CipherLab 36662 Cradle User Manual Scanner Configuration

CipherLab Co., Ltd. Cradle Scanner Configuration

User manual

Download: CipherLab 36662 Cradle User Manual Scanner Configuration
Mirror Download [FCC.gov]CipherLab 36662 Cradle User Manual Scanner Configuration
Document ID1040832
Application IDbwhvUjFYUZPK4kdpsk/5lA==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize44.57kB (557104 bits)
Date Submitted2008-12-08 00:00:00
Date Available2008-12-08 00:00:00
Creation Date2008-12-05 11:36:33
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2008-12-05 11:36:33
Document TitleScanner Configuration
Document CreatorPScript5.dll Version 5.2
Document Author: Carrie Chen

 ƒ‡”‘ˆ‹‰—”ƒ–‹‘
ƒ”– ƒƒ—ƒŽ
DOCVersion2.21
Thisdocumentisspecificallydesignedfortheusertoprinttwopagespersheetofpaperwithoptimal
printquality.
Copyright © 2005~ 2008 CIPHERLAB CO., LTD.
All rights reserved
The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a
license agreement containing restrictions on use and disclosure and is also protected by copyright
law. Reverse engineering of the software is prohibited.
Due to continued product development this information may change without notice. The
information and intellectual property contained herein is confidential between CIPHERLAB and the
client and remains the exclusive property of CIPHERLAB CO., LTD. If you find any problems in the
documentation, please report them to us in writing. CIPHERLAB does not warrant that this
document is error-free.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any
form or by any means, electronic, mechanical, photocopying, recording or otherwise without the
prior written permission of CIPHERLAB CO., LTD.
For product consultancy and technical support, please contact your local sales representative. Also,
you may visit our web site for more information.
The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD.
Microsoft, Windows, and the Windows logo are registered trademarks of Microsoft Corporation in
the United States and/or other countries.
Bluetooth is a trademark of Bluetooth SIG, Inc., U.S.A.
Other product names mentioned in this manual may be trademarks or registered trademarks of their
respective companies and are hereby acknowledged.
The editorial use of these names is for identification as well as to the benefit of the owners, with no
intention of infringement.
CIPHERLAB CO., LTD.
Website: http://www.cipherlab.com
RELEASE NOTES
VERSION
DATE
NOTES
2.21
Jan. 02, 2008
Larger setup barcodes
2.20
Nov. 30, 2007
New Word template applied
2.15
Nov.13, 2006
2.14~
Nov. 06, 2006
 New: Bluetooth HID supports Japanese keyboard.
2.12
Mar. 03, 2006
2.11
Jan.27, 2006
 Modified: Typo errors corrected.
2.10
Jan.18, 2006
 Modified: Bluetooth HID doesn’t support the following functions on
New: 3667 Bluetooth Cradle for 1166/1266
Modified: Auto-Sense mode supported on 1100 only.
New: Appendix III – Host Serial Commands
New: Appendix IV – Upgrading Firmware
Modified: Add notice for BT SPP and HID power saving – Please
disable power saving when connecting more than two 1x66
scanners to Bluetooth dongle.
PDAs running Windows CE – Capital Lock Setting: Auto Detection,
Digit Transmission: Numeric Key, and Alt Composing.
 Modified: The default Capital Lock setting of Bluetooth HID is
changed from “Auto Detection” to “Capital Lock Off”.
2.00
Dec. 30, 2005
 New: Firmware version V4.20
 New: Bluetooth HID supported
 New: Firmware version V4.10
1.00
Oct. 31, 2005
First release
CONTENTS
RELEASE NOTES .................................................................................................................................. 3
OVERVIEW............................................................................................................................................ 1
Enter Configuration Mode................................................................................................................. 1
Exit Configuration Mode.................................................................................................................... 1
Update Settings............................................................................................................................ 1
Exit without Changes.................................................................................................................... 1
Restore Defaults................................................................................................................................ 1
List Current Settings.......................................................................................................................... 2
BLUETOOTH SETTINGS (1166/1266)................................................................................................. 3
1.1 RF Auto Shutdown (Suspend mode) ......................................................................................... 3
1.2 Power Saving (Sniff Mode) ......................................................................................................... 3
1.3 Transmit Buffer Setting .............................................................................................................. 3
1.4 Memory Mode ............................................................................................................................. 3
1.4.1 Memory Mode .................................................................................................................... 3
1.4.2 Send Data........................................................................................................................... 4
1.4.3 Clear Data........................................................................................................................... 4
1.4.4 Memory Data Delay............................................................................................................ 4
1.5 Set Connection with 3666 ......................................................................................................... 5
1.6 Set Connection with 3667 or Generic Dongle .......................................................................... 5
1.6.1 Bluetooth Serial Port Parameters ..................................................................................... 5
1.6.2 Bluetooth HID Parameters................................................................................................. 6
READER SETTINGS .............................................................................................................................. 9
2.1 Good Read Notification .............................................................................................................. 9
2.1.1 Buzzer Setting .................................................................................................................... 9
2.1.2 Buzzer Frequency............................................................................................................... 9
2.2 Read Redundancy ...................................................................................................................... 9
2.3 Scan Mode .................................................................................................................................. 9
2.4 Auto-Sense Mode (1100 only) .................................................................................................10
2.5 Scanner Time-Out .....................................................................................................................10
2.6 Delay between Re-read ............................................................................................................ 10
2.7 Negative Barcode Setting ........................................................................................................11
OUTPUT INTERFACES......................................................................................................................... 13
3.1 Keyboard Wedge Parameters ..................................................................................................13
3.1.1 Activate and Select Keyboard Type.................................................................................13
3.1.2 Alphabets Layout.............................................................................................................. 14
3.1.3 Digits Layout .....................................................................................................................14
3.1.4 Capital Lock Type ............................................................................................................. 14
3.1.5 Capital Lock Setting .........................................................................................................14
3.1.6 Alphabets Transmission ..................................................................................................15
Scanner Configuration SmartScan Manual
3.1.7 Digits Transmission..........................................................................................................15
3.1.8 ALT Composing................................................................................................................. 15
3.1.9 Inter-Character Delay .......................................................................................................15
3.1.10 Laptop Support ..............................................................................................................15
3.2 RS-232 Parameters..................................................................................................................16
3.2.1 Activate RS-232 Interface ............................................................................................... 16
3.2.2 Baud Rate.........................................................................................................................16
3.2.3 Parity ................................................................................................................................. 16
3.2.4 Data Bits ........................................................................................................................... 17
3.2.5 Flow Control......................................................................................................................17
3.2.6 Inter-Character Delay .......................................................................................................17
3.3 WAND Emulation Parameters (1090+/1100/1105/1200) ................................................. 18
3.3.1 Activate Wand Emulation.................................................................................................18
3.3.2 Normal State ....................................................................................................................18
3.3.3 Bar State........................................................................................................................... 18
3.3.4 Module Time.....................................................................................................................18
3.3.5 Margin Time......................................................................................................................19
SYMBOLOGY SETTINGS..................................................................................................................... 21
4.1 Select Readable Barcodes.......................................................................................................21
4.2 Codabar Parameters ................................................................................................................ 25
4.3 Code 25 Parameters ................................................................................................................ 26
4.3.1 Industrial 25 ..................................................................................................................... 26
4.3.2 Interleaved 25 ..................................................................................................................27
4.3.3 Matrix 25 .......................................................................................................................... 28
4.4 Code 39 Parameters ................................................................................................................ 30
4.5 Code 93 Parameters ................................................................................................................ 30
4.6 Code 128 Parameters..............................................................................................................30
4.7 EAN-8 Parameters ....................................................................................................................31
4.8 EAN-13 Parameters..................................................................................................................32
4.9 EAN-128 Parameters................................................................................................................ 33
4.10 MSI Parameters...................................................................................................................... 34
4.11 Pharmacode Parameters.......................................................................................................36
4.11.1 French Pharmacode ......................................................................................................36
4.11.2 Italian Pharmacode .......................................................................................................36
4.12 Plessey Parameters ............................................................................................................... 37
4.13 RSS Family Parameters ......................................................................................................... 38
4.13.1 RSS-14............................................................................................................................ 38
4.13.2 RSS Limited....................................................................................................................38
4.13.3 RSS Expanded................................................................................................................39
4.14 Telepen Parameters...............................................................................................................40
4.15 UPC-A Parameters ..................................................................................................................41
4.16 UPC-E Parameters .................................................................................................................. 42
DATA OUTPUT FORMAT...................................................................................................................... 43
5.1 Character Substitution .............................................................................................................43
5.2 Prefix/Suffix Setting..................................................................................................................43
Scanner Configuration SmartScan Manual
5.3 Code ID Setting ......................................................................................................................... 43
5.3.1 Clear Code ID Settings .....................................................................................................43
5.3.2 Select Pre-defined Code ID..............................................................................................44
5.3.3 Change Code ID................................................................................................................ 44
5.4 Length Code Setting ................................................................................................................. 45
DATA EDITING .................................................................................................................................... 49
6.1 Format Selection ...................................................................................................................... 49
6.1.1 Activate Editing Formats..................................................................................................49
6.1.2 Exclusive Data Editing......................................................................................................49
6.2 Editing Format Parameters ...................................................................................................... 50
6.2.1 Select Format to Configure..............................................................................................50
6.2.2 Restore Default Format ................................................................................................... 50
6.2.3 Define Data Criteria .........................................................................................................50
6.2.4 Divide Data into Fields.....................................................................................................52
6.2.5 Additional Fields............................................................................................................... 55
6.2.6 Field Transmission Sequence .........................................................................................56
NUMERAL SYSTEMS.......................................................................................................................... 57
Decimal System............................................................................................................................... 57
Hexadecimal System....................................................................................................................... 58
KEYBOARD WEDGE TABLE & ASCII TABLE........................................................................................ 59
Keyboard Wedge Table ...................................................................................................................59
Key Type......................................................................................................................................59
Key Status .................................................................................................................................. 60
ASCII Table....................................................................................................................................... 60
HOST SERIAL COMMANDS ................................................................................................................ 61
Serial Commands ............................................................................................................................ 61
Example ...........................................................................................................................................61
UPGRADING FIRMWARE .................................................................................................................... 63
How to Upgrade 1166/1266 Firmware.........................................................................................63
Using 3666 ................................................................................................................................. 63
Using 3667 or Generic Dongle..................................................................................................64
How to Upgrade 3666 Firmware ....................................................................................................65
Find out Firmware Version of 3666 ..........................................................................................65
OVERVIEW
ENTER CONFIGURATION MODE
Serial Command
N/A
Enter Setup
EXIT CONFIGURATION MODE
UPDATE SETTINGS
Serial Command
9999
Update
EXIT WITHOUT CHANGES
Serial Command
9998
Abort
RESTORE DEFAULTS
Serial Command
9993
Restore Defaults
Note: The default value (if there is) for each setting is included in a pair of angle brackets “<>”.
Update
Scanner Configuration SmartScan Manual
LIST CURRENT SETTINGS
Serial Command
9950
List settings regarding Interface, Buzzer, and
Scanner Parameters
Page 1
Serial Command
9951
List settings regarding Prefix, Postfix, and
Length Code Setting
Page 2
Serial Command
9952
List settings regarding Code ID
Page 3
Serial Command
9953
List settings regarding: Readable Symbologies
Page 4
Serial Command
9954
List settings regarding Symbology Parameters
(1/3)
Page 5
Serial Command
9955
List settings regarding Symbology Parameters
(2/3)
Page 6
Serial Command
9956
List settings regarding Symbology Parameters
(3/3)
Page 7
Serial Command
9957
List settings regarding Editing Format 1
Page 8
Serial Command
9958
List settings regarding Editing Format 2
Page 9
Serial Command
9959
List settings regarding Editing Format 3
Page 10
Enter Setup
Chapter 1
BLUETOOTH SETTINGS (1166/1266)
1.1 RF AUTO SHUTDOWN (SUSPEND MODE)
1) Read this label to specify the time interval before the scanner enters suspend mode.
2) Read the “Decimal Value” label on page 57. For example, read “1” and “5” for the scanner to
suspend the connection with 3666 after being idle for 15 minutes.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0445
RF Auto Shutdown
after … minutes
1.2 POWER SAVING (SNIFF MODE)
Serial Command
0459
Serial Command
0458

Disable
1.3 TRANSMIT BUFFER SETTING
Serial Command
0386
Serial Command
0387
Enable

1.4 MEMORY MODE
1.4.1 MEMORY MODE
Serial Command
0321
Serial Command
0320
Enable

Update
Scanner Configuration SmartScan Manual
1.4.2 SEND DATA
Serial Command
9918
Send Data
1.4.3 CLEAR DATA
1) Read the “Clear Data” label to clear the flash memory.
2) Read the “Confirm” label to confirm the action.
Serial Command
9916
Serial Command
9917
Clear Data
Confirm
1.4.4 MEMORY DATA DELAY
Serial Command
0323
Serial Command
0322

250 ms
Serial Command
0325
Serial Command
0324
500 ms
Serial Command
0326
1 sec
Serial Command
0327
2 sec
3 sec
Serial Command
0329
Serial Command
0328
5 sec
8 sec
Enter Setup
Chapter 1 Bluetooth Settings (1166/1266)
1.5 SET CONNECTION WITH 3666
1) Read this label or the same one at the bottom of the 3666 cradle.
2) Read the “Serial Number” label at the bottom of the cradle within 5 seconds.
3) Proceed to select a desired output interface.
Serial Command
Set Connection
1.6 SET CONNECTION WITH 3667 OR GENERIC DONGLE
1.6.1 BLUETOOTH SERIAL PORT PARAMETERS
Serial Command
0453
Activate Bluetooth SPP
DEVICE NAME BROADCASTING
Serial Command
0451
Serial Command
0450

No
AUTHENTICATION
Serial Command
0448
Serial Command
0449
Yes

PIN CODE
1) Read this label to specify the PIN code.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string (max. 6
characters are allowed).
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0452
Enter PIN Code …
Update
Scanner Configuration SmartScan Manual
1.6.2 BLUETOOTH HID PARAMETERS
1) Read this label to activate Bluetooth HID and select a keyboard type.
2) Read the “Decimal Value” label on page 57. Refer to the table below for the number of desired
keyboard type.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0000
Activate & Select
Keyboard Type …
NO.
KEYBOARD TYPE
NO.
KEYBOARD TYPE
64
PCAT (US)
70
PCAT (UK)
65
PCAT (French)
71
PCAT (Belgium)
66
PCAT (German)
72
PCAT (Spanish)
67
PCAT (Italian)
73
PCAT (Portuguese)
68
PCAT (Swedish)
74
PS55 A01-2 (Japanese)
69
PCAT (Norwegian)
RESET CONNECTION
Read this label when switching connection from one PC to another and re-connection is required.
Serial Command
9972
Reset Connection
DEVICE NAME BROADCASTING
Serial Command
0451
Serial Command
0450

No
AUTHENTICATION
Serial Command
0449
Serial Command
0448
Yes

Enter Setup
Chapter 1 Bluetooth Settings (1166/1266)
PIN CODE
1) Read this label to specify the PIN code.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string (max. 6
characters are allowed).
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0452
Enter PIN Code …
ALPHABETS LAYOUT
Serial Command
0313
Serial Command
0312

AZERTY
Serial Command
0314
QWERTZ
DIGITS LAYOUT
Serial Command
0008
Serial Command
0007

Upper Row
Serial Command
0009
Lower Row
CAPITAL LOCK TYPE
Serial Command
0011
Serial Command
0010

Shift Lock
Serial Command
0012
Capital Lock
Update
Scanner Configuration SmartScan Manual
CAPITAL LOCK SETTING
Serial Command
0003
Serial Command
0002
Auto Detection
Capital Lock ON
Serial Command
0004

ALPHABETS TRANSMISSION
Serial Command
0006
Serial Command
0005
Ignore Case

DIGITS TRANSMISSION
Serial Command
0014
Serial Command
0013
Numeric Key

ALT COMPOSING
Serial Command
0334
Serial Command
0335
Yes

Enter Setup
Chapter 2
READER SETTINGS
2.1 GOOD READ NOTIFICATION
2.1.1 BUZZER SETTING
Serial Command
0319
Serial Command
0318

Disable Buzzer
2.1.2 BUZZER FREQUENCY
Serial Command
0047
Serial Command
0046
8 kHz
<4 kHz>
Serial Command
0049
Serial Command
0048
2 kHz
1 kHz
2.2 READ REDUNDANCY
Serial Command
0202
Serial Command
0201

Serial Command
0203
One Time
Serial Command
0204
Two Times
Three Times
2.3 SCAN MODE
Serial Command
0067
Serial Command
0066

Continuous Mode
(Default for 1000/1090+)
Update
Scanner Configuration SmartScan Manual
Serial Command
0069
Serial Command
0068
Auto Power Off Mode
Serial Command
0070
Alternate Mode
Serial Command
0071
Momentary Mode
Repeat Mode
Serial Command
0073
Serial Command
0072

Test Mode
(Default for
1100/1105/1166/1200/1266)
2.4 AUTO-SENSE MODE (1100 ONLY)
Serial Command
0333
Serial Command
0332
Enable

2.5 SCANNER TIME-OUT
1) Read this label to specify the time interval before the scan engine times out in Laser, Auto Off, or
Auto Power Off mode.
2) Read the “Decimal Value” label on page 57. For example, read “1” and “0” for the scanner to
automatically shut down after being idle for 10 seconds.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0207
Scanner Time-Out
after … seconds
2.6 DELAY BETWEEN RE-READ
Serial Command
0337
Serial Command
0336
100 ms
200 ms
10
Enter Setup
Chapter 2 Reader Settings
Serial Command
0339
Serial Command
0338
<400 ms>
800 ms
Serial Command
0341
Serial Command
0340
1 sec
2 sec
Serial Command
0343
Serial Command
0342
3 sec
5 sec
2.7 NEGATIVE BARCODE SETTING
Serial Command
0200
Serial Command
0199
Enable

11
Update
Scanner Configuration SmartScan Manual
12
Enter Setup
Chapter 3
OUTPUT INTERFACES
3.1 KEYBOARD WEDGE PARAMETERS
3.1.1 ACTIVATE AND SELECT KEYBOARD TYPE
1) Read this label to activate Keyboard Wedge and select a keyboard type.
2) Read the “Decimal Value” label on page 57. Refer to the table below for the number of desired
keyboard type.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0000
Activate & Select
Keyboard Type …
NO.
KEYBOARD TYPE
NO.
KEYBOARD TYPE
PCAT (US)
15
PS55 001-81
PCAT (French)
16
PS55 001-2
PCAT (German)
17
PS55 001-82
PCAT (Italian)
18
PS55 001-3
PCAT (Swedish)
19
PS55 001-8A
PCAT (Norwegian)
20
PS55 002-1, 003-1
PCAT (UK)
21
PS55 002-81, 003-81
PCAT (Belgium)
22
PS55 002-2, 003-2
PCAT (Spanish)
23
PS55 002-82, 003-82
10
PCAT (Portuguese)
24
PS55 002-3, 003-3
11
PS55 A01-1
25
PS55 002-8A, 003-8A
12
PS55 A01-2 (Japanese)
26
IBM 3477 Type 4 (Japanese)
13
PS55 A01-3
27
PS2-30
14
PS55 001-1
28
IBM 34XX/319X, Memorex Telex 122 Keys
13
Update
Scanner Configuration SmartScan Manual
3.1.2 ALPHABETS LAYOUT
Serial Command
0313
Serial Command
0312

AZERTY
Serial Command
0314
QWERTZ
3.1.3 DIGITS LAYOUT
Serial Command
0008
Serial Command
0007

Upper Row
Serial Command
0009
Lower Row
3.1.4 CAPITAL LOCK TYPE
Serial Command
0011
Serial Command
0010

Shift Lock
Serial Command
0012
Capital Lock
3.1.5 CAPITAL LOCK SETTING
Serial Command
0003
Serial Command
0002
Auto Detection
Capital Lock ON
Serial Command
0004

14
Enter Setup
Chapter 3 Output Interfaces
3.1.6 ALPHABETS TRANSMISSION
Serial Command
0006
Serial Command
0005
Ignore Case

3.1.7 DIGITS TRANSMISSION
Serial Command
0014
Serial Command
0013
Numeric Key

3.1.8 ALT COMPOSING
Serial Command
0334
Serial Command
0335
Yes

3.1.9 INTER-CHARACTER DELAY
1) Read this label to specify the inter-character delay.
2) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0015
Inter-Character
Delay …
3.1.10 LAPTOP SUPPORT
Serial Command
0388
Serial Command
0389
Enable

15
Update
Scanner Configuration SmartScan Manual
3.2 RS-232 PARAMETERS
3.2.1 ACTIVATE RS-232 INTERFACE
Serial Command
0001
Activate RS-232
Interface
3.2.2 BAUD RATE
Serial Command
0016
Serial Command
0023
115200 bps
Serial Command
0017
38400 bps
Serial Command
0018
19200 bps
<9600 bps>
Serial Command
0020
Serial Command
0019
4800 bps
2400 bps
Serial Command
0022
Serial Command
0021
1200 bps
600 bps
(for 1200 only)
3.2.3 PARITY
Serial Command
0029
Serial Command
0028

Even
Serial Command
0030
Odd
16
Enter Setup
Chapter 3 Output Interfaces
3.2.4 DATA BITS
Serial Command
0035
Serial Command
0034
<8 bits>
7 bits
3.2.5 FLOW CONTROL
Serial Command
0043
Serial Command
0042

Scanner Ready
Serial Command
0045
Serial Command
0044
Data Ready
Invert Data Ready
3.2.6 INTER-CHARACTER DELAY
1) Read this label to specify the inter-character delay.
2) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0015
Inter-Character
Delay …
17
Update
Scanner Configuration SmartScan Manual
3.3 WAND EMULATION PARAMETERS (1090+/1100/1105/1200)
3.3.1 ACTIVATE WAND EMULATION
Serial Command
0306
Activate Wand
Emulation
3.3.2 NORMAL STATE
Serial Command
0303
Serial Command
0302
High

3.3.3 BAR STATE
Serial Command
0305
Serial Command
0304

Low
3.3.4 MODULE TIME
Serial Command
0363
Serial Command
0362
250 μs
Serial Command
0364
500 μs
Serial Command
0365
<1 ms>
1.5 ms
Serial Command
0367
Serial Command
0366
2 ms
3 ms
Serial Command
0369
Serial Command
0368
4 ms
5 ms
18
Enter Setup
Chapter 3 Output Interfaces
3.3.5 MARGIN TIME
Serial Command
0371
Serial Command
0370
5 ms
10 ms
Serial Command
0373
Serial Command
0372
<20 ms>
Serial Command
0374
30 ms
Serial Command
0375
40 ms
60 ms
Serial Command
0377
Serial Command
0376
80 ms
100 ms
19
Update
Scanner Configuration SmartScan Manual
20
Enter Setup
Chapter 4
SYMBOLOGY SETTINGS
4.1 SELECT READABLE BARCODES
CODABAR
Serial Command
0087
Serial Command
0086

Disable
CODE 39
Serial Command
0075
Serial Command
0074

Disable
CODE 93
Serial Command
0089
Serial Command
0088

Disable
CODE 128
Serial Command
0091
Serial Command
0090

Disable
EAN-128
Serial Command
0105
Serial Command
0104
Enable

EAN-13
Serial Command
0107
Serial Command
0106

Disable No Addon
21
Update
Scanner Configuration SmartScan Manual
Serial Command
0109
Serial Command
0108
Enable Addon 2
Serial Command
0110

Serial Command
0111
Enable Addon 5

EAN-8
Serial Command
0099
Serial Command
0098

Disable No Addon
Serial Command
0101
Serial Command
0100
Enable Addon 2
Serial Command
0102

Serial Command
0103
Enable Addon 5

FRENCH PHARMACODE
Serial Command
0079
Serial Command
0078
Enable

ITALIAN PHARMACODE
Serial Command
0077
Serial Command
0076
Enable

INDUSTRIAL 25
Serial Command
0081
Serial Command
0080

Disable
22
Enter Setup
Chapter 4 Symbology Settings
INTERLEAVED 25
Serial Command
0083
Serial Command
0082

Disable
MATRIX 25
Serial Command
0085
Serial Command
0084
Enable

MSI
Serial Command
0113
Serial Command
0112
Enable

PLESSEY
Serial Command
0115
Serial Command
0114
Enable

RSS-14 & EXPANDED
Serial Command
413
Serial Command
0412
Enable RSS-14 & RSS
Expanded

RSS LIMITED
Serial Command
0415
Serial Command
0414
Enable

TELEPEN
Serial Command
0437
Serial Command
0436
Enable

23
Update
Scanner Configuration SmartScan Manual
UPC-A
Serial Command
0292
Serial Command
0291

Serial Command
0293
Disable No Addon
Serial Command
0294
Enable Addon 2

Serial Command
0296
Serial Command
0295
Enable Addon 5

UPC-E
Serial Command
0093
Serial Command
0092

Serial Command
0094
Disable No Addon
Serial Command
0095
Enable Addon 2

Serial Command
0097
Serial Command
0096
Enable Addon 5

24
Enter Setup
Chapter 4 Symbology Settings
4.2 CODABAR PARAMETERS
Serial Command
0087
Serial Command
0086

Disable
START / STOP CHARACTERS SELECTION
Serial Command
0152
Serial Command
0151

abcd/tn*e
Serial Command
0154
Serial Command
0153
ABCD/ABCD
ABCD/TN*E
START / STOP TRANSMISSION
Serial Command
0156
Serial Command
0155
Enable

CLSI CONVERSION
Serial Command
0158
Serial Command
0157
Enable

25
Update
Scanner Configuration SmartScan Manual
4.3 CODE 25 PARAMETERS
4.3.1 INDUSTRIAL 25
Serial Command
0081
Serial Command
0080

Disable
START / STOP PATTERN SELECTION
Serial Command
0131
Serial Command
0130

Interleaved 25
Serial Command
0132
Matrix 25
CHECKSUM VERIFICATION
Serial Command
0140
Serial Command
0139
Enable

CHECKSUM TRANSMISSION
Serial Command
0142
Serial Command
0141

Disable
CODE LENGTH QUALIFICATION
1) Read the label to enable either Max. /Min. length qualification or fixed length qualification.
2) Read the labels for Max. /Min or fixed length separately.
3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).
4) Read the “Validate” label on the same page to complete this setting.
Serial Command
0208
Enable Max./Min. Length …
26
Enter Setup
Chapter 4 Symbology Settings
Serial Command
0211
Serial Command
0210
Max. Length
Min. Length
Serial Command
0209
Serial Command
0210
Enable Fixed Length …
Serial Command
0211
Fixed Length 1
Fixed Length 2
4.3.2 INTERLEAVED 25
Serial Command
0083
Serial Command
0082

Disable
START / STOP PATTERN SELECTION
Serial Command
0134
Serial Command
0133
Industrial 25

Serial Command
0135
Matrix 25
CHECKSUM VERIFICATION
Serial Command
0144
Serial Command
0143
Enable

CHECKSUM TRANSMISSION
Serial Command
0146
Serial Command
0145

Disable
27
Update
Scanner Configuration SmartScan Manual
CODE LENGTH QUALIFICATION
1) Read the label to enable either Max. /Min. length qualification or fixed length qualification.
2) Read the labels for Max. /Min or fixed length separately.
3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).
4) Read the “Validate” label on the same page to complete this setting.
Serial Command
0212
Serial Command
0214
Enable Max./Min. Length …
Serial Command
0215
Max. Length
Min. Length
Serial Command
0213
Serial Command
0214
Enable Fixed Length …
Serial Command
0215
Fixed Length 1
Fixed Length 2
4.3.3 MATRIX 25
Serial Command
0085
Serial Command
0084
Enable

START / STOP PATTERN SELECTION
Serial Command
0137
Serial Command
0136
Industrial 25
Interleaved 25
Serial Command
0138

28
Enter Setup
Chapter 4 Symbology Settings
CHECKSUM VERIFICATION
Serial Command
0148
Serial Command
0147
Enable

CHECKSUM TRANSMISSION
Serial Command
0150
Serial Command
0149

Disable
CODE LENGTH QUALIFICATION
1) Read the label to enable either Max. /Min. length qualification or fixed length qualification.
2) Read the labels for Max. /Min or fixed length separately.
3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).
4) Read the “Validate” label on the same page to complete this setting.
Serial Command
0216
Serial Command
0218
Enable Max./Min. Length …
Serial Command
0219
Max. Length
Min. Length
Serial Command
0217
Serial Command
0218
Enable Fixed Length …
Serial Command
0219
Fixed Length 1
Fixed Length 2
29
Update
Scanner Configuration SmartScan Manual
4.4 CODE 39 PARAMETERS
Serial Command
0075
Serial Command
0074

Disable
START / STOP TRANSMISSION
Serial Command
0117
Serial Command
0116
Enable

CHECKSUM VERIFICATION
Serial Command
0119
Serial Command
0118
Enable

CHECKSUM TRANSMISSION
Serial Command
0121
Serial Command
0120

Disable
STANDARD / FULL ASCII CODE 39
Serial Command
0123
Serial Command
0122
Full ASCII

4.5 CODE 93 PARAMETERS
Serial Command
0089
Serial Command
0088

Disable
4.6 CODE 128 PARAMETERS
Serial Command
0091
Serial Command
0090

Disable
30
Enter Setup
Chapter 4 Symbology Settings
4.7 EAN-8 PARAMETERS
Serial Command
0099
Serial Command
0098

Serial Command
0100
Disable No Addon
Serial Command
0101
Enable Addon 2

Serial Command
0103
Serial Command
0102
Enable Addon 5

CONVERT TO EAN-13
Serial Command
0196
Serial Command
0195
Enable

CHECKSUM TRANSMISSION
Serial Command
0188
Serial Command
0187

Disable
31
Update
Scanner Configuration SmartScan Manual
4.8 EAN-13 PARAMETERS
Serial Command
0107
Serial Command
0106

Serial Command
0108
Disable No Addon
Serial Command
0109
Enable Addon 2

Serial Command
0111
Serial Command
0110
Enable Addon 5

ISBN CONVERSION
Serial Command
0180
Serial Command
0179
Enable

ISSN CONVERSION
Serial Command
0181
Serial Command
0182
Enable

CHECKSUM TRANSMISSION
Serial Command
0190
Serial Command
0189

Disable
32
Enter Setup
Chapter 4 Symbology Settings
4.9 EAN-128 PARAMETERS
Serial Command
0105
Serial Command
0104
Enable

CODE ID TRANSMISSION
Serial Command
0435
Serial Command
0434
Enable

FIELD SEPARATOR
Serial Command
0301
Enable Field Separator …
1) Read this label to enable field separator.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
33
Update
Scanner Configuration SmartScan Manual
4.10 MSI PARAMETERS
Serial Command
0113
Serial Command
0112
Enable

CHECKSUM VERIFICATION
Serial Command
0168
Serial Command
0167

Double Modulo 10
Serial Command
0169
Modulo 10 & 11
CHECKSUM TRANSMISSION
Serial Command
0171
Serial Command
0170

Both Digits
Transmitted
Serial Command
0172
Both Digits Not
Transmitted
CODE LENGTH QUALIFICATION
1) Read the label to enable either Max. /Min. length qualification or fixed length qualification.
2) Read the labels for Max. /Min or fixed length separately.
3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).
4) Read the “Validate” label on the same page to complete this setting.
Serial Command
0220
Enable Max./Min. Length …
34
Enter Setup
Chapter 4 Symbology Settings
Serial Command
0223
Serial Command
0222
Max. Length
Min. Length
Serial Command
0221
Serial Command
0222
Enable Fixed Length …
Serial Command
0223
Fixed Length 1
Fixed Length 2
35
Update
Scanner Configuration SmartScan Manual
4.11 PHARMACODE PARAMETERS
4.11.1 FRENCH PHARMACODE
Serial Command
0079
Serial Command
0078
Enable

CHECKSUM TRANSMISSION
Serial Command
0129
Serial Command
0128

Disable
4.11.2 ITALIAN PHARMACODE
Serial Command
0077
Serial Command
0076
Enable

CHECKSUM TRANSMISSION
Serial Command
0127
Serial Command
0126

Disable
36
Enter Setup
Chapter 4 Symbology Settings
4.12 PLESSEY PARAMETERS
Serial Command
0115
Serial Command
0114
Enable

CONVERT TO UK PLESSEY
Serial Command
0166
Serial Command
0165
Enable

CHECKSUM TRANSMISSION
Serial Command
0164
Serial Command
0163

Disable
37
Update
Scanner Configuration SmartScan Manual
4.13 RSS FAMILY PARAMETERS
CODE ID SELECTION
Serial Command
0433
Serial Command
0432
]C1
<]e0>
4.13.1 RSS-14
Serial Command
413
Serial Command
0412
Enable RSS-14 & RSS
Expanded

CODE ID TRANSMISSION
Serial Command
0419
Serial Command
0418

Disable
APPLICATION ID TRANSMISSION
Serial Command
0425
Serial Command
0424

Disable
CHECKSUM TRANSMISSION
Serial Command
0429
Serial Command
0428

Disable
4.13.2 RSS LIMITED
Serial Command
0415
Serial Command
0414
Enable

38
Enter Setup
Chapter 4 Symbology Settings
CODE ID TRANSMISSION
Serial Command
0421
Serial Command
0420

Disable
APPLICATION ID TRANSMISSION
Serial Command
0427
Serial Command
0426

Disable
CHECKSUM TRANSMISSION
Serial Command
0431
Serial Command
0430

Disable
4.13.3 RSS EXPANDED
Serial Command
413
Serial Command
0412
Enable RSS-14 & RSS
Expanded

CODE ID TRANSMISSION
Serial Command
0423
Serial Command
0422

Disable
39
Update
Scanner Configuration SmartScan Manual
4.14 TELEPEN PARAMETERS
Serial Command
0437
Serial Command
0436
Enable

TELEPEN OUTPUT
Serial Command
0441
Serial Command
0440
Original Telepen
(Numeric)

APPLY ALL 3 EDITING FORMATS
Serial Command
0443
Serial Command
0444

Disable All
40
Enter Setup
Chapter 4 Symbology Settings
4.15 UPC-A PARAMETERS
Serial Command
0292
Serial Command
0291

Serial Command
0293
Disable No Addon
Serial Command
0294
Enable Addon 2

Serial Command
0296
Serial Command
0295
Enable Addon 5

CONVERT TO EAN-13
Serial Command
0177
Serial Command
0178

Disable
SYSTEM NUMBER TRANSMISSION
Serial Command
0193
Serial Command
0194

Disable
CHECKSUM TRANSMISSION
Serial Command
0185
Serial Command
0186

Disable
41
Update
Scanner Configuration SmartScan Manual
4.16 UPC-E PARAMETERS
Serial Command
0093
Serial Command
0092

Serial Command
0094
Disable No Addon
Serial Command
0095
Enable Addon 2

Serial Command
0097
Serial Command
0096
Enable Addon 5

SYSTEM NUMBER SELECTION
Serial Command
0287
Serial Command
0288

System Number 0 & 1
CONVERT TO UPC-A
Serial Command
0175
Serial Command
0176
Enable

SYSTEM NUMBER TRANSMISSION
Serial Command
0191
Serial Command
0192
Enable

CHECKSUM TRANSMISSION
Serial Command
0183
Serial Command
0184

Disable
42
Enter Setup
Chapter 5
DATA OUTPUT FORMAT
5.1 CHARACTER SUBSTITUTION
1) Read the label to enable either character substitution by set.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example,
read “3”, “0”, “2” and “D” for the scanner to replace the character [0] with a dash [-].
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0310
Serial Command
0309
Set 1
Set 2
Serial Command
0311
Set 3
5.2 PREFIX/SUFFIX SETTING
1) Read the label to apply prefix code or suffix code separately.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example,
read “2” and “B” for the scanner to prefix or suffix the character [+].
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0274
Serial Command
0273
Prefix Code
Suffix Code
5.3 CODE ID SETTING
5.3.1 CLEAR CODE ID SETTINGS
Serial Command
9960
Clear All Code ID
Settings
43
Update
Scanner Configuration SmartScan Manual
5.3.2 SELECT PRE-DEFINED CODE ID
Serial Command
9962
Serial Command
9961
Code ID Set 1
Code ID Set 2
Serial Command
9964
Serial Command
9963
Code ID Set 3
Code ID Set 4
Serial Command
9965
Code ID Set 5
5.3.3 CHANGE CODE ID
1) Read the label of a specific symbology to change its code ID.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example,
read “4” and “4” for applying the character [D] for Code ID.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0256
Serial Command
0262
Codabar
Serial Command
0263
Code 39
Serial Command
0264
Code 93
Code 128
Serial Command
0267
Serial Command
0266
EAN-8
EAN-13
Serial Command
0257
Serial Command
0258
French Pharmacode
Serial Command
0259
Italian Pharmacode
Serial Command
0260
Industrial 25
Interleaved 25
44
Enter Setup
Chapter 5 Data Output Format
Serial Command
0268
Serial Command
0261
Matrix 25
Serial Command
0269
MSI
Serial Command
0442
Plessey
Telepen
Serial Command
0265
Serial Command
0270
UPC-A
UPC-E
5.4 LENGTH CODE SETTING
CODABAR
Serial Command
0237
Serial Command
0236
Enable Length Code

CODE 39
Serial Command
0225
Serial Command
0224
Enable Length Code

CODE 93
Serial Command
0239
Serial Command
0238
Enable Length Code

CODE 128
Serial Command
0241
Serial Command
0240
Enable Length Code

EAN-128 & RSS FAMILY
Serial Command
0300
Serial Command
0299
Enable Length Code

45
Update
Scanner Configuration SmartScan Manual
EAN-8
Serial Command
0245
Serial Command
0244
Enable Length Code

EAN-13
Serial Command
0247
Serial Command
0246
Enable Length Code

FRENCH PHARMACODE
Serial Command
0229
Serial Command
0228
Enable Length Code

ITALIAN PHARMACODE
Serial Command
0227
Serial Command
0226
Enable Length Code

INDUSTRIAL 25
Serial Command
0231
Serial Command
0230
Enable Length Code

INTERLEAVED 25
Serial Command
0233
Serial Command
0232
Enable Length Code

MATRIX 25
Serial Command
0235
Serial Command
0234
Enable Length Code

46
Enter Setup
Chapter 5 Data Output Format
MSI
Serial Command
0249
Serial Command
0248
Enable Length Code

PLESSEY
Serial Command
0251
Serial Command
0250
Enable Length Code

TELEPEN
Serial Command
0439
Serial Command
0438
Enable Length Code

UPC-A
Serial Command
0290
Serial Command
0289
Enable Length Code

UPC-E
Serial Command
0243
Serial Command
0242
Enable Length Code

47
Update
Scanner Configuration SmartScan Manual
48
Enter Setup
Chapter 6
DATA EDITING
6.1 FORMAT SELECTION
6.1.1 ACTIVATE EDITING FORMATS
FORMAT 1
Serial Command
0282
Serial Command
0281
Enable Editing Format 1

FORMAT 2
Serial Command
0284
Serial Command
0283
Enable Editing Format 2

FORMAT 3
Serial Command
0286
Serial Command
0285
Enable Editing Format 3

APPLY ALL 3 EDITING FORMATS TO TELEPEN
Serial Command
0444
Serial Command
0443

Disable All
6.1.2 EXCLUSIVE DATA EDITING
Serial Command
0279
Serial Command
0280
Reject Non-conforming Data

49
Update
Scanner Configuration SmartScan Manual
6.2 EDITING FORMAT PARAMETERS
6.2.1 SELECT FORMAT TO CONFIGURE
START FORMAT PROGRAMMING
Serial Command
9982
Serial Command
9981
Configure Format 1
Configure Format 2
Serial Command
9983
Configure Format 3
END FORMAT PROGRAMMING
Serial Command
9980
End Format Programming
6.2.2 RESTORE DEFAULT FORMAT
Serial Command
9990
Restore Default Format
6.2.3 DEFINE DATA CRITERIA
APPLICABLE CODE TYPE
Serial Command
9991
Serial Command
9992

Serial Command
Serial Command
0500
0512
Codabar
Serial Command
0514
Clear All
Code 39
Serial Command
0516
Code 93
Code 128
50
End Format Programming
Chapter 6 Data Editing
Serial Command
0526
Serial Command
0524
EAN-8 No Addon
Serial Command
0528
EAN-8 Addon 2
Serial Command
0532
EAN-8 Addon 5
EAN-13 No Addon
Serial Command
0536
Serial Command
0534
EAN-13 Addon 2
EAN-13 Addon 5
Serial Command
0504
Serial Command
0590
EAN-128 / RSS
Serial Command
0502
French Pharmacode
Serial Command
0506
Italian Pharmacode
Industrial 25
Serial Command
0510
Serial Command
0508
Interleaved 25
Matrix 25
Serial Command
0540
Serial Command
0538
MSI
Serial Command
0584
Plessey
Serial Command
0586
UPC-A No Addon
UPC-A Addon 2
Serial Command
0518
Serial Command
0588
UPC-A Addon 5
UPC-E No Addon
Serial Command
0522
Serial Command
0520
UPC-E Addon 2
UPC-E Addon 5
DATA LENGTH
1) Read the labels for Max. /Min length separately.
51
Update
Scanner Configuration SmartScan Manual
2) Read the “Decimal Value” label on page 57 for the desired length.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0549
Serial Command
0548
Max. Length
Min. Length
MATCHING STRING
1) Read the label to specify a matching string.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0550
Matching String …
LOCATION OF MATCHING STRING
1) Read the label to specify the location of the matching string.
2) Read the “Decimal Value” label on page 57 for the desired location.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0551
Location of Matching String …
6.2.4 DIVIDE DATA INTO FIELDS
TOTAL NUMBER OF FIELDS
Serial Command
0579
Serial Command
0578

Two Fields
Serial Command
0581
Serial Command
0580
Three Fields
Serial Command
0582
Four Fields
Serial Command
0583
Five Fields
Six Fields
52
End Format Programming
Chapter 6 Data Editing
FIELD 1 SETTING
1) Read the label to divide field by a specified terminating string.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0555
Select Field Terminating String …
Serial Command
Serial Command
0553
0552
Include String
Discard String
1) Read the label to divide field by field length.
2) Read the “Decimal Value” label on page 57 for the desired field length.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0554
Divide Field by Field Length …
FIELD 2 SETTING
1) Read the label to divide field by a specified terminating string.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0559
Select Field Terminating String …
Serial Command
Serial Command
0557
0556
Include String
Discard String
1) Read the label to divide field by field length.
2) Read the “Decimal Value” label on page 57 for the desired field length.
3) Read the “Validate” label on the same page to complete this setting.
53
Update
Scanner Configuration SmartScan Manual
Serial Command
0558
Divide Field by Field Length …
FIELD 3 SETTING
1) Read the label to divide field by a specified terminating string.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0563
Select Field Terminating String …
Serial Command
Serial Command
0561
0560
Include String
Discard String
1) Read the label to divide field by field length.
2) Read the the “Decimal Value” label on page 57 for the desired field length.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0562
Divide Field by Field Length …
FIELD 4 SETTING
1) Read the label to divide field by a specified terminating string.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0567
Select Field Terminating String …
Serial Command
Serial Command
0565
0564
Include String
Discard String
1) Read the label to divide field by field length.
2) Read the “Decimal Value” label on page 57 for the desired field length.
54
End Format Programming
Chapter 6 Data Editing
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0566
Divide Field by Field Length …
FIELD 5 SETTING
1) Read the label to divide field by a specified terminating string.
2) Read the “Hexadecimal Value” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0571
Select Field Terminating String …
Serial Command
Serial Command
0569
0568
Include String
Discard String
1) Read the label to divide field by field length.
2) Read the “Decimal Value” label on page 57 for the desired field length.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0570
Divide Field by Field Length …
6.2.5 ADDITIONAL FIELDS
1) Read the label to specify an additional field, one at a time.
2) Read the “Hexadecimal Value” label on page 58 for the desired additional field.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
Serial Command
0572
0573
Additional Field 1…
Serial Command
0574
Additional Field 2…
Serial Command
0575
Additional Field 3…
Additional Field 4…
55
Update
Scanner Configuration SmartScan Manual
Serial Command
0576
Additional Field 5…
6.2.6 FIELD TRANSMISSION SEQUENCE
1) Read the “Start” label to begin with programming the field transmission sequence.
2) Program the transmission sequence by reading the desired fields as well as additional fields.
3) Read the “End” label on the same page to complete this setting.
Serial Command
0577
Start (Programming) …
Serial Command
9901
Serial Command
9902
Field 1
Field 2
Serial Command
9904
Serial Command
9903
Field 3
Field 4
Serial Command
9906
Serial Command
9905
Field 5
Field 6
Serial Command
9907
Serial Command
9908
Additional Field 1
Additional Field 2
Serial Command
9910
Additional Field 3
Additional Field 4
Serial Command
9909
Serial Command
9911
Additional Field 5
Serial Command
9994
End (Programming)
56
End Format Programming
Appendix I
NUMERAL SYSTEMS
DECIMAL SYSTEM
DECIMAL
Serial Command
9901
Serial Command
9900
Serial Command
9902
Serial Command
9903
Serial Command
9905
Serial Command
9904
Serial Command
9907
Serial Command
9906
Serial Command
9908
Serial Command
9909
VALIDATE THE VALUES
Serial Command
9994
Validate
57
Update
Scanner Configuration SmartScan Manual
HEXADECIMAL SYSTEM
HEXADECIMAL
Serial Command
9901
Serial Command
9900
Serial Command
9902
Serial Command
9903
Serial Command
9905
Serial Command
9904
Serial Command
9907
Serial Command
9906
Serial Command
9908
Serial Command
9909
Serial Command
9911
Serial Command
9910
Serial Command
9913
Serial Command
9912
Serial Command
9915
Serial Command
9914
VALIDATE THE VALUES
Serial Command
9994
Validate
58
Enter Setup
Appendix II
KEYBOARD WEDGE TABLE & ASCII TABLE
KEYBOARD WEDGE TABLE
F2
SP
INS
F3
DLT
F4
Home
F5
End
F6
Up
F7
Down
F8
Left
F9
BS
F10
HT
F11
LF
F12
Right
ESC
PgUp
Exec
CR
CR*
PgDn
F1
Dly
ENTER*
Note: (1) b~k: Digits of numeric keypad.
(2) CR*/Send/ENTER*: ENTER key on the numeric keypad.
KEY TYPE
Serial Command
9936
Serial Command
9926

Scan Code
Note: If "Keyboard Wedge" is configured for interface, Key Type and Key Status will then become
applicable.
59
Scanner Configuration SmartScan Manual
KEY STATUS
Serial Command
9931
Serial Command
9930
Add Shift
Add Left Ctrl
Serial Command
9933
Serial Command
9932
Add Left Alt
Add Right Ctrl
Serial Command
9934
Add Right Alt
Note: Decide whether or not to apply Key Status when “Normal Key” is selected for Key Type.
ASCII TABLE
DLE
SP
SOH
DC1
STX
DC2
ETX
DC3
EOT
DC4
ENQ
NAK
ACK
SYN
BEL
ETB
BS
CAN
HT
EM
LF
SUB
VT
ESC
FF
FS
CR
GS
SO
RS
SI
US
DEL
60
Appendix III
HOST SERIAL COMMANDS
SERIAL COMMANDS
#@nnnn
Purpose
To configure the scanner.
Remarks
nnnn – the four digits of command parameters. For example, “9952” is to list the
current Code ID settings.
“0x23” + “0x40” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d”
#@ - - - -
Purpose
To halt the scanner.
Remarks
“0x23” + “0x40” + “0x2d” + “0x2d” + “0x2d” + “0x2d” + “0x0d”
#@ . . . . 
Purpose
To resume operation.
Remarks
“0x23” + “0x40” + “0x2e” + “0x2e” + “0x2e” + “0x2e” + “0x0d”
#@////
Purpose
To respond with a beep.
Remarks
“0x23” + “0x40” + “0x2f” + “0x2f” + “0x2f” + “0x2f” + “0x0d”
EXAMPLE
Send the serial commands via RS-232 interface or Bluetooth SPP. For example, run HyperTerminal
on the host computer.
 For the scanner to change the buzzer frequency to 2 kHz and beep –
#@0048
#@////
 For the scanner to change the buzzer frequency to 8 kHz and beep –
#@0046
#@////
61
Scanner Configuration SmartScan Manual
 For the scanner to change the buzzer frequency to 4 kHz and beep –
#@0047
#@////
 For the scanner to change the buzzer frequency to 1 kHz and beep –
#@0049
#@////
62
Appendix IV
UPGRADING FIRMWARE
HOW TO UPGRADE 1166/1266 FIRMWARE
You can only upgrade firmware of one scanner at a time. You must remove the battery of each of
the rest scanners when there is more than one scanner connected to your computer, either via (1)
the 3666 cradle or (2) the 3667 cradle or any generic Bluetooth dongle.
Note: In case it fails downloading due to low battery, make sure the targe scanner is loaded with a
fully charged battery.
USING 3666
1) Connect the power supply cord from the 3666 cradle to a proper power outlet.
2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port.
3) Refer to section 1.5 for the target scanner to set connection with the 3666 cradle.
Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds.
Both labels can be located at the bottom of the cradle.
4) Read the following labels in sequence to configure the scanner to use RS-232 as output interface.
Enter Setup
Activate RS-232 Interface
115200 bps
Update
5) Read the following labels in sequence for the scanner to enter the download mode.
The scanner will respond with beeps to indicate it is ready for downloading.
63
Scanner Configuration SmartScan Manual
Enter Setup
Download
6) Run the download utility “ProLoad.exe” or “Download.exe” on your computer.
(Download.exe requires version 2.3 or later!)
Open the firmware update “1x66-xx.shx”, and select the correct COM port.
Baud rate
– 115,200 bps
Data bit
–8
Parity
– None
Flow control
– None
7) The scanner will automatically restart itself when upgrading firmware is completed successfully.
USING 3667 OR GENERIC DONGLE
1) Connect the 3667 cradle or any Bluetooth dongle to your computer via the USB port.
2) Refer to section 1.6.1 for the target scanner to establish a connection with your computer via
the 3667 cradle or a dongle.
Read the following labels in sequence to configure the scanner to use Bluetooth Serial Port as
output interface.
Enter Setup
Activate Bluetooth SPP (and read labels for PIN code…)
Update
3) Same as steps 5 ~ 7 above.
64
Appendix IV Upgrading Firmware
HOW TO UPGRADE 3666 FIRMWARE
1) Connect the power supply cord from the 3666 cradle to a proper power outlet.
2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port.
3) Refer to section 1.5 for a scanner to set connection with the 3666 cradle.
Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds.
Both labels can be located at the bottom of the cradle.
4) Read the following labels in sequence for the 3666 cradle to enter the download mode.
The LED of the cradle will be flashing red and green to indicate it is ready for downloading.
Enter Setup
3666 Download
5) Run the download utility “ProgLoad.exe” or “Download.exe” on your computer.
(Download.exe requires version 2.3 or later!)
Open the firmware update “3666*.shx”, and select the correct COM port.
Baud rate
– 38,400 bps
Data bit
–8
Parity
– None
Flow control
– None
6) The 3666 cradle will automatically restart itself when upgrading firmware is completed
successfully.
7) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).
Update
FIND OUT FIRMWARE VERSION OF 3666
1) Connect the power supply cord from the 3666 cradle to a proper power outlet.
2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port.
3) Refer to section 1.5 for a scanner to set connection with the 3666 cradle.
Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds.
Both labels can be located at the bottom of the cradle.
65
Scanner Configuration SmartScan Manual
4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in
sequence for the scanner to get the firmware version of the 3666 cradle.
If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead.
Enter Setup
Version
5) The current version information of the 3666 cradle will be displayed. For example,
Version = V1.06 Oct 01 2003
SN: SW3000014
6) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).
Update
66
Scanner Configuration SmartScan Manual
4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in
sequence for the scanner to get the firmware version of the 3666 cradle.
If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead.
Enter Setup
Version
5) The current version information of the 3666 cradle will be displayed. For example,
Version = V1.06 Oct 01 2003
SN: SW3000014
6) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).
Update
66

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Company                         : CipherLab Co., Ltd.
Comments                        : Copyright © CipherLab Co., Ltd., all rights reserved.
Create Date                     : 2008:12:05 11:36:33+08:00
Modify Date                     : 2008:12:05 11:36:33+08:00
Metadata Date                   : 2008:12:05 11:35:36+08:00
Creator Tool                    : PScript5.dll Version 5.2
Document ID                     : uuid:71EC70C77DC2DD1192048E6CD240990E
Instance ID                     : uuid:d7d4f227-4947-4248-a307-d38531327840
Derived From Instance ID        : uuid:096c2273-c10a-4b4d-b974-d26d8d4f8653
Derived From Document ID        : uuid:959568222DBCDD119343ABFD3EE21626
Format                          : application/postscript
Title                           : Scanner Configuration
Creator                         : Carrie Chen
Description                     : SmartScan Manual
Page Count                      : 75
Subject                         : SmartScan Manual
Author                          : Carrie Chen
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q3N-36662

Navigation menu