CipherLab 36662 Cradle User Manual Scanner Configuration

CipherLab Co., Ltd. Cradle Scanner Configuration

User manual

DOCVersion2.21Thisdocumentisspecificallydesignedfortheusertoprinttwopagespersheetofpaperwithoptimalprintquality.
Copyright © 2005~ 2008 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a license agreement containing restrictions on use and disclosure and is also protected by copyright law.    Reverse engineering of the software is prohibited. Due to continued product development this information may change without notice.    The information and intellectual property contained herein is confidential between CIPHERLAB and the client and remains the exclusive property of CIPHERLAB CO., LTD.    If you find any problems in the documentation, please report them to us in writing.    CIPHERLAB does not warrant that this document is error-free. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of CIPHERLAB CO., LTD. For product consultancy and technical support, please contact your local sales representative. Also, you may visit our web site for more information. The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD.   Microsoft, Windows, and the Windows logo are registered trademarks of Microsoft Corporation in the United States and/or other countries.   Bluetooth is a trademark of Bluetooth SIG, Inc., U.S.A. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.   The editorial use of these names is for identification as well as to the benefit of the owners, with no intention of infringement. CIPHERLAB CO., LTD.Website: http://www.cipherlab.com
VERSION  DATE  NOTES2.21  Jan. 02, 2008  Larger setup barcodes 2.20  Nov. 30, 2007  New Word template applied New: 3667 Bluetooth Cradle for 1166/1266 Modified: Auto-Sense mode supported on 1100 only. New: Appendix III – Host Serial Commands New: Appendix IV – Upgrading Firmware   2.15 Nov.13, 2006 Modified: Add notice for BT SPP and HID power saving – Please disable power saving when connecting more than two 1x66 scanners to Bluetooth dongle. 2.14~2.12Nov. 06, 2006 Mar. 03, 2006 New: Bluetooth HID supports Japanese keyboard. 2.11 Jan.27, 2006 Modified: Typo errors corrected. 2.10 Jan.18, 2006 Modified: Bluetooth HID doesn’t support the following functions on PDAs running Windows CE – Capital Lock Setting: Auto Detection, Digit Transmission: Numeric Key, and Alt Composing. Modified: The default Capital Lock setting of Bluetooth HID is changed from “Auto Detection” to “Capital Lock Off”. New: Firmware version V4.20 2.00  Dec. 30, 2005  New: Bluetooth HID supported New: Firmware version V4.10 1.00  Oct. 31, 2005  First release RELEASE NOTES
CONTENTSRELEASE NOTES.................................................................................................................................. 3OVERVIEW............................................................................................................................................ 1Enter Configuration Mode................................................................................................................. 1Exit Configuration Mode.................................................................................................................... 1Update Settings............................................................................................................................ 1Exit without Changes.................................................................................................................... 1Restore Defaults................................................................................................................................ 1List Current Settings.......................................................................................................................... 2BLUETOOTH SETTINGS (1166/1266)................................................................................................. 31.1 RF Auto Shutdown (Suspend mode) ......................................................................................... 31.2 Power Saving (Sniff Mode)......................................................................................................... 31.3 Transmit Buffer Setting .............................................................................................................. 31.4 Memory Mode............................................................................................................................. 31.4.1 Memory Mode .................................................................................................................... 31.4.2 Send Data........................................................................................................................... 41.4.3 Clear Data........................................................................................................................... 41.4.4 Memory Data Delay............................................................................................................ 41.5 Set Connection with 3666 ......................................................................................................... 51.6 Set Connection with 3667 or Generic Dongle .......................................................................... 51.6.1 Bluetooth Serial Port Parameters ..................................................................................... 51.6.2 Bluetooth HID Parameters................................................................................................. 6READER SETTINGS .............................................................................................................................. 92.1 Good Read Notification .............................................................................................................. 92.1.1 Buzzer Setting .................................................................................................................... 92.1.2 Buzzer Frequency............................................................................................................... 92.2 Read Redundancy ...................................................................................................................... 92.3 Scan Mode .................................................................................................................................. 92.4 Auto-Sense Mode (1100 only) .................................................................................................102.5 Scanner Time-Out .....................................................................................................................102.6 Delay between Re-read ............................................................................................................102.7 Negative Barcode Setting ........................................................................................................11OUTPUT INTERFACES.........................................................................................................................133.1 Keyboard Wedge Parameters..................................................................................................133.1.1 Activate and Select Keyboard Type.................................................................................133.1.2 Alphabets Layout..............................................................................................................143.1.3 Digits Layout.....................................................................................................................143.1.4 Capital Lock Type .............................................................................................................143.1.5 Capital Lock Setting .........................................................................................................143.1.6 Alphabets Transmission ..................................................................................................15
Scanner Configuration SmartScan Manual3.1.7 Digits Transmission..........................................................................................................153.1.8 ALT Composing.................................................................................................................153.1.9 Inter-Character Delay .......................................................................................................153.1.10 Laptop Support ..............................................................................................................153.2 RS-232 Parameters..................................................................................................................163.2.1 Activate RS-232 Interface ...............................................................................................163.2.2 Baud Rate......................................................................................................................... 163.2.3 Parity .................................................................................................................................163.2.4 Data Bits ...........................................................................................................................173.2.5 Flow Control......................................................................................................................173.2.6 Inter-Character Delay .......................................................................................................173.3 WAND Emulation Parameters (1090+/1100/1105/1200) .................................................183.3.1 Activate Wand Emulation.................................................................................................183.3.2 Normal State ....................................................................................................................183.3.3 Bar State...........................................................................................................................183.3.4 Module Time.....................................................................................................................183.3.5 Margin Time......................................................................................................................19SYMBOLOGY SETTINGS.....................................................................................................................214.1 Select Readable Barcodes.......................................................................................................214.2 Codabar Parameters ................................................................................................................254.3 Code 25 Parameters ................................................................................................................264.3.1 Industrial 25 .....................................................................................................................264.3.2 Interleaved 25 .................................................................................................................. 274.3.3 Matrix 25 ..........................................................................................................................284.4 Code 39 Parameters ................................................................................................................304.5 Code 93 Parameters ................................................................................................................304.6 Code 128 Parameters..............................................................................................................304.7 EAN-8 Parameters ....................................................................................................................314.8 EAN-13 Parameters..................................................................................................................324.9 EAN-128 Parameters................................................................................................................334.10 MSI Parameters......................................................................................................................344.11 Pharmacode Parameters.......................................................................................................364.11.1 French Pharmacode ......................................................................................................364.11.2 Italian Pharmacode .......................................................................................................364.12 Plessey Parameters ...............................................................................................................374.13 RSS Family Parameters .........................................................................................................384.13.1 RSS-14............................................................................................................................384.13.2 RSS Limited....................................................................................................................384.13.3 RSS Expanded................................................................................................................394.14 Telepen Parameters...............................................................................................................404.15 UPC-A Parameters ..................................................................................................................414.16 UPC-E Parameters .................................................................................................................. 42DATA OUTPUT FORMAT......................................................................................................................435.1 Character Substitution .............................................................................................................435.2 Prefix/Suffix Setting..................................................................................................................43
Scanner Configuration SmartScan Manual5.3 Code ID Setting .........................................................................................................................435.3.1 Clear Code ID Settings.....................................................................................................435.3.2 Select Pre-defined Code ID..............................................................................................445.3.3 Change Code ID................................................................................................................445.4 Length Code Setting .................................................................................................................45DATA EDITING ....................................................................................................................................496.1 Format Selection ......................................................................................................................496.1.1 Activate Editing Formats..................................................................................................496.1.2 Exclusive Data Editing......................................................................................................496.2 Editing Format Parameters ......................................................................................................506.2.1 Select Format to Configure.............................................................................................. 506.2.2 Restore Default Format ................................................................................................... 506.2.3 Define Data Criteria ......................................................................................................... 506.2.4 Divide Data into Fields.....................................................................................................526.2.5 Additional Fields...............................................................................................................556.2.6 Field Transmission Sequence .........................................................................................56NUMERAL SYSTEMS.......................................................................................................................... 57Decimal System...............................................................................................................................57Hexadecimal System.......................................................................................................................58KEYBOARD WEDGE TABLE & ASCII TABLE........................................................................................ 59Keyboard Wedge Table ................................................................................................................... 59Key Type......................................................................................................................................59Key Status ..................................................................................................................................60ASCII Table.......................................................................................................................................60HOST SERIAL COMMANDS ................................................................................................................61Serial Commands............................................................................................................................61Example ...........................................................................................................................................61UPGRADING FIRMWARE.................................................................................................................... 63How to Upgrade 1166/1266 Firmware.........................................................................................63Using 3666................................................................................................................................. 63Using 3667 or Generic Dongle..................................................................................................64How to Upgrade 3666 Firmware ....................................................................................................65Find out Firmware Version of 3666 ..........................................................................................65
1UpdateENTER CONFIGURATION MODE Serial Command N/A Enter Setup EXIT CONFIGURATION MODE UPDATE SETTINGS Serial Command 9999 Update EXIT WITHOUT CHANGES Serial Command 9998 Abort RESTORE DEFAULTS Serial Command9993 Restore Defaults Note:  The default value (if there is) for each setting is included in a pair of angle brackets “<>”. OVERVIEW
2Enter Setup Scanner Configuration SmartScan ManualLIST CURRENT SETTINGS Serial Command 9950 List settings regarding Interface, Buzzer, and Scanner Parameters  Page 1  Serial Command 9951 List settings regarding Prefix, Postfix, and Length Code Setting  Page 2  Serial Command 9952 List settings regarding Code ID  Page 3  Serial Command 9953 List settings regarding: Readable Symbologies  Page 4  Serial Command 9954 List settings regarding Symbology Parameters (1/3) Page 5  Serial Command 9955 List settings regarding Symbology Parameters (2/3) Page 6  Serial Command 9956 List settings regarding Symbology Parameters (3/3) Page 7  Serial Command 9957 List settings regarding Editing Format 1  Page 8  Serial Command 9958 List settings regarding Editing Format 2  Page 9  Serial Command 9959 List settings regarding Editing Format 3  Page 10
3Update1.1 RF AUTO SHUTDOWN (SUSPEND MODE) 1) Read this label to specify the time interval before the scanner enters suspend mode.    2) Read the “Decimal Value” label on page 57. For example, read “1” and “5” for the scanner to suspend the connection with 3666 after being idle for 15 minutes.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0445      RF Auto Shutdownafter … minutes 1.2 POWER SAVING (SNIFF MODE) Serial Command0458Serial Command 0459       <Enable>    Disable 1.3 TRANSMIT BUFFER SETTING Serial Command0386Serial Command 0387        Enable    <Disable> 1.4 MEMORY MODE 1.4.1 MEMORY MODE Serial Command0321Serial Command 0320        Enable    <Disable> Chapter 1BLUETOOTH SETTINGS (1166/1266)
4Enter Setup Scanner Configuration SmartScan Manual1.4.2 SEND DATA Serial Command9918    Send Data 1.4.3 CLEAR DATA 1) Read the “Clear Data” label to clear the flash memory. 2) Read the “Confirm” label to confirm the action. Serial Command9916Serial Command 9917      Clear Data    Confirm 1.4.4 MEMORY DATA DELAY Serial Command0322Serial Command 0323        <None>    250 ms Serial Command0324Serial Command 0325        500 ms    1 sec Serial Command0326Serial Command 0327         2 sec    3 sec Serial Command0328Serial Command 0329         5 sec    8 sec
5UpdateChapter 1   Bluetooth Settings (1166/1266)1.5 SET CONNECTION WITH 3666 1) Read this label or the same one at the bottom of the 3666 cradle.   2) Read the “Serial Number” label at the bottom of the cradle within 5 seconds. 3) Proceed to select a desired output interface. Serial Command           Set Connection 1.6 SET CONNECTION WITH 3667 OR GENERIC DONGLE 1.6.1 BLUETOOTH SERIAL PORT PARAMETERS Serial Command0453            Activate Bluetooth SPPDEVICE NAME BROADCASTING Serial Command0450Serial Command 0451         <Yes>    No AUTHENTICATION Serial Command0448Serial Command 0449          Yes    <No> PIN CODE 1) Read this label to specify the PIN code.   2) Read the “Hexadecimal Value” label on page 58 for the desired character string (max. 6 characters are allowed).   3) Read the “Validate” label on the same page to complete this setting. Serial Command0452      Enter PIN Code …
6Enter Setup Scanner Configuration SmartScan Manual1.6.2 BLUETOOTH HID PARAMETERS 1) Read this label to activate Bluetooth HID and select a keyboard type.   2) Read the “Decimal Value” label on page 57. Refer to the table below for the number of desired keyboard type.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0000    Activate & SelectKeyboard Type … NO.  KEYBOARD TYPE  NO. KEYBOARD TYPE 64  PCAT (US)  70  PCAT (UK) 65  PCAT (French)  71  PCAT (Belgium) 66  PCAT (German)  72  PCAT (Spanish) 67  PCAT (Italian)  73  PCAT (Portuguese) 68  PCAT (Swedish)  74  PS55 A01-2 (Japanese) 69 PCAT (Norwegian)     RESET CONNECTION Read this label when switching connection from one PC to another and re-connection is required. Serial Command9972    Reset ConnectionDEVICE NAME BROADCASTING Serial Command0450Serial Command 0451         <Yes>     No AUTHENTICATION Serial Command0448Serial Command 0449          Yes     <No>
7UpdateChapter 1   Bluetooth Settings (1166/1266)PIN CODE 1) Read this label to specify the PIN code.   2) Read the “Hexadecimal Value” label on page 58 for the desired character string (max. 6 characters are allowed).   3) Read the “Validate” label on the same page to complete this setting. Serial Command0452      Enter PIN Code …ALPHABETS LAYOUT Serial Command0312Serial Command 0313   <Default Layout>     AZERTY Serial Command0314         QWERTZ      DIGITS LAYOUT Serial Command0007Serial Command 0008   <Default Layout>     Upper Row Serial Command0009       Lower Row      CAPITAL LOCK TYPE Serial Command0010Serial Command 0011       <Default>     Shift Lock Serial Command0012     Capital Lock
8Enter Setup Scanner Configuration SmartScan ManualCAPITAL LOCK SETTING Serial Command0002Serial Command 0003    Auto Detection    Capital Lock ON Serial Command0004  <Capital Lock OFF>     ALPHABETS TRANSMISSION Serial Command0005Serial Command 0006      Ignore Case    <Case-Sensitive>DIGITS TRANSMISSION Serial Command0013Serial Command 0014      Numeric Key    <Alphanumeric Key>ALT COMPOSING Serial Command0335Serial Command 0334          Yes    <No>
9Update2.1 GOOD READ NOTIFICATION 2.1.1 BUZZER SETTING Serial Command0318Serial Command 0319    <Enable Buzzer>    Disable Buzzer 2.1.2 BUZZER FREQUENCY Serial Command0046Serial Command 0047         8 kHz    <4 kHz>  Serial Command0048Serial Command 0049         2 kHz    1 kHz 2.2 READ REDUNDANCY Serial Command0201Serial Command 0202    <No Redundancy>     One Time Serial Command0203Serial Command 0204       Two Times     Three Times 2.3 SCAN MODE Serial Command0066Serial Command 0067    <Auto Off Mode>  (Default for 1000/1090+)   Continuous ModeChapter 2READER SETTINGS
10Enter Setup Scanner Configuration SmartScan ManualSerial Command0068Serial Command 0069  Auto Power Off Mode     Alternate Mode Serial Command0070Serial Command 0071    Momentary Mode    Repeat Mode Serial Command0072Serial Command 0073     <Laser Mode> (Default for 1100/1105/1166/1200/1266)   Test Mode 2.4 AUTO-SENSE MODE (1100 ONLY) Serial Command0333Serial Command 0332        Enable    <Disable> 2.5 SCANNER TIME-OUT 1) Read this label to specify the time interval before the scan engine times out in Laser, Auto Off, or Auto Power Off mode.        2) Read the “Decimal Value” label on page 57. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 10 seconds.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0207    Scanner Time-Outafter … seconds 2.6 DELAY BETWEEN RE-READ Serial Command0336Serial Command 0337        100 ms     200 ms
11UpdateChapter 2  Reader SettingsSerial Command0338Serial Command 0339       <400 ms>     800 ms Serial Command0340Serial Command 0341         1 sec     2 sec Serial Command0342Serial Command 0343         3 sec     5 sec 2.7 NEGATIVE BARCODE SETTING Serial Command0199Serial Command 0200        Enable     <Disable>
12Enter Setup Scanner Configuration SmartScan Manual
13Update3.1 KEYBOARD WEDGE PARAMETERS 3.1.1 ACTIVATE AND SELECT KEYBOARD TYPE 1) Read this label to activate Keyboard Wedge and select a keyboard type.   2) Read the “Decimal Value” label on page 57. Refer to the table below for the number of desired keyboard type.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0000    Activate & SelectKeyboard Type … NO.  KEYBOARD TYPE  NO. KEYBOARD TYPE 1  PCAT (US)  15  PS55 001-81 2  PCAT (French)  16  PS55 001-2 3  PCAT (German)  17  PS55 001-82 4  PCAT (Italian)  18  PS55 001-3 5  PCAT (Swedish)  19  PS55 001-8A 6  PCAT (Norwegian)  20  PS55 002-1, 003-1 7  PCAT (UK)  21  PS55 002-81, 003-81 8  PCAT (Belgium)  22  PS55 002-2, 003-2 9  PCAT (Spanish)  23  PS55 002-82, 003-82 10  PCAT (Portuguese)  24  PS55 002-3, 003-3 11  PS55 A01-1  25  PS55 002-8A, 003-8A 12  PS55 A01-2 (Japanese)  26  IBM 3477 Type 4 (Japanese) 13 PS55 A01-3  27 PS2-30 14  PS55 001-1  28  IBM 34XX/319X, Memorex Telex 122 Keys Chapter 3OUTPUT INTERFACES
14Enter Setup Scanner Configuration SmartScan Manual3.1.2 ALPHABETS LAYOUT Serial Command0312Serial Command 0313   <Default Layout>     AZERTY Serial Command0314         QWERTZ      3.1.3 DIGITS LAYOUT Serial Command0007Serial Command 0008   <Default Layout>     Upper Row Serial Command0009       Lower Row      3.1.4 CAPITAL LOCK TYPE Serial Command0010Serial Command 0011       <Default>     Shift Lock Serial Command0012     Capital Lock     3.1.5 CAPITAL LOCK SETTING Serial Command0002Serial Command 0003    Auto Detection    Capital Lock ON Serial Command0004  <Capital Lock OFF>
15UpdateChapter 3  Output Interfaces3.1.6 ALPHABETS TRANSMISSION Serial Command0005Serial Command 0006      Ignore Case    <Case-Sensitive>3.1.7 DIGITS TRANSMISSION Serial Command0013Serial Command 0014      Numeric Key    <Alphanumeric Key>3.1.8 ALT COMPOSING Serial Command0335Serial Command 0334          Yes    <No> 3.1.9 INTER-CHARACTER DELAY 1) Read this label to specify the inter-character delay.              2) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).   3) Read the “Validate” label on the same page to complete this setting. Serial Command0015    Inter-Character Delay … 3.1.10 LAPTOP SUPPORT Serial Command0389Serial Command 0388         Enable    <Disable>
16Enter Setup Scanner Configuration SmartScan Manual3.2 RS-232 PARAMETERS 3.2.1 ACTIVATE RS-232 INTERFACE Serial Command0001    Activate RS-232 Interface3.2.2 BAUD RATE Serial Command0023Serial Command 0016      115200 bps     38400 bps Serial Command0017Serial Command 0018       19200 bps    <9600 bps> Serial Command0019Serial Command 0020        4800 bps     2400 bps Serial Command0021Serial Command 0022        1200 bps     600 bps (for 1200 only)3.2.3 PARITY Serial Command0028Serial Command 0029      <No Parity>     Even Serial Command0030          Odd
17UpdateChapter 3  Output Interfaces3.2.4 DATA BITS Serial Command0034Serial Command 0035       <8 bits>     7 bits 3.2.5 FLOW CONTROL Serial Command0042Serial Command 0043        <None>     Scanner Ready Serial Command0044Serial Command 0045       Data Ready    Invert Data Ready3.2.6 INTER-CHARACTER DELAY 1) Read this label to specify the inter-character delay.              2) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).   3) Read the “Validate” label on the same page to complete this setting. Serial Command0015    Inter-Character Delay …
18Enter Setup Scanner Configuration SmartScan Manual3.3 WAND EMULATION PARAMETERS (1090+/1100/1105/1200) 3.3.1 ACTIVATE WAND EMULATION Serial Command0306    Activate Wand Emulation3.3.2 NORMAL STATE Serial Command0302Serial Command 0303         High     <Low> 3.3.3 BAR STATE Serial Command0304Serial Command 0305        <High>     Low 3.3.4 MODULE TIME Serial Command0362Serial Command 0363       250 μs  500 μsSerial Command0364Serial Command 0365        <1 ms>     1.5 ms Serial Command0366Serial Command 0367         2 ms     3 ms Serial Command0368Serial Command 0369         4 ms     5 ms
19UpdateChapter 3  Output Interfaces3.3.5 MARGIN TIME Serial Command0370Serial Command 0371         5 ms     10 ms Serial Command0372Serial Command 0373        <20 ms>     30 ms Serial Command0374Serial Command 0375         40 ms     60 ms Serial Command0376Serial Command 0377         80 ms     100 ms
20Enter Setup Scanner Configuration SmartScan Manual
21Update4.1 SELECT READABLE BARCODES CODABARSerial Command0086Serial Command 0087       <Enable>     Disable CODE 39 Serial Command0074Serial Command 0075       <Enable>     Disable CODE 93 Serial Command0088Serial Command 0089       <Enable>     Disable CODE 128 Serial Command0090Serial Command 0091       <Enable>     Disable EAN-128Serial Command0104Serial Command 0105        Enable    <Disable> EAN-13Serial Command0106Serial Command 0107   <Enable No Addon>    Disable No AddonChapter 4SYMBOLOGY SETTINGS
22Enter Setup Scanner Configuration SmartScan ManualSerial Command0108Serial Command 0109    Enable Addon 2    <Disable Addon 2>Serial Command0110Serial Command 0111    Enable Addon 5    <Disable Addon 5>EAN-8Serial Command0098Serial Command 0099   <Enable No Addon>    Disable No AddonSerial Command0100Serial Command 0101    Enable Addon 2    <Disable Addon 2>Serial Command0102Serial Command 0103    Enable Addon 5    <Disable Addon 5>FRENCH PHARMACODE Serial Command0078Serial Command 0079        Enable    <Disable> ITALIAN PHARMACODE Serial Command0076Serial Command 0077        Enable    <Disable> INDUSTRIAL 25 Serial Command0080Serial Command 0081       <Enable>    Disable
23UpdateChapter 4  Symbology SettingsINTERLEAVED 25 Serial Command0082Serial Command 0083       <Enable>     Disable MATRIX 25 Serial Command0084Serial Command 0085        Enable    <Disable> MSI Serial Command0112Serial Command 0113        Enable    <Disable> PLESSEY Serial Command0114Serial Command 0115        Enable    <Disable> RSS-14 & EXPANDED Serial Command0412Serial Command 413  Enable RSS-14 & RSS Expanded <Disable Both> RSS LIMITED Serial Command0414Serial Command 0415        Enable    <Disable> TELEPEN Serial Command0436Serial Command 0437        Enable    <Disable>
24Enter Setup Scanner Configuration SmartScan ManualUPC-ASerial Command0291Serial Command 0292   <Enable No Addon>    Disable No AddonSerial Command0293Serial Command 0294    Enable Addon 2    <Disable Addon 2>Serial Command0295Serial Command 0296    Enable Addon 5    <Disable Addon 5>UPC-ESerial Command0092Serial Command 0093   <Enable No Addon>    Disable No AddonSerial Command0094Serial Command 0095    Enable Addon 2    <Disable Addon 2>Serial Command0096Serial Command 0097    Enable Addon 5    <Disable Addon 5>
25UpdateChapter 4  Symbology Settings4.2 CODABAR PARAMETERS Serial Command0086Serial Command 0087       <Enable>     Disable START / STOP CHARACTERS SELECTION Serial Command0151Serial Command 0152      <abcd/abcd>     abcd/tn*e Serial Command0153Serial Command 0154       ABCD/ABCD     ABCD/TN*E START / STOP TRANSMISSION Serial Command0155Serial Command 0156        Enable     <Disable> CLSI CONVERSION Serial Command0157Serial Command 0158        Enable     <Disable>
26Enter Setup Scanner Configuration SmartScan Manual4.3 CODE 25 PARAMETERS 4.3.1 INDUSTRIAL 25 Serial Command0080Serial Command 0081       <Enable>    Disable START / STOP PATTERN SELECTION Serial Command0130Serial Command 0131    <Industrial 25>     Interleaved 25 Serial Command0132       Matrix 25      CHECKSUM VERIFICATION Serial Command0139Serial Command 0140        Enable     <Disable> CHECKSUM TRANSMISSION Serial Command0141Serial Command 0142       <Enable>     Disable CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).   4) Read the “Validate” label on the same page to complete this setting. Serial Command0208  Enable Max./Min. Length …
27UpdateChapter 4  Symbology SettingsSerial Command0210Serial Command 0211      Max. Length     Min. Length Serial Command0209  Enable Fixed Length …    Serial Command0210Serial Command 0211    Fixed Length 1     Fixed Length 2 4.3.2 INTERLEAVED 25 Serial Command0082Serial Command 0083       <Enable>     Disable START / STOP PATTERN SELECTION Serial Command0133Serial Command 0134     Industrial 25    <Interleaved 25>Serial Command0135       Matrix 25      CHECKSUM VERIFICATION Serial Command0143Serial Command 0144        Enable     <Disable> CHECKSUM TRANSMISSION Serial Command0145Serial Command 0146       <Enable>     Disable
28Enter Setup Scanner Configuration SmartScan ManualCODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).   4) Read the “Validate” label on the same page to complete this setting. Serial Command0212  Enable Max./Min. Length …   Serial Command0214Serial Command 0215      Max. Length     Min. Length Serial Command0213  Enable Fixed Length …    Serial Command0214Serial Command 0215    Fixed Length 1     Fixed Length 2 4.3.3 MATRIX 25 Serial Command0084Serial Command 0085        Enable    <Disable> START / STOP PATTERN SELECTION Serial Command0136Serial Command 0137     Industrial 25    Interleaved 25 Serial Command0138      <Matrix 25>
29UpdateChapter 4  Symbology SettingsCHECKSUM VERIFICATION Serial Command0147Serial Command 0148         Enable     <Disable> CHECKSUM TRANSMISSION Serial Command0149Serial Command 0150        <Enable>     Disable CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).   4) Read the “Validate” label on the same page to complete this setting. Serial Command0216  Enable Max./Min. Length …   Serial Command0218Serial Command 0219      Max. Length     Min. Length Serial Command0217  Enable Fixed Length …    Serial Command0218Serial Command 0219    Fixed Length 1     Fixed Length 2
30Enter Setup Scanner Configuration SmartScan Manual4.4 CODE 39 PARAMETERS Serial Command0074Serial Command 0075       <Enable>     Disable START / STOP TRANSMISSION Serial Command0116Serial Command 0117        Enable     <Disable> CHECKSUM VERIFICATION Serial Command0118Serial Command 0119        Enable     <Disable> CHECKSUM TRANSMISSION Serial Command0120Serial Command 0121       <Enable>     Disable STANDARD / FULL ASCII CODE 39 Serial Command0122Serial Command 0123       Full ASCII     <Standard> 4.5 CODE 93 PARAMETERS Serial Command0088Serial Command 0089       <Enable>     Disable 4.6 CODE 128 PARAMETERS Serial Command0090Serial Command 0091       <Enable>     Disable
31UpdateChapter 4  Symbology Settings4.7 EAN-8 PARAMETERS Serial Command0098Serial Command 0099   <Enable No Addon>    Disable No AddonSerial Command0100Serial Command 0101    Enable Addon 2    <Disable Addon 2>Serial Command0102Serial Command 0103    Enable Addon 5    <Disable Addon 5>CONVERT TO EAN-13 Serial Command0195Serial Command 0196        Enable    <Disable> CHECKSUM TRANSMISSION Serial Command0187Serial Command 0188       <Enable>    Disable
32Enter Setup Scanner Configuration SmartScan Manual4.8 EAN-13 PARAMETERS Serial Command0106Serial Command 0107   <Enable No Addon>    Disable No AddonSerial Command0108Serial Command 0109    Enable Addon 2    <Disable Addon 2>Serial Command0110Serial Command 0111    Enable Addon 5    <Disable Addon 5>ISBN CONVERSION Serial Command0179Serial Command 0180        Enable     <Disable> ISSN CONVERSION Serial Command0181Serial Command 0182        Enable     <Disable> CHECKSUM TRANSMISSION Serial Command0189Serial Command 0190       <Enable>    Disable
33UpdateChapter 4  Symbology Settings4.9 EAN-128 PARAMETERS Serial Command0104Serial Command 0105        Enable    <Disable> CODE ID TRANSMISSION Serial Command0434Serial Command 0435        Enable     <Disable> FIELD SEPARATOR Serial Command0301  Enable Field Separator …   1) Read this label to enable field separator. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string.   3) Read the “Validate” label on the same page to complete this setting.
34Enter Setup Scanner Configuration SmartScan Manual4.10 MSI PARAMETERS Serial Command0112Serial Command 0113        Enable    <Disable> CHECKSUM VERIFICATION Serial Command0167Serial Command 0168  <Single Modulo 10>    Double Modulo 10Serial Command0169    Modulo 10 & 11     CHECKSUM TRANSMISSION Serial Command0170Serial Command 0171  <Last Digit Not    Transmitted> Both Digits TransmittedSerial Command0172  Both Digits Not TransmittedCODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).   4) Read the “Validate” label on the same page to complete this setting. Serial Command0220    Enable Max./Min. Length …
35UpdateChapter 4  Symbology SettingsSerial Command0222Serial Command 0223      Max. Length     Min. Length Serial Command0221  Enable Fixed Length …    Serial Command0222Serial Command 0223    Fixed Length 1     Fixed Length 2
36Enter Setup Scanner Configuration SmartScan Manual4.11 PHARMACODE PARAMETERS 4.11.1 FRENCH PHARMACODE Serial Command0078Serial Command 0079        Enable    <Disable> CHECKSUM TRANSMISSION Serial Command0128Serial Command 0129       <Enable>    Disable 4.11.2 ITALIAN PHARMACODE Serial Command0076Serial Command 0077        Enable    <Disable> CHECKSUM TRANSMISSION Serial Command0126Serial Command 0127       <Enable>    Disable
37UpdateChapter 4  Symbology Settings4.12 PLESSEY PARAMETERS Serial Command0114Serial Command 0115        Enable    <Disable> CONVERT TO UK PLESSEY Serial Command0165Serial Command 0166        Enable    <Disable> CHECKSUM TRANSMISSION Serial Command0163Serial Command 0164       <Enable>    Disable
38Enter Setup Scanner Configuration SmartScan Manual4.13 RSS FAMILY PARAMETERS CODE ID SELECTION Serial Command0432Serial Command 0433          ]C1    <]e0> 4.13.1 RSS-14 Serial Command0412Serial Command 413  Enable RSS-14 & RSS Expanded <Disable Both> CODE ID TRANSMISSION Serial Command0418Serial Command 0419       <Enable>    Disable APPLICATION ID TRANSMISSION Serial Command0424Serial Command 0425       <Enable>    Disable CHECKSUM TRANSMISSION Serial Command0428Serial Command 0429       <Enable>    Disable 4.13.2 RSS LIMITED Serial Command0414Serial Command 0415        Enable    <Disable>
39UpdateChapter 4  Symbology SettingsCODE ID TRANSMISSION Serial Command0420Serial Command 0421       <Enable>    Disable APPLICATION ID TRANSMISSION Serial Command0426Serial Command 0427       <Enable>    Disable CHECKSUM TRANSMISSION Serial Command0430Serial Command 0431       <Enable>    Disable 4.13.3 RSS EXPANDED Serial Command0412Serial Command 413  Enable RSS-14 & RSS Expanded <Disable Both> CODE ID TRANSMISSION Serial Command0422Serial Command 0423       <Enable>    Disable
40Enter Setup Scanner Configuration SmartScan Manual4.14 TELEPEN PARAMETERS Serial Command0436Serial Command 0437        Enable    <Disable> TELEPEN OUTPUT Serial Command0440Serial Command 0441   Original Telepen     (Numeric) <AIM Telepen> APPLY ALL 3 EDITING FORMATS Serial Command0443Serial Command 0444  <Apply All to Telepen>   Disable  All
41UpdateChapter 4  Symbology Settings4.15 UPC-A PARAMETERS Serial Command0291Serial Command 0292   <Enable No Addon>    Disable No AddonSerial Command0293Serial Command 0294    Enable Addon 2    <Disable Addon 2>Serial Command0295Serial Command 0296    Enable Addon 5    <Disable Addon 5>CONVERT TO EAN-13 Serial Command0177Serial Command 0178       <Enable>    Disable SYSTEM NUMBER TRANSMISSION Serial Command0193Serial Command 0194       <Enable>    Disable CHECKSUM TRANSMISSION Serial Command0185Serial Command 0186       <Enable>    Disable
42Enter Setup Scanner Configuration SmartScan Manual4.16 UPC-E PARAMETERS Serial Command0092Serial Command 0093   <Enable No Addon>    Disable No AddonSerial Command0094Serial Command 0095    Enable Addon 2    <Disable Addon 2>Serial Command0096Serial Command 0097    Enable Addon 5    <Disable Addon 5>SYSTEM NUMBER SELECTION Serial Command0287Serial Command 0288  System Number 0 & 1    <System Number 0 Only>CONVERT TO UPC-A Serial Command0175Serial Command 0176        Enable    <Disable> SYSTEM NUMBER TRANSMISSION Serial Command0191Serial Command 0192        Enable    <Disable> CHECKSUM TRANSMISSION Serial Command0183Serial Command 0184       <Enable>    Disable
43Update5.1 CHARACTER SUBSTITUTION 1) Read the label to enable either character substitution by set. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example, read “3”, “0”, “2” and “D” for the scanner to replace the character [0] with a dash [-]. 3) Read the “Validate” label on the same page to complete this setting. Serial Command0309Serial Command 0310         Set 1  Set 2 Serial Command0311         Set 3     5.2 PREFIX/SUFFIX SETTING 1) Read the label to apply prefix code or suffix code separately. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example, read “2” and “B” for the scanner to prefix or suffix the character [+]. 3) Read the “Validate” label on the same page to complete this setting. Serial Command0273Serial Command 0274      Prefix Code   Suffix Code 5.3 CODE ID SETTING 5.3.1 CLEAR CODE ID SETTINGS Serial Command9960  Clear All Code ID   SettingsChapter 5DATA OUTPUT FORMAT
44Enter Setup Scanner Configuration SmartScan Manual5.3.2 SELECT PRE-DEFINED CODE ID Serial Command9961Serial Command 9962     Code ID Set 1    Code ID Set 2 Serial Command9963Serial Command 9964     Code ID Set 3    Code ID Set 4 Serial Command9965     Code ID Set 5     5.3.3 CHANGE CODE ID 1) Read the label of a specific symbology to change its code ID. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example, read “4” and “4” for applying the character [D] for Code ID. 3) Read the “Validate” label on the same page to complete this setting. Serial Command0262Serial Command 0256        Codabar   Code 39 Serial Command0263Serial Command 0264        Code 93    Code 128 Serial Command0266Serial Command 0267         EAN-8   EAN-13 Serial Command0258Serial Command 0257  French Pharmacode         Italian PharmacodeSerial Command0259Serial Command 0260     Industrial 25   Interleaved 25
45UpdateChapter 5    Data Output FormatSerial Command0261Serial Command 0268       Matrix 25   MSI Serial Command0269Serial Command 0442        Plessey   Telepen Serial Command0270Serial Command 0265         UPC-A   UPC-E 5.4 LENGTH CODE SETTING CODABARSerial Command0236Serial Command 0237  Enable Length Code       <Disable Length Code>CODE 39 Serial Command0224Serial Command 0225  Enable Length Code       <Disable Length Code>CODE 93 Serial Command0238Serial Command 0239  Enable Length Code       <Disable Length Code>CODE 128 Serial Command0240Serial Command 0241  Enable Length Code       <Disable Length Code>EAN-128 & RSS FAMILY Serial Command0299Serial Command 0300  Enable Length Code       <Disable Length Code>
46Enter Setup Scanner Configuration SmartScan ManualEAN-8Serial Command0244Serial Command 0245  Enable Length Code       <Disable Length Code>EAN-13Serial Command0246Serial Command 0247  Enable Length Code       <Disable Length Code>FRENCH PHARMACODE Serial Command0228Serial Command 0229  Enable Length Code       <Disable Length Code>ITALIAN PHARMACODE Serial Command0226Serial Command 0227  Enable Length Code       <Disable Length Code>INDUSTRIAL 25 Serial Command0230Serial Command 0231  Enable Length Code       <Disable Length Code>INTERLEAVED 25 Serial Command0232Serial Command 0233  Enable Length Code       <Disable Length Code>MATRIX 25 Serial Command0234Serial Command 0235  Enable Length Code       <Disable Length Code>
47UpdateChapter 5    Data Output FormatMSI Serial Command0248Serial Command 0249  Enable Length Code       <Disable Length Code>PLESSEY Serial Command0250Serial Command 0251  Enable Length Code       <Disable Length Code>TELEPEN Serial Command0438Serial Command 0439  Enable Length Code       <Disable Length Code>UPC-ASerial Command0289Serial Command 0290  Enable Length Code       <Disable Length Code>UPC-ESerial Command0242Serial Command 0243  Enable Length Code       <Disable Length Code>
48Enter Setup Scanner Configuration SmartScan Manual
49Update6.1 FORMAT SELECTION 6.1.1 ACTIVATE EDITING FORMATS FORMAT 1 Serial Command0281Serial Command 0282       Enable Editing Format 1     <Disable Editing Format 1>FORMAT 2 Serial Command0283Serial Command 0284       Enable Editing Format 2     <Disable Editing Format 2>FORMAT 3 Serial Command0285Serial Command 0286       Enable Editing Format 3     <Disable Editing Format 3>APPLY ALL 3 EDITING FORMATS TO TELEPEN Serial Command0443Serial Command 0444  <Apply All to Telepen>   Disable All 6.1.2 EXCLUSIVE DATA EDITING Serial Command0279Serial Command 0280      Reject Non-conforming Data   <Normal> Chapter 6DATA EDITING
50End Format Programming Scanner Configuration SmartScan Manual6.2 EDITING FORMAT PARAMETERS 6.2.1 SELECT FORMAT TO CONFIGURE START FORMAT PROGRAMMING Serial Command9981Serial Command 9982  Configure Format 1          Configure Format 2Serial Command9983  Configure Format 3   END FORMAT PROGRAMMING Serial Command9980  End Format Programming   6.2.2 RESTORE DEFAULT FORMAT Serial Command9990         Restore Default Format   6.2.3 DEFINE DATA CRITERIA APPLICABLE CODE TYPE Serial Command9992Serial Command 9991      <Apply to All Code Types>   Clear All Serial Command0512Serial Command 0500        Codabar   Code 39 Serial Command0514Serial Command 0516        Code 93   Code 128
51UpdateChapter 6  Data EditingSerial Command0524Serial Command 0526    EAN-8 No Addon   EAN-8 Addon 2 Serial Command0528Serial Command 0532     EAN-8 Addon 5   EAN-13 No AddonSerial Command0534Serial Command 0536     EAN-13 Addon 2   EAN-13 Addon 5 Serial Command0590Serial Command 0504     EAN-128 / RSS            French PharmacodeSerial Command0502Serial Command 0506  Italian Pharmacode  Industrial 25 Serial Command0508Serial Command 0510    Interleaved 25   Matrix 25 Serial Command0538Serial Command 0540         MSI   Plessey Serial Command0584Serial Command 0586    UPC-A No Addon   UPC-A Addon 2 Serial Command0588Serial Command 0518     UPC-A Addon 5   UPC-E No Addon Serial Command0520Serial Command 0522     UPC-E Addon 2   UPC-E Addon 5 DATA LENGTH 1) Read the labels for Max. /Min length separately.
52End Format Programming Scanner Configuration SmartScan Manual2) Read the “Decimal Value” label on page 57 for the desired length.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0548Serial Command 0549      Max. Length  Min. Length MATCHING STRING 1) Read the label to specify a matching string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0550  Matching String …   LOCATION OF MATCHING STRING 1) Read the label to specify the location of the matching string. 2) Read the “Decimal Value” label on page 57 for the desired location. 3) Read the “Validate” label on the same page to complete this setting. Serial Command0551  Location of Matching String …   6.2.4 DIVIDE DATA INTO FIELDS TOTAL NUMBER OF FIELDS Serial Command0578Serial Command 0579      <One Field>  Two Fields Serial Command0580Serial Command 0581     Three Fields  Four Fields Serial Command0582Serial Command 0583      Five Fields  Six Fields
53UpdateChapter 6  Data EditingFIELD 1 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0555  Select Field Terminating String …   Serial Command0552Serial Command 0553    Include String            Discard String 1) Read the label to divide field by field length. 2) Read the “Decimal Value” label on page 57 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. Serial Command0554  Divide Field by Field Length …   FIELD 2 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0559  Select Field Terminating String …   Serial Command0556Serial Command 0557    Include String            Discard String 1) Read the label to divide field by field length. 2) Read the “Decimal Value” label on page 57 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting.
54End Format Programming Scanner Configuration SmartScan ManualSerial Command0558  Divide Field by Field Length …   FIELD 3 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0563  Select Field Terminating String …   Serial Command0560Serial Command 0561    Include String            Discard String 1) Read the label to divide field by field length. 2) Read the the “Decimal Value” label on page 57 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. Serial Command0562  Divide Field by Field Length …   FIELD 4 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0567  Select Field Terminating String …   Serial Command0564Serial Command 0565    Include String            Discard String 1) Read the label to divide field by field length. 2) Read the “Decimal Value” label on page 57 for the desired field length.
55UpdateChapter 6  Data Editing3) Read the “Validate” label on the same page to complete this setting. Serial Command0566  Divide Field by Field Length …   FIELD 5 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0571  Select Field Terminating String …   Serial Command0568Serial Command 0569    Include String            Discard String 1) Read the label to divide field by field length. 2) Read the “Decimal Value” label on page 57 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. Serial Command0570  Divide Field by Field Length …   6.2.5 ADDITIONAL FIELDS 1) Read the label to specify an additional field, one at a time. 2) Read the “Hexadecimal Value” label on page 58 for the desired additional field.   3) Read the “Validate” label on the same page to complete this setting. Serial Command0572Serial Command 0573  Additional Field 1…         Additional Field 2…Serial Command0574Serial Command 0575  Additional Field 3…         Additional Field 4…
56End Format Programming Scanner Configuration SmartScan ManualSerial Command0576  Additional Field 5…   6.2.6 FIELD TRANSMISSION SEQUENCE 1) Read the “Start” label to begin with programming the field transmission sequence. 2) Program the transmission sequence by reading the desired fields as well as additional fields. 3) Read the “End” label on the same page to complete this setting. Serial Command 0577        Start (Programming) … Serial Command 9901Serial Command 9902        Field 1                Field 2 Serial Command 9903Serial Command 9904        Field 3                Field 4 Serial Command 9905Serial Command 9906        Field 5                Field 6 Serial Command 9907Serial Command 9908  Additional Field 1        Additional Field 2 Serial Command 9909Serial Command 9910  Additional Field 3        Additional Field 4 Serial Command 9911  Additional Field 5 Serial Command 9994           End (Programming)
57UpdateDECIMAL SYSTEM DECIMAL Serial Command9900Serial Command 9901          0                   1 Serial Command9902Serial Command 9903          2                   3 Serial Command9904Serial Command 9905          4                   5 Serial Command9906Serial Command 9907          6                   7 Serial Command9908Serial Command 9909          8                   9 VALIDATE THE VALUES Serial Command9994                        Validate Appendix INUMERAL SYSTEMS
58Enter Setup Scanner Configuration SmartScan ManualHEXADECIMAL SYSTEM HEXADECIMAL Serial Command9900Serial Command 9901          0                   1 Serial Command9902Serial Command 9903          2                   3 Serial Command9904Serial Command 9905          4                   5 Serial Command9906Serial Command 9907          6                   7 Serial Command9908Serial Command 9909          8                   9 Serial Command9910Serial Command 9911          A                   B Serial Command9912Serial Command 9913          C                   D Serial Command9914Serial Command 9915          E                   F VALIDATE THE VALUES Serial Command9994                        Validate
59KEYBOARD WEDGE TABLE 0 123456780F2 SP 0  @ P  `  p  b1INS F3 !  1  A  Q  a  q  c2DLT F4 "  2 B R b r d3Home F5  #  3  C  S  c  s  e4End F6  $  4  D  T  d  t  f5Up F7 % 5 E U e u g6Down F8  &  6  F  V  f  v  h7Left F9  '  7  G  W g  w  i8BS F10 (  8 H X h x j9HT F11 )  9  I  Y  i  y  kALF F12 * : J Z j z  BRight ESC + ; K [ k {  CPgUp Exec , < L \ l |  DCR CR* - = M ] m }  EPgDn .  > N ^  n ~  FF1 /  ?  O _ o Dly ENTER*Note: (1) b~k: Digits of numeric keypad.       (2) CR*/Send/ENTER*: ENTER key on the numeric keypad. KEY TYPE Serial Command9926Serial Command 9936       <Normal>               Scan Code Note:  If "Keyboard Wedge" is configured for interface, Key Type and Key Status will then become applicable.Appendix IIKEYBOARD WEDGE TABLE & ASCII TABLE
60Scanner Configuration SmartScan ManualKEY STATUS Serial Command9930Serial Command 9931      Add Shift             Add Left Ctrl Serial Command9932Serial Command 9933     Add Left Alt             Add Right CtrlSerial Command9934     Add Right Alt   Note:  Decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. ASCII TABLE 0 12345670   DLE SP 0 @ P `  p  1 SOH DC1 !  1 A Q a q  2 STX DC2 "  2 B R b r  3 ETX DC3 # 3 C S c s   4 EOT DC4 $ 4 D T d t   5 ENQ NAK % 5 E U e u  6 ACK SYN & 6 F V f  v  7 BEL ETB '  7 G W g w  8 BS CAN (  8 H X h x  9 HT EM )  9 I  Y i  y  A LF SUB * : J Z j z  B VT ESC + ; K [ k {  C FF FS , < L \ l |  D CR GS - = M ] m }  E SO RS .  > N ^ n ~  F SI  US /  ?  O _ o DEL
61SERIAL COMMANDS #@nnnn<CR> Purpose  To configure the scanner. Remarks  nnnn – the four digits of command parameters. For example, “9952” is to list the current Code ID settings. “0x23” + “0x40” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d” #@ - - - -<CR> Purpose  To halt the scanner. Remarks  “0x23” + “0x40” + “0x2d” + “0x2d” + “0x2d” + “0x2d” + “0x0d” #@ . . . . <CR> Purpose  To resume operation. Remarks  “0x23” + “0x40” + “0x2e” + “0x2e” + “0x2e” + “0x2e” + “0x0d” #@////<CR> Purpose  To respond with a beep. Remarks  “0x23” + “0x40” + “0x2f” + “0x2f” + “0x2f” + “0x2f” + “0x0d” EXAMPLESend the serial commands via RS-232 interface or Bluetooth SPP. For example, run HyperTerminal on the host computer. For the scanner to change the buzzer frequency to 2 kHz and beep –   #@0048<CR>#@////<CR>For the scanner to change the buzzer frequency to 8 kHz and beep –   #@0046<CR>#@////<CR>Appendix IIIHOST SERIAL COMMANDS
62Scanner Configuration SmartScan ManualFor the scanner to change the buzzer frequency to 4 kHz and beep –   #@0047<CR>#@////<CR>For the scanner to change the buzzer frequency to 1 kHz and beep –   #@0049<CR>#@////<CR>
63HOW TO UPGRADE 1166/1266 FIRMWARE You can only upgrade firmware of one scanner at a time. You must remove the battery of each of the rest scanners when there is more than one scanner connected to your computer, either via (1) the 3666 cradle or (2) the 3667 cradle or any generic Bluetooth dongle. Note:  In case it fails downloading due to low battery, make sure the targe scanner is loaded with a fully charged battery. USING 3666 1) Connect the power supply cord from the 3666 cradle to a proper power outlet. 2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port. 3) Refer to section 1.5 for the target scanner to set connection with the 3666 cradle. Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds. Both labels can be located at the bottom of the cradle. 4) Read the following labels in sequence to configure the scanner to use RS-232 as output interface.  Enter Setup  Activate RS-232 Interface  115200 bps  Update 5) Read the following labels in sequence for the scanner to enter the download mode.   The scanner will respond with beeps to indicate it is ready for downloading. Appendix IVUPGRADING FIRMWARE
64Scanner Configuration SmartScan Manual Enter Setup  Download 6) Run the download utility “ProLoad.exe” or “Download.exe” on your computer.   (Download.exe requires version 2.3 or later!) Open the firmware update “1x66-xx.shx”, and select the correct COM port. Baud rate    – 115,200 bps Data bit     – 8 Parity    – None Flow control    – None   7) The scanner will automatically restart itself when upgrading firmware is completed successfully. USING 3667 OR GENERIC DONGLE 1) Connect the 3667 cradle or any Bluetooth dongle to your computer via the USB port. 2) Refer to section 1.6.1 for the target scanner to establish a connection with your computer via the 3667 cradle or a dongle. Read the following labels in sequence to configure the scanner to use Bluetooth Serial Port as output interface.  Enter Setup   Activate Bluetooth SPP (and read labels for PIN code…)  Update 3) Same as steps 5 ~ 7 above.
65Appendix IV  Upgrading FirmwareHOW TO UPGRADE 3666 FIRMWARE 1) Connect the power supply cord from the 3666 cradle to a proper power outlet. 2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port. 3) Refer to section 1.5 for a scanner to set connection with the 3666 cradle. Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds. Both labels can be located at the bottom of the cradle. 4) Read the following labels in sequence for the 3666 cradle to enter the download mode.   The LED of the cradle will be flashing red and green to indicate it is ready for downloading.  Enter Setup  3666 Download 5) Run the download utility “ProgLoad.exe” or “Download.exe” on your computer.   (Download.exe requires version 2.3 or later!) Open the firmware update “3666*.shx”, and select the correct COM port. Baud rate    – 38,400 bps Data bit     – 8 Parity    – None Flow control    – None   6) The 3666 cradle will automatically restart itself when upgrading firmware is completed successfully.7) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).  Update FIND OUT FIRMWARE VERSION OF 3666 1) Connect the power supply cord from the 3666 cradle to a proper power outlet. 2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port. 3) Refer to section 1.5 for a scanner to set connection with the 3666 cradle. Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds. Both labels can be located at the bottom of the cradle.
66Scanner Configuration SmartScan Manual4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in sequence for the scanner to get the firmware version of the 3666 cradle. If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead.  Enter Setup  Version 5) The current version information of the 3666 cradle will be displayed. For example, Version = V1.06 Oct 01 2003 SN: SW3000014 6) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).  Update
66Scanner Configuration SmartScan Manual4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in sequence for the scanner to get the firmware version of the 3666 cradle. If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead.  Enter Setup  Version 5) The current version information of the 3666 cradle will be displayed. For example, Version = V1.06 Oct 01 2003 SN: SW3000014 6) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).  Update

Navigation menu