CipherLab 36662 Cradle User Manual Scanner Configuration
CipherLab Co., Ltd. Cradle Scanner Configuration
User manual
DOCVersion2.21 Thisdocumentisspecificallydesignedfortheusertoprinttwopagespersheetofpaperwithoptimal printquality. Copyright © 2005~ 2008 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a license agreement containing restrictions on use and disclosure and is also protected by copyright law. Reverse engineering of the software is prohibited. Due to continued product development this information may change without notice. The information and intellectual property contained herein is confidential between CIPHERLAB and the client and remains the exclusive property of CIPHERLAB CO., LTD. If you find any problems in the documentation, please report them to us in writing. CIPHERLAB does not warrant that this document is error-free. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of CIPHERLAB CO., LTD. For product consultancy and technical support, please contact your local sales representative. Also, you may visit our web site for more information. The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD. Microsoft, Windows, and the Windows logo are registered trademarks of Microsoft Corporation in the United States and/or other countries. Bluetooth is a trademark of Bluetooth SIG, Inc., U.S.A. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. The editorial use of these names is for identification as well as to the benefit of the owners, with no intention of infringement. CIPHERLAB CO., LTD. Website: http://www.cipherlab.com RELEASE NOTES VERSION DATE NOTES 2.21 Jan. 02, 2008 Larger setup barcodes 2.20 Nov. 30, 2007 New Word template applied 2.15 Nov.13, 2006 2.14~ Nov. 06, 2006 New: Bluetooth HID supports Japanese keyboard. 2.12 Mar. 03, 2006 2.11 Jan.27, 2006 Modified: Typo errors corrected. 2.10 Jan.18, 2006 Modified: Bluetooth HID doesn’t support the following functions on New: 3667 Bluetooth Cradle for 1166/1266 Modified: Auto-Sense mode supported on 1100 only. New: Appendix III – Host Serial Commands New: Appendix IV – Upgrading Firmware Modified: Add notice for BT SPP and HID power saving – Please disable power saving when connecting more than two 1x66 scanners to Bluetooth dongle. PDAs running Windows CE – Capital Lock Setting: Auto Detection, Digit Transmission: Numeric Key, and Alt Composing. Modified: The default Capital Lock setting of Bluetooth HID is changed from “Auto Detection” to “Capital Lock Off”. 2.00 Dec. 30, 2005 New: Firmware version V4.20 New: Bluetooth HID supported New: Firmware version V4.10 1.00 Oct. 31, 2005 First release CONTENTS RELEASE NOTES .................................................................................................................................. 3 OVERVIEW............................................................................................................................................ 1 Enter Configuration Mode................................................................................................................. 1 Exit Configuration Mode.................................................................................................................... 1 Update Settings............................................................................................................................ 1 Exit without Changes.................................................................................................................... 1 Restore Defaults................................................................................................................................ 1 List Current Settings.......................................................................................................................... 2 BLUETOOTH SETTINGS (1166/1266)................................................................................................. 3 1.1 RF Auto Shutdown (Suspend mode) ......................................................................................... 3 1.2 Power Saving (Sniff Mode) ......................................................................................................... 3 1.3 Transmit Buffer Setting .............................................................................................................. 3 1.4 Memory Mode ............................................................................................................................. 3 1.4.1 Memory Mode .................................................................................................................... 3 1.4.2 Send Data........................................................................................................................... 4 1.4.3 Clear Data........................................................................................................................... 4 1.4.4 Memory Data Delay............................................................................................................ 4 1.5 Set Connection with 3666 ......................................................................................................... 5 1.6 Set Connection with 3667 or Generic Dongle .......................................................................... 5 1.6.1 Bluetooth Serial Port Parameters ..................................................................................... 5 1.6.2 Bluetooth HID Parameters................................................................................................. 6 READER SETTINGS .............................................................................................................................. 9 2.1 Good Read Notification .............................................................................................................. 9 2.1.1 Buzzer Setting .................................................................................................................... 9 2.1.2 Buzzer Frequency............................................................................................................... 9 2.2 Read Redundancy ...................................................................................................................... 9 2.3 Scan Mode .................................................................................................................................. 9 2.4 Auto-Sense Mode (1100 only) .................................................................................................10 2.5 Scanner Time-Out .....................................................................................................................10 2.6 Delay between Re-read ............................................................................................................ 10 2.7 Negative Barcode Setting ........................................................................................................11 OUTPUT INTERFACES......................................................................................................................... 13 3.1 Keyboard Wedge Parameters ..................................................................................................13 3.1.1 Activate and Select Keyboard Type.................................................................................13 3.1.2 Alphabets Layout.............................................................................................................. 14 3.1.3 Digits Layout .....................................................................................................................14 3.1.4 Capital Lock Type ............................................................................................................. 14 3.1.5 Capital Lock Setting .........................................................................................................14 3.1.6 Alphabets Transmission ..................................................................................................15 Scanner Configuration SmartScan Manual 3.1.7 Digits Transmission..........................................................................................................15 3.1.8 ALT Composing................................................................................................................. 15 3.1.9 Inter-Character Delay .......................................................................................................15 3.1.10 Laptop Support ..............................................................................................................15 3.2 RS-232 Parameters..................................................................................................................16 3.2.1 Activate RS-232 Interface ............................................................................................... 16 3.2.2 Baud Rate.........................................................................................................................16 3.2.3 Parity ................................................................................................................................. 16 3.2.4 Data Bits ........................................................................................................................... 17 3.2.5 Flow Control......................................................................................................................17 3.2.6 Inter-Character Delay .......................................................................................................17 3.3 WAND Emulation Parameters (1090+/1100/1105/1200) ................................................. 18 3.3.1 Activate Wand Emulation.................................................................................................18 3.3.2 Normal State ....................................................................................................................18 3.3.3 Bar State........................................................................................................................... 18 3.3.4 Module Time.....................................................................................................................18 3.3.5 Margin Time......................................................................................................................19 SYMBOLOGY SETTINGS..................................................................................................................... 21 4.1 Select Readable Barcodes.......................................................................................................21 4.2 Codabar Parameters ................................................................................................................ 25 4.3 Code 25 Parameters ................................................................................................................ 26 4.3.1 Industrial 25 ..................................................................................................................... 26 4.3.2 Interleaved 25 ..................................................................................................................27 4.3.3 Matrix 25 .......................................................................................................................... 28 4.4 Code 39 Parameters ................................................................................................................ 30 4.5 Code 93 Parameters ................................................................................................................ 30 4.6 Code 128 Parameters..............................................................................................................30 4.7 EAN-8 Parameters ....................................................................................................................31 4.8 EAN-13 Parameters..................................................................................................................32 4.9 EAN-128 Parameters................................................................................................................ 33 4.10 MSI Parameters...................................................................................................................... 34 4.11 Pharmacode Parameters.......................................................................................................36 4.11.1 French Pharmacode ......................................................................................................36 4.11.2 Italian Pharmacode .......................................................................................................36 4.12 Plessey Parameters ............................................................................................................... 37 4.13 RSS Family Parameters ......................................................................................................... 38 4.13.1 RSS-14............................................................................................................................ 38 4.13.2 RSS Limited....................................................................................................................38 4.13.3 RSS Expanded................................................................................................................39 4.14 Telepen Parameters...............................................................................................................40 4.15 UPC-A Parameters ..................................................................................................................41 4.16 UPC-E Parameters .................................................................................................................. 42 DATA OUTPUT FORMAT...................................................................................................................... 43 5.1 Character Substitution .............................................................................................................43 5.2 Prefix/Suffix Setting..................................................................................................................43 Scanner Configuration SmartScan Manual 5.3 Code ID Setting ......................................................................................................................... 43 5.3.1 Clear Code ID Settings .....................................................................................................43 5.3.2 Select Pre-defined Code ID..............................................................................................44 5.3.3 Change Code ID................................................................................................................ 44 5.4 Length Code Setting ................................................................................................................. 45 DATA EDITING .................................................................................................................................... 49 6.1 Format Selection ...................................................................................................................... 49 6.1.1 Activate Editing Formats..................................................................................................49 6.1.2 Exclusive Data Editing......................................................................................................49 6.2 Editing Format Parameters ...................................................................................................... 50 6.2.1 Select Format to Configure..............................................................................................50 6.2.2 Restore Default Format ................................................................................................... 50 6.2.3 Define Data Criteria .........................................................................................................50 6.2.4 Divide Data into Fields.....................................................................................................52 6.2.5 Additional Fields............................................................................................................... 55 6.2.6 Field Transmission Sequence .........................................................................................56 NUMERAL SYSTEMS.......................................................................................................................... 57 Decimal System............................................................................................................................... 57 Hexadecimal System....................................................................................................................... 58 KEYBOARD WEDGE TABLE & ASCII TABLE........................................................................................ 59 Keyboard Wedge Table ...................................................................................................................59 Key Type......................................................................................................................................59 Key Status .................................................................................................................................. 60 ASCII Table....................................................................................................................................... 60 HOST SERIAL COMMANDS ................................................................................................................ 61 Serial Commands ............................................................................................................................ 61 Example ...........................................................................................................................................61 UPGRADING FIRMWARE .................................................................................................................... 63 How to Upgrade 1166/1266 Firmware.........................................................................................63 Using 3666 ................................................................................................................................. 63 Using 3667 or Generic Dongle..................................................................................................64 How to Upgrade 3666 Firmware ....................................................................................................65 Find out Firmware Version of 3666 ..........................................................................................65 OVERVIEW ENTER CONFIGURATION MODE Serial Command N/A Enter Setup EXIT CONFIGURATION MODE UPDATE SETTINGS Serial Command 9999 Update EXIT WITHOUT CHANGES Serial Command 9998 Abort RESTORE DEFAULTS Serial Command 9993 Restore Defaults Note: The default value (if there is) for each setting is included in a pair of angle brackets “<>”. Update Scanner Configuration SmartScan Manual LIST CURRENT SETTINGS Serial Command 9950 List settings regarding Interface, Buzzer, and Scanner Parameters Page 1 Serial Command 9951 List settings regarding Prefix, Postfix, and Length Code Setting Page 2 Serial Command 9952 List settings regarding Code ID Page 3 Serial Command 9953 List settings regarding: Readable Symbologies Page 4 Serial Command 9954 List settings regarding Symbology Parameters (1/3) Page 5 Serial Command 9955 List settings regarding Symbology Parameters (2/3) Page 6 Serial Command 9956 List settings regarding Symbology Parameters (3/3) Page 7 Serial Command 9957 List settings regarding Editing Format 1 Page 8 Serial Command 9958 List settings regarding Editing Format 2 Page 9 Serial Command 9959 List settings regarding Editing Format 3 Page 10 Enter Setup Chapter 1 BLUETOOTH SETTINGS (1166/1266) 1.1 RF AUTO SHUTDOWN (SUSPEND MODE) 1) Read this label to specify the time interval before the scanner enters suspend mode. 2) Read the “Decimal Value” label on page 57. For example, read “1” and “5” for the scanner to suspend the connection with 3666 after being idle for 15 minutes. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0445 RF Auto Shutdown after … minutes 1.2 POWER SAVING (SNIFF MODE) Serial Command 0459 Serial Command 0458Disable 1.3 TRANSMIT BUFFER SETTING Serial Command 0386 Serial Command 0387 Enable 1.4 MEMORY MODE 1.4.1 MEMORY MODE Serial Command 0321 Serial Command 0320 Enable Update Scanner Configuration SmartScan Manual 1.4.2 SEND DATA Serial Command 9918 Send Data 1.4.3 CLEAR DATA 1) Read the “Clear Data” label to clear the flash memory. 2) Read the “Confirm” label to confirm the action. Serial Command 9916 Serial Command 9917 Clear Data Confirm 1.4.4 MEMORY DATA DELAY Serial Command 0323 Serial Command 0322 250 ms Serial Command 0325 Serial Command 0324 500 ms Serial Command 0326 1 sec Serial Command 0327 2 sec 3 sec Serial Command 0329 Serial Command 0328 5 sec 8 sec Enter Setup Chapter 1 Bluetooth Settings (1166/1266) 1.5 SET CONNECTION WITH 3666 1) Read this label or the same one at the bottom of the 3666 cradle. 2) Read the “Serial Number” label at the bottom of the cradle within 5 seconds. 3) Proceed to select a desired output interface. Serial Command Set Connection 1.6 SET CONNECTION WITH 3667 OR GENERIC DONGLE 1.6.1 BLUETOOTH SERIAL PORT PARAMETERS Serial Command 0453 Activate Bluetooth SPP DEVICE NAME BROADCASTING Serial Command 0451 Serial Command 0450 No AUTHENTICATION Serial Command 0448 Serial Command 0449 Yes PIN CODE 1) Read this label to specify the PIN code. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string (max. 6 characters are allowed). 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0452 Enter PIN Code … Update Scanner Configuration SmartScan Manual 1.6.2 BLUETOOTH HID PARAMETERS 1) Read this label to activate Bluetooth HID and select a keyboard type. 2) Read the “Decimal Value” label on page 57. Refer to the table below for the number of desired keyboard type. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0000 Activate & Select Keyboard Type … NO. KEYBOARD TYPE NO. KEYBOARD TYPE 64 PCAT (US) 70 PCAT (UK) 65 PCAT (French) 71 PCAT (Belgium) 66 PCAT (German) 72 PCAT (Spanish) 67 PCAT (Italian) 73 PCAT (Portuguese) 68 PCAT (Swedish) 74 PS55 A01-2 (Japanese) 69 PCAT (Norwegian) RESET CONNECTION Read this label when switching connection from one PC to another and re-connection is required. Serial Command 9972 Reset Connection DEVICE NAME BROADCASTING Serial Command 0451 Serial Command 0450 No AUTHENTICATION Serial Command 0449 Serial Command 0448 Yes Enter Setup Chapter 1 Bluetooth Settings (1166/1266) PIN CODE 1) Read this label to specify the PIN code. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string (max. 6 characters are allowed). 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0452 Enter PIN Code … ALPHABETS LAYOUT Serial Command 0313 Serial Command 0312 AZERTY Serial Command 0314 QWERTZ DIGITS LAYOUT Serial Command 0008 Serial Command 0007 Upper Row Serial Command 0009 Lower Row CAPITAL LOCK TYPE Serial Command 0011 Serial Command 0010 Shift Lock Serial Command 0012 Capital Lock Update Scanner Configuration SmartScan Manual CAPITAL LOCK SETTING Serial Command 0003 Serial Command 0002 Auto Detection Capital Lock ON Serial Command 0004 ALPHABETS TRANSMISSION Serial Command 0006 Serial Command 0005 Ignore Case DIGITS TRANSMISSION Serial Command 0014 Serial Command 0013 Numeric Key ALT COMPOSING Serial Command 0334 Serial Command 0335 Yes Enter Setup Chapter 2 READER SETTINGS 2.1 GOOD READ NOTIFICATION 2.1.1 BUZZER SETTING Serial Command 0319 Serial Command 0318 Disable Buzzer 2.1.2 BUZZER FREQUENCY Serial Command 0047 Serial Command 0046 8 kHz <4 kHz> Serial Command 0049 Serial Command 0048 2 kHz 1 kHz 2.2 READ REDUNDANCY Serial Command 0202 Serial Command 0201 Serial Command 0203 One Time Serial Command 0204 Two Times Three Times 2.3 SCAN MODE Serial Command 0067 Serial Command 0066 Continuous Mode (Default for 1000/1090+) Update Scanner Configuration SmartScan Manual Serial Command 0069 Serial Command 0068 Auto Power Off Mode Serial Command 0070 Alternate Mode Serial Command 0071 Momentary Mode Repeat Mode Serial Command 0073 Serial Command 0072 Test Mode (Default for 1100/1105/1166/1200/1266) 2.4 AUTO-SENSE MODE (1100 ONLY) Serial Command 0333 Serial Command 0332 Enable 2.5 SCANNER TIME-OUT 1) Read this label to specify the time interval before the scan engine times out in Laser, Auto Off, or Auto Power Off mode. 2) Read the “Decimal Value” label on page 57. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 10 seconds. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0207 Scanner Time-Out after … seconds 2.6 DELAY BETWEEN RE-READ Serial Command 0337 Serial Command 0336 100 ms 200 ms 10 Enter Setup Chapter 2 Reader Settings Serial Command 0339 Serial Command 0338 <400 ms> 800 ms Serial Command 0341 Serial Command 0340 1 sec 2 sec Serial Command 0343 Serial Command 0342 3 sec 5 sec 2.7 NEGATIVE BARCODE SETTING Serial Command 0200 Serial Command 0199 Enable 11 Update Scanner Configuration SmartScan Manual 12 Enter Setup Chapter 3 OUTPUT INTERFACES 3.1 KEYBOARD WEDGE PARAMETERS 3.1.1 ACTIVATE AND SELECT KEYBOARD TYPE 1) Read this label to activate Keyboard Wedge and select a keyboard type. 2) Read the “Decimal Value” label on page 57. Refer to the table below for the number of desired keyboard type. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0000 Activate & Select Keyboard Type … NO. KEYBOARD TYPE NO. KEYBOARD TYPE PCAT (US) 15 PS55 001-81 PCAT (French) 16 PS55 001-2 PCAT (German) 17 PS55 001-82 PCAT (Italian) 18 PS55 001-3 PCAT (Swedish) 19 PS55 001-8A PCAT (Norwegian) 20 PS55 002-1, 003-1 PCAT (UK) 21 PS55 002-81, 003-81 PCAT (Belgium) 22 PS55 002-2, 003-2 PCAT (Spanish) 23 PS55 002-82, 003-82 10 PCAT (Portuguese) 24 PS55 002-3, 003-3 11 PS55 A01-1 25 PS55 002-8A, 003-8A 12 PS55 A01-2 (Japanese) 26 IBM 3477 Type 4 (Japanese) 13 PS55 A01-3 27 PS2-30 14 PS55 001-1 28 IBM 34XX/319X, Memorex Telex 122 Keys 13 Update Scanner Configuration SmartScan Manual 3.1.2 ALPHABETS LAYOUT Serial Command 0313 Serial Command 0312 AZERTY Serial Command 0314 QWERTZ 3.1.3 DIGITS LAYOUT Serial Command 0008 Serial Command 0007 Upper Row Serial Command 0009 Lower Row 3.1.4 CAPITAL LOCK TYPE Serial Command 0011 Serial Command 0010 Shift Lock Serial Command 0012 Capital Lock 3.1.5 CAPITAL LOCK SETTING Serial Command 0003 Serial Command 0002 Auto Detection Capital Lock ON Serial Command 0004 14 Enter Setup Chapter 3 Output Interfaces 3.1.6 ALPHABETS TRANSMISSION Serial Command 0006 Serial Command 0005 Ignore Case 3.1.7 DIGITS TRANSMISSION Serial Command 0014 Serial Command 0013 Numeric Key 3.1.8 ALT COMPOSING Serial Command 0334 Serial Command 0335 Yes 3.1.9 INTER-CHARACTER DELAY 1) Read this label to specify the inter-character delay. 2) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond). 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0015 Inter-Character Delay … 3.1.10 LAPTOP SUPPORT Serial Command 0388 Serial Command 0389 Enable 15 Update Scanner Configuration SmartScan Manual 3.2 RS-232 PARAMETERS 3.2.1 ACTIVATE RS-232 INTERFACE Serial Command 0001 Activate RS-232 Interface 3.2.2 BAUD RATE Serial Command 0016 Serial Command 0023 115200 bps Serial Command 0017 38400 bps Serial Command 0018 19200 bps <9600 bps> Serial Command 0020 Serial Command 0019 4800 bps 2400 bps Serial Command 0022 Serial Command 0021 1200 bps 600 bps (for 1200 only) 3.2.3 PARITY Serial Command 0029 Serial Command 0028 Even Serial Command 0030 Odd 16 Enter Setup Chapter 3 Output Interfaces 3.2.4 DATA BITS Serial Command 0035 Serial Command 0034 <8 bits> 7 bits 3.2.5 FLOW CONTROL Serial Command 0043 Serial Command 0042 Scanner Ready Serial Command 0045 Serial Command 0044 Data Ready Invert Data Ready 3.2.6 INTER-CHARACTER DELAY 1) Read this label to specify the inter-character delay. 2) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond). 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0015 Inter-Character Delay … 17 Update Scanner Configuration SmartScan Manual 3.3 WAND EMULATION PARAMETERS (1090+/1100/1105/1200) 3.3.1 ACTIVATE WAND EMULATION Serial Command 0306 Activate Wand Emulation 3.3.2 NORMAL STATE Serial Command 0303 Serial Command 0302 High 3.3.3 BAR STATE Serial Command 0305 Serial Command 0304 Low 3.3.4 MODULE TIME Serial Command 0363 Serial Command 0362 250 μs Serial Command 0364 500 μs Serial Command 0365 <1 ms> 1.5 ms Serial Command 0367 Serial Command 0366 2 ms 3 ms Serial Command 0369 Serial Command 0368 4 ms 5 ms 18 Enter Setup Chapter 3 Output Interfaces 3.3.5 MARGIN TIME Serial Command 0371 Serial Command 0370 5 ms 10 ms Serial Command 0373 Serial Command 0372 <20 ms> Serial Command 0374 30 ms Serial Command 0375 40 ms 60 ms Serial Command 0377 Serial Command 0376 80 ms 100 ms 19 Update Scanner Configuration SmartScan Manual 20 Enter Setup Chapter 4 SYMBOLOGY SETTINGS 4.1 SELECT READABLE BARCODES CODABAR Serial Command 0087 Serial Command 0086 Disable CODE 39 Serial Command 0075 Serial Command 0074 Disable CODE 93 Serial Command 0089 Serial Command 0088 Disable CODE 128 Serial Command 0091 Serial Command 0090 Disable EAN-128 Serial Command 0105 Serial Command 0104 Enable EAN-13 Serial Command 0107 Serial Command 0106 Disable No Addon 21 Update Scanner Configuration SmartScan Manual Serial Command 0109 Serial Command 0108 Enable Addon 2 Serial Command 0110 Serial Command 0111 Enable Addon 5 EAN-8 Serial Command 0099 Serial Command 0098 Disable No Addon Serial Command 0101 Serial Command 0100 Enable Addon 2 Serial Command 0102 Serial Command 0103 Enable Addon 5 FRENCH PHARMACODE Serial Command 0079 Serial Command 0078 Enable ITALIAN PHARMACODE Serial Command 0077 Serial Command 0076 Enable INDUSTRIAL 25 Serial Command 0081 Serial Command 0080 Disable 22 Enter Setup Chapter 4 Symbology Settings INTERLEAVED 25 Serial Command 0083 Serial Command 0082 Disable MATRIX 25 Serial Command 0085 Serial Command 0084 Enable MSI Serial Command 0113 Serial Command 0112 Enable PLESSEY Serial Command 0115 Serial Command 0114 Enable RSS-14 & EXPANDED Serial Command 413 Serial Command 0412 Enable RSS-14 & RSS Expanded RSS LIMITED Serial Command 0415 Serial Command 0414 Enable TELEPEN Serial Command 0437 Serial Command 0436 Enable 23 Update Scanner Configuration SmartScan Manual UPC-A Serial Command 0292 Serial Command 0291 Serial Command 0293 Disable No Addon Serial Command 0294 Enable Addon 2 Serial Command 0296 Serial Command 0295 Enable Addon 5 UPC-E Serial Command 0093 Serial Command 0092 Serial Command 0094 Disable No Addon Serial Command 0095 Enable Addon 2 Serial Command 0097 Serial Command 0096 Enable Addon 5 24 Enter Setup Chapter 4 Symbology Settings 4.2 CODABAR PARAMETERS Serial Command 0087 Serial Command 0086 Disable START / STOP CHARACTERS SELECTION Serial Command 0152 Serial Command 0151 abcd/tn*e Serial Command 0154 Serial Command 0153 ABCD/ABCD ABCD/TN*E START / STOP TRANSMISSION Serial Command 0156 Serial Command 0155 Enable CLSI CONVERSION Serial Command 0158 Serial Command 0157 Enable 25 Update Scanner Configuration SmartScan Manual 4.3 CODE 25 PARAMETERS 4.3.1 INDUSTRIAL 25 Serial Command 0081 Serial Command 0080 Disable START / STOP PATTERN SELECTION Serial Command 0131 Serial Command 0130 Interleaved 25 Serial Command 0132 Matrix 25 CHECKSUM VERIFICATION Serial Command 0140 Serial Command 0139 Enable CHECKSUM TRANSMISSION Serial Command 0142 Serial Command 0141 Disable CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond). 4) Read the “Validate” label on the same page to complete this setting. Serial Command 0208 Enable Max./Min. Length … 26 Enter Setup Chapter 4 Symbology Settings Serial Command 0211 Serial Command 0210 Max. Length Min. Length Serial Command 0209 Serial Command 0210 Enable Fixed Length … Serial Command 0211 Fixed Length 1 Fixed Length 2 4.3.2 INTERLEAVED 25 Serial Command 0083 Serial Command 0082 Disable START / STOP PATTERN SELECTION Serial Command 0134 Serial Command 0133 Industrial 25 Serial Command 0135 Matrix 25 CHECKSUM VERIFICATION Serial Command 0144 Serial Command 0143 Enable CHECKSUM TRANSMISSION Serial Command 0146 Serial Command 0145 Disable 27 Update Scanner Configuration SmartScan Manual CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond). 4) Read the “Validate” label on the same page to complete this setting. Serial Command 0212 Serial Command 0214 Enable Max./Min. Length … Serial Command 0215 Max. Length Min. Length Serial Command 0213 Serial Command 0214 Enable Fixed Length … Serial Command 0215 Fixed Length 1 Fixed Length 2 4.3.3 MATRIX 25 Serial Command 0085 Serial Command 0084 Enable START / STOP PATTERN SELECTION Serial Command 0137 Serial Command 0136 Industrial 25 Interleaved 25 Serial Command 0138 28 Enter Setup Chapter 4 Symbology Settings CHECKSUM VERIFICATION Serial Command 0148 Serial Command 0147 Enable CHECKSUM TRANSMISSION Serial Command 0150 Serial Command 0149 Disable CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond). 4) Read the “Validate” label on the same page to complete this setting. Serial Command 0216 Serial Command 0218 Enable Max./Min. Length … Serial Command 0219 Max. Length Min. Length Serial Command 0217 Serial Command 0218 Enable Fixed Length … Serial Command 0219 Fixed Length 1 Fixed Length 2 29 Update Scanner Configuration SmartScan Manual 4.4 CODE 39 PARAMETERS Serial Command 0075 Serial Command 0074 Disable START / STOP TRANSMISSION Serial Command 0117 Serial Command 0116 Enable CHECKSUM VERIFICATION Serial Command 0119 Serial Command 0118 Enable CHECKSUM TRANSMISSION Serial Command 0121 Serial Command 0120 Disable STANDARD / FULL ASCII CODE 39 Serial Command 0123 Serial Command 0122 Full ASCII 4.5 CODE 93 PARAMETERS Serial Command 0089 Serial Command 0088 Disable 4.6 CODE 128 PARAMETERS Serial Command 0091 Serial Command 0090 Disable 30 Enter Setup Chapter 4 Symbology Settings 4.7 EAN-8 PARAMETERS Serial Command 0099 Serial Command 0098 Serial Command 0100 Disable No Addon Serial Command 0101 Enable Addon 2 Serial Command 0103 Serial Command 0102 Enable Addon 5 CONVERT TO EAN-13 Serial Command 0196 Serial Command 0195 Enable CHECKSUM TRANSMISSION Serial Command 0188 Serial Command 0187 Disable 31 Update Scanner Configuration SmartScan Manual 4.8 EAN-13 PARAMETERS Serial Command 0107 Serial Command 0106 Serial Command 0108 Disable No Addon Serial Command 0109 Enable Addon 2 Serial Command 0111 Serial Command 0110 Enable Addon 5 ISBN CONVERSION Serial Command 0180 Serial Command 0179 Enable ISSN CONVERSION Serial Command 0181 Serial Command 0182 Enable CHECKSUM TRANSMISSION Serial Command 0190 Serial Command 0189 Disable 32 Enter Setup Chapter 4 Symbology Settings 4.9 EAN-128 PARAMETERS Serial Command 0105 Serial Command 0104 Enable CODE ID TRANSMISSION Serial Command 0435 Serial Command 0434 Enable FIELD SEPARATOR Serial Command 0301 Enable Field Separator … 1) Read this label to enable field separator. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. 33 Update Scanner Configuration SmartScan Manual 4.10 MSI PARAMETERS Serial Command 0113 Serial Command 0112 Enable CHECKSUM VERIFICATION Serial Command 0168 Serial Command 0167 Double Modulo 10 Serial Command 0169 Modulo 10 & 11 CHECKSUM TRANSMISSION Serial Command 0171 Serial Command 0170 Both Digits Transmitted Serial Command 0172 Both Digits Not Transmitted CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond). 4) Read the “Validate” label on the same page to complete this setting. Serial Command 0220 Enable Max./Min. Length … 34 Enter Setup Chapter 4 Symbology Settings Serial Command 0223 Serial Command 0222 Max. Length Min. Length Serial Command 0221 Serial Command 0222 Enable Fixed Length … Serial Command 0223 Fixed Length 1 Fixed Length 2 35 Update Scanner Configuration SmartScan Manual 4.11 PHARMACODE PARAMETERS 4.11.1 FRENCH PHARMACODE Serial Command 0079 Serial Command 0078 Enable CHECKSUM TRANSMISSION Serial Command 0129 Serial Command 0128 Disable 4.11.2 ITALIAN PHARMACODE Serial Command 0077 Serial Command 0076 Enable CHECKSUM TRANSMISSION Serial Command 0127 Serial Command 0126 Disable 36 Enter Setup Chapter 4 Symbology Settings 4.12 PLESSEY PARAMETERS Serial Command 0115 Serial Command 0114 Enable CONVERT TO UK PLESSEY Serial Command 0166 Serial Command 0165 Enable CHECKSUM TRANSMISSION Serial Command 0164 Serial Command 0163 Disable 37 Update Scanner Configuration SmartScan Manual 4.13 RSS FAMILY PARAMETERS CODE ID SELECTION Serial Command 0433 Serial Command 0432 ]C1 <]e0> 4.13.1 RSS-14 Serial Command 413 Serial Command 0412 Enable RSS-14 & RSS Expanded CODE ID TRANSMISSION Serial Command 0419 Serial Command 0418 Disable APPLICATION ID TRANSMISSION Serial Command 0425 Serial Command 0424 Disable CHECKSUM TRANSMISSION Serial Command 0429 Serial Command 0428 Disable 4.13.2 RSS LIMITED Serial Command 0415 Serial Command 0414 Enable 38 Enter Setup Chapter 4 Symbology Settings CODE ID TRANSMISSION Serial Command 0421 Serial Command 0420 Disable APPLICATION ID TRANSMISSION Serial Command 0427 Serial Command 0426 Disable CHECKSUM TRANSMISSION Serial Command 0431 Serial Command 0430 Disable 4.13.3 RSS EXPANDED Serial Command 413 Serial Command 0412 Enable RSS-14 & RSS Expanded CODE ID TRANSMISSION Serial Command 0423 Serial Command 0422 Disable 39 Update Scanner Configuration SmartScan Manual 4.14 TELEPEN PARAMETERS Serial Command 0437 Serial Command 0436 Enable TELEPEN OUTPUT Serial Command 0441 Serial Command 0440 Original Telepen (Numeric) APPLY ALL 3 EDITING FORMATS Serial Command 0443 Serial Command 0444 Disable All 40 Enter Setup Chapter 4 Symbology Settings 4.15 UPC-A PARAMETERS Serial Command 0292 Serial Command 0291 Serial Command 0293 Disable No Addon Serial Command 0294 Enable Addon 2 Serial Command 0296 Serial Command 0295 Enable Addon 5 CONVERT TO EAN-13 Serial Command 0177 Serial Command 0178 Disable SYSTEM NUMBER TRANSMISSION Serial Command 0193 Serial Command 0194 Disable CHECKSUM TRANSMISSION Serial Command 0185 Serial Command 0186 Disable 41 Update Scanner Configuration SmartScan Manual 4.16 UPC-E PARAMETERS Serial Command 0093 Serial Command 0092 Serial Command 0094 Disable No Addon Serial Command 0095 Enable Addon 2 Serial Command 0097 Serial Command 0096 Enable Addon 5 SYSTEM NUMBER SELECTION Serial Command 0287 Serial Command 0288 System Number 0 & 1 CONVERT TO UPC-A Serial Command 0175 Serial Command 0176 Enable SYSTEM NUMBER TRANSMISSION Serial Command 0191 Serial Command 0192 Enable CHECKSUM TRANSMISSION Serial Command 0183 Serial Command 0184 Disable 42 Enter Setup Chapter 5 DATA OUTPUT FORMAT 5.1 CHARACTER SUBSTITUTION 1) Read the label to enable either character substitution by set. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example, read “3”, “0”, “2” and “D” for the scanner to replace the character [0] with a dash [-]. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0310 Serial Command 0309 Set 1 Set 2 Serial Command 0311 Set 3 5.2 PREFIX/SUFFIX SETTING 1) Read the label to apply prefix code or suffix code separately. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example, read “2” and “B” for the scanner to prefix or suffix the character [+]. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0274 Serial Command 0273 Prefix Code Suffix Code 5.3 CODE ID SETTING 5.3.1 CLEAR CODE ID SETTINGS Serial Command 9960 Clear All Code ID Settings 43 Update Scanner Configuration SmartScan Manual 5.3.2 SELECT PRE-DEFINED CODE ID Serial Command 9962 Serial Command 9961 Code ID Set 1 Code ID Set 2 Serial Command 9964 Serial Command 9963 Code ID Set 3 Code ID Set 4 Serial Command 9965 Code ID Set 5 5.3.3 CHANGE CODE ID 1) Read the label of a specific symbology to change its code ID. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example, read “4” and “4” for applying the character [D] for Code ID. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0256 Serial Command 0262 Codabar Serial Command 0263 Code 39 Serial Command 0264 Code 93 Code 128 Serial Command 0267 Serial Command 0266 EAN-8 EAN-13 Serial Command 0257 Serial Command 0258 French Pharmacode Serial Command 0259 Italian Pharmacode Serial Command 0260 Industrial 25 Interleaved 25 44 Enter Setup Chapter 5 Data Output Format Serial Command 0268 Serial Command 0261 Matrix 25 Serial Command 0269 MSI Serial Command 0442 Plessey Telepen Serial Command 0265 Serial Command 0270 UPC-A UPC-E 5.4 LENGTH CODE SETTING CODABAR Serial Command 0237 Serial Command 0236 Enable Length Code CODE 39 Serial Command 0225 Serial Command 0224 Enable Length Code CODE 93 Serial Command 0239 Serial Command 0238 Enable Length Code CODE 128 Serial Command 0241 Serial Command 0240 Enable Length Code EAN-128 & RSS FAMILY Serial Command 0300 Serial Command 0299 Enable Length Code 45 Update Scanner Configuration SmartScan Manual EAN-8 Serial Command 0245 Serial Command 0244 Enable Length Code EAN-13 Serial Command 0247 Serial Command 0246 Enable Length Code FRENCH PHARMACODE Serial Command 0229 Serial Command 0228 Enable Length Code ITALIAN PHARMACODE Serial Command 0227 Serial Command 0226 Enable Length Code INDUSTRIAL 25 Serial Command 0231 Serial Command 0230 Enable Length Code INTERLEAVED 25 Serial Command 0233 Serial Command 0232 Enable Length Code MATRIX 25 Serial Command 0235 Serial Command 0234 Enable Length Code 46 Enter Setup Chapter 5 Data Output Format MSI Serial Command 0249 Serial Command 0248 Enable Length Code PLESSEY Serial Command 0251 Serial Command 0250 Enable Length Code TELEPEN Serial Command 0439 Serial Command 0438 Enable Length Code UPC-A Serial Command 0290 Serial Command 0289 Enable Length Code UPC-E Serial Command 0243 Serial Command 0242 Enable Length Code 47 Update Scanner Configuration SmartScan Manual 48 Enter Setup Chapter 6 DATA EDITING 6.1 FORMAT SELECTION 6.1.1 ACTIVATE EDITING FORMATS FORMAT 1 Serial Command 0282 Serial Command 0281 Enable Editing Format 1 FORMAT 2 Serial Command 0284 Serial Command 0283 Enable Editing Format 2 FORMAT 3 Serial Command 0286 Serial Command 0285 Enable Editing Format 3 APPLY ALL 3 EDITING FORMATS TO TELEPEN Serial Command 0444 Serial Command 0443 Disable All 6.1.2 EXCLUSIVE DATA EDITING Serial Command 0279 Serial Command 0280 Reject Non-conforming Data 49 Update Scanner Configuration SmartScan Manual 6.2 EDITING FORMAT PARAMETERS 6.2.1 SELECT FORMAT TO CONFIGURE START FORMAT PROGRAMMING Serial Command 9982 Serial Command 9981 Configure Format 1 Configure Format 2 Serial Command 9983 Configure Format 3 END FORMAT PROGRAMMING Serial Command 9980 End Format Programming 6.2.2 RESTORE DEFAULT FORMAT Serial Command 9990 Restore Default Format 6.2.3 DEFINE DATA CRITERIA APPLICABLE CODE TYPE Serial Command 9991 Serial Command 9992 Serial Command Serial Command 0500 0512 Codabar Serial Command 0514 Clear All Code 39 Serial Command 0516 Code 93 Code 128 50 End Format Programming Chapter 6 Data Editing Serial Command 0526 Serial Command 0524 EAN-8 No Addon Serial Command 0528 EAN-8 Addon 2 Serial Command 0532 EAN-8 Addon 5 EAN-13 No Addon Serial Command 0536 Serial Command 0534 EAN-13 Addon 2 EAN-13 Addon 5 Serial Command 0504 Serial Command 0590 EAN-128 / RSS Serial Command 0502 French Pharmacode Serial Command 0506 Italian Pharmacode Industrial 25 Serial Command 0510 Serial Command 0508 Interleaved 25 Matrix 25 Serial Command 0540 Serial Command 0538 MSI Serial Command 0584 Plessey Serial Command 0586 UPC-A No Addon UPC-A Addon 2 Serial Command 0518 Serial Command 0588 UPC-A Addon 5 UPC-E No Addon Serial Command 0522 Serial Command 0520 UPC-E Addon 2 UPC-E Addon 5 DATA LENGTH 1) Read the labels for Max. /Min length separately. 51 Update Scanner Configuration SmartScan Manual 2) Read the “Decimal Value” label on page 57 for the desired length. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0549 Serial Command 0548 Max. Length Min. Length MATCHING STRING 1) Read the label to specify a matching string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0550 Matching String … LOCATION OF MATCHING STRING 1) Read the label to specify the location of the matching string. 2) Read the “Decimal Value” label on page 57 for the desired location. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0551 Location of Matching String … 6.2.4 DIVIDE DATA INTO FIELDS TOTAL NUMBER OF FIELDS Serial Command 0579 Serial Command 0578 Two Fields Serial Command 0581 Serial Command 0580 Three Fields Serial Command 0582 Four Fields Serial Command 0583 Five Fields Six Fields 52 End Format Programming Chapter 6 Data Editing FIELD 1 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0555 Select Field Terminating String … Serial Command Serial Command 0553 0552 Include String Discard String 1) Read the label to divide field by field length. 2) Read the “Decimal Value” label on page 57 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0554 Divide Field by Field Length … FIELD 2 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0559 Select Field Terminating String … Serial Command Serial Command 0557 0556 Include String Discard String 1) Read the label to divide field by field length. 2) Read the “Decimal Value” label on page 57 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. 53 Update Scanner Configuration SmartScan Manual Serial Command 0558 Divide Field by Field Length … FIELD 3 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0563 Select Field Terminating String … Serial Command Serial Command 0561 0560 Include String Discard String 1) Read the label to divide field by field length. 2) Read the the “Decimal Value” label on page 57 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0562 Divide Field by Field Length … FIELD 4 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0567 Select Field Terminating String … Serial Command Serial Command 0565 0564 Include String Discard String 1) Read the label to divide field by field length. 2) Read the “Decimal Value” label on page 57 for the desired field length. 54 End Format Programming Chapter 6 Data Editing 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0566 Divide Field by Field Length … FIELD 5 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0571 Select Field Terminating String … Serial Command Serial Command 0569 0568 Include String Discard String 1) Read the label to divide field by field length. 2) Read the “Decimal Value” label on page 57 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0570 Divide Field by Field Length … 6.2.5 ADDITIONAL FIELDS 1) Read the label to specify an additional field, one at a time. 2) Read the “Hexadecimal Value” label on page 58 for the desired additional field. 3) Read the “Validate” label on the same page to complete this setting. Serial Command Serial Command 0572 0573 Additional Field 1… Serial Command 0574 Additional Field 2… Serial Command 0575 Additional Field 3… Additional Field 4… 55 Update Scanner Configuration SmartScan Manual Serial Command 0576 Additional Field 5… 6.2.6 FIELD TRANSMISSION SEQUENCE 1) Read the “Start” label to begin with programming the field transmission sequence. 2) Program the transmission sequence by reading the desired fields as well as additional fields. 3) Read the “End” label on the same page to complete this setting. Serial Command 0577 Start (Programming) … Serial Command 9901 Serial Command 9902 Field 1 Field 2 Serial Command 9904 Serial Command 9903 Field 3 Field 4 Serial Command 9906 Serial Command 9905 Field 5 Field 6 Serial Command 9907 Serial Command 9908 Additional Field 1 Additional Field 2 Serial Command 9910 Additional Field 3 Additional Field 4 Serial Command 9909 Serial Command 9911 Additional Field 5 Serial Command 9994 End (Programming) 56 End Format Programming Appendix I NUMERAL SYSTEMS DECIMAL SYSTEM DECIMAL Serial Command 9901 Serial Command 9900 Serial Command 9902 Serial Command 9903 Serial Command 9905 Serial Command 9904 Serial Command 9907 Serial Command 9906 Serial Command 9908 Serial Command 9909 VALIDATE THE VALUES Serial Command 9994 Validate 57 Update Scanner Configuration SmartScan Manual HEXADECIMAL SYSTEM HEXADECIMAL Serial Command 9901 Serial Command 9900 Serial Command 9902 Serial Command 9903 Serial Command 9905 Serial Command 9904 Serial Command 9907 Serial Command 9906 Serial Command 9908 Serial Command 9909 Serial Command 9911 Serial Command 9910 Serial Command 9913 Serial Command 9912 Serial Command 9915 Serial Command 9914 VALIDATE THE VALUES Serial Command 9994 Validate 58 Enter Setup Appendix II KEYBOARD WEDGE TABLE & ASCII TABLE KEYBOARD WEDGE TABLE F2 SP INS F3 DLT F4 Home F5 End F6 Up F7 Down F8 Left F9 BS F10 HT F11 LF F12 Right ESC PgUp Exec CR CR* PgDn F1 Dly ENTER* Note: (1) b~k: Digits of numeric keypad. (2) CR*/Send/ENTER*: ENTER key on the numeric keypad. KEY TYPE Serial Command 9936 Serial Command 9926 Scan Code Note: If "Keyboard Wedge" is configured for interface, Key Type and Key Status will then become applicable. 59 Scanner Configuration SmartScan Manual KEY STATUS Serial Command 9931 Serial Command 9930 Add Shift Add Left Ctrl Serial Command 9933 Serial Command 9932 Add Left Alt Add Right Ctrl Serial Command 9934 Add Right Alt Note: Decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. ASCII TABLE DLE SP SOH DC1 STX DC2 ETX DC3 EOT DC4 ENQ NAK ACK SYN BEL ETB BS CAN HT EM LF SUB VT ESC FF FS CR GS SO RS SI US DEL 60 Appendix III HOST SERIAL COMMANDS SERIAL COMMANDS #@nnnn Purpose To configure the scanner. Remarks nnnn – the four digits of command parameters. For example, “9952” is to list the current Code ID settings. “0x23” + “0x40” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d” #@ - - - - Purpose To halt the scanner. Remarks “0x23” + “0x40” + “0x2d” + “0x2d” + “0x2d” + “0x2d” + “0x0d” #@ . . . . Purpose To resume operation. Remarks “0x23” + “0x40” + “0x2e” + “0x2e” + “0x2e” + “0x2e” + “0x0d” #@//// Purpose To respond with a beep. Remarks “0x23” + “0x40” + “0x2f” + “0x2f” + “0x2f” + “0x2f” + “0x0d” EXAMPLE Send the serial commands via RS-232 interface or Bluetooth SPP. For example, run HyperTerminal on the host computer. For the scanner to change the buzzer frequency to 2 kHz and beep – #@0048 #@//// For the scanner to change the buzzer frequency to 8 kHz and beep – #@0046 #@//// 61 Scanner Configuration SmartScan Manual For the scanner to change the buzzer frequency to 4 kHz and beep – #@0047 #@//// For the scanner to change the buzzer frequency to 1 kHz and beep – #@0049 #@//// 62 Appendix IV UPGRADING FIRMWARE HOW TO UPGRADE 1166/1266 FIRMWARE You can only upgrade firmware of one scanner at a time. You must remove the battery of each of the rest scanners when there is more than one scanner connected to your computer, either via (1) the 3666 cradle or (2) the 3667 cradle or any generic Bluetooth dongle. Note: In case it fails downloading due to low battery, make sure the targe scanner is loaded with a fully charged battery. USING 3666 1) Connect the power supply cord from the 3666 cradle to a proper power outlet. 2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port. 3) Refer to section 1.5 for the target scanner to set connection with the 3666 cradle. Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds. Both labels can be located at the bottom of the cradle. 4) Read the following labels in sequence to configure the scanner to use RS-232 as output interface. Enter Setup Activate RS-232 Interface 115200 bps Update 5) Read the following labels in sequence for the scanner to enter the download mode. The scanner will respond with beeps to indicate it is ready for downloading. 63 Scanner Configuration SmartScan Manual Enter Setup Download 6) Run the download utility “ProLoad.exe” or “Download.exe” on your computer. (Download.exe requires version 2.3 or later!) Open the firmware update “1x66-xx.shx”, and select the correct COM port. Baud rate – 115,200 bps Data bit –8 Parity – None Flow control – None 7) The scanner will automatically restart itself when upgrading firmware is completed successfully. USING 3667 OR GENERIC DONGLE 1) Connect the 3667 cradle or any Bluetooth dongle to your computer via the USB port. 2) Refer to section 1.6.1 for the target scanner to establish a connection with your computer via the 3667 cradle or a dongle. Read the following labels in sequence to configure the scanner to use Bluetooth Serial Port as output interface. Enter Setup Activate Bluetooth SPP (and read labels for PIN code…) Update 3) Same as steps 5 ~ 7 above. 64 Appendix IV Upgrading Firmware HOW TO UPGRADE 3666 FIRMWARE 1) Connect the power supply cord from the 3666 cradle to a proper power outlet. 2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port. 3) Refer to section 1.5 for a scanner to set connection with the 3666 cradle. Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds. Both labels can be located at the bottom of the cradle. 4) Read the following labels in sequence for the 3666 cradle to enter the download mode. The LED of the cradle will be flashing red and green to indicate it is ready for downloading. Enter Setup 3666 Download 5) Run the download utility “ProgLoad.exe” or “Download.exe” on your computer. (Download.exe requires version 2.3 or later!) Open the firmware update “3666*.shx”, and select the correct COM port. Baud rate – 38,400 bps Data bit –8 Parity – None Flow control – None 6) The 3666 cradle will automatically restart itself when upgrading firmware is completed successfully. 7) Read the “Update” label for the scanner to resume its operation (exit the configuration mode). Update FIND OUT FIRMWARE VERSION OF 3666 1) Connect the power supply cord from the 3666 cradle to a proper power outlet. 2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port. 3) Refer to section 1.5 for a scanner to set connection with the 3666 cradle. Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds. Both labels can be located at the bottom of the cradle. 65 Scanner Configuration SmartScan Manual 4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in sequence for the scanner to get the firmware version of the 3666 cradle. If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead. Enter Setup Version 5) The current version information of the 3666 cradle will be displayed. For example, Version = V1.06 Oct 01 2003 SN: SW3000014 6) Read the “Update” label for the scanner to resume its operation (exit the configuration mode). Update 66 Scanner Configuration SmartScan Manual 4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in sequence for the scanner to get the firmware version of the 3666 cradle. If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead. Enter Setup Version 5) The current version information of the 3666 cradle will be displayed. For example, Version = V1.06 Oct 01 2003 SN: SW3000014 6) Read the “Update” label for the scanner to resume its operation (exit the configuration mode). Update 66
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Company : CipherLab Co., Ltd. Comments : Copyright © CipherLab Co., Ltd., all rights reserved. Create Date : 2008:12:05 11:36:33+08:00 Modify Date : 2008:12:05 11:36:33+08:00 Metadata Date : 2008:12:05 11:35:36+08:00 Creator Tool : PScript5.dll Version 5.2 Document ID : uuid:71EC70C77DC2DD1192048E6CD240990E Instance ID : uuid:d7d4f227-4947-4248-a307-d38531327840 Derived From Instance ID : uuid:096c2273-c10a-4b4d-b974-d26d8d4f8653 Derived From Document ID : uuid:959568222DBCDD119343ABFD3EE21626 Format : application/postscript Title : Scanner Configuration Creator : Carrie Chen Description : SmartScan Manual Page Count : 75 Subject : SmartScan Manual Author : Carrie ChenEXIF Metadata provided by EXIF.tools