CipherLab 1260S Bluetooth Wireless Scanner User Manual Table of Contents
CipherLab Co., Ltd. Bluetooth Wireless Scanner Table of Contents
Contents
- 1. users manual
- 2. barcode manual
barcode manual
Table of Contents Restore Default Settings .......................................................................................1 Exit Setup without Changes .................................................................................1 Set Connection.......................................................................................................1 RF Auto Shutdown Duration ...............................................................................1 Memory Mode Parameters...................................................................................2 List Setting.............................................................................................................3 Buzzer Settings ......................................................................................................3 Reading Redundancy Setting ...............................................................................4 Scan Mode Setting.................................................................................................4 Auto-Sense Setting ................................................................................................4 Scanner Time-out Duration..................................................................................5 Negative Barcode Setting .....................................................................................5 Delay between Reread ..........................................................................................5 Keyboard Wedge Parameters ..............................................................................6 Laptop Support .....................................................................................................8 RS-232 Parameters ...............................................................................................9 Bluetooth Serial Port Parameters......................................................................11 Prefix / Postfix Settings.......................................................................................12 Character Substitution .......................................................................................12 Code ID Selection ................................................................................................12 Code ID Setting ...................................................................................................13 Length Code Setting (2 digits)............................................................................14 Select Readable Codes ........................................................................................17 Code39 Parameters .............................................................................................22 Italy Pharmacode Parameters............................................................................22 French Pharmacode Parameters .......................................................................23 Industrial 25 Parameters....................................................................................23 Interleave 25 Parameters....................................................................................24 Matrix 25 Parameters.........................................................................................26 Codabar Parameters...........................................................................................27 Plessey Parameters..............................................................................................28 Telepen Parameters ............................................................................................28 MSI Parameters ..................................................................................................29 MSI Parameters ..................................................................................................29 EAN128 Parameters ...........................................................................................30 EAN8 Parameters ...............................................................................................31 UPCA Parameters...............................................................................................31 UPCE Parameters ...............................................................................................32 EAN13 Parameters .............................................................................................33 RSS Code ID Selection........................................................................................34 RSS14 Parameters...............................................................................................34 RSS Limited Parameters ....................................................................................35 RSS Limited Parameters .................................................................................... 35 Activate Editing Formats ................................................................................... 36 Editing Format Parameters ............................................................................... 37 Decimal Digits ..................................................................................................... 49 Hexadecimal Digits ............................................................................................. 50 RS-232 Character Table..................................................................................... 51 Restore Default Settings Memory Mode Parameters • Memory Mode Exit Setup without Changes Enable < Disable > • Clear Data Set Connection Clear Confirm • Send Data Programming Instructions : (1) Read the label. (2) Read the Serial Number barcode on the bottom of the desired 3660 Base Station within 5 seconds to complete this setting. • Memory Data Delay RF Auto Shutdown Duration <0> Programming Instructions : (1) Read the label. (2) Program the desired auto shutdown duration (in minutes) by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. 2 sec 250 ms 3 sec 500 ms 5 sec 1 sec 8 sec Update Enter Setup List Setting Reading Redundancy Setting Page1 < No Redundancy > Page 6 2 Times Page 2 3 Times 4 Times Page 7 Scan Mode Setting Page 3 Page 8 Auto Off Mode Page 4 < Continuous Mode > Page 9 Auto Power Off Mode Page 5 Alternate Mode Page 10 Buzzer Settings Momentary Mode Repeat Mode < Buzzer Enable> Laser Mode Buzzer Disable Test Mode • Buzzer Frequency Auto-Sense Setting 8 kHz Enable < 4 kHz > < Disable > 2 kHz 1 kHz Update Enter Setup Keyboard Wedge Parameters Scanner Time-out Duration • Activate and Select Keyboard Type Programming Instructions : (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Programming Instructions : (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Negative Barcode Setting • Keyboard Table No. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Enable < Disable > Delay between Reread 100 ms 1 sec 200ms 2 sec < 400 ms > 3 sec 800 ms 5 sec Update Keyboard Type PCAT (US) PCAT (French) PCAT (German) PCAT (Italy) PCAT (Swedish) PCAT (Norwegian) PCAT (UK) PCAT (Belgium) PCAT (Spanish) PCAT (Portuguese) PS55 A01-1 PS55 A01-2 PS55 A01-3 PS55 001-1 PS55 001-81 PS55 001-2 PS55 001-82 PS55 001-3 PS55 001-8A PS55 002-1, 003-1 PS55 002-81, 003-81 PS55 002-2, 003-2 PS55 002-82, 003-82 PS55 002-3, 003-3 PS55 002-8A, 003-8A IBM 3477 (Japanese) PS2-30 IBM 34XX/319X, Memorex Telex 122 Keys Enter Setup • Keyboard Alphabets Layout • Alphabet Transmission < Default Layout > < Case Sensitive > Ignore Case AZERTY • Digits Transmission QWERTZ • Keyboard Digits Layout < Alphanumeric Key > Numeric Key < Default Layout > • Alt Composing Lower Row Upper Row Yes • Keyboard Capital Lock Type < No > • Inter-Character Delay < Default > Shift Lock Programming Instructions : (1) Read the label. (2) Program the desired intercharacter delay by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Capital Lock • Capital Lock Setting Laptop Support Capital Lock ON < Capital Lock OFF > < Disable> Auto Detection Enable Update Enter Setup • Flow Control RS-232 Parameters • Activate RS232 Interface < None > Scanner Ready • Baud Rate Data Ready INV. Data Ready 115200 • Inter-Character Delay 38400 19200 Programming Instructions : (1) Read the label. (2) Program the desired intercharacter delay by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. < 9600 > 4800 2400 1200 300 • Parity Even Odd < No Parity > • Data Bit <8> Update 10 Enter Setup Bluetooth Serial Port Parameters Prefix / Postfix Settings • Activate BlueTooth Serial Port Interface Prefix Code * Postfix Code * • Device Name Broadcasting Character Substitution < Yes > Set 1 * No Set 2 * • Authentication Set 3 * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. Yes < No > • PIN Code Code ID Selection • Clear All Code ID Settings Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. (4) Max 6 characters for this PIN Code setting. • Select Code ID Set Set 1 Set 2 Set 3 Set 4 Set 5 Update 11 12 Enter Setup Code ID Setting Length Code Setting (2 digits) • Code 39 Length Code Code 39 * Enable Italy Pharmacode * < Disable > French Pharmacode * • Italy Pharmacode Length Code Industrial 25 * Interleave 25 * Enable Matrix 25 * < Disable > Codabar * • French Pharmacode Length Code UPCA * UPCE * Enable EAN8 * < Disable > EAN13 * • Industrial 25 Length Code Code 93 * Code 128 * Enable MSI * < Disable > • Interleave 25 Length Code Plessey * Telepen * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. Update 13 Enable < Disable > 14 Enter Setup • Matrix 25 Length Code • Code 93 Length Code Enable Enable < Disable > < Disable > • Code 128 Length Code • Codabar Length Code Enable Enable < Disable > < Disable > • EAN128/RSS Length Code • UPCA Length Code Enable Enable < Disable > < Disable > • MSI Length Code • UPCE Length Code Enable Enable < Disable > < Disable > • Plessey Length Code • EAN8 Length Code Enable Enable < Disable > < Disable > • Telepen Length Code • EAN13 Length Code Enable Enable < Disable > < Disable > Update 15 16 Enter Setup • Matrix 25 Select Readable Codes • Code 39 Enable < Disable > < Enable > • Codabar Disable • Italy Pharmacode < Enable > Disable Enable • Code 93 < Disable > • French Pharmacode < Enable > Disable Enable • Code 128 < Disable > • Industrial 25 < Enable > Disable < Enable > • EAN128 Disable • Interleave 25 Enable < Disable > < Enable > • MSI Disable Enable < Disable > Update 17 18 Enter Setup • Plessey • UPCE Enable < Enable No Addon > < Disable > Disable No Addon • Telepen Enable Addon2 < Disable Addon2 > Enable Enable Addon5 < Disable > • UPCA < Disable Addon5 > • EAN8 < Enable No Addon > Disable No Addon < Enable No Addon > Enable Addon2 Disable No Addon < Disable Addon2 > Enable Addon2 Enable Addon5 < Disable Addon2 > < Disable Addon5 > Enable Addon5 < Disable Addon5 > Update 19 20 Enter Setup Code39 Parameters • EAN13 • Standard / Full ASCII Code39 < Enable No Addon > < Standard > Disable No Addon Full ASCII Enable Addon2 • Start / Stop Transmission < Disable Addon2 > Enable Addon5 Enable < Disable Addon5 > < Disable > RSS14 • Checksum Verification Enable Enable < Disable > • RSS Limited < Disable > • Checksum Transmission Enable < Disable > < Enable > • RSS Expanded Disable Italy Pharmacode Parameters Enable • Checksum Transmission < Disable > < Enable > Disable> Update 21 22 Enter Setup French Pharmacode Parameters • Max / Min Code Length Qualification • Checksum Transmission Select Max / Min Length Qualification < Enable > Max Length * Disable Min Length * Industrial 25 Parameters • Fixed Code Length Qualification • Start / Stop Selection Select Fixed Length Qualification < Industrial 25 > Interleave 25 Fixed Length 1 * Matrix 25 Fixed Length 2 * • Checksum Verification Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Enable Interleave 25 Parameters < Disable > • Start / Stop Selection • Checksum Transmission Industrial 25 < Enable > < Interleave 25 > Disable Matrix 25 Update 23 24 Enter Setup • Checksum Verification • Fixed Code Length Qualification Enable Select Fixed Length Qualification < Disable > • Checksum Transmission Fixed Length 1 * Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. < Enable > Disable • Max / Min Code Length Qualification Matrix 25 Parameters • Start / Stop Selection Select Max / Min Length Qualification Industrial 25 Max Length * Interleave 25 Min Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. < Matrix 25 > • Checksum Verification Enable < Disable > • Checksum Transmission < Enable > Disable Update 25 26 Enter Setup • Max / Min Code Length Qualification • Start / Stop Selection Select Max / Min Length Qualification < abcd / abcd > abcd / tn*e Max Length * ABCD / ABCD Min Length * ABCD / TN*E • Fixed Code Length Qualification Plessey Parameters • Convert to UK Plessey Select Fixed Length Qualification Fixed Length 1 * Enable Fixed Length 2 * < Disable > Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. • Checksum Transmission < Enable > Codabar Parameters Disable • CLSI Conversion Telepen Parameters • Telepen Output Enable < Disable > < AIM Telepen > • Start / Stop Transmission Original Telepen Enable < Disable > Update 27 28 Enter Setup • Fixed Code Length Qualification MSI Parameters • Checksum Verification Select Fixed Length Qualification < Single Modulo 10 > Fixed Length 1 * Double Modulo 10 Fixed Length 2 * Modulo 11 & 10 Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. • Checksum Transmission EAN128 Parameters < Last digit not Transmitted > • Code ID Transmission Transmitted Last 2 Digits not Transmitted • Max / Min Code Length Qualification Enable < Disable > Select Max / Min Length Qualification • Field Separator Max Length * Min Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Update 29 Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. 30 Enter Setup EAN8 Parameters UPCE Parameters • Convert to EAN13 • System Number Selection Enable System Number 0 and 1 < Disable > < System Number 0 only > • Checksum Transmission • Convert to UPCA < Enable > Enable Disable < Disable > • System Number Transmission UPCA Parameters • Convert to EAN13 Enable < Disable > < Enable > • Checksum Transmission Disable • System Number Transmission < Enable > Disable < Enable > Disable • Checksum Transmission < Enable > Disable Update 31 32 Enter Setup EAN13 Parameters RSS Code ID Selection • ISBN Conversion ]C1 Enable < ]e0 > < Disable > RSS14 Parameters • ISSN Conversion • Code ID Transmission Enable < Enable > < Disable > Disable • Checksum Transmission • Application ID Transmission < Enable > < Enable > Disable Disable • Checksum Transmission < Enable > Disable Update 33 34 Enter Setup RSS Limited Parameters Activate Editing Formats • Code ID Transmission • Format 1 < Enable > Enable Disable < Disable > • Application ID Transmission • Format 2 < Enable > Enable Disable < Disable > • Checksum Transmission • Format 3 < Enable > Enable Disable < Disable > • Exclusive Data Editing RSS Limited Parameters • Code ID Transmission Yes < No > < Enable > • Apply Editing Format to Telepen Disable < Yes > No Update 35 36 Enter Setup • Applicable Data Length Editing Format Parameters • Format Selection Maximum Length * Minimum Length * Format 1 Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Format 2 Format 3 • Matching String of Applicable Data • Restore Default Format Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. • Location of Matching String Programming Instructions : (1) Read the label. (2) Program the desired location by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Update 37 38 End of Format Programming • Total Number of Fields • Applicable Code Type All Clear Code 39 Italy Pharmacode French Pharmacode Industrial 25 Interleave 25 Matrix 25 Codebar Code 93 Code 128 EAN128 / RSS UPCE No Addon UPCE Addon2 UPCE Addon5 EAN8 No Addon EAN8 Addon2 EAN8 Addon5 Update 39 40 End of Format Programming • Field1 Setting Divide Field by Field Terminating String EAN13 No Addon EAN13 Addon2 EAN13 Addon5 Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. UPCA No Addon UPCA Addon2 UPCA Addon5 MSI Include Terminating String Plessey Discard Terminating String Divide Field by Field Length Field Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Update 41 42 End of Format Programming • Field2 Setting • Field3 Setting Divide Field by Field Terminating String Divide Field by Field Terminating String Field Terminating String * Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. Include Terminating String Include Terminating String Discard Terminating String Discard Terminating String Divide Field by Field Length Divide Field by Field Length Field Length * Field Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Update 43 44 End of Format Programming • Field4 Setting • Field5 Setting Divide Field by Field Terminating String Divide Field by Field Terminating String Field Terminating String * Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. Include Terminating String Include Terminating String Discard Terminating String Discard Terminating String Divide Field by Field Length Divide Field by Field Length Field Length * Field Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Update 45 46 End of Format Programming • Additional Fields Setting • Field Transmission Sequence Start Additional Field 1 * Additional Field 4 * Field 1 Additional Field 2 * Additional Field 1 Additional Field 5 * Field 2 Additional Field 3 * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. Additional Field 2 Field 3 Additional Field 3 Field 4 Additional Field 4 Field 5 Additional Field 5 Field 6 End Programming Instructions : (1) Read the “Start” label. (2) Program the desired transmission sequence by reading the Field / Additional Field labels. (3) Read the “End” label to complete this setting. Update 47 48 End of Format Programming Decimal Digits Hexadecimal Digits • Validate • Validate Update 49 50 Enter Setup RS-232 Character Table SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE SP DC1 ! DC2 " DC3 # DC4 $ NAK % SYN & ETB CAN ( EM SUB * ESC + FS GS RS US o DEL Update 51
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2003:11:20 17:57:48+08:00 Create Date : 2003:11:20 17:57:15+08:00 Page Count : 27 Creation Date : 2003:11:20 09:57:15Z Mod Date : 2003:11:20 09:57:15Z Producer : Acrobat Distiller 5.0 (Windows) Author : CipherLab Metadata Date : 2003:11:20 09:57:15Z Creator : CipherLab Title : Table of Contents Page Mode : UseNone Tagged PDF : YesEXIF Metadata provided by EXIF.tools