flashes on the meter display. "Syncing Data" will appear on the app to notify you that the meter is communicating with the app. Pe Syncing Data After syncing, the Sync symbol will disappear, the "Syncing Data" message will disappear on the app, and the app will display a list of any new results sent from the meter. NOTE: Inserting a test strip during the transmission will cancel the transfer of all results. The flashing symbol appears on the screen and you can proceed with testing. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 34 34 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Setting up your system 2 Turning the meter off There are three ways to turn your meter off: ev ie for several seconds until the meter • Press and hold turns off. • Remove the test strip. • Your meter will turn off by itself if left alone for two minutes. Pe nd in 51 0k NOTE: Following a glucose test, the meter will still be available for BLUETOOTH® SMART connection for up to 4 hours. See page 71 for more details. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 35 35 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test Testing your blood glucose Preparing for a blood glucose test 51 0k OneTouch Verio Flex™ Meter OneTouch Verio® Test Strips Lancing device Sterile lancets ev Have these things ready when you test: ie NOTE: Many people find it helpful to practice testing with control solution before testing with blood for the first time. See page 60. NOTE: Pe nd in • Use only OneTouch Verio® Test Strips. • Unlike some blood glucose meters, no separate step to code your OneTouch Verio Flex™ System is required. • Testing must be done within operating temperature range (50-104°F). • Make sure your meter and test strips are about the same temperature before you test. • Keep test strips in a cool, dry place between 41°F and 86°F. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 36 36 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 Pe nd in 51 0k ev ie • Do Not test if there is condensation (water build-up) on your meter. Move your meter and test strips to a cool, dry spot and wait for the meter surface to dry before testing. • Do Not open the test strip vial until you are ready to remove a test strip and perform a test. Use the test strip immediately after removing it from the vial. • Tightly close the cap on the vial immediately after use to avoid contamination and damage. • Store unused test strips only in their original vial. • Do Not return the used test strip to the vial after performing a test. • Do Not re-use a test strip that had blood, control solution, or any contaminants applied to it. Test strips are for single use only. • With clean, dry hands, you may touch the test strip anywhere on its surface. Do Not bend, cut or modify the test strip in any way. • When you first open a vial of test strips, record the discard date on the label. Refer to the test strip insert or vial label for instructions on determining the discard date. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 37 37 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test ie • Comparing your blood glucose test results taken with this meter to your results taken from a different meter is not recommended. Results may differ between meters and are not a useful measure of whether your meter is working properly. ev IMPORTANT: If another person assists you with testing, the meter should always be cleaned prior to use by that person. See page 80. 0k CAUTION: Pe nd in 51 • The OneTouch Verio Flex™ Blood Glucose Monitoring System should not be used for patients within 24 hours of receiving a D-xylose absorption test as it may cause inaccurately high results. • Do Not use the OneTouch Verio® Family of Meters when PAM (Pralidoxime) is known or suspected to be in the patient's whole blood sample. • Do Not use your test strips if your vial is damaged or left open to air. This could lead to error messages or inaccurate results. Contact Customer Service immediately if the test strip vial is damaged. 1 888 567-3003. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 38 38 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 Pe nd in 51 0k ev ie • If you cannot test due to a problem with your testing supplies, contact your healthcare professional. Failure to test could delay treatment decisions and lead to a serious medical condition. • The test strip vial contains drying agents that are harmful if inhaled or swallowed and may cause skin or eye irritation. • Do Not use test strips after the expiration date (printed on the vial) or the discard date, whichever comes first, or your results may be inaccurate. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 39 39 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test Pe nd in 51 0k ev ie Getting to know your OneTouch® Delica® Lancing Device PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 40 40 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 NOTE: Pe nd in 51 0k ev ie • The OneTouch® Delica® Lancing Device uses ONLY OneTouch® Delica® Lancets. • If another type of lancing device was included, see the separate instructions for that lancing device. • The OneTouch Verio Flex™ Blood Glucose Monitoring System has not been evaluated for Alternate Site Testing (AST). Use only fingertips when testing with the system. • The OneTouch® Delica® Lancing System does not include the materials needed to perform Alternate Site Testing (AST). The OneTouch® Delica® Lancing System should not be used on the forearm or palm with the OneTouch Verio Flex™ Blood Glucose Monitoring System. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 41 41 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test Lancing precautions CAUTION: To reduce the chance of infection and disease spread by blood: Pe nd in 51 0k ev ie • Make sure to wash the sample site with soap and warm water, rinse and dry before sampling. • The lancing device is intended for a single user. Never share a lancet or lancing device with anyone. • Always use a new, sterile lancet each time you test. • Always keep your meter and lancing device clean (See page 80). • The meter and lancing device are for single patient use only. Do Not share them with anyone, including family members! Do Not use on multiple patients! • After use and exposure to blood, all parts of this kit are considered biohazardous. A used kit may transmit infectious diseases even after you have performed cleaning and disinfection. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 42 42 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 Preparing the lancing device 1. Remove the lancing device cap Pe nd in 51 0k ev ie Remove the cap by turning it counterclockwise and then pulling it straight off of the device. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 43 43 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test 2. Insert a sterile lancet into the lancing device ev ie Align the lancet as shown here, so that the lancet fits into the lancet holder. Push the lancet into the device until it snaps into place and is fully seated in the holder. Pe nd in 51 0k Twist the protective cover one full turn until it separates from the lancet. Save the protective cover for lancet removal and disposal. See page 57. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 44 44 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 3. Replace the lancing device cap 51 0k ev ie Place the cap back onto the device; turn clockwise to secure the cap. Pe nd in Do Not overtighten. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 45 45 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test 4. Adjust the depth setting 51 0k ev ie The lancing device has seven puncture depth settings, numbered 1 through 7. Smaller numbers are for a shallower puncture and the larger numbers are for a deeper puncture. Shallower punctures work for children and most adults. Deeper punctures work well for people with thick or callused skin. Turn the depth wheel to choose the setting. nd in NOTE: A shallower fingertip puncture may be less painful. Try a shallower setting first and increase the depth until you find the one deep enough to get a blood sample of the proper size. 5. Cock the lancing device Pe Slide the cocking control back until it clicks. If it does not click, it may already have been cocked when you inserted the lancet. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 46 46 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 Preparing the meter 1. Insert a test strip to turn the meter on in 51 0k ev ie Insert a test strip into the test strip port with the gold side of the test strip and the two silver prongs facing you. Pe nd NOTE: No separate step to code the meter is required. The flashing blood drop icon ( ) appears on the display. You can now apply your blood sample to the test strip. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 47 47 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test Getting a blood sample from the fingertip Choose a different puncture site each time you test. Repeated punctures in the same spot may cause soreness and calluses. 1. Puncture your finger Pe nd in 51 0k Hold the lancing device firmly against the side of your finger. Press the release button. Remove the lancing device from your finger. ev ie Before testing, wash your hands thoroughly with warm, soapy water. Rinse and dry completely. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 48 48 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 2. Get a round drop of blood ss Gently squeeze and/or massage your fingertip until a round drop of blood forms on your fingertip. ev 0k nd in 51 NOTE: If the blood smears or runs, Do Not use that sample. Dry the area and gently squeeze another drop of blood or puncture a new site. Pe m, ie Taking a test 3 PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 49 49 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test Applying blood and reading results Applying the sample 1. Apply the sample to the test strip ie You can apply blood to either side of the test strip. ev Apply your sample to the opening of the channel. nd in 51 0k Be sure to apply your sample immediately after you get a drop of blood. Pe Holding the meter at a slight angle, guide the channel to the blood drop. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 50 50 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 ev ie When it touches your sample, the test strip wicks blood into the channel. 0k 2. Wait for the channel to fill completely 51 The blood drop will be drawn into the narrow channel. The channel should fill completely. The channel turns red and the meter will count down from 5 to 1. Pe nd in Blood should not be applied on the top of the test strip or to the top edge of the test strip. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 51 51 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test NOTE: Pe nd in 51 0k ev ie • Do Not smear or scrape the sample with the test strip. • Do Not press the test strip too firmly against the puncture site or the channel may be blocked from filling properly. • Do Not apply more blood to the test strip after you have moved the drop of blood away. • Do Not move the test strip in the meter during a test or you may get an error message or the meter may turn off. • Do Not remove the test strip until the result is displayed or the meter will turn off. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 52 52 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 ie Example Below Range Result Example In Range Result CAUTION: 51 0k ev Your result appears on the display, along with the unit of measure, and the date and time of the test. After your glucose result appears, the meter will also display a Range Indicator Arrow below your glucose result to indicate if your result is below, above or within your range limits (see page 21). The arrow will point to the appropriate Range Indicator Color Bar on the meter as a visual reminder. Viewing your result Pe nd in Do Not make immediate treatment decisions based on the Range Indicator feature. Treatment decisions should be based on the numerical result and healthcare professional recommendation and not solely on where your result falls within your range limits. Example Above Range Result WARNING: Confirm that the unit of measure mg/dL is displayed. If your display shows mmol/L rather than mg/dL, stop using the meter and contact Customer Service. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 53 53 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test Interpreting unexpected results Refer to the following cautions when your results are higher or lower than what you expect. ie CAUTION: ev Low results in 51 0k If your result is below 70 mg/dL or is shown as LO (meaning the result is less than 20 mg/dL), it may mean hypoglycemia (low blood glucose). This may require immediate treatment according to your healthcare professional's recommendations. Although this result could be due to a test error, it is safer to treat first, then do another test. Pe nd NOTE: When your glucose result is below 20 mg/dL, both the LO and the Range Indicator Arrow will flash on the meter screen. CAUTION: Dehydration and low results You may get false low results if you are severely dehydrated. If you think you are severely dehydrated, contact your healthcare professional immediately. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 54 54 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 CAUTION: High results ev ie • If your result is above 180 mg/dL, it may mean hyperglycemia (high blood glucose) and you should consider re-testing. Talk to your healthcare professional if you are concerned about hyperglycemia. in 51 0k • HI is displayed when your result is over 600 mg/dL. You may have severe hyperglycemia (very high blood glucose). Re-test your blood glucose level. If the result is HI again, this indicates a severe problem with your blood glucose control. Obtain and follow instructions from your healthcare professional immediately. Pe nd NOTE: When your glucose result is above 600 mg/dL, both the HI and the Range Indicator Arrow will flash on the meter screen. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 55 55 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test CAUTION: Repeated unexpected results 51 0k ev ie • If you continue to get unexpected results, check your system with control solution. • If you are experiencing symptoms that are not consistent with your results and you have followed all instructions in this Owner's Booklet, call your healthcare professional. Never ignore symptoms or make significant changes to your diabetes management program without speaking to your healthcare professional. Unusual red blood cell count Pe nd in A hematocrit (percentage of your blood that is red blood cells) that is either very high (above 60%) or very low (below 20%) can cause false results. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 56 56 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 Removing the used lancet NOTE: This lancing device has an ejection feature, so you do not have to pull out the used lancet. ie ev 51 0k Remove the cap by turning it counterclockwise and then pulling it straight off of the device. 1. Remove the lancing device cap 2. Cover the exposed lancet tip Pe nd in Before removing the lancet, place the lancet protective cover on a hard surface then push the lancet tip into the cupped side of the cover. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 57 57 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test 3. Eject the lancet ie Slide the ejection control forward until the lancet comes out of the lancing device. Return the ejection control to its back position. Pe nd in 51 0k ev If the lancet fails to eject properly, cock the device again and then slide the ejection control forward until the lancet comes out. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 58 58 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 4. Replace the lancing device cap 51 0k ev ie Place the cap back onto the device; turn clockwise to secure the cap. Pe nd in Do Not overtighten. It is important to use a new lancet each time you obtain a blood sample. Do Not leave a lancet in the lancing device. This will help prevent infection and sore fingertips. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 59 59 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test Disposing of the used lancet and test strip ie Discard the used lancet carefully after each use to avoid unintended lancet stick injuries. Used lancets and test strips may be considered biohazardous waste in your area. Be sure to follow your healthcare professional's recommendations or local regulations for proper disposal. ev Wash hands thoroughly with soap and water after handling the meter, test strips, lancing device and cap. 0k Testing with control solution 51 Control solution testing precautions nd in OneTouch Verio® Control Solution is used to check that the meter and test strips are working together properly and that the test is performing correctly. (Control solution is available separately.) NOTE: Pe • Use only OneTouch Verio® Level 3 Control Solution or OneTouch Verio® Level 4 Control Solution with your OneTouch Verio Flex™ Meter. Either level can be used to check your system. • When you first open a new vial of control solution, record the discard date on the vial label. Refer to the control solution insert or vial label for instructions on determining the discard date. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 60 60 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 • Tightly close the cap on the control solution vial immediately after use to avoid contamination or damage. See page 36 for more information on testing. ie CAUTION: Pe nd in 51 0k ev • Do Not swallow or ingest control solution. • Do Not apply control solution to the skin, eyes, ears or nose as it may cause irritation. • Do Not use control solution after the expiration date (printed on the vial label) or the discard date, whichever comes first, or your results may be inaccurate. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 61 61 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test When to do a control solution test ev ie • When you open a new vial of test strips. • If you suspect that the meter or test strips are not working properly. • If you have had repeated unexpected blood glucose readings. • If you drop or damage the meter. 51 0k Preparing your meter for a control solution test Pe nd in 1. Insert a test strip to turn the meter on PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 62 62 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 ev or until the 3. Press control solution icon ( ) appears on the display ie 2. Wait for the flashing blood drop icon ( ) to appear on the display 51 0k on Preparing the control solution in 1. Before removing the cap, shake the vial gently Pe nd 2. Remove the vial cap and place it on a flat surface with the top of the cap pointing up 3. Squeeze the vial to discard the first drop PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 63 63 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test in 51 0k ev ie 4. Wipe both the tip of the control solution vial and the top of the cap with a clean, damp tissue or cloth Pe nd 5. Squeeze a drop into the small well on the top of the cap or onto another clean, non-absorbent surface PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 64 64 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 Applying the control solution ev ie 1. Hold the meter so that the side edge of the test strip is at a slight angle to the drop of control solution 51 0k 2. Touch the channel on the side of the test strip to the control solution Pe nd in 3. Wait for the channel to fill completely PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 65 65 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test ev ie After the control solution is applied, the meter will count down until the test is complete. Your result is displayed along with the date, time, unit of measure, and (for control solution) and stored in the meter. Viewing your control solution result 0k Control solution results can be seen when reviewing past results on the meter. Pe nd in 51 CAUTION: Make sure you press or until the control appears before you begin a control solution solution icon test. Invalid results may be logged into your history if you applied control solution to the test strip without following the steps beginning on page 62. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 66 66 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 Checking if the result is in range ev ie Each vial of test strips has both OneTouch Verio® Level 3 Control Solution and OneTouch Verio® Level 4 Control Solution ranges printed on its label. Compare the result displayed on the meter to either the OneTouch Verio® Level 3 Control Solution or OneTouch Verio® Level 4 Control Solution range printed on the test strip vial, depending on the type of control solution you used. OneTouch Verio® Level 4 Control Solution Control Range 298-403 mg/dL nd in 51 0k Example range OneTouch Verio® Level 3 Control Solution Control Range 102-138 mg/dL Pe CAUTION: The range printed on the control solution vial is for control solution tests only and is not a recommended range for your blood glucose level. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 67 67 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 3 Taking a test Causes of out-of-range results Out-of-range results may be due to: in 51 0k ev ie • Not following the instructions for performing a control solution test. • Control solution is contaminated, expired, or past its discard date. • Test strip or test strip vial is damaged, expired, or past its discard date. • Meter, test strips and/or control solution were not all at the same temperature when the control solution test was performed. • A problem with the meter. • Dirt or contamination in the small well on the top of the control solution cap. nd CAUTION: Pe If you continue to get control solution results that fall outside the range printed on the test strip vial, Do Not use the meter, test strips, or control solution. Contact Customer Service. 1 888 567-3003. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 68 68 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Taking a test 3 Cleaning the control solution cap Pe nd in 51 0k ev ie Clean the top of the control solution cap with a clean, damp tissue or cloth. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 69 69 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Reviewing past results Reviewing past results on your meter to turn ev 1. When the meter is off, press and hold History Mode on ie Your meter stores your most recent 500 blood glucose and control solution test results and displays them in the order the tests were taken. The ( ) symbol will appear on your screen when in History Mode. 0k The ( ) symbol indicates you are viewing your past results. 51 ) symbol indicates if the result was below, The ( above or within range at the time of the test, by pointing to the appropriate color bar. Pe nd in 2. Scroll through your results by pressing to move backwards and to move forward through your results PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 70 70 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Reviewing past results 4 Using the meter without syncing to an app ev ie The meter can be used without a compatible wireless device or the app. You can still test your blood glucose and review up to 500 results on the meter. Sending your results to the app 51 0k If the BLUETOOTH® SMART feature on the meter is turned on, indicated by the BLUETOOTH® SMART symbol ( ), the meter will automatically send the latest result to any paired wireless compatible device. The compatible wireless device must have the app running and have already been paired to the meter before sending a result. nd in NOTE: The compatible wireless device must have the app open and have already been paired to the meter before sending a result. See page 30. Pe NOTE: If the BLUETOOTH® SMART feature on the meter is turned off, or the meter is out of range, the result is not sent to the compatible wireless device. The result is saved in the meter memory with the current date and time, and will be sent to the app the next time you sync. The sent results are also stored in the meter. To sync, the app must be open and running on your compatible wireless device. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 71 71 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 4 Reviewing past results To ensure that glucose test results are successfully sent to the app, turn on the BLUETOOTH® SMART feature and check the following: Pe nd in 51 0k ev ie • The compatible wireless device and meter are both turned on, and the app is running. • The meter is correctly paired with your compatible wireless device. • The Bluetooth feature on both devices is running (indicated by ) and the devices are within 26 feet of each other. • The meter will attempt to transmit results up to 4 hours after a test, even if the meter appears to be off. This is indicated by the BLUETOOTH® SMART symbol ( ) remaining on the meter screen. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 72 Example 72 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Reviewing past results 4 If you are still unable to send results to the compatible wireless device, please call Customer Service. 1 888 567-3003. Pe nd in 51 0k ev ie NOTE: Inserting a test strip during the transmission will cancel the transfer of all results. The symbol appears on the screen and you can proceed with testing. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 73 73 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 4 Reviewing past results Downloading results to a computer ev ie Your meter can work with diabetes management software, which provides a visual way to track key factors that affect your blood sugar. To learn more about diabetes management tools available to you, contact Customer Service. As your partner in diabetes care, we welcome you to contact us (7 days a week, 8 a.m. - 10 p.m. Eastern Time) at 1 888 567-3003 (English), 1 888 567-3010 (Español), or www.OneTouch.com. 0k Connect only to a computer certified to UL 60950-1 ( ). Pe nd in 51 To transfer meter data, follow the instructions provided with the diabetes management software product to download the results from the meter. You will need a standard micro USB interface cable to connect your OneTouch Verio Flex™ Meter to a computer to download results (not included). PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 74 74 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Reviewing past results 4 ie ev 51 0k If you are unable to download your results to a computer, please call Customer Service. 1 888 567-3003. in ). Do Not insert a test strip while the meter is connected to a computer. nd rn Pe are, Once the command to start the download is sent from the computer to the meter, the meter display will show the flashing Sync symbol ( ) indicating that the meter is in communication mode. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 75 75 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Editing Your Settings Editing time and date ie You can adjust the meter's time and date settings after first time setup. Press and hold to turn the meter on, then press and hold and at the same time. The SET screen will appear, and the hour will flash. ev For instructions on adjusting the time and date, see page 25. 51 0k After adjusting the settings, you will exit settings mode and your last glucose result screen will appear. The adjusted time and date will be displayed once a new glucose test has been completed and the result appears on the screen. in NOTE: You will not be able to perform a blood glucose test until you finish editing the time and date. Pe nd NOTE: The OneTouch Reveal® Mobile App on your compatible wireless device checks and updates the time and date in your meter each time you sync. Check the time and date often on your compatible wireless device to be sure they are correct. See the App instructions for more information. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 76 76 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Editing Your Settings 5 Editing your range limits 0k ev ie Your meter uses low and high range limits to tell you when your result is below, above or within your set range. The meter comes with pre-set range limits that can be changed. The pre-set low range limit is 70 mg/dL and the pre-set high range limit is 180 mg/dL. To edit the pre-set range limits press and hold and at the same time. The SET screen will appear with the current low range limit displayed, and the number and range indicator arrow will flash. 51 NOTE: The low and high range limits you set apply to all glucose test results. This includes tests taken before or after mealtimes, medications and around any other activities that may affect your blood glucose. in CAUTION: Pe nd Be sure to talk to your healthcare professional about the low and high range limits that are right for you. When selecting or changing your limits, you should consider factors such as your lifestyle and diabetes therapy. Never make significant changes to your diabetes care plan without consulting your healthcare professional. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 77 77 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 5 Editing Your Settings ie ev 0k • To accept the pre-set low range limit, press . • To edit the pre-set low range limit, press or to change the value between 60 mg/dL-110 mg/dL, and then press . 1. Review the pre-set low range limit displayed 2. Review the pre-set high range limit displayed Pe nd in 51 • To accept the pre-set high range limit, press . • To edit the pre-set high range limit, press or to change the value between 90 mg/dL-300 mg/dL, and then press . Your meter will exit settings mode and your last result screen will appear. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 78 78 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Editing Your Settings 5 NOTE: If you change your range limits, this will only affect whether future test results are displayed as below, above or within your range limits. Changing your range limits does not affect how past results are displayed. ie NOTE: You will not be able to perform a glucose test until you finish editing the range limits. Pe nd in 51 0k ev NOTE: You can use the OneTouch Reveal® Mobile App on your compatible wireless device to change the range limits stored in your meter. See the instructions that came with the app for more information. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 79 79 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Caring for your system Storing your system ev Cleaning and disinfection ie Store your meter, test strips, control solution and other items in your carrying case. Keep in a cool, dry place between 41°F and 86°F. Keep all items away from direct sunlight and heat. Pe nd in 51 0k Cleaning and disinfection are different. Both should be performed at least once per week. Cleaning is part of your normal care and maintenance, but does not kill germs. You should clean your meter, lancing device and cap before disinfecting. After use and exposure to blood, all parts of this kit may transmit infectious diseases. Disinfection is the only way to reduce your exposure to disease. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 80 80 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Caring for your system 6 For cleaning information, see page 82 and for disinfecting information, see page 83. 0k ev ie For cleaning and disinfecting, Clorox® Germicidal Wipes* containing 0.55% sodium hypochlorite as the active ingredient have been shown to be safe for use with the OneTouch Verio Flex™ System and can be obtained from retail websites offering disinfection products, e.g., www.officedepot.com. For more information on purchase options, visit www.onetouch.com/disinfection, or contact Customer Service. 1 888 567-3003. in 51 *Other products, such as Clorox® Disinfecting Wipes, have not been tested and should not be used. Only Clorox® Germicidal Wipes should be used. Follow manufacturer's instruction for handling and storage of wipes. Clorox® is a registered trademark of the Clorox Company. Pe nd IMPORTANT: If another person assists you with testing, the meter, lancing device and cap should always be cleaned and then disinfected prior to use by that person. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 81 81 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 6 Caring for your system Cleaning your meter, lancing device and cap 1. Use a Clorox® Germicidal Wipe to wipe the outside of the meter and lancing device ev ie The meter, lancing device and cap should be cleaned at least once per week. Be sure to clean the meter, lancing device and cap before disinfecting. 51 0k To clean your meter, hold it with the test strip port pointed down. Be sure to squeeze out any excess liquid before you wipe the meter. nd in Wipe the outside of the lancing device cap. Pe 2. Wipe dry with a clean, sterile gauze PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 82 82 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Caring for your system 6 Disinfecting your meter, lancing device and cap ie The meter, lancing device and cap should be disinfected at least once per week. Be sure to clean the meter, lancing device and cap before disinfecting. ev 1. First, clean your meter, lancing device and cap prior to disinfecting 0k Follow step 1 of page 82. in 51 2. Use a new Clorox® Germicidal Wipe to wipe the outside of the meter, lancing device and cap until the surface is damp Pe nd Be sure to squeeze out any excess liquid before you wipe the meter. Hold the meter with the test strip port pointed down. Allow the surface of the meter, lancing device and cap to remain damp for 1 minute. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 83 83 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 6 Caring for your system 3. Wipe dry with a clean, sterile gauze Wash hands thoroughly with soap and water after handling the meter, lancing device and cap. in 51 0k ev ie • Do Not use alcohol or any other solvent. • Do Not allow liquids, dirt, dust, blood or control solution to enter the test strip port or the data port. • Do Not squeeze the germicidal wipe into test strip port. • Do Not spray cleaning solution on the meter and lancing device. • Do Not immerse the meter and lancing device in any liquid. Pe nd The OneTouch Verio Flex™ System withstood cleaning and disinfection cycles well in excess of LifeScan's recommendation. See page 85 for more details. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 84 84 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Caring for your system 6 ev ie Examples of damage to the meter may include fogged display, cracked housing or lens, illegible labels, button not working or meter malfunction (such as repeated error messages). Examples of damage to the lancing device and cap may include cracking, illegible depth setting numbers and lancing device malfunction (such as failure to load, cock or release). in 51 0k Do Not use your meter or lancing device if you see evidence of such damage. If you have questions about cleaning or disinfecting, or if you see evidence of physical damage, contact Customer Service. As your partner in diabetes care, we welcome you to contact us (7 days a week, 8 a.m. - 10 p.m. Eastern Time) at 1 888 567-3003 (English), 1 888 567-3010 (Español), or www.OneTouch.com. nd Cleaning and Disinfecting Cycles Pe The meter, lancing device and cap can be cleaned daily for 3 years and have been tested up to 2879 cleaning cycles. The meter, lancing device and cap can be disinfected weekly for 3 years, and have been tested up to 412 cleaning and disinfection cycles. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 85 85 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Battery Replacing the battery Your OneTouch Verio Flex™ Meter uses one CR2032 lithium coin cell battery. ev ie IMPORTANT: Use only one CR2032 lithium coin cell battery with your meter. Do Not use rechargeable batteries. Use of an incorrect battery type may result in your meter providing fewer tests than normal. 0k If the meter does not turn on, you may need to replace the battery. See below for instructions. 51 WARNING: Certain batteries may cause leaking which can damage the meter or cause the battery to lose power sooner than normal. Replace leaking battery immediately. nd in NOTE: After replacing the battery, you will be prompted to set time and date, as if you are turning the meter on for the first time. 1. Remove the old battery Pe Start with the meter turned off. Remove the battery cover by sliding it downward. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 86 86 1/12/15 10:53 AM Pull up on the battery ribbon to lift the battery out of the compartment. the 0k 2. Insert the new battery nd in 51 Insert one CR2032 lithium coin cell battery on top of the battery ribbon, with the plus (+) side up. Pe can oner Do Not remove the battery while the meter is connected to a computer. ie tery Battery 7 ev um Yellow= 5mm Red=7mm margin If the meter does not power on after you have replaced the meter battery, check that the battery is correctly installed. If the meter still does not power on, contact Customer Service. 1 888 567-3003. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 87 87 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 7 Battery 0k ev ie 3. Replace battery cover by sliding it upwards onto the meter 51 4. Check your meter settings in Removing the meter battery will not affect your stored results. However, you will need to check your date and time settings. nd 5. Dispose of battery Pe Dispose of the battery according to your local environmental regulations. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 88 88 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Battery 7 Pe nd in 51 0k ev ie This page left blank intentionally. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 89 89 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Troubleshooting your system Error and other messages ie The OneTouch Verio Flex™ Meter displays messages when there are problems with the test strip, with the meter or when your glucose levels are above 600 mg/dL or below 20 mg/dL. Improper use may cause an inaccurate result without producing an error message. What it means in 51 You may have a very low blood glucose level (severe hypoglycemia), below 20 mg/dL. 0k ev NOTE: If the meter is on but does not operate (locks-up), contact Customer Service. 1 888 567-3003. Pe nd NOTE: When your glucose result is below 20 mg/dL, both the LO and the Range Indicator Arrow will flash on the meter screen. What to do This may require immediate treatment. Although this message could be due to a test error, it is safer to treat first and then do another test. Always treat according to your healthcare professional's recommendations. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 90 90 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Troubleshooting your system 8 What it means ie You may have a very high blood glucose level (severe hyperglycemia), over 600 mg/dL. ev NOTE: When your glucose result is above 600 mg/dL, both the HI and the Range Indicator Arrow will flash on the meter screen. 0k What to do Pe nd in 51 Re-test your blood glucose level. If the result is HI again, obtain and follow instructions from your healthcare professional right away. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 91 91 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 8 Troubleshooting your system What it means Meter is too hot (above 104°F) to perform a test. ie What to do ev Move the meter and test strips to a cooler area. Insert a new test strip when the meter and test strips are within the operating range (50-104°F). If you do not get another HI .t message, you can proceed with testing. Pe nd in 51 0k If this message continues to appear, contact Customer Service. 1 888 567-3003. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 92 92 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Troubleshooting your system 8 What it means Meter is too cold (below 50°F) to perform a test. ie What to do ev Move the meter and test strips to a warmer area. Insert a new test strip when the meter and test strips are within the operating range (50-104°F). If you do not get another LO.t message, you can proceed with testing. Pe nd in 51 0k If this message continues to appear, contact Customer Service. 1 888 567-3003. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 93 93 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 8 Troubleshooting your system Error Screens 51 0k ev ie If there is a problem with your meter, there are six possible error screens that may appear. Along with an error number, there is also an error code in the upper left corner of your meter screen. If you cannot resolve the error with your meter, contact Customer Service. 1 888 567-3003. They will refer to the error number and code to help troubleshoot the problem. Pe nd in Example Error Screen Code PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 94 94 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Troubleshooting your system 8 What it means There is a problem with the meter. ie What to do 51 What it means 0k ev Do Not use the meter. Contact Customer Service. 1 888 567-3003. nd in Error message could be caused either by a used test strip or a problem with the meter or test strip. Pe What to do Repeat the test with a new test strip; see page 50 or page 65. If this message continues to appear, contact Customer Service. 1 888 567-3003. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 95 95 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 8 Troubleshooting your system What it means The sample was applied before the meter was ready. ie What to do Pe nd in 51 0k ev Repeat the test with a new test strip. Apply a blood or control solution sample only after the flashing symbol appears on the display. If this message continues to appear, contact Customer Service. 1 888 567-3003. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 96 96 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Troubleshooting your system 8 What it means ie ev • Not enough blood or control solution was applied or more was added after the meter began to count down. One of the following may apply: 51 0k • The test strip may have been damaged or moved during testing. • The sample was improperly applied. • There may be a problem with the meter. in What to do Pe nd Repeat the test with a new test strip; see page 50 or page 65. If the error message appears again, contact Customer Service. 1 888 567-3003. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 97 97 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 8 Troubleshooting your system What it means ie The meter has detected a problem with the test strip. Possible cause is test strip damage. ev What to do 51 0k Repeat the test with a new test strip; see page 50 or page 65. If the error message appears again, contact Customer Service. 1 888 567-3003. in What it means Pe nd Meter battery power is low but there is still enough battery power to perform a test. The flashing low ) icon will battery ( continue to appear until the battery is replaced. What to do Replace the meter battery soon. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 98 98 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Troubleshooting your system 8 What it means There is not enough battery power to perform a test. What it means ev 0k Replace the battery immediately. ie What to do nd in 51 No result in memory, such as the first time use or when you have chosen to delete all the results after downloading to a computer. What to do Pe Contact Customer Service to report this occurrence, unless this is your first use of the meter. You can still perform a blood glucose test or control solution test and get an accurate result. 1 888 567-3003. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 99 99 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Detailed information about your system Comparing meter results to laboratory results 0k ev ie Results obtained from the OneTouch Verio Flex™ Meter and laboratory tests are reported in plasma-equivalent units. However, your meter result may differ from your lab result due to normal variation. A result from your OneTouch Verio Flex™ Meter is considered accurate when it is within 15 mg/dL of a laboratory method when the glucose concentration is lower than 75 mg/dL and within 15% of laboratory method when the glucose concentration is 75 mg/dL or higher. in 51 Meter results can be affected by factors that do not affect lab results in the same way. Specific factors that may cause your meter result to vary from your lab result may include: Pe nd • You have eaten recently. This can cause a result from fingertip testing to be up to 70 mg/dL higher than a lab test using blood drawn from a vein.1 • Your hematocrit is above 60% or below 20%. • You are severely dehydrated. For additional information, refer to the OneTouch Verio® Test Strip Insert. Sacks, D.B.: "Carbohydrates." Burtis, C.A., and Ashwood E.R. (ed.), Tietz Textbook of Clinical Chemistry, Philadelphia: W.B. Saunders Company (1994), 959. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 100 100 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Detailed information about your system 9 Guidelines for obtaining an accurate meter to lab comparison Before going to the lab: Pe nd in 51 0k ev ie • Perform a control solution test to make sure your meter is working properly. • Do Not eat for at least 8 hours before you test your blood. • Take your meter and testing supplies with you to the lab. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 101 101 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 9 Detailed information about your system Testing with your OneTouch Verio Flex™ Meter at the lab: ev ie • Test within 15 minutes of the lab test. • Use only a fresh, capillary blood sample from your fingertip. • Follow all instructions in this Owner's Booklet for performing a blood glucose test. 51 0k Comparing your meter results to those taken from another meter Pe nd in Comparing your blood glucose test results taken with this meter to your results taken from a different meter is not recommended. Results may differ between meters and are not a useful measure of whether your meter is working properly. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 102 102 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Detailed information about your system 9 Technical specifications FAD-GDH (flavin adenine dinucleotide dependent glucose dehydrogenase) Automatic shutoff Two minutes after last action Battery ratings 3.0 V d.c. (CR2032 lithium coin cell battery), Battery type One replaceable 3.0 Volt CR2032 lithium coin cell battery (or equivalent) BLUETOOTH® SMART Technology Frequency range: 2.4-2.4835 GHz Operating Range Distance: minimum 26.25 feet (unobstructed) Operating Channels: 40 Channels Security Encryption: 128-bit AES (Advanced Encryption Standard) in Calibration 51 0k ev ie Assay method Plasma-equivalent Compatible with USB 2.0 Memory 500 test results Pe nd Data port type PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 103 103 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 9 Detailed information about your system Temperature: 50-104°F Relative humidity: non-condensing 10-90% Altitude: up to 10,000 feet Hematocrit: 20-60% Reported result range 20-600 mg/dL Sample Fresh capillary whole blood Sample volume 0.4 µL Size 2.05(W) x 3.38(L) x 0.63(T) inches Test time 5 seconds Unit of measure mg/dL 51 0k ev ie Operating ranges Weight in Approximately 1.76 ounces nd Lay User Accuracy Pe User Accuracy of the system was assessed at 3 clinical sites. 172 patients tested their blood using the OneTouch Verio Flex™ System where results were compared to the YSI 2300 Glucose Analyzer laboratory Instrument. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 104 104 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Detailed information about your system 9 Fingertip Results for Glucose Concentrations <75 mg/dL Within ±10 mg/dL Within ±15 mg/dL ev Within ±5 mg/dL ie Percent (and number) of meter results that match the laboratory test 95.2% (20/21) 95.2% (20/21) 76.2% (16/21) 51 0k Fingertip Results for Glucose Concentrations ≥75 mg/dL Percent (and number) of meter results that match the laboratory test Within ±10% Within ±15% 58.3% (88/151) 88.7% (134/151) 98.0% (148/151) nd in Within ±5% Pe Number and percentage of all results falling within ±15 mg/dL or ±15% Within 15 mg/dL or ±15% 97.7% (168/172) PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 105 105 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 9 Detailed information about your system Regression Statistics Samples were tested on each of three test strip lots. Results indicate that the OneTouch Verio Flex™ System compares well with a laboratory method. # of Tests Slope Intercept (mg/dL) 172 172 0.99 95% CI Slope 95% CI Intercept (mg/dL) Std. Error (Sy.x) (mg/dL) R2 0.97 to 1.01 -1.59 to 7.55 14.0 0.98 ev ie # of Subjects Pe nd in 51 0k 2.98 PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 106 106 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Detailed information about your system 9 Precision Within Run Precision (300 Venous Blood Samples Tested per Glucose Level) Mean Glucose (mg/dL) 40 36.5 0.83 2.26 90 88.5 1.72 1.95 0k 127.9 2.50 1.95 199.3 3.94 1.98 344.6 6.18 1.79 51 130 200 Coefficient of Variation (%) ev Target Glucose (mg/dL) 350 Standard Deviation (mg/dL) ie Data generated using the OneTouch Verio Flex™ Meter. Pe nd in Results show that the greatest variability observed between test strips when tested with blood is 0.83 mg/dL SD or less at glucose levels less than 75 mg/dL or 1.98% CV or less at glucose levels at 75 mg/dL or above. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 107 107 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 9 Detailed information about your system Total Precision (600 Control Solution Tests per Glucose Level) Standard Deviation (mg/dL) Level 1 (25-49) 37.14 0.92 Level 2 (102-138) 117.68 Level 3 (298-403) 348.99 Coefficient of Variation (%) ie Mean Glucose (mg/dL) ev Glucose Level Ranges (mg/dL) Data generated using the OneTouch Verio Flex™ Meter. 2.05 8.31 2.38 0k 2.41 Pe nd in 51 2.48 PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 108 108 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Detailed information about your system 9 Guarantee ev ie LifeScan guarantees that the OneTouch Verio Flex™ Meter will be free of defects in material and workmanship for three years, valid from the date of purchase. The guarantee extends only to the original purchaser and is not transferable. Electrical and safety standards 51 0k This meter complies with CISPR 11:Class B (Radiated Only). Emissions of the energy used are low and not likely to cause interference in nearby electronic equipment. The meter has been tested for immunity to electrostatic discharge as specified in IEC 61326-2-6. This meter complies with immunity to radio frequency interference as specified in IEC 61326-1 and 61326-2-6. nd in The meter meets the requirements for immunity to electrical interference at the frequency range and test level specified in international standard ISO 15197. Pe Do Not use the equipment where aerosol sprays are being used, or when oxygen is being administered. PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 109 109 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 10 Index Pe nd in 51 0k ev ie AST 41 Batteries 86 86 Batteries, replacing Battery empty icon Battery empty warning 99 Battery low icon 3, 98 BLUETOOTH® SMART feature 7, 11, 29, 71 18 Buttons on meter 82 Cleaning your meter, lancing device and cap Comparing meter results to laboratory results 100 Compatible wireless devices 62 Control solution Control solution, discard and expiration dates 60, 61 Control solution, testing 60, 66, 68 Data port 18 Date setting 26, 28 Dehydration 54, 100 Disinfecting your meter, lancing device and cap 83 Display check 24 Disposal, lancets and test strips 60 Downloading results to a computer 74 Edit date 76 77 Edit range limits Edit time 76 PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 110 110 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin Index 10 Pe nd in 51 PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 111 ie 90 55, 91 54, 90 36 25, 30 109 55, 91 54, 90 3, 4 42 14 14, 41, 43 18, 104 30, 31 33 100, 103 21 77 70 33 25, 28, 76 74 24 ev 0k Error messages EXTREME HIGH GLUCOSE message EXTREME LOW GLUCOSE message Fingertip testing procedure First time setup Guarantee Hyperglycemia Hypoglycemia Icons Infection, reduce the chance Intended use Kit components Lancing device mg/dL Pairing PIN Plasma calibration Range Indicator feature Range limits setting Results, reviewing past Serial number Settings Software, diabetes management Start-up screen 111 1/12/15 10:53 AM Yellow= 5mm Red=7mm margin 10 Index Pe nd in 51 0k ev ie Storing your system 80 Symbols 3, 4 34, 71 Syncing Technical specifications 103 Temperature 36, 68, 80, 92, 93, 104 Test principle Test strip 20, 47, 62 50 Test strip, applying drop of blood 37 Test strip, discard and expiration dates Test strip, silver prongs 20 25, 28 Time setting 35 Turning meter off Turning meter on 24, 47, 62 Unexpected results 54, 56 Unit of measure 18, 104 Unusual red blood cell count (hematocrit) 100, 104 PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 112 112 1/12/15 10:53 AM PF3125983Rev1_OTVF_OB_I_US_en_zug_R4.indd 1 1/12/15 10:54 AM in PMS Spot Colors N/A Language Sequence: English CMYK Black Process Colors N/A CPS Reference No.: Refer to References Section in Enable for CPS No. PF No./Rev.: 3125983 Rev 1 Description: Booklet, Owners, OTVF, US (zug) nd Pe Uncoated Area N/A Uncoated Area 0k 51 ie Special Instructions ev N/A N/A Inside No. of pages: 112 No. of sides: 1 N/A No. of Covers: JDE Item No.: N/A Dieline N/A Dieline Rev. Date: 12-Jan-15 Art Agency: ForeignExchange Translations Job No.: 25677 LFS Contact: Susan Cabral = CUT = SCORE = PERF
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2015:01:12 10:52:51-07:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2015:01:13 16:24:50+01:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2015:01:13 16:24:50+01:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:d35de5c3-4fb0-4698-9926-3154124c97f1 Original Document ID : xmp.did:258273371BBCE111BCD9A90988B2352F Document ID : xmp.id:B2B60CC76E2268118C14B6AC16B6D0B6 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:B1B60CC76E2268118C14B6AC16B6D0B6 Derived From Document ID : xmp.did:CD56697508206811822AFA70EA37DBF7 Derived From Original Document ID: xmp.did:258273371BBCE111BCD9A90988B2352F Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2015:01:12 10:52:52-07:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 118EXIF Metadata provided by EXIF.tools