CipherLab 1661 BT Barcode Scanner User Manual 1660 Barcode Scanner

CipherLab Co., Ltd. BT Barcode Scanner 1660 Barcode Scanner

manual

Download: CipherLab 1661 BT Barcode Scanner User Manual 1660 Barcode Scanner
Mirror Download [FCC.gov]CipherLab 1661 BT Barcode Scanner User Manual 1660 Barcode Scanner
Document ID1392203
Application IDZjPw6i3Jt5IpqNj0gYAMnw==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize114.34kB (1429250 bits)
Date Submitted2010-12-17 00:00:00
Date Available2010-12-17 00:00:00
Creation Date2010-12-03 17:01:41
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2010-12-03 17:02:00
Document Title1660 Barcode Scanner
Document CreatorAcrobat PDFMaker 9.1 Word 版
Document Author: Carrie Chen

1660/1661 Barcode Scanner
Setup barcodes included.
Version 1.14
Copyright © 2008~2010 CIPHERLAB CO., LTD.
All rights reserved
The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided
under a license agreement containing restrictions on use and disclosure and is also
protected by copyright law. Reverse engineering of the software is prohibited.
Due to continued product development this information may change without notice. The
information and intellectual property contained herein is confidential between CIPHERLAB
and the client and remains the exclusive property of CIPHERLAB CO., LTD. If you find
any problems in the documentation, please report them to us in writing. CIPHERLAB
does not warrant that this document is error-free.
No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means, electronic, mechanical, photocopying,
recording or otherwise without the prior written permission of CIPHERLAB CO., LTD.
For product consultancy and technical support, please contact your local sales
representative. Also, you may visit our web site for more information.
The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD.
All brand, product and service, and trademark names are the property of their registered
owners.
The editorial use of these names is for identification as well as to the benefit of the
owners, with no intention of infringement.
CIPHERLAB CO., LTD.
Website: http://www.cipherlab.com
IMPORTANT NOTICES
FOR USA
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
 Reorient or relocate the receiving antenna.
 Increase the separation between the equipment and receiver.
 Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
 Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
FOR CANADA
This digital apparatus does not exceed the Class B limits for radio noise emissions from
digital apparatus as set out in the interference-causing equipment standard entitled
"Digital Apparatus," ICES-003 of Industry Canada. This device complies with Part 15 of
the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux
appareils numeriques de Classe B prescrites dans la norme sur le material brouilleur:
"Appareils Numeriques," NMB-003 edictee par l'Industrie.
FOR HAND-HELD PRODUCT WITH RF FUNCTIONS
The 1660/1661 unit (FCC ID: Q3N-1660, Q3N-1661) complies with FCC radiation
exposure limits set forth for uncontrolled environment and meets the FCC radio
frequency (RF) Exposure Guidelines in Supplement C to OET65. The unit has very low
level of RF energy that it is deemed to comply without testing of specific absorption ratio
(SAR).
The 3610 unit (FCC ID: Q3N-3610) complies with FCC radiation exposure limits set forth
for an uncontrolled environment. This equipment should be installed and operated with
minimum distance 20 cm between the radiator & your body. It only operated in
hand-held used. If you only transfer data to Host wirelessly, please keep the minimum
distance 20 cm between machine & your body.
SAFETY PRECAUTIONS
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
 DO NOT disassemble, incinerate or short circuit the battery.
 DO NOT expose the scanner or the battery to any flammable sources.
 For green-environment issue, it's important that batteries should be recycled in a
proper way.
 Under no circumstances, internal components are self-serviceable.
CARE & MAINTENANCE
 Use a clean cloth to wipe dust off the scanning window and the body of the scanner.
DO NOT use/mix any bleach or cleaner.
 If you want to put away the scanner for a period of time, download the collected data
to a host computer when in the memory mode, and then take out the battery. Store
the scanner and battery separately.
 When the scanner resumes its work, make sure the battery is fully charged before
use.
 If you shall find the scanner malfunctioning, write down the specific scenario and
consult your local sales representative.
RELEASE NOTES
Version
Date
Notes
CONTENTS
IMPORTANT NOTICES ............................................................................... - 2 For USA ............................................................................................ - 3 For Canada ........................................................................................ - 3 For Hand-held Product with RF Functions .................................................... - 3 Safety Precautions ............................................................................... - 4 Care & Maintenance ............................................................................. - 4 RELEASE NOTES ..................................................................................... - 4 INTRODUCTION ......................................................................................... 1
Getting Familiarized with 1660/1661 and 3610 .................................................. 2
Installing Batteries to 1660/1661 ............................................................... 2
Charging the Battery for 1661 .................................................................. 3
Charging the Battery via Charger............................................................... 4
Using 3610 ......................................................................................... 5
Inside the Package ................................................................................... 6
Product Highlights.................................................................................... 6
Symbologies Supported .............................................................................. 7
QUICK START ........................................................................................... 9
Enter Configuration Mode ......................................................................... 11
Exit Configuration Mode ........................................................................... 11
Default Settings .................................................................................... 12
Save User Settings as Defaults ................................................................ 12
Restore User Defaults .......................................................................... 12
Restore System Defaults ....................................................................... 12
Read a Setup Barcode ............................................................................. 13
Configure Parameters .......................................................................... 13
List the Current Settings ....................................................................... 17
Create One-Scan Setup Barcodes ................................................................ 19
UNDERSTANDING THE BARCODE SCANNER ....................................................... 21
1.1 Battery .......................................................................................... 21
1.1.1 How to Operate the Scanner ........................................................... 21
1.1.2 Auto Power Off & Power-Saving ....................................................... 23
1.2 Memory.......................................................................................... 26
1.2.1 Transmit Buffer .......................................................................... 26
1.2.2 Memory Mode............................................................................. 27
1.3 LED Indicator ................................................................................... 29
1.3.1 Good Read LED ........................................................................... 30
1.3.2 Good Read LED Duration ................................................................ 30
1.4 Beeper........................................................................................... 31
1.4.1 Beeper Volume ........................................................................... 32
1660 Barcode Scanner User Guide
1.4.2 Good Read Beep ......................................................................... 33
1.4.3 Low Battery Alarm (1660) .............................................................. 34
1.4.4 Low Battery Alarm (1661) .............................................................. 34
1.5 Send “NR” to Host ............................................................................. 35
1.6 Scan Modes ..................................................................................... 36
1.6.1 Continuous Mode ......................................................................... 37
1.6.2 Test Mode ................................................................................. 37
1.6.3 Default mode ............................................................................. 38
1.6.4 Auto Off Mode ............................................................................ 38
1.6.5 Auto Power Off Mode.................................................................... 38
1.6.6 Alternate Mode ........................................................................... 39
1.6.7 Aiming Mode .............................................................................. 39
1.6.8 Multi-Barcode Mode ..................................................................... 40
1.7 Scanning Timeout.............................................................................. 41
1.8 Delay between Re-read ....................................................................... 42
1.9 Read Redundancy for All Symblogies ....................................................... 43
1.10 Addon Security for UPC/EAN Barcodes .................................................... 44
1.11 Negative Barcodes ........................................................................... 45
1.12 Effective Decoding Area ..................................................................... 46
1.12.1 Positioning Window .................................................................... 46
1.12.2 Adjusting Window ...................................................................... 47
SELECTING OUTPUT INTERFACE .................................................................... 49
2.1 BT HID ........................................................................................... 50
2.1.1 Activate BT HID & Select Keyboard Type............................................. 50
2.1.2 Reset Connection ........................................................................ 51
2.1.3 Keyboard Settings ....................................................................... 52
2.1.4 Inter-Function Delay .................................................................... 59
2.1.5 HID Character Transmit Mode .......................................................... 59
2.1.6 Keypad Support for iPhone/iPad ...................................................... 60
2.2 BT SPP Slave .................................................................................... 61
2.2.1 Activate BT SPP Slave Mode ............................................................ 61
2.2.2 Inter-Function Delay .................................................................... 61
2.2.3 ACK/NAK Timeout ....................................................................... 62
2.3 BT SPP Master .................................................................................. 63
2.3.1 Activate BT SPP Master Mode .......................................................... 63
2.3.2 Inter-Function Delay .................................................................... 65
2.3.3 ACK/NAK Timeout ....................................................................... 66
2.3.4 Switch between Master/Slave Mode .................................................. 66
2.4 USB HID via 3610 ............................................................................... 67
2.4.1 Activate USB HID & Select Keyboard Type ........................................... 67
2.4.2 Keyboard Settings ....................................................................... 68
2.4.3 Inter-Function Delay .................................................................... 75
2.4.4 HID Character Transmit Mode .......................................................... 75
2.5 USB Virtual COM via 3610..................................................................... 76
2.5.1 Activate USB Virtual COM ............................................................... 76
2.5.2 Inter-Function Delay .................................................................... 76
2.5.3 ACK/NAK Timeout ....................................................................... 77
1660 Barcode Scanner User Guide
SETTING UP A WPAN CONNECTION ................................................................ 79
3.1 Connecting via 3610 ........................................................................... 80
3.1.1 Connect to 3610 ......................................................................... 80
3.1.2 Change Interface......................................................................... 81
3.1.3 Configure Related Settings ............................................................. 82
3.2 Connecting via Bluetooth® Dongle .......................................................... 83
3.2.1 Change Interface......................................................................... 83
3.2.2 Configure Related Settings ............................................................. 84
3.2.3 Connect to Dongle ....................................................................... 87
SPECIFICATIONS ....................................................................................... 95
INTRODUCTION
CipherLab’s small-form-factor 1660 Series Barcode Scanners are specifically designed to
answer your mobile demands. The palm-sized scanners are designed to help accelerate
productivity while lowering the total cost of ownership. Intensive data collection jobs are
made easier with fast, accurate barcode scanning in various working environments,
especially in small businesses. Integrating short-distance wireless technology to
small-form-factor scanners, the scanners are ideal for carrying in your pocket, and thus
give workers tether-free mobility anytime anywhere and get job done more efficiently.
This line of scanners deliver data over a wireless personal network at a range of up to 10
meters and a prolonged battery life to keep business running.
Owing to the compact design, extremely low power consumption, and powerful decoding
capability, the 1660 Series Barcode Scanners are the best choice for the following
applications –











Receiving in Retail
Product labeling & Tracking
Shelf Product Replenishment
Mobile Point of Sale (POS)
Mobile Inventory Management
Order Picking & Staging
Work-In-Process Tracking
Material Flow Control
Transportation & Distribution
Warehousing
Asset Management
This manual contains information on operating the scanner and using its features. We
recommend you to keep one copy of the manual at hand for quick reference or
maintenance purposes. To avoid any improper disposal or operation, please read the
manual thoroughly before use.
Thank you for choosing CipherLab products!
Update
1660 Barcode Scanner User Guide
GETTING FAMILIARIZED WITH 1660/1661 AND 3610
INSTALLING BATTERIES TO 1660/1661
1) Hold the scanner face down in one hand.
2) Press the battery lid release and slide the battery lid.
3) Remove the battery lid by the other hand.
4) Hold the scanner still and insert the battery or batteries into the battery
compartment.
 For 1660, install two AAA Alkaline batteries into the battery compartment, each in
the right direction.
5) Replace the battery lid and lock it firmly.
6) Hold down the [Power/Delete] key for about 2 seconds to turn on the scanner.
The scanner will respond with a long beep (high tone) and its LED indicator will
become solid red and go off quickly.
Note: (1) To turn off the scanner, press the [Power/Delete] key for 2 seconds. The
scanner will respond with two short beeps (high tone) and the LED will finally
become solid red. Release the key then. Otherwise, let the scanner turn off
automatically in specific circumstances. Refer to settings of “Auto Power Off”.
(2) For shipping and storage purposes, save the scanner and the batteries
separately. This will keep the batteries in good condition for future use.
Enter Setup
錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
CHARGING THE BATTERY FOR 1661
The battery may not be charged to full for shipment. When you first receive the package,
you will need to charge the battery to full before using the scanner. For 1661, use the
Direct USB cable to connect the scanner to PC for charging.
Note: Battery charging stops when the temperature drops below 0°C or exceeds 40°C. It
is recommended to charge the battery at room temperature (18°C to 25°C) for
optimal performance. It takes approximately 4 hours to charge the battery to full.
1) Install the battery to 1661.
2) Connect 1661 to your computer or notebook via the USB cable.
3) The scanner LED will be flashing red during charging.
When the charging is done, the LED will turn off.
When charging error occurs, the LED will turn solid red.
Update
1660 Barcode Scanner User Guide
CHARGING THE BATTERY VIA CHARGER
The battery charger is provided for charging the battery only. You may purchase the
charger separately.
Note: Battery charging stops when the temperature drops below 0°C or exceeds 40°C. It
is recommended to charge the battery at room temperature (18°C to 25°C) for
optimal performance. It takes approximately 3 hours to charge the battery to full.
1) Insert the battery.
2) Connect the power supply cord to the charger.
3) Connect the other end of the power cord to a suitable power outlet.
Status LED
Meaning
Red,
solid
---
Charger power ON (LED on for 0.5 second)
Red,
solid
---
Charging battery
---
Green,
solid
Charging done
Red,
solid
Green,
solid
Pre-charging when battery voltage under 3V (Typical)
---
---
Power or battery not ready
Enter Setup
錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
USING 3610
The BT Transponder (3610) is specifically designed for the scanner to communicate with
a host computer wirelessly. The connection between the scanners and 3610 is made easy
and reliable. Refer to 3.1.1 Connect to 3610.
There is one LED indicator provided for communications status.
Communication LED
Meaning
---
Blue,
solid
Initialize
Red,
solid
---
Failed to establish a USB connection
Red,
solid
Blue,
flashing
Serial command mode with USB Virtual COM: wait 3 seconds for starting a
serial command
Red,
flashing
Blue,
flashing
Serial command mode with USB HID: wait 3 seconds for pressing [Num
Lock] or [Caps Lock] 5 times via keyboard
---
Blue,
flashing
Wait for connection request from the scanner (Slow flash at 0.5 Hz)
---
Blue,
flashing
Connected with the scanner (Fast flash at 1 Hz)
Red,
solid
Blue,
flashing
Failed to send data to host via USB Virtual COM (Fast flash at 1 Hz)
Red,
flashing
---
Enter Download Mode
Update
1660 Barcode Scanner User Guide
INSIDE THE PACKAGE
The items included in the package may be different, depending on your order. Save the
box and packaging material for future use in case you need to store or ship the scanner.





Barcode Scanner (1660 or 1661)
BT Transponder (3610)
Rechargeable Li-ion battery (for 1661)
Direct USB Cable (for 1661)
Product CD
Note: The CD-ROM includes this manual and Windows-based ScanMaster software for
configuration, as well as the USB Virtual COM driver.
PRODUCT HIGHLIGHTS









Small-form-factor and built tough to survive drop test
Extremely low power consumption
Firmware upgradeable
Supports most popular barcode symbologies, including GS1-128 (EAN-128), GS1
DataBar (RSS), etc.
Supports negative barcodes
Supports different scan modes, including Aiming Mode and Multi-Barcode Mode
User feedback via LED indicator and beeper
Beeping tone and duration programmable for Good Read
256 KB flash memory for Memory Mode operation, storing up to 16,384 scans based
on EAN-13 barcodes
 Provides up to 1 KB SRAM for reserve buffer while getting out of range over a
wireless personal area network (WPAN), storing up to 64 scans based on EAN-13
barcodes
 Capable of transmitting scanned data, emulating a serial cable (BT SPP) or as
keyboard input (BT HID), to a notebook computer or PDA with Bluetooth® wireless
technology
 Supports BT SPP Slave & Master Mode operations
 Programmable parameters include data output format, editing format, symbologies,
etc.
Enter Setup
錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
SYMBOLOGIES SUPPORTED
Most of the popular barcode symbologies are supported, as listed below. Each can be
individually enabled or disabled. The scanner will automatically discriminate and
recognize all the symbologies that are enabled. Refer to Chapter 4 Changing Symbology
Settings for details of each symbology.
Symbologies Supported: Enable/Disable
Default
Codabar
Enabled
Code 93
Enabled
MSI
Disabled
Plessey
Disabled
Telepen
Disabled
Code 128
Code 128
Enabled
GS1-128 (EAN-128)
Code 2 of 5
Disabled
ISBT 128
Enabled
Industrial 25
Enabled
Interleaved 25
Enabled
Matrix 25
Code 3 of 9
EAN/UPC
Code 39
Disabled
Enabled
Italian Pharmacode
Disabled
French Pharmacode
Disabled
EAN-8
Enabled
EAN-8 Addon 2
Disabled
EAN-8 Addon 5
Disabled
EAN-13
Enabled
EAN-13 & UPC-A Addon 2
Disabled
EAN-13 & UPC-A Addon 5
Disabled
ISBN
Disabled
UPC-E0
Enabled
UPC-E1
Disabled
UPC-E Addon 2
Disabled
UPC-E Addon 5
Disabled
UPC-A
Enabled
Update
1660 Barcode Scanner User Guide
GS1 DataBar
(RSS)
GS1 DataBar Omnidirectional (RSS-14)
Disabled
GS1 DataBar Truncated
Disabled
GS1 DataBar Stacked
Disabled
GS1 DataBar Stacked Omnidirectional
Disabled
GS1 DataBar Limited (RSS Limited)
Disabled
GS1 DataBar Expanded (RSS Expanded)
Disabled
GS1 DataBar Expanded Stacked
Disabled
Enter Setup
QUICK START
The configuration of the scanner can be done by reading the setup barcodes contained in
this manual or via the ScanMaster software.
This section describes the procedure of configuring the scanner by reading the setup
barcodes and provides some examples for demonstration.
Configuration Mode
1.
Hold down the [Power/Delete] key for about 2 seconds to turn on the scanner. It will respond
with a long beep and its LED will come on-off shortly.
2.
Have the scanner read the “Enter Setup” barcode. It will respond with six beeps and its LED
indicator will become flashing red after reading the barcode.
3.
Have the scanner read more setup barcodes… Most of the setup barcodes are normal, and the
scanner will respond with two beeps (low-high tone). For special setup barcodes, it requires
reading more than one setup barcode to complete the setting.
4.
Have the scanner read the “Update” or “Abort” barcode. It will respond with six beeps and its
LED indicator will become flashing red after reading the barcode.
5.
The scanner will restart automatically upon reading the “Update” or “Abort” barcode. It will
respond with a long beep and its LED will come on-off shortly.
Note: Refer to Appendix II Host Serial Commands for how to configure the 3610 dongle
by having the scanner read 3610-related setup barcodes or using serial
commands.
Update
1660 Barcode Scanner User Guide
Working Mode
Upon powering up, the scanner will try to establish a connection with 3610 or a computer with
Bluetooth® wireless technology. Refer to Chapter 3 – Setting up a WPAN Connection for details.
The connection between the scanners and 3610 is made easy and reliable. Now, it also supports
BT SPP Master Mode as an alternative. Refer to 2.3 BT SPP Master.
Note: If USB Virtual COM or BT SPP is selected for output interface, the host can directly
send serial commands to configure the scanner. For example, run
HyperTerminal.exe and type the 6-digit command located under each setup
barcode. Refer to Appendix II Host Serial Commands.
10
Enter Setup
錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
ENTER CONFIGURATION MODE
For the scanner to enter the configuration mode, you must have it read the "Enter Setup"
barcode, which can be located at the bottom of almost every even page of this manual.
 The scanner will respond with six beeps and its LED indicator will become flashing red
after reading the barcode.
Enter Setup
For configuring scanner parameters, see “Read a Setup Barcode” below.
EXIT CONFIGURATION MODE
For the scanner to save settings and exit the configuration mode, you must have it read
the “Update” barcode, which can be located at the bottom of almost every odd page of
this manual. If you want to exit the configuration mode without saving any changes,
have the scanner read the “Abort” barcode instead.
 Just like reading the “Enter Setup” barcode, the scanner will respond with six beeps
and its LED indicator will become flashing red after reading the barcode. Wait for a
few seconds for the scanner to restart itself.
Update
Abort
11
Update
1660 Barcode Scanner User Guide
DEFAULT SETTINGS
SAVE USER SETTINGS AS DEFAULTS
For the scanner to keep the customized settings as user defaults, you must have it read
the “Save as User Defaults” barcode. This is a normal setup barcode, and the scanner will
respond with two beeps (low-high tone).
 After reading the “Update” barcode, the current settings will be saved as user
defaults.
Save as User
Defaults
RESTORE USER DEFAULTS
For the scanner to restore the user defaults, which you have saved earlier, you must
have it read the “Restore User Defaults” barcode. This is a normal setup barcode, and the
scanner will respond with two beeps (low-high tone).
 After reading the “Update” barcode, all the parameters of the scanner will return to
their customized values.
Restore User
Defaults
RESTORE SYSTEM DEFAULTS
For the scanner to restore the factory defaults, you must have it read the “Restore
System Defaults” barcode. This is a normal setup barcode, and the scanner will respond
with two beeps (low-high tone). After reading the “Update” barcode, all the parameters
of the scanner will return to their default values. The current connection record will be
cleared as well. Refer to 1.1.1 How to Operate the Scanner for the key combination used
to restore defaults during operation.
For 3610 to restore factory defaults, refer to 3610 Setup Barcodes & Serial Commands.
Restore System
Defaults
Note: The system default value (if there is) for each setting is indicated by an asterisk
“*”.
12
Enter Setup
錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
READ A SETUP BARCODE
CONFIGURE PARAMETERS
For most of the scanner parameters, only one read is required to set them to new values.
The scanner will respond with two beeps (low-high tone) when each parameter is set
successfully. Refer to Create One-Scan Setup Barcodes.
But for a number of special parameters, multiple reads are required to complete the
setting. In this case, the scanner will respond with a short beep to indicate it needs to
read more setup barcodes. These special parameters may require reading one or more
setup barcodes, such as
 Numeric barcodes, say, for keyboard type, inter-character delay, length qualification
 Hexadecimal barcodes, say, for character strings as prefix, suffix, etc.
 When “BT HID” or “USB HID” is configured for interface, Key Type and Key Status will
then become applicable. You may decide whether or not to change key status when
“Normal Key” is selected for Key Type.
To complete the configuration of these special parameters, it requires reading the
“Validate” barcode, and the scanner will respond with two beeps (low-high tone) to
indicate the input values are validated.
13
Update
1660 Barcode Scanner User Guide
The example below shows how to save your settings as “User Default” so that you may
restore user defaults at a later time:
Steps
Action
User Feedback if Successful
Power on the scanner…
The scanner will respond with a long beep
(high tone) and its LED indicator will
become solid red and go off quickly.
Enter the Configuration Mode…
The scanner will respond with six beeps
(high-low tone repeats three times), and
its LED indicator will be flashing red.
Read a Setup barcode…
The scanner will respond with two beeps
(low-high tone) if reading a normal setup
barcode.
For example,
Exit the Configuration Mode…
Same as for Enter the Configuration Mode.
OR
The scanner will automatically restart itself…
Same as for Power on the scanner.
When any configuration error occurs...
The scanner will respond with one long
beep (low tone).
14
Enter Setup
錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
The example below shows how to set numeric parameters:
Steps
Action
User Feedback if Successful
Power on the scanner...
The scanner will respond with a long beep
(high tone) and its LED indicator will
become solid red and go off quickly.
Enter the Configuration Mode…
The scanner will respond with six beeps
(high-low tone repeats three times), and
its LED indicator will become flashing red.
Read a Setup barcode...
The scanner will respond with two beeps
(low-high tone) if reading a normal setup
barcode.
For example,
Normal setup
barcode
Normal setup
barcode
The scanner will respond with one short
beep if reading a special setup barcode
such as “Max. Length”, indicating the
setup requires reading more barcodes.
Special setup
barcode
Read the “Decimal Value” barcode(s).
Decimal barcodes

Refer to
System”
Appendix
IV
“Decimal
The scanner will respond with two beeps
(low-high tone) when the input values are
validated.
Exit the Configuration Mode…
Same as for Enter the Configuration Mode.
OR
The scanner will automatically restart itself…
Same as for Power on the scanner.
15
Update
1660 Barcode Scanner User Guide
The example below shows how to set string parameters:
Steps
Action
User Feedback if Successful
Power on the scanner...
The scanner will respond with a long beep
(high tone) and its LED indicator will
become solid red and go off quickly.
Enter the Configuration Mode…
The scanner will respond with six beeps
(high-low tone repeats three times), and
its LED indicator will become flashing red.
Read a Setup barcode...
The scanner will respond with one short
beep if reading a special setup barcode
such as “Prefix Code”, indicating the setup
requires reading more barcodes.
For example,
Special setup
barcodes
When “BT HID” or “USB HID” is configured
for interface, Key Type and Key Status will
then become applicable. You may decide
whether or not to change key status when
“Normal Key” is selected for Key Type.

Refer to Appendix III
Read the “Hexadecimal Value” barcodes
for the desired character string. For
example, read “2” and “B” for the scanner
to prefix the character “+”.
Hexadecimal
barcodes

Refer to Appendix IV “Hexadecimal
System”
The scanner will respond with two beeps
(low-high tone) when the input values are
validated.
Exit the Configuration Mode…
Same as for Enter the Configuration Mode.
OR
The scanner will automatically restart itself…
Same as for Power on the scanner.
16
Enter Setup
錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
LIST THE CURRENT SETTINGS
The current settings of all scanner parameters can be sent to the host computer for user
inspection. The listing includes pages as shown below. You can select the page of interest
by having the scanner read the “List Page x” barcode. The scanner will respond with two
beeps (low-high tone) and send the selected page to the host immediately.
List settings regarding Firmware Version, Serial
Number, Interface, Buzzer, and Other Scanner
Parameters
List settings regarding Prefix, Suffix, and Length
Code Setting
List Page 1
List Page 2
List settings regarding Code ID
List Page 3
List settings regarding: Readable Symbologies
List Page 4
List settings regarding Symbology Parameters
(1/3)
List Page 5
List settings regarding Symbology Parameters
(2/3)
List Page 6
List settings regarding Symbology Parameters
(3/3)
List Page 7
List settings regarding Editing Format 1
List Page 8
List settings regarding Editing Format 2
List Page 9
List settings regarding Editing Format 3
List Page 10
17
Update
1660 Barcode Scanner User Guide
List settings regarding Editing Format 4
List Page 11
List settings regarding Editing Format 5
List Page 12
18
Enter Setup
錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
CREATE ONE-SCAN SETUP BARCODES
The fact is most of the scanner parameters require only one read for setting new values.
To facilitate configuring the scanner, you may create One-Scan setup barcodes for use.
The requirements of a One-Scan setup barcode are:
 a prefix of the “#@” characters
 the six digits of command parameters
 a suffix of the “#”character
For example, the scanner needs reading three setup barcodes for the command
parameter “109952” to take effect:
Enter Setup
List Page 3
Update
Now, it requires only one read:
One-Scan Setup Barcode
for 109952
Note: The scanner will restart automatically upon reading the One-Scan setup barcode
for (1) changing the interface or (2) setting memory mode, enable or disable. It
will respond with a long beep and its LED will come on-off shortly.
19
Update
1660 Barcode Scanner User Guide
20
Enter Setup
Chapter 1
UNDERSTANDING THE BARCODE SCANNER
This chapter explains the features and usage of the barcode scanner.
IN THIS CHAPTER
1.1 Battery ...................................................................... 21
1.2 Memory ..................................................................... 26
1.3 LED Indicator ............................................................. 29
1.4 Beeper....................................................................... 31
1.5 Send "NR" to Host ....................................................... 35
1.6 Scan Modes ................................................................ 36
1.7 Scanner Time-out ....................................................... 41
1.8 Delay between Re-read................................................ 42
1.9 Read Redundancy for All Symblogies ............................. 43
1.10 Addon Security for UPC/EAN Barcodes ......................... 44
1.11 Negative Barcodes..................................................... 45
1.12 Effective Decoding Area ............................................. 46
1.1 BATTERY
The scanner is battery-powered: 1660 uses two AAA Alkaline batteries, while 1661 uses
a rechargeable 3.7 V/850 mAh Li-ion battery. For intensive data collection, you may
prepare spare battery or batteries for non-stop operation.
Note: (1) The rechargeable battery for 1661 may not be charged to full for shipment. We
suggest charging it to full before use.
(2) The scanner can be configured to save battery power. Refer to settings of
“Auto Power Off & Power-Saving”, “Sniff Mode”, as well as “Low Battery Alarm”.
1.1.1 HOW TO OPERATE THE SCANNER
Turn on the scanner…
Press the [Power/Delete] key for about 2 seconds. The scanner will respond with a long beep (high
tone), and its LED indicator will become solid red and go off quickly.
Turn off the scanner…
Press the [Power/Delete] key for about 2 seconds. The scanner will respond with two short beeps
(high tone) and the LED will finally become solid red. Release the key then. Otherwise, let the
scanner turn off automatically in specific circumstances.
21
Update
1660 Barcode Scanner User Guide
Delete the last collected data when in memory mode …
Press the [Power/Delete] key. The scanner will respond with two short beeps (high tone) and the
LED will become solid red. Before the LED goes off (within 1 second), press the [Power/Delete] key
again to confirm the deletion.
Note: For the scanner to restore system defaults during operation, use key combination
in the following sequence: Hold down the [Power/Delete] key until its LED
indicator becomes solid red, and without releasing the key, you must press the
[Trigger] key simultaneously for 3 seconds. Then, the scanner will respond with a
long beep (high tone), and the indicator will go off.
22
Enter Setup
Chapter 1
1.1.2 AUTO POWER OFF & POWER-SAVING
The scanner will stay active at power-on, which may be followed by a transition from full
CPU speed to low CPU speed (Power-Saving) to auto shutdown (Auto Power Off).
 Power-Saving (1~254 min.; 0= Disable): By default, it is set to stand by at full-speed
for 2 minutes before it enters low-speed mode. If this feature is not desired, set it to
0.
 Auto Power Off (1~254 min.; 0= Disable): By default, it is set to automatically shut
down after 10 minutes. If this feature is not desired, set it to 0.
Note: The Power-Saving setting will not take effect when a WPAN connection has been
established successfully, via BT HID or SPP.
Before establishing a WPAN connection successfully…
1.
The scanner will stay active for a specified period of time (2 minutes by default) for the
following scenarios. Its CPU is running at full speed, and the LED is flashing blue (On/Off ratio
0.5 s: 0.5 s).
(a) waiting for a connection request from the host (BT SPP Slave Mode)
(b) trying to connect to the host (BT HID or BT SPP Master Mode)
(c) trying to connect to 3610
2.
If it fails to connect within 2 minutes, the scanner will become inactive to save power for the
remaining period of time (the specified value minus 2 minutes). Its CPU is running at low
speed, and the LED is flashing red (On/Off ratio 0.3 s: 2.5 s).
Press the [Trigger] key to wake up the scanner when it becomes inactive, and the scanner will
stay active again.
3.
If it fails to connect again and again, and finally stays inactive until the specified time interval
for Auto Power Off has elapsed, the scanner will automatically turn off in order to conserve
battery power.
Hold down the [Power/Delete] key for about 2 seconds to turn it on.
Note: For scenarios (a) and (b) in step 1, on your computer you may need to search for
the scanner again.
23
Update
1660 Barcode Scanner User Guide
After establishing a WPAN connection successfully…
1.
Once a WPAN connection is established successfully, the scanner will stay active for a specified
period of time (2 minutes by default) for data transmission. Its CPU is running at full speed,
and the LED is flashing blue (On/Off ratio 0.02 s: 3 s).
2.
If it is idle within 2 minutes, the scanner will become inactive to save power for the remaining
period of time (the specified value minus 2 minutes). Its CPU is running at low speed, and the
LED is flashing red (On/Off ratio 0.3 s: 2.5 s).
Press the [Trigger] key to wake up the scanner when it becomes inactive, and the scanner will
stay active again.

3.
For BT HID or SPP, there is no transition from full CPU speed to low CPU speed. However,
when connecting with 3610, the scanner will go through the transition in order to save
power.
If it is idle and finally stays inactive until the specified time interval for Auto Power Off has
elapsed, the scanner will automatically turn off in order to conserve battery power. You will
hear three short beeps, tone descending from high to low.
Hold down the [Power/Delete] key for about 2 seconds to turn it on.

For BT HID, the scanner will resume connection with the host upon powering on again, as
long as the host application is running. You will hear three short beeps, tone ascending
from low to high. If the scanner fails to resume connection, it will try every 5 seconds to
re-connect to the host unless you have the scanner read the “Reset Connection” barcode.


For BT SPP Slave Mode, the scanner must wait for the host to re-connect.

For BT SPP Master Mode, the scanner will resume connection with the host upon powering
on again, as long as the host application is running. You will hear three short beeps, tone
ascending from low to high. If the scanner fails to resume connection, it will try every 5
seconds to re-connect to the host unless you have the scanner read the “Reset
Connection” or “Restore System Defaults” barcode.
With the use of 3610, the scanner will try re-connecting to 3610 unless you turn off the
scanner.
24
Enter Setup
Chapter 1
Auto Off after
0~254 min. (*10)
1) Read the barcode above to specify the time interval before the scanner automatically
turns off.
2) Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. For example, read “1”
and “5” for the scanner to automatically turn off after being idle for 15 minutes.
3) Read the “Validate” barcode on the same page to complete this setting.
Note: Auto Power Off will not take effect when the scanner is in the configuration mode.
Power-Saving after
0~254 min. (*2)
1) Read the barcode above to specify the time interval before the scanner enters
low-speed mode.
2) Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. For example, read “5”
for the scanner to enter low-speed mode after being idle for 5 minutes.
3) Read the “Validate” barcode on the same page to complete this setting.
Note: Power-Saving will not take effect when one of the following conditions is met:
(1) the scanner has already established a BT HID/SPP connection,
(2) the scanner is in the configuration mode,
(3) the scan mode is set to Test, Continuous or Alternate Mode, or
(4) the setting value of Power-Saving is greater than that of Auto Power Off.
25
Update
1660 Barcode Scanner User Guide
1.2 MEMORY
The collected data can be sent back to a host computer one by one via the WPAN
connection or stored in flash memory when the scanner is set to Memory mode.
1.2.1 TRANSMIT BUFFER
By default, transmit buffer is enabled and for use when the scanner is out of range. Upon
reading a barcode successfully within range, the scanner responds with one short beep
(high tone) and its LED indicator becomes solid green and goes off quickly. However, the
host computer may not receive the data immediately if getting out of range. With the 1
KB transmit buffer, the scanner can ignore the transmission status and keep on reading
barcodes until the buffer is full.
When transmit buffer is enabled…
If the scanner is out of range, it will respond with two short beeps, high-low tone, upon reading a
barcode successfully.
When transmit buffer is full, the scanner will respond with one long beep (low tone) and its LED
indicator will become solid red and go off quickly. You are advised to get back to range.
When transmit buffer is disabled…
If the scanner is out of range, it will respond with one long beep (low tone) and its LED indicator
will become solid red and go off quickly. You are advised to get back to range.
*Enable
Disable
Note: The 1 KB transmit buffer on the scanner can hold as many as 64 scans based on
EAN-13 barcodes. Data will be cleared out once the scanner is turned off or
running out of battery power!
26
Enter Setup
Chapter 1
1.2.2 MEMORY MODE
The scanner keeps 256 KB flash memory for memory mode operation. When the scanner
is in memory mode, it means any connection established with host is disabled.
Enable
*Disable
Warning:
No connection is allowed unless the memory mode is disabled.
Memory Data Delay
You may set a delay between each data record while transmitting data back to the server.
*None
250 ms
500 ms
1 sec
2 sec
3 sec
5 sec
27
Update
1660 Barcode Scanner User Guide
8 sec
Send Data
The 256 KB flash memory on the scanner can store up to 16,384 scans based on EAN-13 barcodes.
When it is used up, the scanner will respond with two short beeps (high-low tone) as a warning.
You are advised to send data to the server immediately by having the scanner read the “Send
Data” barcode below. It will resume connection with host automatically.
Send Data
Clear Data & Confirm
Even though data has been sent back to the server, the flash memory is still occupied unless you
erase the memory by having the scanner read two barcodes – “Clear Data” and “Confirm”.
1.
Read the “Clear Data” barcode to clear the flash memory.
2.
Read the “Confirm” barcode to confirm the action.
Clear Data
Confirm
28
Enter Setup
Chapter 1
1.3 LED INDICATOR
The triple-color LED on top of the scanner is used to provide user feedback. For example,
the LED becomes solid red and goes off quickly upon powering on or running out of
transmit buffer. You may tell the difference by the beeps – you will hear a long beep of
high tone when powering on the scanner, and a long beep of low tone when the transmit
buffer becomes full.
Scanner LED
Red,
on-off
Red,
flashing
---
---
Meaning
---
---

Power on, with one long beep (high tone, LED on for 1
second)

Data saved to buffer when transmit buffer is enabled and the
scanner is out of range, with two short beeps (high-low tone)



Transmit buffer full, with one long beep (low tone)

Memory full in memory mode, with two short beeps (high-low
tone)

Flashing red (On/Off ratio 0.3 s: 2.5 s) indicates the scanner
is inactive and its CPU running at low speed to save power
(because no WPAN connection is established after waiting for
two minutes)

Configuration Mode (On/Off ratio 0.5 s: 0.5 s)
Transmit buffer disabled, with one long beep (low tone)
Delete the last collected data in memory mode, with two
short beeps (high tone, LED on for 1 second)
---
---
Green,
on-off
Good Read, with one short beep (high tone) and beeper pitch and
duration programmable
---
Blue,
flashing
---
First, flashing blue (On/Off ratio 0.5 s: 0.5 s) for two minutes
indicates the scanner is waiting for connection, and goes off if no
connection is established, then flashing red (On/Off ratio 0.3 s:
2.5 s) indicates the scanner is inactive.
It is ready for connection only while the LED is flashing blue —



SPP Slave: waiting host to connect
HID or SPP Master: trying to connect to host
Using 3610: trying to connect to 3610
---
Blue,
flashing
---
Flashing blue (On/Off ratio 0.1 s: 0.1 s) indicates the scanner
receives a PIN code request from host (flashing more quickly
than waiting connection).
---
Blue,
flashing
---
Flashing blue (On/Off ratio 0.02 s: 3 s) indicates the scanner has
established a WPAN connection successfully.
---
Blue,
flashing
Green,
flashing
Flashing blue and green (On/Off ratio 0.1 s: 0.1 s) indicates an
error occurs while entering the PIN code. Press the [Trigger] key
to get ready for re-connecting.
29
Update
1660 Barcode Scanner User Guide
1.3.1 GOOD READ LED
*Enable
Good Read LED
Disable
Good Read LED
1.3.2 GOOD READ LED DURATION
By default, the Good Read LED stays on for 40 milliseconds. Specify a value, ranging
from 1 to 254 in units of 10 milliseconds.
Good Read LED
Time-out after
0.01~2.54 sec.
(*40 ms)
1) Read the barcode above to specify the time interval before the Good Read LED goes
off.
2) Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. For example, read “1”
and “5” for the Good Read LED to go off after 150 milliseconds.
3) Read the “Validate” barcode on the same page to complete this setting.
30
Enter Setup
Chapter 1
1.4 BEEPER
The scanner has a buzzer to provide user feedback in various operating conditions.
Beeping
Meaning
One long beep, high tone
Power on, with red LED on (1 second) and off quickly
two short beeps, high tone


One short beep, high tone

Delete the last collected data in memory mode, with red
LED on (1 second) and off quickly
Good Read, with green LED on-off quickly
Programmable, default to 4 KHz
Six short beeps

Power off, with red LED on (until the key is released)
High-low
times
tone
repeats
three


Enter Configuration Mode, with red LED flashing
Exit Configuration Mode
Two short beeps, low-high tone
Setup barcode read successfully
One short beep, high tone



More setup barcode required
Input PIN code
Clear PIN code
One short beep, low tone
More barcodes required to complete the “output sequence”
requirements of Multi-Barcode Editor, with green LED on-off
quickly (Upon completion, same as Good Read.)
One long beep, low tone







Transmit buffer full, with red LED on-off quickly

Memory Mode – Memory full, with red LED on-off quickly
Two short beeps, high-low tone
Transmit buffer disabled, with red LED on-off quickly
Configuration error (Wrong barcode…)
PIN code input error
Reject random PIN request
Fail to send data in memory mode
Data saved to buffer when transmit buffer is enabled
and the scanner is out of range, with red LED on-off
quickly
Two short beeps, high tone
Low Battery Alarm
Two long beeps, high-low tone
Multi-Barcode Mode – Buffer full
Three short beeps, tone ascending
from low to high


Three short beeps, tone ascending
from high to low
WPAN connection out of range or suspended
WPAN connection established, with blue LED flashing
WPAN connection resumed, with blue LED flashing
31
Update
1660 Barcode Scanner User Guide
1.4.1 BEEPER VOLUME
Mute
Minimum Volume
Medium Volume
*Maximum Volume
32
Enter Setup
Chapter 1
1.4.2 GOOD READ BEEP
Frequency
8 kHz
*4 kHz
2 kHz
1 kHz
Duration
*Shortest
Shorter
Longer
Longest
33
Update
1660 Barcode Scanner User Guide
1.4.3 LOW BATTERY ALARM (1660)
By default, “2.6 V (Alkaline)” is selected for low battery level. When the battery level
inside the 1660 scanner reaches 2.6 V, it will activate the beeper to give a warning. If
you are using Ni-MH batteries, select “2.1 V (Ni-MH)”. In order to prevent data loss, you
are advised to replace the batteries immediately when you hear two short beeps (high
tone).
No Alarm
*2.6 V (Alkaline)
2.1 V (Ni-MH)
Note: Ni-MH batteries available in retail stores can be used to replace the two AAA
Alkaline batteries.
1.4.4 LOW BATTERY ALARM (1661)
By default, it will activate the beeper to give a warning when the battery charge gets low.
In order to prevent data loss, you are advised to replace the battery immediately when
you hear two short beeps (high tone).
No Alarm
*Low Battery Alarm
34
Enter Setup
Chapter 1
1.5 SEND “NR” TO HOST
The scanner can send the “NR” string to the host to notify the No Read event.
Enable
*Disable
35
Update
1660 Barcode Scanner User Guide
1.6 SCAN MODES
Different scan modes are supported – select the scan mode that best suits the
requirements of a specific application. Refer to the comparison table below.
Scan Mode
Start to Scan
Always
Continuous
mode

Test mode

Press
trigger
once
Stop Scanning
Hold
trigger

Default mode
Auto Off mode

Auto Power Off
mode

Alternate mode

Release
trigger
Press
trigger
once

Barcode
being
read
Timeout







Aiming mode
Multi-Barcode
mode
Press
trigger
twice



Note: By default, the scan mode is set to Default mode.
36
Enter Setup

Chapter 1
1.6.1 CONTINUOUS MODE
The scanner is always scanning.
 After a successful decoding, the removal of barcode is required. It is not allowed to
proceed to decode until the decoding delay time has passed.
 To decode the same barcode repeatedly, move away the barcode and put it back
again and again for scanning.
Note: Refer to “Delay between Re-read”.
Continuous Mode
Decoding Delay
Set the time interval between each decoding.
*Disable
0.5 sec
1 sec
2 sec
1.6.2 TEST MODE
The scanner is always scanning.
 Capable of decoding the same barcode repeatedly without removing it, for testing
purpose.
Test Mode
37
Update
1660 Barcode Scanner User Guide
1.6.3 DEFAULT MODE
The scanner will start scanning once the trigger is held down.
 The scanning won't stop until (1) a barcode is decoded, (2) the pre-set timeout
expires, or (3) you release the trigger.
Note: Refer to “Scanning Timeout”.
*Default mode
1.6.4 AUTO OFF MODE
The scanner will start scanning once the trigger is pressed.
 The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout
expires.
Note: Refer to “Scanning Timeout”.
Auto Off Mode
1.6.5 AUTO POWER OFF MODE
The scanner will start scanning once the trigger is pressed.
 The scanning won't stop until the pre-set timeout expires, and, the pre-set timeout
period re-counts after each successful decoding.
Note: Refer to “Delay between Re-read” and “Scanning Timeout”.
Auto Power Off Mode
38
Enter Setup
Chapter 1
1.6.6 ALTERNATE MODE
The scanner will start scanning once the trigger is pressed
 The scanning won't stop until you press the trigger again.
Alternate Mode
1.6.7 AIMING MODE
The scanner will aim at a barcode once the trigger is pressed, and start scanning when
the trigger is pressed again within one second.
 The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout
expires.
Aiming Mode
Aiming Timeout
You can limit the aiming time interval (1~15). By default, the scanner time-out is set to 1 second.
Aiming Time-out
after 1~15 sec.
(*1)
1.
Read the barcode above to specify the time interval before aiming ends. (It is set to 1 by
default.)
2.
Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. For example, read “1” and “0”
for the scanner to automatically shut down after being idle for 10 seconds.
3.
Read the “Validate” barcode on the same page to complete this setting.
39
Update
1660 Barcode Scanner User Guide
1.6.8 MULTI-BARCODE MODE
The scanner will be scanning as long as the trigger is held down, capable of decoding one
single barcode, as well as a multiple unique barcodes one at a time. While decoding a
bunch of unique barcodes, if a barcode is decoded twice, its subsequent decoding will be
ignored and the scanner is expecting another unique barcode.
 The scanning won't stop until you release the trigger.
Multi-Barcode Mode
Note: (1) A barcode is considered unique when its Code Type or data is different from
others.
(2) Multi-Barcode Mode has nothing to do with the Multi-Barcode Editor.
40
Enter Setup
Chapter 1
1.7 SCANNING TIMEOUT
Specify the scanning time interval (1~254 sec.; 0= Disable) when the scan mode is set
to any of the following –




Default mode
Auto Off mode
Auto Power Off mode
Aiming mode
Scanner Time-out
after 0~254 sec.
(*10)
1) Read the barcode above to specify the time interval before the scan engine times out.
2) Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. For example, read “1”
and “5” for the scanner to automatically shut down after being idle for 15 seconds.
3) Read the “Validate” barcode on the same page to complete this setting.
41
Update
1660 Barcode Scanner User Guide
1.8 DELAY BETWEEN RE-READ
This is also referred to as the “Blocking Time”, which is used to prevent the scanner from
accidentally reading the same barcode twice when the scan mode is set to any of the
following –
 Continuous mode
 Auto Power Off mode
 Alternate mode
100 ms
200 ms
*400 ms
800 ms
1 sec
2 sec
3 sec
5 sec
42
Enter Setup
Chapter 1
1.9 READ REDUNDANCY FOR ALL SYMBLOGIES
Select the level of reading security. For example,
 If "No Redundancy" is selected, one successful decoding will make the reading valid
and induce the "READER Event".
 If "Three Times" is selected, it will take a total of four consecutive successful
decoding of the same barcode to make the reading valid. The higher the reading
security is (that is, the more redundancy the user selects), the slower the reading
speed gets.
It is obvious that the more redundancy you select, the higher the reading security is, and
thus, the slower the reading speed becomes. You will have to compromise between
reading security and decoding speed.
*No Redundancy
One Time
Two Times
Three Times
43
Update
1660 Barcode Scanner User Guide
1.10 ADDON SECURITY FOR UPC/EAN BARCODES
The scanner is capable of decoding a mix of UPC/EAN barcodes with and without addons.
The read redundancy (0~30 times) allows changing the number of times to decode a
UPC/EAN barcode before transmission. The more redundancy you select, the higher the
reading security is, and thus, the slower the reading speed becomes. You will have to
compromise between reading security and decoding speed.
Note: UPC/EAN Addon 2 and Addon 5 must be enabled individually for this setting to
take effect.
Addon Security Level
(*0~30)
1) Read the barcode above to specify the read redundancy for UPC/EAN barcodes. (It is
set to 0 by default.)
2) Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. For example, read “1”
and “2” for the scanner to re-read the barcode for 12 times.
3) Read the “Validate” barcode on the same page to complete this setting.
44
Enter Setup
Chapter 1
1.11 NEGATIVE BARCODES
Normally, barcodes are printed with the color of the bars darker than that of the spaces.
But for negative barcodes, they are printed in the opposite sense just like negative films.
The spaces of negative barcodes are printed with a color darker than that of the bars.
You can configure the scanner to be able to read negative barcodes.
Enable
*Disable
45
Update
1660 Barcode Scanner User Guide
1.12 EFFECTIVE DECODING AREA
By default, the effective decoding area is 100% covered by the scanned area. However,
you may narrow down the decoding area to prevent reading the wrong barcode when a
number of barcodes are printed closely. The scanner will only read barcodes that appear
in the effective decoding area.
Read the barcode “Centering On” and specify the percentage to narrow down the
decoding area. For example, read “Left 10%” and then “Right 30%” for the scanner to
decode barcode “A” only.
1.12.1 POSITIONING WINDOW
Centering On
*Centering Off
46
Enter Setup
Chapter 1
1.12.2 ADJUSTING WINDOW
Percentage for Left Half
*Left 50%
Left 40%
Left 30%
Left 20%
Left 10%
Percentage for Right Half
Right 10%
Right 20%
Right 30%
Right 40%
*Right 50%
47
Update
1660 Barcode Scanner User Guide
48
Enter Setup
Chapter 2
SELECTING OUTPUT INTERFACE
In order to establish a proper connection between your computer and the scanner, we
suggest that you follow these instructions –
1) Install batteries and hold down the [Power/Delete] key for about 2 seconds to turn on
the scanner.
2) Have the scanner read the “Enter Setup” barcode to enter the configuration mode.
3) Have the scanner read the associated barcodes to activate the desired interface.
See the following sections for output interfaces supported.
4) Have the scanner read the barcodes for related settings.
5) Have the scanner read the “Update” barcode to exit the configuration mode.
6) Turn on your computer or laptop and establish a WPAN connection with the scanner.
Refer to Chapter 3 – Setting up a WPAN Connection.
Note: By default, the output interface is set to “BT HID”.
IN THIS CHAPTER
2.1
2.2
2.3
2.4
2.5
BT HID ...................................................................... 50
BT SPP Slave .............................................................. 61
BT SPP Master ............................................................ 63
USB HID via 3610 ....................................................... 67
USB Virtual COM via 3610 ............................................ 76
49
Update
1660 Barcode Scanner User Guide
2.1 BT HID
For BT HID, refer to Chapter 3 – Setting up a WPAN Connection for related connection
settings. Run any text editor on your computer, and the scanned data will be transmitted
to the computer.
HID Settings
Defaults
Keyboard Type
PCAT (US)
Alphabets Layout
Normal
Digits Layout
Normal
Capital Lock Type
Normal
Capital Lock State
Off
Alphabets Transmission
Case-sensitive
Digits Transmission
Alphanumeric keypad
Inter-Function Delay
0 (ms)
2.1.1 ACTIVATE BT HID & SELECT KEYBOARD TYPE
When BT HID interface is activated, you will have to select a keyboard type to complete
this setting. By default, BT HID is activated on the scanner, and the keyboard type is set
to PCAT (US).
Activate BT HID &
Select Keyboard
Type…
1) Read the barcode above to activate BT HID and select a keyboard type.
Note: If the scanner responds with one long beep (low tone) upon reading the barcode,
it means the current firmware of your scanner is earlier than version 1.21. Please
upgrade the firmware to version 1.21 or later!
2) Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. Refer to the table
below for the number of desired keyboard type.
3) Read the “Validate” barcode on the same page to complete this setting.
50
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
BT HID
By default, the keyboard type is set to PCAT (US). The following keyboard types are supported —
No.
Keyboard Type
No.
Keyboard Type
64
PCAT (US)
71
PCAT (Belgium)
65
PCAT (French)
72
PCAT (Spanish)
66
PCAT (German)
73
PCAT (Portuguese)
67
PCAT (Italy)
74
PS55 A01-2 (Japanese)
68
PCAT (Swedish)
75
User-defined table
69
PCAT (Norwegian)
76
PCAT (Turkish)
70
PCAT (UK)
2.1.2 RESET CONNECTION
For BT HID, you can only have the scanner connected to one computer at a time. If you
want to connect the scanner to another host, you must have it read the “Reset
Connection” barcode so that the current connection record will be cleared. Then, the
scanner will restart itself automatically. Go through the whole process in 3.2.3 Connect to
Dongle to establish a new connection.
Reset Connection
Note: The “Restore System Defaults” barcode will have the current connection record
cleared as well.
51
Update
1660 Barcode Scanner User Guide
2.1.3 KEYBOARD SETTINGS






Alphabets Layout
Digits Layout
Capital Lock Type
Capital Lock Setting
Alphabets Transmission
Digits Transmission
Note: BT HID does not support these functions on PDAs – (1) Capital Lock Setting: Auto
Detection (2) Digits Transmission: Numeric Key
Alphabets Layout
By default, the alphabets layout is set to normal mode, also known as the standard English layout.
Select French or German keyboard layout if necessary. The scanner will make adjustments when
sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting.
*Normal
AZERTY
QWERTZ
Note: This setting only works when the keyboard type selected is US keyboard, such as
PCAT (US). The Alphabets Layout and Digits Layout setting must match your
keyboard.
52
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
US Keyboard Style – Normal
QWERTY layout, which is normally used in western countries.

Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.
French Keyboard Style – AZERTY
French layout; see below for French Keyboard Style.

Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters.
German Keyboard Layout – QWERTZ
German layout; see below for German Keyboard Style.

Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.
53
Update
1660 Barcode Scanner User Guide
Digits Layout
Select a proper layout that matches the alphabets layout. The scanner will make adjustments
according to this setting.
Options
Description
Normal
Depends on the [Shift] key or [Shift Lock] setting
Lower Row
For QWERTY or QWERTZ keyboard
Upper Row
For AZERTY keyboard
*Normal
Upper Row
Lower Row
Note: This setting is to be used with the Character Substitution setting when support to
certain keyboard types (languages) is unavailable but required.
54
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
Capital Lock Type & Setting
In order to send the alphabets with correct case, the scanner needs to know the status of Caps
Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being
transmitted.
Cap Lock Type
Description
Normal
Normal type
Capital Lock
When enabled, the keys of alphabetic characters will be interpreted as
capital letters. However, this does not affect the number or punctuation
keys.
Shift Lock
When enabled, the keys of alphabetic characters will be interpreted as
capital letters. In addition, this affects the number or punctuation keys.
*Normal
Shift Lock
Capital Lock
Capital Lock State
Description
Capital Lock OFF
Assuming that the status of Caps Lock on the keyboard is OFF,
transmitted characters are exactly the same as in the barcode (when
"case-sensitive" is selected for Alphabets Transmission).
Capital Lock ON
Assuming that the status of Caps Lock on the keyboard is ON, transmitted
characters are exactly the same as in the barcode (when "case-sensitive"
is selected for Alphabets Transmission).

Auto Detection
Refer to the Capital Lock Type above.
The scanner will automatically detect the status of Caps Lock on the
keyboard before data is transmitted; transmitted characters are exactly
the same as in the barcode (when "case-sensitive" is selected for
Alphabets Transmission).

This setting is not supported on PDAs.
Auto Detect
Capital Lock ON
55
Update
1660 Barcode Scanner User Guide
*Capital Lock OFF
56
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
Alphabets Transmission
By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be
transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the
Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of
Caps Lock on the keyboard only.
Ignore Case
*Case-sensitive
Refer to 5.1 Letter Case.
57
Update
1660 Barcode Scanner User Guide
Digits Transmission
By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you
wish to use the keys on the numeric keypad.
Numeric Key
*Alphanumeric Key
Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard
should be “ON”. This setting is not supported on PDAs.
58
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
2.1.4 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254,
to match the computer response time of the keyboard interface. Such delay time is
inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the
delay time is, the slower the transmission speed will be.
Value
Delay Time
Value
Delay Time
Disable
195 ~ 204
200 millisecond
1 ~ 14
10 millisecond
205 ~ 214
210 millisecond
15 ~ 24
20 millisecond
215 ~ 224
220 millisecond
25 ~ 34
30 millisecond
225 ~ 234
230 millisecond
35 ~ 44
40 millisecond
235 ~ 244
240 millisecond
45 ~ 54
50 millisecond
245 ~ 254
250 millisecond
…
…
Inter-Function
Delay… (*0~254)
1) Read the barcode to specify the inter-function delay.
2) Read the “Decimal Value” barcode on page 錯 誤 ! 尚 未 定 義 書 籤 。 for the desired
inter-function delay (millisecond).
3) Read the “Validate” barcode on the same page to complete this setting.
2.1.5 HID CHARACTER TRANSMIT MODE
By default, HID interface sends data to the host in batch. You may have the scanner read
the “By Character” barcode to process data one character at a time.
*Batch Processing
By Character
Note: “By Character” transmit mode is required when working with iPhone or iPad.
59
Update
1660 Barcode Scanner User Guide
2.1.6 KEYPAD SUPPORT FOR IPHONE/IPAD
When the scanner has been successfully connected to iPhone or iPad for data collection,
the onscreen keypad of iPhone or iPad will disappear. You may have the scanner read the
“Use POWER Key to Show or Hide Keypad” barcode in advance. Then, it will allow
pressing the [Power/Delete] key to show or hide the onscreen keypad.
Note: This function only works for
(1) iPhone 4 and 3GS version 4.1 or later, and (2) iPad version 4.2 or later.
*Normal
Use POWER Key to
Show or Hide Keypad
Instead of using the [Power/Delete] key, you may have the scanner read the following
barcode to show or hide the keypad.
Show or Hide Keypad
60
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
2.2 BT SPP SLAVE
For BT SPP Slave, refer to Chapter 3 – Setting up a WPAN Connection for related
connection settings.
2.2.1 ACTIVATE BT SPP SLAVE MODE
This is SPP Slave Mode.
Activate BT SPP,
Slave Mode
2.2.2 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254,
to match the computer response time of the keyboard interface. Such delay time is
inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the
delay time is, the slower the transmission speed will be.
Value
Delay Time
Value
Delay Time
Disable
195 ~ 204
200 millisecond
1 ~ 14
10 millisecond
205 ~ 214
210 millisecond
15 ~ 24
20 millisecond
215 ~ 224
220 millisecond
25 ~ 34
30 millisecond
225 ~ 234
230 millisecond
35 ~ 44
40 millisecond
235 ~ 244
240 millisecond
45 ~ 54
50 millisecond
245 ~ 254
250 millisecond
…
…
Inter-Function
Delay… (*0~254)
1) Read the barcode above to specify the inter-function delay.
2) Read the “Decimal Value” barcode on page 錯 誤 ! 尚 未 定 義 書 籤 。 for the desired
inter-function delay (millisecond).
3) Read the “Validate” barcode on the same page to complete this setting.
61
Update
1660 Barcode Scanner User Guide
2.2.3 ACK/NAK TIMEOUT
By default, the scanner sends data to the host without waiting for an ACK/NAK response
before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If
no response within the specified period of time, the scanner will attempt to send the
same data two more times. If all three attempts fail without any notification, data loss
will occur.
ACK/NAK Time-out
after … (*0~99)
1) Read the barcode to specify the time interval for the scanner to send data and wait
for a response from the host.
2) Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. For example, read “1”
and “0” for the scanner to automatically shut down after being idle for 1 second.
3) Read the “Validate” barcode on the same page to complete this setting.
ACK/NAK Error Beep
Enable Error Beep
*Disable Error Beep
Note: We suggest enabling the error beep so that you will be notified of such data loss
and have the scanner re-read data.
62
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
2.3 BT SPP MASTER
As a SPP master device, the scanner will be able to resume connection with the host
upon powering on again, as long as the host application is running. If the scanner fails to
resume connection, it will try every 5 seconds to re-connect to the host unless you have
the scanner read the “Reset Connection” or “Restore System Defaults” barcode.
For BT SPP Master, refer to 3.2.2 Configure Related Settings for related connection
settings.
Note: In SPP Master Mode, if it fails to re-connect within the specified period of time (2
minutes by default), the scanner will become inactive to save power. Once the
re-connection is established successfully, the scanner will not go through transition
from full CPU speed to low CPU speed even though it is idle during the specified
time interval for Auto Power Off. It will automatically turn off when the time is up.
Refer to 1.1.2 Auto Power Off & Power-Saving.
2.3.1 ACTIVATE BT SPP MASTER MODE
This is SPP Master Mode.
Activate BT SPP,
Master Mode
How to connect with the target device?
Produce two setup barcodes for the target SPP slave device, just like what we do for 3610.


“Set Connection”
“MAC ID”
Note: The “MAC ID” barcode must have a prefix of two characters, either “0x” or “0X”,
followed by the real MAC address of the target device.
Usage:
1.
Read the “Activate BT SPP, Master Mode” barcode above and barcodes for connection settings,
such as authentication and preset PIN. Skip this step if no connection settings are desired.
2.
Read the “Set Connection” and “MAC ID” barcodes. The scanner will respond with one beep
upon reading each of the barcodes.
Set Connection
Prefix “0X” to target MAC address
63
Update
1660 Barcode Scanner User Guide
Note: Read the “Set Connection” barcode first, and then the “MAC ID” barcode within 10
seconds.
Instead of producing the “MAC ID” barcode, you may have the scanner read the setup barcodes for
entering the MAC address.

Have the scanner read the “Abort” barcode to cancel the operation at any time while reading
setup barcodes for the MAC address. If the MAC address has not been completed yet, having
the scanner read the “Validate” barcode can cancel the operation as well.
Enter MAC ID in
Hexadecimal…
Usage:
1.
Read the barcode above.
2.
Read the “Hexadecimal Value” barcode on page 錯誤! 尚未定義書籤。 for the desired MAC
address.
3.
Read the “Validate” barcode on the same page to complete this setting.
Exit SPP Master Mode
To stop re-connection, have the scanner read “Reset Connection” or “Restore System Defaults”
barcode so that the current connection record (= MAC ID) will be cleared. Then, the scanner will
restart itself automatically. Go through the whole process in 3.2.3 Connect to Dongle to establish a
new WPAN connection.
Reset Connection
64
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
2.3.2 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254,
to match the computer response time of the keyboard interface. Such delay time is
inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the
delay time is, the slower the transmission speed will be.
Value
Delay Time
Value
Delay Time
Disable
195 ~ 204
200 millisecond
1 ~ 14
10 millisecond
205 ~ 214
210 millisecond
15 ~ 24
20 millisecond
215 ~ 224
220 millisecond
25 ~ 34
30 millisecond
225 ~ 234
230 millisecond
35 ~ 44
40 millisecond
235 ~ 244
240 millisecond
45 ~ 54
50 millisecond
245 ~ 254
250 millisecond
…
…
Inter-Function
Delay… (*0~254)
1) Read the barcode above to specify the inter-function delay.
2) Read the “Decimal Value” barcode on page 錯 誤 ! 尚 未 定 義 書 籤 。 for the desired
inter-function delay (millisecond).
3) Read the “Validate” barcode on the same page to complete this setting.
65
Update
1660 Barcode Scanner User Guide
2.3.3 ACK/NAK TIMEOUT
By default, the scanner sends data to the host without waiting for an ACK/NAK response
before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If
no response within the specified period of time, the scanner will attempt to send the
same data two more times. If all three attempts fail without any notification, data loss
will occur.
ACK/NAK Time-out
after … (*0~99)
1) Read the barcode above to specify the time interval for the scanner to send data and
wait for a response from the host.
2) Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. For example, read “1”
and “0” for the scanner to automatically shut down after being idle for 1 second.
3) Read the “Validate” barcode on the same page to complete this setting.
ACK/NAK Error Beep
Enable Error Beep
*Disable Error Beep
Note: We suggest enabling the error beep so that you will be notified of such data loss
and have the scanner re-read data.
2.3.4 SWITCH BETWEEN MASTER/SLAVE MODE
After the scanner has established a connection as a SPP slave device, you may have it
read the “Activate BT SPP, Master Mode” setup barcode to switch to SPP Master Mode.
This will result in easy and reliable re-connection, just like connecting with 3610.
66
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
2.4 USB HID VIA 3610
For USB HID, connect 3610 to the USB port of PC, and then connect the scanner to 3610.
Run any text editor on your computer, and the scanned data will be transmitted to the
computer.
HID Settings
Defaults
Keyboard Type
PCAT (US)
Digits Layout
Normal
Capital Lock Type
Normal
Capital Lock State
Off
Alphabets Transmission
Case-sensitive
Digits Transmission
Alphanumeric keypad
Inter-Function Delay
0 (ms)
2.4.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE
When USB HID interface is activated, you will have to select a keyboard type to complete
this setting.
Activate
3610 USB HID & Select
Keyboard Type…
1) Read the barcode above to activate USB HID and select a keyboard type.
2) Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. Refer to the table
below for the number of desired keyboard type.
3) Read the “Validate” barcode on the same page to complete this setting.
USB HID
By default, the keyboard type is set to PCAT (US). The following keyboard types are supported —
No.
Keyboard Type
No.
Keyboard Type
64
PCAT (US)
71
PCAT (Belgium)
65
PCAT (French)
72
PCAT (Spanish)
66
PCAT (German)
73
PCAT (Portuguese)
67
PCAT (Italy)
74
PS55 A01-2 (Japanese)
68
PCAT (Swedish)
75
User-defined table
69
PCAT (Norwegian)
76
PCAT (Turkish)
70
PCAT (UK)
67
Update
1660 Barcode Scanner User Guide
2.4.2 KEYBOARD SETTINGS






Alphabets Layout
Digits Layout
Capital Lock Type
Capital Lock Setting
Alphabets Transmission
Digits Transmission
Alphabets Layout
By default, the alphabets layout is set to normal mode, also known as the standard English layout.
Select French or German keyboard layout if necessary. The scanner will make adjustments when
sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting.
*Normal
AZERTY
QWERTZ
Note: This setting only works when the keyboard type selected is US keyboard, such as
PCAT (US). The Alphabets Layout and Digits Layout setting must match your
keyboard.
68
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
US Keyboard Style – Normal
QWERTY layout, which is normally used in western countries.

Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.
French Keyboard Style – AZERTY
French layout; see below for French Keyboard Style.

Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters.
German Keyboard Layout – QWERTZ
German layout; see below for German Keyboard Style.

Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters.
69
Update
1660 Barcode Scanner User Guide
Digits Layout
Select a proper layout that matches the alphabets layout. The scanner will make adjustments
according to this setting.
Options
Description
Normal
Depends on the [Shift] key or [Shift Lock] setting
Lower Row
For QWERTY or QWERTZ keyboard
Upper Row
For AZERTY keyboard
*Normal
Upper Row
Lower Row
Note: This setting is to be used with the Character Substitution setting when support to
certain keyboard types (languages) is unavailable but required.
70
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
Capital Lock Type & Setting
In order to send the alphabets with correct case, the scanner needs to know the status of Caps
Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being
transmitted.
Cap Lock Type
Description
Normal
Normal type
Capital Lock
When enabled, the keys of alphabetic characters will be interpreted as
capital letters. However, this does not affect the number or punctuation
keys.
Shift Lock
When enabled, the keys of alphabetic characters will be interpreted as
capital letters. In addition, this affects the number or punctuation keys.
*Normal
Shift Lock
Capital Lock
Capital Lock State
Description
Capital Lock OFF
Assuming that the status of Caps Lock on the keyboard is OFF,
transmitted characters are exactly the same as in the barcode (when
"case-sensitive" is selected for Alphabets Transmission).
Capital Lock ON
Assuming that the status of Caps Lock on the keyboard is ON, transmitted
characters are exactly the same as in the barcode (when "case-sensitive"
is selected for Alphabets Transmission).

Auto Detection
Refer to the Capital Lock Type above.
The scanner will automatically detect the status of Caps Lock on the
keyboard before data is transmitted; transmitted characters are exactly
the same as in the barcode (when "case-sensitive" is selected for
Alphabets Transmission).
Auto Detect
Capital Lock ON
71
Update
1660 Barcode Scanner User Guide
*Capital Lock OFF
72
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
Alphabets Transmission
By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be
transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the
Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of
Caps Lock on the keyboard only.
Ignore Case
*Case-sensitive
Refer to 5.1 Letter Case.
73
Update
1660 Barcode Scanner User Guide
Digits Transmission
By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you
wish to use the keys on the numeric keypad.
Numeric Key
*Alphanumeric Key
Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard
should be "ON".
74
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
2.4.3 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254,
to match the computer response time of the keyboard interface. Such delay time is
inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the
delay time is, the slower the transmission speed will be.
Value
Delay Time
Value
Delay Time
Disable
195 ~ 204
200 millisecond
1 ~ 14
10 millisecond
205 ~ 214
210 millisecond
15 ~ 24
20 millisecond
215 ~ 224
220 millisecond
25 ~ 34
30 millisecond
225 ~ 234
230 millisecond
35 ~ 44
40 millisecond
235 ~ 244
240 millisecond
45 ~ 54
50 millisecond
245 ~ 254
250 millisecond
…
…
Inter-Function
Delay… (*0~254)
1) Read the barcode above to specify the inter-function delay.
2) Read the “Decimal Value” barcode on page 錯 誤 ! 尚 未 定 義 書 籤 。 for the desired
inter-function delay (millisecond).
3) Read the “Validate” barcode on the same page to complete this setting.
2.4.4 HID CHARACTER TRANSMIT MODE
By default, HID interface sends data to the host in batch. You may have the scanner read
the “By Character” barcode to process data one character at a time.
*Batch Processing
By Character
75
Update
1660 Barcode Scanner User Guide
2.5 USB VIRTUAL COM VIA 3610
Connect 3610 to the USB port of PC, and then connect the scanner to 3610. You may run
HyperTerminal.exe on your computer, and the scanned data will be transmitted to the
computer.
Note: If you are using USB Virtual COM for the first time, you must install its driver from
the CD-ROM. Driver version 5.3 or later is required. Please remove older versions!
2.5.1 ACTIVATE USB VIRTUAL COM
Activate 3610 USB
Virtual COM
2.5.2 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254,
to match the computer response time of the keyboard interface. Such delay time is
inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the
delay time is, the slower the transmission speed will be.
Value
Delay Time
Value
Delay Time
Disable
195 ~ 204
200 millisecond
1 ~ 14
10 millisecond
205 ~ 214
210 millisecond
15 ~ 24
20 millisecond
215 ~ 224
220 millisecond
25 ~ 34
30 millisecond
225 ~ 234
230 millisecond
35 ~ 44
40 millisecond
235 ~ 244
240 millisecond
45 ~ 54
50 millisecond
245 ~ 254
250 millisecond
…
…
Inter-Function
Delay… (*0~254)
1) Read the barcode above to specify the inter-function delay.
2) Read the “Decimal Value” barcode on page 錯 誤 ! 尚 未 定 義 書 籤 。 for the desired
inter-function delay (millisecond).
3) Read the “Validate” barcode on the same page to complete this setting.
76
Enter Setup
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
2.5.3 ACK/NAK TIMEOUT
By default, the scanner sends data to the host without waiting for an ACK/NAK response
before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If
no response within the specified period of time, the scanner will attempt to send the
same data two more times. If all three attempts fail without any notification, data loss
will occur.
ACK/NAK Time-out
after … (*0~99)
1) Read the barcode above to specify the time interval for the scanner to send data and
wait for a response from the host.
2) Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。. For example, read “1”
and “0” for the scanner to automatically shut down after being idle for 1 second.
3) Read the “Validate” barcode on the same page to complete this setting.
ACK/NAK Error Beep
Enable Error Beep
*Disable Error Beep
Note: We suggest enabling the error beep so that you will be notified of such data loss
and have the scanner re-read data.
77
Update
1660 Barcode Scanner User Guide
78
Enter Setup
Chapter 3
SETTING UP A WPAN CONNECTION
The scanner can be configured to send data to a host computer wirelessly via the 3610
dongle, or to a notebook computer or PDA with Bluetooth® wireless technology. Upon
powering up, the scanner will be ready for establishing a WPAN connection.
To establish a connection via 3610 after reading “Set Connection” and “Serial No.” labels …
Interface Option
Reference
USB HID
2.4 USB HID via 3610
USB Virtual COM
2.5 USB Virtual COM via 3610
To establish a connection via Bluetooth® dongle after pairing …
Interface Option
Reference
BT HID
2.1 BT HID
BT SPP
2.2 BT SPP Slave, 2.3 BT SPP Master
IN THIS CHAPTER
3.1 Connecting via 3610 .................................................... 80
3.2 Connecting via Bluetooth® Dongle ................................. 83
79
Update
1660 Barcode Scanner User Guide
3.1 CONNECTING VIA 3610
By default, the interface of 3610 is set to “USB HID”. Connect 3610 to the USB port of PC,
and then connect the scanner to 3610. You can have up to seven scanners connected to
one computer at the same time.
Note: If you are using USB Virtual COM for the first time, you must install its driver from
the CD-ROM. Driver version 5.3 or later is required. Please remove older versions!
3.1.1 CONNECT TO 3610
You can connect any scanner to 3610 by having the scanner read the two labels at the
back of 3610. The scanner will respond with one beep upon reading each of the labels.
 “Set Connection” label
 “Serial Number” label
After reading these labels, the scanner will stay active for a specified period of time (2
minutes by default) trying to connect to the 3610 dongle while its LED is flashing blue
(On/Off ratio 0.5 s: 0.5 s). Once connected, the scanner will respond with three beeps
(tone ascending from low to high), and the LED becomes flashing blue (On/Off ratio 0.02
s: 3 s). When getting out of range, the scanner will respond with three short beeps (tone
descending from high to low).
Read the “Set Connection” label first, and then the “Serial Number” label. If the “Set
Connection” label on 3610 is illegible, try this one —
Set Connection
Note: The 3610 settings will overwrite the interface-related settings on the scanners that
are currently connected to 3610.
80
End Programming Format
Chapter 3
3.1.2 CHANGE INTERFACE
If you want to change the interface 3610, use one of the connected scanners to configure
the interface-related settings and it will pass the new settings to 3610, which will then
initialize and pass the settings to any other connected scanners.
1) Have the scanners read the “Set Connection” and “Serial Number” labels at the back
of 3610.
2) Within two minutes, connect 3610 to the USB port of PC. For USB Virtual COM, you
may need to install its driver first!
3) The scanners will connect to your computer via 3610.
4) Have one scanner read the “Enter Setup” barcode to enter the configuration mode.
5) Have the scanner read the desired interface barcode and configure its related
settings –
 “Activate USB HID & Select Keyboard Type”
 “Activate USB Virtual COM”
6) Have the scanner read the “Update” barcode to exit the configuration mode.
7) After the scanner resumes connection with 3610, it will pass the interface-related
settings to 3610.
8) Upon receipt of the new settings, 3610 will initialize itself.
9) Updated with new settings, 3610 will pass the settings to other connected scanners.
81
Update
1660 Barcode Scanner User Guide
3.1.3 CONFIGURE RELATED SETTINGS
Sniff Mode (Power-saving)
By default, this feature is enabled, meaning the scanner will listen to the wireless network at a
reduced rate.
*Enable
Disable
82
End Programming Format
Chapter 3
3.2 CONNECTING VIA BLUETOOTH® DONGLE
3.2.1 CHANGE INTERFACE
Below is the procedure to configure the scanner before establishing a WPAN connection
via Bluetooth® dongle.
1) Have the scanner read the “Enter Setup” barcode to enter the configuration mode.
2) Have the scanner read the desired interface barcode –
 “Activate BT HID & Select Keyboard Type”
 “Activate BT SPP Slave Mode”
 “Activate BT SPP Master Mode”
3) Have the scanner read the barcodes related to WPAN settings, such as Device Name
Broadcasting, Authentication & PIN Code, etc.
4) Have the scanner read the “Update” barcode to exit the configuration mode.
5) The scanner will stay active for a specified period of time (2 minutes by default)
waiting for a connection request from the host (SPP Slave Mode) or trying to connect
to the host (HID or SPP Master Mode). Its CPU is running at full speed, and the LED is
flashing blue (On/Off ratio 0.5 s: 0.5 s).
Once connected, when getting out of range, the scanner will respond with three short
beeps (tone descending from high to low).
83
Update
1660 Barcode Scanner User Guide
3.2.2 CONFIGURE RELATED SETTINGS
Sniff Mode (Power-saving)
By default, this feature is enabled, meaning the scanner will listen to the wireless network at a
reduced rate.
*Enable
Disable
Note: When connecting more than two scanners to a notebook computer or PDA with
Bluetooth® wireless technology, we suggest that you disable the power-saving
setting for a more reliable connection.
Device Name Broadcasting
The scanner can be configured to hide itself from other devices equipped with Bluetooth® wireless
technology. Simply disable the device name broadcasting setting so that it won’t be discovered by
any other computer or PDA. However, broadcasting must be enabled for establishing an initial
connection with the scanner. For example, you can disable device name broadcasting after
successfully connecting the scanner to WorkStation1. Such connection will be maintained
automatically unless the scanner is removed from the paired device list (called unpairing) by
WorkStation1 or any changes made to authentication and the PIN code. If you want WorkStation2
to connect to the scanner, you will have to enable device name broadcasting first.
*Enable
Disable
Note: By default, device name broadcasting is enabled (which is required for initial
connection).
84
End Programming Format
Chapter 3
Authentication
When any changes are made to authentication and PIN code on the scanner side, you will have to
remove the scanner from the paired device list (called unpairing) and go through the whole process
to re-establish the connection.
The scanner allows up to 16 characters for a PIN code and provides two options for authentication:
Enable Authentication with Preset PIN
Have the scanner read the “Use preset PIN” barcode, and change the preset PIN if necessary.
This means you will have to enter exactly the same string for your computer or PDA to connect
to the scanner. If the PIN or passkey is incorrect, any connection attempt will be turned down by
the scanner. See step 8 in 3.2.3 Connect to Dongle.
1.
Read the “Use preset PIN” barcode to enable authentication with a preset PIN.
Use Preset PIN
2.
Read one of the barcodes to specify the PIN code, in decimal or hexadecimal.
By default, the PIN code is set to “0000”. Maximum 16 characters are allowed.
Enter PIN in
Hexadecimal …
Enter PIN in
Decimal…
3.
Read the “Decimal Value” barcode on page 錯誤! 尚未定義書籤。 or the “Hexadecimal Value”
barcode on page 錯誤! 尚未定義書籤。 for the desired digits or character string.
Read the “Clear PIN Code” barcode first if you need to re-input the PIN code.
Clear PIN Code
4.
Read the “Validate” barcode to complete this setting.
Enable Authentication with Random PIN or No Authentication
By default, it is set to “No PIN or use random PIN”, which depends on the setting of the target
device. (No PIN = No authentication.)
*No PIN or
use random PIN
85
Update
1660 Barcode Scanner User Guide
Use random PIN
No PIN required
Note: When using BT HID, some device driver may not support pre-defined PIN code for
authentication. In this case, make sure you have the scanner set to “No PIN or use
random PIN” before pairing. While pairing, the host PIN code will be displayed on
the computer screen. Have the scanner read the setup barcode “Enter PIN Code in
Decimal” or “Enter PIN Code in Hexadecimal” to input the matching PIN code.
Refer to Disable Authentication or Use Random PIN.
86
End Programming Format
Chapter 3
3.2.3 CONNECT TO DONGLE
The procedure goes through associating devices for establishing a WPAN connection,
which is pretty much the same except for the software you are using. If your computer is
running Microsoft® Windows® XP Service Pack 3 (SP3) or Windows Vista® Service Pack 1
(SP1), you can use the software support that Windows® includes, or you can use the
driver that the device manufacturer provides. Now, let’s try using the software support
that Windows® XP Service Pack 2 includes.
BT HID Procedure
By default, BT HID is activated on the scanner, and the keyboard type is set to PCAT (US). When
BT HID is re-activated, you will have to select a keyboard type to complete this setting.
The procedure is the same as for BT SPP. Refer to steps 1~11 below.
BT SPP Slave Procedure
1.
2.
Turn on the Bluetooth® function on your computer, running Windows XP SP2.
Double-click the Bluetooth® icon from the lower right of the taskbar.
Alternatively, you may go to Control Panel > Bluetooth Devices.
3.
Click [Add] to search devices nearby.
87
Update
1660 Barcode Scanner User Guide
4.
Turn on the scanner with correct WPAN settings, such as select BT SPP or BT HID,
broadcasting enabled, authentication enabled, and PIN code specified, etc. Select the check
box of [My device is set up and ready to be found] on your computer.
5.
Click [Next].
6.
Wait for a few seconds for the Wizard to search available devices nearby.
The scanner will appear with its “serial number” as the device name. You may double-check
the “Serial Number” label on the scanner to ensure connecting with the correct scanner.
Select the target scanner. If the target scanner does not appear on the list, click [Search
Again] to refresh the list. The scanner might enter Suspend Mode now, and you can press the
trigger to have it active again (=discoverable). It will then stay active for a specified period of
time (2 minutes by default) and wait for PC to establish a connection.
7.
Click [Next].
88
End Programming Format
Chapter 3
8.
Enter the passkey for authentication, which must be exactly the same as configured for the
scanner.
9.
Click [Next]. Wait for a few seconds for Windows to exchange passkeys.
89
Update
1660 Barcode Scanner User Guide
90
End Programming Format
Chapter 3
Note: When Bluetooth security is enabled without providing a pre-set PIN code, dynamic
input of PIN code is supported.
10.
Click [Finish].
1660/1661 as BT SPP Slave
1660/1661 as BT SPP Master
91
Update
1660 Barcode Scanner User Guide
11.
Now the target scanner will be listed as shown below.
You can have up to seven scanners connected to one computer at the same time.
Select and Remove
Note: When any changes are made to authentication and PIN code on the scanner side,
or you want to change to use BT HID, it is suggested that you remove the scanner
from the paired device list (called unpairing) and go through the whole process to
re-establish the connection.
12.
Run the desired application on your computer, such as HyperTerminal.exe if using BT SPP or
Notepad.exe if using BT HID.
The status of the scanner listed on the device list will be updated to “Connected”, indicating
the WPAN connection is established successfully via the outgoing COM port if using BT SPP.
Note: Even though the scanner is connected to the host with authentication disabled (=
no PIN code required), the host may still request a PIN code while the application
is opening COM port. Dynamic input of PIN code is supported so that you may
input a matching PIN code on the scanner. Refer to Disable Authentication or Use
Random PIN.
92
End Programming Format
Chapter 3
BT SPP Connected
BT SPP Disconnected
93
Update
1660 Barcode Scanner User Guide
94
End Programming Format
SPECIFICATIONS
Optical Characteristics
1660
Scan Engine
Non-contact type
Optical Sensor
CCD, 2500 pixels
Light Source
Visible red LED
1661
RF Characteristics
WPAN Module
Wireless PAN BT Class 3 compliance
Coverage (line-of-sight)
10 meters with 3610
Interface Supported



Serial Port Profile (BT SPP)


1 KB for transmit buffer
Human Interface Device Profile (BT HID)
3610
Physical Characteristics
Memory
256 KB flash for memory mode
Switch
Push-button switch for [Trigger] key, plus [Power/Delete] key
Indication
Triple-color LED (Red/Green/Blue) and beeper
Dimensions
95 mm (L) 35 mm (W) 20 mm (H)
Weight
Approx. 50 g
95
Update
1660 Barcode Scanner User Guide
Electrical Characteristics
Battery
2 AAA Alkaline batteries
Rechargeable Li-ion battery —
3.7 V, 850 mAh
Input
---
AC 100~240 V (50/60 Hz)
Output
---
DC 5V ± 5%
Power Adapter
(via battery charger)
Environmental Characteristics
Temperature
Humidity
(Non-condensing)
Operating
0 °C to 50 °C
Storage
-20 °C to 60 °C
Operating
10% to 90%
Storage
5% to 95%
Resistance
Electrostatic Discharge
± 15 kV air discharge, ± 8 kV contact discharge
Programming Support
Configuration via Setup Barcodes Use setup barcodes or host serial commands.
Software
Windows®-based ScanMaster
Firmware upgradeable
Download firmware updates via the download utility.
Accessories (√ means “supported”)
BT Transponder (3610)
√
√
Rechargeable Li-ion Battery
√
Direct USB Cable
√
96
Enter Setup
Update
Abort
97

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Carrie Chen
Comments                        : Copyright © CipherLab Co., Ltd., all rights reserved.
Company                         : CipherLab Co., Ltd.
Create Date                     : 2010:12:03 17:01:41+08:00
Modify Date                     : 2010:12:03 17:02:00+08:00
Source Modified                 : D:20101203090107
Subject                         : User Guide
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2010:12:03 17:02+08:00
Creator Tool                    : Acrobat PDFMaker 9.1 Word 版
Document ID                     : uuid:1aed2d60-999f-410e-9950-d69feab80f2a
Instance ID                     : uuid:aae7156d-6b27-43d9-ab0e-2ba2e0c59d7f
Format                          : application/pdf
Title                           : 1660 Barcode Scanner
Description                     : User Guide
Creator                         : Carrie Chen
Producer                        : Adobe PDF Library 9.0
Keywords                        : 
Headline                        : User Guide
Page Layout                     : OneColumn
Page Count                      : 105
EXIF Metadata provided by EXIF.tools