Cisco Systems 15454 Ftf2 Users Manual 454854r
15454-FTF2 to the manual b3d3bdd3-9a1d-4e7e-8c1f-f8ad1f905886
: Cisco-Systems Cisco-Systems-15454-Ftf2-Users-Manual-202053 cisco-systems-15454-ftf2-users-manual-202053 cisco-systems pdf
Open the PDF directly: View PDF .
Page Count: 828
Download | |
Open PDF In Browser | View PDF |
Cisco ONS 15454 Reference Manual Product and Documentation Release 8.5.x July 2010 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part Number: 78-18106-01 THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS. THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY. The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense. The following information is for FCC compliance of Class B devices: The equipment described in this manual generates and may radiate radio-frequency energy. If it is not installed in accordance with Cisco’s installation instructions, it may cause interference with radio and television reception. This equipment has been tested and found to comply with the limits for a Class B digital device in accordance with the specifications in part 15 of the FCC rules. These specifications are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. Modifying the equipment without Cisco’s written authorization may result in the equipment no longer complying with FCC requirements for Class A or Class B digital devices. In that event, your right to use the equipment may be limited by FCC regulations, and you may be required to correct any interference to radio or television communications at your own expense. You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures: • Turn the television or radio antenna until the interference stops. • Move the equipment to one side or the other of the television or radio. • Move the equipment farther away from the television or radio. • Plug the equipment into an outlet that is on a different circuit from the television or radio. (That is, make certain the equipment and the television or radio are on circuits controlled by different circuit breakers or fuses.) Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product. The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California. NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE. IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1005R) Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental. Cisco ONS 15454 Reference Manual, Release 8.5.x © 2007–2010 Cisco Systems, Inc. All rights reserved. C O N T E N T S About this Manual xli Revision History xli Document Objectives Audience xliv xlv Related Documentation xlv Document Conventions xlv Obtaining Optical Networking Information li Where to Find Safety and Warning Information li Cisco Optical Networking Product Documentation CD-ROM Obtaining Documentation and Submitting a Service Request CHAPTER 1 Shelf and Backplane Hardware 1.1 Overview li lii 1-1 1-2 1.2 Rack Installation 1-3 1.2.1 Reversible Mounting Bracket 1-4 1.2.2 Mounting a Single Node 1-5 1.2.3 Mounting Multiple Nodes 1-6 1.2.4 ONS 15454 Bay Assembly 1-6 1.3 Front Door 1-6 1.4 Backplane Covers 1-11 1.4.1 Lower Backplane Cover 1-12 1.4.2 Rear Cover 1-13 1.4.3 Alarm Interface Panel 1-14 1.4.4 Alarm Interface Panel Replacement 1-14 1.5 Electrical Interface Assemblies 1-15 1.5.1 EIA Installation 1-16 1.5.2 EIA Configurations 1-16 1.5.3 BNC EIA 1-18 1.5.3.1 BNC Connectors 1-19 1.5.3.2 BNC Insertion and Removal Tool 1-20 1.5.4 High-Density BNC EIA 1-20 1.5.5 MiniBNC EIA 1-21 1.5.5.1 MiniBNC Connectors 1-22 1.5.5.2 MiniBNC Insertion and Removal Tool 1-27 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 iii Contents 1.5.6 SMB EIA 1-28 1.5.7 AMP Champ EIA 1-29 1.5.8 UBIC-V EIA 1-32 1.5.9 UBIC-H EIA 1-34 1.5.10 EIA Replacement 1-38 1.6 Coaxial Cable 1-38 1.7 DS-1 Cable 1-38 1.7.1 Twisted Pair Wire-Wrap Cables 1-38 1.7.2 Electrical Interface Adapters 1-39 1.8 UBIC-V Cables 1-40 1.9 UBIC-H Cables 1-45 1.10 Ethernet Cables 1-51 1.11 Cable Routing and Management 1-53 1.11.1 Fiber Management 1-54 1.11.2 Fiber Management Using the Tie-Down Bar 1-55 1.11.3 Coaxial Cable Management 1-56 1.11.4 DS-1 Twisted-Pair Cable Management 1-56 1.11.5 AMP Champ Cable Management 1-56 1.12 Alarm Expansion Panel 1-56 1.12.1 Wire-Wrap and Pin Connections 1.13 Filler Card 1-57 1-61 1.14 Fan-Tray Assembly 1-62 1.14.1 Fan Tray Units for ONS 15454 Cards 1.14.2 Fan Speed 1-65 1.14.3 Fan Failure 1-65 1.14.4 Air Filter 1-65 1.14.5 Pilot Fuse 1-66 1.15 Power and Ground Description 1-63 1-66 1.16 Alarm, Timing, LAN, and Craft Pin Connections 1.16.1 Alarm Contact Connections 1-69 1.16.2 Timing Connections 1-70 1.16.3 LAN Connections 1-70 1.16.4 TL1 Craft Interface Installation 1-71 1-67 1.17 Cards and Slots 1-71 1.17.1 Card Slot Requirements 1-72 1.17.2 Card Replacement 1-75 1.18 Software and Hardware Compatibility 1-76 Cisco ONS 15454 Reference Manual, R8.5.x iv 78-18106-01 Contents CHAPTER 2 Common Control Cards 2-1 2.1 Common Control Card Overview 2-1 2.1.1 Cards Summary 2-1 2.1.2 Card Compatibility 2-3 2.1.3 Cross-Connect Card Compatibility 2-3 2.2 TCC2 Card 2-6 2.2.1 TCC2 Card Functionality 2-7 2.2.2 TCC2 Card-Level Indicators 2-8 2.2.3 Network-Level Indicators 2-9 2.2.4 Power-Level Indicators 2-10 2.3 TCC2P Card 2-10 2.3.1 TCC2P Functionality 2-11 2.3.1.1 System Timing Functions 2-12 2.3.2 TCC2P Card-Level Indicators 2-14 2.3.3 Network-Level Indicators 2-14 2.3.4 Power-Level Indicators 2-15 2.4 XCVT Card 2-15 2.4.1 XCVT Functionality 2-16 2.4.2 VT Mapping 2-17 2.4.3 XCVT Hosting DS3XM-6 or DS3XM-12 2.4.4 XCVT Card-Level Indicators 2-18 2-18 2.5 XC10G Card 2-19 2.5.1 XC10G Functionality 2-20 2.5.2 VT Mapping 2-21 2.5.3 XC10G Hosting DS3XM-6 or DS3XM-12 2-22 2.5.4 XC10G Card-Level Indicators 2-22 2.5.5 XCVT/XC10G/XC-VXC-10G Compatibility 2-23 2.6 XC-VXC-10G Card 2-23 2.6.1 XC-VXC-10G Functionality 2-24 2.6.2 VT Mapping 2-26 2.6.3 XC-VXC-10G Hosting DS3XM-6 or DS3XM-12 2.6.4 XC-VXC-10G Card-Level Indicators 2-27 2.6.5 XC-VXC-10G Compatibility 2-28 2-27 2.7 AIC-I Card 2-28 2.7.1 AIC-I Card-Level Indicators 2-29 2.7.2 External Alarms and Controls 2-30 2.7.3 Orderwire 2-31 2.7.4 Power Monitoring 2-32 2.7.5 User Data Channel 2-32 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 v Contents 2.7.6 Data Communications Channel CHAPTER 3 Electrical Cards 2-33 3-1 3.1 Electrical Card Overview 3-1 3.1.1 Card Summary 3-1 3.1.2 Card Compatibility 3-3 3.2 Bit Error Rate Testing 3-4 3.3 EC1-12 Card 3-5 3.3.1 EC1-12 Slots and Connectors 3-5 3.3.2 EC1-12 Faceplate and Block Diagram 3-5 3.3.3 EC1-12 Hosted by XCVT, XC10G, or XC-VXC-10G 3.3.4 EC1-12 Card-Level Indicators 3-6 3.3.5 EC1-12 Port-Level Indicators 3-7 3-6 3.4 DS1-14 and DS1N-14 Cards 3-7 3.4.1 DS1N-14 Features and Functions 3-7 3.4.2 DS1-14 and DS1N-14 Slot Compatibility 3-8 3.4.3 DS1-14 and DS1N-14 Faceplate and Block Diagram 3-8 3.4.4 DS1-14 and DS1N-14 Hosted by XCVT, XC10G, or XC-VXC-10G 3.4.5 DS1-14 and DS1N-14 Card-Level Indicators 3-9 3.4.6 DS1-14 and DS1N-14 Port-Level Indicators 3-10 3.5 DS1/E1-56 Card 3-10 3.5.1 DS1/E1-56 Slots and Connectors 3-10 3.5.2 DS1/E1-56 Faceplate and Block Diagram 3.5.3 DS1/E1-56 Card-Level Indicators 3-12 3.5.4 DS1/E1-56 Port-Level Indicators 3-13 3-11 3.6 DS3-12 and DS3N-12 Cards 3-13 3.6.1 DS3-12 and DS3N-12 Slots and Connectors 3-14 3.6.2 DS3-12 and DS3N-12 Faceplate and Block Diagram 3.6.3 DS3-12 and DS3N-12 Card-Level Indicators 3-15 3.6.4 DS3-12 and DS3N-12 Port-Level Indicators 3-16 3.7 DS3/EC1-48 Card 3-16 3.7.1 DS3/EC1-48 Slots and Connectors 3-16 3.7.2 DS3/EC1-48 Faceplate and Block Diagram 3.7.3 DS3/EC1-48 Card-Level Indicators 3-18 3.7.4 DS3/EC1-48 Port-Level Indicators 3-19 3-9 3-14 3-17 3.8 DS3i-N-12 Card 3-19 3.8.1 DS3i-N-12 Slots and Connectors 3-19 3.8.2 DS3i-N-12 Card-Level Indicators 3-21 3.8.3 DS3i-N-12 Port-Level Indicators 3-21 Cisco ONS 15454 Reference Manual, R8.5.x vi 78-18106-01 Contents 3.9 DS3-12E and DS3N-12E Cards 3-21 3.9.1 DS3-12E and DS3N-12E Slots and Connectors 3-22 3.9.2 DS3-12E Faceplate and Block Diagram 3-22 3.9.3 DS3-12E and DS3N-12E Card-Level Indicators 3-24 3.9.4 DS3-12E and DS3N-12E Port-Level Indicators 3-25 3.10 DS3XM-6 Card 3-25 3.10.1 DS3XM-6 Slots and Connectors 3-25 3.10.2 DS3XM-6 Faceplate and Block Diagram 3-25 3.10.3 DS3XM-6 Hosted By XCVT, XC10G, or XC-VXC-10G 3.10.4 DS3XM-6 Card-Level Indicators 3-26 3.10.5 DS3XM-6 Port-Level Indicators 3-27 3.11 DS3XM-12 Card 3-27 3.11.1 Backplane Configurations 3-27 3.11.2 Ported Mode 3-28 3.11.3 Portless Mode 3-28 3.11.4 Shelf Configurations 3-28 3.11.5 Protection Modes 3-29 3.11.6 Card Features 3-29 3.11.7 DS3XM-12 Slots and Connectors 3-30 3.11.8 DS3XM-12 Faceplate and Block Diagram 3.11.9 DS3XM-12 Card-Level Indicators 3-31 3.11.10 DS3XM-12 Port-Level Indicators 3-32 CHAPTER 4 Optical Cards 3-26 3-30 4-1 4.1 Optical Card Overview 4-2 4.1.1 Card Summary 4-2 4.1.2 Card Compatibility 4-4 4.2 OC3 IR 4/STM1 SH 1310 Card 4-6 4.2.1 OC3 IR 4/STM1 SH 1310 Card-Level Indicators 4-7 4.2.2 OC3 IR 4/STM1 SH 1310 Port-Level Indicators 4-7 4.3 OC3 IR/STM1 SH 1310-8 Card 4-8 4.3.1 OC3 IR/STM1 SH 1310-8 Card-Level Indicators 4-9 4.3.2 OC3 IR/STM1 SH 1310-8 Port-Level Indicators 4-9 4.4 OC12 IR/STM4 SH 1310 Card 4-9 4.4.1 OC12 IR/STM4 SH 1310 Card-Level Indicators 4-11 4.4.2 OC12 IR/STM4 SH 1310 Port-Level Indicators 4-11 4.5 OC12 LR/STM4 LH 1310 Card 4-11 4.5.1 OC12 LR/STM4 LH 1310 Card-Level Indicators 4-13 4.5.2 OC12 LR/STM4 LH 1310 Port-Level Indicators 4-13 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 vii Contents 4.6 OC12 LR/STM4 LH 1550 Card 4-13 4.6.1 OC12 LR/STM4 LH 1550 Card-Level Indicators 4-14 4.6.2 OC12 LR/STM4 LH 1550 Port-Level Indicators 4-15 4.7 OC12 IR/STM4 SH 1310-4 Card 4-15 4.7.1 OC12 IR/STM4 SH 1310-4 Card-Level Indicators 4-17 4.7.2 OC12 IR/STM4 SH 1310-4 Port-Level Indicators 4-17 4.8 OC48 IR 1310 Card 4-17 4.8.1 OC48 IR 1310 Card-Level Indicators 4-18 4.8.2 OC48 IR 1310 Port-Level Indicators 4-19 4.9 OC48 LR 1550 Card 4-19 4.9.1 OC48 LR 1550 Card-Level Indicators 4-20 4.9.2 OC48 LR 1550 Port-Level Indicators 4-21 4.10 OC48 IR/STM16 SH AS 1310 Card 4-21 4.10.1 OC48 IR/STM16 SH AS 1310 Card-Level Indicators 4-22 4.10.2 OC48 IR/STM16 SH AS 1310 Port-Level Indicators 4-23 4.11 OC48 LR/STM16 LH AS 1550 Card 4-23 4.11.1 OC48 LR/STM16 LH AS 1550 Card-Level Indicators 4-24 4.11.2 OC48 LR/STM16 LH AS 1550 Port-Level Indicators 4-25 4.12 OC48 ELR/STM16 EH 100 GHz Cards 4-25 4.12.1 OC48 ELR 100 GHz Card-Level Indicators 4-27 4.12.2 OC48 ELR 100 GHz Port-Level Indicators 4-27 4.13 OC48 ELR 200 GHz Cards 4-27 4.13.1 OC48 ELR 200 GHz Card-Level Indicators 4-29 4.13.2 OC48 ELR 200 GHz Port-Level Indicators 4-29 4.14 OC192 SR/STM64 IO 1310 Card 4-29 4.14.1 OC192 SR/STM64 IO 1310 Card-Level Indicators 4-30 4.14.2 OC192 SR/STM64 IO 1310 Port-Level Indicators 4-31 4.15 OC192 IR/STM64 SH 1550 Card 4-31 4.15.1 OC192 IR/STM64 SH 1550 Card-Level Indicators 4-32 4.15.2 OC192 IR/STM64 SH 1550 Port-Level Indicators 4-33 4.16 OC192 LR/STM64 LH 1550 Card 4-33 4.16.1 OC192 LR/STM64 LH 1550 Card-Level Indicators 4-38 4.16.2 OC192 LR/STM64 LH 1550 Port-Level Indicators 4-38 4.17 OC192 LR/STM64 LH ITU 15xx.xx Card 4-38 4.17.1 OC192 LR/STM64 LH ITU 15xx.xx Card-Level Indicators 4-40 4.17.2 OC192 LR/STM64 LH ITU 15xx.xx Port-Level Indicators 4-41 4.18 15454_MRC-12 Multirate Card 4-41 4.18.1 Slot Compatibility by Cross-Connect Card 4-42 Cisco ONS 15454 Reference Manual, R8.5.x viii 78-18106-01 Contents 4.18.2 Ports and Line Rates 4-43 4.18.3 15454_MRC-12 Card-Level Indicators 4-45 4.18.4 15454_MRC-12 Port-Level Indicators 4-46 4.19 MRC-2.5G-4 Multirate Card 4-46 4.19.1 Slot Compatibility by Cross-Connect Card 4.19.2 Ports and Line Rates 4-48 4.19.3 MRC-2.5G-4 Card-Level Indicators 4-49 4.19.4 MRC-2.5G-4 Port-Level Indicators 4-49 4-48 4.20 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Cards 4-50 4.20.1 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Card-Level Indicators 4.20.2 OC192SR1/STM64IO Short Reach and OC-192/STM-64 Any Reach Port-Level Indicators 4-52 4-52 4.21 Optical Card SFPs and XFPs 4-52 4.21.1 Compatibility by Card 4-52 4.21.2 SFP Description 4-54 4.21.3 XFP Description 4-55 4.21.4 PPM Provisioning 4-56 CHAPTER 5 Ethernet Cards 5-1 5.1 Ethernet Card Overview 5-2 5.1.1 Ethernet Cards 5-2 5.1.2 Card Compatibility 5-3 5.2 E100T-12 Card 5-4 5.2.1 Slot Compatibility 5-5 5.2.2 E100T-12 Card-Level Indicators 5-6 5.2.3 E100T-12 Port-Level Indicators 5-6 5.2.4 Cross-Connect Compatibility 5-6 5.3 E100T-G Card 5-6 5.3.1 Slot Compatibility 5-8 5.3.2 E100T-G Card-Level Indicators 5-8 5.3.3 E100T-G Port-Level Indicators 5-8 5.3.4 Cross-Connect Compatibility 5-8 5.4 E1000-2 Card 5-9 5.4.1 Slot Compatibility 5-10 5.4.2 E1000-2 Card-Level Indicators 5-10 5.4.3 E1000-2 Port-Level Indicators 5-10 5.4.4 Cross-Connect Compatibility 5-11 5.5 E1000-2-G Card 5-11 5.5.1 E1000-2-G Card-Level Indicators 5-13 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 ix Contents 5.5.2 E1000-2-G Port-Level Indicators 5-13 5.5.3 Cross-Connect Compatibility 5-13 5.6 G1000-4 Card 5-14 5.6.1 STS-24c Restriction 5-15 5.6.2 G1000-4 Card-Level Indicators 5-15 5.6.3 G1000-4 Port-Level Indicators 5-15 5.6.4 Slot Compatibility 5-16 5.7 G1K-4 Card 5-16 5.7.1 STS-24c Restriction 5-17 5.7.2 G1K-4 Compatibility 5-18 5.7.3 G1K-4 Card-Level Indicators 5-18 5.7.4 G1K-4 Port-Level Indicators 5-18 5.8 ML100T-12 Card 5-19 5.8.1 ML100T-12 Card-Level Indicators 5-20 5.8.2 ML100T-12 Port-Level Indicators 5-21 5.8.3 Cross-Connect and Slot Compatibility 5-21 5.9 ML100X-8 Card 5-21 5.9.1 ML100X-8 Card-Level Indicators 5-22 5.9.2 ML100X-8 Port-Level Indicators 5-23 5.9.3 Cross-Connect and Slot Compatibility 5-23 5.10 ML1000-2 Card 5-23 5.10.1 ML1000-2 Card-Level Indicators 5-24 5.10.2 ML1000-2 Port-Level Indicators 5-25 5.10.3 Cross-Connect and Slot Compatibility 5-25 5.11 ML-MR-10 Card 5-25 5.11.1 ML-MR-10 Card-Level Indicators 5-27 5.11.2 ML-MR-10 Port-Level Indicators 5-27 5.11.3 Cross-Connect and Slot Compatibility 5-27 5.12 CE-100T-8 Card 5-28 5.12.1 CE-100T-8 Card-Level Indicators 5-30 5.12.2 CE-100T-8 Port-Level Indicators 5-30 5.12.3 Cross-Connect and Slot Compatibility 5-30 5.13 CE-1000-4 Card 5-30 5.13.1 CE-1000-4 Card-Level Indicators 5-33 5.13.2 CE-1000-4 Port-Level Indicators 5-33 5.13.3 Cross-Connect and Slot Compatibility 5-33 5.14 CE-MR-10 Card 5-34 5.14.1 CE-MR-10 Card-Level Indicators 5-35 5.14.2 CE-MR-10 Port-Level Indicators 5-36 Cisco ONS 15454 Reference Manual, R8.5.x x 78-18106-01 Contents 5.14.3 Cross-Connect and Slot Compatibility 5.15 Ethernet Card GBICs and SFPs 5-36 5.15.1 Compatibility by Card 5-37 5.15.2 GBIC Description 5-38 5.15.3 G1K-4 DWDM and CWDM GBICs 5.15.4 SFP Description 5-41 CHAPTER 6 Storage Access Networking Cards 5-36 5-39 6-1 6.1 FC_MR-4 Card Overview 6-1 6.1.1 FC_MR-4 Card-Level Indicators 6-3 6.1.2 FC_MR-4 Port-Level Indicators 6-4 6.1.3 FC_MR-4 Compatibility 6-4 6.2 FC_MR-4 Card Modes 6-4 6.2.1 Line-Rate Card Mode 6-4 6.2.2 Enhanced Card Mode 6-5 6.2.2.1 Mapping 6-5 6.2.2.2 SW -LCAS 6-5 6.2.2.3 Distance Extension 6-5 6.2.2.4 Differential Delay Features 6-6 6.2.2.5 Interoperability Features 6-6 6.2.3 Link Integrity 6-7 6.2.4 Link Recovery 6-7 6.3 FC_MR-4 Card Application 6.4 FC_MR-4 Card GBICs CHAPTER 7 Card Protection 6-7 6-8 7-1 7.1 Electrical Card Protection 7-1 7.1.1 1:1 Protection 7-2 7.1.2 1:N Protection 7-3 7.1.2.1 Revertive Switching 7-4 7.1.2.2 1:N Protection Guidelines 7-4 7.2 Electrical Card Protection and the Backplane 7.2.1 Standard BNC Protection 7-11 7.2.2 High-Density BNC Protection 7-11 7.2.3 MiniBNC Protection 7-12 7.2.4 SMB Protection 7-12 7.2.5 AMP Champ Protection 7-12 7.2.6 UBIC Protection 7-12 7.3 OC-N Card Protection 7-5 7-13 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xi Contents 7.3.1 1+1 Protection 7-13 7.3.2 Optimized 1+1 Protection 7.4 Unprotected Cards 7-13 7-14 7.5 External Switching Commands CHAPTER 8 7-14 Cisco Transport Controller Operation 8-1 8.1 CTC Software Delivery Methods 8-1 8.1.1 CTC Software Installed on the TCC2/TCC2P Card 8-1 8.1.2 CTC Software Installed on the PC or UNIX Workstation 8.2 CTC Installation Overview 8-4 8.3 PC and UNIX Workstation Requirements 8.4 ONS 15454 Connection 8-3 8-4 8-7 8.5 CTC Login 8-7 8.5.1 Legal Disclaimer 8-8 8.5.2 Login Node Group 8-8 8.6 CTC Window 8-8 8.6.1 Node View 8-9 8.6.1.1 CTC Card Colors 8-9 8.6.1.2 Node View Card Shortcuts 8.6.1.3 Node View Tabs 8-11 8.6.2 Network View 8-12 8.6.2.1 Network View Tabs 8-13 8.6.2.2 CTC Node Colors 8-14 8.6.2.3 DCC Links 8-14 8.6.2.4 Link Consolidation 8-15 8.6.3 Card View 8-15 8.6.4 Print or Export CTC Data 8-17 8-11 8.7 Using the CTC Launcher Application to Manage Multiple ONS Nodes 8.8 TCC2/TCC2P Card Reset 8-21 8.9 TCC2/TCC2P Card Database 8.10 Software Revert CHAPTER 9 Security 8-18 8-21 8-22 9-1 9.1 User IDs and Security Levels 9-1 9.2 User Privileges and Policies 9-1 9.2.1 User Privileges by CTC Action 9-2 9.2.2 Security Policies 9-6 9.2.2.1 Superuser Privileges for Provisioning Users 9-6 Cisco ONS 15454 Reference Manual, R8.5.x xii 78-18106-01 Contents 9.2.2.2 Idle User Timeout 9-7 9.2.2.3 User Password, Login, and Access Policies 9.2.2.4 Secure Access 9-8 9-7 9.3 Audit Trail 9-8 9.3.1 Audit Trail Log Entries 9-8 9.3.2 Audit Trail Capacities 9-9 9.4 RADIUS Security 9-9 9.4.1 RADIUS Authentication 9.4.2 Shared Secrets 9-10 CHAPTER 10 Timing 9-9 10-1 10.1 Timing Parameters 10.2 Network Timing 10-1 10-2 10.3 Synchronization Status Messaging 10-3 10.3.1 SONET SSM Messages 10-4 10.3.2 SDH SSM Messages 10-4 CHAPTER 11 Circuits and Tunnels 11.1 Overview 11-1 11-2 11.2 Circuit Properties 11-2 11.2.1 Concatenated STS Time Slot Assignments 11-4 11.2.2 Circuit Status 11-6 11.2.3 Circuit States 11-7 11.2.4 Circuit Protection Types 11-9 11.2.5 Circuit Information in the Edit Circuit Window 11-10 11.3 Cross-Connect Card Bandwidth 11.4 Portless Transmux 11-15 11.5 DCC Tunnels 11-16 11.5.1 Traditional DCC Tunnels 11.5.2 IP-Encapsulated Tunnels 11.6 SDH Tunneling 11-12 11-17 11-18 11-18 11.7 Multiple Destinations for Unidirectional Circuits 11-18 11.8 Monitor Circuits 11-18 11.8.1 Monitor Circuits using portless ports as a source on DS3XM-12 11-19 11.9 Path ProtectionCircuits 11-19 11.9.1 Open-Ended Path Protection Circuits 11-20 11.9.2 Go-and-Return Path Protection Routing 11-21 11.10 BLSR Protection Channel Access Circuits 11-21 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xiii Contents 11.11 BLSR STS and VT Squelch Tables 11-22 11.11.1 BLSR STS Squelch Table 11-22 11.11.2 BLSR VT Squelch Table 11-23 11.12 IEEE 802.17 Resilient Packet Ring Circuit Display 11.13 Section and Path Trace 11-23 11-24 11.14 Path Signal Label, C2 Byte 11-25 11.15 Automatic Circuit Routing 11-27 11.15.1 Bandwidth Allocation and Routing 11-28 11.15.2 Secondary Sources and Destinations 11-28 11.16 Manual Circuit Routing 11-29 11.17 Constraint-Based Circuit Routing 11-33 11.18 Virtual Concatenated Circuits 11-34 11.18.1 VCAT Circuit States 11-34 11.18.2 VCAT Member Routing 11-34 11.18.3 Link Capacity Adjustment 11-36 11.18.4 VCAT Circuit Size 11-37 11.18.5 Open-Ended VCAT 11-38 11.18.5.1 Open-Ended VCAT Protection 11-39 11.19 Bridge and Roll 11-40 11.19.1 Rolls Window 11-40 11.19.2 Roll Status 11-42 11.19.3 Single and Dual Rolls 11-43 11.19.4 Two Circuit Bridge and Roll 11-45 11.19.5 Protected Circuits 11-46 11.20 Merged Circuits 11-46 11.21 Reconfigured Circuits 11.22 VLAN Management 11-47 11-47 11.23 Server Trails 11-47 11.23.1 Server Trail Protection Types 11-48 11.23.2 VCAT Circuit Routing over Server Trails 11-48 11.23.2.1 Shared Resource Link Group 11-49 CHAPTER 12 SONET Topologies and Upgrades 12-1 12.1 SONET Rings and TCC2/TCC2P Cards 12.2 Bidirectional Line Switched Rings 12.2.1 Two-Fiber BLSRs 12-3 12.2.2 Four-Fiber BLSRs 12-6 12.2.3 BLSR Bandwidth 12-9 12-1 12-3 Cisco ONS 15454 Reference Manual, R8.5.x xiv 78-18106-01 Contents 12.2.4 BLSR Application Example 12-10 12.2.5 BLSR Fiber Connections 12-13 12.3 Path Protection 12-14 12.4 Dual-Ring Interconnect 12-19 12.4.1 BLSR DRI 12-19 12.4.2 Path Protection DRI 12-23 12.4.3 Path Protection/BLSR DRI Handoff Configurations 12.5 Comparison of the Protection Schemes 12.6 Subtending Rings 12-26 12-28 12-29 12.7 Linear ADM Configurations 12-31 12.8 Path-Protected Mesh Networks 12-31 12.9 Four-Shelf Node Configurations 12-33 12.10 STS around the Ring 12-34 12.11 OC-N Speed Upgrades 12-35 12.11.1 Span Upgrade Wizard 12-38 12.11.2 Manual Span Upgrades 12-38 12.12 In-Service Topology Upgrades 12-38 12.12.1 Unprotected Point-to-Point or Linear ADM to Path Protection 12.12.2 Point-to-Point or Linear ADM to Two-Fiber BLSR 12-40 12.12.3 Path Protection to Two-Fiber BLSR 12-40 12.12.4 Two-Fiber BLSR to Four-Fiber BLSR 12-41 12.12.5 Add or Remove a Node from a Topology 12-41 CHAPTER 13 Management Network Connectivity 13.1 IP Networking Overview 12-39 13-1 13-1 13.2 IP Addressing Scenarios 13-2 13.2.1 IP Scenario 1: CTC and ONS 15454s on Same Subnet 13-3 13.2.2 IP Scenario 2: CTC and ONS 15454 Nodes Connected to a Router 13-3 13.2.3 IP Scenario 3: Using Proxy ARP to Enable an ONS 15454 Gateway 13-4 13.2.4 IP Scenario 4: Default Gateway on a CTC Computer 13-6 13.2.5 IP Scenario 5: Using Static Routes to Connect to LANs 13-7 13.2.6 IP Scenario 6: Using OSPF 13-10 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server 13-12 13.2.8 IP Scenario 8: Dual GNEs on a Subnet 13-18 13.2.9 IP Scenario 9: IP Addressing with Secure Mode Enabled 13-20 13.2.9.1 Secure Mode Behavior 13-20 13.2.9.2 Secure Node Locked and Unlocked Behavior 13-23 13.3 Routing Table 13-24 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xv Contents 13.4 External Firewalls 13.5 Open GNE 13-25 13-27 13.6 TCP/IP and OSI Networking 13-29 13.6.1 Point-to-Point Protocol 13-30 13.6.2 Link Access Protocol on the D Channel 13-31 13.6.3 OSI Connectionless Network Service 13-31 13.6.4 OSI Routing 13-34 13.6.4.1 End System-to-Intermediate System Protocol 13-36 13.6.4.2 Intermediate System-to-Intermediate System Protocol 13-36 13.6.5 TARP 13-37 13.6.5.1 TARP Processing 13-38 13.6.5.2 TARP Loop Detection Buffer 13-39 13.6.5.3 Manual TARP Adjacencies 13-39 13.6.5.4 Manual TID to NSAP Provisioning 13-40 13.6.6 TCP/IP and OSI Mediation 13-40 13.6.7 OSI Virtual Routers 13-41 13.6.8 IP-over-CLNS Tunnels 13-43 13.6.8.1 Provisioning IP-over-CLNS Tunnels 13-44 13.6.8.2 IP-over-CLNS Tunnel Scenario 1: ONS Node to Other Vendor GNE 13-45 13.6.8.3 IP-over-CLNS Tunnel Scenario 2: ONS Node to Router 13-46 13.6.8.4 IP-over-CLNS Tunnel Scenario 3: ONS Node to Router Across an OSI DCN 13-47 13.6.9 OSI/IP Networking Scenarios 13-49 13.6.9.1 OSI/IP Scenario 1: IP OSS, IP DCN, ONS GNE, IP DCC, and ONS ENE 13-50 13.6.9.2 OSI/IP Scenario 2: IP OSS, IP DCN, ONS GNE, OSI DCC, and Other Vendor ENE 13-50 13.6.9.3 OSI/IP Scenario 3: IP OSS, IP DCN, Other Vendor GNE, OSI DCC, and ONS ENE 13-52 13.6.9.4 OSI/IP Scenario 4: Multiple ONS DCC Areas 13-54 13.6.9.5 OSI/IP Scenario 5: GNE Without an OSI DCC Connection 13-55 13.6.9.6 OSI/IP Scenario 6: IP OSS, OSI DCN, ONS GNE, OSI DCC, and Other Vendor ENE 13-56 13.6.9.7 OSI/IP Scenario 7: OSI OSS, OSI DCN, Other Vender GNE, OSI DCC, and ONS NEs 13-57 13.6.9.8 OSI/IP Scenario 8: OSI OSS, OSI DCN, ONS GNE, OSI DCC, and Other Vender NEs 13-59 13.6.10 Provisioning OSI in CTC 13-61 13.7 IPv6 Network Compatibility 13-62 13.8 FTP Support for ENE Database Backup CHAPTER 14 Alarm Monitoring and Management 14.1 Overview 13-62 14-1 14-1 14.2 LCD Alarm Counts 14-1 Cisco ONS 15454 Reference Manual, R8.5.x xvi 78-18106-01 Contents 14.3 Alarm Information 14-2 14.3.1 Viewing Alarms With Each Node’s Time Zone 14-4 14.3.2 Controlling Alarm Display 14-4 14.3.3 Filtering Alarms 14-4 14.3.4 Viewing Alarm-Affected Circuits 14-5 14.3.5 Conditions Tab 14-5 14.3.6 Controlling the Conditions Display 14-6 14.3.6.1 Retrieving and Displaying Conditions 14-6 14.3.6.2 Conditions Column Descriptions 14-6 14.3.6.3 Filtering Conditions 14-7 14.3.7 Viewing History 14-7 14.3.7.1 History Column Descriptions 14-8 14.3.7.2 Retrieving and Displaying Alarm and Condition History 14.3.8 Alarm History and Log Buffer Capacities 14-9 14.4 Alarm Severities 14-8 14-9 14.5 Alarm Profiles 14-9 14.5.1 Creating and Modifying Alarm Profiles 14.5.2 Alarm Profile Buttons 14-11 14.5.3 Alarm Profile Editing 14-12 14.5.4 Alarm Severity Options 14-12 14.5.5 Row Display Options 14-12 14.5.6 Applying Alarm Profiles 14-13 14-10 14.6 Alarm Suppression 14-13 14.6.1 Alarms Suppressed for Maintenance 14-13 14.6.2 Alarms Suppressed by User Command 14-14 14.7 External Alarms and Controls 14-14 14.7.1 External Alarms 14-14 14.7.2 User Defined Alarm Types 14-15 14.7.3 External Controls 14-15 CHAPTER 15 Performance Monitoring 15-1 15.1 Threshold Performance Monitoring 15-2 15.2 Intermediate Path Performance Monitoring 15-3 15.3 Pointer Justification Count Performance Monitoring 15.4 Performance Monitoring Parameter Definitions 15-4 15-5 15.5 Performance Monitoring for Electrical Cards 15-12 15.5.1 EC1-12 Card Performance Monitoring Parameters 15-12 15.5.2 DS1/E1-56 Card Performance Monitoring Parameters 15-14 15.5.3 DS1-14 and DS1N-14 Card Performance Monitoring Parameters 15-16 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xvii Contents 15.5.3.1 DS-1 Facility Data Link Performance Monitoring 15-18 15.5.4 DS3-12 and DS3N-12 Card Performance Monitoring Parameters 15-18 15.5.5 DS3-12E and DS3N-12E Card Performance Monitoring Parameters 15-19 15.5.6 DS3i-N-12 Card Performance Monitoring Parameters 15-21 15.5.7 DS3XM-6 Card Performance Monitoring Parameters 15-23 15.5.8 DS3XM-12 Card Performance Monitoring Parameters 15-25 15.5.9 DS3/EC1-48 Card Performance Monitoring Parameters 15-27 15.6 Performance Monitoring for Ethernet Cards 15-29 15.6.1 E-Series Ethernet Card Performance Monitoring Parameters 15-29 15.6.1.1 E-Series Ethernet Statistics Window 15-29 15.6.1.2 E-Series Ethernet Utilization Window 15-31 15.6.1.3 E-Series Ethernet History Window 15-31 15.6.2 G-Series Ethernet Card Performance Monitoring Parameters 15-32 15.6.2.1 G-Series Ethernet Statistics Window 15-32 15.6.2.2 G-Series Ethernet Utilization Window 15-33 15.6.2.3 G-Series Ethernet History Window 15-34 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters 15-34 15.6.3.1 ML-Series Ether Ports Statistics Window 15-34 15.6.3.2 ML-Series Card Ether Ports Utilization Window 15-36 15.6.3.3 ML-Series Card Ether Ports History Window 15-37 15.6.3.4 ML-Series POS Ports Window 15-37 15.6.3.5 ML-Series RPR Span Window 15-38 15.6.4 CE-Series Ethernet Card Performance Monitoring Parameters 15-43 15.6.4.1 CE-Series Card Ether Port Statistics Window 15-44 15.6.4.2 CE-Series Card Ether Ports Utilization Window 15-46 15.6.4.3 CE-Series Card Ether Ports History Window 15-47 15.6.4.4 CE-Series Card POS Ports Statistics Parameters 15-47 15.6.4.5 CE-Series Card POS Ports Utilization Window 15-48 15.6.4.6 CE-Series Card POS Ports History Window 15-48 15.7 Performance Monitoring for Optical Cards 15-48 15.8 Performance Monitoring for Optical Multirate Cards 15-51 15.9 Performance Monitoring for Storage Access Networking Cards 15.9.1 FC_MR-4 Statistics Window 15-53 15.9.2 FC_MR-4 Utilization Window 15-54 15.9.3 FC_MR-4 History Window 15-55 CHAPTER 16 SNMP 15-52 16-1 16.1 SNMP Overview 16-1 16.2 Basic SNMP Components 16-2 Cisco ONS 15454 Reference Manual, R8.5.x xviii 78-18106-01 Contents 16.3 SNMP External Interface Requirement 16.4 SNMP Version Support 16-4 16.5 SNMP Message Types 16-4 16-4 16.6 SNMP Management Information Bases 16-5 16.6.1 IETF-Standard MIBs for the ONS 15454 16-5 16.6.2 Proprietary ONS 15454 MIBs 16-6 16.6.3 Generic Threshold and Performance Monitoring MIBs 16.7 SNMP Trap Content 16-9 16.7.1 Generic and IETF Traps 16.7.2 Variable Trap Bindings 16.8 SNMP Community Names 16.9 Proxy Over Firewalls 16-7 16-9 16-10 16-16 16-16 16.10 Remote Monitoring 16-16 16.10.1 64-Bit RMON Monitoring over DCC 16-17 16.10.1.1 Row Creation in MediaIndependentTable 16-17 16.10.1.2 Row Creation in cMediaIndependentHistoryControlTable 16.10.2 HC-RMON-MIB Support 16-18 16.10.3 Ethernet Statistics RMON Group 16-18 16.10.3.1 Row Creation in etherStatsTable 16-18 16.10.3.2 Get Requests and GetNext Requests 16-19 16.10.3.3 Row Deletion in etherStatsTable 16-19 16.10.3.4 64-Bit etherStatsHighCapacityTable 16-19 16.10.4 History Control RMON Group 16-19 16.10.4.1 History Control Table 16-19 16.10.4.2 Row Creation in historyControlTable 16-19 16.10.4.3 Get Requests and GetNext Requests 16-20 16.10.4.4 Row Deletion in historyControl Table 16-20 16.10.5 Ethernet History RMON Group 16-20 16.10.5.1 64-Bit etherHistoryHighCapacityTable 16-20 16.10.6 Alarm RMON Group 16-20 16.10.6.1 Alarm Table 16-21 16.10.6.2 Row Creation in alarmTable 16-21 16.10.6.3 Get Requests and GetNext Requests 16-22 16.10.6.4 Row Deletion in alarmTable 16-22 16.10.7 Event RMON Group 16-23 16.10.7.1 Event Table 16-23 16.10.7.2 Log Table 16-23 16-18 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xix Contents APPENDIX A Hardware Specifications A-1 A.1 Shelf Specifications A-1 A.1.1 Bandwidth A-1 A.1.2 Configurations A-2 A.1.3 Cisco Transport Controller A-2 A.1.4 External LAN Interface A-2 A.1.5 TL1 Craft Interface A-2 A.1.6 Modem Interface A-2 A.1.7 Alarm Interface A-3 A.1.8 EIA Interface A-3 A.1.9 BITS Interface A-3 A.1.10 System Timing A-3 A.1.11 System Power A-3 A.1.12 Fan Tray A-4 A.1.13 System Environmental Specifications A.1.14 Dimensions A-4 A.2 SFP, XFP, and GBIC Specifications A.3 General Card Specifications A.3.1 Power A-7 A.3.2 Temperature A-10 A-4 A-5 A-7 A.4 Common Control Card Specifications A-12 A.4.1 TCC2 Card Specifications A-12 A.4.2 TCC2P Card Specifications A-13 A.4.3 XCVT Card Specifications A-14 A.4.4 XC10G Card Specifications A-14 A.4.5 XC-VXC-10G Card Specifications A-15 A.4.6 AIC-I Card Specifications A-15 A.4.7 AEP Specifications A-16 A.5 Electrical Card Specifications A-17 A.5.1 EC1-12 Card Specifications A-17 A.5.2 DS1-14 and DS1N-14 Card Specifications A-18 A.5.3 DS1/E1-56 Card Specifications A-19 A.5.4 DS3/EC1-48 Card Specifications A-20 A.5.5 DS3-12 and DS3N-12 Card Specifications A-21 A.5.6 DS3i-N-12 Card Specifications A-23 A.5.7 DS3-12E and DS3N-12E Card Specifications A-24 A.5.8 DS3XM-12 Card Specifications A-25 A.5.9 DS3XM-6 Card Specifications A-26 A.5.10 FILLER Card Specifications A-27 Cisco ONS 15454 Reference Manual, R8.5.x xx 78-18106-01 Contents A.6 Optical Card Specifications A-27 A.6.1 OC3 IR 4/STM1 SH 1310 Card Specifications A-28 A.6.2 OC3 IR/STM1SH 1310-8 Card Specifications A-29 A.6.3 OC12 IR/STM4 SH 1310 Card Specifications A-30 A.6.4 OC12 LR/STM4 LH 1310 Card Specifications A-31 A.6.5 OC12 LR/STM4 LH 1550 Card Specifications A-32 A.6.6 OC12 IR/STM4 SH 1310-4 Specifications A-33 A.6.7 OC48 IR 1310 Card Specifications A-34 A.6.8 OC48 LR 1550 Card Specifications A-35 A.6.9 OC48 IR/STM16 SH AS 1310 Card Specifications A-35 A.6.10 OC48 LR/STM16 LH AS 1550 Card Specifications A-36 A.6.11 OC48 ELR/STM 16 EH 100 GHz Card Specifications A-37 A.6.12 OC48 ELR 200 GHz Card Specifications A-38 A.6.13 OC192 SR/STM64 IO 1310 Card Specifications A-39 A.6.14 OC192 IR/STM64 SH 1550 Card Specifications A-40 A.6.15 OC192 LR/STM64 LH 1550 Card Specifications A-41 A.6.16 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications A-42 A.6.17 15454_MRC-12 Card Specifications A-44 A.6.18 MRC-2.5G-4 Card Specifications A-45 A.6.19 OC192SR1/STM64IO Short Reach Card Specifications A-47 A.6.20 OC192/STM64 Any Reach Card Specifications A-47 A.7 Ethernet Card Specifications A-48 A.7.1 E100T-12 Card Specifications A-48 A.7.2 E100T-G Card Specifications A-49 A.7.3 E1000-2 Card Specifications A-49 A.7.4 E1000-2-G Card Specifications A-49 A.7.5 CE-1000-4 Card Specifications A-50 A.7.6 CE-100T-8 Card Specifications A-50 A.7.7 CE-MR-10 Card Specifications A-51 A.7.8 G1K-4 Card Specifications A-51 A.7.9 ML100T-12 Card Specifications A-51 A.7.10 ML1000-2 Card Specifications A-52 A.7.11 ML100X-8 Card Specifications A-52 A.7.12 ML-MR-10 Card Specifications A-52 A.8 Storage Access Networking Card Specifications APPENDIX B Administrative and Service States B.1 Service States A-53 B-1 B-1 B.2 Administrative States B-2 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xxi Contents B.3 Service State Transitions B-3 B.3.1 Card Service State Transitions B-3 B.3.2 Port and Cross-Connect Service State Transitions B-5 B.3.3 Pluggable Equipment Service State Transitions B-10 APPENDIX C Network Element Defaults C-1 C.1 Network Element Defaults Description C-1 C.2 Card Default Settings C-2 C.2.1 Configuration Defaults C-2 C.2.2 Threshold Defaults C-3 C.2.3 Defaults by Card C-4 C.2.3.1 DS-1 Card Default Settings C-4 C.2.3.2 DS1/E1-56 Card Default Settings C-7 C.2.3.3 DS-3 Card Default Settings C-13 C.2.3.4 DS3/EC1-48 Card Default Settings C-14 C.2.3.5 DS3E Card Default Settings C-19 C.2.3.6 DS3I Card Default Settings C-21 C.2.3.7 DS3XM-6 Card Default Settings C-24 C.2.3.8 DS3XM-12 Card Default Settings C-26 C.2.3.9 EC1-12 Card Default Settings C-30 C.2.3.10 FC_MR-4 Card Default Settings C-32 C.2.3.11 Ethernet Card Default Settings C-33 C.2.3.12 OC-3 Card Default Settings C-35 C.2.3.13 OC3-8 Card Default Settings C-38 C.2.3.14 OC-12 Card Default Settings C-41 C.2.3.15 OC12-4 Card Default Settings C-45 C.2.3.16 OC-48 Card Default Settings C-49 C.2.3.17 OC-192 Card Default Settings C-54 C.2.3.18 OC192-XFP Default Settings C-59 C.2.3.19 MRC-12 Card Default Settings C-65 C.2.3.20 MRC-2.5G-4 Card Default Settings C-82 C.3 Node Default Settings C-99 C.3.1 Time Zones C-117 C.4 CTC Default Settings C-120 INDEX Cisco ONS 15454 Reference Manual, R8.5.x xxii 78-18106-01 F I G U R E S Figure 1-1 Cisco ONS 15454 ANSI Dimensions Figure 1-2 Mounting an ONS 15454 in a Rack Figure 1-3 The ONS 15454 Front Door Figure 1-4 Cisco ONS 15454 Deep Door Figure 1-5 ONS 15454 Front Door Ground Strap 1-9 Figure 1-6 Removing the ONS 15454 Front Door 1-10 Figure 1-7 Front-Door Erasable Label Figure 1-8 Laser Warning on the Front-Door Label Figure 1-9 Backplane Covers Figure 1-10 Removing the Lower Backplane Cover Figure 1-11 Backplane Attachment for Cover Figure 1-12 Installing the Plastic Rear Cover with Spacers Figure 1-13 BNC Backplane for Use in 1:1 Protection Schemes Figure 1-14 BNC Insertion and Removal Tool Figure 1-15 High-Density BNC Backplane for Use in 1:N Protection Schemes Figure 1-16 MiniBNC Backplane for Use in 1:N Protection Schemes Figure 1-17 MiniBNC Insertion and Removal Tool Figure 1-18 SMB EIA Backplane Figure 1-19 AMP Champ EIA Backplane Figure 1-20 UBIC-V Slot Designations Figure 1-21 UBIC-H EIA Connector Labeling Figure 1-22 DS-1 Electrical Interface Adapter (Balun) Figure 1-23 Cable Connector Pins Figure 1-24 UBIC-V DS-1 Cable Schematic Diagram Figure 1-25 UBIC-V DS-3/EC-1 Cable Schematic Diagram Figure 1-26 Cable Connector Pins Figure 1-27 UBIC-H DS-1 Cable Schematic Diagram Figure 1-28 UBIC-H DS-3/EC-1 Cable Schematic Diagram Figure 1-29 100BaseT Connector Pins Figure 1-30 Straight-Through Cable 1-4 1-5 1-7 1-8 1-11 1-11 1-12 1-12 1-13 1-14 1-19 1-20 1-21 1-23 1-28 1-29 1-30 1-33 1-35 1-39 1-40 1-42 1-45 1-47 1-48 1-51 1-52 1-52 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xxiii Figures Figure 1-31 Crossover Cable Figure 1-32 Managing Cables on the Front Panel Figure 1-33 Fiber Capacity 1-54 Figure 1-34 Tie-Down Bar 1-55 Figure 1-35 AEP Printed Circuit Board Assembly Figure 1-36 AEP Block Diagram Figure 1-37 AEP Wire-Wrap Connections to Backplane Pins Figure 1-38 Alarm Input Circuit Diagram Figure 1-39 Alarm Output Circuit Diagram Figure 1-40 Detectable Filler Card Faceplate Figure 1-41 Ground Posts on the ONS 15454 Backplane Figure 1-42 ONS 15454 Backplane Pinouts (Release 3.4 or Later) Figure 1-43 ONS 15454 Backplane Pinouts Figure 1-44 Installing Cards in the ONS 15454 Figure 2-1 TCC2 Card Faceplate and Block Diagram Figure 2-2 TCC2P Faceplate and Block Diagram Figure 2-3 XCVT Faceplate and Block Diagram Figure 2-4 XCVT Cross-Connect Matrix Figure 2-5 XC10G Faceplate and Block Diagram Figure 2-6 XC10G Cross-Connect Matrix Figure 2-7 XC-VXC-10G Faceplate and Block Diagram Figure 2-8 XC-VXC-10G Cross-Connect Matrix 2-26 Figure 2-9 AIC-I Faceplate and Block Diagram 2-29 Figure 2-10 RJ-11 Connector Figure 3-1 EC1-12 Faceplate and Block Diagram 3-6 Figure 3-2 DS1-14 Faceplate and Block Diagram 3-8 Figure 3-3 DS1N-14 Faceplate and Block Diagram Figure 3-4 DS1/E1-56 Faceplate and Block Diagram Figure 3-5 DS3-12 Faceplate and Block Diagram Figure 3-6 DS3N-12 Faceplate and Block Diagram Figure 3-7 DS3/EC1-48 Faceplate and Block Diagram Figure 3-8 DS3i-N-12 Faceplate and Block Diagram Figure 3-9 DS3-12E Faceplate and Block Diagram Figure 3-10 DS3N-12E Faceplate and Block Diagram 3-24 Figure 3-11 DS3XM-6 Faceplate and Block Diagram 3-26 1-53 1-54 1-57 1-57 1-58 1-59 1-60 1-62 1-67 1-68 1-69 1-72 2-7 2-11 2-16 2-17 2-20 2-21 2-24 2-32 3-9 3-12 3-14 3-15 3-18 3-20 3-23 Cisco ONS 15454 Reference Manual, R8.5.x xxiv 78-18106-01 Figures Figure 3-12 DS3XM-12 Faceplate and Block Diagram Figure 4-1 OC3 IR 4/STM1 SH 1310 Faceplate and Block Diagram 4-6 Figure 4-2 OC3IR/STM1 SH 1310-8 Faceplate and Block Diagram 4-8 Figure 4-3 OC12 IR/STM4 SH 1310 Faceplate and Block Diagram 4-10 Figure 4-4 OC12 LR/STM4 LH 1310 Faceplate and Block Diagram 4-12 Figure 4-5 OC12 LR/STM4 LH 1550 Faceplate and Block Diagram 4-14 Figure 4-6 OC12 IR/STM4 SH 1310-4 Faceplate and Block Diagram Figure 4-7 OC48 IR 1310 Faceplate and Block Diagram 4-18 Figure 4-8 OC48 LR 1550 Faceplate and Block Diagram 4-20 Figure 4-9 OC48 IR/STM16 SH AS 1310 Faceplate and Block Diagram 4-22 Figure 4-10 OC48 LR/STM16 LH AS 1550 Faceplate and Block Diagram 4-24 Figure 4-11 OC48 ELR/STM16 EH 100 GHz Faceplate and Block Diagram Figure 4-12 OC48 ELR 200 GHz Faceplate and Block Diagram Figure 4-13 OC192 SR/STM64 IO 1310 Faceplate and Block Diagram 4-30 Figure 4-14 OC192 IR/STM64 SH 1550 Faceplate and Block Diagram 4-32 Figure 4-15 OC192 LR/STM64 LH 1550 (15454-OC192LR1550) Faceplate and Block Diagram Figure 4-16 Enlarged Section of the OC192 LR/STM64 LH 1550 (15454-OC192LR1550) Faceplate Figure 4-17 OC192 LR/STM64 LH 1550 (15454-OC192-LR2) Faceplate and Block Diagram Figure 4-18 Enlarged Section of the OC192 LR/STM64 LH 1550 (15454-OC192-LR2) Faceplate Figure 4-19 OC192 LR/STM64 LH ITU 15xx.xx Faceplate Figure 4-20 OC192 LR/STM64 LH ITU 15xx.xx Block Diagram Figure 4-21 15454_MRC-12 Card Faceplate and Block Diagram Figure 4-22 MRC-2.5G-4 Card Faceplate and Block Diagram Figure 4-23 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Card Faceplates and Block Diagram Figure 4-24 Mylar Tab SFP Figure 4-25 Actuator/Button SFP Figure 4-26 Bail Clasp SFP Figure 4-27 Bail Clasp XFP (Unlatched) Figure 4-28 Bail Clasp XFP (Latched) Figure 5-1 E100T-12 Faceplate and Block Diagram Figure 5-2 E100T-G Faceplate and Block Diagram 5-7 Figure 5-3 E1000-2 Faceplate and Block Diagram 5-9 Figure 5-4 E1000-2-G Faceplate and Block Diagram Figure 5-5 G1000-4 Faceplate and Block Diagram Figure 5-6 G1K-4 Faceplate and Block Diagram 3-31 4-16 4-26 4-28 4-34 4-35 4-36 4-37 4-39 4-40 4-42 4-47 4-51 4-54 4-54 4-54 4-55 4-55 5-5 5-12 5-14 5-17 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xxv Figures Figure 5-7 ML100T-12 Faceplate and Block Diagram Figure 5-8 ML100X-8 Faceplate and Block Diagram 5-22 Figure 5-9 ML1000-2 Faceplate and Block Diagram 5-24 Figure 5-10 ML-MR-10 Faceplate and Block Diagram 5-26 Figure 5-11 CE-100T-8 Faceplate and Block Diagram 5-29 Figure 5-12 CE-1000-4 Faceplate and Block Diagram 5-32 Figure 5-13 CE-MR-10 Faceplate and Block Diagram 5-35 Figure 5-14 GBICs with Clips (left) and with a Handle (right) Figure 5-15 CWDM GBIC with Wavelength Appropriate for Fiber-Connected Device Figure 5-16 G-Series with CWDM/DWDM GBICs in Cable Network Figure 5-17 Mylar Tab SFP Figure 5-18 Actuator/Button SFP Figure 5-19 Bail Clasp SFP Figure 6-1 FC_MR-4 Faceplate and Block Diagram Figure 7-1 Example: ONS 15454 Cards in a 1:1 Protection Configuration (SMB EIA) 7-2 Figure 7-2 Example: ONS 15454 Cards in a 1:N Protection Configuration (SMB EIA) 7-3 Figure 7-3 Unprotected Low-Density Electrical Card Schemes for EIA Types 7-7 Figure 7-4 Unprotected High-Density Electrical Card Schemes for EIA Types 7-8 Figure 7-5 1:1 Protection Schemes for Low-Density Electrical Cards with EIA Types 7-9 Figure 7-6 1:N Protection Schemes for Low-Density Electrical Cards with EIA Types 7-10 Figure 7-7 1:1 Protection Schemes for High-Density Electrical Cards with UBIC or MiniBNC EIA Types Figure 7-8 ONS 15454 in an Unprotected Configuration Figure 8-1 CTC Software Versions, Node View Figure 8-2 CTC Software Versions, Network View Figure 8-3 Node View (Default Login View) Figure 8-4 Terminal Loopback Indicator Figure 8-5 Facility Loopback Indicator Figure 8-6 Network in CTC Network View Figure 8-7 CTC Card View Showing a DS1 Card Figure 8-8 Static IP-Over-CLNS Tunnels Figure 8-9 TL1 Tunnels Figure 10-1 ONS 15454 Timing Example Figure 11-1 ONS 15454 Circuit Window in Network View Figure 11-2 BLSR Circuit Displayed on the Detailed Circuit Map Figure 11-3 One VT1.5 Circuit on One STS 5-20 5-39 5-40 5-41 5-41 5-42 5-42 6-3 7-11 7-14 8-2 8-3 8-9 8-11 8-11 8-13 8-16 8-19 8-20 10-3 11-4 11-12 11-13 Cisco ONS 15454 Reference Manual, R8.5.x xxvi 78-18106-01 Figures Figure 11-4 Two VT1.5 Circuits in a BLSR Figure 11-5 Traditional DCC Tunnel Figure 11-6 VT1.5 Monitor Circuit Received at an EC1-12 Port Figure 11-7 Editing Path Protection Selectors Figure 11-8 Path Protection Go-and-Return Routing Figure 11-9 Secondary Sources and Destinations Figure 11-10 Alternate Paths for Virtual Path Protection Segments Figure 11-11 Mixing 1+1 or BLSR Protected Links With a Path Protection Configuration Figure 11-12 Ethernet Shared Packet Ring Routing Figure 11-13 Ethernet and Path Protection 11-31 Figure 11-14 VCAT Common Fiber Routing 11-35 Figure 11-15 VCAT Split Fiber Routing Figure 11-16 Open-Ended VCAT Figure 11-17 Rolls Window Figure 11-18 Single Source Roll Figure 11-19 Single Destination Roll Figure 11-20 Single Roll from One Circuit to Another Circuit (Destination Changes) Figure 11-21 Single Roll from One Circuit to Another Circuit (Source Changes) Figure 11-22 Dual Roll to Reroute a Link Figure 11-23 Dual Roll to Reroute to a Different Node Figure 12-1 Four-Node, Two-Fiber BLSR Figure 12-2 Four-Node, Two-Fiber BLSR Traffic Pattern Sample Figure 12-3 Four-Node, Two-Fiber BLSR Traffic Pattern Following Line Break Figure 12-4 Four-Node, Four-Fiber BLSR Figure 12-5 Four-Fiber BLSR Span Switch 12-8 Figure 12-6 Four-Fiber BLSR Ring Switch 12-9 Figure 12-7 BLSR Bandwidth Reuse Figure 12-8 Five-Node Two-Fiber BLSR Figure 12-9 Shelf Assembly Layout for Node 0 in Figure 12-8 Figure 12-10 Shelf Assembly Layout for Nodes 1 to 4 in Figure 12-8 Figure 12-11 Connecting Fiber to a Four-Node, Two-Fiber BLSR 12-13 Figure 12-12 Connecting Fiber to a Four-Node, Four-Fiber BLSR 12-14 Figure 12-13 Basic Four-Node Path Protection Figure 12-14 Path Protection with a Fiber Break Figure 12-15 Four-Port, OC-3 Path Protection 11-14 11-17 11-19 11-20 11-21 11-29 11-30 11-30 11-31 11-35 11-39 11-41 11-43 11-43 11-44 11-44 11-45 11-45 12-4 12-5 12-6 12-7 12-10 12-11 12-12 12-12 12-15 12-16 12-17 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xxvii Figures Figure 12-16 Layout of Node ID 0 in the OC-3 Path Protection Example in Figure 12-15 Figure 12-17 Layout of Node IDs 1 to 3 in the OC-3 Path Protection Example in Figure 12-15 Figure 12-18 ONS 15454 Traditional BLSR Dual-Ring Interconnect (Same-Side Routing) Figure 12-19 ONS 15454 Traditional BLSR Dual-Ring Interconnect (Opposite-Side Routing) Figure 12-20 ONS 15454 Integrated BLSR Dual-Ring Interconnect Figure 12-21 Integrated BLSR DRI on the Edit Circuits Window Figure 12-22 ONS 15454 Traditional Path Protection Dual-Ring Interconnect 12-24 Figure 12-23 ONS 15454 Integrated Path Protection Dual-Ring Interconnect 12-25 Figure 12-24 ONS 15454 Path Protection to BLSR Traditional DRI Handoff 12-26 Figure 12-25 ONS 15454 Path Protection to BLSR Integrated DRI Handoff 12-27 Figure 12-26 Path Protection to BLSR Integrated DRI Handoff on the Detailed Circuit Map Figure 12-27 ONS 15454 with Multiple Subtending Rings Figure 12-28 Path Protection Subtending from a BLSR Figure 12-29 BLSR Subtending from a BLSR Figure 12-30 Linear (Point-to-Point) ADM Configuration Figure 12-31 Path-Protected Mesh Network Figure 12-32 PPMN Virtual Ring Figure 12-33 Four-Shelf Node Configuration Figure 12-34 STS Around the Ring Figure 12-35 Unprotected Point-to-Point ADM to Path Protection Conversion Figure 13-1 IP Scenario 1: CTC and ONS 15454s on Same Subnet Figure 13-2 IP Scenario 2: CTC and ONS 15454 Nodes Connected to a Router Figure 13-3 IP Scenario 3: Using Proxy ARP Figure 13-4 IP Scenario 3: Using Proxy ARP with Static Routing 13-6 Figure 13-5 IP Scenario 4: Default Gateway on a CTC Computer 13-7 Figure 13-6 IP Scenario 5: Static Route With One CTC Computer Used as a Destination Figure 13-7 IP Scenario 5: Static Route With Multiple LAN Destinations Figure 13-8 IP Scenario 6: OSPF Enabled Figure 13-9 IP Scenario 6: OSPF Not Enabled Figure 13-10 SOCKS Proxy Server Gateway Settings Figure 13-11 IP Scenario 7: ONS 15454 SOCKS Proxy Server with GNE and ENEs on the Same Subnet 13-15 Figure 13-12 IP Scenario 7: ONS 15454 SOCKS Proxy Server with GNE and ENEs on Different Subnets 13-16 Figure 13-13 IP Scenario 7: ONS 15454 SOCKS Proxy Server With ENEs on Multiple Rings Figure 13-14 IP Scenario 8: Dual GNEs on the Same Subnet 13-19 Figure 13-15 IP Scenario 8: Dual GNEs on Different Subnets 13-20 12-18 12-18 12-20 12-21 12-22 12-23 12-28 12-29 12-30 12-30 12-31 12-32 12-33 12-34 12-35 12-40 13-3 13-4 13-5 13-8 13-9 13-11 13-12 13-13 13-17 Cisco ONS 15454 Reference Manual, R8.5.x xxviii 78-18106-01 Figures Figure 13-16 IP Scenario 9: ONS 15454 GNE and ENEs on the Same Subnet with Secure Mode Enabled 13-22 Figure 13-17 IP Scenario 9: ONS 15454 GNE and ENEs on Different Subnets with Secure Mode Enabled 13-23 Figure 13-18 Proxy and Firewall Tunnels for Foreign Terminations Figure 13-19 Foreign Node Connection to an ENE Ethernet Port Figure 13-20 ISO-DCC NSAP Address Figure 13-21 OSI Main Setup Figure 13-22 Level 1 and Level 2 OSI Routing Figure 13-23 Manual TARP Adjacencies Figure 13-24 T–TD Protocol Flow Figure 13-25 FT–TD Protocol Flow Figure 13-26 Provisioning OSI Routers Figure 13-27 IP-over-CLNS Tunnel Flow Figure 13-28 IP-over-CLNS Tunnel Scenario 1: ONS NE to Other Vender GNE Figure 13-29 IP-over-CLNS Tunnel Scenario 2: ONS Node to Router Figure 13-30 IP-over-CLNS Tunnel Scenario 3: ONS Node to Router Across an OSI DCN Figure 13-31 OSI/IP Scenario 1: IP OSS, IP DCN, ONS GNE, IP DCC, and ONS ENE Figure 13-32 OSI/IP Scenario 2: IP OSS, IP DCN, ONS GNE, OSI DCC, and Other Vendor ENE 13-51 Figure 13-33 OSI/IP Scenario 3: IP OSS, IP DCN, Other Vendor GNE, OSI DCC, and ONS ENE 13-53 Figure 13-34 OSI/IP Scenario 3 with OSI/IP-over-CLNS Tunnel Endpoint at the GNE Figure 13-35 OSI/IP Scenario 4: Multiple ONS DCC Areas Figure 13-36 OSI/IP Scenario 5: GNE Without an OSI DCC Connection Figure 13-37 OSI/IP Scenario 6: IP OSS, OSI DCN, ONS GNE, OSI DCC, and Other Vendor ENE Figure 13-38 OSI/IP Scenario 7: OSI OSS, OSI DCN, Other Vender GNE, OSI DCC, and ONS NEs 13-58 Figure 13-39 OSI/IP Scenario 8: OSI OSS, OSI DCN, ONS GNE, OSI DCC, and Other Vender NEs 13-60 Figure 14-1 Shelf LCD Panel Figure 14-2 Select Affected Circuits Option Figure 14-3 Network View Alarm Profiles Window Figure 14-4 DS1 Card Alarm Profile 14-13 Figure 15-1 TCAs Displayed in CTC 15-2 Figure 15-2 Monitored Signal Types for the EC1-12 Card Figure 15-3 PM Read Points on the EC1-12 Card Figure 15-4 Monitored Signal Types for the DS1/E1-56 Card Figure 15-5 PM Read Points on the DS1/E1-56 Card Figure 15-6 Monitored Signal Types for the DS1-14 and DS1N-14 Cards Figure 15-7 PM Read Points on the DS1-14 and DS1N-14 Cards 13-28 13-29 13-33 13-34 13-35 13-40 13-41 13-41 13-42 13-44 13-46 13-47 13-49 13-50 13-54 13-55 13-56 13-57 14-2 14-5 14-10 15-12 15-13 15-14 15-15 15-16 15-17 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xxix Figures Figure 15-8 Monitored Signal Types for the DS3-12 and DS3N-12 Cards Figure 15-9 PM Read Points on the DS3-12 and DS3N-12 Cards Figure 15-10 Monitored Signal Types for the DS3-12E and DS3N-12E Cards Figure 15-11 PM Read Points on the DS3-12E and DS3N-12E Cards Figure 15-12 Monitored Signal Types for the DS3i-N-12 Cards Figure 15-13 PM Read Points on the DS3i-N-12 Cards Figure 15-14 Monitored Signal Types for the DS3XM-6 Card Figure 15-15 PM Read Points on the DS3XM-6 Card Figure 15-16 Monitored Signal Types for the DS3XM-12 Card Figure 15-17 PM Read Points on the DS3XM-12 Card Figure 15-18 Monitored Signal Types for the DS3/EC1-48 Card Figure 15-19 PM Read Points on the DS3/EC1-48 Card Figure 15-20 Monitored Signal Types for the OC-3 Cards Figure 15-21 PM Read Points on the OC-3 Cards Figure 15-22 PM Read Points for the MRC-12 and the MRC-2.5G-4 Cards Figure 16-1 Basic Network Managed by SNMP Figure 16-2 Example of the Primary SNMP Components Figure 16-3 Agent Gathering Data from a MIB and Sending Traps to the Manager 15-18 15-19 15-20 15-20 15-21 15-22 15-23 15-24 15-25 15-26 15-27 15-28 15-49 15-49 15-52 16-2 16-3 16-3 Cisco ONS 15454 Reference Manual, R8.5.x xxx 78-18106-01 T A B L E S Table 1-1 EIA Types Compatible with the 15454-SA-ANSI Only Table 1-2 EIA Configurations Compatible with the 15454-SA-ANSI and the 15454-SA-HD Table 1-3 MiniBNC Protection Types and Slots Table 1-4 J-Labeling Port Assignments for a Shelf Assembly Configure with Low-Density Electrical Cards (A Side) 1-24 Table 1-5 J-Labeling Port Assignments for a Shelf Assembly Configured with Low-Density Electrical Cards (B Side) 1-25 Table 1-6 J-Labeling Port Assignments for a Shelf Configured with High-Density Electrical Cards (A Side) 1-26 Table 1-7 J-Labeling Port Assignments for a Shelf Configured with High-Density Electrical Cards (B Side) 1-27 Table 1-8 AMP Champ Connector Pin Assignments Table 1-9 AMP Champ Connector Pin Assignments (Shielded DS-1 Cable) Table 1-10 UBIC-V Protection Types and Slots Table 1-11 J-Labeling Port Assignments for a Shelf Assembly Configured with Low-Density Electrical Cards (A Side) 1-36 Table 1-12 J-Labeling Port Assignments for a Shelf Assembly Configured with Low-Density Electrical Cards (B Side) 1-36 Table 1-13 J-Labeling Port Assignments for a Shelf Configured with High-Density Electrical Cards (A Side) 1-37 Table 1-14 J-Labeling Port Assignments for a Shelf Configured with High-Density Electrical Cards (B Side) 1-37 Table 1-15 UBIC-H Protection Types and Slots Table 1-16 UBIC-V DS-1 SCSI Connector Pin Out Table 1-17 UBIC-V DS-1 Tip/Ring Color Coding Table 1-18 UBIC-V DS-3/EC-1 SCSI Connector Pin Out Table 1-19 UBIC-H DS-1 SCSI Connector Pin Out Table 1-20 UBIC-H DS-1 Tip/Ring Color Coding Table 1-21 UBIC-H DS-3/EC-1 SCSI Connector Pin Out Table 1-22 E100-TX Connector Pinout Table 1-23 Fiber Channel Capacity (One Side of the Shelf) Table 1-24 Pin Assignments for the AEP Table 1-25 Alarm Input Pin Association Table 1-26 Pin Association for Alarm Output Pins Table 1-27 Fan Tray Units for ONS 15454 Cards Table 1-28 Pilot Fuse Ratings Table 1-29 BITS External Timing Pin Assignments Table 1-30 LAN Pin Assignments 1-16 1-17 1-22 1-31 1-31 1-34 1-38 1-41 1-43 1-43 1-47 1-49 1-49 1-52 1-55 1-58 1-59 1-60 1-63 1-66 1-70 1-71 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xxxi Tables Table 1-31 Craft Interface Pin Assignments Table 1-32 Slot and Card Symbols Table 1-33 Card Ports, Line Rates, and Connectors Table 1-34 ONS 15454 Software and Hardware Compatibility—XC and XCVT Configurations Table 1-35 ONS 15454 Software and Hardware Compatibility—XC10G and XC-VXC-10G Configurations Table 2-1 Common Control Card Functions Table 2-2 Common-Control Card Software Release Compatibility Table 2-3 Common-Control Card Cross-Connect Compatibility Table 2-4 Electrical Card Cross-Connect Compatibility Table 2-5 Optical Card Cross-Connect Compatibility Table 2-6 Ethernet Card Cross-Connect Compatibility Table 2-7 SAN Card Cross-Connect Compatibility Table 2-8 TCC2 Card-Level Indicators Table 2-9 TCC2 Power-Level Indicators 2-10 Table 2-10 TCC2P Card-Level Indicators 2-14 Table 2-11 TCC2P Network-Level Indicators Table 2-12 TCC2P Power-Level Indicators Table 2-13 VT Mapping Table 2-14 XCVT Card-Level Indicators Table 2-15 VT Mapping Table 2-16 XC10G Card-Level Indicators Table 2-17 VT Mapping Table 2-18 XC-VXC-10G Card-Level Indicators Table 2-19 AIC-I Card-Level Indicators 2-29 Table 2-20 Orderwire Pin Assignments 2-32 Table 2-21 UDC Pin Assignments 2-33 Table 2-22 DCC Pin Assignments 2-33 Table 3-1 Cisco ONS 15454 Electrical Cards Table 3-2 Electrical Card Software Release Compatibility Table 3-3 Enabling BERT on Line Side and Backplane Side Table 3-4 EC1-12 Card-Level Indicators Table 3-5 DS1-14 and DS1N-14 Card-Level Indicators Table 3-6 DS1/E1-56 Slot Restrictions Table 3-7 DS1/E1-56 Card-Level Indicators Table 3-8 DS3-12 and DS3N-12 Card-Level Indicators 1-71 1-73 1-73 1-76 1-79 2-2 2-3 2-3 2-4 2-4 2-5 2-6 2-9 2-14 2-15 2-17 2-19 2-21 2-22 2-26 2-27 3-2 3-3 3-4 3-7 3-10 3-11 3-13 3-15 Cisco ONS 15454 Reference Manual, R8.5.x xxxii 78-18106-01 Tables Table 3-9 DS3/EC1-48 Slot Restrictions Table 3-10 DS3/EC1-48 Card-Level Indicators Table 3-11 DS3i-N-12 Card-Level Indicators Table 3-12 DS3-12E and DS3N-12E Card-Level Indicators Table 3-13 DS3XM-6 Card-Level Indicators 3-27 Table 3-14 DS3XM-12 Shelf Configurations 3-28 Table 3-15 DS3XM-12 Features Table 3-16 DS3XM-12 Card-Level Indicators 3-32 Table 4-1 Optical Cards for the ONS 15454 4-2 Table 4-2 Optical Card Software Release Compatibility Table 4-3 OC3 IR 4/STM1 SH 1310 Card-Level Indicators 4-7 Table 4-4 OC3IR/STM1 SH 1310-8 Card-Level Indicators 4-9 Table 4-5 OC12 IR/STM4 SH 1310 Card-Level Indicators 4-11 Table 4-6 OC12 LR/STM4 LH 1310 Card-Level Indicators 4-13 Table 4-7 OC12 LR/STM4 LH 1550 Card-Level Indicators 4-15 Table 4-8 OC12 IR/STM4 SH 1310-4 Card-Level Indicators Table 4-9 OC48 IR 1310 Card-Level Indicators 4-19 Table 4-10 OC48 LR 1550 Card-Level Indicators 4-21 Table 4-11 OC48 IR/STM16 SH AS 1310 Card-Level Indicators 4-23 Table 4-12 OC48 LR/STM16 LH AS 1550 Card-Level Indicators 4-25 Table 4-13 OC48 ELR/STM16 EH 100 GHz Card-Level Indicators Table 4-14 OC48 ELR 200 GHz Card-Level Indicators Table 4-15 OC192 SR/STM64 IO 1310 Card-Level Indicators 4-31 Table 4-16 OC192 IR/STM64 SH 1550 Card-Level Indicators 4-33 Table 4-17 OC192 LR/STM64 LH 1550 Card-Level Indicators 4-38 Table 4-18 OC192 LR/STM64 LH ITU 15xx.xx Card-Level Indicators Table 4-19 Maximum Bandwidth by Shelf Slot for the 15454_MRC-12 in Different Cross-Connect Configurations Table 4-20 Line Rate Configurations Per 15454_MRC-12 Port, Based on Available Bandwidth Table 4-21 15454_MRC-12 Card-Level Indicators Table 4-22 Maximum Bandwidth by Shelf Slot for the MRC-2.5G-4 in Different Cross-Connect Configurations Table 4-23 Line Rate Configurations Per 15454_MRC- 4 Port, Based on Available Bandwidth Table 4-24 MRC-2.5G-4 Card-Level Indicators Table 4-25 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Card-Level Indicators Table 4-26 SFP and XFP Card Compatibility Table 4-27 LED Based SFPs 3-16 3-19 3-21 3-24 3-29 4-5 4-17 4-27 4-29 4-41 4-43 4-44 4-46 4-48 4-49 4-49 4-52 4-53 4-54 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xxxiii Tables Table 5-1 Ethernet Cards for the ONS 15454 Table 5-2 Ethernet Card Software Compatibility Table 5-3 E100T-12 Card-Level Indicators 5-6 Table 5-4 E100T-12 Port-Level Indicators 5-6 Table 5-5 E100T-G Card-Level Indicators 5-8 Table 5-6 E100T-G Port-Level Indicators 5-8 Table 5-7 E1000-2 Card-Level Indicators 5-10 Table 5-8 E1000-2 Port-Level Indicators 5-11 Table 5-9 E1000-2-G Card-Level Indicators 5-13 Table 5-10 E1000-2-G Port-Level Indicators 5-13 Table 5-11 G1000-4 Card-Level Indicators 5-15 Table 5-12 G1000-4 Port-Level Indicators 5-16 Table 5-13 G1K-4 Card-Level Indicators 5-18 Table 5-14 G1K-4 Port-Level Indicators 5-18 Table 5-15 ML100T-12 Card-Level Indicators 5-21 Table 5-16 ML100T-12 Port-Level Indicators 5-21 Table 5-17 ML100X-8 Card-Level Indicators 5-23 Table 5-18 ML100X-8 Port-Level Indicators 5-23 Table 5-19 ML1000-2 Card-Level Indicators 5-25 Table 5-20 ML1000-2 Port-Level Indicators 5-25 Table 5-21 ML-MR-10 Card-Level Indicators 5-27 Table 5-22 ML-MR-10 Port-Level Indicators 5-27 Table 5-23 CE-100T-8 Card-Level Indicators 5-30 Table 5-24 CE-100T-8 Port-Level Indicators 5-30 Table 5-25 CE-1000-4 Card-Level Indicators 5-33 Table 5-26 CE-1000-4 Port-Level Indicators 5-33 Table 5-27 CE-MR-10 Card-Level Indicators 5-36 Table 5-28 CE-MR-10 Port-Level Indicators 5-36 Table 5-29 Available GBICs Table 5-30 Available SFPs and XFPs Table 5-31 Supported Wavelengths for CWDM GBICs 5-39 Table 5-32 Supported Wavelengths for DWDM GBICs 5-40 Table 6-1 FC_MR-4 Card-Level Indicators Table 6-2 GBIC Compatibility Table 7-1 Supported 1:1 Protection by Electrical Card 5-2 5-3 5-37 5-37 6-3 6-8 7-2 Cisco ONS 15454 Reference Manual, R8.5.x xxxiv 78-18106-01 Tables Table 7-2 Supported 1:N Protection by Electrical Card Table 7-3 EIA Connectors Per Side Table 7-4 Electrical Card Protection By EIA Type Table 8-1 JRE Compatibility Table 8-2 Computer Requirements for CTC 8-5 Table 8-3 ONS 15454 Connection Methods 8-7 Table 8-4 Node View Card Colors Table 8-5 Node View Card Statuses Table 8-6 Node View Card Port Colors and Service States Table 8-7 Node View Tabs and Subtabs Table 8-8 Network View Tabs and Subtabs Table 8-9 Node Status Shown in Network View Table 8-10 DCC Colors Indicating State in Network View Table 8-11 Link Icons Table 8-12 Card View Tabs and Subtabs Table 8-13 TL1 and Static IP-Over-CLNS Tunnels Comparison Table 9-1 ONS 15454 Security Levels—Node View Table 9-2 ONS 15454 Security Levels—Network View Table 9-3 ONS 15454 Default User Idle Times Table 9-4 Audit Trail Window Columns Table 9-5 Shared Secret Character Groups Table 10-1 SONET SSM Generation 1 Message Set 10-4 Table 10-2 SONET SSM Generation 2 Message Set 10-4 Table 10-3 SDH SSM Messages Table 11-1 STS Mapping Using CTC Table 11-2 ONS 15454 Circuit Status Table 11-3 Circuit Protection Types Table 11-4 Port State Color Indicators Table 11-5 VT Matrix Port Usage for One VT1.5 Circuit Table 11-6 Portless Transmux Mapping for XCVT Drop Ports Table 11-7 Portless Transmux Mapping for XCVT Trunk and XC10G/XC-VXC-10G Any-Slot Ports Table 11-8 DCC Tunnels Table 11-9 ONS 15454 Cards Capable of J1 Path Trace Table 11-10 STS Path Signal Label Assignments for Signals Table 11-11 STS Path Signal Label Assignments for Signals with Payload Defects 7-3 7-5 7-6 8-5 8-9 8-10 8-10 8-11 8-13 8-14 8-14 8-15 8-16 8-20 9-2 9-5 9-7 9-8 9-10 10-4 11-4 11-6 11-9 11-11 11-15 11-16 11-16 11-17 11-25 11-26 11-26 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xxxv Tables Table 11-12 Bidirectional STS/VT/Regular Multicard EtherSwitch/Point-to-Point (Straight) Ethernet Circuits Table 11-13 Unidirectional STS/VT Circuit Table 11-14 Multicard Group Ethernet Shared Packet Ring Circuit Table 11-15 Bidirectional VT Tunnels Table 11-16 Switch Times Table 11-17 ONS 15454 Card VCAT Circuit Rates and Members Table 11-18 ONS 15454 VCAT Card Capabilities Table 11-19 Protection options for Open-Ended VCAT Circuits Table 11-20 Roll Statuses Table 12-1 ONS 15454 Rings with Redundant TCC2/TCC2P Cards Table 12-2 Two-Fiber BLSR Capacity 12-9 Table 12-3 Four-Fiber BLSR Capacity 12-10 Table 12-4 Comparison of the Protection Schemes Table 12-5 Slot 5, 6, 12, and 13 Upgrade Options Table 12-6 Upgrade Options for Slots 1 through 4 and 14 through 17 Table 13-1 General ONS 15454 IP Troubleshooting Checklist Table 13-2 ONS 15454 Gateway and End NE Settings Table 13-3 SOCKS Proxy Server Firewall Filtering Rules Table 13-4 SOCKS Proxy Server Firewall Filtering Rules When Packet Addressed to the ONS 15454 Table 13-5 Sample Routing Table Entries Table 13-6 Ports Used by the TCC2/TCC2P Table 13-7 TCP/IP and OSI Protocols Table 13-8 NSAP Fields Table 13-9 TARP PDU Fields 13-37 Table 13-10 TARP PDU Types 13-37 Table 13-11 TARP Timers Table 13-12 TARP Processing Flow Table 13-13 OSI Virtual Router Constraints Table 13-14 IP-over-CLNS Tunnel IOS Commands Table 13-15 OSI Actions from the CTC Provisioning Tab Table 13-16 OSI Actions from the CTC Maintenance Tab Table 14-1 Alarms Column Descriptions Table 14-2 Color Codes for Alarm and Condition Severities Table 14-3 Alarm Display Table 14-4 Conditions Display 11-31 11-32 11-32 11-32 11-36 11-37 11-38 11-39 11-42 12-2 12-28 12-36 12-37 13-2 13-15 13-17 13-18 13-24 13-25 13-30 13-32 13-38 13-39 13-43 13-45 13-61 13-61 14-2 14-3 14-4 14-6 Cisco ONS 15454 Reference Manual, R8.5.x xxxvi 78-18106-01 Tables Table 14-5 Conditions Column Description Table 14-6 History Column Description Table 14-7 Alarm Profile Buttons Table 14-8 Alarm Profile Editing Options Table 15-1 Electrical Cards that Report RX and TX Direction for TCAs Table 15-2 ONS 15454 Line Terminating Equipment Table 15-3 Performance Monitoring Parameters Table 15-4 EC1-12 Card PMs Table 15-5 DS1/E1-56 Card PMs Table 15-6 DS1-14 and DS1N-14 Card PMs 15-17 Table 15-7 DS3-12 and DS3N-12 Card PMs 15-19 Table 15-8 DS3-12E and DS3N-12E Card PMs Table 15-9 DS3i-N-12 Card PMs Table 15-10 DS3XM-6 Card PMs Table 15-11 DS3XM-12 Card PMs Table 15-12 DS3/EC1-48 Card PMs Table 15-13 E-Series Ethernet Statistics Parameters Table 15-14 maxBaseRate for STS Circuits Table 15-15 Ethernet History Statistics per Time Interval Table 15-16 G-Series Ethernet Statistics Parameters Table 15-17 ML-Series Ether Ports PM Parameters Table 15-18 ML-Series POS Ports Parameters for HDLC Mode 15-37 Table 15-19 ML-Series POS Ports Parameters for GFP-F Mode 15-38 Table 15-20 ML-Series RPR Span Parameters for 802.17 MIB Table 15-21 CE-Series Ether Port PM Parameters Table 15-22 CE-Series Card POS Ports Parameters Table 15-23 OC-3 Card PMs Table 15-24 OC3-8 Card PMs Table 15-25 OC-12, OC-48, OC-192, OC-192-XFP Card PMs Table 15-26 Table of Border Error Rates Table 15-27 MRC Card PMs Table 15-28 FC_MR-4 Statistics Window 14-6 14-8 14-11 14-12 15-3 15-3 15-5 15-13 15-16 15-21 15-22 15-24 15-26 15-28 15-29 15-31 15-31 15-32 15-34 15-38 15-44 15-47 15-50 15-50 15-51 15-51 15-52 15-53 Table 15-29 maxBaseRate for STS Circuits Table 15-30 FC_MR-4 History Statistics per Time Interval Table 16-1 ONS 15454 SNMP Message Types 15-54 15-55 16-4 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xxxvii Tables Table 16-2 IETF Standard MIBs Implemented in the ONS 15454 System Table 16-3 ONS 15454 Proprietary MIBs Table 16-4 cerentGenericPmThresholdTable Table 16-5 32-Bit cerentGenericPmStatsCurrentTable 16-8 Table 16-6 32-Bit cerentGenericPmStatsIntervalTable 16-8 Table 16-7 Supported Generic IETF Traps Table 16-8 Supported ONS 15454 SNMPv2 Trap Variable Bindings Table 16-9 RMON History Control Periods and History Categories Table 16-10 OIDs Supported in the AlarmTable Table A-1 Fan Tray Assembly Power Requirements Table A-2 SFP, XFP, and GBIC Specifications Table A-3 Individual Card Power Requirements Table A-4 Card Temperature Ranges and Product Names Table B-1 ONS 15454 Service State Primary States and Primary State Qualifiers Table B-2 ONS 15454 Secondary States Table B-3 ONS 15454 Administrative States Table B-4 ONS 15454 Card Service State Transitions Table B-5 ONS 15454 Port and Cross-Connect Service State Transitions Table B-6 ONS 15454 Pluggable Equipment Service State Transitions Table C-1 DS-1 Card Default Settings Table C-2 DS1/E1-56 Card Default Settings Table C-3 DS-3 Card Default Settings Table C-4 DS3/EC1-48 Card Default Settings Table C-5 DS3E Card Default Settings C-19 Table C-6 DS3I Card Default Settings C-22 Table C-7 DS3XM-6 Card Default Settings Table C-8 DS3XM-12 Card Default Settings Table C-9 EC1-12 Card Default Settings Table C-10 FC_MR-4 Card Default Settings Table C-11 Ethernet Card Default Settings Table C-12 OC-3 Card Default Settings Table C-13 OC3-8 Card Default Settings C-38 Table C-14 OC-12 Card Default Settings C-42 Table C-15 OC12-4 Card Default Settings Table C-16 OC-48 Card Default Settings 16-5 16-6 16-7 16-9 16-10 16-19 16-21 A-4 A-5 A-8 A-10 B-1 B-2 B-3 B-3 B-6 B-10 C-4 C-7 C-13 C-14 C-24 C-26 C-30 C-33 C-34 C-35 C-45 C-49 Cisco ONS 15454 Reference Manual, R8.5.x xxxviii 78-18106-01 Tables Table C-17 OC-192 Card Default Settings Table C-18 OC192-XFP Default Settings Table C-19 MRC-12 Card Default Settings Table C-20 MRC-2.5G-4 Card Default Settings Table C-21 Node Default Settings Table C-22 Time Zones Table C-23 CTC Default Settings C-54 C-59 C-65 C-82 C-101 C-118 C-121 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xxxix Tables Cisco ONS 15454 Reference Manual, R8.5.x xl 78-18106-01 About this Manual Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This section explains the objectives, intended audience, and organization of this publication and describes the conventions that convey instructions and other information. This section provides the following information: • Document Objectives • Audience • Related Documentation • Document Conventions • Obtaining Optical Networking Information • Obtaining Documentation and Submitting a Service Request Revision History Date Notes September 2007 Added this Revision History table. Incorporated the NEBS Compliance changes in Appendix-A A1.11 System Power section. August 2007 • Updated Performance Monitoring chapterwith information about border error rates. • Updated the default value for DS3XM12.config.FeInhibitLpbk in the Network Element Defaults chapter. • Added sub-section 11.22.1, VCAT Circuit Routing over Server Trails. • Added high switch information about DS3XM12 cards having different backplane bandwidths in section 3.10.5 Protection Modes. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xli About this Manual Date Notes November 2007 Updated 1+1 Protection section in Card Protection chapter. Updated Shelf Configurations section in Electrical Cards chapter. January 2008 Updated cabling details for ONS-SE-ZE-EL SFP. February 2008 March 2008 April 2008 May 2008 • Removed the line stating support for XCVT card in the Cross Connect and Slot Compatability subsection under the ML100X-8 Card section in the Ethernet Cards chapter. • Updated the Computer Requirements for CTC table in Cisco Transport Controller Operation chapter. • Updated the Software and Hardware Compatibility—XC and XCVT Configurations table to show OC48 IR 1310 as Not Supported under R8.0.0x column in the Shelf and Backplane Hardware chapter. Removed SFP ONS-SI-622-I1-MM= and added SFPs ONS-SI-155-SR-MM= and ONS-SI-622-SR-MM= in the following: • Optical Cards chapter • Hardware Specifications appendix • Corrected the Transmitter Output Power Min/Max for ONS-SI-155-SR-MM= and ONS-SI-622-SR-MM=. • Added a note in the User Password, Login, and Access Policies section in the Security chapter. • Created a new table to describe the Line Rate Configurations Per 15454_MRC-4 Port, Based on Available Bandwidth for 15454 MRC-4 Card matrix in Ports and Lines Rates section in Optical Cards chapter. • Updated the Software and Hardware Compatibility—XC and XCVT Configurations table to show OC192SR1/STM64IO Short Reach/ OC192/STM64 Any Reach as Fully compatible for all the releases in the Shelf and Backplane Hardware chapter. • Updated note on protection switching in Link Capacity Adjustment section of Circuits and Tunnels chapter. • Added a note in the TCC2P Functionality section, in Common Control Card chapter, to mention that 6.312-MHz BITS OUT functionality is supported in the TCC2P card and that the software support will be added in a future release. • Added a table and a note in the VCAT Member Routing section in the Circuits and Tunnels chapter. • Added a new section Speed-Duplex Combinations on SFPs under section SFP Modules in the Ethernet Cards chapter. • Added power-level LED information for TCC2 and TCC2P cards in Common Control Cards chapter. • Added note on DS3-12 card in the Card Compatibility section of Electrical Cards chapter. • Added a new section, Interoperability Rules for Electrical Cards in Electrical Cards chapter. Cisco ONS 15454 Reference Manual, R8.5.x xlii 78-18106-01 About this Manual Date July 2008 August 2008 September 2008 November 2008 December 2008 January 2009 February 2009 March 2009 April 2009 May 2009 Notes • Updated the 15454_MRC-12 Port-Level Indicators section, in the Optical Cards chapter to show the correct number and status of the Rx indicator. • Updated the MRC-2.5G-4 Port-Level Indicators section, in the Optical Cards chapter to show the correct number and status of the Rx indicator. • Added DS-3/EC1-48 card support for the EIA type MiniBNC in Table 1-2, Chapter 1, Shelf and Backplane Hardware. • Deleted the note in the Power and Ground Description section of Chapter 1, Shelf and Backplane Hardware. • Added a note in section 10.1 “Timing Parameters” of Chapter 10, Timing. Updated the RPR details for the ML-MR-10 card in section 5.11 ML-MR-10 Card of Chapter 5, Ethernet Cards. • Added a note in Card Default Settings and Node Default Settings section of Appendix C, Network Element Defaults. • Added a Warning for all optical cards in Chapter 4, Optical Cards. • Updated FC_MR-4 Statistics Parameters table in the Chapter 15, Performance Monitoring. • Updated the list of PM parameters for MRC-12 and MRC-4 cards in Chapter 15, Performance Monitoring. • Updated Server Trails section in Chapter 11, Circuits and Tunnels. • Updated the section “Compatibility by Card” in the chapter, “Optical Cards”. Updated the UBIC-V and UBIC-H sections in Chapter 1, Shelf and Backplane Hardware. • Updated the sub-section “EIA Configurations, Table 1-1 and 1-2” in Chapter 1, Shelf and Backplane Hardware. • Updated the SFP and XFP Card Compatibility table in Chapter 4, Optical Cards. Updated 1+1 Protection section in Chapter 7 Card Protection. • Added a note in section CE-MR-10 Card of Chapter 5, Ethernet Cards. • Updated Table 1-17 and Table 1-20 in UBIC-V and UBIC-H sections in Chapter 1, Shelf and Backplane Hardware. • Updated the SFP, XFP, and GBIC Specifications table in Appendix A. • Updated section DS1/E1-56 Card Specifications in Appendix A Hardware Specifications. • Updated MRC-2.5G-4 upgrade information in OC-N Speed Upgrades section in Chapter 12, Sonet Topologies and Upgrades. • Updated the User Password, Login, and Access Policies section in Chapter 9, Security. • Updated Table 12-4 and Table 12-5 to indicate support of span upgrades on MRC-12 and MRC-2.5G-4 cards to OC-192 or OC192-XFP in Chapter 12, Sonet Topologies and Upgrades. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xliii About this Manual Date Notes • Updated the Figure AEP Wire-Wrap Connections to Backplane Pins in Chapter 1, Shelf and Backplane Hardware. • Updated the 1.17.1 Card Slot Requirements section in Chapter 1, Shelf and Backplane Hardware. • Updated “OC-N Speed Upgrades” in Chapter 12, SONET Topologies and Upgrades. • Updated Table 1-2 in Chapter 1, Shelf and Backplane Hardware. • Updated the “Common-Control Card Software Release Compatibility” table in the chapter 2, Common Control Cards. • Added a new section, Comparison of the Protection Schemes in the chapter, SONET Topologies and Upgrades. • Updated the first footnote in the table titled ONS 15454 Software and Hardware Compatibility—XC10G and XC-VXC-10G Configurations in the chapter, Shelf and Backplane Hardware. • Updated the Line Rate Configurations Per 15454_MRC- 4 Port table in Chapter 4, Optical Cards. • Added a caution in section DS3XM-12 Card of Chapter 3, Electrical Cards. October 2009 • Updated the size of the MiniBNC Insertion and Removal Tool to RT-4L. November 2009 • Added a new section, SDH Tunneling in the chapter, Circuits and Tunnels. • Updated the table “Line Rate Configurations Per 15454_MRC-12 Port, Based on Available Bandwidth” in the chapter, “Optical Cards”. June 2009 July 2009 August 2009 January 2010 Updated the section “OC-N Speed Upgrades” in the chapter SONET Topologies and Upgrades. February 2010 Updated the table “SFP, XFP, and GBIC Specifications” in the appendix Hardware Specifications. April 2010 • Updated the section “SNMP Overview” in the chapter “SNMP”. • Created a section “Fan Tray Units for ONS 15454 Cards” in the chapter “Shelf and Backplane Hardware”. • Added footnote and note for ONS-SC-2G-28.7 SFP in the chapter “Optical Cards” and appendix “Hardware Specifications”. May 2010 Updated the note in the section “DS3/EC1-48 Card” in the chapter “Electrical Cards”. June 2010 Updated the caution in the section “DS1/E1-56 Card” in the chapter “Electrical Cards”. Document Objectives This manual provides reference information for the Cisco ONS 15454. Cisco ONS 15454 Reference Manual, R8.5.x xliv 78-18106-01 About this Manual Audience To use this publication, you should be familiar with Cisco or equivalent optical transmission hardware and cabling, telecommunications hardware and cabling, electronic circuitry and wiring practices, and preferably have experience as a telecommunications technician. Related Documentation Use the Cisco ONS 15454 Reference Manual with the following referenced publications: • Cisco ONS 15454 Procedure Guide Provides procedures to install, turn up, provision, and maintain a Cisco ONS 15454 node and network. • Cisco ONS 15454 Troubleshooting Guide Provides general troubleshooting procedures, alarm descriptions and troubleshooting procedures, error messages, and transient conditions. • Cisco ONS SONET TL1 Command Guide Provides a full TL1 command and autonomous message set including parameters, AIDs, conditions and modifiers for the Cisco ONS 15454, ONS 15600, ONS 15310-CL, and ONS 15310-MA systems. • Cisco ONS SONET TL1 Reference Guide Provides general information, procedures, and errors for TL1 in the Cisco ONS 15454, ONS 15600, ONS 15310-CL, and ONS 15310-MA systems. • Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration G uide Provides software features for all Ethernet cards and configuration information for Cisco IOS on ML-Series cards. • Release Notes for the Cisco ONS 15454 Release 8.5 Provides caveats, closed issues, and new feature and functionality information. For an update on End-of-Life and End-of-Sale notices, refer to http://cisco.com/en/US/products/hw/optical/ps2006/prod_eol_notices_list.html. Document Conventions This publication uses the following conventions: Convention Application boldface Commands and keywords in body text. italic Command input that is supplied by the user. [ Keywords or arguments that appear within square brackets are optional. ] {x|x|x} A choice of keywords (represented by x) appears in braces separated by vertical bars. The user must select one. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xlv About this Manual Convention Application Ctrl The control key. For example, where Ctrl + D is written, hold down the Control key while pressing the D key. screen font Examples of information displayed on the screen. boldface screen font Examples of information that the user must enter. < Command parameters that must be replaced by module-specific codes. > Note Means reader take note. Notes contain helpful suggestions or references to material not covered in the document. Caution Means reader be careful. In this situation, the user might do something that could result in equipment damage or loss of data. Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS Waarschuwing BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt raadplegen. BEWAAR DEZE INSTRUCTIES Varoitus TÄRKEITÄ TURVALLISUUSOHJEITA Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla. SÄILYTÄ NÄMÄ OHJEET Cisco ONS 15454 Reference Manual, R8.5.x xlvi 78-18106-01 About this Manual Attention IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil, référez-vous au numéro de l'instruction situé à la fin de chaque avertissement. CONSERVEZ CES INFORMATIONS Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden. BEWAHREN SIE DIESE HINWEISE GUT AUF. Avvertenza IMPORTANTI ISTRUZIONI SULLA SICUREZZA Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti. Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le traduzioni delle avvertenze riportate in questo documento. CONSERVARE QUESTE ISTRUZIONI Advarsel VIKTIGE SIKKERHETSINSTRUKSJONER Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade på person. Før du begynner å arbeide med noe av utstyret, må du være oppmerksom på farene forbundet med elektriske kretser, og kjenne til standardprosedyrer for å forhindre ulykker. Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten. TA VARE PÅ DISSE INSTRUKSJONENE Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Você está em uma situação que poderá ser causadora de lesões corporais. Antes de iniciar a utilização de qualquer equipamento, tenha conhecimento dos perigos envolvidos no manuseio de circuitos elétricos e familiarize-se com as práticas habituais de prevenção de acidentes. Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo. GUARDE ESTAS INSTRUÇÕES Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xlvii About this Manual ¡Advertencia! INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los procedimientos estándar de prevención de accidentes. Al final de cada advertencia encontrará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo. GUARDE ESTAS INSTRUCCIONES Varning! VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning. SPARA DESSA ANVISNINGAR Cisco ONS 15454 Reference Manual, R8.5.x xlviii 78-18106-01 About this Manual Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo. GUARDE ESTAS INSTRUÇÕES Advarsel VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for legemesbeskadigelse. Før du begynder arbejde på udstyr, skal du være opmærksom på de involverede risici, der er ved elektriske kredsløb, og du skal sætte dig ind i standardprocedurer til undgåelse af ulykker. Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler, der fulgte med denne enhed. GEM DISSE ANVISNINGER Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 xlix About this Manual Cisco ONS 15454 Reference Manual, R8.5.x l 78-18106-01 About this Manual Obtaining Optical Networking Information This section contains information that is specific to optical networking products. For information that pertains to all of Cisco, refer to the Obtaining Documentation and Submitting a Service Request section. Where to Find Safety and Warning Information For safety and warning information, refer to the Cisco Optical Transport Products Safety and Compliance Information document that accompanied the product. This publication describes the international agency compliance and safety information for the Cisco ONS 15454 system. It also includes translations of the safety warnings that appear in the ONS 15454 system documentation. Cisco Optical Networking Product Documentation CD-ROM Optical networking-related documentation, including Cisco ONS 15xxx product documentation, is available in a CD-ROM package that ships with your product. The Optical Networking Product Documentation CD-ROM is updated periodically and may be more current than printed documentation. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 li About this Manual Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0. Cisco ONS 15454 Reference Manual, R8.5.x lii 78-18106-01 CH A P T E R 1 Shelf and Backplane Hardware Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This chapter provides a description of Cisco ONS 15454 shelf and backplane hardware. Card descriptions are provided in Chapter 2, “Common Control Cards,” Chapter 3, “Electrical Cards,” Chapter 4, “Optical Cards,” Chapter 5, “Ethernet Cards,” and Chapter 6, “Storage Access Networking Cards.” To install equipment, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 1.1 Overview, page 1-2 • 1.2 Rack Installation, page 1-3 • 1.3 Front Door, page 1-6 • 1.4 Backplane Covers, page 1-11 • 1.5 Electrical Interface Assemblies, page 1-15 • 1.6 Coaxial Cable, page 1-38 • 1.7 DS-1 Cable, page 1-38 • 1.8 UBIC-V Cables, page 1-40 • 1.9 UBIC-H Cables, page 1-45 • 1.11 Cable Routing and Management, page 1-53 • 1.12 Alarm Expansion Panel, page 1-56 • 1.13 Filler Card, page 1-61 • 1.14 Fan-Tray Assembly, page 1-62 • 1.15 Power and Ground Description, page 1-66 • 1.16 Alarm, Timing, LAN, and Craft Pin Connections, page 1-67 • 1.17 Cards and Slots, page 1-71 • 1.18 Software and Hardware Compatibility, page 1-76 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-1 Chapter 1 Shelf and Backplane Hardware 1.1 Overview Caution Unused card slots should be filled with a detectable filler card (Cisco P/N 15454-FILLER) or a non-detectable filler card (Cisco P/N 15454-BLANK). The filler card ensures proper airflow when operating the ONS 15454 without the front door attached, although Cisco recommends that the front door remain attached. Note The ONS 15454 is designed to comply with Telcordia GR-1089-CORE Type 2 and Type 4. Install and operate the ONS 15454 only in environments that do not expose wiring or cabling to the outside plant. Acceptable applications include Central Office Environments (COEs), Electronic Equipment Enclosures (EEEs), Controlled Environment Vaults (CEVs), huts, and Customer Premise Environments (CPEs). Note The Cisco ONS 15454 assembly is intended for use with telecommunications equipment only. Note You can search for cross-referenced Cisco part numbers and CLEI (Common Language Equipment Identification) codes at the following link: http://www.cisco.com/cgi-bin/front.x/clei/code_search.cgi. 1.1 Overview When installed in an equipment rack, the ONS 15454 assembly is typically connected to a fuse and alarm panel to provide centralized alarm connection points and distributed power for the ONS 15454. Fuse and alarm panels are third-party equipment and are not described in this documentation. If you are unsure about the requirements or specifications for a fuse and alarm panel, consult the user documentation for the related equipment. The front door of the ONS 15454 allows access to the shelf assembly, fan-tray assembly, and cable-management area. The backplanes provide access to alarm contacts, external interface contacts, power terminals, and BNC/SMB connectors. You can mount the ONS 15454 in a 19- or 23-inch rack (482.6 or 584.2 mm). The shelf assembly weighs approximately 55 pounds (24.94 kg) with no cards installed. The shelf assembly includes a front door for added security, a fan tray module for cooling, and extensive cable-management space. ONS 15454 optical cards have SC and LC connectors on the card faceplate. Fiber-optic cables are routed into the front of the destination cards. Electrical cards (DS-1, DS-3, DS3XM, and EC-1) require electrical interface assemblies (EIAs) to provide the cable connection points for the shelf assembly. In most cases, EIAs are ordered with the ONS 15454 and come preinstalled on the backplane. See the “1.5 Electrical Interface Assemblies” section on page 1-15 for more information about the EIAs. The ONS 15454 is powered using –48 VDC power. Negative, return, and ground power terminals are accessible on the backplane. Note In this chapter, the terms “ONS 15454” and “shelf assembly” are used interchangeably. In the installation context, these terms have the same meaning. Otherwise, shelf assembly refers to the physical steel enclosure that holds cards and connects power, and ONS 15454 refers to the entire system, both hardware and software. Install the ONS 15454 in compliance with your local and national electrical codes: Cisco ONS 15454 Reference Manual, R8.5.x 1-2 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.2 Rack Installation • United States: National Fire Protection Association (NFPA) 70; United States National Electrical Code • Canada: Canadian Electrical Code, Part I, CSA C22.1 • Other countries: If local and national electrical codes are not available refer to IEC 364, Part 1 through Part 7 1.2 Rack Installation The ONS 15454 is mounted in a 19- or 23-in. (482.6- or 584.2-mm) equipment rack. The shelf assembly projects five inches (127 mm) from the front of the rack. It mounts in both Electronic Industries Alliance (EIA) standard and Telcordia-standard racks. The shelf assembly is a total of 17 inches (431.8 mm) wide with no mounting ears attached. Ring runs are not provided by Cisco and might hinder side-by-side installation of shelves where space is limited. The ONS 15454 measures 18.25 inches (463.5 mm) high, 19 or 23 inches (482.6 or 584.2 mm) wide (depending on which way the mounting ears are attached), 12.018 inches (305.2 mm) deep for standard door and 13.810 inches (350.7 mm) for deep door. You can install up to four ONS 15454 shelves in a seven-foot (2133.6 mm) equipment rack. The ONS 15454 must have one inch (25.4 mm) of airspace below the installed shelf assembly to allow air flow to the fan intake. If a second ONS 15454 is installed underneath the shelf assembly, the air ramp on top of the lower shelf assembly provides the air spacing needed and should not be modified in any way. Figure 1-1 shows the dimensions of the ONS 15454. Note A 10-Gbps-compatible shelf assembly (15454-SA-ANSI or 15454-SA-HD) and fan-tray assembly (15454-FTA3, 15454-FTA3-T, or 15454-CC-FTA) are required if ONS 15454 XC10G and ONS 15454 XC-VXC-10G cards are installed in the shelf. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-3 Chapter 1 Shelf and Backplane Hardware 1.2.1 Reversible Mounting Bracket Figure 1-1 Cisco ONS 15454 ANSI Dimensions Standard Door - Front View 18.25 in. (46.35 cm) Height Side View 16.78 in. (42.62 cm) 19 in. (48.26 cm) or 23 in. (58.42 cm) between mounting screw holes Width 5.015 in. (12.73 cm) 12.018 in. (30.52 cm) Depth Deep Door - Front View 18.25 in. (46.35 cm) Height Side View 16.78 in. (42.62 cm) 4.807 in. (12.20 cm) 13.810 in. (35.07 cm) Depth 240922 19 in. (48.26 cm) or 23 in. (58.42 cm) between mounting screw holes Width 1.2.1 Reversible Mounting Bracket Caution Use only the fastening hardware provided with the ONS 15454 to prevent loosening, deterioration, and electromechanical corrosion of the hardware and joined material. Cisco ONS 15454 Reference Manual, R8.5.x 1-4 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.2.2 Mounting a Single Node Caution When mounting the ONS 15454 in a frame with a nonconductive coating (such as paint, lacquer, or enamel) either use the thread-forming screws provided with the ONS 15454 shipping kit, or remove the coating from the threads to ensure electrical continuity. The shelf assembly comes preset for installation in a 23-inch (584.2 mm) rack, but you can reverse the mounting bracket to fit the smaller 19-inch (482.6 mm) rack. 1.2.2 Mounting a Single Node Mounting the ONS 15454 in a rack requires a minimum of 18.5 inches (469.9 mm) of vertical rack space and one additional inch (25.4 mm) for air flow. To ensure the mounting is secure, use two to four #12-24 mounting screws for each side of the shelf assembly. Figure 1-2 shows the rack mounting position for the ONS 15454. Figure 1-2 Mounting an ONS 15454 in a Rack 39392 Equipment rack FAN FA IL CR IT MA J MIN Universal ear mounts (reversible) Two people should install the shelf assembly; however, one person can install it using the temporary set screws included. The shelf assembly should be empty for easier lifting. The front door can also be removed to lighten the shelf assembly. If you are installing the fan-tray air filter using the bottom (external) brackets provided, mount the brackets on the bottom of the shelf assembly before installing the ONS 15454 in a rack. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-5 Chapter 1 Shelf and Backplane Hardware 1.2.3 Mounting Multiple Nodes 1.2.3 Mounting Multiple Nodes Most standard (Telcordia GR-63-CORE, 19-inch [482.6 mm] or 23-inch [584.2 mm]) seven-foot (2,133 mm) racks can hold four ONS 15454 shelves and a fuse and alarm panel. However, unequal flange racks are limited to three ONS 15454 shelves and a fuse and alarm panel or four ONS 15454 shelves and a fuse and alarm panel from an adjacent rack. If you are using the external (bottom) brackets to install the fan-tray air filter, you can install three shelf assemblies in a standard seven-foot (2.133 m) rack. If you are not using the external (bottom) brackets, you can install four shelf assemblies in a rack. The advantage to using the bottom brackets is that you can replace the filter without removing the fan tray. 1.2.4 ONS 15454 Bay Assembly The Cisco ONS 15454 bay assembly simplifies ordering and installing the ONS 15454 because it allows you to order shelf assemblies preinstalled in a seven-foot (2.133 m) rack. The bay assembly is available in a three- or four-shelf configuration. The three-shelf configuration includes three ONS 15454 shelf assemblies, a prewired fuse and alarm panel, and two cable-management trays. The four-shelf configuration includes four ONS 15454 shelf assemblies and a prewired fuse and alarm panel. You can order optional fiber channels with either configuration. Installation procedures are included in the Unpacking and Installing the Cisco ONS 15454 Four-Shelf and Zero-Shelf Bay Assembly document that ships with the Bay Assembly, 1.3 Front Door The Critical, Major, and Minor alarm LEDs visible through the front door indicate whether a critical, major, or minor alarm is present anywhere on the ONS 15454. These LEDs must be visible so technicians can quickly determine if any alarms are present on the ONS 15454 shelf or the network. You can use the LCD to further isolate alarms. The front door (Figure 1-3) provides access to the shelf assembly, cable-management tray, fan-tray assembly, and LCD screen. Cisco ONS 15454 Reference Manual, R8.5.x 1-6 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.3 Front Door Figure 1-3 The ONS 15454 Front Door CISCO ONS 15454 Optical Network System Door lock Door button 33923 Viewholes for Critical, Major and Minor alarm LEDs The ONS 15454 ships with a standard door but can also accommodate a deep door and extended fiber clips (15454-DOOR-KIT) to provide additional room for cabling (Figure 1-4). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-7 Chapter 1 Shelf and Backplane Hardware 1.3 Front Door Figure 1-4 Cisco ONS 15454 Deep Door 115011 . The ONS 15454 door locks with a pinned hex key that ships with the ONS 15454. A button on the right side of the shelf assembly releases the door. You can remove the front door of the ONS 15454 to provide unrestricted access to the front of the shelf assembly. Before you remove the front door, you have to remove the ground strap of the front door (Figure 1-5). Cisco ONS 15454 Reference Manual, R8.5.x 1-8 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.3 Front Door ONS 15454 Front Door Ground Strap 71048 Figure 1-5 Figure 1-6 shows how to remove the front door. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-9 Chapter 1 Shelf and Backplane Hardware 1.3 Front Door Removing the ONS 15454 Front Door FAN 38831 Figure 1-6 FAIL CR IT MA J MIN Translucent circles for LED viewing Door hinge Assembly hinge pin Assembly hinge An erasable label is pasted on the inside of the front door (Figure 1-7). You can use the label to record slot assignments, port assignments, card types, node ID, rack ID, and serial number for the ONS 15454. Cisco ONS 15454 Reference Manual, R8.5.x 1-10 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.4 Backplane Covers Front-Door Erasable Label 61840 Figure 1-7 Note The front door label also includes the Class I and Class 1M laser warning (Figure 1-8). Laser Warning on the Front-Door Label 67575 Figure 1-8 1.4 Backplane Covers If a backplane does not have an EIA panel installed, it should have two sheet metal backplane covers (one on each side of the backplane) as shown in Figure 1-9 on page 1-12. Each cover is held in place with nine 6-32 x 3/8 inch Phillips screws. Note See the “1.5 Electrical Interface Assemblies” section on page 1-15 for information on EIAs. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-11 Chapter 1 Shelf and Backplane Hardware 1.4.1 Lower Backplane Cover Figure 1-9 Backplane Covers B A Backplane Sheet Metal Covers 32074 Lower Backplane Cover 1.4.1 Lower Backplane Cover The lower section of the ONS 15454 backplane is covered by either a clear plastic protector (15454-SA-ANSI) or a sheet metal cover (15454-SA-HD), which is held in place by five 6-32 x 1/2 inch screws. Remove the lower backplane cover to access the alarm interface panel (AIP), alarm pin fields, frame ground, and power terminals (Figure 1-10). Removing the Lower Backplane Cover 32069 Figure 1-10 Retaining screws Cisco ONS 15454 Reference Manual, R8.5.x 1-12 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.4.2 Rear Cover 1.4.2 Rear Cover The ONS 15454 has an optional clear plastic rear cover. This clear plastic cover provides additional protection for the cables and connectors on the backplane. Figure 1-11 shows the rear cover screw locations. Figure 1-11 Backplane Attachment for Cover 32073 Screw locations for attaching the rear cover You can also install the optional spacers if more space is needed between the cables and rear cover (Figure 1-12). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-13 Chapter 1 Shelf and Backplane Hardware 1.4.3 Alarm Interface Panel 55374 S A UIT P N A -4 IN LE O B 65 2 N S A -C LE 0 TO TR S E O FO W -5 U R M at 7 C E B R ts V TI FE U M M dc S O O ax N R TI U S TO B N im . LE TI um IN N S S U G TA R O LL FA N A C TI E O . N Installing the Plastic Rear Cover with Spacers R E T C th AU 1 pr e TI io B O B r AT1 N A to : T se an R em 1 rv d ic te ov R in rm e E g T in po al w 2 bl er B oc fro A ks m T bo 2 th Figure 1-12 1.4.3 Alarm Interface Panel The AIP is located above the alarm contacts on the lower section of the backplane. The AIP provides surge protection for the ONS 15454. It also provides an interface from the backplane to the fan-tray assembly and LCD. The AIP plugs into the backplane using a 96-pin DIN connector and is held in place with two retaining screws. The panel has a nonvolatile memory chip that stores the unique node address (MAC address). Note The MAC address identifies the nodes that support circuits. It allows Cisco Transport Controller (CTC) to determine circuit sources, destinations, and spans. The TCC2/TCC2P cards in the ONS 15454 also use the MAC address to store the node database. The 5-A AIP (73-7665-XX) is required when installing fan-tray assembly 15454-FTA3 or 15454-CC-FTA, which comes preinstalled on the shelf assembly (15454-SA-ANSI or 15454-SA-HD). Note A blown fuse on the AIP board can cause the LCD display to go blank. 1.4.4 Alarm Interface Panel Replacement If the alarm interface panel (AIP) fails, a MAC Fail alarm appears on the CTC Alarms menu and/or the LCD display on the fan-tray assembly goes blank. To perform an in-service replacement of the AIP, you must contact Cisco Technical Assistance Center (TAC). For contact information, go to the TAC website at http://www.cisco.com/tac. Cisco ONS 15454 Reference Manual, R8.5.x 1-14 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5 Electrical Interface Assemblies You can replace the AIP on an in-service system without affecting traffic (except Ethernet traffic on nodes running a software release earlier than Release 4.0). The circuit repair feature allows you to repair circuits affected by MAC address changes on one node at a time. Circuit repair works when all nodes are running the same software version. Each individual AIP upgrade requires an individual circuit repair; if AIPs are replaced on two nodes, the circuit repair must be performed twice. Caution Note Do not use a 2-A AIP with a 5-A fan-tray assembly; doing so causes a blown fuse on the AIP. Ensure that all nodes in the affected network are running the same software version before replacing the AIP and repairing circuits. If you need to upgrade nodes to the same software version, do not change any hardware or repair circuits until after the software upgrade is complete. Replace an AIP during a maintenance window. Resetting the active TCC2/TCC2P card can cause a service disruption of less then 50 ms to optical or electrical traffic. Resetting the active TCC2/TCC2P card causes a service disruption of three to five minutes on all E-Series Ethernet traffic due to spanning tree reconvergence. Refer to the Cisco ONS 15454 Troubleshooting Guide for an AIP replacement procedure. 1.5 Electrical Interface Assemblies Optional EIA backplane covers are typically preinstalled when ordered with the ONS 15454. EIAs must be ordered when using DS-1, DS-3, DS3XM, or EC-1 cards. This section describes each EIA. Six different EIA backplane covers are available for the ONS 15454: BNC, High-Density BNC, MiniBNC, SMB, AMP Champ, UBIC-H (Universal Backplane Interface Connector-Horizontal), and UBIC-V (Vertical). If the shelf was not shipped with the correct EIA interface, you must order and install the correct EIA. EIAs are attached to the shelf assembly backplane to provide electrical interface cable connections. EIAs are available with SMB and BNC connectors for DS-3 or EC-1 cards. EIAs are available with AMP Champ connectors for DS-1 cards. You must use SMB EIAs for DS-1 twisted-pair cable installation. UBIC-V EIAs have SCSI connectors. They are available for use with any DS-1, DS-3, or EC-1 card, but are intended for use with high-density electrical cards. Note The MiniBNC EIAs only support cables using the Trompetor connectors for termination. You can install EIAs on one or both sides of the ONS 15454 backplane in any combination (in other words, AMP Champ on Side A and BNC on Side B or High-Density BNC on Side A and SMB on Side B, and so forth). As you face the rear of the ONS 15454 shelf assembly, the right side is the A side and the left side is the B side. The top of the EIA connector columns are labeled with the corresponding slot number, and EIA connector pairs are marked transmit (Tx) and receive (Rx) to correspond to transmit and receive cables. Note For information about EIA types, protection schemes, and card slots, see Chapter 7, “Card Protection.” Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-15 Chapter 1 Shelf and Backplane Hardware 1.5.1 EIA Installation 1.5.1 EIA Installation Optional EIA backplane covers are typically preinstalled when ordered with the ONS 15454. A minimal amount of assembly might be required when EIAs are ordered separately from the ONS 15454. If you are installing EIAs after the shelf assembly is installed, plug the EIA into the backplane. The EIA has six electrical connectors that plug into six corresponding backplane connectors. The EIA backplane must replace the standard sheet metal cover to provide access to the coaxial cable connectors. The EIA sheet metal covers use the same screw holes as the solid backplane panels, but they have 12 additional 6-32 x 1/2 inch Phillips screw holes so you can screw down the cover and the board using standoffs on the EIA board. When using the RG-179 coaxial cable on an EIA, the maximum distance available (122 feet [37 meters]) is less than the maximum distance available with standard RG-59 (734A) cable (306 feet [93 meters]). The maximum distance when using the RG-59 (734A) cable is 450 feet (137 meters). The shorter maximum distance available with the RG179 is due to a higher attenuation rate for the thinner cable. Attenuation rates are calculated using a DS-3 signal: • For RG-179, the attenuation rate is 59 dB/kft at 22 MHz. • For RG-59 (734A) the attenuation rate is 11.6 dB/kft at 22 MHz. 1.5.2 EIA Configurations Table 1-1 shows the EIA types supported only by ONS 15454 shelf assembly 15454-SA-ANSI. Table 1-1 EIA Types Compatible with the 15454-SA-ANSI Only A-Side Columns Map to A-Side Product Number Cards EIA Type Supported A-Side Hosts BNC DS-3 DS3XM-6 EC-1 24 pairs of Slot 2 BNC Slot 4 connectors 15454-EIA-BNC-A24= DS-3 DS3XM-6 EC-1 48 pairs of Slot 1 BNC Slot 2 connectors Slot 4 15454-EIA-BNC-A48= HighDensity BNC Slot 5 B-Side Hosts B-Side Columns Map to B-Side Product Number 24 pairs of BNC connectors Slot 14 48 pairs of BNC Slot 13 15454-EIA-BNC-B24= Slot 16 15454-EIA-BNC-B48= Slot 14 Slot 16 Slot 17 Cisco ONS 15454 Reference Manual, R8.5.x 1-16 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.2 EIA Configurations Table 1-1 EIA Types Compatible with the 15454-SA-ANSI Only (continued) A-Side Columns Map to A-Side Product Number Cards EIA Type Supported A-Side Hosts SMB 84 pairs of Slot 1 SMB Slot 2 connectors Slot 3 DS-1 DS-3 EC-1 DS3XM-6 AMP Champ DS-1 15454-EIA-SMB-A84= B-Side Hosts 84 pairs of SMB connectors B-Side Columns Map to B-Side Product Number Slot 12 Slot 13 Slot 14 Slot 4 Slot 15 Slot 5 Slot 16 Slot 6 Slot 17 6 AMP Slot 1 Champ Slot 2 connectors Slot 3 15454-EIA-SMB-B84= 15454-EIA-AMP-A84= 6 AMP Champ connectors Slot 12 15454-EIA-AMP-B84= Slot 13 Slot 14 Slot 4 Slot 15 Slot 5 Slot 16 Slot 6 Slot 17 Table 1-2 shows the EIA types supported by both the 15454-SA-ANSI and the 15454-SA-HD (high density) shelf assemblies. Table 1-2 EIA Configurations Compatible with the 15454-SA-ANSI and the 15454-SA-HD A-Side Columns Map to A-Side Product Number Cards Supported A-Side Hosts BNC DS-3 24 pairs of Slot 2 BNC Slot 4 connectors 15454-EIA-1BNCA24= 24 pairs of Slot 14 BNC Slot 16 connectors 15454-EIA-1BNCB24= 48 pairs of Slot 1 BNC Slot 2 connectors Slot 4 15454-EIA-1BNCA48= 48 pairs of Slot 13 BNC Slot 14 connectors Slot 16 15454-EIA-1BNCB48= DS3XM-6 B-Side Hosts B-Side Columns Map to B-Side Product Number EIA Type DS3XM-12 EC-1 High- DS-3 Densi DS3XM-6 ty BNC DS3XM-12 EC-1 Mini BNC Slot 17 Slot 5 96 pairs of Slot 1 MiniBNC Slot 2 DS-3/EC1-48 connectors Slot 4 DS3XM-6 DS-3 15454-EIA-BNC-A96= 96 pairs of Slot 12 MiniBNC Slot 13 connectors Slot 14 DS3XM-12 Slot 5 Slot 16 EC-1 Slot 6 Slot 17 15454-EIA-BNC-A96= Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-17 Chapter 1 Shelf and Backplane Hardware 1.5.3 BNC EIA Table 1-2 EIA Configurations Compatible with the 15454-SA-ANSI and the 15454-SA-HD (continued) A-Side Columns Map to A-Side Product Number EIA Type Cards Supported A-Side Hosts SMB DS-1 84 pairs of Slot 1 SMB Slot 2 connectors Slot 3 DS-3 EC-1 15454-EIA-1SMBA84= B-Side Hosts B-Side Columns Map to B-Side Product Number 84 pairs of Slot 12 SMB Slot 13 connectors Slot 14 DS3XM-6 Slot 4 Slot 15 DS3XM-12 Slot 5 Slot 16 Slot 6 Slot 17 AMP DS-1 Cham p 6 AMP Slot 1 Champ Slot 2 connectors Slot 3 EC-1 6 AMP Slot 12 Champ Slot 13 connectors Slot 14 Slot 4 Slot 15 Slot 5 Slot 16 Slot 6 Slot 17 8 pairs of Slot 1 SCSI Slot 2 connectors Slot 3 UBIC DS-1 -V DS-3 15454-EIA-1AMPA84= 15454-EIA-UBICV-A 8 pairs of Slot 12 SCSI Slot 13 connectors Slot 14 DS3XM-6 Slot 4 Slot 15 DS3XM-12 Slot 5 Slot 16 DS3/EC1-48 Slot 6 Slot 17 15454-EIA-1SMBB84= 15454-EIA-1AMPB84= 15454-EIA-UBICV-B DS1/E1-56 8 pairs of Slot 1 SCSI Slot 2 connectors Slot 3 UBIC DS-1 -H DS-3 EC-1 15454-EIA-UBICH-A 8 pairs of Slot 12 SCSI Slot 13 connectors Slot 14 DS3XM-6 Slot 4 Slot 15 DS3XM-12 Slot 5 Slot 16 DS3/EC1-48 Slot 6 Slot 17 15454-EIA-UBICH-B DS1/E1-56 1.5.3 BNC EIA The ONS 15454 BNC EIA supports 24 DS-3 circuits on each side of the ONS 15454 (24 transmit and 24 receive connectors). If you install BNC EIAs on both sides of the shelf assembly, the ONS 15454 hosts up to 48 circuits. The BNC connectors on the EIA supports Trompeter UCBJ224 (75-ohm) 4-leg connectors (King or ITT are also compatible). Right-angle mating connectors for the connecting cable are AMP 413588-2 (75-ohm) connectors. If preferred, you can also use a straight connector of the same Cisco ONS 15454 Reference Manual, R8.5.x 1-18 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.3 BNC EIA type. Use RG-59/U cable to connect to the ONS 15454 BNC EIA. These cables are recommended to connect to a patch panel and are designed for long runs. You can use BNC EIAs for DS-3 (including the DS3XM-6 and DS3XM-12) or EC-1 cards. Figure 1-13 shows the ONS 15454 with preinstalled BNC EIAs. To install coaxial cable with BNC connectors, refer to the “Install Shelf and Backplane Cable” chapter in the Cisco ONS 15454 Procedure Guide. Figure 1-13 BNC Backplane for Use in 1:1 Protection Schemes B 16 TX 14 TX RX TX RX 4 TX RX TX RX A 2 TX RX TX RX TX RX 1 7 1 7 1 7 1 7 2 8 2 8 2 8 2 8 3 9 3 9 3 9 3 9 4 10 4 10 4 10 4 10 5 11 5 11 5 11 5 11 6 RX TX 12 RX TX 6 RX TX 12 RX TX 6 RX TX 12 RX TX 6 RX TX 12 BNC backplane connectors Tie wrap posts RX 32076 TX RX 1.5.3.1 BNC Connectors The EIA side marked “A” has 24 pairs of BNC connectors. The first 12 pairs of BNC connectors correspond to Ports 1 to 12 for a 12-port card and map to Slot 2 on the shelf assembly. The BNC connector pairs are marked “Tx” and “Rx” to indicate transmit and receive cables for each port. You can install an additional card in Slot 1 as a protect card for the card in Slot 2. The second 12 BNC connector pairs correspond to Ports 1 to 12 for a 12-port card and map to Slot 4 on the shelf assembly. You can install an additional card in Slot 3 as a protect card for the card in Slot 4. Slots 5 and 6 do not support DS-3 cards when the standard BNC EIA panel connectors are used. The EIA side marked “B” provides an additional 24 pairs of BNC connectors. The first 12 BNC connector pairs correspond to Ports 1 to 12 for a 12-port card and map to Slot 14 on the shelf assembly. The BNC connector pairs are marked “Tx” and “Rx” to indicate transmit and receive cables for each port. You can install an additional card in Slot 15 as a protect card for the card in Slot 14. The second 12 BNC connector pairs correspond to Ports 1 to 12 for a 12-port card and map to Slot 16 on the shelf assembly. You can install an additional card in Slot 17 as a protect card for the card in Slot 16. Slots 12 and 13 do not support DS-3 cards when the standard BNC EIA panel connectors are used. When BNC connectors are used with a DS3N-12 card in Slot 3 or 15, the 1:N card protection extends only to the two slots adjacent to the 1:N card due to BNC wiring constraints. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-19 Chapter 1 Shelf and Backplane Hardware 1.5.4 High-Density BNC EIA 1.5.3.2 BNC Insertion and Removal Tool Due to the large number of BNC connectors on the high-density BNC EIA, you might require a special tool for inserting and removing BNC EIAs (Figure 1-14). This tool also helps with ONS 15454 patch panel connections. BNC Insertion and Removal Tool 44552 Figure 1-14 This tool can be obtained with P/N 227-T1000 from: Amphenol USA (www.amphenol.com) One Kennedy Drive Danbury, CT 06810 Phone: 203 743-9272 Fax: 203 796-2032 This tool can be obtained with P/N RT-4L from: Trompeter Electronics Inc. (www.trompeter.com) 31186 La Baya Drive Westlake Village, CA 91362-4047 Phone: 800 982-2629 Fax: 818 706-1040 1.5.4 High-Density BNC EIA The ONS 15454 high-density BNC EIA supports 48 DS-3 circuits on each side of the ONS 15454 (48 transmit and 48 receive connectors). If you install BNC EIAs on both sides of the unit, the ONS 15454 hosts up to 96 circuits. The high-density BNC EIA supports Trompeter UCBJ224 (75-ohm) 4-leg connectors (King or ITT are also compatible). Use straight connectors on RG-59/U cable to connect to the high-density BNC EIA. Cisco recommends these cables for connection to a patch panel; they are designed for long runs. You can use high-density BNC EIAs for DS-3 (including the DS3XM-6 and DS3XM-12) or EC-1 cards. Figure 1-15 shows the ONS 15454 with preinstalled high-density BNC EIAs. To install coaxial cable with high-density BNC connectors, refer to the “Install Shelf and Backplane Cable” in the Cisco ONS 15454 Procedure Guide. Cisco ONS 15454 Reference Manual, R8.5.x 1-20 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.5 MiniBNC EIA Figure 1-15 High-Density BNC Backplane for Use in 1:N Protection Schemes B 17 TX RX TX 14 RX TX 13 RX TX 5 RX TX 4 RX TX 2 RX TX 1 RX TX RX 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 7 7 7 7 7 7 7 7 8 8 8 8 8 8 8 8 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 11 11 11 11 11 11 11 11 12 12 12 12 12 12 12 RX TX RX TX RX TX RX TX RX TX RX TX A BNC backplane connectors 12 RX TX RX 39141 TX 16 The EIA side marked “A” hosts 48 pairs of BNC connectors. Each column of connector pairs is numbered and corresponds to the slot of the same number. The first column (12 pairs) of BNC connectors corresponds to Slot 1 on the shelf assembly, the second column to Slot 2, the third column to Slot 4, and the fourth column to Slot 5. The rows of connectors correspond to Ports 1 to 12 of a 12-port card. The EIA side marked “B” provides an additional 48 pairs of BNC connectors. The first column (12 pairs) of BNC connectors corresponds to Slot 13 on the shelf assembly, the second column to Slot 14, the third column to Slot 16, and the fourth column to Slot 17. The rows of connectors correspond to Ports 1 to 12 of a 12-port card. The BNC connector pairs are marked “Tx” and “Rx” to indicate transmit and receive cables for each port. The High-Density BNC EIA supports both 1:1 and 1:N protection across all slots except Slots 6 and 12. 1.5.5 MiniBNC EIA The ONS 15454 MiniBNC EIA supports a maximum of 192 transmit and receive DS-3 connections, 96 per side (A and B) through 192 miniBNC connectors on each side. If you install BNC EIAs on both sides of the unit, the ONS 15454 hosts up to 192 circuits. The MiniBNC EIAs are designed to support DS-3 and EC-1 signals. The MiniBNC EIA supports the following cards: • DS3-12, DS3N-12 • DS3i-N-12 • DS3-12E, DS3N-12E • EC1-12 • DS3XM-6 • DS3XM-12 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-21 Chapter 1 Shelf and Backplane Hardware 1.5.5 MiniBNC EIA • DS3/EC1-48 MiniBNCs support available high-density cards in unprotected and 1:N protection (where N < 2) protection groups. Table 1-3 shows protection groups and their applicable slot assignments. Table 1-3 MiniBNC Protection Types and Slots Protection Type Working Slots Protection Slots Unprotected 1–6, 12–17 — 1:1 2, 4, 6, 12, 14, 16 1, 3, 5, 13, 15, 17 1:N (HD, where N < 5) 1, 2, 16, 17 3, 15 1:N (LD, where N < 2) 1, 2, 4, 5, 6, 12, 13, 14, 16, 17 3, 15 1.5.5.1 MiniBNC Connectors You can install MiniBNCs on one or both sides of the ONS 15454. As you face the rear of the ONS 15454 shelf assembly, the right side is the A side (15454-EIA-BNC-A96) and the left side is the B side (15454-EIA-BNC-A96). The diagrams adjacent to each row of connectors indicate the slots and ports that correspond with each connector in that row, depending on whether you are using a high density (HD) or low density (LD) configuration. The MiniBNC connector pairs are marked Tx and Rx to indicate transmit and receive cables for each port. Figure 1-16 shows the ONS 15454 with preinstalled MiniBNC EIAs. To install coaxial cable with MiniBNC connectors, refer to the “Install the Shelf and Backplane Cable” chapter in the Cisco ONS 15454 Procedure Guide. Cisco ONS 15454 Reference Manual, R8.5.x 1-22 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.5 MiniBNC EIA Figure 1-16 MiniBNC Backplane for Use in 1:N Protection Schemes Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-23 Chapter 1 Shelf and Backplane Hardware 1.5.5 MiniBNC EIA Table 1-4 and Table 1-5 show the J-labeling and corresponding card ports for a shelf assembly configured with low-density electrical cards. Table 1-4 J-Labeling Port Assignments for a Shelf Assembly Configure with Low-Density Electrical Cards (A Side) TX RX J4 J3 J2 J1 J5 J6 J7 J8 T1 T13 T25 T37 T1 T13 T25 T37 T2 T14 T26 T38 T2 T14 T26 T38 T3 T15 T27 T39 T3 T15 T27 T39 T4 T16 T28 T40 T4 T16 T28 T40 T5 T17 T29 T41 T5 T17 T29 T41 T6 T18 T30 T42 T6 T18 T30 T42 T7 T19 T31 T43 T7 T19 T31 T43 T8 T20 T32 T44 T8 T20 T32 T44 T9 T21 T33 T45 T9 T21 T33 T45 T10 T22 T34 T46 T10 T22 T34 T46 T11 T23 T35 T47 T11 T23 T35 T47 T12 T24 T36 T48 T12 T24 T36 T48 J12 J11 J10 J9 J13 J14 J15 J16 R1 R13 R25 R37 R1 R13 R25 R37 R2 R14 R26 R38 R2 R14 R26 R38 R3 R15 R27 R39 R3 R15 R27 R39 R4 R16 R28 R40 R4 R16 R28 R40 R5 R17 R29 R41 R5 R17 R29 R41 R6 R18 R30 R42 R6 R18 R30 R42 R7 R19 R31 R43 R7 R19 R31 R43 R8 R20 R32 R44 R8 R20 R32 R44 R9 R21 R33 R45 R9 R21 R33 R45 R10 R22 R34 R46 R10 R22 R34 R46 R11 R23 R35 R47 R11 R23 R35 R47 R12 R24 R36 R48 R12 R24 R36 R48 Slot Port Type Ports Ports Ports Ports Ports Ports Ports Ports 1 LD DS-3 1–12 — — — — — — — 2 LD DS-3 — — — — 1–12 — — — 3 LD DS-3 — — — — — — 1–12 — 4 LD DS-3 — — — — — 1–12 — — 5 LD DS-3 — 1–12 — — — — — — 6 LD DS-3 — — 1–12 — — — — Cisco ONS 15454 Reference Manual, R8.5.x 1-24 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.5 MiniBNC EIA Table 1-5 J-Labeling Port Assignments for a Shelf Assembly Configured with Low-Density Electrical Cards (B Side) TX RX J20 J19 J18 J17 J21 J22 J23 J24 T1 T13 T25 T37 T1 T13 T25 T37 T2 T14 T26 T38 T2 T14 T26 T38 T3 T15 T27 T39 T3 T15 T27 T39 T4 T16 T28 T40 T4 T16 T28 T40 T5 T17 T29 T41 T5 T17 T29 T41 T6 T18 T30 T42 T6 T18 T30 T42 T7 T19 T31 T43 T7 T19 T31 T43 T8 T20 T32 T44 T8 T20 T32 T44 T9 T21 T33 T45 T9 T21 T33 T45 T10 T22 T34 T46 T10 T22 T34 T46 T11 T23 T35 T47 T11 T23 T35 T47 T12 T24 T36 T48 T12 T24 T36 T48 J28 J27 J26 J25 J29 J30 J31 J32 R1 R13 R25 R37 R1 R13 R25 R37 R2 R14 R26 R38 R2 R14 R26 R38 R3 R15 R27 R39 R3 R15 R27 R39 R4 R16 R28 R40 R4 R16 R28 R40 R5 R17 R29 R41 R5 R17 R29 R41 R6 R18 R30 R42 R6 R18 R30 R42 R7 R19 R31 R43 R7 R19 R31 R43 R8 R20 R32 R44 R8 R20 R32 R44 R9 R21 R33 R45 R9 R21 R33 R45 R10 R22 R34 R46 R10 R22 R34 R46 R11 R23 R35 R47 R11 R23 R35 R47 R12 R24 R36 R48 R12 R24 R36 R48 Slot Port Type Ports Ports Ports Ports Ports Ports Ports Ports 17 LD DS-3 1–12 — — — — — — — 16 LD DS-3 — — — — 1–12 — — — 15 LD DS-3 — — — — — — 1–12 — 14 LD DS-3 — — — — — 1–12 — — 13 LD DS-3 — 1–12 — — — — — — 12 LD DS-3 — — 1–12 — — — — Table 1-6 and Table 1-7 show the J-labeling and corresponding card ports for a shelf assembly configured with high-density 48-port DS-3/EC-1electrical cards. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-25 Chapter 1 Shelf and Backplane Hardware 1.5.5 MiniBNC EIA Table 1-6 J-Labeling Port Assignments for a Shelf Configured with High-Density Electrical Cards (A Side) TX RX J4 J3 J2 J1 J5 J6 J7 J8 T1 T13 T25 T37 T1 T13 T25 T37 T2 T14 T26 T38 T2 T14 T26 T38 T3 T15 T27 T39 T3 T15 T27 T39 T4 T16 T28 T40 T4 T16 T28 T40 T5 T17 T29 T41 T5 T17 T29 T41 T6 T18 T30 T42 T6 T18 T30 T42 T7 T19 T31 T43 T7 T19 T31 T43 T8 T20 T32 T44 T8 T20 T32 T44 T9 T21 T33 T45 T9 T21 T33 T45 T10 T22 T34 T46 T10 T22 T34 T46 T11 T23 T35 T47 T11 T23 T35 T47 T12 T24 T36 T48 T12 T24 T36 T48 J12 J11 J10 J9 J13 J14 J15 J16 R1 R13 R25 R37 R1 R13 R25 R37 R2 R14 R26 R38 R2 R14 R26 R38 R3 R15 R27 R39 R3 R15 R27 R39 R4 R16 R28 R40 R4 R16 R28 R40 R5 R17 R29 R41 R5 R17 R29 R41 R6 R18 R30 R42 R6 R18 R30 R42 R7 R19 R31 R43 R7 R19 R31 R43 R8 R20 R32 R44 R8 R20 R32 R44 R9 R21 R33 R45 R9 R21 R33 R45 R10 R22 R34 R46 R10 R22 R34 R46 R11 R23 R35 R47 R11 R23 R35 R47 R12 R24 R36 R48 R12 R24 R36 R48 Slot Port Type Ports Ports Ports Ports Ports Ports Ports Ports 1 HD DS-3 1–12 13–24 25–36 37–48 — — — — 2 HD DS-3 — — — — 1–12 13–24 25–36 37–48 Cisco ONS 15454 Reference Manual, R8.5.x 1-26 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.5 MiniBNC EIA Table 1-7 J-Labeling Port Assignments for a Shelf Configured with High-Density Electrical Cards (B Side) TX RX J20 J19 J18 J17 J21 J22 J23 J24 T1 T13 T25 T37 T1 T13 T25 T37 T2 T14 T26 T38 T2 T14 T26 T38 T3 T15 T27 T39 T3 T15 T27 T39 T4 T16 T28 T40 T4 T16 T28 T40 T5 T17 T29 T41 T5 T17 T29 T41 T6 T18 T30 T42 T6 T18 T30 T42 T7 T19 T31 T43 T7 T19 T31 T43 T8 T20 T32 T44 T8 T20 T32 T44 T9 T21 T33 T45 T9 T21 T33 T45 T10 T22 T34 T46 T10 T22 T34 T46 T11 T23 T35 T47 T11 T23 T35 T47 T12 T24 T36 T48 T12 T24 T36 T48 J28 J27 J26 J25 J29 J30 J31 J32 R1 R13 R25 R37 R1 R13 R25 R37 R2 R14 R26 R38 R2 R14 R26 R38 R3 R15 R27 R39 R3 R15 R27 R39 R4 R16 R28 R40 R4 R16 R28 R40 R5 R17 R29 R41 R5 R17 R29 R41 R6 R18 R30 R42 R6 R18 R30 R42 R7 R19 R31 R43 R7 R19 R31 R43 R8 R20 R32 R44 R8 R20 R32 R44 R9 R21 R33 R45 R9 R21 R33 R45 R10 R22 R34 R46 R10 R22 R34 R46 R11 R23 R35 R47 R11 R23 R35 R47 R12 R24 R36 R48 R12 R24 R36 R48 Slot Port Type Ports Ports Ports Ports Ports Ports Ports Ports 17 HD DS-3 1–12 13–24 25–36 37–48 — — — — 16 HD DS-3 — — — — 1–12 13–24 25–36 37–48 1.5.5.2 MiniBNC Insertion and Removal Tool Due to the large number of MiniBNC connectors on the MiniBNC EIA, you might require a special tool for inserting and removing MiniBNC EIAs (Figure 1-17). This tool also helps with ONS 15454 patch panel connections. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-27 Chapter 1 Shelf and Backplane Hardware 1.5.6 SMB EIA MiniBNC Insertion and Removal Tool 115419 Figure 1-17 This tool can be obtained with P/N 227-T1000 from: Amphenol USA (www.amphenol.com) One Kennedy Drive Danbury, CT 06810 Phone: 203 743-9272 Fax: 203 796-2032 This tool can be obtained with P/N RT-1L from: Trompeter Electronics Inc. (www.trompeter.com) 31186 La Baya Drive Westlake Village, CA 91362-4047 Phone: 800 982-2629 Fax: 818 706-1040 1.5.6 SMB EIA The ONS 15454 SMB EIA supports AMP 415484-1 75-ohm 4-leg connectors. Right-angle mating connectors for the connecting cable are AMP 415484-2 (75-ohm) connectors. Use RG-179/U cable to connect to the ONS 15454 EIA. Cisco recommends these cables for connection to a patch panel; they are not designed for long runs. Range does not affect loopback testing. You can use SMB EIAs with DS-1, DS-3 (including the DS3XM-6 and DS3XM-12), and EC-1 cards. If you use DS-1 cards, use the DS-1 electrical interface adapter (balun) to terminate the twisted pair DS-1 cable to the SMB EIA (see the “1.7.2 Electrical Interface Adapters” section on page 1-39). SMB EIAs support 14 ports per slot when used with a DS-1 card, 12 ports per slot when used with a DS-3 or EC-1 card, and 6 ports per slot when used with a DS3XM-6 card. Figure 1-18 shows the ONS 15454 with preinstalled SMB EIAs and the sheet metal cover and screw locations for the EIA. The SMB connectors on the EIA are AMP 415504-3 (75-ohm) 4-leg connectors. To install SMB connectors, refer to the “Install Shelf and Backplane Cable” chapter in the Cisco ONS 15454 Procedure Guide. Cisco ONS 15454 Reference Manual, R8.5.x 1-28 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.7 AMP Champ EIA Figure 1-18 SMB EIA Backplane B TX 12x DS-3s 16 RX TX 15 RX TX RX TX 14 RX TX 13 RX 6 12 TX TX RX 5 RX TX 4 RX TX 3 RX TX 2 RX TX A 1 RX TX RX 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 11 11 11 11 12 12 12 12 13 13 13 13 14 14 14 TX RX TX RX TX RX TX RX TX RX TX RX SMB backplane connectors Tie wrap posts 14 TX RX TX RX TX RX TX RX TX RX TX RX 32101 Reserved for DS-1s 17 1 The SMB EIA has 84 transmit and 84 receive connectors on each side of the ONS 15454 for a total of 168 SMB connectors (84 circuits). The EIA side marked “A” hosts 84 SMB connectors in six columns of 14 connectors. The “A” side columns are numbered 1 to 6 and correspond to Slots 1 to 6 on the shelf assembly. The EIA side marked “B” hosts an additional 84 SMB connectors in six columns of 14 connectors. The “B” side columns are numbered 12 to 17 and correspond to Slots 12 to 17 on the shelf assembly. The connector rows are numbered 1 to 14 and correspond to the 14 ports on a DS-1 card. For DS-3 or EC-1 cards, the EIA supports 72 transmit and 72 receive connectors, for a total of 144 SMB connectors (72 circuits). If you use a DS-3 or EC-1 card, only Ports 1 to 12 are active. If you use a DS3XM-6 card, only Ports 1 to 6 are active. The SMB connector pairs are marked “Tx” and “Rx” to identify transmit and receive cables for each port. If you use SMB connectors, you can install DS-1, DS-3, or EC-1 cards in Slots 1 to 4 or 14 to 17. 1.5.7 AMP Champ EIA The ONS 15454 AMP Champ EIA supports 64-pin (32 pair) AMP Champ connectors for each slot on both sides of the shelf assembly where the EIA is installed. Cisco AMP Champ connectors are female AMP # 552246-1 with AMP # 552562-2 bail locks. Each AMP Champ connector supports 14 DS-1 ports. You can use AMP Champ EIAs with DS-1 cards only. Figure 1-19 shows the ONS 15454 with preinstalled AMP Champ EIAs and the corresponding sheet metal cover and screw locations for the EIA. To install AMP Champ connector DS-1 cables, you must use 64-pin bundled cable connectors with a 64-pin male AMP Champ connector. You need an AMP Champ connector #552276-1 for the receptacle side and #1-552496-1 (for cable diameter 0.475 in. to 0.540 in.) or #2-552496-1 (for cable diameter 0.540 in. to 0.605 in.) for the right-angle shell housing (or their functional equivalent). The corresponding 64-pin female AMP Champ connector on the AMP Champ EIA supports one receive and one transmit for each DS-1 port for the corresponding card slot. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-29 Chapter 1 Shelf and Backplane Hardware 1.5.7 AMP Champ EIA Because each DS1-14 card supports 14 DS-1 ports, only 56 pins (28 pairs) of the 64-pin connector are used. Prepare one 56-wire cable for each DS-1 facility installed. Figure 1-19 AMP Champ EIA Backplane 32070 AMP CHAMP connector Table 1-8 shows the pin assignments for the AMP Champ connectors on the ONS 15454 AMP Champ EIA. The EIA side marked “A” hosts six AMP Champ connectors. The connectors are numbered 1 to 6 for the corresponding slots on the shelf assembly. Each AMP Champ connector on the backplane supports 14 DS-1 ports for a DS1-14 card, and each connector features 28 live pairs—one transmit pair and one receive pair—for each DS-1 port. The EIA side marked “B” hosts six AMP Champ connectors. The connectors are labeled 12 to 17 for the corresponding slots on the shelf assembly. Each AMP Champ connector on the backplane supports 14 DS-1 ports for a DS1-14 card, and each connector features 28 live pairs—one transmit pair and one receive pair—for each DS-1 port. Note Caution EIAs are hot-swappable. You do not need to disconnect power to install or remove EIAs. Always use an electrostatic discharge (ESD) wristband when working with a powered ONS 15454. Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly. Cisco ONS 15454 Reference Manual, R8.5.x 1-30 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.7 AMP Champ EIA Table 1-8 AMP Champ Connector Pin Assignments Signal/Wire Pin Pin Signal/Wire Signal/Wire Pin Pin Signal/Wire Tx Tip 1 white/blue 1 33 Tx Ring 1 blue/white Rx Tip 1 yellow/orange 17 49 Rx Ring 1 orange/yellow Tx Tip 2 white/orange 2 34 Tx Ring 2 orange/white Rx Tip 2 yellow/green 18 50 Rx Ring 2 green/yellow Tx Tip 3 white/green 3 35 Tx Ring 3 green/white Rx Tip 3 yellow/brown 19 51 Rx Ring 3 brown/yellow Tx Tip 4 white/brown 4 36 Tx Ring 4 brown/white Rx Tip 4 yellow/slate 20 52 Rx Ring 4 slate/yellow Tx Tip 5 white/slate 5 37 Tx Ring 5 slate/white Rx Tip 5 violet/blue 21 53 Rx Ring 5 blue/violet Tx Tip 6 red/blue 6 38 Tx Ring 6 blue/red Rx Tip 6 violet/orange 22 54 Rx Ring 6 orange/violet Tx Tip 7 red/orange 7 39 Tx Ring 7 orange/red Rx Tip 7 violet/green 23 55 Rx Ring 7 green/violet Tx Tip 8 red/green 8 40 Tx Ring 8 green/red Rx Tip 8 violet/brown 24 56 Rx Ring 8 brown/violet Tx Tip 9 red/brown 9 41 Tx Ring 9 brown/red Rx Tip 9 violet/slate 25 57 Rx Ring 9 slate/violet Tx Tip 10 red/slate 10 42 Tx Ring 10 slate/red Rx Tip 10 white/blue 26 58 Rx Ring 10 blue/white Tx Tip 11 black/blue 11 43 Tx Ring 11 blue/black Rx Tip 11 white/orange 27 59 Rx Ring 11 orange/white Tx Tip 12 black/orange 12 44 Tx Ring 12 orange/black Rx Tip 12 white/green 28 60 Rx Ring 12 green/white Tx Tip 13 black/green 13 45 Tx Ring 13 green/black Rx Tip 13 white/brown 29 61 Rx Ring 13 brown/white Tx Tip 14 black/brown 14 46 Tx Ring 14 brown/black Rx Tip 14 white/slate 30 62 Rx Ring 14 slate/white Tx Spare0+ N/A 15 47 Tx Spare0– N/A Rx Spare0+ N/A 31 63 Rx Spare0– N/A Tx Spare1+ N/A 16 48 Tx Spare1– N/A Rx Spare1+ N/A 32 64 Rx Spare1– N/A Table 1-9 shows the pin assignments for the AMP Champ connectors on the ONS 15454 AMP Champ EIA for a shielded DS-1 cable. Table 1-9 AMP Champ Connector Pin Assignments (Shielded DS-1 Cable) 64-Pin Blue Bundle 64-Pin Orange Bundle Signal/Wire Pin Pin Signal/Wire Signal/Wire Pin Pin Signal/Wire Tx Tip 1 white/blue 1 33 Tx Ring 1 blue/white Rx Tip 1 white/blue 17 49 Rx Ring 1 blue/white Tx Tip 2 white/orange 2 34 Tx Ring 2 orange/white Rx Tip 2 white/orange 18 50 Rx Ring 2 orange/white Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-31 Chapter 1 Shelf and Backplane Hardware 1.5.8 UBIC-V EIA Table 1-9 AMP Champ Connector Pin Assignments (Shielded DS-1 Cable) (continued) 64-Pin Blue Bundle 64-Pin Orange Bundle Signal/Wire Pin Pin Signal/Wire Signal/Wire Pin Pin Signal/Wire Tx Tip 3 white/green 3 35 Tx Ring 3 green/white Rx Tip 3 white/green 19 51 Rx Ring 3 green/white Tx Tip 4 white/brown 4 36 Tx Ring 4 brown/white Rx Tip 4 white/brown 20 52 Rx Ring 4 brown/white Tx Tip 5 white/slate 5 37 Tx Ring 5 slate/white Rx Tip 5 white/slate 21 53 Rx Ring 5 slate/white Tx Tip 6 red/blue 6 38 Tx Ring 6 blue/red Rx Tip 6 red/blue 22 54 Rx Ring 6 blue/red Tx Tip 7 red/orange 7 39 Tx Ring 7 orange/red Rx Tip 7 red/orange 23 55 Rx Ring 7 orange/red Tx Tip 8 red/green 8 40 Tx Ring 8 green/red Rx Tip 8 red/green 24 56 Rx Ring 8 green/red Tx Tip 9 red/brown 9 41 Tx Ring 9 brown/red Rx Tip 9 red/brown 25 57 Rx Ring 9 brown/red Tx Tip 10 red/slate 10 42 Tx Ring 10 slate/red Rx Tip 10 red/slate 26 58 Rx Ring 10 slate/red Tx Tip 11 black/blue 11 43 Tx Ring 11 blue/black Rx Tip 11 black/blue 27 59 Rx Ring 11 blue/black Tx Tip 12 black/orange 12 44 Tx Ring 12 orange/black Rx Tip 12 black/orange 28 60 Rx Ring 12 orange/black Tx Tip 13 black/green 13 45 Tx Ring 13 green/black Rx Tip 13 black/green 29 61 Rx Ring 13 green/black Tx Tip 14 black/brown 14 46 Tx Ring 14 brown/black Rx Tip 14 black/brown 30 62 Rx Ring 14 brown/black Tx Tip 15 black/slate 15 47 Tx Tip 15 slate/black Rx Tip 15 black/slate 31 63 Rx Tip 15 slate/black Tx Tip 16 yellow/blue 16 48 Tx Tip 16 blue/yellow Rx Tip 16 yellow/blue 32 64 Rx Tip 16 blue/yellow When using DS-1 AMP Champ cables, you must equip the ONS 15454 with an AMP Champ connector EIA on each side of the backplane where DS-1 cables will terminate. Each AMP Champ connector on the EIA corresponds to a slot in the shelf assembly and is numbered accordingly. The AMP Champ connectors have screw-down tooling at each end of the connector. 1.5.8 UBIC-V EIA UBIC-V EIAs are attached to the shelf assembly backplane to provide up to 112 transmit and receive connections through 16 SCSI connectors per side (A and B). The UBIC-V EIAs are designed to support DS-1, DS-3, and EC-1 signals. The appropriate cable assembly is required depending on the type of signal. Cisco ONS 15454 Reference Manual, R8.5.x 1-32 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.8 UBIC-V EIA You can install UBIC-Vs on one or both sides of the ONS 15454. As you face the rear of the ONS 15454 shelf assembly, the right side is the A side (15454-EIA-UBICV-A) and the left side is the B side (15454-EIA-UBICV-B). The diagrams adjacent to each row of SCSI connectors indicate the slots and ports that correspond with each SCSI connector in that row, depending on whether you are using a high-density (HD) or low-density (LD) configuration. UBIC-V EIAs will support high-density electrical cards (DS3/EC1-48, DS1/E1-56), as well as low-density electrical cards. Figure 1-20 shows the A- and B-side slot assignments. UBIC-V Slot Designations JACKSCREW SHOULD BE INSTALLED FIRST AND REMOVED LAST A Tx DS3 1-12 DS1 1-14 DS3 1-12 DS1 1-14 DS3 25-36 DS1 29-42 J23 UNUSED DS3 1-12 DS1 1-14 J7 J5 J4 J1 REAR COVER BRACKET LOCATION Rx Rx J15 J13 J12 J9 Tx HD(SLOT 1) HD(SLOT 2) JACKSCREW SHOULD BE INSTALLED FIRST AND REMOVED LAST DS3 37-48 DS1 43-56 DS3 13-24 DS1 15-28 DS3 13-24 DS1 15-28 DS3 25-36 DS1 29-42 HD(SLOT 16) HD(SLOT 17) J24 J22 J19 J18 Rx DS3 37-48 DS1 43-56 Tx DS3 37-48 DS1 43-56 DS3 25-36 DS1 29-42 J31 DS3 13-24 DS1 15-28 DS3 1-12 DS1 1-14 J29 DS3 1-12 DS1 1-14 DS3 1-12 DS1 1-14 J28 DS3 13-24 DS1 15-28 DS3 37-48 DS1 43-56 J25 JACKSCREW SHOULD BE INSTALLED FIRST AND REMOVED LAST DS3 1-12 DS1 1-14 HD(SLOT 2) HD(SLOT 1) HD(SLOT 17) HD(SLOT 16) DS3 25-36 DS1 29-42 REAR COVER BRACKET LOCATION J2 J3 J6 J8 Rx HD(SLOT 1) HD(SLOT 2) DS3 37-48 DS1 43-56 DS3 13-24 DS1 15-28 DS3 13-24 DS1 15-28 DS3 25-36 DS1 29-42 DS3 25-36 DS1 29-42 DS3 13-24 DS1 15-28 DS3 13-24 DS1 15-28 DS3 37-48 DS1 43-56 HD(SLOT 16) HD(SLOT 17) J32 J30 J27 J26 J10 J11 J14 J16 UNUSED DS3 1-12 DS1 1-14 DS3 1-12 DS1 1-14 UNUSED RX DS3 1-12 DS1 1-14 LD DS3 1-12 DS1 1-14 DS3 1-12 DS1 1-14 DS3 1-12 DS1 1-14 (SLOT 6) (SLOT 5) (SLOT 4) TX DS3 1-12 DS1 1-14 DS3 1-12 DS1 1-14 DS3 1-12 DS1 1-14 DS3 1-12 DS1 1-14 REAR COVER BRACKET LOCATION UNUSED LD DS3 1-12 DS1 1-14 UNUSED (SLOT 14)(SLOT 13)(SLOT 12) DS3 1-12 DS1 1-14 JACKSCREW SHOULD BE INSTALLED FIRST AND REMOVED LAST UNUSED DS3 37-48 DS1 43-56 DS3 37-48 DS1 43-56 J21 DS3 1-12 DS1 1-14 HD(SLOT 2) HD(SLOT 1) HD(SLOT 17) HD(SLOT 16) J20 RX DS3 1-12 DS1 1-14 Tx J17 DS3 1-12 DS1 1-14 P RX TX DS3 25-36 DS1 29-42 P LD DS3 1-12 DS1 1-14 P TX DS3 25-36 DS1 29-42 DS3 1-12 DS1 1-14 DS3 1-12 DS1 1-14 P DS3 1-12 DS1 1-14 DS3 1-12 DS1 1-14 UNUSED UNUSED LD DS1/DS3 DS1/DS3 DS3 1-12 DS1 1-14 (SLOT 3) (SLOT 2) (SLOT 1) (SLOT 17)(SLOT 16)(SLOT 15) TX RX REAR COVER BRACKET LOCATION 102176 B JACKSCREW SHOULD BE INSTALLED FIRST AND REMOVED LAST JACKSCREW SHOULD BE INSTALLED FIRST AND REMOVED LAST Figure 1-20 The UBIC-V sheet metal covers use the same screw holes as the standard sheet metal covers, but they have 12 additional holes for pan-head screws and three holes for jack screws, so you can screw down the cover and the board using standoffs on the UBIC-V board. When installed with the standard door and cabling on the backplane, the ONS 15454 shelf measures approximately 15.7 inches (399 mm) deep when partially populated with backplane cables, 16.1 inches (409 mm) deep when fully populated, and 16.75 inches (425 mm) deep with the rear cover installed. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-33 Chapter 1 Shelf and Backplane Hardware 1.5.9 UBIC-H EIA When installed with the deep door and cabling on the backplane, the ONS 15454 shelf measures approximately 17.5 inches (445 mm) deep when partially populated with backplane cables, 17.9 inches (455 mm) deep when fully populated, and 18.55 inches (471 mm) deep with the rear cover installed. The UBIC-V EIA supports the following cards: • DS1-14, DS1N-14 • DS3-12, DS3N-12 • DS3i-N-12 • DS3-12E, DS3N-12E • EC1-12 • DS3XM-6 • DS3XM-12 • DS3/EC1-48 • DS1/E1-56 The A and B sides each host 16 high-density, 50-pin SCSI connectors. The A-side maps to Slots 1 through 6 and the B-side maps to Slots 12 through 17. In Software Releases 4.1.x and 4.6, UBIC-Vs support unprotected, 1:1, and 1:N (N < 5) protection groups. In Software R5.0 and later, UBIC-Vs also support available high-density cards in unprotected and 1:N (N < 2) protection groups. Table 1-10 shows the UBIC-V protection types and their applicable slot assignments. Table 1-10 UBIC-V Protection Types and Slots Protection Type Working Slots Protection Slots Unprotected 1–6, 12–17 — 1:1 2, 4, 6, 12, 14, 16 1, 3, 5, 13, 15, 17 1:2 1, 2, 16, 17 3, 15 1:5 1, 2, 4, 5, 6, 12, 13, 14, 16, 17 3, 15 1.5.9 UBIC-H EIA UBIC-H EIAs are attached to the shelf assembly backplane to provide up to 112 transmit and receive DS-1 connections through 16 SCSI connectors per side (A and B) or 96 transmit and receive DS-3 connections. The UBIC-H EIAs are designed to support DS-1, DS-3, and EC-1 signals. The appropriate cable assembly is required depending on the type of signal. You can install UBIC-Hs on one or both sides of the ONS 15454. As you face the rear of the ONS 15454 shelf assembly, the right side is the A side (15454-EIA-UBICH-A) and the left side is the B side (15454-EIA-UBICH-B). The diagrams adjacent to each row of SCSI connectors indicate the slots and ports that correspond with each SCSI connector in that row, depending on whether you are using a high density (HD) or low density (LD) configuration. Note UBIC-H EIAs will support use with the high-density (DS3/EC1-48, DS1/E1-56, and DS3XM-12) electrical cards, as well as existing low-density electrical cards. Cisco ONS 15454 Reference Manual, R8.5.x 1-34 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.9 UBIC-H EIA Figure 1-21 shows the A- and B-side connector labeling. UBIC-H EIA Connector Labeling 124533 Figure 1-21 Tables 1-11 and 1-12 show the J-labeling and corresponding card ports for a shelf assembly configured with low-density electrical cards. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-35 Chapter 1 Shelf and Backplane Hardware 1.5.9 UBIC-H EIA Table 1-11 J-Labeling Port Assignments for a Shelf Assembly Configured with Low-Density Electrical Cards (A Side) TX J4 J3 J2 J1 J5 J6 J7 J8 RX J12 J11 J10 J9 J13 J14 J15 J16 Slot Port Type Ports Ports Ports Ports Ports Ports Ports Ports 1 DS-1 1–14 — — — — — — — DS-3 1–12 — — — — — — — DS-1 — — — — 1–14 — — — DS-3 — — — — 1–12 — — — DS-1 — — — — — — 1–14 — DS-3 — — — — — — 1–12 — DS-1 — — — — — 1–14 — — DS-3 — — — — — 1–12 — — DS-1 — 1–14 — — — — — — DS-3 — 1–12 — — — — — — DS-1 — — 1–14 — — — — — DS-3 — — 1–12 — — — — — 2 3 4 5 6 Table 1-12 J-Labeling Port Assignments for a Shelf Assembly Configured with Low-Density Electrical Cards (B Side) TX J20 J19 J18 J17 J21 J22 J23 24 RX J28 J27 J26 J25 J29 J30 J31 J32 Slot Port Type Ports Ports Ports Ports Ports Ports Ports Ports 17 DS-1 1–14 — — — — — — — DS-3 1–12 — — — — — — — DS-1 — — — — 1–14 — — — DS-3 — — — — 1–12 — — — DS-1 — — — — — — 1–14 — DS-3 — — — — — — 1–12 — DS-1 — — — — — 1–14 — — DS-3 — — — — — 1–12 — — DS-1 — 1–14 — — — — — — DS-3 — 1–12 — — — — — — DS-1 — — 1–14 — — — — — DS-3 — — 1–12 — — — — — 16 15 14 13 12 Tables 1-13 and 1-14 show the J-labeling and corresponding card ports for a shelf assembly configured with high-density 48-port DS-3/EC-1 or 56-port DS-1 electrical cards. Cisco ONS 15454 Reference Manual, R8.5.x 1-36 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.5.9 UBIC-H EIA Table 1-13 J-Labeling Port Assignments for a Shelf Configured with High-Density Electrical Cards (A Side) TX J4 J3 J2 J1 J5 J6 J7 J8 RX J12 J11 J10 J9 J13 J14 J15 J16 Slot Port Type Ports Ports Ports Ports Ports Ports Ports Ports 1 DS-1 1–14 15–28 29–42 43–56 — — — — DS-3 1–12 13–24 25–36 37–48 — — — — DS-1 — — — — 1–14 15–28 29–42 43–56 DS-3 — — — — 1–12 13–24 25–36 37–48 2 Table 1-14 J-Labeling Port Assignments for a Shelf Configured with High-Density Electrical Cards (B Side) TX J20 J19 J18 J17 J21 J22 J23 24 RX J28 J27 J26 J25 J29 J30 J31 J32 Slot Port Type Ports Ports Ports Ports Ports Ports Ports Ports 17 DS-1 1–14 15–28 29–42 43–56 — — — — DS-3 1–12 13–24 25–36 37–48 — — — — DS-1 — — — — 1–14 15–28 29–42 43–56 DS-3 — — — — 1–12 13–24 25–36 37–48 16 If you are installing UBIC-H EIAs after the shelf assembly is installed, plug the UBIC-H EIA into the backplane. The UBIC-H backplane must replace the standard sheet metal cover to provide access to the cable connectors. The UBIC-H sheet metal covers use the same screw holes as the standard sheet metal covers, but they have 12 additional holes for panhead screws and three holes for jack screws so you can screw down the cover and the board using standoffs on the UBIC-H board. When installed with the standard door and cabling on the backplane, the ONS 15454 shelf measures approximately 14.5 inches deep when fully populated with backplane cables, and 15.0 inches deep with the rear cover installed. When installed with the deep door and cabling on the backplane, the ONS 15454 shelf measures approximately 16.5 inches deep when fully populated with backplane cables, and 17.0 inches deep with the rear cover installed. The UBIC-H EIA supports the following cards: • DS1-14, DS1N-14 • DS3-12, DS3N-12 • DS3-12E, DS3N-12E • EC1-12 • DS3XM-6 • DS3XM-12 • DS3/EC1-48 • DS1/E1-56 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-37 Chapter 1 Shelf and Backplane Hardware 1.5.10 EIA Replacement The A and B sides each host 16 high-density, 50-pin SCSI connectors. The A-side maps to Slots 1 through 6 and the B-side maps to Slots 12 through 17. In Software Releases prior to Release 5.0, UBIC-Hs support unprotected, 1:1, and 1:N (where N < 5) protection groups. In Software R5.0 and greater, UBIC-Hs additionally support available high-density cards in unprotected and 1:N protection (where N < 2) protection groups. Table 1-15 shows protection groups and their applicable slot assignments. Table 1-15 UBIC-H Protection Types and Slots Protection Type Working Slots Protection Slots Unprotected 1–6, 12–17 — 1:1 2, 4, 6, 12, 14, 16 1, 3, 5, 13, 15, 17 1:2 1, 2, 16, 17 3, 15 1:5 1, 2, 4, 5, 6, 12, 13, 14, 16, 17 3, 15 1.5.10 EIA Replacement Before you attach a new EIA, you must remove the backplane cover or EIA already installed on the ONS 15454. Refer to the spare document(s) for the EIA type(s) you are removing and replacing for specific information. 1.6 Coaxial Cable Caution Always use the supplied ESD wristband when working with a powered ONS 15454. Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly. When using ONS 15454 DS-3 electrical cables, the cables must terminate on an EIA installed on the ONS 15454 backplane. All DS-3 cables connected to the ONS 15454 DS-3 card must terminate with coaxial cables using the desired connector type to connect to the specified EIA. The electromagnetic compatibility (EMC) performance of the node depends on good-quality DS-3 coaxial cables, such as Shuner Type G 03233 D, or the equivalent. 1.7 DS-1 Cable DS-1 cables support AMP Champ connectors and twisted-pair wire-wrap cabling. Twisted-pair wire-wrap cables require SMB EIAs. 1.7.1 Twisted Pair Wire-Wrap Cables Installing twisted-pair, wire-wrap DS-1 cables requires separate pairs of grounded twisted-pair cables for receive (in) and transmit (out). Prepare four cables, two for receive and two for transmit, for each DS-1 facility to be installed. Cisco ONS 15454 Reference Manual, R8.5.x 1-38 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.7.2 Electrical Interface Adapters Caution Always use the supplied ESD wristband when working with a powered ONS 15454. Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly. If you use DS-1 electrical twisted-pair cables, equip the ONS 15454 with an SMB EIA on each side of the backplane where DS-1 cables will terminate. You must install special DS-1 electrical interface adapters, commonly referred to as a balun, on every transmit and receive connector for each DS-1 termination. 1.7.2 Electrical Interface Adapters Note DS-1 electrical interface adapters project an additional 1.72 inches (43.7 mm) from the ONS 15454 backplane. If you install DS-1 cards in the ONS 15454, you must fit the corresponding transmit and receive SMB connectors on the EIA with a DS-1 electrical interface adapter. You can install the adapter on the SMB connector for the port. The adapter has wire-wrap posts for DS-1 transmit and receive cables. Figure 1-22 shows the DS-1 electrical interface adapter. “EIA” refers to electrical interface assemblies and not electrical interface adapters. Electrical interface adapters are also known as baluns. Figure 1-22 SMB Connector DS-1 Electrical interface adapter DS-1 Electrical Interface Adapter (Balun) Wire wrap posts Ring Tip 32071 Note Each DS-1 electrical interface adapter has a female SMB connector on one end and a pair of 0.045 inch (1.14 mm) square wire-wrap posts on the other end. The wire-wrap posts are 0.200 inches (5.08 mm) apart. Caution Always use the supplied ESD wristband when working with a powered ONS 15454. Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-39 Chapter 1 Shelf and Backplane Hardware 1.8 UBIC-V Cables 1.8 UBIC-V Cables Note Cisco Systems announced the end-of-sale and end-of-life dates for the Cisco ONS 15454 MSPP Universal BackPlane Interface Adapter, Vertical Orientation (UBIC-V), and its DS1 and DS3 Cables. For further details, refer to Product Bulletin No. EOL5039 at http://www.cisco.com/en/US/partner/prod/collateral/optical/ps5724/ps2006/prod_end-of-life_notice09 00aecd8052a481.html. The UBIC-V EIA is designed to support DS-1, DS-3, or EC-1 signals. The type of signal supported is determined by the respective UBIC-V cable assembly. DS-1 cables for the UBIC-V have a maximum supported distance of 655 feet (199.6 m). DS-1 cables arrive with unterminated #24 AWG twisted pairs on the far end and are color coded as identified in Table 1-17. The following DS-1 cables are no longer available from Cisco Systems for use with the UBIC-V EIA: • DS-1 cable, 150 feet: 15454-CADS1-SD • DS-1 cable, 250 feet: 15454-CADS1-ID • DS-1 cable, 655 feet: 15454-CADS1-LD DS-3/EC-1 cables for the UBIC-V have a maximum supported distance of 450 feet (137.2 m). DS-3/EC-1 cables arrive with unterminated coaxial cable at the far end and labeled with the respective port number. 75-ohm BNC connectors for each port (qty. 12) are supplied and require that they be crimped on. The following DS-3/EC-1 cables are no longer available from Cisco Systems for use with the UBIC-V EIA: • DS-3/EC-1 cable, 75 feet: 15454-CADS3-SD • DS-3/EC-1 cable, 225 feet: 15454-CADS3-ID • DS-3/EC-1 cable, 450 feet: 15454-CADS3-LD Figure 1-23 Cable Connector Pins Pin 1 Pin 25 Pin 26 Pin 50 115171 Figure 1-23 identifies the pin numbers for the DS-1 and DS-3/EC-1 cables as referenced from the SCSI connector. Table 1-16 identifies the UBIC-V SCSI connector pin assignments for the DS-1 cables as referenced from the EIA backplane to the SCSI connector. Note Conversion from the back plane’s single ended (unbalanced) 75-ohm signal to a differential (balanced) 100-ohm signal happens through the embedded transformer within the SCSI connector. The cable's shield is connected to the connector shell. This conversion is illustrated in Figure 1-24. Cisco ONS 15454 Reference Manual, R8.5.x 1-40 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.8 UBIC-V Cables Table 1-16 UBIC-V DS-1 SCSI Connector Pin Out Port SCSI Pin SCSI Pin Port #1 1 26 #7 FGnd 2 27 FGnd FGnd 3 28 FGnd FGnd 4 29 FGnd #2 5 30 #8 FGnd 6 31 FGnd FGnd 7 32 FGnd FGnd 8 33 FGnd #3 9 34 #9 FGnd 10 35 FGnd FGnd 11 36 FGnd FGnd 12 37 FGnd #4 13 38 #10 FGnd 14 39 FGnd FGnd 15 40 FGnd FGnd 16 41 FGnd #5 17 42 #11 FGnd 18 43 FGnd FGnd 19 44 FGnd FGnd 20 45 FGnd #6 21 46 #12 FGnd 22 47 FGnd FGnd 23 48 FGnd FGnd 24 49 FGnd #13 25 50 #14 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-41 Chapter 1 Shelf and Backplane Hardware 1.8 UBIC-V Cables Figure 1-24 UBIC-V DS-1 Cable Schematic Diagram UBIC-V DS-1 Cable Shield to connector shell Pin 1 75Ω Signal To/From UBIC-V DS1 75Ω Port #1 1:1.15 Tip DS1 #1 100Ω Differential DS-1 To/From DSx Ring DS1 #1 FGND Pin 2 — FGnd Pin 3 — FGnd Pin 4 — FGnd Pin 5 75Ω Signal To/From UBIC-V DS1 75Ω Port #2 1:1.15 Tip DS1 #2 100Ω Differential DS-1 To/From DSx Ring DS1 #2 FGND To/From Customer DSX To/From SCSI connector on the UBIC-V EIA 1:1.15 Shield to connector shell Tip DS1 #13 75Ω Signal To/From UBIC-V Ring DS1 #13 FGND Pin 50 75Ω Signal To/From UBIC-V DS1 75Ω Port #14 100Ω Differential DS-1 To/From DSx 1:1.15 Tip DS1 #14 100Ω Differential DS-1 To/From DSx Ring DS1 #14 FGND 273810 Pin 25 DS1 75Ω Port #13 Table 1-17 shows the UBIC-V DS-1 Tip/Ring color coding. Cisco ONS 15454 Reference Manual, R8.5.x 1-42 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.8 UBIC-V Cables Table 1-17 UBIC-V DS-1 Tip/Ring Color Coding Wire Color Signal Signal Wire Color White/blue Tip DS-1 #1 Ring DS-1 #1 Blue/white White/orange Tip DS-1 #2 Ring DS-1 #2 Orange/white White/green Tip DS-1 #3 Ring DS-1 #3 Green/white White/brown Tip DS-1 #4 Ring DS-1 #4 Brown/white White/slate Tip DS-1 #5 Ring DS-1 #5 Slate/white Red/blue Tip DS-1 #6 Ring DS-1 #6 Blue/red Red/orange Tip DS-1 #7 Ring DS-1 #7 Orange/red Red/green Tip DS-1 #8 Ring DS-1 #8 Green/red Red/brown Tip DS-1 #9 Ring DS-1 #9 Brown/red Red/slate Tip DS-1 #10 Ring DS-1 #10 Slate/red Black/blue Tip DS-1 #11 Ring DS-1 #11 Blue/black Black/orange Tip DS-1 #12 Ring DS-1 #12 Orange/black Black/green Tip DS-1 #13 Ring DS-1 #13 Green/black Black/brown Tip DS-1 #14 Ring DS-1 #14 Brown/black Table 1-18 identifies the UBIC-V SCSI connector pin assignments for the DS-3/EC-1 cables as referenced from the EIA backplane to the SCSI connector. Table 1-18 UBIC-V DS-3/EC-1 SCSI Connector Pin Out Port SCSI Pin SCSI Pin Port #1 1 26 #7 FGnd 2 27 FGnd FGnd 3 28 FGnd FGnd 4 29 FGnd #2 5 30 #8 FGnd 6 31 FGnd FGnd 7 32 FGnd FGnd 8 33 FGnd #3 9 34 #9 FGnd 10 35 FGnd FGnd 11 36 FGnd FGnd 12 37 FGnd #4 13 38 #10 FGnd 14 39 FGnd FGnd 15 40 FGnd FGnd 16 41 FGnd Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-43 Chapter 1 Shelf and Backplane Hardware 1.8 UBIC-V Cables Table 1-18 UBIC-V DS-3/EC-1 SCSI Connector Pin Out (continued) Port SCSI Pin SCSI Pin Port #5 17 42 #11 FGnd 18 43 FGnd FGnd 19 44 FGnd FGnd 20 45 FGnd #6 21 46 #12 FGnd 22 47 FGnd FGnd 23 48 FGnd FGnd 24 49 FGnd Not connected 25 50 Not connected Figure 1-25 shows the UBIC-V DS-3/EC-1 cable schematic diagram. Cisco ONS 15454 Reference Manual, R8.5.x 1-44 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.9 UBIC-H Cables Figure 1-25 UBIC-V DS-3/EC-1 Cable Schematic Diagram DS-3/EC1 Cable Pin 1 DS-3 75Ω Port #1 Port #1 75Ω Signal To/From UBIC Frame GND from shield to connector Pin 5 DS-3 75Ω Port #2 Port #2 75Ω Signal To/From FGND From/To Customer DSx Pin 42 DS-3 75Ω Port #11 Port #11 75Ω Signal To/From FGND Pin 46 DS-3 75Ω Port #12 Port #12 75Ω Signal To/From 75Ω DS-3/EC1 signal coming to/from Tyco SCSI connector and being placed on 735A (or 735C) Coax 273811 FGND 1.9 UBIC-H Cables The UBIC-H EIA is designed to support DS-1, DS-3, or EC-1 signals. The type of signal supported is determined by the UBIC-H cable assembly that you order. To support DS-1 signals, select the DS-1 UBIC-H cable assembly (part number 15454-CADS1-H-). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-45 Chapter 1 Shelf and Backplane Hardware 1.9 UBIC-H Cables To support DS-3 or EC-1 signals, select the DS-3/EC-1 UBIC-H cable assembly (part number 15454-CADS3-H- ). DS-1 cables for the UBIC-H have a maximum supported distance of 655 feet (199.6 m). DS-1 cables arrive with unterminated #24 AWG twisted pairs on the far end and are color coded as identified in Table 1-20. The following DS-1 cables are available from Cisco Systems for use with the UBIC-H EIA: • 25 feet: 15454-CADS1-H-25 • 50 feet: 15454-CADS1-H-50 • 75 feet: 15454-CADS1-H-75 • 100 feet: 15454-CADS1-H-100 • 150 feet: 15454-CADS1-H-150 • 200 feet: 15454-CADS1-H-200 • 250 feet: 15454-CADS1-H-250 • 350 feet: 15454-CADS1-H-350 • 450 feet: 15454-CADS1-H-450 • 550 feet: 15454-CADS1-H-550 • 655 feet: 15454-CADS1-H-655 DS-3/EC-1 cables for the UBIC-H have a maximum supported distance of 450 feet (137.2 m). DS-3/EC-1 cables arrive with unterminated coaxial cable at the far end and labeled with the respective port number. 75-ohm BNC connectors for each port (qty. 12) are supplied and require that they be crimped on. The following DS-3/EC-1 cables are available from Cisco Systems for use with the UBIC-H EIA: • 25 feet: 15454-CADS3-H-25 • 50 feet: 15454-CADS3-H-50 • 75 feet: 15454-CADS3-H-75 • 100 feet: 15454-CADS3-H-100 • 125 feet: 15454-CADS3-H-125 • 150 feet: 15454-CADS3-H-150 • 175 feet: 15454-CADS3-H-175 • 200 feet: 15454-CADS3-H-200 • 225 feet: 15454-CADS3-H-225 • 250 feet: 15454-CADS3-H-250 • 300 feet: 15454-CADS3-H-300 • 350 feet: 15454-CADS3-H-350 • 450 feet: 15454-CADS3-H-450 Figure 1-26 identifies the pin numbers for the DS-1 and DS-3/EC-1 cables as referenced from the SCSI connector. Cisco ONS 15454 Reference Manual, R8.5.x 1-46 78-18106-01 Chapter 1 Shelf and Backplane Hardware Figure 1-26 Cable Connector Pins Pin 1 Pin 25 Pin 26 Pin 50 115171 1.9 UBIC-H Cables Table 1-19 identifies the UBIC-H SCSI connector pin assignments for the DS-1 cables as referenced from the EIA backplane to the SCSI connector. Note Conversion from the back plane’s single ended (unbalanced) 75-ohm signal to a differential (balanced) 100-ohm signal happens through the embedded transformer within the SCSI connector. The cable's shield is connected to the connector shell. This conversion is illustrated in Figure 1-27. Table 1-19 UBIC-H DS-1 SCSI Connector Pin Out Port SCSI Pin SCSI Pin Port #1 1 26 #7 FGnd 2 27 FGnd FGnd 3 28 FGnd FGnd 4 29 FGnd #2 5 30 #8 FGnd 6 31 FGnd FGnd 7 32 FGnd FGnd 8 33 FGnd #3 9 34 #9 FGnd 10 35 FGnd FGnd 11 36 FGnd FGnd 12 37 FGnd #4 13 38 #10 FGnd 14 39 FGnd FGnd 15 40 FGnd FGnd 16 41 FGnd #5 17 42 #11 FGnd 18 43 FGnd FGnd 19 44 FGnd FGnd 20 45 FGnd #6 21 46 #12 FGnd 22 47 FGnd Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-47 Chapter 1 Shelf and Backplane Hardware 1.9 UBIC-H Cables Table 1-19 UBIC-H DS-1 SCSI Connector Pin Out (continued) Port SCSI Pin SCSI Pin Port FGnd 23 48 FGnd FGnd 24 49 FGnd #13 25 50 #14 Figure 1-27 UBIC-H DS-1 Cable Schematic Diagram UBIC-H DS-1 Cable Shield to connector shell Pin 1 75Ω Signal To/From UBIC-H DS1 75Ω Port #1 1:1.15 Tip DS1 #1 100Ω Differential DS-1 To/From DSx Ring DS1 #1 FGND Pin 2 — FGnd Pin 3 — FGnd Pin 4 — FGnd Pin 5 75Ω Signal To/From UBIC-H DS1 75Ω Port #2 1:1.15 Tip DS1 #2 100Ω Differential DS-1 To/From DSx Ring DS1 #2 FGND To/From Customer DSX 1:1.15 Shield to connector shell Tip DS1 #13 75Ω Signal To/From UBIC-H Ring DS1 #13 FGND Pin 50 75Ω Signal To/From UBIC-H DS1 75Ω Port #14 100Ω Differential DS-1 To/From DSx 1:1.15 Tip DS1 #14 Ring DS1 #14 FGND 273808 Pin 25 DS1 75Ω Port #13 Table 1-20 shows the UBIC-H DS-1 Tip/Ring color coding. Cisco ONS 15454 Reference Manual, R8.5.x 1-48 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.9 UBIC-H Cables Table 1-20 UBIC-H DS-1 Tip/Ring Color Coding Wire Color Signal Signal Wire Color White/blue Tip DS-1 #1 Ring DS-1 #1 Blue/white White/orange Tip DS-1 #2 Ring DS-1 #2 Orange/white White/green Tip DS-1 #3 Ring DS-1 #3 Green/white White/brown Tip DS-1 #4 Ring DS-1 #4 Brown/white White/slate Tip DS-1 #5 Ring DS-1 #5 Slate/white Red/blue Tip DS-1 #6 Ring DS-1 #6 Blue/red Red/orange Tip DS-1 #7 Ring DS-1 #7 Orange/red Red/green Tip DS-1 #8 Ring DS-1 #8 Green/red Red/brown Tip DS-1 #9 Ring DS-1 #9 Brown/red Red/slate Tip DS-1 #10 Ring DS-1 #10 Slate/red Black/blue Tip DS-1 #11 Ring DS-1 #11 Blue/black Black/orange Tip DS-1 #12 Ring DS-1 #12 Orange/black Black/green Tip DS-1 #13 Ring DS-1 #13 Green/black Black/brown Tip DS-1 #14 Ring DS-1 #14 Brown/black Table 1-21 identifies the UBIC-H SCSI connector pin assignments for the DS-3/EC-1 cables as referenced from the EIA backplane to the SCSI connector. Table 1-21 UBIC-H DS-3/EC-1 SCSI Connector Pin Out Port SCSI Pin SCSI Pin Port #1 1 26 #7 FGnd 2 27 FGnd FGnd 3 28 FGnd FGnd 4 29 FGnd #2 5 30 #8 FGnd 6 31 FGnd FGnd 7 32 FGnd FGnd 8 33 FGnd #3 9 34 #9 FGnd 10 35 FGnd FGnd 11 36 FGnd FGnd 12 37 FGnd #4 13 38 #10 FGnd 14 39 FGnd FGnd 15 40 FGnd FGnd 16 41 FGnd Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-49 Chapter 1 Shelf and Backplane Hardware 1.9 UBIC-H Cables Table 1-21 UBIC-H DS-3/EC-1 SCSI Connector Pin Out (continued) Port SCSI Pin SCSI Pin Port #5 17 42 #11 FGnd 18 43 FGnd FGnd 19 44 FGnd FGnd 20 45 FGnd #6 21 46 #12 FGnd 22 47 FGnd FGnd 23 48 FGnd FGnd 24 49 FGnd Not connected 25 50 Not connected Figure 1-28 shows the UBIC-H DS-3/EC-1 cable schematic diagram Cisco ONS 15454 Reference Manual, R8.5.x 1-50 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.10 Ethernet Cables Figure 1-28 UBIC-H DS-3/EC-1 Cable Schematic Diagram DS-3/EC1 Cable Pin 1 DS-3 75Ω Port #1 Port #1 75Ω Signal To/From UBIC Pin 5 DS-3 75Ω Port #2 Port #2 75Ω Signal To/From FGND From/To Customer DSx Pin 42 DS-3 75Ω Port #11 Port #11 75Ω Signal To/From FGND Pin 46 DS-3 75Ω Port #12 Port #12 75Ω DS-3/EC1 signal coming to/from Tyco SCSI connector and being placed on 735A (or 735C) Coax 273809 75Ω Signal To/From 1.10 Ethernet Cables Ethernet cables use RJ-45 connectors, and are straight-through or crossover, depending on what is connected to them. Table 1-22 shows 100Base-TX connector pin assignments, used with E100 Ethernet cards in the ONS 15454. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-51 Chapter 1 Shelf and Backplane Hardware 1.10 Ethernet Cables Table 1-22 E100-TX Connector Pinout Pin Cable Port 1 RD+ 2 RD– 3 TD+ 4 NC 5 NC 6 TD– 7 NC 8 NC Figure 1-29 shows the pin locations on 100BaseT connector. Figure 1-29 100BaseT Connector Pins H5436 1234567 8 Figure 1-30 shows the straight-through Ethernet cable schematic. Use a straight-through cable when connecting to a router or a PC. Straight-Through Cable Switch Router or PC 3 TD+ 6 TD– 3 RD+ 6 RD– 1 RD+ 2 RD– 1 TD+ 2 TD– H5578 Figure 1-30 Cisco ONS 15454 Reference Manual, R8.5.x 1-52 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.11 Cable Routing and Management Figure 1-31 shows the crossover Ethernet cable schematic. Use a crossover cable when connecting to a switch or hub. Crossover Cable Switch Switch 3 TD+ 6 TD– 3 TD+ 6 TD– 1 RD+ 2 RD– 1 RD+ 2 RD– H5579 Figure 1-31 1.11 Cable Routing and Management The ONS 15454 cable management facilities include the following: • A cable-routing channel (behind the fold-down door) that runs the width of the shelf assembly (Figure 1-32) • Plastic horseshoe-shaped fiber guides at each side opening of the cable-routing channel that ensure the proper bend radius is maintained in the fibers (Figure 1-33) Note You can remove the fiber guide if necessary to create a larger opening (if you need to route CAT-5 Ethernet cables out the side, for example). To remove the fiber guide, take out the three screws that anchor it to the side of the shelf assembly. • A fold-down door that provides access to the cable-management tray • Cable tie-wrap facilities on EIAs that secure cables to the cover panel • A cable routing channel that enables you to route cables out either side • Jumper slack storage reels (2) on each side panel that reduce the amount of slack in cables that are connected to other devices Note • To remove the jumper slack storage reels, take out the screw in the center of each reel. Optional tie-down bar Figure 1-32 shows the cable management facilities that you can access through the fold-down front door, including the cable-routing channel and cable-routing channel posts. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-53 Chapter 1 Shelf and Backplane Hardware 1.11.1 Fiber Management Figure 1-32 Managing Cables on the Front Panel FAN FAIL CR IT MA J MIN 145262 Cable-routing channel posts Fold down front door 1.11.1 Fiber Management The jumper routing fins are designed to route fiber jumpers out of both sides of the shelf. Slots 1 to 6 exit to the left, and Slots 12 to 17 exit to the right. Figure 1-33 shows fibers routed from cards in the left slots, down through the fins, then exiting out the fiber channel to the left. The maximum capacity of the fiber routing channel depends on the size of the fiber jumpers. Table 1-23 gives the maximum capacity of the fiber channel for each side of the shelf, for the different fiber sizes. Fiber Capacity 96518 Figure 1-33 Fiber guides Cisco ONS 15454 Reference Manual, R8.5.x 1-54 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.11.2 Fiber Management Using the Tie-Down Bar Table 1-23 provides the maximum capacity of the fiber channel for one side of a shelf, depending on fiber size and number of Ethernet cables running through that fiber channel. Table 1-23 Fiber Channel Capacity (One Side of the Shelf) Maximum Number of Fibers Exiting Each Side Fiber Diameter No Ethernet Cables One Ethernet Cable Two Ethernet Cables 1.6 mm (0.6 inch) 144 127 110 2 mm (0.7 inch) 90 80 70 3 mm (0.11 inch) 40 36 32 Plan your fiber size according to the number of cards/ports installed in each side of the shelf. For example, if your port combination requires 36 fibers, 3 mm (0.11 inch) fiber is adequate. If your port combination requires 68 fibers, you must use 2 mm(0.7 inch) or smaller fibers. 1.11.2 Fiber Management Using the Tie-Down Bar You can install an optional 5-inch (127 mm) tie-down bar on the rear of the ANSI chassis. You can use tie-wraps or other site-specific material to bundle the cabling and attach it to the bar so that you can more easily route the cable away from the rack. Figure 1-34 shows the tie-down bar, the ONS 15454, and the rack. Figure 1-34 Tie-Down Bar 105012 Tie-down bar Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-55 Chapter 1 Shelf and Backplane Hardware 1.11.3 Coaxial Cable Management 1.11.3 Coaxial Cable Management Coaxial cables connect to EIAs on the ONS 15454 backplane using cable connectors. EIAs feature cable-management eyelets for tie wrapping or lacing cables to the cover panel. 1.11.4 DS-1 Twisted-Pair Cable Management Connect twisted pair/DS-1 cables to SMB EIAs on the ONS 15454 backplane using cable connectors and DS-1 EIAs (baluns). 1.11.5 AMP Champ Cable Management EIAs have cable management eyelets to tiewrap or lace cables to the cover panel. Tie wrap or lace the AMP Champ cables according to local site practice and route the cables. If you configure the ONS 15454 for a 23-inch (584.2 mm) rack, two additional inches (50.8 mm) of cable management area is available on each side of the shelf assembly. 1.12 Alarm Expansion Panel The optional ONS 15454 alarm expansion panel (AEP) can be used with the Alarm Interface Controller—International card (AIC-I) card to provide an additional 48 dry alarm contacts for the ONS 15454, 32 of which are inputs and 16 are outputs. The AEP is a printed circuit board assembly that is installed on the backplane. Figure 1-35 shows the AEP board; the left connector is the input connector and the right connector is the output connector. The AIC-I without an AEP already contains direct alarm contacts. These direct AIC-I alarm contacts are routed through the backplane to wire-wrap pins accessible from the back of the shelf. If you install an AEP, you cannot use the alarm contacts on the wire-wrap pins. For further information about the AIC-I, see the “2.7 AIC-I Card” section on page 2-28. Cisco ONS 15454 Reference Manual, R8.5.x 1-56 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.12.1 Wire-Wrap and Pin Connections Figure 1-35 AEP Printed Circuit Board Assembly 78471 Input Connector Output Connector Figure 1-36 shows the AEP block diagram. Figure 1-36 AEP Block Diagram AIC-I Interface (wire wrapping) TIA/EIA 485 In Alarm Relays Out Alarm Relays 78406 Inventory data (EEPROM) AEP/AIE CPLD Power Supply Each AEP alarm input port has provisionable label and severity. The alarm inputs have optocoupler isolation. They have one common 48-VDC output and a maximum of 2 mA per input. Each opto metal oxide semiconductor (MOS) alarm output can operate by definable alarm condition, a maximum open circuit voltage of 60 VDC, anda maximum current of 100 mA. See the “2.7.2 External Alarms and Controls” section on page 2-30 for further information. 1.12.1 Wire-Wrap and Pin Connections Figure 1-37 shows the wire-wrapping connections on the backplane. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-57 Chapter 1 Shelf and Backplane Hardware 1.12.1 Wire-Wrap and Pin Connections Figure 1-37 AEP Wire-Wrap Connections to Backplane Pins Table 1-24 shows the backplane pin assignments and corresponding signals on the AIC-I and AEP. Table 1-24 Pin Assignments for the AEP AEP Cable Wire Backplane Pin AIC-I Signal AEP Signal Black A1 GND AEP_GND White A2 AE_+5 AEP_+5 Slate A3 VBAT– VBAT– Violet A4 VB+ VB+ Blue A5 AE_CLK_P AE_CLK_P Green A6 AE_CLK_N AE_CLK_N Yellow A7 AE_DIN_P AE_DOUT_P Orange A8 AE_DIN_N AE_DOUT_N Red A9 AE_DOUT_P AE_DIN_P Brown A10 AE_DOUT_N AE_DIN_N Figure 1-38 is a circuit diagram of the alarm inputs (Inputs 1 and 32 are shown in the example). Cisco ONS 15454 Reference Manual, R8.5.x 1-58 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.12.1 Wire-Wrap and Pin Connections Figure 1-38 Alarm Input Circuit Diagram Station AEP/AIE 48 V GND max. 2 mA Input 1 VBAT– Input 48 78473 VBAT– Table 1-25 lists the connections to the external alarm sources. Table 1-25 Alarm Input Pin Association AMP Champ Pin Number Signal Name AMP Champ Pin Number Signal Name 1 ALARM_IN_1– 27 GND 2 GND 28 ALARM_IN_2– 3 ALARM_IN_3– 29 ALARM_IN_4– 4 ALARM_IN_5– 30 GND 5 GND 31 ALARM_IN_6– 6 ALARM_IN_7– 32 ALARM_IN_8– 7 ALARM_IN_9– 33 GND 8 GND 34 ALARM_IN_10– 9 ALARM_IN_11– 35 ALARM_IN_12– 10 ALARM_IN_13– 36 GND 11 GND 37 ALARM_IN_14– 12 ALARM_IN_15– 38 ALARM_IN_16– 13 ALARM_IN_17– 39 GND 14 GND 40 ALARM_IN_18– 15 ALARM_IN_19– 41 ALARM_IN_20– 16 ALARM_IN_21– 42 GND 17 GND 43 ALARM_IN_22– 18 ALARM_IN_23– 44 ALARM_IN_24– 19 ALARM_IN_25– 45 GND Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-59 Chapter 1 Shelf and Backplane Hardware 1.12.1 Wire-Wrap and Pin Connections Table 1-25 Alarm Input Pin Association (continued) AMP Champ Pin Number Signal Name AMP Champ Pin Number Signal Name 20 GND 46 ALARM_IN_26– 21 ALARM_IN_27– 47 ALARM_IN_28– 22 ALARM_IN_29– 48 GND 23 GND 49 ALARM_IN_30– 24 ALARM_IN_31– 50 N.C. 25 ALARM_IN_+ 51 GND1 26 ALARM_IN_0– 52 GND2 Figure 1-39 is a circuit diagram of the alarm outputs (Outputs 1 and 16 are shown in the example). Figure 1-39 Alarm Output Circuit Diagram Station AEP/AIE Output 1 max. 60 V/100 mA 78474 Output 16 Use the pin numbers in Table 1-26 to connect to the external elements being switched by external alarms. Table 1-26 Pin Association for Alarm Output Pins AMP Champ Pin Number Signal Name AMP Champ Pin Number Signal Name 1 N.C. 27 COM_0 2 COM_1 28 N.C. 3 NO_1 29 NO_2 4 N.C. 30 COM_2 5 COM_3 31 N.C. 6 NO_3 32 NO_4 Cisco ONS 15454 Reference Manual, R8.5.x 1-60 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.13 Filler Card Table 1-26 Pin Association for Alarm Output Pins (continued) AMP Champ Pin Number Signal Name AMP Champ Pin Number Signal Name 7 N.C. 33 COM_4 8 COM_5 34 N.C. 9 NO_5 35 NO_6 10 N.C. 36 COM_6 11 COM_7 37 N.C. 12 NO_7 38 NO_8 13 N.C. 39 COM_8 14 COM_9 40 N.C. 15 NO_9 41 NO_10 16 N.C. 42 COM_10 17 COM_11 43 N.C. 18 NO_11 44 NO_12 19 N.C. 45 COM_12 20 COM_13 46 N.C. 21 NO_13 47 NO_14 22 N.C. 48 COM_14 23 COM_15 49 N.C. 24 NO_15 50 N.C. 25 N.C. 51 GND1 26 NO_0 52 GND2 1.13 Filler Card Filler cards are designed to occupy empty multiservice and AIC-I slots in the Cisco ONS 15454 (Slots 1–6, 9, and 12 – 17). The filler card cannot operate in the XC slots (Slots 8 and 10) or TCC slots (7 and 11). When installed, the filler card aids in maintaining proper air flow and EMI requirements. Note There are two types of filler cards, a detectable version (Cisco P/N 15454-FILLER) and a non-detectable version (Cisco P/N 15454-BLANK). The detectable card has the label FILLER on the faceplate. The non-detectable card has no faceplate label. In Software Release 6.0 and greater, the former card is detectable through CTC when installed in the ONS 15454 shelf. Figure 1-40 shows the faceplate of the detectable filler card. The filler cards have no card-level LED indicators. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-61 Chapter 1 Shelf and Backplane Hardware 1.14 Fan-Tray Assembly Figure 1-40 Detectable Filler Card Faceplate 124234 FILLER 1.14 Fan-Tray Assembly The fan-tray assembly is located at the bottom of the ONS 15454 bay assembly. The fan tray is a removable drawer that holds fans and fan-control circuitry for the ONS 15454. The front door can be left in place or removed before installing the fan-tray assembly. After you install the fan tray, you should only need to access it if a fan failure occurs or if you need to replace or clean the fan-tray air filter. Cisco ONS 15454 Reference Manual, R8.5.x 1-62 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.14.1 Fan Tray Units for ONS 15454 Cards The front of the fan-tray assembly has an LCD screen that provides slot- and port-level information for all ONS 15454 card slots, including the number of Critical, Major, and Minor alarms. For optical cards, you can use the LCD to determine if a port is in working or protect mode and is active or standby. The LCD also tells you whether the software load is SONET or SDH and the software version number. Note Caution The 15454-SA-ANSI or 15454-SA-HD shelf assembly and 15454-FTA3 or 15454-CC-FTA fan-tray assembly are required with any ONS 15454 that has XC10G or XC-VXC-10G cards. The 15454-FTA3-T fan-tray assembly can only be installed in ONS 15454 Release 3.1 and later shelf assemblies (15454-SA-ANSI, P/N: 800-19857; 15454-SA-HD, P/N: 800-24848). The fan-tray assembly has a pin that prevents it from being installed in ONS 15454 shelf assemblies released before ONS 15454 Release 3.1 (15454-SA-NEBS3E, 15454-SA-NEBS3, and 15454-SA-R1, P/N: 800-07149). Equipment damage can result from attempting to install the 15454-FTA3 in a noncompatible shelf assembly. Note 15454-CC-FTA is compatible with Software Release 2.2.2 and greater and shelf assemblies 15454-SA-HD and 15454-SA-ANSI. Note The 15454-FTA3 is not I-temp compliant. To obtain an I-temp tray, install the 15454-FTA3-T or 15454-CC-FTA fan-tray assembly in an ONS 15454 Release 3.1 shelf assembly (15454-SA-ANSI or 15454-SA-HD). However, do not install the ONS 15454 XC10G cross-connect cards with the 15454-FTA2 fan-tray assembly. 1.14.1 Fan Tray Units for ONS 15454 Cards Table 1-27 lists the applicable fan tray units supported for ONS 15454 cards in Release 8.5: Table 1-27 Fan Tray Units for ONS 15454 Cards ONS 15454 Cards 15454E-FTA-48V (ETSI shelf) /15454-FTA3-T(ANSI shelf) 15454E-CC-FTA (ETSI shelf)/ 15454-CC-FTA (ANSI shelf) TCC2/TCC2P Yes Yes XCVT Yes Yes XC10G Yes Yes XC-VXC-10G Yes Yes AIC-I Yes Yes EC1-12 Yes Yes DS1-14 Yes Yes DS1N-14 Yes Yes DS1/E1-56 Yes Yes DS3-12 Yes Yes DS3N-12 Yes Yes Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-63 Chapter 1 Shelf and Backplane Hardware 1.14.1 Fan Tray Units for ONS 15454 Cards Table 1-27 Fan Tray Units for ONS 15454 Cards ONS 15454 Cards 15454E-FTA-48V (ETSI shelf) /15454-FTA3-T(ANSI shelf) 15454E-CC-FTA (ETSI shelf)/ 15454-CC-FTA (ANSI shelf) DS3/EC1-48 Yes Yes DS3i-N-12 Yes Yes DS3-12E Yes Yes DS3N-12E Yes Yes DS3XM-6 Yes Yes DS3XM-12 Yes Yes OC3 IR 4 SH 1310 Yes Yes OC3 IR 4/ STM1 SH 1310 Yes Yes OC3 IR/ STM1 SH 1310-8 Yes Yes OC12 IR 1310 Yes Yes OC12 IR/STM4 SH 1310 Yes Yes OC12 LR 1310 Yes Yes OC12 LR/STM4 LH 1310 Yes Yes OC12 LR 1550 Yes Yes OC12 LR/STM4 LH 1550 Yes Yes OC12 IR/STM4 SH 1310-4 Yes Yes OC48 IR 1310 Yes Yes OC48 LR 1550 Yes Yes OC48 IR/STM16 SH AS 1310 Yes Yes OC48 LR/STM16 LH AS 1550 Yes Yes OC48 ELR/STM16 EH 100 GHz Yes Yes OC48 ELR 200 GHz Yes Yes OC192 SR/STM64 IO 1310 Yes Yes OC192 IR/STM64 SH 1550 Yes Yes OC192 LR/STM64 LH 1550 Yes Yes OC192 LR/ STM64 LH ITU 15xx.xx Yes Yes 15454_MRC-12 Yes Yes MRC-2.5G-4 Yes Yes OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Yes Yes E100T-12 Yes Yes E100T-G Yes Yes E1000-2 Yes Yes E1000-2-G Yes Yes Cisco ONS 15454 Reference Manual, R8.5.x 1-64 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.14.2 Fan Speed Table 1-27 Fan Tray Units for ONS 15454 Cards ONS 15454 Cards 15454E-FTA-48V (ETSI shelf) /15454-FTA3-T(ANSI shelf) 15454E-CC-FTA (ETSI shelf)/ 15454-CC-FTA (ANSI shelf) G1000-4 Yes Yes G1K-4 Yes Yes M100T-12 Yes Yes M100X-8 Yes Yes ML1000-2 Yes Yes ML-MR-10 No Yes CE-100T-8 Yes Yes CE-MR-10 No Yes CE-1000-4 Yes Yes FC_MR-4 Yes Yes 1.14.2 Fan Speed Fan speed is controlled by TCC2/TCC2P card temperature sensors. The sensors measure the input air temperature at the fan-tray assembly. Fan speed options are low, medium, and high. If the TCC2/TCC2P card fails, the fans automatically shift to high speed. The temperature measured by the TCC/TCC2P2 sensors is displayed on the LCD screen. 1.14.3 Fan Failure If one or more fans fail on the fan-tray assembly, replace the entire assembly. You cannot replace individual fans. The red Fan Fail LED on the front of the fan tray illuminates when one or more fans fail. For fan tray replacement instructions, refer to the Cisco ONS 15454 Troubleshooting Guide. The red Fan Fail LED clears after you install a working fan tray. Caution As with the FTA3, the 15454-CC-FTA Fan Fail LED on the front of the fan-tray assembly illuminates when one or more fans fail to indicate that a fan-tray assembly or AIP replacement is required. But the Fan Fail LED on the 15454-CC-FTA will also illuminate when only one power source is connected to the chassis, and or any fuse blows. In such conditions, the Fan Alarm is triggered and the fans run at maximum speed. 1.14.4 Air Filter The ONS 15454 contains a reusable air filter; Model 15454-FTF2, that is installed either beneath the fan-tray assembly or in the optional external filter brackets. Earlier versions of the ONS 15454 used a disposable air filter that is installed beneath the fan-tray assembly only. However, the reusable air filter is backward compatible. The reusable filter is made of a gray, open-cell, polyurethane foam that is specially coated to provide fire and fungi resistance. All versions of the ONS 15454 can use the reusable air filter. Spare filters should be kept in stock. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-65 Chapter 1 Shelf and Backplane Hardware 1.14.5 Pilot Fuse Caution Do not operate an ONS 15454 without the mandatory fan-tray air filter. Caution Inspect the air filter every 30 days, and clean the filter every three to six months. Replace the air filter every two to three years. Avoid cleaning the air filter with harsh cleaning agents or solvents. Refer to the Cisco ONS 15454 Troubleshooting Guide for information about cleaning and maintaining the fan-tray air filter. 1.14.5 Pilot Fuse The Pilot Fuse in the Fan tray assembly allows you to blow a low rate fuse when the main fuse of the lower power battery is not installed in the equipment. CC-FTAs 15454-CC-FTA 800-27558-01 and 15454-CC-FTA 800-27561-01 can automatically generate an electrical pulse (without external commands) at power on and about every 25-35 minutes in order to drain extra current from both the batteries. The amount of current and the duration of the pulse that the CC-FTA can generate, is suitable to blow the fuses listed in the Table 1-28. Similar to CC-FTA, 15454-FTA3-T 800-23907-01 and 800-23907-05 can also operate the pilot fuses mentioned in Table 1-28 when the main fuse is missing. Unlike CC-FTA, FTA3-T alternatively drains the current from the two batteries every 50-100 msec to feed the fans. Table 1-28 Pilot Fuse Ratings Type of Fuse Current rating Bussmann GMT-18/100A 18/100A Bussmann GMT-1/4A 1/4A Bussmann 70E 18/100A Bussmann 70F 1/4A This is accomplished in the I-temp range (-40°C to +65°C) in either of these conditions: • When the lower power battery is in the 43.0V to 60.0V range and the higher power battery is more than 1V greater than the lower power battery (or) • When the lower power battery is in the 40.0V to 60.0V range and the difference between the two batteries does not exceed 0.5V. 1.15 Power and Ground Description Ground the equipment according to Telcordia standards or local practices. Cisco recommends the following wiring conventions, but customer conventions prevail: • Red wire for battery connections (–48 VDC) • Black wire for battery return connections (0 VDC) • The battery return connection is treated as DC-I, as defined in GR-1089-CORE, issue 3. Cisco ONS 15454 Reference Manual, R8.5.x 1-66 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.16 Alarm, Timing, LAN, and Craft Pin Connections The ONS 15454 has redundant –48 VDC #8 power terminals on the shelf-assembly backplane. The terminals are labeled BAT1, RET1, BAT2, and RET2 and are located on the lower section of the backplane behind a clear plastic cover. To install redundant power feeds, use four power cables and one ground cable. For a single power feed, only two power cables (#10 AWG, 2.588 mm² [0.1018 inch], copper conductor, 194°F [90°C]) and one ground cable (#6 AWG, 4.115 mm² [0.162 inch]) are required. Use a conductor with low impedance to ensure circuit overcurrent protection. However, the conductor must have the capability to safely conduct any faulty current that might be imposed. The existing ground post is a #10-32 bolt. The nut provided for a field connection is also a #10 AWG (2.588 mm² [0.1018 inch]), with an integral lock washer. The lug must be a dual-hole type and rated to accept the #6 AWG (4.115 mm² [0.162 inch]) cable. Two posts are provided on the Cisco ONS 15454 to accommodate the dual-hole lug. Figure 1-41 shows the location of the ground posts. Figure 1-41 Ground Posts on the ONS 15454 Backplane FRAME GROUND 61852 Attach #6 AWG 1.16 Alarm, Timing, LAN, and Craft Pin Connections Caution Always use the supplied ESD wristband when working with a powered ONS 15454. Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly. The ONS 15454 has a backplane pin field located at the bottom of the backplane. The backplane pin field provides 0.045 square inch (29 mm2) wire-wrap pins for enabling external alarms, timing input and output, and craft interface terminals. This section describes the backplane pin field and the pin assignments for the field. Figure 1-42 shows the wire-wrap pins on the backplane pin field. Beneath each wire-wrap pin is a frame ground pin. Frame ground pins are labeled FG1, FG2, FG3, etc. Install the ground shield of the cables connected to the backplane to the ground pin that corresponds to the pin field used. Note The AIC-I requires a shelf assembly running Software Release 3.4.0 or later. The backplane of the ANSI shelf contains a wire-wrap field with pin assignment according to the layout in Figure 1-42. The shelf assembly might be an existing shelf that has been upgraded to R3.4 or later. In this case the backplane pin labeling appears as indicated in Figure 1-43 on page 1-69. But you must use the pin assignments provided by the AIC-I as shown in Figure 1-42. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-67 Chapter 1 Shelf and Backplane Hardware 1.16 Alarm, Timing, LAN, and Craft Pin Connections A ONS 15454 Backplane Pinouts (Release 3.4 or Later) B A B A B 1 1 2 2 2 2 3 3 3 3 5 4 4 4 4 6 BITS LAN FG2 Pin A1 B ACO A B A FG3 Function BITS Output 2 negative (–) B1 BITS Output 2 positive (+) A2 BITS Input 2 negative (–) FG5 B A 1 11 8 2 2 2 2 12 9 3 3 3 3 10 4 4 4 4 MODEM CRAFT Pin FG8 FG7 LOCAL ALARMS FG9 AUD FG10 A3/A15 Normally open output pair number 3 B3/B15 N/O B2/B14 B3 BITS Output 1 positive (+) A4 BITS Input 1 negative (–) A4/A16 Normally open output pair number 4 B4 BITS Input 1 positive (+) B4/B16 B1 RJ-45 pin 3 RX+ A2 RJ-45 pin 2 TX– ACO CRAFT RJ-45 pin 1 TX+ Connecting to a PC/Workstation or router RJ-45 pin 2 RX– B1 RJ-45 pin 1 RX+ A2 RJ-45 pin 6 TX– B2 A1 RJ-45 pin 3 TX+ ENVIR ALARMS B1 IN A2 B2 A3 B3 A4 B4 A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 A10 B10 A11 B11 A12 B12 Alarm input pair number 1: Reports closure on connected wires. Alarm input pair number 4: Reports closure on connected wires. Alarm input pair number 5: Reports closure on connected wires. A1 Receive (PC pin #2) Transmit (PC pin #3) A3 Ground (PC pin #5) LOCAL A1 ALARMS B1 AUD A2 (Audible) B2 N/O A3 B3 A4 B4 LOCAL A1 ALARMS B1 VIS (Visual) A2 B2 N/O A3 B3 Alarm input pair number 6: Reports closure on connected wires. Alarm input pair number 7: Reports closure on connected wires. Normally open ACO pair A2 A4 Alarm input pair number 2: Reports closure on connected wires. Alarm input pair number 3: Reports closure on connected wires. A1 If you are using an AIC-I card, contacts provisioned as OUT are 1-4. Contacts provisioned as IN are 13-16. B1 B2 A1 FG12 Function BITS Input 2 positive (+) RJ-45 pin 6 RX– FG11 A1/A13 Normally open output pair number 1 ENVIR ALARMS B1/B13 IN/OUT A2/A14 Normally open output pair number 2 BITS Output 1 negative (–) Connecting to a hub, or switch B IN VIS IN A3 A1 A 1 B2 LAN B 1 FG6 Field A A 1 IN IN/OUT FG4 B 7 ENVIRONMENTAL ALARMS IN BITS A 1 FG1 Field B A 1 A4 B4 DTR (PC pin #4) Alarm output pair number 1: Remote audible alarm. Alarm output pair number 2: Critical audible alarm. Alarm output pair number 3: Major audible alarm. Alarm output pair number 4: Minor audible alarm. Alarm output pair number 1: Remote visual alarm. Alarm output pair number 2: Critical visual alarm. Alarm output pair number 3: Major visual alarm. Alarm output pair number 4: Minor visual alarm. 83020 Figure 1-42 Alarm input pair number 8: Reports closure on connected wires. Alarm input pair number 9: Reports closure on connected wires. Alarm input pair number 10: Reports closure on connected wires. Alarm input pair number 11: Reports closure on connected wires. Alarm input pair number 12: Reports closure on connected wires. Cisco ONS 15454 Reference Manual, R8.5.x 1-68 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.16.1 Alarm Contact Connections A ONS 15454 Backplane Pinouts B A B A B A B A B A B A B A A B A B A 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 BITS 4 4 LAN ENVIR 4 ALARMS IN FG1 FG2 Field BITS FG3 Pin A1 4 4 ACO X . 25 Function BITS Output 2 negative (-) BITS Output 2 positive (+) BITS Input 2 negative (-) B2 BITS Input 2 positive (+) FG6 FG7 Field Pin A1 ENVIR ALARMS B1 OUT A2 N/O A3 BITS Output 1 negative (-) A3 BITS Output 1 positive (+) B3 A4 BITS Input 1 negative (-) A4 B4 BITS Input 1 positive (+) B4 Connecting to a hub, or switch RJ-45 pin 6 RX- B1 RJ-45 pin 3 RX+ A2 RJ-45 pin 2 TX- ACO CRAFT RJ-45 pin 1 TX+ Connecting to a PC/Workstation or router RJ-45 pin 2 RX- B1 RJ-45 pin 1 RX+ A2 RJ-45 pin 6 TX- B2 A1 RJ-45 pin 3 TX+ B2 A3 B3 A4 B4 Alarm input pair number 1: Reports closure on connected wires. Alarm input pair number 4: Reports closure on connected wires. A1 A1 AUD FG10 FG11 FG12 Function Normally open output pair number 1 Normally open output pair number 2 Normally open output pair number 3 Normally open output pair number 4 Normally open ACO pair Transmit (PC pin #3) A3 Ground (PC pin #5) A4 B3 A4 B4 LOCAL A1 ALARMS B1 VIS (Visual) A2 B2 N/O Receive (PC pin #2) A2 LOCAL A1 ALARMS B1 AUD A2 (Audible) B2 N/O A3 Alarm input pair number 2: Reports closure on connected wires. Alarm input pair number 3: Reports closure on connected wires. 4 B1 B2 A1 FG9 2 TBOS B2 B3 A1 FG8 1 ALARMS VIS FG5 B1 ENVIR ALARMS B1 IN A2 CRAFT LOCAL OUT FG4 A2 LAN 4 MODEM B A3 B3 A4 B4 DTR (PC pin #4) Alarm output pair number 1: Remote audible alarm. Alarm output pair number 2: Critical audible alarm. Alarm output pair number 3: Major audible alarm. Alarm output pair number 4: Minor audible alarm. Alarm output pair number 1: Remote visual alarm. Alarm output pair number 2: Critical visual alarm. Alarm output pair number 3: Major visual alarm. Alarm output pair number 4: Minor visual alarm. 38533 Figure 1-43 1.16.1 Alarm Contact Connections The alarm pin field supports up to 17 alarm contacts, including four audible alarms, four visual alarms, one alarm cutoff (ACO), and four user-definable alarm input and output contacts. Audible alarm contacts are in the LOCAL ALARM AUD pin field and visual contacts are in the LOCAL ALARM VIS pin field. Both of these alarms are in the LOCAL ALARMS category. User-definable contacts are in the ENVIR ALARM IN (external alarm) and ENVIR ALARM OUT (external control) pin fields. These alarms are in the ENVIR ALARMS category; you must have the AIC-I card installed to use the ENVIR ALARMS. Alarm contacts are Normally Open (N/O), meaning that the system closes the alarm contacts when the corresponding alarm conditions are present. Each alarm contact consists of two wire-wrap pins on the shelf assembly backplane. Visual and audible alarm contacts are classified as critical, major, minor, and remote. Figure 1-43 shows alarm pin assignments. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-69 Chapter 1 Shelf and Backplane Hardware 1.16.2 Timing Connections Visual and audible alarms are typically wired to trigger an alarm light or bell at a central alarm collection point when the corresponding contacts are closed. You can use the Alarm Cutoff pins to activate a remote ACO for audible alarms. You can also activate the ACO function by pressing the ACO button on the TCC2/TCC2P card faceplate. The ACO function clears all audible alarm indications. After clearing the audible alarm indication, the alarm is still present and viewable in the Alarms tab in CTC. For more information, see the “2.7.2 External Alarms and Controls” section on page 2-30. 1.16.2 Timing Connections The ONS 15454 backplane supports two building integrated timing supply (BITS) clock pin fields. The first four BITS pins, rows 3 and 4, support output and input from the first external timing device. The last four BITS pins, rows 1 and 2, perform the identical functions for the second external timing device. Table 1-29 lists the pin assignments for the BITS timing pin fields. Note For timing connection, use 100-ohm shielded BITS clock cable pair #22 or #24 AWG (0.51 mm² [0.020 inch] or 0.64 mm² [0.0252 inch]), twisted-pair T1-type. Table 1-29 BITS External Timing Pin Assignments External Device Contact Tip and Ring Function First external device A3 (BITS 1 Out) Primary ring (–) Output to external device B3 (BITS 1 Out) Primary tip (+) Output to external device A4 (BITS 1 In) Secondary ring (–) Input from external device B4 (BITS 1 In) Secondary tip (+) Input from external device A1 (BITS 2 Out) Primary ring (–) Output to external device B1 (BITS 2 Out) Primary tip (+) Output to external device A2 (BITS 2 In) Secondary ring (–) Input from external device B2 (BITS 2 In) Secondary tip (+) Input from external device Second external device Note Refer to Telcordia SR-NWT-002224 for rules about provisioning timing references. For more information, see Chapter 10, “Timing.” 1.16.3 LAN Connections Use the LAN pins on the ONS 15454 backplane to connect the ONS 15454 to a workstation or Ethernet LAN, or to a LAN modem for remote access to the node. You can also use the LAN port on the TCC2/TCC2P card faceplate to connect a workstation or to connect the ONS 15454 to the network. Table 1-30 shows the LAN pin assignments. Before you can connect an ONS 15454 to other ONS 15454s or to a LAN, you must change the default IP address that is shipped with each ONS 15454 (192.1.0.2). Cisco ONS 15454 Reference Manual, R8.5.x 1-70 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.16.4 TL1 Craft Interface Installation Table 1-30 LAN Pin Assignments Pin Field Backplane Pins RJ-45 Pins LAN 1 Connecting to data circuit-terminating equipment (DCE1, a hub or switch) B2 1 A2 2 B1 3 A1 6 B1 1 A1 2 B2 3 A2 6 LAN 1 Connecting to data terminal equipment (DTE) (a PC/workstation or router) 1. The Cisco ONS 15454 is DCE. 1.16.4 TL1 Craft Interface Installation You can use the craft pins on the ONS 15454 backplane or the EIA/TIA-232 port on the TCC2/TCC2P card faceplate to create a VT100 emulation window to serve as a TL1 craft interface to the ONS 15454. Use a straight-through cable to connect to the EIA/TIA-232 port. Table 1-31 shows the pin assignments for the CRAFT pin field. Note You cannot use the craft backplane pins and the EIA/TIA-232 port on the TCC2/TCC2P card simultaneously. Note To use the serial port craft interface wire-wrap pins on the backplane, the DTR signal line on the backplane port wire-wrap pin must be connected and active. Table 1-31 Craft Interface Pin Assignments Pin Field Contact Function Craft A1 Receive A2 Transmit A3 Ground A4 DTR 1.17 Cards and Slots ONS 15454 cards have electrical plugs at the back that plug into electrical connectors on the shelfassembly backplane. When the ejectors are fully closed, the card plugs into the assembly backplane. Figure 1-44 shows card installation. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-71 Chapter 1 Shelf and Backplane Hardware 1.17.1 Card Slot Requirements Installing Cards in the ONS 15454 39391 Figure 1-44 FAN FAIL CR IT MAJ MIN Ejector Guide rail 1.17.1 Card Slot Requirements The ONS 15454 shelf assembly has 17 card slots numbered sequentially from left to right. Slots 1 to 6 and 12 to 17 are multiservice slots that are used for electrical, optical, and Ethernet cards (traffic cards). Card compatibility depends on the EIA, protection scheme, and cross-connect card type used in the shelf. Refer to the “3.1.2 Card Compatibility” section on page 3-3 for more detailed compatibility information. Slots 7 and 11 are dedicated to TCC2/TCC2P cards. Slots 8 and 10 are dedicated to cross-connect (XCVT, XC10G, and XC-VXC-10G) cards. Slot 9 is reserved for the optional AIC-I card. Slots 3 and 15 can also host electrical cards that are used for 1:N protection. (See the “7.1 Electrical Card Protection” section on page 7-1 for a list of electrical cards that can operate as protect cards.) Caution Do not operate the ONS 15454 with a single TCC2/TCC2P card or a single XCVT/XC10G/XC-VXC-10G card installed. Always operate the shelf assembly with one working and one protect card of the same type. Shelf assembly slots have symbols indicating the type of cards that you can install in them. Each ONS 15454 card has a corresponding symbol. The symbol on the card must match the symbol on the slot. Table 1-32 shows the slot and card symbol definitions. Cisco ONS 15454 Reference Manual, R8.5.x 1-72 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.17.1 Card Slot Requirements Note Protection schemes and EIA types can affect slot compatibility. Table 1-32 Symbol Color/Shape Slot and Card Symbols Definition Orange/Circle Slots 1 to 6 and 12 to 17. Only install ONS 15454 cards with a circle symbol on the faceplate. Blue/Triangle Slots 5, 6, 12, and 13. Only install ONS 15454 cards with circle or a triangle symbol on the faceplate. Purple/Square TCC2/TCC2P slot, Slots 7 and 11. Only install ONS 15454 cards with a square symbol on the faceplate. Green/Cross Cross-connect (XCVT/XC10G) slot, Slots 8 and 10. Only install ONS 15454 cards with a cross symbol on the faceplate. Red/P Protection slot in 1:N protection schemes. Red/Diamond AIC-I slot (Slot 9). Only install ONS 15454 cards with a diamond symbol on the faceplate. Gold/Star Slots 1 to 4 and 14 to 17. Only install ONS 15454 cards with a star symbol on the faceplate. Blue/Hexagon (Only used with the 15454-SA-HD shelf assembly) Slots 3 and 15. Only install ONS 15454 cards with a blue hexagon symbol on the faceplate. Table 1-33 lists the number of ports, line rates, connector options, and connector locations for ONS 15454 optical, electrical, and Ethernet cards. Table 1-33 Card Ports, Line Rates, and Connectors Connector Location Card Ports Line Rate per Port Connector Types DS1-14 14 1.544 Mbps SMB w/wire wrap adapter, AMP Champ connector Backplane DS1N-14 14 1.544 Mbps SMB w/wire wrap1 adapter, AMP Champ connector — DS1/E1-56 56 1.544 Mbps SMB w/wire wrap2 adapter, AMP Champ connector — DS3-12 12 44.736 Mbps SMB or BNC1 Backplane 44.736 Mbps SMB or BNC 1 — SMB or BNC 1 Backplane SMB or BNC 1 — SMB or BNC 1 Backplane SMB or BNC 1 Backplane DS3N-12 DS3-12E DS3N-12E DS3XM-6 DS3XM-12 12 12 12 6 12 44.736 Mbps 44.736 Mbps 44.736 Mbps 89.472 Mbps Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-73 Chapter 1 Shelf and Backplane Hardware 1.17.1 Card Slot Requirements Table 1-33 Card Ports, Line Rates, and Connectors (continued) Card Ports Line Rate per Port Connector Types Connector Location DS3/EC1-48 48 2.147 Gbps SMB or BNC Backplane 1 EC1-12 12 51.84 Mbps SMB or BNC E100T-12 12 100 Mbps RJ-45 Faceplate E1000-2 2 1 Gbps SC (GBIC) Faceplate E100T-G 12 100 Mbps RJ-45 Faceplate E1000-2-G 2 1 Gbps SC (GBIC) Faceplate G1K-4 4 1 Gbps SC (GBIC) Faceplate ML100T-12 12 100 Mbps RJ-45 Faceplate ML100X-8 8 100 Mbps SC (SFP) Faceplate ML1000-2 2 1 Gbps LC (SFP) Faceplate ML-MR-10 10 10/100/1000 Mbps LC (SFP), Copper (SFP)-RJ45 Faceplate CE-100T-8 8 10/100/1000 Mbps LC (SFP), Copper (SFP)-RJ45 Faceplate CE-MR-10 10 1000 Mbps LC (SFP), Copper (SFP)-RJ45 Faceplate OC-3 IR 4 155.52 Mbps (STS-3) SC Faceplate OC3 IR/STM4 SH 1310-8 8 155.52 Mbps (STS-3) LC Faceplate OC-12/STM4-4 (IR/LR) 4 622.08 Mbps (STS-12) SC Faceplate OC-12 (IR/LR) 1 622.08 Mbps (STS-12) SC Faceplate OC-48 (IR/LR/ELR) 1 2488.32 Mbps (STS-48) SC Faceplate OC-48 AS (IR/LR) 1 2488.32 Mbps (STS-48) SC Faceplate OC-48 ELR 1 (100GHz, 200GHz) 2488.32 Mbps (STS-48) SC Faceplate OC192 SR/STM64 IO 1310 1 9.95 Gbps (STS-192) SC Faceplate OC192 IR/STM64 SH 1550 1 9.95 Gbps (STS-192) SC Faceplate OC192 LR/STM64 LH 1550 1 9.95 Gbps (STS-192) SC Faceplate OC192 LR/STM64 LH ITU 15xx.xx 1 9.95 Gbps (STS-192) SC Faceplate FC_MR-4 4 (only 2 available in R4.6) 1.0625 Gbps SC Faceplate Backplane Cisco ONS 15454 Reference Manual, R8.5.x 1-74 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.17.2 Card Replacement Table 1-33 Card Ports, Line Rates, and Connectors (continued) Card Ports Line Rate per Port Connector Types Connector Location 15454_MRC-12 12 Up to 2488.32 Mbps (STM-48), depending on SFP LC Faceplate MRC-2.5G-4 4 Up to 2488.32 Mbps (STS-48), depending on SFP LC Faceplate 9.95 Gbps (OC-192) LC Faceplate OC192SR1/STM64 1 IO Short Reach/ OC192/STM64 Any Reach3 1. When used as a protect card, the card does not have a physical external connection. The protect card connects to the working card(s) through the backplane and becomes active when the working card fails. The protect card then uses the physical connection of the failed card. 2. When used as a protect card, the card does not have a physical external connection. The protect card connects to the working card(s) through the backplane and becomes active when the working card fails. The protect card then uses the physical connection of the failed card. 3. These cards are designated as OC192-XFP in CTC. 1.17.2 Card Replacement To replace an ONS 15454 card with another card of the same type, you do not need to make any changes to the database; remove the old card and replace it with a new card. To replace a card with a card of a different type, physically remove the card and replace it with the new card, then delete the original card from CTC. For specifics, refer to the “Install Cards and Fiber-Optic Cable” chapter in the Cisco ONS 15454 Procedure Guide. Caution Removing any active card from the ONS 15454 can result in traffic interruption. Use caution when replacing cards and verify that only inactive or standby cards are being replaced. If the active card needs to be replaced, switch it to standby prior to removing the card from the node. For traffic switching procedures, refer to the “Maintain the Node” chapter in the Cisco ONS 15454 Procedure Guide. Note An improper removal (IMPROPRMVL) alarm is raised whenever a card is removed and reinserted (reseated) is performed, unless the card is deleted in CTC first. The alarm clears after the card replacement is complete. Note In a path protection configuration, pulling the active XCVT/XC10G without a lockout causes path protection circuits to switch. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-75 Chapter 1 Shelf and Backplane Hardware 1.18 Software and Hardware Compatibility 1.18 Software and Hardware Compatibility Table 1-34 shows ONS 15454 software and hardware compatibility for nodes configured with XC or XCVT cards for Releases 4.6, 4.7, 5.0, 6.0, 7.0, 7.2, 8.0, and 8.5. For software compatibility for a specific card, refer to the following URL: http://cisco.com/en/US/products/hw/optical/ps2006/prod_eol_notices_list.html Note Partially supported : Once a card has been through End Of Life(EOL), new features would not be supported for the card. However bug fixes would be available. Note The TCC and TCC+ cards are only supported up to Release 4.x. Table 1-34 ONS 15454 Software and Hardware Compatibility—XC1 and XCVT Configurations Hardware Shelf Assembly2 4.6.0x (4.6) TCC2 All TCC2P 5.0.0x (5.0) 6.0.0x (6.0) 7.0.0x (7.0) 7.2.0x (7.2) 8.0.0x (8.0) 8.5.0x (8.5) Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible AIC All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible AIC-I All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible DS1-14 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible DS1N-14 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible DS1/E1-56 SA-HD Not supported Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible DS3-123 All Fully Fully compatible compatible Partially supported Partially supported Partially supported Partially supported Partially supported DS3N-12 All Fully Fully compatible compatible Partially supported Partially supported Partially supported Partially supported Partially supported DS3i-N-12 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible DS3-12E All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible DS3N-12E All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible DS3XM-6 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible Not supported Cisco ONS 15454 Reference Manual, R8.5.x 1-76 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.18 Software and Hardware Compatibility Table 1-34 ONS 15454 Software and Hardware Compatibility—XC1 and XCVT Configurations (continued) Hardware Shelf Assembly2 4.6.0x (4.6) 5.0.0x (5.0) 6.0.0x (6.0) 7.0.0x (7.0) 7.2.0x (7.2) 8.0.0x (8.0) 8.5.0x (8.5) Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible DS3XM-12 SA-HD and Not SA-ANSI supported EC1-12 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible E100T-12 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible E1000-2 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible E100T-12-G All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible E1000-2-G All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible G1000-4 All Fully Fully compatible compatible Partially supported Partially supported Partially supported Partially supported Partially supported G1K-4 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible ML100T-12 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible ML1000-2 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible ML100X-8 All Not supported Not supported Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible ML-MR-104 SA-HD and Not SA-ANSI supported Not supported Not supported Not supported Not supported Not supported Fully compatible CE-MR-10 SA-HD and Not SA-ANSI supported Not supported Not supported Not supported Not supported Not supported Fully compatible CE-100T-8 All Fully Fully Fully Fully Fully Fully Compatible Compatible Compatible Compatible Compatible Compatibl e CE-1000-4 SA-HD and Not SA-ANSI Supported OC3 IR 4/STM1 SH 1310 All Not Supported Not Supported Not Supported Fully Fully Fully Fully Compatible Compatible Compatible Compatibl e Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible OC3IR/STM1S All H 1310-8 Not supported Not supported Not supported Not supported Not supported Not supported OC12 IR 1310 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible OC12 IR/4 1310 All Not supported Not supported Not supported Not supported Not supported Not supported Not supported Not supported Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-77 Chapter 1 Shelf and Backplane Hardware 1.18 Software and Hardware Compatibility Table 1-34 ONS 15454 Software and Hardware Compatibility—XC1 and XCVT Configurations (continued) Hardware Shelf Assembly2 4.6.0x (4.6) 5.0.0x (5.0) 6.0.0x (6.0) 7.0.0x (7.0) 7.2.0x (7.2) 8.0.0x (8.0) 8.5.0x (8.5) OC12 LR 1310 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible OC12 LR 1550 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible OC48 IR 1310 All Fully Fully compatible compatible Fully compatible Partially supported Partially supported Not supported Partially supported OC48 LR 1550 All Fully Fully compatible compatible Fully compatible Partially supported Partially supported Partially supported Partially supported OC48 ELR DWDM All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible OC48 IR/STM16 SH AS 1310 All Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible All OC48 LR/STM16 LH AS 1550 Fully Fully compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible OC192 SR/STM64 IO 1310 SA-HD and Not SA-ANSI supported Not supported Not supported Not supported Not supported Not supported Not supported OC192 IR/STM64 SH 1550 SA-HD and Not SA-ANSI supported Not supported Not supported Not supported Not supported Not supported Not supported OC192 SA-HD and Not LH/STM64 LH SA-ANSI supported 1550 Not supported Not supported Not supported Not supported Not supported Not supported OC192 SA-HD and Not LR/STM64 LH SA-ANSI supported ITU 15xx.xx Not supported Not supported Not supported Not supported Not supported Not supported FC_MR-4 SA-HD and Fully Fully SA-ANSI compatible compatible Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible MRC-12 5 All Not supported Not supported Fully compatible Fully compatible Fully compatible Fully compatible Fully compatible MRC-2.5G-44 All Not supported Not supported Not supported Not supported Not supported Fully compatible Fully compatible OC192SR1/ST SA-HD and Not SA-ANSI supported M64IO Short Reach/ OC192/STM64 Any Reach6 Not supported Not supported Not supported Not supported Not supported Not supported 1. The XC card does not support features new to Release 5.0 and greater. 2. The shelf assemblies supported are 15454-SA-HD, 15454-SA-ANSI, and 15454-NEBS3E. 3. DS3 card having the part number 87-31-0001 does not work in Cisco ONS 15454 R8.0 and later. 4. ML-MR-10 and CE-MR-10 cards are not supported on XCVT. Cisco ONS 15454 Reference Manual, R8.5.x 1-78 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.18 Software and Hardware Compatibility 5. Slots 1 to 4 and 14 to 17 give a total bandwidth of up to 622 Mb/s. Slots 5, 6 , 12 , and 13 give a total bandwidth of up to 2.5 Gb/s 6. These cards are designated as OC192-XFP in CTC. Table 1-35 shows ONS 15454 software and hardware compatibility for systems configured with XC10G or XC-VXC-10G cards for Releases 4.6, 4.7, 5.0, 6.0, 7.0, 7.2, 8.0, and 8.5. The 15454-SA-ANSI or 15454-SA-HD shelf assembly is required to operate the XC10G or XC-VXC-10G card. XC-VXC-10G is only supported from Release 6.0. Refer to the older ONS 15454 documentation for compatibility with older software releases. Table 1-35 Note Release 4.7 is for MSTP only. The cards supported in Release 4.7 are TCC2, TCC2P, and AIC , AIC-I. Note Partially supported : Once a card has been through End Of Life(EOL), new features would not be supported for the card. However bug fixes would be available. ONS 15454 Software and Hardware Compatibility—XC10G and XC-VXC-10G Configurations Hardware Shelf Assembly1 TCC2 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible TCC2P All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible XC10G SA-HD and SA-ANSI Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible AIC All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible AIC-I All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible DS1-14 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible DS1N-14 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible DS1/E1-56 SA-HD Not supported DS3-122 All Fully Fully Partially compatible compatible supported Partially supported Partially supported Partially supported Partially supported DS3N-12 All Fully Fully Partially compatible compatible supported Partially supported Partially supported Partially supported Partially supported DS3i-N-12 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible DS3-12E All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible DS3N-12E All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible 4.6.0x (4.6) 5.0.0x (5.0) Not supported 6.0.0x (6.0) 7.0.0x (7.0) 7.2.0x (7.2) 8.0.0x (8.0) 8.5.0.x (8.5) Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-79 Chapter 1 Shelf and Backplane Hardware 1.18 Software and Hardware Compatibility Table 1-35 ONS 15454 Software and Hardware Compatibility—XC10G and XC-VXC-10G Configurations (continued) Shelf Assembly1 Hardware 4.6.0x (4.6) 5.0.0x (5.0) SA-HD Not supported Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible DS3XM-6 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible DS3XM-12 SA-HD and SA-ANSI Not supported EC1-12 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible SVC-RAN SA-HD and SA-ANSI Not supported Not supported Not supported Not supported Fully Not compatible supported Not supported E100T SA-HD and SA-ANSI Not supported Not supported Not supported Not supported Not supported Not supported Not supported E1000 SA-HD and SA-ANSI Not supported Not supported Not supported Not supported Not supported Not supported Not supported E100T-12-G All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible E1000-2-G All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible G1000-4 All Fully Fully Partially compatible compatible supported G1K-4 SA-HD and SA-ANSI Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible ML100T-12 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible ML1000-2 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible ML100X-8 All Not supported Not supported Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible ML-MR-10 SA-HD and SA-ANSI Not supported Not supported Not supported Not supported Not supported Not supported Fully compatible CE-MR-10 SA-HD and SA-ANSI Not supported Not supported Not supported Not supported Not supported Not supported Fully compatible CE-100T-8 All Not supported Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible CE-1000-4 SA-HD and SA-ANSI Not supported Not supported OC3 IR 4/STM1 SH 1310 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible DS3/EC1-48 1 OC3IR/STM1SH SA-HD and 1310-8 SA-ANSI 6.0.0x (6.0) 7.0.0x (7.0) 7.2.0x (7.2) 8.0.0x (8.0) 8.5.0.x (8.5) Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible Not supported Partially supported Partially supported Partially supported Partially supported Fully Fully Fully Fully compatible compatible compatible compatible Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible Cisco ONS 15454 Reference Manual, R8.5.x 1-80 78-18106-01 Chapter 1 Shelf and Backplane Hardware 1.18 Software and Hardware Compatibility Table 1-35 ONS 15454 Software and Hardware Compatibility—XC10G and XC-VXC-10G Configurations (continued) Shelf Assembly1 4.6.0x (4.6) OC12/STM4-4 SA-HD and SA-ANSI Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible OC12 IR 1310 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible OC12 LR 1310 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible OC12 LR 1550 All Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible OC48 IR 1310 All Fully Fully Fully Partially compatible compatible compatible supported Partially supported Not supported Partially supported OC48 LR 1550 All Fully Fully Fully Partially compatible compatible compatible supported Partially supported Partially supported Partially supported Hardware 5.0.0x (5.0) 6.0.0x (6.0) 7.0.0x (7.0) 7.2.0x (7.2) 8.0.0x (8.0) 8.5.0.x (8.5) OC48 IR/STM16 SA-HD and SH AS 1310 SA-ANSI Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible OC48 LR/STM16 LH AS 1550 SA-HD and SA-ANSI Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible OC192 SR/STM64 IO 1310 SA-HD and SA-ANSI Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible OC192 IR/STM64 SH 1550 SA-HD and SA-ANSI Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible OC192 LH/STM64 LH 1550 SA-HD and SA-ANSI Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible OC192 LR/STM64 LH ITU 15xx.xx SA-HD and SA-ANSI Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible FC_MR-4 SA-HD and SA-ANSI Fully Fully Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible compatible compatible MRC-12 3 All Not supported Not supported Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible MRC-2.5G-4 All Not supported Not supported Not supported Not supported Not supported Fully Fully Fully Fully Fully compatible compatible compatible compatible compatible OC192SR1/STM SA-HD and 64IO Short SA-ANSI Reach/ OC192/STM64 Any Reach4 Not supported Not supported Fully Fully compatible compatible 1. The shelf assemblies supported are 15454-SA-HD and 15454-SA-ANSI. 2. DS3 card having the part number 87-31-0001 does not work in Cisco ONS 15454 R8.0 and later. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 1-81 Chapter 1 Shelf and Backplane Hardware 1.18 Software and Hardware Compatibility 3. Slots 1 to 4 and 14 to 17 give a total bandwidth of up to 2.5 Gb/s. Slots 5, 6, 12 , and 13 give a total bandwidth of up to 10 Gb/s 4. These cards are designated as OC192-XFP in CTC. If an upgrade is required for compatibility, contact the Cisco Technical Assistance Center (TAC). For contact information, go to http://www.cisco.com/tac. Cisco ONS 15454 Reference Manual, R8.5.x 1-82 78-18106-01 CH A P T E R 2 Common Control Cards Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This chapter describes Cisco ONS 15454 common control card functions. For installation and turn-up procedures, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 2.1 Common Control Card Overview, page 2-1 • 2.2 TCC2 Card, page 2-6 • 2.3 TCC2P Card, page 2-10 • 2.4 XCVT Card, page 2-15 • 2.5 XC10G Card, page 2-19 • 2.6 XC-VXC-10G Card, page 2-23 • 2.7 AIC-I Card, page 2-28 2.1 Common Control Card Overview The card overview section summarizes card functions and compatibility. Each card is marked with a symbol that corresponds to a slot (or slots) on the ONS 15454 shelf assembly. The cards are then installed into slots displaying the same symbols. See the “1.17.1 Card Slot Requirements” section on page 1-72 for a list of slots and symbols. 2.1.1 Cards Summary Table 2-1 lists the common control cards for the Cisco ONS 15454 and summarizes card functions. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-1 Chapter 2 Common Control Cards 2.1.1 Cards Summary Table 2-1 Common Control Card Functions Card Description For Additional Information... TCC2 The Advanced Timing, Communications, and Control See the “2.2 TCC2 Card” section on page 2-6. (TCC2) card is the main processing center for the ONS 15454 and provides system initialization, provisioning, alarm reporting, maintenance, and diagnostics. It has additional features including supply voltage monitoring, support for up to 84 data communications channel/generic communications channel (DCC/GCC) terminations, and an on-card lamp test. TCC2P The Advanced Timing, Communications, and Control See the “2.3 TCC2P Card” section on Plus (TCC2P) card is the main processing center for page 2-10. the ONS 15454 and provides system initialization, provisioning, alarm reporting, maintenance, and diagnostics. It also provides supply voltage monitoring, support for up to 84 DCC/GCC terminations, and an on-card lamp test. This card also has Ethernet security features and 64K composite clock building integrated timing supply (BITS) timing. XCVT The Cross Connect Virtual Tributary (XCVT) card is the central element for switching; it establishes connections and performs time-division switching (TDS). The XCVT can manage STS and Virtual Tributary (VT) circuits up to 48c. XC10G See the “2.5 XC10G Card” section on The 10 Gigabit Cross Connect (XC10G) card is the page 2-19. central element for switching; it establishes connections and performs TDS. The XC10G can manage STS and VT circuits up to 192c. The XC10G allows up to four times the bandwidth of XC and XCVT cards. XC-VXC-10G See the “2.6 XC-VXC-10G Card” section on The 10 Gigabit Cross Connect Virtual page 2-23. Tributary/Virtual Container (XC-VXC-10G) card serves as the switching matrix for the Cisco 15454 ANSI multiservice platform. The module operates as a superset of the XCVT or XC10G cross-connect module. The XC-VXC-10G card provides a maximum of 1152 STS-1 or 384 VC4 cross-connections and supports cards with speeds up to 10 Gbps. AIC-I The Alarm Interface Card–International (AIC-I) provides customer-defined (environmental) alarms with its additional input/output alarm contact closures. It also provides orderwire, user data channels, and supply voltage monitoring. AEP The alarm expansion panel (AEP) board provides See the “1.12 Alarm Expansion Panel” section 48 dry alarm contacts: 32 inputs and 16 outputs. It can on page 1-56 be used with the AIC-I card. See the “2.4 XCVT Card” section on page 2-15. See the “2.7 AIC-I Card” section on page 2-28. Cisco ONS 15454 Reference Manual, R8.5.x 2-2 78-18106-01 Chapter 2 Common Control Cards 2.1.2 Card Compatibility 2.1.2 Card Compatibility Table 2-2 lists the Cisco Transport Controller (CTC) software release compatibility for each common-control card. In the tables below, “Yes” means cards are compatible with the listed software versions. Table cells with dashes mean cards are not compatible with the listed software versions. Table 2-2 Common-Control Card Software Release Compatibility Card R3.3 R3.4 R4.0 R4.1 R4.5 R4.6 R4.7 R5.0 R6.0 R7.0 R7.2 R8.0 TCC+ Yes Yes Yes Yes — — — — — — — — TCC2 — — Yes Yes Yes Yes Yes Yes Yes Yes Yes Y es Yes TCC2P — — Yes Yes Yes Yes Yes Yes Yes 1 Yes 1 Yes 1 Yes 1 R8.5 Yes 1 Yes1 XC Yes Yes Yes Yes — Yes — Yes XCVT Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes XC10G Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes XC-VXC-10G — — — — — — — — Yes Yes Yes Yes Yes AIC Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes AIC-I — Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes AEP — Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 1. The XC card does not support features new to Release 5.0 and later. 2.1.3 Cross-Connect Card Compatibility The following tables list the compatible cross-connect cards for each Cisco ONS 15454 common-control card. The tables are organized according to type of common-control card. In the tables below, “Yes” means cards are compatible with the listed cross-connect card. Table cells with dashes mean cards are not compatible with the listed cross-connect card. Table 2-3 lists the cross-connect card compatibility for each common-control card. Table 2-3 Common-Control Card Cross-Connect Compatibility Card XCVT Card XC10G Card1 XC-VXC-10G Card1 TCC+2 Yes Yes — TCC2 Yes Yes Yes TCC2P Yes Yes Yes 3 3 —3 XC — XCVT Yes —3 —3 XC10G —3 Yes —3 XC-VXC-10G —3 —3 Yes AIC-I Yes Yes Yes — Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-3 Chapter 2 Common Control Cards 2.1.3 Cross-Connect Card Compatibility Table 2-3 Common-Control Card Cross-Connect Compatibility (continued) Card XCVT Card XC10G Card1 XC-VXC-10G Card1 AEP Yes Yes Yes 1. Requires SA-ANSI or SA-HD shelf assembly. 2. The TCC+ is not compatible with Software R4.5 or greater. 3. These cross-connect cards are compatible only during an upgrade. Table 2-4 lists the cross-connect card compatibility for each electrical card. For electrical card software compatiblilty, see Table 3-2 on page 3-3. Note The XC card is compatible with most electrical cards, with the exception of the DS3i-N-12, DS3/EC1-48, DS1/E1-56, and transmux cards, but does not support features new to Release 5.0 and later. Table 2-4 Electrical Card Cross-Connect Compatibility Electrical Card XCVT Card XC10G Card1 XC-VXC-10G Card1 EC1-12 Yes Yes Yes DS1-14 Yes Yes Yes DS1N-14 Yes Yes Yes DS3-12 Yes Yes Yes DS3N-12 Yes Yes Yes DS3-12E Yes Yes Yes DS3N-12E Yes Yes Yes DS3/EC1-48 — Yes Yes DS3XM-6 (Transmux) Yes Yes Yes DS3XM-12 (Transmux) Yes Yes Yes DS3i-N-12 Yes Yes Yes DS1/E1-56 Yes Yes Yes 1. Requires a 15454-SA-ANSI or 15454-SA-HD shelf assembly. Table 2-5 lists the cross-connect card compatibility for each optical card. For optical card software compatibility, see Table 4-2 on page 4-5. Note The XC card is compatible with most optical cards, with the exception of those cards noted as incompatible with the XCVT card, but does not support features new to Release 5.0 and later. Table 2-5 Optical Card Cross-Connect Compatibility Optical Card XCVT Card XC10G Card1 XC-VXC-10GCard1 OC3 IR 4 1310 Yes Yes Yes OC3 IR 4/STM1 SH 1310 Yes Yes Yes Cisco ONS 15454 Reference Manual, R8.5.x 2-4 78-18106-01 Chapter 2 Common Control Cards 2.1.3 Cross-Connect Card Compatibility Table 2-5 Optical Card Cross-Connect Compatibility (continued) Optical Card XCVT Card XC10G Card1 XC-VXC-10GCard1 OC3 IR /STM1SH 1310-8 — Yes Yes OC12 IR 1310 Yes Yes Yes OC12 LR 1310 Yes Yes Yes OC12 LR 1550 Yes Yes Yes OC12 IR/STM4 SH 1310 Yes Yes Yes OC12 LR/STM4 LH 1310 Yes Yes Yes OC12 LR/STM4 LH 1550 Yes Yes Yes OC12 IR/STM4 SH 1310-4 — Yes Yes OC48 LR 1550 Yes Yes Yes OC48 IR/STM16 SH AS 1310 Yes 2 Yes Yes OC48 LR/STM16 LH AS 1550 Yes2 Yes Yes OC48 ELR/STM16 EH 100 GHz Yes Yes Yes OC48 ELR 200 GHz Yes Yes Yes OC192 SR/STM64 IO 1310 — Yes Yes OC192 IR/STM64 SH 1550 — Yes Yes OC192 LR/STM64 LH 1550 — Yes Yes OC192 LR/STM64 LH ITU 15xx.xx — Yes Yes OC192SR1/STM64 IO Short Reach — and OC192/STM64 Any Reach (OC192-XFP cards) Yes Yes 15454_MRC-12 Yes Yes Yes MRC-2.5G-4 Yes Yes Yes 1. Requires a 15454-SA-ANSI or 15454-SA-HD shelf assembly. 2. Requires Software Release 3.2 and later in Slots 5, 6, 12, 13. Table 2-6 lists the cross-connect card compatibility for each Ethernet card. For Ethernet card software compatibility, see Table 5-2 on page 5-3. Note The XC card is compatible with most Ethernet cards, with the exception of the G1000-4, but does not support features new to Release 5.0 and later. Table 2-6 Ethernet Card Cross-Connect Compatibility Ethernet Cards XCVT Card XC10G Card1 XC-VXC-10G Card1 E100T-12 Yes — — E1000-2 Yes — — E100T-G Yes Yes Yes E1000-2-G Yes Yes Yes Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-5 Chapter 2 Common Control Cards 2.2 TCC2 Card Table 2-6 Ethernet Card Cross-Connect Compatibility (continued) Ethernet Cards XCVT Card XC10G Card1 XC-VXC-10G Card1 G1K-4 Yes, in Slots 5, 6, 12, 13 Yes Yes ML100T-12 Yes, in Slots 5, 6, 12, 13 Yes Yes ML1000-2 Yes, in Slots 5, 6, 12, 13 Yes Yes ML-MR-10 No Yes Yes ML100X-8 Yes, in Slots 5, 6, 12, 13 Yes Yes CE-100T-8 Yes Yes Yes CE-1000-4 Yes Yes Yes CE-MR-10 Yes Yes Yes 1. Requires a 15454-SA-ANSI or 15454-SA-HD shelf assembly. Table 2-7 lists the cross-connect card compatibility for each storage area network (SAN) card. For SAN card software compatibility, see the “6.1.3 FC_MR-4 Compatibility” section on page 6-4. Table 2-7 SAN Card Cross-Connect Compatibility SAN Cards XCVT Card XC10G Card1 XC-VXC-10G Card1 FC_MR-4 Yes Yes Yes 1. Requires SA-ANSI or SA-HD shelf assembly 2.2 TCC2 Card Note For hardware specifications, see the “A.4.1 TCC2 Card Specifications” section on page A-12. The TCC2 card performs system initialization, provisioning, alarm reporting, maintenance, diagnostics, IP address detection/resolution, SONET section overhead (SOH) DCC/GCC termination, and system fault detection for the ONS 15454. The TCC2 also ensures that the system maintains Stratum 3 (Telcordia GR-253-CORE) timing requirements. It monitors the supply voltage of the system. Note The TCC2 card requires Software Release 4.0.0 or later. Note The LAN interface of the TCC2 card meets the standard Ethernet specifications by supporting a cable length of 328 ft (100 m) at temperatures from 32 to 149 degrees Fahrenheit (0 to 65 degrees Celsius). The interfaces can operate with a cable length of 32.8 ft (10 m) maximum at temperatures from –40 to 32 degrees Fahrenheit (–40 to 0 degrees Celsius). Figure 2-1 shows the faceplate and block diagram for the TCC2 card. Cisco ONS 15454 Reference Manual, R8.5.x 2-6 78-18106-01 Chapter 2 Common Control Cards 2.2.1 TCC2 Card Functionality Figure 2-1 TCC2 Card Faceplate and Block Diagram BACKPLANE Ref Clocks (all I/O Slots) TCC2 -48V PWR Monitors System Timing BITS Input/ Output FPGA Real Time Clock FAIL PWR A B TCCA ASIC SCL Processor DCC Processor SCL Links to All Cards ACT/STBY MCC1 HDLC Message Bus MCC2 CRIT MAJ MIN Serial Debug SCC1 SCC2 REM SYNC ACO Modem Interface SCC3 ACO 400MHz Processor Mate TCC2 HDLC Link FCC1 LAMP SDRAM Memory & Compact Flash Modem Interface (Not Used) Communications Processor SCC4 Mate TCC2 Ethernet Port FCC2 RS-232 TCP/IP Faceplate Ethernet Port Ethernet Repeater Backplane Ethernet Port (Shared with Mate TCC2) RS-232 Craft Interface Note: Only 1 RS-232 Port Can Be Active Backplane Port Will Supercede Faceplate Port 137639 Faceplate RS-232 Port Backplane RS-232 Port (Shared with Mate TCC2) 2.2.1 TCC2 Card Functionality The TCC2 card supports multichannel, high-level data link control (HDLC) processing for the DCC. Up to 84 DCCs can be routed over the TCC2 card and up to 84 section DCCs can be terminated at the TCC2 card (subject to the available optical digital communication channels). The TCC2 card selects and processes 84 DCCs to facilitate remote system management interfaces. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-7 Chapter 2 Common Control Cards 2.2.2 TCC2 Card-Level Indicators The TCC2 card also originates and terminates a cell bus carried over the module. The cell bus supports links between any two cards in the node, which is essential for peer-to-peer communication. Peer-to-peer communication accelerates protection switching for redundant cards. The node database, IP address, and system software are stored in TCC2 card nonvolatile memory, which allows quick recovery in the event of a power or card failure. The TCC2 card performs all system-timing functions for each ONS 15454. The TCC2 monitors the recovered clocks from each traffic card and two BITS ports (DS1, 1.544 MHz) for frequency accuracy. The TCC2 selects a recovered clock, a BITS, or an internal Stratum 3 reference as the system-timing reference. You can provision any of the clock inputs as primary or secondary timing sources. A slow-reference tracking loop allows the TCC2 to synchronize with the recovered clock, which provides holdover if the reference is lost. The TCC2 monitors both supply voltage inputs on the shelf. An alarm is generated if one of the supply voltage inputs has a voltage out of the specified range. Install TCC2 cards in Slots 7 and 11 for redundancy. If the active TCC2 fails, traffic switches to the protect TCC2. All TCC2 protection switches conform to protection switching standards when the bit error rate (BER) counts are not in excess of 1 * 10 exp – 3 and completion time is less than 50 ms. The TCC2 card has two built-in interface ports for accessing the system: an RJ-45 10BaseT LAN interface and an EIA/TIA-232 ASCII interface for local craft access. It also has a 10BaseT LAN port for user interfaces over the backplane. Note When using the LAN RJ-45 craft interface or back panel wirewrap LAN connection, the connection must be 10BASE T, half duplex. Full duplex and autonegotiate settings should not be used because they might result in a loss of visibility to the node. Note Cisco does not support operation of the ONS 15454 with only one TCC2 card. For full functionality and to safeguard your system, always operate with two TCC2 cards. Note When a second TCC2 card is inserted into a node, it synchronizes its software, its backup software, and its database with the active TCC2. If the software version of the new TCC2 does not match the version on the active TCC2, the newly inserted TCC2 copies from the active TCC2, taking about 15 to 20 minutes to complete. If the backup software version on the new TCC2 does not match the version on the active TCC2, the newly inserted TCC2 copies the backup software from the active TCC2 again, taking about 15 to 20 minutes. Copying the database from the active TCC2 takes about 3 minutes. Depending on the software version and backup version the new TCC2 started with, the entire process can take between 3 and 40 minutes. 2.2.2 TCC2 Card-Level Indicators The TCC2 faceplate has ten LEDs. Table 2-8 describes the two card-level LEDs on the TCC2 card faceplate. Cisco ONS 15454 Reference Manual, R8.5.x 2-8 78-18106-01 Chapter 2 Common Control Cards 2.2.3 Network-Level Indicators Table 2-8 TCC2 Card-Level Indicators Card-Level LEDs Definition Red FAIL LED This LED is on during reset. The FAIL LED flashes during the boot and write process. Replace the card if the FAIL LED persists. ACT/STBY LED Indicates the TCC2 is active (green) or in standby (amber) mode. The ACT/STBY LED also provides the timing reference and shelf control. When the active TCC2 is writing to its database or to the standby TCC2 database, the card LEDs blink. To avoid memory corruption, do not remove the TCC2 when the active or standby LED is blinking. Green (Active) Amber (Standby) 2.2.3 Network-Level Indicators Table 2-8 describes the six network-level LEDs on the TCC2 faceplate. TCC2 Network-Level Indicators System-Level LEDs Definition Red CRIT LED Indicates critical alarms in the network at the local terminal. Red MAJ LED Indicates major alarms in the network at the local terminal. Amber MIN LED Indicates minor alarms in the network at the local terminal. Red REM LED Provides first-level alarm isolation. The remote (REM) LED turns red when an alarm is present in one or more of the remote terminals. Green SYNC LED Indicates that node timing is synchronized to an external reference. Green ACO LED After pressing the alarm cutoff (ACO) button, the ACO LED turns green. The ACO button opens the audible alarm closure on the backplane. ACO is stopped if a new alarm occurs. After the originating alarm is cleared, the ACO LED and audible alarm control are reset. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-9 Chapter 2 Common Control Cards 2.2.4 Power-Level Indicators 2.2.4 Power-Level Indicators Table 2-9 describes the two power-level LEDs on the TCC2 faceplate. Table 2-9 TCC2 Power-Level Indicators Power-Level LEDs Definition Green/Amber/Red PWR A LED The PWR A LED is green when the voltage on supply input A is between the low battery voltage (LWBATVG) and high battery voltage (HIBATVG) thresholds. The LED is amber when the voltage on supply input A is between the high battery voltage and extremely high battery voltage (EHIBATVG) thresholds or between the low battery voltage and extremely low battery voltage (ELWBATVG) thresholds. The LED is red when the voltage on supply input A is above extremely high battery voltage or below extremely low battery voltage thresholds. Green/Amber/Red PWR B LED The PWR B LED is green when the voltage on supply input B is between the low battery voltage and high battery voltage thresholds. The LED is amber when the voltage on supply input B is between the high battery voltage and extremely high battery voltage thresholds or between the low battery voltage and extremely low battery voltage thresholds. The LED is red when the voltage on supply input B is above extremely high battery voltage or below extremely low battery voltage thresholds. 2.3 TCC2P Card Note For hardware specifications, see the “A.4.2 TCC2P Card Specifications” section on page A-13. The TCC2P card is an enhanced version of the TCC2 card. For Software Release 5.0 and later, the primary enhancements are Ethernet security features and 64K composite clock BITS timing. It also supports E1 SDH external timing sources so that a SONET shelf can be deployed in a network using SDH timing. SDH timing is typically used when the SONET platform is deployed for Au3 SDH applications. The TCC2P card performs system initialization, provisioning, alarm reporting, maintenance, diagnostics, IP address detection/resolution, SONET SOH DCC/GCC termination, and system fault detection for the ONS 15454. The TCC2P card also ensures that the system maintains Stratum 3 (Telcordia GR-253-CORE) timing requirements. It monitors the supply voltage of the system. Note The LAN interface of the TCC2P card meets the standard Ethernet specifications by supporting a cable length of 328 ft (100 m) at temperatures from 32 to 149 degrees Fahrenheit (0 to 65 degrees Celsius). The interfaces can operate with a cable length of 32.8 ft (10 m) maximum at temperatures from –40 to 32 degrees Fahrenheit (–40 to 0 degrees Celsius). Figure 2-2 shows the faceplate and block diagram for the TCC2P card. Cisco ONS 15454 Reference Manual, R8.5.x 2-10 78-18106-01 Chapter 2 Common Control Cards 2.3.1 TCC2P Functionality Figure 2-2 TCC2P Faceplate and Block Diagram BACKPLANE TCC2P -48V PWR Monitors Ref Clocks (all I/O Slots) System Timing BITS Input/ Output FPGA Real Time Clock FAIL PWR A B DCC Processor TCCA ASIC SCL Processor SCL Links to All Cards ACT/STBY MCC1 CRIT Serial Debug MAJ MIN SMC1 HDLC Message Bus MCC2 SCC2 REM SYNC Modem Interface SCC3 ACO 400MHz Processor ACO Mate TCC2 HDLC Link FCC1 LAMP Communications Processor SDRAM Memory & Compact Flash Ethernet Phy SCC1 SCC4 Modem Interface (Not Used) FCC2 RS-232 Faceplate Ethernet Port Ethernet Switch Backplane Ethernet Port (Shared with Mate TCC2) Mate TCC2 Ethernet Port RS-232 Craft Interface Faceplate RS-232 Port Note: Only 1 RS-232 Port Can Be Active Backplane Port Will Supercede Faceplate Port Backplane RS-232 Port (Shared with Mate TCC2) 137640 TCP/IP 2.3.1 TCC2P Functionality The TCC2P card supports multichannel, high-level data link control (HDLC) processing for the DCC. Up to 84 DCCs can be routed over the TCC2P card and up to 84 section DCCs can be terminated at the TCC2P card (subject to the available optical digital communication channels). The TCC2P selects and processes 84 DCCs to facilitate remote system management interfaces. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-11 Chapter 2 Common Control Cards 2.3.1 TCC2P Functionality The TCC2P card also originates and terminates a cell bus carried over the module. The cell bus supports links between any two cards in the node, which is essential for peer-to-peer communication. Peer-to-peer communication accelerates protection switching for redundant cards. The node database, IP address, and system software are stored in TCC2P card nonvolatile memory, which allows quick recovery in the event of a power or card failure. The TCC2P card monitors both supply voltage inputs on the shelf. An alarm is generated if one of the supply voltage inputs has a voltage out of the specified range. Install TCC2P cards in Slots 7 and 11 for redundancy. If the active TCC2P card fails, traffic switches to the protect TCC2P card. All TCC2P card protection switches conform to protection switching standards when the BER counts are not in excess of 1 * 10 exp – 3 and completion time is less than 50 ms. The TCC2P card has two built-in Ethernet interface ports for accessing the system: one built-in RJ-45 port on the front faceplate for on-site craft access and a second port on the backplane. The rear Ethernet interface is for permanent LAN access and all remote access via TCP/IP as well as for Operations Support System (OSS) access. The front and rear Ethernet interfaces can be provisioned with different IP addresses using CTC. Two EIA/TIA-232 serial ports, one on the faceplate and a second on the backplane, allow for craft interface in TL1 mode. Note To use the serial port craft interface wire-wrap pins on the backplane, the DTR signal line on the backplane port wire-wrap pin must be connected and active. Note When using the LAN RJ-45 craft interface or back panel wirewrap LAN connection, the connection must be 10BASE T, half duplex. Full duplex and autonegotiate settings should not be used because they might result in a loss of visibility to the node. Note Cisco does not support operation of the ONS 15454 with only one TCC2P card. For full functionality and to safeguard your system, always operate with two TCC2P cards. Note When a second TCC2P card is inserted into a node, it synchronizes its software, its backup software, and its database with the active TCC2P card. If the software version of the new TCC2P card does not match the version on the active TCC2P card, the newly inserted TCC2P card copies from the active TCC2P card, taking about 15 to 20 minutes to complete. If the backup software version on the new TCC2P card does not match the version on the active TCC2P card, the newly inserted TCC2P card copies the backup software from the active TCC2P card again, taking about 15 to 20 minutes. Copying the database from the active TCC2P card takes about 3 minutes. Depending on the software version and backup version the new TCC2P card started with, the entire process can take between 3 and 40 minutes. 2.3.1.1 System Timing Functions The TCC2P card performs all system-timing functions for each ONS 15454. The TCC2P card monitors the recovered clocks from each traffic card and two BITS ports (BITS_IN_A and BITS_IN-B) for frequency accuracy. The TCC2P card selects a recovered clock, a BITS clock, or an internal Stratum 3 Cisco ONS 15454 Reference Manual, R8.5.x 2-12 78-18106-01 Chapter 2 Common Control Cards 2.3.1 TCC2P Functionality reference as the system-timing reference. You can provision any of the clock inputs as primary or secondary timing sources. A slow-reference tracking loop allows the TCC2P card to synchronize with the recovered clock, which provides holdover if the reference is lost. The minimum free-run accuracy, holdover stability, pull-in, and hold-in characteristics are as defined in ITU-T G.813 option I in Section 5, 6, and 10, ITU-T G.811 Section 5, and ITU-T G.812 Sections 6 and 7, as well as in ANSI EN 300 462-5-1. Note If SDH timing is selected (see the “2.3.1.1.2 SDH Timing Operation” section on page 2-13), it is not possible to select an E1 or DS1 port from the DS1/E1-56 high-density card as a timing reference. 2.3.1.1.1 SONET Timing Operation The TCC2P card supports a 64 kHz + 8 kHz composite clock BITS input (BITS IN) as well as a 6.312-MHz BITS OUT clock. The BITS clock on the system is configurable as DS1 (default), 1.544 MHz, or 64 kHz. The BITS OUT clock runs at a rate determined by the BITS IN clock, as follows: • If BITS IN = DS1, then BITS OUT = DS1 (default) • If BITS IN = 1.544 MHz (square wave clock), then BITS OUT = 1.544 MHz (square wave clock) • If BITS IN = 64 kHz, then BITS OUT = 6.312 MHz or DS1 A BITS output interface configured as 6.312 MHz complies with ITU-T G.703, Appendix II, Table II.4, with a monitor level of –40 dBm +/– 4 dBm. 2.3.1.1.2 SDH Timing Operation The TCC2P card supports typical external E1 SDH timing sources so that the card can be provisioned to accept either an SDH or SONET timing standard. The initial default is for the card to use SONET timing; the default can be changed to SDH timing after the TCC2P card boots up. The BITS OUT clock runs at a rate determined by the BITS IN clock, as follows: • If BITS IN = E1, then BITS OUT = E1 • If BITS IN = 2.048 MHz (square wave clock), then BITS OUT = 2.048 MHz (square wave clock) • If BITS IN = 64 kHz, then BITS OUT = 6.312 MHz The TCC2P card supports the E1 BITS OUT signal as defined in ITU-T G.703 Section 9, and the BITS OUT 2.048 MHz signal as defined in ITU-T G.703 Section 13. All of the BITS OUT signals meet the output signal criteria (including jitter and wander) as defined in ITU-T G.813 Sections 5 and 6, ITU-T G.811 Section 5, and ITU-T G.812, Section 6. When SDH timing is selected, SDH Sync Status Messaging (SSM) is transmitted on the output ports and received on the input ports. SSM can be enabled or disabled. The following framing options are allowed when E1 2.048 MHz timing is selected: • Frame Alignment Signal (FAS) • Frame Alignment Signal plus Channel Associated Signal (FAS + CAS) • Frame Alignment Signal plus Cyclic Redundancy Check (FAS + CRC) • Frame Alignment Signal plus Channel Associated Signal plus Cyclic Redundancy Check (FAS + CAS + CRC) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-13 Chapter 2 Common Control Cards 2.3.2 TCC2P Card-Level Indicators 2.3.2 TCC2P Card-Level Indicators The TCC2P faceplate has ten LEDs. Table 2-10 describes the two card-level LEDs on the TCC2P faceplate. Table 2-10 TCC2P Card-Level Indicators Card-Level LEDs Definition Red FAIL LED This LED is on during reset. The FAIL LED flashes during the boot and write process. Replace the card if the FAIL LED persists. ACT/STBY LED Indicates the TCC2P is active (green) or in standby (amber) mode. The ACT/STBY LED also provides the timing reference and shelf control. When the active TCC2P is writing to its database or to the standby TCC2P database, the card LEDs blink. To avoid memory corruption, do not remove the TCC2P when the active or standby LED is blinking. Green (Active) Amber (Standby) 2.3.3 Network-Level Indicators Table 2-11 describes the six network-level LEDs on the TCC2P faceplate. Table 2-11 TCC2P Network-Level Indicators System-Level LEDs Definition Red CRIT LED Indicates critical alarms in the network at the local terminal. Red MAJ LED Indicates major alarms in the network at the local terminal. Amber MIN LED Indicates minor alarms in the network at the local terminal. Red REM LED Provides first-level alarm isolation. The REM LED turns red when an alarm is present in one or more of the remote terminals. Green SYNC LED Indicates that node timing is synchronized to an external reference. Green ACO LED After pressing the ACO button, the ACO LED turns green. The ACO button opens the audible alarm closure on the backplane. ACO is stopped if a new alarm occurs. After the originating alarm is cleared, the ACO LED and audible alarm control are reset. Cisco ONS 15454 Reference Manual, R8.5.x 2-14 78-18106-01 Chapter 2 Common Control Cards 2.3.4 Power-Level Indicators 2.3.4 Power-Level Indicators Table 2-12 describes the two power-level LEDs on the TCC2P faceplate. Table 2-12 TCC2P Power-Level Indicators Power-Level LEDs Definition Green/Amber/Red PWR A LED The PWR A LED is green when the voltage on supply input A is between the low battery voltage (LWBATVG) and high battery voltage (HIBATVG) thresholds. The LED is amber when the voltage on supply input A is between the high battery voltage and extremely high battery voltage (EHIBATVG) thresholds or between the low battery voltage and extremely low battery voltage (ELWBATVG) thresholds. The LED is red when the voltage on supply input A is above extremely high battery voltage or below extremely low battery voltage thresholds. Green/Amber/Red PWR B LED The PWR B LED is green when the voltage on supply input B is between the low battery voltage and high battery voltage thresholds. The LED is amber when the voltage on supply input B is between the high battery voltage and extremely high battery voltage thresholds or between the low battery voltage and extremely low battery voltage thresholds. The LED is red when the voltage on supply input B is above extremely high battery voltage or below extremely low battery voltage thresholds. 2.4 XCVT Card Note For hardware specifications, see the “A.4.3 XCVT Card Specifications” section on page A-14. The Cross Connect Virtual Tributary (XCVT) card establishes connections at the STS-1 and VT levels. The XCVT provides STS-48 capacity to Slots 5, 6, 12, and 13, and STS-12 capacity to Slots 1 to 4 and 14 to 17. Any STS-1 on any port can be connected to any other port, meaning that the STS cross-connections are nonblocking. Figure 2-3 shows the XCVT faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-15 Chapter 2 Common Control Cards 2.4.1 XCVT Functionality Figure 2-3 XCVT Faceplate and Block Diagram XCVT FAIL ACT/STBY Input ports Output ports 0 0 Ports 0 1 2 STS ASIC1 3 4 0 Ports 1 1 2 2 3 3 4 4 5 5 5 6 1 STS ASIC2 2 3 4 5 6 6 7 7 8 8 9 VT ASIC 9 10 11 11 61341 10 33678 12931 2.4.1 XCVT Functionality The STS-1 switch matrix on the XCVT card consists of 288 bidirectional ports and adds a VT matrix that can manage up to 336 bidirectional VT1.5 ports or the equivalent of a bidirectional STS-12. The VT1.5-level signals can be cross connected, dropped, or rearranged. The TCC2/TCC2P card assigns bandwidth to each slot on a per STS-1 or per VT1.5 basis. The switch matrices are fully crosspoint and broadcast supporting. The XCVT card provides: • 288 STS bidirectional ports • 144 STS bidirectional cross-connects • 672 VT1.5 ports via 24 logical STS ports • 336 VT1.5 bidirectional cross-connects • Nonblocking at the STS level • STS-1/3c/6c/12c/48c cross-connects Cisco ONS 15454 Reference Manual, R8.5.x 2-16 78-18106-01 Chapter 2 Common Control Cards 2.4.2 VT Mapping The XCVT card works with the TCC2/TCC2P cards to maintain connections and set up cross-connects within the node. The cross-connect cards (such as the XCVT and XC10G), installed in Slots 8 and 10, are required to operate the ONS 15454. You can establish cross-connect (circuit) information through CTC. The TCC2/TCC2P cards establish the proper internal cross-connect information and relay the setup information to the XCVT card. Caution Do not operate the ONS 15454 with only one cross-connect card. Two cross-connect cards of the same type (two XCVT or two XC10G cards) must always be installed. Figure 2-4 shows the cross-connect matrix. Figure 2-4 XCVT Cross-Connect Matrix XCVT STS-1 Cross-connect ASIC (288x288 STS-1) Input Ports 8X STS-12 4X STS-12/48 Output Ports 1 1 2 2 3 3 4 4 5 5 8X STS-12 4X STS-12/48 6 VT 1.5 Cross-connect ASIC 336 bidirectional VT 1.5 cross-connects 32125 VTXC 2.4.2 VT Mapping The VT structure is designed to transport and switch payloads below the DS-3 rate. The ONS 15454 performs VT mapping according to Telcordia GR-253-CORE standards. Table 2-13 shows the VT numbering scheme for the ONS 15454 as it relates to the Telcordia standard. Table 2-13 VT Mapping ONS 15454 VT Number Telcordia Group/VT Number VT1 Group1/VT1 VT2 Group2/VT1 VT3 Group3/VT1 VT4 Group4/VT1 VT5 Group5/VT1 VT6 Group6/VT1 VT7 Group7/VT1 VT8 Group1/VT2 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-17 Chapter 2 Common Control Cards 2.4.3 XCVT Hosting DS3XM-6 or DS3XM-12 Table 2-13 VT Mapping (continued) ONS 15454 VT Number Telcordia Group/VT Number VT9 Group2/VT2 VT10 Group3/VT2 VT11 Group4/VT2 VT12 Group5/VT2 VT13 Group6/VT2 VT14 Group7/VT2 VT15 Group1/VT3 VT16 Group2/VT3 VT17 Group3/VT3 VT18 Group4/VT3 VT19 Group5/VT3 VT20 Group6/VT3 VT21 Group7/VT3 VT22 Group1/VT4 VT23 Group2/VT4 VT24 Group3/VT4 VT25 Group4/VT4 VT26 Group5/VT4 VT27 Group6/VT4 VT28 Group7/VT4 2.4.3 XCVT Hosting DS3XM-6 or DS3XM-12 A DS3XM card can demultiplex (map down to a lower rate) M13-mapped DS-3 signals into 28 DS-1s that are then mapped to VT1.5 payloads. The VT1.5s can then be cross-connected by the XCVT card. The XCVT card can host a maximum of 336 bidirectional VT1.5s. 2.4.4 XCVT Card-Level Indicators Table 2-14 shows the two card-level LEDs on the XCVT card faceplate. Cisco ONS 15454 Reference Manual, R8.5.x 2-18 78-18106-01 Chapter 2 Common Control Cards 2.5 XC10G Card Table 2-14 XCVT Card-Level Indicators Card-Level Indicators Definition Red FAIL LED Indicates that the cards processor is not ready. Replace the card if the red FAIL LED persists. ACT/STBY LED Indicates whether the XCVT card is active and carrying traffic (green) or in standby mode to the active XCVT card (amber). Green (Active) Amber (Standby) 2.5 XC10G Card Note For hardware specifications, see the “A.4.4 XC10G Card Specifications” section on page A-14. The 10 Gigabit Cross Connect (XC10G) card establishes connections at the STS-1 and VT levels. The XC10G provides STS-192 capacity to Slots 5, 6, 12, and 13, and STS-48 capacity to Slots 1 to 4 and 14 to 17. The XC10G allows up to four times the bandwidth of the XCVT cards. The XC10G provides a maximum of 576 STS-1 cross-connections through 1152 STS-1 ports. Any STS-1 on any port can be connected to any other port, meaning that the STS cross-connections are nonblocking. Figure 2-5 shows the XC10G faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-19 Chapter 2 Common Control Cards 2.5.1 XC10G Functionality Figure 2-5 XC10G Faceplate and Block Diagram XC10G Line 1 FAIL Line 2 ACT/STBY Line 3 Line 4 uP Interface Span 1 Span 2 Cross-Connect Matrix Span 3 Span 4 Line 5 VT Cross-Connect Matrix Line 6 Line 7 Line 8 Ref Clk A FLASH Ref Clk B B a c k p l a n e RAM uP Interface TCCA ASIC SCL Link Protect SCL 61342 Main SCL uP 2.5.1 XC10G Functionality The XC10G card manages up to 672 bidirectional VT1.5 ports and 1152 bidirectional STS-1 ports. The TCC2/TCC2P cards assign bandwidth to each slot on a per STS-1 or per VT1.5 basis. Two cross-connect cards, installed in Slots 8 and 10, are required to operate the ONS 15454. You can establish cross-connect (circuit) information through the CTC. The cross-connect card establishes the proper internal cross-connect information and sends the setup information to the cross-connect card. The XC10G card provides: • 1152 STS bidirectional ports • 576 STS bidirectional cross-connects • 672 VT1.5 ports via 24 logical STS ports • 336 VT1.5 bidirectional cross-connects • Nonblocking at STS level • STS-1/3c/6c/12c/48c/192c cross-connects Cisco ONS 15454 Reference Manual, R8.5.x 2-20 78-18106-01 Chapter 2 Common Control Cards 2.5.2 VT Mapping Caution Do not operate the ONS 15454 with only one XCVT or XC10G card. Two cross-connect cards of the same type (either two XCVT or two XC10G cards) must always be installed. Figure 2-6 shows the cross-connect matrix. Figure 2-6 XC10G Cross-Connect Matrix XC10G STS-1 Cross-connect ASIC (1152x1152 STS-1) Input Ports 8X STS-48 4X STS-192 Output Ports 1 1 2 2 . . . . . . . . 25 25 8X STS-48 4X STS-192 VT 1.5 Cross-connect ASIC VTXC 55386 336 bidirectional VT 1.5 cross-connects VT cross-connection occurs on the 25th port. 2.5.2 VT Mapping The VT structure is designed to transport and switch payloads below the DS-3 rate. The ONS 15454 performs VT mapping according to Telcordia GR-253-CORE standards. Table 2-15 shows the VT numbering scheme for the ONS 15454 as it relates to the Telcordia standard. Table 2-15 VT Mapping ONS 15454 VT Number Telcordia Group/VT Number VT1 Group1/VT1 VT2 Group2/VT1 VT3 Group3/VT1 VT4 Group4/VT1 VT5 Group5/VT1 VT6 Group6/VT1 VT7 Group7/VT1 VT8 Group1/VT2 VT9 Group2/VT2 VT10 Group3/VT2 VT11 Group4/VT2 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-21 Chapter 2 Common Control Cards 2.5.3 XC10G Hosting DS3XM-6 or DS3XM-12 Table 2-15 VT Mapping (continued) ONS 15454 VT Number Telcordia Group/VT Number VT12 Group5/VT2 VT13 Group6/VT2 VT14 Group7/VT2 VT15 Group1/VT3 VT16 Group2/VT3 VT17 Group3/VT3 VT18 Group4/VT3 VT19 Group5/VT3 VT20 Group6/VT3 VT21 Group7/VT3 VT22 Group1/VT4 VT23 Group2/VT4 VT24 Group3/VT4 VT25 Group4/VT4 VT26 Group5/VT4 VT27 Group6/VT4 VT28 Group7/VT4 2.5.3 XC10G Hosting DS3XM-6 or DS3XM-12 A DS3XM card can demultiplex (map down to a lower rate) M13-mapped DS-3 signals into 28 DS-1s that are then mapped to VT1.5 payloads. The VT1.5s can then be cross-connected by the XC10G card. The XC10G card can host a maximum of 336 bidirectional VT1.5s. 2.5.4 XC10G Card-Level Indicators Table 2-16 describes the two card-level LEDs on the XC10G faceplate. Table 2-16 XC10G Card-Level Indicators Card-Level Indicators Definition Red FAIL LED Indicates that the cards processor is not ready. This LED illuminates during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. ACT/STBY LED Indicates whether the XC10G is active and carrying traffic (green), or in standby mode to the active XC10G card (amber). Green (Active) Amber (Standby) Cisco ONS 15454 Reference Manual, R8.5.x 2-22 78-18106-01 Chapter 2 Common Control Cards 2.5.5 XCVT/XC10G/XC-VXC-10G Compatibility 2.5.5 XCVT/XC10G/XC-VXC-10G Compatibility The XC10G and XC-VXC-10G cards support the same features as the XCVT card. The XC10G or XC-VXC-10G cards are required for OC-192, OC-48 any-slot (AS), OC3-8, and OC12-4 operation. Do not use the XCVT card if you are using an OC-192, OC3-8, or OC12-4 card or if you install an OC-48 AS card in Slots 1 to 4 or 14 to 17. Note A configuration mismatch alarm occurs when an XCVT cross-connect card co-exists with an OC-192, OC3-8, or OC12-4 card placed in Slots 5, 6, 12, or 13 or with an OC-48 card placed in Slots 1 to 4 or 14 to 17. If you are using Ethernet cards, the E1000-2-G or the E100T-G must be used when the XC10G or XC-VXC-10G cross-connect card is in use. Do not pair an XCVT card with an XC10G or XC-VXC-10G card. When upgrading from an XCVT to the XC10G or XC-VXC-10G card, refer to the “Upgrade Cards and Spans” chapter in the Cisco ONS 15454 Procedure Guide for more information. 2.6 XC-VXC-10G Card Note For hardware specifications, see the “A.4.5 XC-VXC-10G Card Specifications” section on page A-15. The XC-VXC-10G card establishes connections at the STS and VT levels. The XC-VXC-10G provides STS-192 capacity to Slots 5, 6, 12, and 13, and STS-48 capacity to Slots 1 to 4 and 14 to 17. Any STS-1 on any port can be connected to any other port, meaning that the STS cross-connections are nonblocking. Figure 2-7 shows the XC-VXC-10G faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-23 Chapter 2 Common Control Cards 2.6.1 XC-VXC-10G Functionality Figure 2-7 XC-VXC-10G Faceplate and Block Diagram XC-VXC10G XC-VXC-10G Backplane Connectors SCL Bus FAIL IBPIA (2) ACT/STBY IBPIA (2) TCCA Clock FPGA STS-1 Cross Connect ASIC 2 VT Ports 2 VT Ports 6 AUX Ports FLASH 6 AUX Ports EDVT TULA GDX2 TU Cross Connect ASIC EEPROM Serial Port 2 VT Ports 2 VT Ports CPU VT Cross Connect ASIC DDR SDRAM DETLEF DDR FPGA 134364 CPLD TARAN GDX1 2.6.1 XC-VXC-10G Functionality The XC-VXC-10G card manages up to 1152 bidirectional high-order STS-1 ports. In addition, it is able to simultaneously manage one of the following low-order VT cross-connect arrangements: • 2688 bidirectional VT1.5 low-order ports, or • 2016 VT2 low-order ports, or • 1344 bidirectional VT1.5 ports and 1008 bidirectional VT2 ports (mixed grooming) The TCC2/TCC2P card assigns bandwidth to each slot on a per STS-1, per VT1.5, or per VT2 basis. The switch matrices are fully crosspoint and broadcast supporting. Cisco ONS 15454 Reference Manual, R8.5.x 2-24 78-18106-01 Chapter 2 Common Control Cards 2.6.1 XC-VXC-10G Functionality At the STS level (high-order cross-connect), the XC-VXC-10G is always non-blocking (any STS-1 from the system can be cross-connected to any other STS-1 without limitation up to 1152 bidirectional STS-1 ports (576 STS-1 cross-connects). In addition, for “mixed” VT1.5 and VT2 grooming, 50% of the available VT resources (ports) are allocated to each VT circuit type. The following three modes are supported (only one mode is available at a time): • Mode 1: full VT1.5 cross-connect, which is 2688 bidirectional VT1.5 ports (1344 bidirectional VT1.5 cross-connects) • Mode 2: full VT2 cross-connect, which is 2016 bidirectional VT2 ports (1008 bidirectional VT2 cross-connects) • Mode 3 (mixed grooming): 50% VT1.5 and 50% VT2 XC, which is 1344 bidirectional VT1.5 ports and 1008 bidirectional VT2 ports (672 bidirectional VT1.5 and 504 VT2 bidirectional cross-connects) The XC-VXC-10G card provides: Note • 1152 STS bidirectional ports • 576 STS bidirectional cross-connects • 2688 VT1.5 ports via 96 logical STS ports • 1344 VT1.5 bidirectional cross-connects • 2016 VT2 ports via 96 logical STS ports • 1008 VT2 bidirectional cross-connects • Mixed grooming (50% VT1.5 and 50% VT2) • Nonblocking at the STS level • VT1.5, VT2, and STS-1/3c/6c/12c/48c/192c cross-connects VT 2 circuit provisioning works between optical cards and the DS3/EC1-48 card (EC1 ports, not the ports provisioned for DS3) The XC-VXC-10G supports errorless side switches (switching from one XC-VXC-10G on one side of the shelf to the other XC-VXC-10G on the other side of the shelf) when the switch is initiated through software and the shelf is equipped with TCC2/TCC2P cards. The XCVT and XC10G cards do not support errorless switching. Cross-connect and provisioning information is established through the user interface on the TCC2/TCC2P card. In turn, the TCC2/TCC2P card establishes the proper internal cross-connect information and relays the setup information to the XC-VXC-10G card so that the proper cross-connection is established within the system. The XC-VXC-10G card is deployed in Slots 8 or 10. Upgrading a system to an XC-VXC-10G from an earlier cross-connect module type is performed in-service, with hitless operation (less than 50-ms impact to any traffic). The XC-VXC-10G can be used with either the standard ANSI shelf assembly (15454-SA-ANSI) or high-density shelf assembly (15454-SA-HD). Caution Do not operate the ONS 15454 with only one XC-VXC-10G cross-connect card. Two cross-connect cards must always be installed. Figure 2-8 shows the XC-VXC-10G cross-connect matrix. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-25 Chapter 2 Common Control Cards 2.6.2 VT Mapping Figure 2-8 XC-VXC-10G Cross-Connect Matrix XC-XVC-10G STS-1 Cross-connect ASIC (1152x1152 STS-1) Input Ports 8X STS-48 4X STS-192 Output Ports 1 1 2 2 . . . . . . . . 20 20 8X STS-48 4X STS-192 6X STS-48 2X STS-48 (VT Ports) TUXC TU-3 Cross-connect ASIC (bypassed in SONETmode) VTXC VT 1.5/VT 2 Cross-connect ASIC 1344 bidirectional VT 1.5 cross-connects, or 1008 bidirectional VT 2 cross-connects, or Mixed grooming (50% VT1.5 and 50% VT2) 134272 2X STS-48 (VT Ports) 2.6.2 VT Mapping The VT structure is designed to transport and switch payloads below the DS-3 rate. The ONS 15454 performs VT mapping according to Telcordia GR-253-CORE standards. Table 2-15 shows the VT numbering scheme for the ONS 15454 as it relates to the Telcordia standard. Table 2-17 VT Mapping ONS 15454 VT Number Telcordia Group/VT Number VT1 Group1/VT1 VT2 Group2/VT1 VT3 Group3/VT1 VT4 Group4/VT1 VT5 Group5/VT1 VT6 Group6/VT1 VT7 Group7/VT1 VT8 Group1/VT2 VT9 Group2/VT2 VT10 Group3/VT2 VT11 Group4/VT2 VT12 Group5/VT2 VT13 Group6/VT2 Cisco ONS 15454 Reference Manual, R8.5.x 2-26 78-18106-01 Chapter 2 Common Control Cards 2.6.3 XC-VXC-10G Hosting DS3XM-6 or DS3XM-12 Table 2-17 VT Mapping (continued) ONS 15454 VT Number Telcordia Group/VT Number VT14 Group7/VT2 VT15 Group1/VT3 VT16 Group2/VT3 VT17 Group3/VT3 VT18 Group4/VT3 VT19 Group5/VT3 VT20 Group6/VT3 VT21 Group7/VT3 VT22 Group1/VT4 VT23 Group2/VT4 VT24 Group3/VT4 VT25 Group4/VT4 VT26 Group5/VT4 VT27 Group6/VT4 VT28 Group7/VT4 2.6.3 XC-VXC-10G Hosting DS3XM-6 or DS3XM-12 A DS3XM card can demultiplex (map down to a lower rate) M13-mapped DS-3 signals into 28 DS-1s that are then mapped to VT1.5 payloads. The VT1.5s can then be cross-connected by the XC-VXC-10G card. The XC-VXC-10G card can host a maximum of 1344 bidirectional VT1.5s. 2.6.4 XC-VXC-10G Card-Level Indicators Table 2-18 describes the two card-level LEDs on the XC-VXC-10G faceplate. Table 2-18 XC-VXC-10G Card-Level Indicators Card-Level Indicators Definition Red FAIL LED Indicates that the cards processor is not ready. This LED illuminates during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. ACT/STBY LED Indicates whether the XC10G is active and carrying traffic (green), or in standby mode to the active XC10G card (amber). Green (Active) Amber (Standby) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-27 Chapter 2 Common Control Cards 2.6.5 XC-VXC-10G Compatibility 2.6.5 XC-VXC-10G Compatibility The XC-VXC-10G card supports the same features as the XC10G card. Either the XC10G or XC-VXC-10G card is required for OC-192, OC3-8, and OC12-4 operation and OC-48 AS operation. If you are using Ethernet cards, the E1000-2-G or the E100T-G must be used when the XC-VXC-10G cross-connect card is in use. When upgrading from an XC10G card to an XC-VXC-10G card, refer to the “Upgrade Cards and Spans” chapter in the Cisco ONS 15454 Procedure Guide for more information. Also refer to the “2.1.2 Card Compatibility” section on page 2-3. 2.7 AIC-I Card Note For hardware specifications, see the “A.4.6 AIC-I Card Specifications” section on page A-15. The optional Alarm Interface Controller–International (AIC-I) card provides customer-defined (environmental) alarms and controls and supports local and express orderwire. It provides 12 customer-defined input and 4 customer-defined input/output contacts. The physical connections are through the backplane wire-wrap pin terminals. If you use the additional AEP, the AIC-I card can support up to 32 inputs and 16 outputs, which are connected on the AEP connectors. A power monitoring function monitors the supply voltage (–48 VDC). Figure 2-9 shows the AIC-I faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 2-28 78-18106-01 Chapter 2 Common Control Cards 2.7.1 AIC-I Card-Level Indicators Figure 2-9 AIC-I Faceplate and Block Diagram AIC-1 FAIL Fail PWR A B AIC-I Act ACT UDC-A UDC-B ACC INPUT/OUTPUT DCC-A DCC-B Express orderwire ACC (DTMF) Ring Local orderwire 12/16 x IN (DTMF) UDC-A Ring 4x IN/OUT UDC-B Ringer DCC-A Power Monitoring DCC-B RING Input LOW LED x2 AIC-I FPGA Output EOW RING EEPROM 78828 SCL links 2.7.1 AIC-I Card-Level Indicators Table 2-19 describes the eight card-level LEDs on the AIC-I card faceplate. Table 2-19 AIC-I Card-Level Indicators Card-Level LEDs Description Red FAIL LED Indicates that the cards processor is not ready. The FAIL LED is on during Reset and flashes during the boot process. Replace the card if the red FAIL LED persists. Green ACT LED Indicates the AIC-I card is provisioned for operation. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-29 Chapter 2 Common Control Cards 2.7.2 External Alarms and Controls Table 2-19 AIC-I Card-Level Indicators (continued) Card-Level LEDs Description Green/Red PWR A LED The PWR A LED is green when a supply voltage within a specified range has been sensed on supply input A. It is red when the input voltage on supply input A is out of range. Green/Red PWR B LED The PWR B LED is green when a supply voltage within a specified range has been sensed on supply input B. It is red when the input voltage on supply input B is out of range. Amber INPUT LED The INPUT LED is amber when there is an alarm condition on at least one of the alarm inputs. Amber OUTPUT LED The OUTPUT LED is amber when there is an alarm condition on at least one of the alarm outputs. Green RING LED The RING LED on the local orderwire (LOW) side is flashing green when a call is received on the LOW. Green RING LED The RING LED on the express orderwire (EOW) side is flashing green when a call is received on the EOW. 2.7.2 External Alarms and Controls The AIC-I card provides input/output alarm contact closures. You can define up to twelve external alarm inputs and 4 external alarm inputs/outputs (user configurable). The physical connections are made using the backplane wire-wrap pins. See the “1.12 Alarm Expansion Panel” section on page 1-56 for information about increasing the number of input/output contacts. LEDs on the front panel of the AIC-I indicate the status of the alarm lines, one LED representing all of the inputs and one LED representing all of the outputs. External alarms (input contacts) are typically used for external sensors such as open doors, temperature sensors, flood sensors, and other environmental conditions. External controls (output contacts) are typically used to drive visual or audible devices such as bells and lights, but they can control other devices such as generators, heaters, and fans. You can program each of the twelve input alarm contacts separately. You can program each of the sixteen input alarm contacts separately. Choices include: • Alarm on Closure or Alarm on Open • Alarm severity of any level (Critical, Major, Minor, Not Alarmed, Not Reported) • Service Affecting or Non-Service Affecting alarm-service level • 63-character alarm description for CTC display in the alarm log. You cannot assign the fan-tray abbreviation for the alarm; the abbreviation reflects the generic name of the input contacts. The alarm condition remains raised until the external input stops driving the contact or you unprovision the alarm input. You cannot assign the fan-tray abbreviation for the alarm; the abbreviation reflects the generic name of the input contacts. The alarm condition remains raised until the external input stops driving the contact or you provision the alarm input. Cisco ONS 15454 Reference Manual, R8.5.x 2-30 78-18106-01 Chapter 2 Common Control Cards 2.7.3 Orderwire The output contacts can be provisioned to close on a trigger or to close manually. The trigger can be a local alarm severity threshold, a remote alarm severity, or a virtual wire: • Local NE alarm severity: A hierarchy of Not Reported, Not Alarmed, Minor, Major, or Critical alarm severities that you set to cause output closure. For example, if the trigger is set to Minor, a Minor alarm or above is the trigger. • Remote NE alarm severity: Same as the local network element (NE) alarm severity but applies to remote alarms only. • Virtual wire entities: You can provision any environmental alarm input to raise a signal on any virtual wire on external outputs 1 through 4 when the alarm input is an event. You can provision a signal on any virtual wire as a trigger for an external control output. You can also program the output alarm contacts (external controls) separately. In addition to provisionable triggers, you can manually force each external output contact to open or close. Manual operation takes precedence over any provisioned triggers that might be present. Note The number of inputs and outputs can be increased using the AEP. The AEP is connected to the shelf backplane and requires an external wire-wrap panel. 2.7.3 Orderwire Orderwire allows a craftsperson to plug a phoneset into an ONS 15454 and communicate with craftspeople working at other ONS 15454s or other facility equipment. The orderwire is a pulse code modulation (PCM) encoded voice channel that uses E1 or E2 bytes in section/line overhead. The AIC-I allows simultaneous use of both local (section overhead signal) and express (line overhead signal) orderwire channels on an SDH ring or particular optics facility. Express orderwire also allows communication via regeneration sites when the regenerator is not a Cisco device. You can provision orderwire functions with CTC similar to the current provisioning model for DCC/GCC channels. In CTC, you provision the orderwire communications network during ring turn-up so that all NEs on the ring can reach one another. Orderwire terminations (that is, the optics facilities that receive and process the orderwire channels) are provisionable. Both express and local orderwire can be configured as on or off on a particular SONET facility. The ONS 15454 supports up to four orderwire channel terminations per shelf. This allows linear, single ring, dual ring, and small hub-and-spoke configurations. Keep in mind that orderwire is not protected in ring topologies such as bidirectional line switched rings (BLSRs) and path protection configurations. Caution Do not configure orderwire loops. Orderwire loops cause feedback that disables the orderwire channel. The ONS 15454 implementation of both local and express orderwire is broadcast in nature. The line acts as a party line. Anyone who picks up the orderwire channel can communicate with all other participants on the connected orderwire subnetwork. The local orderwire party line is separate from the express orderwire party line. Up to four OC-N facilities for each local and express orderwire are provisionable as orderwire paths. Note The OC3 IR 4/STM1 SH 1310 card does not support the express orderwire channel. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-31 Chapter 2 Common Control Cards 2.7.4 Power Monitoring The AIC-I supports selective dual tone multifrequency (DTMF) dialing for telephony connectivity, which causes one AIC-I card or all ONS 15454 AIC-I cards on the orderwire subnetwork to “ring.” The ringer/buzzer resides on the AIC-I. There is also a “ring” LED that mimics the AIC-I ringer. It flashes when a call is received on the orderwire subnetwork. A party line call is initiated by pressing *0000 on the DTMF pad. Individual dialing is initiated by pressing * and the individual four-digit number on the DTMF pad. Table 2-20 shows the pins on the orderwire connector that correspond to the tip and ring orderwire assignments. Table 2-20 Orderwire Pin Assignments RJ-11 Pin Number Description 1 Four-wire receive ring 2 Four-wire transmit tip 3 Two-wire ring 4 Two-wire tip 5 Four-wire transmit ring 6 Four-wire receive tip When provisioning the orderwire subnetwork, make sure that an orderwire loop does not exist. Loops cause oscillation and an unusable orderwire channel. Figure 2-10 shows the standard RJ-11 connectors used for orderwire ports. Use a shielded RJ-11 cable. Figure 2-10 RJ-11 Connector 61077 RJ-11 Pin 1 Pin 6 2.7.4 Power Monitoring The AIC-I card provides a power monitoring circuit that monitors the supply voltage of –48 VDC for presence, undervoltage, or overvoltage. 2.7.5 User Data Channel The user data channel (UDC) features a dedicated data channel of 64 kbps (F1 byte) between two nodes in an ONS 15454 network. Each AIC-I card provides two user data channels, UDC-A and UDC-B, through separate RJ-11 connectors on the front of the AIC-I card. Use an unshielded RJ-11 cable. Each UDC can be routed to an individual optical interface in the ONS 15454. For UDC circuit provisioning, refer to the “Create Circuits and VT Tunnels” chapter in the Cisco ONS 15454 Procedure Guide. The UDC ports are standard RJ-11 receptacles. Table 2-21 lists the UDC pin assignments. Cisco ONS 15454 Reference Manual, R8.5.x 2-32 78-18106-01 Chapter 2 Common Control Cards 2.7.6 Data Communications Channel Table 2-21 UDC Pin Assignments RJ-11 Pin Number Description 1 For future use 2 TXN 3 RXN 4 RXP 5 TXP 6 For future use 2.7.6 Data Communications Channel The DCC features a dedicated data channel of 576 kbps (D4 to D12 bytes) between two nodes in an ONS 15454 network. Each AIC-I card provides two DCCs, DCC-A and DCC-B, through separate RJ-45 connectors on the front of the AIC-I card. Use a shielded RJ-45 cable. Each DCC can be routed to an individual optical interface in the ONS 15454. The DCC ports are standard RJ-45 receptacles. Table 2-22 lists the DCC pin assignments. Table 2-22 DCC Pin Assignments RJ-45 Pin Number Description 1 TCLKP 2 TCLKN 3 TXP 4 TXN 5 RCLKP 6 RCLKN 7 RXP 8 RXN Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 2-33 Chapter 2 Common Control Cards 2.7.6 Data Communications Channel Cisco ONS 15454 Reference Manual, R8.5.x 2-34 78-18106-01 CH A P T E R 3 Electrical Cards This chapter describes Cisco ONS 15454 electrical card features and functions. For installation and card turn-up procedures, refer to the Cisco ONS 15454 Procedure Guide. For information on the electrical interface assemblies (EIAs), see the “1.5 Electrical Interface Assemblies” section on page 1-15. Chapter topics include: • 3.1 Electrical Card Overview, page 3-1 • 3.2 Bit Error Rate Testing, page 3-4 • 3.3 EC1-12 Card, page 3-5 • 3.4 DS1-14 and DS1N-14 Cards, page 3-7 • 3.5 DS1/E1-56 Card, page 3-10 • 3.6 DS3-12 and DS3N-12 Cards, page 3-13 • 3.7 DS3/EC1-48 Card, page 3-16 • 3.8 DS3i-N-12 Card, page 3-19 • 3.9 DS3-12E and DS3N-12E Cards, page 3-21 • 3.10 DS3XM-6 Card, page 3-25 • 3.11 DS3XM-12 Card, page 3-27 3.1 Electrical Card Overview Each card is marked with a symbol that corresponds to a slot (or slots) on the ONS 15454 shelf assembly. The cards are then installed into slots displaying the same symbols. See the “1.17 Cards and Slots” section on page 1-71 for a list of slots and symbols. 3.1.1 Card Summary Table 3-1 lists the Cisco ONS 15454 electrical cards. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-1 Chapter 3 Electrical Cards 3.1.1 Card Summary Table 3-1 Cisco ONS 15454 Electrical Cards Card Name Description For Additional Information EC1-12 The EC1-12 card provides 12 Telcordia-compliant, GR-253 STS-1 electrical ports per card. Each port operates at 51.840 Mbps over a single 750-ohm, 728A or equivalent coaxial span. See the “3.3 EC1-12 Card” section on page 3-5. DS1-14 The DS1-14 card provides 14 Telcordia-compliant GR-499 DS-1 ports. Each port operates at 1.544 Mbps over a 100-ohm, twisted-pair copper cable. See the “3.4 DS1-14 and DS1N-14 Cards” section on page 3-7. DS1N-14 The DS1N-14 card supports the same features as the See the “3.4 DS1-14 and DS1-14 card but can also provide 1:N (N <= 5) DS1N-14 Cards” section on protection. page 3-7. DS1/E1-56 The DS1/E1-56 card provides 56 Telcordiacompliant, GR-499 DS-1 ports per card, or 56 E1 ports per card. Each port operates at 1.544 Mbps (DS-1) or 2.048 Mbps (E1). The DS1/E1-56 card operates as a working or protect card in 1:N protection schemes, where N <= 2. See the “3.5 DS1/E1-56 Card” section on page 3-10. DS3-12 The DS3-12 card provides 12 Telcordia-compliant GR-499 DS-3 ports per card. Each port operates at 44.736 Mbps over a single 75-ohm, 728A or equivalent coaxial span. See the “3.6 DS3-12 and DS3N-12 Cards” section on page 3-13. DS3N-12 The DS3N-12 card supports the same features as the See the “3.6 DS3-12 and DS3-12 but can also provide 1:N (N <= 5) DS3N-12 Cards” section on protection. page 3-13. DS3/EC1-48 The DS3/EC1-48 provides 48 Telcordia-compliant ports per card. Each port operates at 44.736 Mbps over a single 75-ohm, 728A or equivalent coaxial span. DS3i-N-12 See the “3.8 DS3i-N-12 Card” The DS3i-N-12 card provides 12 ITU-T G.703, section on page 3-19 ITU-T G.704, and Telcordia GR-499-CORE compliant DS-3 ports per card. Each port operates at 44.736 Mbps over a 75-ohm coaxial cable. DS3-12E The DS3-12E card provides 12 Telcordia-compliant See the “3.9 DS3-12E and DS3N-12E Cards” section on ports per card. Each port operates at 44.736 Mbps page 3-21. over a single 75-ohm, 728A or equivalent coaxial span. The DS3-12E card provides enhanced performance monitoring functions. DS3N-12E The DS3N-12E card supports the same features as the DS3-12E but can also provide 1:N (N <= 5) protection. See the “3.7 DS3/EC1-48 Card” section on page 3-16. See the “3.9 DS3-12E and DS3N-12E Cards” section on page 3-21. Cisco ONS 15454 Reference Manual, R8.5.x 3-2 78-18106-01 Chapter 3 Electrical Cards 3.1.2 Card Compatibility Table 3-1 Cisco ONS 15454 Electrical Cards (continued) Card Name Description For Additional Information DS3XM-6 (Transmux) See the “3.10 DS3XM-6 Card” The DS3XM-6 card provides six Telcordiasection on page 3-25. compliant GR-499-CORE M13 multiplexing functions. The DS3XM-6 converts six framed DS-3 network connections to 28x6 or 168 VT1.5s. DS3XM-12 (Transmux) See the “3.11 DS3XM-12 Card” The DS3XM-12 card provides 12 Telcordiasection on page 3-27. compliant GR-499-CORE M13 multiplexing functions. The DS3XM-12 converts twelve framed DS-3 network connections to 28x12 or 168 VT1.5s. 3.1.2 Card Compatibility Table 3-2 lists the CTC software compatibility for each electrical card. See Table 2-4 on page 2-4 for a list of cross-connect cards that are compatible with each electrical card. Note Table 3-2 “Yes” indicates that this card is fully or partially supported by the indicated software release. Refer to the individual card reference section for more information about software limitations for this card. Electrical Card Software Release Compatibility Electrical Card R2.2.2 R3.0.1 R3.1 R3.2 R3.3 R3.4 R4.0 R4.1 R4.5 R4.6 R4.7 R5.0 R6.0 R7.0 R7.2 8.0 8.5 EC1-12 Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes DS1-14 Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes DS1N-14 Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes DS1/E1-56 — — — — — — — — — — — — Yes Yes Yes Yes Yes DS3-12 Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes DS3N-12 Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes DS3-12E Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes DS3N-12E Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes DS3XM-6 (Transmux) Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes DS3XM-12 (Transmux) — — — — — — — — — — — Yes Yes Yes Yes Yes Yes DS3/EC1-48 — — — — — — — — — — — Yes Yes Yes Yes Yes Yes DS3i-N-12 — — — — — — — Yes — (4.1.2) Yes — Yes Yes Yes Yes Yes Yes Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-3 Chapter 3 Electrical Cards 3.2 Bit Error Rate Testing 3.2 Bit Error Rate Testing The bit error rate testing (BERT) feature can be used to test the connectivity, error rate, and error count of the traffic running on an electrical input/output (I/O) card port. The BERT feature is currently supported for ONS 15454 DS1/E1-56 and DS3XM-12 electrical cards only. BERT is broadly classified into two components—Test Pattern Generator (TPG) and Test Pattern Monitor (TPM) and is called Test Pattern Generator and Monitor (TPGM) when referring to Test Pattern Generator and Monitor. TPG generates test patterns like PRBS15, PRBS20, PRBS23, QRSS and ATL1s0s (alternating ones and zeroes). TPM monitors test patterns like PRBS15, PRBS20, PRBS23, QRSS and ALT1s0s. TPG and TPM inject and monitor errors in the test pattern for both single bit and multirate (1.0E-3, 1.0E-4, 1.0E-5 and 1.0E-6) errors. TPGM-L enables test pattern generation and monitoring on the line side. This option is not available for the DS1 port in the DS3XM-12 card because you can configure DS1 port on the backplane side only. TPGM-B enables test pattern generation and monitoring on the backplane side. You can enable TPGM-B on a port only if the port has a bidirectional circuit. Note The port must be in Out-of-Service and Maintenance (OOS-MT) state before enabling TPGM-L or TPGM-B. OOS-MT state puts the circuit cross-connects to a service state. This service state does not interrupt traffic flow and allows loopbacks to be performed on the circuit. OOS-MT however, suppresses any alarms and conditions. Change the administrative state to IS, OOS, or IS-AINS when testing is complete. For information on how to set the port to OOS-MT state, see the “DLP-A230 Change a Circuit Service State” task in the Cisco ONS 15454 Procedure Guide, Release 8.5. Note To enable TPGM-L or TPGM-B on a DS1 port, the line framing type must be D4, ESF, or unframed. Note At any given time, you can enable BERT mode only on a single port of a card. The following table summarizes if BERT can be enabled on the line side or backplane side for DS1/E1-56 and DS3XM-12 electrical cards. Note “Yes” indicates that BERT can be enabled on the line side (TPGM-L) or backplane side (TPGM-B). Table 3-3 Enabling BERT on Line Side and Backplane Side DS1/E1-56 card TPGM-L TPGM-B DS1 Port Yes Yes DS1 Port No Yes DS3 Port Yes No DS3XM-12 card For information on how to enable BERT on the DS1/E1-56 and DS3XM-12 cards, see the Cisco ONS 15454 Procedure Guide, Release 8.5. Cisco ONS 15454 Reference Manual, R8.5.x 3-4 78-18106-01 Chapter 3 Electrical Cards 3.3 EC1-12 Card BERT Alarms The BERT feature can raise the following two alarms in CTC: • BERT_ENABL—Specifies that BERT feature is enabled. • BERT_SYNC_FAIL—Synchronization is necessary and occurs when the errors injected by the TPG reach the TPM and connectivity is established. The BERT_SYNC_FAIL alarm occurs when synchronization fails. Both the alarms are non-reportable conditions, non-service affecting, and no severity is associated with these two conditions. 3.3 EC1-12 Card Note For hardware specifications, see the “A.5.1 EC1-12 Card Specifications” section on page A-17. The EC1-12 card provides 12 Telcordia-compliant, GR-253 STS-1 electrical ports per card. Each port operates at 51.840 Mbps over a single 75-ohm, 728A or equivalent coaxial span. STS path selection for UNEQ-P, AIS-P, and bit error rate (BER) thresholds is done on the SONET ring interfaces (optical cards) in conjunction with the STS cross-connect. The EC1-12 terminates but does not select the 12 working STS-1 signals from the backplane. The EC1-12 maps each of the 12 received EC1 signals into 12 STS-1s with visibility into the SONET path overhead. An EC1-12 card can be 1:1 protected with another EC1-12 card but cannot protect more than one EC1-12 card. You must install the EC1-12 in an even-numbered slot to serve as a working card and in an odd-numbered slot to serve as a protect card. 3.3.1 EC1-12 Slots and Connectors You can install the EC1-12 card in Slots 1 to 6 or 12 to 17 on the ONS 15454. Each EC1-12 interface features DSX-level (digital signal cross-connect frame) outputs supporting distances up to 450 feet (137 meters) depending on facility conditions. See the “7.2 Electrical Card Protection and the Backplane” section on page 7-5 for more information about electrical card slot protection and restrictions. 3.3.2 EC1-12 Faceplate and Block Diagram Figure 3-1 shows the EC1-12 faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-5 Chapter 3 Electrical Cards 3.3.3 EC1-12 Hosted by XCVT, XC10G, or XC-VXC-10G Figure 3-1 EC1-12 Faceplate and Block Diagram EC1 12 FAIL ACT/STBY SF main STS1 Line Interface Unit x12 STS-12/ 12xSTS-1 Mux/Demux ASIC BTC ASIC B a c k p l a n e 61344 protect STS1 STS-1 Framer 3.3.3 EC1-12 Hosted by XCVT, XC10G, or XC-VXC-10G All 12 STS-1 payloads from an EC1-12 card are carried to the XCVT, XC10G, or XC-VXC-10G card where the payload is further aggregated for efficient transport. XCVT cards can host a maximum of 288 bidirectional STS-1s. The XC10G and XC-VXC-10G cards can host up to 1152 bidirectional STS-1s. 3.3.4 EC1-12 Card-Level Indicators Table 3-4 describes the three card-level LEDs on the EC1-12 card. Cisco ONS 15454 Reference Manual, R8.5.x 3-6 78-18106-01 Chapter 3 Electrical Cards 3.3.5 EC1-12 Port-Level Indicators Table 3-4 EC1-12 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the EC1-12 card processor is not ready. Replace the unit if the FAIL LED persists. Green ACT LED The green ACT LED indicates that the EC1-12 card is operational and ready to carry traffic. Amber SF LED The amber SF LED indicates a signal failure or condition such as loss of signal (LOS), loss of frame (LOF) or high BER on one or more card ports. 3.3.5 EC1-12 Port-Level Indicators You can obtain the status of the EC1-12 card ports by using the LCD screen on the ONS 15454 fan tray. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 3.4 DS1-14 and DS1N-14 Cards Note For hardware specifications, see the “A.5.2 DS1-14 and DS1N-14 Card Specifications” section on page A-18. The ONS 15454 DS1-14 card provides 14 Telcordia-compliant, GR-499 DS-1 ports. Each port operates at 1.544 Mbps over a 100-ohm, twisted-pair copper cable. The DS1-14 card can function as a working or protect card in 1:1 protection schemes and as a working card in 1:N protection schemes. Each DS1-14 port has digital signal cross-connect frame (DSX)-level outputs supporting distances up to 655 feet (200 meters). The DS1-14 card supports 1:1 protection. The DS1-14 can be a working card in a 1:N protection scheme with the proper backplane EIA and wire-wrap or AMP Champ connectors. You can also provision the DS1-14 to monitor for line and frame errors in both directions. You can group and map DS1-14 card traffic in STS-1 increments to any other card in an ONS 15454 except DS-3 cards. Each DS-1 is asynchronously mapped into a SONET VT1.5 payload and the card carries a DS-1 payload intact in a VT1.5. For performance monitoring purposes, you can gather bidirectional DS-1 frame-level information (LOF, parity errors, cyclic redundancy check [CRC] errors, and so on). 3.4.1 DS1N-14 Features and Functions The DS1N-14 card supports the same features as the DS1-14 card in addition to enhanced protection schemes. The DS1N-14 is capable of 1:N (N <= 5) protection with the proper backplane EIA and wire-wrap or AMP Champ connectors. The DS1N-14 card can function as a working or protect card in 1:1 or 1:N protection schemes. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-7 Chapter 3 Electrical Cards 3.4.2 DS1-14 and DS1N-14 Slot Compatibility If you use the DS1N-14 as a standard DS-1 card in a 1:1 protection group, you can install the DS1N-14 card in Slots 1 to 6 or 12 to 17 on the ONS 15454. If you use the card’s 1:N functionality, you must install a DS1N-14 card in Slots 3 and 15. Each DS1N-14 port features DS-n-level outputs supporting distances of up to 655 feet (200 meters) depending on facility conditions. 3.4.2 DS1-14 and DS1N-14 Slot Compatibility You can install the DS1-14 card in Slots 1 to 6 or 12 to 17 on the ONS 15454. 3.4.3 DS1-14 and DS1N-14 Faceplate and Block Diagram Figure 3-2 shows the DS1-14 faceplate and the block diagram of the card. Figure 3-2 DS1-14 Faceplate and Block Diagram DS114 FAIL ACT/STBY SF Protection Relay Matrix 14 Line Interface Units STS1 to 14 DS1 Mapper DRAM Cross Connect Matrix BTC ASIC B a c k p l a n e FLASH 61345 uP STS-1 / STS-12 Mux/Demux ASIC 33678 12931 Figure 3-3 shows the DS1N-14 faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 3-8 78-18106-01 Chapter 3 Electrical Cards 3.4.4 DS1-14 and DS1N-14 Hosted by XCVT, XC10G, or XC-VXC-10G Figure 3-3 DS1N-14 Faceplate and Block Diagram DS1N14 FAIL ACT/STBY SF Protection Relay Matrix 14 Line Interface Units STS1 to 14 DS1 Mapper STS-1 / STS-12 Mux/Demux ASIC BTC ASIC B a c k p l a n e DRAM FLASH 61346 uP 33678 12931 3.4.4 DS1-14 and DS1N-14 Hosted by XCVT, XC10G, or XC-VXC-10G All 14 VT1.5 payloads from DS1-14 and DSIN-14 cards are carried in a single STS-1 to the XCVT, XC10G, or XC-VXC-10G cards, where the payload is further aggregated for efficient STS-1 transport. The XC10G and XCVT cards manage up to 336 bidirectional VT1.5 ports. The XC-VXC-10G card can manage up to 2688 bidirectional VT1.5 ports 3.4.5 DS1-14 and DS1N-14 Card-Level Indicators Table 3-5 describes the three card-level LEDs on the DS1-14 and DS1N-14 card faceplates. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-9 Chapter 3 Electrical Cards 3.4.6 DS1-14 and DS1N-14 Port-Level Indicators Table 3-5 DS1-14 and DS1N-14 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card processor is not ready. Replace the card if the red FAIL LED persists. ACT/STBY LED The green/amber ACT/STBY LED indicates whether the card is operational and ready to carry traffic (green) or in standby mode (amber). Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on one or more card ports. 3.4.6 DS1-14 and DS1N-14 Port-Level Indicators You can obtain the status of the DS1-14 and DS1N-14 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 3.5 DS1/E1-56 Card Note For hardware specifications, see the “A.5.3 DS1/E1-56 Card Specifications” section on page A-19. The ONS 15454 DS1/E1-56 card provides 56 Telcordia-compliant, GR-499 DS-1 ports per card, or 56 E1 ports per card. Each port operates at 1.544 Mbps (DS-1) or 2.048 Mbps (E1). The DS1/E1-56 card operates as a working or protect card in 1:N protection schemes, where N <= 2. The DS1/E1-56 card can be used with the XCVT, XC10G, or XC-VXC-10G cross-connect cards. Note Caution The DS1/E1-56 card does not support VT-2 (virtual tributary-2) circuit creation on E1 ports. When a protection switch moves traffic from the active (or working) DS1/E1-56 card to the standby (or protect) DS1/E1-56 card, ports on the now standby (or protect) card cannot be moved to Out of Service state. Traffic is dropped if the ports are in Out of Service state. 3.5.1 DS1/E1-56 Slots and Connectors For SONET applications, the DS1/E1-56 card requires a high-density (HD) shelf (15454-SA-HD), UBIC EIA, and Software Release 6.0 or greater. Note The UBIC-H EIA supports the termination of both DS-1 and E-1 signals when used with the appropriate cables. The UBIC-V EIA only supports the termination of DS-1 signals. Cisco ONS 15454 Reference Manual, R8.5.x 3-10 78-18106-01 Chapter 3 Electrical Cards 3.5.2 DS1/E1-56 Faceplate and Block Diagram Note The DS1/E1-56 card supports an errorless software-initiated cross-connect card switch when used in a shelf equipped with XC-VXC-10G and TCC2/TCC2P cards. You can install the DS1/E1-56 card in Slots 1 to 3 or 15 to 17 on the ONS 15454, but installing this card in certain slots will block the use of other slots. Table 3-6 shows which slots become unusable for other electrical cards when the DS1/E1-56 card is installed in a particular slot. Table 3-6 DS1/E1-56 Slot Restrictions Slot Additional Unusable Slots for Electrical Cards 1 5 and 6 2 3 or 4 (except another DS1/E1-56 protect card can be installed in Slot 3) 3 — 15 — 16 14 and 15 (except another DS1/E1-56 protect card can be installed in Slot 15) 17 12 and 13 With the proper backplane EIA, the card supports SCSI (UBIC) connectors. See the “7.2 Electrical Card Protection and the Backplane” section on page 7-5 for more information about electrical card slot protection and restrictions. Connectivity, error rate, and error count of the traffic running on an Electrical IO card ports can be tested by using BERT. For more information on BERT, see 3.2 Bit Error Rate Testing, page 3-4. 3.5.2 DS1/E1-56 Faceplate and Block Diagram Figure 3-4 shows the DS1/E1-56 faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-11 Chapter 3 Electrical Cards 3.5.3 DS1/E1-56 Card-Level Indicators Figure 3-4 DS1/E1-56 Faceplate and Block Diagram DS1 Analog x8 ports DS1 Analog x8 ports DS1/E1 Octal LIU #1 DS1/E1 Octal LIU #2 622MHz TSWC Ref Clock Synth DS1 Digital x8 ports 38MHz Ref’s DS1 Digital x8 ports U XFMR/ B DS1 I MUX C x56 ports STS-12 Data Agere Ultramapper LIUs 3 thru 6 not shown DS1 Analog x8 ports DS1/E1 Octal LIU #7 MAIN Data 4 Bit 155Mhz STS-12 B 4 Bit PROT 155Mhz a Data STS-12 c k Stingray p FPGA l a n e SCL LINK to TCC DS1 Digital x8 ports 131201 AD BUS to PROC 3.5.3 DS1/E1-56 Card-Level Indicators The DS1/E1-56 card has three card-level LED indicators (Table 3-7). Cisco ONS 15454 Reference Manual, R8.5.x 3-12 78-18106-01 Chapter 3 Electrical Cards 3.5.4 DS1/E1-56 Port-Level Indicators Table 3-7 DS1/E1-56 Card-Level Indicators Card-Level Indicators Description Red FAIL LED Indicates that the card processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists in flashing. ACT/STBY LED When the ACT/STBY LED is green, the card is operational and ready to carry traffic. When the ACT/STBY LED is amber, the card is operational and in standby (protect) mode. Green (Active) Amber (Standby) Amber SF LED Indicates a signal failure or condition such as LOS or LOF on one or more card ports. 3.5.4 DS1/E1-56 Port-Level Indicators You can obtain the status of the DS1/E1-56 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 3.6 DS3-12 and DS3N-12 Cards Note For hardware specifications, see the “A.5.5 DS3-12 and DS3N-12 Card Specifications” section on page A-21. Note Any new features that are available as part of this software release are not enabled for this card. The ONS 15454 DS3-12 card provides 12 Telcordia-compliant, GR-499 DS-3 ports per card. Each port operates at 44.736 Mbps over a single 75-ohm 728A or equivalent coaxial span. The DS3-12 card operates as a working or protect card in 1:1 protection schemes and as a working card in 1:N protection schemes. The DS3-12 card supports 1:1 protection with the proper backplane EIA. EIAs are available with BNC, SMB, or SCSI (UBIC) connectors. Caution When a protection switch moves traffic from the DS3-12 working/active card to the DS3-12 protect/standby card, ports on the now active/standby card cannot be taken out of service. Lost traffic can result if you take a port out of service, even if the DS3-12 standby card no longer carries traffic. Other than protection capabilities, the DS3-12 and DS3N-12 cards are identical. The DS3N-12 can operate as the protect card in a 1:N (N <= 5) DS3 protection group. It has additional circuitry that is not present on the basic DS3-12 card that allows it to protect up to five working DS3-12 cards. The basic DS3-12 card can only function as the protect card for one other DS3-12 card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-13 Chapter 3 Electrical Cards 3.6.1 DS3-12 and DS3N-12 Slots and Connectors 3.6.1 DS3-12 and DS3N-12 Slots and Connectors You can install the DS3-12 or DS3N-12 card in Slots 1 to 6 or 12 to 17 on the ONS 15454. Each DS3-12 or DS3N-12 card port features DSX-level outputs supporting distances up to 137 meters (450 feet) depending on facility conditions. With the proper backplane EIA, the card supports BNC or SMB connectors. See the “7.2 Electrical Card Protection and the Backplane” section on page 7-5 for more information about electrical card slot protection and restrictions. 3.6.2 DS3-12 and DS3N-12 Faceplate and Block Diagram Figure 3-5 shows the DS3-12 faceplate and a block diagram of the card. Figure 3-5 DS3-12 Faceplate and Block Diagram DS3 12 FAIL ACT/STBY Protection Relay Matrix 12 Line Interface Units DS3A ASIC BTC ASIC B a c k p l a n e 61347 SF 33678 12931 Cisco ONS 15454 Reference Manual, R8.5.x 3-14 78-18106-01 Chapter 3 Electrical Cards 3.6.3 DS3-12 and DS3N-12 Card-Level Indicators Figure 3-6 shows the DS3N-12 faceplate and a block diagram of the card. Figure 3-6 DS3N-12 Faceplate and Block Diagram DS3N 12 FAIL ACT/STBY Protection Relay Matrix 12 Line Interface Units DS3A ASIC BTC ASIC B a c k p l a n e 61348 SF 1345987 3.6.3 DS3-12 and DS3N-12 Card-Level Indicators Table 3-8 describes the three card-level LEDs on the DS3-12 and DS3N-12 card faceplates. Table 3-8 DS3-12 and DS3N-12 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card processor is not ready. Replace the card if the red FAIL LED persists. ACT/STBY LED When the ACT/STBY LED is green, the card is operational and ready to carry traffic. When the ACT/STBY LED is amber, the card is operational and in standby (protect) mode. Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as port LOS. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-15 Chapter 3 Electrical Cards 3.6.4 DS3-12 and DS3N-12 Port-Level Indicators 3.6.4 DS3-12 and DS3N-12 Port-Level Indicators You can find the status of the 12 DS3-12 and 12 DS3N-12 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 3.7 DS3/EC1-48 Card Note For hardware specifications, see the “A.5.4 DS3/EC1-48 Card Specifications” section on page A-20. The ONS 15454 DS3/EC1-48 card provides 48 Telcordia-compliant, GR-499 DS-3 ports per card. Each port operates at 44.736 Mbps over a single 75-ohm 728A or equivalent coaxial span. The DS3/EC1-48 card operates as a working or protect card in 1:N protection schemes, where N <= 2. Caution When a protection switch moves traffic from the DS3/EC1-48 working/active card to the DS3/EC1-48 protect/standby card, ports on the now active/standby card cannot be taken out of service. Lost traffic can result if you take a port out of service, even if the DS3/EC1-48 standby card no longer carries traffic. 3.7.1 DS3/EC1-48 Slots and Connectors For SONET applications, the DS3/EC1-48 card requires an HD shelf (15454-SA-HD) and EIA (UBIC, MiniBNC); Software Release 5.0 or greater; and XC10G or XC-VXC-10G cards. Note The DS3/EC1-48 card supports an errorless software-initiated cross-connect card switch when used in a shelf equipped with XC-VXC-10G and TCC2/TCC2P cards. You can install the DS3/EC1-48 card in Slots 1 to 3 or 15 to 17 on the ONS 15454, but installing this card in certain slots will block the use of other slots. Table 3-9 shows which slots become unusable for other electrical cards when the DS3/EC1-48 card is installed in a particular slot. Table 3-9 Caution DS3/EC1-48 Slot Restrictions Slot Additional Unusable Slots for Electrical Cards 1 5 and 6 2 3 or 4 (except another DS3/EC1-48 card can be installed in Slot 3) 3 — 15 — 16 14 and 15 (except another DS3/EC1-48 card can be installed in Slot 15) 17 12 and 13 Do not install low-density DS-1 cards in the same side of the shelf as DS3/EC1-48 cards. Cisco ONS 15454 Reference Manual, R8.5.x 3-16 78-18106-01 Chapter 3 Electrical Cards 3.7.2 DS3/EC1-48 Faceplate and Block Diagram Caution Do not install a DS3/EC1-48 card in Slots 1 or 2 if you have installed an MXP_2.5G_10G card in Slot 3. Likewise, do not install a DS3/EC1-48 card in Slots 16 or 17 if you have installed an MXP_2.5G_10G card in Slot 15. If you do, the cards will interact and cause DS-3 bit errors. With the proper backplane EIA, the card supports BNC or SCSI (UBIC) connectors. See the “7.2 Electrical Card Protection and the Backplane” section on page 7-5 for more information about electrical card slot protection and restrictions. 3.7.2 DS3/EC1-48 Faceplate and Block Diagram Figure 3-7 shows the DS3/EC1-48 faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-17 Chapter 3 Electrical Cards 3.7.3 DS3/EC1-48 Card-Level Indicators Figure 3-7 DS3/EC1-48 Faceplate and Block Diagram DS3 EC1 48 FAIL ACT/STBY Main & Protect SCL Bus’s SF MAIN IBPIA ASIC (UBIC-V, UBIC-H, or HD MiniBNC) Transformers & Protection Mux/Relays 4x DS3/EC1 Framer/ Mapper/ LIU STS-48 Mapper FPGA PROTECT IBPIA ASIC 115955 48 DS3/EC1 Ports B a c k p l a n e Processor 3.7.3 DS3/EC1-48 Card-Level Indicators The DS3/EC1-48 card has three card-level LED indicators (Table 3-10). Cisco ONS 15454 Reference Manual, R8.5.x 3-18 78-18106-01 Chapter 3 Electrical Cards 3.7.4 DS3/EC1-48 Port-Level Indicators Table 3-10 DS3/EC1-48 Card-Level Indicators Card-Level Indicators Description Red FAIL LED Indicates that the card processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists in flashing. ACT/STBY LED When the ACT/STBY LED is green, the card is operational and ready to carry traffic. When the ACT/STBY LED is amber, the card is operational and in standby (protect) mode. Green (Active) Amber (Standby) Amber SF LED Indicates a signal failure or condition such as LOS or LOF on one or more card ports. 3.7.4 DS3/EC1-48 Port-Level Indicators You can obtain the status of the DS3/EC1-48 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 3.8 DS3i-N-12 Card Note For hardware specifications, see the “A.5.6 DS3i-N-12 Card Specifications” section on page A-23. The 12-port ONS 15454 DS3i-N-12 card provides 12 ITU-T G.703, ITU-T G.704, and Telcordia GR-499-CORE compliant DS-3 ports per card. Each port operates at 44.736 Mbps over a 75-ohm coaxial cable. The DS3i-N-12 card supports 1:1 or 1:N protection with the proper backplane EIA. The DS3i-N-12 card works with the XCVT, XC10G, and XC-VXC-10G cross-connect cards. Four sets of three adjacent DS-3 signals (Port 1 through Port 3, Port 4 through Port 6, Port 7 through Port 9, and Port 10 through Port 12) are mapped to VC3s into a VC4 and transported as an STC-3c. The DS3i-N-12 can also aggregate DS3 and E1 traffic and transport it between SONET and SDH networks through AU4/STS 3 trunks, with the ability to add and drop DS3s to an STS3 trunk at intermediate nodes. 3.8.1 DS3i-N-12 Slots and Connectors You can install the DS3i-N-12 card in Slots 1 to 6 and 12 to 17. The DS3i-N-12 can operate as the protect card in a 1:N (N <= 5) DS-3 protection group on a half-shelf basis, with protection cards in Slots 3 and 15. It has circuitry that allows it to protect up to five working DS3i-N-12 cards. With the proper backplane EIA, the card supports BNC or SMB connectors. See the “7.2 Electrical Card Protection and the Backplane” section on page 7-5 for more information about electrical card slot protection and restrictions. Figure 3-8 shows the DS3i-N-12 faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-19 Chapter 3 Electrical Cards 3.8.1 DS3i-N-12 Slots and Connectors Figure 3-8 DS3I- N 12 DS3i-N-12 Faceplate and Block Diagram main DS3-m1 protect DS3-p1 Line Interface Unit #1 FAIL ACT/STBY SF DS3 ASIC BERT FPGA main DS3-m12 protect DS3-p12 Line Interface Unit #1 OHP FPGA BTC ASIC B a c k p l a n e uP bus SDRAM Flash 134365 Processor The following list summarizes the DS3i-N-12 card features: • Provisionable framing format (M23, C-bit, or unframed) • Autorecognition and provisioning of incoming framing • VC-3 payload mapping as per ITU-T G.707, mapped into VC-4 and transported as STS-3c • Idle signal (“1100”) monitoring as per Telcordia GR-499-CORE • P-bit monitoring • C-bit parity monitoring • X-bit monitoring • M-bit monitoring • F-bit monitoring • Far-end block error (FEBE) monitoring • Far-end alarm and control (FEAC) status and loop code detection • Path trace byte support with TIM-P alarm generation Cisco ONS 15454 Reference Manual, R8.5.x 3-20 78-18106-01 Chapter 3 Electrical Cards 3.8.2 DS3i-N-12 Card-Level Indicators 3.8.2 DS3i-N-12 Card-Level Indicators Table 3-11 describes the three LEDs on the DS3i-N-12 card faceplate. Table 3-11 DS3i-N-12 Card-Level Indicators Card-Level LEDs Description Red FAIL LED Indicates that the card processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists in flashing. ACT/STBY LED When the ACT/STBY LED is green, the DS3i-N-12 card is operational and ready to carry traffic. When the ACT/STBY LED is amber, the DS3i-N-12 card is operational and in standby (protect) mode. Green (Active) Amber (Standby) Amber SF LED Indicates a signal failure or condition such as LOS or LOF on one or more card ports. 3.8.3 DS3i-N-12 Port-Level Indicators You can find the status of the DS3i-N-12 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. 3.9 DS3-12E and DS3N-12E Cards Note For hardware specifications, see the “A.5.7 DS3-12E and DS3N-12E Card Specifications” section on page A-24. The ONS 15454 DS3-12E card provides 12 Telcordia-compliant GR-499 DS-3 ports per card. Each port operates at 44.736 Mbps over a single 75-ohm 728A or equivalent coaxial span. The DS3-12E card provides enhanced performance monitoring functions. The DS3-12E can detect several different errored logic bits within a DS3 frame. This function allows the ONS 15454 to identify a degrading DS3 facility caused by upstream electronics (DS3 Framer). In addition, DS3 frame format autodetection and J1 path trace are supported. By monitoring additional overhead in the DS3 frame, subtle network degradations can be detected. The following list summarizes DS3-12E card features: • Provisionable framing format M23, C-bit or unframed • Autorecognition and provisioning of incoming framing • P-bit monitoring • C-bit parity monitoring • X-bit monitoring • M-bit monitoring • F-bit monitoring Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-21 Chapter 3 Electrical Cards 3.9.1 DS3-12E and DS3N-12E Slots and Connectors • FEBE monitoring • FEAC status and loop code detection • Path trace byte support with TIM-P alarm generation The DS3-12E supports a 1:1 protection scheme, meaning it can operate as the protect card for one other DS3-12E card. The DS3N-12E can operate as the protect card in a 1:N (N <= 5) DS3 protection group. It has additional circuitry not present on the basic DS3-12E card that allows it to protect up to five working DS3-12E cards. The basic DS3-12E card can only function as the protect card for one other DS3-12E card. 3.9.1 DS3-12E and DS3N-12E Slots and Connectors You can install the DS3-12E and DS3N-12E cards in Slots 1 to 6 or 12 to 17 on the ONS 15454. Each DS3-12E and DS3N-12E port features DSX-level outputs supporting distances up to 137 meters (450 feet). With the proper backplane EIA, the card supports BNC or SMB connectors. See the “7.2 Electrical Card Protection and the Backplane” section on page 7-5 for more information about electrical card slot protection and restrictions. 3.9.2 DS3-12E Faceplate and Block Diagram Figure 3-9 shows the DS3-12E faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 3-22 78-18106-01 Chapter 3 Electrical Cards 3.9.2 DS3-12E Faceplate and Block Diagram Figure 3-9 DS3-12E Faceplate and Block Diagram DS3 12E FAIL ACT SF main DS3-m1 protect DS3-p1 Line Interface Unit #1 DS3 ASIC BERT FPGA main DS3-m12 protect DS3-p12 Line Interface Unit #1 OHP FPGA BTC ASIC B a c k p l a n e Processor SDRAM Flash 61349 uP bus Figure 3-10 shows the DS3N-12E faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-23 Chapter 3 Electrical Cards 3.9.3 DS3-12E and DS3N-12E Card-Level Indicators Figure 3-10 DS3N-12E Faceplate and Block Diagram DS3 N 12E FAIL ACT/STBY SF main DS3-m1 protect DS3-p1 Line Interface Unit #1 DS3 ASIC BERT FPGA main DS3-m12 protect DS3-p12 Line Interface Unit #1 OHP FPGA BTC ASIC B a c k p l a n e Processor SDRAM Flash 61350 uP bus 3.9.3 DS3-12E and DS3N-12E Card-Level Indicators Table 3-12 describes the three card-level LEDs on the DS3-12E and DS3N-12E card faceplates. Table 3-12 DS3-12E and DS3N-12E Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card processor is not ready. Replace the card if the red FAIL LED persists. ACT/STBY LED When the ACT/STBY LED is green, the card is operational and ready to carry traffic. When the ACT/STBY LED is amber, the card is operational and in standby (protect) mode. Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as port LOS or AIS. Cisco ONS 15454 Reference Manual, R8.5.x 3-24 78-18106-01 Chapter 3 Electrical Cards 3.9.4 DS3-12E and DS3N-12E Port-Level Indicators 3.9.4 DS3-12E and DS3N-12E Port-Level Indicators You can find the status of the DS3-12E and DS3N-12E card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to quickly view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 3.10 DS3XM-6 Card Note For hardware specifications, see the “A.5.9 DS3XM-6 Card Specifications” section on page A-26. The DS3XM-6 card, commonly referred to as a transmux card, provides six Telcordia-compliant, GR-499-CORE M13 multiplexing ports. The DS3XM-6 converts six framed DS-3 network connections to 28 x6 or 168 VT1.5s. DS3XM-6 cards operate at the VT1.5 level. 3.10.1 DS3XM-6 Slots and Connectors The DS3XM-6 card supports 1:1 protection with the proper backplane EIA. EIAs are available with BNC or SMB connectors. You can install the DS3XM-6 in Slots 1 to 6 or 12 to 17. Each DS3XM-6 port features DSX-level outputs supporting distances up to 137 meters (450 feet) depending on facility conditions. See “7.2 Electrical Card Protection and the Backplane” section on page 7-5 for more information about electrical card slot protection and restrictions. 3.10.2 DS3XM-6 Faceplate and Block Diagram Figure 3-11 shows the DS3XM-6 faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-25 Chapter 3 Electrical Cards 3.10.3 DS3XM-6 Hosted By XCVT, XC10G, or XC-VXC-10G Figure 3-11 DS3XM-6 Faceplate and Block Diagram DS3XM 6 FAIL ACT SF Mapper unit Protection Relay Matrix 6 x Line Interface Units 6 x M13 Units DRAM 6 STS-1 / STS-12 Mux/Demux ASIC FLASH BTC ASIC B a c k p l a n e DC/DC unit 61351 uP 6 STS1 to 28 DS1 Mapper 1345987 3.10.3 DS3XM-6 Hosted By XCVT, XC10G, or XC-VXC-10G The DS3XM-6 card works in conjunction with the XCVT card. A single DS3XM-6 can demultiplex six DS-3 signals into 168 VT1.5s that the XCVT card then manages and cross connects. XCVT cards host a maximum of 336 bidirectional VT1.5s on two DS3XM-6 cards. In most network configurations, two DS3XM-6 cards are paired together as working and protect cards. 3.10.4 DS3XM-6 Card-Level Indicators Table 3-13 describes the three card-level LEDs on the DS3XM-6 card faceplate. Cisco ONS 15454 Reference Manual, R8.5.x 3-26 78-18106-01 Chapter 3 Electrical Cards 3.10.5 DS3XM-6 Port-Level Indicators Table 3-13 DS3XM-6 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card processor is not ready. Replace the card if the red FAIL LED persists. ACT/STBY LED When the ACT/STBY LED is green, the DS3XM-6 card is operational and ready to carry traffic. When the ACT/STBY LED is amber, the DS3XM-6 card is operational and in standby in a 1:1 protection group. Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BER on one or more card ports. 3.10.5 DS3XM-6 Port-Level Indicators You can find the status of the six DS3XM-6 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to quickly view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 3.11 DS3XM-12 Card Note For hardware specifications, see the “A.5.8 DS3XM-12 Card Specifications” section on page A-25. The DS3XM-12 card, commonly referred to as a transmux card, provides twelve Telcordia-compliant, GR-499-CORE M13 multiplexing ports. The DS3XM-12 converts up to 12 framed DS-3 network connections to 12 x 28 VT1.5s. 3.11.1 Backplane Configurations The DS3XM-12 card has 12 framed DS-3 physical ports (known as “ported” mode). The card also supports a maximum of 12 “portless” DS3-mapped STS1 interfaces depending on the type of cross-connect used. Each physical port corresponds to two portless ports. If a circuit is provisioned to a physical port, its associated portless pair becomes unavailable and vice versa. See the “11.4 Portless Transmux” section on page 11-15 for more information. The DS3XM-12 card is compatible with the XCVT, XC10G, and XC-VXC-10G cross-connect cards. Note Caution The DS3XM-12 card supports an errorless software-initiated cross-connect card switch when used in a shelf equipped with XC-VXC-10G and TCC2/TCC2P cards. During an upgrade of the DS3XM-6 card to DS3XM-12 card, the DS-3XM-12 card (in slots 1 to 5) encounters an insufficient cable loss of margin when the LBO setting on the DS-3 input ports are set between 225 to 450 feet cable lengths. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-27 Chapter 3 Electrical Cards 3.11.2 Ported Mode The DS3XM-12 supports three different backplane throughput configurations: • STS-48 when an XC10G or XC-VXC-10G card is used. This configuration supports the OC-48 rate in any slot. • STS-48 for the Slots 5, 6, 12, and 13 when an XCVT card is used. • STS-12 for Slot 1 through 4, and 7 through 12 slots when an XCVT card is used. This configuration is bandwidth-limiting in the portless mode of operation. The backplane throughput configuration is selected in CTC card view using the Maintenance > Card tab. 3.11.2 Ported Mode The “ported” mode supports up to 12 framed DS-3 bidirectional mapped signals to each DS3XM-12 card, where the traffic is demultiplexed and mapped into a VT1.5 payload. This payload is then mapped and multiplexed up to a bidirectional STS-1. 3.11.3 Portless Mode The “portless” mode allows for IXC hand off connections through a standard SONET fiber optical interface with DS-3-mapped STS-1s as a payload. This physical connection is accomplished with any of the OC-N cards. The system cross-connect grooms the DS-3 mapped STS1 traffic to the appropriate DS3XM-12 card, where the traffic is demultiplexed and mapped into a VT1.5 payload. This payload is then mapped and multiplexed up to a higher rate STS-1. See the “11.4 Portless Transmux” section on page 11-15 for more information. 3.11.4 Shelf Configurations The DS3XM-12 card supports the XCVT, XC10G, and XC-VXC-10G cards. The DS3XM-12 card is supported in any of the multiservice slots (Slots 1 through 6 and 12 through 17). The DS3XM-12 card operates at the VT1.5 level and supports a maximum of 6 or 12 ports of “portless” (DS-3-mapped STS1s) interface, depending on the shelf configuration (see Table 3-14). Table 3-14 Caution DS3XM-12 Shelf Configurations Port Maximums Slots 1 through 4, and 14 through 17 (XCVT Card) Slots 5, 6, 12, and 13 (XCVT, XC10G, or XC-VXC-10G Cards) XC10G/XC-VXC-10G Shelf (any multiservice slot) Portless Ports 6 12 12 Ported Ports 12 12 12 Do not install low-density DS-1 cards in the same side of the shelf as DS3XM-12 cards. Cisco ONS 15454 Reference Manual, R8.5.x 3-28 78-18106-01 Chapter 3 Electrical Cards 3.11.5 Protection Modes 3.11.5 Protection Modes The DS3XM-12 card supports 1:1 and 1:N protection groups, where N <= 5. However, N <= 7 if one of the following conditions is true: • Only portless connections are used. • A combination of ported and portless connections is used but all the ported cards being protected are on the same side of the chassis as the protecting card. These protection groups can be implemented in the ONS 15454 SONET platform for both the A and B sides and do not require a special protect card. In 1:N protection, the protect card must be in Slot 3 or 15. In 1:1 protection, the working and protect cards must be in adjacent slots. The protection switches cause a traffic hit of no more than 50 ms. See the “7.2 Electrical Card Protection and the Backplane” section on page 7-5 for more information about electrical card slot protection and restrictions. In 1:1 or 1:N protection group with DS3XM12 cards having different backplane bandwidths, when a protection switch moves traffic from the working/active card to the protect/standby card or vice versa, it causes a traffic hit of greater than 50ms. 3.11.6 Card Features Table 3-15 summarizes the DS3XM-12 features. Table 3-15 DS3XM-12 Features Feature Description Protection 1:1 and 1:N protection (“ported” and “portless”) Upgrade Performance Monitoring Loopbacks • Errorless software upgrade • In-service upgrade of legacy DS3XM-6 to DS3XM-12 (> 60 ms hit) • DS-3 M2-3 near-end performance monitoring (PM) parameters • DS-3 C-bit near end and far end PM parameters • DS-1 near end PM parameters • DS-1 Extended Super Frame (ESF) PM far end parameters based on FDL PRM messages • 1989 AT&T TR 54016 DS1 ESF PM • SPRM and NPRM DS1 PM parameters • DS3 terminal and facility • DS1 facility • DS1 terminal • FEAC based DS1 and DS3 loopbacks (TX and RX) • DS1 ESF-FDL TX line and payload loopbacks • DS1 SF (D4) “in-band” TX loopbacks • AT&T TR 54016 ESF DS1 TX line and payload loopbacks Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-29 Chapter 3 Electrical Cards 3.11.7 DS3XM-12 Slots and Connectors Table 3-15 DS3XM-12 Features Feature Description DS1 Auto-Frame Detection DS1 frame autodetection and autoprovisioning Manual DS1 frame provisioning Works in conjunction with the DS1 autoframe detection and gives you override capability Manual DS3 frame provisioning Legacy feature (C-Bit and M23 frame formats are supported) J1 Legacy feature (extended to 6 additional ports) J2 336 J2 strings are supported Portless Supports DS3 data from the backplane in addition to the DS3 data from the line interface unit Diagnostics Power-up diagnostics on working and protect cards Testing Connectivity, error rate, and error count of the traffic running on an Electrical IO card ports can be tested by using BERT. For more information on BERT, see 3.2 Bit Error Rate Testing, page 3-4. 3.11.7 DS3XM-12 Slots and Connectors The DS3XM-12 card can be used with BNC, SMB, SCSI (UBIC), or MiniBNC EIA connectors. The card can be installed in Slots 1 to 6 or 12 to 17. Each DS3XM-12 port features DSX-level outputs supporting distances up to 137 meters (450 feet) depending on facility conditions. 3.11.8 DS3XM-12 Faceplate and Block Diagram Figure 3-12 shows the DS3XM-12 faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 3-30 78-18106-01 Chapter 3 Electrical Cards 3.11.9 DS3XM-12 Card-Level Indicators Figure 3-12 DS3XM-12 Faceplate and Block Diagram DS3XM 12 FAIL ACT/STBY SF Main & Protect SCL Bus’s VT1.5 Mapped STS-1's (Both Modes) MAIN IBPIA ASIC 12 DS3 Transformers Ports & Protection Mux/Relays 12 Port DS3 LIU 4x DS3/VT1.5 Framer/ Mapper STS-24 Mapper FPGA PROTECT IBPIA ASIC B a c k p l a n e 115956 DS3 Mapped STS’1s (Portless Mode) Processor 3.11.9 DS3XM-12 Card-Level Indicators Table 3-16 describes the three card-level LEDs on the DS3XM-12 card faceplate. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 3-31 Chapter 3 Electrical Cards 3.11.10 DS3XM-12 Port-Level Indicators Table 3-16 DS3XM-12 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card processor is not ready. It is steady while the self-test runs, and blinks during provisioning. Replace the card if the red FAIL LED persists. ACT/STBY LED Green (Active) When the ACT/STBY LED is green, the DS3XM-12 card is operational and ready to carry traffic. When the ACT/STBY LED is amber, the DS3XM-12 card is operational and in standby in a 1:1 protection group. Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BER on one or more card ports. 3.11.10 DS3XM-12 Port-Level Indicators You can find the status of the twelve DS3XM-12 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to quickly view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Cisco ONS 15454 Reference Manual, R8.5.x 3-32 78-18106-01 CH A P T E R 4 Optical Cards Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This chapter describes the Cisco ONS 15454 optical card features and functions. It includes descriptions, hardware specifications, and block diagrams for each optical card. For installation and card turn-up procedures, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 4.1 Optical Card Overview, page 4-2 • 4.2 OC3 IR 4/STM1 SH 1310 Card, page 4-6 • 4.3 OC3 IR/STM1 SH 1310-8 Card, page 4-8 • 4.4 OC12 IR/STM4 SH 1310 Card, page 4-9 • 4.5 OC12 LR/STM4 LH 1310 Card, page 4-11 • 4.6 OC12 LR/STM4 LH 1550 Card, page 4-13 • 4.7 OC12 IR/STM4 SH 1310-4 Card, page 4-15 • 4.8 OC48 IR 1310 Card, page 4-17 • 4.9 OC48 LR 1550 Card, page 4-19 • 4.10 OC48 IR/STM16 SH AS 1310 Card, page 4-21 • 4.11 OC48 LR/STM16 LH AS 1550 Card, page 4-23 • 4.12 OC48 ELR/STM16 EH 100 GHz Cards, page 4-25 • 4.13 OC48 ELR 200 GHz Cards, page 4-27 • 4.14 OC192 SR/STM64 IO 1310 Card, page 4-29 • 4.15 OC192 IR/STM64 SH 1550 Card, page 4-31 • 4.16 OC192 LR/STM64 LH 1550 Card, page 4-33 • 4.17 OC192 LR/STM64 LH ITU 15xx.xx Card, page 4-38 • 4.18 15454_MRC-12 Multirate Card, page 4-41 • 4.19 MRC-2.5G-4 Multirate Card, page 4-46 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-1 Chapter 4 Optical Cards 4.1 Optical Card Overview • 4.20 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Cards, page 4-50 • 4.21 Optical Card SFPs and XFPs, page 4-52 4.1 Optical Card Overview Each card is marked with a symbol that corresponds to a slot (or slots) on the ONS 15454 shelf assembly. The cards are then installed into slots displaying the same symbols. See the “1.17 Cards and Slots” section on page 1-71 for a list of slots and symbols. 4.1.1 Card Summary Table 4-1 lists the Cisco ONS 15454 optical cards. Table 4-1 Optical Cards for the ONS 15454 Card Port Description For Additional Information... OC3 IR 4 SH 1310 The OC3 IR 4 SH 1310 card provides four intermediate- or short-range OC-3 ports and operates at 1310 nm. See the “4.2 OC3 IR 4/STM1 SH 1310 Card” section on page 4-6. Note The OC3 IR 4 SH 1310 and OC3 IR 4/STM1 SH 1310 cards are functionally the same. OC3 IR 4/ STM1 SH 1310 The OC3 IR 4/STM1 SH 1310 card provides four intermediate- or short-range OC-3 ports and operates at 1310 nm. See the “4.2 OC3 IR 4/STM1 SH 1310 Card” section on page 4-6. OC3 IR/ STM1 SH 1310-8 The OC3 IR/STM1 SH 1310-8 card provides eight intermediate- or short-range OC-3 ports and operates at 1310 nm. See the “4.3 OC3 IR/STM1 SH 1310-8 Card” section on page 4-8. OC12 IR 1310 The OC12 IR 1310 card provides one intermediate- or See the “4.4 OC12 IR/STM4 SH 1310 Card” short-range OC-12 port and operates at 1310 nm. section on page 4-9. Note The OC12 IR 1310 and OC12/STM4 SH 1310 cards are functionally the same. OC12 IR/STM4 SH The OC12 IR/STM4 SH 1310 card provides one 1310 intermediate- or short-range OC-12 port and operates at 1310 nm. OC12 LR 1310 The OC12 LR 1310 card provides one long-range OC-12 port and operates at 1310 nm. Note The OC12 LR 1310 and OC12 LR/STM4 LH 1310 cards are functionally the same. See the “4.4 OC12 IR/STM4 SH 1310 Card” section on page 4-9. See the “4.5 OC12 LR/STM4 LH 1310 Card” section on page 4-11. OC12 LR/STM4 LH 1310 The OC12 LR/STM4 LH 1310 card provides one long-range OC-12 port and operates at 1310 nm. See the “4.5 OC12 LR/STM4 LH 1310 Card” section on page 4-11. OC12 LR 1550 The OC12 LR 1550 card provides one long-range OC-12 port and operates at 1550 nm. See the “4.6 OC12 LR/STM4 LH 1550 Card” section on page 4-13. Note The OC12 LR 1550 and OC12 LR/STM4 LH 1550 cards are functionally the same. Cisco ONS 15454 Reference Manual, R8.5.x 4-2 78-18106-01 Chapter 4 Optical Cards 4.1.1 Card Summary Table 4-1 Optical Cards for the ONS 15454 (continued) Card Port Description For Additional Information... OC12 LR/STM4 LH 1550 The OC12 LR/STM4 LH 1550 card provides one long-range OC-12 port and operates at 1550 nm. See the “4.6 OC12 LR/STM4 LH 1550 Card” section on page 4-13. OC12 IR/STM4 SH The OC12 IR/STM4 SH 1310-4 card provides four 1310-4 intermediate- or short-range OC-12 ports and operates at 1310 nm. See the “4.7 OC12 IR/STM4 SH 1310-4 Card” section on page 4-15. OC48 IR 1310 The OC48 IR 1310 card provides one intermediate-range OC-48 port and operates at 1310 nm. See the “4.8 OC48 IR 1310 Card” section on page 4-17. OC48 LR 1550 The OC48 LR 1550 card provides one long-range OC-48 port and operates at 1550 nm. See the “4.9 OC48 LR 1550 Card” section on page 4-19. OC48 IR/STM16 SH AS 1310 The OC48 IR/STM16 SH AS 1310 card provides one intermediate- or short-range OC-48 port at 1310 nm. See the “4.10 OC48 IR/STM16 SH AS 1310 Card” section on page 4-21. OC48 LR/STM16 LH AS 1550 The OC48 LR/STM16 LH AS 1550 card provides one See the “4.11 OC48 long-range OC-48 port at 1550 nm. LR/STM16 LH AS 1550 Card” section on page 4-23. OC48 ELR/STM16 EH 100 GHz The OC48 ELR/STM16 EH 100 GHz card provides one long-range (enhanced) OC-48 port and operates in Slot 5, 6, 12, or 13. This card is available in 18 different wavelengths (9 in the blue band and 9 in the red band) in the 1550-nm range, every second wavelength in the ITU grid for 100-GHz spacing dense wavelength division multiplexing (DWDM). OC48 ELR 200 GHz The OC48 ELR 200 GHz card provides one long-range See the “4.13 OC48 ELR (enhanced) OC-48 port and operates in Slot 5, 6, 12, or 200 GHz Cards” section on 13. This card is available in 18 different wavelengths page 4-27. (9 in the blue band and 9 in the red band) in the 1550-nm range, every fourth wavelength in the ITU grid for 200-GHz spacing DWDM. See the “4.12 OC48 ELR/STM16 EH 100 GHz Cards” section on page 4-25. OC192 SR/STM64 The OC192 SR/STM64 IO 1310 card provides one IO 1310 intra-office-haul OC-192 port at 1310 nm. See the “4.14 OC192 SR/STM64 IO 1310 Card” section on page 4-29. OC192 IR/STM64 SH 1550 The OC192 IR/STM64 SH 1550 card provides one intermediate-range OC-192 port at 1550 nm. See the “4.15 OC192 IR/STM64 SH 1550 Card” section on page 4-31. OC192 LR/STM64 LH 1550 The OC192 LR/STM64 LH 1550 card provides one long-range OC-192 port at 1550 nm. See the “4.16 OC192 LR/STM64 LH 1550 Card” section on page 4-33. OC192 LR/ STM64 The OC192 LR/STM64 LH ITU 15xx.xx card provides See the “4.17 OC192 LH ITU 15xx.xx LR/STM64 LH ITU 15xx.xx one extended long-range OC-192 port. This card is available in multiple wavelengths in the 1550-nm range of the ITU grid for 100-GHz-spaced DWDM. Card” section on page 4-38. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-3 Chapter 4 Optical Cards 4.1.2 Card Compatibility Table 4-1 Optical Cards for the ONS 15454 (continued) Card Port Description For Additional Information... 15454_MRC-12 The 15454_MRC-12 card provides up to twelve OC-3 See the or OC-12 ports, or up to four OC-48 ports. The card “4.18 15454_MRC-12 operates in Slots 1 to 6 and 12 to 17. Multirate Card” section on page 4-41. MRC-2.5G-4 The MRC-2.5G-4 card provides up to four OC-3/STM-1 or OC-12/STM-4 ports, or one OC-48/STM-16 ports. The card operates in Slots 1 to 6 and 12 to 17. See the “4.19 MRC-2.5G-4 Multirate Card” section on page 4-46. OC192SR1/STM6 4IO Short Reach and OC192/STM64 Any Reach1 The OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach cards each provide a single OC-192/STM-64 interface capable of operating with SR-1, IR-2, and LR-2 XFP modules (depending on the card) at 1310 nm and 1550 nm. The cards operate in Slot 5, 6, 12, or 13 with the XC10G and XC-VXC-10G cards. See the “4.20 OC192SR1/STM64I O Short Reach and OC192/STM64 Any Reach Cards” section on page 4-50. 1. In the Cisco Transport Controller (CTC) GUI, these cards are known as OC192-XFP. Note The Cisco OC3 IR/STM1 SH, OC12 IR/STM4 SH, and OC48 IR/STM16 SH interface optics, all working at 1310 nm, are optimized for the most widely used SMF-28 fiber, available from many suppliers. Corning MetroCor fiber is optimized for optical interfaces that transmit at 1550 nm or in the C and L DWDM windows, and targets interfaces with higher dispersion tolerances than those found in OC3 IR/STM1 SH, OC12 IR/STM4 SH, and OC48 IR/STM16 SH interface optics. If you are using Corning MetroCor fiber, OC3 IR/STM1 SH, OC12 IR/STM4 SH, and OC48 IR/STM16 SH interface optics become dispersion limited before they become attenuation limited. In this case, consider using OC12 LR/STM4 LH and OC48 LR/STM16 LH cards instead of OC12 IR/STM4 SH and OC48 IR/STM16 SH cards. With all fiber types, network planners/engineers should review the relative fiber type and optics specifications to determine attenuation, dispersion, and other characteristics to ensure appropriate deployment. 4.1.2 Card Compatibility Table 4-2 lists the CTC software compatibility for each optical card. See Table 2-5 on page 2-4 for a list of cross-connect cards that are compatible with each optical card. Note “Yes” indicates that this card is fully or partially supported by the indicated software release. Refer to the individual card reference section for more information about software limitations for this card. Cisco ONS 15454 Reference Manual, R8.5.x 4-4 78-18106-01 Chapter 4 Optical Cards 4.1.2 Card Compatibility Table 4-2 Optical Card Software Release Compatibility Optical Card R3.3 R3.4 R4.0 R4.1 R4.51 R4.6 R4.71 R5.0 R6.0 R7.0 R7.2 R8.0 8.5 OC3 IR 4 1310 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC3 IR 4/STM1 SH 1310 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC3 IR /STM1 SH 1310-8 — Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC12 IR/STM4 SH 1310 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC12 IR 1310 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC12 LR 1310 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC12 LR 1550 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC12 LR/STM4 LH 1310 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC12 LR/STM4 LH 1550 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC12 IR/STM4 SH 1310-4 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC48 IR 1310 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC48 LR 1550 — Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes 2 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes 3 OC48 LR/STM16 LH AS 1550 Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC48 ELR/STM16 EH 100 GHz Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC48 ELR 200 GHz Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC192 SR/STM64 IO 1310 — — Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC192 IR/STM64 SH 1550 — — Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC192 LR/STM64 LH 1550 (15454-OC192LR1550) Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC192 LR/STM64 LH 1550 (15454-OC192-LR2) — — Yes Yes — Yes — Yes Yes Yes Yes Yes Yes OC192 LR/STM64 LH ITU 15xx.xx — — Yes Yes — Yes — Yes Yes Yes Yes Yes Yes 15454_MRC-12 — — — — — — — — Yes Yes Yes Yes Yes MRC-2.5G-4 — — — — — — — — — — — Yes Yes OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach4 — — — — — — — — Yes Yes Yes Yes Yes OC48 IR/STM16 SH AS 1310 1. DWDM-only release. 2. To enable OC-192 and OC-48 any-slot card operation, use the XC10G or XC-VXC-10G card, the TCC+/TCC2/TCC2P card, Software R3.1 or later, and the 15454-SA-ANSI or 154545-SA-HD shelf assembly. Note that the TCC+ card is not compatible with Software 4.5 or later. 3. To enable OC-192 and OC-48 any-slot card operation, use the XC10G or XC-VXC-10G card, the TCC+/TCC2/TCC2P card, Software R3.1 or later, and the 15454-SA-ANSI or 154545-SA-HD shelf assembly. Note that the TCC+ card is not compatible with Software 4.5 or later. 4. These cards are designated as OC192-XFP in CTC. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-5 Chapter 4 Optical Cards 4.2 OC3 IR 4/STM1 SH 1310 Card 4.2 OC3 IR 4/STM1 SH 1310 Card Note For hardware specifications, see the “A.6.1 OC3 IR 4/STM1 SH 1310 Card Specifications” section on page A-28. See Table 4-2 on page 4-5 for optical card compatibility. The OC3 IR 4/STM1 SH 1310 card provides four intermediate or short range SONET/SDH OC-3 ports compliant with ITU-T G.707, ITU-T G.957, and Telcordia GR-253-CORE. Each port operates at 155.52 Mbps over a single-mode fiber span. The card supports Virtual Tributary (VT), nonconcatenated (STS-1), or concatenated (STS-1 or STS-3c) payloads. Figure 4-1 shows the OC3 IR 4/STM1 SH 1310 faceplate and a block diagram of the card. Warning Note The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 The OC3 IR 4 SH 1310 and OC3 IR 4/STM1 SH 1310 cards are functionally the same. Figure 4-1 OC3 IR 4/STM1 SH 1310 Faceplate and Block Diagram OC3IR4 STM1SH 1310 FAIL ACT OC-3 STS-12 Optical Transceiver STS-3 termination/ framing Optical Transceiver STS-3 termination/ framing Rx Optical Transceiver STS-3 termination/ framing Tx 2 Optical Transceiver STS-3 termination/ framing SF Tx 1 STS-12/ STS-3 Mux/Demux BTC ASIC B a c k p l a n e Rx Tx 3 Flash RAM Rx Tx 4 uP bus uP 61352 Rx 33678 12931 Cisco ONS 15454 Reference Manual, R8.5.x 4-6 78-18106-01 Chapter 4 Optical Cards 4.2.1 OC3 IR 4/STM1 SH 1310 Card-Level Indicators You can install the OC3 IR 4/STM1 SH 1310 card in Slots 1 to 6 and 12 to 17. The card can be provisioned as part of a path protection or a linear add/drop multiplexer (ADM) configuration. Each interface features a 1310-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC connectors. The OC3 IR 4/STM1 SH 1310 card supports 1+1 unidirectional or bidirectional protection switching. You can provision protection on a per port basis. The OC3 IR 4/STM1 SH 1310 card detects loss of signal (LOS), loss of frame (LOF), loss of pointer (LOP), line-layer alarm indication signal (AIS-L), and line-layer remote defect indication (RDI-L) conditions. Refer to the Cisco ONS 15454 Troubleshooting Guide for a description of these conditions. The card also counts section and line bit interleaved parity (BIP) errors. To enable automatic protection switching (APS), the OC3 IR 4/STM1 SH 1310 card extracts the K1 and K2 bytes from the SONET overhead to perform appropriate protection switches. The data communication channel/general communication channel (DCC/GCC) bytes are forwarded to the TCC2/TCC2P card, which terminates the DCC/GCC. 4.2.1 OC3 IR 4/STM1 SH 1310 Card-Level Indicators Table 4-3 describes the three card-level LED indicators on the OC3 IR 4/STM1 SH 1310 card. Table 4-3 OC3 IR 4/STM1 SH 1310 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. Green ACT LED The green ACT LED indicates that the card is carrying traffic or is traffic-ready. Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L, or high bit error rate (BER) on one or more of the card’s ports. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected and the links are working, the light turns off. 4.2.2 OC3 IR 4/STM1 SH 1310 Port-Level Indicators Eight bicolor LEDs show the status per port. The LEDs are green if the port is available to carry traffic, is provisioned as in-service, and is part of a protection group, in the active mode. You can find the status of the four card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-7 Chapter 4 Optical Cards 4.3 OC3 IR/STM1 SH 1310-8 Card 4.3 OC3 IR/STM1 SH 1310-8 Card Note For hardware specifications, see the “A.6.2 OC3 IR/STM1SH 1310-8 Card Specifications” section on page A-29. See Table 4-2 on page 4-5 for optical card compatibility. The OC3 IR/STM1 SH 1310-8 card provides eight intermediate or short range SONET/SDH OC-3 ports compliant with ITU-T G.707, ITU-T G.957, and Telcordia GR-253-CORE. Each port operates at 155.52 Mbps over a single-mode fiber span. The card supports VT, nonconcatenated (STS-1), or concatenated (STS-3C) payloads. Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Figure 4-2 shows the card faceplate and block diagram. Figure 4-2 OC3IR STM1SH 1310-8 OC3IR/STM1 SH 1310-8 Faceplate and Block Diagram STM-1 STM-1 FAIL ACT Optical Transceiver #1 BPIA RX Prot Optical Transceiver #2 BPIA RX Main SF STM-1 STM-1 STM-1 STM-1 STM-1 Optical Transceiver #4 Optical Transceiver #5 OCEAN ASIC B a c k p l a n e BPIA TX Prot BPIA TX Main Optical Transceiver #6 Optical Transceiver #7 Optical Transceiver #8 Flash RAM uP uP bus 134369 STM-1 Optical Transceiver #3 Cisco ONS 15454 Reference Manual, R8.5.x 4-8 78-18106-01 Chapter 4 Optical Cards 4.3.1 OC3 IR/STM1 SH 1310-8 Card-Level Indicators You can install the OC3 IR/STM1 SH 1310-8 card in Slots 1 to 4 and 14 to 17. The card can be provisioned as part of a path protection or an ADM configuration. Each interface features a 1310-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses LC connectors on the faceplate that are angled downward 12.5 degrees. The OC3 IR/STM1 SH 1310-8 card supports 1+1 unidirectional and bidirectional protection switching. You can provision protection on a per port basis. The OC3 IR/STM1 SH 1310-8 card detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. Refer to the Cisco ONS 15454 Troubleshooting Guide for a description of these conditions. The card also counts section and line BIP errors. To enable APS, the OC3 IR/STM1 SH 1310-8 card extracts the K1 and K2 bytes from the SONET overhead to perform appropriate protection switches. The OC3 IR/STM1 SH 1310-8 card supports full DCC/GCC connectivity for remote network management. 4.3.1 OC3 IR/STM1 SH 1310-8 Card-Level Indicators Table 4-4 describes the three card-level LEDs on the eight-port OC3 IR/STM1 SH 1310-8 card. Table 4-4 OC3IR/STM1 SH 1310-8 Card-Level Indicators Card-Level LED Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. Green ACT LED The green ACT LED indicates that the card is carrying traffic or is traffic-ready. Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L, or high BER on one or more of the card’s ports. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected and the links are working, the light turns off. 4.3.2 OC3 IR/STM1 SH 1310-8 Port-Level Indicators Eight bicolor LEDs show the status per port. The LEDs show green if the port is available to carry traffic, is provisioned as in-service, is part of a protection group, or is in the active mode. You can also find the status of the eight card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. 4.4 OC12 IR/STM4 SH 1310 Card Note For hardware specifications, see the “A.6.3 OC12 IR/STM4 SH 1310 Card Specifications” section on page A-30. See Table 4-2 on page 4-5 for optical card compatibility. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-9 Chapter 4 Optical Cards 4.4 OC12 IR/STM4 SH 1310 Card The OC12 IR/STM4 SH 1310 card provides one intermediate or short range SONET OC-12 port compliant with ITU-T G.707, ITU-T G.957, and Telcordia GR-253-CORE. The port operates at 622.08 Mbps over a single-mode fiber span. The card supports VT, nonconcatenated (STS-1), or concatenated (STS-3c, STS-6c, or STS-12c) payloads. Figure 4-3 shows the OC12 IR/STM4 SH 1310 faceplate and a block diagram of the card. Warning Note The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 The OC12 IR 1310 and OC12/STM4 SH 1310 cards are functionally the same. Figure 4-3 OC12 IR/STM4 SH 1310 Faceplate and Block Diagram OC12IR STM4SH 1310 FAIL ACT SF STS-12 Tx 1 Rx OC-12 Mux/ Demux Optical Transceiver Flash STS-12 BTC ASIC RAM Main SCI uP bus Protect SCI B a c k p l a n e 61353 uP 33678 12931 You can install the OC12 IR/STM4 SH 1310 card in Slots 1 to 6 and 12 to 17, and provision the card as a drop card or span card in a two-fiber BLSR, path protection, or ADM (linear) configuration. The OC12 IR/STM4 SH 1310 card interface features a 1310-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The OC12 IR/STM4 SH 1310 card uses SC optical connections and supports 1+1 unidirectional and bidirectional protection. Cisco ONS 15454 Reference Manual, R8.5.x 4-10 78-18106-01 Chapter 4 Optical Cards 4.4.1 OC12 IR/STM4 SH 1310 Card-Level Indicators The OC12 IR/STM4 SH 1310 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. Refer to the Cisco ONS 15454 Troubleshooting Guide for a description of these conditions. The card also counts section and line BIT errors. To enable APS, the OC12 IR/STM4 SH 1310 card extracts the K1 and K2 bytes from the SONET overhead to perform appropriate protection switches. The DCC/GCC bytes are forwarded to the TCC2/TCC2P card, which terminates the DCC/GCC. 4.4.1 OC12 IR/STM4 SH 1310 Card-Level Indicators Table 4-5 describes the three card-level LEDs on the OC12 IR/STM4 SH 1310 card. Table 4-5 OC12 IR/STM4 SH 1310 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. Green/Amber ACT LED The green ACT LED indicates that the card is operational and is carrying traffic or is traffic-ready. The amber ACT LED indicates that the card is part of an active ring switch (BLSR). Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L, or high BERs on one or more of the card’s ports. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected and the link is working, the light turns off. 4.4.2 OC12 IR/STM4 SH 1310 Port-Level Indicators You can find the status of the OC-12 IR/STM4 SH 1310 card port by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. 4.5 OC12 LR/STM4 LH 1310 Card Note For hardware specifications, see the “A.6.4 OC12 LR/STM4 LH 1310 Card Specifications” section on page A-31. See Table 4-2 on page 4-5 for optical card compatibility. The OC12 LR/STM4 LH 1310 card provides one long-range SONET OC-12 port per card compliant with ITU-T G.707, ITU-T G.957, and Telcordia GR-253-CORE. The port operates at 622.08 Mbps over a single-mode fiber span. The card supports VT, nonconcatenated (STS-1), or concatenated (STS-3c, STS-6c, or STS-12c) payloads. Figure 4-4 shows the OC12 LR/STM4 LH 1310 faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-11 Chapter 4 Optical Cards 4.5 OC12 LR/STM4 LH 1310 Card Warning Note The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 The OC12 LR 1310 and OC12 LR/STM4 LH 1310 cards are functionally the same. Figure 4-4 OC12 LR/STM4 LH 1310 Faceplate and Block Diagram OC12LR STM4LH 1310 FAIL ACT SF STS-12 Tx 1 Rx OC-12 Mux/ Demux Optical Transceiver Flash B a c k Main SCI p l a Protect SCI n e STS-12 BTC ASIC RAM uP bus 61354 uP 33678 12931 You can install the OC12 LR/STM4 LH 1310 card in Slots 1 to 6 and 12 to 17, and provision the card as a drop card or span card in a two-fiber BLSR, path protection, or ADM (linear) configuration. The OC12 LR/STM4 LH 1310 card interface features a 1310-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC optical connections and supports 1+1 unidirectional and bidirectional protection. The OC12 LR/STM4 LH 1310 card detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. Refer to the Cisco ONS 15454 Troubleshooting Guide for a description of these conditions. The card also counts section and line BIT errors. To enable APS, the OC12 LR/STM4 LH 1310 card extracts the K1 and K2 bytes from the SONET overhead to perform appropriate protection switches. The DCC/GCC bytes are forwarded to the TCC2/TCC2P card, which terminates the DCC/GCC. Cisco ONS 15454 Reference Manual, R8.5.x 4-12 78-18106-01 Chapter 4 Optical Cards 4.5.1 OC12 LR/STM4 LH 1310 Card-Level Indicators 4.5.1 OC12 LR/STM4 LH 1310 Card-Level Indicators Table 4-6 describes the three card-level LEDs on the OC12 LR/STM4 LH 1310 card. Table 4-6 OC12 LR/STM4 LH 1310 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. Replace the card if the red FAIL LED persists. Green/Amber ACT LED The green ACT LED indicates that the card is operational and is carrying traffic or is traffic-ready. The amber ACT LED indicates that the card is part of an active ring switch (BLSR). Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L, or high BERs on the card’s port. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected, the light turns off. 4.5.2 OC12 LR/STM4 LH 1310 Port-Level Indicators You can find the status of the OC12 LR/STM4 LH 1310 card port by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to quickly view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 4.6 OC12 LR/STM4 LH 1550 Card Note For hardware specifications, see the “A.6.5 OC12 LR/STM4 LH 1550 Card Specifications” section on page A-32. See Table 4-2 on page 4-5 for optical card compatibility. The OC12 LR/STM4 LH 1550 card provides one long-range SONET/SDH OC-12 port compliant with ITU-T G.707, ITU-T G.957, and Telcordia GR-253-CORE. The port operates at 622.08 Mbps over a single-mode fiber span. The card supports VT, nonconcatenated (STS-1), or concatenated (STS-3c, STS-6c, or STS-12c) payloads. Figure 4-5 shows the OC12 LR/STM4 LH 1550 faceplate and a block diagram of the card. Warning Note The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 The OC12 LR 1550 and OC12 LR/STM4 LH 1550 cards are functionally the same. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-13 Chapter 4 Optical Cards 4.6.1 OC12 LR/STM4 LH 1550 Card-Level Indicators Figure 4-5 OC12 LR/STM4 LH 1550 Faceplate and Block Diagram OC12LR STM4LH 1550 FAIL ACT SF STS-12 Tx 1 Rx OC-12 Mux/ Demux Optical Transceiver Flash STS-12 BTC ASIC RAM Main SCI uP bus Protect SCI B a c k p l a n e 61355 uP 33678 12931 You can install the OC12 LR/STM4 LH 1550 card in Slots 1 to 4 and 14 to 17. The OC12 LR/STM4 LH 1550 can be provisioned as part of a two-fiber BLSR, path protection, or linear ADM. The OC12 LR/STM4 LH 1550 uses long-reach optics centered at 1550 nm and contains a transmit and receive connector (labeled) on the card faceplate. The OC12 LR/STM4 LH 1550 uses SC optical connections and supports 1+1 bidirectional or unidirectional protection switching. The OC12 LR/STM4 LH 1550 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIT errors. 4.6.1 OC12 LR/STM4 LH 1550 Card-Level Indicators Table 4-7 describes the three card-level LEDs on the OC12 LR/STM4 LH 1550 card. Cisco ONS 15454 Reference Manual, R8.5.x 4-14 78-18106-01 Chapter 4 Optical Cards 4.6.2 OC12 LR/STM4 LH 1550 Port-Level Indicators Table 4-7 OC12 LR/STM4 LH 1550 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. Replace the card if the red FAIL LED persists. Green/Amber ACT LED The green ACT LED indicates that the card is operational and ready to carry traffic. The amber ACT LED indicates that the card is part of an active ring switch (BLSR). Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L, or high BERs on the card’s port. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected, the light turns off. 4.6.2 OC12 LR/STM4 LH 1550 Port-Level Indicators You can find the status of the OC12 LR/STM4 LH 1550 card port by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 4.7 OC12 IR/STM4 SH 1310-4 Card Note For hardware specifications, see the “A.6.6 OC12 IR/STM4 SH 1310-4 Specifications” section on page A-33. See Table 4-2 on page 4-5 for optical card compatibility. The OC12 IR/STM4 SH 1310-4 card provides four intermediate or short range SONET/SDH OC-12/STM-4 ports compliant with the ITU-T G.707, ITU-T G.957, and Telcordia GR-253-CORE. Each port operates at 622.08 Mbps over a single-mode fiber span. The card supports VT, nonconcatenated (STS-1), or concatenated (STS-1, STS-3c, STS-6c, or STS-12c) payloads. Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Figure 4-6 shows the OC12 IR/STM4 SH 1310-4 faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-15 Chapter 4 Optical Cards 4.7 OC12 IR/STM4 SH 1310-4 Card Figure 4-6 OC12 IR/STM4 SH 1310-4 Faceplate and Block Diagram OC12IR STM4SH 1310-4 FAIL ACT OC-12 STM-4 STS-12 Optical Transceiver STS-12/STM-4 termination/ framing Optical Transceiver STS-12/STM-4 termination/ framing Rx Optical Transceiver STS-12/STM-4 termination/ framing Tx 2 Optical Transceiver STS-12/STM-4 termination/ framing SF Tx 1 ASIC B a c k p l a n e Rx Tx 3 Flash RAM Rx Tx 4 uP bus uP 78095 Rx 33678 12931 You can install the OC12 IR/STM4 SH 1310-4 card in Slots 1 to 4 and 14 to 17. Each interface features a 1310-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC connectors. The OC12 IR/STM4 SH 1310-4 card supports 1+1 unidirectional and bidirectional protection switching. You can provision protection on a per port basis. The OC12 IR/STM4 SH 1310-4 card detects LOS, LOF, LOP, MS-AIS, and MS-FERF conditions. Refer to the Cisco ONS 15454 Troubleshooting Guide for a description of these conditions. The card also counts section and line BIP errors. To enable BLSR, the OC12 IR/STM4 SH 1310-4 card extracts the K1 and K2 bytes from the SONET overhead and processes them to switch accordingly. The DCC/GCC bytes are forwarded to the TCC2/TCC2P card, which terminates the DCC/GCC. Note If you ever expect to upgrade an OC-12/STM-4 ring to a higher bit rate, you should not put an OC12 IR/STM4 SH 1310-4 card in that ring. The four-port card is not upgradable to a single-port card. The reason is that four different spans, possibly going to four different nodes, cannot be merged to a single span. Cisco ONS 15454 Reference Manual, R8.5.x 4-16 78-18106-01 Chapter 4 Optical Cards 4.7.1 OC12 IR/STM4 SH 1310-4 Card-Level Indicators 4.7.1 OC12 IR/STM4 SH 1310-4 Card-Level Indicators Table 4-8 describes the three card-level LEDs on the OC12 IR/STM4 SH 1310-4 card. Table 4-8 OC12 IR/STM4 SH 1310-4 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. Replace the card if the red FAIL LED persists. Green ACT LED The green ACT LED indicates that the card is carrying traffic or is traffic-ready. Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L, or high BER on one or more of the card’s ports. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected, the light turns off. 4.7.2 OC12 IR/STM4 SH 1310-4 Port-Level Indicators You can find the status of the four card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 4.8 OC48 IR 1310 Card Note For hardware specifications, see the “A.6.7 OC48 IR 1310 Card Specifications” section on page A-34. See Table 4-2 on page 4-5 for optical card compatibility. Note Any new features that are available as part of this software release are not enabled for this card. The OC48 IR 1310 card provides one intermediate-range, SONET OC-48 port per card, compliant with Telcordia GR-253-CORE. Each port operates at 2.49 Gbps over a single-mode fiber span. The card supports VT, nonconcatenated (STS-1), or concatenated (STS-3c, STS-6c, STS-12c, or STS-48c) payloads. Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Figure 4-7 shows the OC48 IR 1310 faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-17 Chapter 4 Optical Cards 4.8.1 OC48 IR 1310 Card-Level Indicators Figure 4-7 OC48 IR 1310 Faceplate and Block Diagram OC48 IR 1310 FAIL ACT SF Tx 1 OC-48 Rx Optical Transceiver Flash Mux/ Demux RAM B a c k Main SCI p l a Protect SCI n e STS-48 BTC ASIC uP bus 61356 uP 33678 12931 You can install the OC48 IR 1310 card in Slots 5, 6, 12, and 13, and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, path protection, or in an ADM (linear) configuration. The OC-48 port features a 1310-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The OC48 IR 1310 uses SC connectors. The card supports 1+1 unidirectional and bidirectional protection switching. The OC48 IR 1310 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIP errors. 4.8.1 OC48 IR 1310 Card-Level Indicators Table 4-9 describes the three card-level LEDs on the OC48 IR 1310 card. Cisco ONS 15454 Reference Manual, R8.5.x 4-18 78-18106-01 Chapter 4 Optical Cards 4.8.2 OC48 IR 1310 Port-Level Indicators Table 4-9 OC48 IR 1310 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. Replace the card if the red FAIL LED persists. Green/Amber ACT LED The green ACT LED indicates that the card is carrying traffic or is traffic-ready. The amber ACT LED indicates that the card is part of an active ring switch (BLSR). Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L, or high BERs on the card’s port. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected, the light turns off. 4.8.2 OC48 IR 1310 Port-Level Indicators You can find the status of the OC48 IR 1310 card port by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 4.9 OC48 LR 1550 Card Note For hardware specifications, see the “A.6.8 OC48 LR 1550 Card Specifications” section on page A-35. See Table 4-2 on page 4-5 for optical card compatibility. Note Any new features that are available as part of this software release are not enabled for this card. The OC48 LR 1550 card provides one long-range, SONET OC-48 port per card, compliant with Telcordia GR-253-CORE. Each port operates at 2.49 Gbps over a single-mode fiber span. The card supports VT, nonconcatenated (STS-1), or concatenated (STS-3c, STS-6c, STS-12c, or STS-48c) payloads. Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Figure 4-8 shows the OC48 LR 1550 faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-19 Chapter 4 Optical Cards 4.9.1 OC48 LR 1550 Card-Level Indicators Figure 4-8 OC48 LR 1550 Faceplate and Block Diagram OC48 LR 1550 FAIL ACT SF Tx 1 Rx OC-48 Optical Transceiver Flash Mux/ Demux RAM uP bus B a c k Main SCI p l a Protect SCI n e STS-48 BTC ASIC 61359 uP 33678 12931 You can install OC48 LR 1550 cards in Slots 5, 6, 12, and 13 and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, path protection, or ADM (linear) configuration. The OC48 LR 1550 port features a 1550-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC connectors, and it supports 1+1 unidirectional and bidirectional protection switching. The OC48 LR 1550 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIP errors. 4.9.1 OC48 LR 1550 Card-Level Indicators Table 4-10 describes the three card-level LEDs on the OC48 LR 1550 card. Cisco ONS 15454 Reference Manual, R8.5.x 4-20 78-18106-01 Chapter 4 Optical Cards 4.9.2 OC48 LR 1550 Port-Level Indicators Table 4-10 OC48 LR 1550 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. Replace the card if the red FAIL LED persists. Green/Amber ACT LED The green ACT LED indicates that the card is carrying traffic or is traffic-ready. The amber ACT LED indicates that the card is part of an active ring switch (BLSR). Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on the card’s port. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected, the light turns off. 4.9.2 OC48 LR 1550 Port-Level Indicators You can find the status of the OC48 LR 1550 card port by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 4.10 OC48 IR/STM16 SH AS 1310 Card Note For hardware specifications, see the “A.6.9 OC48 IR/STM16 SH AS 1310 Card Specifications” section on page A-35. See Table 4-2 on page 4-5 for optical card compatibility. The OC48 IR/STM16 SH AS 1310 card provides one intermediate-range SONET/SDH OC-48 port compliant with ITU-T G.707, ITU-T G.957, and Telcordia GR-253-CORE. The port operates at 2.49 Gbps over a single-mode fiber span. The card supports VT, nonconcatenated (STS-1), or concatenated (STS-3c, STS-6c, STS-12c, or STS-48c) payloads. Figure 4-9 shows the OC48 IR/STM16 SH AS 1310 faceplate and a block diagram of the card. Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-21 Chapter 4 Optical Cards 4.10.1 OC48 IR/STM16 SH AS 1310 Card-Level Indicators Figure 4-9 OC48 IR/STM16 SH AS 1310 Faceplate and Block Diagram OC48IR STM16SH AS 1310 FAIL ACT SF OC-48 TX Optical Transceiver Mux/ Demux RX Flash BTC ASIC RAM B a c k Main SCI p l a Protect SCI n e STS-48 1 uP bus 61357 uP You can install the OC48 IR/STM16 SH AS 1310 card in Slots 1 to 6 and 12 to 17 and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, path protection, or ADM (linear) configuration. The OC-48 port features a 1310-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The OC48 IR/STM16 SH AS 1310 uses SC connectors. The card supports 1+1 unidirectional and bidirectional protection switching. The OC48 IR/STM16 SH AS 1310 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIP errors. 4.10.1 OC48 IR/STM16 SH AS 1310 Card-Level Indicators Table 4-11 lists the three card-level LEDs on the OC48 IR/STM16 SH AS 1310 card. Cisco ONS 15454 Reference Manual, R8.5.x 4-22 78-18106-01 Chapter 4 Optical Cards 4.10.2 OC48 IR/STM16 SH AS 1310 Port-Level Indicators Table 4-11 OC48 IR/STM16 SH AS 1310 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. Replace the card if the red FAIL LED persists. Green/Amber ACT LED The green ACT LED indicates that the card is carrying traffic or is traffic-ready. The amber ACT LED indicates that the card is part of an active ring switch (BLSR). Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L, or high BERs on the card’s port. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected, the light turns off. 4.10.2 OC48 IR/STM16 SH AS 1310 Port-Level Indicators You can find the status of the OC48 IR/STM16 SH AS 1310 card port by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 4.11 OC48 LR/STM16 LH AS 1550 Card Note For hardware specifications, see the “A.6.10 OC48 LR/STM16 LH AS 1550 Card Specifications” section on page A-36. See Table 4-2 on page 4-5 for optical card compatibility. The OC48 LR/STM16 LH AS 1550 card provides one long-range SONET/SDH OC-48 port compliant with ITU-T G.707, ITU-T G.957, and Telcordia GR-253-CORE. Each port operates at 2.49 Gbps over a single-mode fiber span. The card supports VT, nonconcatenated (STS-1), or concatenated (STS-3c, STS-6c, STS-12c, or STS-48c) payloads. Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Figure 4-10 shows a block diagram and the faceplate of the OC48 LR/STM16 LH AS 1550 card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-23 Chapter 4 Optical Cards 4.11.1 OC48 LR/STM16 LH AS 1550 Card-Level Indicators Figure 4-10 OC48 LR/STM16 LH AS 1550 Faceplate and Block Diagram OC48LR STM16LH AS 1550 FAIL ACT SF OC-48 TX Optical Transceiver Mux/ Demux RX Flash BTC ASIC RAM B a c k Main SCI p l a Protect SCI n e STS-48 1 uP bus 61358 uP You can install OC48 LR/STM16 LH AS 1550 cards in Slots 1 to 6 and 12 to 17 and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, path protection, or ADM (linear) configuration. The OC48 LR/STM16 LH AS 1550 port features a 1550-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC connectors, and it supports 1+1 unidirectional and bidirectional protection switching. The OC48 LR/STM16 LH AS 1550 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIP errors. 4.11.1 OC48 LR/STM16 LH AS 1550 Card-Level Indicators Table 4-12 describes the three card-level LEDs on the OC48 LR/STM16 LH AS 1550 card. Cisco ONS 15454 Reference Manual, R8.5.x 4-24 78-18106-01 Chapter 4 Optical Cards 4.11.2 OC48 LR/STM16 LH AS 1550 Port-Level Indicators Table 4-12 OC48 LR/STM16 LH AS 1550 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. Replace the card if the red FAIL LED persists. Green/Amber ACT LED The green ACT LED indicates that the card is carrying traffic or is traffic-ready. The amber ACT LED indicates that the card is part of an active ring switch (BLSR). Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on the card’s port. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected, the light turns off. 4.11.2 OC48 LR/STM16 LH AS 1550 Port-Level Indicators You can find the status of the OC48 LR/STM16 LH AS 1550 card port by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 4.12 OC48 ELR/STM16 EH 100 GHz Cards Note For hardware specifications, see the “A.6.11 OC48 ELR/STM 16 EH 100 GHz Card Specifications” section on page A-37. See Table 4-2 on page 4-5 for optical card compatibility. Thirty-seven distinct OC48 ELR/STM16 EH 100 GHz cards provide the ONS 15454 DWDM channel plan. Each OC48 ELR/STM16 EH 100 GHz card has one SONET OC-48/SDH STM-16 port that complies with Telcordia GR-253-CORE, ITU-T G.692, and ITU-T G.958. The port operates at 2.49 Gbps over a single-mode fiber span. The card carries VT, concatenated (STS-1), and nonconcatenated (STS-1, STS-3c, STS-6c, STS-12c, or STS-48c) payloads. Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Figure 4-11 shows the OC48 ELR/STM16 EH 100 GHz faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-25 Chapter 4 Optical Cards 4.12 OC48 ELR/STM16 EH 100 GHz Cards Figure 4-11 OC48 ELR/STM16 EH 100 GHz Faceplate and Block Diagram OC48ELR STM16EH 100GHz 1560.61 FAIL ACT/STBY SF TX 1 RX OC-48 Optical Transceiver Flash Mux/ Demux RAM uP bus B a c k Main SCI p l a Protect SCI n e STS-48 BTC ASIC 61613 uP Nineteen of the cards operate in the blue band with spacing of 100 GHz on the ITU grid (1528.77 nm, 1530.33 nm, 1531.12 nm, 1531.90 nm, 1532.68 nm, 1533.47 nm, 1534.25 nm, 1535.04 nm, 1535.82 nm, 1536.61 nm, 1538.19 nm, 1538.98 nm, 1539.77 nm, 1540.56 nm, 1541.35 nm, 1542.14 nm, 1542.94 nm, 1543.73 nm, and 1544.53 nm). ITU spacing conforms to ITU-T G.692 and Telcordia GR-2918-CORE, Issue 2. The other eighteen cards operate in the red band with spacing of 100 GHz on the ITU grid (1546.12 nm, 1546.92 nm, 1547.72 nm, 1548.51 nm,1549.32 nm, 1550.12 nm, 1550.92 nm, 1551.72 nm, 1552.52 nm, 1554.13 nm, 1554.94 nm, 1555.75 nm, 1556.55 nm, 1557.36 nm, 1558.17 nm, 1558.98 nm, 1559.79 nm, and 1560.61 nm). These cards are also designed to interoperate with the Cisco ONS 15216 DWDM solution. You can install the OC48 ELR/STM16 EH 100 GHz cards in Slots 5, 6, 12, and 13 and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, path protection, or ADM (linear) configuration. Each OC48 ELR/STM16 EH 100 GHz card uses extended long-reach optics operating individually within the ITU-T 100-GHz grid. The OC-48 DWDM cards are intended to be used in applications with long unregenerated spans of up to 300 km (186 miles) (with mid-span amplification). These transmission distances are achieved through the use of inexpensive optical amplifiers (flat gain amplifiers) such as Cisco ONS 15216 erbium-doped fiber amplifiers (EDFAs). Maximum system reach in filterless applications is 26 dB without the use of optical amplifiers or regenerators. However, system reach also depends on the condition of the facilities, the number of splices and connectors, and other performance-affecting factors. When used in combination with Cisco ONS 15454 Reference Manual, R8.5.x 4-26 78-18106-01 Chapter 4 Optical Cards 4.12.1 OC48 ELR 100 GHz Card-Level Indicators ONS 15216 100-GHz filters, the link budget is reduced by the insertion loss of the filters plus an additional 2-dB power penalty. The wavelength stability of the OC48 ELR/STM16 EH 100 GHz cards is +/– 0.12 nm for the life of the product and over the full range of operating temperatures. Each interface contains a transmitter and receiver. The OC48 ELR/STM16 EH 100 GHz cards detect LOS, LOF, LOP, and AIS-L conditions. The cards also count section and line BIP errors. 4.12.1 OC48 ELR 100 GHz Card-Level Indicators Table 4-13 lists the three card-level LEDs on the OC48 ELR/STM16 EH 100 GHz cards. Table 4-13 OC48 ELR/STM16 EH 100 GHz Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. Replace the card if the red FAIL LED persists. Green/Amber ACT LED The green ACT LED indicates that the card is carrying traffic or is traffic-ready. The amber ACT LED indicates that the card is part of an active ring switch (BLSR). Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on the card’s port. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected, the light turns off. 4.12.2 OC48 ELR 100 GHz Port-Level Indicators You can find the status of the OC48 ELR/STM16 EH 100 GHz card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to quickly view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 4.13 OC48 ELR 200 GHz Cards Note For hardware specifications, see the “A.6.12 OC48 ELR 200 GHz Card Specifications” section on page A-38. See Table 4-2 on page 4-5 for optical card compatibility. Eighteen distinct OC48 ELR 200 GHz cards provide the ONS 15454 DWDM channel plan. Each OC48 ELR 200 GHz card provides one SONET OC-48 port that is compliant with Telcordia GR-253-CORE. The port operates at 2.49 Gbps over a single-mode fiber span. The card carries VT, concatenated (STS-1), or nonconcatenated (STS-3c, STS-6c, STS-12c, or STS-48c) payloads. Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Figure 4-12 shows the OC48 ELR 200 GHz faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-27 Chapter 4 Optical Cards 4.13 OC48 ELR 200 GHz Cards Figure 4-12 OC48 ELR 200 GHz Faceplate and Block Diagram OC48 ELR 1530.33 FAIL ACT/STBY SF TX 1 RX OC-48 Optical Transceiver Flash Mux/ Demux RAM uP bus B a c k Main SCI p l a Protect SCI n e STS-48 BTC ASIC 61360 uP Nine of the cards operate in the blue band with spacing of 200 GHz on the ITU grid (1530.33 nm, 1531.90 nm, 1533.47 nm, 1535.04 nm, 1536.61 nm, 1538.19 nm, 1539.77 nm, 1541.35 nm, and 1542.94 nm). The other nine cards operate in the red band with spacing of 200 GHz on the ITU grid (1547.72 nm, 1549.32 nm, 1550.92 nm, 1552.52 nm, 1554.13 nm, 1555.75 nm, 1557.36 nm, 1558.98 nm, and 1560.61 nm). These cards are also designed to interoperate with the Cisco ONS 15216 DWDM solution. You can install the OC48 ELR 200 GHz cards in Slots 5, 6, 12, and 13, and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, path protection, or ADM (linear) configuration. Each OC48 ELR 200 GHz card uses extended long-reach optics operating individually within the ITU-T 200-GHz grid. The OC48 ELR 200 GHz cards are intended to be used in applications with long unregenerated spans of up to 200 km (124 miles) (with mid-span amplification). These transmission distances are achieved through the use of inexpensive optical amplifiers (flat gain amplifiers) such as EDFAs. Using collocated amplification, distances up to 200 km (124 miles) can be achieved for a single channel, 160 km (99 miles) for 8 channels. Maximum system reach in filterless applications is 24 dB or approximately 80 km (50 miles) without the use of optical amplifiers or regenerators. However, system reach also depends on the condition of the facilities, the number of splices and connectors, and other performance-affecting factors. The OC48 ELR DWDM cards feature wavelength stability of +/–0.25 nm. Each interface contains a transmitter and receiver. Cisco ONS 15454 Reference Manual, R8.5.x 4-28 78-18106-01 Chapter 4 Optical Cards 4.13.1 OC48 ELR 200 GHz Card-Level Indicators The OC48 ELR 200 GHz cards support extended long-reach applications in conjunction with optical amplification. Using electro-absorption technology, the OC48 DWDM cards provide a solution at the lower extended long-reach distances. The OC48 ELR 200 GHz interface features a 1550-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC connectors and supports 1+1 unidirectional and bidirectional protection switching. The OC48 ELR 200 GHz cards detect LOS, LOF, LOP, AIS-L, and RDI-L conditions. The cards also count section and line BIP errors. To enable APS, the OC48 ELR 200 GHz cards extract the K1 and K2 bytes from the SONET overhead. The DCC bytes are forwarded to the TCC2/TCC2P card; the TCC2/TCC2P terminates the DCC/GCC. 4.13.1 OC48 ELR 200 GHz Card-Level Indicators Table 4-14 describes the three card-level LEDs on the OC48 ELR 200 GHz cards. Table 4-14 OC48 ELR 200 GHz Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. Replace the card if the red FAIL LED persists. Green/Amber ACT LED The green ACT LED indicates that the card is carrying traffic or is traffic-ready. The amber ACT LED indicates that the card is part of an active ring switch (BLSR). Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on the card’s port. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected, the light turns off. 4.13.2 OC48 ELR 200 GHz Port-Level Indicators You can find the status of the OC48 ELR 200 GHz card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to quickly view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. 4.14 OC192 SR/STM64 IO 1310 Card Note For hardware specifications, see the “A.6.13 OC192 SR/STM64 IO 1310 Card Specifications” section on page A-39. See Table 4-2 on page 4-5 for optical card compatibility. The OC192 SR/STM64 IO 1310 card provides one intra-office haul SONET/SDH OC-192 port in the 1310-nm wavelength range, compliant with ITU-T G.707, ITU-T G.691, ITU-T G.957, and Telcordia GR-253-CORE. The port operates at 9.95328 Gbps over unamplified distances up to 2 km (1.24 miles). The card supports VT, nonconcatenated (STS-1), or concatenated payloads. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-29 Chapter 4 Optical Cards 4.14.1 OC192 SR/STM64 IO 1310 Card-Level Indicators Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Figure 4-13 shows the OC192 SR/STM64 IO 1310 faceplate and block diagram. Figure 4-13 OC192 SR/STM64 IO 1310 Faceplate and Block Diagram OC192SR STM64IO 1310 STM-64/ OC-192 STM-64 / OC192 Optical transceiver Demux CDR Demux SCL FAIL BTC ASIC ACT SF STM-64 / OC192 Optical transceiver Mux CK Mpy STM-64/ OC-192 Mux SCL Tx 1 Rx SRAM Flash Processor 134367 ADC x 8 B a c k p l a n e You can install OC192 SR/STM64 IO 1310 cards in Slot 5, 6, 12, or 13. You can provision this card as part of a BLSR, a path protection, a linear configuration, or as a regenerator for longer span reaches. The OC192 SR/STM64 IO 1310 port features a 1310-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses a dual SC connector for optical cable termination. The card supports 1+1 unidirectional and bidirectional facility protection. It also supports 1:1 protection in four-fiber BLSR applications where both span switching and ring switching might occur. The OC192 SR/STM64 IO 1310 card detects SF, LOS, or LOF conditions on the optical facility. Refer to the Cisco ONS 15454 Troubleshooting Guide for a description of these conditions. The card also counts section and line BIP errors from B1 and B2 byte registers in the section and line overhead. 4.14.1 OC192 SR/STM64 IO 1310 Card-Level Indicators Table 4-15 describes the three card-level LEDs on the OC192 SR/STM64 IO 1310 card. Cisco ONS 15454 Reference Manual, R8.5.x 4-30 78-18106-01 Chapter 4 Optical Cards 4.14.2 OC192 SR/STM64 IO 1310 Port-Level Indicators Table 4-15 OC192 SR/STM64 IO 1310 Card-Level Indicators Card-Level LED Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. ACT/STBY LED If the ACT/STBY LED is green, the card is operational and ready to carry traffic. The amber ACT LED indicates that the card in standby mode or is part of an active ring switch (BLSR). Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on one or more of the card’s ports. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected and the link is working, the light turns off. 4.14.2 OC192 SR/STM64 IO 1310 Port-Level Indicators You can find the status of the OC192 SR/STM64 IO 1310 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. 4.15 OC192 IR/STM64 SH 1550 Card Note For hardware specifications, see the “A.6.14 OC192 IR/STM64 SH 1550 Card Specifications” section on page A-40. See Table 4-2 on page 4-5 for optical card compatibility. The OC192 IR/STM64 SH 1550 card provides one intermediate reach SONET/SDH OC-192 port in the 1550-nm wavelength range, compliant with ITU-T G.707,ITU-T G.691, ITU-T G.957, and Telcordia GR-253-CORE. The port operates at 9.95328 Gbps over unamplified distances up to 40 km (25 miles) with SMF-28 fiber limited by loss and/or dispersion. The card supports VT, nonconcatenated (STS-1), or concatenated payloads. Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Figure 4-14 shows the OC192 IR/STM64 SH 1550 faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-31 Chapter 4 Optical Cards 4.15.1 OC192 IR/STM64 SH 1550 Card-Level Indicators Figure 4-14 OC192 IR/STM64 SH 1550 Faceplate and Block Diagram OC192IR STM64SH 1550 STM-64/ OC-192 STM-64 / OC192 Optical transceiver Demux CDR Demux SCL FAIL ACT BTC ASIC SF STM-64 / OC192 Optical transceiver Mux CK Mpy Mux STM-64/ OC-192 SCL Tx 1 Rx SRAM Flash Processor 134368 ADC x 8 B a c k p l a n e Note You must use a 3 to 15 dB fiber attenuator (5 dB recommended) when working with the OC192 IR/STM64 SH 1550 card in a loopback. Do not use fiber loopbacks with the OC192 IR/STM64 SH 1550 card. Using fiber loopbacks can cause irreparable damage to the card. You can install OC192 IR/STM64 SH 1550 cards in Slot 5, 6, 12, or 13. You can provision this card as part of a BLSR, path protection, or linear configuration, or also as a regenerator for longer span reaches. The OC192 IR/STM64 SH 1550 port features a 1550-nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses a dual SC connector for optical cable termination. The card supports 1+1 unidirectional and bidirectional facility protection. It also supports 1:1 protection in four-fiber BLSR applications where both span switching and ring switching might occur. The OC192 IR/STM64 SH 1550 card detects SF, LOS, or LOF conditions on the optical facility. Refer to the Cisco ONS 15454 Troubleshooting Guide for a description of these conditions. The card also counts section and line BIP errors from B1 and B2 byte registers in the section and line overhead. 4.15.1 OC192 IR/STM64 SH 1550 Card-Level Indicators Table 4-16 describes the three card-level LEDs on the OC192 IR/STM64 SH 1550 card. Cisco ONS 15454 Reference Manual, R8.5.x 4-32 78-18106-01 Chapter 4 Optical Cards 4.15.2 OC192 IR/STM64 SH 1550 Port-Level Indicators Table 4-16 OC192 IR/STM64 SH 1550 Card-Level Indicators Card-Level LED Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. ACT/STBY LED If the ACT/STBY LED is green, the card is operational and ready to carry traffic. If the ACT/STBY LED is amber, the card is operational and in standby (protect) mode or is part of an active ring switch (BLSR). Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on one or more of the card’s ports. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected and the link is working, the light turns off. 4.15.2 OC192 IR/STM64 SH 1550 Port-Level Indicators You can find the status of the OC192 IR/STM64 SH 1550 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. 4.16 OC192 LR/STM64 LH 1550 Card Note For hardware specifications, see the “A.6.15 OC192 LR/STM64 LH 1550 Card Specifications” section on page A-41. See Table 4-2 on page 4-5 for optical card compatibility. Note Any new features that are available as part of this software release are not enabled for this card. The OC192 LR/STM64 LH 1550 card provides one long-range SONET/SDH OC-192 port compliant with ITU-T G.707, ITU-T G.691, ITU-T G.957, and Telcordia GR-253-CORE (except minimum and maximum transmit power, and minimum receive power). The card port operates at 9.95328 Gbps over unamplified distances up to 80 km (50 miles) with different types of fiber such as C-SMF or dispersion compensated fiber limited by loss and/or dispersion. The card supports VT, nonconcatenated (STS-1), or concatenated payloads. There are two versions of the OC192 LR/STM64 LH 1550. The earliest version has the product ID 15454-OC192LR1550, and the latest card’s product ID is 15454-OC192-LR2. These cards have slight specification differences that are noted throughout this description. Warning The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-33 Chapter 4 Optical Cards 4.16 OC192 LR/STM64 LH 1550 Card Note You can differentiate this OC-192/STM-64 card (15454-OC192-LR2, 15454E-L64.2-1) from the OC-192/STM-64 card with the product ID 15454-OC192LR1550 by looking at the faceplate. This card does not have a laser on/off switch. Figure 4-15 shows the OC192 LR/STM64 LH 1550 (15454-OC192LR1550) faceplate and a block diagram of the card. Figure 4-15 OC192 LR/STM64 LH 1550 (15454-OC192LR1550) Faceplate and Block Diagram OC192LR STM64LH 1550 FAIL ACT/STBY SF 0 OC-192 STS Optical transceiver Demux CDR Mux SCL BTC ASIC TX 1 OC-192 RX TX Optical transceiver Mux CK Mpy STS Mux SCL DANGER - INVISIBLE LASER RADIATION MAY BE EMITTED FROM THE END OF UNTERMINATED FIBER CABLE OR CONNECTOR. DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS. RX ! DAC x 8 ADC x 8 Dig Pol x 2 SRAM Flash B a c k p l a n e Processor MAX INPUT POWER LEVEL - 10dBm Class 1M (IEC) 61361 1 Class 1 (CDRH) Figure 4-16 shows an enlarged view of the faceplate warning for 15454-OC192-LR2. Cisco ONS 15454 Reference Manual, R8.5.x 4-34 78-18106-01 Chapter 4 Optical Cards 4.16 OC192 LR/STM64 LH 1550 Card Figure 4-16 Enlarged Section of the OC192 LR/STM64 LH 1550 (15454-OC192LR1550) Faceplate TX DANGER - INVISIBLE LASER RADIATION MAY BE EMITTED FROM THE END OF UNTERMINATED FIBER CABLE OR CONNECTOR. DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS. RX ! Class 1M (IEC) Class 1 (CDRH) 67465 MAX INPUT POWER LEVEL - 10dBm Figure 4-17 shows the OC192 LR/STM64 LH 1550 (15454-OC192-LR2) faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-35 Chapter 4 Optical Cards 4.16 OC192 LR/STM64 LH 1550 Card Figure 4-17 OC192 LR/STM64 LH 1550 (15454-OC192-LR2) Faceplate and Block Diagram 1550 FAIL ACT/STBY SF OC-192/STM-64 STS Optical transceiver Demux CDR Mux SCL BTC ASIC TX 1 OC-192/STM-64 RX Optical transceiver Mux CK Mpy STS Mux SCL RX ! B a c k p l a n e MAX INPUT POWER LEVEL -7 dBm SRAM Flash Processor 115222 ADC x 8 Figure 4-18 shows an enlarged view of the faceplate warning on 15454-OC192LR1550. Cisco ONS 15454 Reference Manual, R8.5.x 4-36 78-18106-01 Chapter 4 Optical Cards 4.16 OC192 LR/STM64 LH 1550 Card Figure 4-18 Enlarged Section of the OC192 LR/STM64 LH 1550 (15454-OC192-LR2) Faceplate 1550 FAIL ACT/STBY SF RX ! MAX INPUT POWER LEVEL -7 dBm TX 1 RX RX ! DATED JULY 26, 2001 LASER NOTICE No.50, AND 1040.11 EXCEPT FOR DEVIATIONS PURSUANT TO 115226 DATED JULY 26, 2001 LASER NOTICE No.50, AND 1040.11 EXCEPT FOR DEVIATIONS PURSUANT TO COMPLIES WITH 21 CFR 1040.10 COMPLIES WITH 21 CFR 1040.10 MAX INPUT POWER LEVEL -7 dBm Caution You must use a 19 to 24 dB (14 to 28 dB for 15454-OC192-LR2) (20 dB recommended) fiber attenuator when connecting a fiber loopback to an OC192 LR/STM64 LH 1550 card. Never connect a direct fiber loopback. Using fiber loopbacks causes irreparable damage to the card. A transmit-to-receive (Tx-to-Rx) connection that is not attenuated damages the receiver. You can install OC192 LR/STM64 LH 1550 cards in Slots 5, 6, 12, and 13 and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, path protection, ADM (linear) configuration, or as a regenerator for longer span reaches. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-37 Chapter 4 Optical Cards 4.16.1 OC192 LR/STM64 LH 1550 Card-Level Indicators The card port features a 1550-nm laser and contains a transmit and receive connector (labeled) on the card faceplate.The card uses a dual SC connector for optical cable termination. The card supports 1+1 unidirectional and bidirectional facility protection. It also supports 1:1 protection in four-fiber BLSR applications where both span switching and ring switching might occur. The OC192 LR/STM64 LH 1550 card detects SF, LOS, or LOF conditions on the optical facility. The card also counts section and line BIT errors from B1 and B2 byte registers in the section and line overhead. 4.16.1 OC192 LR/STM64 LH 1550 Card-Level Indicators Table 4-17 describes the three card-level LEDs on the OC192 LR/STM64 LH 1550 card. Table 4-17 OC192 LR/STM64 LH 1550 Card-Level Indicators Card-Level Indicators Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. Replace the card if the red FAIL LED persists. ACT/STBY LED If the ACT/STBY LED is green, the card is operational and ready to carry traffic. If the ACT/STBY LED is amber, the card is operational and in standby (protect) mode or is part of an active ring switch (BLSR). Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on the card’s port. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected, the light turns off. 4.16.2 OC192 LR/STM64 LH 1550 Port-Level Indicators You can find the status of the OC192 LR/STM64 LH 1550 card port by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of the port or card slot; the screen displays the number and severity of alarms for a given port or slot. Note The optical output power of the OC192 LR/STM64 LH 1550 (+4 dBm to +7 dBm) is 6 dB lower than in L-64.2b of the 10/2000 prepublished unedited version of ITU-T G.691 (+10 dBm to +13 dBm). However, the total attenuation range of the optical path, 22 to 16 dB, is maintained by the optical receiver sensitivity range of the OC192 LR/STM64 LH 1550 (–7 dBm to –24 dBm). This sensitivity range outperforms the specification in L-64.2b of the 10/2000 prepublished unedited version of ITU-T G.691. The resulting link budget of the card is 26 dBm. 4.17 OC192 LR/STM64 LH ITU 15xx.xx Card Note For hardware specifications, see the “A.6.16 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications” section on page A-42. See Table 4-2 on page 4-5 for optical card compatibility. Cisco ONS 15454 Reference Manual, R8.5.x 4-38 78-18106-01 Chapter 4 Optical Cards 4.17 OC192 LR/STM64 LH ITU 15xx.xx Card Sixteen distinct OC-192/STM-64 ITU 100 GHz DWDM cards comprise the ONS 15454 DWDM channel plan. Each OC192 LR/STM64 LH ITU 15xx.xx card provides one long-reach STM-64/OC-192 port per card, compliant with ITU-T G.707, ITU-T G.957, and Telcordia GR-253-CORE (except minimum and maximum transmit power, and minimum receive power). The port operates at 9.95328 Gbps over unamplified distances up to 60 km (37 miles) with different types of fiber such as C-SMF or dispersion compensated fiber limited by loss and/or dispersion. Warning Note The laser is on when the optical card is booted. The port does not have to be in service for the laser to be on. Statement 293 Longer distances are possible in an amplified system using dispersion compensation. The card supports VT, nonconcatenated (STS-1), or concatenated payloads. Figure 4-19 shows the OC192 LR/STM64 LH ITU 15xx.xx faceplate. Figure 4-19 OC192 LR/STM64 LH ITU 15xx.xx Faceplate OC192LR STM64LH ITU FAIL ACT SF Tx 1 Rx RX RX MAX INPUT POWER LEVEL -8 dBm 33678 12931 83646 MAX INPUT POWER LEVEL -8 dBm Figure 4-20 shows a block diagram of the OC192 LR/STM64 LH ITU 15xx.xx card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-39 Chapter 4 Optical Cards 4.17.1 OC192 LR/STM64 LH ITU 15xx.xx Card-Level Indicators Figure 4-20 OC192 LR/STM64 LH ITU 15xx.xx Block Diagram STM-64/ OC-192 STM-64 / OC192 Optical transceiver Demux CDR Demux SCL BTC ASIC STM-64 / OC192 Optical transceiver Mux CK Mpy SRAM Flash SCL B a c k p l a n e Processor 63121 ADC x 8 Mux STM-64/ OC-192 Note You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the OC192 LR/STM64 LH 15xx.xx card in a loopback. Do not use fiber loopbacks with the OC192 LR/STM64 LH 15xx.xx card. Using fiber loopbacks causes irreparable damage to this card. Eight of the cards operate in the blue band with a spacing of 100 GHz in the ITU grid (1534.25 nm, 1535.04 nm, 1535.82 nm, 1536.61 nm, 1538.19 nm, 1538.98 nm, 1539.77 nm, and 1540.56 nm). The other eight cards operate in the red band with a spacing of 100 GHz in the ITU grid (1550.12 nm, 1550.92 nm, 1551.72 nm, 1552.52 nm, 1554.13 nm, 1554.94 nm, 1555.75 nm, and 1556.55 nm). You can install OC192 LR/STM64 LH ITU 15xx.xx cards in Slot 5, 6, 12, or 13. You can provision this card as part of an BLSR, path protection, or linear configuration or also as a regenerator for longer span reaches. The OC192 LR/STM64 LH ITU 15xx.xx port features a laser on a specific wavelength in the 1550-nm range and contains a transmit and receive connector (labeled) on the card faceplate. The card uses a dual SC connector for optical cable termination. The card supports 1+1 unidirectional and bidirectional facility protection. It also supports 1:1 protection in four-fiber BLSR applications where both span switching and ring switching might occur. The OC192 LR/STM64 LH ITU 15xx.xx card detects SF, LOS, or LOF conditions on the optical facility. Refer to the Cisco ONS 15454 Troubleshooting Guide for a description of these conditions. The card also counts section and line BIP errors from B1 and B2 byte registers in the section and line overhead. 4.17.1 OC192 LR/STM64 LH ITU 15xx.xx Card-Level Indicators Table 4-18 describes the three card-level LEDs on the OC192 LR/STM64 LH ITU 15xx.xx card. Cisco ONS 15454 Reference Manual, R8.5.x 4-40 78-18106-01 Chapter 4 Optical Cards 4.17.2 OC192 LR/STM64 LH ITU 15xx.xx Port-Level Indicators Table 4-18 OC192 LR/STM64 LH ITU 15xx.xx Card-Level Indicators Card-Level LED Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. ACT/STBY LED If the ACT/STBY LED is green, the card is operational and ready to carry traffic. If the ACT/STBY LED is amber, the card is operational and in standby (protect) mode or is part of an active ring switch (BLSR). Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on one or more of the card’s ports. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected and the link is working, the light turns off. 4.17.2 OC192 LR/STM64 LH ITU 15xx.xx Port-Level Indicators You can find the status of the OC192 LR/STM64 LH ITU 15xx.xx card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. 4.18 15454_MRC-12 Multirate Card Note For hardware specifications, see the “A.6.17 15454_MRC-12 Card Specifications” section on page A-44. See Table 4-2 on page 4-5 for optical card compatibility. The 15454_MRC-12 multirate card provides up to twelve OC-3/STM-1 ports, twelve OC-12/STM-4 ports, or four OC-48/STM-16 ports using small form-factor pluggables (SFPs), in any combination of line rates. All ports are Telcordia GR-253 compliant. The SFP optics can use SR, IR, LR, coarse wavelength division multiplexing (CWDM), and DWDM SFPs to support unrepeated spans. See the “4.21 Optical Card SFPs and XFPs” section on page 4-52 for more information about SFPs. The ports operate at up to 2488.320 Mbps over a single-mode fiber. The 15454_MRC-12 card has twelve physical connector adapters with two fibers per connector adapter (Tx and Rx). The card supports VT payloads, STS-1 payloads, and concatenated payloads at STS-3c, STS-6c, STS-9c, STS-12c, STS-18c, STS-24c, STS-36c, or STS-48c signal levels. It is fully interoperable with the ONS 15454 G-Series Ethernet cards. The 15454_MRC-12 port contains a transmit and receive connector (labeled) on the card faceplate. The card supports 1+1 unidirectional and bidirectional facility protection. It also supports 1+1 protection in four-fiber BLSR applications where both span switching and ring switching might occur. You can provision this card as part of an BLSR, path protection, or 1+1 linear configuration. Note Longer distances are possible in an amplified system using dispersion compensation. Figure 4-21 shows the 15454_MRC-12 faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-41 Chapter 4 Optical Cards 4.18.1 Slot Compatibility by Cross-Connect Card 15454_MRC-12 Card Faceplate and Block Diagram OC-3/12/48 (STM-1/4/16) COMPLIES WITH 21 CFR 1040.10 AND 1040.11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE No. 50, DATED JULY 26, 2001 OC-3/12 (STM-1/4/) OC-3/12 (STM-1/4) OC-3/12/48 (STM-1/4/16) OC-3/12 (STM-1/4) OC-3/12 (STM-1/4) OC-3/12/48 (STM-1/4/16) OC-3/12 (STM-1/4) OC-3/12 (STM-1/4) OC-3/12/48 (STM-1/4/16) OC-3/12 (STM-1/4) OC-3/12 (STM-1/4) Main SCL Intfc. Port 1 SFP Optical XCVR Protect SCL Intfc. Port 2 SFP Optical XCVR Main iBPIA Port 3 SFP Optical XCVR Port 4 SFP Optical XCVR Protect iBPIA Port 5 SFP Optical XCVR Port 6 SFP Optical XCVR B a c k p l a n e Amazon ASIC Port 7 SFP Optical XCVR Port 8 SFP Optical XCVR Processor Port 9 SFP Optical XCVR Port 0 SFP Optical XCVR Port 11 SFP Optical XCVR Flash Port 12 SFP Optical XCVR Memory 131788 Figure 4-21 4.18.1 Slot Compatibility by Cross-Connect Card You can install 15454_MRC-12 cards in Slots 1 through 6 and 12 through 17 with an XCVT, XC10G, or XC-VXC-10G. Note The 15454_MRC-12 card supports an errorless software-initiated cross-connect card switch when used in a shelf equipped with XC-VXC-10G and TCC2/TCC2P cards. Cisco ONS 15454 Reference Manual, R8.5.x 4-42 78-18106-01 Chapter 4 Optical Cards 4.18.2 Ports and Line Rates The maximum bandwidth of the 15454_MRC-12 card is determined by the cross-connect card, as shown in Table 4-19. Table 4-19 Maximum Bandwidth by Shelf Slot for the 15454_MRC-12 in Different Cross-Connect Configurations XC Card Type Maximum Bandwidth in Slots 1 through 4 Maximum Bandwidth and 14 through 17 in Slots 5, 6, 12, or 13 XCVT OC-12 OC-48 XC10G/XC-VXC-10G OC-48 OC-192 4.18.2 Ports and Line Rates Each port on the 15454_MRC-12 card can be configured as OC-3/STM-1, OC-12/STM-4, or OC-48/STM-16, depending on the available bandwidth and existing provisioned ports. Based on the cross-connect card and slot limitations shown in Table 4-19, the following rules apply for various synchronous transport signal (STS) available bandwidths. (Table 4-20 shows the same information in tabular format.) • STS-12 – Port 1 is the only port that is usable as an OC-12. If Port 1 is used as an OC-12, all other ports are disabled. – Ports 1, 4, 7, and 10 are the only ports usable as OC-3. If any of these ports is used as an OC-3, Ports 2, 3, 5, 6, 8, 9, 11, and 12 are disabled. • STS-48 – Port 1 is the only port usable as an OC-48. If Port 1 is used as an OC-48, all other ports are disabled. – Ports 1, 4, 7, and 10 are the only ports usable as OC-12. – If Port 4 is used as an OC-12, Ports 2 and 3 are disabled. – If Port 7 is used as an OC-12, Ports 5, 6, and 8 are disabled. – If Port 10 is used as an OC-12, Ports 9, 11, and 12 are disabled. – Any port can be used as an OC-3 as long as all of the above rules are followed. • STS-192 – Ports 1, 4, 7, and 10 are the only ports usable as OC-48. – If Port 4 is used as an OC-48, Ports 2 and 3 are disabled. – If Port 7 is used as an OC-48, Ports 5, 6, and 8 are disabled. – If Port 10 is used as an OC-48, Ports 9, 11, and 12 are disabled. – If Port 4 is used as an OC-12, Ports 2 and 3 can be used as an OC-12 or OC-3. – If Port 7 is used as an OC-12, Ports 5, 6, and 8 can be used as an OC-12 or OC-3. – If Port 10 is as used as an OC-12, Ports 9, 11, and 12 can be used as an OC-12 or OC-3. – If Port 4 is used as an OC-3, Ports 2 and 3 can be used as an OC-3 or OC-12. – If Port 7 is used as an OC-3, Ports 5, 6, and 8 can be used as an OC-3 or OC-12. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-43 Chapter 4 Optical Cards 4.18.2 Ports and Line Rates – If Port 10 is used as an OC-3, Ports 9, 11, and 12 can be used as an OC-3 or OC-12. – Any port can be used as an OC-12 or OC-3, as long as all of the above rules are followed. Table 4-20 shows the 15454_MRC-12 port availability and line rate for each port, based on total available bandwidth. To use the table, go to the rows for the bandwidth that you have available, as determined in Table 4-19. Each row indicates what line rate can be provisioned for each port (identified in the MCR-12 Port Number row). The Ports Used column shows the total number of ports that can be used with each bandwidth scheme. Table 4-20 Line Rate Configurations Per 15454_MRC-12 Port, Based on Available Bandwidth MRC-12 Port Number 1 2 3 4 OC-3 OC-1 2 OC-4 8 OC-3 OC-1 2 OC-3 OC-1 2 STS-12 Available Bandwidth 12 — 3 STS-48 Available Bandwidth Permitted Rate(s) 5 6 7 OC-3 OC-3 OC-12 OC-1 OC-48 2 OC-3 OC-1 2 — — — — — 3 3 3 3 3 — 3 8 11 12 Ports Total Used STSs 9 10 OC-3 OC-3 OC-12 OC-1 OC-48 2 OC-3 OC-1 2 OC-3 OC-3 OC-12 OC-1 OC-48 2 OC-3 OC-1 2 — — — — — — — — — 1 12 — — 3 — — 3 — — 4 12 3 3 3 3 3 3 3 3 3 12 36 — 12 3 3 3 3 3 3 3 3 10 39 — — 12 — — 12 — 3 3 3 3 7 39 3 — — 12 — — 12 — — 12 — — 4 39 12 3 3 3 3 3 3 3 3 3 3 3 12 45 12 — — 12 3 3 3 3 3 3 3 3 10 48 12 — — 12 — — 12 — 3 3 3 3 7 48 12 — — 12 — — 12 — — 12 — — 4 48 12 3 3 3 — — 12 — 3 3 3 3 9 45 12 3 3 3 3 3 3 3 — 12 — — 9 45 3 3 3 3 3 3 3 3 — 12 — — 9 36 3 3 3 3 — — 12 — — 12 — — 6 36 48 — — — — — — — — — — — 1 48 48 3 3 — 12 12 12 12 3 3 3 3 11 114 Cisco ONS 15454 Reference Manual, R8.5.x 4-44 78-18106-01 Chapter 4 Optical Cards 4.18.3 15454_MRC-12 Card-Level Indicators Table 4-20 Line Rate Configurations Per 15454_MRC-12 Port, Based on Available Bandwidth (continued) MRC-12 Port Number 1 STS-192 Available Bandwidth (when installing additional SFPs from the top port to the bottom port)1 STS-192 Available Bandwidth (when installing additional SFPs from the bottom port to the top port)1 2 3 4 5 6 7 8 9 10 11 12 Ports Total Used STSs 48 3 3 3 3 3 3 3 3 3 3 3 12 81 48 12 12 12 3 3 3 3 3 3 3 3 12 108 48 12 12 12 12 12 12 12 3 3 3 3 12 144 48 12 12 12 12 12 12 12 12 12 12 12 12 180 48 3 3 3 12 12 12 12 12 12 12 12 12 153 48 3 3 3 3 3 3 3 12 12 12 12 12 117 48 — — 48 3 3 3 3 3 3 3 3 10 120 48 — — 48 12 12 12 12 3 3 3 3 10 156 48 — — 48 12 12 12 12 12 12 12 12 10 192 48 — — 48 — — 48 — 3 3 3 3 7 156 48 — — 48 — — 48 — 12 12 12 12 7 192 48 — — 48 — — 48 — — 48 — — 4 192 3 3 3 3 3 3 3 3 — 48 — — 9 72 3 3 3 3 12 12 12 12 — 48 — — 9 108 3 12 12 12 12 12 12 12 — 48 — — 9 135 12 12 12 12 12 12 12 12 — 48 — — 9 144 12 12 12 12 3 3 3 3 — 48 — — 9 108 12 3 3 3 3 3 3 3 — 48 — — 9 81 3 3 3 3 — — 48 — — 48 — — 6 108 3 12 12 12 — — 48 — — 48 — — 6 135 12 12 12 12 — — 48 — — 48 — — 6 144 12 3 3 3 — — 48 — — 48 — — 6 117 3 — — 48 — — 48 — — 48 — — 4 147 12 — — 48 — — 48 — — 48 — — 4 156 1. If the MRC-12 card is initially populated with OC-3/12 on all its 12 ports, you can later add OC-48 SFPs on that card from top port to bottom port or from bottom port to top port. The maximum available bandwidth usage is different for these two cases. 4.18.3 15454_MRC-12 Card-Level Indicators Table 4-21 describes the three card-level LEDs on the 15454_MRC-12 card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-45 Chapter 4 Optical Cards 4.18.4 15454_MRC-12 Port-Level Indicators Table 4-21 15454_MRC-12 Card-Level Indicators Card-Level LED Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. ACT/STBY LED If the ACT/STBY LED is green, the card is operational and ready to carry traffic. If the ACT/STBY LED is amber, the card is operational and in standby (protect) mode or is part of an active ring switch (BLSR). Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on one or more of the card’s ports. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected and the link is working, the light turns off. 4.18.4 15454_MRC-12 Port-Level Indicators Each port has an Rx indicator. The LED flashes green if the port is receiving a signal, and it flashes red if the port is not receiving a signal. You can also find the status of the 15454_MRC-12 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. 4.19 MRC-2.5G-4 Multirate Card Note For hardware specifications, see the “A.6.17 15454_MRC-12 Card Specifications” section on page A-44. See Table 4-2 on page 4-5 for optical card compatibility. The MRC-2.5G-4 multirate card provides up to four OC-3/STM-1 ports, four OC-12/STM-4 ports, or one OC-48/STM-16 ports using small form-factor pluggables (SFPs), in various combinations of line rates. All ports are Telcordia GR-253 compliant. The SFP optics can use SR, IR, LR, coarse wavelength division multiplexing (CWDM), and DWDM SFPs to support unrepeated spans. See the “4.21 Optical Card SFPs and XFPs” section on page 4-52 for more information about SFPs. The ports operate at up to 2488.320 Mbps over a single-mode fiber. The MRC-2.5G-4 card has four physical connector adapters with two fibers per connector adapter (Tx and Rx). The card supports VT payloads, STS-1 payloads, and concatenated payloads at STS-3c, STS-6c, STS-9c, STS-12c, STS-18c, STS-24c, STS-36c, or STS-48c signal levels. It is fully interoperable with the ONS 15454 G-Series Ethernet cards. Each MRC-2.5G-4 port contains a transmit and receive connector (labeled) on the card faceplate. The card supports 1+1 unidirectional and bidirectional facility protection. It also supports 1+1 protection in four-fiber BLSR applications where both span switching and ring switching might occur. You can provision this card as part of an BLSR, path protection, or 1+1 linear configuration. The MRC-2.5G-4 card also supports optimized 1+1 protection when used with OC-3 SFPs. Cisco ONS 15454 Reference Manual, R8.5.x 4-46 78-18106-01 Chapter 4 Optical Cards 4.19 MRC-2.5G-4 Multirate Card Note 1+1 protection must be configured between the same equipment type, using the same port number and line rate. Note Longer distances are possible in an amplified system using dispersion compensation. Figure 4-22 shows the MRC-2.5G-4 faceplate and block diagram. Figure 4-22 MRC-2.5G-4 Card Faceplate and Block Diagram Main SCL Intfc. Protect SCL Intfc. Main iBPIA 1 OC-3/12/48 (STM-1/4/16) 2 OC-3/12 (STM-1/4/) OC-3/12 (STM-1/4) 3 OC-3/12 (STM-1/4/16) Protect iBPIA Port 1 SFP Optical XCVR Port 2 SFP Optical XCVR B a c k p l a n e Amazon ASIC Port 3 SFP Optical XCVR Port 4 SFP Optical XCVR Processor 4 Memory 159815 Flash Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-47 Chapter 4 Optical Cards 4.19.1 Slot Compatibility by Cross-Connect Card 4.19.1 Slot Compatibility by Cross-Connect Card You can install MRC-2.5G-4 cards in Slots 1 through 6 and 12 through 17 with an XCVT, XC10G, or XC-VXC-10G. Note The MRC-2.5G-4 card supports an errorless software-initiated cross-connect card switch when used in a shelf equipped with XC-VXC-10G and TCC2/TCC2P cards. The maximum bandwidth of the MRC-2.5G-4 card is determined by the cross-connect card, as shown in Table 4-22. Table 4-22 Maximum Bandwidth by Shelf Slot for the MRC-2.5G-4 in Different Cross-Connect Configurations XC Card Type Maximum Bandwidth in Slots 1 through 4 Maximum Bandwidth and 14 through 17 in Slots 5, 6, 12, or 13 XCVT OC-12 OC-48 XC10G/XC-VXC-10G OC-48 OC-48 4.19.2 Ports and Line Rates Total MRC-2.5G-4 card bandwidth cannot exceed OC-48/STM-16, so there are some limitations on which SFP ports can be used as OC-3/STM-1, OC-12/STM-4, and OC-48/STM-16. The following rules apply for port bandwidth allocation: • STS-12 maximum backplane bandwidth – Port 1 is the only port that is usable as an OC-12/STM-4. If Port 1 is used as an OC-12/STM-4, all other ports are disabled. – Each of the four ports can be used as OC-3/STM-1. • STS-48 maximum backplane bandwidth – Port 1 is the only port that is usable as an OC-48/STM-16. If Port 1 is used as an OC-48/STM-16, all other ports are disabled. – Mixed OC-3/STM-1 and OC-12/STM-4 configurations are supported. All possible permutations are not covered in this reference section. Cisco ONS 15454 Reference Manual, R8.5.x 4-48 78-18106-01 Chapter 4 Optical Cards 4.19.3 MRC-2.5G-4 Card-Level Indicators Table 4-23 shows the 15454_MRC-4 port availability and line rate for each port, based on total available bandwidth. To use the table, go to the rows for the bandwidth that you have available, as determined in Table 4-22. Each row indicates what line rate can be provisioned for each port (identified in the MCR-4 Port Number row). The Ports Used column shows the total number of ports that can be used with each bandwidth scheme. Table 4-23 Line Rate Configurations Per 15454_MRC- 4 Port, Based on Available Bandwidth MRC-4 Port Number 1 2 3 4 Ports Used Total STSs Permitted Rate(s) OC-3 OC-12 OC-48 OC-3 OC-12 OC-3 OC-12 OC-3 OC-12 — — STS-12 Available Bandwidth 12 — — — 1 12 3 3 3 3 4 12 STS-48 Available Bandwidth 48 — — — 1 48 12/3 12/3 12/3 12/3 4 With the MRC-4 card, you can have a maximum of 16 combinations of STS-48 available bandwidths with the OC-12 and OC-3 port rates. 4.19.3 MRC-2.5G-4 Card-Level Indicators Table 4-21 describes the three card-level LEDs on the MRC-2.5G-4 card. Table 4-24 MRC-2.5G-4 Card-Level Indicators Card-Level LED Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. ACT/STBY LED If the ACT/STBY LED is green, the card is operational and ready to carry traffic. If the ACT/STBY LED is amber, the card is operational and in standby (protect) mode or is part of an active ring switch (BLSR). Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on one or more of the card’s ports. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected and the link is working, the light turns off. 4.19.4 MRC-2.5G-4 Port-Level Indicators Each port has an Rx indicator. The LED flashes green if the port is receiving a signal, and it flashes red if the port is not receiving a signal. You can also find the status of the MRC-2.5G-4 card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-49 Chapter 4 Optical Cards 4.20 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Cards 4.20 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Cards Note For hardware specifications, see the “A.6.19 OC192SR1/STM64IO Short Reach Card Specifications” section on page A-47 and the “A.6.20 OC192/STM64 Any Reach Card Specifications” section on page A-47. See Table 4-2 on page 4-5 for optical card compatibility. The OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach cards each provide a single OC-192/STM-64 interface, as follows: • OC192SR1/STM64IO Short Reach card (SR-1) • OC192/STM-64 Any Reach card (SR-1, IR-2, and LR-2) In CTC, these cards are referred to as “OC192-XFP” cards. The interface operates at 9.952 Gbps over single-mode fiber spans and can be provisioned for both concatenated and nonconcatenated payloads on a per STS-1/VC-4 basis. Specification references can be found for the OC-192/STM-64 interface in ITU-T G.691, ITU-T G.693, and ITU-T G.959.1, and Telcordia GR-253. The optical interface uses a 10-Gbps Form-factor Pluggable (XFP) optical transceiver that plugs into a receptacle on the front of the card. The OC192SR1/STM64IO Short Reach card is used only with an SR-1 XFP, while the OC192/STM-64 Any Reach card can be provisioned for use with an SR-1, IR-2, LR-2, or DWDM XFP module. The XFP SR, IR, and LR interfaces each provide one bidirectional OC192/STM64 interface compliant with the recommendations defined by ITU-T G.91. SR-1 is compliant with ITU-T I-64.1, IR-2 is compliant with ITU G.691 S-64.2b, and LR-2 is compliant with ITU G.959.1 P1L1-2D2. The cards are used only in Slots 5, 6, 12, and 13. and only with 10-Gbps cross-connect cards, such as the XC10G and XC-VXC-10G. Note The OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach cards support an errorless software-initiated cross-connect card switch when used in a shelf equipped with XC-VXC-10G and TCC2/TCC2P cards. Figure 4-23 shows the faceplates and block diagram for the two cards. Cisco ONS 15454 Reference Manual, R8.5.x 4-50 78-18106-01 Chapter 4 Optical Cards 4.20 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Cards Figure 4-23 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Card Faceplates and Block Diagram OC192 STM64 ANY REACH OC192SR1 STM64IO SHORT REACH XFP FAIL FAIL ACT/STBY ACT/STBY SF SF OC-192 Main IBPIA Transport OH Processor and Backplane I/F FLASH Protect IBPIA I2C Mux T x 1 1 R x R x DDR SDRAM Serial EEPROM uP ID 134347 T x B a c k p l a n e The cards’ spans depend on the XFP module that is used: • A card using the SR-1 XFP is intended to be used in applications requiring 10-Gbps transport with unregenerated spans of up to 2.0 km. • A card using the IR-2 XFP is intended to be used in applications requiring 10-Gbps transport with unregenerated spans of up to 40 km. • A card using the LR-2 XFP is intended to be used in applications requiring 10-Gbps transport with unregenerated spans of up to 80 km. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-51 Chapter 4 Optical Cards 4.20.1 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Card-Level Indicators 4.20.1 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Card-Level Indicators Table 4-25 describes the three card-level LEDs on the OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach cards. Table 4-25 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Card-Level Indicators Card-Level LED Description Red FAIL LED The red FAIL LED indicates that the card’s processor is not ready. This LED is on during reset. The FAIL LED flashes during the boot process. Replace the card if the red FAIL LED persists. ACT/STBY LED If the ACT/STBY LED is green, the card is operational and ready to carry traffic. If the ACT/STBY LED is amber, the card is operational and in standby (protect) mode or is part of an active ring switch (BLSR). Green (Active) Amber (Standby) Amber SF LED The amber SF LED indicates a signal failure or condition such as LOS, LOF, or high BERs on one or more of the card’s ports. The amber SF LED is also on if the transmit and receive fibers are incorrectly connected. If the fibers are properly connected and the link is working, the light turns off. 4.20.2 OC192SR1/STM64IO Short Reach and OC-192/STM-64 Any Reach Port-Level Indicators You can find the status of the OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach card ports by using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. 4.21 Optical Card SFPs and XFPs The ONS 15454 optical cards use industry-standard SFPs and XFP modular receptacles. Currently, the only optical cards that use SFPs and XFPs are the 15454_MRC-12, MRC-2.5G-4, OC192SR1/STM64IO Short Reach, and OC192/STM64 Any Reach cards. For all optical cards, the type of SFP or XFP plugged into the card is displayed in CTC and TL1. Cisco offers SFPs and XFPs as separate orderable products. 4.21.1 Compatibility by Card Table 4-26 lists Cisco ONS 15454 optical cards and their compatible SFPs and XFPs. Caution Only use SFPs and XFPs certified for use in Cisco Optical Networking Systems (ONSs). The qualified Cisco SFP and XFP pluggable module’s top assembly numbers (TANs) are provided in Table 4-26. Cisco ONS 15454 Reference Manual, R8.5.x 4-52 78-18106-01 Chapter 4 Optical Cards 4.21.1 Compatibility by Card Table 4-26 SFP and XFP Card Compatibility Compatible SFPs and XFPs (Cisco Product ID) Cisco Top Assembly Number (TAN) 15454_MRC-12 and MRC-2.5G-4 (ONS 15454 SONET/SDH) ONS-SC-2G-28.7=1 through ONS-SC-2G-60.6= ONS_SE-155-1470= through ONS-SE-155-1610= ONS-SE-622-1470= through ONS-SE-622-1610= ONS-SI-155-I1= ONS-SI-155-L1= ONS-SI-155-L2= ONS-SI-2G-S1= ONS-SI-2G-I1= ONS-SI-2G-L1= ONS-SI-2G-L2= ONS-SI-622-I1= ONS-SI-622-L1= ONS-SI-622-L2= ONS-SI-155-SR-MM= ONS-SI-622-SR-MM= ONS-SC-Z3-1470= ONS-SC-Z3-1490= ONS-SC-Z3-1510= ONS-SC-Z3-1530= ONS-SC-Z3-1550= ONS-SC-Z3-1570= ONS-SC-Z3-1590= ONS-SC-Z3-1610= ONS-SE-Z1= ONS-SC-155-EL= 10-2307-02, 10-2155-01 through 10-2186-01 10-1996-01 through 10-2003-01 10-2004-01 through 10-2011-01 10-1938-01 10-1957-01 10-1937-01 10-1992-01 10-1993-01 10-2102-01 10-1990-01 10-1956-01 10-1958-01 10-1936-01 10-2279-01 10-2280-01 10-2285-01 10-2286-01 10-2287-01 10-2288-01 10-2289-01 10-2290-01 10-2291-01 10-2292-01 10-1971-01 10-2302-01 OC192SR1/STM64IO Short Reach (ONS 15454 SONET/SDH)2 ONS-XC-10G-S1 10-2012-01 OC192/STM64 Any Reach (ONS 15454 SONET/SDH)1 ONS-XC-10G-S1 ONS-XC-10G-I2 ONS-XC-10G-L2 ONS-XC-10G-30.3= through ONS-XC-10G-61.4= 10-2012-01 10-2193-01 10-2194-01 10-2347-01 through 10-2309-01 Card 1. ONS-SC-2G-28.7, ONS-SC-2G-33.4, ONS-SC-2G-41.3, ONS-SC-2G-49.3, and ONS-SC-2G-57.3 are supported from Release 8.5 and later. 2. This card is designated as OC192-XFP in CTC SFPs that are LED based do not support the Optical power transmitted (OPT) and laser bias current (LBC) optical parameters. Table 4-27 lists the LED based SFPs. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-53 Chapter 4 Optical Cards 4.21.2 SFP Description Table 4-27 LED Based SFPs SFPs (Cisco Product ID) Cisco Top Assembly Number (TAN) ONS-SI-155-SR-MM SFP 10-2279-01 ONS-SI-622-SR-MM SFP 10-2280-01 ONS-SE-100-FX 10-2212-01 ONS-SI-100-FX 10-2350-01 4.21.2 SFP Description SFPs are integrated fiber optic transceivers that provide high-speed serial links from a port or slot to the network. Various latching mechanisms can be utilized on the modules. There is no correlation between the type of latch to the model type (such as SX or LX/LH) or technology type (such as Gigabit Ethernet). See the label on the SFP for technology type and model. Three latch types are available: mylar (Figure 4-24), actuator/button (Figure 4-25), and bail clasp (Figure 4-26). Mylar Tab SFP Figure 4-25 Actuator/Button SFP Figure 4-26 Bail Clasp SFP 63067 63066 63065 Figure 4-24 SFP dimensions are: Cisco ONS 15454 Reference Manual, R8.5.x 4-54 78-18106-01 Chapter 4 Optical Cards 4.21.3 XFP Description • Height 0.03 in. (8.5 mm) • Width 0.53 in. (13.4 mm) • Depth 2.22 in. (56.5 mm) SFP temperature ranges are: • COM—Commercial operating temperature range: 23 to 158 degrees Fahrenheit (–5 to 70 degrees Celsius) • EXT—Extended operating temperature range: 23 to185 degrees Fahrenheit (–5to 85 degrees Celsius) • IND—Industrial operating temperature range: –40 to 185 degrees Fahrenheit (–40 to 85 degrees Celsius) 4.21.3 XFP Description The 10-Gbps 1310-nm and 1550-nm XFP transceivers are integrated fiber optic transceivers that provide high-speed serial links at the following signaling rates: 9.95 Gbps, 10.31 Gbps, and 10.51 Gbps. The XFP integrates the receiver and transmit path. The transmit side recovers and retimes the 10-Gbps serial data and passes it to a laser driver. The laser driver biases and modulates a 1310-nm or 1550-nm distributed feedback (DFB) laser, enabling data transmission over single-mode fiber (SMF) through an LC connector. The receive side recovers and retimes the 10-Gbps optical data stream from a positive-intrinsic-negative (PIN) photodetector, transimpedance amplifier and passes it to an output driver. The XFP module uses the bail clasp latching mechanism, shown unlatched in Figure 4-27 and latched in Figure 4-28. See the label on the XFP for technology type and model. Bail Clasp XFP (Unlatched) Figure 4-28 Bail Clasp XFP (Latched) 115719 115720 Figure 4-27 XFP dimensions are: • Height 0.33 in. (8.5 mm) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 4-55 Chapter 4 Optical Cards 4.21.4 PPM Provisioning • Width 0.72 in. (18.3 mm) • Depth 3.1 in. (78 mm) XFP temperature ranges are: • COM—Commercial operating temperature range: 23 to 158 degrees Fahrenheit (–5 to 70 degrees Celsius) • EXT—Extended operating temperature range: 23 to185 degrees Fahrenheit (–5to 85 degrees Celsius) • IND—Industrial operating temperature range: –40 to 185 degrees Fahrenheit (–40 to 85 degrees Celsius) 4.21.4 PPM Provisioning SFPs and XFPs are known as pluggable-port modules (PPMs) in CTC. Multirate PPMs for the 15454_MRC-12 card can be provisioned for different line rates in CTC. For more information about provisioning PPMs, refer to the Cisco ONS 15454 Procedure Guide. Cisco ONS 15454 Reference Manual, R8.5.x 4-56 78-18106-01 CH A P T E R 5 Ethernet Cards Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. The Cisco ONS 15454 integrates Ethernet into a SONET platform through the use of Ethernet cards. This chapter describes the E-Series, G-Series, ML-Series, and CE-Series Ethernet cards. For installation and card turn-up procedures, refer to the Cisco ONS 15454 Procedure Guide. For ML-Series configuration information, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. Chapter topics include: • 5.1 Ethernet Card Overview, page 5-2 • 5.2 E100T-12 Card, page 5-4 • 5.3 E100T-G Card, page 5-6 • 5.4 E1000-2 Card, page 5-9 • 5.5 E1000-2-G Card, page 5-11 • 5.6 G1000-4 Card, page 5-14 • 5.7 G1K-4 Card, page 5-16 • 5.8 ML100T-12 Card, page 5-19 • 5.9 ML100X-8 Card, page 5-21 • 5.10 ML1000-2 Card, page 5-23 • 5.11 ML-MR-10 Card, page 5-25 • 5.12 CE-100T-8 Card, page 5-28 • 5.13 CE-1000-4 Card, page 5-30 • 5.14 CE-MR-10 Card, page 5-34 • 5.15 Ethernet Card GBICs and SFPs, page 5-36 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-1 Chapter 5 Ethernet Cards 5.1 Ethernet Card Overview 5.1 Ethernet Card Overview The card overview section summarizes the Ethernet card functions and provides the software compatibility for each card. Note Each card is marked with a symbol that corresponds to a slot (or slots) on the ONS 15454 shelf assembly. The cards are then installed into slots displaying the same symbols. Refer to the Cisco ONS 15454 Procedure Guide for a list of slots and symbols. 5.1.1 Ethernet Cards Table 5-1 lists the Cisco ONS 15454 Ethernet cards. Table 5-1 Ethernet Cards for the ONS 15454 Card Port Description For Additional Information... E100T-12 The E100T-12 card provides 12 switched, autosensing, See the “5.2 E100T-12 Card” 10/100BaseT Ethernet ports and is compatible with the section on page 5-4. XCVT card. E100T-G The E100T-G card provides 12 switched, autosensing, See the “5.3 E100T-G Card” 10/100BaseT Ethernet ports and is compatible with the section on page 5-6. XC10G and XC-VXC-10G cards. E1000-2 The E1000-2 card provides two IEEE-compliant, 1000-Mbps ports. Gigabit Interface Converters (GBICs) are separate. E1000-2-G See the “5.5 E1000-2-G Card” The E1000-2-G card provides two IEEE-compliant, 1000-Mbps ports. GBICs are separate. The E1000-2-G section on page 5-11. card is compatible with the XC10G and XC-VXC-10G cards. G1000-4 The G1000-4 card provides four IEEE-compliant, 1000-Mbps ports. GBICs are separate. The G1000-4 requires the XC10G card. G1K-4 See the “5.7 G1K-4 Card” The G1K-4 card provides four IEEE-compliant, 1000-Mbps ports. GBICs are separate. The G1K-4 card section on page 5-16. is functionally identical to the G1000-4 card, but can operate with XCVT, XC10G and XC-VXC-10G cross-connect cards. M100T-12 The ML100T-12 card provides 12 switched, autosensing, 10/100Base-T Ethernet ports. See the “5.8 ML100T-12 Card” section on page 5-19. M100X-8 The ML100X-8 card provides eight switched, 100BaseFX Ethernet ports. See the “5.9 ML100X-8 Card” section on page 5-21. M1000-2 The ML1000-2 card provides two IEEE-compliant, 1000-Mbps ports. Small Form-factor Pluggable (SFP) connectors are separate. See the “5.10 ML1000-2 Card” section on page 5-23. See the “5.4 E1000-2 Card” section on page 5-9. See the “5.6 G1000-4 Card” section on page 5-14 Cisco ONS 15454 Reference Manual, R8.5.x 5-2 78-18106-01 Chapter 5 Ethernet Cards 5.1.2 Card Compatibility Table 5-1 Ethernet Cards for the ONS 15454 (continued) Card Port Description For Additional Information... ML-MR-10 The ML-MR-10 card is a ten-port multilayer Ethernet card. The Ethernet ports support speeds of 10 Mbps, 100 Mbps, or 1000 Mbps through pluggable SFPs. See the “5.11 ML-MR-10 Card” section on page 5-25. CE-100T-8 The CE-100T-8 card provides eight IEEE-compliant, 10/100-Mbps ports. The CE-100T-8 can operate with the XC10G, XC-VXC-10G, or XCVT cross-connect cards. See the “5.12 CE-100T-8 Card” section on page 5-28. CE-MR-10 The CE-MR-10 card is a ten-port Ethernet card. The Ethernet ports support speeds of 10 Mbps, 100 Mbps, or 1000 Mbps through pluggable SFPs. See the “5.14 CE-MR-10 Card” section on page 5-34. CE-1000-4 The CE-1000-4 card provides four IEEE-compliant, 1000-Mbps ports. The CE-1000-4 card can operate with the XC10G, XC-VXC-10G, or XCVT cross-connect cards. See the “5.13 CE-1000-4 Card” section on page 5-30. CE-MR-10 The CE-MR-10 card provides ten IEEE-compliant, 10/100/1000-Mbps ports. The CE-MR-10 card can operate with the XC10G, XC-VXC-10G, or XCVT cross-connect cards. See the “5.14 CE-MR-10 Card” section on page 5-34. 5.1.2 Card Compatibility Table 5-2 lists the CTC software compatibility for each Ethernet card. Note Table 5-2 “Yes” indicates that this card is fully or partially supported by the indicated software release. Refer to the individual card reference section for more information about software limitations for this card. Ethernet Card Software Compatibility Ethernet Cards R2.2.2 R3.0.1 R3.1 R3.2 R3.3 R3.4 R4.0 R4.1 R4.5 R4.6 R4.7 R5.0 R6.0 R7.0 R7.2 R8.0 R8.5 E100T-12 Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes E1000-2 Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes E100T-G Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes E1000-2-G Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes G1000-4 — — — Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes G1K-4 — — — Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes ML100T-12 — — — — — — Yes Yes — Yes — Yes Yes Yes Yes Yes Yes ML100X-8 — — — — — — — — — — — — Yes Yes Yes Yes Yes ML1000-2 — — — — — — Yes Yes — Yes — Yes Yes Yes Yes Yes Yes ML-MR-10 — — — — — — — — — — — — — — — — Yes CE-100T-8 — — — — — — — — — — — Yes Yes Yes Yes Yes Yes Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-3 Chapter 5 Ethernet Cards 5.2 E100T-12 Card Table 5-2 Ethernet Card Software Compatibility (continued) Ethernet Cards R2.2.2 R3.0.1 R3.1 R3.2 R3.3 R3.4 R4.0 R4.1 R4.5 R4.6 R4.7 R5.0 R6.0 R7.0 R7.2 R8.0 R8.5 CE-1000-4 — — — — — — — — — — — — — Yes Yes Yes Yes CE-MR-10 — — — — — — — — — — — — — — — — Yes 5.2 E100T-12 Card Note For hardware specifications, see the “A.7.1 E100T-12 Card Specifications” section on page A-48. The ONS 15454 uses E100T-12 cards for Ethernet (10 Mbps) and Fast Ethernet (100 Mbps). Each card provides 12 switched, IEEE 802.3-compliant, 10/100BaseT Ethernet ports that can independently detect the speed of an attached device (autosense) and automatically connect at the appropriate speed. The ports autoconfigure to operate at either half or full duplex and determine whether to enable or disable flow control. You can also configure Ethernet ports manually. Figure 5-1 shows the faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 5-4 78-18106-01 Chapter 5 Ethernet Cards 5.2.1 Slot Compatibility Figure 5-1 E100T-12 Faceplate and Block Diagram E100T 12 FAIL ACT SF 1 Flash DRAM CPU 2 3 A/D Mux 4 5 6 10/100 PHYS Ethernet MACs/switch 7 FPGA BTC B a c k p l a n e 8 10 11 Buffer memory Control memory 61362 9 12 The E100T-12 Ethernet card provides high-throughput, low-latency packet switching of Ethernet traffic across a SONET network while providing a greater degree of reliability through SONET self-healing protection services. This Ethernet capability enables network operators to provide multiple 10/100-Mbps access drops for high-capacity customer LAN interconnects, Internet traffic, and cable modem traffic aggregation. It enables the efficient transport and co-existence of traditional time-division multiplexing (TDM) traffic with packet-switched data traffic. Each E100T-12 card supports standards-based, wire-speed, Layer 2 Ethernet switching between its Ethernet interfaces. The IEEE 802.1Q tag logically isolates traffic (typically subscribers). IEEE 802.1Q also supports multiple classes of service. 5.2.1 Slot Compatibility You can install the E100T-12 card in Slots 1 to 6 and 12 to 17. Multiple E-Series Ethernet cards installed in an ONS 15454 can act independently or as a single Ethernet switch. You can create logical SONET ports by provisioning synchronous transport signal (STS) channels to the packet switch entity within the ONS 15454. Logical ports can be created with a bandwidth granularity of STS-1. The E100T-12 supports STS-1, STS-3c, STS-6c, and STS-12c circuit sizes. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-5 Chapter 5 Ethernet Cards 5.2.2 E100T-12 Card-Level Indicators Note When making an STS-12c Ethernet circuit, the E-Series cards must be configured as single-card EtherSwitch. 5.2.2 E100T-12 Card-Level Indicators The E100T-12 card faceplate has two card-level LED indicators, described in Table 5-3. Table 5-3 E100T-12 Card-Level Indicators Card-Level Indicators Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the E100T-12 card. As part of the boot sequence, the FAIL LED is on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the E100T-12. If the ACT LED is green, it indicates that the E100T-12 card is active and the software is operational. SF LED Not used. 5.2.3 E100T-12 Port-Level Indicators The E100T-12 card has 12 pairs of LEDs (one pair for each port) to indicate port conditions. Table 5-4 lists the port-level indicators. You can find the status of the E100T-12 card port using the LCD on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Table 5-4 E100T-12 Port-Level Indicators LED State Description Amber The port is active (transmitting and receiving data). Solid green The link is established. Off The connection is inactive, or traffic is unidirectional. 5.2.4 Cross-Connect Compatibility The E100T-12 card is compatible with the XCVT card. Do not use the E100T-12 card with the XC10G and XC-VXC-10G cards. 5.3 E100T-G Card Note For hardware specifications, see the “A.7.2 E100T-G Card Specifications” section on page A-49. Cisco ONS 15454 Reference Manual, R8.5.x 5-6 78-18106-01 Chapter 5 Ethernet Cards 5.3 E100T-G Card The ONS 15454 uses E100T-G cards for Ethernet (10 Mbps) and Fast Ethernet (100 Mbps). Each card provides 12 switched, IEEE 802.3-compliant, 10/100BaseT Ethernet ports that can independently detect the speed of an attached device (autosense) and automatically connect at the appropriate speed. The ports autoconfigure to operate at either half or full duplex and determine whether to enable or disable flow control. You can also configure Ethernet ports manually. Figure 5-2 shows the faceplate and a block diagram of the card. Figure 5-2 E100T-G Faceplate and Block Diagram E100T-G FAIL ACT SF 1 Flash DRAM CPU 2 3 A/D Mux 4 5 6 10/100 PHYS Ethernet MACs/switch 7 FPGA BTC B a c k p l a n e 8 10 11 Buffer memory Control memory 61877 9 12 The E100T-G Ethernet card provides high-throughput, low-latency packet switching of Ethernet traffic across a SONET network while providing a greater degree of reliability through SONET self-healing protection services. This Ethernet capability enables network operators to provide multiple 10/100 Mbps access drops for high-capacity customer LAN interconnects, Internet traffic, and cable modem traffic aggregation. It enables the efficient transport and co-existence of traditional TDM traffic with packet-switched data traffic. Each E100T-G card supports standards-based, wire-speed, Layer 2 Ethernet switching between its Ethernet interfaces. The IEEE 802.1Q tag logically isolates traffic (typically subscribers). IEEE 802.1Q also supports multiple classes of service. Note When making an STS-12c Ethernet circuit, the E-Series cards must be configured as single-card EtherSwitch. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-7 Chapter 5 Ethernet Cards 5.3.1 Slot Compatibility 5.3.1 Slot Compatibility You can install the E100T-G card in Slots 1 to 6 and 12 to 17. Multiple E-Series Ethernet cards installed in an ONS 15454 can act independently or as a single Ethernet switch. You can create logical SONET ports by provisioning a number of STS channels to the packet switch entity within the ONS 15454. Logical ports can be created with a bandwidth granularity of STS-1. The ONS 15454 supports STS-1, STS-3c, STS-6c, or STS-12c circuit sizes. 5.3.2 E100T-G Card-Level Indicators The E100T-G card faceplate has two card-level LED indicators, described in Table 5-5. Table 5-5 E100T-G Card-Level Indicators Card-Level Indicators Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the E100T-G card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the E100T-G. If the ACT LED is green it indicates that the E100T-G card is active and the software is operational. SF LED Not used. 5.3.3 E100T-G Port-Level Indicators The E100T-G card has 12 pairs of LEDs (one pair for each port) to indicate port conditions (Table 5-6). You can find the status of the E100T-G card port using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Table 5-6 E100T-G Port-Level Indicators LED State Description Yellow (Active) Port is active (transmitting or receiving data). By default, indicates the transmitter is active but can be software controlled to indicate link status, duplex status, or receiver active. Solid Green (Link) Link is established. By default, indicates the link for this port is up, but can be software controlled to indicate duplex status, operating speed, or collision. 5.3.4 Cross-Connect Compatibility The E100T-G card is compatible with the XCVT, XC10G and XC-VXC-10G cards. Cisco ONS 15454 Reference Manual, R8.5.x 5-8 78-18106-01 Chapter 5 Ethernet Cards 5.4 E1000-2 Card 5.4 E1000-2 Card Note For hardware specifications, see the “A.7.3 E1000-2 Card Specifications” section on page A-49. The ONS 15454 uses E1000-2 cards for Gigabit Ethernet (1000 Mbps). The E1000-2 card provides two IEEE-compliant, 1000-Mbps ports for high-capacity customer LAN interconnections. Each port supports full-duplex operation. The E1000-2 card uses GBIC modular receptacles for the optical interfaces. For details, see the “5.15 Ethernet Card GBICs and SFPs” section on page 5-36. Figure 5-3 shows the card faceplate and a block diagram of the card. Figure 5-3 E1000-2 Faceplate and Block Diagram E1000 2 FAIL ACT SF Flash DRAM CPU RX 1 TX A/D Mux Gigabit Ethernet PHYS ACT/LINK RX 2 Ethernet MACs/switch Buffer memory Control memory FPGA BTC B a c k p l a n e 61363 ACT/LINK TX 33678 12931 The E1000-2 Gigabit Ethernet card provides high-throughput, low-latency packet switching of Ethernet traffic across a SONET network while providing a greater degree of reliability through SONET self-healing protection services. This enables network operators to provide multiple 1000-Mbps access drops for high-capacity customer LAN interconnects. It enables efficient transport and co-existence of traditional TDM traffic with packet-switched data traffic. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-9 Chapter 5 Ethernet Cards 5.4.1 Slot Compatibility Each E1000-2 card supports standards-based, Layer 2 Ethernet switching between its Ethernet interfaces and SONET interfaces on the ONS 15454. The IEEE 802.1Q VLAN tag logically isolates traffic (typically subscribers). Multiple E-Series Ethernet cards installed in an ONS 15454 can act together as a single switching entity or as independent single switches supporting a variety of SONET port configurations. You can create logical SONET ports by provisioning STS channels to the packet switch entity within the ONS 15454. Logical ports can be created with a bandwidth granularity of STS-1. The ONS 15454 supports STS-1, STS-3c, STS-6c, or STS-12c circuit sizes. Note When making an STS-12c circuit, the E-Series cards must be configured as single-card EtherSwitch. 5.4.1 Slot Compatibility You can install the E1000-2 card in Slots 1 to 6 and 12 to 17. The E1000-2 is compatible with the XCVT card but not the XC10G or and XC-VXC-10G cards. The E1000-2-G is compatible with the XC10G and XC-VXC-10G. 5.4.2 E1000-2 Card-Level Indicators The E1000-2 card faceplate has two card-level LED indicators, described in Table 5-7. Table 5-7 E1000-2 Card-Level Indicators Card-Level Indicators Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the E1000-2 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the E1000-2. When the ACT LED is green it indicates that the E1000-2 card is active and the software is operational. SF LED Not used. 5.4.3 E1000-2 Port-Level Indicators The E1000-2 card has one bicolor LED per port (Table 5-8). When the LED is solid green, it indicates that carrier is detected, meaning an active network cable is installed. When the LED is off, it indicates that an active network cable is not plugged into the port, or the card is carrying unidirectional traffic. When the LED flashes amber, it does so at a rate proportional to the level of traffic being received and transmitted over the port. Cisco ONS 15454 Reference Manual, R8.5.x 5-10 78-18106-01 Chapter 5 Ethernet Cards 5.4.4 Cross-Connect Compatibility Table 5-8 E1000-2 Port-Level Indicators LED State Description Amber The port is active (transmitting and receiving data). Solid green The link is established. Off The connection is inactive, or traffic is unidirectional. 5.4.4 Cross-Connect Compatibility The E1000-2 is compatible with XCVT cards. The XC10G and XC-VXC-10G cards require the E1000-2-G card. 5.5 E1000-2-G Card Note For hardware specifications, see the “A.7.4 E1000-2-G Card Specifications” section on page A-49. The ONS 15454 uses E1000-2-G cards for Gigabit Ethernet (1000 Mbps). The E1000-2-G card provides two IEEE-compliant, 1000-Mbps ports for high-capacity customer LAN interconnections. Each port supports full-duplex operation. The E1000-2-G card uses GBIC modular receptacles for the optical interfaces. For details, see the “5.15 Ethernet Card GBICs and SFPs” section on page 5-36. Figure 5-4 shows the card faceplate and a block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-11 Chapter 5 Ethernet Cards 5.5 E1000-2-G Card Figure 5-4 E1000-2-G Faceplate and Block Diagram E1000-2-G FAIL ACT SF Flash DRAM CPU RX 1 TX A/D Mux Gigabit Ethernet PHYS ACT/LINK Ethernet MACs/switch Buffer memory FPGA BTC B a c k p l a n e Control memory 61878 ACT/LINK RX 2 TX 33678 12931 The E1000-2-G Gigabit Ethernet card provides high-throughput, low-latency packet switching of Ethernet traffic across a SONET network while providing a greater degree of reliability through SONET self-healing protection services. This enables network operators to provide multiple 1000-Mbps access drops for high-capacity customer LAN interconnects. It enables efficient transport and co-existence of traditional TDM traffic with packet-switched data traffic. Each E1000-2-G card supports standards-based, Layer 2 Ethernet switching between its Ethernet interfaces and SONET interfaces on the ONS 15454. The IEEE 802.1Q VLAN tag logically isolates traffic (typically subscribers). Multiple E-Series Ethernet cards installed in an ONS 15454 can act together as a single switching entity or as independent single switches supporting a variety of SONET port configurations. Cisco ONS 15454 Reference Manual, R8.5.x 5-12 78-18106-01 Chapter 5 Ethernet Cards 5.5.1 E1000-2-G Card-Level Indicators You can create logical SONET ports by provisioning STS channels to the packet switch entity within the ONS 15454. Logical ports can be created with a bandwidth granularity of STS-1. The ONS 15454 supports STS-1, STS-3c, STS-6c, or STS-12c circuit sizes. Note When making an STS-12c Ethernet circuit, the E-Series cards must be configured as a single-card EtherSwitch. 5.5.1 E1000-2-G Card-Level Indicators The E1000-2-G card faceplate has two card-level LED indicators, described in Table 5-9. Table 5-9 E1000-2-G Card-Level Indicators Card-Level Indicators Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the E1000-2-G card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the E1000-2-G. If the ACT LED is green it indicates that the E1000-2-G card is active and the software is operational. SF LED The SF LED is not used in the current release. 5.5.2 E1000-2-G Port-Level Indicators The E1000-2-G card has one bicolor LED per port (Table 5-10). When the green LINK LED is on, carrier is detected, meaning an active network cable is installed. When the green LINK LED is off, an active network cable is not plugged into the port, or the card is carrying unidirectional traffic. The amber port ACT LED flashes at a rate proportional to the level of traffic being received and transmitted over the port. Table 5-10 E1000-2-G Port-Level Indicators LED State Description Amber The port is active (transmitting and receiving data). Solid green The link is established. Off The connection is inactive, or traffic is unidirectional. 5.5.3 Cross-Connect Compatibility The E1000-2-G is compatible with the XCVT, XC10G, and XC-VXC-10G cards. You can install the card in Slots 1 to 6 and 12 to 17. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-13 Chapter 5 Ethernet Cards 5.6 G1000-4 Card 5.6 G1000-4 Card The G1000-4 card requires the XC10G card. The ONS 15454 uses G1000-4 cards for Gigabit Ethernet (1000 Mbps). The G1000-4 card provides four ports of IEEE-compliant, 1000-Mbps interfaces. Each port supports full-duplex operation for a maximum bandwidth of OC-48 on each card. The G1000-4 card uses GBIC modular receptacles for the optical interfaces. For details, see the “5.15 Ethernet Card GBICs and SFPs” section on page 5-36. Note Any new features that are available as part of this software release are not enabled for this card. Figure 5-5 shows the card faceplate and the block diagram of the card. Figure 5-5 G1000-4 Faceplate and Block Diagram G1000 4 FAIL ACT RX Flash 1 DRAM CPU Decode PLD To FPGA, BTC, MACs TX ACT/LINK RX 2 GBICs TX Transceivers Ethernet MACs/switch Mux/ Demux FPGA Interface FPGA ACT/LINK RX POS Function BTC Protect/ Main Rx/Tx BPIAs B a c k p l a n e 3 TX Power ACT/LINK Clock Generation 67863 Buffer memory RX 4 TX ACT/LINK The G1000-4 Gigabit Ethernet card provides high-throughput, low latency transport of Ethernet encapsulated traffic (IP and other Layer 2 or Layer 3 protocols) across a SONET network. Carrier-class Ethernet transport is achieved by hitless (< 50 ms) performance in the event of any failures or protection Cisco ONS 15454 Reference Manual, R8.5.x 5-14 78-18106-01 Chapter 5 Ethernet Cards 5.6.1 STS-24c Restriction switches (such as 1+1 automatic protection switching [APS], path protection configuration, or bidirectional line switch ring [BLSR]). Full provisioning support is possible through Cisco Transport Controller (CTC), Transaction Language One (TL1), or Cisco Transport Manager (CTM). The circuit sizes supported are STS-1, STS-3c, STS-6c, STS-9c, STS-12c, STS-24c, and STS-48c. 5.6.1 STS-24c Restriction Due to hardware constraints, the card imposes an additional restriction on the combinations of circuits that can be dropped onto a G-Series card. These restrictions are transparently enforced by the ONS 15454, and you do not need to keep track of restricted circuit combinations. When a single STS-24c terminates on a card, the remaining circuits on that card can be another single STS-24c or any combination of circuits of STS-12c size or less that add up to no more than 12 STSs (that is a total of 36 STSs on the card). If STS-24c circuits are not being dropped on the card, the full 48 STSs bandwidth can be used with no restrictions (for example, using either a single STS-48c or 4 STS-12c circuits). Note The STS-24c restriction only applies when a single STS-24c circuit is dropped; therefore, you can easily minimize the impact of this restriction. Group the STS-24c circuits together on a card separate from circuits of other sizes. The grouped circuits can be dropped on other G-Series cards on the ONS 15454. 5.6.2 G1000-4 Card-Level Indicators The G1000-4 card faceplate has two card-level LED indicators, described in Table 5-11. Table 5-11 G1000-4 Card-Level Indicators Card-Level LEDs Description FAIL LED (red) The red FAIL LED indicates that the card’s processor is not ready or that a catastrophic software failure occurred on the G1000-4 card. As part of the boot sequence, the FAIL LED is turned on, and it turns off if the software is deemed operational. The red FAIL LED blinks when the card is loading software. ACT LED (green) A green ACT LED provides the operational status of the G1000-4. If the ACT LED is green, it indicates that the G1000-4 card is active and the software is operational. 5.6.3 G1000-4 Port-Level Indicators The G1000-4 card has one bicolor LED per port. Table 5-12 describes the status that each color represents. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-15 Chapter 5 Ethernet Cards 5.6.4 Slot Compatibility Table 5-12 G1000-4 Port-Level Indicators Port-Level LED Status Description Off No link exists to the Ethernet port. Steady amber A link exists to the Ethernet port, but traffic flow is inhibited. For example, an unconfigured circuit, an error on line, or a nonenabled port might inhibit traffic flow. Solid green A link exists to the Ethernet port, but no traffic is carried on the port. Flashing green A link exists to the Ethernet port, and traffic is carried on the port. The LED flash rate reflects the traffic rate for the port. 5.6.4 Slot Compatibility The G1000-4 card requires Cisco ONS 15454 Release 3.2 or later system software and the XC10G cross-connect card. You can install the card in Slots 1 to 6 and 12 to 17, for a total shelf capacity of 48 Gigabit Ethernet ports. The practical G1000-4 port per shelf limit is 40, because at least two slots are typically filled by OC-N trunk cards such as the OC-192. 5.7 G1K-4 Card Note For hardware specifications, see the “A.7.8 G1K-4 Card Specifications” section on page A-51. The G1K-4 card is the functional equivalent of the earlier G1000-4 card and provides four ports of IEEE-compliant, 1000-Mbps interfaces. Each interface supports full-duplex operation for a maximum bandwidth of 1 Gbps or 2 Gbps bidirectional per port, and 2.5 Gbps or 5 Gbps bidirectional per card. Each port autonegotiates for full duplex and IEEE 802.3x flow control. The G1K-4 card uses GBIC modular receptacles for the optical interfaces. For details, see the “5.15 Ethernet Card GBICs and SFPs” section on page 5-36. Figure 5-6 shows the card faceplate and the block diagram of the card. Cisco ONS 15454 Reference Manual, R8.5.x 5-16 78-18106-01 Chapter 5 Ethernet Cards 5.7.1 STS-24c Restriction Figure 5-6 G1K-4 Faceplate and Block Diagram G1K FAIL ACT RX Flash 1 DRAM CPU Decode PLD To FPGA, BTC, MACs TX ACT/LINK RX 2 Transceivers GBICs TX Ethernet MACs/switch Mux/ Demux FPGA Interface FPGA POS function BTC Protect/ Main Rx/Tx BPIAs ACT/LINK RX B a c k p l a n e 3 Power ACT/LINK Clock generation Buffer memory RX 4 83649 TX TX ACT/LINK The G1K-4 Gigabit Ethernet card provides high-throughput, low-latency transport of Ethernet encapsulated traffic (IP and other Layer 2 or Layer 3 protocols) across a SONET network while providing a greater degree of reliability through SONET self-healing protection services. Carrier-class Ethernet transport is achieved by hitless (< 50 ms) performance in the event of any failures or protection switches (such as 1+1 APS, path protection, BLSR, or optical equipment protection) and by full provisioning and manageability, as in SONET service. Full provisioning support is possible through CTC or CTM. Each G1K-4 card performs independently of the other cards in the same shelf. 5.7.1 STS-24c Restriction Due to hardware constraints, the card imposes an additional restriction on the combinations of circuits that can be dropped onto a G-Series card. These restrictions are transparently enforced by the ONS 15454, and you do not need to keep track of restricted circuit combinations. When a single STS-24c terminates on a card, the remaining circuits on that card can be another single STS-24c or any combination of circuits of STS-12c size or less that add up to no more than 12 STSs (that is a total of 36 STSs on the card). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-17 Chapter 5 Ethernet Cards 5.7.2 G1K-4 Compatibility If STS-24c circuits are not being dropped on the card, the full 48 STSs bandwidth can be used with no restrictions (for example, using either a single STS-48c or 4 STS-12c circuits). Note The STS-24c restriction only applies when a single STS-24c circuit is dropped; therefore, you can easily minimize the impact of this restriction. Group the STS-24c circuits together on a card separate from circuits of other sizes. The grouped circuits can be dropped on other G-Series cards on the ONS 15454. 5.7.2 G1K-4 Compatibility The G1K-4 card operates with the XCVT, XC10G or XC-VXC-10G cards. With the XC10G or XC-VXC-10G cards, you can install the G1K-4 card in Slots 1 to 6 and 12 to 17, for a total shelf capacity of 48 Gigabit Ethernet ports. (The practical limit is 40 ports because at least two slots are typically populated by optical cards such as OC-192). When used with the XCVT cards, the G1K-4 is limited to Slots 5, 6, 12, and 13. 5.7.3 G1K-4 Card-Level Indicators The G1K-4 card faceplate has two card-level LED indicators, described in Table 5-13. Table 5-13 G1K-4 Card-Level Indicators Card-Level LEDs Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the G1K-4 card. As part of the boot sequence, the FAIL LED is turned on, and it goes off when the software is deemed operational. The red FAIL LED blinks when the card is loading software. ACT LED (Green) The green ACT LED provides the operational status of the G1K-4. If the ACT LED is green, it indicates that the G1K-4 card is active and the software is operational. 5.7.4 G1K-4 Port-Level Indicators The G1K-4 card has four bicolor LEDs (one LED per port). Table 5-14 describes the status that each color represents. Table 5-14 G1K-4 Port-Level Indicators Port-Level LED Status Description Off No link exists to the Ethernet port. Steady amber A link exists to the Ethernet port, but traffic flow is inhibited. For example, a lack of circuit setup, an error on the line, or a nonenabled port might inhibit traffic flow. Cisco ONS 15454 Reference Manual, R8.5.x 5-18 78-18106-01 Chapter 5 Ethernet Cards 5.8 ML100T-12 Card Table 5-14 G1K-4 Port-Level Indicators (continued) Port-Level LED Status Description Solid green A link exists to the Ethernet port, but no traffic is carried on the port. Flashing green A link exists to the Ethernet port, and traffic is carried on the port. The LED flash rate reflects the traffic rate for the port. 5.8 ML100T-12 Card Note For hardware specifications, see the “A.7.9 ML100T-12 Card Specifications” section on page A-51. The ML100T-12 card provides 12 ports of IEEE 802.3-compliant, 10/100 interfaces. Each interface supports full-duplex operation for a maximum bandwidth of 200 Mbps per port and 2.488 Gbps per card. Each port independently detects the speed of an attached device (autosenses) and automatically connects at the appropriate speed. The ports autoconfigure to operate at either half or full duplex and can determine whether to enable or disable flow control. For ML-Series configuration information, see the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. Figure 5-7 shows the card faceplate and block diagram. Caution Shielded twisted-pair cabling should be used for inter-building applications. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-19 Chapter 5 Ethernet Cards 5.8.1 ML100T-12 Card-Level Indicators Figure 5-7 ML100T-12 Faceplate and Block Diagram ML100T 12 BPIA Main Rx ACT Packet Buffer 6MB FAIL 0 SMII Packet Buffer 6MB Packet Buffer 4MB BPIA Protect Rx RGGI RGGI 1 4 2 4xMag. 2 3 12 x RJ45 4 2 4 2 4xMag. Octal PHY 6 port 0 port port 1 2 port A DOS FPGA 2 BTC192 5 6 6 4 4xMag. 4 Octal PHY port 1 port port 3 0 port B SCL 7 8 BPIA Main Tx B a c k p l a n e 9 11 ch0-1 ch4-5 Result Mem 2MB Control Mem 2MB Processor Daughter Card 128MB SDRAM 16MB FLASH 8KB NVRAM BPIA Protect Tx 134621 Control Mem 2MB 10 The card features two virtual packet over SONET (POS) ports with a maximum combined bandwidth of STS-48. The ports function in a manner similar to OC-N card ports, and each port carries an STS circuit with a size of STS-1, STS-3c, STS-6c, STS-9c, STS-12c, or STS-24c. To configure an ML-Series card SONET STS circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide. The ML-Series POS ports supports virtual concatenation (VCAT) of SONET circuits and a software link capacity adjustment scheme (SW-LCAS). The ML-Series card supports a maximum of two VCAT groups with each group corresponding to one of the POS ports. Each VCAT group must be provisioned with two circuit members. An ML-Series card supports STS-1c-2v, STS-3c-2v and STS-12c-2v. To configure an ML-Series card SONET VCAT circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide. 5.8.1 ML100T-12 Card-Level Indicators The ML00T-12 card supports two card-level LED indicators. The card-level indicators are described in Table 5-15. Cisco ONS 15454 Reference Manual, R8.5.x 5-20 78-18106-01 Chapter 5 Ethernet Cards 5.8.2 ML100T-12 Port-Level Indicators Table 5-15 ML100T-12 Card-Level Indicators Card-Level LEDs Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the ML100T-12 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the ML100T-12. If the ACT LED is green, it indicates that the ML100T-12 card is active and the software is operational. 5.8.2 ML100T-12 Port-Level Indicators The ML100T-12 card provides a pair of LEDs for each Fast Ethernet port: an amber LED for activity (ACT) and a green LED for LINK. The port-level indicators are described in Table 5-16. Table 5-16 ML100T-12 Port-Level Indicators Port-Level Indicators Description ACT LED (Amber) A steady amber LED indicates a link is detected, but there is an issue inhibiting traffic. A blinking amber LED means traffic is flowing. LINK LED (Green) A steady green LED indicates that a link is detected, but there is no traffic. A blinking green LED flashes at a rate proportional to the level of traffic being received and transmitted over the port. Both ACT and LINK LED Unlit green and amber LEDs indicate no traffic. 5.8.3 Cross-Connect and Slot Compatibility The ML100T-12 card works in Slots 1 to 6 or 12 to 17 with the XC10G or XC-VXC-10G card. 5.9 ML100X-8 Card Note For hardware specifications, see the “A.7.11 ML100X-8 Card Specifications” section on page A-52. The ML100X-8 card provides eight ports with 100BaseFX interfaces. The FX interfaces support one of two connectors, an LX SFP or an FX SFP. The LX SFP is a 100 Mbps 802.3-compliant SFP that operates over a pair of single-mode optical fibers and includes LC connectors. The FX SFP is a 100 Mbps 802.3compliant SFP that operates over a pair of multimode optical fibers and includes LC connectors. For more information on SFPs, see the “5.15 Ethernet Card GBICs and SFPs” section on page 5-36. Each interface supports full-duplex operation for autonegotiation and a maximum bandwidth of 200 Mbps per port and 2.488 Gbps per card. For ML-Series configuration information, see the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. Figure 5-8 shows the card faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-21 Chapter 5 Ethernet Cards 5.9.1 ML100X-8 Card-Level Indicators Figure 5-8 ML100X-8 Faceplate and Block Diagram ML 100X8 FAIL ACT Tx 0 Rx Tx 2 Rx Tx 3 Rx SFP SFP SFP SFP SFP Tx 4 Rx Tx 5 Rx PHY Network Processor Unit SFP SFP SONET Framer B a c k p l a n e SFP Tx 6 Rx TCAM 131786 Tx 1 Rx Packet Memory Tx 7 Rx The card features two virtual packet over SONET (POS) ports with a maximum combined bandwidth of STS-48. The ports function in a manner similar to OC-N card ports, and each port carries an STS circuit with a size of STS-1, STS-3c, STS-6c, STS-9c, STS-12c, or STS-24c. To configure an ML-Series card SONET STS circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide. The ML-Series POS ports supports virtual concatenation (VCAT) of SONET circuits and a software link capacity adjustment scheme (SW-LCAS). The ML-Series cards support a maximum of two VCAT groups with each group corresponding to one of the POS ports. Each VCAT group must be provisioned with two circuit members. An ML-Series card supports STS-1c-2v, STS-3c-2v and STS-12c-2v. To configure an ML-Series-card SONET VCAT circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide. 5.9.1 ML100X-8 Card-Level Indicators The ML100X-8 card supports two card-level LED indicators. Table 5-17 describes the card-level indicators. Cisco ONS 15454 Reference Manual, R8.5.x 5-22 78-18106-01 Chapter 5 Ethernet Cards 5.9.2 ML100X-8 Port-Level Indicators Table 5-17 ML100X-8 Card-Level Indicators Card-Level LEDs Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the ML100-FX card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the ML100-FX. If the ACT LED is green, it indicates that the ML100-FX card is active and the software is operational. 5.9.2 ML100X-8 Port-Level Indicators The ML100X-8 card provides a pair of LEDs for each Fast Ethernet port: an amber LED for activity (ACT) and a green LED for LINK. Table 5-18 describes the port-level indicators. Table 5-18 ML100X-8 Port-Level Indicators Port-Level Indicators Description ACT LED (Amber) A steady amber LED indicates a link is detected, but there is an issue inhibiting traffic. A blinking amber LED means traffic is flowing. LINK LED (Green) A steady green LED indicates that a link is detected, but there is no traffic. A blinking green LED flashes at a rate proportional to the level of traffic being received and transmitted over the port. Both ACT and LINK LED Unlit green and amber LEDs indicate no traffic. 5.9.3 Cross-Connect and Slot Compatibility The ML100X-8 card operates in Slots 1 to 6 or 12 to 17 with the XC10G or XC-VXC-10G cards. 5.10 ML1000-2 Card Note For hardware specifications, see the “A.7.10 ML1000-2 Card Specifications” section on page A-52. The ML1000-2 card provides two ports of IEEE-compliant, 1000-Mbps interfaces. Each interface supports full-duplex operation for a maximum bandwidth of 2 Gbps per port and 4 Gbps per card. Each port autoconfigures for full duplex and IEEE 802.3x flow control. SFP modules are offered as separate orderable products for maximum customer flexibility. For details, see the “5.15 Ethernet Card GBICs and SFPs” section on page 5-36. Figure 5-9 shows the ML1000-2 card faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-23 Chapter 5 Ethernet Cards 5.10.1 ML1000-2 Card-Level Indicators Figure 5-9 ML1000-2 Faceplate and Block Diagram ML100T 12 BPIA Main Rx ACT Packet Buffer 512Kx96 FAIL 0 1 2 Packet Buffer 512Kx96 SSRAM 2x512Kx36 Panel Port 0 SFP GBIC Module GMII Serdes port 0 port RGGI port 3 1 BPIA Protect Rx port RGGI port 2 A 3 MAC 1 4 MAC 2 DOS FPGA BTC192 5 6 7 8 Panel Port 1 SFP GBIC Module GMII Serdes port 1 port RGGI port 0 2 port RGGI port 3 B BPIA Main Tx B a c k p l a n e 9 10 Control Mem 512Kx32 ch0-1 ch4-5 BPIA Protect Tx Control Mem 512Kx32 11 134622 Result Mem 512Kx32 Processor Daughter Card (FLASHs, SDRAMs) The card features two virtual packet over SONET (POS) ports with a maximum combined bandwidth of STS-48. The ports function in a manner similar to OC-N card ports, and each port carries an STS circuit with a size of STS-1, STS-3c, STS-6c, STS-9c, STS-12c, or STS-24c. To configure an ML-Series card SONET STS circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide. The ML-Series POS ports supports VCAT of SONET circuits and a software link capacity adjustment scheme (SW-LCAS). The ML-Series card supports a maximum of two VCAT groups with each group corresponding to one of the POS ports. Each VCAT group must be provisioned with two circuit members. An ML-Series card supports STS-1c-2v, STS-3c-2v and STS-12c-2v. To configure an ML-Series card SONET VCAT circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide. 5.10.1 ML1000-2 Card-Level Indicators The ML1000-2 card faceplate has two card-level LED indicators, described in Table 5-19. Cisco ONS 15454 Reference Manual, R8.5.x 5-24 78-18106-01 Chapter 5 Ethernet Cards 5.10.2 ML1000-2 Port-Level Indicators Table 5-19 ML1000-2 Card-Level Indicators Card-Level LEDs Description SF LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the ML1000-2 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the ML1000-2. When the ACT LED is green, it indicates that the ML1000-2 card is active and the software is operational. 5.10.2 ML1000-2 Port-Level Indicators The ML1000-2 card has three LEDs for each of the two Gigabit Ethernet ports, described in Table 5-20. Table 5-20 ML1000-2 Port-Level Indicators Port-Level Indicators Description ACT LED (Amber) A steady amber LED indicates a link is detected, but there is an issue inhibiting traffic. A blinking amber LED means traffic flowing. LINK LED (Green) A steady green LED indicates that a link is detected, but there is no traffic. A blinking green LED flashes at a rate proportional to the level of traffic being received and transmitted over the port. Both ACT and LINK LED Unlit green and amber LEDs indicate no traffic. 5.10.3 Cross-Connect and Slot Compatibility The ML1000-2 card is compatible in Slots 1 to 6 or 12 to 17 with the XC10G or XC-VXC-10G card. It is only compatible in Slots 5, 6, 12, or 13 with the XCVT card. 5.11 ML-MR-10 Card Note For hardware specifications, see the “A.7.12 ML-MR-10 Card Specifications” section on page A-52. The ML-MR-10 card is a ten-port multilayer Ethernet card. The Ethernet ports support speeds of 10 Mbps, 100 Mbps, or 1000 Mbps through pluggable SFPs. SFP modules are offered as separate orderable products for flexibility. For details, see the “5.15 Ethernet Card GBICs and SFPs” section on page 5-36. The ML-MR-10 card supports a resilient packet ring (RPR) interface. RPR uses two POS like interfaces to terminate the SONET circuits. The circuit sizes supported on the RPR interfaces are STS-12c, STS -24c, STS- 48c, and STS -96c. A maximum aggregate of OC-192 of bandwidth can terminate on a single card. The RPR interface on ML-MR-10 supports only framed generic framing procedure (GFP-F) encapsulation for SONET. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-25 Chapter 5 Ethernet Cards 5.11 ML-MR-10 Card To configure a ML-MR-10 card SONET STS circuit, refer to the “Create Circuits and Tunnels” chapter in the Cisco ONS 15454 Procedure Guide. Cisco IOS is used to provision the Layer 2 functions of the card. The ML-MR-10 card provides management for Layer 1 operations through CTC. You can use CTM for Layer 1 and Layer 2 monitoring and fault detection, and TL1 supports card inventory and equipment alarming. Figure 5-10 shows the ML-MR-10 card faceplate and block diagram. Figure 5-10 ML-MR-10 Faceplate and Block Diagram ML-MR 10 FAIL ACT/STBY SF 10/100/1000 SFPs CPU interface CPU SFP Ingress PPE+ RPR TX 1 RX TX SFP 2 RX TX 3 MEM TCAM SFP RX TX 4 RX MEM SFP Reassembly+ Statistics MEM TX 5 RX SFP Serdes TX 6 RX SFP TX 10x GE MAC 7 RX 8 SFP TX 9 RX SFP TX 10 RX SFP CONSOLE MEM TM+ Ingress PPE+ RPR MEM SDH Framer Backplane I/F Instruction+ Statistics CPU interface SFP 240352 TX RX TM+ Queues B a c k p l a n e The ML-MR-10 card supports 1:1 protection at the port level. It also supports 1:1 card protection with redundant cards installed. For more information on ML-MR-10 card protection, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. The ML-MR-10 card supports the Version Up feature, which allows a user to independently upgrade ML-MR-10 cards as part of an overall software upgrade process. With this feature enabled, the user first upgrades all the cards in the node that are not ML-MR-10 cards, then in a second pass updates the ML-MR-10 cards. For more information on the Version Up feature, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. Cisco ONS 15454 Reference Manual, R8.5.x 5-26 78-18106-01 Chapter 5 Ethernet Cards 5.11.1 ML-MR-10 Card-Level Indicators The ML-MR-10 card supports an Ethernet Virtual Connection (EVC), which is an instance of an association of two or more user network interfaces (UNI) for Ethernet services. For more information on EVC, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. 5.11.1 ML-MR-10 Card-Level Indicators The ML-MR-10 card faceplate has two card-level LED indicators, described in Table 5-25. Table 5-21 ML-MR-10 Card-Level Indicators Card-Level LEDs Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the ML-MR-10 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the ML-MR-10 card. When the ACT LED is green, it indicates that the ML-MR-10 card is active and the software is operational. 5.11.2 ML-MR-10 Port-Level Indicators The ML-MR-10 card provides a pair of LEDs for each Ethernet port: an amber LED for activity (ACT) and a green LED for link status (LINK). Table 5-26 describes the status that each color represents. Table 5-22 ML-MR-10 Port-Level Indicators Port-Level Indicators Description Off No link exists to the Ethernet port. Steady amber A link exists to the Ethernet port, but traffic flow is inhibited. For example, a lack of circuit setup, an error on the line, or a disabled port might inhibit traffic flow. Solid green A link exists to the Ethernet port, but no traffic is carried on the port. Flashing green A link exists to the Ethernet port, and traffic is carried on the port. The LED flash rate reflects the traffic rate for that port. 5.11.3 Cross-Connect and Slot Compatibility The ML-MR-10 card can be installed in Slots 1 to 6 and 12 to 17 when used with the XC10G and XC-VXC-10G cards. It is not compatible with the XCVT card. Caution Fan-tray assembly 15454-CC-FTA (ANSI shelf) must be installed in a shelf where an ML-MR-10 card is installed. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-27 Chapter 5 Ethernet Cards 5.12 CE-100T-8 Card 5.12 CE-100T-8 Card Note For hardware specifications, see the “A.7.6 CE-100T-8 Card Specifications” section on page A-50. The CE-100T-8 card provides eight RJ-45 10/100 Mbps Ethernet ports and an RJ-45 console port on the card faceplate. The CE-100T-8 card provides mapping of 10/100 Mbps Ethernet traffic into SONET STS-12 payloads, making use of low-order (VT1.5) virtual concatenation, high-order (STS-1) virtual concatenation, GFP, and point-to-point protocol/high-level data link control (PPP/HDLC) framing protocols. The CE-100T-8 card also supports the link capacity adjustment scheme (LCAS), which allows hitless dynamic adjustment of SONET link bandwidth. The CE-100T-8 card’s LCAS is hardware-based, but the CE-100T-8 also supports SW-LCAS. This makes it compatible with the ONS 15454 SDH ML-Series card, which supports only SW-LCAS and does not support the standard hardware-based LCAS. SW-LCAS is supported when a circuit from the CE-100T-8 terminates on the ONS 15454 SDH ML-Series card. The circuit types supported are: • HO-CCAT • LO-VCAT with no HW-LCAS • LO-VCAT with HW-LCAS • STS-1-2v SW-LCAS with ML only Each 10/100 Ethernet port can be mapped to a SONET channel in increments of VT1.5 or STS-1 granularity, allowing efficient transport of Ethernet and IP over the SONET infrastructure. Figure 5-11 shows the CE-100T-8 card faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 5-28 78-18106-01 Chapter 5 Ethernet Cards 5.12 CE-100T-8 Card Figure 5-11 CE-100T-8 Faceplate and Block Diagram CE100T 8 Packet Buffer 3x0.5MB FAIL ACT 4 SMII SDRAM ETS #1 STS3 4 SMII 2 3 4 8x 10/100BaseT RJ45 Packet Octal SMII Processor/ PHY 8 Switch Fabric STS3 Add_Bus qMDM FPGA STS12 BTC Drop_Bus STS3 5 4 SMII ETS #3 6 7 1 8 3 SMII Control Mem 1x2MB SMII SDRAM STS3 ETS #4 SDRAM SCC1 CONSOLE Option qMDM FPGA B a c k p l a n e Part of qMDM FPGA 60x CPU MII FCC3 nVRAM Flash 8MB SDRAM 128MB CPLD 134366 1 SDRAM ETS #2 The following paragraphs describe the general functions of the CE-100T-8 card and relate to the block diagram. In the ingress direction, (Ethernet-to-SONET), the PHY, which performs all of the physical layer interface functions for 10/100 Mbps Ethernet, sends the frame to the network processor for queuing in the respective packet buffer memory. The network processor performs packet processing, packet switching, and classification. The Ethernet frames are then passed to the Ethermap where Ethernet traffic is terminated and is encapsulated using HDLC or GFP framing on a per port basis. The encapsulated Ethernet frames are then mapped into a configurable number of virtual concatenated low and high order payloads, such as VT1.5 synchronous payload envelope (SPE), STS-1 SPE, or a contiguous concatenated payload such as STS-3c SPE. Up to 64 VT1.5 SPEs or 3 STS-1 SPEs can be virtually concatenated. The SONET SPE carrying encapsulated Ethernet frames are passed onto the qMDM FPGA, where four STS-3 frames are multiplexed to form a STS-12 frame for transport over the SONET network by means of the Bridging Convergence Transmission (BTC) ASIC. In the Egress direction (SONET-to-Ethernet), the FPGA extracts four STS-3 SPEs from the STS-12 frame it receives from the BTC and sends each of the STS-3s to the ET3 mappers. The STS-3 SONET SPE carrying GFP or PPP/HDLC encapsulated Ethernet frames is then extracted and buffered in Ethermap’s external memory. This memory is used for providing alignment and differential delay compensation for the received low-order and high-order virtual concatenated payloads. After alignment and delay compensation have been done, the Ethernet frames are decapsulated with one of the framing protocols (GFP or HDLC). Decapsulated Ethernet frames are then passed onto the network processor for QoS queuing and traffic scheduling. The network processor switches the frame to one of the corresponding PHY channels and then to the Ethernet port for transmission to the external client(s). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-29 Chapter 5 Ethernet Cards 5.12.1 CE-100T-8 Card-Level Indicators For information on the CE-100T-8 QoS features, refer to the “CE-100T-8 Operations” chapter of the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. 5.12.1 CE-100T-8 Card-Level Indicators The CE-100T-8 card faceplate has two card-level LED indicators, described in Table 5-23. Table 5-23 CE-100T-8 Card-Level Indicators Card-Level LEDs Description SF LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the CE-100T-8 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the CE-100T-8. When the ACT LED is green, it indicates that the CE-100T-8 card is active and the software is operational. 5.12.2 CE-100T-8 Port-Level Indicators The CE-100T-8 card has two LEDs embedded into each of the eight Ethernet port RJ-45 connectors. The LEDs are described in Table 5-24. Table 5-24 CE-100T-8 Port-Level Indicators Port-Level Indicators Description ACT LED (Amber) A steady amber LED indicates a link is detected, but there is an issue inhibiting traffic. A blinking amber LED means traffic flowing. LINK LED (Green) A steady green LED indicates that a link is detected, but there is no traffic. A blinking green LED flashes at a rate proportional to the level of traffic being received and transmitted over the port. Both ACT and LINK LED OFF Unlit green and amber LEDs indicate no traffic. 5.12.3 Cross-Connect and Slot Compatibility The CE-100T-8 card is compatible in Slots 1 to 6 or 12 to 17 with the XC10G, XC-VXC-10G, or XCVT cards. 5.13 CE-1000-4 Card Note For hardware specifications, see the “A.7.5 CE-1000-4 Card Specifications” section on page A-50. Cisco ONS 15454 Reference Manual, R8.5.x 5-30 78-18106-01 Chapter 5 Ethernet Cards 5.13 CE-1000-4 Card The CE-1000-4 card uses pluggable GBICs to transport Ethernet traffic over a SONET network. The CE-1000-4 provides four IEEE 802.3-compliant, 1000-Mbps Gigabit Ethernet ports at the ingress. At the egress, the CE-1000-4 card provides an integrated Ethernet over SONET mapper with four virtual ports to transfer Ethernet packets over a SONET network. The Ethernet ports automatically configure to operate at either half or full duplex and can determine whether to enable or disable flow control. The Ethernet ports can also be oversubscribed using flow control. The Ethernet frames are encapsulated using the ITU-T generic framing procedure (GFP) (with or without CRC) or LEX, the point-to-point protocol (PPP) with high-level data link control (HDLC). The CE-1000-4 card can interoperate with G1000-4/G1K-4 cards (using LEX encapsulation), CE-100T-8 cards (using LEX or GFP-F), and ML-Series cards (using LEX or GFP-F). The Ethernet frames can be mapped into: • T1X1 G.707-based high-order virtual concatenated (HO VCAT) payloads: – STS-3c – STS-1 • Contiguously concatenated (CCAT) SONET payloads: – Standard CCAT sizes (STS-1, STS-3c, STS-12c, STS-24c, STS-48c) – Non-standard CCAT sizes (STS-6c, STS-9c, STS-18c). To configure a CE-1000-4 card SONET STS or VCAT circuit, refer to the “Create Circuits and Tunnels” chapter in the Cisco ONS 15454 Procedure Guide. The CE-1000-4 card provides multiple management options through Cisco Transport Controller (CTC), Cisco Transport Manager (CTM), Transaction Language 1 (TL1), and Simple Network Management Protocol (SNMP). The CE-1000-4 card supports the software link capacity adjustment scheme (SW-LCAS). This makes it compatible with the ONS 15454 CE-100T-8 and ML-Series cards. The CE-1000-4 card supports VCAT groups (VCGs) that are reconfigurable when SW-LCAS is enabled (flexible VCGs). The CE-1000-4 card does not support the standard hardware-based LCAS. The following guidelines apply to flexible VCGs: • Members can be added or removed from VCGs. • Members can be put into or out of service. • Cross-connects can be added or removed from VCGs. • Errored members will be automatically removed from VCGs. • Adding or removing members from the VCG is service affecting. • Adding or removing cross connects from the VCG is not service affecting if the associated members are not in group. The CE-1000-4 card supports a non link capacity adjustment scheme (no-LCAS). This also makes it compatible with the ONS 15454 CE-100T-8 and ML-Series cards. The CE-1000-4 card supports VCAT groups (VCGs) that are fixed and not reconfigurable when no-LCAS is enabled (fixed VCGs). The following guidelines apply to fixed VCGs: • Members can be added or removed from VCGs using CTC or TL1. • Members cannot be put into or out of service unless the force command mode is instantiated. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-31 Chapter 5 Ethernet Cards 5.13 CE-1000-4 Card Note This is possible with CTC as it assumes the force command mode by default. However, to put members into or out of service using TL1, the force command mode must be set. Cross-connects can be added or removed from VCGs using CTC or TL1. This is service affecting as long as the VCG size (TXCOUNT) is not realigned with the loss of connections. • The CE-1000-4 card supports VCAT differential delay and provides these associated features: Note When the Link Integrity Soak Timer value on CE-1000-4 card with VCAT circuit is more than 1400 ms, the transition from IS > OOS > IS causes a delay of up to 1100 ms. • Supports a maximum VCG differential delay of 122 ms in each direction. • Supports all protection schemes (path protection, two-fiber BLSR, four-fiber BLSR) on VCAT circuits that are split-fiber routed. • Supports 2-fiber on VCAT circuits that are common-fiber routed. • Differential delay compensation is automatically enabled on VCAT circuits that are diverse (split fiber) routed and disabled on VCAT circuits that are common-fiber routed. Figure 5-12 shows the CE-1000-4 card faceplate and block diagram. Figure 5-12 CE-1000-4 Faceplate and Block Diagram CE-1000-4 FAIL 8260 Processor, SDRAM Flash and DecodePLD ACT GBIC Protect RX BPIA SERDES Protect TX BPIA Rx 1 Tx GBIC ACT/LNK Rx 2 SERDES Malena FPGA Altera 4 ports: GigE Tx ACT/LNK GBIC TADM SERDES Main RX BPIA CDR Framer Rx 3 Tx ACT/LNK GBIC Rx 4 SERDES BUFFER MEMORY Tx CLOCK Generation 50MHz,100Mhz 125Mhz,155MHz Diff. Delay. Mem. POWER 5V, 3.3V, 2.5V, 1.8V, -1.7V Main TX BPIA -48V 145231 ACT/LNK Quicksilver FPGA STS48 BACKPLANE Interface BTC 192 Cisco ONS 15454 Reference Manual, R8.5.x 5-32 78-18106-01 Chapter 5 Ethernet Cards 5.13.1 CE-1000-4 Card-Level Indicators 5.13.1 CE-1000-4 Card-Level Indicators The CE-1000-4 card faceplate has two card-level LED indicators, described in Table 5-25. Table 5-25 Note CE-1000-4 Card-Level Indicators Card-Level LEDs Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the CE-1000-4 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the CE-1000-4 card. When the ACT LED is green, it indicates that the CE-1000-4 card is active and the software is operational. If the CE-1000-4 card is inserted in a slot that has been preprovisioned for a different type of card, the red FAIL LED and the green ACT LED will flash alternately until the configuration mismatch is resolved. 5.13.2 CE-1000-4 Port-Level Indicators The CE-1000-4 card provides a pair of LEDs for each Gigabit Ethernet port: an amber LED for activity (ACT) and a green LED for link status (LINK). Table 5-26 describes the status that each color represents. Table 5-26 CE-1000-4 Port-Level Indicators Port-Level Indicators Description Off No link exists to the Ethernet port. Steady amber A link exists to the Ethernet port, but traffic flow is inhibited. For example, a lack of circuit setup, an error on the line, or a disabled port might inhibit traffic flow. Solid green A link exists to the Ethernet port, but no traffic is carried on the port. Flashing green A link exists to the Ethernet port, and traffic is carried on the port. The LED flash rate reflects the traffic rate for that port. 5.13.3 Cross-Connect and Slot Compatibility The CE-1000-4 card can be installed in Slots 1 to 6 and 12 to 17 when used with the XC10G and XC-VXC-10G cards. When the shelf uses the XCVT card, the CE-1000-4 card can only be installed in Slots 5, 6, 12, and 13. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-33 Chapter 5 Ethernet Cards 5.14 CE-MR-10 Card 5.14 CE-MR-10 Card Note For hardware specifications, see the “A.7.7 CE-MR-10 Card Specifications” section on page A-51. The CE-MR-10 card provides ten IEEE 802.3-compliant 10/100/1000-Mbps Gigabit Ethernet ports at the ingress. At the egress, the CE-MR-10 card provides an integrated Ethernet-over-SONET mapper with ten virtual ports to transfer Ethernet packets over a SONET network. The CE-MR-10 card uses pluggable SFPs to transport Ethernet traffic over a SONET network. SFP modules are offered as separate orderable products for flexibility. For details, see the “5.15 Ethernet Card GBICs and SFPs” section on page 5-36. The Ethernet frames are encapsulated using the ITU-T generic framing procedure (GFP) (with or without CRC) or LEX, the Point-to-Point Protocol (PPP) with high-level data link control (HDLC). The Ethernet ports automatically configure to operate at either half or full duplex and can determine whether to enable or disable flow control. The Ethernet ports can also be oversubscribed using flow control. The CE-MR-10 card supports the link capacity adjustment scheme (LCAS), which allows hitless dynamic adjustment of SONET link bandwidth. The CE-MR-10 card's LCAS is hardware-based, but the CE-MR-10 also supports software LCAS (SW-LCAS). This makes it compatible with ML-Series cards, which support only SW-LCAS, along with G-Series and CE-Series cards. The CE-MR-10 card also supports the non link capacity adjustment scheme (non-LCAS). The CE-MR-10 card supports both flexible and fixed VCAT groups (VCG). The Ethernet frames can be mapped into: • T1X1 G.707-based high-order virtual concatenated (HO VCAT) payloads – STS-3c-nv, where n is 1 to 7 – STS-1-nv, where n is 1 to 21 • T1X1 G.707-based low-order virtual concatenated (LO VCAT) payloads – VT1.5-nv, where n is 1 to 64 • Contiguously concatenated (CCAT) SONET payloads – Standard CCAT sizes (STS-1, STS-3c, STS-12c, STS-24c, and STS-48c) – Non-standard CCAT sizes (STS-6c and STS-9c) To configure a CE-MR-10 card circuit, refer to the “Create Circuits and Tunnels” chapter in the Cisco ONS 15454 Procedure Guide. The CE-MR-10 card provides multiple management options through CTC, CTM, TL1, and SNMP. Figure 5-13 shows the CE-MR-10 card faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 5-34 78-18106-01 Chapter 5 Ethernet Cards 5.14.1 CE-MR-10 Card-Level Indicators Figure 5-13 CE-MR-10 Faceplate and Block Diagram CE-MR 10 FAIL ACT LINK ACT T X FCC (2x) 1 MPC8555 Subsystem R X ACT T X 2 SFP R X LINK ACT T X SFP BCM5482S PHY 3 R X LINK ACT T X SFP 4 R X LINK ACT 5 ACT T X 6 R X LINK T X ACT 7 R X LINK ACT 8 ACT MP41 FPGA BCM5482S PHY SFP SFP SFP SFP BCM5482S PHY BCM5482S PHY T X R X LINK SP14 MEM MEM T X R X LINK SFP Marvell 10G MAC T X 9 SFP SFP QDR2 1Mx36 QDR2 1Mx36 RLDRAM2 MEM 8Mx36 SP14 MV82119 35mm MEM SP14 MP4E FPGA BCM5482S PHY Super Carrera SP14 ASIC IBPIA IBPIA B a c k p l a n e RLDRAM2 8Mx36 FCC (2x) 159724 LINK R X LINK T X ACT 10 R X Note The backplane capacity of the CE-MR-10 card is 10 Gigabit Ethernet Ports in slots 5, 6, 12, and 13 and 2.5 Gigabit Ethernet Ports in slots 1 to 4 and 14 to 17. 5.14.1 CE-MR-10 Card-Level Indicators The CE-MR-10 card faceplate has two card-level LED indicators, described in Table 5-27. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-35 Chapter 5 Ethernet Cards 5.14.2 CE-MR-10 Port-Level Indicators Table 5-27 CE-MR-10 Card-Level Indicators Card-Level LEDs Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational. ACT LED (Green) The green ACT LED provides the operational status of the CE-1000-4 card. When the ACT LED is green, it indicates that the CE-1000-4 card is active and the software is operational. 5.14.2 CE-MR-10 Port-Level Indicators The CE-MR-10 card provides a pair of LEDs for each port: an amber LED for activity (ACT) and a green LED for link status (LINK). Table 5-28 describes the status that each color represents. Table 5-28 CE-MR-10 Port-Level Indicators Port-Level Indicators Description Off No link exists to the Ethernet port. Steady amber A link exists to the Ethernet port, but traffic flow is inhibited. For example, a lack of circuit setup, an error on the line, or a disabled port might inhibit traffic flow. Solid green A link exists to the Ethernet port, but no traffic is carried on the port. Flashing green A link exists to the Ethernet port, and traffic is carried on the port. The LED flash rate reflects the traffic rate for that port. 5.14.3 Cross-Connect and Slot Compatibility The CE-MR-10 card can be installed in Slots 1 to 6 and 12 to 17 when used with the XC10G and XC-VXC-10G cards. It is not compatible with the XVT card. Caution Fan-tray assembly 15454-CC-FTA (ANSI shelf) must be installed in a shelf where a CE-MR-10 card is installed. 5.15 Ethernet Card GBICs and SFPs This section describes the GBICs and SFPs used with the Ethernet cards. The ONS 15454 Ethernet cards use industry standard SFPs and GBIC modular receptacles. The ML-MR-10, ML100X-8, ML1000-2, and CE-MR-10 cards use standard Cisco SFPs. The Gigabit E-Series, G-1K-4, and CE-1000-4 cards use standard Cisco GBICs. With Software Release 4.1 and later, G-Series cards can also be equipped with dense wavelength division multiplexing (DWDM) and coarse wavelength division multiplexing (CWDM) GBICs to function as Gigabit Ethernet transponders. Cisco ONS 15454 Reference Manual, R8.5.x 5-36 78-18106-01 Chapter 5 Ethernet Cards 5.15.1 Compatibility by Card For all Ethernet cards, the type of GBIC or SFP plugged into the card is displayed in CTC and TL1. Cisco offers SFPs and GBICs as separate orderable products. 5.15.1 Compatibility by Card Table 5-29 shows the GBICs for the E1000-2-G, G1K-4, or CE-1000-4 cards. Note The GBICs are very similar in appearance. Check the GBIC label carefully before installing it. Table 5-29 Available GBICs GBIC Associated Cards Application Fiber Product Number 1000BASE-S E1000-2-G Short reach X G1K-4 CE-1000-4 Multimode fiber up to 550 m 15454E-GBIC-SX= long 15454-GBIC-SX ONS-GC-GE-SX 1000BASE-L E1000-2-G Long reach X G1K-4 CE-1000-4 Single-mode fiber up to 5 km long 15454E-GBIC-LX= 15454-GBIC-LX ONS-GC-GE-LX 1000BASE-Z G1K-4 Extra long reach X CE-1000-4 Single-mode fiber up to 70 km long 15454E-GBIC-ZX= 15454-GBIC-ZX ONS-GC-GE-ZX Table 5-30 shows the available SFPs and XFPs for Ethernet cards. Table 5-30 Available SFPs and XFPs SFP/XFP Associated Cards Application Fiber Product Number 1000BASE-SX ML1000-2 Short reach Multimode fiber up to 550 m long ONS-SC-GE-SX ML-MR-10 CE-MR-10 Short reach 850 nm multimode fiber up to 500 m long ONS-SI-GE-SX ML1000-2 Long reach Single-mode fiber up to 5 km long ONS-SC-GE-LX ML-MR-10 CE-MR-10 Long reach 1310 nm single-mode fiber up to 10 km long ONS-SI-GE-LX 1000BASE-ZX ML-MR-10 CE-MR-10 Extra long reach 1550 nm single-mode fiber ONS-SI-GE-ZX 100BASE-FX ML100X-8 Short reach 1310 nm multimode fiber ONS-SE-100-FX up to 2 km long ML-MR-10 CE-MR-10 Short reach 1310 nm multimode fiber ONS-SI-100-FX 1000BASE-LX Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-37 Chapter 5 Ethernet Cards 5.15.2 GBIC Description Table 5-30 Available SFPs and XFPs (continued) SFP/XFP Associated Cards Application Fiber Product Number 100BASE-LX10 ML100X-8 Long reach 1310 nm single-mode fiber ONS-SE-100-LX10 ML-MR-10 CE-MR-10 Long reach 1310 nm single-mode fiber ONS-SI-100-LX10 10/100/1000BAS ML-MR-10 E-T CE-MR-10 Short reach up to RJ45 100m STP CAT5, CAT5E and CAT6 ONS-SE-ZE-EL 100BASE-BX ML-MR-10 CE-MR-10 1550 nm RX ONS-SE-100-BX10 U 100BASE-BX ML-MR-10 CE-MR-10 1310 nm RX ONS-SE-100-BX10 D 5.15.2 GBIC Description GBICs are integrated fiber optic transceivers that provide high-speed serial links from a port or slot to the network. Various latching mechanisms can be utilized on the GBIC pluggable modules. There is no correlation between the type of latch and the model type (such as SX or LX/LH) or technology type (such as Gigabit Ethernet). See the label on the GBIC for technology type and model. One GBIC model has two clips (one on each side of the GBIC) that secure the GBIC in the slot on the Ethernet card; the other has a locking handle. Both types are shown in Figure 5-14. GBIC dimensions are: • Height 0.39 in. (1 cm) • Width 1.18 in. (3 cm) • Depth 2.56 in. (6.5 cm) GBIC temperature ranges are: • COM—Commercial operating temperature range –5 degrees C to 70 degrees C (23 degrees F to 158 degrees F) • EXT—Extended operating temperature range –5 degrees C to 85 degrees C (23 degrees F to 185 degrees F) • IND—Industrial operating temperature range –40 degrees C to 85 degrees C (-40 degrees F to 185 degrees F) Cisco ONS 15454 Reference Manual, R8.5.x 5-38 78-18106-01 Chapter 5 Ethernet Cards 5.15.3 G1K-4 DWDM and CWDM GBICs Figure 5-14 GBICs with Clips (left) and with a Handle (right) Clip Handle Receiver Transmitter 51178 Receiver Transmitter 5.15.3 G1K-4 DWDM and CWDM GBICs DWDM (15454-GBIC-xx.x, 15454E-GBIC-xx.x) and CWDM (15454-GBIC-xxxx, 15454E-GBIC-xxxx) GBICs operate in an ONS 15454 G-Series card when the card is configured in Gigabit Ethernet Transponding mode or in Ethernet over SONET mode. DWDM and CWDM GBICs are both wavelength division multiplexing (WDM) technologies and operate over single-mode fibers with SC connectors. Cisco CWDM GBIC technology uses a 20 nm wavelength grid and Cisco ONS 15454 DWDM GBIC technology uses a 1 nm wavelength grid. CTC displays the specific wavelengths of the installed CWDM or DWDM GBICs. DWDM wavelengths are spaced closer together and require more precise lasers than CWDM. The DWDM spectrum allows for optical signal amplification. For more information on G-Series card transponding mode, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. The DWDM and CWDM GBICs receive across the full 1300 nm and 1500 nm bands, which includes all CWDM, DWDM, LX/LH, ZX wavelengths, but transmit on one specified wavelength. This capability can be exploited in some of the G-Series transponding modes by receiving wavelengths that do not match the specific transmission wavelength. Note G1000-4 cards support CWDM and DWDM GBICs. G1K-4 cards with the Common Language Equipment Identification (CLEI) code of WM5IRWPCAA (manufactured after August 2003) support CWDM and DWDM GBICs. G1K-4 cards manufactured prior to August 2003 do not support CWDM or DWDM GBICs. The ONS 15454-supported CWDM GBICs reach up to 100 to 120 km over single-mode fiber and support eight wavelengths as shown in Table 5-31. Table 5-31 Supported Wavelengths for CWDM GBICs CWDM GBIC Wavelengths 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm Corresponding GBIC Colors Gray Violet Blue Green Yellow Orange Red Brown Band 49 51 53 55 57 59 61 47 The ONS 15454-supported DWDM GBICs reach up to 100 to 120 km over single-mode fiber and support 32 different wavelengths in the red and blue bands. Paired with optical amplifiers, such as the Cisco ONS 15216, the DWDM GBICs allow maximum unregenerated spans of approximately 300 km (Table 5-32). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-39 Chapter 5 Ethernet Cards 5.15.3 G1K-4 DWDM and CWDM GBICs Table 5-32 Blue Band Supported Wavelengths for DWDM GBICs 1530.33 nm 1531.12 nm 1531.90 nm 1532.68 nm 1534.25 nm 1535.04 nm 1535.82 nm 1536.61 nm 1538.19 nm 1538.98 nm 1539.77 nm 1540.56 nm 1542.14 nm 1542.94 nm 1543.73 nm 1544.53 nm Red Band 1546.12 nm 1546.92 nm 1547.72 nm 1548.51 nm 1550.12 nm 1550.92 nm 1551.72 nm 1552.52 nm 1554.13 nm 1554.94 nm 1555.75 nm 1556.55 nm 1558.17 nm 1558.98 nm 1559.79 nm 1560.61 nm CWDM or DWDM GBICs for the G-Series card come in set wavelengths and are not provisionable. The wavelengths are printed on each GBIC, for example, CWDM-GBIC-1490. The user must insert the specific GBIC transmitting the wavelength required to match the input of the CWDM/DWDM device for successful operation (Figure 5-15). Follow your site plan or network diagram for the required wavelengths. Figure 5-15 CWDM GBIC with Wavelength Appropriate for Fiber-Connected Device G1K FAIL ACT RX 1470-nm Input 1 TX ACT/LINK RX 2 TX Fiber Optic Connection ACT/LINK RX CWDM Mux 3 TX CWDM-GBIC-1470 ACT/LINK RX 4 TX 90957 ACT/LINK A G-Series card equipped with CWDM or DWDM GBICs supports the delivery of unprotected Gigabit Ethernet service over Metro DWDM (Figure 5-16). It can be used in short-haul and long-haul applications. Cisco ONS 15454 Reference Manual, R8.5.x 5-40 78-18106-01 Chapter 5 Ethernet Cards 5.15.4 SFP Description Figure 5-16 G-Series with CWDM/DWDM GBICs in Cable Network Conventional GigE signals GigE / GigE / GigE over 's HFC CWDM/DWDM ONS Node Mux only with G-Series Cards with CWDM/DWDM GBICs CWDM/DWDM Demux only QAM 90954 VoD = Lambdas 5.15.4 SFP Description SFPs are integrated fiber-optic transceivers that provide high-speed serial links from a port or slot to the network. Various latching mechanisms can be utilized on the SFP modules. There is no correlation between the type of latch and the model type (such as SX or LX/LH) or technology type (such as Gigabit Ethernet). See the label on the SFP for technology type and model. One type of latch available is a mylar tab (Figure 5-17), a second type of latch available is an actuator/button (Figure 5-18), and a third type of latch is a bail clasp (Figure 5-19). SFP dimensions are: • Height 0.03 in. (8.5 mm) • Width 0.53 in. (13.4 mm) • Depth 2.22 in. (56.5 mm) SFP temperature ranges for are: • COM—Commercial operating temperature range –5 degrees C to 70 degrees C (23 degrees F to 158 degrees F) • EXT—Extended operating temperature range –5 degrees C to 85 degrees C (23 degrees F to 185 degrees F) • IND—Industrial operating temperature range –40 degrees C to 85 degrees C (-40 degrees F to 185 degrees F) Mylar Tab SFP 63065 Figure 5-17 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 5-41 Chapter 5 Ethernet Cards 5.15.4 SFP Description Actuator/Button SFP Figure 5-19 Bail Clasp SFP 63067 63066 Figure 5-18 Cisco ONS 15454 Reference Manual, R8.5.x 5-42 78-18106-01 CH A P T E R 6 Storage Access Networking Cards Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. The Fibre Channel Multirate 4-Port (FC_MR-4) card is a 1.0625- or 2.125-Gbps Fibre Channel/fiber connectivity (FICON) card that integrates non-SONET framed protocols into a SONET time-division multiplexing (TDM) platform through virtually concatenated payloads. For installation and step-by-step circuit configuration procedures, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 6.1 FC_MR-4 Card Overview, page 6-1 • 6.2 FC_MR-4 Card Modes, page 6-4 • 6.3 FC_MR-4 Card Application, page 6-7 • 6.4 FC_MR-4 Card GBICs, page 6-8 6.1 FC_MR-4 Card Overview Note For hardware specifications, see the “A.8 Storage Access Networking Card Specifications” section on page A-53. The FC_MR-4 card uses pluggable Gigabit Interface Converters (GBICs) to transport non-SONET/SDH-framed, block-coded protocols over SONET/SDH. The FC_MR-4 enables four client Fibre Channel (FC) ports to be transported over SONET/SDH, encapsulating the frames using the ITU-T generic framing procedure (GFP) format and mapping them into either T1X1 G.707-based virtual concatenated (VCAT) payloads or standard contiguously concatenated SONET payloads. The FC_MR-4 card has the following features: • Four FICON ports operating at 1 Gbps or 2 Gbps – All four ports can be operational at any time due to subrate support – Advanced distance extension capability (buffer-to-buffer credit spoofing) • Pluggable GBIC optics Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 6-1 Chapter 6 Storage Access Networking Cards 6.1 FC_MR-4 Card Overview – Dual rate (1G/2G): MM (550 m) and SM (10 km) – Single rate (1G): SX (550 m) and LX (10 km) • SONET/SDH support – Four 1.0625-Gbps FC channels can be mapped into one of the following: SONET containers as small as STS1-1v (subrate) SDH containers as small as VC4-1v (subrate) SONET/SDH containers as small as STS-18c/VC4-6v (full rate) – Four 2.125-Gbps FC channels can be mapped into one of the following: SONET containers as small as STS1-1v (subrate) SDH containers as small as VC4-1v (subrate) SONET/SDH containers as small as STS-36c/VC4-12v (full rate) • Frame encapsulation: ITU-T G.7041 transparent generic framing procedure (GFP-T) • High-order SONET/SDH VCAT support (STS1-Xv and STS-3c-Xv/VC4-Xv) • Differential delay support for VCAT circuits • Interoperation with the Cisco MDS 9000 switches Figure 6-1 shows the FC_MR-4 faceplate and block diagram. Cisco ONS 15454 Reference Manual, R8.5.x 6-2 78-18106-01 Chapter 6 Storage Access Networking Cards 6.1.1 FC_MR-4 Card-Level Indicators Figure 6-1 FC_MR-4 Faceplate and Block Diagram FC_MR-4 FAIL ACT FLASH SDRAM MPC8250 Decode and Control PLD GBIC OPTICS Rx 1 Tx ACT/LNK Rx 2 GBIC OPTICS SERDES GBIC OPTICS Tx RUDRA FPGA TADM BTC 192 IBPIA ACT/LNK CDR + SONET FRAMER GBIC OPTICS Rx 3 Tx ACT/LNK Rx 4 Tx QDR MEMORY QUICKSILVER VCAT PROCESSOR IBPIA B A C K P L A N E DDR MEMORY 110595 ACT/LNK 6.1.1 FC_MR-4 Card-Level Indicators Table 6-1 describes the two card-level LEDs on the FC_MR-4 card. Table 6-1 FC_MR-4 Card-Level Indicators Card-Level Indicators Description FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready. Replace the card if the red FAIL LED persists. ACT LED (Green) If the ACT/STBY LED is green, the card is operational and ready to carry traffic. ACT LED (Amber) If the ACT/STBY LED is amber, the card is rebooting. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 6-3 Chapter 6 Storage Access Networking Cards 6.1.2 FC_MR-4 Port-Level Indicators 6.1.2 FC_MR-4 Port-Level Indicators Each FC_MR-4 port has a corresponding ACT/LNK LED. The ACT/LNK LED is solid green if the port is available to carry traffic, is provisioned as in-service, and is in the active mode. The ACT/LNK LED is flashing green if the port is carrying traffic. The ACT/LNK LED is steady amber if the port is not enabled and the link is connected, or if the port is enabled and the link is connected but there is a SONET/SDH transport error. The ACT/LNK LED is not lit if there is no link. You can find the status of the card ports using the LCD screen on the ONS 15454 SDH fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages. 6.1.3 FC_MR-4 Compatibility The FC_MR-4 cards can be installed in Slots 1 to 6 and 12 to 17 when used with the XC10G and XC-VXC-10G cards. When the shelf uses the XCVT card, the FC_MR-4 can be used in only the high-speed (slots 5/6 and 12/13). The FC_MR-4 card can be provisioned as part of any valid ONS 15454 SONET/SDH network topology, such as a path protection, bidirectional line switched ring (BLSR), or linear network topologies. The FC_MR-4 card is compatible with Software Release 4.6 and greater. 6.2 FC_MR-4 Card Modes The FC_MR-4 card can operate in two different modes: • Line rate mode—This mode is backward compatible with the Software R4.6 Line Rate mode. • Enhanced mode—This mode supports subrate, distance extension, differential delay, and other enhancements. The FC_MR-4 card reboots when a card mode changes (a traffic hit results). The Field Programmable Gate Array (FPGA) running on the card upgrades to the required image. However, the FPGA image in the card’s flash memory is not modified. 6.2.1 Line-Rate Card Mode The mapping for the line rate card mode is summarized here. • 1 Gbps Fibre Channel/FICON is mapped into: – STS-24c, STS-48c – VC4-8c, VC4-16c – STS1-Xv where X is 19 to 24 – STS3c-Xv where X is 6 to 8 – VC4-Xv where X is 6 to 8 • 2 Gbps Fibre Channel/FICON is mapped into: – STS-48c – VC4-16c Cisco ONS 15454 Reference Manual, R8.5.x 6-4 78-18106-01 Chapter 6 Storage Access Networking Cards 6.2.2 Enhanced Card Mode – STS-1-Xv where X is 37 to 48 – STS-3c-Xv where X is 12 to 16 – VC4-Xv where X is 12 to 16 6.2.2 Enhanced Card Mode The features available in enhanced card mode are given in this section. 6.2.2.1 Mapping 1 Gbps Fibre Channel/FICON is mapped into: – STS-1, STS-3c, STS-6c, STS-9c, STS-12c, STS-18c, STS-24c, STS-48c – VC4-1c, VC4-2c, VC4-3c, VC4-4c, VC4-6c, VC4-8c, VC4-16c – STS-1-Xv where X is 1 to 24 – STS-3c-Xv where X is 1 to 8 – VC4-Xv where X is 1 to 8 2 Gbps Fibre Channel/FICON is mapped into: – STS-1, STS-3c, STS-6c, STS-9c, STS-12c, STS-18c, STS-24c, STS-36c, STS-48c – VC4-1c, VC4-2c, VC4-3c, VC4-4c, VC4-6c, VC4-8c, VC4-12c, VC4-16c – STS-1-Xv where X is 1 to 48 – STS-3c-Xv where X is 1 to 16 – VC4-Xv where X is 1 to 16 6.2.2.2 SW -LCAS VCAT group (VCG) is reconfigurable when the software link capacity adjustment scheme (SW-LCAS) is enabled, as follows: • Out-of-service (OOS) and out-of-group (OOG) members can be removed from VCG • Members with deleted cross-connects can be removed from VCGs • Errored members can be autonomously removed from VCGs • Degraded bandwidth VCGs are supported • VCG is flexible with SW-LCAS enabled (VCG can run traffic as soon as the first cross-connect is provisioned on both sides of the transport) 6.2.2.3 Distance Extension This following list describes the FC_MR-4 card distance extension capabilities: • Enabling of a storage access networking (SAN) extension over long distances through buffer-to-buffer (B2B) credit spoofing. – 2300 km for 1G ports (longer distances supported with lesser throughput) – 1150 km for 2G ports (longer distances supported with lesser throughput) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 6-5 Chapter 6 Storage Access Networking Cards 6.2.2 Enhanced Card Mode • Negotiation mechanism to identify whether a far-end FC-over-SONET card supports the Cisco proprietary B2B mechanism • Auto detection of FC switch B2B credits from FC-SW standards-based exchange link parameters (ELP) frames • Support for manual provisioning of credits based on FC switch credits • Automatic GFP buffers adjustment based on roundtrip latency between two SL ports • Automatic credits recovery during SONET switchovers/failures • Insulation for FC switches from any SONET switchovers; no FC fabric reconvergences for SONET failures of less than or equal to 60 ms 6.2.2.4 Differential Delay Features The combination of VCAT, SW-LCAS, and GFP specifies how to process information for data and storage clients. The resulting operations introduce delays. Their impact depends on the type of service being delivered. For example, storage requirements call for very low latency, as opposed to traffic such as e-mail where latency variations are not critical. With VCAT, SONET paths are grouped to aggregate bandwidth to form VCGs. Because each VCG member can follow a unique physical route through a network, there are differences in propagation delay, and possibly processing delays between members. The overall VCG propagation delay corresponds to that of the slowest member. The VCAT differential delay is the relative arrival time measurement between members of a VCG. The FC_MR-4 card is able to handle VCAT differential delay and provides these associated features: Note • Supports a maximum of 122 ms of delay difference between the shortest and longest paths. • Supports diverse fiber routing for VCAT circuit. • All protection schemes are supported (path protection, automatic protection switching [APS], 2-fiber BLSR, 4-fiber BLSR). • Supports routing of VCAT group members through different nodes in the SONET network. • Differential delay compensation is automatically enabled on VCAT circuits that are diverse (split fiber) routed, and disabled on VCAT circuits that are common fiber routed. Differential delay support for VCAT circuits is supported by means of a TL1 provisioning parameter (EXTBUFFERS) in the ENT-VCG command. 6.2.2.5 Interoperability Features The interoperability features are as follows: • Maximum frame size setting to prevent accumulation of oversized performance monitoring parameters for virtual SAN (VSAN) frames • Ingress filtering disable for attachment to third-party GFP-over-SONET/SDH equipment • String (port name) provisioning for each fiber channel and FICON interface on the FC_MR-4 card to allow the MDS Fabric Manager to create link association between a SAN port on a Cisco MDS 9000 switch and the FC_MR-4 SAN port. Cisco ONS 15454 Reference Manual, R8.5.x 6-6 78-18106-01 Chapter 6 Storage Access Networking Cards 6.2.3 Link Integrity 6.2.3 Link Integrity The link integrity features are as follows: • Data port disabled if upstream data port is not able to send over SONET/SDH transport • Data port disabled if SONET/SDH transport is errored 6.2.4 Link Recovery Link recovery has the following features: Note • Reduces the impact of SONET/SDH disruptions on attached Fibre Channel equipment • Speeds up the recovery of Inter-Switch Links (ISLs) • Allows monitoring of B2B credit depletion due to SONET outage and full recovery of the credits, thus preventing the slow decay of bandwidth/throughput Distance extension and link recovery cannot be enabled at the same time. 6.3 FC_MR-4 Card Application The FC_MR-4 card reliably transports carrier-class, private-line Fibre Channel/FICON transport service. Each FC_MR-4 card can support up to four 1-Gbps circuits or four 2-Gbps circuits. Four 1.0625-Gbps FC channels can be mapped into containers as small as STS-1 (subrate), with a minimum of STS-18c/VC4-6v for full rate. Four 2.125-Gbps FC channels can be mapped into containers as small as STS-1 (sub-rate), with a minimum of STS-36c/VC4-12v for full rate. The FC_MR-4 card incorporates features optimized for carrier-class applications such as: Note • Carrier-class Fibre Channel/FICON • 50 ms of switch time through SONET/SDH protection as specified in Telcordia GR-253-CORE Protection switch traffic hit times of less than 60 ms are not guaranteed with differential delay in effect. • Note Hitless software upgrades Hitless software upgrades are not possible with an activation from Software R5.0 to Software R6.0 or higher in enhanced card mode. This is because the FPGA must be upgraded to support differential delay in enhanced mode. Upgrades are still hitless with the line rate mode. • Remote Fibre Channel/FICON circuit bandwidth upgrades through integrated Cisco Transport Controller (CTC) • Multiple management options through CTC, Cisco Transport Manager (CTM), TL1, and Simple Network Management Protocol (SNMP) • Differential delay compensation of up to 122 ms for diversely routed VCAT circuits The FC_MR-4 payloads can be transported over the following protection types: Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 6-7 Chapter 6 Storage Access Networking Cards 6.4 FC_MR-4 Card GBICs • Path protection • BLSR • Unprotected • Protection channel access (PCA) The FC_MR-4 payloads can be transported over the following circuit types: Note • STS • STSn • STS-V Virtual Tributary (VT) and VT-V circuits are not supported. The FC_MR-4 card supports VCAT. See the “11.18 Virtual Concatenated Circuits” section on page 11-34 for more information about VCAT circuits. 6.4 FC_MR-4 Card GBICs The FC_MR-4 uses pluggable GBICs for client interfaces. Table 6-2 lists GBICs that are compatible with the FC_MR-4 card. See the “5.15.2 GBIC Description” section on page 5-38 for more information. Table 6-2 GBIC Compatibility Card FC_MR-4 (ONS 15454 SONET/SDH) Compatible GBIC or SFP (Cisco Product ID) Cisco Top Assembly Number (TAN) 15454-GBIC-SX 15454E-GBIC-SX 15454-GBIC-LX/LH 15454E-GBIC-LX/LH ONS-GX-2FC-MMI ONS-GX-2FC-SML 30-0759-01 800-06780-01 10-1743-01 30-0703-01 10-2015-01 10-2016-01 Cisco ONS 15454 Reference Manual, R8.5.x 6-8 78-18106-01 CH A P T E R 7 Card Protection This chapter explains the Cisco ONS 15454 card protection configurations. To provision card protection, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 7.1 Electrical Card Protection, page 7-1 • 7.2 Electrical Card Protection and the Backplane, page 7-5 • 7.3 OC-N Card Protection, page 7-13 • 7.4 Unprotected Cards, page 7-14 • 7.5 External Switching Commands, page 7-14 7.1 Electrical Card Protection The ONS 15454 provides a variety of electrical card protection methods. This section describes the protection options. Figure 7-1 on page 7-2 shows a 1:1 protection configuration and Figure 7-2 on page 7-3 shows a 1:N protection configuration. This section covers the general concept of electrical card protection. Specific electrical card protection schemes depend on the type of electrical card as well as the electrical interface assembly (EIA) type used on the ONS 15454 backplane. Table 7-4 on page 7-6 details the specific electrical card protection schemes. Note Caution See Table 1-1 on page 1-16 and Table 1-2 on page 1-17 for the EIA types supported by the 15454-SA-ANSI and 15454-SA-HD (high-density) shelf assemblies. When a protection switch moves traffic from the working/active electrical card to the protect/standby electrical card, ports on the new active/standby card cannot be placed out of service as long as traffic is switched. Lost traffic can result when a port is taken out of service, even if the standby card no longer carries traffic. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 7-1 Chapter 7 Card Protection 7.1.1 1:1 Protection 7.1.1 1:1 Protection In 1:1 protection, a working card is paired with a protect card of the same type. If the working card fails, the traffic from the working card switches to the protect card. You can provision 1:1 to be revertive or nonrevertive. If revertive, traffic automatically reverts to the working card after the failure on the working card is resolved. Figure 7-1 shows an example of the ONS 15454 in a 1:1 protection configuration. Each working card in an even-numbered slot is paired with a protect card in an odd-numbered slot: Slot 1 is protecting Slot 2, Slot 3 is protecting Slot 4, Slot 5 is protecting Slot 6, Slot 17 is protecting Slot 16, Slot 15 is protecting Slot 14, and Slot 13 is protecting Slot 12. Figure 7-1 Example: ONS 15454 Cards in a 1:1 Protection Configuration (SMB EIA) 33384 Protect Working Protect Working Protect Working TCC+ XC10G AIC (Optional) XC10G Working TCC+ Protect Working Protect Working Protect 1:1 Protection Table 7-1 provides supported 1:1 protection by electrical card type. Table 7-1 Supported 1:1 Protection by Electrical Card Working Card Protect Card Working Slot Protection Slot DS1-14 or DS1N-14 DS1-14 or DS1N-14 2 1 DS3-12/DS3-12E or DS3N-12/DS3N-12E DS3-12 or DS3N-12 4 3 DS3i-N-12 DS3i-N-12 6 5 DS3XM-6 (Transmux) DS3XM-6 (Transmux) 12 13 DS3XM-12 (Transmux) DS3XM-12 (Transmux) 14 15 16 17 Cisco ONS 15454 Reference Manual, R8.5.x 7-2 78-18106-01 Chapter 7 Card Protection 7.1.2 1:N Protection 7.1.2 1:N Protection 1:N protection allows a single electrical card to protect up to five working cards of the same speed. 1:N cards have added circuitry to act as the protect card in a 1:N protection group. Otherwise, the card is identical to the standard card and can serve as a normal working card. The physical DS-1 or DS-3 interfaces on the ONS 15454 backplane use the working card until the working card fails. When the node detects this failure, the protect card takes over the physical DS-1 or DS-3 electrical interfaces through the relays and signal bridging on the backplane. Figure 7-2 shows the ONS 15454 in a 1:N protection configuration. Each side of the shelf assembly has only one card protecting all of the cards on that side. Figure 7-2 Example: ONS 15454 Cards in a 1:N Protection Configuration (SMB EIA) 1:N Protection 32106 Working Working 1:N Protection Working Working Working TCC+ XC10G AIC (Optional) TCC+ XC10G Working Working Working 1:N Protection Working Working Table 7-2 provides the supported 1:N configurations by electrical card, as well as the card types that can be used for working and protection cards. Additional engineering rules for 1:N card deployments will be covered in the following sections. Table 7-2 Supported 1:N Protection by Electrical Card Working Card Protect Card Protect Group (Maximum) Working Slot Protection Slot DS1-14 or DS1N-14 DS1N-14 N<5 1, 2, 4, 5, 6 3 12, 13, 14, 16, 17 15 DS1/E1-56 DS1/E1-56 N<2 1 1,2 3 2 16 , 17 DS3-12/DS3-12E or DS3N-12/DS3N-12E DS3N-12/DS3N-12E N < 5 DS3i-N-12 DS3i-N-12 N<5 3 4 15 1, 2, 4, 5, 6 3 12, 13, 14, 16, 17 15 1, 2, 4, 5, 6 3 12, 13, 14, 16, 17 15 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 7-3 Chapter 7 Card Protection 7.1.2 1:N Protection Table 7-2 Supported 1:N Protection by Electrical Card (continued) Working Card DS3/EC1-48 Protect Card Protect Group (Maximum) Working Slot Protection Slot DS3/EC1-48 N<2 3 5 1,2 7 6 16 , 17 DS3XM-12 (Transmux) DS3XM-12 (Transmux) N<5 DS3XM-12 (Transmux) DS3XM-12 (Transmux) N<7 (portless9) 8 15 1, 2, 4, 5, 6 3 12, 13, 14, 16, 17 15 1, 2, 4, 5, 6, 12, 13, 3 14, 15, 16, 17 1, 2, 3, 4, 5, 6, 12, 15 13, 14, 16, 17 1. A high-density electrical card inserted in Slot 1 restricts the use of Slots 5 and 6 to optical, data, or storage cards. 2. A high-density electrical card inserted in Slot 2 restricts the use of Slots 4 and 6 to optical, data, or storage cards. 3. A high-density electrical card inserted in Slot 16 restricts the use of Slot 14 to optical, data, or storage cards. 4. A high-density electrical card inserted in Slot 17 restricts the use of Slots 12 and 13 to optical, data, or storage cards. 5. A high-density electrical card inserted in Slot 1 restricts the use of Slots 5 and 6 to optical, data, or storage cards. 6. A high-density electrical card inserted in Slot 2 restricts the use of Slots 4 and 6 to optical, data, or storage cards. 7. A high-density electrical card inserted in Slot 16 restricts the use of Slot 14 to optical, data, or storage cards. 8. A high-density electrical card inserted in Slot 17 restricts the use of Slots 12 and 13 to optical, data, or storage cards. 9. Portless DS-3 Transmux operation does not terminate the DS-3 signal on the EIA panel. 7.1.2.1 Revertive Switching 1:N protection supports revertive switching. Revertive switching sends the electrical interfaces (traffic) back to the original working card after the card comes back online. Detecting an active working card triggers the reversion process. There is a variable time period for the lag between detection and reversion, called the revertive delay, which you can set using the ONS 15454 software, Cisco Transport Controller (CTC). To set the revertive delay, refer to the “Turn Up a Node” chapter in the Cisco ONS 15454 Procedure Guide. All cards in a protection group share the same reversion settings. 1:N protection groups default to automatic reversion. Caution A user-initiated switch (external switching command) overrides the revertive delay, that is, clearing the switch clears the timer. 7.1.2.2 1:N Protection Guidelines There are two types of 1:N protection groups for the ONS 15454: ported and portless. Ported 1:N interfaces are the traditional protection groups for signals electrically terminated on the shelf assembly. Portless 1:N interfaces are signals received through an electrical synchronous transport signal (STS) through the cross-connect card. The DS3XM-12 card supports portless as well as traditional ported deployments. Table 7-2 on page 7-3 outlines the 1:N configurations supported by each electrical card type. The following rules apply to ported 1:N protection groups in the ONS 15454: • Working and protect card groups must reside in the same card bank (Side A or Side B). • The 1:N protect card must reside in Slot 3 for Side A and Slot 15 for Side B. Cisco ONS 15454 Reference Manual, R8.5.x 7-4 78-18106-01 Chapter 7 Card Protection 7.2 Electrical Card Protection and the Backplane • Working cards can sit on either or both sides of the protect card. The following rules apply to portless 1:N protection groups in the ONS 15454: • Working and protect card groups can reside in the same card bank or different card banks (Side A or Side B). • The 1:N protect card can be installed in either Slot 3 or Slot 15 and protect working cards in both card banks. • Working cards can sit on either or both sides of the protect card. The ONS 15454 supports 1:N equipment protection for all add-drop multiplexer (ADM) configurations (ring, linear, and terminal), as specified by Telcordia GR-253-CORE. For detailed procedures for setting up DS-1 and DS-3 protection groups, refer to the Cisco ONS 15454 Procedure Guide. 7.2 Electrical Card Protection and the Backplane Protection schemes for electrical cards depend on the EIA type used on the ONS 15454 backplane. The difference is due to the varying connector size. For example, because BNC connectors are larger, fewer DS3-12 cards can be supported when using a BNC connector. Table 7-3 shows the number of connectors per side for each EIA type according to low-density and high-density interfaces. In the tables, high-density (HD) cards include the DS3/EC1-48 and DS1/E1-56 cards. Low-density (LD cards) include the following: Note Caution Table 7-3 • DS1-14, DS1N-14 • DS3-12/DS3-12E, DS3N-12/DS3N-12E • DS3XM-6 • DS3XM-12 • EC1-12 For EIA installation, refer to the “Install the Shelf and Backplane Cable” chapter in the Cisco ONS 15454 Procedure Guide. When a protection switch moves traffic from the working/active electrical card to the protect/standby electrical card, ports on the new active/standby card cannot be taken out of service as long as traffic is switched. Lost traffic can result when a port is taken out of service even if the standby electrical card no longer carries traffic. EIA Connectors Per Side Interfaces per Side Standard BNC High-Density BNC MiniBNC SMB UBIC-V and AMP Champ UBIC-H (SCSI) Total physical connectors 48 96 192 168 6 16 Maximum LD DS-1 Interfaces (transmit [Tx] and receive [Rx]) — — — 84 84 84 Maximum LD DS-3 interfaces (Tx and Rx) 24 48 72 72 — 72 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 7-5 Chapter 7 Card Protection 7.2 Electrical Card Protection and the Backplane Table 7-3 EIA Connectors Per Side Interfaces per Side Standard BNC High-Density BNC MiniBNC SMB UBIC-V and AMP Champ UBIC-H (SCSI) Maximum HD DS-1 interfaces (Tx and Rx) — — — — — 112 Maximum HD DS-3 interfaces (Tx and Rx) — — 96 — — 96 Table 7-4 shows the electrical card protection for each EIA type according to shelf side and slots. Table 7-4 Protection Type Electrical Card Protection By EIA Type Side Standard BNC High-Density BNC MiniBNC SMB AMP Champ UBIC-V and UBIC-H (SCSI) A 2, 4 1, 2, 4, 5 1–6 1–6 1–6 1–6 B 14, 16 13, 14, 16, 17 12–17 12–17 12–17 12–17 HD, Working A — — 1, 2 — — 1, 2 B — — 16, 17 — — 16, 17 A 2, 4 2, 4 2, 4, 6 2, 4, 6 2, 4, 6 2, 4, 6 B 14, 16 14, 16 12, 14, 16 12, 14, 16 12, 14, 16 12, 14, 16 A 1, 3 1, 3 1, 3, 5 1, 3, 5 1, 3, 5 B 15, 17 15, 17 13, 15, 17 13, 15, 17 13, 15, 17 13, 15, 17 A — 1, 2, 4, 5 1–6 1–6 1–6 1–6 B — 13, 14, 16, 17 12–17 12–17 12–17 12–17 A — 3 3 3 3 3 B — 15 15 15 15 15 HD, Working A — — 1, 2 — — 1, 2 B — — 16, 17 — — 16, 17 A — — 3 — — 3 B — — 15 — — 15 Card Type Unprotected LD, Working 1:1 LD, Working LD, Protect 1:N LD, Working LD, Protect HD, Protect 1, 3, 5 Cisco ONS 15454 Reference Manual, R8.5.x 7-6 78-18106-01 Working Working Working Working Working Working Working TCC Working Cross-connect Cross-connect AIC TCC Working Working Working Working Working Working Working Working Working TCC Working Working Cross-connect Cross-connect AIC TCC Working Working Working Working Working Working Working Working TCC Cross-connect Cross-connect AIC TCC Working Working Working High-Density BNC Standard BNC MiniBNC SMB/UBIC/AMP Champ Working Working TCC Cross-connect AIC Cross-connect TCC Working Working 124960 Unprotected Low-Density Electrical Card Schemes for EIA Types Figure 7-3 7-7 78-18106-01 Card Protection Chapter 7 7.2 Electrical Card Protection and the Backplane Figure 7-3 shows unprotected low-density electrical card schemes by EIA type. Cisco ONS 15454 Reference Manual, R8.5.x Chapter 7 Card Protection 7.2 Electrical Card Protection and the Backplane Figure 7-4 shows unprotected high-density electrical card schemes by EIA type. Figure 7-4 Unprotected High-Density Electrical Card Schemes for EIA Types 124963 Working Working TCC Cross-connect AIC Cross-connect TCC Working Working UBIC/MiniBNC Cisco ONS 15454 Reference Manual, R8.5.x 7-8 78-18106-01 Chapter 7 Card Protection 7.2 Electrical Card Protection and the Backplane Figure 7-5 shows 1:1 low-density card protection by EIA type. Figure 7-5 1:1 Protection Schemes for Low-Density Electrical Cards with EIA Types Working Protect Protect Working TCC Cross-connect AIC Cross-connect TCC Working Protect Working Protect Protect Working Protect Working TCC Cross-connect AIC Cross-connect TCC Protect Working Protect Working Standard BNC High-Density BNC 124962 Working Protect Protect Working TCC Protect Working Cross-connect AIC Cross-connect TCC Working Protect Protect Working Protect Working SMB/UBIC/AMP Champ/MiniBNC Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 7-9 Chapter 7 Card Protection 7.2 Electrical Card Protection and the Backplane Figure 7-6 shows 1:N protection for low-density electrical cards. Figure 7-6 1:N Protection Schemes for Low-Density Electrical Cards with EIA Types Working Working 1:N Protection Working Working TCC Cross-connect AIC Cross-connect TCC Working Working 1:N Protection Working Working Working 1:N Protection Working TCC Cross-connect AIC Cross-connect TCC Working 1:N Protection Working Standard BNC High-Density BNC 124961 Working Working 1:N Protection Working Working TCC Working Cross-connect AIC Cross-connect TCC Working Working Working 1:N Protection Working Working SMB/UBIC/AMP Champ/MiniBNC Note EC-1 cards do not support 1:N protection. Cisco ONS 15454 Reference Manual, R8.5.x 7-10 78-18106-01 Chapter 7 Card Protection 7.2.1 Standard BNC Protection Figure 7-7 shows 1:1 high-density card protection by EIA type. Figure 7-7 1:1 Protection Schemes for High-Density Electrical Cards with UBIC or MiniBNC EIA Types 124964 Working Working Protect TCC Cross-connect AIC Cross-connect TCC Protect Working Working UBIC/MiniBNC 7.2.1 Standard BNC Protection When used with the standard BNC EIA, the ONS 15454 supports unprotected, 1:1, or 1:N (N < 2) electrical card protection for DS-3 and EC-1 signals, as outlined in Table 7-1 on page 7-2 and Table 7-2 on page 7-3. The standard BNC EIA panel provides 48 BNC connectors for terminating up to 24 transmit and 24 receive signals per EIA panel, enabling 96 BNC connectors for terminating up to 48 transmit and receive signals per shelf with two standard-BNC panels installed. With an A-Side standard BNC EIA, Slots 2 and 4 can be used for working slots and with a B-Side EIA, Slots 14 and 16 can be used for working slots. Each of these slots is mapped to 24 BNC connectors on the EIA to support up to 12 transmit/receive signals. These slots can be used with or without equipment protection for DS-3 and EC-1 services. 7.2.2 High-Density BNC Protection When used with the high-density BNC EIA, the ONS 15454 supports unprotected, 1:1, or 1:N (N < 4) electrical card protection for DS-3 and EC-1 signals, as outlined in Table 7-1 on page 7-2 and Table 7-2 on page 7-3. The high-density BNC EIA panel provides 96 BNC connectors for terminating up to 48 transmit and 24 receive signals per EIA panel, enabling 192 BNC connectors for terminating up to 96 transmit and receive signals per shelf with two high-density BNC panels installed. With an A-Side high-density BNC EIA, Slots 1, 2, 4, and 5 can be used for working slots and with a B-Side EIA, Slots 13, 14, 16, and 17 can be used for working slots. Each of these slots is mapped to 24 BNC connectors on the EIA to support up to 12 transmit/receive signals. These slots can be used with or without equipment protection for DS-3 and EC-1 services. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 7-11 Chapter 7 Card Protection 7.2.3 MiniBNC Protection 7.2.3 MiniBNC Protection When used with the MiniBNC EIA, the ONS 15454 supports unprotected, 1:1, or 1:N (N < 5) electrical card protection for DS-1, DS-3 and EC-1 signals, as outlined in Table 7-1 on page 7-2 and Table 7-2 on page 7-3. The MiniBNC EIA provides 192 MiniBNC connectors for terminating up to 96 transmit and 96 receive signals per EIA, enabling 384 MiniBNC connectors for terminating up to 192 transmit and receive signals per shelf with two MiniBNC panels installed. With an A-Side MiniBNC EIA, Slots 1, 2, 4, 5, and 6 can be used for working slots and on a B-Side panel, Slots 12, 13, 14, 16, and 17 can be used for working slots. Each of these slots is mapped to 24 MiniBNC connectors on the EIA panel to support up to 12 transmit/receive signals. In addition, working Slots 1, 2, 16 and 17 can be mapped to 96 MiniBNC connectors to support the high-density electrical card. These slots can be used with or without equipment protection for DS-3 and EC-1 services. 7.2.4 SMB Protection When used with the SMB EIA, the ONS 15454 supports unprotected, 1:1, or 1:N (N < 5) electrical card protection for DS-3 and EC-1 signals, as outlined in Table 7-1 on page 7-2 and Table 7-2 on page 7-3. The SMB EIA provides 168 SMB connectors for terminating up to 84 transmit and 84 receive signals per EIA, enabling 336 SMB connectors for terminating up to 168 transmit and receive signals per shelf with two SMB EIAs installed. With an A-Side SMB EIA, Slots 1, 2, 3, 4, 5, and 6 can be used for working slots and with a B-Side EIA, Slots 12, 13, 14, 15, 16, and 17 can be used for working slots. Each of these slots is mapped to 28 SMB connectors on the EIA to support up to 14 transmit/receive signals. These slots can be used with or without equipment protection for DS-1, DS-3 and EC-1 services. For DS-1 services, an SMB-to-wire-wrap balun is installed on the SMB ports for termination of the 100 ohm signal. 7.2.5 AMP Champ Protection When used with the AMP Champ EIA, the ONS 15454 supports unprotected, 1:1, or 1:N (N < 5) electrical card protection for DS-1 signals, as outlined in Table 7-1 on page 7-2 and Table 7-2 on page 7-3. The AMP Champ EIA provides 6 AMP Champ connectors for terminating up to 84 transmit and 84 receive signals per EIA, enabling 12 AMP Champ connectors for terminating up to 168 transmit and receive signals per shelf with two AMP Champ EIAs installed. With an A-Side SMB EIA, Slots 1, 2, 3, 4, 5, and 6 can be used for working slots and with a B-Side EIA, Slots 12, 13, 14, 15, 16, and 17 can be used for working slots. Each of these slots is mapped to 1 AMP Champ connector on the EIA to support 14 transmit/receive signals. These slots can be used with or without equipment protection for DS-1 services. 7.2.6 UBIC Protection When used with the UBIC EIA, the ONS 15454 high-density shelf assembly (15454-HD-SA) supports unprotected, 1:1, or 1:N (N < 5) electrical card protection for DS-1, DS-3 and EC-1 signals, as outlined in Table 7-1 on page 7-2 and Table 7-2 on page 7-3. The UBIC EIA provides 16 SCSI connectors for terminating up to 112 transmit and receive DS-1 signals per EIA, or up to 96 transmit and receive DS-3 connections. With an A-side UBIC EIA, Slots 1, 2, 3, 4, 5, and 6 can be used for working slots and with a B-Side EIA, Slots 12, 13, 14, 15, 16, and 17 can be used for working slots. Each of these slots is mapped to two SCSI connectors on the EIA to support up to 14 transmit/receive signals. In addition, working Slots 1, 2, 16, and 17 can be mapped to 8 SCSI connectors to support the high-density electrical card. These slots can be used with or without equipment protection for DS-1, DS-3, and EC-1 services. Cisco ONS 15454 Reference Manual, R8.5.x 7-12 78-18106-01 Chapter 7 Card Protection 7.3 OC-N Card Protection 7.3 OC-N Card Protection The ONS 15454 provides two optical card protection methods, 1+1 protection and optimized 1+1 protection. This section covers the general concept of optical card protection. Specific optical card protection schemes depend on the optical cards in use. 7.3.1 1+1 Protection Any OC-N card can use 1+1 protection. With 1+1 port-to-port protection, ports on the protect card can be assigned to protect the corresponding ports on the working card. Both ports must belong to two different cards and should have the same port number. For example, if port 2 is the protect port on Card A then port 2 on Card B would be the working port. The working and protect cards do not have to be placed side by side in the node. A working card must be paired with a protect card of the same type and number of ports. For example, a single-port OC-12 must be paired with another single-port OC-12, and a four-port OC-12 must be paired with another four-port OC-12. You cannot create a 1+1 protection group if one card is single-port and the other is multiport, even if the OC-N rates are the same. The protection takes place on the port level, and any number of ports on the protect card can be assigned to protect the corresponding ports on the working card. For example, on a four-port card, you can assign one port as a protection port on the protect card (protecting the corresponding port on the working card) and leave three ports unprotected. Conversely, you can assign three ports as protection ports and leave one port unprotected. In other words, all the ports on the protect card are used in the protection scheme. 1+1 span protection can be either revertive or nonrevertive. With nonrevertive 1+1 protection, when a failure occurs and the signal switches from the working card to the protect card, the signal stays switched to the protect card until it is manually switched back. Revertive 1+1 protection automatically switches the signal back to the working card when the working card comes back online. 1+1 protection is unidirectional and nonrevertive by default; revertive switching is easily provisioned using CTC. Note When provisioning a line timing reference for the node, you cannot select the protect port of a 1+1 protection group. If a traffic switch occurs on the working port of the 1+1 protection group, the timing reference of the node automatically switches to the protect port of the 1+1 protection group. 7.3.2 Optimized 1+1 Protection Optimized 1+1 protection is used in networks that mainly use the linear 1+1 bidirectional protection scheme. Optimized 1+1 is a line-level protection scheme using two lines, working and protect. One of the two lines assumes the role of the primary channel, where traffic is selected, and the other line assumes the role of secondary channel, which protects the primary channel. Traffic switches from the primary channel to the secondary channel based on either line conditions or an external switching command performed by the user. After the line condition clears, the traffic remains on the secondary channel. The secondary channel is automatically renamed as the primary channel and the former primary channel is automatically renamed as the secondary channel. Unlike 1+1 span protection, 1+1 optimized span protection does not use the revertive or nonrevertive feature. Also, 1+1 optimized span protection does not use the Manual switch command. The 1+1 optimized span protection scheme is supported only on the Cisco ONS 15454 SONET using either OC3-4 cards or OC3-8 cards with ports that are provisioned for SDH payloads. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 7-13 Chapter 7 Card Protection 7.4 Unprotected Cards Optimized 1+1 is fully compliant with Nippon Telegraph and Telephone Corporation (NTT) specifications. With optimized 1+1 port-to-port protection, ports on the protect card can be assigned to protect the corresponding ports on the working card. The working and protect cards do not have to be installed side by side in the node. A working card must be paired with a protect card of the same type and number of ports. For example, a four-port OC-3 must be paired with another four-port OC-3, and an eight-port OC-3 must be paired with another eight-port OC-3. You cannot create an optimized 1+1 protection group if the number of ports do not match, even if the OC-N rates are the same. The protection takes place on the port level, and any number of ports on the protect card can be assigned to protect the corresponding ports on the working card. For example, on a four-port card, you can assign one port as a protection port on the protect card (protecting the corresponding port on the working card) and leave three ports unprotected. Conversely, you can assign three ports as protection ports and leave one port unprotected. With 1:1 or 1:N protection (electrical cards), the protect card must protect an entire slot. In other words, all the ports on the protect card are used in the protection scheme. 7.4 Unprotected Cards Unprotected cards are not included in a protection scheme; therefore, a card failure or a signal error results in lost data. Because no bandwidth lies in reserve for protection, unprotected schemes maximize the available ONS 15454 bandwidth. Figure 7-8 shows the ONS 15454 in an unprotected configuration. All cards are in a working state. Figure 7-8 ONS 15454 in an Unprotected Configuration 33383 Working Working Working Working Working Working TCC Cross-connect AIC (Optional) TCC Cross-connect Working Working Working Working Working Working Unprotected 7.5 External Switching Commands The external switching commands on the ONS 15454 are Manual, Force, and Lockout. If you choose a Manual switch, the command will switch traffic only if the path has an error rate less than the signal degrade (SD) bit error rate threshold. A Force switch will switch traffic even if the path has SD or signal fail (SF) conditions; however, a Force switch will not override an SF on a 1+1 protection channel. Cisco ONS 15454 Reference Manual, R8.5.x 7-14 78-18106-01 Chapter 7 Card Protection 7.5 External Switching Commands A Force switch has a higher priority than a Manual switch. Lockouts, which prevent traffic from switching to the protect port under any circumstance, can only be applied to protect cards (in 1+1 configurations). Lockouts have the highest priority. In a 1+1 configuration you can also apply a lock on to the working port. A working port with a lock on applied cannot switch traffic to the protect port in the protection group (pair). In 1:1 protection groups, working or protect ports can have a lock on. Note Force and Manual switches do not apply to 1:1 protection groups; these ports have a single switch command. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 7-15 Chapter 7 Card Protection 7.5 External Switching Commands Cisco ONS 15454 Reference Manual, R8.5.x 7-16 78-18106-01 CH A P T E R 8 Cisco Transport Controller Operation This chapter describes Cisco Transport Controller (CTC), the software interface for the Cisco ONS 15454. For CTC set up and login information, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 8.1 CTC Software Delivery Methods, page 8-1 • 8.2 CTC Installation Overview, page 8-4 • 8.3 PC and UNIX Workstation Requirements, page 8-4 • 8.4 ONS 15454 Connection, page 8-7 • 8.5 CTC Login, page 8-7 • 8.6 CTC Window, page 8-8 • 8.7 Using the CTC Launcher Application to Manage Multiple ONS Nodes, page 8-18 • 8.8 TCC2/TCC2P Card Reset, page 8-21 • 8.9 TCC2/TCC2P Card Database, page 8-21 • 8.10 Software Revert, page 8-22 8.1 CTC Software Delivery Methods ONS 15454 provisioning and administration is performed using the CTC software. CTC is a Java application that is installed in two locations; CTC is stored on the Advanced Timing, Communications, and Control (TCC2) card or the Advanced Timing, Communications, and Control Plus (TCC2P) card, and it is downloaded to your workstation the first time you log into the ONS 15454 with a new software release. 8.1.1 CTC Software Installed on the TCC2/TCC2P Card CTC software is preloaded on the ONS 15454 TCC2/TCC2P cards; therefore, you do not need to install software on the TCC2/TCC2P cards. When a new CTC software version is released, use the release-specific software upgrade document to upgrade the ONS 15454 software on the TCC2/TCC2P cards. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-1 Chapter 8 Cisco Transport Controller Operation 8.1.1 CTC Software Installed on the TCC2/TCC2P Card When you upgrade CTC software, the TCC2/TCC2P cards store the new CTC version as the protect CTC version. When you activate the new CTC software, the TCC2/TCC2P cards store the older CTC version as the protect CTC version, and the newer CTC release becomes the working version. You can view the software versions that are installed on an ONS 15454 by selecting the Maintenance > Software tabs in node view (Figure 8-1). Figure 8-1 CTC Software Versions, Node View Maintenance tab 159507 Software tab Cisco ONS 15454 Reference Manual, R8.5.x 8-2 78-18106-01 Chapter 8 Cisco Transport Controller Operation 8.1.2 CTC Software Installed on the PC or UNIX Workstation Select the Maintenance > Software tabs in network view to display the software versions installed on all the network nodes (Figure 8-2). Figure 8-2 CTC Software Versions, Network View 159505 Maintenance tab 8.1.2 CTC Software Installed on the PC or UNIX Workstation CTC software is downloaded from the TCC2/TCC2P cards and installed on your computer automatically after you connect to the ONS 15454 with a new software release for the first time. Downloading the CTC software files automatically ensures that your computer is running the same CTC software version as the TCC2/TCC2P cards you are accessing. The CTC files are stored in the temporary directory designated by your computer operating system. You can use the Delete CTC Cache button to remove files stored in the temporary directory. If the files are deleted, they download the next time you connect to an ONS 15454. Downloading the Java archive (JAR) files for CTC takes several minutes depending on the bandwidth of the connection between your workstation and the ONS 15454. For example, JAR files downloaded from a modem or a data communications channel (DCC) network link require more time than JAR files downloaded over a LAN connection. During network topology discovery, CTC polls each node in the network to determine which one contains the most recent version of the CTC software. If CTC discovers a node in the network that has a more recent version of the CTC software than the version you are currently running, CTC generates a message stating that a later version of the CTC has been found in the network and offers to install the CTC software upgrade JAR files. If you have network discovery disabled, CTC will not seek more recent versions of the software. Unreachable nodes are not included in the upgrade discovery. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-3 Chapter 8 Cisco Transport Controller Operation 8.2 CTC Installation Overview Note Upgrading the CTC software will overwrite your existing software. You must restart CTC after the upgrade is complete. 8.2 CTC Installation Overview To connect to an ONS 15454 using CTC, you enter the ONS 15454 IP address in the URL field of Netscape Navigator or Microsoft Internet Explorer. After connecting to an ONS 15454, the following occurs automatically: 1. A CTC launcher applet is downloaded from the TCC2/TCC2P card to your computer. 2. The launcher determines whether your computer has a CTC release matching the release on the ONS 15454 TCC2/TCC2P card. 3. If the computer does not have CTC installed, or if the installed release is older than the TCC2/TCC2P card’s version, the launcher downloads the CTC program files from the TCC2/TCC2P card. 4. The launcher starts CTC. The CTC session is separate from the web browser session, so the web browser is no longer needed. Always log into nodes having the latest software release. If you log into an ONS 15454 that is connected to ONS 15454s with older versions of CTC, or to Cisco ONS 15327s or Cisco ONS 15600s, CTC files are downloaded automatically to enable you to interact with those nodes. The CTC file download occurs only when necessary, such as during your first login. You cannot interact with nodes on the network that have a software version later than the node that you used to launch CTC. Each ONS 15454 can handle up to five concurrent CTC sessions. CTC performance can vary, depending on the volume of activity in each session, network bandwidth, and TCC2/TCC2P card load. Note You can also use TL1 commands to communicate with the Cisco ONS 15454 through VT100 terminals and VT100 emulation software, or you can telnet to an ONS 15454 using TL1 port 3083. Refer to the Cisco ONS SONET TL1 Command Guide for a comprehensive list of TL1 commands. 8.3 PC and UNIX Workstation Requirements To use CTC for the ONS 15454, your computer must have a web browser with the correct Java Runtime Environment (JRE) installed. The correct JRE for each CTC software release is included on the Cisco ONS 15454 software CD. If you are running multiple CTC software releases on a network, the JRE installed on the computer must be compatible with the different software releases. You can change the JRE version on the Preferences dialog box JRE tab. When you change the JRE version on the JRE tab, you must exit and restart CTC for the new JRE version to take effect. Table 8-1 shows JRE compatibility with ONS 15454 software releases. Cisco ONS 15454 Reference Manual, R8.5.x 8-4 78-18106-01 Chapter 8 Cisco Transport Controller Operation 8.3 PC and UNIX Workstation Requirements Table 8-1 JRE Compatibility ONS Software Release JRE 1.2.2 Compatible JRE 1.3 Compatible JRE 1.4 Compatible JRE 5.0 Compatible ONS 15454 Release 2.2.1 and earlier Yes No No No ONS 15454 Release 2.2.2 Yes Yes No No ONS 15454 Release 3.0 Yes Yes No No ONS 15454 Release 3.1 Yes Yes No No ONS 15454 Release 3.2 Yes Yes No No ONS 15454 Release 3.3 Yes Yes No No No Yes No No No Yes No No ONS 15454 Release 4.1 No Yes No No ONS 15454 Release 4.5 No Yes No No ONS 15454 Release 4.6 No Yes Yes No ONS 15454 Release 5.0 No No Yes No ONS 15454 Release 6.0 No No Yes No ONS 15454 Release 7.0 No No Yes Yes ONS 15454 Release 7.2 No No Yes Yes ONS 15454 Release 8.0 No No No Yes ONS 15454 Release 8.5 No No No Yes ONS 15454 Release 3.4 ONS 15454 Release 4.0 1 1. Software Releases 4.0 and later notify you if an older version of the JRE is running on your PC or UNIX workstation. Table 8-2 lists the requirements for PCs and UNIX workstations. In addition to the JRE, the Java plug-in is included on the ONS 15454 software CD. Table 8-2 Computer Requirements for CTC Area Requirements Notes Processor (PC only) Pentium 4 processor or equivalent A faster CPU is recommended if your workstation runs multiple applications or if CTC manages a network with a large number of nodes and circuits. RAM 512 MB RAM or more A minimum of 1 GB is recommended if your workstation runs multiple applications or if CTC manages a network with a large number of nodes and circuits. Hard drive 20 GB hard drive with 100MB of free space CTC application files are downloaded required from the TCC2/TCC2P to your computer. These files occupy around 100MB (250MB to be safer) or more space depending on the number of versions in the network. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-5 Chapter 8 Cisco Transport Controller Operation 8.3 PC and UNIX Workstation Requirements Table 8-2 Computer Requirements for CTC (continued) Area Requirements Operating System Notes • PC: Windows 98 (1st and 2nd editions), Check with the vendor for the latest patch/Service Pack level Windows ME, Windows NT 4.0 with Service Pack 6a, Windows 2000 with Service Pack 3, or Windows XP with Service Pack 1 • Workstation: Solaris versions 9 or 10 Java Runtime JRE 5.0 Environment JRE 5.0 is installed by the CTC Installation Wizard included on the Cisco ONS 15454 software CD. JRE 5.0 provide enhancements to CTC performance, especially for large networks with numerous circuits. Cisco recommends that you use JRE 5.0 for networks with Software R8.5 nodes. If CTC must be launched directly from nodes running software R7.0 or R7.2, Cisco recommends JRE 1.4.2 or JRE 5.0. If CTC must be launched directly from nodes running software R5.0 or R6.0, Cisco recommends JRE 1.4.2.If CTC must be launched directly from nodes running software earlier than R5.0, Cisco recommends JRE 1.3.1_02. Web browser • PC:Internet Explorer 6.x or Netscape 7.x • UNIX Workstation: Mozilla 1.7, Netscape 4.76, Netscape 7.x For the PC, use JRE 5.0 with any supported web browser. Cisco recommends Internet Explorer 6.x. For UNIX, use JRE 5.0 with Netscape 7.x or JRE 1.3.1_02 with Netscape 4.76. Netscape 4.76 or 7.x is available at the following site: http://channels.netscape.com/ns/brows ers/default.jsp Internet Explorer 6.x is available at the following site: http://www.microsoft.com Cable User-supplied CAT-5 straight-through cable — with RJ-45 connectors on each end to connect the computer to the ONS 15454 directly or through a LAN Cisco ONS 15454 Reference Manual, R8.5.x 8-6 78-18106-01 Chapter 8 Cisco Transport Controller Operation 8.4 ONS 15454 Connection 8.4 ONS 15454 Connection You can connect to the ONS 15454 in multiple ways. You can connect your PC directly the ONS 15454 (local craft connection) using the RJ-45 port on the TCC2/TCC2P card or the LAN pins on the backplane, connect your PC to a hub or switch that is connected to the ONS 15454, connect to the ONS 15454 through a LAN or modem, or establish TL1 connections from a PC or TL1 terminal. Table 8-3 lists the ONS 15454 connection methods and requirements. Table 8-3 Method ONS 15454 Connection Methods Description Requirements Local craft Refers to onsite network connections between the CTC computer and the ONS 15454 using one of the following: Corporate LAN If you do not use Dynamic Host Configuration Protocol (DHCP), you must change the computer IP address, subnet mask, and default router, or use automatic host detection. • The RJ-45 (LAN) port on the TCC2/TCC2P card • The LAN pins on the ONS 15454 backplane • A hub or switch to which the ONS 15454 is connected Refers to a connection to the ONS 15454 through a corporate or network operations center (NOC) LAN. • The ONS 15454 must be provisioned for LAN connectivity, including IP address, subnet mask, and default gateway. • The ONS 15454 must be physically connected to the corporate LAN. • The CTC computer must be connected to the corporate LAN that has connectivity to the ONS 15454. TL1 Refer to the Cisco ONS SONET TL1 Refers to a connection to the ONS 15454 using TL1 rather than CTC. TL1 sessions can Reference Guide. be started from CTC, or you can use a TL1 terminal. The physical connection can be a craft connection, corporate LAN, or a TL1 terminal. Remote Refers to a connection made to the ONS 15454 using a modem. • A modem must be connected to the ONS 15454. • The modem must be provisioned for the ONS 15454. To run CTC, the modem must be provisioned for Ethernet access. 8.5 CTC Login After you have installed CTC, you can log in to a node using your browser. To log in, you must type the node IP address in the URL window. The CTC Login window appears. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-7 Chapter 8 Cisco Transport Controller Operation 8.5.1 Legal Disclaimer The CTC Login window provides the following options to accelerate the login process. • The Disable Network Discovery option omits the discovery of nodes with data communications channel (DCC) connectivity. To access all nodes with DCC connectivity, make sure that Disable Network Discovery is not checked. If you have network discovery disabled, CTC will not poll the network for more recent versions of the software. (For more information about the automatic download of the latest CTC JAR files, see the “8.1.2 CTC Software Installed on the PC or UNIX Workstation” section on page 8-3.) • The Disable Circuit Management option omits the discovery of circuits. To view circuits immediately after logging in, make sure that Disable Circuit Management is not checked. However, if disabled, after you have logged in you can click the Circuits tab and CTC will give you the option to enable circuit management. These options are useful if you want to log in to a node to perform a single task, such as placing a card in or out of service, and do not want to wait while CTC discovers DCC connections and circuits. 8.5.1 Legal Disclaimer The CTC Login window currently displays the following warning message: “Warning: This system is restricted to authorized users for business purpose. Unauthorized access is a violation of the law. This service can be monitored for administrative and security reasons. By proceeding, you consent to this monitoring.” The ONS 15600 allows a user with Superuser privileges to modify the default login warning message and save it to a node using the Provisioning > Security > Legal Disclaimer > HTML tab. The login warning message field allows up to 250 characters of text (1600 characters total, including HTML markup). 8.5.2 Login Node Group Login node groups display nodes that have only an IP connection. After you are logged into CTC, you can create a login node group from the Edit > Preferences menu. Login groups appear in the Additional Nodes list on the Login window. For example, if you logged into Node 1, you would see Node 2 and Node 3 because they have DCC connectivity to Node 1. You would not see Nodes 4, 5, and 6 because DCC connections do not exist. To view all six nodes at once, you create a login node group with the IP addresses of Nodes 1, 4, 5, and 6. Those nodes, and all nodes optically connected to them, appear when you select the login group from the Additional Nodes list on the Login window the next time you log in. 8.6 CTC Window The CTC window appears after you log into an ONS 15454 (Figure 8-3). The window includes a menu bar, a toolbar, and a top and bottom pane. The top pane provides status information about the selected objects and a graphic of the current view. The bottom pane provides tabs and subtab to view ONS 15454 information and perform ONS 15454 provisioning and maintenance. From this window you can display three ONS 15454 views: network, node, and card. Cisco ONS 15454 Reference Manual, R8.5.x 8-8 78-18106-01 Chapter 8 Cisco Transport Controller Operation 8.6.1 Node View Figure 8-3 Node View (Default Login View) Menu bar Tool bar Status area Top pane Graphic area Tabs Subtabs 159506 Bottom pane Status bar 8.6.1 Node View Node view, shown in Figure 8-3, is the first view that appears after you log into an ONS 15454. The login node is the first node shown, and it is the “home view” for the session. Node view allows you to manage one ONS 15454 node. The status area shows the node name; IP address; session boot date and time; number of Critical (CR), Major (MJ), and Minor (MN) alarms; the name of the current logged-in user; and the security level of the user; software version; and the network element default setup. 8.6.1.1 CTC Card Colors The graphic area of the CTC window depicts the ONS 15454 shelf assembly. The colors of the cards in the graphic reflect the real-time status of the physical card and slot (Table 8-4). Table 8-4 Node View Card Colors Card Color Status Gray Slot is not provisioned; no card is installed. Violet Slot is provisioned; no card is installed. White Slot is provisioned; a functioning card is installed. Yellow Slot is provisioned; a Minor alarm condition exists. Orange Slot is provisioned; a Major alarm condition exists. Red Slot is provisioned; a Critical alarm exists. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-9 Chapter 8 Cisco Transport Controller Operation 8.6.1 Node View The wording on a card in node view shows the status of a card (Active, Standby, Loading, or Not Provisioned). Table 8-5 lists the card statuses. Table 8-5 Node View Card Statuses Card Status Description Sby Card is in standby mode. Act Card is active. NP Card is not present. Ldg Card is resetting. Mis Card is mismatched. The port color in both card and node view indicates the port service state. Table 8-6 lists the port colors and their service states. For more information about port service states, see Appendix B, “Administrative and Service States.” Table 8-6 Node View Card Port Colors and Service States Port Color Service State Description Blue OOS-MA,LPBK (Out-of-Service and Management, Loopback) Port is in a loopback state. On the card in node view, a line between ports indicates that the port is in terminal or facility loopback (see Figure 8-4 on page 8-11 and Figure 8-5 on page 8-11). Traffic is carried and alarm reporting is suppressed. Raised fault conditions, whether or not their alarms are reported, can be retrieved on the CTC Conditions tab or by using the TL1 RTRV-COND command. Blue OOS-MA,MT (Out-of-Service and Management, Maintenance) Port is out-of-service for maintenance. Traffic is carried and loopbacks are allowed. Alarm reporting is suppressed. Raised fault conditions, whether or not their alarms are reported, can be retrieved on the CTC Conditions tab or by using the TL1 RTRV-COND command. Use OOS-MA,MT for testing or to suppress alarms temporarily. Change the state to IS-NR, OOS-MA,DSBLD, or OOS-AU,AINS when testing is complete. Gray OOS-MA,DSBLD (Out-of-Service and Management, Disabled) The port is out-of-service and unable to carry traffic. Loopbacks are not allowed in this service state. Cisco ONS 15454 Reference Manual, R8.5.x 8-10 78-18106-01 Chapter 8 Cisco Transport Controller Operation 8.6.1 Node View Table 8-6 Node View Card Port Colors and Service States (continued) Port Color Service State Description Green IS-NR (In-Service and Normal) The port is fully operational and performing as provisioned. The port transmits a signal and displays alarms; loopbacks are not allowed. Violet OOS-AU,AINS (Out-of-Service and Autonomous, Automatic In-Service) The port is out-of-service, but traffic is carried. Alarm reporting is suppressed. The node monitors the ports for an error-free signal. After an error-free signal is detected, the port stays in OOS-AU,AINS state for the duration of the soak period. After the soak period ends, the port service state changes to IS-NR. Raised fault conditions, whether or not their alarms are reported, can be retrieved on the CTC Conditions tab or by using the TL1 RTRV-COND command. The AINS port will automatically transition to IS-NR when a signal is received for the length of time provisioned in the soak field. Figure 8-4 Terminal Loopback Indicator Figure 8-5 Facility Loopback Indicator 8.6.1.2 Node View Card Shortcuts If you move your mouse over cards in the graphic, popups display additional information about the card including the card type; the card status (active or standby); the type of alarm, such as Critical, Major, or Minor (if any); and the alarm profile used by the card. Right-click a card to reveal a shortcut menu, which you can use to open, reset, delete, or change a card. Right-click a slot to preprovision a card (that is, provision a slot before installing the card). 8.6.1.3 Node View Tabs Table 8-7 lists the tabs and subtabs available in the node view. Table 8-7 Node View Tabs and Subtabs Tab Description Alarms Lists current alarms (CR, MJ, MN) for the node — and updates them in real time. Conditions Displays a list of standing conditions on the node. Subtabs — Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-11 Chapter 8 Cisco Transport Controller Operation 8.6.2 Network View Table 8-7 Node View Tabs and Subtabs (continued) Tab Description History Provides a history of node alarms including date, Session, Shelf type, and severity of each alarm. The Session subtab displays alarms and events for the current session. The Node subtab displays alarms and events retrieved from a fixed-size log on the node. Circuits Creates, deletes, edits, and maps circuits and rolls. Circuits, Rolls Provisioning Provisions the ONS 15454 node. General, Ether Bridge, Network, OSI, BLSR, Protection, Security, SNMP, Comm Channels, Timing, Alarm Profiles, Cross-Connect, Defaults, WDM-ANS Inventory — Provides inventory information (part number, serial number, Common Language Equipment Identification [CLEI] codes) for cards installed in the node. Allows you to delete and reset cards, and change card service state. For more information on card service states, see Appendix B, “Administrative and Service States.” Maintenance Performs maintenance tasks for the node. Subtabs Database, Ether Bridge, Network, OSI, BLSR, Protection, Software, Cross-Connect, Overhead XConnect, Diagnostic, Timing, Audit, Test Access, DWDM 8.6.2 Network View Network view allows you to view and manage ONS 15454s that have DCC connections to the node that you logged into and any login node groups you have selected (Figure 8-6). Cisco ONS 15454 Reference Manual, R8.5.x 8-12 78-18106-01 Chapter 8 Cisco Transport Controller Operation 8.6.2 Network View Figure 8-6 Network in CTC Network View Icon color indicates node status Dots indicate selected node 96939 Bold letters indicate login node, asterisk indicates topology host Note Nodes with DCC connections to the login node do not appear if you checked the Disable Network Discovery check box in the Login dialog box. The graphic area displays a background image with colored ONS 15454 icons. A Superuser can set up the logical network view feature, which enables each user to see the same network view. Selecting a node or span in the graphic area displays information about the node and span in the status area. 8.6.2.1 Network View Tabs Table 8-8 lists the tabs and subtabs available in network view. Table 8-8 Network View Tabs and Subtabs Tab Description Subtabs Alarms Lists current alarms (CR, MJ, MN) for the network and updates them in real time. — Conditions Displays a list of standing conditions on the network. — History Provides a history of network alarms including — date, type, and severity of each alarm. Circuits Creates, deletes, edits, filters, and searches for Circuits, Rolls network circuits and rolls. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-13 Chapter 8 Cisco Transport Controller Operation 8.6.2 Network View Table 8-8 Network View Tabs and Subtabs (continued) Tab Description Subtabs Provisioning Provisions security, alarm profiles, bidirectional line switched rings (BLSRs), overhead circuits, server trails, and loads/manages a VLAN database Security, Alarm Profiles, BLSR, Overhead Circuits, Server Trails, VLAN DB Profile Maintenance Displays the working and protect software versions and allows software to be downloaded, retrieves Open Shortest Path First (OSPF) node information, and displays the list of automatic power control (APC) domains for a network Software, Diagnostic, APC 8.6.2.2 CTC Node Colors The color of a node in network view, shown in Table 8-9, indicates the node alarm status. Table 8-9 Node Status Shown in Network View Color Alarm Status Green No alarms Yellow Minor alarms Orange Major alarms Red Critical alarms Gray with Unknown# Node initializing for the first time (CTC displays Unknown# because CTC has not discovered the name of the node yet) 8.6.2.3 DCC Links The lines show DCC connections between the nodes (Table 8-10). DCC connections can be green (active) or gray (fail). The lines can also be solid (circuits can be routed through this link) or dashed (circuits cannot be routed through this link). Circuit provisioning uses active/routable links. Table 8-10 DCC Colors Indicating State in Network View Color and Line Style State Green and solid Active/Routable Green and dashed Active/Nonroutable Gray and solid Failed/Routable Gray and dashed Failed/Nonroutable Cisco ONS 15454 Reference Manual, R8.5.x 8-14 78-18106-01 Chapter 8 Cisco Transport Controller Operation 8.6.3 Card View 8.6.2.4 Link Consolidation CTC provides the ability to consolidate the DCC, general communications channel (GCC), optical transport section (OTS), provisionable patchcord (PPC), and server trail links shown in the network view. Link consolidation allows you to condense multiple inter-nodal links into a single link. The link consolidation sorts links by class; for example, all DCC links are consolidated together.You can access individual links within consolidated links using the right-click shortcut menu. Each link has an associated icon (Table 8-11). Table 8-11 Icon Link Icons Description DCC icon GCC icon OTS icon PPC icon Server Trail icon Note Link consolidation is only available on non-detailed maps. Non-detailed maps display nodes in icon form instead of detailed form, meaning the nodes appear as rectangles with ports on the sides. Refer to the Cisco ONS 15454 Procedure Guide for more information about consolidated links. 8.6.3 Card View The card view provides information about individual ONS 15454 cards. Use this window to perform card-specific maintenance and provisioning (Figure 8-7). A graphic showing the ports on the card is shown in the graphic area. The status area displays the node name, slot, number of alarms, card type, equipment type, and the card status (active or standby), card service state if the card is present, and port service state (described in Table 8-6 on page 8-10). The information that appears and the actions you can perform depend on the card. For more information about card service states, see Appendix B, “Administrative and Service States.” Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-15 Chapter 8 Cisco Transport Controller Operation 8.6.3 Card View Figure 8-7 CTC Card View Showing a DS1 Card 159504 Card identification and status Note CTC provides a card view for all ONS 15454 cards except the TCC2, TCC2P, XCVT, XC10G, and XC-VXC-10G cards. Provisioning for these common control cards occurs at the node view; therefore, no card view is necessary. Use the card view tabs and subtabs shown in Table 8-12 to provision and manage the ONS 15454. The subtabs, fields, and information shown under each tab depend on the card type selected. The Performance tab is not available for the Alarm Interface Controller-International (AIC-I) cards. Table 8-12 Card View Tabs and Subtabs Tab Description Alarms Lists current alarms (CR, MJ, MN) for the card — and updates them in real time. Conditions Displays a list of standing conditions on the card. — History Provides a history of card alarms including date, object, port, and severity of each alarm. Session (displays alarms and events for the current session), Card (displays alarms and events retrieved from a fixed-size log on the card) Circuits Creates, deletes, edits, and search circuits and Circuits, Rolls rolls. Subtabs Cisco ONS 15454 Reference Manual, R8.5.x 8-16 78-18106-01 Chapter 8 Cisco Transport Controller Operation 8.6.4 Print or Export CTC Data Table 8-12 Card View Tabs and Subtabs (continued) Tab Description Subtabs Provisioning Provisions an ONS 15454 card. DS-N and OC-N cards: Line, Line Thresholds (different threshold options are available for electrical and optical cards), Elect Path Thresholds, SONET Thresholds, Alarm Profiles Ethernet cards (subtabs depend on the card type): Line, Line Thresholds, Electrical Path Thresholds, SONET Thresholds, Port, RMON Thresholds, VLAN, Card, Alarm Profiles Maintenance Performs maintenance tasks for the card. DS-N and OC-N cards: Loopback, ALS, Info, Protection, Path Trace, Bandwidth, AINS Soak Ethernet cards (subtabs depend on the card type): Path Trace, Loopback, Allocation, AINS Soak, Ether Port Soak, RPR Span Soak Performance Performs performance monitoring for the card. DS-N and OC-N cards: no subtabs Ethernet cards: Statistics, Utilization, History Inventory Displays an Inventory screen of the ports (TXP — and MXP cards only). 8.6.4 Print or Export CTC Data You can use the File > Print or File > Export options to print or export CTC provisioning information for record keeping or troubleshooting. The functions can be performed in card, node, or network views. The File > Print function sends the data to a local or network printer. File > Export exports the data to a file where it can be imported into other computer applications, such as spreadsheets and database management programs. Whether you choose to print or export data, you can choose from the following options: • Entire frame—Prints or exports the entire CTC window including the graphical view of the card, node, or network. This option is available for all windows. • Tabbed view—Prints or exports the lower half of the CTC window containing tabs and data. The printout includes the selected tab (on top) and the data shown in the tab window. For example, if you print the History window Tabbed view, you print only history items appearing in the window. This option is available for all windows. • Table Contents—Prints or exports CTC data in table format without graphical representations of shelves, cards, or tabs. The Table Contents option prints all the data contained in a table with the same column headings. For example, if you print the History window Table Contents view, you print all data included in the table whether or not items appear in the window. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-17 Chapter 8 Cisco Transport Controller Operation 8.7 Using the CTC Launcher Application to Manage Multiple ONS Nodes The Table Contents option does not apply to all windows; for a list of windows that do not support print or export, see the Cisco ONS 15454 Procedure Guide. 8.7 Using the CTC Launcher Application to Manage Multiple ONS Nodes The CTC Launcher application is an executable file, StartCTC.exe, that is provided on Software Release 8.5 CDs for Cisco ONS products. You can use CTC Launcher to log into multiple ONS nodes that are running CTC Software Release 3.3 or higher, without using a web browser. CTC Launcher provides two connection options. The first option is used to connect to ONS network elements (NEs) that have an IP connection to the CTC computer. The second option is used to connect to ONS NEs that reside behind third party, OSI-based gateway network elements (GNEs). For this option, CTC Launcher creates a TL1 tunnel to transport the TCP traffic through the OSI-based GNE. The TL1 tunnel transports the TCP traffic to and from ONS ENEs through the OSI-based GNE. TL1 tunnels are similar to the existing static IP-over-CLNS tunnels, GRE and Cisco IP, that can be created at ONS NEs using CTC. (Refer to the Cisco ONS product documentation for information about static IP-over-CLNS tunnels.) However, unlike the static IP-over-CLNS tunnels, TL1 tunnels require no provisioning at the ONS ENE, the third-party GNE, or DCN routers. All provisioning occurs at the CTC computer when the CTC Launcher is started. Figure 8-8 shows examples of two static IP-over-CLNS tunnels. A static Cisco IP tunnel is created from ENE 1 through other vendor GNE 1 to a DCN router, and a static GRE tunnel is created from ONS ENE 2 to the other vender, GNE 2. For both static tunnels, provisioning is required on the ONS ENEs. In addition, a Cisco IP tunnel must be provisioned on the DCN router and a GRE tunnel provisioned on GNE 2. Cisco ONS 15454 Reference Manual, R8.5.x 8-18 78-18106-01 Chapter 8 Cisco Transport Controller Operation 8.7 Using the CTC Launcher Application to Manage Multiple ONS Nodes Figure 8-8 Static IP-Over-CLNS Tunnels Central office Other vendor GNE 1 ONS ENE 1 OSI/DCC Tunnel provisioning IP/DCC IP+ OSI IP-over-CLNS tunnel Tunnel provisioning IP DCN CTC Other vendor GNE 2 ONS ENE 2 IP/DCC OSI/DCC IP-over-CLNS Tunnel Tunnel tunnel provisioning provisioning 140174 IP Figure 8-9 shows the same network using TL1 tunnels. Tunnel provisioning occurs at the CTC computer when the tunnel is created with the CTC Launcher. No provisioning is needed at ONS NEs, GNEs or routers. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-19 Chapter 8 Cisco Transport Controller Operation 8.7 Using the CTC Launcher Application to Manage Multiple ONS Nodes Figure 8-9 TL1 Tunnels Central office Other vendor GNE 1 ONS ENE 1 OSI/DCC IP/DCC IP + OSI Tunnel provisioning TL1 tunnel IP DCN CTC IP Other vendor GNE 2 ONS ENE 2 OSI/DCC IP/DCC 140175 TL1 tunnel TL1 tunnels provide several advantages over static IP-over-CLNS tunnels. Because tunnel provisioning is needed only at the CTC computer, they are faster to set up. Because they use TL1 for TCP transport, they are more secure. TL1 tunnels also provide better flow control. On the other hand, IP over CLNS tunnels require less overhead and usually provide a slight performance edge over TL1 Tunnels (depending on network conditions). TL1 tunnels do not support all IP applications such as SNMP and RADIUS Authentication. Table 8-13 shows a comparison between the two types of tunnels. Table 8-13 TL1 and Static IP-Over-CLNS Tunnels Comparison Category Static IP-Over-CLNS TL1 Tunnel Comments Setup Complex Simple Requires provisioning at ONS NE, GNE, and DCN routers. For TL1 tunnels, provisioning is needed at CTC computer. Performance Best Average to good Static tunnels generally provide better performance than TL1 tunnels, depending on TL1 encoding used. LV+Binary provides the best performance. Other encoding will produce slightly slower TL1 tunnel performance. Support all IP applications Yes No TL1 tunnels do not support SNMP or RADIUS Server IP applications. ITU Standard Yes No Only the static IP-over-CLNS tunnels meet ITU standards. TL1 tunnels are new. Tunnel traffic control Good Very good Both tunnel types provide good traffic control Security setup Complex No setup needed Static IP-over-CLNS tunnels require careful planning. Because TL1 tunnels are carried by TL1, no security provisioning is needed. Cisco ONS 15454 Reference Manual, R8.5.x 8-20 78-18106-01 Chapter 8 Cisco Transport Controller Operation 8.8 TCC2/TCC2P Card Reset Table 8-13 TL1 and Static IP-Over-CLNS Tunnels Comparison (continued) Static IP-Over-CLNS Category TL1 Tunnel Comments Potential to breach DCN Possible from DCC using IP. Not possible A potential exists to breach a DCN from a DCC using IP. This potential does not exist for TL1 tunnels. IP route management Expensive Automatic For static IP-over-CLNS tunnels, route changes require manual provisioning at network routers, GNEs, and ENEs. For TL1 tunnels, route changes are automatic. Flow control Weak Strong TL1 tunnels provide the best flow control. Bandwidth sharing among multiple applications Weak Best — Tunnel lifecycle Fixed CTC session TL1 tunnels are terminated when the CTC session ends. Static IP-over-CLNS tunnels exist until they are deleted in CTC. TL1 tunnel specifications and general capabilities include: • Each tunnel generally supports between six to eight ENEs, depending on the number of tunnels at the ENE. • Each CTC session can support up to 32 tunnels. • The TL1 tunnel database is stored locally in the CTC Preferences file. • Automatic tunnel reconnection when the tunnel goes down. • Each ONS NE can support at least 16 concurrent tunnels. 8.8 TCC2/TCC2P Card Reset You can reset the ONS 15454 TCC2/TCC2P card by using CTC (a soft reset) or by physically reseating a TCC2/TCC2P card (a hard reset). A soft reset reboots the TCC2/TCC2P card and reloads the operating system and the application software. Additionally, a hard reset temporarily removes power from the TCC2/TCC2P card and clears all buffer memory. You can apply a soft reset from CTC to either an active or standby TCC2/TCC2P card without affecting traffic. If you need to perform a hard reset on an active TCC2/TCC2P card, put the TCC2/TCC2P card into standby mode first by performing a soft reset. Note When a CTC reset is performed on an active TCC2/TCC2P card, the AIC-I cards go through an initialization process and also reset because AIC-I cards are controlled by the active TCC2/TCC2P. 8.9 TCC2/TCC2P Card Database When dual TCC2/TCC2P cards are installed in the ONS 15454, each TCC2/TCC2P card hosts a separate database; therefore, the protect card database is available if the database on the working TCC2/TCC2P fails. You can also store a backup version of the database on the workstation running CTC. This Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 8-21 Chapter 8 Cisco Transport Controller Operation 8.10 Software Revert operation should be part of a regular ONS 15454 maintenance program at approximately weekly intervals, and should also be completed when preparing an ONS 15454 for a pending natural disaster, such as a flood or fire. A database backup may be restored in two ways, partial or complete. A partial database restore operation restores only the provisioning data. A complete database restore operation restores both system and provisioning data. For more information on restoring a database, refer to the Cisco ONS 15454 Procedure Guide. Note The following parameters are not backed up and restored: node name, IP address, mask and gateway, and Internet Inter-ORB Protocol (IIOP) port. If you change the node name and then restore a backed up database with a different node name, the circuits map to the new node name. Cisco recommends keeping a record of the old and new node names. Note To avoid a node IP and secure IP ending up in the same domain after restoring a database, ensure that the node IP stored in the database differs in domain from that of the node in repeater mode. Also, after restoring a database, ensure that the node IP and secure IP differ in domain. 8.10 Software Revert When you click the Activate button after a software upgrade, the TCC2/TCC2P copies the current working database and saves it in a reserved location in the TCC2/TCC2P flash memory. If you later need to revert to the original working software load from the protect software load, the saved database installs automatically. You do not need to restore the database manually or recreate circuits. Note The TCC2/TCC2P card does not carry any software earlier than Software R4.0. You will not be able to revert to a software release earlier than Software R4.0 with TCC2/TCC2P cards installed. The revert feature is useful if a maintenance window closes while you are upgrading CTC software. You can revert to the protect software load without losing traffic. When the next maintenance window opens, complete the upgrade and activate the new software load. Circuits created and provisioning done after a software load is activated (upgraded to a higher software release) will be lost with a revert. The database configuration at the time of activation is reinstated after a revert. This does not apply to maintenance reverts (for example, 4.6.2 to 4.6.1), because maintenance releases use the same database. To perform a supported (non-service-affecting) revert from Software R8.5, the release you want to revert to must have been working at the time you first activated Software R8.5 on that node. Because a supported revert automatically restores the node configuration at the time of the previous activation, any configuration changes made after activation will be lost when you revert the software. Downloading Release 8.5 a second time after you have activated the new load ensures that no actual revert to a previous load can take place (the TCC2/TCC2P card will reset, but will not be traffic affecting and will not change your database). Cisco ONS 15454 Reference Manual, R8.5.x 8-22 78-18106-01 CH A P T E R 9 Security This chapter provides information about Cisco ONS 15454 users and security. To provision security, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 9.1 User IDs and Security Levels, page 9-1 • 9.2 User Privileges and Policies, page 9-1 • 9.3 Audit Trail, page 9-8 • 9.4 RADIUS Security, page 9-9 9.1 User IDs and Security Levels The CISCO15 user ID is provided with the ONS 15454 for initial login to the node, but this user ID is not supplied in the prompt when you sign into Cisco Transport Controller (CTC). This ID can be used to set up other ONS 15454 user IDs. You can have up to 500 user IDs on one ONS 15454. Each CTC or Transaction Language One (TL1) user can be assigned one of the following security levels: • Retrieve—Users can retrieve and view CTC information but cannot set or modify parameters. • Maintenance—Users can access only the ONS 15454 maintenance options. • Provisioning—Users can access provisioning and maintenance options. • Superuser—Users can perform all of the functions of the other security levels as well as set names, passwords, and security levels for other users. See Table 9-3 on page 9-7 for idle user timeout information for each security level. By default, multiple concurrent user ID sessions are permitted on the node; that is, multiple users can log into a node using the same user ID. However, you can provision the node to allow only a single login per user ID and prevent concurrent logins for all users. 9.2 User Privileges and Policies This section lists user privileges for each CTC action and describes the security policies available to Superusers for provisioning. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 9-1 Chapter 9 Security 9.2.1 User Privileges by CTC Action 9.2.1 User Privileges by CTC Action Table 9-1 shows the actions that each user privilege level can perform in node view. Table 9-1 ONS 15454 Security Levels—Node View CTC Tab Subtab [Subtab]:Actions Retrieve Maintenance Provisioning Superuser Alarms — Synchronize/Filter/Delete Cleared Alarms X1 X X X Conditions — Retrieve/Filter X X X X History Session Filter X X X X Shelf Retrieve/Filter X X X X — X X Circuits Circuits 2 Create/Delete — Edit/Filter/Search X X X X Complete/ Force Valid Signal/ Finish — — X X General: Edit — — Partial3 X Multishelf Config: Edit — — — — Power Monitor: Edit — — X X EtherBridge Spanning trees: Edit — — X X Network General: Edit — — — X Static Routing: Create/Edit/Delete — — X X OSPF: Create/Edit/Delete — — X X RIP: Create/Edit/Delete — — X X Proxy: Create/Edit/Delete — — — X Firewall: Create/Edit/Delete — — — X Main Setup: Edit — — — X TARP: Config: Edit — — — X TARP: Static TDC: Add/Edit/Delete — — X X TARP: MAT: Add/Edit/Remove — — X X Routers: Setup: Edit — — — X Routers: Subnets: Edit/Enable/Disable — — X X Tunnels: Create/Edit/Delete — — X X Create/Edit/Delete/Upgrade — — X X Ring Map/Squelch Table/RIP Table X X X X Create/Edit/Delete — — X X Rolls Provisioning General OSI BLSR Protection Cisco ONS 15454 Reference Manual, R8.5.x 9-2 78-18106-01 Chapter 9 Security 9.2.1 User Privileges by CTC Action Table 9-1 CTC Tab ONS 15454 Security Levels—Node View (continued) Subtab [Subtab]:Actions Retrieve Maintenance Provisioning Superuser Security Users: Create/Delete/Clear Security Intrusion Alarm — — — X Users: Edit Same user Same user Same user All users Active Logins: View/Logout/ Retrieve Last Activity Time — — — X Policy: Edit/View — (Prevent superuser disable - NE default) — — X Access: Edit/View — — — X RADIUS Server: Create/Edit/Delete/Move Up/ Move Down/View — — — X Legal Disclaimer: Edit — — — X Create/Edit/Delete — — X X Browse trap destinations X X X X SDCC: Create/Edit/Delete — — X X LDCC: Create/Edit/Delete — — X X GCC: Create/Edit/Delete — — X X OSC: OSC Terminations: Create/Edit/Delete — — X X PPC: Create/Edit/Delete — — X X LMP: General/TE Links/Data Links X X X X LMP: Control Channels — — — X General: Edit — — X X BITS Facilities: Edit — — X X Alarm Behavior: Edit — — X X Alarm Profile Editor: Store/Delete4 — — X X Alarm Profile Editor: X New/Load/Compare/Available/ Usage X X X Cross-Connect Edit — — X X Defaults Edit/Import — — — X Reset/Export X X X X SNMP Comm Channels Timing Alarm Profiles Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 9-3 Chapter 9 Security 9.2.1 User Privileges by CTC Action Table 9-1 CTC Tab Inventory ONS 15454 Security Levels—Node View (continued) Subtab [Subtab]:Actions Retrieve Maintenance Provisioning Superuser WDM-ANS Provisioning: Edit — — — X Provisioning: Reset X X X X Internal Patchcords: Create/Edit/Delete/Commit/ Default Patchcords — — X X Port Status: Launch ANS — — — X Node Setup X X X X Optical Side: Create/Edit/Delete X X X X Delete — — X X Reset — X X X Backup — X X X Restore — — — X Spanning Trees X X X X MAC Table: Retrieve X X X X MAC Table: Clear/Clear All — X X X Trunk Utilization: Refresh X X X X Circuits: Refresh X X X X Routing Table: Retrieve X X X X RIP Routing Table: Retrieve X X X X IS-IS RIB: Refresh X X X X ES-IS RIB: Refresh X X X X TDC: TID to NSAP/Flush Dynamic Entries — X X X TDC: Refresh X X X X BLSR Edit/Reset — X X X Protection Switch/Lock out/Lockon/ Clear/ Unlock — X X X Software Download/Cancel — X X X Activate/Revert — — — X Cards: Switch/Lock/Unlock — X X X Resource Usage: Delete — — X X Overhead XConnect View X X X X Diagnostic Retrieve Tech Support Log — — X X Lamp Test — X X X Source: Edit — X X X Report: View/Refresh X X X X — Maintenance Database EtherBridge Network OSI Cross-Connect Timing Cisco ONS 15454 Reference Manual, R8.5.x 9-4 78-18106-01 Chapter 9 Security 9.2.1 User Privileges by CTC Action Table 9-1 CTC Tab ONS 15454 Security Levels—Node View (continued) Subtab [Subtab]:Actions Retrieve Maintenance Provisioning Superuser Audit Retrieve — — — X Archive — — X X Test Access View X X X X DWDM APC: Run/Disable/Refresh — X X X WDM Span Check: Edit/Retrieve Span Loss values/Reset X X X X ROADM Power Monitoring: Refresh X X X X PP-MESH Internal Patchcord: Refresh X X X X Install Without Metro Planner: Retrieve Installation values X X X X All Facilities: Mark/Refresh X X X X 1. X indicates that the user can perform the actions. 2. — indicates that the privilege to perform an action is not available to the user. 3. Provisioner user cannot change node name, contact, location, or AIS-V insertion on STS-1 signal degrade (SD) parameters. 4. The action buttons in the subtab are active for all users, but the actions can be completely performed only by the users with the required security levels. Table 9-2 shows the actions that each user privilege level can perform in network view. Table 9-2 CTC Tab ONS 15454 Security Levels—Network View Subtab [Subtab]: Actions Retrieve Alarms — Synchronize/Filter/Delete cleared alarms X Conditions — Retrieve/Filter X History — Filter X Circuits Circuits Rolls 1 2 Maintenance Provisioning Superuser X X X X X X X X X — X X Create/Edit/Delete — Filter/Search X X X X Complete, Force Valid Signal, — Finish — X X Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 9-5 Chapter 9 Security 9.2.2 Security Policies Table 9-2 CTC Tab ONS 15454 Security Levels—Network View (continued) Subtab [Subtab]: Actions Retrieve Maintenance Provisioning Superuser Users: Create/Delete — — — X Users: Edit Same user Same user Same user All users Active logins: — Logout/Retrieve Last Activity Time — — X Policy: Change — — — X — — X X New/Load/Compare/ Available/Usage X X X X BLSR Create/Delete/Edit/Upgrade — — X X Overhead Circuits Create/Delete/Edit/Merge — — X X Search X X X X Provisionable Patchcords (PPC) Create/Edit/Delete — — X X Server Trails Create/Edit/Delete — — X X VLAN DB Profile Load/Store/Merge/Circuits X X X X Download/Cancel — X X X Diagnostic OSPF Node Information: Retrieve/Clear X X X X APC Run APC/Disable APC — — — X Refresh X X X X Provisioning Security Alarm Profiles Maintenance Software Store/Delete 3 1. X indicates that the user can perform the actions. 2. — indicates that the privilege to perform an action is not available to the user. 3. The action buttons in the subtab are active for all users, but the actions can be completely performed only by the users with the required security levels. 9.2.2 Security Policies Users with Superuser security privileges can provision security policies on the ONS 15454. These security policies include idle user timeouts, password changes, password aging, and user lockout parameters. In addition, a Superuser can access the ONS 15454 through the TCC2/TCC2P RJ-45 port, the backplane LAN connection, or both. If enabled in the NE defaults, superusers can be configured to override the inactive user timeout interval. 9.2.2.1 Superuser Privileges for Provisioning Users Superusers can grant permission to Provisioning users to retrieve audit logs, restore databases, clear performance monitoring (PM) parameters, activate software loads, and revert software loads. These privileges can only be set using CTC network element (NE) defaults, except the PM clearing privilege, which can be granted to a Provisioning user using the CTC Provisioning> Security > Access tabs. For more information about setting up Superuser privileges, refer to the Cisco ONS 15454 Procedure Guide. Cisco ONS 15454 Reference Manual, R8.5.x 9-6 78-18106-01 Chapter 9 Security 9.2.2 Security Policies 9.2.2.2 Idle User Timeout Each ONS 15454 CTC or TL1 user can be idle during his or her login session for a specified amount of time before the CTC window is locked. The lockouts prevent unauthorized users from making changes. Higher-level users have shorter default idle periods and lower-level users have longer or unlimited default idle periods, as shown in Table 9-3. The user idle period can be modified by a Superuser; refer to the Cisco ONS 15454 Procedure Guide for instructions. Table 9-3 ONS 15454 Default User Idle Times Security Level Idle Time Superuser 15 minutes Provisioning 30 minutes Maintenance 60 minutes Retrieve Unlimited 9.2.2.3 User Password, Login, and Access Policies Superusers can view real-time lists of users who are logged into CTC or TL1 by node. Superusers can also provision the following password, login, and node access policies: • Password length, expiration and reuse—Superusers can configure the password length using NE defaults. The password length, by default, is set to a minimum of six and a maximum of 20 characters. You can configure the default values in CTC node view with the Provisioning > Defaults > Node > security > password Complexity tabs. The minimum length can be set to eight, ten or twelve characters, and the maximum length to 80 characters. The password must be a combination of alphanumeric (a-z, A-Z, 0-9) and special (+, #,%) characters, where at least two characters are nonalphabetic and at least one character is a special character. Superusers can specify when users must change and when they can reuse their passwords. • Locking out and disabling users—Superusers can provision the number of invalid logins that are allowed before locking out users and the length of time before inactive users are disabled. • Node access and user sessions—Superusers can limit the number of CTC sessions a user login can have to just one session. Superusers can also prohibit access to the ONS 15454 using the LAN or TCC2/TCC2P RJ-45 connections. In addition, a Superuser can select secure shell (SSH) instead of Telnet at the CTC Provisioning > Security > Access tabs. SSH is a terminal-remote host Internet protocol that uses encrypted links. It provides authentication and secure communication over unsecure channels. Port 22 is the default port and cannot be changed. Port 22 is only for VxWorks access. To use secure TL-1 you need a secure shell program and you need to use port 4083. Superuser can also configure EMS and TL1 access states to secure and non-secure modes. Note The superuser cannot modify the privilege level of an active user. The CTC displays a warning message when the superuser attempts to modify the privilege level of an active user. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 9-7 Chapter 9 Security 9.3 Audit Trail 9.2.2.4 Secure Access Secure access is based on SSH and SSL protocols. Secure access can be enabled for EMS (applicable to CTC). When access is set to secure, CTC provides enhanced SFTP and SSH security when communicating with the node. For more information on how to enable EMS secure access, refer Cisco ONS 15454 Procedure Guide for instructions. 9.3 Audit Trail The Cisco ONS 15454 maintains a Telcordia GR-839-CORE-compliant audit trail log that resides on the TCC2/TCC2P card. Audit trails are useful for maintaining security, recovering lost transactions, and enforcing accountability. Accountability refers to tracing user activities; that is, associating a process or action with a specific user. The audit trail log shows who has accessed the system and what operations were performed during a given period of time. The log includes authorized Cisco support logins and logouts using the operating system command line interface (CLI), CTC, and TL1; the log also includes FTP actions, circuit creation/deletion, and user/system generated actions. Event monitoring is also recorded in the audit log. An event is defined as the change in status of an network element. External events, internal events, attribute changes, and software upload/download activities are recorded in the audit trail. To view the audit trail log, refer to the Cisco ONS 15454 Procedure Guide. You can access the audit trail logs from any management interface (CTC, CTM, TL1). The audit trail is stored in persistent memory and is not corrupted by processor switches, resets, or upgrades. However, if you remove both TCC2/TCC2P cards, the audit trail log is lost. 9.3.1 Audit Trail Log Entries Table 9-4 contains the columns listed in Audit Trail window. Table 9-4 Audit Trail Window Columns Heading Explanation Date Date when the action occurred Num Incrementing count of actions User User ID that initiated the action P/F Pass/Fail (whether or not the action was executed) Operation Action that was taken Audit trail records capture the following activities: • User—Name of the user performing the action • Host—Host from where the activity is logged • Device ID—IP address of the device involved in the activity • Application—Name of the application involved in the activity • Task—Name of the task involved in the activity (view a dialog box, apply configuration, etc.) Cisco ONS 15454 Reference Manual, R8.5.x 9-8 78-18106-01 Chapter 9 Security 9.3.2 Audit Trail Capacities • Connection Mode—Telnet, Console, SNMP • Category—Type of change (Hardware, Software, Configuration) • Status—Status of the user action (Read, Initial, Successful, Timeout, Failed) • Time—Time of change • Message Type—Whether the event is Success/Failure type • Message Details—Description of the change 9.3.2 Audit Trail Capacities The ONS 15454 is able to store 640 log entries. When this limit is reached, the oldest entries are overwritten with new events. When the log server is 80 percent full, an AUD-LOG-LOW condition is raised and logged (by way of CORBA/CTC). When the log server reaches the maximum capacity of 640 entries and begins overwriting records that were not archived, an AUD-LOG-LOSS condition is raised and logged. This event indicates that audit trail records have been lost. Until you off-load the file, this event will not occur a second time regardless of the amount of entries that are overwritten by incoming data. To export the audit trail log, refer to the Cisco ONS 15454 Procedure Guide. 9.4 RADIUS Security Users with Superuser security privileges can configure nodes to use Remote Authentication Dial In User Service (RADIUS) authentication. Cisco Systems uses a strategy known as authentication, authorization, and accounting (AAA) for verifying the identity of, granting access to, and tracking the actions of remote users. 9.4.1 RADIUS Authentication RADIUS is a system of distributed security that secures remote access to networks and network services against unauthorized access. RADIUS comprises three components: • A protocol with a frame format that utilizes User Datagram Protocol (UDP)/IP • A server • A client The server runs on a central computer, typically at a customer site, while the clients reside in the dial-up access servers and can be distributed throughout the network. An ONS 15454 node operates as a client of RADIUS. The client is responsible for passing user information to designated RADIUS servers, and then acting on the response that is returned. RADIUS servers are responsible for receiving user connection requests, authenticating the user, and returning all configuration information necessary for the client to deliver service to the user. The RADIUS servers can act as proxy clients to other kinds of authentication servers. Transactions between the RADIUS client and server are authenticated through the use of a shared secret, which is never sent over the network. In addition, any user passwords are sent encrypted between the client and RADIUS server. This eliminates the possibility that someone monitoring an unsecured network could determine a user's password. Refer to the Cisco ONS 15454 Procedure Guide for detailed instructions for implementing RADIUS authentication. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 9-9 Chapter 9 Security 9.4.2 Shared Secrets 9.4.2 Shared Secrets A shared secret is a text string that serves as a password between: • A RADIUS client and RADIUS server • A RADIUS client and a RADIUS proxy • A RADIUS proxy and a RADIUS server For a configuration that uses a RADIUS client, a RADIUS proxy, and a RADIUS server, the shared secret that is used between the RADIUS client and the RADIUS proxy can be different from the shared secret used between the RADIUS proxy and the RADIUS server. Shared secrets are used to verify that RADIUS messages, with the exception of the Access-Request message, are sent by a RADIUS-enabled device that is configured with the same shared secret. Shared secrets also verify that the RADIUS message has not been modified in transit (message integrity). The shared secret is also used to encrypt some RADIUS attributes, such as User-Password and Tunnel-Password. When creating and using a shared secret: • Use the same case-sensitive shared secret on both RADIUS devices. • Use a different shared secret for each RADIUS server-RADIUS client pair. • To ensure a random shared secret, generate a random sequence at least 22 characters long. • You can use any standard alphanumeric and special characters. • You can use a shared secret of up to 128 characters in length. To protect your server and your RADIUS clients from brute force attacks, use long shared secrets (more than 22 characters). • Make the shared secret a random sequence of letters, numbers, and punctuation and change it often to protect your server and your RADIUS clients from dictionary attacks. Shared secrets should contain characters from each of the three groups listed in Table 9-5. Table 9-5 Shared Secret Character Groups Group Examples Letters (uppercase and lowercase) A, B, C, D and a, b, c, d Numerals 0, 1, 2, 3 Symbols (all characters not defined as letters or numerals) Exclamation point (!), asterisk (*), colon (:) The stronger your shared secret, the more secure are the attributes (for example, those used for passwords and encryption keys) that are encrypted with it. An example of a strong shared secret is 8d#>9fq4bV)H7%a3-zE13sW$hIa32M#m Timing > Report tabs show current timing information for an ONS 15454, including the timing mode, clock state and status, switch type, and reference data. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 10-1 Chapter 10 Timing 10.2 Network Timing Caution Note Mixed timing allows you to select both external and line timing sources. However, Cisco does not recommend its use because it can create timing loops. Use this mode with caution. Only one port can be used for timing related provisioning per line card. 10.2 Network Timing Figure 10-1 shows an ONS 15454 network timing setup example. Node 1 is set to external timing. Two timing references are set to BITS. These are Stratum 1 timing sources wired to the BITS input pins on the Node 1 backplane. The third reference is set to internal clock. The BITS output pins on the backplane of Node 3 are used to provide timing to outside equipment, such as a digital access line multiplexer. In the example, Slots 5 and 6 contain the trunk (span) cards. Timing at Nodes 2, 3, and 4 is set to line, and the timing references are set to the trunk cards based on distance from the BITS source. Reference 1 is set to the trunk card closest to the BITS source. At Node 2, Reference 1 is Slot 5 because it is connected to Node 1. At Node 4, Reference 1 is set to Slot 6 because it is connected to Node 1. At Node 3, Reference 1 could be either trunk card because they are an equal distance from Node 1. Cisco ONS 15454 Reference Manual, R8.5.x 10-2 78-18106-01 Chapter 10 Timing 10.3 Synchronization Status Messaging Figure 10-1 ONS 15454 Timing Example BITS1 source BITS2 source Node 1 Timing External Ref 1: BITS1 Ref 2: BITS2 Ref 3: Internal (ST3) Slot 5 Slot 6 Slot 5 Slot 5 Slot 6 Slot 6 Node 2 Timing Line Ref 1: Slot 5 Ref 2: Slot 6 Ref 3: Internal (ST3) Slot 5 BITS1 BITS2 out out Third party equipment Node 3 Timing Line Ref 1: Slot 5 Ref 2: Slot 6 Ref 3: Internal (ST3) 34726 Node 4 Timing Line Ref 1: Slot 6 Ref 2: Slot 5 Ref 3: Internal (ST3) Slot 6 10.3 Synchronization Status Messaging Synchronization status messaging (SSM) is a SONET and SDH protocol that communicates information about the quality of the timing source. SSM messages are transported as follows: • If SSM is carried over an optical line, for both SONET and SDH the SSM is transported in the S1 byte. • If SSM is carried over an electrical line: – For SDH, the SSM is transported in the Sa bit of E1. – For SONET, the SSM is transported in the outband loop code. The SSM messages enable SONET and SDH devices to select the highest quality timing reference automatically and to avoid timing loops. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 10-3 Chapter 10 Timing 10.3.1 SONET SSM Messages 10.3.1 SONET SSM Messages SSM messages are either Generation 1 or Generation 2. Generation 1 is the first and most widely deployed SSM message set. Generation 2 is a newer version. If you enable SONET SSM for the ONS 15454, consult your timing reference documentation to determine which message set to use. Table 10-1 and Table 10-2 show the SONET Generation 1 and Generation 2 message sets. Table 10-1 SONET SSM Generation 1 Message Set Message Quality Description PRS 1 Primary reference source—Stratum 1 STU 2 Synchronization traceability unknown ST2 3 Stratum 2 ST3 4 Stratum 3 SMC 5 SONET minimum clock ST4 6 Stratum 4 DUS 7 Do not use for timing synchronization RES — Reserved; quality level set by user Table 10-2 SONET SSM Generation 2 Message Set Message Quality Description PRS 1 Primary reference source—Stratum 1 STU 2 Synchronization traceability unknown ST2 3 Stratum 2 TNC 4 Transit node clock ST3E 5 Stratum 3E ST3 6 Stratum 3 SMC 7 SONET minimum clock ST4 8 Stratum 4 DUS 9 Do not use for timing synchronization RES — Reserved; quality level set by user 10.3.2 SDH SSM Messages If you enable SDH SSM for the ONS 15454, consult your timing reference documentation to determine which message set to use. Table 10-3 shows the SDH SSM messages. Table 10-3 SDH SSM Messages Message Quality Description G811 1 Primary reference clock STU 2 Sync traceability unknown Cisco ONS 15454 Reference Manual, R8.5.x 10-4 78-18106-01 Chapter 10 Timing 10.3.2 SDH SSM Messages Table 10-3 SDH SSM Messages (continued) Message Quality Description G812T 3 Transit node clock traceable G812L 4 Local node clock traceable SETS 5 Synchronous equipment DUS 6 Do not use for timing synchronization Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 10-5 Chapter 10 Timing 10.3.2 SDH SSM Messages Cisco ONS 15454 Reference Manual, R8.5.x 10-6 78-18106-01 CH A P T E R 11 Circuits and Tunnels Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This chapter explains Cisco ONS 15454 synchronous transport signal (STS), virtual tributary (VT), and virtual concatenated (VCAT) circuits and VT, data communications channel (DCC), and IP-encapsulated tunnels. To provision circuits and tunnels, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 11.1 Overview, page 11-2 • 11.2 Circuit Properties, page 11-2 • 11.3 Cross-Connect Card Bandwidth, page 11-12 • 11.4 Portless Transmux, page 11-15 • 11.5 DCC Tunnels, page 11-16 • 11.6 SDH Tunneling, page 11-18 • 11.7 Multiple Destinations for Unidirectional Circuits, page 11-18 • 11.8 Monitor Circuits, page 11-18 • 11.9 Path ProtectionCircuits, page 11-19 • 11.10 BLSR Protection Channel Access Circuits, page 11-21 • 11.11 BLSR STS and VT Squelch Tables, page 11-22 • 11.12 IEEE 802.17 Resilient Packet Ring Circuit Display, page 11-23 • 11.13 Section and Path Trace, page 11-24 • 11.14 Path Signal Label, C2 Byte, page 11-25 • 11.15 Automatic Circuit Routing, page 11-27 • 11.16 Manual Circuit Routing, page 11-29 • 11.17 Constraint-Based Circuit Routing, page 11-33 • 11.18 Virtual Concatenated Circuits, page 11-34 • 11.19 Bridge and Roll, page 11-40 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-1 Chapter 11 Circuits and Tunnels 11.1 Overview • 11.20 Merged Circuits, page 11-46 • 11.21 Reconfigured Circuits, page 11-47 • 11.22 VLAN Management, page 11-47 • 11.23 Server Trails, page 11-47 11.1 Overview You can create circuits across and within ONS 15454 nodes and assign different attributes to circuits. For example, you can: • Create one-way, two-way (bidirectional), or broadcast circuits. • Assign user-defined names to circuits. • Assign different circuit sizes. • Automatically or manually route circuits. • Automatically create multiple circuits with autoranging. VT tunnels do not use autoranging. • Provide full protection to the circuit path. • Provide only protected sources and destinations for circuits. • Define a secondary circuit source or destination that allows you to interoperate an ONS 15454 path protection configuration with third-party equipment path protection configurations. • Set path protection circuits as revertive or nonrevertive. You can provision circuits at either of the following points: • Before cards are installed. The ONS 15454 allows you to provision slots and circuits before installing the traffic cards. • After you preprovision the Small Form-factor Pluggables (SFPs) (also called provisionable port modules [PPMs]). • After cards and SFPs are installed and ports are in service. Circuits do not actually carry traffic until the cards and SFPs are installed and the ports are In-Service and Normal (IS-NR); Out-of-Service and Autonomous, Automatic In-Service (OO-AU,AINS); or Out-of-Service and Management, Maintenance (OOS-MA,MT). Circuits carry traffic as soon as the signal is received. 11.2 Circuit Properties The ONS 15454 Cisco Transport Controller (CTC) Circuits window, which appears in network, node, and card view, is where you can view information about circuits. The Circuits window (Figure 11-1) provides the following information: • Name—The name of the circuit. The circuit name can be manually assigned or automatically generated. • Type—The circuit types are STS (STS circuit), VT (VT circuit), VTT (VT tunnel), VAP (VT aggregation point), OCHNC (dense wavelength division multiplexing [DWDM] optical channel network connection; refer to the Cisco ONS 15454 DWDM Procedure Guide), STS-V (STS VCAT circuit), or VT-V (VT VCAT circuit). Cisco ONS 15454 Reference Manual, R8.5.x 11-2 78-18106-01 Chapter 11 Circuits and Tunnels 11.2 Circuit Properties • Size—The circuit size. VT circuits are 1.5. STS circuit sizes are 1, 3c, 6c, 9c, 12c, 24c, 36c, 48c, and 192c. OCHNC sizes are Equipped non specific, Multi-rate, 2.5 Gbps No FEC (forward error correction), 2.5 Gbps FEC, 10 Gbps No FEC, and 10 Gbps FEC (OCHNC is DWDM only; refer to the Cisco ONS 15454 DWDM ProcedureGuide). VCAT circuits are VT1.5-nv, STS-1-nv, STS-3c-nv, and STS-12c-nv, where n is the number of members. For time slot availability on concatenated STSs, see the “11.2.1 Concatenated STS Time Slot Assignments” section on page 11-4. • OCHNC Wlen—For OCHNCs, the wavelength provisioned for the optical channel network connection. For more information, refer to the Cisco ONS 15454 DWDM Procedure Guide. • Direction—The circuit direction, either two-way or one-way. • OCHNC Dir—For OCHNCs, the direction of the optical channel network connection, either east to west or west to east. For more information, refer to the Cisco ONS 15454 DWDM Procedure Guide. • Protection—The type of circuit protection. See the “11.2.4 Circuit Protection Types” section on page 11-9 for a list of protection types. • Status—The circuit status. See the “11.2.2 Circuit Status” section on page 11-6. • Source—The circuit source in the format: node/slot/port “port name”/STS/VT. (The port name appears in quotes.) Node and slot always appear; port “port name”/STS/VT might appear, depending on the source card, circuit type, and whether a name is assigned to the port. For the OC192-XFP and MRC-12 cards, the port appears as port pluggable module (PPM)-port. If the circuit size is a concatenated size (3c, 6c, 12c, etc.), STSs used in the circuit are indicated by an ellipsis, for example, S7..9, (STSs 7, 8, and 9) or S10..12 (STS 10, 11, and 12). • Destination—The circuit destination in the same format as the circuit source. • # of VLANS—The number of VLANs used by an Ethernet circuit. • # of Spans—The number of internode links that constitute the circuit. Right-clicking the column shows a shortcut menu from which you can choose Span Details to show or hide circuit span detail. For each node in the span, the span detail shows the node/slot (card type)/port/STS/VT. • State—The circuit state. See the “11.2.3 Circuit States” section on page 11-7. The Filter button allows you to filter the circuits in network, node, or card view based on circuit name, size, type, direction, and other attributes. In addition, you can export the Circuit window data in HTML, comma-separated values (CSV), or tab-separated values (TSV) format using the Export command from the File menu. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-3 Chapter 11 Circuits and Tunnels 11.2.1 Concatenated STS Time Slot Assignments Figure 11-1 ONS 15454 Circuit Window in Network View 11.2.1 Concatenated STS Time Slot Assignments Table 11-1 shows the available time slot assignments for concatenated STSs when using CTC to provision circuits. Table 11-1 STS Mapping Using CTC Starting STS STS-3c STS-6c STS-9c STS-12c STS-18c STS-24c STS-36c STS-48c STS-192c 1 Yes Yes Yes Yes Yes Yes Yes Yes Yes 4 Yes Yes Yes No Yes Yes Yes No No 7 Yes Yes No No Yes Yes Yes No No 10 Yes No Yes No Yes Yes Yes No No 13 Yes Yes Yes Yes Yes Yes Yes No No 16 Yes Yes Yes No Yes Yes No No No 19 Yes Yes Yes No Yes Yes No No No 22 Yes No No No Yes Yes No No No 25 Yes Yes Yes Yes Yes Yes No No No 28 Yes Yes Yes No Yes No No No No 31 Yes Yes No No Yes No No No No 34 Yes No No No No No No No No 37 Yes Yes Yes Yes Yes No Yes No No Cisco ONS 15454 Reference Manual, R8.5.x 11-4 78-18106-01 Chapter 11 Circuits and Tunnels 11.2.1 Concatenated STS Time Slot Assignments Table 11-1 STS Mapping Using CTC (continued) Starting STS STS-3c STS-6c STS-9c STS-12c STS-18c STS-24c STS-36c STS-48c STS-192c 40 Yes Yes Yes No No No No No No 43 Yes Yes No No No No No No No 46 Yes No Yes No No No No No No 49 Yes Yes Yes Yes Yes Yes Yes Yes No 52 Yes Yes Yes No Yes Yes Yes No No 55 Yes Yes Yes No Yes Yes Yes No No 58 Yes No No No Yes Yes Yes No No 61 Yes Yes Yes Yes Yes Yes Yes No No 64 Yes Yes Yes No Yes Yes No No No 67 Yes Yes No No Yes Yes No No No 70 Yes No No No Yes Yes No No No 73 Yes Yes Yes Yes Yes Yes Yes No No 76 Yes Yes Yes No Yes No No No No 79 Yes Yes No No Yes No No No No 82 Yes No Yes No No No No No No 85 Yes Yes Yes Yes No No No No No 88 Yes Yes Yes No No No No No No 91 Yes Yes Yes No Yes No No No No 94 Yes No No No No No No No No 97 Yes Yes Yes Yes Yes Yes Yes Yes No 100 Yes Yes Yes No Yes Yes Yes No No 103 Yes Yes No No Yes Yes Yes No No 106 Yes No No No Yes Yes Yes No No 109 Yes Yes Yes Yes Yes Yes Yes No No 112 Yes Yes Yes No Yes Yes No No No 115 Yes Yes No No Yes Yes No No No 118 Yes No Yes No Yes Yes No No No 121 Yes Yes Yes Yes Yes Yes No No No 124 Yes Yes Yes No Yes No No No No 127 Yes Yes Yes No Yes No No No No 130 Yes No No No No No No No No 133 Yes Yes Yes Yes No No No No No 136 Yes Yes Yes No No No No No No 139 Yes Yes No No No No No No No 142 Yes No No No No No No No No Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-5 Chapter 11 Circuits and Tunnels 11.2.2 Circuit Status Table 11-1 STS Mapping Using CTC (continued) Starting STS STS-3c STS-6c STS-9c STS-12c STS-18c STS-24c STS-36c STS-48c STS-192c 145 Yes Yes Yes Yes Yes Yes Yes Yes No 148 Yes Yes Yes No Yes Yes Yes No No 151 Yes Yes No No Yes Yes Yes No No 154 Yes No Yes No Yes Yes Yes No No 157 Yes Yes Yes Yes Yes Yes Yes No No 160 Yes Yes Yes No Yes Yes No No No 163 Yes Yes Yes No Yes Yes No No No 166 Yes No No No Yes Yes No No No 169 Yes Yes Yes Yes Yes Yes No No No 172 Yes Yes Yes No Yes No No No No 175 Yes Yes No No Yes No No No No 178 Yes No No No No No No No No 181 Yes Yes Yes Yes Yes No No No No 184 Yes Yes Yes No Yes No No No No 187 Yes Yes No No Yes No No No No 190 Yes No No No Yes No No No No 11.2.2 Circuit Status The circuit statuses that appear in the Circuit window Status column are generated by CTC based on conditions along the circuit path. Table 11-2 shows the statuses that can appear in the Status column. Table 11-2 ONS 15454 Circuit Status Status Definition/Activity CREATING CTC is creating a circuit. DISCOVERED CTC created a circuit. All components are in place and a complete path exists from circuit source to destination. DELETING CTC is deleting a circuit. Cisco ONS 15454 Reference Manual, R8.5.x 11-6 78-18106-01 Chapter 11 Circuits and Tunnels 11.2.3 Circuit States Table 11-2 ONS 15454 Circuit Status (continued) Status Definition/Activity PARTIAL A CTC-created circuit is missing a cross-connect or network span, a complete path from source to destinations does not exist, or an alarm interface panel (AIP) change occurred on one of the circuit nodes and the circuit is in need of repair. (AIPs store the node MAC address.) In CTC, circuits are represented using cross-connects and network spans. If a network span is missing from a circuit, the circuit status is PARTIAL. However, a PARTIAL status does not necessarily mean a circuit traffic failure has occurred, because traffic might flow on a protect path. Network spans are in one of two states: up or down. On CTC circuit and network maps, up spans appear as green lines, and down spans appear as gray lines. If a failure occurs on a network span during a CTC session, the span remains on the network map but its color changes to gray to indicate that the span is down. If you restart your CTC session while the failure is active, the new CTC session cannot discover the span and its span line does not appear on the network map. Subsequently, circuits routed on a network span that goes down appear as DISCOVERED during the current CTC session, but appear as PARTIAL to users who log in after the span failure. DISCOVERED_TL1 A TL1-created circuit or a TL1-like, CTC-created circuit is complete. A complete path from source to destinations exists. PARTIAL_TL1 A TL1-created circuit or a TL1-like, CTC-created circuit is missing a cross-connect or circuit span (network link), and a complete path from source to destinations does not exist. CONVERSION_PENDING An existing circuit in a topology upgrade is set to this state. The circuit returns to the DISCOVERED state once the topology upgrade is complete. For more information about topology upgrades, see Chapter 12, “SONET Topologies and Upgrades.” PENDING_MERGE Any new circuits created to represent an alternate path in a topology upgrade are set to this status to indicate that it is a temporary circuit. These circuits can be deleted if a topology upgrade fails. For more information about topology upgrades, see Chapter 12, “SONET Topologies and Upgrades.” DROP_PENDING A circuit is set to this status when a new circuit drop is being added. ROLL_PENDING A circuit roll is awaiting completion or cancellation. 11.2.3 Circuit States The circuit service state is an aggregate of the cross-connect states within the circuit. • If all cross-connects in a circuit are in the In-Service and Normal (IS-NR) service state, the circuit service state is In-Service (IS). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-7 Chapter 11 Circuits and Tunnels 11.2.3 Circuit States • If all cross-connects in a circuit are in an Out-of-Service (OOS) service state, such as Out-of-Service and Management, Maintenance (OOS-MA,MT); Out-of-Service and Management, Disabled (OOS-MA,DSBLD); or Out-of-Service and Autonomous, Automatic In-Service (OOS-AU,AINS) service state, the circuit service state is Out-of-Service (OOS). • PARTIAL is appended to the OOS circuit service state when circuit cross-connects state are mixed and not all in IS-NR. The OOS-PARTIAL state can occur during automatic or manual transitions between states. For example, OOS-PARTIAL appears if you assign the IS,AINS administrative state to a circuit with DS-1 or DS3XM cards as the source or destination. Some cross-connects transition to the IS-NR service state, while others transition to OOS-AU,AINS. OOS-PARTIAL can appear during a manual transition caused by an abnormal event such as a CTC crash or communication error, or if one of the cross-connects could not be changed. Refer to the Cisco ONS 15454 Troubleshooting Guide for troubleshooting procedures. The OOS-PARTIAL circuit state does not apply to OCHNC circuit types. You can assign a state to circuit cross-connects at two points: Note • During circuit creation, you can set the state in the Create Circuit wizard. • After circuit creation, you can change a circuit state in the Edit Circuit window or from the Tools > Circuits > Set Circuit State menu. After you have created an initial circuit in a CTC session, the subsequent circuit states default to the circuit state of the initial circuit, regardless of which nodes in the network the circuits traverse or the node.ckt.state default setting. During circuit creation, you can apply a service state to the drop ports in a circuit. You cannot transition a drop port from the IS-NR service state to the OOS-MA,DSBLD service state; you must first put the port in the OOS-MA,MT state before changing it to the OOS-MA,DSBLD state. For more information about port service state transitions, see Appendix B, “Administrative and Service States.” Circuits do not use the soak timer, but ports do. The soak period is the amount of time that the port remains in the OOS-AU,AINS service state after a signal is continuously received. When the cross-connects in a circuit are in the OOS-AU,AINS service state, the ONS 15454 monitors the cross-connects for an error-free signal. It changes the state of the circuit from OOS to IS or to OOS-PARTIAL as each cross-connect assigned to the circuit path is completed. This allows you to provision a circuit using TL1, verify its path continuity, and prepare the port to go into service when it receives an error-free signal for the time specified in the port soak timer. Two common examples of state changes you see when provisioning circuits using CTC are: • When assigning the IS,AINS administrative state to cross-connects in VT circuits and VT tunnels, the source and destination ports on the VT circuits remain in the OOS-AU,AINS service state until an alarm-free signal is received for the duration of the soak timer. When the soak timer expires and an alarm-free signal is found, the VT source port and destination port service states change to IS-NR and the circuit service state becomes IS. • When assigning the IS,AINS administrative state to cross-connects in STS circuits, the circuit source and destination ports transition to the OOS-AU,AINS service state. When an alarm-free signal is received, the source and destination ports remain OOS-AU,AINS for the duration of the soak timer. After the port soak timer expires, STS source and destination ports change to IS-NR and the circuit service state changes to IS. To find the remaining port soak time, choose the Maintenance > AINS Soak tabs in card view and click the Retrieve button. If the port is in the OOS-AU,AINS state and has a good signal, the Time Until IS column shows the soak count down status. If the port is OOS-AU,AINS and has a bad signal, the Time Until IS column indicates that the signal is bad. You must click the Retrieve button to obtain the latest time value. Cisco ONS 15454 Reference Manual, R8.5.x 11-8 78-18106-01 Chapter 11 Circuits and Tunnels 11.2.4 Circuit Protection Types Note Although ML-Series cards do not use the Telcordia GR-1093-CORE state model, you can also set a soak timer for ML-Series cards ports. The soak period is the amount of time that the ML-Series port remains in the Down state after an error-free signal is continuously received before changing to the Up state. To find the remaining port soak time, choose the Maintenance > Ether/POS Port Soak tabs in ML-Series card view and click the Retrieve button. For more information about port and cross-connect states, see Appendix B, “Administrative and Service States.” 11.2.4 Circuit Protection Types The Protection column in the Circuit window shows the card (line) and SONET topology (path) protection used for the entire circuit path. Table 11-3 shows the protection type indicators that appear in this column. Table 11-3 Circuit Protection Types Protection Type Description 1+1 The circuit is protected by a 1+1 protection group. 2F BLSR The circuit is protected by a two-fiber BLSR. 4F BLSR The circuit is protected by a four-fiber BLSR. 2F-PCA The circuit is routed on a protection channel access (PCA) path on a two-fiber BLSR. PCA circuits are unprotected. 4F-PCA The circuit is routed on a PCA path on a four-fiber BLSR. PCA circuits are unprotected. BLSR The circuit is protected by a both a two-fiber and a four-fiber BLSR. DRI The circuit is protected by a dual-ring interconnection (DRI). N/A A circuit with connections on the same node is not protected. PCA The circuit is routed on a PCA path on both two-fiber and four-fiber BLSRs. PCA circuits are unprotected. Protected The circuit is protected by diverse SONET topologies, for example, a BLSR and a path protection configuration, or a path protection configuration and 1+1 protection. Unknown A circuit has a source and destination on different nodes and communication is down between the nodes. This protection type appears if not all circuit components are known. Unprot (black) A circuit with a source and destination on different nodes is not protected. Unprot (red) A circuit created as a fully protected circuit is no longer protected due to a system change, such as removal of a BLSR or 1+1 protection group. Path Protection The circuit is protected by a path protection. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-9 Chapter 11 Circuits and Tunnels 11.2.5 Circuit Information in the Edit Circuit Window Table 11-3 Circuit Protection Types (continued) Protection Type Description SPLITTER The circuit is protected by the protect transponder (TXPP_MR_2.5G) splitter protection. For splitter information, refer to the Cisco ONS 15454 DWDM Procedure Guide. Y-Cable The circuit is protected by a transponder or muxponder card Y-cable protection group. For more information, refer to the Cisco ONS 15454 DWDM Procedure Guide. 11.2.5 Circuit Information in the Edit Circuit Window You can edit a selected circuit using the Edit button on the Circuits window. The tabs that appear depend on the circuit chosen: • General—Displays general circuit information and allows you to edit the circuit name. • Drops—Allows you to add a drop to a unidirectional circuit. For more information, see the “11.7 Multiple Destinations for Unidirectional Circuits” section on page 11-18. • Monitors—Displays possible monitor sources and allows you to create a monitor circuit. For more information, see the “11.8 Monitor Circuits” section on page 11-18. • Path Protection Selectors—Allows you to change path protection selectors. For more information, see the “11.9 Path ProtectionCircuits” section on page 11-19. • Path Protection Switch Counts—Allows you to change path protection switch protection paths. For more information, see the “11.9 Path ProtectionCircuits” section on page 11-19. • State—Allows you to edit cross-connect service states. • Merge—Allows you to merge aligned circuits. For more information, see the “11.20 Merged Circuits” section on page 11-46. Using the Export command from the File menu, you can export data from the Path Protection Selectors, Path Protection Switch Counts, State, and Merge tabs in HTML, comma-separated values (CSV), or tab-separated values (TSV) format. The Show Detailed Map checkbox in the Edit Circuit window updates the graphical view of the circuit to show more detailed routing information, such as: • Circuit direction (unidirectional/bidirectional) • The nodes, STSs, and VTs through which a circuit passes, including slots and port numbers • The circuit source and destination points • Open Shortest Path First (OSPF) area IDs • Link protection (path protection, unprotected, BLSR, 1+1) and bandwidth (OC-N) • Provisionable patchcords between two cards on the same node or different nodes For BLSRs, the detailed map shows the number of BLSR fibers and the BLSR ring ID. For path protection configurations, the map shows the active and standby paths from circuit source to destination, and it also shows the working and protect paths. Selectors appear as pentagons on the detailed circuit map. The map indicates nodes set up as DRI nodes. For VCAT circuits, the detailed map is not available for an entire VCAT circuit. However, you can view the detailed map to see the circuit route for each individual member. You can also view alarms and states on the circuit map, including: Cisco ONS 15454 Reference Manual, R8.5.x 11-10 78-18106-01 Chapter 11 Circuits and Tunnels 11.2.5 Circuit Information in the Edit Circuit Window • Alarm states of nodes on the circuit route • Number of alarms on each node organized by severity • Port service states on the circuit route • Alarm state/color of most severe alarm on port • Loopbacks • Path trace states • Path selector states By default, the working path is indicated by a green, bidirectional arrow, and the protect path is indicated by a purple, bidirectional arrow. Source and destination ports are shown as circles with an S and D. Port states are indicated by colors, shown in Table 11-4. Table 11-4 Port State Color Indicators Port Color Service State Green IS-NR Gray OOS-MA,DSBLD Violet OOS-AU,AINS Blue (Cyan) OOS-MA,MT In detailed view, a notation within or by the squares or selector pentagons indicates switches and loopbacks, including: • F = Force switch • M = Manual switch • L = Lockout switch • Arrow = Facility (outward) or terminal (inward) loopback Move the mouse cursor over nodes, ports, and spans to see tooltips with information including the number of alarms on a node (organized by severity), the port service state, and the protection topology. Right-click a node, port, or span on the detailed circuit map to initiate certain circuit actions: • Right-click a unidirectional circuit destination node to add a drop to the circuit. • Right-click a port containing a path-trace-capable card to initiate the path trace. • Right-click a path protection span to change the state of the path selectors in the path protection circuit. Figure 11-2 shows a circuit routed on a two-fiber BLSR. A port is shown in terminal loopback. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-11 Chapter 11 Circuits and Tunnels 11.3 Cross-Connect Card Bandwidth Figure 11-2 BLSR Circuit Displayed on the Detailed Circuit Map 11.3 Cross-Connect Card Bandwidth The ONS 15454 XCVT, XC10G, and XC-VXC-10G cross-connect cards perform port-to-port, time-division multiplexing (TDM). XCVT, XC10G, and XC-VXC-10G cards perform STS, VT2 (XC-VXC-10G only), and VT1.5 multiplexing. The STS matrix on the XCVT cross-connect card has a capacity for 288 STS terminations, and the XC10G and XC-VXC-10G cards each have a capacity for 1152 STS terminations. Because each STS circuit requires a minimum of two terminations, one for ingress and one for egress, the XCVT card has a capacity for 144 STS circuits, while the XC10G and XC-VXC-10G cards have a capacity for 576 STS circuits. However, this capacity is reduced at path protection and 1+1 nodes because three STS terminations are required at circuit source and destination nodes and four terminations are required at 1+1 circuit pass-through nodes. Path protection pass-through nodes only require two STS terminations. The XCVT and XC10G cards perform VT1.5 multiplexing through 24 logical STS ports on the XCVT or XC10G VT matrix, and the XC-VXC-10G card performs VT1.5 and VT2 multiplexing through 96 logical STS ports on the XC-VXC-10G VT matrix. Each logical STS port can carry 28 VT1.5s or 21 VT2s. Subsequently, the VT matrix on the XCVT or XC10G has capacity for 672 VT1.5 terminations, or 336 VT1.5 circuits. The VT matrix on the XC-VXC-10G has capacity for 2688 VT1.5 terminations (1344 VT1.5 bidirectional circuits) or 2016 VT2 terminations (1008 VT2 bidirectional circuits). Every circuit requires two terminations, one for ingress and one for egress. However, this capacity is only achievable if: • Every STS port on the VT matrix carries 28 VT1.5s or 21 VT2s. • The node is in a BLSR or 1+1 protection scheme. Cisco ONS 15454 Reference Manual, R8.5.x 11-12 78-18106-01 Chapter 11 Circuits and Tunnels 11.3 Cross-Connect Card Bandwidth For example, if you create a VT1.5 circuit from an STS-1 on a drop card, two VT matrix STS ports are used, as shown in Figure 11-3. If you create a second VT1.5 circuit from the same STS port on the drop card, no additional logical STS ports are used on the VT matrix. In fact, you can create up to 28 VT1.5 circuits using the same STS-1 port. However, if the next VT1.5 circuit originates on a different STS, an additional pair of STS ports on the VT matrix is used, as shown in Figure 11-4. If you continued to create VT1.5 circuits on different EC-1 STSs and mapped each to an unused outbound STS, the VT matrix capacity would be reached after you created 12 VT1.5 circuits in the case of the XCVT or XC10G cards, or 48 VT1.5 circuits in the case of the XC-VXC-10G card. Figure 11-3 One VT1.5 Circuit on One STS VT1.5 circuit #1 on STS-1 1 VT1.5 used on STS-1 27 VT1.5s available on STS-1 XCVT/XC10G Matrices Source STS Matrix Drop EC-1 2 STSs total used 22 STSs available OC-12 VT1.5 Matrix VT1.5 circuit #1 on STS-1 1 VT1.5 used on STS-1 27 VT1.5s available on STS-1 XC-VXC-10G Matrices Source STS Matrix Drop EC-1 2 STSs total used 94 STSs available OC-192 STS VT1.5 134344 VT1.5 Matrix Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-13 Chapter 11 Circuits and Tunnels 11.3 Cross-Connect Card Bandwidth Figure 11-4 Two VT1.5 Circuits in a BLSR VT1.5 circuit #1 on STS-1 1 VT1.5 used on STS-1 27 VT1.5s available on STS-1 XCVT/XC10G Matrices Source STS Matrix Drop EC-1 4 STSs total used 20 STSs available OC-12 VT1.5 Matrix VT1.5 circuit #2 on STS-2 1 VT1.5 used on STS-2 27 VT1.5s available on STS-2 VT1.5 circuit #1 on STS-1 1 VT1.5 used on STS-1 27 VT1.5s available on STS-1 XC-VXC-10G Matrices Source STS Matrix Drop EC-1 4 STSs total used 92 STSs available OC-192 VT1.5 circuit #2 on STS-2 1 VT1.5 used on STS-2 27 VT1.5s available on STS-2 Note STS VT1.5 134345 VT1.5 Matrix Circuits with DS1-14 and DS1N-14 circuit sources or destinations use one STS port on the VT matrix. Because you can only create 14 VT1.5 circuits from the DS-1 cards, 14 VT1.5s are unused on the VT matrix. VT matrix capacity is also affected by SONET protection topology and node position within the circuit path. Matrix usage is slightly higher for path protection nodes than BLSR and 1+1 nodes. Circuits use two VT matrix ports at pass-through nodes if VT tunnels and aggregation points are not used. If the circuit is routed on a VT tunnel or an aggregation point, no VT matrix resources are used. Table 11-5 shows basic STS port usage rates for VT 1.5 circuits. Cisco ONS 15454 Reference Manual, R8.5.x 11-14 78-18106-01 Chapter 11 Circuits and Tunnels 11.4 Portless Transmux Table 11-5 VT Matrix Port Usage for One VT1.5 Circuit Node Type No Protection BLSR Path Protection 1+1 Circuit source or destination node 2 2 3 2 Circuit pass-through node without VT tunnel 2 2 2 2 Circuit pass-through node with VT tunnel 0 0 0 0 Cross-connect card resources can be viewed on the Maintenance > Cross-Connect > Resource Usage tab. This tab shows: • STS-1 Matrix—The percent of STS matrix resources that are used. 288 STSs are available on XCVT cards; 1152 are available on XC10G and XC-VXC-10G cards. • VT Matrix Ports—The percent of the VT matrix ports (logical STS ports) that are used. 24 ports are available on XCVT and XC10G cards. 96 ports are available on the XC-VXC-10G card. The VT Port Matrix Detail shows the percent of each VT matrix port that is used. • VT Matrix—The percent of the total VT matrix terminations that are used. There are 672 terminations for the XCVT and XC10G cards. 672 is the number of logical STS VT matrix ports (24) multiplied by the number of VT1.5s per port (28). There are 2688 terminations for the XC-VXC-10G card. 2688 is the number of logical STS VT matrix ports (96) multiplied by the number of VT1.5s per port (28). To maximize resources on the cross-connect card VT matrix, keep the following points in mind as you provision circuits: • Use all 28 VT1.5s on a given port or STS before moving to the next port or STS. • Try to use EC-1, DS3XM, or OC-N cards as the VT1.5 circuit source and destination. VT1.5 circuits with DS-1-14 or DS1N-14 sources or destinations use a full port on the VT matrix even though only 14 VT1.5 circuits can be created. • Use VT tunnels and VT aggregation points to reduce VT matrix utilization. VT tunnels allow VT1.5 circuits to bypass the VT matrix on pass-through nodes. They are cross-connected as STSs and only go through the STS matrix. VT aggregation points allow multiple VT1.5 circuits to be aggregated onto a single STS to bypass the VT matrix at the aggregation node. 11.4 Portless Transmux The DS3XM-12 card provides a portless transmux interface to change DS-3s into VT1.5s. For XCVT drop slots, the DS3XM-12 card provides a maximum of 6 portless transmux interfaces; for XCVT trunk slots and XC10G or XC-VXC-10G slots, the DS3XM-12 card provides a maximum of 12 portless transmux interfaces. If two ports are configured as portless transmux, CTC allows you to create a DS3/STS1 circuit using one of these ports as the circuit end point. You can create separate DS1/VT1.5 circuits (up to 28) using the other port in this portless transmux pair. When creating a circuit through the DS3XM-12 card, the portless pair blocks the mapped physical port(s); CTC does not display a blocked physical port in the source or destination drop-down list during circuit creation. Table 11-6 lists the portless transmux mapping for XCVT drop ports. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-15 Chapter 11 Circuits and Tunnels 11.5 DCC Tunnels Table 11-6 Portless Transmux Mapping for XCVT Drop Ports Physical Port Portless Port Pair 1, 2 13, 14 3, 4 15, 16 5, 6 17, 18 7, 8 19, 20 9, 10 21, 22 11, 12 23, 24 Table 11-7 lists the portless transmux for XCVT trunk ports and for XC10G or XC-VXC-10G any-slot ports. Table 11-7 Portless Transmux Mapping for XCVT Trunk and XC10G/XC-VXC-10G Any-Slot Ports Physical Port Portless Port Pair 1 13, 14 2 25, 26 3 15, 16 4 27, 28 5 17, 18 6 29, 30 7 19, 20 8 31, 32 9 21, 22 10 33, 34 11 23, 24 12 35, 36 11.5 DCC Tunnels SONET provides four DCCs for network element (NE) operation, administration, maintenance, and provisioning (OAM&P): one on the SONET Section layer (DCC1) and three on the SONET Line layer (DCC2, DCC3, and DCC4). The ONS 15454 uses the Section DCC (SDCC) for ONS 15454 management and provisioning. An SDCC and Line DCC (LDCC) each provide 192 Kbps of bandwidth per channel. The aggregate bandwidth of the three LDCCs is 576 Kbps. When multiple DCC channels exist between two neighboring nodes, the ONS 15454 balances traffic over the existing DCC channels using a load balancing algorithm. This algorithm chooses a DCC for packet transport by considering packet size and DCC utilization. You can tunnel third-party SONET equipment across ONS 15454 networks using one of two tunneling methods: a traditional DCC tunnel or an IP-encapsulated tunnel. Cisco ONS 15454 Reference Manual, R8.5.x 11-16 78-18106-01 Chapter 11 Circuits and Tunnels 11.5.1 Traditional DCC Tunnels 11.5.1 Traditional DCC Tunnels In traditional DCC tunnels, you can use the three LDCCs and the SDCC (when not used for ONS 15454 DCC terminations). A traditional DCC tunnel endpoint is defined by slot, port, and DCC, where DCC can be either the SDCC or one of the LDCCs. You can link LDCCs to LDCCs and link SDCCs to SDCCs. You can also link an SDCC to an LDCC, and an LDCC to an SDCC. To create a DCC tunnel, you connect the tunnel endpoints from one ONS 15454 optical port to another. Cisco recommends a maximum of 84 DCC tunnel connections for an ONS 15454. Table 11-8 shows the DCC tunnels that you can create using different OC-N cards. Table 11-8 DCC Tunnels Card DCC SONET Layer SONET Bytes OC3 IR 4/STM1 SH 1310 DCC1 Section D1 - D3 OC3 IR/STM1 SH 1310-8; all OC-12, OC-48, and OC-192 cards DCC1 Section D1 - D3 DCC2 Line D4 - D6 DCC3 Line D7 - D9 DCC4 Line D10 - D12 Figure 11-5 shows a DCC tunnel example. Third-party equipment is connected to OC-3 cards at Node 1/Slot 3/Port 1 and Node 3/Slot 3/Port 1. Each ONS 15454 node is connected by OC-48 trunk (span) cards. In the example, three tunnel connections are created, one at Node 1 (OC-3 to OC-48), one at Node 2 (OC-48 to OC-48), and one at Node 3 (OC-48 to OC-3). Figure 11-5 Traditional DCC Tunnel Link 1 From (A) To (B) Slot 3 (OC3) Slot 13 (OC48) Port 1, SDCC Port 1, Tunnel 1 Link 3 From (A) To (B) Slot 12 (OC48) Slot 3 (OC3) Port 1, Tunnel 1 Port 1, SDCC Node 2 Node 3 32134 Node 1 Link 2 From (A) To (B) Slot 12 (OC48) Slot 13 (OC48) Port 1, Tunnel 1 Port 1, Tunnel 1 Third party equipment Third party equipment When you create DCC tunnels, keep the following guidelines in mind: • Each ONS 15454 can have up to 84 DCC tunnel connections. • Each ONS 15454 can have up to 84 Section DCC terminations. • A SDCC that is terminated cannot be used as a DCC tunnel endpoint. • A SDCC that is used as an DCC tunnel endpoint cannot be terminated. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-17 Chapter 11 Circuits and Tunnels 11.5.2 IP-Encapsulated Tunnels • All DCC tunnel connections are bidirectional. 11.5.2 IP-Encapsulated Tunnels An IP-encapsulated tunnel puts an SDCC in an IP packet at a source node and dynamically routes the packet to a destination node. To compare traditional DCC tunnels with IP-encapsulated tunnels, a traditional DCC tunnel is configured as one dedicated path across a network and does not provide a failure recovery mechanism if the path is down. An IP-encapsulated tunnel is a virtual path, which adds protection when traffic travels between different networks. IP-encapsulated tunneling has the potential of flooding the DCC network with traffic resulting in a degradation of performance for CTC. The data originating from an IP tunnel can be throttled to a user-specified rate, which is a percentage of the total SDCC bandwidth. Each ONS 15454 supports up to ten IP-encapsulated tunnels. You can convert a traditional DCC tunnel to an IP-encapsulated tunnel or an IP-encapsulated tunnel to a traditional DCC tunnel. Only tunnels in the DISCOVERED status can be converted. Caution Converting from one tunnel type to the other is service-affecting. 11.6 SDH Tunneling The Cisco ONS 15454 SONET MSPP provides a SDH traffic transport solution with scalable SONET, data or DWDM multiservice capabilities. The SDH traffic is aggregated and transported across an ONS 15454 network, similar to the SONET TDM and data services. STM-1 to STM-64 payloads are transported over SONET from any port on a Cisco ONS 15454 OC-N card provisioned to support SDH signals. For more information on SDH tunneling, refer to the "SDH Tunneling Over Cisco ONS 15454 SONET MSPP Systems Application Note. 11.7 Multiple Destinations for Unidirectional Circuits Unidirectional circuits can have multiple destinations for use in broadcast circuit schemes. In broadcast scenarios, one source transmits traffic to multiple destinations, but traffic is not returned to the source. When you create a unidirectional circuit, the card that does not have its backplane receive (Rx) input terminated with a valid input signal generates a loss of signal (LOS) alarm. To mask the alarm, create an alarm profile suppressing the LOS alarm and apply the profile to the port that does not have its Rx input terminated. 11.8 Monitor Circuits Monitor circuits are secondary circuits that monitor traffic on primary bidirectional circuits. Figure 11-6 shows an example of a monitor circuit. At Node 1, a VT1.5 is dropped from Port 1 of an EC1-12 card. To monitor the VT1.5 traffic, plug test equipment into Port 2 of the EC1-12 card and provision a monitor circuit to Port 2. Circuit monitors are one-way. The monitor circuit in Figure 11-6 monitors VT1.5 traffic received by Port 1 of the EC1-12 card. Cisco ONS 15454 Reference Manual, R8.5.x 11-18 78-18106-01 Chapter 11 Circuits and Tunnels 11.8.1 Monitor Circuits using portless ports as a source on DS3XM-12 Figure 11-6 VT1.5 Monitor Circuit Received at an EC1-12 Port ONS 15454 Node 1 ONS 15454 Node 2 XC XC VT1.5 Drop Test Set Port 1 EC1-12 OC-N OC-N DS1-14 45157 Class 5 Switch Port 2 VT1.5 Monitor 11.8.1 Monitor Circuits using portless ports as a source on DS3XM-12 With STS bi-directional circuit between source and destination and with VT-MAPPED at "circuit source" as an option using DS3XM-12 in 15454 SONET platforms, two circuits will get created: 1) src->even portless port 2) odd portless port->dest Traffic flow from source to dest is as follows: src->even port->odd port->dest While creating Monitor circuit using Even portless port as source, the circuit will get created in the direction towards: dest-> odd portless port-> Even portless port -> dest Monitored port While creating Monitor circuit using odd portless port as source, the circuit will get created in the direction towards: src-> Even portless port-> odd portless port -> dest Monitored port Note Monitor circuits cannot be used with Ethernet circuits. 11.9 Path ProtectionCircuits Use the Edit Circuits window to change path protection selectors and switch protection paths (Figure 11-7). In the Path Protection Selectors subtab in the Edit Circuits window, you can: • View the path protection circuit’s working and protection paths. • Edit the reversion time. • Set the hold-off timer. • Edit the Signal Fail/Signal Degrade thresholds. • Change payload defect indication path (PDI-P) settings. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-19 Chapter 11 Circuits and Tunnels 11.9.1 Open-Ended Path Protection Circuits Note The XC-VXC-10G cross-connect card supports VT switching based on SF and SD bit error rate (BER) thresholds. The XC10G and XCVT cross-connect cards do not support VT switching based on SF and SD BER thresholds, and hence, in the path protection Selectors tab, the SF BER Level and SD BER Level columns display "N/A" for these cards. In the Path Protection Switch Counts subtab, you can: • Perform maintenance switches on the circuit selector. • View switch counts for the selectors. Figure 11-7 Editing Path Protection Selectors 11.9.1 Open-Ended Path Protection Circuits If ONS 15454s are connected to a third-party network, you can create an open-ended path protection circuit to route a circuit through it. To do this, you create four circuits. One circuit is created on the source ONS 15454 network. This circuit has one source and two destinations, each destination provisioned to the ONS 15454 interface that is connected to the third-party network. The second and third circuits are created on the third-party network so that the circuit travels across the network on two diverse paths to the far end ONS 15454. At the destination node, the fourth circuit is created with two sources, one at each node interface connected to the third-party network. A selector at the destination node chooses between the two signals that arrive at the node, similar to a regular path protection circuit. Cisco ONS 15454 Reference Manual, R8.5.x 11-20 78-18106-01 Chapter 11 Circuits and Tunnels 11.9.2 Go-and-Return Path Protection Routing 11.9.2 Go-and-Return Path Protection Routing The go-and-return path protection routing option allows you to route the path protection working path on one fiber pair and the protect path on a separate fiber pair (Figure 11-8). The working path will always be the shortest path. If a fault occurs, both the working and protection fibers are not affected. This feature only applies to bidirectional path protection circuits. The go-and-return option appears in the Circuit Attributes panel of the Circuit Creation wizard. Figure 11-8 Path Protection Go-and-Return Routing Node A Any network Any network Go and Return working connection Go and Return protecting connection 96953 Node B 11.10 BLSR Protection Channel Access Circuits You can provision circuits to carry traffic on BLSR protection channels when conditions are fault-free. Traffic routed on BLSR PCA circuits, called extra traffic, has lower priority than the traffic on the working channels and has no means for protection. During ring or span switches, PCA circuits are preempted and squelched. For example, in a two-fiber OC-48 BLSR, STSs 25 to 48 can carry extra traffic when no ring switches are active, but PCA circuits on these STSs are preempted when a ring switch occurs. When the conditions that caused the ring switch are remedied and the ring switch is removed, PCA circuits are restored. If the BLSR is provisioned as revertive, this occurs automatically after the fault conditions are cleared and the reversion timer has expired. Traffic provisioning on BLSR protection channels is performed during circuit provisioning. The Protection Channel Access check box appears whenever Fully Protected Path is unchecked in the circuit creation wizard. Refer to the Cisco ONS 15454 Procedure Guide for more information. When provisioning PCA circuits, two considerations are important to keep in mind: Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-21 Chapter 11 Circuits and Tunnels 11.11 BLSR STS and VT Squelch Tables • If BLSRs are provisioned as nonrevertive, PCA circuits are not restored automatically after a ring or span switch. You must switch the BLSR manually. • PCA circuits are routed on working channels when you upgrade a BLSR from a two-fiber to a four-fiber or from one optical speed to a higher optical speed. For example, if you upgrade a two-fiber OC-48 BLSR to an OC-192, STSs 25 to 48 on the OC-48 BLSR become working channels on the OC-192 BLSR. 11.11 BLSR STS and VT Squelch Tables ONS 15454 nodes display STS and VT squelch tables depending on the type of circuits created. For example, if a fiber cut occurs, the BLSR squelch tables show STSs or VTs that will be squelched for every isolated node. Squelching replaces traffic by inserting the appropriate alarm indication signal path (AIS-P) and prevents traffic misconnections. For an STS with a VT-access check mark, the AIS-P will be removed after 100 ms. To view the squelch tables, refer to the “Manage Circuits” chapter in the Cisco ONS 15454 Procedure Guide for detailed instructions. For more information about BLSR squelching, refer to Telcordia GR-1230. 11.11.1 BLSR STS Squelch Table BLSR STS squelch tables show STSs that will be squelched for every isolated node. The BLSR Squelch Table window displays the following information: Note • STS Number—Shows the BLSR STS numbers. For two-fiber BLSRs, the number of STSs is half the BLSR OC-N, for example, an OC-48 BLSR squelch table will show 24 STSs. For four-fiber BLSRs, the number of STSs in the table is the same as the BLSR OC-N. • West Source—If traffic is received by the node on its west span, the BLSR node ID of the source appears. (To view the BLSR node IDs for all nodes in the ring, click the Ring Map button.) • West VT (from the West Source) — A check mark indicates that the STS carries incoming VT traffic. The traffic source is coming from the west side. • West VT (from the West Destination) — A check mark indicates that the STS carries outgoing VT traffic. The traffic is dropped on the west side. • West Dest—If traffic is sent on the node’s west span, the BLSR node ID of the destination appears. • East Source—If traffic is received by the node on its east span, the BLSR node ID of the source appears. • East VT — (from the East Source) - A check mark indicates that the STS carries incoming VT traffic. The traffic source is coming from the east side. • East VT — (from the East Destination) - A check mark indicate that the STS carries outgoing VT traffic. The traffic is dropped on the east side. • East Dest—If traffic is sent on the node’s east span, the BLSR node ID of the destination appears. BLSR squelching is performed on STSs that carry STS circuits only. Squelch table entries will not appear for STSs carrying VT circuits or Ethernet circuits to or from E-Series Ethernet cards provisioned in a multicard Ethergroup. Cisco ONS 15454 Reference Manual, R8.5.x 11-22 78-18106-01 Chapter 11 Circuits and Tunnels 11.11.2 BLSR VT Squelch Table 11.11.2 BLSR VT Squelch Table BLSR VT squelch tables only appear on the node dropping VTs from a BLSR and are used to perform VT-level squelching when a node is isolated. VT squelching is supported on the ONS 15454 and the ONS 15327 platforms. The ONS 15600 platform does not support VT squelching; however, when an ONS 15454 and an ONS 15600 are in the same network, the ONS 15600 node allows the ONS 15454 node to carry VT circuits in a VT tunnel. The ONS 15600 performs 100-ms STS-level squelching for each VT-access STS at the switching node in case of a node failure. When using a VT circuit on a VT tunnel (VTT), the VTT allows multiple VT circuits to be passed through on a single STS without consuming VT matrix resources on the cross-connect card. Both endpoints of the VTT are the source and destination nodes for the VTT. The node carrying VT circuits through a VTT is called a VT-access node. In case of a source and destination node failure of the VTT, the switching node performs 100-ms STS-level squelching for the VTT STS. The node dropping VT traffic performs VT-level squelching. VT traffic on the VTT that is not coming from the failed node is protected. When using a VT circuit on a VT aggregation point (VAP), the VAP allows multiple VT circuits to be aggregated into a single STS without consuming VT matrix resources on the cross-connect card. The source for each VAP STS timeslot is the STS-grooming end where VT1.5 circuits are aggregated into a single STS. The destination for each VAP STS is the VT-grooming end where VT1.5 circuits originated. The source node for each VT circuit on a VAP is the STS-grooming end where the VT1.5 circuits are aggregated into a single STS. The STS grooming node is not a VT-access node. The non VT-access node performs STS-level squelching for each STS timeslot at the switching node in case the VT-grooming node fails. The node dropping VT traffic performs VT-level squelching for each VT timeslot in case the STS-grooming end node fails. No VT traffic on the VAP is protected during a failure of the STS-grooming node or the VT-grooming node. To view the VT squelch table, double-click the VT with a check mark in the BLSR STS squelch table window. The check mark appears on every VT-access STS; however, the VT-squelch table appears only by double-clicking the check mark on the node dropping the VT. The intermediate node of the VT does not maintain the VT-squelch table. The VT squelch table provides the following information: • VT Number—Shows the BLSR VT numbers. The VT number includes VT group number and VT number in group (VT group 2 and channel 1 are displayed as 2-1.) • West Source—If traffic is received by the node on its west span, the BLSR node ID of the source appears. (To view the BLSR node IDs for all nodes in the ring, click the Ring Map button.) • East Source—If traffic is received by the node on its east span, the BLSR node ID of the source appears. 11.12 IEEE 802.17 Resilient Packet Ring Circuit Display Resilient Packet Ring (RPR), as described in IEEE 802.17, is a metropolitan area network (MAN) technology supporting data transfer among stations interconnected in a dual-ring configuration. The IEEE 802.17b spatially-aware sublayer amendment is not yet ratified but is expected to add support for bridging to IEEE 802.17. Since the amendment is not yet ratified, no equipment is currently IEEE 802.17b compliant. The RPR-IEEE for ONS 15454 ML-Series cards is based on the expected IEEE 802.17b-based standard. CTC provides a graphical representation (map) of IEEE 802.17 RPR circuits between ML-Series cards with a list of the following information: Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-23 Chapter 11 Circuits and Tunnels 11.13 Section and Path Trace • Circuit name • Type • Size • OCHNC Wlen • Direction • Protection • Status • Source • Destination • # of VLANs • # of Spans • State • Loopback Note CTC does not support the display of Cisco proprietary RPR circuit topologies. Note CTC does not support provisioning or maintenance of IEEE RPR rings. You must use Cisco IOS. For more information about IEEE 802.17 RPR, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. 11.13 Section and Path Trace SONET J0 section and J1 and J2 path trace are repeated, fixed-length strings composed of 16 or 64 consecutive bytes. You can use the strings to monitor interruptions or changes to circuit traffic. The OC192-XFP and MRC-12 cards support J0 section trace. Table 11-9 shows the ONS 15454 cards that support J1 path trace. DS-1 and DS-3 cards can transmit and receive the J1 field, while the EC-1, OC-3, OC-48 AS, and OC-192 can only receive the J1 bytes. Cards that are not listed in the table do not support the J1 byte. The DS3XM-12 card supports J2 path trace for VT circuits. Cisco ONS 15454 Reference Manual, R8.5.x 11-24 78-18106-01 Chapter 11 Circuits and Tunnels 11.14 Path Signal Label, C2 Byte Table 11-9 ONS 15454 Cards Capable of J1 Path Trace J1 Function Cards Transmit and Receive CE-Series DS1-14 1 DS1N-14 DS1/EC1-56 DS3-12E DS3i-N-12 DS3/EC1-48 DS3N-12E DS3XM-6 DS3XM-12 FC_MR-4 G-Series ML-Series Receive Only EC1-12 OC3 IR 4/STM1 SH 1310 OC3 IR 4/STM1 SH 1310-8 OC12/STM4-4 OC48 IR/STM16 SH AS 1310 OC48 LR/STM16 LH AS 1550 OC192 SR/STM64 IO 1310 OC192 LR/STM64 LH 1550 OC192 IR/STM SH 1550 OC192-XFP 1. J1 path trace is not supported for DS-1s used in VT circuits. If the string received at a circuit drop port does not match the string the port expects to receive, an alarm is raised. Two path trace modes are available: • Automatic—The receiving port assumes that the first string it receives is the baseline string. • Manual—The receiving port uses a string that you manually enter as the baseline string. 11.14 Path Signal Label, C2 Byte One of the overhead bytes in the SONET frame is the C2 byte. The SONET standard defines the C2 byte as the path signal label. The purpose of this byte is to communicate the payload type being encapsulated by the STS path overhead (POH). The C2 byte functions similarly to EtherType and Logical Link Control Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-25 Chapter 11 Circuits and Tunnels 11.14 Path Signal Label, C2 Byte (LLC)/Subnetwork Access Protocol (SNAP) header fields on an Ethernet network; it allows a single interface to transport multiple payload types simultaneously. C2 byte hex values are provided in Table 11-10. Table 11-10 STS Path Signal Label Assignments for Signals Hex Code Content of the STS Synchronous Payload Envelope (SPE) 0x00 Unequipped 0x01 Equipped - nonspecific payload 0x02 VT structured STS-1 (DS-1) 0x03 Locked VT mode 0x04 Asynchronous mapping for DS-3 0x12 Asynchronous mapping for DS4NA 0x13 Mapping for Asynchronous Transfer Mode (ATM) 0x14 Mapping for distributed queue dual bus (DQDB) 0x15 Asynchronous mapping for fiber distributed data interface (FDDI) 0x16 High-level data link control (HDLC) over SONET mapping 0x1B Generic Frame Procedure (GFP) used by the FC_MR-4 and ML Series cards 0xFD Reserved 0xFE 0.181 test signal (TSS1 to TSS3) mapping SDH network 0xFF Alarm indication signal, path (AIS-P) If a circuit is provisioned using a terminating card, the terminating card provides the C2 byte. A VT circuit is terminated at the XCVT, XC10G, or XC-VXC-10G card, which generates the C2 byte (0x02) downstream to the STS terminating cards. The XCVT, XC10G, or XC-VXC-10G card generates the C2 value (0x02) to the DS1 or DS3XM terminating card. If an optical circuit is created with no terminating cards, the test equipment must supply the path overhead in terminating mode. If the test equipment is in pass-through mode, the C2 values usually change rapidly between 0x00 and 0xFF. Adding a terminating card to an optical circuit usually fixes a circuit having C2 byte problems. Table 11-11 lists label assignments for signals with payload defects. Table 11-11 STS Path Signal Label Assignments for Signals with Payload Defects Hex Code Content of the STS SPE 0xE1 VT-structured STS-1 SPE with 1 VTx payload defect (STS-1 with 1 VTx PD) 0xE2 STS-1 with 2 VTx PDs 0xE3 STS-1 with 3 VTx PDs 0xE4 STS-1 with 4 VTx PDs 0xE5 STS-1 with 5 VTx PDs 0xE6 STS-1 with 6 VTx PDs 0xE7 STS-1 with 7 VTx PDs 0xE8 STS-1 with 8 VTx PDs 0xE9 STS-1 with 9 VTx PDs Cisco ONS 15454 Reference Manual, R8.5.x 11-26 78-18106-01 Chapter 11 Circuits and Tunnels 11.15 Automatic Circuit Routing Table 11-11 STS Path Signal Label Assignments for Signals with Payload Defects (continued) Hex Code Content of the STS SPE 0xEA STS-1 with 10 VTx PDs 0xEB STS-1 with 11 VTx PDs 0xEC STS-1 with 12 VTx PDs 0xED STS-1 with 13 VTx PDs 0xEE STS-1 with 14 VTx PDs 0xEF STS-1 with 15 VTx PDs 0xF0 STS-1 with 16 VTx PDs 0xF1 STS-1 with 17 VTx PDs 0xF2 STS-1 with 18 VTx PDs 0xF3 STS-1 with 19 VTx PDs 0xF4 STS-1 with 20 VTx PDs 0xF5 STS-1 with 21 VTx PDs 0xF6 STS-1 with 22 VTx PDs 0xF7 STS-1 with 23 VTx PDs 0xF8 STS-1 with 24 VTx PDs 0xF9 STS-1 with 25 VTx PDs 0xFA STS-1 with 26 VTx PDs 0xFB STS-1 with 27 VTx PDs 0xFC VT-structured STS-1 SPE with 28 VT1.5 (Payload defects or a non-VT-structured STS-1 or STS-Nc SPE with a payload defect.) 0xFF Reserved 11.15 Automatic Circuit Routing If you select automatic routing during circuit creation, CTC routes the circuit by dividing the entire circuit route into segments based on protection domains. For unprotected segments of circuits provisioned as fully protected, CTC finds an alternate route to protect the segment, creating a virtual path protection configuration. Each segment of a circuit path is a separate protection domain. Each protection domain is protected in a specific protection scheme including card protection (1+1, 1:1, etc.) or SONET topology (path protection, BLSR, etc.). The following list provides principles and characteristics of automatic circuit routing: • Circuit routing tries to use the shortest path within the user-specified or network-specified constraints. VT tunnels are preferable for VT circuits because VT tunnels are considered shortcuts when CTC calculates a circuit path in path-protected mesh networks. • If you do not choose Fully Path Protected during circuit creation, circuits can still contain protected segments. Because circuit routing always selects the shortest path, one or more links and/or segments can have some protection. CTC does not look at link protection while computing a path for unprotected circuits. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-27 Chapter 11 Circuits and Tunnels 11.15.1 Bandwidth Allocation and Routing Note • Circuit routing does not use links that are down. If you want all links to be considered for routing, do not create circuits when a link is down. • Circuit routing computes the shortest path when you add a new drop to an existing circuit. It tries to find the shortest path from the new drop to any nodes on the existing circuit. • If the network has a mixture of VT-capable nodes and VT-incapable nodes, CTC can automatically create a VT tunnel. Otherwise, CTC asks you whether a VT tunnel is needed. • To create protected circuits between topologies, install an XCVT, XC10G, or XC-VXC-10G cross-connect card on the shared node. • For STS circuits, you can use portless transmux interfaces if a DS3XM-12 card is installed in the network. CTC automatically routes the circuit over the portless transmux interfaces on the specified node creating an end-to-end STS circuit. Automatic routing and its associated subfields are not available if both the Automatic Circuit Routing NE default and the Network Circuit Automatic Routing Overridable NE default are set to FALSE. For a full description of these defaults see Appendix C, “Network Element Defaults.” 11.15.1 Bandwidth Allocation and Routing Within a given network, CTC routes circuits on the shortest possible path between source and destination based on the circuit attributes, such as protection and type. CTC considers using a link for the circuit only if the link meets the following requirements: • The link has sufficient bandwidth to support the circuit. • The link does not change the protection characteristics of the path. • The link has the required time slots to enforce the same time slot restrictions for BLSRs. If CTC cannot find a link that meets these requirements, an error appears. The same logic applies to VT circuits on VT tunnels. Circuit routing typically favors VT tunnels because VT tunnels are shortcuts between a given source and destination. If the VT tunnel in the route is full (no more bandwidth), CTC asks whether you want to create an additional VT tunnel. 11.15.2 Secondary Sources and Destinations CTC supports secondary circuit sources and destinations (drops). Secondary sources and destinations typically interconnect two third-party networks, as shown in Figure 11-9. Traffic is protected while it goes through a network of ONS 15454s. Cisco ONS 15454 Reference Manual, R8.5.x 11-28 78-18106-01 Chapter 11 Circuits and Tunnels 11.16 Manual Circuit Routing Figure 11-9 Secondary Sources and Destinations Primary source Primary destination Vendor A network Vendor B network Secondary source 55402 Secondary destination ONS 15454 network Several rules apply to secondary sources and destinations: • CTC does not allow a secondary destination for unidirectional circuits because you can always specify additional destinations after you create the circuit. • The sources and destinations cannot be DS-3, DS3XM, or DS-1-based STS-1s or VT1.5s. • Secondary sources and destinations are permitted only for regular STS/VT1.5 connections (not for VT tunnels and multicard EtherSwitch circuits). • For point-to-point (straight) Ethernet circuits, only SONET STS endpoints can be specified as multiple sources or destinations. For bidirectional circuits, CTC creates a path protection connection at the source node that allows traffic to be selected from one of the two sources on the ONS 15454 network. If you check the Fully Path Protected option during circuit creation, traffic is protected within the ONS 15454 network. At the destination, another path protection connection is created to bridge traffic from the ONS 15454 network to the two destinations. A similar but opposite path exists for the reverse traffic flowing from the destinations to the sources. For unidirectional circuits, a path protection drop-and-continue connection is created at the source node. 11.16 Manual Circuit Routing Routing circuits manually allows you to: • Choose a specific path, not necessarily the shortest path. • Choose a specific STS/VT1.5 on each link along the route. • Create a shared packet ring for multicard EtherSwitch circuits. • Choose a protected path for multicard EtherSwitch circuits, allowing virtual path protection segments. CTC imposes the following rules on manual routes: • All circuits, except multicard EtherSwitch circuits in a shared packet ring, should have links with a direction that flows from source to destination. This is true for multicard EtherSwitch circuits that are not in a shared packet ring. • If you enabled Fully Path Protected, choose a diverse protect (alternate) path for every unprotected segment (Figure 11-10). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-29 Chapter 11 Circuits and Tunnels 11.16 Manual Circuit Routing Figure 11-10 Alternate Paths for Virtual Path Protection Segments Unidirectional Source Node 1 Unidirectional Twoway Twoway 1+1 Node 2 Node 5 Node 6 Node 9 Node 10 Node 11 Node 12 BLSR ring Node 4 Node 7 Node 8 1+1 Twoway Twoway Twoway Path Segment 1 Path Segment 2 Path/MESH 1+1 protected protected Needs alternate path from N1 to N2 Path Segment 4 1+1 protected No need for alternate path • For multicard EtherSwitch circuits, the Fully Path Protected option is ignored. • For a node that has a path protection selector based on the links chosen, the input links to the path protection selectors cannot be 1+1 or BLSR protected (Figure 11-11). The same rule applies at the path protection bridge. Mixing 1+1 or BLSR Protected Links With a Path Protection Configuration Unidirectional Unidirectional Unidirectional Unidirectional Unprotected Node 1 Node 2 (source) (destination) Node 1 (source) BLSR ring Node 3 Unprotected Node 4 Unidirectional Unidirectional Unprotected Unprotected Node 2 Node 4 Node 3 (destination) Node 4 Unprotected (destination) Unprotected Legal Illegal Node 1 (source) Node 3 Node 2 55404 Figure 11-11 Twoway Twoway Path Segment 3 BLSR protected Drop 1+1 55403 Node 3 1+1 protected Unprotected Illegal • In a shared packet ring, choose the links of multicard EtherSwitch circuits to route from source to destination back to source (Figure 11-12). Otherwise, a route (set of links) chosen with loops is invalid. Cisco ONS 15454 Reference Manual, R8.5.x 11-30 78-18106-01 Chapter 11 Circuits and Tunnels 11.16 Manual Circuit Routing Figure 11-12 Ethernet Shared Packet Ring Routing Ethernet source Node 1 Node 2 Node 3 Node 4 55405 Ethernet destination • Multicard EtherSwitch circuits can have virtual path protection segments if the source or destination is not in the path protection domain. This restriction also applies after circuit creation; therefore, if you create a circuit with path protection segments, Ethernet destinations cannot exist anywhere on the path protection segment (Figure 11-13). Figure 11-13 Ethernet and Path Protection Source Source Node 5 Node 6 Path Protection Segment Node 7 Node 8 Node 5 Node 6 Path Protection Segment Node 7 Node 8 Drop Drop 55406 Node 2 Node 11 Node 11 Legal • Illegal A VT tunnel cannot be the endpoint of a path protection segment. A path protection segment endpoint is where the path protection selector resides. If you provision full path protection, CTC verifies that the route selection is protected at all segments. A route can have multiple protection domains with each domain protected by a different scheme. Table 11-12 through Table 11-15 on page 11-32 summarize the available node connections. Any other combination is invalid and generates an error. Table 11-12 Bidirectional STS/VT/Regular Multicard EtherSwitch/Point-to-Point (Straight) Ethernet Circuits Connection Type Number of Inbound Links Number of Outbound Links Number of Sources Number of Destinations Path protection — 2 1 — Path protection 2 — — 1 Path protection 2 1 — — Path protection 1 2 — — Path protection 1 — — 2 Path protection — 1 2 — Double path protection 2 2 — — Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-31 Chapter 11 Circuits and Tunnels 11.16 Manual Circuit Routing Table 11-12 Bidirectional STS/VT/Regular Multicard EtherSwitch/Point-to-Point (Straight) Ethernet Circuits (continued) Connection Type Number of Inbound Links Number of Outbound Links Number of Sources Number of Destinations Double path protection 2 — — 2 Double path protection — 2 2 — Two way 1 1 — — Ethernet 0 or 1 0 or 1 Ethernet node source — Ethernet 0 or 1 0 or 1 — Ethernet node drop Table 11-13 Unidirectional STS/VT Circuit Connection Type Number of Inbound Links Number of Outbound Links Number of Sources Number of Destinations One way 1 1 — — Path protection headend 1 2 — — Path protection headend — 2 1 — Path protection drop and continue — — 1+ Table 11-14 2 Multicard Group Ethernet Shared Packet Ring Circuit Number of Inbound Links Number of Outbound Links Number of Sources Number of Destinations Double path protection 2 2 — — Two way 1 1 — — 1 — — Connection Type At Intermediate Nodes Only At Source or Destination Nodes Only Ethernet Table 11-15 1 Bidirectional VT Tunnels Connection Type Number of Inbound Links Number of Outbound Links Number of Sources Number of Destinations At Intermediate Nodes Only Path protection 2 1 — — Path protection 1 2 — — Double path protection 2 2 — — Two way 1 1 — — Cisco ONS 15454 Reference Manual, R8.5.x 11-32 78-18106-01 Chapter 11 Circuits and Tunnels 11.17 Constraint-Based Circuit Routing Table 11-15 Bidirectional VT Tunnels (continued) Connection Type Number of Inbound Links Number of Outbound Links Number of Sources Number of Destinations 1 — — — — — At Source Nodes Only VT tunnel endpoint — At Destination Nodes Only VT tunnel endpoint 1 Although virtual path protection segments are possible in VT tunnels, VT tunnels are still considered unprotected. If you need to protect VT circuits, use two independent VT tunnels that are diversely routed or use a VT tunnel that is routed over 1+1, BLSR, or a mixture of 1+1 and BLSR links. 11.17 Constraint-Based Circuit Routing When you create circuits, you can choose Fully Protected Path to protect the circuit from source to destination. The protection mechanism used depends on the path that CTC calculates for the circuit. If the network is composed entirely of BLSR or 1+1 links, or the path between source and destination can be entirely protected using 1+1 or BLSR links, no path-protected mesh network (PPMN), or virtual path protection, protection is used. If PPMN protection is needed to protect the path, set the level of node diversity for the PPMN portions of the complete path in the Circuit Routing Preferences area of the Circuit Creation dialog box: • Nodal Diversity Required—Ensures that the primary and alternate paths of each PPMN domain in the complete path have a diverse set of nodes. • Nodal Diversity Desired—CTC looks for a node diverse path; if a node-diverse path is not available, CTC finds a link-diverse path for each PPMN domain in the complete path. • Link Diversity Only—Creates only a link-diverse path for each PPMN domain. When you choose automatic circuit routing during circuit creation, you have the option to require or exclude nodes and links in the calculated route. You can use this option to achieve the following results: • Simplify manual routing, especially if the network is large and selecting every span is tedious. You can select a general route from source to destination and allow CTC to fill in the route details. • Balance network traffic. By default, CTC chooses the shortest path, which can load traffic on certain links while other links have most of their bandwidth available. By selecting a required node and/or a link, you force the CTC to use (or not use) an element, resulting in more efficient use of network resources. CTC considers required nodes and links to be an ordered set of elements. CTC treats the source nodes of every required link as required nodes. When CTC calculates the path, it makes sure that the computed path traverses the required set of nodes and links and does not traverse excluded nodes and links. The required nodes and links constraint is only used during the primary path computation and only for PPMN domains/segments. The alternate path is computed normally; CTC uses excluded nodes/links when finding all primary and alternate paths on PPMNs. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-33 Chapter 11 Circuits and Tunnels 11.18 Virtual Concatenated Circuits 11.18 Virtual Concatenated Circuits Virtual concatenated (VCAT) circuits, also called VCAT groups (VCGs), transport traffic using noncontiguous TDM time slots, avoiding the bandwidth fragmentation problem that exists with contiguous concatenated (CCAT) circuits. The cards that support VCAT circuits are the CE-Series, FC_MR-4 (both line rate and enhanced mode), and ML-Series cards. In a VCAT circuit, circuit bandwidth is divided into smaller circuits called VCAT members. The individual members act as independent TDM circuits. All VCAT members should be the same size and must originate and terminate at the same end points. For two-fiber BLSR configurations, some members can be routed on protected time slots and others on PCA time slots. To enable end-to-end connectivity in a VCAT circuit that traverses through a third-party network, you can use Open-Ended VCAT circuit creation, or you can create a server trail between the ports. For more details, refer to the "Create Circuits and VT Tunnels" chapter in the Cisco ONS 15454 Procedure Guide. 11.18.1 VCAT Circuit States The state of a VCAT circuit is an aggregate of its member circuits. You can view whether a VCAT member is In Group or Out of Group in the VCAT State column in the Edit Circuits window. • If all member circuits are in the IS state, the VCAT circuit state is IS. • If all In Group member circuits are in the OOS state, the VCAT circuit state is OOS. • If no member circuits exist or if all member circuits are Out of Group, the VCAT circuit state is OOS. • A VCAT circuit is in OOS-PARTIAL state when In Group member states are mixed and not all are in the IS state. 11.18.2 VCAT Member Routing The automatic and manual routing selection applies to the entire VCAT circuit, that is, all members are manually or automatically routed. Bidirectional VCAT circuits are symmetric, which means that the same number of members travel in each direction. With automatic routing, you can specify the constraints for individual members; with manual routing, you can select different spans for different members. Two types of automatic and manual routing are available for VCAT members: common fiber routing and split routing. CE-Series, FC_MR-4 (both line rate and enhanced mode), and ML-Series cards support common fiber routing. In common fiber routing, all VCAT members travel on the same fibers, which eliminates delay between members. Three protection options are available for common fiber routing: Fully Protected, PCA, and Unprotected. Figure 11-14 shows an example of common fiber routing. Cisco ONS 15454 Reference Manual, R8.5.x 11-34 78-18106-01 Chapter 11 Circuits and Tunnels 11.18.2 VCAT Member Routing VCAT Common Fiber Routing VCAT Function Member 1 VCG-1 Member 2 STS-1 STS-1 STS-2 STS-2 Member 1 VCG-1 Member 2 VCAT Function Intermediate NE CE-100T-8 VCAT Function Member 1 VCG-2 Member 2 CE-100T-8 STS-3 STS-3 STS-4 STS-4 Member 1 VCG-2 Member 2 VCAT Function 102170 Figure 11-14 CE-Series cards also support split fiber routing, which allows the individual members to be routed on different fibers or each member to have different routing constraints. This mode offers the greatest bandwidth efficiency and also the possibility of differential delay, which is handled by the buffers on the terminating cards. Four protection options are available for split fiber routing: Fully Protected, PCA, Unprotected, and DRI. Figure 11-15 shows an example of split fiber routing. VCAT Split Fiber Routing Virtually Concatenated Group VCAT Function Traffic Source VCAT at NE Intermediate NE Member #1 Intermediate NE Member #2 Intermediate NE Member #3 VCAT Function with Differential Delay Buffer Traffic Destination VCAT at NE 124065 Figure 11-15 In both common fiber and split fiber routing, each member can use a different protection scheme; however, for common fiber routing, CTC checks the combination to make sure that a valid route exists. If it does not, the user must modify the protection type. In both common fiber and split fiber routing, intermediate nodes treat the VCAT members as normal circuits that are independently routed and protected by the SONET network. At the terminating nodes, these member circuits are multiplexed into a contiguous stream of data. The switch time for split fiber routing depends on the type of circuits traversing the path. • CCAT circuits carry traffic after the SONET defects are cleared. • VCAT circuits carry traffic after the SONET defects are cleared and VCAT framers are in frame for ALL the time slots that are part of the group. Hence the switchover takes extra time. • LCAS circuits carry traffic after the SONET defects are cleared, and the VCAT framers are in frame for any time slots that are part of the group, and the LCAS protocol has fed back MST=OK (MST=Member Status) to the far end so the far end can enable the time slot to carry traffic. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-35 Chapter 11 Circuits and Tunnels 11.18.3 Link Capacity Adjustment Table 11-16 Switch Times Type of circuit For CE100T-8 in ms CCAT 60 HO VCAT HO LCAS 1 90 90 LO VCAT 202 LO LCAS 202 1. The calculated number for HO LCAS includes all the inherent delays of the protocol. Also the CE-100-T numbers are for a group size of only three members. Note The switch time values shown in Table 11-16 does not include differential delay. The maximum differential delay for CE100T-8 is 122ms. This differential delay is added to the switch time to get the maximum time. 11.18.3 Link Capacity Adjustment The CE-100T-8 card supports the link capacity adjustment scheme (LCAS), which is a signaling protocol that allows dynamic bandwidth adjustment of VCAT circuits. When a member fails, a brief traffic hit occurs. LCAS temporarily removes the failed member from the VCAT circuit for the duration of the failure, leaving the remaining members to carry the traffic. When the failure clears, the member circuit is automatically added back into the VCAT circuit without affecting traffic. You can select LCAS during VCAT circuit creation. Note Although LCAS operations are errorless, a SONET error can affect one or more VCAT members. If this occurs, the VCAT Group Degraded (VCG-DEG) alarm is raised. For information on clearing this alarm, refer to the Cisco ONS 15454 Troubleshooting Guide. Instead of LCAS, the FC_MR-4 (enhanced mode), CE-1000-4 card, and ML-Series cards support software LCAS (SW-LCAS). SW-LCAS is a limited form of LCAS that allows the VCAT circuit to adapt to member failures and keep traffic flowing at a reduced bandwidth. SW-LCAS uses legacy SONET failure indicators like AIS-P and remote defect indication, path (RDI-P) to detect member failure. SW-LCAS removes the failed member from the VCAT circuit, leaving the remaining members to carry the traffic. When the failure clears, the member circuit is automatically added back into the VCAT circuit. For ML-Series cards, SW-LCAS allows circuit pairing over two-fiber BLSRs. With circuit pairing, a VCAT circuit is set up between two ML-Series cards: one is a protected circuit (line protection) and the other is a PCA circuit. For four-fiber BLSRs, member protection cannot be mixed. You select SW-LCAS during VCAT circuit creation. The FC_MR-4 (line rate mode) does not support SW-LCAS. In addition, you can create non-LCAS VCAT circuits, which do not use LCAS or SW-LCAS. While LCAS and SW-LCAS member cross-connects can be in different service states, all In Group non-LCAS members must have cross-connects in the same service state. A non-LCAS circuit can mix Out of Group and In Group members, as long as the In Group members are in the same service state. Non-LCAS members do not support the OOS-MA,OOG service state; to put a non-LCAS member in the Out of Group VCAT state, use the OOS-MA,DSBLD administrative state. Cisco ONS 15454 Reference Manual, R8.5.x 11-36 78-18106-01 Chapter 11 Circuits and Tunnels 11.18.4 VCAT Circuit Size Note Protection switching for LCAS, SW-LCAS, and non-LCAS VCAT circuits might exceed 60ms. Traffic loss for VT VCAT circuits is approximately two times more than an STS VCAT circuit. You can minimize traffic loss by reducing path differential delay. 11.18.4 VCAT Circuit Size Table 11-17 lists supported VCAT circuit rates and number of members for each card. Table 11-17 ONS 15454 Card VCAT Circuit Rates and Members Card Circuit Rate Number of Members CE-100T-8 VT1.5 1–64 STS-1 1–3 1 STS-1 1–21 1 STS-3 1–7 STS-1 24 (1 Gbps port) CE-1000-4 FC_MR-4 (line rate mode) 48 (2 Gbps port) STS-3c 8 (1 Gbps port) 16 (2 Gbps port) FC_MR-4 (enhanced mode) STS-1 1–24 (1 Gbps port) 1–48 (2 Gbps port) STS-3c 1–8 (1 Gbps port) 1–16 (2 Gbps port) ML-Series STS-1, STS-3c, STS-12c 2 1. A VCAT circuit with a CE-Series card as a source or destination and an ML-Series card as a source or destination can have only two members. Use the Members tab in the Edit Circuit window to add or delete members from a VCAT circuit. The capability to add or delete members depends on the card and whether the VCAT circuit is LCAS, SW-LCAS, or non-LCAS. • CE-100T-8 cards—You can add or delete members to an LCAS VCAT circuit without affecting service. Before deleting a member of an LCAS VCAT circuit, Cisco recommends that you put the member in the OOS-MA,OOG service state. If you create non-LCAS VCAT circuits, adding and deleting members to the circuit is possible, but service-affecting. • CE-1000-4 cards—You can add or delete SW-LCAS VCAT members, although it might affect service. Before deleting a member, Cisco recommends that you put the member in the OOS-MA,OOG service state. If you create non-LCAS VCAT circuits, adding and deleting members to the circuit is possible, but service-affecting. • FC_MR-4 (enhanced mode) card—You can add or delete SW-LCAS VCAT members, although it might affect service. Before deleting a member, Cisco recommends that you put the member in the OOS-MA,OOG service state. You cannot add or delete members from non-LCAS VCAT circuits on FC_MR-4 cards. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-37 Chapter 11 Circuits and Tunnels 11.18.5 Open-Ended VCAT • FC_MR-4 (line mode) card—All VCAT circuits using FC_MR-4 (line mode) cards have a fixed number of members; you cannot add or delete members. • ML-Series cards—All VCAT circuits using ML-Series cards have a fixed number of members; you cannot add or delete members. Table 11-18 summarizes the VCAT capabilities for each card. Table 11-18 ONS 15454 VCAT Card Capabilities Card Mode Add a Member Delete a Member Support OOS-MA,OOG CE-100T-8 LCAS Yes1 Yes1 Yes SW-LCAS No No No CE-1000-4 Non-LCAS Yes LCAS No SW-LCAS Yes 2 Yes 2 No No Yes 2 Yes No Yes 2 No Non-LCAS Yes SW-LCAS Yes Yes Yes Non-LCAS No No No FC_MR-4 (line mode) Non-LCAS No No No ML-Series SW-LCAS No No No Non-LCAS No No No FC_MR-4 (enhanced mode) 1. When adding or deleting a member from an LCAS VCAT circuit, Cisco recommends that you first put the member in the OOS-MA,OOG service state to avoid service disruptions. 2. For CE-Series cards, you can add or delete members after creating a VCAT circuit with no protection. During the time it takes to add or delete members (from seconds to minutes), the entire VCAT circuit will be unable to carry traffic. 11.18.5 Open-Ended VCAT For applications where the complete end-to-end VCAT circuit is not in a CTC managed network, CTC will only see either the source or the destination of the Virtual Concatenated Group (VCG) and some of the intermediate nodes. Figure 11-16 shows an end-to-end VC AT circuit. The termination points of the end-to-end VCAT circuit, with VCAT functionality, are referred to as the VCAT-Source and VCAT-Destination. The termination points of the CTC managed circuit, which is the Open-Ended VCAT circuit, is referred to as simply the Source and Destination. Cisco ONS 15454 Reference Manual, R8.5.x 11-38 78-18106-01 Chapter 11 Circuits and Tunnels 11.18.5 Open-Ended VCAT Figure 11-16 Open-Ended VCAT Destination SONET/SDH Port VCAT-Destination VCAT-Source Source Destination SONET/SDH Port Non-CTC Managed Network 240645 CTC Managed Network Open-ended VCAT Circuit End-to-end VCAT Circuit Open-ended VCAT circuits can originate or terminate on any pair of OC-N ports and you can route open-ended VCAT circuits using any of the cards and ports supported by VCAT. The CTC circuit creation wizard provides an additional check box in the VCAT attributes pane to enable Open-VCAT circuit creation. Enabling the check box differentiates open-ended VCAT from regular VCAT Circuits. The routing preferences for an open-ended VCAT circuit must be specified in the initial stages of circuit provisioning. For example, if the circuit is independent fiber routing, then multiple OC-N ports can be involved. Alternatively, the source of an open-VCAT circuit should always be a card capable of participating in a VCG. This allows CTC to determine which routing preferences are permissible. Auto ranging of 12 STS1 circuits is supported. 11.18.5.1 Open-Ended VCAT Protection Table 11-19 summarizes the protection options for open-ended VCAT circuits. Note that members can have different routing preferences. Table 11-19 Protection options for Open-Ended VCAT Circuits Routing Preferences Routing Mode Common fiber Manual/Auto Protection Options • Fully protected (Line only) • Unprotected • PCA Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-39 Chapter 11 Circuits and Tunnels 11.19 Bridge and Roll Table 11-19 Protection options for Open-Ended VCAT Circuits Routing Preferences Routing Mode Split fiber Manual/Auto Protection Options • Fully protected (Line only) • Unprotected • PCA • DRI Note Split fiber with secondary destinations Manual/Auto • Note • Path protection is not supported. Fully protected Line protection is not supported. DRI 11.19 Bridge and Roll The CTC Bridge and Roll wizard reroutes live traffic without interrupting service. The bridge process takes traffic from a designated “roll from” facility and establishes a cross-connect to the designated “roll to” facility. When the bridged signal at the receiving end point is verified, the roll process creates a new cross-connect to receive the new signal. When the roll completes, the original cross-connects are released. You can use the bridge and roll feature for maintenance functions such as card or facility replacement, or for load balancing. You can perform a bridge and roll on the following ONS platforms: ONS 15454, ONS 15454 SDH, ONS 15600, ONS 15327, and ONS 15310-CL. 11.19.1 Rolls Window The Rolls window lists information about a rolled circuit before the roll process is complete. You can access the Rolls window by clicking the Circuits > Rolls tabs in either network or node view. Figure 11-17 shows the Rolls window. Cisco ONS 15454 Reference Manual, R8.5.x 11-40 78-18106-01 Chapter 11 Circuits and Tunnels 11.19.1 Rolls Window Figure 11-17 Rolls Window The Rolls window information includes: • Roll From Circuit—The circuit that has connections that will no longer be used when the roll process is complete. • Roll To Circuit—The circuit that will carry the traffic after the roll process is complete. The Roll To Circuit is the same as the Roll From Circuit if a single circuit is involved in a roll. • Roll State—The roll status; see the “11.19.2 Roll Status” section on page 11-42. • Roll Valid Signal—If the Roll Valid Signal status is true, a valid signal was found on the new port. If the Roll Valid Signal status is false, a valid signal was not found. It is not possible to get a Roll Valid Signal status of true for a one-way destination roll. • Roll Mode—The mode indicates whether the roll is automatic or manual. Note CTC implements a roll mode at the circuit level. TL1 implements a roll mode at the cross-connect level. If a single roll is performed, CTC and TL1 behave the same. If a dual roll is performed, the roll mode specified in CTC might be different than the roll mode retrieved in TL1. For example, if you select Automatic, CTC coordinates the two rolls to minimize possible traffic hits by using the Manual mode behind the scenes. When both rolls have a good signal, CTC signals the nodes to complete the roll. – Automatic—When a valid signal is received on the new path, CTC completes the roll on the node automatically. One-way source rolls are always automatic. – Manual—You must complete a manual roll after a valid signal is received. One-way destination rolls are always manual. • Roll Path—The fixed point of the roll object. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-41 Chapter 11 Circuits and Tunnels 11.19.2 Roll Status • Roll From Circuit—The circuit that has connections that will no longer be used when the process is complete. • Roll From Path— The old path that is being rerouted. • Roll To Path—The new path where the Roll From Path is rerouted. • Complete—Completes a manual roll after a valid signal is received. You can do this when a manual roll is in a ROLL_PENDING status and you have not yet completed the roll or have not cancelled its sibling roll. • Force Valid Signal—Forces a roll onto the Roll To Circuit destination without a valid signal. Note If you choose Force Valid Signal, traffic on the circuit that is involved in the roll will be dropped when the roll is completed. • Finish—Completes the circuit processing of both manual and automatic rolls and changes the circuit status from ROLL_PENDING to DISCOVERED. After a roll, the Finish button also removes any cross-connects that are no longer used from the Roll From Circuit field. • Cancel—Cancels the roll process. Note When the roll mode is Manual, cancelling a roll is only allowed before you click the Complete button. When the roll mode is Auto, cancelling a roll is only allowed before a good signal is detected by the node or before clicking the Force Valid Signal button. 11.19.2 Roll Status Table 11-20 lists the roll statuses. Table 11-20 Roll Statuses State Description ROLL_PENDING Roll is awaiting completion or cancellation. ROLL_COMPLETED Roll is complete. Click the Finish button. ROLL_CANCELLED Roll has been canceled. TL1_ROLL A TL1 roll was initiated. Note INCOMPLETE If a roll is created using TL1, a CTC user cannot complete or cancel the roll. Also, if a roll is created using CTC, a TL1 user cannot complete or cancel the roll. You must use the same interface to complete or change a roll. This state appears when the underlying circuit becomes incomplete. To correct this state, you must fix the underlying circuit problem before the roll state will change. For example, a circuit traveling on Nodes A, B, and C can become INCOMPLETE if Node B is rebooted. The cross-connect information is lost on Node B during a reboot. The Roll State on Nodes A and C will change to INCOMPLETE. Cisco ONS 15454 Reference Manual, R8.5.x 11-42 78-18106-01 Chapter 11 Circuits and Tunnels 11.19.3 Single and Dual Rolls Note You can only reroute circuits in the DISCOVERED status. You cannot reroute circuits that are in the ROLL_PENDING status. 11.19.3 Single and Dual Rolls Circuits have an additional layer of roll types: single and dual. A single roll on a circuit is a roll on one of its cross-connects. Use a single roll to: • Change either the source or destination of a selected circuit (Figure 11-18 and Figure 11-19, respectively). • Roll a segment of the circuit onto another chosen circuit (Figure 11-20). This roll also results in a new destination or a new source. In Figure 11-18, you can select any available STS on Node 1 for a new source. S1 Single Source Roll Node 2 Node 1 S2 D Original leg New leg 83267 Figure 11-18 In Figure 11-19, you can select any available STS on Node 2 for a new destination. S Single Destination Roll Node 1 Original leg New leg Node 2 D1 D2 83266 Figure 11-19 Figure 11-20 shows one circuit rolling onto another circuit at the destination. The new circuit has cross-connects on Node 1, Node 3, and Node 4. CTC deletes the cross-connect on Node 2 after the roll. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-43 Chapter 11 Circuits and Tunnels 11.19.3 Single and Dual Rolls S Single Roll from One Circuit to Another Circuit (Destination Changes) Node 1 Node 2 D Node 3 Node 4 D2 78703 Figure 11-20 Original leg New leg Figure 11-21 shows one circuit rolling onto another circuit at the source. Single Roll from One Circuit to Another Circuit (Source Changes) S Node 1 Node 2 S2 Node 3 Node 4 D Original leg New leg Note 134274 Figure 11-21 Create a Roll To Circuit before rolling a circuit with the source on Node 3 and the destination on Node 4. A dual roll involves two cross-connects. It allows you to reroute intermediate segments of a circuit, but keep the original source and destination. If the new segments require new cross-connects, use the Bridge and Roll wizard or create a new circuit and then perform a roll. Caution Only single rolls can be performed using TL1. Dual rolls require the network-level view that only CTC or CTM provide. Dual rolls have several constraints: • You must complete or cancel both cross-connects rolled in a dual roll. You cannot complete one roll and cancel the other roll. • When a Roll To circuit is involved in the dual roll, the first roll must roll onto the source of the Roll To circuit and the second roll must roll onto the destination of the Roll To circuit. Figure 11-22 illustrates a dual roll on the same circuit. Cisco ONS 15454 Reference Manual, R8.5.x 11-44 78-18106-01 Chapter 11 Circuits and Tunnels 11.19.4 Two Circuit Bridge and Roll Figure 11-22 S Dual Roll to Reroute a Link Node 1 Node 2 D 83268 Original leg New leg Figure 11-23 illustrates a dual roll involving two circuits. S Dual Roll to Reroute to a Different Node Node 1 Node 2 Node 3 Node 4 Original leg New leg Note D 83102 Figure 11-23 If a new segment is created on Nodes 3 and 4 using the Bridge and Roll wizard, the created circuit has the same name as the original circuit with the suffix _ROLL**. The circuit source is on Node 3 and the circuit destination is on Node 4. 11.19.4 Two Circuit Bridge and Roll When using the bridge and roll feature to reroute traffic using two circuits, the following constraints apply: • DCC must be enabled on the circuits involved in a roll before roll creation. • A maximum of two rolls can exist between any two circuits. • If two rolls are involved between two circuits, both rolls must be on the original circuit. The second circuit should not carry live traffic. The two rolls loop from the second circuit back to the original circuit. The roll mode of the two rolls must be identical (either automatic or manual). • If a single roll exists on a circuit, you must roll the connection onto the source or the destination of the second circuit and not an intermediate node in the circuit. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-45 Chapter 11 Circuits and Tunnels 11.19.5 Protected Circuits 11.19.5 Protected Circuits CTC allows you to roll the working or protect path regardless of which path is active. You can upgrade an unprotected circuit to a fully protected circuit or downgrade a fully protected circuit to an unprotected circuit with the exception of a path protection circuit. When using bridge and roll on path protection circuits, you can roll the source or destination or both path selectors in a dual roll. However, you cannot roll a single path selector. 11.20 Merged Circuits A circuit merge combines a single selected circuit with one or more circuits. You can merge VT tunnels, VAP circuits, VCAT members, CTC-created circuits, and TL1-created circuits. To merge circuits, you choose a circuit in the CTC Circuits window and the circuits that you want to merge with the chosen (master) circuit on the Merge tab in the Edit Circuits window. The Merge tab shows only the circuits that are available for merging with the master circuit: • Circuit cross-connects must create a single, contiguous path. • Circuits types must be a compatible. For example, you can combine an STS circuit with a VAP circuit to create a longer VAP circuit, but you cannot combine a VT circuit with an STS circuit. • Circuit directions must be compatible. You can merge a one-way and a two-way circuit, but not two one-way circuits in opposing directions. • Circuit sizes must be identical. • VLAN assignments must be identical. • Circuit end points must send or receive the same framing format. • The merged circuits must become a DISCOVERED circuit. If all connections from the master circuit and all connections from the merged circuits align to form one complete circuit, the merge is successful. If all connections from the master circuit and some, but not all, connections from the other circuits align to form a single complete circuit, CTC notifies you and gives you the chance to cancel the merge process. If you choose to continue, the aligned connections merge successfully into the master circuit, and the unaligned connections remain in the original circuits. All connections in the completed master circuit use the original master circuit name. All connections from the master circuit and at least one connection from the other selected circuits must be used in the resulting circuit for the merge to succeed. If a merge fails, the master circuit and all other circuits remain unchanged. When the circuit merge completes successfully, the resulting circuit retains the name of the master circuit. You can also merge orderwire and user data channel (UDC) overhead circuits, which use the overhead bytes instead of frame payload to transfer data. To merge overhead circuits, you choose the overhead circuits on the network view Provisioning > Overhead Circuits window. You can only merge orderwire and UDC circuits. Cisco ONS 15454 Reference Manual, R8.5.x 11-46 78-18106-01 Chapter 11 Circuits and Tunnels 11.21 Reconfigured Circuits 11.21 Reconfigured Circuits You can reconfigure multiple circuits, which is typically necessary when a large number of circuits are in the PARTIAL status. When reconfiguring multiple circuits, the selected circuits can be any combination of DISCOVERED, PARTIAL, DISCOVERED_TL1, or PARTIAL_TL1 circuits. You can reconfigure tunnels, VAP circuits, VLAN-assigned circuits, VCAT circuits, CTC-created circuits, and TL1-created circuits. The Reconfigure command maintains the names of the original cross-connects. Use the CTC Tools > Circuits > Reconfigure Circuits menu item to reconfigure selected circuits. During reconfiguration, CTC reassembles all connections of the selected circuits and VCAT members into circuits based on path size, direction, and alignment. Some circuits might merge and others might split into multiple circuits. If the resulting circuit is a valid circuit, it appears as a DISCOVERED circuit. Otherwise, the circuit appears as a PARTIAL or PARTIAL_TL1 circuit. Note If CTC cannot reconfigure all members in a VCAT circuit, the reconfigure operation fails for the entire VCAT circuit and it remains in the PARTIAL or PARTIAL_TL1 status. If CTC does reconfigure all members in a VCAT circuit, the VCAT circuit may still remain in the PARTIAL or PARTIAL_TL1 status. This occurs if the ports defined in the VCAT termination do not match the source/drop ports of the member circuits or if one or two VCAT terminations are missing. Note PARTIAL tunnel and PARTIAL VLAN-capable circuits do not split into multiple circuits during reconfiguration. 11.22 VLAN Management In Software Release 4.6 and later, VLANs are populated within topologies to limit broadcasts to each topology rather than to the entire network. Using the Manage VLANs command in the Tools menu, you can view a list of topology hosts and provisioned VLANs. You create VLANs during circuit creation or with the Manage VLANs command. When creating a VLAN, you must identify the topology host (node) where the VLAN will be provisioned. The Manage VLANs command also allows you to delete existing VLANs. 11.23 Server Trails A server trail is a non-DCC (logical or virtual) link across a third-party network that connects two CTC network domains. A server trail allows A-Z circuit provisioning when no DCC is available. You can create server trails between two distant optical or EC-1 ports. The end ports on a server trail can be different types (for example, an OC-3 port can be linked to an OC-12 port). Server trails are not allowed on DCC-enabled ports. The server trail link is bidirectional and can be VT1.5, VT2, STS1, STS-3c, STS-6c, STS-12c, STS-48c, or STS-192c; you cannot change an existing server trail to another size. It must be deleted and recreated. A circuit provisioned over a server trail must match the type and size of the server trail it uses. For example, an STS-3c server trail can carry only STS-3c circuits and not three STS-1 circuits. Note There is no OSPF or any other management information exchange between NEs over a server trail. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-47 Chapter 11 Circuits and Tunnels 11.23.1 Server Trail Protection Types 11.23.1 Server Trail Protection Types The server trail protection type determines the protection type for any circuits that traverse it. A server trail link can be one of the following protection types: Note • Preemptible—PCA circuits will use server trails with the Preemptible attribute. • Unprotected—In Unprotected Server Trail, CTC assumes that the circuits going out from that specific port will not be protected by provider network and will look for a secondary path from source to destination if you are creating a protected circuit. • Fully Protected—In Fully Protected Server Trail, CTC assumes that the circuits going out from that specific port will be protected by provider network and will not look for a secondary path from source to destination. Only path protection is available on server trails. BLSR protection is not available on server trail. 11.23.2 VCAT Circuit Routing over Server Trails An STS-3c server trail can be used to route STS-3c circuits and an STS-1 server trail can be used to route STS-1 circuits. Similarly, a VT1.5 server trail can be used to route VT1.5 circuits and an STS-12c server trail can only be used for STS-12c circuits. For example, to route a STS-3c-2v circuit over a server trail, you must enable split fiber routing and create two STS-3c server trails and route each member manually or automatically over each server trail. To route a STS-12c-2v circuit over a server trail, you must enable split fiber routing and create two STS-12c server trails and route each member manually or automatically over each server trail. Note Server trails can only be created between any two optical ports or EC-1 ports. VCAT circusits can be created over server trails in the following ways: • Manual routing • Automatic routing – Diverse routing: This method enables VCAT circuit routing over diverse server trail links. Note When creating circuits or VCATs, you can choose a server trail link during manual circuit routing. CTC may also route circuits over server trail links during automatic routing. VCAT common-fiber automatic routing is not supported. For a detailed procedure on how to route a VCAT circuit over a server trail, refer “Chapter 6, Create Circuits and VT Tunnels, Section NTP-A264, Create an Automatically Routed VCAT Circuit and Section NTP-A265, Create a Manually Routed VCAT Circuit” in the Cisco ONS 15454 Procedure Guide. Cisco ONS 15454 Reference Manual, R8.5.x 11-48 78-18106-01 Chapter 11 Circuits and Tunnels 11.23.2 VCAT Circuit Routing over Server Trails 11.23.2.1 Shared Resource Link Group The Shared Resource Link Group (SRLG) attribute can be assigned to a server trail link using a commonly shared resource such as port, fiber or span. For example, if two server trail links are routed over the same fiber, an SRLG attribute can be assigned to these links. SRLG is used by Cisco Transport Manager (CTM) to specify link diversity. If you create multiple server trails from one port, you can assign the same SRLG value to all the links to indicate that they originate from the same port. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 11-49 Chapter 11 Circuits and Tunnels 11.23.2 VCAT Circuit Routing over Server Trails Cisco ONS 15454 Reference Manual, R8.5.x 11-50 78-18106-01 CH A P T E R 12 SONET Topologies and Upgrades Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This chapter explains Cisco ONS 15454 SONET topologies and upgrades. To provision topologies, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 12.1 SONET Rings and TCC2/TCC2P Cards, page 12-1 • 12.2 Bidirectional Line Switched Rings, page 12-3 • 12.3 Path Protection, page 12-14 • 12.4 Dual-Ring Interconnect, page 12-19 • 12.5 Comparison of the Protection Schemes, page 12-28 • 12.6 Subtending Rings, page 12-29 • 12.7 Linear ADM Configurations, page 12-31 • 12.8 Path-Protected Mesh Networks, page 12-31 • 12.9 Four-Shelf Node Configurations, page 12-33 • 12.10 STS around the Ring, page 12-34 • 12.11 OC-N Speed Upgrades, page 12-35 • 12.12 In-Service Topology Upgrades, page 12-38 12.1 SONET Rings and TCC2/TCC2P Cards Table 12-1 shows the SONET rings that can be created on each ONS 15454 node using redundant TCC2/TCC2P cards. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-1 Chapter 12 SONET Topologies and Upgrades 12.1 SONET Rings and TCC2/TCC2P Cards Table 12-1 ONS 15454 Rings with Redundant TCC2/TCC2P Cards Ring Type Maximum Rings per Node BLSRs 5 2-Fiber BLSR 5 4-Fiber BLSR 1 Path protection with SDCC 341,2 Path protection with LDCC 143,4 Cisco ONS 15454 Reference Manual, R8.5.x 12-2 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.2 Bidirectional Line Switched Rings Table 12-1 ONS 15454 Rings with Redundant TCC2/TCC2P Cards (continued) Ring Type Maximum Rings per Node Path protection with LDCC and SDCC 265 1. Total SDCC usage must be equal to or less than 84 SDCCs. 2. See the “12.3 Path Protection” section on page 12-14. 3. Total LDCC usage must be equal to or less than 28 LDCCs. 4. See the “12.3 Path Protection” section on page 12-14. 5. Total LDCC and SDCC usage must be equal to or less than 84. When LDCC is provisioned, an SDCC termination is allowed on the same port, but is not recommended. Using SDCC and LDCC on the same port is only needed during a software upgrade if the other end of the link does not support LDCC. You can provision SDCCs and LDCCs on different ports in the same node. 12.2 Bidirectional Line Switched Rings The ONS 15454 can support five concurrent bidirectional line switch rings (BLSRs) in one of the following configurations: • Five two-fiber BLSRs • Four two-fiber and one four-fiber BLSR Each BLSR can have up to 32 ONS 15454s. Because the working and protect bandwidths must be equal, you can create only OC-12 (two-fiber only), OC-48, or OC-192 BLSRs. Note For best performance, BLSRs should have one LAN connection for every ten nodes in the BLSR. 12.2.1 Two-Fiber BLSRs In two-fiber BLSRs, each fiber is divided into working and protect bandwidths. For example, in an OC-48 BLSR (Figure 12-1), STSs 1 to 24 carry the working traffic, and STSs 25 to 48 are reserved for protection. Working traffic (STSs 1 to 24) travels in one direction on one fiber and in the opposite direction on the second fiber. The Cisco Transport Controller (CTC) circuit routing routines calculate the shortest path for circuits based on many factors, including user requirements, traffic patterns, and distance. For example, in Figure 12-1, circuits going from Node 0 to Node 1 typically travel on Fiber 1, unless that fiber is full, in which case circuits are routed on Fiber 2 through Node 3 and Node 2. Traffic from Node 0 to Node 2 (or Node 1 to Node 3) can be routed on either fiber, depending on circuit provisioning requirements and traffic loads. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-3 Chapter 12 SONET Topologies and Upgrades 12.2.1 Two-Fiber BLSRs Figure 12-1 Four-Node, Two-Fiber BLSR STSs 1-24 (working) STSs 25-48 (protect) Node 0 STSs 1-24 (working) STSs 25-48 (protect) OC-48 Ring Node 1 = Fiber 1 Node 2 = Fiber 2 61938 Node 3 The SONET K1, K2, and K3 bytes carry the information that governs BLSR protection switches. Each BLSR node monitors the K bytes to determine when to switch the SONET signal to an alternate physical path. The K bytes communicate failure conditions and actions taken between nodes in the ring. If a break occurs on one fiber, working traffic targeted for a node beyond the break switches to the protect bandwidth on the second fiber. The traffic travels in a reverse direction on the protect bandwidth until it reaches its destination node. At that point, traffic is switched back to the working bandwidth. Figure 12-2 shows a traffic pattern sample on a four-node, two-fiber BLSR. Cisco ONS 15454 Reference Manual, R8.5.x 12-4 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.2.1 Two-Fiber BLSRs Figure 12-2 Four-Node, Two-Fiber BLSR Traffic Pattern Sample Node 0 Node 3 OC-48 Ring Node 1 Fiber 1 Node 2 Fiber 2 61956 Traffic flow Figure 12-3 shows how traffic is rerouted following a line break between Node 0 and Node 3. • All circuits originating on Node 0 that carried traffic to Node 2 on Fiber 2 are switched to the protect bandwidth of Fiber 1. For example, a circuit carrying traffic on STS-1 on Fiber 2 is switched to STS-25 on Fiber 1. A circuit carried on STS-2 on Fiber 2 is switched to STS-26 on Fiber 1. Fiber 1 carries the circuit to Node 3 (the original routing destination). Node 3 switches the circuit back to STS-1 on Fiber 2 where it is routed to Node 2 on STS-1. • Circuits originating on Node 2 that normally carried traffic to Node 0 on Fiber 1 are switched to the protect bandwidth of Fiber 2 at Node 3. For example, a circuit carrying traffic on STS-2 on Fiber 1 is switched to STS-26 on Fiber 2. Fiber 2 carries the circuit to Node 0 where the circuit is switched back to STS-2 on Fiber 1 and then dropped to its destination. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-5 Chapter 12 SONET Topologies and Upgrades 12.2.2 Four-Fiber BLSRs Figure 12-3 Four-Node, Two-Fiber BLSR Traffic Pattern Following Line Break Node 0 Node 3 OC-48 Ring Node 1 Fiber 1 Node 2 Fiber 2 61957 Traffic flow 12.2.2 Four-Fiber BLSRs Four-fiber BLSRs double the bandwidth of two-fiber BLSRs. Because they allow span switching as well as ring switching, four-fiber BLSRs increase the reliability and flexibility of traffic protection. Two fibers are allocated for working traffic and two fibers for protection, as shown in Figure 12-4. To implement a four-fiber BLSR, you must install four OC-48, OC-48 AS, or OC-192 cards at each BLSR node. Cisco ONS 15454 Reference Manual, R8.5.x 12-6 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.2.2 Four-Fiber BLSRs Figure 12-4 Four-Node, Four-Fiber BLSR Node 0 Span 4 Span 1 Span 5 Span 8 OC-48 Ring Span 6 Node 1 Span 7 Span 3 Span 2 = Working fibers Node 2 = Protect fibers 61932 Node 3 Four-fiber BLSRs provide span and ring switching: • Span switching (Figure 12-5 on page 12-8) occurs when a working span fails. Traffic switches to the protect fibers between the nodes (Node 0 and Node 1 in the example in Figure 12-5) and then returns to the working fibers. Multiple span switches can occur at the same time. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-7 Chapter 12 SONET Topologies and Upgrades 12.2.2 Four-Fiber BLSRs Figure 12-5 Four-Fiber BLSR Span Switch Node 0 Span 4 Span 1 Span 5 Span 8 OC-48 Ring Span 6 Node 1 Span 7 Span 3 Span 2 = Working fibers Node 2 • = Protect fibers 61959 Node 3 Ring switching (Figure 12-6) occurs when a span switch cannot recover traffic, such as when both the working and protect fibers fail on the same span. In a ring switch, traffic is routed to the protect fibers throughout the full ring. Cisco ONS 15454 Reference Manual, R8.5.x 12-8 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.2.3 BLSR Bandwidth Figure 12-6 Four-Fiber BLSR Ring Switch Node 0 Span 4 Span 1 Span 5 Span 8 OC-48 Ring Span 6 Node 1 Span 7 Span 3 Span 2 = Working fibers = Protect fibers Node 2 61960 Node 3 12.2.3 BLSR Bandwidth BLSR nodes can terminate traffic coming from either side of the ring. Therefore, BLSRs are suited for distributed node-to-node traffic applications such as interoffice networks and access networks. BLSRs allow bandwidth to be reused around the ring and can carry more traffic than a network with traffic flowing through one central hub. BLSRs can also carry more traffic than a path protection configuration operating at the same OC-N rate. Table 12-2 shows the bidirectional bandwidth capacities of two-fiber BLSRs. The capacity is the OC-N rate divided by two, multiplied by the number of nodes in the ring minus the number of pass-through STS-1 circuits. Table 12-2 Two-Fiber BLSR Capacity OC Rate Working Bandwidth Protection Bandwidth Ring Capacity OC-12 STS1-6 STS 7-12 6 x N1 – PT2 OC-48 STS 1-24 STS 25-48 24 x N – PT OC-192 STS 1-96 STS 97-192 96 x N – PT 1. N equals the number of ONS 15454 nodes configured as BLSR nodes. 2. PT equals the number of STS-1 circuits passed through ONS 15454 nodes in the ring (capacity can vary depending on the traffic pattern). Table 12-3 shows the bidirectional bandwidth capacities of four-fiber BLSRs. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-9 Chapter 12 SONET Topologies and Upgrades 12.2.4 BLSR Application Example Table 12-3 Four-Fiber BLSR Capacity OC Rate Working Bandwidth Protection Bandwidth Ring Capacity OC-48 STS 1-48 (Fiber 1) STS 1-48 (Fiber 2) 48 x N 1 – PT2 OC-192 STS 1-192 (Fiber 1) STS 1-192 (Fiber 2) 192 x N – PT 1. N equals the number of ONS 15454 nodes configured as BLSR nodes. 2. PT equals the number of STS-1 circuits passed through ONS 15454 nodes in the ring (capacity can vary depending on the traffic pattern). Figure 12-7 shows an example of BLSR bandwidth reuse. The same STS carries three different traffic sets simultaneously on different spans around the ring: one set from Node 3 to Node 1, another set from Node 1 to Node 2, and another set from Node 2 to Node 3. Figure 12-7 BLSR Bandwidth Reuse Node 0 STS#1 STS#1 Node 3 Node 1 STS#1 STS#1 Node 2 = Node 1 – Node 2 traffic = Node 2 – Node 3 traffic 32131 = Node 3 – Node 1 traffic 12.2.4 BLSR Application Example Figure 12-8 shows a two-fiber BLSR implementation example with five nodes. A regional long-distance network connects to other carriers at Node 0. Traffic is delivered to the service provider’s major hubs. • Carrier 1 delivers six DS-3s over two OC-3 spans to Node 0. Carrier 2 provides twelve DS-3s directly. Node 0 receives the signals and delivers them around the ring to the appropriate node. • The ring also brings 14 DS-1s back from each remote site to Node 0. Intermediate nodes serve these shorter regional connections. Cisco ONS 15454 Reference Manual, R8.5.x 12-10 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.2.4 BLSR Application Example • The ONS 15454 OC-3 card supports a total of four OC-3 ports so that two additional OC-3 spans can be added at little cost. Figure 12-8 Five-Node Two-Fiber BLSR Carrier 1 2 OC-3s 56 local Carrier 2 DS-1s 12 DS-3s 4 DS-3s Node 0 14 DS-1s Node 1 14 DS-1s 2 DS-3s Node 4 Node 2 14 DS-1s 8 DS-3s = Fiber 1 4 DS-3s 14 DS-1s = Fiber 2 32138 Node 3 Figure 12-9 shows the shelf assembly layout for Node 0, which has one free slot. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-11 Chapter 12 SONET Topologies and Upgrades 12.2.4 BLSR Application Example Figure 12-9 Shelf Assembly Layout for Node 0 in Figure 12-8 134608 DS3-12 DS3-12 OC3 OC3 OC48 OC48 TCC2/TCC2P Cross Connect AIC-I (Optional) Cross Connect TCC2/TCC2P Free Slot DS1-14 DS1-14 DS1N-14 DS1-14 DS1-14 Figure 12-10 shows the shelf assembly layout for the remaining sites in the ring. In this BLSR configuration, an additional eight DS-3s at Node IDs 1 and 3 can be activated. An additional four DS-3s can be added at Node 4, and ten DS-3s can be added at Node 2. Each site has free slots for future traffic needs. Figure 12-10 Shelf Assembly Layout for Nodes 1 to 4 in Figure 12-8 134605 DS3-12 DS3-12 Free Slot Free Slot OC48 OC48 TCC2/TCC2P Cross Connect AIC-I (Optional) Cross Connect TCC2/TCC2P Free Slot Free Slot Free Slot Free Slot DS1-14 DS1-14 Cisco ONS 15454 Reference Manual, R8.5.x 12-12 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.2.5 BLSR Fiber Connections 12.2.5 BLSR Fiber Connections Plan your fiber connections and use the same plan for all BLSR nodes. For example, make the east port the farthest slot to the right and the west port the farthest slot to the left. Plug fiber connected to an east port at one node into the west port on an adjacent node. Figure 12-11 shows fiber connections for a two-fiber BLSR with trunk cards in Slot 5 (west) and Slot 12 (east). Refer to the Cisco ONS 15454 Procedure Guide for fiber connection procedures. Always plug the transmit (Tx) connector of an OC-N card at one node into the receive (Rx) connector of an OC-N card at the adjacent node. Cards display an SF LED when Tx and Rx connections are mismatched. Figure 12-11 Connecting Fiber to a Four-Node, Two-Fiber BLSR Tx Rx West Tx Rx East West Slot 12 Slot 5 Tx Rx Node 2 Tx Rx West Slot 12 Node 4 Tx Rx Tx Rx East Slot 5 East Slot 12 Slot 5 Node 1 Tx Rx Tx Rx West East Slot 12 Slot 5 55297 Note Node 3 For four-fiber BLSRs, use the same east-west connection pattern for the working and protect fibers. Do not mix working and protect card connections. The BLSR does not function if working and protect cards are interconnected. Figure 12-12 shows fiber connections for a four-fiber BLSR. Slot 5 (west) and Slot 12 (east) carry the working traffic. Slot 6 (west) and Slot 13 (east) carry the protect traffic. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-13 Chapter 12 SONET Topologies and Upgrades 12.3 Path Protection Connecting Fiber to a Four-Node, Four-Fiber BLSR West Node 1 Node 2 Tx Rx Tx Rx East West Slot Slot 12 13 Slot Slot 6 5 Tx Rx West East Slot Slot 12 13 Slot Slot 5 6 Slot Slot 12 13 Slot Slot 6 5 Tx Rx East Node 4 West East Slot Slot 12 13 Slot Slot 5 6 Node 3 Working fibers Protect fibers 61958 Figure 12-12 12.3 Path Protection Path Protection Configurations(PPC) provide duplicate fiber paths around the ring. Working traffic flows in one direction and protection traffic flows in the opposite direction. If a problem occurs with the working traffic path, the receiving node switches to the path coming from the opposite direction. CTC automates ring configuration. path protection traffic is defined within the ONS 15454 on a circuit-by-circuit basis. If a path-protected circuit is not defined within a 1+1 or BLSR line protection scheme and path protection is available and specified, CTC uses path protection as the default. A path protection circuit requires two DCC-provisioned optical spans per node. Path protection circuits can be created across these spans until their bandwidth is consumed. Note If a path protection circuit is created manually by TL1, data communications channels (DCCs) are not needed; therefore, path protection circuits are limited by the cross-connection bandwidth or the span bandwidth, but not by the number of DCCs. The span bandwidth consumed by a path protection circuit is two times the circuit bandwidth, because the circuit is duplicated. The cross-connection bandwidth consumed by a path protection circuit is three times the circuit bandwidth at the source and destination nodes only. The cross-connection bandwidth consumed by an intermediate node has a factor of one. Cisco ONS 15454 Reference Manual, R8.5.x 12-14 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.3 Path Protection The path protection circuit limit is the sum of the optical bandwidth containing 84 section data communication channels (SDCCs) or 28 line data communication channels (LDCCs), divided by two if you are using redundant TCC2/TCC2P cards. The spans can be of any bandwidth from OC-3 to OC-192. The circuits can be of any size from VT1.5 to 192c. Figure 12-13 shows a basic four-node path protection configuration. If Node ID 0 sends a signal to Node ID 2, the working signal travels on the working traffic path through Node ID 1. The same signal is also sent on the protect traffic path through Node ID 3. Figure 12-13 Basic Four-Node Path Protection ONS 15454 Node ID 0 ONS 15454 Node ID 3 ONS 15454 Node ID 1 = Fiber 1 = Fiber 2 32148 ONS 15454 Node ID 2 If a fiber break occurs (Figure 12-14), Node ID 2 switches its active receiver to the protect signal coming through Node ID 3. Because each traffic path is transported around the entire ring, path protection configurations are best suited for networks where traffic concentrates at one or two locations and is not widely distributed. Path protection capacity is equal to its bit rate. Services can originate and terminate on the same path protection, or they can be passed to an adjacent access or interoffice ring for transport to the service-terminating location. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-15 Chapter 12 SONET Topologies and Upgrades 12.3 Path Protection Figure 12-14 Path Protection with a Fiber Break Source ONS 15454 Node ID 0 Span 4 Span 5 Span 8 ONS 15454 Node ID 3 ONS 15454 Node ID 1 Span 6 Span 3 Span 1 Span 7 Span 2 Destination ONS 15454 Node ID 2 = Fiber 1 = Fiber 2 32639 Fiber break Figure 12-15 shows a common path protection application. OC-3 optics provide remote switch connectivity to a host Telcordia TR-303 switch. In the example, each remote switch requires eight DS-1s to return to the host switch. Figure 12-16 on page 12-18 and Figure 12-17 on page 12-18 show the shelf layout for each site. Cisco ONS 15454 Reference Manual, R8.5.x 12-16 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.3 Path Protection Figure 12-15 Four-Port, OC-3 Path Protection TR-303 Switch ONS 15454 Node ID 0 8 DS-1s ONS 15454 Node ID 3 ONS 15454 Node ID 1 8 DS-1s = Fiber 1 8 DS-1s = Fiber 2 32149 ONS 15454 Node ID 2 Node ID 0 has four DS1-14 cards to provide 56 active DS-1 ports. The other sites only require two DS1-14 cards to handle the eight DS-1s to and from the remote switch. You can use the other half of each ONS 15454 shelf assembly to provide support for a second or third ring to other existing or planned remote sites. In the OC-3 path protection sample, Node ID 0 contains four DS1-14 cards and two OC3 IR 4 1310 cards. Six free slots can be provisioned with cards or left empty. Figure 12-16 shows the shelf setup for these card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-17 Chapter 12 SONET Topologies and Upgrades 12.3 Path Protection Figure 12-16 Layout of Node ID 0 in the OC-3 Path Protection Example in Figure 12-15 134606 Free Slot Free Slot Free Slot Free Slot Free Slot Free Slot TCC2/TCC2P Cross Connect AIC-I (Optional) Cross Connect TCC2/TCC2P OC3 IR 4 1310 OC3 IR 4 1310 DS1-14 DS1-14 DS1-14 DS1-14 In the Figure 12-15 on page 12-17 example, Nodes IDs 1 to 3 each contain two DS1-14 cards and two OC3 IR 4 1310 cards. Eight free slots exist. They can be provisioned with other cards or left empty. Figure 12-17 shows the shelf assembly setup for this configuration example. Figure 12-17 Layout of Node IDs 1 to 3 in the OC-3 Path Protection Example in Figure 12-15 134607 Free Slot Free Slot Free Slot Free Slot Free Slot Free Slot TCC2/TCC2P Cross Connect AIC-I (Optional) Cross Connect TCC2/TCC2P OC3 IR 4 1310 OC3 IR 4 1310 Free Slot Free Slot DS1-14 DS1-14 Cisco ONS 15454 Reference Manual, R8.5.x 12-18 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.4 Dual-Ring Interconnect 12.4 Dual-Ring Interconnect Dual-ring interconnect (DRI) topologies provide an extra level of path protection for circuits on interconnected rings. DRI allows users to interconnect BLSRs, path protection configurations, or a path protection with a BLSR, with additional protection provided at the transition nodes. In a DRI topology, ring interconnections occur at two or four nodes. The drop-and-continue DRI method is used for all ONS 15454 DRIs. In drop-and-continue DRI, a primary node drops the traffic to the connected ring and routes traffic to a secondary node within the same ring. The secondary node also routes the traffic to the connected ring; that is, the traffic is dropped at two different interconnection nodes to eliminate single points of failure. To route circuits on DRI, you must choose the Dual Ring Interconnect option during circuit provisioning. Dual transmit is not supported. Two DRI topologies can be implemented on the ONS 15454: • A traditional DRI requires two pairs of nodes to interconnect two networks. Each pair of user-defined primary and secondary nodes drops traffic over a pair of interconnection links to the other network. • An integrated DRI requires one pair of nodes to interconnect two networks. The two interconnected nodes replace the interconnection ring. For DRI topologies, a hold-off timer sets the amount of time before a selector switch occurs. It reduces the likelihood of multiple switches, such as: • Both a service selector and a path selector • Both a line switch and a path switch of a service selector For example, if a path protection DRI service selector switch does not restore traffic, then the path selector switches after the hold-off time. The path protection DRI hold-off timer default is 100 ms. You can change this setting in the Path Protection Selectors tab of the Edit Circuits window. For BLSR DRI, if line switching does not restore traffic, then the service selector switches. The hold-off time delays the recovery provided by the service selector. The BLSR DRI default hold-off time is 100 ms, but it can be changed. 12.4.1 BLSR DRI Unlike BLSR automatic protection switching (APS) protocol, BLSR-DRI is a path-level protection protocol at the circuit level. Drop-and-continue BLSR-DRI requires a service selector in the primary node for each circuit routing to the other ring. Service selectors monitor signal conditions from dual feed sources and select the one that has the best signal quality. Same-side routing drops the traffic at primary nodes set up on the same side of the connected rings, and opposite-side routing drops the traffic at primary nodes set up on the opposite sides of the connected rings. For BLSR-DRI, primary and secondary nodes cannot be the circuit source or destination. Note A DRI circuit cannot be created if an intermediate node exists on the interconnecting link. However, an intermediate node can be added on the interconnecting link after the DRI circuit is created. DRI protection circuits act as protection channel access (PCA) circuits. In CTC, you set up DRI protection circuits by selecting the PCA option when setting up primary and secondary nodes during DRI circuit creation. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-19 Chapter 12 SONET Topologies and Upgrades 12.4.1 BLSR DRI Figure 12-18 shows ONS 15454 nodes in a traditional BLSR-DRI topology with same-side routing. In Ring 1, Nodes 3 and 4 are the interconnect nodes, and in Ring 2, Nodes 8 and 9 are the interconnect nodes. Duplicate signals are sent between Node 4 (Ring 1) and Node 9 (Ring 2), and between Node 3 (Ring 1) and Node 8 (Ring 2). The primary nodes (Nodes 4 and 9) are on the same side, and the secondary nodes (Nodes 3 and 8) provide an alternative route. In Ring 1, traffic at Node 4 is dropped (to Node 9) and continued (to Node 3). Similarly, at Node 9, traffic is dropped (to Node 4) and continued (to Node 8). Figure 12-18 ONS 15454 Traditional BLSR Dual-Ring Interconnect (Same-Side Routing) Node 1 Node 5 Node 2 BLSR Ring 1 Secondary Node Primary Node Node 4 Node 3 Node 9 Node 8 Secondary Node Primary Node BLSR Ring 2 Node 10 Node 7 Node 6 Drop and Continue Primary Path, Drop and Continue to Bridge Secondary Path 115235 Service Selector Cisco ONS 15454 Reference Manual, R8.5.x 12-20 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.4.1 BLSR DRI Figure 12-19 shows ONS 15454 nodes in a traditional BLSR-DRI topology with opposite-side routing. In Ring 1, Nodes 3 and 4 are the interconnect nodes, and in Ring 2, Nodes 8 and 9 are the interconnect nodes. Duplicate signals are sent from Node 4 (Ring 1) to Node 8 (Ring 2), and between Node 3 (Ring 1) and Node 9 (Ring 2). In Ring 1, traffic at Node 4 is dropped (to Node 9) and continued (to Node 3). Similarly, at Node 8, traffic is dropped (to Node 3) and continued (to Node 8). Figure 12-19 ONS 15454 Traditional BLSR Dual-Ring Interconnect (Opposite-Side Routing) Node 1 Node 5 Node 2 BLSR Ring 1 Secondary Node Primary Node Node 4 Node 3 Node 9 Node 8 Primary Node Secondary Node BLSR Ring 2 Node 10 Node 7 Node 6 Drop and Continue Primary Path, Drop and Continue to Bridge Secondary Path 115234 Service Selector Figure 12-20 shows ONS 15454s in an integrated BLSR-DRI topology. The same drop-and-continue traffic routing occurs at two nodes, rather than four. This is achieved by installing an additional OC-N trunk at the two interconnect nodes. Nodes 3 and 8 are the interconnect nodes. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-21 Chapter 12 SONET Topologies and Upgrades 12.4.1 BLSR DRI Figure 12-20 ONS 15454 Integrated BLSR Dual-Ring Interconnect Node 1 Node 2 BLSR 1 Primary Secondary Node 3 Node 4 Node 8 Secondary Primary Node 5 BLSR 2 Node 7 Node 6 Primary Path (working) Secondary Path (protection) 115236 Service Selector Figure 12-21 shows an example of an integrated BLSR DRI on the Edit Circuits window. Cisco ONS 15454 Reference Manual, R8.5.x 12-22 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.4.2 Path Protection DRI Figure 12-21 Integrated BLSR DRI on the Edit Circuits Window 12.4.2 Path Protection DRI Figure 12-22 shows ONS 15454 nodes in a traditional drop-and-continue path protection DRI topology. In Ring 1, Nodes 4 and 5 are the interconnect nodes, and in Ring 2, Nodes 6 and 7 are the interconnect nodes. Duplicate signals are sent between Node 4 (Ring 1) and Node 6 (Ring 2), and between Node 5 (Ring 1) and Node 7 (Ring 2). In Ring 1, traffic at Node 4 is dropped (to Node 6) and continued (to Node 5). Similarly, at Node 5, traffic is dropped (to Node 7) and continued (to Node 4). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-23 Chapter 12 SONET Topologies and Upgrades 12.4.2 Path Protection DRI Figure 12-22 ONS 15454 Traditional Path Protection Dual-Ring Interconnect Node 1 Node 3 UPSR Ring 1 Node 4 Node 2 Node 5 Duplicate Signals Node 6 Node 7 UPSR Ring 2 Pass-through Node Bridge Path Selector Primary Path, Primary Return Path, Primary Return Path, Secondary 85761 Primary Path, Secondary Figure 12-23 shows ONS 15454 nodes in an integrated DRI topology. The same drop-and-continue traffic routing occurs at two nodes, rather than four. This is achieved by installing an additional OC-N trunk at the two interconnect nodes. Cisco ONS 15454 Reference Manual, R8.5.x 12-24 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.4.2 Path Protection DRI Figure 12-23 ONS 15454 Integrated Path Protection Dual-Ring Interconnect DS1/EC1/DS3/GigE ONS 15454 Path Protection Configuration 1 ONS 15454 DRI Node 1 of 2 supporting two-rings with integrated STS-1 and VT1.5 grooming Duplicate Signals Cross Connect Cross Connect ONS 15454 Path Protection Configuration 2 Bridge Pass-through Node DS1/EC1/DS3/GigE Path Selector Primary Path, Primary Primary Path, Secondary Return Path, Secondary 85762 Return Path, Primary Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-25 Chapter 12 SONET Topologies and Upgrades 12.4.3 Path Protection/BLSR DRI Handoff Configurations 12.4.3 Path Protection/BLSR DRI Handoff Configurations Path protection configurations and BLSRs can also be interconnected. In BLSR/path protectionDRI handoff configurations, primary and secondary nodes can be the circuit source or destination, which is useful when non-DCC optical interconnecting links are present. Figure 12-24 shows an example of a path protection to BLSR traditional DRI handoff. Figure 12-24 ONS 15454 Path Protection to BLSR Traditional DRI Handoff Node 5 Node 2 Node 1 Path Protection Configuration Node 4 Node 3 Node 6 Node 7 BLSR Node 9 Node 10 Node 8 Bridge Primary Path (working) 115273 Path Selector Secondary Path (protection) Figure 12-25 shows an example of a path protection to BLSR integrated DRI handoff. Cisco ONS 15454 Reference Manual, R8.5.x 12-26 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.4.3 Path Protection/BLSR DRI Handoff Configurations Figure 12-25 ONS 15454 Path Protection to BLSR Integrated DRI Handoff Node 5 Node 1 Node 2 Path Protection Configuration Node 4 Node 3 BLSR Node 7 Node 8 Node 6 Bridge 115272 Path Selector Figure 12-26 shows a path protection to BLSR integrated DRI handoff on the Edit Circuits window. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-27 Chapter 12 SONET Topologies and Upgrades 12.5 Comparison of the Protection Schemes Figure 12-26 Path Protection to BLSR Integrated DRI Handoff on the Detailed Circuit Map 12.5 Comparison of the Protection Schemes Table 12-4 shows a comparison of the different protection schemes using OC-48 as an example. Table 12-4 Comparison of the Protection Schemes Topology Ring Capacity Protected Bandwidth Between Any Two Nodes Path Protection 48 - PT Two-Fiber BLSR 24 x N1 PT2 Four-Fiber BLSR Protection Channel Access Dual Failure STS 1-48 Not supported Not supported 2xN STS 1-24 STS 25-48 Not supported 2xN 48 x N - PT STS 1-48 (Fiber 1) STS 1-48 (Fiber 2) Supported 4xN Two-Fiber BLSR DRI 24 x N - PT STS 1-24 STS 25-48 Supported (2 x N) + 4 Path Protection DRI 48 - PT Not supported Supported (2 x N) + 4 STS 1-48 Number of Cards 1. N equals the number of ONS 15454 nodes configured as BLSR nodes. 2. PT equals the number of STS-1 circuits passed through ONS 15454 nodes in the ring (capacity can vary depending on the traffic pattern). Cisco ONS 15454 Reference Manual, R8.5.x 12-28 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.6 Subtending Rings 12.6 Subtending Rings The ONS 15454 supports up to 84 SONET SDCCs or 28 SONET LDCCs with TCC2/TCC2P cards. See Table 12-1 on page 12-2 for ring, SDCC, and LDCC information. Subtending rings reduce the number of nodes and cards required, and reduce external shelf-to-shelf cabling. Figure 12-27 shows an ONS 15454 with multiple subtending rings. Figure 12-27 ONS 15454 with Multiple Subtending Rings Path Protected Nodes BLSR 55302 BLSR Figure 12-28 shows a path protection configuration subtending from a BLSR. In this example, Node 3 is the only node serving both the BLSR and the path protection configuration. OC-N cards in Slots 5 and 12 serve the BLSR, and OC-N cards in Slots 6 and 13 serve the path protection configuration. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-29 Chapter 12 SONET Topologies and Upgrades 12.6 Subtending Rings Figure 12-28 Path Protection Subtending from a BLSR Node 4 Node 1 Slot 5 Slot 6 Slot 13 Slot 12 Slot 13 Slot 12 BLSR Slot 6 Slot 5 Node 3 55303 Slot 5 Slot 12 Node 2 The ONS 15454 can support two BLSRs on the same node. This allows you to deploy an ONS 15454 in applications requiring SONET Digital Cross-connect Systems (DCSs) or multiple SONET add/drop multiplexers (ADMs). Figure 12-29 shows two BLSRs shared by one ONS 15454. Ring 1 runs on Nodes 1, 2, 3, and 4. Ring 2 runs on Nodes 4, 5, 6, and 7. Two BLSR rings, Ring 1 and Ring 2, are provisioned on Node 4. Ring 1 uses cards in Slots 5 and 12, and Ring 2 uses cards in Slots 6 and 13. Nodes in different BLSRs can have the same, or different node IDs. Note BLSR Subtending from a BLSR Node 1 Slot 5 West Node 5 Slot 12 East Slot 12 East Slot 6 West Slot 5 West Slot 13 East BLSR Ring 1 Node 2 Slot 6 West BLSR Ring 2 Slot 12 East Slot 5 West Slot 12 East East Slot 13 Slot 5 West Node 3 Node 4 Slot 6 West Node 6 Slot 13 East Slot 13 East Slot 6 West Node 7 55298 Figure 12-29 Cisco ONS 15454 Reference Manual, R8.5.x 12-30 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.7 Linear ADM Configurations After subtending two BLSRs, you can route circuits from nodes in one ring to nodes in the second ring. For example, in Figure 12-29 you can route a circuit from Node 1 to Node 7. The circuit would normally travel from Node 1 to Node 4 to Node 7. If fiber breaks occur, for example between Nodes 1 and 4 and Nodes 4 and 7, traffic is rerouted around each ring: in this example, Nodes 2 and 3 in Ring 1 and Nodes 5 and 6 in Ring 2. 12.7 Linear ADM Configurations You can configure ONS 15454s as a line of add/drop multiplexers (ADMs) by configuring one set of OC-N cards as the working path and a second set as the protect path. Unlike rings, point-to-point ADMs (two-node configurations) and linear ADMs (three-node configurations) require that the OC-N cards at each node be in 1+1 protection to ensure that a break to the working line is automatically routed to the protect line. Figure 12-30 shows three ONS 15454 nodes in a linear ADM configuration. Working traffic flows from Slot 5/Node 1 to Slot 5/Node 2, and from Slot 12/Node 2 to Slot 12/Node 3. You create the protect path by placing Slot 6 in 1+1 protection with Slot 5 at Nodes 1 and 2, and Slot 12 in 1+1 protection with Slot 13 at Nodes 2 and 3. Node 1 Linear (Point-to-Point) ADM Configuration Slot 5 to Slot 5 Slot 12 to Slot 12 Slot 6 to Slot 6 Slot 13 to Slot 13 Node 2 34284 Figure 12-30 Node 3 Protect Path Working Path 12.8 Path-Protected Mesh Networks In addition to single BLSRs, path protection configurations, and ADMs, you can extend ONS 15454 traffic protection by creating path-protected mesh networks (PPMNs). PPMNs include multiple ONS 15454 SONET topologies and extend the protection provided by a single path protection to the meshed architecture of several interconnecting rings. In a PPMN, circuits travel diverse paths through a network of single or multiple meshed rings. When you create circuits, you can have CTC automatically route circuits across the PPMN, or you can manually route them. You can also choose levels of circuit protection. For example, if you choose full protection, CTC creates an alternate route for the circuit in addition to the main route. The second route follows a unique path through the network between the source and destination and sets up a second set of cross-connections. For example, in Figure 12-31 a circuit is created from Node 3 to Node 9. CTC determines that the shortest route between the two nodes passes through Node 8 and Node 7, shown by the dotted line, and automatically creates cross-connections at Nodes 3, 8, 7, and 9 to provide the primary circuit path. If full protection is selected, CTC creates a second unique route between Nodes 3 and 9 which, in this example, passes through Nodes 2, 1, and 11. Cross-connections are automatically created at Nodes 3, 2, 1, 11, and 9, shown by the dashed line. If a failure occurs on the primary path, traffic switches to the second circuit path. In this example, Node 9 switches from the traffic coming in from Node 7 to the traffic coming in from Node 11 and service resumes. The switch occurs within 50 ms. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-31 Chapter 12 SONET Topologies and Upgrades 12.8 Path-Protected Mesh Networks Figure 12-31 Path-Protected Mesh Network Source Node Node 3 Node 5 Node 2 Node 4 Node 1 Node 10 Node 8 Node 6 Node 7 Node 11 Node 9 c raffi ng t ki Wor Destination Node = Primary path = Secondary path 32136 Protect traffic PPMN also allows spans with different SONET speeds to be mixed together in “virtual rings.” Figure 12-32 shows Nodes 1, 2, 3, and 4 in a standard OC-48 ring. Nodes 5, 6, 7, and 8 link to the backbone ring through OC-12 fiber. The “virtual ring” formed by Nodes 5, 6, 7, and 8 uses both OC-48 and OC-12 cards. Cisco ONS 15454 Reference Manual, R8.5.x 12-32 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.9 Four-Shelf Node Configurations Figure 12-32 ONS 15454 Node 5 PPMN Virtual Ring ONS 15454 Node 4 ONS 15454 Node 1 OC-12 ONS 15454 Node 8 OC-12 32137 OC-48 ONS 15454 Node 6 ONS 15454 Node 2 ONS 15454 Node 3 ONS 15454 Node 7 12.9 Four-Shelf Node Configurations You can link multiple ONS 15454s using their OC-N cards (that is, create a fiber-optic bus) to accommodate more access traffic than a single ONS 15454 can support. Refer to the Cisco ONS 15454 Procedure Guide. For example, to drop more than 112 DS-1s or 96 DS-3s (the maximum that can be aggregated in a single node), you can link the nodes but not merge multiple nodes into a single ONS 15454. You can link nodes with OC-12 or OC-48 fiber spans as you would link any other two network nodes. The nodes can be grouped in one facility to aggregate more local traffic. Figure 12-33 on page 12-34 shows a four-shelf node setup. Each shelf assembly is recognized as a separate node in the ONS 15454 software interface and traffic is mapped using CTC cross-connect options. In Figure 12-33, each node uses redundant fiber-optic cards. Node 1 uses redundant OC-N transport and OC-N bus (connecting) cards for a total of four cards, with eight free slots remaining. Nodes 2 and 3 each use two redundant OC-N bus cards for a total of four cards, with eight free slots remaining. Node 4 uses redundant OC-12 bus cards for a total of two cards, with ten free slots remaining. The four-shelf node example presented here is one of many ways to set up a multiple-node configuration. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-33 Chapter 12 SONET Topologies and Upgrades 12.10 STS around the Ring Figure 12-33 Four-Shelf Node Configuration Redundant OC-N Feed Up to 72 DS-3s, 84 DS-1s Redundant OC-N Bus ONS 15454, Node 1 Up to 72 DS-3s, 84 DS-1s Redundant OC-N Bus ONS 15454, Node 2 Up to 72 DS-3s, 84 DS-1s Redundant OC-N Bus ONS 15454, Node 3 ONS 15454, Node 4 32097 Up to 96 DS-3s, 112 DS-1s 12.10 STS around the Ring You can provision STS circuits with a source endpoint and a destination endpoint on the same node, and route the traffic around a ring. The circuit source and destination can be on the same card, but you must use two different ports on the card, see Figure 12-34 on page 12-35. Manual routing is required for STS around the ring circuits amd “Route Automatically” must be unchecked in the CTC circuit provisioning pane. STS around ring circuits created using Transaction Language 1 (TL1) are discovered by CTC and the status “COMPLETE” is displayed. STS around the ring supports circuit sizes; STS-1, 3c, 6c, 9c, 12c, 24c, 36c, 48c, and 192cs. Both unidirectional and bidirectional circuits are supported, and STS around the ring circuits are CCAT only, VCAT is not supported. STS around ring circuits are linear circuits. Cisco ONS 15454 Reference Manual, R8.5.x 12-34 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.11 OC-N Speed Upgrades Figure 12-34 STS Around the Ring ONS 15454 Node 2 Source ONS 15454 Node 1 ONS 15454 Node 3 ONS 15454 Node 4 240644 Drop 12.11 OC-N Speed Upgrades A span is the optical fiber connection between two ONS 15454 nodes. In a span (optical speed) upgrade, the transmission rate of a span is upgraded from a lower to a higher OC-N signal but all other span configuration attributes remain unchanged. With multiple nodes, a span upgrade is a coordinated series of upgrades on all nodes in the ring or protection group. You can perform in-service span upgrades for the following ONS 15454 cards: • Single-port OC-12 to OC-48 • Single-port OC-12 to OC-192 • Single-port OC-12 to four-port OC-12 • Single-port OC-12 to MRC-12 • Four-port OC-12 to MRC-2.5G-4 • OC-48 to OC-192 • MRC-12 to OC-192 or OC192-XFP • MRC-2.5G-4 to OC-192 or OC192-XFP • OC-48 to OC192SR1/STM64IO Short Reach or OC192/STM64 Any Reach Note Only Software Release 8.5.3 or higher supports span upgrades on MRC-12 and MRC-2.5G-4 cards to OC-192 or OC192-XFP. To perform this span upgrade the card’s SFP must be in PPM Slot 1 only. You can also perform in-service card upgrades for the following ONS 15454 cards: • Four-port OC-3 to eight-port OC-3 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-35 Chapter 12 SONET Topologies and Upgrades 12.11 OC-N Speed Upgrades • Four-port OC-3 to MRC-2.5G-4 • Single-port OC-12 to four-port OC-12 • Single-port OC-12 to OC-48 • Single-port OC-12 to OC-192 • Single-port OC-12 to MRC-12 • Single-port OC-12 to MRC-2.5G-4 • OC-48 to MRC-12 • OC-192 to OC192-XFP • OC-48 to OC192SR1/STM64IO Short Reach or OC192/STM64 Any Reach Table 12-5 lists permitted upgrades for Slots 5, 6, 12, and 13 (high-speed slots). Table 12-5 Slot 5, 6, 12, and 13 Upgrade Options Four-port OC-3 Eight-port OC-3 One-port OC-12 Four-port OC-12 OC-48 OC-192 MRC-12 MRC-2.5G-4 Four-port OC-3 — Not supported Not supported Not supported Not supported Not supported Not supported Supported Eight-port OC-31 Not supported — Not supported Not supported Not supported Not supported Not supported Not supported One-port OC-12 Not supported Not supported — Not supported Supported Supported Supported Not supported Four-port OC-122 Not supported Not supported Not supported — Not supported Not supported Not supported Supported OC-48 Not supported Not supported Supported Not supported — Supported Supported Supported OC-192 Not supported Not supported Supported Not supported Supported — Supported3 Supported3 MRC-12 Not supported Not supported Supported Not supported Supported Supported 3 — Not supported MRC-2.5G-4 Supported Not supported Not supported Supported Supported Supported 3 Not supported — Cards 1. The eight-port OC-3 is not supported in Slots 5, 6, 12, and 13. 2. The four-port OC-12 is not supported in Slots 5, 6, 12, and 13. 3. Only for Software Release 8.5.3 or higher. Table 12-6 lists permitted upgrades for Slots 1 through 4 and 14 through 17 (low-speed slots). Cisco ONS 15454 Reference Manual, R8.5.x 12-36 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.11 OC-N Speed Upgrades Table 12-6 Upgrade Options for Slots 1 through 4 and 14 through 17 Cards Four-port OC-3 Eight-port OC-3 One-port OC-12 Four-port OC-12 OC-48 OC-192 MRC-2.5G-4 MRC-12 Four-port OC-3 — Supported Not supported Not supported Not supported — Supported Not supported Eight-port OC-3 Supported — Not supported Not supported Not supported — Not supported Not supported One-port OC-12 Not supported Not supported — Supported Supported — Not Supported Supported Four-port OC-12 Not supported Not supported Supported — Not supported — Supported Not supported OC-48 Not supported Not supported Supported Not supported — — Supported Supported OC-1921 — — — — — — — Not supported MRC-2.5G-4 Supported Not supported Not Supported Supported Supported — — Not supported MRC-12 Not supported Not supported Supported Not supported Supported — Not supported — 1. The OC-192 is not supported on Slots 1 through 4 and 14 through 17. Note Replacing cards that are the same speed are not considered span upgrades. For example replacing a four-port OC-3 with an eight-port OC-3 card or replacing a single-port OC-12 with a four-port OC-12 card. To perform a span upgrade, the higher-rate OC-N card must replace the lower-rate card in the same slot. If the upgrade is conducted on spans residing in a BLSR, all spans in the ring must be upgraded. The protection configuration of the original lower-rate OC-N card (two-fiber BLSR, four-fiber BLSR, path protection, and 1+1) is retained for the higher-rate OC-N card. To perform a span upgrade on either the OC192-XFP or MRC-12 card with an SFP/XFP (known as pluggable port modules, PPMs, in CTC), the higher-rate PPM must replace the lower-rate PPM in the same slot. If you are using a multi-rate PPM, you do not need to physically replace the PPM but can provision the PPM for a different line rate. All spans in the network must be upgraded. The 1+1 protection configuration of the original lower-rate PPM is retained for the higher-rate PPM. When performing span upgrades on a large number of nodes, we recommend that you upgrade all spans in a ring consecutively and in the same maintenance window. Until all spans are upgraded, mismatched card types or PPM types are present. We recommend using the Span Upgrade Wizard to perform span upgrades. Although you can also use the manual span upgrade procedures, the manual procedures are mainly provided as error recovery for the wizard. The Span Upgrade Wizard and the Manual Span Upgrade procedures require at least two technicians (one at each end of the span) who can communicate with each other during the upgrade. Upgrading a span is non-service affecting and causes no more than three switches, each of which is less than 50 ms in duration. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-37 Chapter 12 SONET Topologies and Upgrades 12.11.1 Span Upgrade Wizard Note Span upgrades do not upgrade SONET topologies (for example, a 1+1 group to a two-fiber BLSR). Refer to the Cisco ONS 15454 Procedure Guide for topology upgrade procedures. 12.11.1 Span Upgrade Wizard The Span Upgrade Wizard automates all steps in the manual span upgrade procedure (BLSR, path protection, and 1+1). The wizard can upgrade both lines on one side of a four-fiber BLSR or both lines of a 1+1 group; the wizard upgrades path protection configurations and two-fiber BLSRs one line at a time. The Span Upgrade Wizard requires that all working spans have DCC enabled. The Span Upgrade Wizard provides no way to back out of an upgrade. In the case of an error, you must exit the wizard and initiate the manual procedure to either continue with the upgrade or back out of it. To continue with the manual procedure, examine the standing conditions and alarms to identify the stage in which the wizard failure occurred. 12.11.2 Manual Span Upgrades Manual span upgrades are mainly provided as error recovery for the Span Upgrade Wizard, but they can be used to perform span upgrades. Downgrading can be performed to back out of a span upgrade. The procedure for downgrading is the same as upgrading except that you choose a lower-rate card type. You cannot downgrade if circuits exist on the STSs that will be removed (the higher STSs). Procedures for manual span upgrades can be found in the “Upgrade Cards and Spans” chapter in the Cisco ONS 15454 Procedure Guide. Five manual span upgrade options are available: • Upgrade on a two-fiber BLSR • Upgrade on a four-fiber BLSR • Upgrade on a path protection configuration • Upgrade on a 1+1 protection group • Upgrade on an unprotected span 12.12 In-Service Topology Upgrades Topology upgrades can be performed in-service to convert a live network to a different topology. An in-service topology upgrade is potentially service-affecting, and generally allows a traffic hit of 50 ms or less. Traffic might not be protected during the upgrade. The following in-service topology upgrades are supported: • Unprotected point-to-point or linear ADM to path protection • Point-to-point or linear ADM to two-fiber BLSR • Path protection to two-fiber BLSR • Two-fiber to four-fiber BLSR • Node addition or removal from an existing topology You can perform in-service topology upgrades irrespective of the service state of the involved cross-connects or circuits; however, a circuit must have a DISCOVERED status. Cisco ONS 15454 Reference Manual, R8.5.x 12-38 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.12.1 Unprotected Point-to-Point or Linear ADM to Path Protection Circuit types supported for in-service topology upgrades are: • STS, VT, and VT tunnels • Virtual concatenated circuits (VCAT) • Unidirectional and bidirectional • Automatically routed and manually routed • CTC-created and TL1-created • Ethernet (unstitched) • Multiple source and destination (both sources should be on one node and both drops on one node) You cannot upgrade stitched Ethernet circuits during topology conversions. For in-service topology upgrade procedures, refer to the “Convert Network Configurations” chapter in the Cisco ONS 15454 Procedure Guide. For procedures to add or remove a node, refer to the “Add and Remove Nodes” chapter of the Cisco ONS 15454 Procedure Guide. Note A database restore on all nodes in a topology returns converted circuits to their original topology. Note Open-ended path protection and DRI configurations do not support in-service topology upgrades. 12.12.1 Unprotected Point-to-Point or Linear ADM to Path Protection CTC provides a topology conversion wizard for converting an unprotected point-to-point or linear ADM topology to path protection. This conversion occurs at the circuit level. CTC calculates the additional path protection circuit route automatically or you can do it manually. When routing the path protection circuit, you can provision the USPR as go-and-return or unidirectional. When performing an in-service topology upgrade on a configuration with VCAT circuits, CTC allows you to select member circuits to upgrade individually. When upgrading VT tunnels, CTC does not convert the VT tunnel to path protection, but instead creates a secondary tunnel for the alternate path. The result is two unprotected VT tunnels using alternate paths. To convert from point-to-point or linear ADM to a path protection, the topology requires an additional circuit route to complete the ring. When the route is established, CTC creates circuit connections on any intermediate nodes and modifies existing circuit connections on the original circuit path. The number and position of network spans in the topology remains unchanged during and after the conversion. Figure 12-35 shows an unprotected point-to-point ADM configuration converted to a path protection. An additional circuit routes through Node 3 to complete the path protection. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-39 Chapter 12 SONET Topologies and Upgrades 12.12.2 Point-to-Point or Linear ADM to Two-Fiber BLSR Figure 12-35 Unprotected Point-to-Point ADM to Path Protection Conversion ONS 15454 Node 1 ONS 15454 Node 4 OC-12 37 OC-48 ONS 15454 Node 8 12.12.2 Point-to-Point or Linear ADM to Two-Fiber BLSR A 1+1 point-to-point or linear ADM to a two-fiber BLSR conversion is manual. You must remove the protect fibers from all nodes in the linear ADM and route them from the end node to the protect port on the other end node. In addition, you must delete the circuit paths that are located in the bandwidth that will become the protection portion of the two-fiber BLSR (for example, circuits in STS 25 or higher on an OC-48 BLSR) and recreate them in the appropriate bandwidth. Finally, you must provision the nodes as BLSR nodes. To complete a conversion from an unprotected point-to-point or linear ADM to a two-fiber BLSR, use the CTC Convert Unprotected/Path Protection to BLSR wizard from the Tools > Topology Upgrade menu. 12.12.3 Path Protection to Two-Fiber BLSR CTC provides a topology conversion wizard to convert a path protection to a two-fiber BLSR. An upgrade from a path protection to a two-fiber BLSR changes path protection to line protection. A path protection can have a maximum of 16 nodes before conversion. Circuits paths must occupy the same time slots around the ring. Only the primary path through the path protection is needed; the topology conversion wizard removes the alternate path protection path during the conversion. Because circuit paths can begin and end outside of the topology, the conversion might create line-protected segments within path protection paths of circuits outside the scope of the ring. The physical arrangement of the ring nodes and spans remains the same after the conversion. Cisco ONS 15454 Reference Manual, R8.5.x 12-40 78-18106-01 Chapter 12 SONET Topologies and Upgrades 12.12.4 Two-Fiber BLSR to Four-Fiber BLSR 12.12.4 Two-Fiber BLSR to Four-Fiber BLSR CTC provides a wizard to convert two-fiber OC-48 or OC-192 BLSRs to four-fiber BLSRs. To convert the BLSR, you must install two OC-48 or OC-192 cards at each two-fiber BLSR node, then log into CTC and convert each node from two-fiber to four-fiber. The fibers that were divided into working and protect bandwidths for the two-fiber BLSR are now fully allocated for working BLSR traffic. 12.12.5 Add or Remove a Node from a Topology You can add or remove a node from a linear ADM, BLSR, or path protection configuration. Adding or removing nodes from BLSRs is potentially service affecting; however, adding and removing nodes from an existing 1+1 linear ADM or path protection configuration does not disrupt traffic. CTC provides a wizard for adding a node to a point-to-point or 1+1 linear ADM. This wizard is used when adding a node between two other nodes. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 12-41 Chapter 12 SONET Topologies and Upgrades 12.12.5 Add or Remove a Node from a Topology Cisco ONS 15454 Reference Manual, R8.5.x 12-42 78-18106-01 CH A P T E R 13 Management Network Connectivity This chapter provides an overview of ONS 15454 data communications network (DCN) connectivity. Cisco Optical Networking System (ONS) network communication is based on IP, including communication between Cisco Transport Controller (CTC) computers and ONS 15454 nodes, and communication among networked ONS 15454 nodes. The chapter provides scenarios showing Cisco ONS 15454 nodes in common IP network configurations as well as information about provisionable patchcords, the IP routing table, external firewalls, and open gateway network element (GNE) networks. Although ONS 15454 DCN communication is based on IP, ONS 15454 nodes can be networked to equipment that is based on the Open System Interconnection (OSI) protocol suites. This chapter also describes the ONS 15454 OSI implementation and provides scenarios that show how the ONS 15454 can be networked within a mixed IP and OSI environment. Note This chapter does not provide a comprehensive explanation of IP networking concepts and procedures, nor does it provide IP addressing examples to meet all networked scenarios. For ONS 15454 networking setup instructions, refer to the “Turn Up a Node” chapter of the Cisco ONS 15454 Procedure Guide. Chapter topics include: Note • 13.1 IP Networking Overview, page 13-1 • 13.2 IP Addressing Scenarios, page 13-2 • 13.3 Routing Table, page 13-24 • 13.4 External Firewalls, page 13-25 • 13.5 Open GNE, page 13-27 • 13.6 TCP/IP and OSI Networking, page 13-29 • 13.7 IPv6 Network Compatibility, page 13-62 • 13.8 FTP Support for ENE Database Backup, page 13-62 To connect ONS 15454s to an IP network, you must work with a LAN administrator or other individual at your site who has IP networking training and experience. 13.1 IP Networking Overview ONS 15454s can be connected in many different ways within an IP environment: Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-1 Chapter 13 Management Network Connectivity 13.2 IP Addressing Scenarios • They can be connected to LANs through direct connections or a router. • IP subnetting can create multiple logical ONS 15454 networks within a single Class A, B, or C IP network. If you do not subnet, you will only be able to use one network from your Class A, B, or C network. • Different IP functions and protocols can be used to achieve specific network goals. For example, Proxy Address Resolution Protocol (ARP) enables one LAN-connected ONS 15454 to serve as a gateway for ONS 15454s that are not connected to the LAN. • Static routes can be created to enable connections among multiple CTC sessions with ONS 15454s that reside on the same subnet. • ONS 15454s can be connected to Open Shortest Path First (OSPF) networks so that ONS 15454 network information is automatically communicated across multiple LANs and WANs. • The ONS 15454 SOCKS (network proxy protocol) proxy server can control the visibility and accessibility between CTC computers and ONS 15454 element nodes. 13.2 IP Addressing Scenarios ONS 15454 IP addressing generally has eight common scenarios or configurations. Use the scenarios as building blocks for more complex network configurations. Table 13-1 provides a general list of items to check when setting up ONS 15454 nodes in IP networks. Table 13-1 General ONS 15454 IP Troubleshooting Checklist Item What to Check Link integrity Verify that link integrity exists between: • CTC computer and network hub/switch • ONS 15454s (backplane wire-wrap pins or RJ-45 port) and network hub/switch • Router ports and hub/switch ports ONS 15454 hub/switch ports If connectivity problems occur, set the hub or switch port that is connected to the ONS 15454 to 10 Mbps half-duplex. Ping Ping the node to test connections between computers and ONS 15454s. IP addresses/subnet masks Verify that ONS 15454 IP addresses and subnet masks are set up correctly. Optical connectivity Verify that ONS 15454 optical trunk (span) ports are in service and that a DCC is enabled on each trunk port. The TCC2P card secure mode option allows two IP addresses to be provisioned for the node: one for the backplane LAN port and one for the TCC2P LAN (TCP/IP) port. Secure mode IP addressing examples are provided in the “13.2.9 IP Scenario 9: IP Addressing with Secure Mode Enabled” section on page 13-20. IP addresses shown in the other scenarios assume that secure mode is not enabled. If secure mode is enabled, the IP addresses shown in the examples apply to the backplane LAN port. See the “13.2.9 IP Scenario 9: IP Addressing with Secure Mode Enabled” section on page 13-20 for information about secure mode, repeater (single IP address) mode, and configuration locks. Cisco ONS 15454 Reference Manual, R8.5.x 13-2 78-18106-01 Chapter 13 Management Network Connectivity 13.2.1 IP Scenario 1: CTC and ONS 15454s on Same Subnet 13.2.1 IP Scenario 1: CTC and ONS 15454s on Same Subnet IP Scenario 1 shows a basic ONS 15454 LAN configuration (Figure 13-1). The ONS 15454s and CTC computer reside on the same subnet. All ONS 15454s connect to LAN A, and all ONS 15454s have DCC connections. Figure 13-1 IP Scenario 1: CTC and ONS 15454s on Same Subnet CTC Workstation IP Address 192.168.1.100 Subnet Mask 255.255.255.0 Default Gateway = N/A Host Routes = N/A LAN A ONS 15454 #2 IP Address 192.168.1.20 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A ONS 15454 #1 IP Address 192.168.1.10 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A ONS 15454 #3 IP Address 192.168.1.30 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A 33157 SONET RING 13.2.2 IP Scenario 2: CTC and ONS 15454 Nodes Connected to a Router In IP Scenario 2 the CTC computer resides on a subnet (192.168.1.0) and attaches to LAN A (Figure 13-2). The ONS 15454s reside on a different subnet (192.168.2.0) and attach to LAN B. A router connects LAN A to LAN B. The IP address of router interface A is set to LAN A (192.168.1.1), and the IP address of router interface B is set to LAN B (192.168.2.1). On the CTC computer, the default gateway is set to router interface A. If the LAN uses Dynamic Host Configuration Protocol (DHCP), the default gateway and IP address are assigned automatically. In the Figure 13-2 example, a DHCP server is not available. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-3 Chapter 13 Management Network Connectivity 13.2.3 IP Scenario 3: Using Proxy ARP to Enable an ONS 15454 Gateway Figure 13-2 IP Scenario 2: CTC and ONS 15454 Nodes Connected to a Router LAN A Int "A" CTC Workstation IP Address 192.168.1.100 Subnet Mask 255.255.255.0 Default Gateway = 192.168.1.1 Host Routes = N/A Int "B" Router IP Address of interface “A” to LAN “A” 192.168.1.1 IP Address of interface “B” to LAN “B” 192.168.2.1 Subnet Mask 255.255.255.0 Default Router = N/A Host Routes = N/A LAN B ONS 15454 #2 IP Address 192.168.2.20 Subnet Mask 255.255.255.0 Default Router = 192.168.2.1 Static Routes = N/A ONS 15454 #1 IP Address 192.168.2.10 Subnet Mask 255.255.255.0 Default Router = 192.168.2.1 Static Routes = N/A ONS 15454 #3 IP Address 192.168.2.30 Subnet Mask 255.255.255.0 Default Router = 192.168.2.1 Static Routes = N/A 33158 SONET RING 13.2.3 IP Scenario 3: Using Proxy ARP to Enable an ONS 15454 Gateway ARP matches higher-level IP addresses to the physical addresses of the destination host. It uses a lookup table (called ARP cache) to perform the translation. When the address is not found in the ARP cache, a broadcast is sent out on the network with a special format called the ARP request. If one of the machines on the network recognizes its own IP address in the request, it sends an ARP reply back to the requesting host. The reply contains the physical hardware address of the receiving host. The requesting host stores this address in its ARP cache so that all subsequent datagrams (packets) to this destination IP address can be translated to a physical address. Proxy ARP enables one LAN-connected ONS 15454 to respond to the ARP request for ONS 15454s not connected to the LAN. (ONS 15454 proxy ARP requires no user configuration.) For this to occur, the DCC-connected ONS 15454s must reside on the same subnet. When a LAN device sends an ARP request to an ONS 15454 that is not connected to the LAN, the gateway ONS 15454 returns its MAC address to the LAN device. The LAN device then sends the datagram for the remote ONS 15454 to the MAC address of the proxy ONS 15454. The proxy ONS 15454 uses its routing table to forward the datagram to the non-LAN ONS 15454. Cisco ONS 15454 Reference Manual, R8.5.x 13-4 78-18106-01 Chapter 13 Management Network Connectivity 13.2.3 IP Scenario 3: Using Proxy ARP to Enable an ONS 15454 Gateway IP Scenario 3 is similar to IP Scenario 1, but only one ONS 15454 (1) connects to the LAN (Figure 13-3). Two ONS 15454s (2 and 3) connect to ONS 15454 1 through the SONET DCC. Because all three ONS 15454s are on the same subnet, proxy ARP enables ONS 15454 1 to serve as a gateway for ONS 15454 2 and 3. Note This scenario assumes all CTC connections are to Node 1. If you connect a laptop to either ONS 15454 2 or 3, network partitioning occurs; neither the laptop nor the CTC computer can see all nodes. If you want laptops to connect directly to end network elements, you must create static routes (see “13.2.5 IP Scenario 5: Using Static Routes to Connect to LANs” section on page 13-7) or enable the ONS 15454 SOCKS proxy server (see “13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server” section on page 13-12). Figure 13-3 IP Scenario 3: Using Proxy ARP CTC Workstation IP Address 192.168.1.100 Subnet Mark at CTC Workstation 255.255.255.0 Default Gateway = N/A LAN A ONS 15454 #1 IP Address 192.168.1.10 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A SONET RING ONS 15454 #2 IP Address 192.168.1.20 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A ONS 15454 #3 IP Address 192.168.1.30 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A You can also use proxy ARP to communicate with hosts attached to the craft Ethernet ports of DCC-connected nodes (Figure 13-4). The node with an attached host must have a static route to the host. Static routes are propagated to all DCC peers using OSPF. The existing proxy ARP node is the gateway for additional hosts. Each node examines its routing table for routes to hosts that are not connected to the DCC network but are within the subnet. The existing proxy server replies to ARP requests for these additional hosts with the node MAC address. The existence of the host route in the routing table ensures that the IP packets addressed to the additional hosts are routed properly. Other than establishing a static route between a node and an additional host, no provisioning is necessary. The following restrictions apply: • Only one node acts as the proxy ARP server for any given additional host. • A node cannot be the proxy ARP server for a host connected to its Ethernet port. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-5 Chapter 13 Management Network Connectivity 13.2.4 IP Scenario 4: Default Gateway on a CTC Computer In Figure 13-4, Node 1 announces to Node 2 and 3 that it can reach the CTC host. Similarly, Node 3 announces that it can reach the ONS 152xx. The ONS 152xx is shown as an example; any network element (NE) can be set up as an additional host. Figure 13-4 IP Scenario 3: Using Proxy ARP with Static Routing CTC Workstation IP Address 192.168.1.100 Subnet Mark at CTC Workstation 255.255.255.0 Default Gateway = N/A LAN A ONS 15454 #1 IP Address 192.168.1.10 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = Destination 192.168.1.100 Mask 255.255.255.255 Next Hop 192.168.1.10 ONS 15454 #2 IP Address 192.168.1.20 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A ONS 152xx IP Address 192.168.1.31 Subnet Mask 255.255.255.0 ONS 15454 #3 IP Address 192.168.1.30 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = Destination 192.168.1.31 Mask 255.255.255.255 Next Hop 192.168.1.30 96984 SONET RING 13.2.4 IP Scenario 4: Default Gateway on a CTC Computer IP Scenario 4 is similar to IP Scenario 3, but Nodes 2 and 3 reside on different subnets, 192.168.2.0 and 192.168.3.0, respectively (Figure 13-5). Node 1 and the CTC computer are on subnet 192.168.1.0. Proxy ARP is not used because the network includes different subnets. For the CTC computer to communicate with Nodes 2 and 3, Node 1 is entered as the default gateway on the CTC computer. Cisco ONS 15454 Reference Manual, R8.5.x 13-6 78-18106-01 Chapter 13 Management Network Connectivity 13.2.5 IP Scenario 5: Using Static Routes to Connect to LANs Figure 13-5 IP Scenario 4: Default Gateway on a CTC Computer CTC Workstation IP Address 192.168.1.100 Subnet Mask at CTC Workstation 255.255.255.0 Default Gateway = 192.168.1.10 Host Routes = N/A LAN A ONS 15454 #1 IP Address 192.168.1.10 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A ONS 15454 #2 IP Address 192.168.2.20 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A ONS 15454 #3 IP Address 192.168.3.30 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A 33160 SONET RING 13.2.5 IP Scenario 5: Using Static Routes to Connect to LANs Static routes are used for two purposes: • To connect ONS 15454s to CTC sessions on one subnet connected by a router to ONS 15454s residing on another subnet. (These static routes are not needed if OSPF is enabled. “13.2.6 IP Scenario 6: Using OSPF” section on page 13-10 shows an OSPF example.) • To enable multiple CTC sessions among ONS 15454s residing on the same subnet. In Figure 13-6, one CTC residing on subnet 192.168.1.0 connects to a router through interface A. (The router is not set up with OSPF.) ONS 15454s residing on different subnets are connected through Node 1 to the router through interface B. Because Nodes 2 and 3 are on different subnets, proxy ARP does not enable Node 1 as a gateway. To connect to the CTC computer on LAN A (subnet 192.168.1.0), you must create a static route on Node 1. You must also manually add static routes between the CTC computer on LAN A and Nodes 2 and 3 because these nodes are on different subnets. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-7 Chapter 13 Management Network Connectivity 13.2.5 IP Scenario 5: Using Static Routes to Connect to LANs Figure 13-6 IP Scenario 5: Static Route With One CTC Computer Used as a Destination Router IP Address of interface ”A” to LAN “A” 192.168.1.1 IP Address of interface “B” to LAN “B” 192.168.2.1 Subnet Mask 255.255.255.0 Static Routes Destination 192.168.3.0 Destination 192.168.4.0 Mask 255.255.255.0 Mask 255.255.255.0 Next Hop 192.168.2.10 Next Hop 192.168.2.10 LAN A Int "A" CTC Workstation IP Address 192.168.1.100 Subnet Mask 255.255.255.0 Default Gateway = 192.168.1.1 Host Routes = N/A Int "B" LAN B ONS 15454 #1 IP Address 192.168.2.10 Subnet Mask 255.255.255.0 Default Router = 192.168.2.1 Static Routes Destination 192.168.1.0 Mask 255.255.255.0 Next Hop 192.168.2.1 Cost = 2 ONS 15454 #2 IP Address 192.168.3.20 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A ONS 15454 #3 IP Address 192.168.4.30 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A 33162 SONET RING The destination and subnet mask entries control access to the ONS 15454s: • If a single CTC computer is connected to a router, enter the complete CTC “host route” IP address as the destination with a subnet mask of 255.255.255.255. • If CTC computers on a subnet are connected to a router, enter the destination subnet (in this example, 192.168.1.0) and a subnet mask of 255.255.255.0. • If all CTC computers are connected to a router, enter a destination of 0.0.0.0 and a subnet mask of 0.0.0.0. Figure 13-7 shows an example. The IP address of router interface B is entered as the next hop, and the cost (number of hops from source to destination) is 2. You must manually add static routes between the CTC computers on LAN A, B, and C and Nodes 2 and 3 because these nodes are on different subnets. Cisco ONS 15454 Reference Manual, R8.5.x 13-8 78-18106-01 Chapter 13 Management Network Connectivity 13.2.5 IP Scenario 5: Using Static Routes to Connect to LANs Figure 13-7 IP Scenario 5: Static Route With Multiple LAN Destinations LAN D Router #3: IP Address of the interface connected to LAN-C = 192.168.5.10 IP Address of the interface connected to LAN-D = 192.168.6.1 Subnet Mask = 255.255.255.0 Static Routes: Destination = 192.168.0.0 Destination = 192.168.4.0 Mask = 255.255.255.0 Mask = 255.255.255.0 Next Hop = 192.168.5.1 Next Hop = 192.168.5.1 LAN C Router #2: IP Address of the interface connected to LAN-A = 192.168.1.10 IP Address of the interface connected to LAN-C = 192.168.5.1 Subnet Mask = 255.255.255.0 Static Routes: Destination = 192.168.0.0 Destination = 192.168.4.0 Mask = 255.255.255.0 Mask = 255.255.255.0 Next Hop = 192.168.1.1 Next Hop = 192.168.5.1 LAN A CTC Workstation IP Address 192.168.1.100 Subnet Mask 255.255.255.0 Default Gateway = 192.168.1.1 Host Routes = N/A Int "A" Router #1 IP Address of interface ”A” to LAN “A” 192.168.1.1 IP Address of interface “B” to LAN “B” 192.168.2.1 Subnet Mask 255.255.255.0 Destination = 192.168.0.0 Destination = 192.168.4.0 Mask = 255.255.255.0 Mask = 255.255.255.0 Next Hop = 192.168.2.10 Next Hop = 192.168.5.1 Int "B" LAN B ONS 15454 #1 IP Address 192.168.2.10 Subnet Mask 255.255.255.0 Default Router = 192.168.2.1 Static Routes Destination 0.0.0.0 Mask 0.0.0.0 Next Hop 192.168.2.1 Cost = 2 SONET RING ONS 15454 #3 IP Address 192.168.4.30 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A 55251 ONS 15454 #2 IP Address 192.168.3.20 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-9 Chapter 13 Management Network Connectivity 13.2.6 IP Scenario 6: Using OSPF 13.2.6 IP Scenario 6: Using OSPF Open Shortest Path First (OSPF) is a link state Internet routing protocol. Link state protocols use a “hello protocol” to monitor their links with adjacent routers and to test the status of their links to their neighbors. Link state protocols advertise their directly connected networks and their active links. Each link state router captures the link state “advertisements” and puts them together to create a topology of the entire network or area. From this database, the router calculates a routing table by constructing a shortest path tree. Routes are recalculated when topology changes occur. ONS 15454s use the OSPF protocol in internal ONS 15454 networks for node discovery, circuit routing, and node management. You can enable OSPF on the ONS 15454s so that the ONS 15454 topology is sent to OSPF routers on a LAN. Advertising the ONS 15454 network topology to LAN routers eliminates the need to manually enter static routes for ONS 15454 subnetworks. Figure 13-8 shows a network enabled for OSPF. Figure 13-9 shows the same network without OSPF. Static routes must be manually added to the router for CTC computers on LAN A to communicate with Nodes 2 and 3 because these nodes reside on different subnets. OSPF divides networks into smaller regions, called areas. An area is a collection of networked end systems, routers, and transmission facilities organized by traffic patterns. Each OSPF area has a unique ID number, known as the area ID. Every OSPF network has one backbone area called “area 0.” All other OSPF areas must connect to area 0. When you enable an ONS 15454 OSPF topology for advertising to an OSPF network, you must assign an OSPF area ID in decimal format to the ONS 15454 network. Coordinate the area ID number assignment with your LAN administrator. All DCC-connected ONS 15454s should be assigned the same OSPF area ID. Cisco ONS 15454 Reference Manual, R8.5.x 13-10 78-18106-01 Chapter 13 Management Network Connectivity 13.2.6 IP Scenario 6: Using OSPF Figure 13-8 IP Scenario 6: OSPF Enabled Router IP Address of interface “A” to LAN A 192.168.1.1 IP Address of interface “B” to LAN B 192.168.2.1 Subnet Mask 255.255.255.0 LAN A Int "A" CTC Workstation IP Address 192.168.1.100 Subnet Mask 255.255.255.0 Default Gateway = 192.168.1.1 Host Routes = N/A Int "B" LAN B ONS 15454 #1 IP Address 192.168.2.10 Subnet Mask 255.255.255.0 Default Router = 192.168.2.1 Static Routes = N/A SONET RING ONS 15454 #3 IP Address 192.168.4.30 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A 55250 ONS 15454 #2 IP Address 192.168.3.20 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-11 Chapter 13 Management Network Connectivity 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server Figure 13-9 IP Scenario 6: OSPF Not Enabled LAN A Int "A" CTC Workstation IP Address 192.168.1.100 Subnet Mask 255.255.255.0 Default Gateway = 192.168.1.1 Host Routes = N/A Router IP Address of interface “A” to LAN A 192.168.1.1 IP Address of interface “B” to LAN B 192.168.2.1 Subnet Mask 255.255.255.0 Static Routes = Destination 192.168.3.20 Next Hop 192.168.2.10 Destination 192.168.4.30 Next Hop 192.168.2.10 Int "B" LAN B ONS 15454 #1 IP Address 192.168.2.10 Subnet Mask 255.255.255.0 Default Router = 192.168.2.1 Static Routes Destination = 192.168.1.100 Mask = 255.255.255.255 Next Hop = 192.168.2.1 Cost = 2 ONS 15454 #2 IP Address 192.168.3.20 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A ONS 15454 #3 IP Address 192.168.4.30 Subnet Mask 255.255.255.0 Default Router = N/A Static Routes = N/A 33161 SONET RING 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server The ONS 15454 SOCKS proxy is an application that allows an ONS 15454 node to serve as an internal gateway between a private enterprise network and the ONS 15454 network. (SOCKS is a standard proxy protocol for IP-based applications developed by the Internet Engineering Task Force.) Access is allowed from the private network to the ONS 15454 network, but access is denied from the ONS 15454 network to the private network. For example, you can set up a network so that field technicians and network operations center (NOC) personnel can both access the same ONS 15454s while preventing the field technicians from accessing the NOC LAN. To do this, one ONS 15454 is provisioned as a gateway network element (GNE) and the other ONS 15454s are provisioned as end network elements (ENEs). The GNE ONS 15454 tunnels connections between CTC computers and ENE ONS 15454s, providing management capability while preventing access for non-ONS 15454 management purposes. Cisco ONS 15454 Reference Manual, R8.5.x 13-12 78-18106-01 Chapter 13 Management Network Connectivity 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server The ONS 15454 gateway setting performs the following tasks: • Isolates DCC IP traffic from Ethernet (craft port) traffic and accepts packets based on filtering rules. The filtering rules (see Table 13-3 on page 13-17 and Table 13-4 on page 13-18) depend on whether the packet arrives at the ONS 15454 DCC or the TCC2/TCC2P Ethernet interface. • Processes Simple Network Time Protocol (SNTP) and Network Time Protocol (NTP) requests. ONS 15454 ENEs can derive time-of-day from an SNTP/NTP LAN server through the GNE ONS 15454. • Processes Simple Network Management Protocol version 1 (SNMPv1) traps. The GNE ONS 15454 receives SNMPv1 traps from the ENE ONS 15454s and forwards or relays the traps to SNMPv1 trap destinations or ONS 15454 SNMP relay nodes. The ONS 15454 SOCKS proxy server is provisioned using the Enable SOCKS proxy server on port check box on the Provisioning > Network > General tab (Figure 13-10). Figure 13-10 SOCKS Proxy Server Gateway Settings If checked, the ONS 15454 serves as a proxy for connections between CTC clients and ONS 15454s that are DCC-connected to the proxy ONS 15454. The CTC client establishes connections to DCC-connected nodes through the proxy node. The CTC client can connect to nodes that it cannot directly reach from the host on which it runs. If not selected, the node does not proxy for any CTC clients, although any established proxy connections continue until the CTC client exits. In addition, you can set the SOCKS proxy server as an ENE or a GNE: Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-13 Chapter 13 Management Network Connectivity 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server • External Network Element (ENE)—If set as an ENE, the ONS 15454 neither installs nor advertises default or static routes. CTC computers can communicate with the ONS 15454 using the TCC2/TCC2P craft port, but they cannot communicate directly with any other DCC-connected ONS 15454. In addition, firewall is enabled, which means that the node prevents IP traffic from being routed between the DCC and the LAN port. The ONS 15454 can communicate with machines connected to the LAN port or connected through the DCC. However, the DCC-connected machines cannot communicate with the LAN-connected machines, and the LAN-connected machines cannot communicate with the DCC-connected machines. A CTC client using the LAN to connect to the firewall-enabled node can use the proxy capability to manage the DCC-connected nodes that would otherwise be unreachable. A CTC client connected to a DCC-connected node can only manage other DCC-connected nodes and the firewall itself. • Gateway Network Element (GNE)—If set as a GNE, the CTC computer is visible to other DCC-connected nodes and firewall is enabled. • Proxy-only—If Proxy-only is selected, firewall is not enabled. CTC can communicate with any other DCC-connected ONS 15454s. Note If you launch CTC against a node through a Network Address Translation (NAT) or Port Address Translation (PAT) router and that node does not have proxy enabled, your CTC session starts and initially appears to be fine. However, CTC never receives alarm updates and disconnects and reconnects every two minutes. If the proxy is accidentally disabled, it is still possible to enable the proxy during a reconnect cycle and recover your ability to manage the node, even through a NAT/PAT firewall. Note ENEs that belong to different private subnetworks do not need to have unique IP addresses. Two ENEs that are connected to different GNEs can have the same IP address. However, ENEs that connect to the same GNE must always have unique IP addresses. Figure 13-11 shows an ONS 15454 SOCKS proxy server implementation. A GNE ONS 15454 is connected to a central office LAN and to ENE ONS 15454s. The central office LAN is connected to a NOC LAN, which has CTC computers. Both the NOC CTC computer and the craft technicians must be able to access the ONS 15454 ENEs. However, the craft technicians must be prevented from accessing or seeing the NOC or central office LANs. In the example, the ONS 15454 GNE is assigned an IP address within the central office LAN and is physically connected to the LAN through its LAN port. ONS 15454 ENEs are assigned IP addresses that are outside the central office LAN and are given private network IP addresses. If the ONS 15454 ENEs are collocated, the craft LAN ports could be connected to a hub. However, the hub should have no other network connections. Cisco ONS 15454 Reference Manual, R8.5.x 13-14 78-18106-01 Chapter 13 Management Network Connectivity 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server Figure 13-11 IP Scenario 7: ONS 15454 SOCKS Proxy Server with GNE and ENEs on the Same Subnet Remote CTC 10.10.20.10 10.10.20.0/24 Interface 0/0 10.10.20.1 Router A Interface 0/1 10.10.10.1 10.10.10.0/24 ONS 15454 GNE 10.10.10.100/24 ONS 15454 ENE 10.10.10.150/24 ONS 15454 ENE 10.10.10.250/24 ONS 15454 ENE 10.10.10.200/24 SONET 71673 Ethernet Local/Craft CTC 10.10.10.50 Table 13-2 shows recommended settings for ONS 15454 GNEs and ENEs in the configuration shown in Figure 13-11. Table 13-2 ONS 15454 Gateway and End NE Settings Setting ONS 15454 Gateway NE ONS 15454 End NE OSPF Off Off SNTP server (if used) SNTP server IP address Set to ONS 15454 GNE IP address SNMP (if used) Set SNMPv1 trap destinations to ONS 15454 GNE, port 391 SNMPv1 trap destinations Figure 13-12 shows the same SOCKS proxy server implementation with ONS 15454 ENEs on different subnets. Figure 13-13 on page 13-17 shows the implementation with ONS 15454 ENEs in multiple rings. In each example, ONS 15454 GNEs and ENEs are provisioned with the settings shown in Table 13-2. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-15 Chapter 13 Management Network Connectivity 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server Figure 13-12 IP Scenario 7: ONS 15454 SOCKS Proxy Server with GNE and ENEs on Different Subnets Remote CTC 10.10.20.10 10.10.20.0/24 Interface 0/0 10.10.20.1 Router A Interface 0/1 10.10.10.1 10.10.10.0/24 ONS 15454 GNE 10.10.10.100/24 ONS 15454 ENE 192.168.10.150/24 ONS 15454 ENE 192.168.10.250/24 ONS 15454 ENE 192.168.10.200/24 SONET 71674 Ethernet Local/Craft CTC 192.168.10.20 Cisco ONS 15454 Reference Manual, R8.5.x 13-16 78-18106-01 Chapter 13 Management Network Connectivity 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server Figure 13-13 IP Scenario 7: ONS 15454 SOCKS Proxy Server With ENEs on Multiple Rings Remote CTC 10.10.20.10 10.10.20.0/24 Interface 0/0 10.10.20.1 Router A Interface 0/1 10.10.10.1 10.10.10.0/24 ONS 15454 GNE 10.10.10.100/24 ONS 15454 ENE 192.168.10.150/24 ONS 15454 GNE 10.10.10.200/24 ONS 15454 ENE 192.168.10.250/24 ONS 15454 ENE 192.168.60.150/24 ONS 15454 ENE 192.168.10.200/24 ONS 15454 ENE 192.168.80.250/24 ONS 15454 ENE 192.168.70.200/24 SONET 71675 Ethernet Table 13-3 shows the rules that the ONS 15454 follows to filter packets for the firewall when nodes are configured as ENEs and GNEs. Table 13-3 SOCKS Proxy Server Firewall Filtering Rules Packets Arriving At: TCC2/TCC2P Ethernet interface DCC interface Are Accepted if the Destination IP Address is: • The ONS 15454 node itself • The ONS 15454 node’s subnet broadcast address • Within the 224.0.0.0/8 network (reserved network used for standard multicast messages) • Subnet mask = 255.255.255.255 • The ONS 15454 node itself • Any destination connected through another DCC interface • Within the 224.0.0.0/8 network If the packet is addressed to the ONS 15454 node, additional rules, shown in Table 13-4, are applied. Rejected packets are silently discarded. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-17 Chapter 13 Management Network Connectivity 13.2.8 IP Scenario 8: Dual GNEs on a Subnet Table 13-4 SOCKS Proxy Server Firewall Filtering Rules When Packet Addressed to the ONS 15454 Packets Arriving At Accepts Rejects 1 TCC2/TCC2P Ethernet interface • All UDP packets except those in the Rejected column • UDP packets addressed to the SNMP trap relay port (391) DCC interface • All UDP packets • • 2 All TCP protocols except packets addressed to the Telnet and SOCKS proxy server ports TCP packets addressed to the Telnet port • TCP packets addressed to the SOCKS proxy server port • OSPF packets • • ICMP3 packets All packets other than UDP, TCP, OSPF, ICMP 1. UDP = User Datagram Protocol 2. TCP = Transmission Control Protocol 3. ICMP = Internet Control Message Protocol If you implement the SOCKS proxy server, note that all DCC-connected ONS 15454s on the same Ethernet segment must have the same gateway setting. Mixed values produce unpredictable results, and might leave some nodes unreachable through the shared Ethernet segment. If nodes become unreachable, correct the setting with one of the following actions: • Disconnect the craft computer from the unreachable ONS 15454. Connect to the ONS 15454 through another network ONS 15454 that has a DCC connection to the unreachable ONS 15454. • Disconnect all DCCs to the node by disabling them on neighboring nodes. Connect a CTC computer directly to the ONS 15454 and change its provisioning. 13.2.8 IP Scenario 8: Dual GNEs on a Subnet The ONS 15454 provides GNE load balancing, which allows CTC to reach ENEs over multiple GNEs without the ENEs being advertised over OSPF. This feature allows a network to quickly recover from the loss of a GNE, even if the GNE is on a different subnet. If a GNE fails, all connections through that GNE fail. CTC disconnects from the failed GNE and from all ENEs for which the GNE was a proxy, and then reconnects through the remaining GNEs. GNE load balancing reduces the dependency on the launch GNE and DCC bandwidth, both of which enhance CTC performance. Figure 13-14 shows a network with dual GNEs on the same subnet. Cisco ONS 15454 Reference Manual, R8.5.x 13-18 78-18106-01 Chapter 13 Management Network Connectivity 13.2.8 IP Scenario 8: Dual GNEs on a Subnet Figure 13-14 IP Scenario 8: Dual GNEs on the Same Subnet Remote CTC 10.10.20.10 10.10.20.0/24 Interface 0/0 10.10.20.1 Router A Interface 0/1 10.10.10.1 ONS 15454 GNE 10.10.10.100/24 ONS 15454 GNE 10.10.10.150/24 ONS 15454 ENE 10.10.10.250/24 ONS 15454 ENE 10.10.10.200/24 Ethernet Local/Craft CTC 192.168.20.20 SONET 115258 10.10.10.0/24 Figure 13-15 shows a network with dual GNEs on different subnets. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-19 Chapter 13 Management Network Connectivity 13.2.9 IP Scenario 9: IP Addressing with Secure Mode Enabled Figure 13-15 IP Scenario 8: Dual GNEs on Different Subnets Remote CTC 10.10.20.10 10.10.20.0/24 Interface 0/0 10.10.20.1 Router A Interface 0/2 10.20.10.1 10.10.10.0/24 10.20.10.0/24 ONS 15454 GNE 10.20.10.100/24 ONS 15454 GNE 10.10.10.100/24 ONS 15454 ENE 192.168.10.200/24 ONS 15454 ENE 192.168.10.250/24 Ethernet Local/Craft CTC 192.168.20.20 SONET 115259 Interface 0/1 10.10.10.1 13.2.9 IP Scenario 9: IP Addressing with Secure Mode Enabled The TCC2 card and TCC2P card both default to nonsecure mode. In this mode, the front and back Ethernet (LAN) ports share a single MAC address and IP address. TCC2P cards allow you to place a node in secure mode, which prevents a front-access craft port user from accessing the LAN through the backplane port. Secure mode can be locked, which prevents the mode from being altered. To place a node in secure mode or to lock secure node, refer to the “Change Node Settings” chapter in the Cisco ONS 15454 Procedure Guide. 13.2.9.1 Secure Mode Behavior Changing a TCC2P node from repeater mode to secure mode allows you to provision two IP addresses for the ONS 15454 and causes the node to assign the ports different MAC addresses. In secure mode, one IP address is provisioned for the ONS 15454 backplane LAN port, and the other IP address is provisioned for the TCC2P Ethernet port. Both addresses reside on different subnets, providing an additional layer of separation between the craft access port and the ONS 15454 LAN. If secure mode is Cisco ONS 15454 Reference Manual, R8.5.x 13-20 78-18106-01 Chapter 13 Management Network Connectivity 13.2.9 IP Scenario 9: IP Addressing with Secure Mode Enabled enabled, the IP addresses provisioned for both TCC2P TCP/IP LAN ports must follow general IP addressing guidelines and must reside on different subnets from each other and the default router IP address. In secure mode, the IP address assigned to the front LAN (Ethernet) port becomes a private address, while the backplane connects the node to an Operations Support System (OSS) through a central office LAN or private enterprise network. A superuser can configure the node to hide or reveal the backplane's LAN IP address in CTC, the routing table, or autonomous message reports. In nonsecure mode, a node can be a GNE or ENE. Placing the node into secure mode automatically turns on SOCKS proxy and defaults the node to GNE status. However, the node can be changed back to an ENE. In nonsecure mode, an ENE’s SOCKS proxy can be disabled—effectively isolating the node beyond the LAN firewall—but it cannot be disabled in secure mode.To change a node’s GNE or ENE status and disable the SOCKS proxy, refer to the “Turn Up a Node” chapter in the Cisco ONS 15454 Procedure Guide. Caution Enabling secure mode causes the TCC2P card to reboot; a TCC2P card reboot affects traffic. Note The secure mode option does not appear in CTC if TCC2 cards are installed. If one TCC2 and one TCC2P card are installed in a node, secure mode will appear in CTC but it cannot be modified. Note If both front and backplane access ports are disabled in an ENE and the node is isolated from DCC communication (due to user provisioning or network faults), the front and backplane ports are automatically reenabled. Figure 13-16 on page 13-22 shows an example of secure-mode ONS 15454 nodes with front-access Ethernet port addresses that reside on the same subnet. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-21 Chapter 13 Management Network Connectivity 13.2.9 IP Scenario 9: IP Addressing with Secure Mode Enabled Figure 13-16 IP Scenario 9: ONS 15454 GNE and ENEs on the Same Subnet with Secure Mode Enabled Remote CTC 10.10.20.10 10.10.20.0/24 Interface 0/0 10.10.20.1 Router A Interface 0/1 10.10.10.1 ONS 15454 GNE Backplane - 10.10.10.100/24 TCC2P - 176.20.20.40/24 ONS 15454 ENE 10.10.10.150/24 - Backplane 176.20.20.10/24 - TCC2P ONS 15454 ENE Backplane - 10.10.10.250/24 TCC2P - 176.20.20.30/24 ONS 15454 ENE 10.10.10.200/24 - Backplane 176.20.20.20/24 - TCC2P Ethernet Local/Craft CTC 176.20.20.50 SONET 124679 10.10.10.0/24 Figure 13-17 shows an example of ONS 15454 nodes connected to a router with secure mode enabled. In each example, the node’s TCC2P port address (node address) resides on a different subnet from the node backplane addresses. Cisco ONS 15454 Reference Manual, R8.5.x 13-22 78-18106-01 Chapter 13 Management Network Connectivity 13.2.9 IP Scenario 9: IP Addressing with Secure Mode Enabled Figure 13-17 IP Scenario 9: ONS 15454 GNE and ENEs on Different Subnets with Secure Mode Enabled Remote CTC 10.10.20.10 10.10.20.0/24 Interface 0/0 10.10.20.1 Router A Interface 0/1 10.10.10.1 10.10.10.0/24 ONS 15454 GNE Backplane - 10.10.10.100/24 TCC2P - 176.20.20.40/24 ONS 15454 ENE 192.168.10.150/24 - Backplane 176.20.20.10/24 - TCC2P ONS 15454 ENE Backplane - 192.168.10.250/24 TCC2P - 176.20.20.30/24 ONS 15454 ENE 192.168.10.200/24 - Backplane 176.20.20.20/24 - TCC2P SONET 71674 Ethernet Local/Craft CTC 176.20.20.50 13.2.9.2 Secure Node Locked and Unlocked Behavior Secure mode can operate on a node in either locked or unlocked mode. By default, secure mode’s status is unlocked; only a superuser can convert it to locked mode. Doing so permanently changes the hardware configuration on the active and standby TCC2P cards as well as the chassis. Locked mode must be used carefully because the cards and shelf retain their locked status even if separated from each other. For example, if a node is in secure, locked mode and you perform a card pull on its standby TCC2P, then insert that as the active card into another node, the secure, locked mode is written to the new node’s chassis and standby TCC2P. If you perform a card pull on a secure, locked node’s active and standby TCC2Ps and insert both of them into a chassis that previously was in unlocked mode, the node becomes locked. When it is secure and locked, a node’s configuration, Ethernet port status, its secure mode, and the locked status cannot be changed by any network user— including a superuser. To have a secure node’s lock removed, contact Cisco Technical Support to arrange a Return Material Authorization (RMA) for the chassis and for the TCC2Ps. Refer to the “Obtaining Documentation and Submitting a Service Request” section on page lii as needed. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-23 Chapter 13 Management Network Connectivity 13.3 Routing Table 13.3 Routing Table ONS 15454 routing information appears on the Maintenance > Routing Table tab. The routing table provides the following information: • Destination—Displays the IP address of the destination network or host. • Mask—Displays the subnet mask used to reach the destination host or network. • Gateway—Displays the IP address of the gateway used to reach the destination network or host. • Usage—Shows the number of times the listed route has been used. • Interface—Shows the ONS 15454 interface used to access the destination. Values are: – motfcc0—The ONS 15454 Ethernet interface, that is, the RJ-45 jack on the TCC2/TCC2P and the LAN 1 pins on the backplane – pdcc0—A DCC/OSC/GCC interface – lo0—A loopback interface Table 13-5 shows sample routing table entries for an ONS 15454. Table 13-5 Sample Routing Table Entries Entry Destination Mask Gateway Usage Interface 1 0.0.0.0 0.0.0.0 172.20.214.1 265103 motfcc0 2 172.20.214.0 255.255.255.0 172.20.214.92 0 motfcc0 3 172.20.214.92 255.255.255.255 127.0.0.1 54 lo0 4 172.20.214.93 255.255.255.255 0.0.0.0 16853 pdcc0 5 172.20.214.94 255.255.255.255 172.20.214.93 16853 pdcc0 Entry 1 shows the following: • Destination (0.0.0.0) is the default route entry. All undefined destination network or host entries on this routing table are mapped to the default route entry. • Mask (0.0.0.0) is always 0 for the default route. • Gateway (172.20.214.1) is the default gateway address. All outbound traffic that cannot be found in this routing table or is not on the node’s local subnet is sent to this gateway. • Interface (motfcc0) indicates that the ONS 15454 Ethernet interface is used to reach the gateway. Entry 2 shows the following: • Destination (172.20.214.0) is the destination network IP address. • Mask (255.255.255.0) is a 24-bit mask, meaning all addresses within the 172.20.214.0 subnet can be destinations. • Gateway (172.20.214.92) is the gateway address. All outbound traffic belonging to this network is sent to this gateway. • Interface (motfcc0) indicates that the ONS 15454 Ethernet interface is used to reach the gateway. Entry 3 shows the following: • Destination (172.20.214.92) is the destination host IP address. Cisco ONS 15454 Reference Manual, R8.5.x 13-24 78-18106-01 Chapter 13 Management Network Connectivity 13.4 External Firewalls • Mask (255.255.255.255) is a 32 bit mask, meaning that only the 172.20.214.92 address is a destination. • Gateway (127.0.0.1) is a loopback address. The host directs network traffic to itself using this address. • Interface (lo0) indicates that the local loopback interface is used to reach the gateway. Entry 4 shows the following: • Destination (172.20.214.93) is the destination host IP address. • Mask (255.255.255.255) is a 32 bit mask, meaning that only the 172.20.214.93 address is a destination. • Gateway (0.0.0.0) means the destination host is directly attached to the node. • Interface (pdcc0) indicates that a DCC interface is used to reach the destination host. Entry 5 shows a DCC-connected node that is accessible through a node that is not directly connected: • Destination (172.20.214.94) is the destination host IP address. • Mask (255.255.255.255) is a 32-bit mask, meaning that only the 172.20.214.94 address is a destination. • Gateway (172.20.214.93) indicates that the destination host is accessed through a node with IP address 172.20.214.93. • Interface (pdcc0) indicates that a DCC interface is used to reach the gateway. 13.4 External Firewalls This section provides sample access control lists (ACLs) for external firewalls. Table 13-6 lists the ports that are used by the TCC2/TCC2P card. Table 13-6 Ports Used by the TCC2/TCC2P Port Function Action1 0 Never used D 20 FTP D 21 FTP control D 22 SSH (Secure Shell) D 23 Telnet D 80 HTTP D 111 SUNRPC (Sun Remote Procedure Call) NA 161 SNMP traps destinations D 162 SNMP traps destinations D 513 rlogin D 683 CORBA IIOP2 OK 1080 Proxy server (socks) D 2001-2017 I/O card Telnet D 2018 DCC processor on active TCC2/TCC2P D Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-25 Chapter 13 Management Network Connectivity 13.4 External Firewalls Table 13-6 Ports Used by the TCC2/TCC2P (continued) Port Function Action1 2361 TL1 D 3082 Raw TL1 D 3083 TL1 D 3 5001 BLSR server port D 5002 BLSR client port D 7200 SNMP alarm input port D 9100 EQM port D 9401 TCC boot port D 9999 Flash manager D 10240-12287 Proxy client D 57790 Default TCC listener port OK 1. D = deny, NA = not applicable, OK = do not deny 2. CORBA IIOP = Common Object Request Broker Architecture Internet Inter-ORB Protocol 3. BLSR = bidirectional line switched ring The following ACL example shows a firewall configuration when the SOCKS proxy server gateway setting is not enabled. In the example, the CTC workstation's address is 192.168.10.10. and the ONS 15454 address is 10.10.10.100. The firewall is attached to the GNE, so inbound is CTC to the GNE and outbound is from the GNE to CTC. The CTC CORBA Standard constant is 683 and the TCC CORBA Default is TCC Fixed (57790). access-list access-list access-list access-list access-list access-list access-list access-list access-list access-list 100 100 100 100 100 100 100 100 100 100 remark remark permit remark remark permit remark remark permit remark access-list access-list access-list access-list workstation access-list access-list access-list 101 remark 101 remark 101 permit 101 remark (port 683) 100 remark 101 permit 101 remark *** Inbound ACL, CTC -> NE *** tcp host 192.168.10.10 host 10.10.10.100 eq www *** allows initial contact with ONS 15454 using http (port 80) *** tcp host 192.168.10.10 host 10.10.10.100 eq 57790 *** allows CTC communication with ONS 15454 GNE (port 57790) *** tcp host 192.168.10.10 host 10.10.10.100 established *** allows ACKs back from CTC to ONS 15454 GNE *** *** Outbound ACL, NE -> CTC *** tcp host 10.10.10.100 host 192.168.10.10 eq 683 *** allows alarms etc., from the 15454 (random port) to the CTC *** tcp host 10.10.10.100 host 192.168.10.10 established *** allows ACKs from the 15454 GNE to CTC *** The following ACL example shows a firewall configuration when the SOCKS proxy server gateway setting is enabled. As with the first example, the CTC workstation address is 192.168.10.10 and the ONS 15454 address is 10.10.10.100. The firewall is attached to the GNE, so inbound is CTC to the GNE and outbound is from the GNE to CTC. CTC CORBA Standard constant is 683 and the TCC CORBA Default is TCC Fixed (57790). access-list 100 remark *** Inbound ACL, CTC -> NE *** access-list 100 remark access-list 100 permit tcp host 192.168.10.10 host 10.10.10.100 eq www Cisco ONS 15454 Reference Manual, R8.5.x 13-26 78-18106-01 Chapter 13 Management Network Connectivity 13.5 Open GNE access-list access-list access-list access-list access-list 100 100 100 100 100 remark *** allows initial contact with the 15454 using http (port 80) *** remark permit tcp host 192.168.10.10 host 10.10.10.100 eq 1080 remark *** allows CTC communication with the 15454 GNE (port 1080) *** remark access-list access-list access-list access-list 101 101 101 101 remark *** Outbound ACL, NE -> CTC *** remark permit tcp host 10.10.10.100 host 192.168.10.10 established remark *** allows ACKs from the 15454 GNE to CTC *** 13.5 Open GNE The ONS 15454 can communicate with non-ONS nodes that do not support Point-to-Point Protocol (PPP) vendor extensions or OSPF type 10 opaque link-state advertisements (LSA), both of which are necessary for automatic node and link discovery. An open GNE configuration allows the DCC-based network to function as an IP network for non-ONS nodes. To configure an open GNE network, you can provision SDCC, LDCC, and GCC terminations to include a far-end, non-ONS node using either the default IP address of 0.0.0.0 or a specified IP address. You provision a far-end, non-ONS node by checking the Far End is Foreign check box during SDCC, LDCC, and GCC creation. The default 0.0.0.0 IP address allows the far-end, non-ONS node to provide the IP address; if you set an IP address other than 0.0.0.0, a link is established only if the far-end node identifies itself with that IP address, providing an extra level of security. By default, the SOCKS proxy server only allows connections to discovered ONS peers and the firewall blocks all IP traffic between the DCC network and LAN. You can, however, provision proxy tunnels to allow up to 12 additional destinations for SOCKS version 5 connections to non-ONS nodes. You can also provision firewall tunnels to allow up to 12 additional destinations for direct IP connectivity between the DCC network and the LAN. Proxy and firewall tunnels include both a source and destination subnet. The connection must originate within the source subnet and terminate within the destination subnet before either the SOCKS connection or IP packet flow is allowed. To set up proxy and firewall subnets in CTC, use the Provisioning > Network > Proxy and Firewalls subtabs. The availability of proxy and/or firewall tunnels depends on the network access settings of the node: • If the node is configured with the SOCKS proxy server enabled in GNE or ENE mode, you must set up a proxy tunnel and/or a firewall tunnel. • If the node is configured with the SOCKS proxy server enabled in proxy-only mode, you can set up proxy tunnels. Firewall tunnels are not allowed. • If the node is configured with the SOCKS proxy server disabled, neither proxy tunnels nor firewall tunnels are allowed. Figure 13-18 shows an example of a foreign node connected to the DCC network. Proxy and firewall tunnels are useful in this example because the GNE would otherwise block IP access between the PC and the foreign node. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-27 Chapter 13 Management Network Connectivity 13.5 Open GNE Figure 13-18 Proxy and Firewall Tunnels for Foreign Terminations Remote CTC 10.10.20.10 10.10.20.0/24 Interface 0/0 10.10.20.1 Router A Interface 0/1 10.10.10.1 ONS 15454 GNE 10.10.10.100/24 ONS 15454 ENE 10.10.10.150/24 ONS 15454 ENE 10.10.10.250/24 ONS 15454 ENE 10.10.10.200/24 Non-ONS node Foreign NE 130.94.122.199/28 Ethernet Local/Craft CTC 192.168.20.20 SONET 115748 10.10.10.0/24 Figure 13-19 shows a remote node connected to an ENE Ethernet port. Proxy and firewall tunnels are useful in this example because the GNE would otherwise block IP access between the PC and foreign node. This configuration also requires a firewall tunnel on the ENE. Cisco ONS 15454 Reference Manual, R8.5.x 13-28 78-18106-01 Chapter 13 Management Network Connectivity 13.6 TCP/IP and OSI Networking Figure 13-19 Foreign Node Connection to an ENE Ethernet Port Remote CTC 10.10.20.10 10.10.20.0/24 Interface 0/0 10.10.20.1 Router A Interface 0/1 10.10.10.1 ONS 15454 GNE 10.10.10.100/24 ONS 15454 ENE 10.10.10.150/24 ONS 15454 ENE 10.10.10.250/24 ONS 15454 ENE 10.10.10.200/24 Non-ONS node Foreign NE 130.94.122.199/28 Ethernet Local/Craft CTC 192.168.20.20 SONET 115749 10.10.10.0/24 13.6 TCP/IP and OSI Networking ONS 15454 DCN communication is based on the TCP/IP protocol suite. However, ONS 15454s can also be networked with equipment that uses the OSI protocol suite. While TCP/IP and OSI protocols are not directly compatible, they do have the same objectives and occupy similar layers of the OSI reference model. Table 13-7 shows the protocols and mediation processes that are involved when TCP/IP-based NEs are networked with OSI-based NEs. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-29 Chapter 13 Management Network Connectivity 13.6.1 Point-to-Point Protocol Table 13-7 OSI Model Layer 7 Application Layer 6 Presentation TCP/IP and OSI Protocols IP Protocols • TL1 • FTP • HTTP • Telnet • IIOP OSI Protocols • TARP 1 Layer 5 Session Layer 4 Transport • TCP • UDP Layer 3 Network • IP • CLNP8 • OSPF • ES-IS9 • IS-IS10 • PPP • LAP-D11 Layer 2 Data link Layer 1 Physical • PPP DCC, LAN, fiber, electrical IP-OSI Mediation • TL1 (over OSI) • T–TD4 • FT–TD5 • IP-over-CLNS 7 tunnels 2 • FTAM • ACSE3 • PST6 • Session • TP (Transport) Class 4 DCC, LAN, fiber, electrical 1. TARP = TID Address Resolution Protocol 2. FTAM = File Transfer and Access Management 3. ACSE = association-control service element 4. T–TD = TL1–Translation Device 5. FT–TD = File Transfer—Translation Device 6. PST = Presentation layer 7. CLNS = Connectionless Network Layer Service 8. CLNP = Connectionless Network Layer Protocol 9. ES-IS = End System-to-Intermediate System 10. IS-IS = Intermediate System-to-Intermediate System 11. LAP-D = Link Access Protocol on the D Channel 13.6.1 Point-to-Point Protocol PPP is a data link (Layer 2) encapsulation protocol that transports datagrams over point-to-point links. Although PPP was developed to transport IP traffic, it can carry other protocols including the OSI CLNP. PPP components used in the transport of OSI include: • High-level data link control (HDLC)—Performs the datagram encapsulation for transport across point-to-point links. • Link control protocol (LCP)—Establishes, configures, and tests the point-to-point connections. CTC automatically enables IP over PPP whenever you create an SDCC or LDCC. The SDCC or LDCC can be provisioned to support OSI over PPP. Cisco ONS 15454 Reference Manual, R8.5.x 13-30 78-18106-01 Chapter 13 Management Network Connectivity 13.6.2 Link Access Protocol on the D Channel 13.6.2 Link Access Protocol on the D Channel LAP-D is a data link protocol used in the OSI protocol stack. LAP-D is assigned when you provision an ONS 15454 SDCC as OSI-only. Provisionable LAP-D parameters include: • Transfer Service—One of the following transfer services must be assigned: – Acknowledged Information Transfer Service (AITS)—(Default) Does not exchange data until a logical connection between two LAP-D users is established. This service provides reliable data transfer, flow control, and error control mechanisms. – Unacknowledged Information Transfer Service (UITS)—Transfers frames containing user data with no acknowledgement. The service does not guarantee that the data presented by one user will be delivered to another user, nor does it inform the user if the delivery attempt fails. It does not provide any flow control or error control mechanisms. • Mode—LAP-D is set to either Network or User mode. This parameter sets the LAP-D frame command/response (C/R) value, which indicates whether the frame is a command or a response. • Maximum transmission unit (MTU)—The LAP-D N201 parameter sets the maximum number of octets in a LAP-D information frame. The range is 512 to 1500 octets. Note • The MTU must be the same size for all NEs on the network. Transmission Timers—The following LAP-D timers can be provisioned: – The T200 timer sets the timeout period for initiating retries or declaring failures. – The T203 timer provisions the maximum time between frame exchanges, that is, the trigger for transmission of the LAP-D “keep-alive” Receive Ready (RR) frames. Fixed values are assigned to the following LAP-D parameters: • Terminal Endpoint Identifier (TEI)—A fixed value of 0 is assigned. • Service Access Point Identifier (SAPI)—A fixed value of 62 is assigned. • N200 supervisory frame retransmissions—A fixed value of 3 is assigned. 13.6.3 OSI Connectionless Network Service OSI connectionless network service is implemented by using the Connectionless Network Protocol (CLNP) and Connectionless Network Service (CLNS). CLNP and CLNS are described in the ISO 8473 standard. CLNS provides network layer services to the transport layer through CLNP. CLNS does not perform connection setup or termination because paths are determined independently for each packet that is transmitted through a network. CLNS relies on transport layer protocols to perform error detection and correction. CLNP is an OSI network layer protocol that carries upper-layer data and error indications over connectionless links. CLNP provides the interface between the CLNS and upper layers. CLNP performs many of the same services for the transport layer as IP. The CLNP datagram is very similar to the IP datagram. It provides mechanisms for fragmentation (data unit identification, fragment/total length, and offset). Like IP, a checksum computed on the CLNP header verifies that the information used to process the CLNP datagram is transmitted correctly, and a lifetime control mechanism (Time to Live) limits the amount of time a datagram is allowed to remain in the system. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-31 Chapter 13 Management Network Connectivity 13.6.3 OSI Connectionless Network Service CLNP uses network service access points (NSAPs) to identify network devices. The CLNP source and destination addresses are NSAPs. In addition, CLNP uses a network element title (NET) to identify a network-entity in an end system (ES) or intermediate system (IS). NETs are allocated from the same name space as NSAP addresses. Whether an address is an NSAP address or a NET depends on the network selector value in the NSAP. The ONS 15454 supports the ISO Data Country Code (ISO-DCC) NSAP address format as specified in ISO 8348. The NSAP address is divided into an initial domain part (IDP) and a domain-specific part (DSP). NSAP fields are shown in Table 13-8. NSAP field values are in hexadecimal format. All NSAPs are editable. Shorter NSAPs can be used. However NSAPs for all NEs residing within the same OSI network area usually have the same NSAP format. Table 13-8 Field NSAP Fields Definition Description AFI Authority and format identifier Specifies the NSAP address format. The initial value is 39 for the ISO-DCC address format. IDI Initial domain identifier Specifies the country code. The initial value is 840F, the United States country code padded with an F. DFI DSP format identifier Specifies the DSP format. The initial value is 80, indicating the DSP format follows American National Standards Institute (ANSI) standards. ORG Organization Organization identifier. The initial value is 000000. IDP DSP Reserved Reserved Reserved NSAP field. The Reserved field is normally all zeros (0000). RD Routing domain Defines the routing domain. The initial value is 0000. AREA Area Identifies the OSI routing area to which the node belongs. The initial value is 0000. Cisco ONS 15454 Reference Manual, R8.5.x 13-32 78-18106-01 Chapter 13 Management Network Connectivity 13.6.3 OSI Connectionless Network Service Table 13-8 NSAP Fields (continued) Field Definition Description System System identifier The ONS 15454 system identifier is set to its IEEE 802.3 MAC address. Each ONS 15454 supports three OSI virtual routers. Each router NSAP system identifier is the ONS 15454 IEEE 802.3 MAC address + n, where n = 0 to 2. For the primary virtual router, n = 0. SEL Selector The selector field directs the protocol data units (PDUs) to the correct destination using the CLNP network layer service. Selector values supported by the ONS 15454 include: • 00—Network Entity Title (NET). Used to exchange PDUs in the ES-IS and IS-IS routing exchange protocols. (See the “13.6.4.1 End System-to-Intermediate System Protocol” section on page 13-36 and the “13.6.4.2 Intermediate System-to-Intermediate System Protocol” section on page 13-36.) • 1D—Selector for Transport Class 4 (and for FTAM and TL1 applications (Telcordia GR-253-CORE standard) • AF—Selector for the TARP protocol (Telcordia GR-253-CORE standard) • 2F—Selector for the GRE IP-over-CLNS tunnel (ITU/RFC standard) • CC—Selector for the Cisco IP-over-CLNS tunnels (Cisco specific) • E0—Selector for the OSI ping application (Cisco specific) NSELs are only advertised when the node is configured as an ES. They are not advertised when a node is configured as an IS. Tunnel NSELs are not advertised until a tunnel is created. Figure 13-20 shows the ISO-DCC NSAP address with the default values delivered with the ONS 15454. The System ID is automatically populated with the node MAC address. Figure 13-20 ISO-DCC NSAP Address Initial Domain Identifier AFI DSP Format Identifier IDI DFI Routing Domain ORG Reserved RD NSAP Selector Area System ID SEL 39.840F.80.000000.0000.0000.0000.xxxxxxxxxxxx.00 131598 Authority and Format Identifier The ONS 15454 main NSAP address is shown on the node view Provisioning > OSI > Main Setup subtab (Figure 13-21). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-33 Chapter 13 Management Network Connectivity 13.6.4 OSI Routing Figure 13-21 OSI Main Setup This address is also the Router 1 primary manual area address, which is viewed and edited on the Provisioning > OSI > Routers subtab. See the “13.6.7 OSI Virtual Routers” section on page 13-41 for information about the OSI router and manual area addresses in CTC. 13.6.4 OSI Routing OSI architecture includes ESs and ISs. The OSI routing scheme includes: • A set of routing protocols that allow ESs and ISs to collect and distribute the information necessary to determine routes. Protocols include the ES-IS and IS-IS protocols. ES-IS routing establishes connectivity and reach ability among ESs and ISs attached to the same (single) subnetwork. • A routing information base (RIB) (see containing this information, from which routes between ESs can be computed. The RIB consists of a table of entries that identify a destination (for example, an NSAP), the subnetwork over which packets should be forwarded to reach that destination, and a routing metric. The routing metric communicates characteristics of the route (such as delay properties or expected error rate) that are used to evaluate the suitability of a route compared to another route with different properties, for transporting a particular packet or class of packets. • A routing algorithm, Shortest Path First (SPF), that uses information contained in the RIB to derive routes between ESs. Cisco ONS 15454 Reference Manual, R8.5.x 13-34 78-18106-01 Chapter 13 Management Network Connectivity 13.6.4 OSI Routing In OSI networking, discovery is based on announcements. An ES uses the ES-IS protocol end system hello (ESH) message to announce its presence to ISs and ESs connected to the same network. Any ES or IS that is listening for ESHs gets a copy. ISs store the NSAP address and the corresponding subnetwork address pair in routing tables. ESs might store the address, or they might wait to be informed by ISs when they need such information. An IS composes intermediate system hello (ISH) messages to announce its configuration information to ISs and ESs that are connected to the same broadcast subnetwork. Like the ESHs, the ISH contains the addressing information for the IS (the NET and the subnetwork point-of-attachment address [SNPA]) and a holding time. ISHs might also communicate a suggested ES configuration time recommending a configuration timer to ESs. The exchange of ISHs is called neighbor greeting or initialization. Each router learns about the other routers with which they share direct connectivity. After the initialization, each router constructs a link-state packet (LSP). The LSP contains a list of the names of the IS’s neighbors and the cost to reach each of the neighbors. Routers then distribute the LSPs to all of the other routers. When all LSPs are propagated to all routers, each router has a complete map of the network topology (in the form of LSPs). Routers use the LSPs and the SPF algorithm to compute routes to every destination in the network. OSI networks are divided into areas and domains. An area is a group of contiguous networks and attached hosts that is designated as an area by a network administrator. A domain is a collection of connected areas. Routing domains provide full connectivity to all ESs within them. Routing within the same area is known as Level 1 routing. Routing between two areas is known as Level 2 routing. LSPs that are exchanged within a Level 1 area are called L1 LSPs. LSPs that are exchanged across Level 2 areas are called L2 LSPs. Figure 13-22 shows an example of Level 1 and Level 2 routing. Level 1 and Level 2 OSI Routing ES ES Area 1 Area 2 IS IS IS ES Level 2 routing Level 1 routing IS ES Level 1 routing 131597 Figure 13-22 Domain When you provision an ONS 15454 for a network with NEs that use both the TCP/IP and OSI protocol stacks, you will provision it as one of the following: • End System—The ONS 15454 performs OSI ES functions and relies upon an IS for communication with nodes that reside within its OSI area. • Intermediate System Level 1—The ONS 15454 performs OSI IS functions. It communicates with IS and ES nodes that reside within its OSI area. It depends upon an IS L1/L2 node to communicate with IS and ES nodes that reside outside its OSI area. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-35 Chapter 13 Management Network Connectivity 13.6.4 OSI Routing • Intermediate System Level 1/Level 2—The ONS 15454 performs IS functions. It communicates with IS and ES nodes that reside within its OSI area. It also communicates with IS L1/L2 nodes that reside in other OSI areas. This option should not be provisioned unless the node is connected to another IS L1/L2 node that resides in a different OSI area. The node must also be connected to all nodes within its area that are provisioned as IS L1/L2. 13.6.4.1 End System-to-Intermediate System Protocol ES-IS is an OSI protocol that defines how ESs (hosts) and ISs (routers) learn about each other. ES-IS configuration information is transmitted at regular intervals through the ES and IS hello messages. The hello messages contain the subnetwork and network layer addresses of the systems that generate them. The ES-IS configuration protocol communicates both OSI network layer addresses and OSI subnetwork addresses. OSI network layer addresses identify either the NSAP, which is the interface between OSI Layer 3 and Layer 4, or the NET, which is the network layer entity in an OSI IS. OSI SNPAs are the points at which an ES or IS is physically attached to a subnetwork. The SNPA address uniquely identifies each system attached to the subnetwork. In an Ethernet network, for example, the SNPA is the 48-bit MAC address. Part of the configuration information transmitted by ES-IS is the NSAP-to-SNPA or NET-to-SNPA mapping. 13.6.4.2 Intermediate System-to-Intermediate System Protocol IS-IS is an OSI link-state hierarchical routing protocol that floods the network with link-state information to build a complete, consistent picture of a network topology. IS-IS distinguishes between Level 1 and Level 2 ISs. Level 1 ISs communicate with other Level 1 ISs in the same area. Level 2 ISs route between Level 1 areas and form an intradomain routing backbone. Level 1 ISs need to know only how to get to the nearest Level 2 IS. The backbone routing protocol can change without impacting the intra-area routing protocol. OSI routing begins when the ESs discover the nearest IS by listening to ISH packets. When an ES wants to send a packet to another ES, it sends the packet to one of the ISs on its directly attached network. The router then looks up the destination address and forwards the packet along the best route. If the destination ES is on the same subnetwork, the local IS knows this from listening to ESHs and forwards the packet appropriately. The IS also might provide a redirect (RD) message back to the source to tell it that a more direct route is available. If the destination address is an ES on another subnetwork in the same area, the IS knows the correct route and forwards the packet appropriately. If the destination address is an ES in another area, the Level 1 IS sends the packet to the nearest Level 2 IS. Forwarding through Level 2 ISs continues until the packet reaches a Level 2 IS in the destination area. Within the destination area, the ISs forward the packet along the best path until the destination ES is reached. Link-state update messages help ISs learn about the network topology. Each IS generates an update specifying the ESs and ISs to which it is connected, as well as the associated metrics. The update is then sent to all neighboring ISs, which forward (flood) it to their neighbors, and so on. (Sequence numbers terminate the flood and distinguish old updates from new ones.) Using these updates, each IS can build a complete topology of the network. When the topology changes, new updates are sent. IS-IS uses a single required default metric with a maximum path value of 1024. The metric is arbitrary and typically is assigned by a network administrator. Any single link can have a maximum value of 64, and path links are calculated by summing link values. Maximum metric values were set at these levels to provide the granularity to support various link types while at the same time ensuring that the shortest-path algorithm used for route computation is reasonably efficient. Three optional IS-IS metrics (costs)—delay, expense, and error—are not supported by the ONS 15454. IS-IS maintains a mapping of the metrics to the quality of service (QoS) option in the CLNP packet header. IS-IS uses the mappings to compute routes through the internetwork. Cisco ONS 15454 Reference Manual, R8.5.x 13-36 78-18106-01 Chapter 13 Management Network Connectivity 13.6.5 TARP 13.6.5 TARP TARP is used when TL1 target identifiers (TIDs) must be translated to NSAP addresses. The TID-to-NSAP translation occurs by mapping TIDs to the NETs, then deriving NSAPs from the NETs by using the NSAP selector values (Table 13-8 on page 13-32). TARP uses a selective PDU propagation methodology in conjunction with a distributed database (that resides within the NEs) of TID-to-NET mappings. TARP allows NEs to translate between TID and NET by automatically exchanging mapping information with other NEs. The TARP PDU is carried by the standard CLNP Data PDU. TARP PDU fields are shown in Table 13-9. Table 13-9 TARP PDU Fields Field Abbreviation Size (bytes) Description TARP Lifetime tar-lif 2 The TARP time-to-live in hops. TARP Sequence tar-seq Number 2 The TARP sequence number used for loop detection. Protocol Address Type tar-pro 1 Used to identify the type of protocol address that the TID must be mapped to. The value FE is used to identify the CLNP address type. TARP Type Code tar-tcd 1 The TARP Type Code identifies the TARP type of PDU. Five TARP types, shown in Table 13-10, are defined. TID Target Length tar-tln 1 The number of octets that are in the tar-ttg field. TID Originator Length tar-oln 1 The number of octets that are in the tar-tor field. Protocol Address Length tar-pln 1 The number of octets that are in the tar-por field. TID of Target tar-ttg n = 0, 1, 2... TID value for the target NE. TID of Originator tar-tor n = 0, 1, 2... TID value of the TARP PDU originator. Protocol Address of Originator tar-por n = 0, 1, 2... Protocol address (for the protocol type identified in the tar-pro field) of the TARP PDU originator. When the tar-pro field is set to FE (hex), tar-por will contain a CLNP address (that is, the NET). Table 13-10 shows the TARP PDUs types that govern TARP interaction and routing. Table 13-10 TARP PDU Types Type Description Actions 1 Sent when a device has a TID for which After an NE originates a TARP Type 1 PDU, the PDU it has no matching NSAP. is sent to all adjacent NEs within the NE routing area. 2 Sent when a device has a TID for which After an NE originates a TARP Type 2 PDU, the PDU is sent to all Level 1 and Level 2 neighbors. it has no matching NSAP and no response was received from the Type 1 PDU. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-37 Chapter 13 Management Network Connectivity 13.6.5 TARP Table 13-10 TARP PDU Types (continued) Type Description Actions 3 Sent as a response to Type 1, Type 2, or After a TARP Request (Type 1 or 2) PDU is received, Type 5 PDUs. a TARP Type 3 PDU is sent to the request originator. Type 3 PDUs do not use the TARP propagation procedures. 4 Sent as a notification when a change occurs locally, for example, a TID or NSAP change. It might also be sent when an NE initializes. A Type 4 PDU is a notification of a TID or Protocol Address change at the NE that originates the notification. The PDU is sent to all adjacencies inside and outside the NE’s routing area. 5 Sent when a device needs a TID that corresponds to a specific NSAP. When a Type 5 PDU is sent, the CLNP destination address is known, so the PDU is sent to only that address. Type 5 PDUs do not use the TARP propagation procedures. 13.6.5.1 TARP Processing A TARP data cache (TDC) is created at each NE to facilitate TARP processing. In CTC, the TDC is displayed and managed on the node view Maintenance > OSI > TDC subtab. The TDC subtab contains the following TARP PDU fields: • TID—TID of the originating NE (tar-tor). • NSAP—NSAP of the originating NE. • Type— Indicates whether the TARP PDU was created through the TARP propagation process (dynamic) or manually created (static). Provisionable timers, shown in Table 13-11, control TARP processing. Table 13-11 TARP Timers Timer Description Default (seconds) Range (seconds) T1 Waiting for response to TARP Type 1 Request PDU 15 0–3600 T2 Waiting for response to TARP Type 2 Request PDU 25 0–3600 T3 Waiting for response to address resolution request 40 0–3600 T4 Timer starts when T2 expires (used during error recovery) 20 0–3600 Table 13-12 shows the main TARP processes and the general sequence of events that occurs in each process. Cisco ONS 15454 Reference Manual, R8.5.x 13-38 78-18106-01 Chapter 13 Management Network Connectivity 13.6.5 TARP Table 13-12 TARP Processing Flow Process Find a NET that matches a TID Find a TID that matches a NET General TARP Flow 1. TARP checks its TDC for a match. If a match is found, TARP returns the result to the requesting application. 2. If no match is found, a TARP Type 1 PDU is generated and Timer T1 is started. 3. If Timer T1 expires before a match if found, a Type 2 PDU is generated and Timer T2 is started. 4. If Timer T2 expires before a match is found, Timer T4 is started. 5. If Timer T4 expires before a match is found, a Type 2 PDU is generated and Timer T2 is started. A Type 5 PDU is generated. Timer T3 is used. However, if the timer expires, no error recovery procedure occurs, and a status message is provided to indicate that the TID cannot be found. Send a notification TARP generates a Type 4 PDU in which the tar-ttg field contains the NE TID of TID or protocol value that existed prior to the change of TID or protocol address. Confirmation address change that other NEs successfully received the address change is not sent. 13.6.5.2 TARP Loop Detection Buffer The TARP loop detection buffer (LDB) can be enabled to prevent duplicate TARP PDUs from entering the TDC. When a TARP Type 1, 2, or 4 PDU arrives, TARP checks its LDB for a NET address (tar-por) of the PDU originator match. If no match is found, TARP processes the PDU and assigns a tar-por, tar-seq (sequence) entry for the PDU to the LDB. If the tar-seq is zero, a timer associated with the LDB entry is started using the provisionable LDB entry timer on the node view OSI > TARP > Config tab. If a match exists, the tar-seq is compared to the LDB entry. If the tar-seq is not zero and is less than or equal to the LDB entry, the PDU is discarded. If the tar-seq is greater than the LDB entry, the PDU is processed and the tar-seq field in the LDB entry is updated with the new value. The Cisco ONS 15454 LDB holds approximately 500 entries. The LDB is flushed periodically based on the time set in the LDB Flush timer on the node view OSI > TARP > Config tab. 13.6.5.3 Manual TARP Adjacencies TARP adjacencies can be manually provisioned in networks where ONS 15454s must communicate across routers or non-SONET NEs that lack TARP capability. In CTC, manual TARP adjacencies are provisioned on the node view Provisioning > OSI > TARP > MAT (Manual Area Table) subtab. The manual adjacency causes a TARP request to hop through the general router or non-SONET NE, as shown in Figure 13-23. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-39 Chapter 13 Management Network Connectivity 13.6.6 TCP/IP and OSI Mediation Figure 13-23 Manual TARP Adjacencies DCN Generic router Manual adjacency 131957 DCN 13.6.5.4 Manual TID to NSAP Provisioning TIDs can be manually linked to NSAPs and added to the TDC. Static TDC entries are similar to static routes. For a specific TID, you force a specific NSAP. Resolution requests for that TID always return that NSAP. No TARP network propagation or instantaneous replies are involved. Static entries allow you to forward TL1 commands to NEs that do not support TARP. However, static TDC entries are not dynamically updated, so outdated entries are not removed after the TID or the NSAP changes on the target node. 13.6.6 TCP/IP and OSI Mediation Two mediation processes facilitate TL1 networking and file transfers between NEs and ONS client computers running TCP/IP and OSI protocol suites: • T–TD—Performs a TL1-over-IP to TL1-over-OSI gateway mediation to enable an IP-based OSS to manage OSI-only NEs subtended from a GNE. Figure 13-24 shows the T–TD protocol flow. Cisco ONS 15454 Reference Manual, R8.5.x 13-40 78-18106-01 Chapter 13 Management Network Connectivity 13.6.7 OSI Virtual Routers Figure 13-24 T–TD Protocol Flow OSS GNE ENE TL1 TL1 Gateway TL1 Gateway ACSE ACSE Presentation Presentation Session Session TP4 TP4 TL1 UDP • TCP UDP TCP TL1 IPv4 ISIS / CLNS ISIS / CLNS LLC1 LAPD LAPD LAN LAN DCC DCC 131954 IPv4 LLC1 FT–TD—Performs an FTP conversion between FTAM and FTP. The FT–TD gateway entity includes an FTAM responder (server) and an FTP client, allowing FTAM initiators (clients) to store, retrieve, or delete files from an FTP server. The FT–TD gateway is unidirectional and is driven by the FTAM initiator. The FT–TD FTAM responder exchanges messages with the FTAM initiator over the full OSI stack. Figure 13-25 shows the FT–TD protocol flow. Figure 13-25 FT–TD Protocol Flow OSS GNE ENE FT-TD FTP / IP FTAM / OSI FTP Client FTAM Responder FTAM Initiator 131955 FTP File Server The ONS 15454 uses FT–TD for the following file transfer processes: • Software downloads • Database backups and restores • Cisco IOS configuration backups and restores for ML and ML2 Series cards. 13.6.7 OSI Virtual Routers The ONS 15454 supports three OSI virtual routers. The routers are provisioned on the Provisioning > OSI > Routers tab, shown in Figure 13-26. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-41 Chapter 13 Management Network Connectivity 13.6.7 OSI Virtual Routers Figure 13-26 Provisioning OSI Routers Each router has an editable manual area address and a unique NSAP System ID that is set to the node MAC address + n. For Router 1, n = 0. For Router 2, n = 1. For Router 3, n = 2. Each router can be enabled and connected to different OSI routing areas. However, Router 1 is the primary router, and it must be enabled before Router 2 and Router 3 can be enabled. The Router 1 manual area address and System ID create the NSAP address assigned to the node’s TID. In addition, Router 1 supports OSI TARP, mediation, and tunneling functions that are not supported by Router 2 and Router 3. These include: • TID-to-NSAP resolution • TARP data cache • IP-over-CLNS tunnels • FTAM • FT-TD • T-TD • LAN subnet OSI virtual router constraints depend on the routing mode provisioned for the node. Table 13-13 shows the number of IS L1s, IS L1/L2s, and DCCs that are supported by each router. An IS Level1 and IS Level1/Level2 support one ES per DCC subnet and up to 100 ESs per LAN subnet. Cisco ONS 15454 Reference Manual, R8.5.x 13-42 78-18106-01 Chapter 13 Management Network Connectivity 13.6.8 IP-over-CLNS Tunnels Table 13-13 OSI Virtual Router Constraints Routing Mode IS L1 Router 1 Router 2 Router 3 per area IS L1/L2 per area DCC per IS End System Yes No No — — — IS L1 Yes Yes Yes 250 — 40 IS L1/L2 Yes Yes Yes 250 50 40 Each OSI virtual router has a primary manual area address. You can also create two additional manual area addresses. These manual area addresses can be used to: • Split up an area—Nodes within a given area can accumulate to a point that they are difficult to manage, cause excessive traffic, or threaten to exceed the usable address space for an area. Additional manual area addresses can be assigned so that you can smoothly partition a network into separate areas without disrupting service. • Merge areas—Use transitional area addresses to merge as many as three separate areas into a single area that shares a common area address. • Change to a different address—You might need to change an area address for a particular group of nodes. Use multiple manual area addresses to allow incoming traffic intended for an old area address to continue being routed to associated nodes. 13.6.8 IP-over-CLNS Tunnels IP-over-CLNS tunnels are used to encapsulate IP for transport across OSI NEs. The ONS 15454 supports two tunnel types: • GRE—Generic Routing Encapsulation is a tunneling protocol that encapsulates one network layer for transport across another. GRE tunnels add both a CLNS header and a GRE header to the tunnel frames. GRE tunnels are supported by Cisco routers and some other vendor NEs. • Cisco IP—The Cisco IP tunnel directly encapsulates the IP packet with no intermediate header. Cisco IP is supported by most Cisco routers. Figure 13-24 shows the protocol flow when an IP-over-CLNS tunnel is created through four NEs (A, B, C, and D). The tunnel ends are configured on NEs A and D, which support both IP and OSI. NEs B and C only support OSI, so they only route the OSI packets. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-43 Chapter 13 Management Network Connectivity 13.6.8 IP-over-CLNS Tunnels Figure 13-27 IP-over-CLNS Tunnel Flow NE-D NE-C NE-B NE-A (GNE) EMS HTTP FTP Telnet SNMP RMON HTTP FTP Telnet UDP TCP UDP TCP IPv4 GRE Tunnel CLNP CLNP CLNP CLNP LLC1 LAPD LAPD LAPD LAN DCC DCC DCC GRE Tunnel IPv4 IPv4 LAPD LLC1 LLC1 DCC LAN LAN 131956 SNMP RMON 13.6.8.1 Provisioning IP-over-CLNS Tunnels IP-over-CLNS tunnels must be carefully planned to prevent nodes from losing visibility or connectivity. Before you begin a tunnel, verify that the tunnel type, either Cisco IP or GRE, is supported by the equipment at the other end. Always verify IP and NSAP addresses. Provisioning of IP-over-CLNS tunnels in CTC is performed on the node view Provisioning > OSI > IP over CLNS Tunnels tab. For procedures, refer to the “Turn Up a Node” chapter in the Cisco ONS 15454 Procedure Guide. Provisioning IP-over-CLNS tunnels on Cisco routers requires the following prerequisite tasks, as well as other OSI provisioning: • (Required) Enable IS-IS • (Optional) Enable routing for an area on an interface • (Optional) Assign multiple area addresses • (Optional) Configure IS-IS interface parameters • (Optional) Configure miscellaneous IS-IS parameters The Cisco IOS commands used to create IP-over-CLNS tunnels (CTunnels) are shown in Table 13-14. Cisco ONS 15454 Reference Manual, R8.5.x 13-44 78-18106-01 Chapter 13 Management Network Connectivity 13.6.8 IP-over-CLNS Tunnels Table 13-14 IP-over-CLNS Tunnel IOS Commands Step Step Purpose 1 Router (config) # interface ctunnel interface-number Creates a virtual interface to transport IP over a CLNS tunnel and enters interface configuration mode. The interface number must be unique for each CTunnel interface. 2 Router (config-if # ctunnel destination remote-nsap-address Configures the destination parameter for the CTunnel. Specifies the destination NSAP1 address of the CTunnel, where the IP packets are extracted. 3 Router (config-if) # ip address ip-address mask Sets the primary or secondary IP address for an interface. If you are provisioning an IP-over-CLNS tunnel on a Cisco router, always follow procedures provided in the Cisco IOS documentation for the router you are provisioning. For information about ISO CLNS provisioning including IP-over-CLNS tunnels, see the “Configuring ISO CLNS” chapter in the Cisco IOS Apollo Domain, Banyon VINES, DECnet, ISO CLNS, and XNS Configuration Guide. 13.6.8.2 IP-over-CLNS Tunnel Scenario 1: ONS Node to Other Vendor GNE Figure 13-28 shows an IP-over-CLNS tunnel created from an ONS node to another vendor GNE. The other vendor NE has an IP connection to an IP DCN to which a CTC computer is attached. An OSI-only (LAP-D) SDCC and a GRE tunnel are created between the ONS NE 1 to the other vender GNE. ONS NE 1 IP-over-CLNS tunnel provisioning information: • Destination: 10.10.10.100 (CTC 1) • Mask: 255.255.255.255 for host route (CTC 1 only), or 255.255.255.0 for subnet route (all CTC computers residing on the 10.10.10.0 subnet) • NSAP: 39.840F.80.1111.0000.1111.1111.cccccccccccc.00 (other vendor GNE) • Metric: 110 • Tunnel Type: GRE Other vender GNE IP-over-CLNS tunnel provisioning information: • Destination: 10.20.30.30 (ONS NE 1) • Mask: 255.255.255.255 for host route (ONS NE 1 only), or 255.255.255.0 for subnet route (all ONS nodes residing on the 10.30.30.0 subnet) • NSAP: 39.840F.80.1111.0000.1111.1111.dddddddddddd.00 (ONS NE 1) • Metric: 110 • Tunnel Type: GRE Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-45 Chapter 13 Management Network Connectivity 13.6.8 IP-over-CLNS Tunnels Figure 13-28 IP-over-CLNS Tunnel Scenario 1: ONS NE to Other Vender GNE CTC 1 10.10.10.100/24 Router 2 Interface 0/0: 10.10.10.10/24 Interface 0/1: 10.10.20.10/24 39.840F.80.111111.0000.1111.1111.aaaaaaaaaaaa.00 IP DCN Router 1 Interface 0/0: 10.10.20.20/24 Interface 0/1: 10.10.30.10/24 39.840F.80. 111111.0000.1111.1111.bbbbbbbbbbbb.00 IP/OSI Vendor GNE 10.10.30.20/24 39.840F.80. 111111.0000.1111.1111.cccccccccccc.00 GRE tunnel OSI OSI-only DCC (LAPD) OSI ONS NE 1 10.10.30.30/24 39.840F.80. 111111.0000.1111.1111.dddddddddddd.00 134355 Other vendor NE 13.6.8.3 IP-over-CLNS Tunnel Scenario 2: ONS Node to Router Figure 13-29 shows an IP-over-CLNS tunnel from an ONS node to a router. The other vendor NE has an OSI connection to a router on an IP DCN, to which a CTC computer is attached. An OSI-only (LAP-D) SDCC is created between the ONS NE 1 and the other vender GNE. The OSI over IP tunnel can be either the Cisco IP tunnel or a GRE tunnel, depending on the tunnel types supported by the router. ONS NE 1 IP-over-CLNS tunnel provisioning: • Destination: 10.10.30.10 (Router 1, Interface 0/1) • Mask: 255.255.255.255 for host route (Router 1 only), or 255.255.255.0 for subnet route (all routers on the same subnet) • NSAP: 39.840F.80.1111.0000.1111.1111.bbbbbbbbbbbb.00 (Router 1) • Metric: 110 • Tunnel Type: Cisco IP Router 1 CTunnel (IP-over-CLNS) provisioning: ip routing Cisco ONS 15454 Reference Manual, R8.5.x 13-46 78-18106-01 Chapter 13 Management Network Connectivity 13.6.8 IP-over-CLNS Tunnels clns routing interface ctunnel 102 ip address 10.10.30.30 255.255.255.0 ctunnel destination 39.840F.80.1111.0000.1111.1111.dddddddddddd.00 interface Ethernet0/1 clns router isis router isis net 39.840F.80.1111.0000.1111.1111.bbbbbbbbbbbb.00 Figure 13-29 IP-over-CLNS Tunnel Scenario 2: ONS Node to Router CTC 1 10.10.10.100/24 Router 2 Interface 0/0: 10.10.10.10/24 Interface 0/1: 10.10.20.10/24 39.840F.80.111111.0000.1111.1111.aaaaaaaaaaaa.00 IP DCN Router 1 Interface 0/0: 10.10.20.20/24 Interface 0/1: 10.10.30.10/24 39.840F.80. 111111.0000.1111.1111.bbbbbbbbbbbb.00 OSI GRE or Cisco IP tunnel Other vendor GNE OSI OSI-only DCC (LAPD) OSI ONS NE 1 10.10.30.30/24 39.840F.80. 111111.0000.1111.1111.dddddddddddd.00 134356 Other vendor NE 13.6.8.4 IP-over-CLNS Tunnel Scenario 3: ONS Node to Router Across an OSI DCN Figure 13-30 shows an IP-over-CLNS tunnel from an ONS node to a router across an OSI DCN. The other vendor NE has an OSI connection to an IP DCN to which a CTC computer is attached. An OSI-only (LAP-D) SDCC is created between the ONS NE 1 and the other vender GNE. The OSI over IP tunnel can be either the Cisco IP tunnel or a GRE tunnel, depending on the tunnel types supported by the router. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-47 Chapter 13 Management Network Connectivity 13.6.8 IP-over-CLNS Tunnels ONS NE 1 IP-over-CLNS tunnel provisioning: • Destination: Router 2 IP address • Mask: 255.255.255.255 for host route (CTC 1 only), or 255.255.255.0 for subnet route (all CTC computers on the same subnet) • NSAP: Other vender GNE NSAP address • Metric: 110 • Tunnel Type: Cisco IP Router 2 IP-over-CLNS tunnel provisioning (sample Cisco IOS provisioning): ip routing clns routing interface ctunnel 102 ip address 10.10.30.30 255.255.255.0 ctunnel destination 39.840F.80.1111.0000.1111.1111.dddddddddddd.00 interface Ethernet0/1 clns router isis router isis net 39.840F.80.1111.0000.1111.1111.aaaaaaaaaaaa.00 Cisco ONS 15454 Reference Manual, R8.5.x 13-48 78-18106-01 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios Figure 13-30 IP-over-CLNS Tunnel Scenario 3: ONS Node to Router Across an OSI DCN CTC 1 10.10.10.100/24 IP Router 2 Interface 0/0: 10.10.10.10/24 Interface 0/1: 10.10.20.10/24 39.840F.80.111111.0000.1111.1111.aaaaaaaaaaaa.00 OSI DCN Router 1 Interface 0/0: 10.10.20.20/24 Interface 0/1: 10.10.30.10/24 39.840F.80. 111111.0000.1111.1111.bbbbbbbbbbbb.00 OSI Other vendor GNE GRE or Cisco IP tunnel OSI OSI-only DCC (LAPD) OSI ONS NE 1 10.10.30.30/24 39.840F.80. 111111.0000.1111.1111.dddddddddddd.00 134357 Other vendor NE 13.6.9 OSI/IP Networking Scenarios The following eight scenarios show examples of ONS 15454s in networks with OSI-based NEs. The scenarios show ONS 15454 nodes in a variety of roles. The scenarios assume the following: • ONS 15454 NEs are configured as dual OSI and IP nodes with both IP and NSAP addresses. They run both OSPF and OSI (IS-IS or ES-IS) routing protocols as “Ships-In-The-Night,” with no route redistribution. • ONS 15454 NEs run TARP, which allows them to resolve a TL1 TID to a NSAP address. A TID might resolve to both an IP and an NSAP address when the destination TID is an ONS 15454 NE that has both IP and NSAP address. • DCC links between ONS 15454 NEs and OSI-only NEs run the full OSI stack over LAP-D, which includes IS-IS, ES-IS, and TARP. • DCC links between ONS 15454 NEs run the full OSI stack and IP (OSPF) over PPP. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-49 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios • All ONS 15454 NEs participating in an OSI network run OSI over PPP between themselves. This is needed so that other vendor GNEs can route TL1 commands to all ONS 15454 NEs participating in the OSI network. 13.6.9.1 OSI/IP Scenario 1: IP OSS, IP DCN, ONS GNE, IP DCC, and ONS ENE Figure 13-31 shows OSI/IP Scenario 1, the current ONS 15454 IP-based implementation, with an IP DCN, IP-over-PPP DCC, and OSPF routing. Figure 13-31 OSI/IP Scenario 1: IP OSS, IP DCN, ONS GNE, IP DCC, and ONS ENE 1 CTC/CTM IP OSS IP IP IP DCN IP ONS GNE 2 IP/PPP/DCC IP/PPP/DCC ONS ENE ONS NE IP/OSPF 3 IP/PPP/DCC ONS NE ONS NE 1 IP OSS manages ONS 15454 using TL1 and FTP. 2 DCCs carry IP over the PPP protocol. 3 The ONS 15454 network is managed by IP over OSPF. 131930 IP/PPP/DCC 13.6.9.2 OSI/IP Scenario 2: IP OSS, IP DCN, ONS GNE, OSI DCC, and Other Vendor ENE OSI/IP Scenario 2 (Figure 13-32) shows an ONS 15454 GNE in a multivendor OSI network. Both the ONS 15454 GNE and the other vendor NEs are managed by an IP OSS using TL1 and FTP. The ONS 15454 is also managed by CTC and Cisco Transport Manager (CTM). Because the other vendor NE only supports TL1 and FTAM over the full OSI stack, the ONS 15454 GNE provides T–TD and FT–TD mediation to convert TL1/IP to TL1/OSI and FTAM/OSI to FTP/IP. Cisco ONS 15454 Reference Manual, R8.5.x 13-50 78-18106-01 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios Figure 13-32 OSI/IP Scenario 2: IP OSS, IP DCN, ONS GNE, OSI DCC, and Other Vendor ENE 1 CTC/CTM IP OSS IP IP IP DCN IP ONS GNE 2 3 4 IP and OSI/PPP/DCC OSI/LAP-D/DCC IP/OSPF ONS NE OSI/IS-IS Other vendor NE 5 ONS NE OSI/LAP-D/DCC Other vendor NE 131932 IP and OSI/PPP/DCC 1 The IP OSS manages ONS 15454 and other vendor NEs using TL1 and FTP. 2 The ONS 15454 GNE performs mediation for other vendor NEs. 3 DCCs between the ONS 15454 GNE and ONS 15454 NEs are provisioned for IP and OSI over PPP. 4 DCCs between the ONS 15454 GNE and other vendor NEs are provisioned for OSI over LAP-D. 5 The ONS 15454 and the other vendor NE network include IP over OSPF and OSI over the IS-IS protocol. The ONS 15454 GNE routes TL1 traffic to the correct NE by resolving the TL1 TID to either an IP or NSAP address. For TL1 traffic to other vendor NEs (OSI-only nodes), the TID is resolved to an NSAP address. The ONS 15454 GNE passes the TL1 to the mediation function, which encapsulates it over the full OSI stack and routes it to the destination using the IS-IS protocol. For TL1 traffic to ONS 15454 NEs, the TID is resolved to both an IP and an NSAP address. The ONS 15454 GNE follows the current TL1 processing model and forwards the request to the destination NE using the TCP/IP stack and OSPF routing. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-51 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios OSS-initiated software downloads consist of two parts: the OSS to destination NE TL1 download request and the file transfer. The TL1 request is handled the same as described in the previous paragraph. The ONS 15454 NEs use FTP for file transfers. OSI-only NEs use FTAM to perform file transfers. The FTAM protocol is carried over OSI between the OSI NE and the ONS 15454 GNE. The GNE mediation translates between FTAM to FTP. 13.6.9.3 OSI/IP Scenario 3: IP OSS, IP DCN, Other Vendor GNE, OSI DCC, and ONS ENE In OSI/IP Scenario 3 (Figure 13-33), all TL1 traffic between the OSS and GNE is exchanged over the IP DCN. TL1 traffic targeted for the GNE is processed locally. All other TL1 traffic is forwarded to the OSI stack, which performs IP-to-OSI TL1 translation. The TL1 is encapsulated in the full OSI stack and sent to the target NE over the DCC. The GNE can route to any node within the IS-IS domain because all NEs, ONS 15454 and non-ONS 15454, have NSAP addresses and support IS-IS routing. TL1 traffic received by an ONS 15454 NE and not addressed to its NSAP address is forwarded by IS-IS routing to the correct destination. TL1 traffic received by an ONS 15454 NE and addressed to its NSAP is sent up the OSI stack to the mediation function, which extracts the TL1 and passes it to the ONS 15454 TL1 processor. An OSS initiated software download includes the OSS-to-destination node TL1 download request and the file transfer. The TL1 request is handled as described in the previous paragraph. The target node uses FTAM for file transfers because the GNE does not support IP on the DCC and cannot forward FTP. The ONS 15454 NEs therefore must support an FTAM client and initiate file transfer using FTAM when subtended to an OSI GNE. In this scenario, the GNE has both IP and OSI DCN connections. The GNE only supports TL1 and FTP over IP. Both are translated and then carried over OSI to the destination ENE (ONS 15454 or OSI-only NE). All other IP traffic is discarded by the GNE. The CTC/CTM IP traffic is carried over an IP-over-OSI tunnel to an ONS 15454 NE. The tunnel is created between an external router and an ONS 15454 NE. The traffic is sent to the ONS 15454 terminating the tunnel. That ONS 15454 then forwards the traffic over the tunnel to CTC/CTM by way of the external router. Cisco ONS 15454 Reference Manual, R8.5.x 13-52 78-18106-01 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios Figure 13-33 OSI/IP Scenario 3: IP OSS, IP DCN, Other Vendor GNE, OSI DCC, and ONS ENE 1 CTC/CTM IP OSS IP IP IP DCN IP OSI 2 3 Other vendor GNE OSI/LAP-D/DCC OSI/LAPD/DCC IP and OSI/PPP/DCC ONS NE 2 4 Other vendor NE OSI/LAP-D/DCC Other vendor NE 131933 ONS NE 1 1 The IP OSS manages the ONS 15454 and other vendor NEs using TL1 and FTP. 2 The other vendor GNE performs mediation for TL1 and FTP, so the DCCs to the ONS 15454 and other vendor NEs are OSI-only. 3 CTC/CTM communicates with ONS 15454 NEs over a IP-over-CLNS tunnel. The tunnel is created from the ONS 15454 node to the external router. 4 The ONS 15454 NE exchanges TL1 over the full OSI stack using FTAM for file transfer. Figure 13-34 shows the same scenario, except the IP-over-CLNS tunnel endpoint is the GNE rather than the DCN router. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-53 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios Figure 13-34 OSI/IP Scenario 3 with OSI/IP-over-CLNS Tunnel Endpoint at the GNE 1 CTC/CTM IP OSS IP IP IP DCN 2 IP Other vendor GNE 4 3 OSI/LAP-D/DCC OSI/LAPD/DCC 5 IP and OSI/PPP/DCC ONS NE 2 Other vendor NE OSI/LAP-D/DCC Other vendor NE 131931 ONS NE 1 1 The IP OSS manages ONS and other vendor NEs using TL1 and FTP. 2 The router routes requests to the other vender GNE. 3 The other vendor GNE performs mediation for TL1 and FTP, so the DCCs to ONS 15454 and other vendor NEs are OSI-only. 4 CTC/CTM communicates with ONS 15454 NEs over an IP-over-CLNS tunnel between the ONS 15454 and the GNE. 5 ONS 15454 NEs exchange TL1 over the full OSI stack. FTAM is used for file transfer. 13.6.9.4 OSI/IP Scenario 4: Multiple ONS DCC Areas OSI/IP Scenario 4 (Figure 13-35) is similar to OSI/IP Scenario 3 except that the OSI GNE is subtended by multiple isolated ONS 15454 areas. A separate IP-over-CLNS tunnel is required to each isolated ONS 15454 OSPF area. An alternate approach is to create a single IP-over-CLNS tunnel from CTC/CTM to an ONS 15454 NE, and then to configure a tunnel from that NE to an NE in each isolated OSPF area. This approach requires additional static routes. Cisco ONS 15454 Reference Manual, R8.5.x 13-54 78-18106-01 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios Figure 13-35 OSI/IP Scenario 4: Multiple ONS DCC Areas 1 CTC/CTM IP OSS IP IP IP DCN IP IP 2 2 OSI 2 Other vendor GNE OSI/ LAP-D/ DCC OSI/ LAP-D/ DCC OSI/ LAP-D/ DCC ONS NE ONS NE IP and OSI/PPP/DCC IP and OSI/PPP/DCC IP and OSI/PPP/DCC ONS NE ONS NE ONS NE 131934 ONS NE 1 The IP OSS manages ONS 15454 and other vendor NEs using TL1 and FTP. 2 A separate tunnel is created for each isolated ONS 15454 DCC area. 13.6.9.5 OSI/IP Scenario 5: GNE Without an OSI DCC Connection OSI/IP Scenario 5 (Figure 13-36) is similar to OSI/IP Scenario 3 except that the OSI GNE only has an IP connection to the DCN. It does not have an OSI DCN connection to carry CTC/CTM IP traffic through an IP-over-OSI tunnel. A separate DCN to ONS 15454 NE connection is created to provide CTC/CTM access. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-55 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios Figure 13-36 OSI/IP Scenario 5: GNE Without an OSI DCC Connection 1 CTC/CTM IP OSS IP IP IP DCN IP IP 3 2 Other vendor GNE OSI/ LAP-D/ DCC ONS NE Other vendor NE IP and OSI/PPP/DCC OSI/LAP-D/DCC ONS NE Other vendor NE 131935 4 OSI/ LAP-D/ DCC 1 The IP OSS manages ONS 15454 and other vendor NEs using TL1 and FTP. 2 The other vendor GNE performs mediation on TL1 and FTP, so DCCs are OSI-only. 3 CTC/CTM communicates with ONS 15454 NEs over a separate IP DCN connection. 4 ONS 15454 NE exchanges TL1 over the full OSI stack. FTAM is used for file transfers. 13.6.9.6 OSI/IP Scenario 6: IP OSS, OSI DCN, ONS GNE, OSI DCC, and Other Vendor ENE OSI/IP Scenario 6 (Figure 13-37) shows how the ONS 15454 supports OSI DCNs. The OSI DCN has no impact on the ONS 15454 because all IP traffic (CTC/CTM, FTP, and TL1) is tunneled through the OSI DCN. Cisco ONS 15454 Reference Manual, R8.5.x 13-56 78-18106-01 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios Figure 13-37 OSI/IP Scenario 6: IP OSS, OSI DCN, ONS GNE, OSI DCC, and Other Vendor ENE 1 CTC/CTM IP OSS IP IP OSI OSI OSI DCN 3 2 OSI IP 4 ONS GNE ONS GNE IP and OSI/PPP/DCC ONS GNE OSI/ LAP-D/ DCC Other vendor NE OSI/LAP-D/DCC Other vendor NE 131936 OSI/ LAP-D/ DCC 1 The IP OSS manages ONS 15454 and other vendor NEs using TL1 and FTP. 2 OSS IP traffic is tunneled through the DCN to the ONS 15454 GNE. 3 CTC/CTM IP traffic is tunneled through the DCN to the ONS 15454 GNE. 4 The GNE performs mediation for other vendor NEs. 13.6.9.7 OSI/IP Scenario 7: OSI OSS, OSI DCN, Other Vender GNE, OSI DCC, and ONS NEs OSI/IP Scenario 7 (Figure 13-38) shows an example of a European network. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-57 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios Figure 13-38 OSI/IP Scenario 7: OSI OSS, OSI DCN, Other Vender GNE, OSI DCC, and ONS NEs 1 2 CTC/CTM IP OSS IP OSI OSI OSI DCN OSI 3 Other vendor GNE OSI/ LAP-D/ DCC ONS NE 1 Other vendor NE 1 IP and OSI/PPP/DCC ONS NE 2 OSI/ LAP-D/ DCC OSI/LAP-D/DCC Other vendor NE 2 IP and OSI/PPP/DCC 131937 ONS NE 3 1 ONS 15454 NEs are managed by CTC/CTM only (TL1/FTP is not used). 2 The OSI OSS manages other vendor NEs only. 3 CTC/CTM communicates with the ONS 15454 over a IP-over-CLNS tunnel between the ONS 15454 NE and external router. In European networks: • CTC and CTM are used for management only. • IP-over-CLNS tunnels are widely accepted and deployed. Cisco ONS 15454 Reference Manual, R8.5.x 13-58 78-18106-01 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios • TL1 management is not required. • FTP file transfer is not required. • TL1 and FTAM to FTP mediation is not required. Management traffic between CTC/CTM and ONS 15454 NEs is carried over an IP-over-CLNS tunnel. A static route is configured on the ONS 15454 that terminates the tunnel (ONS 15454 NE 1) so that downstream ONS 15454 NEs (ONS 15454 NE 2 and 3) know how to reach CTC/CTM. 13.6.9.8 OSI/IP Scenario 8: OSI OSS, OSI DCN, ONS GNE, OSI DCC, and Other Vender NEs OSI/IP Scenario 8 (Figure 13-39) is another example of a European network. Similar to OSI/IP Scenario 7, the ONS 15454 NEs are solely managed by CTC/CTM. The CTC/CTM IP traffic is carried over a IP-over-OSI tunnel between an external router and the ONS 15454 GNE. The GNE extracts the IP from the tunnel and forwards it to the destination ONS 15454. Management traffic between the OSS and other vendor NEs is routed by the ONS 15454 GNE and NEs. This is possible because all ONS 15454 NEs run dual stacks (OSI and IP). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-59 Chapter 13 Management Network Connectivity 13.6.9 OSI/IP Networking Scenarios Figure 13-39 OSI/IP Scenario 8: OSI OSS, OSI DCN, ONS GNE, OSI DCC, and Other Vender NEs 1 2 CTC/CTM IP OSS IP OSI OSI OSI DCN 3 OSI ONS GNE 4 IP and OSI/LAP-D/ DCC ONS NE 1 IP and OSI/PPP/DCC ONS NE 2 OSI/ LAP-D/ DCC Other vendor NE 1 OSI/LAP-D/DCC Other vendor NE 2 Other vendor NE 3 131938 OSI/PPP/DCC 1 The ONS NEs are managed by CTC/CTM only (TL1/FTP is not used). 2 The OSI OSS manages other vendor NEs only. 3 CTC/CTM communicates with the ONS 15454 over an IP-over-CLNS tunnel between the ONS 15454 NE and the external router. A static route is needed on the GNE. 4 The ONS 15454 GNE routes OSI traffic to other vendor NEs. No IP-over-CLNS tunnel is needed. Cisco ONS 15454 Reference Manual, R8.5.x 13-60 78-18106-01 Chapter 13 Management Network Connectivity 13.6.10 Provisioning OSI in CTC 13.6.10 Provisioning OSI in CTC Table 13-15 shows the OSI actions that are performed from the node view Provisioning tab. Refer to the Cisco ONS 15454 Procedure Guide for OSI procedures and tasks. Table 13-15 OSI Actions from the CTC Provisioning Tab Tab Actions OSI > Main Setup OSI > TARP > Config • View and edit Primary Area Address. • Change OSI routing mode. • Change LSP buffers. Configure the TARP parameters: • PDU L1/L2 propagation and origination. • TARP data cache and loop detection buffer. • LAN storm suppression. • Type 4 PDU on startup. • TARP timers: LDB, T1, T2, T3, T4. OSI > TARP > Static TDC Add and delete static TARP data cache entries. OSI > TARP > MAT Add and delete static manual area table entries. OSI > Routers > Setup • Enable and disable routers. • Add, delete, and edit manual area addresses. OSI > Routers > Subnets Edit SDCC, LDCC, and LAN subnets that are provisioned for OSI. OSI > Tunnels Add, delete, and edit Cisco and IP-over-CLNS tunnels. Comm Channels > SDCC Comm Channels > LDCC • Add OSI configuration to an SDCC. • Choose the data link layer protocol, PPP or LAP-D. • Add OSI configuration to an SDCC. Table 13-16 shows the OSI actions that are performed from the node view Maintenance tab. Table 13-16 OSI Actions from the CTC Maintenance Tab Tab Actions OSI > ISIS RIB View the IS-IS routing table. OSI > ESIS RIB View ESs that are attached to ISs. OSI > TDC • View the TARP data cache and identify static and dynamic entries. • Perform TID to NSAP resolutions. • Flush the TDC. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 13-61 Chapter 13 Management Network Connectivity 13.7 IPv6 Network Compatibility 13.7 IPv6 Network Compatibility Cisco ONS 15xxx products can function in an IPv6 network when an internet router that supports Network Address Translation - Protocol Translation (NAT-PT) is positioned between the GNE, such as an ONS 15454, and the client workstation. NAT-PT is defined in RFC-2766. IPv4 and IPv6 nodes communicate with each other using NAT-PT by allowing both IPv6 and IPv4 stacks to interface between the IPv6 DCN and the IPv4 DCC networks. NAT-PT binds addresses in IPv6 networks with addresses in IPv4 networks and vice versa to provide transparent routing for the packets traveling between address types. This requires no changes to end nodes and IP packet routing is completely transparent to end nodes. It does, however, require NAT-PT to track the sessions it supports and mandates that inbound and outbound datagrams pertaining to a session traverse the same NAT-PT router. Protocol translation is used to extend address translation with protocol syntax/semantics translation. Note Only Mozilla 1.7 is supported on clients interfacing with IPv6 networks. 13.8 FTP Support for ENE Database Backup The Cisco ONS 15454 provides FTP database backup and restore download to ENEs when proxy/firewall is enabled. This feature allows you to provision a list of legal FTP hosts in CTC, that can be used with TL1 commands to perform database backup/restore or software download. The FTP hosts can be provisioned to elapse after a specified time interval with the enable FTP relay function. Once FTP host are provisioned, and FTP Releay is enabled, TL1 users can then use the COPY-RFILE command to perform database backup/restore or software download to and from this list of legal FTP hosts that are provisioned to ENEs. Also, TL1 supports TID to IP address translation for the GNE TID that is specified in the FTP URL of COPY-RFILE and COPY-IOSCFG commands. Using the FTP Host provisioning feature in CTC and TL1 you can configure up to 12 valid FTP hosts. ENEs are allowed access through the firewall according to the time configured in the FTP Relay Timer in CTC or TL1. The time interval is 1 to 60 minutes, and once the timer elapses, all FTP access to the FTP host is blocked again. A time of 0 disallows ENE access to FTP commands through the firewall. When the firewall is not enabled (Proxy only), all FTP operations to the ENE will be allowed – software download, database backup/restore and IOS config file backup/restore. All FTP operations to the ENEs will be blocked when firewall is enabled. Cisco ONS 15454 Reference Manual, R8.5.x 13-62 78-18106-01 CH A P T E R 14 Alarm Monitoring and Management This chapter describes Cisco Transport Controller (CTC) alarm management. To troubleshoot specific alarms, refer to the Cisco ONS 15454 Troubleshooting Guide. Chapter topics include: • 14.1 Overview, page 14-1 • 14.2 LCD Alarm Counts, page 14-1 • 14.3 Alarm Information, page 14-2 • 14.4 Alarm Severities, page 14-9 • 14.5 Alarm Profiles, page 14-9 • 14.6 Alarm Suppression, page 14-13 • 14.7 External Alarms and Controls, page 14-14 14.1 Overview CTC detects and reports SONET alarms generated by the Cisco ONS 15454 and the larger SONET network. You can use CTC to monitor and manage alarms at the card, node, or network level. Alarming conforms to Telcordia GR-253 standard. Severities conform to Telcordia GR-474, but you can set alarm severities in customized alarm profiles or suppress CTC alarm reporting. For a detailed description of the standard Telcordia categories employed by Optical Networking System (ONS) nodes, refer to the Cisco ONS 15454 Troubleshooting Guide. Note ONS 15454 alarms can also be monitored and managed through Transaction Language One (TL1) or a network management system (NMS). 14.2 LCD Alarm Counts You can view node, slot, or port-level alarm counts and summaries using the buttons on the ONS 15454 LCD panel. The Slot and Port buttons toggle between display types; the Slot button toggles between node display and slot display, and the Port button toggles between slot and port views. Pressing the Status button after you choose the display mode changes the display from alarm count to alarm summary. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 14-1 Chapter 14 Alarm Monitoring and Management 14.3 Alarm Information The ONS 15454 has a one-button update for some commonly viewed alarm counts. If you press the Slot button once and then wait eight seconds, the display automatically changes from a slot alarm count to a slot alarm summary. If you press the Port button to toggle to port-level display, you can use the Port button to toggle to a specific slot and to view each port’s port-level alarm count. Figure 14-1 shows the LCD panel layout. Slot Shelf LCD Panel Status Port 8/18/03 24˚C 04.06-002L-10 FAN FAIL CRIT MAJ MIN 97758 Figure 14-1 14.3 Alarm Information You can use the Alarms tab to view card, node, or network-level alarms. The Alarms window shows alarms in conformance with Telcordia GR-253. This means that if a network problem causes two alarms, such as loss of frame (LOF) and loss of signal (LOS), CTC only shows the LOS alarm in this window because it supersedes LOF. (The LOF alarm can still be retrieved in the Conditions window.) The Path Width column in the Alarms and Conditions tabs expands upon alarmed object information contained in the access identifier (AID) string (such as “STS-4-1-3”) by giving the number of STSs contained in the alarmed path. For example, the Path Width will tell you whether a critical alarm applies to an STS1 or an STS48c. The column reports the width as a 1, 3, 6, 12, 48, etc. as appropriate, understood to be “STS-N.” Table 14-1 lists the column headings and the information recorded in each column. Table 14-1 Alarms Column Descriptions Column Information Recorded Num Num (number) is the quantity of alarm messages received, and is incremented automatically as alarms occur to display the current total of received error messages. (The column is hidden by default; to view it, right-click a column and choose Show Column > Num.) Ref Ref (reference) is a unique identification number assigned to each alarm to reference a specific alarm message that is displayed. (The column is hidden by default. To view it, right-click a column and choose Show Column.) New Indicates a new alarm. To change this status, click either the Synchronize button or the Delete Cleared Alarms button. Date Date and time of the alarm. Node Shows the name of the node where the condition or alarm occurred. (Visible in network view.) Object TL1 AID for the alarmed object. For an STSmon or VTmon, this is the monitored STS or VT object. Eqpt Type Card type in this slot. Cisco ONS 15454 Reference Manual, R8.5.x 14-2 78-18106-01 Chapter 14 Alarm Monitoring and Management 14.3 Alarm Information Table 14-1 Note Alarms Column Descriptions (continued) Column Information Recorded Shelf For dense wavelength division multiplexing (DWDM) configurations, the shelf where the alarmed object is located. Visible in network view. Slot Slot where the alarm occurred (appears only in network and node view). Port Port where the alarm is raised. For STSTerm and VTTerm, the port refers to the upstream card it is partnered with. Path Width Indicates how many STSs are contained in the alarmed path. This information complements the alarm object notation, which is explained in the “Alarm Troubleshooting” chapter of the Cisco ONS 15454 Troubleshooting Guide. Sev Severity level: CR (Critical), MJ (Major), MN (Minor), NA (Not Alarmed), NR (Not Reported). ST Status: R (raised), C (clear), or T (transient). SA When checked, indicates a service-affecting alarm. Cond The error message/alarm name. These names are alphabetically defined in the “Alarm Troubleshooting” chapter of the Cisco ONS 15454 Troubleshooting Guide. Description Description of the alarm. When an entity is put in the OOS,MT administrative state, the ONS 15454 suppresses all standing alarms on that entity. All alarms and events appear on the Conditions tab. You can change this behavior for the LPBKFACILITY and LPBKTERMINAL alarms. To display these alarms on the Alarms tab, set the NODE.general.ReportLoopbackConditionsOnPortsInOOS-MT to TRUE on the NE Defaults tab. Table 14-2 lists the color codes for alarm and condition severities. The inherited (I) and unset (U) severities are only listed in the network view Provisioning > Alarm Profiles tab. Table 14-2 Note Color Codes for Alarm and Condition Severities Color Description Red Raised Critical (CR) alarm Orange Raised Major (MJ) alarm Yellow Raised Minor (MN) alarm Magenta Raised Not Alarmed (NA) condition Blue Raised Not Reported (NR) condition White Cleared (C) alarm or condition Major and Minor alarms might appear yellow in CTC under certain circumstances. This is not due to a CTC problem but to a workstation memory and color utilization problem. For example, a workstation might run out of colors if many color-intensive applications are running. When using Netscape, you can limit the number of colors used by launching it from the command line with either the -install option or the -ncols 32 option. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 14-3 Chapter 14 Alarm Monitoring and Management 14.3.1 Viewing Alarms With Each Node’s Time Zone 14.3.1 Viewing Alarms With Each Node’s Time Zone By default, alarms and conditions are displayed with the time stamp of the CTC workstation where you are viewing them. But you can set the node to report alarms (and conditions) using the time zone where the node is located by clicking Edit > Preferences, and clicking the Display Events Using Each Node’s Timezone check box. 14.3.2 Controlling Alarm Display You can control the display of the alarms shown on the Alarms window. Table 14-3 shows the actions you can perform in the Alarms window. Table 14-3 Alarm Display Button/Check Box/Tool Action Filter button Allows you to change the display on the Alarms window to show only alarms that meet a certain severity level, occur in a specified time frame, and/or reflect specific conditions. For example, you can set the filter so that only critical alarms display on the window. If you enable the Filter feature by clicking the Filter button in one CTC view, such as node view, it is enabled in the others as well (card view and network view). Synchronize button Updates the alarm display. Although CTC displays alarms in real time, the Synchronize button allows you to verify the alarm display. This is particularly useful during provisioning or troubleshooting. Delete Cleared Alarms button Deletes, from the view, alarms that have been cleared. AutoDelete Cleared Alarms check box If checked, CTC automatically deletes cleared alarms. Filter tool Enables or disables alarm filtering in the card, node, or network view. When enabled or disabled, this state applies to other views for that node and for all other nodes in the network. For example, if the Filter tool is enabled in the node (default login) view Alarms window, the network view Alarms window and card view Alarms window also show the tool enabled. All other nodes in the network also show the tool enabled. 14.3.3 Filtering Alarms The alarm display can be filtered to prevent display of alarms with certain severities or alarms that occurred between certain dates and times. You can set the filtering parameters by clicking the Filter button at the bottom-left of the Alarms window. You can turn the filter on or off by clicking the Filter tool at the bottom-right of the window. CTC retains your filter activation setting. For example, if you turn the filter on and then log out, CTC keeps the filter active the next time you log in. Cisco ONS 15454 Reference Manual, R8.5.x 14-4 78-18106-01 Chapter 14 Alarm Monitoring and Management 14.3.4 Viewing Alarm-Affected Circuits 14.3.4 Viewing Alarm-Affected Circuits A user can view which ONS 15454 circuits are affected by a specific alarm by positioning the cursor over the alarm in the Alarm window and right-clicking. A shortcut menu appears (Figure 14-2). When the user selects the Select Affected Circuits option, the Circuits window opens to show the circuits that are affected by the alarm. Figure 14-2 Select Affected Circuits Option 14.3.5 Conditions Tab The Conditions window displays retrieved fault conditions. A condition is a fault or status detected by ONS 15454 hardware or software. When a condition occurs and continues for a minimum period, CTC raises a condition, which is a flag showing that this particular condition currently exists on the ONS 15454. The Conditions window shows all conditions that occur, including those that are superseded. For instance, if a network problem causes two alarms, such as LOF and LOS, CTC shows both the LOF and LOS conditions in this window (even though LOS supersedes LOF). Having all conditions visible can be helpful when troubleshooting the ONS 15454. If you want to retrieve conditions that obey a root-cause hierarchy (that is, LOS supersedes and replaces LOF), you can exclude the same root causes by checking “Exclude Same Root Cause” check box in the window. Fault conditions include reported alarms and Not Reported or Not Alarmed conditions. Refer to the trouble notifications information in the Cisco ONS 15454 Troubleshooting Guide for more information about alarm and condition classifications. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 14-5 Chapter 14 Alarm Monitoring and Management 14.3.6 Controlling the Conditions Display 14.3.6 Controlling the Conditions Display You can control the display of the conditions on the Conditions window. Table 14-4 shows the actions you can perform in the window. Table 14-4 Conditions Display Button Action Retrieve Retrieves the current set of all existing fault conditions, as maintained by the alarm manager, from the ONS 15454. Filter Allows you to change the Conditions window display to only show the conditions that meet a certain severity level or occur in a specified time. For example, you can set the filter so that only critical conditions display on the window. There is a Filter button on the lower-right of the window that allows you to enable or disable the filter feature. Exclude Same Root Cause Retrieves conditions that obey a root-cause hierarchy (for example, LOS supersedes and replaces LOF). 14.3.6.1 Retrieving and Displaying Conditions The current set of all existing conditions maintained by the alarm manager can be seen when you click the Retrieve button. The set of conditions retrieved is relative to the view. For example, if you click the button while displaying the node view, node-specific conditions are displayed. If you click the button while displaying the network view, all conditions for the network (including ONS 15454 nodes and other connected nodes) are displayed, and the card view shows only card-specific conditions. You can also set a node to display conditions using the time zone where the node is located, rather than the time zone of the PC where they are being viewed. See the “14.3.1 Viewing Alarms With Each Node’s Time Zone” section on page 14-4 for more information. 14.3.6.2 Conditions Column Descriptions Table 14-5 lists the Conditions window column headings and the information recorded in each column. Table 14-5 Conditions Column Description Column Information Recorded Date Date and time of the condition. Node Shows the name of the node where the condition or alarm occurred. (Visible in network view.) Object TL1 AID for the condition object. For an STSmon or VTmon, the object. Eqpt Type Card type in this slot. Shelf For DWDM configurations, the shelf where the alarmed object is located. Visible in network view. Slot Slot where the condition occurred (appears only in network and node view). Port Port where the condition occurred. For STSTerm and VTTerm, the port refers to the upstream card it is partnered with. Cisco ONS 15454 Reference Manual, R8.5.x 14-6 78-18106-01 Chapter 14 Alarm Monitoring and Management 14.3.7 Viewing History Table 14-5 Conditions Column Description (continued) Column Information Recorded Path Width Width of the data path. Sev 1 Severity level: CR (Critical), MJ (Major), MN (Minor), NA (Not Alarmed), NR (Not Reported). SA1 Indicates a service-affecting alarm (when checked). Cond The error message/alarm name; these names are alphabetically defined in the “Alarm Troubleshooting” chapter of the Cisco ONS 15454 Troubleshooting Guide. Description Description of the condition. 1. All alarms, their severities, and service-affecting statuses are also displayed in the Condition tab unless you choose to filter the alarm from the display using the Filter button. 14.3.6.3 Filtering Conditions The condition display can be filtered to prevent display of conditions (including alarms) with certain severities or that occurred between certain dates. You can set the filtering parameters by clicking the Filter button at the bottom-left of the Conditions window. You can turn the filter on or off by clicking the Filter tool at the bottom-right of the window. CTC retains your filter activation setting. For example, if you turn the filter on and then log out, CTC keeps the filter active the next time your user ID is activated. 14.3.7 Viewing History The History window displays historic alarm or condition data for the node or for your login session. You can choose to display only alarm history, only events, or both by checking check boxes in the History > Shelf window. You can view network-level alarm and condition history, such as for circuits, for all the nodes visible in network view. At the node level, you can see all port (facility), card, STS, and system-level history entries for that node. For example, protection-switching events or performance-monitoring threshold crossings appear here. If you double-click a card, you can view all port, card, and STS alarm or condition history that directly affects the card. Note In the Preference dialog General tab, the Maximum History Entries value only applies to the Session window. Different views of CTC display different kinds of history: Tip • The History > Session window is shown in network view, node view, and card view. It shows alarms and conditions that occurred during the current user CTC session. • The History > Shelf window is only shown in node view. It shows the alarms and conditions that occurred on the node since CTC software was operated on the node. • The History > Card window is only shown in card view. It shows the alarms and conditions that occurred on the card since CTC software was installed on the node. Double-click an alarm in the History window to display the corresponding view. For example, double-clicking a card alarm takes you to card view. In network view, double-clicking a node alarm takes you to node view. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 14-7 Chapter 14 Alarm Monitoring and Management 14.3.7 Viewing History If you check the History window Alarms check box, you display the node history of alarms. If you check the Events check box, you display the node history of Not Alarmed and transient events (conditions). If you check both check boxes, you retrieve node history for both. 14.3.7.1 History Column Descriptions Table 14-6 lists the History window column headings and the information recorded in each column. Table 14-6 History Column Description Column Information Recorded Num An incrementing count of alarm or condition messages. (The column is hidden by default; to view it, right-click a column and choose Show Column > Num.) Ref The reference number assigned to the alarm or condition. (The column is hidden by default; to view it, right-click a column and choose Show Column > Ref.) Date Date and time of the condition. Node Shows the name of the node where the condition or alarm occurred. (Visible in network view.) Object TL1 AID for the condition object. For an STSmon or VTmon, the object. Eqpt Type Card type in this slot. Shelf For DWDM configurations, the shelf where the alarmed object is located. Visible in network view. Slot Slot where the condition occurred (only displays in network view and node view). Port Port where the condition occurred. For STSTerm and VTTerm, the port refers to the upstream card it is partnered with. Path Width Width of the data path. Sev Severity level: Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR). ST Status: raised (R), cleared (C), or transient (T). SA Indicates a service-affecting alarm (when checked). Cond Condition name. Description Description of the condition. 14.3.7.2 Retrieving and Displaying Alarm and Condition History You can retrieve and view the history of alarms and conditions, as well as transients (passing notifications of processes as they occur) in the CTC history window. The information in this window is specific to the view where it is shown (that is, network history in the network view, node history in the node view, and card history in the card view). The node and card history views are each divided into two tabs. In node view, when you click the Retrieve button, you can see the history of alarms, conditions, and transients that have occurred on the node in the History > Shelf window, and the history of alarms, conditions, and transients that have occurred on the node during your login session in the History > Session window. In the card-view history window, after you retrieve the card history, you can see the history of alarms, conditions, and transients Cisco ONS 15454 Reference Manual, R8.5.x 14-8 78-18106-01 Chapter 14 Alarm Monitoring and Management 14.3.8 Alarm History and Log Buffer Capacities on the card in the History > Card window, or a history of alarms, conditions, and transients that have occurred during your login session in the History > Session window. You can also filter the severities and occurrence period in these history windows. 14.3.8 Alarm History and Log Buffer Capacities The ONS 15454 alarm history log, stored in the TCC2/TCC2P RSA memory, contains four categories of alarms. These include: • CR severity alarms • MJ severity alarms • MN severity alarms • the combined group of cleared, Not Alarmed severity, and Not Reported severity alarms Each category can store between 4 and 640 alarm chunks, or entries. In each category, when the upper limit is reached, the oldest entry in the category is deleted. The capacity is not user-provisionable. CTC also has a log buffer, separate from the alarm history log, that pertains to the total number of entries displayed in the Alarms, Conditions, and History windows. The total capacity is provisionable up to 5,000 entries. When the upper limit is reached, the oldest entries are deleted. 14.4 Alarm Severities ONS 15454 alarm severities follow the Telcordia GR-253 standard, so a condition might be Alarmed (at a severity of Critical [CR], Major [MJ], or Minor [MN]), Not Alarmed (NA), or Not Reported (NR). These severities are reported in the CTC software Alarms, Conditions, and History windows at all levels: network, shelf, and card. ONS equipment provides a standard profile named Default listing all alarms and conditions with severity settings based on Telcordia GR-474 and other standards, but users can create their own profiles with different settings for some or all conditions and apply these wherever desired. (See the “14.5 Alarm Profiles” section on page 14-9.) For example, in a custom alarm profile, the default severity of a carrier loss (CARLOSS) alarm on an Ethernet port could be changed from major to critical. The profile allows setting to Not Reported or Not Alarmed, as well as the three alarmed severities. Critical and Major severities are only used for service-affecting alarms. If a condition is set as Critical or Major by profile, it will raise as Minor alarm in the following situations: • In a protection group, if the alarm is on a standby entity (side not carrying traffic) • If the alarmed entity has no traffic provisioned on it, so no service is lost Because of this possibility of being raised at two different levels, the alarm profile pane shows Critical as CR / MN and Major as MJ / MN. 14.5 Alarm Profiles The alarm profiles feature allows you to change default alarm severities by creating unique alarm profiles for individual ONS 15454 ports, cards, or nodes. A created alarm profile can be applied to any node on the network. Alarm profiles can be saved to a file and imported elsewhere in the network, but the profile must be stored locally on a node before it can be applied to the node, its cards, or its cards’ ports. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 14-9 Chapter 14 Alarm Monitoring and Management 14.5.1 Creating and Modifying Alarm Profiles CTC can store up to ten active alarm profiles at any time to apply to the node. Custom profiles can take eight of these active profile positions. Two other profiles, Default profile and Inherited profile, are reserved by the NE, and cannot be edited.The reserved Default profile contains Telcordia GR-474 severities. The reserved Inherited profile allows port alarm severities to be governed by the card-level severities, or card alarm severities to be determined by the node-level severities. If one or more alarm profiles have been stored as files from elsewhere in the network onto the local PC or server hard drive where CTC resides, you can use as many profiles as you can physically store by deleting and replacing them locally in CTC so that only eight are active at any given time. 14.5.1 Creating and Modifying Alarm Profiles Alarm profiles are created in the network view using the Provisioning > Alarm Profiles tabs. Figure 14-3 shows the default list of alarm severities. A default alarm severity following Telcordia GR-253 standards is preprovisioned for every alarm. After loading the default profile or another profile on the node, you can clone a profile to create custom profiles. After the new profile is created, the Alarm Profiles window shows the original profile (frequently Default) and the new profile. Figure 14-3 Network View Alarm Profiles Window The alarm profile list contains a master list of alarms that is used for a mixed node network. Some of these alarms might not be used in all ONS nodes. Tip To see the full list of profiles including those available for loading or cloning, click the Available button. You must load a profile before you can clone it. Cisco ONS 15454 Reference Manual, R8.5.x 14-10 78-18106-01 Chapter 14 Alarm Monitoring and Management 14.5.2 Alarm Profile Buttons Note Up to 10 profiles, including the two reserved profiles (Inherited and Default) can be stored in CTC. Wherever it is applied, the Default alarm profile sets severities to standard Telcordia GR-253 settings. In the Inherited profile, alarms inherit, or copy, severity from the next-highest level. For example, a card with an Inherited alarm profile copies the severities used by the node housing the card. If you choose the Inherited profile from the network view, the severities at the lower levels (node and card) are copied from this selection. You do not have to apply a single severity profile to the node, card, and port alarms. Different profiles can be applied at different levels. You could use the inherited or default profile on a node and on all cards and ports, but apply a custom profile that downgrades an alarm on one particular card. For example, you might choose to downgrade an OC-N unequipped path alarm (UNEQ-P) from Critical (CR) to Not Alarmed (NA) on an optical card because this alarm raises and then clears every time you create a circuit. UNEQ-P alarms for the card with the custom profile would not display on the Alarms tab. (But they would still be recorded on the Conditions and History tabs.) When you modify severities in an alarm profile: • All Critical (CR) or Major (MJ) default or user-defined severity settings are demoted to Minor (MN) in Non-Service-Affecting (NSA) situations as defined in Telcordia GR-474. • Default severities are used for all alarms and conditions until you create a new profile and apply it. The Load and Store buttons are not available for Retrieve and Maintenance users. The Delete and Store options will only display nodes to delete profiles from or store profiles to if the user has provisioning permission for those nodes. If the user does not have the proper permissions, CTC greys out the buttons and they are not available to the user. 14.5.2 Alarm Profile Buttons The Alarm Profiles window displays six buttons at the bottom of the window. Table 14-7 lists and describes each of the alarm profile buttons and their functions. Table 14-7 Alarm Profile Buttons Button Description New Creates a new profile. Load Loads a profile to a node or a file. Store Saves profiles on a node (or nodes) or in a file. Delete Deletes profiles from a node. Compare Displays differences between alarm profiles (for example, individual alarms that are not configured equivalently between profiles). Available Displays all profiles available on each node. Usage Displays all entities (nodes and alarm subjects) present in the network and which profiles contain the alarm. Can be printed. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 14-11 Chapter 14 Alarm Monitoring and Management 14.5.3 Alarm Profile Editing 14.5.3 Alarm Profile Editing Table 14-8 lists and describes the five profile-editing options available when you right-click an alarm item in the profile column. Table 14-8 Alarm Profile Editing Options Button Description Store Saves a profile in a node or in a file. Rename Changes a profile name. Clone Creates a profile that contains the same alarm severity settings as the profile being cloned. Reset Restores a profile to its previous state or to the original state (if it has not yet been applied). Remove Removes a profile from the table editor. 14.5.4 Alarm Severity Options To change or assign alarm severity, left-click the alarm severity you want to change in the alarm profile column. Seven severity levels appear for the alarm: • Not Reported (NR) • Not Alarmed (NA) • Minor (MN) • Major (MJ) • Critical (CR) • Use Default • Inherited Inherited and Use Default severity levels only appear in alarm profiles. They do not appear when you view alarms, history, or conditions. 14.5.5 Row Display Options The Alarm Profiles window (from network view) or the Alarm Profile Editor (from node view) displays three check boxes at the bottom of the window: • Only show service-affecting severities—If unchecked, the editor shows severities in the format / where is a service-affecting severity and is not service-affecting. If checked, the editor only shows alarms. • Hide reference values—Highlights alarms with non-default severities by clearing alarm cells with default severities. This check-box is normally greyed out. It becomes active only when more than one profile is listed in the Alarm Profile Editor window. (The check box text changes to “Hide Values matching profile Default” in this case. • Hide identical rows—Hides rows of alarms that contain the same severity for each profile. Cisco ONS 15454 Reference Manual, R8.5.x 14-12 78-18106-01 Chapter 14 Alarm Monitoring and Management 14.5.6 Applying Alarm Profiles 14.5.6 Applying Alarm Profiles In CTC node view, the Alarm Behavior window displays alarm profiles for the node. In card view, the Alarm Behavior window displays the alarm profiles for the selected card. Alarm profiles form a hierarchy. A node-level alarm profile applies to all cards in the node except cards that have their own profiles. A card-level alarm profile applies to all ports on the card except ports that have their own profiles. At the node level, you can apply profile changes on a card-by-card basis or set a profile for the entire node. At the card-level view, you can apply profile changes on a port-by-port basis or set alarm profiles for all ports on that card. Figure 14-4 shows the DS1 card alarm profile. Figure 14-4 DS1 Card Alarm Profile 14.6 Alarm Suppression The following sections explain alarm suppression features for the ONS 15454. 14.6.1 Alarms Suppressed for Maintenance When you place a port in OOS,MT administrative state, this raises the alarm suppressed for maintenance (AS-MT) alarm in the Conditions and History windows1 and causes subsequently raised alarms for that port to be suppressed. 1. AS-MT can be seen in the Alarms window as well if you have set the Filter dialog box to show NA severity events. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 14-13 Chapter 14 Alarm Monitoring and Management 14.6.2 Alarms Suppressed by User Command While the facility is in the OOS,MT state, any alarms or conditions that are raised and suppressed on it (for example, a transmit failure [TRMT] alarm) are reported in the Conditions window and show their normal severity in the Sev column. The suppressed alarms are not shown in the Alarms and History windows. (These windows only show AS-MT). When you place the port back into IS,AINS administrative state, the AS-MT alarm is resolved in all three windows. Suppressed alarms remain raised in the Conditions window until they are cleared. 14.6.2 Alarms Suppressed by User Command In the Provisioning > Alarm Profiles > Alarm Behavior tabs, the ONS 15454 has an alarm suppression option that clears raised alarm messages for the node, chassis, one or more slots (cards), or one or more ports. Using this option raises the alarms suppressed by user command, or AS-CMD alarm. The AS-CMD alarm, like the AS-MT alarm, appears in the Conditions, and History1 windows. Suppressed conditions (including alarms) appear only in the Conditions window--showing their normal severity in the Sev column. When the Suppress Alarms check box is unchecked, the AS-CMD alarm is cleared from all three windows. A suppression command applied at a higher level does not supersede a command applied at a lower level. For example, applying a node-level alarm suppression command makes all raised alarms for the node appear to be cleared, but it does not cancel out card-level or port-level suppression. Each of these conditions can exist independently and must be cleared independently. Caution Use alarm suppression with caution. If multiple CTC or TL1 sessions are open, suppressing the alarms in one session suppresses the alarms in all other open sessions. 14.7 External Alarms and Controls External alarm inputs can be provisioned on the Alarm Interface Controller-International (AIC-I) card for external sensors such as an open door and flood sensors, temperature sensors, and other environmental conditions. External control outputs on these two cards allow you to drive external visual or audible devices such as bells and lights. They can control other devices such as generators, heaters, and fans. You provision external alarms in the AIC-I card view Provisioning > External Alarms tab and controls in the AIC-I card view Provisioning > External Controls tab. Up to 12 external alarm inputs and four external controls are available. If you also provision the alarm extension panel (AEP), there are 32 inputs and 16 outputs. 14.7.1 External Alarms You can provision each alarm input separately. Provisionable characteristics of external alarm inputs include: • Alarm Type—List of alarm types. • User Defined Alarm Types • Severity—CR, MJ, MN, NA, and NR. • Virtual Wire—The virtual wire associated with the alarm. Cisco ONS 15454 Reference Manual, R8.5.x 14-14 78-18106-01 Chapter 14 Alarm Monitoring and Management 14.7.2 User Defined Alarm Types • Raised When—Open means that the normal condition is to not have current flowing through the contact, and the alarm is generated when current does flow; closed means that the normal condition is to have current flowing through the contact, and the alarm is generated when current stops flowing. • Description—CTC alarm log description (up to 63 characters). Note If you provision an external alarm to raise when a contact is open, and you have not attached the alarm cable, the alarm will remain raised until the alarm cable is connected. Note When you provision an external alarm, the alarm object is ENV-IN-nn. The variable nn refers to the external alarm’s number, regardless of the name you assign. 14.7.2 User Defined Alarm Types User Defined Alarm Types allows you to dynamically add and delete the alarm types. In addition to the existing hard coded alarm type attributes, you can define up to 50 alarm types. These dynamically added alarm types can be associated, or disassociated, to any external alarm input and the added alarm type can use the same behavior as hard coded alarm type attributes. The following limits and guidelines apply: • An AIC or AIC-I card must be installed • Up to 50 Alarm Types can be defined • The User Defined name can be up to 20 alphanumeric characters (upper case). • The User Defined name can not contain special characters or spaces (Hyphen (-) is allowed) 14.7.3 External Controls You can provision each alarm output separately. Provisionable characteristics of alarm outputs include: • Control type. • Trigger type (alarm or virtual wire). • Description for CTC display. • Closure setting (manually or by trigger). If you provision the output closure to be triggered, the following characteristics can be used as triggers: – Local NE alarm severity—A chosen alarm severity (for example, major) and any higher-severity alarm (in this case, critical) causes output closure. – Remote NE alarm severity—Similar to local NE alarm severity trigger setting, but applies to remote alarms. – Virtual wire entities—You can provision an alarm that is input to a virtual wire to trigger an external control output. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 14-15 Chapter 14 Alarm Monitoring and Management 14.7.3 External Controls Cisco ONS 15454 Reference Manual, R8.5.x 14-16 78-18106-01 CH A P T E R 15 Performance Monitoring Performance monitoring (PM) parameters are used by service providers to gather, store, set thresholds for, and report performance data for early detection of problems. In this chapter, PM parameters and concepts are defined for electrical cards, ethernet cards, optical cards, optical multirate cards, and storage access networking (SAN) cards in the Cisco ONS 15454. For information about enabling and viewing PM values, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 15.1 Threshold Performance Monitoring, page 15-2 • 15.2 Intermediate Path Performance Monitoring, page 15-3 • 15.3 Pointer Justification Count Performance Monitoring, page 15-4 • 15.4 Performance Monitoring Parameter Definitions, page 15-5 • 15.5 Performance Monitoring for Electrical Cards, page 15-12 • 15.6 Performance Monitoring for Ethernet Cards, page 15-29 • 15.7 Performance Monitoring for Optical Cards, page 15-48 • 15.8 Performance Monitoring for Optical Multirate Cards, page 15-51 • 15.9 Performance Monitoring for Storage Access Networking Cards, page 15-52 Note For transponder (TXP), and muxponder (TXP), and DWDM card PM parameters, refer to the Cisco ONS 15454 DWDM Reference Manual. Note For additional information regarding PM parameters, refer to Telcordia documents GR-1230-CORE, GR-820-CORE, GR-499-CORE, and GR-253-CORE and the ANSI T1.231 document entitled Digital Hierarchy - Layer 1 In-Service Digital Transmission Performance Monitoring. Note When circuits transition from the out-of-service state to the in-service state, the performance monitoring counts during the out-of-service circuit state are not part of the accumulation cycle. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-1 Chapter 15 Performance Monitoring 15.1 Threshold Performance Monitoring 15.1 Threshold Performance Monitoring Thresholds are used to set error levels for each PM parameter. You can set individual PM threshold values from the Cisco Transport Controller (CTC) card view Provisioning tab. For procedures on provisioning card thresholds, such as line, path, and SONET thresholds, refer to the Cisco ONS 15454 Procedure Guide. During the accumulation cycle, if the current value of a PM parameter reaches or exceeds its corresponding threshold value, a threshold crossing alert (TCA) is generated by the node and displayed by CTC. TCAs provide early detection of performance degradation. When a threshold is crossed, the node continues to count the errors during a given accumulation period. If zero is entered as the threshold value, generation of TCAs is disabled, but performance monitoring continues. Change the threshold if the default value does not satisfy your error monitoring needs. For example, customers with a critical DS-1 installed for 911 calls must guarantee the best quality of service on the line; therefore, they lower all thresholds so that the slightest error raises a TCA. When TCAs occur, they appear in CTC. An example is T-UASP-P in the Cond column (shown in Figure 15-1), where the “T-” indicates a threshold crossing. For certain electrical cards, “RX” or “TX” is appended to the TCA description, as indicated by the red circles in Figure 15-1. The RX indicates that the TCA is associated with the receive direction, and TX indicates that the TCA is associated with the transmit direction. Figure 15-1 TCAs Displayed in CTC Table 15-1 shows the electrical cards for which RX and TX are appended to the TCA descriptions. Cisco ONS 15454 Reference Manual, R8.5.x 15-2 78-18106-01 Chapter 15 Performance Monitoring 15.2 Intermediate Path Performance Monitoring Table 15-1 Card Electrical Cards that Report RX and TX Direction for TCAs Line Path Near End Far End Near End Far End RX TX RX TX RX TX RX TX DS1-14 YES — YES — YES YES YES — DS1N-14 YES — YES — YES YES YES — Due to memory limitations and the number of TCAs generated by different platforms, you can manually add/modify the following two properties to the platform property file (CTC.INI for Windows and .ctcrc for UNIX): • ctc.15xxx.node.tr.lowater=yyy where xxx is the platform and yyy is the number of the lowater mark. The default lowater mark is 25. • ctc.15xxx.node.tr.hiwater=yyy where xxx is the platform and yyy is the number of the hiwater mark. The default hiwater mark is 50. If the number of the incoming TCA is greater than the hiwater mark, the node will keep the latest lowater mark and discard older ones. 15.2 Intermediate Path Performance Monitoring Intermediate path performance monitoring (IPPM) allows transparent monitoring of a constituent channel of an incoming transmission signal by a node that does not terminate that channel. Many large networks only use line terminating equipment (LTE), not path terminating equipment (PTE). Table 15-2 shows ONS 15454 cards that are considered LTE. Table 15-2 ONS 15454 Line Terminating Equipment ONS 15454 Electrical LTE EC1-12 card ONS 15454 Optical LTE OC3 IR 4/STM1 SH 1310 OC3 IR/STM1 SH 1310-8 OC12 IR/STM4 SH1310 OC12 LR/STM4 LH1310 OC12 LR/STM4 LH 1550 OC12 IR/STM4 SH 1310-4 OC48 IR/STM16 SH AS 1310 OC48 LR/STM16 LH AS 1550 OC48 ELR/STM16 EH 100 GHz OC48 ELR 200 GHz OC192 SR/STM64 IO 1310 OC192 IR/STM64 SH 1550 OC192 LR/STM64 LH 1550 OC192 LR/STM64 LH ITU 15xx.xx TXP_MR_10G MXP_2.5G_10G MXP_MR_2.5G MXPP_MR_2.5G MRC-12 MRC-2.5G-4 OC 192 - XFP Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-3 Chapter 15 Performance Monitoring 15.3 Pointer Justification Count Performance Monitoring ONS 15454 Software R3.0 and higher allows LTE cards to monitor near-end PM data on individual synchronous transport signal (STS) payloads by enabling IPPM. After enabling IPPM provisioning on the line card, service providers can monitor large amounts of STS traffic through intermediate nodes, thus making troubleshooting and maintenance activities more efficient. IPPM occurs only on STS paths that have IPPM enabled, and TCAs are raised only for PM parameters on the IPPM enabled paths. The monitored IPPM parameters are STS CV-P, STS ES-P, STS SES-P, STS UAS-P, and STS FC-P. Note Far-end IPPM is not supported by all OC-N cards. It is supported by OC3-4 and EC-1 cards. However, SONET path PMs can be monitored by logging into the far-end node directly. The ONS 15454 performs IPPM by examining the overhead in the monitored path and by reading all of the near-end path PM values in the incoming direction of transmission. The IPPM process allows the path signal to pass bidirectionally through the node completely unaltered. See Table 15-3 on page 15-5 for detailed information and definitions of specific IPPM parameters. 15.3 Pointer Justification Count Performance Monitoring Pointers are used to compensate for frequency and phase variations. Pointer justification counts indicate timing errors on SONET networks. When a network is out of synchronization, jitter and wander occur on the transported signal. Excessive wander can cause terminating equipment to slip. Slips cause different effects in service. Voice service has intermittent audible clicks. Compressed voice technology has short transmission errors or dropped calls. Fax machines lose scanned lines or experience dropped calls. Digital video transmission has distorted pictures or frozen frames. Encryption service loses the encryption key, causing data to be transmitted again. Pointers provide a way to align the phase variations in STS and VT payloads. The STS payload pointer is located in the H1 and H2 bytes of the line overhead. Clocking differences are measured by the offset in bytes from the pointer to the first byte of the STS synchronous payload envelope (SPE) called the J1 byte. Clocking differences that exceed the normal range of 0 to 782 can cause data loss. There are positive (PPJC) and negative (NPJC) pointer justification count parameters. PPJC is a count of path-detected (PPJC-PDET-P) or path-generated (PPJC-PGEN-P) positive pointer justifications. NPJC is a count of path-detected (NPJC-PDET-P) or path-generated (NPJC-PGEN-P) negative pointer justifications depending on the specific PM name. PJCDIFF is the absolute value of the difference between the total number of detected pointer justification counts and the total number of generated pointer justification counts. PJCS-PDET-P is a count of the one-second intervals containing one or more PPJC-PDET or NPJC-PDET. PJCS-PGEN-P is a count of the one-second intervals containing one or more PPJC-PGEN or NPJC-PGEN. A consistent pointer justification count indicates clock synchronization problems between nodes. A difference between the counts means that the node transmitting the original pointer justification has timing variations with the node detecting and transmitting this count. Positive pointer adjustments occur when the frame rate of the SPE is too slow in relation to the rate of the STS-1. You must enable PPJC and NPJC performance monitoring parameters for LTE cards. See Table 15-2 on page 15-3 for a list of Cisco ONS 15454 LTE cards. In CTC, the count fields for PPJC and NPJC PMs appear white and blank unless they are enabled on the card view Provisioning tab. See Table 15-3 on page 15-5 for detailed information and definitions of specific pointer justification count PM parameters. Cisco ONS 15454 Reference Manual, R8.5.x 15-4 78-18106-01 Chapter 15 Performance Monitoring 15.4 Performance Monitoring Parameter Definitions 15.4 Performance Monitoring Parameter Definitions Table 15-3 gives definitions for each type of PM parameter found in this chapter. Table 15-3 Performance Monitoring Parameters Parameter Definition AISS-P AIS Seconds Path (AISS-P) is a count of one-second intervals containing one or more alarm indication signal (AIS) defects. BBE-PM Path Monitoring Background Block Errors (BBE-PM) indicates the number of background block errors recorded in the optical transport network (OTN) path during the PM time interval. BBE-SM Section Monitoring Background Block Errors (BBE-SM) indicates the number of background block errors recorded in the OTN section during the PM time interval. BBER-PM Path Monitoring Background Block Errors Ratio (BBER-PM) indicates the background block errors ratio recorded in the OTN path during the PM time interval. BBER-SM Section Monitoring Background Block Errors Ratio (BBER-SM) indicates the background block errors ratio recorded in the OTN section during the PM time interval. BIT-EC Bit Errors Corrected (BIT-EC) indicated the number of bit errors corrected in the DWDM trunk line during the PM time interval. CSS Controlled Slip Seconds (CSS) indicates the count of the seconds when at least one or more controlled slips have occurred. CSS-P Controlled Slip Seconds Path (CSS-P) indicates the count of the seconds when at least one or more controlled slips have occurred. CVCP-P Code Violation CP-bit Path (CVCP-P) is a count of CP-bit parity errors occurring in the accumulation period. CVCP-PFE Code Violation CP-bit Path (CVCP-PFE) is a parameter that is counted when the three far-end block error (FEBE) bits in an M-frame are not all collectively set to 1. CGV Code Group Violations (CGV) is a count of received code groups that do not contain a start or end delimiter. CV-L Line Code Violation (CV-L) indicates the number of coding violations occurring on the line. This parameter is a count of bipolar violations (BPVs) and excessive zeros (EXZs) occurring over the accumulation period. CV-P Near-End STS Path Coding Violations (CV-P) is a count of BIP errors detected at the STS path layer (that is, using the B3 byte). Up to eight BIP errors can be detected per frame; each error increments the current CV-P second register. CV-PFE Far-End STS Path Coding Violations (CV-PFE) is a count of BIP errors detected at the STS path layer (that is, using the B3 byte). Up to eight BIP errors can be detected per frame; each error increments the current CV-PFE second register. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-5 Chapter 15 Performance Monitoring 15.4 Performance Monitoring Parameter Definitions Table 15-3 Performance Monitoring Parameters (continued) Parameter Definition CVP-P Code Violation Path (CVP-P) is a code violation parameter for M23 applications. CVP-P is a count of P-bit parity errors occurring in the accumulation period. CV-S Section Coding Violation (CV-S) is a count of bit interleaved parity (BIP) errors detected at the section layer (that is, using the B1 byte in the incoming SONET signal). Up to eight section BIP errors can be detected per STS-N frame; each error increments the current CV-S second register. CV-V Code Violation VT Layer (CV-V) is a count of the BIP errors detected at the VT path layer. Up to two BIP errors can be detected per VT superframe, with each error incrementing the current CV-V second register. DCG Data Code Groups (DCG) is a count of received data code groups that do not contain ordered sets. ESA-P Path Errored Seconds-A (ESA-P) is the count of 1-second intervals with exactly one CRC-6 error and no AIS or severely errored framing (SEF) defects. ESB-P Path Errored Seconds-B (Rx ESB-P) is a count of 1-second intervals with between 2 and 319 CRC-6 errors and no AIS or SEF. ESCP-P Errored Seconds CP-bit Path (ESCP-P) is a count of seconds containing one or more CP-bit parity errors, one or more SEF defects, or one or more AIS defects. ESCP-P is defined for the C-bit parity application. ESCP-PFE Far-End Errored Seconds CP-bit Path (ESCP-PFE) is a count of one-second intervals containing one or more M-frames with the three FEBE bits not all collectively set to 1 or one or more far-end SEF/AIS defects. ES-L Line Errored Seconds (ES-L) is a count of the seconds containing one or more anomalies (BPV + EXZ) and/or defects (that is, loss of signal) on the line. ES-NP ES-P Near-End STS Path Errored Seconds (ES-P) is a count of the seconds when at least one STS path BIP error was detected. An AIS Path (AIS-P) defect (or a lower-layer, traffic-related, near-end defect) or a Loss of Pointer Path (LOP-P) defect can also cause an ES-P. ES-PFE Far-End STS Path Errored Seconds (ES-PFE) is a count of the seconds when at least one STS path BIP error was detected. An AIS-P defect (or a lower-layer, traffic-related, far-end defect) or an LOP-P defect can also cause an STS ES-PFE. ES-PM Path Monitoring Errored Seconds (ES-PM) indicates the errored seconds recorded in the OTN path during the PM time interval. ESP-P Errored Seconds Path (ESP-P) is a count of seconds containing one or more P-bit parity errors, one or more SEF defects, or one or more AIS defects. ESR-PM Path Monitoring Errored Seconds Ratio (ESR-PM) indicates the errored seconds ratio recorded in the OTN path during the PM time interval. Cisco ONS 15454 Reference Manual, R8.5.x 15-6 78-18106-01 Chapter 15 Performance Monitoring 15.4 Performance Monitoring Parameter Definitions Table 15-3 Performance Monitoring Parameters (continued) Parameter Definition ESR-SM Section Monitoring Errored Seconds Ratio (ESR-SM) indicates the errored seconds ratio recorded in the OTN section during the PM time interval. ES-S Section Errored Seconds (ES-S) is a count of the number of seconds when at least one section-layer BIP error was detected or an SEF or loss of signal (LOS) defect was present. ES-SM Section Monitoring Errored Seconds (ES-SM) indicates the errored seconds recorded in the OTN section during the PM time interval. ES-V Errored Seconds VT Layer (ES-V) is a count of the seconds when at least one VT Path BIP error was detected. An AIS Virtual Tributary (VT) (AIS-V) defect (or a lower-layer, traffic-related, near-end defect) or an LOP VT (LOP-V) defect can also cause an ES-V. FC-L Line Failure Count (FC-L) is a count of the number of near-end line failure events. A failure event begins when an AIS Line (AIS-L) failure is declared or when a lower-layer, traffic-related, near-end failure is declared. This failure event ends when the failure is cleared. A failure event that begins in one period and ends in another period is counted only in the period where it begins. FC-P Near-End STS Path Failure Counts (FC-P) is a count of the number of near-end STS path failure events. A failure event begins when an AIS-P failure, an LOP-P failure, a UNEQ-P failure, or a Section Trace Identifier Mismatch Path (TIM-P) failure is declared. A failure event also begins if the STS PTE that is monitoring the path supports Three-Bit (Enhanced) Remote Failure Indication Path Connectivity (ERFI-P-CONN) for that path. The failure event ends when these failures are cleared. FC-PFE Far-End STS Path Failure Counts (FC-PFE) is a count of the number of near-end STS path failure events. A failure event begins when an AIS-P failure, an LOP-P failure, a UNEQ-P failure, or a TIM-P failure is declared. A failure event also begins if the STS PTE that is monitoring the path supports ERFI-P-CONN for that path. The failure event ends when these failures are cleared. FC-PM Path Monitoring Failure Counts (FC-PM) indicates the failure counts recorded in the OTN path during the PM time interval. FC-SM Section Monitoring Failure Counts (FC-SM) indicates the failure counts recorded in the OTN section during the PM time interval. IOS Idle Ordered Sets (IOS) is a count of received packets containing idle ordered sets. IPC Invalid Packets (IPC) is the count of received packets that contain errored data code groups that have start and end delimiters. LBCL-MIN Laser Bias Current Line—Minimum (LBCL-MIN) is the minimum percentage of laser bias current. LBCL-AVG Laser Bias Current Line—Average (LBCL-AVG) is the average percentage of laser bias current. LBCL-MAX Laser Bias Current Line—Maximum (LBCL-MAX) is the maximum percentage of laser bias current. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-7 Chapter 15 Performance Monitoring 15.4 Performance Monitoring Parameter Definitions Table 15-3 Performance Monitoring Parameters (continued) Parameter Definition LOFC Loss of Frame Count (LOFC) LOSS-L Line Loss of Signal (LOSS-L) is a count of one-second intervals containing one or more LOS defects. NIOS Non-Idle Ordered Sets (NIOS) is a count of received packets containing non-idle ordered sets. NPJC-PDET Negative Pointer Justification Count, STS Detected (NPJC-PDET), formerly Pointer Justification Negative (PJNEG) NPJC-PDET-P Negative Pointer Justification Count, STS Path Detected (NPJC-PDET-P) is a count of the negative pointer justifications detected on a particular path in an incoming SONET signal. NPJC-PGEN-P Negative Pointer Justification Count, STS Path Generated (NPJC-PGEN-P) is a count of the negative pointer justifications generated for a particular path to reconcile the frequency of the SPE with the local clock. OPR Optical Power Received (OPR) is the measure of average optical power received as a percentage of the nominal OPR. OPR-AVG Average Receive Optical Power (dBm) OPR-MAX Maximum Receive Optical Power (dBm) OPR-MIN Minimum Receive Optical Power (dBm) OPT Optical Power Transmitted (OPT) is the measure of average optical power transmitted as a percentage of the nominal OPT. OPT-AVG Average Transmit Optical Power (dBm) OPT-MAX Maximum Transmit Optical Power (dBm) OPT-MIN Minimum Transmit Optical Power (dBm) OPWR-AVG Optical Power - Average (OPWR-AVG) is the measure of average optical power on the unidirectional port. OPWR-MAX Optical Power - Maximum (OPWR-MAX) is the measure of maximum value of optical power on the unidirectional port. OPWR-MIN Optical Power - Minimum (OPWR-MIN) is the measure of minimum value of optical power on the unidirectional port. PJCDIFF-P Pointer Justification Count Difference, STS Path (PJCDIFF-P) is the absolute value of the difference between the total number of detected pointer justification counts and the total number of generated pointer justification counts. That is, PJCDiff-P is equal to (PPJC-PGEN-P – NPJC-PGEN-P) – (PPJC-PDET-P – NPJC-PDET-P). PPJC-PDET Pointer Justification STS Detected (PPJC-PDET), formerly Pointer Justification Positive (PJPOS). PPJC-PDET-P Positive Pointer Justification Count, STS Path Detected (PPJC-PDET-P) is a count of the positive pointer justifications detected on a particular path in an incoming SONET signal. Cisco ONS 15454 Reference Manual, R8.5.x 15-8 78-18106-01 Chapter 15 Performance Monitoring 15.4 Performance Monitoring Parameter Definitions Table 15-3 Performance Monitoring Parameters (continued) Parameter Definition PPJC-PGEN-P Positive Pointer Justification Count, STS Path Generated (PPJC-PGEN-P) is a count of the positive pointer justifications generated for a particular path to reconcile the frequency of the SPE with the local clock. PJCS-PDET-P Pointer Justification Count Seconds, STS Path Detect (NPJCS-PDET-P) is a count of the one-second intervals containing one or more PPJC-PDET or NPJC-PDET. PJCS-PGEN-P Pointer Justification Count Seconds, STS Path Generate (PJCS-PGEN-P) is a count of the one-second intervals containing one or more PPJC-PGEN or NPJC-PGEN. PSC In a 1 + 1 protection scheme for a working card, Protection Switching Count (PSC) is a count of the number of times service switches from a working card to a protection card plus the number of times service switches back to the working card. For a protection card, PSC is a count of the number of times service switches to a working card from a protection card plus the number of times service switches back to the protection card. The PSC PM parameter is only applicable if revertive line-level protection switching is used. PSC-R In a four-fiber bidirectional line switched ring (BLSR), Protection Switching Count-Ring (PSC-R) is a count of the number of times service switches from a working line to a protection line plus the number of times it switches back to a working line. A count is only incremented if ring switching is used. PSC-S In a four-fiber BLSR, Protection Switching Count-Span (PSC-S) is a count of the number of times service switches from a working line to a protection line plus the number of times it switches back to the working line. A count is only incremented if span switching is used. PSC-W For a working line in a two-fiber BLSR, Protection Switching Count-Working (PSC-W) is a count of the number of times traffic switches away from the working capacity in the failed line and back to the working capacity after the failure is cleared. PSC-W increments on the failed working line and PSC increments on the active protect line. For a working line in a four-fiber BLSR, PSC-W is a count of the number of times service switches from a working line to a protection line plus the number of times it switches back to the working line. PSC-W increments on the failed line and PSC-R or PSC-S increments on the active protect line. PSD Protection Switching Duration (PSD) applies to the length of time, in seconds, that service is carried on another line. For a working line, PSD is a count of the number of seconds that service was carried on the protection line. For the protection line, PSD is a count of the seconds that the line was used to carry service. The PSD PM is only applicable if revertive line-level protection switching is used. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-9 Chapter 15 Performance Monitoring 15.4 Performance Monitoring Parameter Definitions Table 15-3 Performance Monitoring Parameters (continued) Parameter Definition PSD-R In a four-fiber BLSR, Protection Switching Duration-Ring (PSD-R) is a count of the seconds that the protection line was used to carry service. A count is only incremented if ring switching is used. PSD-S In a four-fiber BLSR, Protection Switching Duration-Span (PSD-S) is a count of the seconds that the protection line was used to carry service. A count is only incremented if span switching is used. SASCP-P SEF/AIS Seconds CP-bit Path (SASCP-P) is a count of one-second intervals containing one or more SEFs or one or more AIS defects on the path. SASP SEF/AIS Seconds (SASP) is a count of one-second intervals containing one or more SEFs or one or more AIS defects on the path. SASP-P SEF/AIS Seconds Path (SASP-P) is a count of one-second intervals containing one or more SEFs or one or more AIS defects on the path. SEF-S Severely Errored Framing Seconds (SEFS-S) is a count of the seconds when an SEF defect was present. An SEF defect is expected to be present during most seconds when an LOS or loss of frame (LOF) defect is present. However, there can be situations when the SEFS-S parameter is only incremented based on the presence of the SEF defect. SESCP-P Severely Errored Seconds CP-bit Path (SESCP-P) is a count of seconds containing more than 44 CP-bit parity errors, one or more SEF defects, or one or more AIS defects. SESCP-PFE Severely Errored Seconds CP-bit Path (SESCP-PFE) is a count of one-second intervals containing one or more far-end SEF/AIS defects, or one or more 44 M-frames with the three FEBE bits not all collectively set to 1. SES-L Line Severely Errored Seconds (SES-L) is a count of the seconds containing more than a particular quantity of anomalies (BPV + EXZ > 44) and/or defects on the line. SES-P Near-End STS Path Severely Errored Seconds (SES-P) is a count of the seconds when K (2400) or more STS path BIP errors were detected. An AIS-P defect (or a lower-layer, traffic-related, near-end defect) or an LOP-P defect can also cause an SES-P. SES-PFE Far-End STS Path Severely Errored Seconds (SES-PFE) is a count of the seconds when K (2400) or more STS path BIP errors were detected. An AIS-P defect (or a lower-layer, traffic-related, far-end defect) or an LOP-P defect can also cause an SES-PFE. SES-PM Path Monitoring Severely Errored Seconds (SES-PM) indicates the severely errored seconds recorded in the OTN path during the PM time interval. SESP-P Severely Errored Seconds Path (SESP-P) is a count of seconds containing more than 44 P-bit parity violations, one or more SEF defects, or one or more AIS defects. SES-S Section Severely Errored Seconds (SES-S) is a count of the seconds when K (see Telcordia GR-253 for value) or more section-layer BIP errors were detected or an SEF or LOS defect was present. Cisco ONS 15454 Reference Manual, R8.5.x 15-10 78-18106-01 Chapter 15 Performance Monitoring 15.4 Performance Monitoring Parameter Definitions Table 15-3 Performance Monitoring Parameters (continued) Parameter Definition SES-SM Section Monitoring Severely Errored Seconds (SES-SM) indicates the severely errored seconds recorded in the OTN section during the PM time interval. SESR-PM Path Monitoring Severely Errored Seconds Ratio (SESR-PM) indicates the severely errored seconds ratio recorded in the OTN path during the PM time interval. SESR-SM Section Monitoring Severely Errored Seconds Ratio (SESR-SM) indicates the severely errored seconds ratio recorded in the OTN section during the PM time interval. SES-V Severely Errored Seconds VT Layer (SES-V) is a count of seconds when K (600) or more VT Path BIP errors were detected. An AIS-V defect (or a lower-layer, traffic-related, near-end defect) or an LOP-V defect can also cause SES-V. UAS-L Line Unavailable Seconds (UAS-L) is a count of the seconds when the line is unavailable. A line becomes unavailable when ten consecutive seconds occur that qualify as SES-Ls, and it continues to be unavailable until ten consecutive seconds occur that do not qualify as SES-Ls. UASCP-P Unavailable Seconds CP-bit Path (UASCP-P) is a count of one-second intervals when the DS-3 path is unavailable. A DS-3 path becomes unavailable when ten consecutive SESCP-Ps occur. The ten SESCP-Ps are included in unavailable time. After the DS-3 path becomes unavailable, it becomes available again when ten consecutive seconds with no SESCP-Ps occur. The ten seconds with no SESCP-Ps are excluded from unavailable time. UASCP-PFE Unavailable Seconds CP-bit Path (UASCP-PFE) is a count of one-second intervals when the DS-3 path becomes unavailable. A DS-3 path becomes unavailable when ten consecutive far-end CP-bit SESs occur. The ten CP-bit SESs are included in unavailable time. After the DS-3 path becomes unavailable, it becomes available again when ten consecutive seconds occur with no CP-bit SESs. The ten seconds with no CP-bit SESs are excluded from unavailable time. UAS-P Near-End STS Path Unavailable Seconds (UAS-P) is a count of the seconds when the STS path was unavailable. An STS path becomes unavailable when ten consecutive seconds occur that qualify as SES-Ps, and continues to be unavailable until ten consecutive seconds occur that do not qualify as SES-Ps. UAS-PFE Far-End STS Path Unavailable Seconds (UAS-PFE) is a count of the seconds when the STS path was unavailable. An STS path becomes unavailable when ten consecutive seconds occur that qualify as SES-PFEs, and continues to be unavailable until ten consecutive seconds occur that do not qualify as SES-PFEs. UAS-PM Path Monitoring Unavailable Seconds (UAS-PM) indicates the unavailable seconds recorded in the OTN path during the PM time interval. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-11 Chapter 15 Performance Monitoring 15.5 Performance Monitoring for Electrical Cards Table 15-3 Performance Monitoring Parameters (continued) Parameter Definition UASP-P Unavailable Seconds Path (UASP-P) is a count of one-second intervals when the DS-3 path is unavailable. A DS-3 path becomes unavailable when ten consecutive SESP-Ps occur. The ten SESP-Ps are included in unavailable time. After the DS-3 path becomes unavailable, it becomes available again when ten consecutive seconds with no SESP-Ps occur. The ten seconds with no SESP-Ps are excluded from unavailable time. UAS-SM Section Monitoring Unavailable Seconds (UAS-SM) indicates the unavailable seconds recorded in the OTN section during the PM time interval. UAS-V Unavailable Seconds VT Layer (UAS-V) is a count of the seconds when the VT path was unavailable. A VT path becomes unavailable when ten consecutive seconds occur that qualify as SES-Vs, and it continues to be unavailable until ten consecutive seconds occur that do not qualify as SES-Vs. UNC-WORDS Uncorrectable Words (UNC-WORDS) is the number of uncorrectable words detected in the DWDM trunk line during the PM time interval. VPC Valid Packets (VPC) is a count of received packets that contain non-errored data code groups that have start and end delimiters. 15.5 Performance Monitoring for Electrical Cards The following sections define PM parameters for the EC1-12, DS1/E1-56, DS1-14, DS1N-14, DS3-12, DS3-12E, DS3N-12, DS3N-12E, DS3i-N-12, DS3XM-6, DS3XM-12, and DS3/EC1-48 cards. 15.5.1 EC1-12 Card Performance Monitoring Parameters Figure 15-2 shows signal types that support near-end and far-end PMs. Figure 15-3 shows where overhead bytes detected on the application specific integrated circuits (ASICs) produce PM parameters for the EC1-12 card. Figure 15-2 Monitored Signal Types for the EC1-12 Card PTE PTE ONS 15454 ONS 15454 EC1 Signal EC1 Signal Fiber EC1 OC48 OC48 EC1 STS Path (STS XX-P) PMs Near and Far End Supported 78981 EC1 Path (EC1 XX) PMs Near and Far End Supported Cisco ONS 15454 Reference Manual, R8.5.x 15-12 78-18106-01 Chapter 15 Performance Monitoring 15.5.1 EC1-12 Card Performance Monitoring Parameters Note Figure 15-3 The XX in Figure 15-2 represents all PMs listed in Table 15-4 with the given prefix and/or suffix. PM Read Points on the EC1-12 Card ONS 15454 EC1 Card XC Card(s) OC-N LIU Tx/Rx Framer EC1 Side SONET Side CV-S ES-S SES-S SEFS-S STS CV-P STS ES-P STS FC-P STS SES-P STS UAS-P BTC CV-L SES-L ES-L UAS-L FC-L STS CV-PFE STS ES-PFE STS FC-PFE STS SES-PFE STS UAS-PFE PPJC-Pdet NPJC-Pdet PPJC-Pgen NPJC-Pgen PMs read on Framer 78982 PMs read on LIU Table 15-4 lists the PM parameters for the EC1-12 cards. Table 15-4 EC1-12 Card PMs Section (NE) Line (NE) STS Path (NE) Line (FE) STS Path (FE) CV-S ES-S SES-S SEF-S CV-L ES-L SES-L UAS-L FC-L CV-P ES-P SES-P UAS-P FC-P PPJC-PDET-P NPJC-PDET-P PPJC-PGEN-P NPJC-PGEN-P PJCS-PDET-P PJCS-PGEN-P PJC-DIFF-P CV-LFE ES-LFE SES-LFE UAS-LFE FC-LFE CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-13 Chapter 15 Performance Monitoring 15.5.2 DS1/E1-56 Card Performance Monitoring Parameters Note If the CV-L(NE and FE) falls in the range 51-61 for EC1,then, the user might see discrepancy in the SES and the UAS-L values. However, ES-L will be in the nearest accuracy. For a few seconds, in a given 10 seconds interval, the number of CV-L counted may not cross the CV count criteria for SES, (due to system/application limitation for the below mentioned ranges); as a consequence of which there may not be 10 continuous SES, thus UAS will not be observed. 15.5.2 DS1/E1-56 Card Performance Monitoring Parameters Figure 15-4 shows signal types that support near-end and far-end PMs. Figure 15-4 Monitored Signal Types for the DS1/E1-56 Card PTE PTE ONS 15454 ONS 15454 EC1 Signal EC1 Signal Fiber EC1 OC48 OC48 EC1 78981 EC1 Path (EC1 XX) PMs Near and Far End Supported STS Path (STS XX-P) PMs Near and Far End Supported Figure 15-5 shows where overhead bytes detected on the ASICs produce PM parameters for the DS1/E1-56 card. Cisco ONS 15454 Reference Manual, R8.5.x 15-14 78-18106-01 Chapter 15 Performance Monitoring 15.5.2 DS1/E1-56 Card Performance Monitoring Parameters Figure 15-5 PM Read Points on the DS1/E1-56 Card ONS 15454 High Density DS-1/E1 Card LIU Ultramapper ASIC Tx/Rx DS-1 Line PMs CV-L ES-L SES-L LOSS-L ES-L (far end) E1 Line PMs CV-L ES-L SES-L LOSS-L XC Card(s) OC-N DS-1 Path Side E-1 Path Side ES-P SAS-P UAS-P AISS-P CSS-P CV-P SAS-P ESA-P ESB-P FC-P FC-PFE AISS-P ES-P SES-P UAS-P EB-P BBE-P ESA-P SESR-P BBER-P ES-NP ES-NPFE SES-NP SES-NPFE UAS-NP UAS-NPFE ES-PFE SES-PFE UAS-PFE CSS-PFE Stingray ASIC CV-PFE ESA-PFE ESB-PFE SEFS-PFE BFDL (ES) BFDL (UAS) BFDL (BES) BFDL (SES) BFDL (CSS) BFDL LOFC) PMs read on Ultramapper ASIC and LIU 134414 This group of PMs are received from the far end. They only exist for ESF framing mode. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-15 Chapter 15 Performance Monitoring 15.5.3 DS1-14 and DS1N-14 Card Performance Monitoring Parameters Table 15-5 lists the PM parameters for the DS1/E1-56 card. Table 15-5 DS1/E1-56 Card PMs Line (NE) Line (FE) CV-L ES-L SES-L LOSS-L CV-L ES-L SES-L LOSS-L Rx Path (NE) Tx Path (NE) STS Path Rx Path (NE) (FE) AISS-P CV-P ES-P SES-P SAS-P UAS-P CSS-P ESA-P ESB-P SEFS-P AISS-P CV-P ES-P SES-P UAS-P BBER-P SESR-P ESR-P CV-P ES-P SES-P UAS-P FC-P ES-PFE ESA-PFE ESB-PFE CV-PFE CSS-PFE SEFS-PFE SES-PFE UAS-PFE STS Path (FE) Network Path BFDL (FE) CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE ES-NP ES-NPFE SES-NP SES-NPFE UAS-NP UAS-NPFE CSS ES SES BES UAS LOFC 15.5.3 DS1-14 and DS1N-14 Card Performance Monitoring Parameters Figure 15-6 shows the signal types that support near-end and far-end PMs. Figure 15-6 Monitored Signal Types for the DS1-14 and DS1N-14 Cards PTE CSU PTE CSU ONS 15454 ONS 15454 DS1 Signal DS1 Signal Fiber FDL PRM DS1 OC-N FDL PRM OC-N DS1 DS1 FDL (DS1 XX) PMs Near and Far End Supported DS1 Path (DS1 XX) PMs Near and Far End Supported 90324 VT Path (XX-V) PMs Near and Far End Supported STS Path (STS XX-P) PMs Near and Far End Supported Note The XX in Figure 15-6 represents all PMs listed in Table 15-6 with the given prefix and/or suffix. Figure 15-7 shows where overhead bytes detected on the ASICs produce PM parameters for the DS1-14 and DS1N-14 cards. Cisco ONS 15454 Reference Manual, R8.5.x 15-16 78-18106-01 Chapter 15 Performance Monitoring 15.5.3 DS1-14 and DS1N-14 Card Performance Monitoring Parameters Figure 15-7 PM Read Points on the DS1-14 and DS1N-14 Cards ONS 15454 XC Card(s) DS1 and DS1N Cards Tx/Rx OC-N LIU DS1 CV-L DS1 ES-L DS1 SES-L DS1 LOSS-L Framer DS1 Side SONET Side DS1 Rx AISS-P DS1 Rx CV-P DS1 Rx ES-P DS1 Rx SAS-P DS1 Rx SES-P DS1 Rx UAS-P DS1 Tx AISS-P DS1 Tx CV-P DS1 Tx ES-P DS1 Tx SAS-P DS1 Tx SES-P DS1 Tx UAS-P CV-V ES-V SES-V UAS-V VT Level STS CV-P STS ES-P STS FC-P STS SES-P STS UAS-P STS CV-PFE STS ES-PFE STS FC-PFE STS SES-PFE STS UAS-PFE Path Level BTC PMs read on Framer 78974 PMs read on LIU Table 15-6 describes the PM parameters for the DS1-14 and DS1N-14 cards. Table 15-6 DS1-14 and DS1N-14 Card PMs Line (NE) Line (FE) Rx Path (NE) CV-L ES-L SES-L LOSS-L CV-L ES-L Note AISS-P CV-P ES-P FC-P SAS-P SES-P UAS-P CSS-P ESA-P ESB-P SEFS-P Tx Path (NE) VT Path (NE) AISS-P CV-P ES-P FC-P SAS-P SES-P UAS-P CV-V ES-V SES-V UAS-V FC-V STS Path (NE) Rx Path (FE) CV-P ES-P SES-P UAS-P FC-P ES-PFE ESA-PFE ES-B-PFE CV-PFE CSS-PFE SEFS-PFE SES-PFE UAS-PFE VT Path (FE) STS Path (FE) CV-VFE ES-VFE SES-VFE UAS-VFE FC-VFE CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE Far-end DS1 performance monitoring values are valid only when the DS1 line is set to extended super frame (ESF). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-17 Chapter 15 Performance Monitoring 15.5.4 DS3-12 and DS3N-12 Card Performance Monitoring Parameters 15.5.3.1 DS-1 Facility Data Link Performance Monitoring Facility Data Link (FDL) performance monitoring enables an ONS 15454 DS1N-14 card to calculate and report DS-1 error rate performance measured at both the near-end and far-end of the FDL. The far-end information is reported as received on the FDL in a performance report message (PRM) from an intelligent channel service unit (CSU). To monitor DS-1 FDL PM values, the DS-1 must be set to use ESF format and the FDL must be connected to an intelligent CSU. For procedures for provisioning ESF on the DS1N-14 card, refer to the Cisco ONS 15454 Procedure Guide. The monitored DS-1 FDL PM parameters are CV-PFE, ES-PFE, ESA-PFE, ESB-PFE, SES-PFE, SEFS-PFE, CSS-PFE, UAS-PFE, FC-PFE, and ES-LFE. See Table 15-3 on page 15-5 for detailed information and definitions of specific FDL DS1 PM parameters. 15.5.4 DS3-12 and DS3N-12 Card Performance Monitoring Parameters Figure 15-8 shows the signal types that support near-end and far-end PMs. Figure 15-9 shows where overhead bytes detected on the ASICs produce PM parameters for the DS3-12 and DS3N-12 cards. Figure 15-8 Monitored Signal Types for the DS3-12 and DS3N-12 Cards PTE PTE ONS 15454 ONS 15454 DS3 Signal DS3 Signal Fiber DS3 OC-N OC-N DS3 78975 DS3 Path (DS3 XX) PMs Near and Far End Supported STS Path (STS XX-P) PMs Near and Far End Supported Note The XX in Figure 15-8 represents all PMs listed in Table 15-7 with the given prefix and/or suffix. Cisco ONS 15454 Reference Manual, R8.5.x 15-18 78-18106-01 Chapter 15 Performance Monitoring 15.5.5 DS3-12E and DS3N-12E Card Performance Monitoring Parameters Figure 15-9 PM Read Points on the DS3-12 and DS3N-12 Cards ONS 15454 XC Card(s) DS3 & DS3N Cards OC-N LIU DS3 CV-L DS3 ES-L DS3 SES-L DS3 LOSS-L Mux/Demux ASIC DS3 Side SONET Side STS CV-P STS ES-P STS FC-P STS SES-P STS UAS-P STS CV-PFE STS ES-PFE STS FC-PFE STS SES-PFE STS UAS-PFE PMs read on LIU BTC ASIC Path Level 78976 PMs read on Mux/Demux ASIC The PM parameters for the DS3-12 and DS3N-12 cards are described in Table 15-7. Table 15-7 DS3-12 and DS3N-12 Card PMs Line (NE) STS Path (NE) STS Path (FE) CV-L ES-L SES-L LOSS-L CV-P ES-P SES-P UAS-P FC-P CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE 15.5.5 DS3-12E and DS3N-12E Card Performance Monitoring Parameters Figure 15-10 shows the signal types that support near-end and far-end PMs. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-19 Chapter 15 Performance Monitoring 15.5.5 DS3-12E and DS3N-12E Card Performance Monitoring Parameters Figure 15-10 Monitored Signal Types for the DS3-12E and DS3N-12E Cards PTE PTE ONS 15454 ONS 15454 DS3 Signal DS3 Signal Fiber DS3E OC-N OC-N DS3E 78977 DS3E Path (DS3 XX) PMs Near and Far End Supported STS Path (STS XX-P) PMs Near and Far End Supported Note The XX in Figure 15-10 represents all PMs listed in Table 15-8 with the given prefix and/or suffix. Figure 15-11 shows where overhead bytes detected on the ASICs produce PM parameters for the DS3-12E and DS3N-12E cards. Figure 15-11 PM Read Points on the DS3-12E and DS3N-12E Cards ONS 15454 XC Card(s) DS3-12E & DS3N-12E Cards DS3 CV-L DS3 ES-L DS3 SES-L DS3 LOSS-L DS3 AISS-P DS3 CVP-P DS3 ESP-P DS3 SASP-P DS3 SESP-P DS3 UASP-P LIU Mux/Demux ASIC DS3 Side SONET Side STS CV-P STS ES-P STS FC-P STS SES-P STS UAS-P STS CV-PFE STS ES-PFE STS FC-PFE STS SES-PFE STS UAS-PFE DS3 CVCP-P DS3 ESCP-P DS3 SESCP-P DS3 UASCP-P DS3 CVCP-PFE DS3 ESCP-PFE DS3 SASCP-PFE DS3 SESCP-PFE DS3 UASCP-PFE OC-N BTC ASIC Path Level PMs read on Mux/Demux ASIC 78978 PMs read on LIU Table 15-8 describes the PM parameters for the DS3-12E and DS3N-12E cards. Cisco ONS 15454 Reference Manual, R8.5.x 15-20 78-18106-01 Chapter 15 Performance Monitoring 15.5.6 DS3i-N-12 Card Performance Monitoring Parameters Table 15-8 DS3-12E and DS3N-12E Card PMs Line (NE) Path (NE) STS Path (NE) Path (FE)1 STS Path (FE) CV-L ES-L SES-L LOSS-L AISS-P CV-P ES-P SAS-P2 SES-P UAS-P CVCP-P ESCP-P SASCP-P3 SESCP-P UASCP-P CV-P ES-P SES-P UAS-P FC-P CVCP-PFE ESCP-PFE SASCP-P SESCP-PFE UASCP-PFE CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE 1. The C-bit PMs (PMs that contain the text “CP-P”) are applicable only if the line format is C-bit. 2. DS3(N)-12E cards support SAS-P only on the receive (Rx) path. 3. The SASCP parameter is also displayed as "undefined" for near-end parameter though it is a far-end parameter. 15.5.6 DS3i-N-12 Card Performance Monitoring Parameters Figure 15-12 shows the signal types that support near-end and far-end PMs. Figure 15-12 Monitored Signal Types for the DS3i-N-12 Cards PTE PTE ONS 15454 ONS 15454 DS3 Signal DS3 Signal Fiber DS3i-N-12 OC-N OC-N DS3i-N-12 110718 DS3i Path (DS3 XX) PMs Near and Far End Supported STS Path (STS XX-P) PMs Near and Far End Supported Note The XX in Figure 15-12 represents all PMs listed in Table 15-9 with the given prefix and/or suffix. Figure 15-13 shows where overhead bytes detected on the ASICs produce PM parameters for the DS3i-N-12 cards. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-21 Chapter 15 Performance Monitoring 15.5.6 DS3i-N-12 Card Performance Monitoring Parameters Figure 15-13 PM Read Points on the DS3i-N-12 Cards ONS 15454 DS3i-N-12 Card DS3 CV-L DS3 ES-L DS3 SES-L DS3 LOSS-L XC Card(s) OC-N LIU Mux/Demux ASIC DS3 Side DS3 AISS-P DS3 CVP-P DS3 ESP-P DS3 SASP-P DS3 SESP-P DS3 UASP-P SONET Side BTC ASIC CV-P ES-P FC-P SES-P UAS-P DS3 CVCP-P DS3 ESCP-P DS3 SASCP-P DS3 SESCP-P DS3 UASCP-P Path Level CV-PFE ES-PFE FC-PFE SES-PFE UAS-PFE DS3 CVCP-PFE DS3 ESCP-PFE DS3 SASCP-PFE DS3 SESCP-PFE DS3 UASCP-PFE PMs read on Mux/Demux ASIC 110717 PMs read on LIU Table 15-9 describes the PM parameters for the DS3i-N-12 card. Table 15-9 DS3i-N-12 Card PMs Line (NE) Path (NE) STS Path (NE) Path (FE)1 STS Path (FE) CV-L ES-L SES-L LOSS-L AISSP-P CVP-P ESP-P SASP-P2 SESP-P UASP-P CVCP-P ESCP-P SASCP-P3 SESCP-P UASCP-P CV-P ES-P SES-P UAS-P FC-P CVCP-PFE ESCP-PFE SASCP-PFE SESCP-PFE UASCP-PFE CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE 1. The C-Bit PMs (PMs that contain the text “CP-P”) are applicable only if the line format is C-Bit. 2. DS3i-N-12 cards support SAS-P only on the Rx path. 3. The SASCP parameter is also displayed as "undefined" for near-end parameter though it is a far-end parameter. Cisco ONS 15454 Reference Manual, R8.5.x 15-22 78-18106-01 Chapter 15 Performance Monitoring 15.5.7 DS3XM-6 Card Performance Monitoring Parameters 15.5.7 DS3XM-6 Card Performance Monitoring Parameters Figure 15-14 shows the signal types that support near-end and far-end PMs. Figure 15-14 PTE Monitored Signal Types for the DS3XM-6 Card Muxed DS3 Signal ONS 15454 ONS 15454 Muxed DS3 Signal PTE Fiber DS3XM OC-N OC-N DS3XM DS1 Path (DS1 XX) PMs Near and Far End Supported DS3 Path (DS3 XX) PMs Near and Far End Supported STS Path (STS XX-P) PMs Near and Far End Supported Note 78979 VT Path (XX-V) PMs Near and Far End Supported The XX in Figure 15-14 represents all PMs listed in Table 15-10 with the given prefix and/or suffix. Figure 15-15 shows where the overhead bytes detected on the ASICs produce PM parameters for the DS3XM-6 card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-23 Chapter 15 Performance Monitoring 15.5.7 DS3XM-6 Card Performance Monitoring Parameters Figure 15-15 PM Read Points on the DS3XM-6 Card ONS 15454 XC Card(s) DS3XM-6 Card OC-N LIU DS3 CV-L DS3 ES-L DS3 SES-L DS3 LOSS-L Mapper Unit DS3 AISS-P DS3 CVP-P DS3 ESP-P DS3 SASP-P DS3 SESP-P DS3 UASP-P DS1 Side SONET Side DS1 AISS-P DS1 ES-P DS1 SAS-P DS1 SES-P DS1 UAS-P CV-V ES-V SES-V UAS-V VT Level STS CV-P STS ES-P STS FC-P STS SES-P STS UAS-P STS CV-PFE STS ES-PFE STS FC-PFE STS SES-PFE STS UAS-PFE Path Level DS3 CVCP-P DS3 ESCP-P DS3 SASCP-P DS3 SESCP-P DS3 UASCP-P DS3 CVCP-PFE DS3 ESCP-PFE DS3 SASCP-PFE DS3 SESCP-PFE DS3 UASCP-PFE BTC ASIC PMs read on Mapper Unit ASIC PMs read on LIU 78980 The DS3 path is terminated on the transmux and regenerated. Table 15-10 lists the PM parameters for the DS3XM-6 cards. Table 15-10 DS3XM-6 Card PMs DS3 Path DS3 Line (NE) (NE)1 CV-L ES-L SES-L LOSS-L AISS-P CVP-P ESP-P SASP-P2 SESP-P UASP-P ESCP-P SASCP-P3 SESCP-P UASCP-P CVCP-P DS1 Path (NE) VT Path (NE) AISS-P ES-P SAS-P2 SES-P UAS-P CV-V ES-V SES-V UAS-V DS3 Path STS Path (NE) (FE)1 CV-P ES-P SES-P UAS-P FC-P CVCP-PFE ESCP-PFE SASCP-PFE SESCP-PFE UASCP-PFE VT Path (FE) STS Path (FE) CV-VFE ES-VFE SES-VFE UAS-VFE CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE 1. The C-Bit PMs (PMs that contain the text “CP-P”) are applicable only if the line format is C-Bit. 2. DS3XM-6 cards support SAS-P only on the Rx path. 3. The SASCP parameter is also displayed as "undefined" for near-end parameter though it is a far-end parameter. Cisco ONS 15454 Reference Manual, R8.5.x 15-24 78-18106-01 Chapter 15 Performance Monitoring 15.5.8 DS3XM-12 Card Performance Monitoring Parameters 15.5.8 DS3XM-12 Card Performance Monitoring Parameters Figure 15-16 shows the signal types that support near-end and far-end PMs. Figure 15-16 PTE Monitored Signal Types for the DS3XM-12 Card Muxed DS3 Signal ONS 15454 ONS 15454 Muxed DS3 Signal PTE Fiber DS3XM OC-N OC-N DS3XM DS1 Path (DS1 XX) PMs Near and Far End Supported DS3 Path (DS3 XX) PMs Near and Far End Supported STS Path (STS XX-P) PMs Near and Far End Supported Note 78979 VT Path (XX-V) PMs Near and Far End Supported The XX in Figure 15-16 represents all PMs listed in Table 15-11 with the given prefix and/or suffix. Figure 15-17 shows where the overhead bytes detected on the ASICs produce PM parameters for the DS3XM-12 card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-25 Chapter 15 Performance Monitoring 15.5.8 DS3XM-12 Card Performance Monitoring Parameters Figure 15-17 PM Read Points on the DS3XM-12 Card ONS 15454 XC Card(s) DS3XM-12 Card OC-N LIU DS3 CV-L DS3 ES-L DS3 SES-L DS3 LOSS-L Mapper Unit DS3 AISS-P DS3 CVP-P DS3 ESP-P DS3 SASP-P DS3 SESP-P DS3 UASP-P DS1 Side SONET Side DS1 AISS-P DS1 ES-P DS1 SAS-P DS1 SES-P DS1 UAS-P CV-V ES-V SES-V UAS-V VT Level STS CV-P STS ES-P STS FC-P STS SES-P STS UAS-P STS CV-PFE STS ES-PFE STS FC-PFE STS SES-PFE STS UAS-PFE Path Level DS3 CVCP-P DS3 ESCP-P DS3 SASCP-P DS3 SESCP-P DS3 UASCP-P DS3 CVCP-PFE DS3 ESCP-PFE DS3 SASCP-PFE DS3 SESCP-PFE DS3 UASCP-PFE BTC ASIC PMs read on Mapper Unit ASIC PMs read on LIU 124556 The DS3 path is terminated on the transmux and regenerated. Table 15-11 lists the PM parameters for the DS3XM-12 cards. Table 15-11 DS3XM-12 Card PMs DS3 Path DS3 Line (NE) (NE)1 CV-L ES-L SES-L LOSS-L AISS-P CV-P ES-P SAS-P2 SES-P UAS-P ESCP-P SESCP-P UASCP-P CVCP-P DS1 Path (NE) VT Path (NE) STS Path (NE) STS Path DS3 Path (FE)1 VT Path (FE) (FE) AISS-P CV-P ES-P FC-P SAS-P2 SES-P UAS-P CSS-P ESA-P ESB-P SEFS-P CV-V ES-V SES-V UAS-V CV-P ES-P SES-P UAS-P FC-P CVCP-PFE ESCP-PFE SASCP-PFE3 SESCP-PFE UASCP-PFE CV-VFE ES-VFE SES-VFE UAS-VFE CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE BFDL (FE) CSS ES SES BES UAS LOFC 1. The C-Bit PMs (PMs that contain the text “CP-P”) are applicable only if the line format is C-Bit. 2. DS3XM-12 cards support SAS-P only on the Rx path. 3. The SASCP parameter is also displayed as "undefined" for near-end parameter though it is a far-end parameter. Cisco ONS 15454 Reference Manual, R8.5.x 15-26 78-18106-01 Chapter 15 Performance Monitoring 15.5.9 DS3/EC1-48 Card Performance Monitoring Parameters 15.5.9 DS3/EC1-48 Card Performance Monitoring Parameters Figure 15-18 shows the signal types that support near-end and far-end PMs. Figure 15-18 Monitored Signal Types for the DS3/EC1-48 Card PTE PTE ONS 15454 ONS 15454 DS3 Signal DS3 Signal Fiber DS3 OC-N OC-N DS3 STS Path (STS XX-P) PMs Near and Far End Supported Note 78975 DS3 Path (DS3 XX) PMs Near and Far End Supported The XX in Figure 15-18 represents all PMs listed in Table 15-12 with the given prefix and/or suffix. Figure 15-19 shows where the overhead bytes detected on the ASICs produce PM parameters for the DS3-EC1-48 card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-27 Chapter 15 Performance Monitoring 15.5.9 DS3/EC1-48 Card Performance Monitoring Parameters Figure 15-19 PM Read Points on the DS3/EC1-48 Card ONS 15454 XC Card(s) DS3/EC1-48 Card OC-N LIU DS3 CV-L DS3 ES-L DS3 SES-L DS3 LOSS-L Mapper Unit SONET Side DS3 AISS-P DS3 CVP-P DS3 ESP-P DS3 SASP-P DS3 SESP-P DS3 UASP-P STS CV-P STS ES-P STS FC-P STS SES-P STS UAS-P STS CV-PFE STS ES-PFE STS FC-PFE STS SES-PFE STS UAS-PFE DS3 CVCP-P DS3 ESCP-P DS3 SASCP-P DS3 SESCP-P DS3 UASCP-P DS3 CVCP-PFE DS3 ESCP-PFE DS3 SASCP-PFE DS3 SESCP-PFE DS3 UASCP-PFE BTC ASIC Path Level PMs read on Mapper Unit ASIC PMs read on LIU 124997 The DS3 path is terminated on the transmux and regenerated. Table 15-12 lists the PM parameters for the DS3/EC1-48 cards. Table 15-12 DS3/EC1-48 Card PMs DS3/EC1 Line (NE) DS3 Path (NE)1 STS Path (NE) DS3 Path (FE)1 STS Path (FE) CV-L ES-L SES-L LOSS-L AISS-P CVP-P ESP-P SASP-P2 SESP-P UASP-P ESCP-P SASCP-P3 SESCP-P UASCP-P CVCP-P CV-P ES-P SES-P UAS-P FC-P CVCP-PFE ESCP-PFE SASCP-PFE SESCP-PFE UASCP-PFE CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE 1. The C-Bit PMs (PMs that contain the text “CP-P”) are applicable only if the line format is C-Bit. 2. DS3/EC1-48 cards support SAS-P only on the Rx path. 3. The SASCP parameter is also displayed as "undefined" for near-end parameter though it is a far-end parameter. Cisco ONS 15454 Reference Manual, R8.5.x 15-28 78-18106-01 Chapter 15 Performance Monitoring 15.6 Performance Monitoring for Ethernet Cards Note If the CV-L(NE and FE) falls in the range 51-61 for DS3,then, the user might see discrepancy in the SES and the UAS-L values. However, ES-L will be in the nearest accuracy. For a few seconds, in a given 10 seconds interval, the number of CV-L counted may not cross the CV count criteria for SES, (due to system/application limitation for the below mentioned ranges); as a consequence of which there may not be 10 continuous SES, thus UAS will not be observed. 15.6 Performance Monitoring for Ethernet Cards The following sections define PM parameters and definitions for the ONS 15454 E-Series, G-Series, ML-Series, and CE-Series Ethernet cards. 15.6.1 E-Series Ethernet Card Performance Monitoring Parameters CTC provides Ethernet performance information, including line-level parameters, port bandwidth consumption, and historical Ethernet statistics. The E-Series Ethernet performance information is divided into the Statistics, Utilization, and History tabbed windows within the card view Performance tab window. 15.6.1.1 E-Series Ethernet Statistics Window The Ethernet Statistics window lists Ethernet parameters at the line level. The Statistics window provides buttons to change the statistical values shown. The Baseline button resets the displayed statistics values to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which automatic refresh occurs. Table 15-13 defines the E-Series Ethernet card statistics parameters. Table 15-13 E-Series Ethernet Statistics Parameters Parameter Definition Link Status Indicates whether link integrity is present; up means present, and down means not present. ifInOctets Number of bytes received since the last counter reset. ifInUcastPkts Number of unicast packets received since the last counter reset. ifInErrors The number of inbound packets (or transmission units) that contained errors preventing them from being deliverable to a higher-layer protocol. ifOutOctets Number of bytes transmitted since the last counter reset. ifOutUcastPkts Number of unicast packets transmitted. dot3StatsAlignmentErrors A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. dot3StatsFCSErrors A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. dot3StatsFrameTooLong A count of frames received on a particular interface that exceed the maximum permitted frame size. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-29 Chapter 15 Performance Monitoring 15.6.1 E-Series Ethernet Card Performance Monitoring Parameters Table 15-13 E-Series Ethernet Statistics Parameters (continued) Parameter Definition etherStatsUndersizePkts The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. etherStatsFragments The total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). Note It is entirely normal for etherStatsFragments to increment. This is because it counts both runts (which are normal occurrences due to collisions) and noise hits. etherStatsPkts64Octets The total number of packets (including bad packets) received that were 64 octets in length (excluding framing bits but including FCS octets). etherStatsPkts65to127 Octets The total number of packets (including bad packets) received that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts128to255 Octets The total number of packets (including bad packets) received that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts256to511 Octets The total number of packets (including bad packets) received that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts512to1023 Octets The total number of packets (including bad packets) received that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts1024to1518 The total number of packets (including bad packets) received that were Octets between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsOversizePkts The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. Note that for tagged interfaces, this number becomes 1522 bytes. etherStatsJabbers The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). etherStatsOctets The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets etherStatsCRCAlign Errors The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). Cisco ONS 15454 Reference Manual, R8.5.x 15-30 78-18106-01 Chapter 15 Performance Monitoring 15.6.1 E-Series Ethernet Card Performance Monitoring Parameters 15.6.1.2 E-Series Ethernet Utilization Window The Utilization window shows the percentage of transmit (Tx) and receive (Rx) line bandwidth used by the Ethernet ports during consecutive time segments. The Mode field displays the real-time mode status, such as 100 Full, which is the mode setting configured on the E-Series port. However, if the E-Series port is set to autonegotiate the mode (Auto), this field shows the result of the link negotiation between the E-Series and the peer Ethernet device attached directly to the E-Series port. The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas: Rx = (inOctets + inPkts * 20) * 8 / 100% interval * maxBaseRate Tx = (outOctets + outPkts * 20) * 8 / 100% interval * maxBaseRate The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the Ethernet port (that is, 1 Gbps). The maxBaseRate for E-Series Ethernet cards is shown in Table 15-14. Table 15-14 maxBaseRate for STS Circuits STS maxBaseRate STS-1 51840000 STS-3c 155000000 STS-6c 311000000 STS-12c 622000000 Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity. Note The E-Series Ethernet card is a Layer 2 device or switch and supports Trunk Utilization statistics. The Trunk Utilization statistics are similar to the Line Utilization statistics, but shows the percentage of circuit bandwidth used rather than the percentage of line bandwidth used. The Trunk Utilization statistics are accessed through the card view Maintenance tab. 15.6.1.3 E-Series Ethernet History Window The Ethernet History window lists past Ethernet statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-15. The parameters are defined in Table 15-13 on page 15-29. Table 15-15 Ethernet History Statistics per Time Interval Time Interval Number of Previous Intervals Displayed 1 minute 60 15 minutes 32 1 hour 24 1 day (24 hours) 7 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-31 Chapter 15 Performance Monitoring 15.6.2 G-Series Ethernet Card Performance Monitoring Parameters 15.6.2 G-Series Ethernet Card Performance Monitoring Parameters CTC provides Ethernet performance information, including line-level parameters, port bandwidth consumption, and historical Ethernet statistics. The G-Series Ethernet performance information is divided into the Statistics, Utilization, and History tabbed windows within the card view Performance tab window. 15.6.2.1 G-Series Ethernet Statistics Window The Ethernet Statistics window lists Ethernet parameters at the line level. The Statistics window provides buttons to change the statistical values shown. The Baseline button resets the displayed statistics values to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which automatic refresh occurs. The G-Series Statistics window also has a Clear button. The Clear button sets the values on the card to zero, but does not reset the G-Series card. Table 15-16 defines the G-Series Ethernet card statistics parameters. Table 15-16 G-Series Ethernet Statistics Parameters Parameter Definition Time Last Cleared A time stamp indicating the last time statistics were reset. Link Status Indicates whether the Ethernet link is receiving a valid Ethernet signal (carrier) from the attached Ethernet device; up means present, and down means not present. Rx Packets Number of packets received since the last counter reset. Rx Bytes Number of bytes received since the last counter reset. Tx Packets Number of packets transmitted since the last counter reset. Tx Bytes Number of bytes transmitted since the last counter reset. Rx Total Errors Total number of receive errors. Rx FCS Number of packets with a FCS error. FCS errors indicate frame corruption during transmission. Rx Alignment Number of packets with received incomplete frames. Rx Runts Measures undersized packets with bad CRC errors. Rx Shorts Measures undersized packets with good CRC errors. Rx Jabbers The total number of frames received that exceed the 1548-byte maximum and contain CRC errors. Rx Giants Number of packets received that are greater than 1530 bytes in length. Rx Pause Frames Number of received Ethernet IEEE 802.3z pause frames. Tx Pause Frames Number of transmitted IEEE 802.3z pause frames. Rx Pkts Dropped Internal Number of received packets dropped due to overflow in G-Series frame Congestion buffer. Tx Pkts Dropped Internal Number of transmit queue drops due to drops in the G-Series frame buffer. Congestion HDLC Errors High-level data link control (HDLC) errors received from SONET/SDH (see Note). Cisco ONS 15454 Reference Manual, R8.5.x 15-32 78-18106-01 Chapter 15 Performance Monitoring 15.6.2 G-Series Ethernet Card Performance Monitoring Parameters Table 15-16 Note G-Series Ethernet Statistics Parameters (continued) Parameter Definition Rx Unicast Packets Number of unicast packets received since the last counter reset. Tx Unicast Packets Number of unicast packets transmitted. Rx Multicast Packets Number of multicast packets received since the last counter reset. Tx Multicast Packets Number of multicast packets transmitted. Rx Broadcast Packets Number of broadcast packets received since the last counter reset. Tx Broadcast Packets Number or broadcast packets transmitted. Do not use the HDLC errors counter to count the number of frames dropped because of HDLC errors, because each frame can fragment into several smaller frames during HDLC error conditions and spurious HDLC frames can be generated. If HDLC error counters are incrementing when no SONET path problems should be present, it might indicate a problem with the quality of the SONET path. For example, a SONET protection switch generates a set of HDLC errors. However, the actual values of these counters are less significant than the fact that they are changing. 15.6.2.2 G-Series Ethernet Utilization Window The Utilization window shows the percentage of Tx and Rx line bandwidth used by the Ethernet ports during consecutive time segments. The Mode field displays the real-time mode status, such as 100 Full, which is the mode setting configured on the G-Series port. However, if the G-Series port is set to autonegotiate the mode (Auto), this field shows the result of the link negotiation between the G-Series and the peer Ethernet device attached directly to the G-Series port. The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas: Rx = (inOctets + inPkts * 20) * 8 / 100% interval * maxBaseRate Tx = (outOctets + outPkts * 20) * 8 / 100% interval * maxBaseRate The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the Ethernet port (that is, 1 Gbps). The maxBaseRate for G-Series Ethernet cards is shown in Table 15-14. Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity. Note Unlike the E-Series, the G-Series card does not have a display of Trunk Utilization statistics, because the G-Series card is not a Layer 2 device or switch. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-33 Chapter 15 Performance Monitoring 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters 15.6.2.3 G-Series Ethernet History Window The Ethernet History window lists past Ethernet statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-15 on page 15-31. The listed parameters are defined in Table 15-16 on page 15-32. 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters CTC provides Ethernet performance information for line-level parameters and historical Ethernet statistics. The ML-Series Ethernet performance information is divided into the Ether Ports, Packet-over-SONET (POS) Ports, and RPR Span tabbed windows within the card view Performance tab window. These tabs may vary depending on the card selected. 15.6.3.1 ML-Series Ether Ports Statistics Window The Ethernet Ether Ports Statistics window lists Ethernet parameters at the line level. The Statistics window provides buttons to change the statistical values shown. The Baseline button resets the displayed statistics values to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which automatic refresh occurs. The ML-Series Statistics window also has a Clear button. The Clear button sets the values on the card to zero, but does not reset the ML-Series card. During each automatic cycle, whether auto-refreshed or manually refreshed (using the Refresh button), statistics are added cumulatively and are not immediately adjusted to equal total received packets until testing ends. To see the final PM count totals, allow a few moments for the PM window statistics to finish testing and update fully. PM counts are also listed in the ML-Series card Performance > History window. Table 15-17 defines the ML-Series Ethernet card Ether Ports PM parameters. Table 15-17 ML-Series Ether Ports PM Parameters Parameter Definition ifInOctets Number of bytes received since the last counter reset. rxTotalPackets Number of packets received. ifInUcastPkts Number of unicast packets received since the last counter reset. ifInMulticast Pkts Number of multicast packets received since the last counter reset. ifInBroadcast Pkts Number of broadcast packets received since the last counter reset. ifInDiscards The number of inbound packets that were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. ifInErrors1 The number of inbound packets (or transmission units) that contained errors preventing them from being deliverable to a higher-layer protocol. ifOutOctets Number of bytes transmitted since the last counter reset. txTotalPkts Number of transmitted packets. ifOutUcast Pkts Number of unicast packets transmitted. ifOutMulticast Pkts Number of multicast packets transmitted. ifOutBroadcast Pkts Number or broadcast packets transmitted. Cisco ONS 15454 Reference Manual, R8.5.x 15-34 78-18106-01 Chapter 15 Performance Monitoring 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters Table 15-17 ML-Series Ether Ports PM Parameters (continued) Parameter Definition dot3StatsAlignmentErrors A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. dot3StatsFCSErrors A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. dot3StatsSingleCollisionF A count of successfully transmitted frames on a particular interface for which transmission is inhibited by exactly on collision. rames1 dot3StatsFrameTooLong1 A count of frames received on a particular interface that exceed the maximum permitted frame size. etherStatsUndersizePkts The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. etherStatsOversizePkts The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. Note that for tagged interfaces, this number becomes 1522 bytes. etherStatsFragments1 The total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). Note Note: It is entirely normal for etherStatsFragments to increment. This is because it counts both runts (which are normal occurrences due to collisions) and noise hits. etherStatsPkts64Octets1 The total number of packets (including bad packets) received that were 64 octets in length (excluding framing bits but including FCS octets). etherStatsPkts65to127Oct ets1 The total number of packets (including bad packets) received that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts128to255Oc The total number of packets (including bad packets) received that were tets1 between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts256to511Oc The total number of packets (including bad packets) received that were tets1 between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts512to1023O The total number of packets (including bad packets) received that were ctets1 between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts1024to1518 The total number of packets (including bad packets) received that were between 1024 and 1518 octets in length inclusive (excluding framing bits Octets1 but including FCS octets). etherStatsBroadcastPkts1 The total number of good packets received that were directed to the broadcast address. Note that this does not include multicast packets. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-35 Chapter 15 Performance Monitoring 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters Table 15-17 ML-Series Ether Ports PM Parameters (continued) Parameter Definition etherStatsMulticastPkts 1 The total number of good packets received that were directed to a multicast address. Note that this number does not include packets directed to the broadcast address. etherStatsJabbers The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). etherStatsOctets1 The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets. etherStatsCollissions Number of transmit packets that are collisions; the port and the attached device transmitting at the same time caused collisions. etherStatsCRCAlignError s1 The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). etherStatsDropEvents Number of received frames dropped at the port level. rx PauseFrames 2 Number of received Ethernet 802.3z pause frames. mediaIndStatsOversize Dropped2 Number of received oversized packages that are dropped. mediaIndStatsTxFrames TooLong2 Number of received frames that are too long. The maximum is the programmed max frame size (for virtual SAN [VSAN] support); if the maximum frame size is set to default, then the maximum is a 2112 byte payload plus the 36 byte header, which is a total of 2148 bytes. 1. ML-MR-10 only 2. ML1000-2 only 15.6.3.2 ML-Series Card Ether Ports Utilization Window The Ether Ports Utilization window shows the percentage of Tx and Rx line bandwidth used by the Ethernet ports during consecutive time segments. The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas: Rx = (inOctets + inPkts * 20) * 8 / 100% interval * maxBaseRate Tx = (outOctets + outPkts * 20) * 8 / 100% interval * maxBaseRate The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the Ethernet port (that is, 1 Gbps). The maxBaseRate for ML-Series Ethernet cards is shown in Table 15-14. Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity. Cisco ONS 15454 Reference Manual, R8.5.x 15-36 78-18106-01 Chapter 15 Performance Monitoring 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters 15.6.3.3 ML-Series Card Ether Ports History Window The Ethernet Ether Ports History window lists past Ethernet statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-15 on page 15-31. The listed parameters are defined in Table 15-17 on page 15-34. 15.6.3.4 ML-Series POS Ports Window In the ML-Series POS Ports window, the parameters displayed depend on the framing mode employed by the ML-Series card. The two framing modes for the POS port on the ML-Series card are HDLC and frame-mapped generic framing procedure (GFP-F). For more information on provisioning a framing mode, refer to Cisco ONS 15454 Procedure Guide. Table 15-18 defines the ML-Series Ethernet card POS Ports HDLC parameters. Table 15-19 defines the ML-Series Ethernet card POS Ports GFP-F parameters. Table 15-18 ML-Series POS Ports Parameters for HDLC Mode Parameter Definition ifInOctets Number of bytes received since the last counter reset. rxTotalPkts Number of packets received. ifOutOctets Number of bytes transmitted since the last counter reset. tx TotalPkts Number of transmitted packets. etherStatsDropEvents Number of received frames dropped at the port level. rxPktsDropped Internal Congestion Number of received packets dropped due to overflow in frame buffer. mediaIndStatsRxFrames Truncated Number of received frames with a length of 36 bytes or less. mediaIndStatsRxFrames TooLong Number of received frames that are too long. The maximum is the programmed maximum frame size (for VSAN support); if the maximum frame size is set to default, then the maximum is the 2112 byte payload plus the 36 byte header, which is a total of 2148 bytes. mediaIndStatsRxFrames BadCRC Number of received frames with CRC errors. mediaIndStatsRxShort Pkts Number of received packets that are too small. hdlcInOctets Number of bytes received (from the SONET/SDH path) prior to the bytes undergoing HLDC decapsulation by the policy engine. hdlcRxAborts Number of received packets aborted on input. hdlcOutOctets Number of bytes transmitted (to the SONET/SDH path) after the bytes undergoing HLDC encapsulation by the policy engine. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-37 Chapter 15 Performance Monitoring 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters Table 15-19 ML-Series POS Ports Parameters for GFP-F Mode Parameter Meaning etherStatsDropEvents Number of received frames dropped at the port level. rx PktsDroppedInternal Congestion Number of received packets dropped due to overflow in the frame buffer. gfpStatsRxFrame Number of received GFP frames. gfpStatsTxFrame Number of transmitted GFP frames. gfpStatsRxOctets Number of GFP bytes received. gfpStatsTxOctets Number of GFP bytes transmitted. gfpStatsRxSBitErrors Sum of all the single bit errors. In the GFP CORE HDR at the GFP-T receiver, these are correctable. gfpStatsRxMBitErrors Sum of all the multiple bit errors. In the GFP CORE HDR at the GFP-T receiver, these are uncorrectable. gfpStatsRxTypeInvalid Number of receive packets dropped due to Client Data Frame UPI errors. gfpStatsRxCRCErrors Number of packets received with a payload FCS error. gfpStatsLFDRaised Count of core HEC CRC multiple bit errors. Note This count is only of eHec multiple bit errors when in frame. This can be looked at as a count of when the state machine goes out of frame. gfpStatsCSFRaised Number of GFP Client signal fail frames detected at the GFP-T receiver. mediaIndStatsRxFrames Truncated Number of received frames that are too long. The maximum is the programmed maximum frame size (for VSAN support); if the maximum frame size is set to default, then the maximum is the 2112 byte payload plus the 36 byte header, which is a total of 2148 bytes. mediaIndStatsRxFramesTo oLong Number of received frames with CRC error.s mediaIndStatsRxShortPkts Number of received packets that are too small. 15.6.3.5 ML-Series RPR Span Window The parameters that appear in the ML-Series RPR Span window are the mandatory attributes of the 802.17 MIB. For more information on provisioning a framing mode, refer to Cisco ONS 15454 Procedure Guide. Table 15-20 defines the ML-Series Ethernet card RPR Span parameters. Table 15-20 ML-Series RPR Span Parameters for 802.17 MIB Parameter Meaning gfpStatsRxSBitErrors Sum of all the single bit errors. In the GFP CORE HDR at the GFP-T receiver, these are correctable. gfpStatsRxMBitErrors Sum of all the multiple bit errors. In the GFP CORE HDR at the GFP-T receiver, these are uncorrectable. Cisco ONS 15454 Reference Manual, R8.5.x 15-38 78-18106-01 Chapter 15 Performance Monitoring 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters Table 15-20 ML-Series RPR Span Parameters for 802.17 MIB (continued) Parameter Meaning gfpStatsRxTypeInvalid Number of receive packets dropped due to Client Data Frame UPI errors. rprSpanStatsInUcastClassC Frames Number of received (PHY to MAC) classC unicast frames. rprSpanStatsInUcastClassC Octets Number of received (PHY to MAC) classC unicast octets. rprSpanStatsInMcastClassC Frames Number of received (PHY to MAC) classC multicast and broadcast frames. rprSpanStatsInMcastClassC Octets Number of received (PHY to MAC) classC multicast and broadcast octets. rprSpanStatsInUcastClassB EirFrames Number of received (PHY to MAC) classB EIR unicast frames. rprSpanStatsInUcastClassB EirOctets Number of received (PHY to MAC) classB EIR unicast octets. rprSpanStatsInMcastClassB EirFrames Number of received (PHY to MAC) classB EIR multicast and broadcast frames. rprSpanStatsInMcastClassB EirOctets Number of received (PHY to MAC) classB EIR multicast and broadcast octets. rprSpanStatsInUcastClassB CirFrames Number of received (PHY to MAC) classB CIR unicast frames. rprSpanStatsInUcastClassB CirOctets Number of received (PHY to MAC) classB CIR unicast octets. rprSpanStatsInMcastClassB CirFrames Number of received (PHY to MAC) classB CIR multicast and broadcast frames. rprSpanStatsInMcastClassB CirOctets Number of received (PHY to MAC) classB CIR multicast and broadcast octets. rprSpanStatsInUcastClassA Frames Number of received (PHY to MAC) classA unicast frames. rprSpanStatsInUcastClassA Octets Number of received (PHY to MAC) classA unicast octets. rprSpanStatsInMcastClassA Frames Number of received (PHY to MAC) classA multicast and broadcast frames. rprSpanStatsInMcastClassA Octets Number of received (PHY to MAC) classA multicast and broadcast octets. rprSpanStatsInCtrlFrames Number of received (PHY to MAC) control frames processed by this MAC. This does not include control frames in transit, i.e. a multicast control frame received from a ringlet will be counted as In but not Out. This does not include Fairness or idle frames. rprSpanStatsInOamEcho Frames Number of received (PHY to MAC) OAM echo frames processed by this MAC. rprSpanStatsInOamFlush Frames Number of received (PHY to MAC) OAM flush frames processed by this MAC. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-39 Chapter 15 Performance Monitoring 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters Table 15-20 ML-Series RPR Span Parameters for 802.17 MIB (continued) Parameter Meaning rprSpanStatsInOamOrgFrames Number of received (PHY to MAC) OAM Org frames processed by this MAC. rprSpanStatsInTopoAtdFrames Number of received (PHY to MAC) Topology ATD frames processed by this MAC. rprSpanStatsInTopoChkSum Frames Number of received (PHY to MAC) topology rprSpanStatsInTopoTpFrames Number of received (PHY to MAC) topology TP frames processed by this MAC. rprSpanStatsOutUcastClassC Frames Number of transmitted (MAC to PHY) classC unicast frames. rprSpanStatsOutUcastClassC Octets Number of transmitted (MAC to PHY) classC unicast octets. rprSpanStatsOutMcastClassC Frames Number of transmitted (MAC to PHY) classC multicast and broadcast frames. rprSpanStatsOutMcastClassC Octets Number of transmitted (MAC to PHY) classC multicast and broadcast octets. rprSpanStatsOutUcastClassB EirFrames Number of transmitted (MAC to PHY) classB EIR unicast frames rprSpanStatsOutUcastClassB EirOctets The number of transmitted (MAC to PHY) classB EIR unicast octets. rprSpanStatsOutMcastClassB EirFrames The number of transmitted (MAC to PHY) classB EIR multicast and broadcast frames. rprSpanStatsOutMcastClassB EirOctets The number of transmitted (MAC to PHY) classB EIR multicast and broadcast octets. rprSpanStatsOutUcastClassB CirFrames The number of transmitted (MAC to PHY) classB CIR unicast frames. rprSpanStatsOutUcastClassB CirOctets The number of transmitted (MAC to PHY) classB CIR unicast octets. rprSpanStatsOutMcastClassB CirFrames The number of transmitted (MAC to PHY) classB CIR multicast and broadcast frames. rprSpanStatsOutMcastClassB CirOctets The number of transmitted (MAC to PHY) classB CIR multicast and broadcast octets. rprSpanStatsOutUcastClassA Frames The number of transmitted (MAC to PHY) classA unicast frames. rprSpanStatsOutUcastClassA Octets The number of transmitted (MAC to PHY) classA unicast octets. rprSpanStatsOutMcastClassA Frames The number of transmitted (MAC to PHY) classA multicast and broadcast frames. rprSpanStatsOutMcastClassA Octets The number of transmitted (MAC to PHY) classA multicast and broadcast octets. checksum frames processed by this MAC. Cisco ONS 15454 Reference Manual, R8.5.x 15-40 78-18106-01 Chapter 15 Performance Monitoring 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters Table 15-20 ML-Series RPR Span Parameters for 802.17 MIB (continued) Parameter Meaning rprSpanStatsOutCtrlFrames The number of transmitted (MAC to PHY) control frames generated by this MAC. This does not include control frames in transit, i.e. a multicast control frame received from a ringlet will be counted as In but not Out. This does not include Fairness or idle frames. rprSpanStatsOutOamEcho Frames The number of transmitted (MAC to PHY) OAM echo frames generated by this MAC. rprSpanStatsOutOamFlush Frames The number of transmitted (MAC to PHY) OAM flush frames generated by this MAC. rprSpanStatsOutOamOrg Frames The number of transmitted (MAC to PHY) OAM Org frames generated by this MAC. rprSpanStatsOutTopoAtd Frames The number of transmitted (MAC to PHY) topology ATD frames generated by this MAC. rprSpanStatsOutTopoChkSum Frames The number of transmitted (MAC to PHY) topology checksum frames generated by this MAC. rprSpanStatsOutTopoTp Frames The number of transmitted (MAC to PHY) topology TP frames generated by this MAC. rprClientStatsInUcastClassC Frames The number of MAC to client classC unicast frames. rprClientStatsInUcastClassC Octets The number of MAC to client classC unicast octets. rprClientStatsInMcastClassC Frames The number of MAC to client classC multicast and broadcast frames. rprClientStatsInMcastClassC Octets The number of MAC to client classC multicast and broadcast octets. rprClientStatsInUcastClassB EirFrames The number of MAC to client classB EIR unicast frames. rprClientStatsInUcastClassB EirOctets Number of packets received with a payload FCS error. rprClientStatsInMcastClassB EirFrames Number of MAC to client classB EIR multicast and broadcast frames rprClientStatsInMcastClassB EirOctets Number of MAC to client classB EIR multicast and broadcast octets. rprClientStatsInUcastClassB CirFrames Number of MAC to client classB CIR unicast frames. rprClientStatsInUcastClassB CirOctets Number of MAC to client classB CIR unicast octets. rprClientStatsInMcastClassB CirFrames Number of MAC to client classB CIR multicast and broadcast frames. rprClientStatsInMcastClassB CirOctets Number of MAC to client classB CIR multicast and broadcast octets rprClientStatsInUcastClassA Frames Number of MAC to client classA unicast frames. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-41 Chapter 15 Performance Monitoring 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters Table 15-20 ML-Series RPR Span Parameters for 802.17 MIB (continued) Parameter Meaning rprClientStatsInUcastClassA Octets Number of MAC to client classA unicast octets. rprClientStatsInMcastClassA Frames Number of MAC to client classA multicast and broadcast frames. rprClientStatsInMcastClassA Octets Number of MAC to client classA multicast and broadcast octets. rprClientStatsInBcastFrames Number of MAC to client broadcast frames. This is used only when deriving the multicast and broadcast packet counters for the interface MIB. rprClientStatsOutUcastClassC Frames Number of client to MAC classC unicast frames. rprClientStatsOutUcastClassC Octets Number of client to MAC classC unicast octets. rprClientStatsOutMcastClassC Number of client to MAC classC multicast and broadcast frames. Frames rprClientStatsOutMcastClassC Number of client to MAC classC multicast and broadcast Octets octets. rprClientStatsOutUcastClassB EirFrames Number of client to MAC classB EIR unicast rprClientStatsOutUcastClassB EirOctets Number of client to MAC classB EIR unicast frames. octets. rprClientStatsOutMcastClassB Number of client to MAC classB EIR multicast and broadcast frames. EirFrames rprClientStatsOutMcastClassB Number of client to MAC classB EIR multicast and broadcast octets. EirOctets rprClientStatsOutUcastClassB CirFrames Number of client to MAC classB CIR unicast frames. rprClientStatsOutUcastClassB CirOctets Number of client to MAC classB CIR unicast octets. rprClientStatsOutMcastClassB Number of client to MAC classB CIR multicast and broadcast CirFrames frames. rprClientStatsOutMcastClassB Number of client to MAC classB CIR multicast and broadcast octets. CirOctets rprClientStatsOutUcastClassA Frames Number of client to MAC classA unicast frames. rprClientStatsOutUcastClassA Octets Number of client to MAC classA unicast octets. rprClientStatsOutMcastClassA Number of client to MAC classA multicast and broadcast frames. Frames rprClientStatsOutMcastClassA Number of client to MAC classA multicast and broadcast octets. Octets Cisco ONS 15454 Reference Manual, R8.5.x 15-42 78-18106-01 Chapter 15 Performance Monitoring 15.6.4 CE-Series Ethernet Card Performance Monitoring Parameters Table 15-20 ML-Series RPR Span Parameters for 802.17 MIB (continued) Parameter Meaning rprClientStatsOutBcastFrames Number of client to MAC broadcast frames. This is used only when deriving the multicast and broadcast packet counters for the interface MIB. rprErrorStatsBadParityFrames Number of received (PHY to MAC) frames parity value not matching the expected parity value rprErrorStatsBadHecFrames The number of received (PHY to MAC) frames with HEC error rprErrorStatsTtlExpFrames The number of received (PHY to MAC) frames that were dropped due to zero Time To Live (TTL). rprErrorStatsTooLongFrames The number of received (PHY to MAC) frames that exceed the maximum permitted frame size. rprErrorStatsTooShortFrames The number of received (PHY to MAC) frames shortest than the minimum permitted frame size. rprErrorStatsBadFcsFrames The number of received (PHY to MAC) data and control frames where the fcs value did not match the expected fcs value. rprErrorStatsSelfSrcUcastFram The number of received (PHY to MAC) unicast frames that were es transmitted by the station itself. That is, the source MAC is equal to the interface MAC. rprErrorStatsPmdAbortFrames The number of received (PHY to MAC) frames that were aborted by the PMD. rprErrorStatsBadAddrFrames The number of received (PHY to MAC) frames with invalid SA value. rprErrorStatsContainedFrames The number of received (PHY to MAC) frames that were removed due to context containment. rprErrorStatsScffErrors The number of received (PHY to MAC) errored SCFF, with bad parity, bad FCS, or both. gpfStatsCSFRaised The number of total received client management frames. gfpStatsLFDRaised The number of Core HEC CRC Multiple Bit Errors. Note rprPortCounterError This count is only for cHEC multiple bit error when in frame. It is a count of when the state machine goes out of frame. Packets dropped internally by the network processor. 15.6.4 CE-Series Ethernet Card Performance Monitoring Parameters CTC provides Ethernet performance information, including line-level parameters, port bandwidth consumption, and historical Ethernet statistics. The CE-Series card Ethernet performance information is divided into Ether Ports and POS Ports tabbed windows within the card view Performance tab window. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-43 Chapter 15 Performance Monitoring 15.6.4 CE-Series Ethernet Card Performance Monitoring Parameters 15.6.4.1 CE-Series Card Ether Port Statistics Window The Ethernet Ether Ports Statistics window lists Ethernet parameters at the line level. The Statistics window provides buttons to change the statistical values shown. The Baseline button resets the displayed statistics values to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which automatic refresh occurs. The CE-Series Statistics window also has a Clear button. The Clear button sets the values on the card to zero, but does not reset the CE-Series card. During each automatic cycle, whether auto-refreshed or manually refreshed (using the Refresh button), statistics are added cumulatively and are not immediately adjusted to equal total received packets until testing ends. To see the final PM count totals, allow a few moments for the PM window statistics to finish testing and update fully. PM counts are also listed in the CE-Series card Performance > History window. Table 15-21 defines the CE-Series card Ethernet port parameters. Table 15-21 CE-Series Ether Port PM Parameters Parameter Definition Time Last Cleared A time stamp indicating the last time statistics were reset. Link Status Indicates whether the Ethernet link is receiving a valid Ethernet signal (carrier) from the attached Ethernet device; up means present, and down means not present. ifInOctets Number of bytes received since the last counter reset. rxTotalPkts Number of received packets. ifInUcastPkts Number of unicast packets received since the last counter reset. ifInMulticastPkts Number of multicast packets received since the last counter reset. ifInBroadcastPkts Number of broadcast packets received since the last counter reset. ifInDiscards The number of inbound packets that were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free buffer space. ifInErrors The number of inbound packets (or transmission units) that contained errors preventing them from being deliverable to a higher-layer protocol. ifOutOctets Number of bytes transmitted since the last counter reset. txTotalPkts ifOutDiscards Number of transmitted packets. 1 Number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their transmission. A possible reason for discarding such packets could be to free up buffer space. ifOutErrors1 Number of outbound packets or transmission units that could not be transmitted because of errors. ifOutUcastPkts2 ifOutMulticastPkts Number of unicast packets transmitted. 2 ifOutBroadcastPkts 2 Number of multicast packets transmitted. Number of broadcast packets transmitted. dot3StatsAlignment Errors2 A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. dot3StatsFCSErrors A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. Cisco ONS 15454 Reference Manual, R8.5.x 15-44 78-18106-01 Chapter 15 Performance Monitoring 15.6.4 CE-Series Ethernet Card Performance Monitoring Parameters Table 15-21 CE-Series Ether Port PM Parameters (continued) Parameter Definition dot3StatsSingleCollision A count of successfully transmitted frames on a particular interface for Frames2 which transmission is inhibited by exactly on collision. dot3StatsFrameTooLong A count of frames received on a particular interface that exceed the maximum permitted frame size. etherStatsUndersizePkts The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. etherStatsFragments The total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). Note It is entirely normal for etherStatsFragments to increment. This is because it counts both runts (which are normal occurrences due to collisions) and noise hits. etherStatsPkts64Octets The total number of packets (including bad packets) received that were 64 octets in length (excluding framing bits but including FCS octets). etherStatsPkts65to127 Octets The total number of packets (including bad packets) received that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts128to255 Octets The total number of packets (including bad packets) received that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts256to511 Octets The total number of packets (including bad packets) received that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts512to1023 The total number of packets (including bad packets) received that were Octets between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsPkts1024to151 The total number of packets (including bad packets) received that were 8Octets between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets). etherStatsBroadcastPkts The total number of good packets received that were directed to the broadcast address. Note that this does not include multicast packets. etherStatsMulticastPkts The total number of good packets received that were directed to a multicast address. Note that this number does not include packets directed to the broadcast address. etherStatsOversizePkts The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. Note that for tagged interfaces, this number becomes 1522 bytes. etherStatsJabbers The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-45 Chapter 15 Performance Monitoring 15.6.4 CE-Series Ethernet Card Performance Monitoring Parameters Table 15-21 CE-Series Ether Port PM Parameters (continued) Parameter Definition etherStatsOctets The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets etherStatsCollisions2 Number of transmit packets that are collisions; the port and the attached device transmitting at the same time caused collisions. etherStatsCRCAlign Errors2 The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). etherStatsDropEvents2 Number of received frames dropped at the port level. 1 Number of received pause frames. 1 Number of transmitted pause frames. rxPauseFrames txPauseFrames rxPktsDroppedInternalC ongestion1 Number of received packets dropped due to overflow in frame buffer. txPktsDroppedInternalC ongestion1 Number of transmit queue drops due to drops in frame buffer. rxControlFrames1 Number of received control frames. mediaIndStatsRxFrames Truncated1 Number of received frames with length of 36 bytes or less. mediaIndStatsRxFrames TooLong1 Number of received frames that are too long. The maximum is the programmed maximum frame size (for VSAN support); if the maximum frame size is set to default, then the maximum is the 2112 byte payload plus the 36 byte header, which is a total of 2148 bytes. mediaIndStatsRxFrames BadCRC1 Number of received frames with CRC error. mediaIndStatsTxFrames BadCRC1 Number of transmitted frames with CRC error. mediaIndStatsRxShortPk Number of received packets that are too small. ts1 1. For CE1000-4 only 2. For CE100T-8, CE-MR-10 only 15.6.4.2 CE-Series Card Ether Ports Utilization Window The Ether Ports Utilization window shows the percentage of Tx and Rx line bandwidth used by the Ethernet ports during consecutive time segments. The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas: Rx = (inOctets + inPkts * 20) * 8 / 100% interval * maxBaseRate Tx = (outOctets + outPkts * 20) * 8 / 100% interval * maxBaseRate The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the Ethernet port (that is, 1 Gbps). The maxBaseRate for CE-Series Ethernet cards is shown in Table 15-14. Cisco ONS 15454 Reference Manual, R8.5.x 15-46 78-18106-01 Chapter 15 Performance Monitoring 15.6.4 CE-Series Ethernet Card Performance Monitoring Parameters Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity. 15.6.4.3 CE-Series Card Ether Ports History Window The Ethernet Ether Ports History window lists past Ethernet statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-15 on page 15-31. The listed parameters are defined in Table 15-21 on page 15-44. 15.6.4.4 CE-Series Card POS Ports Statistics Parameters The Ethernet POS Ports statistics window lists Ethernet POS parameters at the line level. Table 15-22 defines the CE-Series Ethernet card POS Ports parameters. Table 15-22 CE-Series Card POS Ports Parameters Parameter Definition Time Last Cleared A time stamp indicating the last time that statistics were reset. Link Status Indicates whether the Ethernet link is receiving a valid Ethernet signal (carrier) from the attached Ethernet device; up means present, and down means not present. ifInOctets Number of bytes received since the last counter reset. rxTotalPkts ifInDiscards Number of received packets. 1 The number of inbound packets that were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free buffer space. ifInErrors1 The number of inbound packets (or transmission units) that contained errors preventing them from being deliverable to a higher-layer protocol. ifOutOctets Number of bytes transmitted since the last counter reset. txTotalPkts Number of transmitted packets. ifOutOversizePkts Packets greater than 1518 bytes transmitted out a port. 2 Number of received GFP frames. 2 Number of transmitted GFP frames. gfpStatsRxFrame gfpStatsTxFrame 1 gfpStatsRxCRCErrors gfpStatsRxOctets Number of packets received with a payload FCS error. 2 Number of GFP bytes received. gfpStatsTxOctets2 Number of GFP bytes transmitted. gfpStatsRxSBitErrors Sum of all the single bit errors. In the GFP CORE HDR at the GFP-T receiver, these are correctable. gfpStatsRxMBitErrors Sum of all the multiple bit errors. In the GFP CORE HDR at the GFP-T receiver, these are uncorrectable. gfpStatsRxTypeInvalid Number of receive packets dropped due to Client Data Frame UPI errors. gfpStatsRxCIDInvalid 1 Number of packets with invalid CID. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-47 Chapter 15 Performance Monitoring 15.7 Performance Monitoring for Optical Cards Table 15-22 CE-Series Card POS Ports Parameters (continued) Parameter Definition gfpStatsCSFRaised ifInPayloadCrcErrors Number of GFP Client signal fail frames detected at the GFP-T receiver. 1 Received payload CRC errors. ifOutPayloadCrcErrors1 Transmitted payload CRC errors. hdlcPktDrops Number of received packets dropped before input. 1. Applicable only for CE100T-8, CE-MR-10 2. Applicable only for CE1000-4 15.6.4.5 CE-Series Card POS Ports Utilization Window The POS Ports Utilization window shows the percentage of Tx and Rx line bandwidth used by the POS ports during consecutive time segments. The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas: Rx = (inOctets * 8) / (interval * maxBaseRate) Tx = (outOctets * 8) / (interval * maxBaseRate) The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the Ethernet port (that is, 1 Gbps). The maxBaseRate for CE-Series cards is shown in Table 15-14 on page 15-31. Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity. 15.6.4.6 CE-Series Card POS Ports History Window The Ethernet POS Ports History window lists past Ethernet POS ports statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-15 on page 15-31. The listed parameters are defined in Table 15-22 on page 15-47. 15.7 Performance Monitoring for Optical Cards This section lists PM parameters for ONS 15454 optical cards, including the OC-3, OC-12, OC-48, and OC-192 cards. Figure 15-20 shows the signal types that support near-end and far-end PMs. Cisco ONS 15454 Reference Manual, R8.5.x 15-48 78-18106-01 Chapter 15 Performance Monitoring 15.7 Performance Monitoring for Optical Cards Figure 15-20 Monitored Signal Types for the OC-3 Cards PTE PTE ONS 15454 ONS 15454 OC-3 Signal OC-3 Signal Fiber OC48 OC48 OC-3 78985 OC-3 STS Path (STS XX-P) PMs Near and Far End Supported Note The XX in Figure 15-20 represents all PMs listed in Table 15-23, Table 15-24, and Table 15-25 with the given prefix and/or suffix. Figure 15-21 shows where overhead bytes detected on the ASICs produce PM parameters for the OC3 IR 4 SH 1310 and OC3 IR SH 1310-8 cards. Figure 15-21 PM Read Points on the OC-3 Cards ONS 15454 XC Card(s) OC-3 Card OC-N Pointer Processors CV-S ES-S SES-S SEFS-S CV-L ES-L SES-L UAS-L FC-L PPJC-Pdet NPJC-Pdet PPJC-Pgen NPJC-Pgen STS CV-P STS ES-P STS FC-P STS SES-P STS UAS-P STS CV-PFE STS ES-PFE STS FC-PFE STS SES-PFE STS UAS-PFE Path Level PMs read on BTC ASIC 78986 PMs read on PMC BTC ASIC Note For PM locations relating to protection switch counts, see the Telcordia GR-253-CORE document. Table 15-23 and Table 15-24 list the PM parameters for OC-3 cards. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-49 Chapter 15 Performance Monitoring 15.7 Performance Monitoring for Optical Cards Table 15-23 OC-3 Card PMs Section (NE) Line (NE) STS Path (NE) Line (FE) STS Path (FE)1 CV-S ES-S SES-S SEF-S CV-L ES-L SES-L UAS-L FC-L PSC (1+1) PSD (1+1) CV-P ES-P SES-P UAS-P FC-P PPJC-PDET NPJC-PDET PPJC-PGEN NPJC-PGEN PPJC-PDET-P PPJC-PGEN-P PJC-DIFF CV-LFE ES-LFE SES-LFE UAS-LFE FC-LFE CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE 1. The STS Path (FE) PMs are valid only for the OC3-4 card on ONS 15454. Also, OC-3/12/48 on 15310MA platform, MRC-12, and OC192/STM64-XFP based cards support far-end path PM parameters. All other optical cards do not support far-end path PM parameters. Table 15-24 OC3-8 Card PMs Section (NE) Line (NE) CV-S ES-S SES-S SEF-S CV-L ES-L SES-L UAS-L FC-L PSC (1+1) PSD (1+1) Physical Layer (NE) LBCL OPT OPR STS Path (NE) Line (FE) STS Path (FE) CV-P ES-P SES-P UAS-P FC-P PPJC-PDET-P NPJC-PDET-P PPJC-PGEN-P NPJC-PGEN-P PJCS-PDET-P PJCS-PGEN-P PJC-DIFF-P CV-LFE ES-LFE SES-LFE UAS-LFE FC-LFE CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE Table 15-25 lists the PM parameters for OC-12, OC-48, OC-192, and OC-192-XFP cards. Cisco ONS 15454 Reference Manual, R8.5.x 15-50 78-18106-01 Chapter 15 Performance Monitoring 15.8 Performance Monitoring for Optical Multirate Cards Table 15-25 Note OC-12, OC-48, OC-192, OC-192-XFP Card PMs Section (NE) Line (NE) STS Path (NE) Line (FE) CV-S ES-S SES-S SEF-S CV-L ES-L SES--L UASL FC-L PSC (1+1, 2F BLSR) PSD (1+1, 2F BLSR) PSC-W (4F BLSR) PSD-W (4F BLSR) PSC-S (4F BLSR) PSD-S (4F BLSR) PSC-R (4F BLSR) PSD-R (4F BLSR) CV-P ES-P SES-P UAS-P FC-P PPJC-PDET-P NPJC-PDET-P PPJC-PGEN-P NPJC-PGEN-P PJCS-PGEN-P PJCS-PDET-P PJC-DIFF-P CV-L ES-L SES-L UAS-L FC-L If the CV-L(NE and FE) falls in a specific range, then, the user might see discrepancy in the SES and the UAS-L values. However, ES-L will be in the nearest accuracy. For a few seconds, in a given 10 seconds interval, the number of CV-L counted may not cross the CV count criteria for SES, (due to system/application limitation for the below mentioned ranges); as a consequence of which there may not be 10 continuous SES, thus UAS will not be observed. The corresponding (error) range for the line rates is as shown in Table 15-26. Table 15-26 Table of Border Error Rates Line Rate Error Ranges OC3 154-164 OC12 615-625 OC48 2459-2470 OC192 9835-9845 15.8 Performance Monitoring for Optical Multirate Cards This section lists PM parameters for the optical mutirate cards MRC-12 and MRC-2.5G-4. Figure 15-22 shows where overhead bytes detected on the ASICs produce PM parameters for the MRC-12 card and the MRC-2.5G-4 card. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-51 Chapter 15 Performance Monitoring 15.9 Performance Monitoring for Storage Access Networking Cards Figure 15-22 PM Read Points for the MRC-12 and the MRC-2.5G-4 Cards XC Card ONS 15454 MRC-12/MRC-2.5G-4 Multirate Cards Line PMs (SONET) Regenerator Section PM (SDH Near-End RS-EB Near-End RS-ES Near-End CV-L Near-End RS-SES Near-End ES-L Near-End RS-BBE Near-End SES-L Near-End UAS-L Near-End RS-OFS Near-End FC-L Section PM - SONET Far-End CV-LFE Near-End CV-S Far-End ES-LFE Far-End SES-LFE Near-End ES-S Far-End UAS-LFE Near-End SEFS-S Multiplex Section PM (SDH) Near-End MS-EB Near-End MS-ES Near-End MS-SES Near-End MS-UAS Near-End MS-BBE Near-End MS-FC Far-End MS-EB Far-End MS-ES Far-End MS-SES Far-End MS-UAS Far-End MS-BBE Far-End MS-FC OC-N iBPIA ASIC iBPIA ASIC 134561 PMs read on Amazon ASIC Table 15-27 lists the PM parameters for MRC-12 and MRC-4 cards. Table 15-27 MRC Card PMs Section (NE) Line (NE) Physical Layer (NE) STS Path (NE) Line (FE) STS Path (FE) CV-S ES-S SES-S SEF-S CV-L ES-L SES-L UAS-L FC-L PSC (1+1) PSD (1+1) LBC OPT OPR CV-P ES-P SES-P UAS-P FC-P PPJC-PDET-P NPJC-PDET-P PPJC-PGEN-P NPJC-PGEN-P PJCS-PDET-P PJCS-PGEN-P PJC-DIFF-P CV-LFE ES-LFE SES-LFE UAS-LFE FC-LFE CV-PFE ES-PFE SES-PFE UAS-PFE FC-PFE 15.9 Performance Monitoring for Storage Access Networking Cards The following sections define PM parameters and definitions for the SAN card, also known as the FC_MR-4 or Fibre Channel card. Cisco ONS 15454 Reference Manual, R8.5.x 15-52 78-18106-01 Chapter 15 Performance Monitoring 15.9.1 FC_MR-4 Statistics Window CTC provides FC_MR-4 performance information, including line-level parameters, port bandwidth consumption, and historical statistics. The FC_MR-4 card performance information is divided into the Statistics, Utilization, and History tabbed windows within the card view Performance tab window. 15.9.1 FC_MR-4 Statistics Window The Statistics window lists parameters at the line level. The Statistics window provides buttons to change the statistical values shown. The Baseline button resets the displayed statistics values to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which automatic refresh occurs. The Statistics window also has a Clear button. The Clear button sets the values on the card to zero. All counters on the card are cleared. Table 15-28 defines the FC_MR-4 card statistics parameters. Table 15-28 FC_MR-4 Statistics Window Parameter Definition Time Last Cleared Time stamp indicating the time at which the statistics were last reset. Link Status Indicates whether the Fibre Channel link is receiving a valid Fibre Channel signal (carrier) from the attached Fibre Channel device; up means present, and down means not present. ifInOctets Number of bytes received without error for the Fibre Channel payload. rxTotalPkts Number of Fibre Channel frames received without errors. ifInDiscards Number of inbound packets that were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. ifInErrors Sum of frames that are oversized, undersized, or with cyclic redundancy check (CRC) error. ifOutOctets Number of bytes transmitted without error for the Fibre Channel payload. txTotalPkts Number of Fibre Channel frames transmitted without errors. ifOutDiscards Number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their transmission. A possible reason for discarding such packets could be to free up buffer space. gfpStatsRxSBitErrors Number of single bit errors in core header error check (CHEC). gfpStatsRxMBitErrors Number of multiple bit errors in CHEC. gfpStatsRxTypeInvalid Number of invalid generic framing procedure (GFP) type field received. This includes unexpected user payload identifier (UPI) type and also errors in CHEC. gfpStatsRxSblkCRCErrors Number of super block CRC errors. gfpStatsRoundTripLatencyUSec Round trip delay for the end-to-end Fibre Channel transport in milli seconds. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-53 Chapter 15 Performance Monitoring 15.9.2 FC_MR-4 Utilization Window Parameter Definition gfpStatsRxDistanceExtBuffers Number of buffer credit received for GFP-T receiver (valid only if distance extension is enabled). gfpStatsTxDistanceExtBuffers Number of buffer credit transmitted for GFP-T transmitter (valid only if distance extension is enabled). mediaIndStatsRxFramesTruncated Number of Fibre Channel frames received with frame size <= 36 bytes. mediaIndStatsRxFramesTooLong Number of Fibre Channel frames received with frame size higher than the provisioned maximum frame size. mediaIndStatsRxFramesBadCRC Number of Fibre Channel frames received with bad CRC. mediaIndStatsTxFramesBadCRC Number of Fibre Channel frames transmitted with bad CRC. fcStatsLinkRecoveries Number of link recoveries. fcStatsRxCredits Number of buffers received to buffer credits T (valid only if distance extension is enable). fcStatsTxCredits Number of buffers transmitted to buffer credits T (valid only if distance extension is enable). fcStatsZeroTxCredits Number of transmit attempts that failed because of unavailable credits. 8b10bInvalidOrderedSets 8b10b loss of sync count on Fibre Channel line side. 8b10bStatsEncodingDispErrors 8b10b disparity violations count on Fibre Channel line side. gfpStatsCSFRaised Number of GFP Client Signal Fail frames detected. 15.9.2 FC_MR-4 Utilization Window The Utilization window shows the percentage of Tx and Rx line bandwidth used by the ports during consecutive time segments. The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas: Rx = (inOctets + inPkts * 24) * 8 / 100% interval * maxBaseRate Tx = (outOctets + outPkts * 24) * 8 / 100% interval * maxBaseRate The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the port (that is, 1 Gbps or 2 Gbps). The maxBaseRate for FC_MR-4 cards is shown in Table 15-29. Table 15-29 maxBaseRate for STS Circuits STS maxBaseRate STS-24 850000000 STS-48 850000000 x 21 1. For 1 Gbps of bit rate being transported, there are only 850 Mbps of actual data because of 8b->10b conversion. Similarly, for 2 Gbps of bit rate being transported, there are only 1700 Mbps (850 Mbps x 2) of actual data. Cisco ONS 15454 Reference Manual, R8.5.x 15-54 78-18106-01 Chapter 15 Performance Monitoring 15.9.3 FC_MR-4 History Window Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity. 15.9.3 FC_MR-4 History Window The History window lists past FC_MR-4 statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-30. The listed parameters are defined in Table 15-28 on page 15-53. Table 15-30 FC_MR-4 History Statistics per Time Interval Time Interval Number of Intervals Displayed 1 minute 60 previous time intervals 15 minutes 32 previous time intervals 1 hour 24 previous time intervals 1 day (24 hours) 7 previous time intervals Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 15-55 Chapter 15 Performance Monitoring 15.9.3 FC_MR-4 History Window Cisco ONS 15454 Reference Manual, R8.5.x 15-56 78-18106-01 CH A P T E R 16 SNMP This chapter explains Simple Network Management Protocol (SNMP) as implemented by the Cisco ONS 15454. For SNMP setup information, refer to the Cisco ONS 15454 Procedure Guide. Chapter topics include: • 16.1 SNMP Overview, page 16-1 • 16.2 Basic SNMP Components, page 16-2 • 16.3 SNMP External Interface Requirement, page 16-4 • 16.4 SNMP Version Support, page 16-4 • 16.5 SNMP Message Types, page 16-4 • 16.6 SNMP Management Information Bases, page 16-5 • 16.7 SNMP Trap Content, page 16-9 • 16.8 SNMP Community Names, page 16-16 • 16.9 Proxy Over Firewalls, page 16-16 • 16.10 Remote Monitoring, page 16-16 16.1 SNMP Overview SNMP is an application-layer communication protocol that allows ONS 15454 network devices to exchange management information among these systems and with other devices outside the network. Through SNMP, network administrators can manage network performance, find and solve network problems, and plan network growth. Up to 10 SNMP trap destinations and five concurrent Cisco Transport Controller (CTC) user sessions are allowed per node. The ONS 15454 uses SNMP for asynchronous event notification to a network management system (NMS). Cisco ONS system SNMP implementation uses standard Internet Engineering Task Force (IETF) management information bases (MIBs) to convey node-level inventory, fault, and performance management information for generic DS-1, DS-3, SONET, and Ethernet read-only management. SNMP allows a generic SNMP manager such as HP OpenView Network Node Manager (NNM) or Open Systems Interconnection (OSI) NetExpert to be utilized for limited management functions. The Cisco ONS 15454 supports SNMP Version 1 (SNMPv1) and SNMP Version 2c (SNMPv2c). These versions share many features, but SNMPv2c includes additional protocol operations and 64-bit performance monitoring support. This chapter describes both versions and gives SNMP configuration parameters for the ONS 15454. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-1 Chapter 16 SNMP 16.2 Basic SNMP Components Note It is recommended that the SNMP Manager timeout value be set to 60 seconds. Under certain conditions, if this value is lower than the recommended time, the TCC card can reset. However, the response time depends on various parameters such as object being queried, complexity, and number of hops in the node, etc. Note In Software Release 8.0 and later, you can retrieve automatic in service (AINS) state and soak time through the SNMP and Transaction Language One (TL1) interfaces. Note The CERENT-MSDWDM-MIB.mib, CERENT-FC-MIB.mib, and CERENT-GENERIC-PM-MIB.mib in the CiscoV2 directory support 64-bit performance monitoring counters. The SNMPv1 MIB in the CiscoV1 directory does not contain 64-bit performance monitoring counters, but supports the lower and higher word values of the corresponding 64-bit counter. The other MIB files in the CiscoV1 and CiscoV2 directories are identical in content and differ only in format. Figure 16-1 illustrates the basic layout idea of an SNMP-managed network. Basic Network Managed by SNMP 52582 Figure 16-1 16.2 Basic SNMP Components In general terms, an SNMP-managed network consists of a management system, agents, and managed devices. A management system such as HP OpenView executes monitoring applications and controls managed devices. Management systems execute most of the management processes and provide the bulk of memory resources used for network management. Additionally, a network might be managed by one or several management systems. Figure 16-2 illustrates the relationship between the network manager, the SNMP agent, and the managed devices. Cisco ONS 15454 Reference Manual, R8.5.x 16-2 78-18106-01 Chapter 16 SNMP 16.2 Basic SNMP Components Figure 16-2 Example of the Primary SNMP Components Management Entity NMS Agent Agent Management Database Management Database Management Database 33930 Agent Managed Devices An agent (such as SNMP) residing on each managed device translates local management information data—such as performance information or event and error information caught in software traps—into a readable form for the management system. Figure 16-3 illustrates SNMP agent get-requests that transport data to the network management software. NMS SNMP Manager Agent Gathering Data from a MIB and Sending Traps to the Manager Network device get, get-next, get-bulk get-response, traps MIB SNMP Agent 32632 Figure 16-3 The SNMP agent captures data from MIBs, which are device parameter and network data repositories, or from error or change traps. A managed element—such as a router, access server, switch, bridge, hub, computer host, or network element (such as an ONS 15454)—is accessed through the SNMP agent. Managed devices collect and store management information, making it available through SNMP to other management systems having the same protocol compatibility. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-3 Chapter 16 SNMP 16.3 SNMP External Interface Requirement 16.3 SNMP External Interface Requirement Since all SNMP requests come from a third-party application, the only external interface requirement is that a third-party SNMP client application should have the ability to upload RFC 3273 SNMP MIB variables in the etherStatsHighCapacityTable, etherHistoryHighCapacityTable, or mediaIndependentTable. 16.4 SNMP Version Support The ONS 15454 supports SNMPv1 and SNMPv2c traps and get requests. The ONS 15454 SNMP MIBs define alarms, traps, and status. Through SNMP, NMS applications can query a management agent for data from functional entities such as Ethernet switches and SONET multiplexers using a supported MIB. Note ONS 15454 MIB files in the CiscoV1 and CiscoV2 directories are almost identical in content except for the difference in 64-bit performance monitoring features. The CiscoV2 directory contains three MIBs with 64-bit performance monitoring counters:. CERENT-MSDWDM-MIB.mib, CERENT-FC-MIB.mib, and CERENT-GENERIC-PM-MIB.mib The CiscoV1 directory does not contain any 64-bit counters, but it does support the lower and higher word values used in 64-bit counters. The two directories also have somewhat different formats. 16.5 SNMP Message Types The ONS 15454 SNMP agent communicates with an SNMP management application using SNMP messages. Table 16-1 describes these messages. Table 16-1 ONS 15454 SNMP Message Types Operation Description get-request Retrieves a value from a specific variable. get-next-request Retrieves the value following the named variable; this operation is often used to retrieve variables from within a table. With this operation, an SNMP manager does not need to know the exact variable name. The SNMP manager searches sequentially to find the needed variable from within the MIB. get-response Replies to a get-request, get-next-request, get-bulk-request, or set-request sent by an NMS. get-bulk-request Fills the get-response with up to the max-repetition number of get-next interactions, similar to a get-next-request. set-request Provides remote network monitoring (RMON) MIB. trap Indicates that an event has occurred. An unsolicited message is sent by an SNMP agent to an SNMP manager. Cisco ONS 15454 Reference Manual, R8.5.x 16-4 78-18106-01 Chapter 16 SNMP 16.6 SNMP Management Information Bases 16.6 SNMP Management Information Bases A managed object, sometimes called a MIB object, is one of many specific characteristics of a managed device. The MIB consists of hierarchically organized object instances (variables) that are accessed by network-management protocols such as SNMP. Section 16.6.1 lists the IETF standard MIBs implemented in the ONS 15454 SNMP agent. Section 16.6.2 lists the proprietary MIBs implemented in the ONS 15454. 16.6.1 IETF-Standard MIBs for the ONS 15454 Table 16-2 lists the IETF-standard MIBs implemented in the ONS 15454 SNMP agents. You must first compile the MIBs in Table 16-2. Compile the Table 16-3 MIBs next. Caution If you do not compile MIBs in the correct order, one or more might not compile correctly. Table 16-2 IETF Standard MIBs Implemented in the ONS 15454 System RFC1 Number Module Name Title/Comments — IANAifType-MIB.mib Internet Assigned Numbers Authority (IANA) ifType 1213 RFC1213-MIB-rfc1213.mib Management Information Base for Network 1907 SNMPV2-MIB-rfc1907.mib Management of TCP/IP-based Internets: MIB-II Management Information Base for Version 2 of the Simple Network Management Protocol (SNMPv2) 1253 RFC1253-MIB-rfc1253.mib OSPF Version 2 Management Information Base 1493 BRIDGE-MIB-rfc1493.mib Definitions of Managed Objects for Bridges (This defines MIB objects for managing MAC bridges based on the IEEE 802.1D-1990 standard between Local Area Network [LAN] segments.) 2819 RMON-MIB-rfc2819.mib Remote Network Monitoring Management Information Base 2737 ENTITY-MIB-rfc2737.mib Entity MIB (Version 2) 2233 IF-MIB-rfc2233.mib Interfaces Group MIB using SNMPv2 2358 EtherLike-MIB-rfc2358.mib Definitions of Managed Objects for the Ethernet-like Interface Types 2493 PerfHist-TC-MIB-rfc2493.mib Textual Conventions for MIB Modules Using Performance History Based on 15 Minute Intervals 2495 DS1-MIB-rfc2495.mib Definitions of Managed Objects for the DS1, E1, DS2 and E2 Interface Types 2496 DS3-MIB-rfc2496.mib Definitions of Managed Object for the DS3/E3 Interface Type 2558 SONET-MIB-rfc2558.mib Definitions of Managed Objects for the SONET/SDH Interface Type Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-5 Chapter 16 SNMP 16.6.2 Proprietary ONS 15454 MIBs Table 16-2 IETF Standard MIBs Implemented in the ONS 15454 System (continued) RFC1 Number Module Name Title/Comments 2674 P-BRIDGE-MIB-rfc2674.mib Q-BRIDGE-MIB-rfc2674.mib Definitions of Managed Objects for Bridges with Traffic Classes, Multicast Filtering and Virtual LAN Extensions 3273 HC-RMON-MIB The MIB module for managing remote monitoring device implementations, augmenting the original RMON MIB as specified in RFC 2819 and RFC 1513 and RMON-2 MIB as specified in RFC 2021 1. RFC = Request for Comment 16.6.2 Proprietary ONS 15454 MIBs Each ONS 15454 is shipped with a software CD containing applicable proprietary MIBs. Table 16-3 lists the proprietary MIBs for the ONS 15454. Table 16-3 ONS 15454 Proprietary MIBs MIB Number Module Name 1 CERENT-GLOBAL-REGISTRY.mib 2 CERENT-TC.mib 3 CERENT-454.mib 4 CERENT-GENERIC.mib (not applicable to ONS 15454) 5 CISCO-SMI.mib 6 CISCO-VOA-MIB.mib 7 CERENT-MSDWDM-MIB.mib 8 CERENT-OPTICAL-MONITOR-MIB.mib 9 CERENT-HC-RMON-MIB.mib 10 CERENT-ENVMON-MIB.mib 11 CERENT-GENERIC-PM-MIB.mib Note If you cannot compile the proprietary MIBs correctly, log into the Technical Support Website at http://www.cisco.com/techsupport or call Cisco TAC (800) 553-2447. Note When SNMP indicates that a muxponder (MXP) or transponder (TXP) wavelength is unknown, it means that the corresponding card (MXP_2.5G_10E, TXP_MR_10E, MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, or TXPP_MR_2.5G) works with the first tunable wavelength. For more information about MXP and TXP cards, refer to the Cisco ONS 15454 DWDM Reference Manual. Cisco ONS 15454 Reference Manual, R8.5.x 16-6 78-18106-01 Chapter 16 SNMP 16.6.3 Generic Threshold and Performance Monitoring MIBs 16.6.3 Generic Threshold and Performance Monitoring MIBs A MIB called CERENT-GENERIC-PM-MIB allows network management stations (NMS) to use a single, generic MIB for accessing threshold and performance monitoring data of different interface types. The MIB is generic in the sense that it is not tied to any particular kind of interface. The MIB objects can be used to obtain threshold values, current performance monitoring (PM) counts, and historic PM statistics for each kind of monitor and any supported interval at the near end and far end. Previously existing MIBs in the ONS 15454 system provide some of these counts. For example, SONET interface 15-minute current PM counts and historic PM statistics are available using the SONET-MIB. DS-1 and DS-3 counts and statistics are available through the DS1-MIB and DS-3 MIB respectively. The generic MIB provides these types of information and also fetches threshold values and single-day statistics. In addition, the MIB supports optics and dense wavelength division multiplexing (DWDM) threshold and performance monitoring information. The CERENT-GENERIC-PM-MIB is organized into three different tables: • cerentGenericPmThresholdTable • cerentGenericPmStatsCurrentTable • cerentGenericPmStatsIntervalTable • The cerentGenericPmThresholdTable is used to obtain the threshold values for the monitor types. It is indexed based on the following items: • Interface index (cerentGenericPmThresholdIndex) • Monitor type (cerentGenericPmThresholdMonType). The syntax of cerentGenericPmThresholdMonType is type cerentMonitorType, defined in CERENT-TC.mib. • Location (cerentGenericPmThresholdLocation). The syntax of cerentGenericPmThresholdLocation is type cerentLocation, defined in CERENT-TC.mib. • Time period (cerentGenericPmThresholdPeriod). The syntax of cerentGenericPmThresholdPeriod is type cerentPeriod, defined in CERENT-TC.mib. Threshold values can be provided in 64-bit and 32-bit formats. (For more information about 64-bit counters, see the “16.10.2 HC-RMON-MIB Support” section on page 16-18.) The 64-bit values in cerentGenericPmThresholdHCValue can be used with agents that support SNMPv2. The two 32-bit values (cerentGenericPmThresholdValue and cerentGenericPmThresholdOverFlowValue) can be used by NMSs that only support SNMPv1. The objects compiled in the cerentGenericPmThresholdTable are shown in Table 16-4. Table 16-4 cerentGenericPmThresholdTable Index Objects Information Objects cerentGenericPmThresholdIndex cerentGenericPmThresholdValue cerentGenericPmThresholdMonType cerentGenericPmThresholdOverFlowValue cerentGenericPmThresholdLocation cerentGenericPmThresholdHCValue cerentGenericPmThresholdPeriod — The second table within the MIB, cerentGenericPmStatsCurrentTable, compiles the current performance monitoring (PM) values for the monitor types. The table is indexed based on interface index (cerentGenericPmStatsCurrentIndex), monitor type (cerentGenericPmStatsCurrentMonType), location (cerentGenericPmStatsCurrentLocation) and time period (cerentGenericPmStatsCurrentPeriod). The Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-7 Chapter 16 SNMP 16.6.3 Generic Threshold and Performance Monitoring MIBs syntax of cerentGenericPmStatsCurrentIndex is type cerentLocation, defined in CERENT-TC.mib. The syntax of cerentGenericPmStatsCurrentMonType is type cerentMonitor, defined in CERENT-TC.mib. The syntax of cerentGenericPmStatsCurrentPeriod is type cerentPeriod, defined in CERENT-TC.mib. The cerentGenericPmStatsCurrentTable validates the current PM value using the cerentGenericPmStatsCurrentValid object and registers the number of valid intervals with historical PM statistics in the cerentGenericPmStatsCurrentValidIntervals object. PM values are provided in 64-bit and 32-bit formats. The 64-bit values in cerentGenericPmStatsCurrentHCValue can be used with agents that support SNMPv2. The two 32-bit values (cerentGenericPmStatsCurrentValue and cerentGenericPmStatsCurrentOverFlowValue) can be used by NMS that only support SNMPv1. The cerentGenericPmStatsCurrentTable is shown in Table 16-5. Table 16-5 32-Bit cerentGenericPmStatsCurrentTable Index Objects Informational Objects cerentGenericPmStatsCurrentIndex cerentGenericPmStatsCurrentValue cerentGenericPmStatsCurrentMonType cerentGenericPmStatsCurrentOverFlowValue cerentGenericPmStatsCurrentLocation cerentGenericPmStatsCurrentHCValue cerentGenericPmStatsCurrentPeriod cerentGenericPmStatsCurrentValidData — cerentGenericPmStatsCurrentValidIntervals The third table in the MIB, cerentGenericPmStatsIntervalTable, obtains historic PM values for the monitor types. It validates the current PM value in the cerentGenericPmStatsIntervalValid object. This table is indexed based on interface index (cerentGenericPmStatsIntervalIndex), monitor type (cerentGenericPMStatsIntervalMonType), location (cerentGenericPmStatsIntervalLocation), and period (cerentGenericPmStatsIntervalPeriod). The syntax of cerentGenericPmStatsIntervalIndex is type cerentLocation, defined in CERENT-TC.mib. The syntax of cerentGenericPmStatsIntervalMonType is type cerentMonitor, defined in CERENT-TC.mib. The syntax of cerentGernicPmStatsIntervalPeriod is type cerentPeriod, defined in CERENT-TC.mib. The table provides historic PM values in 64-bit and 32-bit formats. The 64-bit values contained in the cerentGenericPmStatsIntervalHCValue table can be used with SNMPv2 agents. The two 32-bit values (cerentGenericPmStatsIntervalValue and cerentGenericPmStatsIntervalOverFlowValue) can be used by SNMPv1 NMS. The cerentGenericPmStatsIntervalTable is shown in Table 16-6. Table 16-6 32-Bit cerentGenericPmStatsIntervalTable Index Objects Informational Objects cerentGenericPmStatsIntervalIndex cerentGenericPmStatsIntervalValue cerentGenericPmStatsIntervalMonType cerentGenericPmStatsIntervalOverFlowValue cerentGenericPmStatsIntervalLocation cerentGenericPmStatsIntervalHCValue cerentGenericPmStatsIntervalPeriod cerentGenericPmStatsIntervalValidData cerentGenericPmStatsIntervalNumber — Cisco ONS 15454 Reference Manual, R8.5.x 16-8 78-18106-01 Chapter 16 SNMP 16.7 SNMP Trap Content 16.7 SNMP Trap Content The ONS 15454 uses SNMP traps to generate all alarms and events, such as raises and clears. The traps contain the following information: • Object IDs that uniquely identify each event with information about the generating entity (the slot or port; synchronous transport signal [STS] and Virtual Tributary [VT]; bidirectional line switched ring [BLSR], Spanning Tree Protocol [STP], etc.). • Severity and service effect of the alarm (critical, major, minor, or event; service-affecting or non-service-affecting). • Date and time stamp showing when the alarm occurred. 16.7.1 Generic and IETF Traps The ONS 15454 supports the generic IETF traps listed in Table 16-7. Table 16-7 Supported Generic IETF Traps Trap From RFC No. MIB coldStart RFC1907-MIB Agent up, cold start. warmStart RFC1907-MIB Agent up, warm start. authenticationFailure RFC1907-MIB Community string does not match. newRoot RFC1493/ Description Sending agent is the new root of the spanning tree. BRIDGE-MIB topologyChange RFC1493/ BRIDGE-MIB A port in a bridge has changed from Learning to Forwarding or Forwarding to Blocking. entConfigChange RFC2737/ ENTITY-MIB The entLastChangeTime value has changed. dsx1LineStatusChange RFC2495/ DS1-MIB The value of an instance of dsx1LineStatus has changed. The trap can be used by an NMS to trigger polls. When the line status change results from a higher-level line status change (for example, a DS-3), no traps for the DS-1 are sent. dsx3LineStatusChange RFC2496/ DS3-MIB The value of an instance of dsx3LineStatus has changed. This trap can be used by an NMS to trigger polls. When the line status change results in a lower-level line status change (for example, a DS-1), no traps for the lower-level are sent. risingAlarm RFC2819/ RMON-MIB The SNMP trap that is generated when an alarm entry crosses the rising threshold and the entry generates an event that is configured for sending SNMP traps. fallingAlarm RFC2819/ RMON-MIB The SNMP trap that is generated when an alarm entry crosses the falling threshold and the entry generates an event that is configured for sending SNMP traps. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-9 Chapter 16 SNMP 16.7.2 Variable Trap Bindings 16.7.2 Variable Trap Bindings Each SNMP trap contains variable bindings that are used to create the MIB tables. ONS 15454 traps and variable bindings are listed in Table 16-8. For each group (such as Group A), all traps within the group are associated with all of its variable bindings. Table 16-8 Group A B Supported ONS 15454 SNMPv2 Trap Variable Bindings Variable Trap Name(s) Associated Binding with Number dsx1LineStatusChange (from RFC 2495) dsx3LineStatusChange (from RFC 2496) SNMPv2 Variable Bindings Description (1) dsx1LineStatus This variable indicates the line status of the interface. It contains loopback, failure, received alarm and transmitted alarm information. (2) dsx1LineStatusLastChange The value of MIB II’s sysUpTime object at the time this DS1 entered its current line status state. If the current state was entered prior to the last proxy-agent reinitialization, the value of this object is zero. (3) cerent454NodeTime The time that an event occurred. (4) cerent454AlarmState The alarm severity and service-affecting status. Severities are Minor, Major, and Critical. Service-affecting statuses are Service-Affecting and Non-Service Affecting. (5) snmpTrapAddress The address of the SNMP trap. (1) dsx3LineStatus This variable indicates the line status of the interface. It contains loopback state information and failure state information. (2) dsx3LineStatusLastChange The value of MIB II's sysUpTime object at the time this DS3/E3 entered its current line status state. If the current state was entered prior to the last reinitialization of the proxy-agent, then the value is zero. (3) cerent454NodeTime The time that an event occurred. Cisco ONS 15454 Reference Manual, R8.5.x 16-10 78-18106-01 Chapter 16 SNMP 16.7.2 Variable Trap Bindings Table 16-8 Group Supported ONS 15454 SNMPv2 Trap Variable Bindings (continued) Variable Trap Name(s) Associated Binding with Number SNMPv2 Variable Bindings Description (4) cerent454AlarmState The alarm severity and service-affecting status. Severities are Minor, Major, and Critical. Service-affecting statuses are Service-Affecting and Non-Service Affecting. (5) snmpTrapAddress The address of the SNMP trap. coldStart (from RFC 1907) (1) cerent454NodeTime The time that the event occurred. warmStart (from RFC 1907) (2) cerent454AlarmState The alarm severity and service-affecting status. Severities are Minor, Major, and Critical. Service-affecting statuses are Service-Affecting and Non-Service Affecting. newRoot (from RFC) (3) snmpTrapAddress The address of the SNMP trap. topologyChange (from RFC) — — entConfigChange (from RFC 2737) — — authenticationFailure (from RFC 1907) — — (1) alarmIndex This variable uniquely identifies each entry in the alarm table. When an alarm in the table clears, the alarm indexes change for each alarm listed. (2) alarmVariable The object identifier of the variable being sampled. (3) alarmSampleType The method of sampling the selected variable and calculating the value to be compared against the thresholds. (4) alarmValue The value of the statistic during the last sampling period. B (cont.) C D1 risingAlarm (from RFC 2819) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-11 Chapter 16 SNMP 16.7.2 Variable Trap Bindings Table 16-8 Group D1 (cont.) D2 Supported ONS 15454 SNMPv2 Trap Variable Bindings (continued) Variable Trap Name(s) Associated Binding with Number SNMPv2 Variable Bindings Description (5) alarmRisingThreshold When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event is generated. A single event is also generated if the first sample after this entry is greater than or equal to this threshold. (6) cerent454NodeTime The time that an event occurred. (7) cerent454AlarmState The alarm severity and service-affecting status. Severities are Minor, Major, and Critical. Service-affecting statuses are Service-Affecting and Non-Service Affecting. (8) snmpTrapAddress The address of the SNMP trap. alarmIndex This variable uniquely identifies each entry in the alarm table. When an alarm in the table clears, the alarm indexes change for each alarm listed. (2) alarmVariable The object identifier of the variable being sampled. (3) alarmSampleType The method of sampling the selected variable and calculating the value to be compared against the thresholds. (4) alarmValue The value of the statistic during the last sampling period. (5) alarmFallingThreshold When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event is generated. A single is also generated if the first sample after this entry is less than or equal to this threshold. (6) cerent454NodeTime The time that an event occurred. fallingAlarm (from RFC (1) 2819) Cisco ONS 15454 Reference Manual, R8.5.x 16-12 78-18106-01 Chapter 16 SNMP 16.7.2 Variable Trap Bindings Table 16-8 Group Supported ONS 15454 SNMPv2 Trap Variable Bindings (continued) Variable Trap Name(s) Associated Binding with Number D2 (cont.) E failureDetectedExternal ToTheNE (from CERENT-454-mib) SNMPv2 Variable Bindings Description (7) cerent454AlarmState The alarm severity and service-affecting status. Severities are Minor, Major, and Critical. Service-affecting statuses are Service-Affecting and Non-Service Affecting. (8) snmpTrapAddress The address of the SNMP trap. (1) cerent454NodeTime The time that an event occurred. (2) cerent454AlarmState The alarm severity and service-affecting status. Severities are Minor, Major, and Critical. Service-affecting statuses are Service-Affecting and Non-Service Affecting. (3) cerent454AlarmObjectType The entity that raised the alarm. The NMS should use this value to decide which table to poll for further information about the alarm. (4) cerent454AlarmObjectIndex Every alarm is raised by an object entry in a specific table. This variable is the index of objects in each table; if the alarm is interface-related, this is the index of the interface in the interface table. (5) cerent454AlarmSlotNumber The slot of the object that raised the alarm. If a slot is not relevant to the alarm, the slot number is zero. (6) cerent454AlarmPortNumber The port of the object that raised the alarm. If a port is not relevant to the alarm, the port number is zero. (7) cerent454AlarmLineNumber The object line that raised the alarm. If a line is not relevant to the alarm, the line number is zero. (8) cerent454AlarmObjectName The TL1-style user-visible name that uniquely identifies an object in the system. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-13 Chapter 16 SNMP 16.7.2 Variable Trap Bindings Table 16-8 Group Supported ONS 15454 SNMPv2 Trap Variable Bindings (continued) Variable Trap Name(s) Associated Binding with Number E (cont.) F performanceMonitor ThresholdCrossingAlert (from CERENT-454-mib) SNMPv2 Variable Bindings Description (9) cerent454AlarmAdditionalInfo Additional information for the alarm object. In the current version of the MIB, this object contains provisioned description for alarms that are external to the NE. If there is no additional information, the value is zero. (10) snmpTrapAddress The address of the SNMP trap. (1) cerent454NodeTime The time that an event occurred. (2) cerent454AlarmState The alarm severity and service-affecting status. Severities are Minor, Major, and Critical. Service-affecting statuses are Service-Affecting and Non-Service Affecting. (3) cerent454AlarmObjectType The entity that raised the alarm. The NMS should use this value to decide which table to poll for further information about the alarm. (4) cerent454AlarmObjectIndex Every alarm is raised by an object entry in a specific table. This variable is the index of objects in each table; if the alarm is interface-related, this is the index of the interface in the interface table. (5) cerent454AlarmSlotNumber The slot of the object that raised the alarm. If a slot is not relevant to the alarm, the slot number is zero. (6) cerent454AlarmPortNumber The port of the object that raised the alarm. If a port is not relevant to the alarm, the port number is zero. (7) cerent454AlarmLineNumber The object line that raised the alarm. If a line is not relevant to the alarm, the line number is zero. (8) cerent454AlarmObjectName The TL1-style user-visible name that uniquely identifies an object in the system. (9) cerent454ThresholdMonitorType This object indicates the type of metric being monitored. Cisco ONS 15454 Reference Manual, R8.5.x 16-14 78-18106-01 Chapter 16 SNMP 16.7.2 Variable Trap Bindings Table 16-8 Group Supported ONS 15454 SNMPv2 Trap Variable Bindings (continued) Variable Trap Name(s) Associated Binding with Number F (cont.) G All other traps (from CERENT-454-MIB) not listed above SNMPv2 Variable Bindings Description (10) cerent454ThresholdLocation Indicates whether the event occurred at the near or far end. (11) cerent454ThresholdPeriod Indicates the sampling interval period. (12) cerent454ThresholdSetValue The value of this object is the threshold provisioned by the NMS. (13) cerent454ThresholdCurrentValue — (14) cerent454ThresholdDetectType — (15) snmpTrapAddress The address of the SNMP trap. (1) cerent454NodeTime The time that an event occurred. (2) cerent454AlarmState The alarm severity and service-affecting status. Severities are Minor, Major, and Critical. Service-affecting statuses are Service-Affecting and Non-Service Affecting. (3) cerent454AlarmObjectType The entity that raised the alarm. The NMS should use this value to decide which table to poll for further information about the alarm. (4) cerent454AlarmObjectIndex Every alarm is raised by an object entry in a specific table. This variable is the index of objects in each table; if the alarm is interface-related, this is the index of the interface in the interface table. (5) cerent454AlarmSlotNumber The slot of the object that raised the alarm. If a slot is not relevant to the alarm, the slot number is zero. (6) cerent454AlarmPortNumber The port of the object that raised the alarm. If a port is not relevant to the alarm, the port number is zero. (7) cerent454AlarmLineNumber The object line that raised the alarm. If a line is not relevant to the alarm, the line number is zero. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-15 Chapter 16 SNMP 16.8 SNMP Community Names Table 16-8 Group Supported ONS 15454 SNMPv2 Trap Variable Bindings (continued) Variable Trap Name(s) Associated Binding with Number G (cont.) SNMPv2 Variable Bindings Description (8) cerent454AlarmObjectName The TL1-style user-visible name that uniquely identifies an object in the system. (9) snmpTrapAddress The address of the SNMP trap. 16.8 SNMP Community Names Community names are used to group SNMP trap destinations. All ONS 15454 trap destinations can be provisioned as part of SNMP communities in CTC. When community names are assigned to traps, the ONS 15454 treats the request as valid if the community name matches one that is provisioned in CTC. In this case, all agent-managed MIB variables are accessible to that request. If the community name does not match the provisioned list, SNMP drops the request. 16.9 Proxy Over Firewalls SNMP and NMS applications have traditionally been unable to cross firewalls used for isolating security risks inside or from outside networks. CTC enables network operations centers (NOCs) to access performance monitoring data such as RMON statistics or autonomous messages across firewalls by using an SNMP proxy element installed on a firewall. The application-level proxy transports SNMP protocol data units (PDU) between the NMS and NEs, allowing requests and responses between the NMS and NEs and forwarding NE autonomous messages to the NMS. The proxy agent requires little provisioning at the NOC and no additional provisioning at the NEs. The firewall proxy is intended for use in a gateway network element-end network element (GNE-ENE) topology with many NEs through a single NE gateway. Up to 64 SNMP requests (such as get, getnext, or getbulk) are supported at any time behind single or multiple firewalls. The proxy interoperates with common NMS such as HP OpenView. For security reasons, the SNMP proxy feature must be enabled at all receiving and transmitting NEs to function. For instructions to do this, refer to the Cisco ONS 15454 Procedure Guide. 16.10 Remote Monitoring The ONS 15454 incorporates RMON to allow network operators to monitor Ethernet card performance and events. The RMON thresholds are user-provisionable in CTC. Refer to the Cisco ONS 15454 Procedure Guide for instructions. Note Typical RMON operations, other than threshold provisioning, are invisible to the CTC user. Cisco ONS 15454 Reference Manual, R8.5.x 16-16 78-18106-01 Chapter 16 SNMP 16.10.1 64-Bit RMON Monitoring over DCC ONS 15454 system RMON is based on the IETF-standard MIB RFC 2819 and includes the following five groups from the standard MIB: Ethernet Statistics, History Control, Ethernet History, Alarm, and Event. Certain statistics measured on the ML card are mapped to standard MIB if one exists else mapped to a non standard MIB variable. The naming convention used by the standarad/non-standard MIB is not the same as the statistics variable used by the card. Hence when these statistics are obtained via get-reques/get-next-request/SNMP Trap they don’t match the name used on the card or as seen by CTC/TL1. • For ex: STATS_MediaIndStatsRxFramesTooLong stats is mapped to cMediaIndependentInFramesTooLong variable in CERENT MIB. STATS_RxTotalPkts is mapped to mediaIndependentInPkts in HC-RMON-rfc3273.mib 16.10.1 64-Bit RMON Monitoring over DCC The ONS 15454 DCC is implemented over the IP protocol, which is not compatible with Ethernet. The system builds Ethernet equipment History and Statistics tables using high data level control (HDLC) statistics that are gathered over the data communications channel (DCC) that is running point-to-point protocol (PPP). RMON DCC monitors the health of remote DCC connections for IP and Ethernet. RMON DCC contains two MIBS for DCC interfaces. They are: • cMediaIndependentTable—standard, RFC3273; the proprietary extension of the HC-RMON MIB used for reporting statistics • cMediaIndependentHistoryTable—proprietary MIB used to support history 16.10.1.1 Row Creation in MediaIndependentTable The SetRequest PDU contains all needed values to activate a row of the mediaIndependentTable in a single operation as well as assign the status variable to createRequest (2). In order to create the row and status, the SetRequest PDU for entry creation must have a value of zero for each of the object IDs. That is, all object IDs (OIDs) should be of the type OID.0. In order to create a row, the SetRequest PDU should contain the following: • mediaIndependentDataSource and its desired value • mediaIndependentOwner and its desired value (up to 32 characters ) • mediaIndependentStatus with a value of createRequest (2) The mediaIndependentTable creates a row if the SetRequest PDU is valid according to these rules. The SNMP agent decides the value of mediaIndependentIndex when the row is created, and a value can change if an Ethernet interface is added or deleted. The values are not sequentially allotted or contiguously numbered. The newly created row will have an mediaIndependentTable value of valid (1). If the row already exists, or if the SetRequest PDU values are insufficient or do not make sense, the SNMP agent returns an error code. Note mediaIndependentTable entries are not preserved if the SNMP agent is restarted. The mediaIndependentTable deletes a row if the SetRequest PDU contains a mediaIndependentStatus with a value of invalid (4). The varbind’s OID instance value identifies the row for deletion. You can recreate a deleted row in the table if desired. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-17 Chapter 16 SNMP 16.10.2 HC-RMON-MIB Support 16.10.1.2 Row Creation in cMediaIndependentHistoryControlTable SNMP row creation and deletion for the cMediaIndependentHistoryControlTable follows the same processes as for the MediaIndependentTable; only the variables differ. In order to create a row, the SetRequest PDU should contain the following: • cMediaIndependentHistoryControlDataSource and its desired value • cMediaIndependentHistoryControlOwner and its desired value • cMediaIndependentHistoryControlStatus with a value of createRequest (2) 16.10.2 HC-RMON-MIB Support For the ONS 15454, the implementation of the high-capacity remote monitoring information base (HC-RMON-MIB, or RFC 3273) enables 64-bit support of existing RMON tables. This support is provided with the etherStatsHighCapacityTable and the etherHistoryHighCapacityTable. An additional table, the mediaIndependentTable, and an additional object, hcRMONCapabilities, are also added for this support. All of these elements are accessible by any third-party SNMP client should have the ability to upload RFC 3273 SNMP MIB variables in the etherStatsHighCapacityTable, etherHistoryHighCapacityTable, or mediaIndependentTable. 16.10.3 Ethernet Statistics RMON Group The Ethernet Statistics group contains the basic statistics monitored for each subnetwork in a single table called the etherStatsTable. 16.10.3.1 Row Creation in etherStatsTable The SetRequest PDU for creating a row in this table contains all needed values to activate a table row in a single operation as well as assign the status variable to createRequest. The SetRequest PDU OID) entries must have an instance value, or type OID, of 0. In order to create a row, the SetRequest PDU should contain the following: • The etherStatsDataSource and its desired value • The etherStatsOwner and its desired value (up to 32 characters) • The etherStatsStatus with a value of createRequest (2) The etherStatsTable creates a row if the SetRequest PDU is valid according to these rules. The SNMP agent decides the value of etherStatsIndex when the row is created and this value changes when an Ethernet interface is added or deleted; it is not sequentially allotted or contiguously numbered. A newly created row will have an etherStatsStatus value of valid (1). If the etherStatsTable row already exists, or if the SetRequest PDU values are insufficient or do not make sense, the SNMP agent returns an error code. Note EtherStatsTable entries are not preserved if the SNMP agent is restarted. Cisco ONS 15454 Reference Manual, R8.5.x 16-18 78-18106-01 Chapter 16 SNMP 16.10.4 History Control RMON Group 16.10.3.2 Get Requests and GetNext Requests Get requests and getNext requests for the etherStatsMulticastPkts and etherStatsBroadcastPkts columns return a value of zero because the variables are not supported by ONS 15454 Ethernet cards. 16.10.3.3 Row Deletion in etherStatsTable To delete a row in the etherStatsTable, the SetRequest PDU should contain an etherStatsStatus “invalid” value (4). The OID marks the row for deletion. If required, a deleted row can be recreated. 16.10.3.4 64-Bit etherStatsHighCapacityTable The Ethernet statistics group contains 64-bit statistics in the etherStatsHighCapacityTable, which provides 64-bit RMON support for the HC-RMON-MIB. The etherStatsHighCapacityTable is an extension of the etherStatsTable that adds 16 new columns for performance monitoring data in 64-bit format. There is a one-to-one relationship between the etherStatsTable and etherStatsHighCapacityTable when rows are created or deleted in either table. 16.10.4 History Control RMON Group The History Control group defines sampling functions for one or more monitor interfaces in the historyControlTable. The values in this table, as specified in RFC 2819, are derived from the historyControlTable and etherHistoryTable. 16.10.4.1 History Control Table The RMON is sampled at one of four possible intervals. Each interval, or period, contains specific history values called buckets. Table 16-9 lists the four sampling periods and corresponding buckets. The historyControlTable maximum row size is determined by multiplying the number of ports on a card by the number of sampling periods. For example, an ONS 15454 E100 card contains 24 ports, which multiplied by periods allows 96 rows in the table. An E1000 card contains 14 ports, which multiplied by four periods allows 56 table rows. Table 16-9 RMON History Control Periods and History Categories Sampling Periods (historyControlValue Variable) Total Values, or Buckets (historyControl Variable) 15 minutes 32 24 hours 7 1 minute 60 60 minutes 24 16.10.4.2 Row Creation in historyControlTable To activate a historyControlTable row, the SetRequest PDU must contain all needed values and have a status variable value of 2 (createRequest). All OIDs in the SetRequest PDU should be type OID.0 for entry creation. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-19 Chapter 16 SNMP 16.10.5 Ethernet History RMON Group To create a SetRequest PDU for the historyControlTable, the following values are required: • The historyControlDataSource and its desired value • The historyControlBucketsRequested and it desired value • The historyControlInterval and its desired value • The historyControlOwner and its desired value • The historyControlStatus with a value of createRequest (2) The historyControlBucketsRequested OID value is ignored because the number of buckets allowed for each sampling period, based upon the historyControlInterval value, is already fixed as listed in Table 16-9. The historyControlInterval value cannot be changed from the four allowed choices. If you use another value, the SNMP agent selects the closest smaller time period from the set buckets. For example, if the set request specifies a 25-minute interval, this falls between the 15-minute (32 bucket) variable and the 60-minute (24 bucket) variable. The SNMP agent automatically selects the lower, closer value, which is 15 minutes, so it allows 32 buckets. If the SetRequest PDU is valid, a historyControlTable row is created. If the row already exists, or if the SetRequest PDU values do not make sense or are insufficient, the SNMP agent does not create the row and returns an error code. 16.10.4.3 Get Requests and GetNext Requests These PDUs are not restricted. 16.10.4.4 Row Deletion in historyControl Table To delete a row from the table, the SetRequest PDU should contain a historyControlStatus value of 4 (invalid). A deleted row can be recreated. 16.10.5 Ethernet History RMON Group The ONS 15454 implements the etherHistoryTable as defined in RFC 2819. The group is created within the bounds of the historyControlTable and does not deviate from the RFC in its design. 16.10.5.1 64-Bit etherHistoryHighCapacityTable 64-bit Ethernet history for the HC-RMON-MIB is implemented in the etherHistoryHighCapacityTable, which is an extension of the etherHistoryTable. The etherHistoryHighCapacityTable adds four columns for 64-bit performance monitoring data. These two tables have a one-to-one relationship. Adding or deleting a row in one table will effect the same change in the other. 16.10.6 Alarm RMON Group The Alarm group consists of the alarmTable, which periodically compares sampled values with configured thresholds and raises an event if a threshold is crossed. This group requires the implementation of the event group, which follows this section. Cisco ONS 15454 Reference Manual, R8.5.x 16-20 78-18106-01 Chapter 16 SNMP 16.10.6 Alarm RMON Group 16.10.6.1 Alarm Table The NMS uses the alarmTable to determine and provision network performance alarmable thresholds. 16.10.6.2 Row Creation in alarmTable To create a row in the alarmTable, all OIDs in the SetRequest PDU should be type OID.0. The table has a maximum number of 256 rows. To create a SetRequest PDU for the alarmTable, the following values are required: • The alarmInterval and its desired value • The alarmVariable and its desired value • The alarmSampleType and its desired value • The alarmStartupAlarm and its desired value • The alarmOwner and its desired value • The alarmStatus with a value of createRequest (2) If the SetRequest PDU is valid, a historyControlTable row is created. If the row already exists, or if the SetRequest PDU values do not make sense or are insufficient, the SNMP agent does not create the row and returns an error code. In addition to the required values, the following restrictions must be met in the SetRequest PDU: • The alarmOwner is a string of length 32 characters. • The alarmRisingEventIndex always takes value 1. • The alarmFallingEventIndex always takes value 2. • The alarmStatus has only two values supported in SETs: createRequest (2) and invalid (4). • The AlarmVariable is of the type OID.ifIndex, where ifIndex gives the interface this alarm is created on and OID is one of the OIDs supported in Table 16-10. Table 16-10 OIDs Supported in the AlarmTable No. Column Name OID Status 1 ifInOctets {1.3.6.1.2.1.2.2.1.10} — 2 IfInUcastPkts {1.3.6.1.2.1.2.2.1.11} — 3 ifInMulticastPkts {1.3.6.1.2.1.31.1.1.1.2} Unsupported in E100/E1000 4 ifInBroadcastPkts {1.3.6.1.2.1.31.1.1.1.3} Unsupported in E100/E1000 5 ifInDiscards {1.3.6.1.2.1.2.2.1.13} Unsupported in E100/E1000 6 ifInErrors {1.3.6.1.2.1.2.2.1.14} — 7 ifOutOctets {1.3.6.1.2.1.2.2.1.16} — 8 ifOutUcastPkts {1.3.6.1.2.1.2.2.1.17} — 9 ifOutMulticastPkts {1.3.6.1.2.1.31.1.1.1.4} Unsupported in E100/E1000 10 ifOutBroadcastPkts {1.3.6.1.2.1.31.1.1.1.5} Unsupported in E100/E1000 11 ifOutDiscards {1.3.6.1.2.1.2.2.1.19} Unsupported in E100/E1000 12 Dot3StatsAlignmentErrors {1.3.6.1.2.1.10.7.2.1.2} — 13 Dot3StatsFCSErrors {1.3.6.1.2.1.10.7.2.1.3} — Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-21 Chapter 16 SNMP 16.10.6 Alarm RMON Group Table 16-10 OIDs Supported in the AlarmTable (continued) No. Column Name OID Status 14 Dot3StatsSingleCollisionFrames {1.3.6.1.2.1.10.7.2.1.4} — 15 Dot3StatsMultipleCollisionFrames {1.3.6.1.2.1.10.7.2.1.5} — 16 Dot3StatsDeferredTransmissions {1.3.6.1.2.1.10.7.2.1.7} — 17 Dot3StatsLateCollisions {1.3.6.1.2.1.10.7.2.1.8} — 18 Dot3StatsExcessiveCollisions {13.6.1.2.1.10.7.2.1.9} — 19 Dot3StatsFrameTooLong {1.3.6.1.2.1.10.7.2.1.13} — 20 Dot3StatsCarrierSenseErrors {1.3.6.1.2.1.10.7.2.1.11} Unsupported in E100/E1000 21 Dot3StatsSQETestErrors {1.3.6.1.2.1.10.7.2.1.6} Unsupported in E100/E1000 22 etherStatsUndersizePkts {1.3.6.1.2.1.16.1.1.1.9} — 23 etherStatsFragments {1.3.6.1.2.1.16.1.1.1.11} — 24 etherStatsPkts64Octets {1.3.6.1.2.1.16.1.1.1.14} — 25 etherStatsPkts65to127Octets {1.3.6.1.2.1.16.1.1.1.15} — 26 etherStatsPkts128to255Octets {1.3.6.1.2.1.16.1.1.1.16} — 27 etherStatsPkts256to511Octets {1.3.6.1.2.1.16.1.1.1.17} — 28 etherStatsPkts512to1023Octets {1.3.6.1.2.1.16.1.1.1.18} — 29 etherStatsPkts1024to1518Octets {1.3.6.1.2.1.16.1.1.1.19} — 30 EtherStatsBroadcastPkts {1.3.6.1.2.1.16.1.1.1.6} — 31 EtherStatsMulticastPkts {1.3.6.1.2.1.16.1.1.1.7} — 32 EtherStatsOversizePkts {1.3.6.1.2.1.16.1.1.1.10} — 33 EtherStatsJabbers {1.3.6.1.2.1.16.1.1.1.12} — 34 EtherStatsOctets {1.3.6.1.2.1.16.1.1.1.4} — 35 EtherStatsCollisions {1.3.6.1.2.1.16.1.1.1.13} — 36 EtherStatsCollisions {1.3.6.1.2.1.16.1.1.1.8} — 37 EtherStatsDropEvents {1.3.6.1.2.1.16.1.1.1.3} Unsupported in E100/E1000 and G1000 16.10.6.3 Get Requests and GetNext Requests These PDUs are not restricted. 16.10.6.4 Row Deletion in alarmTable To delete a row from the table, the SetRequest PDU should contain an alarmStatus value of 4 (invalid). A deleted row can be recreated. Note Entries in the alarmTable are preserved if the SNMP agent is restarted. Cisco ONS 15454 Reference Manual, R8.5.x 16-22 78-18106-01 Chapter 16 SNMP 16.10.7 Event RMON Group 16.10.7 Event RMON Group The Event group controls event generation and notification. It consists of two tables: the eventTable, which is a read-only list of events to be generated, and the logTable, which is a writable set of data describing a logged event. The ONS 15454 implements the logTable as specified in RFC 2819. 16.10.7.1 Event Table The eventTable is read-only and unprovisionable. The table contains one row for rising alarms and another for falling ones. This table has the following restrictions: • The eventType is always log-and-trap (4). • The eventCommunity value is always a zero-length string, indicating that this event causes the trap to be despatched to all provisioned destinations. • The eventOwner column value is always “monitor.” • The eventStatus column value is always valid(1). 16.10.7.2 Log Table The logTable is implemented exactly as specified in RFC 2819. The logTable is based upon data that is locally cached in a controller card. If there is a controller card protection switch, the existing logTable is cleared and a new one is started on the newly active controller card. The table contains as many rows as provided by the alarm controller. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 16-23 Chapter 16 SNMP 16.10.7 Event RMON Group Cisco ONS 15454 Reference Manual, R8.5.x 16-24 78-18106-01 A P P E N D I X A Hardware Specifications Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This appendix contains hardware and software specifications for the ONS 15454. The following sections are included: • A.1 Shelf Specifications, page A-1 • A.2 SFP, XFP, and GBIC Specifications, page A-5 • A.3 General Card Specifications, page A-7 • A.4 Common Control Card Specifications, page A-12 • A.5 Electrical Card Specifications, page A-17 • A.6 Optical Card Specifications, page A-27 • A.7 Ethernet Card Specifications, page A-48 • A.8 Storage Access Networking Card Specifications, page A-53 A.1 Shelf Specifications This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; LAN, TL1, modem, alarm, and electrical interface assembly (EIA) interface specifications; timing, power, and environmental specifications; and shelf dimensions. A.1.1 Bandwidth The ONS 15454 has the following bandwidth specifications: • Total bandwidth: 240 Gbps • Data plane bandwidth: 160 Gbps • SONET plane bandwidth: 80 Gbps Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-1 Appendix A Hardware Specifications A.1.2 Configurations A.1.2 Configurations The ONS 15454 can be configured as follows: • Two-fiber path protection • Path protected mesh network (PPMN) • Two-fiber bidirectional line switch ring (BLSR) • Four-fiber BLSR • Add-drop multiplexer (ADM) • Terminal mode • Regenerator mode • Hubbed rings • Multihubbed rings • Point-to-point • Linear • Linear with optical add/drop multiplexing (OADM) A.1.3 Cisco Transport Controller CTC, the ONS 15454 craft interface software, has the following specifications: • 10BaseT • TCC2/TCC2P access: RJ-45 connector • Backplane access: LAN pin field A.1.4 External LAN Interface The ONS 15454 external LAN interface has the following specifications: • 10BaseT Ethernet • Backplane access: LAN pin field A.1.5 TL1 Craft Interface The ONS 15454 TL1 craft interface has the following specifications: • Speed: 9600 bps • TCC2/TCC2P access: EIA/TIA-232 DB-9 type connector • Backplane access: CRAFT pin field A.1.6 Modem Interface The ONS 15454 modem interface has the following specifications: Cisco ONS 15454 Reference Manual, R8.5.x A-2 78-18106-01 Appendix A Hardware Specifications A.1.7 Alarm Interface • Hardware flow control • TCC2/TCC2P: EIA/TIA-232 DB-9 type connector A.1.7 Alarm Interface The ONS 15454 alarm interface has the following specifications: • Visual: Critical, Major, Minor, Remote • Audible: Critical, Major, Minor, Remote • Alarm contacts: 0.045 mm, –48 V, 50 mA • Backplane access: Alarm pin fields A.1.8 EIA Interface The ONS 15454 EIA interface has the following specifications: • SMB: AMP #415504-3 75-ohm, 4-leg connectors • BNC: Trompeter #UCBJ224 75-ohm 4 leg connector (King and ITT are also compatible) • AMP Champ: AMP#552246-1 with #552562-2 bail locks A.1.9 BITS Interface The ONS 15454 building integrated timing supply (BITS) interface has the following specifications: • 2 DS-1 BITS inputs • 2 derived DS-1 outputs • Backplane access: BITS pin field A.1.10 System Timing The ONS 15454 has the following system timing specifications: • Stratum 3 per Telcordia GR-253-CORE • Free running accuracy: +/–4.6 ppm • Holdover stability: 3.7 x10–7 per day, including temperature (< 255 slips in first 24 hours) • Reference: External BITS, line, internal A.1.11 System Power The ONS 15454 ANSI has the following power specifications: • Nominal Input Voltage: –48 VDC • Power consumption: Configuration dependent; 55 W (fan tray only) • Power requirements: Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-3 Appendix A Hardware Specifications A.1.12 Fan Tray – Nominal: –48 VDC – Input Voltage Range: –40.5 to –57.0 VDC • Power terminals: #6 Lug • ANSI shelf fusing: 100–A fuse panel (minimum 30 A fuse per shelf) HD shelf fusing: 100–A fuse panel (minimum 30 A fuse per shelf) The ONS 15454 ETSI has the following power specifications: • Nominal Input Voltage: –48 VDC • Power consumption: Configuration dependent; 53 W (fan tray only) • Power requirements: – Nominal: –48 VDC – Input Voltage Range: –40.5 to –57.0 VDC • Power terminals: 3WK3 Combo-D power cable connector (MIC-A/P and MIC-C/T/P faceplates) • Fusing: 100 A fuse panel; minimum 30 A fuse per shelf A.1.12 Fan Tray Table A-1 lists power requirements for the fan-tray assembly. Table A-1 Fan Tray Assembly Power Requirements Fan Tray Assembly Watts Amps BTU/Hr FTA2 53 1.21 198 FTA3 -T 129.60 2.7 442.21 15454-CC-FTA 115 2.4 393 A.1.13 System Environmental Specifications The ONS 15454 has the following environmental specifications: • Operating temperature: 0 to +55 degrees Celsius; –40 to +65 degrees Celsius with industrial temperature rated cards • Operating humidity: 5 to 95 percent, noncondensing A.1.14 Dimensions The ONS 15454 shelf assembly has the following dimensions: • Height: 18.25 in. (46.3 cm) • Width: 19 or 23 in. (48.3 cm or 58.4 cm) with mounting ears attached • Depth: 12.018 in. (30.5 cm) for standard door and 13.810 in. (35 cm) for deep door • Weight: 55 lb (24.947 kg) empty Cisco ONS 15454 Reference Manual, R8.5.x A-4 78-18106-01 Appendix A Hardware Specifications A.2 SFP, XFP, and GBIC Specifications A.2 SFP, XFP, and GBIC Specifications Table A-2 lists the specifications for the available Small Form-factor Pluggables (SFPs), 10 Gbps Pluggables (XFPs) and GBICs. In the table, the following acronyms are used: • ESCON = Enterprise System Connection • FICON = fiber connectivity • GE = Gigabit Ethernet • FE = Fast Ethernet • E = Ethernet (10 Mbps) • FC = Fibre Channel • HDTV = high definition television • CWDM = coarse wavelength division multiplexing Table A-2 SFP, XFP, and GBIC Specifications SFP/XFP Product ID Interface Transmitter Output Receiver Input Power Power Min/Max (dBm) Min/Max (dBm) 15454-SFP-LC-SX/ 15454E-SFP-LC-SX GE –9.5 to –4 –17 to 0 15454-SFP-LC-LX/ 15454E-SFP-LC-LX GE –9.5 to –3 –19 to –3 15454-SFP3-1-IR= OC-3 –15 to –8 –23 to –8 15454E-SFP-L.1.1= STM-1 –15 to –8 –34 to –10 15454-SFP12-4-IR= OC-12, D1 Video –15 to –8 –28 to –7 15454E-SFP-L.4.1= STM-4, D1 Video –15 to –8 –28 to –8 15454-SFP-OC48-IR= OC-48, DV6000 (C-Cor) –5 to 0 –18 to 0 ONS-SE-2G-S1= OC-48, STM-16 –10 to –3 –18 to –3 15454E-SFP-L.16.1= STM-16, DV6000 (C-Cor) –5 to 0 –18 to 0 15454-SFP-200/ 15454E-SFP-200 ESCON –8 to –4 –28 to –3 15454-SFP-GEFC-SX=/ FC (1 and 2 Gbps), 15454E-SFP-GEFC-S= FICON, GE –10 to –3.5 –17 to 0 (1 FC and 1GE) 15454-SFP-GE+-LX=/ 15454E-SFP-GE+-LX= FC (1 and 2 Gbps), FICON, GE, HDTV –9.5 to –3 –20 to –3 (1 FC, 1GE, and 2 FC) ONS-SE-200-MM= ESCON –20.5 to –15 –14 to –29 1 ONS-SE-G2F-SX= Fibre Channel (1 and 2 Gbps), GE –9.5 to 0 (GE) –10 to –3.5 (1G and 2G FC/FICON) –17 to 02 (GE) –22 (1G FC/FICON) –20 (2G FC/FICON) ONS-SE-G2F-LX= Fibre Channel (1 and 2 Gbps), FICON, GE, HDTV –9.5 to –3 (GE) –19 to –33 (GE) –10 to –3.5 (1FC, 2FC, –22 (1G FC/FICON) and FICON) –21 (2G FC/FICON) –15 to 0 (2 FC) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-5 Appendix A Hardware Specifications A.2 SFP, XFP, and GBIC Specifications Table A-2 SFP, XFP, and GBIC Specifications (continued) SFP/XFP Product ID Interface Transmitter Output Receiver Input Power Power Min/Max (dBm) Min/Max (dBm) ONS-SC-GE-SX= GE –9.5 to 0 –17 to 02 ONS-SC-GE-LX= GE –9.5 to –3 –19 to –33 ONS-SI-2G-S1 OC-48 SR –10 to –3 –18 to –3 ONS-SI-2G-I1 OC-48 IR1 –5 to 0 –18 to 0 ONS-SI-2G-L1 OC-48 LR1 –2 to +3 –27 to –9 OC-48 LR2 –2 to +3 –28 to –9 OC-48 DWDM 0 to +4 –28 to –9 ONS-SI-622-I1 OC-3/OC-12 IR1 Dual rate –15 to –8 –28 to –8 ONS-SI-622-L1 OC-12 LR1 –3 to +2 –28 to –8 ONS-SI-622-L2 OC-12 LR2 –3 to +2 –28 to –8 ONS-SE-622-1470 through ONS-SE-622-1610 OC-12/STM-4 CWDM 0 to +5 –28 to –7 ONS-SI-155-I1 OC-3 IR1 –15 to –8 –28 to –8 ONS-SI-155-L1 OC-3 LR1 –5 to 0 –34 to –10 ONS-SI-155-L2 OC-3 LR2 –5 to 0 –34 to –10 ONS_SE-155-1470 through ONS-SE-155-1610 OC-3 CWDM 0 to +5 –34 to –7 ONS-XC-10G-S1 OC-192 SR1 –6 to –1 –11 to –1 ONS-XC-10G-I2 OC-192 IR2 –1 to +2 –14 to +2 ONS-XC-10G-L2 OC-192 LR2 0 to +4 –24 to –7 ONS-XC-10G-30.3= through ONS-XC-10G-61.4= OC-192/STM64/10GE –1 to +3 –27 to –7 ONS-SE-100-FX FE –20 to –14 –30 to –14 ONS-SE-100-LX10 FE –15 to –8 –25 to –8 15454-GBIC-SX FC, GE –9.5 to –3.5 –19 to –3 15454E-GBIC-SX GE, FC — 15454-GBIC-LX/LH GE, FC –9 to –3 –19 to –3 15454E-GBIC-LX/LH GE, FC –9 to –3 –19 to –3 ONS-GX-2FC-MMI FC –9.5 to –5 –20.5/–15 max ONS-GX-2FC-SML FC –9 to –3 –18 to –3 ONS-SI-155-SR-MM= OC-3, STM-1 -20 to -14 -30 to -14 ONS-SI-2G-L2 ONS-SC-2G-28.7 through ONS-SC-2G-60.6 4 — Cisco ONS 15454 Reference Manual, R8.5.x A-6 78-18106-01 Appendix A Hardware Specifications A.3 General Card Specifications Table A-2 SFP, XFP, and GBIC Specifications (continued) SFP/XFP Product ID Interface ONS-SI-622-SR-MM= OC-12, STM-4 Transmitter Output Receiver Input Power Power Min/Max (dBm) Min/Max (dBm) -20 to -14 (50 micrometer) -26 to -14 -24 to -14 (62.5 micrometer) ONS-SC-Z3-1470= through ONS-SC-Z3-1610= OC48/STM16/GE 0 to +5 –7 (min) ONS-SE-Z1= OC-3/STM1 OC-12/STM-4 OC-48/STM-16 Fibre Channel (1 and 2 Gbps) GE –5 to 0 –10 to –23 (OC-3) 0 to –23 (OC-12) –18 to 0 (OC-48) 0 to –21 (Fibre Channel) 0 to –22 (GE) ONS-SI-2G-S1 OC-48/STM-16 –10 to –3 –3 min ONS-SE-155-1470 through ONS-SE-155-1610 OC-3/STM-1 0 to +5 –7 to 0 ONS-SI-GE-SX GE -9.5 to -3 0 to –17 ONS-SI-GE-LX GE -9.5 to +3 -3 to -17 ONS-SI-GE-ZX GE +5 to 0 0 to –23 ONS-SI-100-FX FE — — ONS-SI-100-LX10 FE — — ONS-SE-ZE-EL E, FE, or GE — — ONS-SE-100-BX10U FE -14 to -8 -8 to -28.2 ONS-SE-100-BX10D FE -14 to -8 -8 to -28.2 1. Based on any valid 8B/10B code pattern measured at, or extrapolated to, 10E-15 BER measured at center of eye 2. Minimum Stressed Sensitivity (10-12): -12.5(62.5um) and -13.5(50um) dBm 3. Minimum Stressed Sensitivity (10 –12): -14.4 dBm 4. ONS-SC-2G-28.7, ONS-SC-2G-33.4, ONS-SC-2G-41.3, ONS-SC-2G-49.3, and ONS-SC-2G-57.3 are supported from Release 8.5 and later. A.3 General Card Specifications This section provides power specifications and temperature ranges for all ONS 15454 cards. A.3.1 Power Table A-3 provides power consumption information for the ONS 15454 cards. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-7 Appendix A Hardware Specifications A.3.1 Power Table A-3 Individual Card Power Requirements Card Type Card Name Watts Amperes BTU/Hr. Control Cards TCC2 19.20 0.4 66.8 TCC2P 27.00 0.56 92.2 XCVT 34.40 0.72 117.46 XC10G 48 1 163.68 XC-VXC-10G 67 1.4 228.62 AIC-I 4.8 0.1 15.3 AEP 3 (from +5 VDC from AIC-I) 10.2 FTA3 Fan Tray –48 VDC 129.60 2.7 442.21 FTA4 Fan Tray –48 VDC 115 2.4 393 EC1-12 36.60 0.76 124.97 DS1-14 12.60 0.26 43.02 DS1N-14 12.60 0.26 43.02 DS1/E1-56 36.00 0.76 124.97 DS3-12 38.20 0.79 130.43 DS3/EC1-48 30 0.58 95.6 DS3N-12 38.20 0.79 130.43 DS3i-N-12 30 0.63 102.4 DS3-12E 26.80 0.56 91.51 DS3N-12E 26.80 0.56 91.51 DS3XM-12 Transmux 34 0.71 116.1 DS3XM-6 Transmux 20 0.42 68 Electrical Cards Cisco ONS 15454 Reference Manual, R8.5.x A-8 78-18106-01 Appendix A Hardware Specifications A.3.1 Power Table A-3 Individual Card Power Requirements (continued) Card Type Card Name Watts Amperes BTU/Hr. Optical Cards OC3 IR 4 19.20 0.40 65.56 OC3 IR 4/STM1 SH 1310 19.20 0.40 65.56 OC3 IR 4/STM1SH 1310-8 26.00 0.48 78.5 OC12 IR 1310 10.90 0.23 37.22 OC12 LR 1310 9.28 0.2 31.68 OC12 LR 1550 9.28 0.2 31.68 OC12 LR/STM4 LH 1310 9.00 0.2 31.68 OC12 LR/STM4 LH 1550 9.28 0.2 31.68 OC12 IR/STM4 SH 1310-4 35.60 0.74 121.6 OC48 IR 1310 32.20 0.67 109.94 OC48 LR 1550 26.80 0.56 91.50 OC48 IR/STM16 SH AS 1310 37.20 0.77 127.01 OC48 LR/STM16 LH AS 1550 37.20 0.77 127.01 OC48 ELR/STM16 EH 100 GHz 31.20 0.65 106.53 OC48 ELR 200 GHz 31.20 0.65 106.53 OC192 SR/STM64 IO H 1310 41.80 0.90 132.00 OC192 IR/STM64 SH 1550 48.00 1.00 163.68 OC192 LR/STM64 LH 1550 41.80 0.90 132.00 OC192 LR/STM64 LH 15xx.xx 62.40 1.30 214.00 15454_MRC-12 38 0.79 129.66 MRC-2.5G-4 38 0.79 129.66 OC192SR1/STM64IO Short Reach and OC-192/STM64 Any Reach1 40 0.83 136.49 E100T-12 65 1.35 221.93 E100T-G 65 1.35 221.93 E1000-2 53.50 1.11 182.67 E1000-2-G 53.50 1.11 182.67 G1K-4 63.00 (including GBICs2) 1.31 215.11 ML100T-12 53 1.10 181.00 ML1000-2 49 (including SFPs) 1.02 167.30 ML100X-8 65 1.35 221.93 ML-MR-10 100 N/A N/A CE-100T-8 53.14 1.10 181.30 CE-1000-4 60 1.25 204.80 CE-MR-10 95 1.35 221.93 Ethernet Cards Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-9 Appendix A Hardware Specifications A.3.2 Temperature Table A-3 Individual Card Power Requirements (continued) Card Type Card Name Watts Amperes BTU/Hr. Storage Access Networking FC_MR-4 60 1.25 212.00 1. These cards are designated as OC192-XFP in CTC. 2. GBICs = Gigabit Interface Converters A.3.2 Temperature Table A-4 provides temperature ranges and product names for ONS 15454 cards. Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant. Table A-4 Card Temperature Ranges and Product Names I-Temp Product Name (–40 to 149 degrees Fahrenheit, –40 to +65 degrees Celsius) Card Type Card Name C-Temp Product Name (32 to 131 degrees Fahrenheit, 0 to +55 degrees Celsius) Control Cards TCC2 — 15454-TCC2 TCC2P — 15454-TCC2P XCVT 15454-XC-VT 15454-XC-VT-T XC10G 15454-XC-10G — XC-VXC-10G — 15454-XC-VXC-10G-T AIC-I — 15454-AIC-I AEP — 15454-AEP EC1-12 15454-EC1-12 15454-EC1-12-T DS1-14 15454-DS1-14 15454-DS1-14-T DS1N-14 15454-DS1N-14 15454-DS1N-14-T DS1/E1-56 — 15454-DS1E1-56 DS3-12 15454-DS3-12 15454-DS3-12-T DS3/EC1-48 — 15454-DS3_EC1-48 DS3N-12 15454-DS3N-12 15454-DS3N-12-T DS3i-N-12 15454-DS3i-N-12 — DS3-12E — 15454-DS3-12E-T DS3N-12E — 15454-DS3N-12E-T DS3XM-12 (Transmux) — 15454-DS3XM-12 DS3XM-6 (Transmux) 15454-DS3XM-6 15454-DS3XM-6-T Electrical Cisco ONS 15454 Reference Manual, R8.5.x A-10 78-18106-01 Appendix A Hardware Specifications A.3.2 Temperature Table A-4 Card Temperature Ranges and Product Names (continued) Card Type Card Name C-Temp Product Name (32 to 131 degrees Fahrenheit, 0 to +55 degrees Celsius) I-Temp Product Name (–40 to 149 degrees Fahrenheit, –40 to +65 degrees Celsius) Optical OC3 IR 4/STM1 SH 1310 15454-OC34IR1310 15454-OC34I13-T OC3 IR/STM1 SH 1310-8 15454-OC3I8-1310 — OC12 IR/STM4 SH 1310 15454-OC121IR1310 15454-OC121I13-T OC12 LR/STM4 LH 1310 15454-OC121LR1310 15454-OC121L13-T OC12 LR/STM4 LH 1550 15454-OC121LR1550 15454-OC121L15-T OC12 IR/STM4 SH 1310-4 15454-OC12I4-1310 — OC48 IR 1310 15454-OC481IR1310 — OC48 LR 1550 15454-OC481LR1550 — OC48 IR/STM16 SH AS 1310 15454-OC481IR1310A — OC48 LR/STM16 LH AS 1550 15454-OC481LR1550A — OC48 ELR/STM16 EH 100 GHz 15454-OC48E-1-xx.xx (all wavelengths) — OC48 ELR/STM16 EH 200 GHz 15454-OC48E-xx.xx (all wavelengths) — OC 192 SR/STM64 IO 1310 15454-OC192IO1310 — OC192 IR/STM64 SH 1550 15454-OC192IR1550 — OC192 LR/STM64 LH 1550 15454-OC192LR1550 — OC192 LR/STM64 LH ITU 15xx.xx 15454-OC192LR15xx — 15454_MRC-12 — 15454-MRC-12-T MRC-2.5G-4 — 15454-MRC-I-4 OC-192/STM-64 SR1 Short Reach1 15454_OC-192/STM-64 — SR1 Short Reach OC-192/STM-64 Any Reach1 15454_OC-192/STM-64 — Any Reach Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-11 Appendix A Hardware Specifications A.4 Common Control Card Specifications Table A-4 Card Temperature Ranges and Product Names (continued) Card Type Card Name C-Temp Product Name (32 to 131 degrees Fahrenheit, 0 to +55 degrees Celsius) Ethernet E100T-12 15454-E100T — E100T-G 15454-E100T-G — E1000-2 15454-E1000-2 — E1000-2-G 15454-E1000-2-G — G1K-4 15454-G1K-4 — ML100T-12 15454-ML100T-12 — ML1000-2 15454-ML1000-2 — ML100X-8 — 15454-ML100X-8 ML-MR-10 — 15454-ML-MR-10 CE-100T-8 15454-CE100T-8 — CE-1000-4 15454-CE1000-4 — CE-MR-10 15454-CE-MR-10 — FC_MR-4 15454-FC_MR-4 — Storage Access Networking I-Temp Product Name (–40 to 149 degrees Fahrenheit, –40 to +65 degrees Celsius) 1. Designated as OC192-XFP in CTC. A.4 Common Control Card Specifications This section provides specifications for the TCC2, TCC2P, XCVT, XC10G, XC-VXC-10G, and AIC-I cards. For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document. A.4.1 TCC2 Card Specifications The TCC2 card has the following specifications: • CTC software – Interface: EIA/TIA-232 (local craft access, on TCC2 faceplate) – Interface: 10BaseT LAN (on TCC2 faceplate) – Interface: 10BaseT LAN (through the backplane) • Synchronization – Stratum 3, per Telcordia GR-253-CORE – Free running access: Accuracy +/– 4.6 ppm – Holdover stability: 3.7 * 10 exp – 7 per day including temperature (< 255 slips in first 24 hours) Cisco ONS 15454 Reference Manual, R8.5.x A-12 78-18106-01 Appendix A Hardware Specifications A.4.2 TCC2P Card Specifications – Reference: External BITS, line, internal • Supply voltage monitoring – Both supply voltage inputs are monitored. – Normal operation: –40.5 to –56.7 V – Undervoltage: Major alarm – Overvoltage: Major alarm • Environmental – Operating temperature: –40 to +149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 26.00 W, 0.54 A at –48 V, 88.8 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 1.5 lb (0.7 kg) A.4.2 TCC2P Card Specifications The TCC2P card has the following specifications: • CTC software – Interface: EIA/TIA-232 (local craft access, on TCC2P faceplate) – Interface: 10BaseT LAN (on TCC2P faceplate) – Interface: 10BaseT LAN (via backplane) • Synchronization – Stratum 3, per Telcordia GR-253-CORE – Free running access: Accuracy +/– 4.6 ppm – Holdover stability: 3.7 * 10 exp – 7 per day including temperature (< 255 slips in first 24 hours) – Reference: External BITS, line, internal • Supply voltage monitoring – Both supply voltage inputs are monitored. – Normal operation: –40.5 to –56.7 V (in –48 VDC systems) – Undervoltage: Major alarm – Overvoltage: Major alarm • Environmental – Operating temperature: –40 to +149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 27.00 W, 0.56 A at –48 V, 92.2 BTU/hr Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-13 Appendix A Hardware Specifications A.4.3 XCVT Card Specifications • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 1.5 lb (0.7 kg) A.4.3 XCVT Card Specifications The XCVT card has the following specifications: • Environmental – Operating temperature: C-Temp (15454-XC-VT): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) I-Temp (15454-XC-VT-T): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 34.40 W, 0.72 A, 117.46 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 1.9 lb (0.8 kg) A.4.4 XC10G Card Specifications The XC10G card has the following specifications: • Environmental – Operating temperature: C-Temp (15454-XC-10G): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) – Operating humidity: 5 to 85 percent, noncondensing – Power consumption: 48 W, 1.00 A, 163.68 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 1.5 lb (0.6 kg) Cisco ONS 15454 Reference Manual, R8.5.x A-14 78-18106-01 Appendix A Hardware Specifications A.4.5 XC-VXC-10G Card Specifications A.4.5 XC-VXC-10G Card Specifications The XC-VXC-10G card has the following specifications: • Environmental – Operating temperature: I-Temp (15454-XC-VXC-10G-T): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 85 percent, noncondensing – Power consumption: 67 W, 1.4 A, 228.62 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 1.5 lb (0.6 kg) A.4.6 AIC-I Card Specifications The AIC-I card has the following specifications: • Alarm inputs – Number of inputs: 12 without alarm extension panel (AEP), 32 with AEP – Opto coupler isolated – Label is customer provisionable. – Severity is customer provisionable. – Common 32 V output for all alarm inputs – Each input limited to 2 mA – Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP • Alarm outputs – Number of outputs: 4 (user configurable as inputs) without AEP, 16 with AEP – Switched by opto MOS (metal oxide semiconductor) – Triggered by definable alarm condition – Maximum allowed open circuit voltage: 60 VDC – Maximum allowed closed circuit current: 100 mA – Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP • Express orderwire/Local orderwire (EOW/LOW) – ITU-T G.711, ITU-T G.712, Telcordia GR-253-CORE – A-law, mu-law Note Due to the nature of mixed coding, in a mixed-mode configuration (A-law/mu-law) the orderwire is not ITU-T G.712 compliant. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-15 Appendix A Hardware Specifications A.4.7 AEP Specifications – Orderwire party line – Dual tone multifrequency (DTMF) signaling • User data channel (UDC) – Bit rate: 64 kbps, bidirectional – ITU-T G.703 – Input/output impedance: 120 ohm – Termination: RJ-11 connectors • Data communications channel (DCC) – Bit rate: 576 kbps – EIA/TIA-485/V11 – Input/output impedance: 120 ohm – Termination: RJ-45 connectors • ACC connection for additional alarm interfaces – Connection to AEP • Power monitoring alarming states: – Power failure (0 to –38 VDC) – Undervoltage (–38 to –40.5 VDC) – Overvoltage (beyond –56.7 VDC) • Environmental – Operating temperature: –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption (including AEP, if used): 8.00 W, 0.17 A, 27.3 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 1.8 lb (0.82 kg) A.4.7 AEP Specifications The AEP has the following specifications: • Alarm inputs – Number of inputs: 32 – Optocoupler isolated – Label customer provisionable – Severity customer provisionable – Common 32 V output for all alarm inputs – Each input limited to 2 mA Cisco ONS 15454 Reference Manual, R8.5.x A-16 78-18106-01 Appendix A Hardware Specifications A.5 Electrical Card Specifications – Termination: 50-pin AMP champ connector • Alarm outputs – Number of outputs: 16 – Switched by opto MOS – Triggered by definable alarm condition – Maximum allowed open circuit voltage: 60 VDC – Maximum allowed closed circuit current: 100 mA – Termination: 50-pin AMP champ connector • Environmental – Overvoltage protection: as in ITU-T G.703 Annex B – Operating temperature: –40 to +65 degrees Celsius – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 3.00 W max., from +5 VDC from AIC-I, 10.2 BTU/hr max. • Dimensions of AEP board – Height: 0.79 in. (20 mm) – Width: 13.0 in. (330 mm) – Depth: 3.5 in. (89 mm) – Weight: 0.4 lb (0.18 kg) A.5 Electrical Card Specifications This section provides specifications for the EC1-12, DS1-14, DS1N-14, DS1/E1-56, DS3/EC1-48, DS3-12, DS3N-12, DS3i-N-12, DS3-12E, DS3N-12E, DS3XM-6, DS3XM-12, and filler cards. For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document. A.5.1 EC1-12 Card Specifications The EC1-12 card has the following specifications: • Input – Bit rate: 51.84 Mbps +/– 20 ppm – Frame format: SONET – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/– 5 percent – Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179 – AIS: TR-TSY-000191 compliant • Output Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-17 Appendix A Hardware Specifications A.5.2 DS1-14 and DS1N-14 Card Specifications – Bit rate: 51.84 Mbps +/– 20 ppm – Frame format: SONET – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179 – AIS: TR-TSY-000191 compliant – Power level: –1.8 +/– 5.7 dBm – Pulse shape: ANSI T1.102-1988 Figure 8 – Pulse amplitude: 0.36 to 0.85 V peak – Loopback modes: Terminal and facility – Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters) • Electrical interface: BNC or SMB connectors • Operating temperature – C-Temp (15454-EC1-12): 0 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) – I-Temp (15454-EC1-12-T): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant. • Operating humidity: 5 to 95 percent, noncondensing • Power consumption: 36.60 W, 0.76 A, 124.97 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 2.0 lb (0.9 kg) A.5.2 DS1-14 and DS1N-14 Card Specifications The DS1-14 and DS1N-14 cards have the following specifications: • Input – Bit rate: 1.544 Mbps +/– 32 ppm – Frame format: Off, SF (D4), ESF – Line code: AMI, B8ZS – Termination: Wire-wrap, AMP Champ – Input impedance: 100 ohms – Cable loss: Max 655 feet ABAM #22 AWG – AIS: TR-TSY-000191 compliant Cisco ONS 15454 Reference Manual, R8.5.x A-18 78-18106-01 Appendix A Hardware Specifications A.5.3 DS1/E1-56 Card Specifications • Output – Bit rate: 1.544 Mbps +/– 32 ppm – Frame format: Off, SF (D4), ESF – Line code: AMI, B8ZS – Termination: Wire-wrap, AMP Champ – Input impedance: 100 ohms – Cable loss: Max 655 feet ABAM #22 AWG – AIS: TR-TSY-000191 compliant – Power level: 12.5 to 17.9 dBm centered at 772 KHz, –16.4 to –11.1 dBm centered at 1544 KHz – Pulse shape: Telcordia GR-499-CORE Figure 9-5 – Pulse amplitude: 2.4 to 3.6 V peak – Loopback modes: Terminal and facility • Electrical interface: BNC or SMB connectors • Surge protection: Telcordia GR-1089 • Operating temperature – C-Temp (15454-DS1-14 and 15454-DS1N-14): 0 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) – I-Temp (15454-DS1-14-T and 15454-DS1N-14-T): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant. • Operating humidity: 5 to 95 percent, noncondensing • Power consumption: 12.60 W, 0.26 A, 43.02 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 1.8 lb (0.8 kg) A.5.3 DS1/E1-56 Card Specifications The DS1/E1-56 card has the following specifications: • Input – Bit rate: 1.544 Mbps ± 32 ppm (DS-1); 2.048 Mbps ±50ppm (E1) – Frame format: Off, SF (D4), ESF (DS-1); E1 multiframe, E1 CRC multiframe, and unframed (ITU) (E1) – Line code: AMI, B8ZS (DS-1); HDB3 (E1) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-19 Appendix A Hardware Specifications A.5.4 DS3/EC1-48 Card Specifications – Termination: Balanced, twisted pair, #22/24 AWG – Input impedance: 100 ohms +/– 5 percent (DS1); 120 ohms =/–5% (E1) – Cable loss: Max 655 feet ABAM #22/24 AWG (DS1); Compliant per ITU-T G.703 (E1) – AIS: TR-TSY-000191 compliant • Output – Bit rate: 1.544 Mbps ± 32 ppm (DS-1); 2.048 Mbps ±50ppm (E1) – Frame format: Off, SF (D4), ESF (DS-1); E1 multiframe, E1 CRC multiframe, and unframed (ITU) (E1) – Line code: AMI, B8ZS (DS-1); HDB3 (E1) – Termination: Balanced, twisted pair, #22/24 AWG – Input impedance: 100 ohms +/– 5 percent (DS1); 120 ohms =/–5% (E1) – Cable loss: Max 655 feet ABAM #22/24 AWG (DS1); Compliant per ITU-T G.703 (E1) – AIS: TR-TSY-000191 compliant – Power level: 12.6 to 17.9 dBm centered at 772 KHz – Pulse shape: Telcordia GR-499-CORE Figure 9-5 (DS-1); ITU-T G.703, Figure 15 (E1) – Pulse amplitude: 2.4 to 3.6 V peak (DS-1); 2.7 to 3.3 V peak (E1) – Loopback modes: Terminal and facility • Electrical interface: SCSI (UBIC) connectors. UBIC-H: DS-1 and E1; UBIC-V: DS-1 only. • Surge protection: Telcordia GR-1089 • Operating temperature – I-Temp (15454-DS1E1-56):–40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant. • Operating humidity: 5 to 95 percent, noncondensing • Power consumption: 36.00 W, 0.76 A, 124.97 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 2.0 lb (0.9 kg) A.5.4 DS3/EC1-48 Card Specifications The DS3/EC1-48 card has the following specifications: • Input – Bit rate: 44.736 Mbps +/– 20 ppm – Frame format: DS-3 ANSI T1.107-1988 Cisco ONS 15454 Reference Manual, R8.5.x A-20 78-18106-01 Appendix A Hardware Specifications A.5.5 DS3-12 and DS3N-12 Card Specifications – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 450 feet with 734A or 728A, Max 79 feet with RG-179 – AIS: TR-TSY-000191 compliant • Output – Bit rate: 44.736 Mbps +/– 20 ppm – Frame format: DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 900 feet with 734A or 728A cable, Max 79 feet with RG-179 – AIS: TR-TSY-000191 compliant – Power level: –1.8 to +5.7 dBm – Pulse shape: ANSI T1.102-1988 Figure 8 – Pulse amplitude: 0.36 to 0.85 V peak – Loopback modes: Terminal and facility – Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters) • Electrical interface: BNC or SMB connectors • Surge protection: Telcordia GR-1089 • Operating temperature: – I-Temp (15454-DS3_EC1-48): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant. • Operating humidity: 5 to 95 percent, noncondensing • Power consumption: 28W, 0.58 A at –48 V, 95.6 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight: 1.7 lb (0.7 kg) A.5.5 DS3-12 and DS3N-12 Card Specifications The DS3-12 and DS3N-12 cards have the following specifications: • Input – Bit rate: 44.736 Mbps +/– 20 ppm Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-21 Appendix A Hardware Specifications A.5.5 DS3-12 and DS3N-12 Card Specifications – Frame format: DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179 – AIS: TR-TSY-000191 compliant • Output – Bit rate: 44.736 Mbps +/– 20 ppm – Frame format: DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179 – AIS: TR-TSY-000191 compliant – Power level: –1.8 to +5.7 dBm – Pulse shape: ANSI T1.102-1988 Figure 8 – Pulse amplitude: 0.36 to 0.85 V peak-to-peak – Loopback modes: Terminal and facility – Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters) • Electrical interface: BNC or SMB connectors • Surge protection: Telcordia GR-1089 • Operating temperature C-Temp (15454-DS3-12 and 15454-DS3N-12): 0 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) – I-Temp (15454-DS3-12-T and 15454-DS3N-12-T): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant. • Operating humidity: 5 to 95 percent, noncondensing • Power consumption: 38.20 W, 0.79 A, 130.43 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – DS3-12 card weight: 1.7 lb (0.7 kg) – DS3N-12 card weight: 1.8 lb (0.8 kg) Cisco ONS 15454 Reference Manual, R8.5.x A-22 78-18106-01 Appendix A Hardware Specifications A.5.6 DS3i-N-12 Card Specifications A.5.6 DS3i-N-12 Card Specifications The DS3i-N-12 card has the following specifications: • Input – Bit rate: 44.736 Mbps +/–20 ppm – Frame format: ITU-T G.704, ITU-T G.752/DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/– 5 percent – Cable loss: Maximum 137 m (450 ft): 734A, RG59, 728A Maximum 24 m (79 ft): RG179 – AIS: ITU-T G.704 compliant • Output – Bit rate: 44.736 Mbps +/– 20 ppm – Frame format: ITU-T G.704, ITU-T G.752/DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Output impedance: 75 ohms +/–5 percent – AIS: ITU-T G.704 compliant – Power level: –1.8 to +5.7 dBm Note The power level is for a signal of all ones and is measured at a center frequency of 22.368 MHz (3 +/–1 kHz) bandwidth.) – Pulse shape: ITU-T G.703, Figure 14/ANSI T1.102-1988, Figure 8 – Pulse amplitude: 0.36 to 0.85 V peak-to-peak – Loopback modes: Terminal and facility – Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters) • Electrical interface connectors: SMB, BNC • Environmental – Overvoltage protection: As in ITU-T G.703 Annex B – Operating temperature: +23 to +113 degrees Fahrenheit (–5 to +45 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 26.80 W, 0.56 A at –48 V, 91.5 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-23 Appendix A Hardware Specifications A.5.7 DS3-12E and DS3N-12E Card Specifications – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 1.9 lb (0.8 kg) A.5.7 DS3-12E and DS3N-12E Card Specifications The DS3-12E and DS3N-12E cards have the following specifications: • Input – Bit rate: 44.736 Mbps +/– 20 ppm – Frame format: DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179 – AIS: TR-TSY-000191 compliant • Output – Bit rate: 44.736 Mbps +/– 20 ppm – Frame format: DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179 – AIS: TR-TSY-000191 compliant – Power level: –1.8 to +5.7 dBm Note The power level is for a signal of all ones and is measured at a center frequency of 22.368 MHz (3 +/–1 kHz) bandwidth. – Pulse shape: ANSI T1.102-1988 Figure 8 – Pulse amplitude: 0.36 to 0.85 V peak-to-peak – Loopback modes: Terminal and facility – Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters) • Electrical interface: Connectors: BNC or SMB • Surge protection: Telcordia GR-1089 • Operating temperature: I-Temp (15454-DS3-12E-T and 15454-DS3N-12E-T): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) Note • The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant. Operating humidity: 5 to 95 percent, noncondensing Cisco ONS 15454 Reference Manual, R8.5.x A-24 78-18106-01 Appendix A Hardware Specifications A.5.8 DS3XM-12 Card Specifications • Power consumption: 26.80 W, 0.56 A, 91.51 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235.0 mm) – DS3-12E card weight: 1.8 lb (0.8 kg) – DS3N-12E card weight: 1.9 lb (0.8 kg) A.5.8 DS3XM-12 Card Specifications The DS3XM-12 card has the following specifications: • Input – Bit rate: 44.736 Mbps +/–20 ppm – Frame format: DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179 – AIS: TR-TSY-000191 compliant • Output – Bit rate: 44.736 Mbps +/– 20 ppm – Frame format: DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179 – AIS: TR-TSY-000191 compliant – Power level: –1.8 to +5.7 dBm – Pulse shape: ANSI T1.102-1988 Figure 8 – Pulse amplitude: 0.36 to 0.85 V peak-to-peak – Loopback modes: Terminal and facility – Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters) • Interface: BNC, SMB, UBIC and MiniBNC connectors • Surge protection: Telcordia GR-1089 • Operating temperature: – I-Temp (15454-DS3XM-12): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-25 Appendix A Hardware Specifications A.5.9 DS3XM-6 Card Specifications Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant. • Operating humidity: 5 to 95 percent, noncondensing • Power consumption: 34 W, 0.71A at –48 V, 116.1 BTU/hr • Dimensions – Height: 12.65 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.00 in. (228.6 mm) – Card weight: 1.8 lb (0.8 kg) A.5.9 DS3XM-6 Card Specifications The DS3XM-6 card has the following specifications: • Input – Bit rate: 44.736 Mbps +/–20 ppm – Frame format: DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179 – AIS: TR-TSY-000191 compliant • Output – Bit rate: 44.736 Mbps +/– 20 ppm – Frame format: DS-3 ANSI T1.107-1988 – Line code: B3ZS – Termination: Unbalanced coaxial cable – Input impedance: 75 ohms +/–5 percent – Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179 – AIS: TR-TSY-000191 compliant – Power level: –1.8 to +5.7 dBm – Pulse shape: ANSI T1.102-1988 Figure 8 – Pulse amplitude: 0.36 to 0.85 V peak-to-peak – Loopback modes: Terminal and facility – Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters) • Interface: BNC or SMB connectors • Surge protection: Telcordia GR-1089 • Operating temperature: Cisco ONS 15454 Reference Manual, R8.5.x A-26 78-18106-01 Appendix A Hardware Specifications A.5.10 FILLER Card Specifications – C-Temp (15454-DS3XM-6): 0 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) – I-Temp (15454-DS3XM-6-T): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant. • Operating humidity: 5 to 95 percent, noncondensing • Power consumption: 20 W, 0.42 A, 68 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 1.8 lb (0.8 kg) A.5.10 FILLER Card Specifications The FILLER cards have the following specifications: • Environmental – Operating temperature: C-Temp: -40 to +149 degree Fahrenheit (-40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 0.4 lb (0.19 kg) A.6 Optical Card Specifications This section provides specifications for the OC3 IR4/STM1 SH 1310 (four-port), OC3 IR/STM1 SH 1310-8 (eight-port), OC12 IR/STM4 SH 1310, OC12 LR/STM4 LH 1310, OC12 LR STM4 LH 1550, OC12 IR/STM4 SH 1310-4 (four-port), OC48 IR 1310, OC48 LR 1550, OC48 IR/STM16 SH AS 1310, OC48 LR/STM16 LH AS 1550, OC48 ELR 100 GHz, OC48 ELR 200 GHz, OC192 SR/STM64 IO 1310, OC192 IR/STM64 SH 1550, OC192 LR/STM64 LH 1550, OC192 LR/STM64 LH ITU 15xx.xx, 15454_MRC-12 (12-port), MRC-2.5G-4, OC192SR1/STM64IO Short Reach, and OC192/STM64 Any Reach cards. For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-27 Appendix A Hardware Specifications A.6.1 OC3 IR 4/STM1 SH 1310 Card Specifications A.6.1 OC3 IR 4/STM1 SH 1310 Card Specifications The OC3 IR 4/STM1 SH 1310 card has the following specifications: • Line – Bit rate: 155.52 Mbps – Code: Scrambled non-return to zero (NRZ) – Fiber: 1310-nm single-mode – Loopback modes: Terminal and facility – Connector: SC – Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957 • Transmitter – Maximum transmitter output power: –8 dBm – Minimum transmitter output power: –15 dBm – Center wavelength: 1274 to 1356 nm – Nominal wavelength: 1310 nm – Transmitter: Fabry Perot (FP) laser – Extinction Ratio: 8.2 dB – Dispersion Ratio: 96 ps/nm • Receiver – Maximum receiver level: –8 dBm at BER 1 * 10 exp – 12 – Minimum receiver level: –28 dBm at BER 1 * 10 exp – 12 – Receiver: InGaAs/InP photodetector – Link loss budget: 13 dB – Receiver input wavelength range: 1274 to 1356 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Environmental – Operating temperature: C-Temp (15454-OC34IR1310): +23 to +113 degrees Fahrenheit (–5 to +45 degrees Celsius) I-Temp (15454-OC34I13-T): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 19.20 W, 0.40 A at –48 V, 65.56 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 1.0 lb (0.4 kg) Cisco ONS 15454 Reference Manual, R8.5.x A-28 78-18106-01 Appendix A Hardware Specifications A.6.2 OC3 IR/STM1SH 1310-8 Card Specifications A.6.2 OC3 IR/STM1SH 1310-8 Card Specifications The OC3 IR/STM1SH 1310-8 card has the following specifications: • Line – Bit rate: 155.52 Mbps – Code: Scrambled NRZ – Fiber: 1310-nm single-mode – Loopback modes: Terminal and facility – Connector: LC – Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957 • Transmitter – Maximum transmitter output power: –8 dBm – Minimum transmitter output power: –15 dBm – Center wavelength: 1261 to 1360 nm – Nominal wavelength: 1310 nm – Transmitter: Fabry Perot laser – Extinction ratio: 8.2 dB – Dispersion tolerance: 96 ps/nm • Receiver – Maximum receiver level: –8 dBm at BER 1 * 10 exp – 12 – Minimum receiver level: –28 dBm at BER 1 * 10 exp – 12 – Receiver: InGaAs/InP photodetector – Link loss budget: 13 dB – Receiver input wavelength range: 1261 to 1360 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Environmental – Operating temperature: +23 to +113 degrees Fahrenheit (–5 to +45 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 23.00 W, 0.48 A at –48 V, 78.5 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 1.0 lb (0.4 kg) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-29 Appendix A Hardware Specifications A.6.3 OC12 IR/STM4 SH 1310 Card Specifications A.6.3 OC12 IR/STM4 SH 1310 Card Specifications The OC12 IR/STM4 SH 1310 card has the following specifications: • Line – Bit rate: 622.08 Mbps – Code: Scrambled NRZ – Fiber: 1310-nm single-mode – Loopback modes: Terminal and facility – Connectors: SC – Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957 • Transmitter – Maximum transmitter output power: –8 dBm – Minimum transmitter output power: –15 dBm – Center wavelength: 1274 to 1356 nm – Nominal wavelength: 1310 nm – Transmitter: Fabry Perot laser – Extinction ratio: 8.2 dB – Dispersion tolerance: 96 ps/nm • Receiver – Maximum receiver level: –8 dBm at BER 1 * 10 exp – 12 – Minimum receiver level: –28 dBm at BER 1 * 10 exp – 12 – Receiver: InGa As/InP photodetector – Link loss budget: 13 dB – Receiver input wavelength range: 1274 to 1356 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Environmental – Operating temperature: C-Temp (15454-OC121IR1310): +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) I-Temp (15454-OC121I13-T): –40 to +149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 10.90 W, 0.23 A at –48 V, 37.22 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 1.4 lb (0.6 kg) Cisco ONS 15454 Reference Manual, R8.5.x A-30 78-18106-01 Appendix A Hardware Specifications A.6.4 OC12 LR/STM4 LH 1310 Card Specifications A.6.4 OC12 LR/STM4 LH 1310 Card Specifications The OC12 LR/STM4 LH 1310 card has the following specifications: • Line – Bit rate: 622.08 Mbps – Code: Scrambled NRZ – Fiber: 1310-nm single-mode – Loopback modes: Terminal and facility – Connectors: SC – Compliance: Telcordia SONET, Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957 • Transmitter – Maximum transmitter output power: +2 dBm – Minimum transmitter output power: –3 dBm – Center wavelength: 1280 to 1335 nm – Nominal wavelength: 1310 nm – Transmitter: Distributed feedback (DFB) laser – Extinction ratio: 10 dB – Dispersion tolerance: 190 ps/nm • Receiver – Maximum receiver level: –8 dBm at BER 1 * 10 exp – 12 – Minimum receiver level: –28 dBm at BER 1 * 10 exp – 12 – Receiver: InGaAs/InP photodetector – Link loss budget: 25 dB – Receiver input wavelength range: 1280 to 1335 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Environmental – Operating temperature: C-Temp (15454-OC121LR1310): +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) I-Temp (15454-OC121L13-T): –40 to +149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 9.28 W, 0.25 A, 41 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 1.4 lb (0.6 kg) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-31 Appendix A Hardware Specifications A.6.5 OC12 LR/STM4 LH 1550 Card Specifications A.6.5 OC12 LR/STM4 LH 1550 Card Specifications The OC12 LR/STM4 LH 1550 card has the following specifications: • Line – Bit rate: 622.08 Mbps – Code: Scrambled NRZ – Fiber: 1550-nm single-mode – Loopback modes: Terminal and facility – Connectors: SC – Compliance: Telcordia SONET, Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957 • Transmitter – Maximum transmitter output power: +2 dBm – Minimum transmitter output power: –3 dBm – Center wavelength: 1480 to 1580 nm – Nominal wavelength: 1550 nm – Transmitter: DFB laser – Dispersion tolerance: 1440 ps/nm • Receiver – Maximum receiver level: –8 dBm at BER 1 * 10 exp – 12 – Minimum receiver level: –28 dBm at BER 1 * 10 exp – 12 – Receiver: InGaAs/InP photodetector – Link loss budget: 25 dB – Receiver input wavelength range: 1480 to 1580 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Environmental – Operating temperature: C-Temp (15454-OC121LR1550): +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) I-Temp (15454-OC121L15-T): –40 to +149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 9.28 W, 0.19 A, 31.68 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 1.4 lb (0.6 kg) Cisco ONS 15454 Reference Manual, R8.5.x A-32 78-18106-01 Appendix A Hardware Specifications A.6.6 OC12 IR/STM4 SH 1310-4 Specifications A.6.6 OC12 IR/STM4 SH 1310-4 Specifications The OC12 IR/STM4 SH 1310-4 card has the following specifications: • Line – Bit rate: 622.08 Mbps – Code: Scrambled NRZ – Fiber: 1310-nm single-mode – Loopback modes: Terminal and facility – Connector: SC – Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957 • Transmitter – Maximum transmitter output power: –8 dBm – Minimum transmitter output power: –15 dBm – Center wavelength: 1274 to 1356 nm – Nominal wavelength: 1310 nm – Transmitter: Fabry Perot laser – Extinction ratio: 10 dB – Dispersion tolerance: 190 ps/nm • Receiver – Maximum receiver level: –8 dBm – Minimum receiver level: –30 dBm – Receiver: InGaAs/InP photodetector – Link loss budget: 15 dB – Receiver input wavelength range: 1274 to 1356 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Operating temperature – C-Temp: +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) • Operating humidity – 5 to 95 percent, noncondensing • Power consumption – 28 W, 0.58 A, 100 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 1.0 lb (0.4 kg) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-33 Appendix A Hardware Specifications A.6.7 OC48 IR 1310 Card Specifications Note Minimum transmit power, minimum receive power, and link loss budget might exceed standard specifications. A.6.7 OC48 IR 1310 Card Specifications The OC48 IR 1310 card has the following specifications: • Line – Bit rate: 2.49 Gbps – Code: Scrambled NRZ – Fiber: 1310-nm single-mode – Loopback modes: Terminal and facility – Connectors: SC – Compliance: Telcordia GR-253-CORE • Transmitter – Maximum transmitter output power: 0 dBm – Minimum transmitter output power: –5 dBm – Center wavelength: 1280 to 1350 nm – Nominal wavelength: 1310 nm – Transmitter: Uncooled direct modulated DFB • Receiver – Maximum receiver level: 0 dBm – Minimum receiver level: –18 dBm – Receiver: InGaAs InP photodetector – Link loss budget: 13 dB minimum – Receiver input wavelength range: 1280 to 1350 nm • Environmental – Operating temperature: C-Temp (15454-OC481IR1310): +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 32.20 W, 0.67 A, 109.94 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 1.8 lb (0.8 kg) Cisco ONS 15454 Reference Manual, R8.5.x A-34 78-18106-01 Appendix A Hardware Specifications A.6.8 OC48 LR 1550 Card Specifications A.6.8 OC48 LR 1550 Card Specifications The OC48 LR 1550 card has the following specifications: • Line – Bit rate: 2.49 Gbps – Code: Scrambled NRZ – Fiber: 1550-nm single-mode – Loopback modes: Terminal and facility – Connectors: SC – Compliance: Telcordia GR-253-CORE • Transmitter – Maximum transmitter output power: +3 dBm – Minimum transmitter output power: –2 dBm – Center wavelength: 1520 to 1580 nm – Nominal wavelength: 1550 nm – Transmitter: DFB laser • Receiver – Maximum receiver level: –8 dBm – Minimum receiver level: –28 dBm – Receiver: InGaAs avalanche photo diode (APD) photodetector – Link loss budget: 26 dB minimum, with 1 dB dispersion penalty – Receiver input wavelength range: 1520 to 1580 nm • Environmental – Operating temperature: C-Temp (15454-OC481LR1550): +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 26.80 W, 0.56 A, 91.50 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 1.8 lb (0.8 kg) A.6.9 OC48 IR/STM16 SH AS 1310 Card Specifications The OC48 IR/STM16 SH AS 1310 card has the following specifications: • Line – Bit rate: 2.49 Gbps Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-35 Appendix A Hardware Specifications A.6.10 OC48 LR/STM16 LH AS 1550 Card Specifications – Code: Scrambled NRZ – Fiber: 1310-nm single-mode – Loopback modes: Terminal and facility – Connectors: SC – Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957 • Transmitter – Maximum transmitter output power: 0 dBm – Minimum transmitter output power: –5 dBm – Center wavelength: 1280 to 1350 nm – Nominal wavelength: 1310 nm – Transmitter: DFB laser – Dispersion tolerance: 96 ps/nm • Receiver – Maximum receiver level: 0 dBm – Minimum receiver level: –18 dBm – Receiver: InGaAs InP photodetector – Link loss budget: 13 dB minimum – Receiver input wavelength range: 1280 to 1350 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Environmental – Operating temperature: C-Temp (15454-OC481IR1310A): +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 37.20 W, 0.77 A, 127.01 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 2.2 lb (0.9 kg) A.6.10 OC48 LR/STM16 LH AS 1550 Card Specifications The OC48 LR/STM16 SH AS 1550 card has the following specifications: • Line – Bit rate: 2.49 Gbps – Code: Scrambled NRZ – Fiber: 1550-nm single-mode – Loopback modes: Terminal and facility Cisco ONS 15454 Reference Manual, R8.5.x A-36 78-18106-01 Appendix A Hardware Specifications A.6.11 OC48 ELR/STM 16 EH 100 GHz Card Specifications – Connectors: SC – Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957 • Transmitter – Maximum transmitter output power: +3 dBm – Minimum transmitter output power: –2 dBm – Center wavelength: 1520 to 1580 nm – Nominal wavelength: 1550 nm – Transmitter: DFB laser – Dispersion ratio: 3600 ps/nm • Receiver – Maximum receiver level: –8 dBm – Minimum receiver level: –28 dBm – Receiver: InGaAs APD photodetector – Link loss budget: 26 dB minimum, with 1 dB dispersion penalty – Receiver input wavelength range: 1520 to 1580 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Environmental – Operating temperature: C-Temp (15454-OC481LR1550A): +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 37.20 W, 0.77 A, 127.01 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 2.2 lb (0.9 kg) A.6.11 OC48 ELR/STM 16 EH 100 GHz Card Specifications The OC48 ELR 100 GHz card has the following specifications: • Line – Bit rate: 2.49 Gbps – Code: Scrambled NRZ – Fiber: 1550-nm single-mode – Loopback modes: Terminal and facility – Connectors: SC – Compliance: Telcordia GR-253-CORE, ITU-T G.692, ITU-T G.958 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-37 Appendix A Hardware Specifications A.6.12 OC48 ELR 200 GHz Card Specifications • Transmitter – Maximum transmitter output power: 0 dBm – Minimum transmitter output power: –2 dBm – Center wavelength accuracy: +/– 0.12 nm – Transmitter: Electro-absorption laser – Dispersion tolerance: 5400 ps/nm • Receiver – Maximum receiver level: –9 dBm – Minimum receiver level: –27 dBm at 1E–12 BER – Receiver: InGaAs APD photodetector – Link loss budget: 25 dB minimum at 1E–12 BER (not including the power dispersion penalty) – Dispersion penalty: 2 dB for a dispersion of up to 5400 ps/nm – Receiver input wavelength range: 1520 to 1580 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Environmental – Operating temperature: C-Temp: +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 31.20 W, 0.65 A, 106.53 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 2.4 lb (1.1 kg) A.6.12 OC48 ELR 200 GHz Card Specifications The OC48 ELR 200 GHz card has the following specifications: • Line – Bit rate: 2.49 Gbps – Code: Scrambled NRZ – Fiber: 1550-nm single-mode – Loopback modes: Terminal and facility – Connectors: SC – Compliance: Telcordia GR-253-CORE, ITU-T G692, ITU-T G958 • Transmitter – Maximum transmitter output power: 0 dBm – Minimum transmitter output power: –2 dBm – Center wavelength accuracy: +/– 0.25 nm Cisco ONS 15454 Reference Manual, R8.5.x A-38 78-18106-01 Appendix A Hardware Specifications A.6.13 OC192 SR/STM64 IO 1310 Card Specifications – Transmitter: Electro-absorption laser – Dispersion tolerance: 3600 ps/nm • Receiver – Maximum receiver level: –8 dBm – Minimum receiver level: –28 dBm – Receiver: InGaAs APD photodetector – Link loss budget: 26 dB minimum, with 1 dB dispersion penalty – Receiver input wavelength range: 1520 to 1580 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Environmental – Operating temperature: C-Temp: +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 31.20 W, 0.65 A, 106.53 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 2.9 lb (1.3 kg) A.6.13 OC192 SR/STM64 IO 1310 Card Specifications The OC192 SR/STM64 IO 1310 card has the following specifications: • Line – Bit rate: 9.95328 Gbps – Code: Scrambled NRZ – Fiber: 1310-nm single-mode – Maximum chromatic dispersion allowance: 6.6 ps/nm – Loopback modes: Terminal and facility – Connectors: SC – Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957, ITU-T G.691 • Transmitter – Maximum transmitter output power: –1 dBm – Minimum transmitter output power: –6 dBm – Center wavelength: 1290 to 1330 nm – Nominal wavelength: 1310 nm – Transmitter: Directly modulated laser • Receiver Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-39 Appendix A Hardware Specifications A.6.14 OC192 IR/STM64 SH 1550 Card Specifications – Maximum receiver level: –1 dBm at BER 1 * 10 exp – 12 – Minimum receiver level: –11 dBm at BER 1 * 10 exp – 12 – Receiver: PIN diode – Link loss budget: 5 dB minimum, plus 1 dB dispersion penalty at BER = 1 * 10 exp – 12 including dispersion – Receiver input wavelength range: 1290 to 1330 nm – Dispersion tolerance: 6.6 ps/nm • Environmental – Operating temperature: +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 47.00 W, 0.98 A at –48 V, 160.5 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 3.1 lb (1.3 kg) A.6.14 OC192 IR/STM64 SH 1550 Card Specifications The OC192 IR/STM64 SH 1550 card has the following specifications: • Line – Bit rate: 9.95328 Gbps – Code: Scrambled NRZ – Fiber: 1550-nm single-mode – Maximum chromatic dispersion allowance: 800 ps/nm – Loopback modes: Terminal and facility Note You must use a 3 to 15 dB fiber attenuator (5 dB recommended) when working with the OC192 IR/STM64 SH 1550 card in a loopback. Do not use fiber loopbacks with the OC192 IR/STM64 SH 1550 card. Using fiber loopbacks can cause irreparable damage to the OC192 IR/STM64 SH 1550 card. – Connectors: SC – Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957, ITU-T G.691 • Transmitter – Maximum transmitter output power: +2 dBm – Minimum transmitter output power: –1 dBm – Center wavelength: 1530 to 1565 nm Cisco ONS 15454 Reference Manual, R8.5.x A-40 78-18106-01 Appendix A Hardware Specifications A.6.15 OC192 LR/STM64 LH 1550 Card Specifications – Nominal wavelength: 1550 nm – Transmitter: Cooled EA (European accreditation) modulated laser • Receiver – Maximum receiver level: –1 dBm at BER 1 * 10 exp – 12 – Minimum receiver level: –14 dBm at BER 1 * 10 exp – 12 – Receiver: PIN diode – Link loss budget: 13 dB minimum, plus 2 dB dispersion penalty at BER = 1 * 10 exp – 12 including dispersion – Receiver input wavelength range: 1530 to 1565 nm – Dispersion tolerance: 800 ps/nm • Environmental – Operating temperature: +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 50.00 W, 1.04 A at –48 V, 170.7 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 3.1 lb (1.3 kg) A.6.15 OC192 LR/STM64 LH 1550 Card Specifications The OC192 LR/STM64 LH 1550 card has the following specifications: • Line – Bit rate: 9.95328 Gbps – Code: Scrambled NRZ – Fiber: 1550-nm single-mode – Loopback modes: Terminal and facility Note You must use a fiber attenuator when connecting a fiber loopback to an OC192 LR/STM64 LH 1550 card. Use a 19 to 24 dB attenuator for 15454-OC192LR1550 or a 14 to 28 dB attenuator for 15454-OC192-LR2 (20 dB is recommended). Never connect a direct fiber loopback. – Connectors: SC – Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957 • Transmitter – Maximum transmitter output power: +10 dBm (15454-OC192LR1550); +7 dBm (15454-OC192-LR2) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-41 Appendix A Hardware Specifications A.6.16 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications – Minimum transmitter output power: +7 dBm (15454-OC192LR1550); +4 dBm (15454-OC192-LR2) – Center wavelength: 1530 to 1565 nm – Nominal wavelength: 1550 nm – Maximum chromatic dispersion allowed: 1600 ps/nm – Transmitter: LN (Lithium Niobate) external modulator transmitter • Receiver – Maximum receiver level: –10 dBm (15454-OC192LR1550); –7 dBm (15454-OC192LR1550) – Minimum receiver level: –19 dBm (15454-OC192LR1550); –24 dBm from 1530 to 1565 nm –20 dBm from 1290 to 1330 nm (15454-OC192-LR2) – Receiver: APD/TIA – Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at BER = 1 – exp (–12) including dispersion – Receiver input wavelength range: 1530 to 1565 nm – Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant • Environmental – Operating temperature: C-Temp (15454-OC192LR1550): +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 72.20 W, 1.50 A, 246.52 BTU/hr (15454-OC192LR1550); 52.00 W, 1.08 A at –48 V, 177.6 BTU/hr (15454-OC192-LR2) • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Weight not including clam shell: 3.1 lb (1.3 kg) A.6.16 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications The OC192 LR/STM64 LH ITU 15xx.xx card has the following specifications: • Line – Bit rate: 9.95328 Gbps – Code: Scrambled NRZ – Fiber: 1550-nm single-mode – Maximum chromatic dispersion allowance: Cisco ONS 15454 Reference Manual, R8.5.x A-42 78-18106-01 Appendix A Hardware Specifications A.6.16 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications In deployments with a dispersion compensation unit (DCU): +/– 1000 ps/nm, with optical signal-to-noise ration (OSNR) of 19 dB (0.5 nm resolution bandwidth [RBW]) In deployments without a DCU: +/– 1200 ps/nm, with OSNR of 23 dB (0.5 nm RBW) – Loopback modes: Terminal and facility Note You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the OC192 LR/STM64 LH 15xx.xx card in a loopback. Do not use fiber loopbacks with the OC192 LR/STM64 LH 15xx.xx card. Using fiber loopbacks causes irreparable damage to this card. – Connectors: SC – Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.691, ITU-T G.957 • Transmitter – Maximum transmitter output power: +6 dBm – Minimum transmitter output power: +3 dBm – Center wavelength: See wavelength plan – Center wavelength accuracy: +/– 0.040 nm – Transmitter: LN external modulator transmitter • Receiver – Maximum receiver level: –8 dBm at BER 1 * 10 exp – 12 – Minimum receiver level: –22 dBm at BER 1 * 10 exp – 12 – Receiver: APD – Link loss budget: 25 dB minimum, plus 2 dB dispersion penalty at BER = 1 * 10 exp – 12 including dispersion – Receiver input wavelength range: 1529 to 1565 nm • Environmental – Operating temperature: +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 52.00 W, 1.08 A at –48 V, 177.6 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 3.1 lb (1.3 kg) • Currently available wavelengths and versions of OC192 LR/STM64 LH ITU 15xx.xx card: ITU grid blue band: – 1534.25 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1534.25 – 1535.04 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1535.04 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-43 Appendix A Hardware Specifications A.6.17 15454_MRC-12 Card Specifications – 1535.82 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1535.82 – 1536.61 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1536.61 – 1538.19 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1538.19 – 1538.98 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1538.98 – 1539.77 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1539.77 – 1540.56 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1540.56 ITU grid red band: – 1550.12 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1550.12 – 1550.92 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1550.92 – 1551.72 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1551.72 – 1552.52 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1552.52 – 1554.13 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1554.13 – 1554.94 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1554.94 – 1555.75 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1555.75 – 1556.55 +/– 0.040 nm, OC192 LR/STM64 LH ITU 1556.55 A.6.17 15454_MRC-12 Card Specifications The 15454_MRC-12 card has the following specifications: • Line – Bit rate: up to OC-48 (2488.320 Mbps), depending on SFP Note Each optical interface on the card can be configured as OC-3, OC-12, or OC-48, depending on the available backplane bandwidth and existing provisioned lines. In general, the card supports all different rates on the line side as long as the accumulated bandwidth does not exceed the total backplane allowed bandwidth. – Fiber: 1550-nm single-mode – Connectors: LC duplex connector for each SFP – Compliance: Telcordia GR-253-CORE • Transmitter – Maximum transmitter output power: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Minimum transmitter output power: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Center wavelength: See wavelength plan – Center wavelength accuracy: 1 nm to 4 nm, depending on SFP – Transmitter: FP and DFB laser • Receiver Cisco ONS 15454 Reference Manual, R8.5.x A-44 78-18106-01 Appendix A Hardware Specifications A.6.18 MRC-2.5G-4 Card Specifications – Maximum receiver level: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Minimum receiver level: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Receiver: PIN PD – Receiver input wavelength range: Depends on SFP • Environmental – Operating temperature: –40 to +149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 38.00 W, 0.79 A at –48 V, 129.66 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 3.1 lb (1.3 kg) • Wavelength plan. Currently available wavelengths and versions of the 15454_MRC-12 card: – For ONS-SC-2G-28.7 through ONS-SC-2G-60.0 SFPs: 1527.77 nm to 1560.61 nm (32 distinct wavelengths at 100 GHz spacing) ONS-SC-2G-28.7, ONS-SC-2G-33.4, ONS-SC-2G-41.3, ONS-SC-2G-49.3, and ONS-SC-2G-57.3 are supported from Release 8.5 and later. Note – For ONS-SE-622-1470 through ONS-SE-622-1610 SFPs: 1470 to 1610 nm (eight distinct wavelengths at 2500 GHz spacing) – For ONS_SE-155-1470 through ONS-SE-155-1610 SFPs: 1470 to 1610 nm (eight distinct wavelengths at 2500 GHz spacing) A.6.18 MRC-2.5G-4 Card Specifications The MRC-2.5G-4 card has the following specifications: • Line – Bit rate: up to OC-48 (2488.320 Mbps), depending on SFP Note Each optical interface on the card can be configured as OC-3, OC-12, or OC-48, depending on the available backplane bandwidth and existing provisioned lines. In general, the card supports all different rates on the line side as long as the accumulated bandwidth does not exceed the total backplane allowed bandwidth. – Fiber: 1550-nm single-mode – Connectors: LC duplex connector for each SFP Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-45 Appendix A Hardware Specifications A.6.18 MRC-2.5G-4 Card Specifications – Compliance: Telcordia GR-253-CORE • Transmitter – Maximum transmitter output power: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Minimum transmitter output power: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Center wavelength: See wavelength plan – Center wavelength accuracy: 1 nm to 4 nm, depending on SFP – Transmitter: FP and DFB laser • Receiver – Maximum receiver level: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Minimum receiver level: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Receiver: PIN PD – Receiver input wavelength range: Depends on SFP • Environmental – Operating temperature: –40 to +149 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 38.00 W, 0.79 A at –48 V, 129.66 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 3.1 lb (1.3 kg) • Wavelength plan. Currently available wavelengths and versions of the MRC-2.5G-4 card: – For ONS-SC-2G-28.7 through ONS-SC-2G-60.0 SFPs: 1528.77 nm to 1560.61 nm (32 distinct wavelengths at 100 GHz spacing) Note ONS-SC-2G-28.7, ONS-SC-2G-33.4, ONS-SC-2G-41.3, ONS-SC-2G-49.3, and ONS-SC-2G-57.3 are supported from Release 8.5 and later. – For ONS-SE-622-1470 through ONS-SE-622-1610 SFPs: 1470 to 1610 nm (eight distinct wavelengths at 2500 GHz spacing) – For ONS_SE-155-1470 through ONS-SE-155-1610 SFPs: 1470 to 1610 nm (eight distinct wavelengths at 2500 GHz spacing) Cisco ONS 15454 Reference Manual, R8.5.x A-46 78-18106-01 Appendix A Hardware Specifications A.6.19 OC192SR1/STM64IO Short Reach Card Specifications A.6.19 OC192SR1/STM64IO Short Reach Card Specifications Note The OC192SR1/STM64IO Short Reach card is designated as OC192-XFP in CTC. The OC192SR1/STM64IO Short Reach card has the following specifications: • Line – Bit rate: OC-192 (9.9520 Gbps) – Fiber: 1310-nm single-mode – Connectors: LC duplex connector for the XFP – Compliance: Telcordia GR-253-CORE • Transmitter – Maximum transmitter output power: –1 dBm – Minimum transmitter output power: –6 dBm • Receiver – Maximum receiver level: –1 dBm – Minimum receiver level: –11 dBm – Receiver input wavelength range: 1260 to 1565 nm • Environmental – Operating temperature: 32 to +131 degrees Fahrenheit (0 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 40.00 W, 0.83 A at –48 V, 136.49 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 3.1 lb (1.3 kg) A.6.20 OC192/STM64 Any Reach Card Specifications Note The OC192/STM64 Any Reach card is designated as OC192-XFP in CTC. The OC192/STM64 Any Reach card has the following specifications: • Line – Bit rate: OC-192 (9.9520 Gbps) – Fiber: 1310-nm single-mode for ONS-XC-10G-S1 XFP, 1550-nm single mode for ONS-XC-10G-I2 and ONS-XC-10G-L2 XFPs Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-47 Appendix A Hardware Specifications A.7 Ethernet Card Specifications – Connectors: LC duplex connector for the XFPs – Compliance: Telcordia GR-253-CORE • Transmitter – Maximum transmitter output power: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Minimum transmitter output power: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) • Receiver – Maximum receiver level: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Minimum receiver level: Depends on SFP (see A.2 SFP, XFP, and GBIC Specifications, page A-5) – Receiver input wavelength range: 1260 to 1565 nm • Environmental – Operating temperature: 32 to +131 degrees Fahrenheit (0 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 40.00 W, 0.83 A at –48 V, 136.49 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 3.1 lb (1.3 kg) A.7 Ethernet Card Specifications This section includes specifications for the E100T-12, E100T-G, E1000-2, E1000-2-G, CE-1000-4, CE-100T-8, CE-MR-10, G1K-4, ML100T-12, ML1000-2, ML-MR-10, and ML100X-8 cards. For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document. A.7.1 E100T-12 Card Specifications The E100T-12 card has the following specifications: • Environmental – Operating temperature C-Temp (15454-E100T): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 65 W, 1.35 A, 221.93 BTU/hr • Dimensions Cisco ONS 15454 Reference Manual, R8.5.x A-48 78-18106-01 Appendix A Hardware Specifications A.7.2 E100T-G Card Specifications – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 2.3 lb (1.0 kg) A.7.2 E100T-G Card Specifications The E100T-G card has the following specifications: • Environmental – Operating temperature: C-Temp (15454-E100T-G): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 65 W, 1.35 A, 221.93 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 2.3 lb (1.0 kg) A.7.3 E1000-2 Card Specifications The E1000-2 card has the following specifications: • Environmental – Operating temperature: C-Temp (15454-E1000-2): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 53.50 W, 1.11 A, 182.67 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 2.1 lb (0.9 kg) A.7.4 E1000-2-G Card Specifications The E1000-2-G card has the following specifications: • Environmental – Operating temperature: Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-49 Appendix A Hardware Specifications A.7.5 CE-1000-4 Card Specifications C-Temp (15454-E1000-2-G): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 53.50 W, 1.11 A, 182.67 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 2.1 lb (0.9 kg) A.7.5 CE-1000-4 Card Specifications The CE-1000-4 card has the following specifications: • Environmental – Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 60 W, 1.25 A at -48 V, 204.8 BTU/hr • Dimensions – Height: 12.650 in. (321.310 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Card weight: 2.1 lb (0.9 kg) A.7.6 CE-100T-8 Card Specifications The CE-100T-8 card has the following specifications: • Environmental – Operating temperature C-Temp (15454-CE100T): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius) – Operating humidity: 0 to 95 percent, noncondensing – Power consumption: 53 W, 1.1 A, 181.3 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.913 in. (23.19 mm) – Depth: 9.073 in. (230.45 mm) – Card weight: 1.8 lb (0.82 kg) Cisco ONS 15454 Reference Manual, R8.5.x A-50 78-18106-01 Appendix A Hardware Specifications A.7.7 CE-MR-10 Card Specifications A.7.7 CE-MR-10 Card Specifications The CE-MR-10 card has the following specifications: • Environmental – Operating temperature C-Temp (15454-CE-MR-10): 32 to 131 degrees Fahrenheit (0 to +50 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 95 • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 2.3 lb (1.0 kg) A.7.8 G1K-4 Card Specifications The G1K-4 card has the following specifications: • Environmental – Operating temperature: +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 63.00 W, 1.31 A at –48 V, 215.1 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 2.1 lb (0.9 kg) A.7.9 ML100T-12 Card Specifications The ML100T-12 card has the following specifications: • Environmental – Operating temperature: +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 53.00 W, 1.10 A at –48 V, 181.0 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-51 Appendix A Hardware Specifications A.7.10 ML1000-2 Card Specifications – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 2.3 lb (1.0 kg) A.7.10 ML1000-2 Card Specifications The ML1000-2 card has the following specifications: • Environmental – Operating temperature: +23 to +131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 49.00 W, 1.02 A at –48 V, 167.3 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 0.9 kg (2.1 lb) A.7.11 ML100X-8 Card Specifications The ML100X-8 card has the following specifications: • Environmental – Operating temperature: +23 to +131 degrees Fahrenheit (–40 to +65 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 65.00 W, 1.35 A at –48 V, 221.93 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 0.9 kg (2.1 lb) A.7.12 ML-MR-10 Card Specifications The ML-MR-10 card has the following specifications: • Environmental – Operating temperature: +23 to +131 degrees Fahrenheit (–40 to +65 degrees Celsius) Cisco ONS 15454 Reference Manual, R8.5.x A-52 78-18106-01 Appendix A Hardware Specifications A.8 Storage Access Networking Card Specifications – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 100 W • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) – Depth with backplane connector: 9.250 in. (235 mm) – Weight not including clam shell: 0.9 kg (2.1 lb) A.8 Storage Access Networking Card Specifications This section describes the FC_MR-4 (Fibre Channel) card specifications. For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document. • Fibre Channel Support: FC-0 and FC-1 layers of ANSI X3.230 FC-PH • GBIC Line Interface – Bit Rate: 1.0625 Gbit/s single-rate or 1.0625/2.125 dual-rate Gbit/s Fibre Channel (FC) – Wavelength/Fiber/Reach: 850 nm, multimode fiber, 550 m (SX) 1310 nm, single-mode fiber, 10 km (LX) 1550 nm/, single-mode fiber, 80 km (ZX) – Hot pluggable – Auto-detection • Transmitter – Maximum transmitter output power: depends on GBIC type (see Table A-2) – Minimum transmitter output power: depends on GBIC type (see Table A-2) • Receiver – Maximum receiver level: depends on GBIC type (see Table A-2) – Minimum receiver level: depends on GBIC type (see Table A-2) • Environmental – Operating temperature C-Temp (15454-E100T): 23 to 131 degrees Fahrenheit (–5 to +55 degrees Celsius) – Operating humidity: 5 to 95 percent, noncondensing – Power consumption: 60 W, 1.35 A, 221.93 BTU/hr • Dimensions – Height: 12.650 in. (321.3 mm) – Width: 0.716 in. (18.2 mm) – Depth: 9.000 in. (228.6 mm) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 A-53 Appendix A Hardware Specifications A.8 Storage Access Networking Card Specifications – Card weight: 2.59 lb (1.17 kg) Cisco ONS 15454 Reference Manual, R8.5.x A-54 78-18106-01 A P P E N D I X B Administrative and Service States This appendix describes administrative and service states for Cisco ONS 15454 cards, ports, and cross-connects. For circuit state information, refer to Chapter 11, “Circuits and Tunnels.” Entity states in Software Release 5.0 and later are based on the generic state model defined in Telcordia GR-1093-CORE, Issue 2 and ITU-T X.731. This appendix contains the following sections: • B.1 Service States, page B-1 • B.2 Administrative States, page B-2 • B.3 Service State Transitions, page B-3 B.1 Service States Service states include a Primary State (PST), a Primary State Qualifier (PSTQ), and one or more Secondary States (SST). Table B-1 lists the service state PSTs and PSTQs supported by the ONS 15454. Table B-1 ONS 15454 Service State Primary States and Primary State Qualifiers Primary State, Primary State Qualifier Definition IS-NR (In-Service and Normal) The entity is fully operational and will perform as provisioned. OOS-AU (Out-of-Service and Autonomous) The entity is not operational because of an autonomous event. OOS-AUMA (Out-of-Service and Autonomous Management) The entity is not operational because of an autonomous event and has also been manually removed from service. OOS-MA (Out-of-Service and Management) The entity has been manually removed from service. Table B-2 defines the SSTs supported by the ONS 15454. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 B-1 Appendix B Administrative and Service States B.2 Administrative States Table B-2 ONS 15454 Secondary States Secondary State Definition AINS (Automatic In-Service) The entity is delayed before transitioning to the IS-NR service state. The transition to IS-NR depends on the correction of conditions, or on a soak timer. Alarm reporting is suppressed, but traffic is carried. Raised fault conditions, whether or not their alarms are reported, can be retrieved on the CTC Conditions tab or by using the TL1 RTRV-COND command. DSBLD (Disabled) The entity was manually removed from service and does not provide its provisioned functions. All services are disrupted; the entity is unable to carry traffic. Note OC-N ports and connections in the DSBLD state continue to send an Alarm Indication Signal Line (AIS-L). FLT (Fault) The entity has a raised alarm or condition. LPBK (Loopback) The entity is in loopback mode. MEA (Mismatched Equipment) An improper card is installed. For example, an installed card is not compatible with the card preprovisioning or the slot. This SST applies only to cards. MT (Maintenance) The entity has been manually removed from service for a maintenance activity but still performs its provisioned functions. Alarm reporting is suppressed, but traffic is carried. Raised fault conditions, whether or not their alarms are reported, can be retrieved on the CTC Conditions tab or by using the TL1 RTRV-COND command. OOG (Out of Group) The virtual concatenation (VCAT) member cross-connect is not used to carry VCAT group traffic. This state is used to put a member circuit out of the group and to stop sending traffic. OOS-MA,OOG only applies to the cross-connects on an end node where VCAT resides. The cross-connects on intermediate nodes are in the OOS-MA,MT service state. SWDL (Software Download) The card is involved in a software and database download. This SST applies only to cards. UAS (Unassigned) The card is not provisioned in the database. This SST applies only to cards. UEQ (Unequipped) The card is not physically present (that is, an empty slot). This SST applies only to cards. B.2 Administrative States Administrative states are used to manage service states. Administrative states consist of a PST and an SST. Table B-3 lists the administrative states supported by the ONS 15454. See Table B-2 for SST definitions. Note A change in the administrative state of an entity does not change the service state of supporting or supported entities. Cisco ONS 15454 Reference Manual, R8.5.x B-2 78-18106-01 Appendix B Administrative and Service States B.3 Service State Transitions Table B-3 ONS 15454 Administrative States Administrative State (PST,SST) Definition IS Puts the entity in service. IS,AINS Puts the entity in automatic in-service. OOS,DSBLD Removes the entity from service and disables it. OOS,MT Removes the entity from service for maintenance. OOS,OOG (VCAT circuits only) Removes a VCAT cross-connect cross-connect from service and from the group of members. Note Only CE-100T-8 cards in link capacity adjustment scheme (LCAS) mode and FC_MR-4 (enhanced mode) cards in software LCAS (SW-LCAS) mode accept the OOG state. B.3 Service State Transitions This section describes the transition from one service state to the next for cards, ports, and cross-connects. A service state transition is based on the action performed on the entity. Note When an entity is put in the OOS,MT administrative state, the ONS 15454 suppresses all standing alarms on that entity. All alarms and events appear on the Conditions tab. You can change this behavior for the LPBKFACILITY and LPBKTERMINAL alarms. To display these alarms on the Alarms tab, set the NODE.general.ReportLoopbackConditionsOnOOS-MTPorts to TRUE on the NE Defaults tab. B.3.1 Card Service State Transitions Table B-4 lists card service state transitions. Table B-4 ONS 15454 Card Service State Transitions Current Service State Action Next Service State IS-NR Change the administrative state to OOS,MT. OOS-MA,MT Delete the card. OOS-AUMA,UAS Remove the card. OOS-AU,UEQ Reset the card. OOS-AU,SWDL Alarm/condition is raised. OOS-AU,FLT Remove the card. OOS-AU,AINS & UEQ Delete the card. OOS-AUMA,UAS if the card is valid OOS-AU,AINS & MEA OOS-AUMA,MEA & UAS if the card is invalid Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 B-3 Appendix B Administrative and Service States B.3.1 Card Service State Transitions Table B-4 ONS 15454 Card Service State Transitions (continued) Current Service State Action Next Service State OOS-AU,AINS & SWDL Restart completed. IS-NR Remove the card. OOS-AU,AINS & UEQ Insert a valid card. OOS-AU,AINS & SWDL Insert an invalid card. OOS-AU,AINS & MEA Delete the card. OOS-AUMA,UAS & UEQ Remove the card. OOS-AU,UEQ Delete the card. OOS-AUMA,UAS Change the administrative state to OOS,MT. OOS-AUMA,FLT & MT Reset the card. OOS-AU,SWDL Alarm/condition is cleared. IS-NR Remove the card. OOS-AU,UEQ Delete the card. OOS-AUMA,UAS if the card is valid OOS-AU,AINS & UEQ OOS-AU,FLT OOS-AU,MEA OOS-AUMA,MEA & UAS if the card is invalid OOS-AU,SWDL OOS-AU,UEQ OOS-AUMA,FLT & MT OOS-AUMA,MEA & MT Change the administrative state to OOS,MT. OOS-AUMA,MEA & MT Restart completed. IS-NR Remove the card. OOS-AU,UEQ Insert a valid card. OOS-AU,SWDL Insert an invalid card. OOS-AU,MEA Delete the card. OOS-AUMA,UAS & UEQ Change the administrative state to OOS,MT. OOS-AUMA,MT & UEQ Remove the card. OOS-AUMA,MT & UEQ Delete the card. OOS-AUMA,UAS Change the administrative state to IS. OOS-AU,FLT Reset the card. OOS-AUMA,MT & SWDL Alarm/condition is cleared. OOS-MA,MT Change the administrative state to IS. OOS-AU,MEA Remove the card. OOS-AUMA,MT & UEQ Delete the card. OOS-AUMA,UAS if the card is valid OOS-AUMA,MEA & UAS if the card is invalid Cisco ONS 15454 Reference Manual, R8.5.x B-4 78-18106-01 Appendix B Administrative and Service States B.3.2 Port and Cross-Connect Service State Transitions Table B-4 ONS 15454 Card Service State Transitions (continued) Current Service State Action Next Service State OOS-AUMA,MEA & UAS Remove the card. OOS-AUMA,UAS & UEQ Provision the card. OOS-AU,MEA Restart completed. OOS-MA,MT Remove the card. OOS-AUMA,MT & UEQ Change the administrative state to IS. OOS-AU,UEQ Insert a valid card. OOS-AUMA,MT & SWDL Insert an invalid card. OOS-AUMA,MEA & MT Delete the card. OOS-AUMA,UAS & UEQ Remove the card. OOS-AUMA,UAS & UEQ Provision an invalid card. OOS-AU,MEA Provision a valid card. OOS-AU,SWDL Insert a valid card. OOS-AU,SWDL Insert an invalid card. OOS-AUMA,MEA & UAS Preprovision a card. OOS-AU,AINS & UEQ Change the administrative state to IS. IS-NR Delete the card. OOS-AUMA,UAS Remove the card. OOS-AUMA,MT & UEQ Reset the card. OOS-AUMA,MT & SWDL Alarm/condition is raised. OOS-AUMA,FLT & MT OOS-AUMA,MT & SWDL OOS-AUMA,MT & UEQ OOS-AUMA,UAS OOS-AUMA,UAS & UEQ OOS-MA,MT B.3.2 Port and Cross-Connect Service State Transitions Table B-5 lists the port and cross-connect service state transitions. Port states do not impact cross-connect states with one exception. A cross-connect in the OOS-AU,AINS service state cannot transition autonomously into the IS-NR service state until the parent port is in the IS-NR service state. You cannot transition a port from the IS-NR service state to the OOS-MA,DSBLD service state. You must first put the port in the OOS-MA,MT service state. Once a port is in the OOS-MA,MT state, the NODE.general.ForceToOosDsbldStateChange default setting of TRUE allows you to put a port in OOS-MA,DSBLD even if the following conditions exist: • The port is a timing source. • The port is used for line, section, or tunneling DCC. • The port supports 1+1 protection or bidirectional line switched rings (BLSRs). • Cross-connects are present on the port. • Overhead connections or overhead terminations are in use (such as express orderwire, local orderwire, or user data channels [UDCs]). Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 B-5 Appendix B Administrative and Service States B.3.2 Port and Cross-Connect Service State Transitions To change this behavior so that you cannot put a port in OOS-MA,DSBLD if any of these conditions exist, set the NODE.general.ForceToOosDsbldStateChange default setting to FALSE. For the procedure to change node defaults, refer to the “Maintain the Node” chapter in the Cisco ONS 15454 Procedure Guide. The following ports do not support all of the service states listed in Table B-5: • E-Series Ethernet ports do not support service states; these ports are either enabled or disabled. • FC_MR-4 ports support the IS-NR; OOS-MA,DSBLD; and OOS-MA,MT service states; they do not support the OOS-AU,AINS service state. Note Deleting a port or cross-connect removes the entity from the system. The deleted entity does not transition to another service state. Note The DS1 port service state on the DS3XM-12 card is based on the DS3 service state. Table B-5 ONS 15454 Port and Cross-Connect Service State Transitions Current Service State Action Next Service State IS-NR Put the port or cross-connect in the OOS,MT administrative state. OOS-MA,MT Put the port or cross-connect in the IS,AINS administrative state. OOS-AU,AINS1 Put the VCAT cross-connect in the OOS,OOG administrative state. OOS-MA,MT & OOG Alarm/condition is raised. OOS-AU,FLT OOS-AU,FLT & OOG for a VCAT cross-connect OOS-AU,AINS (Cross-connect only) Put the cross-connect in the OOS,DSBLD administrative state. OOS-MA,DSBLD Put the port or cross-connect in the IS administrative state. IS-NR Put the port or cross-connect in the OOS,MT administrative state. OOS-MA,MT Put the port or cross-connect in the OOS,DSBLD administrative state. OOS-MA,DSBLD Put the VCAT cross-connect in the OOS,OOG administrative state. OOS-MA,MT and OOG Alarm/condition is raised. OOS-AU,AINS & FLT OOS-MA,DSBLD & OOG for a VCAT cross-connect OOS-MA,DSBLD & OOG for a VCAT cross-connect OOS-AU,AINS & FLT & OOG for a VCAT cross-connect Cisco ONS 15454 Reference Manual, R8.5.x B-6 78-18106-01 Appendix B Administrative and Service States B.3.2 Port and Cross-Connect Service State Transitions Table B-5 ONS 15454 Port and Cross-Connect Service State Transitions (continued) Current Service State Action Next Service State OOS-AU,AINS & FLT Alarm/condition is cleared. OOS-AU,AINS Put the port or cross-connect in the IS administrative state. OOS-AU,FLT Put the port or cross-connect in the OOS,DSBLD administrative state. OOS-MA,DSBLD Put the port or cross-connect in the OOS,MT administrative state. OOS-AUMA,FLT & MT Put the VCAT cross-connect in the OOS,OOG administrative state. OOS-AUMA,FLT & MT & OOG OOS-AU,AINS & FLT & Alarm/condition is cleared. OOG OOS-AU,FLT OOS-AU,AINS or OOS-MA,MT • If an In Group member is IS-NR or OOS-AU,AINS, the member transitions to OOS-AU,AINS • If an In Group member is OOS-MA,MT, the member transitions to OOS-MA,MT Put the VCAT cross-connect in the IS administrative state. OOS-AU,FLT & OOG Put the VCAT cross-connect in the OOS,DSBLD administrative state. OOS-MA,DSBLD & OOG Put the VCAT cross-connect in the OOS,MT administrative state. OOS-AUMA,FLT & MT & OOG Alarm/condition is cleared. IS-NR Put the port or cross-connect in the IS,AINS administrative state. OOS-AU,AINS & FLT Put the port or cross-connect in the OOS,DSBLD administrative state. OOS-MA,DSBLD Put the port or cross-connect in the OOS,MT administrative state OOS-AUMA,FLT & MT Put the VCAT cross-connect in the OOS,OOG administrative state. OOS-AUMA,FLT & MT & OOG OOS-MA,DSBLD & OOG for a VCAT cross-connect Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 B-7 Appendix B Administrative and Service States B.3.2 Port and Cross-Connect Service State Transitions Table B-5 ONS 15454 Port and Cross-Connect Service State Transitions (continued) Current Service State Action Next Service State OOS-AU,FLT & OOG Alarm/condition is cleared. IS-NR or OOS-MA,MT • If an In Group member is IS-NR or OOS-AU,AINS, the member transitions to IS-NR. • If an In Group member is OOS-MA,MT, the member transitions to OOS-MA,MT Put the VCAT cross-connect in the IS,AINS administrative state. OOS-AU,AINS & FLT & OOG Put the VCAT cross-connect in the OOS,DSBLD administrative state. OOS-MA,DSBLD & OOG Put the VCAT cross-connect in the OOS,MT administrative state. OOS-AUMA,FLT & MT & OOG OOS-AUMA,FLT & LPBK & MT Release the loopback. OOS-AUMA,FLT & MT Alarm/condition is cleared. OOS-MA,LPBK & MT OOS-AUMA,FLT & LPBK & MT & OOG Release the loopback. OOS-AUMA,FLT & MT & OOG Alarm/condition is cleared. OOS-MT,MT & OOG OOS-AUMA,FLT & MT Alarm/condition is cleared. OOS-MA,MT Put the port or cross-connect in the IS administrative state. OOS-AU,FLT Put the port or cross-connect in the IS,AINS administrative state. OOS-AU,AINS & FLT Put the port or cross-connect in the OOS,DSBLD administrative state. OOS-MA,DSBLD Put the port or cross-connect in a loopback. OOS-AUMA,FLT & LPBK & MT Put the VCAT cross-connect in the OOS,OOG administrative state. OOS-AUMA,FLT & MT & OOG OOS-MA,DSBLD & OOG for a VCAT cross-connect Cisco ONS 15454 Reference Manual, R8.5.x B-8 78-18106-01 Appendix B Administrative and Service States B.3.2 Port and Cross-Connect Service State Transitions Table B-5 ONS 15454 Port and Cross-Connect Service State Transitions (continued) Current Service State Action Next Service State OOS-AUMA,FLT & MT Alarm/condition is cleared. & OOG Put the VCAT cross-connect in the IS administrative state. Note OOS-MA,LPBK & MT OOS-AU,AINS & FLT & OOG VCAT In Group members are in the OOS-AU,AINS & FLT or IS-NR service state. Put the VCAT cross-connect in the OOS,DSBLD administrative state. OOS-MA,DSBLD & OOG Put the VCAT cross-connect in the OOS,MT administrative state. OOS-MA,FLT & MT Note OOS-MA,DSBLD OOS-AU,FLT & OOG VCAT In Group members are in the OOS-AU,FLT or IS-NR service state. Put the VCAT cross-connect in the IS,AINS administrative state. Note OOS-MA,MT & OOG VCAT In Group members are in the OOS-MA,FLT & MT service state. Operate a loopback. OOS-MA,FLT & LPBK & MT & OOG Put the port or cross-connect in the IS administrative state. IS-NR Put the port or cross-connect in the IS,AINS administrative state. OOS-AU,AINS Put the port or cross-connect in the OOS,MT administrative state. OOS-MA,MT Put the VCAT cross-connect in the OOS,OOG administrative state. OOS-MA,MT & OOG Release the loopback. OOS-MA,MT Note While in OOS-MA,LPBK & MT, both Cisco Transport Controller (CTC) and Transaction Language One (TL1) allow a cross-connect to be deleted, which also removes the loopback. This applies only to the cross-connect, not the ports. Alarm/condition is raised. OOS-AUMA,FLT & LPBK & MT OOS-AUMA,FLT & LPBK & MT & OOG for a VCAT cross-connect Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 B-9 Appendix B Administrative and Service States B.3.3 Pluggable Equipment Service State Transitions Table B-5 ONS 15454 Port and Cross-Connect Service State Transitions (continued) Current Service State Action Next Service State OOS-MA,LPBK & MT & OOG Alarm/condition is raised. OOS-AUMA,FLT & LPBK & MT & OOG OOS-MA,MT Put the port or cross-connect in the IS administrative state. IS-NR Put the port or cross-connect in the IS,AINS administrative state. OOS-AU,AINS Put the port or cross-connect in the OOS,DSBLD administrative state. OOS-MA,DSBLD Put the port or cross-connect in a loopback. OOS-MA,LPBK & MT Put the VCAT cross-connect in the OOS,OOG administrative state. OOS-MA,MT & OOG Alarm/condition is raised. OOS-AUMA,FLT & MT OOS-MA,DSBLD & OOG for a VCAT cross-connect OOS-AUMA,FLT & MT & OOG for a VCAT cross-connect OOG-MA,MT & OOG Alarm/condition is raised. OOS-AUMA,FLT & MT & OOG 1. For a VCAT cross-connect, an IS-NR to OOS-AU,AINS transition will not occur with a Loss of Multiframe (LOM) or Sequence Mismatch (SQM) condition on the member. B.3.3 Pluggable Equipment Service State Transitions The service state transitions for pluggable equipment are the same as for other equipment with the exceptions listed in Table B-6. Note Pluggable equipment (pluggable interface modules [PIMs] and pluggable port modules [PPMs]) will transition out of the UAS state when inserted if the software can read the EEPROM and identify information on the pluggable equipment. If the software cannot read the pluggable equipment, the equipment is considered invalid and will not transition out of the UAS state. Table B-6 ONS 15454 Pluggable Equipment Service State Transitions Current Service State Action Next Service State IS-NR Reset the pluggable equipment. IS-NR Provision an unsupported service rate. OOS-AU,MEA Pluggable equipment does not work with the board configuration. Cisco ONS 15454 Reference Manual, R8.5.x B-10 78-18106-01 Appendix B Administrative and Service States B.3.3 Pluggable Equipment Service State Transitions Table B-6 ONS 15454 Pluggable Equipment Service State Transitions (continued) Current Service State Action Next Service State OOS-AU,AINS & UEQ Insert valid pluggable equipment. IS-NR Insert pluggable equipment with the incorrect rate. OOS-AU,MEA Pluggable equipment does not work with the board configuration. OOS-AU,MEA Delete unsupported service rate or IS-NR modify provisioning so that the pluggable equipment is no longer a mismatch. OOS-AU,UEQ Insert valid pluggable equipment. OOS-AUMA,MEA & MT Delete unsupported service rate or OOS-MA,MT modify provisioning so that the pluggable equipment is no longer a mismatch. OOS-AUMA,MT & UEQ Insert valid pluggable equipment. OOS-MA,MT OOS-AUMA,UAS Provision valid pluggable equipment. IS-NR OOS-AUMA,UAS & UEQ Insert valid pluggable equipment. IS-NR Insert pluggable equipment with the incorrect rate. OOS-AU,MEA IS-NR Pluggable equipment does not work with the board configuration. OOS-MA,MT Reset the pluggable equipment. OOS-MA,MT Provision an unsupported service rate. OOS-AUMA,MEA & MT Pluggable equipment does not work with the board configuration. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 B-11 Appendix B Administrative and Service States B.3.3 Pluggable Equipment Service State Transitions Cisco ONS 15454 Reference Manual, R8.5.x B-12 78-18106-01 A P P E N D I X C Network Element Defaults Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This appendix describes the factory-configured (default) network element (NE) settings for the Cisco ONS 15454. It includes descriptions of card, node, and Cisco Transport Controller (CTC) default settings. To import, export, or edit the settings, refer to the “Maintain the Node” chapter of the Cisco ONS 15454 Procedure Guide. Cards supported by this platform that are not listed in this appendix are not supported by user-configurable NE defaults settings. To change card settings individually (that is, without directly changing the NE defaults), refer to the “Change Card Settings” chapter of the Cisco ONS 15454 Procedure Guide. To change node settings, refer to the “Change Node Settings” chapter of the Cisco ONS 15454 Procedure Guide. This appendix includes the following sections: • C.1 Network Element Defaults Description, page C-1 • C.2 Card Default Settings, page C-2 • C.3 Node Default Settings, page C-99 • C.4 CTC Default Settings, page C-120 C.1 Network Element Defaults Description The NE defaults are preinstalled on each Cisco ONS 15454 Advanced Timing, Communications, and Control (TCC2) and Advanced Timing, Communications, and Control Plus (TCC2P) card. Cisco also ships a file named 15454-defaults.txt on the CTC software CD in case you want to import the defaults onto existing TCC2/TCC2P cards. The NE defaults include card-level, CTC, and node-level defaults. Changes to card provisioning that are made manually using the procedures in the “Change Card Settings” chapter in the Cisco ONS 15454 Procedure Guide override default settings. If you use the CTC Defaults editor (on the node view Provisioning > Defaults tab) or import a new defaults file, any changes to card or port settings that result only affect cards that are installed or preprovisioned after the defaults have changed. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-1 Appendix C Network Element Defaults C.2 Card Default Settings Changes that are made manually to most node-level default settings override the current settings, whether default or provisioned. If you change node-level default settings, either by using the Defaults editor or by importing a new defaults file, the new defaults reprovision the node immediately for all settings except those relating to protection (1+1 bidirectional switching, 1+1 reversion time, 1+1 revertive switching, bidirectional line switched ring [BLSR] ring reversion time, BLSR ring revertive switching, BLSR span reversion time, and BLSR span revertive switching). Settings relating to protection apply to subsequent provisioning. Note Changing some node-level provisioning through NE defaults can cause CTC disconnection or a reboot of the node in order for the provisioning to take effect. Before you change a default, check in the Side Effects column of the Defaults editor (right-click a column header and select Show Column > Side Effects) and be prepared for the occurrence of any side effects listed for that default. C.2 Card Default Settings The tables in this section list the default settings for each SONET card. Cisco provides several types of user-configurable defaults for Cisco ONS 15454 optical, electrical, storage access networking, and Ethernet (or data) cards. Types of card defaults can be broadly grouped by function, as outlined in the following subsections. For information about individual card settings, refer to the “Change Card Settings” chapter of the Cisco ONS 15454 Procedure Guide. Note To view DWDM card defaults consult the Cisco ONS 15454 DWDM Reference Manual. Note When the card level defaults are changed, the new provisioning done after the defaults have changed is affected. Existing provisioning remains unaffected. The following types of defaults are defined for SONET cards. C.2.1 Configuration Defaults Most card-level and port-level configuration defaults correspond to settings found in the CTC card-level Provisioning tabs. Note The full set of Automatic Laser Shutdown (ALS) configuration defaults can be found in the CTC card-level Maintenance > ALS tab for supported cards. ALS defaults are supported for OC3-8, OC-48ELR, OC-192, OC192-XFP, MRC-2.5G-4, and MRC-12 cards. Configuration defaults that correspond to settings that are reachable from the CTC card-level Provisioning tabs (except as noted) include the following types of options (arranged by CTC subtab): • Line—(DS-N, EC1-12, OC-N, MRC-12, MRC-2.5G-4, G-series, and CE-series cards) Line-level configuration settings. Cisco ONS 15454 Reference Manual, R8.5.x C-2 78-18106-01 Appendix C Network Element Defaults C.2.2 Threshold Defaults Note MRC-12 and MRC-2.5G-4 line configuration defaults are defined on a per OC-N rate basis. • SONET STS—(OC-N and EC1-12 cards) SONET STS-level configuration settings. • Port—(FC_MR-4 cards only) Port line-level configuration, distance extension, and enhanced FC/FICON ISL settings. • Card—(DS1/E1-56, ML-series, and FC_MR-4 cards) Transport mode, operating mode, enable/disable retiming, and port to Virtual Tributary (VT) mapping standard settings (DS1/E1-56 only); or FC_MR-4 card mode settings (FC_MR-4 only); or framing mode (ML-series cards). • DS1—(DS3XM-12 cards only) DS-1 rate virtual port-level line configuration settings. • Broadband Ports—(DS3/EC1-48 cards only) Set the port rate as DS3, EC1, or unassigned (DS3 is the default). • DS3—(DS3/EC1-48 cards only) DS-3 rate port-level line configuration settings. • EC1—(DS3/EC1-48 cards only) EC-1 rate port-level line configuration, section trace, and SONET STS settings. • ALS (card-level Maintenance > ALS tab)—(OC3-8, OC-48ELR, OC-192, OC192-XFP, MRC-2.5G-4, and MRC-12 cards) ALS configuration defaults. • IOS (card-level IOS tab)—(ML-series and RAN-SVC cards) Console port and RADIUS server access settings. • Ether Ports—(CE-series cards) Line configuration settings (including 802 class of service [IEEE 802.1p CoS] and IP type of service [ToS]). • POS Ports—(CE-series cards) Line configuration settings. Note Line configuration defaults for the CE-100T-8 card apply to both Ethernet port and packet-over-SONET (POS) port settings where the same setting exists for both. Note For further information about each card, consult the appropriate card reference chapter, that is,Chapter 3, “Electrical Cards,” Chapter 4, “Optical Cards,” Chapter 5, “Ethernet Cards,” and Chapter 6, “Storage Access Networking Cards.” Note For further information about IOS configuration defaults for ML-series cards, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. C.2.2 Threshold Defaults Threshold default settings define the default cumulative values (thresholds) beyond which a threshold crossing alert (TCA) will be raised, making it possible to monitor the network and detect errors early. Card threshold default settings are provided as follows: • PM thresholds—(DS-N, EC-1, OC-N, MRC-2.5G-4, and MRC-12 cards) Can be expressed in counts or seconds; includes line, electrical path, and SONET thresholds. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-3 Appendix C Network Element Defaults C.2.3 Defaults by Card • Physical Layer thresholds—(OC3-8, OC-192, OC-192XFP, MRC-2.5G-4, and MRC-12 cards) Expressed in percentages; includes optics thresholds. Threshold defaults are defined for near end and/or far end, at 15-minute and one-day intervals. Thresholds are further broken down by type, such as Section, Line, STS, or VT for performance monitoring (PM) thresholds, and TCA (warning) or Alarm for physical thresholds. PM threshold types define the layer to which the threshold applies. Physical threshold types define the level of response expected when the threshold is crossed. Note For full descriptions of the thresholds you can set for each card, see Chapter 15, “Performance Monitoring.” Note For additional information regarding PM parameter threshold defaults as defined by Telcordia specifications, refer to Telcordia GR-820-CORE and GR-253-CORE. C.2.3 Defaults by Card In the tables that follow, card defaults are defined by the default name, its factory-configured value, and the domain of allowable values that you can assign to it. Note Some default values, such as certain thresholds, are interdependent. Before changing a value, review the domain for that default and any other related defaults for potential dependencies. C.2.3.1 DS-1 Card Default Settings Table C-1 lists the DS-1 (DS1-14 and DS1N-14) card default settings. Table C-1 DS-1 Card Default Settings Default Name Default Value Default Domain DS1.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 DS1.config.LineCoding AMI B8ZS, AMI DS1.config.LineLength 0 - 131 ft 0 - 131 ft, 132 - 262 ft, 263 - 393 ft, 394 - 524 ft, 525 - 655 ft DS1.config.LineType D4 ESF, D4, UNFRAMED DS1.config.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS1.config.SendAISOnFacilityLoopback TRUE TRUE, FALSE DS1.config.SendAISOnTerminalLoopback FALSE TRUE, FALSE DS1.config.SendAISVOnDefects FALSE FALSE, TRUE DS1.config.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS DS1.config.TreatLOFAsDefect FALSE FALSE, TRUE DS1.pmthresholds.line.farend.15min.ES 65 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x C-4 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-1 DS-1 Card Default Settings (continued) Default Name Default Value Default Domain DS1.pmthresholds.line.farend.1day.ES 648 (seconds) 0 - 86400 DS1.pmthresholds.line.nearend.15min.CV 13340 (BPV count) 0 - 1388700 DS1.pmthresholds.line.nearend.15min.ES 65 (seconds) 0 - 900 DS1.pmthresholds.line.nearend.15min.LOSS 10 (seconds) 0 - 900 DS1.pmthresholds.line.nearend.15min.SES 10 (seconds) 0 - 900 DS1.pmthresholds.line.nearend.1day.CV 133400 (BPV count) 0 - 133315200 DS1.pmthresholds.line.nearend.1day.ES 648 (seconds) 0 - 86400 DS1.pmthresholds.line.nearend.1day.LOSS 10 (seconds) 0 - 86400 DS1.pmthresholds.line.nearend.1day.SES 100 (seconds) 0 - 86400 DS1.pmthresholds.path.farend.15min.CSS 25 (seconds) 0 - 900 DS1.pmthresholds.path.farend.15min.CV 13296 (BIP count) 0 - 38700 DS1.pmthresholds.path.farend.15min.ES 65 (seconds) 0 - 900 DS1.pmthresholds.path.farend.15min.ESA 25 (seconds) 0 - 900 DS1.pmthresholds.path.farend.15min.ESB 25 (seconds) 0 - 900 DS1.pmthresholds.path.farend.15min.FC 0 (count) 0 - 90 DS1.pmthresholds.path.farend.15min.SEFS 25 (seconds) 0 - 900 DS1.pmthresholds.path.farend.15min.SES 10 (seconds) 0 - 900 DS1.pmthresholds.path.farend.15min.UAS 10 (seconds) 0 - 900 DS1.pmthresholds.path.farend.1day.CSS 25 (seconds) 0 - 86400 DS1.pmthresholds.path.farend.1day.CV 132960 (BIP count) 0 - 3715200 DS1.pmthresholds.path.farend.1day.ES 648 (seconds) 0 - 86400 DS1.pmthresholds.path.farend.1day.ESA 25 (seconds) 0 - 86400 DS1.pmthresholds.path.farend.1day.ESB 25 (seconds) 0 - 86400 DS1.pmthresholds.path.farend.1day.FC 0 (count) 0 - 8640 DS1.pmthresholds.path.farend.1day.SEFS 25 (seconds) 0 - 86400 DS1.pmthresholds.path.farend.1day.SES 100 (seconds) 0 - 86400 DS1.pmthresholds.path.farend.1day.UAS 10 (seconds) 0 - 86400 DS1.pmthresholds.path.nearend.15min.AISS 10 (seconds) 0 - 900 DS1.pmthresholds.path.nearend.15min.CV 13296 (BIP count) 0 - 38700 DS1.pmthresholds.path.nearend.15min.ES 65 (seconds) 0 - 900 DS1.pmthresholds.path.nearend.15min.FC 0 (count) 0 - 90 DS1.pmthresholds.path.nearend.15min.SAS 2 (seconds) 0 - 900 DS1.pmthresholds.path.nearend.15min.SES 10 (seconds) 0 - 900 DS1.pmthresholds.path.nearend.15min.UAS 10 (seconds) 0 - 900 DS1.pmthresholds.path.nearend.1day.AISS 10 (seconds) 0 - 86400 DS1.pmthresholds.path.nearend.1day.CV 132960 (BIP count) 0 - 3715200 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-5 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-1 DS-1 Card Default Settings (continued) Default Name Default Value Default Domain DS1.pmthresholds.path.nearend.1day.ES 648 (seconds) 0 - 86400 DS1.pmthresholds.path.nearend.1day.FC 0 (count) 0 - 8640 DS1.pmthresholds.path.nearend.1day.SAS 17 (seconds) 0 - 86400 DS1.pmthresholds.path.nearend.1day.SES 100 (seconds) 0 - 86400 DS1.pmthresholds.path.nearend.1day.UAS 10 (seconds) 0 - 86400 DS1.pmthresholds.sts.farend.15min.CV 15 (B3 count) 0 - 2160000 DS1.pmthresholds.sts.farend.15min.ES 12 (seconds) 0 - 900 DS1.pmthresholds.sts.farend.15min.FC 10 (count) 0 - 72 DS1.pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900 DS1.pmthresholds.sts.farend.15min.UAS 10 (seconds) 0 - 900 DS1.pmthresholds.sts.farend.1day.CV 125 (B3 count) 0 - 207360000 DS1.pmthresholds.sts.farend.1day.ES 100 (seconds) 0 - 86400 DS1.pmthresholds.sts.farend.1day.FC 10 (count) 0 - 6912 DS1.pmthresholds.sts.farend.1day.SES 7 (seconds) 0 - 86400 DS1.pmthresholds.sts.farend.1day.UAS 10 (seconds) 0 - 86400 DS1.pmthresholds.sts.nearend.15min.CV 15 (B3 count) 0 - 2160000 DS1.pmthresholds.sts.nearend.15min.ES 12 (seconds) 0 - 900 DS1.pmthresholds.sts.nearend.15min.FC 10 (count) 0 - 72 DS1.pmthresholds.sts.nearend.15min.SES 3 (seconds) 0 - 900 DS1.pmthresholds.sts.nearend.15min.UAS 10 (seconds) 0 - 900 DS1.pmthresholds.sts.nearend.1day.CV 125 (B3 count) 0 - 207360000 DS1.pmthresholds.sts.nearend.1day.ES 100 (seconds) 0 - 86400 DS1.pmthresholds.sts.nearend.1day.FC 10 (count) 0 - 6912 DS1.pmthresholds.sts.nearend.1day.SES 7 (seconds) 0 - 86400 DS1.pmthresholds.sts.nearend.1day.UAS 10 (seconds) 0 - 86400 DS1.pmthresholds.vt.farend.15min.CV 15 (BIP8 count) 0 - 2160000 DS1.pmthresholds.vt.farend.15min.ES 12 (seconds) 0 - 900 DS1.pmthresholds.vt.farend.15min.SES 3 (seconds) 0 - 900 DS1.pmthresholds.vt.farend.15min.UAS 10 (seconds) 0 - 900 DS1.pmthresholds.vt.farend.1day.CV 125 (BIP8 count) 0 - 207360000 DS1.pmthresholds.vt.farend.1day.ES 100 (seconds) 0 - 86400 DS1.pmthresholds.vt.farend.1day.SES 7 (seconds) 0 - 86400 DS1.pmthresholds.vt.farend.1day.UAS 10 (seconds) 0 - 86400 DS1.pmthresholds.vt.nearend.15min.CV 15 (BIP8 count) 0 - 2160000 DS1.pmthresholds.vt.nearend.15min.ES 12 (seconds) 0 - 900 DS1.pmthresholds.vt.nearend.15min.SES 3 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x C-6 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-1 DS-1 Card Default Settings (continued) Default Name Default Value Default Domain DS1.pmthresholds.vt.nearend.15min.UAS 10 (seconds) 0 - 900 DS1.pmthresholds.vt.nearend.1day.CV 125 (BIP8 count) 0 - 207360000 DS1.pmthresholds.vt.nearend.1day.ES 100 (seconds) 0 - 86400 DS1.pmthresholds.vt.nearend.1day.SES 7 (seconds) 0 - 86400 DS1.pmthresholds.vt.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.2 DS1/E1-56 Card Default Settings Table C-2 lists the DS1/E1-56 card default settings. Table C-2 DS1/E1-56 Card Default Settings Default Name Default Value Default Domain DS1-E1-56.config.OperatingMode All DS1 All DS1, All E1 DS1-E1-56.config.PortToVtMappingMode GR253 Industry when OperatingMode All E1; GR253, Industry when OperatingMode All DS1 DS1-E1-56.DS1-PORT.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 DS1-E1-56.DS1-PORT.config.Ds1Mapping Asynchronous Asynchronous when LineType UNFRAMED, UNFRAMED; Asynchronous, Byte Synchronous when LineType ESF, D4, E1_MF, E1_CRCMF, AUTO FRAME, J_ESF DS1-E1-56.DS1-PORT.config.FdlMode T1.403 T1.403 when LineType UNFRAMED, AUTO FRAME; T1.403, BFDL when LineType ESF, D4, J_ESF DS1-E1-56.DS1-PORT.config.LineCoding AMI B8ZS, AMI DS1-E1-56.DS1-PORT.config.LineLength 0 - 131 ft 0 - 131 ft, 132 - 262 ft, 263 - 393 ft, 394 524 ft, 525 - 655 ft DS1-E1-56.DS1-PORT.config.LineType UNFRAMED ESF, D4, UNFRAMED, AUTO FRAME, J_ESF DS1-E1-56.DS1-PORT.config.RetimingEnabled FALSE TRUE, FALSE DS1-E1-56.DS1-PORT.config.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS1-E1-56.DS1-PORT.config.SendAISOnFacilityLoopback TRUE TRUE, FALSE DS1-E1-56.DS1-PORT.config.SendAISOnTerminalLoopbac k TRUE TRUE, FALSE DS1-E1-56.DS1-PORT.config.SendAISVOnDefects FALSE FALSE, TRUE DS1-E1-56.DS1-PORT.config.SendDoNotUse FALSE TRUE, FALSE DS1-E1-56.DS1-PORT.config.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-7 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-2 DS1/E1-56 Card Default Settings (continued) Default Name Default Value Default Domain DS1-E1-56.DS1-PORT.config.sonet.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessa geSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessa geSet Generation 2; PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessa geSet N/A DS1-E1-56.DS1-PORT.config.State OOS,DSBLD OOS,DSBLD when LineType AUTO FRAME; IS, OOS,DSBLD, OOS,MT, IS,AINS when LineType ESF, D4, UNFRAMED, J_ESF DS1-E1-56.DS1-PORT.config.SyncMsgIn FALSE FALSE when LineType D4, E1_MF, E1_CRCMF, UNFRAMED, AUTO FRAME; FALSE, TRUE when LineType ESF, J_ESF DS1-E1-56.DS1-PORT.config.TreatLOFAsDefect TRUE FALSE, TRUE DS1-E1-56.DS1-PORT.pmthresholds.line.farend.15min.ES 65 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.line.farend.1day.ES 648 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.line.nearend.15min.CV 13340 (BPV count) 0 - 1388700 DS1-E1-56.DS1-PORT.pmthresholds.line.nearend.15min.ES 65 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.line.nearend.15min.LO 10 (seconds) SS 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.line.nearend.15min.SE S 10 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.line.nearend.1day.CV 133400 (BPV count) 0 - 133315200 DS1-E1-56.DS1-PORT.pmthresholds.line.nearend.1day.ES 648 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.line.nearend.1day.LOS S 10 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.line.nearend.1day.SES 100 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.CSS 25 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.CV 13296 (BIP count) 0 - 38700 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.ES 65 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.ESA 25 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.ESB 25 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.ESF 65 (seconds) E 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x C-8 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-2 DS1/E1-56 Card Default Settings (continued) Default Name Default Value Default Domain DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.ESN 65 (seconds) E 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.FC 0 - 72 10 (count) DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.SEF 25 (seconds) S 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.SES 10 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.SES 10 (seconds) FE 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.SES 10 (seconds) NE 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.UA S 10 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.UA SFE 10 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.15min.UA SNE 10 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.CSS 25 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.CV 132960 (BIP count) 0 - 3715200 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.ES 648 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.ESA 25 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.ESB 25 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.ESFE 648 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.ESNE 648 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.FC 40 (count) 0 - 6912 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.SEFS 25 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.SES 100 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.SESF E 100 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.SESN 100 (seconds) E 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.UAS 10 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.UASF 10 (seconds) E 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.farend.1day.UAS NE 0 - 86400 10 (seconds) DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.15min.AI 10 (seconds) SS 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.15min.C V 0 - 38700 13296 (BIP count) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-9 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-2 DS1/E1-56 Card Default Settings (continued) Default Name Default Value Default Domain DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.15min.ES 65 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.15min.FC 10 (count) 0 - 72 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.15min.SA 2 (seconds) S 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.15min.SE 10 (seconds) S 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.15min.U AS 10 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.1day.AIS S 10 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.1day.CV 132960 (BIP count) 0 - 3715200 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.1day.ES 648 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.1day.FC 40 (count) 0 - 6912 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.1day.SAS 17 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.1day.SES 100 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.path.nearend.1day.UAS 10 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.sts.farend.15min.ES 12 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.sts.farend.15min.FC 10 (count) 0 - 72 DS1-E1-56.DS1-PORT.pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.sts.farend.15min.UAS 10 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.sts.farend.1day.ES 100 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.sts.farend.1day.FC 40 (count) 0 - 6912 DS1-E1-56.DS1-PORT.pmthresholds.sts.farend.1day.SES 7 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.sts.farend.1day.UAS 10 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.sts.nearend.15min.ES 12 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.sts.nearend.15min.FC 10 (count) 0 - 72 DS1-E1-56.DS1-PORT.pmthresholds.sts.nearend.15min.SES 3 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.sts.nearend.15min.UAS 10 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.sts.nearend.1day.ES 100 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.sts.nearend.1day.FC 40 (count) 0 - 6912 DS1-E1-56.DS1-PORT.pmthresholds.sts.nearend.1day.SES 7 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.sts.nearend.1day.UAS 10 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.vt.farend.15min.ES 12 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.vt.farend.15min.FC 10 (count) 0 - 72 DS1-E1-56.DS1-PORT.pmthresholds.vt.farend.15min.SES 3 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.vt.farend.15min.UAS 10 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x C-10 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-2 DS1/E1-56 Card Default Settings (continued) Default Name Default Value Default Domain DS1-E1-56.DS1-PORT.pmthresholds.vt.farend.1day.ES 100 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.vt.farend.1day.FC 40 (count) 0 - 6912 DS1-E1-56.DS1-PORT.pmthresholds.vt.farend.1day.SES 7 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.vt.farend.1day.UAS 10 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.vt.nearend.15min.ES 12 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.vt.nearend.15min.FC 10 (count) 0 - 72 DS1-E1-56.DS1-PORT.pmthresholds.vt.nearend.15min.SES 3 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.vt.nearend.15min.UAS 10 (seconds) 0 - 900 DS1-E1-56.DS1-PORT.pmthresholds.vt.nearend.1day.ES 100 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.vt.nearend.1day.FC 40 (count) 0 - 6912 DS1-E1-56.DS1-PORT.pmthresholds.vt.nearend.1day.SES 7 (seconds) 0 - 86400 DS1-E1-56.DS1-PORT.pmthresholds.vt.nearend.1day.UAS 10 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 DS1-E1-56.E1-PORT.config.LineCoding HDB3 HDB3 DS1-E1-56.E1-PORT.config.LineType E1_UNFRAM ED E1_MF, E1_CRCMF, AUTO FRAME, UNFRAMED DS1-E1-56.E1-PORT.config.RetimingEnabled FALSE TRUE, FALSE DS1-E1-56.E1-PORT.config.SaBit SA Bit 4 SA Bit 4, SA Bit 5, SA Bit 6, SA Bit 7, SA Bit 8 DS1-E1-56.E1-PORT.config.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS1-E1-56.E1-PORT.config.SendAISOnFacilityLoopback TRUE TRUE, FALSE DS1-E1-56.E1-PORT.config.SendAISOnTerminalLoopback TRUE TRUE, FALSE DS1-E1-56.E1-PORT.config.SendAISVOnDefects FALSE FALSE, TRUE DS1-E1-56.E1-PORT.config.SendDoNotUse FALSE TRUE, FALSE DS1-E1-56.E1-PORT.config.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 DS1-E1-56.E1-PORT.config.sonet.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessa geSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessa geSet Generation 2; PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessa geSet N/A DS1-E1-56.E1-PORT.config.State OOS,DSBLD OOS,DSBLD when LineType AUTO FRAME; IS, OOS,DSBLD, OOS,MT, IS,AINS when LineType E1_MF, E1_CRCMF, UNFRAMED Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-11 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-2 DS1/E1-56 Card Default Settings (continued) Default Name Default Value Default Domain DS1-E1-56.E1-PORT.config.SyncMsgIn FALSE FALSE, TRUE DS1-E1-56.E1-PORT.config.TreatLOFAsDefect TRUE FALSE, TRUE DS1-E1-56.E1-PORT.pmthresholds.line.nearend.15min.CV 9 (BPV count) 0 - 1388700 DS1-E1-56.E1-PORT.pmthresholds.line.nearend.15min.ES 65 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.line.nearend.15min.LOS S 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.line.nearend.15min.SES 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.line.nearend.1day.CV 90 (BPV count) 0 - 133315200 DS1-E1-56.E1-PORT.pmthresholds.line.nearend.1day.ES 648 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.line.nearend.1day.LOSS 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.line.nearend.1day.SES 100 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.15min.AIS S 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.15min.BBE 9 (count) 0 - 287100 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.15min.EB 9 (count) 0 - 450000 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.15min.ES 65 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.15min.SES 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.15min.UAS 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.1day.AISS 10 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.1day.BBE 90 (count) 0 - 27561600 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.1day.EB 90 (count) 0 - 43200000 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.1day.ES 648 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.1day.SES 100 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.path.nearend.1day.UAS 10 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.sts.farend.15min.ES 12 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.sts.farend.15min.FC 10 (count) 0 - 72 DS1-E1-56.E1-PORT.pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.sts.farend.15min.UAS 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.sts.farend.1day.ES 100 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.sts.farend.1day.FC 40 (count) 0 - 6912 DS1-E1-56.E1-PORT.pmthresholds.sts.farend.1day.SES 7 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.sts.farend.1day.UAS 10 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.sts.nearend.15min.ES 12 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.sts.nearend.15min.FC 10 (count) 0 - 72 DS1-E1-56.E1-PORT.pmthresholds.sts.nearend.15min.SES 3 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.sts.nearend.15min.UAS 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.sts.nearend.1day.ES 100 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x C-12 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-2 DS1/E1-56 Card Default Settings (continued) Default Name Default Value Default Domain DS1-E1-56.E1-PORT.pmthresholds.sts.nearend.1day.FC 40 (count) 0 - 6912 DS1-E1-56.E1-PORT.pmthresholds.sts.nearend.1day.SES 7 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.sts.nearend.1day.UAS 10 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.vt.farend.15min.ES 65 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.vt.farend.15min.FC 10 (count) 0 - 72 DS1-E1-56.E1-PORT.pmthresholds.vt.farend.15min.SES 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.vt.farend.15min.UAS 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.vt.farend.1day.ES 648 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.vt.farend.1day.FC 40 (count) 0 - 6912 DS1-E1-56.E1-PORT.pmthresholds.vt.farend.1day.SES 100 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.vt.farend.1day.UAS 10 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.vt.nearend.15min.ES 65 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.vt.nearend.15min.FC 10 (count) 0 - 72 DS1-E1-56.E1-PORT.pmthresholds.vt.nearend.15min.SES 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.vt.nearend.15min.UAS 10 (seconds) 0 - 900 DS1-E1-56.E1-PORT.pmthresholds.vt.nearend.1day.ES 648 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.vt.nearend.1day.FC 40 (count) 0 - 6912 DS1-E1-56.E1-PORT.pmthresholds.vt.nearend.1day.SES 100 (seconds) 0 - 86400 DS1-E1-56.E1-PORT.pmthresholds.vt.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.3 DS-3 Card Default Settings Table C-3 lists the DS-3 card default settings. Table C-3 DS-3 Card Default Settings Default Name Default Value Default Domain DS3.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 DS3.config.LineLength 0 - 225 ft 0 - 225 ft, 226 - 450 ft DS3.config.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS3.config.SendAISOnFacilityLoopback TRUE TRUE, FALSE DS3.config.SendAISOnTerminalLoopback FALSE TRUE, FALSE DS3.config.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 DS3.config.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS DS3.pmthresholds.line.nearend.15min.CV 387 (BPV count) 0 - 38700 DS3.pmthresholds.line.nearend.15min.ES 25 (seconds) 0 - 900 DS3.pmthresholds.line.nearend.15min.LOSS 10 (seconds) 0 - 900 DS3.pmthresholds.line.nearend.15min.SES 4 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-13 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-3 DS-3 Card Default Settings (continued) Default Name Default Value Default Domain DS3.pmthresholds.line.nearend.1day.CV 3865 (BPV count) 0 - 3715200 DS3.pmthresholds.line.nearend.1day.ES 250 (seconds) 0 - 86400 DS3.pmthresholds.line.nearend.1day.LOSS 10 (seconds) 0 - 86400 DS3.pmthresholds.line.nearend.1day.SES 40 (seconds) 0 - 86400 DS3.pmthresholds.sts.farend.15min.CV 15 (G1 count) 0 - 2160000 DS3.pmthresholds.sts.farend.15min.ES 12 (seconds) 0 - 900 DS3.pmthresholds.sts.farend.15min.FC 10 (count) 0 - 72 DS3.pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900 DS3.pmthresholds.sts.farend.15min.UAS 10 (seconds) 0 - 900 DS3.pmthresholds.sts.farend.1day.CV 125 (G1 count) 0 - 207360000 DS3.pmthresholds.sts.farend.1day.ES 100 (seconds) 0 - 86400 DS3.pmthresholds.sts.farend.1day.FC 10 (count) 0 - 6912 DS3.pmthresholds.sts.farend.1day.SES 7 (seconds) 0 - 86400 DS3.pmthresholds.sts.farend.1day.UAS 10 (seconds) 0 - 86400 DS3.pmthresholds.sts.nearend.15min.CV 15 (B3 count) 0 - 2160000 DS3.pmthresholds.sts.nearend.15min.ES 12 (seconds) 0 - 900 DS3.pmthresholds.sts.nearend.15min.FC 10 (count) 0 - 72 DS3.pmthresholds.sts.nearend.15min.SES 3 (seconds) 0 - 900 DS3.pmthresholds.sts.nearend.15min.UAS 10 (seconds) 0 - 900 DS3.pmthresholds.sts.nearend.1day.CV 125 (B3 count) 0 - 207360000 DS3.pmthresholds.sts.nearend.1day.ES 100 (seconds) 0 - 86400 DS3.pmthresholds.sts.nearend.1day.FC 10 (count) 0 - 6912 DS3.pmthresholds.sts.nearend.1day.SES 7 (seconds) 0 - 86400 DS3.pmthresholds.sts.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.4 DS3/EC1-48 Card Default Settings Table C-4 lists the DS3/EC1-48 card default settings. Table C-4 DS3/EC1-48 Card Default Settings Default Name Default Value Default Domain DS3-EC1-48.Broadband.portAssignment DS3-PORT DS3-EC1-48.DS3-PORT.config.AINSSoakTime 08:00 00:00, 00:15, 00:30 .. 48:00 (hours:mins) DS3-EC1-48.DS3-PORT.config.FeInhibitLpbk TRUE TRUE, FALSE DS3-EC1-48.DS3-PORT.config.LineLength 0 - 225 ft 0 - 225 ft, 226 - 450 ft UNASSIGNED, DS3-PORT, EC1-PORT Cisco ONS 15454 Reference Manual, R8.5.x C-14 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-4 DS3/EC1-48 Card Default Settings (continued) Default Name Default Value Default Domain DS3-EC1-48.DS3-PORT.config.LineType UNFRAME D UNFRAMED, M13, C BIT, AUTO PROVISION FMT DS3-EC1-48.DS3-PORT.config.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS3-EC1-48.DS3-PORT.config.SendAISOnFacilityLoopback TRUE TRUE, FALSE DS3-EC1-48.DS3-PORT.config.SendAISOnTerminalLoopback FALSE TRUE, FALSE DS3-EC1-48.DS3-PORT.config.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 DS3-EC1-48.DS3-PORT.config.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.farend.15min.CV 382 (BIP count) 0 - 38700 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.farend.15min.ES 25 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.farend.15min.SAS 2 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.farend.15min.SES 4 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.farend.15min.UAS 10 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.farend.1day.CV 3820 (BIP count) 0 - 3715200 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.farend.1day.ES 250 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.farend.1day.SAS 8 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.farend.1day.SES 40 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.farend.1day.UAS 10 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.nearend.15min.CV 382 (BIP count) 0 - 38700 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.nearend.15min.ES 25 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.nearend.15min.SAS 2 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.nearend.15min.SES 4 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.nearend.15min.UAS 10 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.nearend.1day.CV 3820 (BIP count) 0 - 3715200 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.nearend.1day.ES 250 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.nearend.1day.SAS 8 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.nearend.1day.SES 40 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.cpbitpath.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.line.nearend.15min.CV 387 (BPV count) 0 - 38700 DS3-EC1-48.DS3-PORT.pmthresholds.line.nearend.15min.ES 25 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.line.nearend.15min.LOSS 10 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.line.nearend.15min.SES 4 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-15 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-4 DS3/EC1-48 Card Default Settings (continued) Default Name Default Value Default Domain DS3-EC1-48.DS3-PORT.pmthresholds.line.nearend.1day.CV 3865 (BPV count) 0 - 3715200 DS3-EC1-48.DS3-PORT.pmthresholds.line.nearend.1day.ES 250 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.line.nearend.1day.LOSS 10 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.line.nearend.1day.SES 40 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.15min.AISS 10 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.15min.CV 382 (BIP count) 0 - 38700 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.15min.ES 25 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.15min.SAS 2 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.15min.SES 4 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.15min.UAS 10 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.1day.AISS 10 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.1day.CV 3820 (BIP count) 0 - 3715200 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.1day.ES 250 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.1day.SAS 8 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.1day.SES 40 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.pbitpath.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.sts.farend.15min.CV 15 (G1 count) 0 - 2160000 DS3-EC1-48.DS3-PORT.pmthresholds.sts.farend.15min.ES 12 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.sts.farend.15min.FC 10 (count) 0 - 72 DS3-EC1-48.DS3-PORT.pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.sts.farend.15min.UAS 10 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.sts.farend.1day.CV 125 (G1 count) 0 - 207360000 DS3-EC1-48.DS3-PORT.pmthresholds.sts.farend.1day.ES 100 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.sts.farend.1day.FC 10 (count) 0 - 6912 DS3-EC1-48.DS3-PORT.pmthresholds.sts.farend.1day.SES 7 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.sts.farend.1day.UAS 10 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.sts.nearend.15min.CV 15 (B3 count) 0 - 2160000 DS3-EC1-48.DS3-PORT.pmthresholds.sts.nearend.15min.ES 12 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.sts.nearend.15min.FC 10 (count) 0 - 72 DS3-EC1-48.DS3-PORT.pmthresholds.sts.nearend.15min.SES 3 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x C-16 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-4 DS3/EC1-48 Card Default Settings (continued) Default Name Default Value Default Domain DS3-EC1-48.DS3-PORT.pmthresholds.sts.nearend.15min.UAS 10 (seconds) 0 - 900 DS3-EC1-48.DS3-PORT.pmthresholds.sts.nearend.1day.CV 125 (B3 count) 0 - 207360000 DS3-EC1-48.DS3-PORT.pmthresholds.sts.nearend.1day.ES 100 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.sts.nearend.1day.FC 10 (count) 0 - 6912 DS3-EC1-48.DS3-PORT.pmthresholds.sts.nearend.1day.SES 7 (seconds) 0 - 86400 DS3-EC1-48.DS3-PORT.pmthresholds.sts.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.config.line.AINSSoakTime 08:00 00:00, 00:15, 00:30 .. 48:00 (hours:mins) DS3-EC1-48.EC1-PORT.config.line.LineLength 0 - 225 ft 0 - 225 ft, 226 - 450 ft DS3-EC1-48.EC1-PORT.config.line.PJStsMon# 0 (STS #) 0-1 DS3-EC1-48.EC1-PORT.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS3-EC1-48.EC1-PORT.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE DS3-EC1-48.EC1-PORT.config.line.SendAISOnTerminalLoopback FALSE TRUE, FALSE DS3-EC1-48.EC1-PORT.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 DS3-EC1-48.EC1-PORT.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS DS3-EC1-48.EC1-PORT.config.sts.IPPMEnabled FALSE TRUE, FALSE DS3-EC1-48.EC1-PORT.pmthresholds.line.farend.15min.CV 1312 (B2 count) 0 - 137700 DS3-EC1-48.EC1-PORT.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 DS3-EC1-48.EC1-PORT.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.line.farend.1day.CV 13120 (B2 count) 0 - 8850600 DS3-EC1-48.EC1-PORT.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.line.farend.1day.FC 40 (count) 0 - 72 DS3-EC1-48.EC1-PORT.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.line.nearend.15min.CV 1312 (B2 count) 0 - 137700 DS3-EC1-48.EC1-PORT.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 DS3-EC1-48.EC1-PORT.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-17 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-4 DS3/EC1-48 Card Default Settings (continued) Default Name Default Value Default Domain DS3-EC1-48.EC1-PORT.pmthresholds.line.nearend.1day.CV 13120 (B2 count) 0 - 13219200 DS3-EC1-48.EC1-PORT.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 DS3-EC1-48.EC1-PORT.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 138600 DS3-EC1-48.EC1-PORT.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 13305600 DS3-EC1-48.EC1-PORT.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.farend.15min.CV 15 (B3 count) 0 - 2160000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.farend.15min.ES 12 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.farend.15min.FC 10 (count) 0 - 72 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.farend.15min.SES 3 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.farend.15min.UAS 10 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.farend.1day.CV 125 (B3 count) 0 - 207360000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.farend.1day.ES 100 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.farend.1day.FC 10 (count) 0 - 6912 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.farend.1day.SES 7 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.farend.1day.UAS 10 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 Cisco ONS 15454 Reference Manual, R8.5.x C-18 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-4 DS3/EC1-48 Card Default Settings (continued) Default Name Default Value Default Domain DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.FC 10 (count) 0 - 6912 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 DS3-EC1-48.EC1-PORT.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.5 DS3E Card Default Settings Table C-5 lists the DS3E card default settings. Table C-5 DS3E Card Default Settings Default Name Default Value Default Domain DS3E.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 DS3E.config.FeInhibitLpbk TRUE TRUE, FALSE DS3E.config.LineLength 0 - 225 ft 0 - 225 ft, 226 - 450 ft DS3E.config.LineType UNFRAMED UNFRAMED, M13, C BIT, AUTO PROVISION FMT Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-19 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-5 DS3E Card Default Settings (continued) Default Name Default Value Default Domain DS3E.config.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS3E.config.SendAISOnFacilityLoopback TRUE TRUE, FALSE DS3E.config.SendAISOnTerminalLoopback FALSE FALSE DS3E.config.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 DS3E.config.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS DS3E.pmthresholds.cpbitpath.farend.15min.CV 382 (BIP count) 0 - 38700 DS3E.pmthresholds.cpbitpath.farend.15min.ES 25 (seconds) 0 - 900 DS3E.pmthresholds.cpbitpath.farend.15min.SAS 2 (seconds) 0 - 900 DS3E.pmthresholds.cpbitpath.farend.15min.SES 4 (seconds) 0 - 900 DS3E.pmthresholds.cpbitpath.farend.15min.UAS 10 (seconds) 0 - 900 DS3E.pmthresholds.cpbitpath.farend.1day.CV 3820 (BIP count) 0 - 3715200 DS3E.pmthresholds.cpbitpath.farend.1day.ES 250 (seconds) 0 - 86400 DS3E.pmthresholds.cpbitpath.farend.1day.SAS 8 (seconds) 0 - 86400 DS3E.pmthresholds.cpbitpath.farend.1day.SES 40 (seconds) 0 - 86400 DS3E.pmthresholds.cpbitpath.farend.1day.UAS 10 (seconds) 0 - 86400 DS3E.pmthresholds.cpbitpath.nearend.15min.CV 382 (BIP count) 0 - 38700 DS3E.pmthresholds.cpbitpath.nearend.15min.ES 25 (seconds) 0 - 900 DS3E.pmthresholds.cpbitpath.nearend.15min.SAS 2 (seconds) 0 - 900 DS3E.pmthresholds.cpbitpath.nearend.15min.SES 4 (seconds) 0 - 900 DS3E.pmthresholds.cpbitpath.nearend.15min.UAS 10 (seconds) 0 - 900 DS3E.pmthresholds.cpbitpath.nearend.1day.CV 3820 (BIP count) 0 - 3715200 DS3E.pmthresholds.cpbitpath.nearend.1day.ES 250 (seconds) 0 - 86400 DS3E.pmthresholds.cpbitpath.nearend.1day.SAS 8 (seconds) 0 - 86400 DS3E.pmthresholds.cpbitpath.nearend.1day.SES 40 (seconds) 0 - 86400 DS3E.pmthresholds.cpbitpath.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3E.pmthresholds.line.nearend.15min.CV 387 (BPV count) 0 - 38700 DS3E.pmthresholds.line.nearend.15min.ES 25 (seconds) 0 - 900 DS3E.pmthresholds.line.nearend.15min.LOSS 10 (seconds) 0 - 900 DS3E.pmthresholds.line.nearend.15min.SES 4 (seconds) 0 - 900 DS3E.pmthresholds.line.nearend.1day.CV 3865 (BPV count) 0 - 3715200 DS3E.pmthresholds.line.nearend.1day.ES 250 (seconds) 0 - 86400 DS3E.pmthresholds.line.nearend.1day.LOSS 10 (seconds) 0 - 86400 DS3E.pmthresholds.line.nearend.1day.SES 40 (seconds) 0 - 86400 DS3E.pmthresholds.pbitpath.nearend.15min.AISS 10 (seconds) 0 - 900 DS3E.pmthresholds.pbitpath.nearend.15min.CV 382 (BIP count) 0 - 38700 DS3E.pmthresholds.pbitpath.nearend.15min.ES 25 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x C-20 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-5 DS3E Card Default Settings (continued) Default Name Default Value Default Domain DS3E.pmthresholds.pbitpath.nearend.15min.SAS 2 (seconds) 0 - 900 DS3E.pmthresholds.pbitpath.nearend.15min.SES 4 (seconds) 0 - 900 DS3E.pmthresholds.pbitpath.nearend.15min.UAS 10 (seconds) 0 - 900 DS3E.pmthresholds.pbitpath.nearend.1day.AISS 10 (seconds) 0 - 86400 DS3E.pmthresholds.pbitpath.nearend.1day.CV 3820 (BIP count) 0 - 3715200 DS3E.pmthresholds.pbitpath.nearend.1day.ES 250 (seconds) 0 - 86400 DS3E.pmthresholds.pbitpath.nearend.1day.SAS 8 (seconds) 0 - 86400 DS3E.pmthresholds.pbitpath.nearend.1day.SES 40 (seconds) 0 - 86400 DS3E.pmthresholds.pbitpath.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3E.pmthresholds.sts.farend.15min.CV 15 (G1 count) 0 - 2160000 DS3E.pmthresholds.sts.farend.15min.ES 12 (seconds) 0 - 900 DS3E.pmthresholds.sts.farend.15min.FC 10 (count) 0 - 72 DS3E.pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900 DS3E.pmthresholds.sts.farend.15min.UAS 10 (seconds) 0 - 900 DS3E.pmthresholds.sts.farend.1day.CV 125 (G1 count) 0 - 207360000 DS3E.pmthresholds.sts.farend.1day.ES 100 (seconds) 0 - 86400 DS3E.pmthresholds.sts.farend.1day.FC 10 (count) 0 - 6912 DS3E.pmthresholds.sts.farend.1day.SES 7 (seconds) 0 - 86400 DS3E.pmthresholds.sts.farend.1day.UAS 10 (seconds) 0 - 86400 DS3E.pmthresholds.sts.nearend.15min.CV 15 (B3 count) 0 - 2160000 DS3E.pmthresholds.sts.nearend.15min.ES 12 (seconds) 0 - 900 DS3E.pmthresholds.sts.nearend.15min.FC 10 (count) 0 - 72 DS3E.pmthresholds.sts.nearend.15min.SES 3 (seconds) 0 - 900 DS3E.pmthresholds.sts.nearend.15min.UAS 10 (seconds) 0 - 900 DS3E.pmthresholds.sts.nearend.1day.CV 125 (B3 count) 0 - 207360000 DS3E.pmthresholds.sts.nearend.1day.ES 100 (seconds) 0 - 86400 DS3E.pmthresholds.sts.nearend.1day.FC 10 (count) 0 - 6912 DS3E.pmthresholds.sts.nearend.1day.SES 7 (seconds) 0 - 86400 DS3E.pmthresholds.sts.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.6 DS3I Card Default Settings Table C-6 lists the DS3I card default settings. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-21 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-6 DS3I Card Default Settings Default Name Default Value Default Domain DS3I.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 DS3I.config.FeInhibitLpbk TRUE TRUE, FALSE DS3I.config.LineLength 0 - 225 ft 0 - 225 ft, 226 - 450 ft DS3I.config.LineType C BIT UNFRAMED, M13, C BIT, AUTO PROVISION FMT DS3I.config.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS3I.config.SendAISOnFacilityLoopback TRUE TRUE, FALSE DS3I.config.SendAISOnTerminalLoopback FALSE TRUE, FALSE DS3I.config.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 DS3I.config.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS DS3I.pmthresholds.cpbitpath.farend.15min.CVCP 382 (BIP count) 0 - 38700 DS3I.pmthresholds.cpbitpath.farend.15min.ESCP 25 (seconds) 0 - 900 DS3I.pmthresholds.cpbitpath.farend.15min.SASCP 2 (seconds) 0 - 900 DS3I.pmthresholds.cpbitpath.farend.15min.SESCP 4 (seconds) 0 - 900 DS3I.pmthresholds.cpbitpath.farend.15min.UASCP 10 (seconds) 0 - 900 DS3I.pmthresholds.cpbitpath.farend.1day.CVCP 3820 (BIP count) 0 - 3715200 DS3I.pmthresholds.cpbitpath.farend.1day.ESCP 250 (seconds) 0 - 86400 DS3I.pmthresholds.cpbitpath.farend.1day.SASCP 8 (seconds) 0 - 86400 DS3I.pmthresholds.cpbitpath.farend.1day.SESCP 40 (seconds) 0 - 86400 DS3I.pmthresholds.cpbitpath.farend.1day.UASCP 10 (seconds) 0 - 86400 DS3I.pmthresholds.cpbitpath.nearend.15min.CVCP 382 (BIP count) 0 - 38700 DS3I.pmthresholds.cpbitpath.nearend.15min.ESCP 25 (seconds) 0 - 900 DS3I.pmthresholds.cpbitpath.nearend.15min.SASCP 2 (seconds) 0 - 900 DS3I.pmthresholds.cpbitpath.nearend.15min.SESCP 4 (seconds) 0 - 900 DS3I.pmthresholds.cpbitpath.nearend.15min.UASCP 10 (seconds) 0 - 900 DS3I.pmthresholds.cpbitpath.nearend.1day.CVCP 3820 (BIP count) 0 - 3715200 DS3I.pmthresholds.cpbitpath.nearend.1day.ESCP 250 (seconds) 0 - 86400 DS3I.pmthresholds.cpbitpath.nearend.1day.SASCP 8 (seconds) 0 - 86400 DS3I.pmthresholds.cpbitpath.nearend.1day.SESCP 40 (seconds) 0 - 86400 DS3I.pmthresholds.cpbitpath.nearend.1day.UASCP 10 (seconds) 0 - 86400 DS3I.pmthresholds.line.nearend.15min.CV 387 (BPV count) 0 - 38700 DS3I.pmthresholds.line.nearend.15min.ES 25 (seconds) 0 - 900 DS3I.pmthresholds.line.nearend.15min.LOSS 10 (seconds) 0 - 900 DS3I.pmthresholds.line.nearend.15min.SES 4 (seconds) 0 - 900 DS3I.pmthresholds.line.nearend.1day.CV 3865 (BPV count) 0 - 3715200 Cisco ONS 15454 Reference Manual, R8.5.x C-22 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-6 DS3I Card Default Settings (continued) Default Name Default Value Default Domain DS3I.pmthresholds.line.nearend.1day.ES 250 (seconds) 0 - 86400 DS3I.pmthresholds.line.nearend.1day.LOSS 10 (seconds) 0 - 86400 DS3I.pmthresholds.line.nearend.1day.SES 40 (seconds) 0 - 86400 DS3I.pmthresholds.pbitpath.nearend.15min.AISSP 10 (seconds) 0 - 900 DS3I.pmthresholds.pbitpath.nearend.15min.CVP 382 (BIP count) 0 - 38700 DS3I.pmthresholds.pbitpath.nearend.15min.ESP 25 (seconds) 0 - 900 DS3I.pmthresholds.pbitpath.nearend.15min.SASP 2 (seconds) 0 - 900 DS3I.pmthresholds.pbitpath.nearend.15min.SESP 4 (seconds) 0 - 900 DS3I.pmthresholds.pbitpath.nearend.15min.UASP 10 (seconds) 0 - 900 DS3I.pmthresholds.pbitpath.nearend.1day.AISSP 10 (seconds) 0 - 86400 DS3I.pmthresholds.pbitpath.nearend.1day.CVP 3820 (BIP count) 0 - 3715200 DS3I.pmthresholds.pbitpath.nearend.1day.ESP 250 (seconds) 0 - 86400 DS3I.pmthresholds.pbitpath.nearend.1day.SASP 8 (seconds) 0 - 86400 DS3I.pmthresholds.pbitpath.nearend.1day.SESP 40 (seconds) 0 - 86400 DS3I.pmthresholds.pbitpath.nearend.1day.UASP 10 (seconds) 0 - 86400 DS3I.pmthresholds.sts.farend.15min.CV 15 (G1 count) 0 - 2160000 DS3I.pmthresholds.sts.farend.15min.ES 12 (seconds) 0 - 900 DS3I.pmthresholds.sts.farend.15min.FC 10 (count) 0 - 72 DS3I.pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900 DS3I.pmthresholds.sts.farend.15min.UAS 10 (seconds) 0 - 900 DS3I.pmthresholds.sts.farend.1day.CV 125 (G1 count) 0 - 207360000 DS3I.pmthresholds.sts.farend.1day.ES 100 (seconds) 0 - 86400 DS3I.pmthresholds.sts.farend.1day.FC 10 (count) 0 - 6912 DS3I.pmthresholds.sts.farend.1day.SES 7 (seconds) 0 - 86400 DS3I.pmthresholds.sts.farend.1day.UAS 10 (seconds) 0 - 86400 DS3I.pmthresholds.sts.nearend.15min.CV 15 (B3 count) 0 - 2160000 DS3I.pmthresholds.sts.nearend.15min.ES 12 (seconds) 0 - 900 DS3I.pmthresholds.sts.nearend.15min.FC 10 (count) 0 - 72 DS3I.pmthresholds.sts.nearend.15min.SES 3 (seconds) 0 - 900 DS3I.pmthresholds.sts.nearend.15min.UAS 10 (seconds) 0 - 900 DS3I.pmthresholds.sts.nearend.1day.CV 125 (B3 count) 0 - 207360000 DS3I.pmthresholds.sts.nearend.1day.ES 100 (seconds) 0 - 86400 DS3I.pmthresholds.sts.nearend.1day.FC 10 (count) 0 - 6912 DS3I.pmthresholds.sts.nearend.1day.SES 7 (seconds) 0 - 86400 DS3I.pmthresholds.sts.nearend.1day.UAS 10 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-23 Appendix C Network Element Defaults C.2.3 Defaults by Card C.2.3.7 DS3XM-6 Card Default Settings Table C-7 lists the DS3XM-6 card default settings. Table C-7 DS3XM-6 Card Default Settings Default Name Default Value Default Domain DS3XM.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 DS3XM.config.FeInhibitLpbk TRUE TRUE, FALSE DS3XM.config.LineLength 0 - 225 ft 0 - 225 ft, 226 - 450 ft DS3XM.config.LineType M13 M13, C BIT DS3XM.config.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS3XM.config.SendAISOnFacilityLoopback TRUE TRUE, FALSE DS3XM.config.SendAISOnTerminalLoopback FALSE TRUE, FALSE DS3XM.config.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 DS3XM.config.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS DS3XM.pmthresholds.cpbitpath.farend.15min.CV 382 (BIP count) 0 - 38700 DS3XM.pmthresholds.cpbitpath.farend.15min.ES 25 (seconds) 0 - 900 DS3XM.pmthresholds.cpbitpath.farend.15min.SAS 2 (seconds) 0 - 900 DS3XM.pmthresholds.cpbitpath.farend.15min.SES 4 (seconds) 0 - 900 DS3XM.pmthresholds.cpbitpath.farend.15min.UAS 10 (seconds) 0 - 900 DS3XM.pmthresholds.cpbitpath.farend.1day.CV 3820 (BIP count) 0 - 3715200 DS3XM.pmthresholds.cpbitpath.farend.1day.ES 250 (seconds) 0 - 86400 DS3XM.pmthresholds.cpbitpath.farend.1day.SAS 8 (seconds) 0 - 86400 DS3XM.pmthresholds.cpbitpath.farend.1day.SES 40 (seconds) 0 - 86400 DS3XM.pmthresholds.cpbitpath.farend.1day.UAS 10 (seconds) 0 - 86400 DS3XM.pmthresholds.cpbitpath.nearend.15min.CV 382 (BIP count) 0 - 38700 DS3XM.pmthresholds.cpbitpath.nearend.15min.ES 25 (seconds) 0 - 900 DS3XM.pmthresholds.cpbitpath.nearend.15min.SAS 2 (seconds) 0 - 900 DS3XM.pmthresholds.cpbitpath.nearend.15min.SES 4 (seconds) 0 - 900 DS3XM.pmthresholds.cpbitpath.nearend.15min.UAS 10 (seconds) 0 - 900 DS3XM.pmthresholds.cpbitpath.nearend.1day.CV 3820 (BIP count) 0 - 3715200 DS3XM.pmthresholds.cpbitpath.nearend.1day.ES 250 (seconds) 0 - 86400 DS3XM.pmthresholds.cpbitpath.nearend.1day.SAS 8 (seconds) 0 - 86400 DS3XM.pmthresholds.cpbitpath.nearend.1day.SES 40 (seconds) 0 - 86400 DS3XM.pmthresholds.cpbitpath.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3XM.pmthresholds.ds1path.nearend.15min.AISS 10 (seconds) 0 - 900 DS3XM.pmthresholds.ds1path.nearend.15min.ES 65 (seconds) 0 - 900 DS3XM.pmthresholds.ds1path.nearend.15min.SAS 2 (seconds) 0 - 900 DS3XM.pmthresholds.ds1path.nearend.15min.SES 10 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x C-24 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-7 DS3XM-6 Card Default Settings (continued) Default Name Default Value Default Domain DS3XM.pmthresholds.ds1path.nearend.15min.UAS 10 (seconds) 0 - 900 DS3XM.pmthresholds.ds1path.nearend.1day.AISS 10 (seconds) 0 - 86400 DS3XM.pmthresholds.ds1path.nearend.1day.ES 648 (seconds) 0 - 86400 DS3XM.pmthresholds.ds1path.nearend.1day.SAS 17 (seconds) 0 - 86400 DS3XM.pmthresholds.ds1path.nearend.1day.SES 100 (seconds) 0 - 86400 DS3XM.pmthresholds.ds1path.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3XM.pmthresholds.line.nearend.15min.CV 387 (BPV count) 0 - 38700 DS3XM.pmthresholds.line.nearend.15min.ES 25 (seconds) 0 - 900 DS3XM.pmthresholds.line.nearend.15min.LOSS 10 (seconds) 0 - 900 DS3XM.pmthresholds.line.nearend.15min.SES 4 (seconds) 0 - 900 DS3XM.pmthresholds.line.nearend.1day.CV 3865 (BPV count) 0 - 3715200 DS3XM.pmthresholds.line.nearend.1day.ES 250 (seconds) 0 - 86400 DS3XM.pmthresholds.line.nearend.1day.LOSS 10 (seconds) 0 - 86400 DS3XM.pmthresholds.line.nearend.1day.SES 40 (seconds) 0 - 86400 DS3XM.pmthresholds.pbitpath.nearend.15min.AISS 10 (seconds) 0 - 900 DS3XM.pmthresholds.pbitpath.nearend.15min.CV 382 (BIP count) 0 - 38700 DS3XM.pmthresholds.pbitpath.nearend.15min.ES 25 (seconds) 0 - 900 DS3XM.pmthresholds.pbitpath.nearend.15min.SAS 2 (seconds) 0 - 900 DS3XM.pmthresholds.pbitpath.nearend.15min.SES 4 (seconds) 0 - 900 DS3XM.pmthresholds.pbitpath.nearend.15min.UAS 10 (seconds) 0 - 900 DS3XM.pmthresholds.pbitpath.nearend.1day.AISS 10 (seconds) 0 - 86400 DS3XM.pmthresholds.pbitpath.nearend.1day.CV 3820 (BIP count) 0 - 3715200 DS3XM.pmthresholds.pbitpath.nearend.1day.ES 250 (seconds) 0 - 86400 DS3XM.pmthresholds.pbitpath.nearend.1day.SAS 8 (seconds) 0 - 86400 DS3XM.pmthresholds.pbitpath.nearend.1day.SES 40 (seconds) 0 - 86400 DS3XM.pmthresholds.pbitpath.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3XM.pmthresholds.sts.farend.15min.CV 15 (B3 count) 0 - 2160000 DS3XM.pmthresholds.sts.farend.15min.ES 12 (seconds) 0 - 900 DS3XM.pmthresholds.sts.farend.15min.FC 10 (count) 0 - 72 DS3XM.pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900 DS3XM.pmthresholds.sts.farend.15min.UAS 10 (seconds) 0 - 900 DS3XM.pmthresholds.sts.farend.1day.CV 125 (B3 count) 0 - 207360000 DS3XM.pmthresholds.sts.farend.1day.ES 100 (seconds) 0 - 86400 DS3XM.pmthresholds.sts.farend.1day.FC 10 (count) 0 - 6912 DS3XM.pmthresholds.sts.farend.1day.SES 7 (seconds) 0 - 86400 DS3XM.pmthresholds.sts.farend.1day.UAS 10 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-25 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-7 DS3XM-6 Card Default Settings (continued) Default Name Default Value Default Domain DS3XM.pmthresholds.sts.nearend.15min.CV 15 (B3 count) 0 - 2160000 DS3XM.pmthresholds.sts.nearend.15min.ES 12 (seconds) 0 - 900 DS3XM.pmthresholds.sts.nearend.15min.FC 10 (count) 0 - 72 DS3XM.pmthresholds.sts.nearend.15min.SES 3 (seconds) 0 - 900 DS3XM.pmthresholds.sts.nearend.15min.UAS 10 (seconds) 0 - 900 DS3XM.pmthresholds.sts.nearend.1day.CV 125 (B3 count) 0 - 207360000 DS3XM.pmthresholds.sts.nearend.1day.ES 100 (seconds) 0 - 86400 DS3XM.pmthresholds.sts.nearend.1day.FC 10 (count) 0 - 6912 DS3XM.pmthresholds.sts.nearend.1day.SES 7 (seconds) 0 - 86400 DS3XM.pmthresholds.sts.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3XM.pmthresholds.vt.farend.15min.CV 15 (BIP8 count) 0 - 2160000 DS3XM.pmthresholds.vt.farend.15min.ES 12 (seconds) 0 - 900 DS3XM.pmthresholds.vt.farend.15min.SES 3 (seconds) 0 - 900 DS3XM.pmthresholds.vt.farend.15min.UAS 10 (seconds) 0 - 900 DS3XM.pmthresholds.vt.farend.1day.CV 125 (BIP8 count) 0 - 207360000 DS3XM.pmthresholds.vt.farend.1day.ES 100 (seconds) 0 - 86400 DS3XM.pmthresholds.vt.farend.1day.SES 7 (seconds) 0 - 86400 DS3XM.pmthresholds.vt.farend.1day.UAS 10 (seconds) 0 - 86400 DS3XM.pmthresholds.vt.nearend.15min.CV 15 (BIP8 count) 0 - 2160000 DS3XM.pmthresholds.vt.nearend.15min.ES 12 (seconds) 0 - 900 DS3XM.pmthresholds.vt.nearend.15min.SES 3 (seconds) 0 - 900 DS3XM.pmthresholds.vt.nearend.15min.UAS 10 (seconds) 0 - 900 DS3XM.pmthresholds.vt.nearend.1day.CV 125 (BIP8 count) 0 - 207360000 DS3XM.pmthresholds.vt.nearend.1day.ES 100 (seconds) 0 - 86400 DS3XM.pmthresholds.vt.nearend.1day.SES 7 (seconds) 0 - 86400 DS3XM.pmthresholds.vt.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.8 DS3XM-12 Card Default Settings Table C-8 lists the DS3XM-12 card default settings. Table C-8 DS3XM-12 Card Default Settings Default Name Default Value Default Domain DS3XM12.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 DS3XM12.config.FeInhibitLpbk TRUE TRUE, FALSE DS3XM12.config.LineLength 0 - 225 ft (feet) 0 - 225 ft, 226 - 450 ft DS3XM12.config.LineType M13 M13, C BIT Cisco ONS 15454 Reference Manual, R8.5.x C-26 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-8 DS3XM-12 Card Default Settings (continued) Default Name Default Value Default Domain DS3XM12.config.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS3XM12.config.SendAISOnFacilityLoopback TRUE TRUE, FALSE DS3XM12.config.SendAISOnTerminalLoopback FALSE TRUE, FALSE DS3XM12.config.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 DS3XM12.config.State OOS,DSBLD IS, OOS,DSBLD, OOS,MT, IS,AINS DS3XM12.ds1config.FdlMode T1.403 T1.403, BFDL when LineType ESF, D4; T1.403 when LineType UNFRAMED, AUTO FRAME DS3XM12.ds1config.LineType AUTO FRAME ESF, D4, UNFRAMED, AUTO FRAME DS3XM12.pmthresholds.cpbitpath.farend.15min.CV 382 (BIP count) 0 - 38700 DS3XM12.pmthresholds.cpbitpath.farend.15min.ES 25 (seconds) 0 - 900 DS3XM12.pmthresholds.cpbitpath.farend.15min.SAS 2 (seconds) 0 - 900 DS3XM12.pmthresholds.cpbitpath.farend.15min.SES 4 (seconds) 0 - 900 DS3XM12.pmthresholds.cpbitpath.farend.15min.UAS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.cpbitpath.farend.1day.CV 3820 (BIP count) 0 - 3715200 DS3XM12.pmthresholds.cpbitpath.farend.1day.ES 250 (seconds) 0 - 86400 DS3XM12.pmthresholds.cpbitpath.farend.1day.SAS 8 (seconds) 0 - 86400 DS3XM12.pmthresholds.cpbitpath.farend.1day.SES 40 (seconds) 0 - 86400 DS3XM12.pmthresholds.cpbitpath.farend.1day.UAS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.cpbitpath.nearend.15min.CV 382 (BIP count) 0 - 38700 DS3XM12.pmthresholds.cpbitpath.nearend.15min.ES 25 (seconds) 0 - 900 DS3XM12.pmthresholds.cpbitpath.nearend.15min.SAS 2 (seconds) 0 - 900 DS3XM12.pmthresholds.cpbitpath.nearend.15min.SES 4 (seconds) 0 - 900 DS3XM12.pmthresholds.cpbitpath.nearend.15min.UAS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.cpbitpath.nearend.1day.CV 3820 (BIP count) 0 - 3715200 DS3XM12.pmthresholds.cpbitpath.nearend.1day.ES 250 (seconds) 0 - 86400 DS3XM12.pmthresholds.cpbitpath.nearend.1day.SAS 8 (seconds) 0 - 86400 DS3XM12.pmthresholds.cpbitpath.nearend.1day.SES 40 (seconds) 0 - 86400 DS3XM12.pmthresholds.cpbitpath.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.15min.AISS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.CSS 25 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.CV 13296 (count) 0 - 287100 DS3XM12.pmthresholds.ds1path.farend.15min.ES 65 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.ESA 25 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.ESB 25 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.ESFE 65 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.ESNE 65 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-27 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-8 DS3XM-12 Card Default Settings (continued) Default Name Default Value Default Domain DS3XM12.pmthresholds.ds1path.farend.15min.SEFS 25 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.SES 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.SESFE 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.SESNE 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.UAS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.UASFE 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.15min.UASNE 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.farend.1day.AISS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.CSS 25 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.CV 132960 (count) 0 - 27561600 DS3XM12.pmthresholds.ds1path.farend.1day.ES 648 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.ESA 25 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.ESB 25 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.ESFE 648 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.ESNE 648 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.SEFS 25 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.SES 100 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.SESFE 100 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.SESNE 100 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.UAS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.UASFE 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.farend.1day.UASNE 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.nearend.15min.AISS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.nearend.15min.CV 13296 (count) 0 - 287100 DS3XM12.pmthresholds.ds1path.nearend.15min.ES 65 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.nearend.15min.FC 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.nearend.15min.SAS 2 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.nearend.15min.SES 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.nearend.15min.UAS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1path.nearend.1day.AISS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.nearend.1day.CV 132960 (count) 0 - 27561600 DS3XM12.pmthresholds.ds1path.nearend.1day.ES 648 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.nearend.1day.FC 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.nearend.1day.SAS 17 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.nearend.1day.SES 100 (seconds) 0 - 86400 DS3XM12.pmthresholds.ds1path.nearend.1day.UAS 10 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x C-28 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-8 DS3XM-12 Card Default Settings (continued) Default Name Default Value Default Domain DS3XM12.pmthresholds.line.nearend.15min.CV 387 (BPV count) 0 - 38700 DS3XM12.pmthresholds.line.nearend.15min.ES 25 (seconds) 0 - 900 DS3XM12.pmthresholds.line.nearend.15min.LOSS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.line.nearend.15min.SES 4 (seconds) 0 - 900 DS3XM12.pmthresholds.line.nearend.1day.CV 3865 (BPV count) 0 - 3715200 DS3XM12.pmthresholds.line.nearend.1day.ES 250 (seconds) 0 - 86400 DS3XM12.pmthresholds.line.nearend.1day.LOSS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.line.nearend.1day.SES 40 (seconds) 0 - 86400 DS3XM12.pmthresholds.pbitpath.nearend.15min.AISS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.pbitpath.nearend.15min.CV 382 (BIP count) 0 - 38700 DS3XM12.pmthresholds.pbitpath.nearend.15min.ES 25 (seconds) 0 - 900 DS3XM12.pmthresholds.pbitpath.nearend.15min.SAS 2 (seconds) 0 - 900 DS3XM12.pmthresholds.pbitpath.nearend.15min.SES 4 (seconds) 0 - 900 DS3XM12.pmthresholds.pbitpath.nearend.15min.UAS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.pbitpath.nearend.1day.AISS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.pbitpath.nearend.1day.CV 3820 (BIP count) 0 - 3715200 DS3XM12.pmthresholds.pbitpath.nearend.1day.ES 250 (seconds) 0 - 86400 DS3XM12.pmthresholds.pbitpath.nearend.1day.SAS 8 (seconds) 0 - 86400 DS3XM12.pmthresholds.pbitpath.nearend.1day.SES 40 (seconds) 0 - 86400 DS3XM12.pmthresholds.pbitpath.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.sts.farend.15min.CV 15 (B3 count) 0 - 2160000 DS3XM12.pmthresholds.sts.farend.15min.ES 12 (seconds) 0 - 900 DS3XM12.pmthresholds.sts.farend.15min.FC 10 (count) 0 - 72 DS3XM12.pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900 DS3XM12.pmthresholds.sts.farend.15min.UAS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.sts.farend.1day.CV 125 (B3 count) 0 - 207360000 DS3XM12.pmthresholds.sts.farend.1day.ES 100 (seconds) 0 - 86400 DS3XM12.pmthresholds.sts.farend.1day.FC 10 (count) 0 - 6912 DS3XM12.pmthresholds.sts.farend.1day.SES 7 (seconds) 0 - 86400 DS3XM12.pmthresholds.sts.farend.1day.UAS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.sts.nearend.15min.CV 15 (B3 count) 0 - 2160000 DS3XM12.pmthresholds.sts.nearend.15min.ES 12 (seconds) 0 - 900 DS3XM12.pmthresholds.sts.nearend.15min.FC 10 (count) 0 - 72 DS3XM12.pmthresholds.sts.nearend.15min.SES 3 (seconds) 0 - 900 DS3XM12.pmthresholds.sts.nearend.15min.UAS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.sts.nearend.1day.CV 125 (B3 count) 0 - 207360000 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-29 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-8 DS3XM-12 Card Default Settings (continued) Default Name Default Value Default Domain DS3XM12.pmthresholds.sts.nearend.1day.ES 100 (seconds) 0 - 86400 DS3XM12.pmthresholds.sts.nearend.1day.FC 10 (count) 0 - 6912 DS3XM12.pmthresholds.sts.nearend.1day.SES 7 (seconds) 0 - 86400 DS3XM12.pmthresholds.sts.nearend.1day.UAS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.vt.farend.15min.CV 15 (BIP8 count) 0 - 2160000 DS3XM12.pmthresholds.vt.farend.15min.ES 12 (seconds) 0 - 900 DS3XM12.pmthresholds.vt.farend.15min.SES 3 (seconds) 0 - 900 DS3XM12.pmthresholds.vt.farend.15min.UAS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.vt.farend.1day.CV 125 (BIP8 count) 0 - 207360000 DS3XM12.pmthresholds.vt.farend.1day.ES 100 (seconds) 0 - 86400 DS3XM12.pmthresholds.vt.farend.1day.SES 7 (seconds) 0 - 86400 DS3XM12.pmthresholds.vt.farend.1day.UAS 10 (seconds) 0 - 86400 DS3XM12.pmthresholds.vt.nearend.15min.CV 15 (BIP8 count) 0 - 2160000 DS3XM12.pmthresholds.vt.nearend.15min.ES 12 (seconds) 0 - 900 DS3XM12.pmthresholds.vt.nearend.15min.SES 3 (seconds) 0 - 900 DS3XM12.pmthresholds.vt.nearend.15min.UAS 10 (seconds) 0 - 900 DS3XM12.pmthresholds.vt.nearend.1day.CV 125 (BIP8 count) 0 - 207360000 DS3XM12.pmthresholds.vt.nearend.1day.ES 100 (seconds) 0 - 86400 DS3XM12.pmthresholds.vt.nearend.1day.SES 7 (seconds) 0 - 86400 DS3XM12.pmthresholds.vt.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.9 EC1-12 Card Default Settings Table C-9 lists the EC1-12 card default settings. Table C-9 EC1-12 Card Default Settings Default Name Default Value Default Domain EC1.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 EC1.config.line.LineLength 0 - 225 ft 0 - 225 ft, 226 - 450 ft EC1.config.line.PJStsMon# 0 (STS #) 0-1 EC1.config.line.RxEqualization TRUE TRUE, FALSE EC1.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 EC1.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE EC1.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 EC1.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS EC1.config.sts.IPPMEnabled FALSE TRUE, FALSE EC1.pmthresholds.line.farend.15min.CV 1312 (B2 count) 0 - 137700 Cisco ONS 15454 Reference Manual, R8.5.x C-30 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-9 EC1-12 Card Default Settings (continued) Default Name Default Value Default Domain EC1.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 EC1.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 EC1.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 EC1.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 EC1.pmthresholds.line.farend.1day.CV 13120 (B2 count) 0 - 8850600 EC1.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 EC1.pmthresholds.line.farend.1day.FC 40 (count) 0 - 72 EC1.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 EC1.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 EC1.pmthresholds.line.nearend.15min.CV 1312 (B2 count) 0 - 137700 EC1.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 EC1.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 EC1.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 EC1.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 EC1.pmthresholds.line.nearend.1day.CV 13120 (B2 count) 0 - 13219200 EC1.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 EC1.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 EC1.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 EC1.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 EC1.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 138600 EC1.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 EC1.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 EC1.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 EC1.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 13305600 EC1.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 EC1.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 EC1.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 EC1.pmthresholds.sts1.farend.15min.CV 15 (B3 count) 0 - 2160000 EC1.pmthresholds.sts1.farend.15min.ES 12 (seconds) 0 - 900 EC1.pmthresholds.sts1.farend.15min.FC 10 (count) 0 - 72 EC1.pmthresholds.sts1.farend.15min.SES 3 (seconds) 0 - 900 EC1.pmthresholds.sts1.farend.15min.UAS 10 (seconds) 0 - 900 EC1.pmthresholds.sts1.farend.1day.CV 125 (B3 count) 0 - 207360000 EC1.pmthresholds.sts1.farend.1day.ES 100 (seconds) 0 - 86400 EC1.pmthresholds.sts1.farend.1day.FC 10 (count) 0 - 6912 EC1.pmthresholds.sts1.farend.1day.SES 7 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-31 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-9 EC1-12 Card Default Settings (continued) Default Name Default Value Default Domain EC1.pmthresholds.sts1.farend.1day.UAS 10 (seconds) 0 - 86400 EC1.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 EC1.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 EC1.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 EC1.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 EC1.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 EC1.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 EC1.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 EC1.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 EC1.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 EC1.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 EC1.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 EC1.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 EC1.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 EC1.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 EC1.pmthresholds.sts1.nearend.1day.FC 10 (count) 0 - 6912 EC1.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 EC1.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 EC1.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 EC1.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 EC1.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 EC1.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 EC1.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 EC1.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 EC1.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.10 FC_MR-4 Card Default Settings Table C-10 lists the FC_MR-4 card default settings. Cisco ONS 15454 Reference Manual, R8.5.x C-32 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-10 FC_MR-4 Card Default Settings Default Name Default Value Default Domain FC-MR.config.card.Mode Fibre Fibre Channel Line Rate, Fibre Channel/FICO Channel/FICON Enhanced when N Enhanced //.port.MediaType Undefined; Fibre Channel/FICON Enhanced when //.port.MediaType FICON 1 Gbps ISL, FICON - 2 Gbps ISL; Fibre Channel Line Rate, Fibre Channel/FICON Enhanced when //.port.MediaType Fibre Channel 1 Gbps ISL, Fibre Channel - 2 Gbps ISL FC-MR.config.port.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 FC-MR.config.port.distanceExtension.AutoadjustGFPBufferThreshold TRUE TRUE, FALSE FC-MR.config.port.distanceExtension.AutoDetect TRUE TRUE, FALSE FC-MR.config.port.distanceExtension.NumCredits 32 2 - 256 FC-MR.config.port.distanceExtension.NumGFPBuffers 16 16, 32, 48 .. 1200 FC-MR.config.port.DistanceExtensionVsLinkRecovery Distance Extension Neither Distance Extension nor Link Recovery, Distance Extension, LinkRecovery when MediaType Undefined; Distance Extension when MediaType FICON - 1 Gbps ISL, FICON - 2 Gbps ISL; Neither Distance Extension nor Link Recovery, Distance Extension, LinkRecovery when MediaType Fibre Channel - 1 Gbps ISL, Fibre Channel - 2 Gbps ISL FC-MR.config.port.enhancedFibreChannelFicon.IngressIdleFiltering TRUE TRUE, FALSE FC-MR.config.port.enhancedFibreChannelFicon.MaxFrameSize 2148 2148, 2152, 2156, 2160, 2164, 2168, 2172 FC-MR.config.port.MediaType Undefined Fibre Channel - 1 Gbps ISL, Fibre Channel - 2 Gbps ISL, FICON - 1 Gbps ISL, FICON - 2 Gbps ISL, Undefined FC-MR.config.port.State OOS,DSBLD IS, OOS,DSBLD, OOS,MT, IS,AINS C.2.3.11 Ethernet Card Default Settings Table C-11 lists the G1000 (G1K-4), ML1000, ML100T, ML-100X-8, ML-MR-10, CE-1000-4, CE-100T-8, and CE-MR-10 card default settings. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-33 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-11 Ethernet Card Default Settings Default Name Default Value Default Domain CE-1000-4.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 CE-1000-4.config.State OOS,DSBLD IS, OOS,DSBLD, OOS,MT, IS,AINS CE-1000-4.etherPortConfig.AutoNegotiation TRUE TRUE, FALSE CE-1000-4.etherPortConfig.FlowControl Symmetric None, Symmetric, Pass Through CE-1000-4.etherPortConfig.MTU 10004 (bytes) 1548, 10004 CE-1000-4.posPortConfig.FramingType GFP-F HDLC, GFP-F CE-100T-8.config.AINSSoakTime 00:15 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 CE-100T-8.config.State OOS,DSBLD IS, OOS,DSBLD, OOS,MT, IS,AINS CE-100T-8.etherPortConfig.802-1Q-VlanCoS 7 (count) 0-7 CE-100T-8.etherPortConfig.IP-ToS 255 (count) 0 - 255 CE-MR.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 CE-MR.config.card.Mode MANUAL AUTOMATIC, MANUAL CE-MR.config.State OOS,DSBLD IS, OOS,DSBLD, OOS,MT, IS,AINS CE-MR.etherPortConfig.802-1Q-VlanCoS 7 (count) 0-7 CE-MR.etherPortConfig.IP-ToS 255 (count) 0 - 255 G1000.config.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 G1000.config.State OOS,DSBLD IS, OOS,DSBLD, OOS,MT, IS,AINS ML1000.config.card.Mode HDLC HDLC, GFP-F, RPR 802.17 ML1000.config.PreServiceAlarmSuppression FALSE TRUE, FALSE ML1000.config.SoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 ML1000.ios.consolePortAccess TRUE TRUE, FALSE ML1000.ios.radiusServerAccess FALSE TRUE, FALSE ML100T.config.card.Mode HDLC HDLC, GFP-F, RPR 802.17 ML100T.config.PreServiceAlarmSuppression FALSE TRUE, FALSE ML100T.config.SoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 ML100T.ios.consolePortAccess TRUE TRUE, FALSE ML100T.ios.radiusServerAccess FALSE TRUE, FALSE ML100X-8.config.card.Mode HDLC HDLC, GFP-F, RPR 802.17 ML100X-8.config.PreServiceAlarmSuppression FALSE TRUE, FALSE ML100X-8.config.SoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 ML100X-8.ios.consolePortAccess TRUE TRUE, FALSE ML100X-8.ios.radiusServerAccess FALSE TRUE, FALSE ML-MR.config.PreServiceAlarmSuppression FALSE TRUE, FALSE ML-MR.config.SoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 Cisco ONS 15454 Reference Manual, R8.5.x C-34 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card C.2.3.12 OC-3 Card Default Settings Table C-12 lists the OC-3 (OC3 IR 4/STM1 SH 1310) card default settings. Table C-12 OC-3 Card Default Settings Default Name Default Value Default Domain OC3.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 OC3.config.line.PJStsMon# 0 (STS #) 0-3 OC3.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 OC3.config.line.sdh.AdminSSMIn STU G811, STU, G812T, G812L, SETS, DUS OC3.config.line.sdh.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC3.config.line.sdh.SendDoNotUse FALSE FALSE, TRUE OC3.config.line.sdh.SyncMsgIn TRUE FALSE, TRUE OC3.config.line.SendAISOnFacilityLoopback FALSE TRUE, FALSE OC3.config.line.SendAISOnTerminalLoopback FALSE FALSE OC3.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 OC3.config.line.sonet.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessage Set Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessage Set Generation 2; PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessage Set N/A OC3.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC3.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE OC3.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE OC3.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS OC3.config.sts.IPPMEnabled FALSE TRUE, FALSE OC3.pmthresholds.line.farend.15min.CV 1312 (B2 count) 0 - 137700 OC3.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 OC3.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 OC3.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 OC3.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 OC3.pmthresholds.line.farend.1day.CV 13120 (B2 count) 0 - 13219200 OC3.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 OC3.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 OC3.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-35 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-12 OC-3 Card Default Settings (continued) Default Name Default Value Default Domain OC3.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 OC3.pmthresholds.line.nearend.15min.CV 1312 (B2 count) 0 - 137700 OC3.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 OC3.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 OC3.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 OC3.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 OC3.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 OC3.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 OC3.pmthresholds.line.nearend.1day.CV 13120 (B2 count) 0 - 13219200 OC3.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 OC3.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 OC3.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 OC3.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 OC3.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 OC3.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 OC3.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 138600 OC3.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 OC3.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 OC3.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 OC3.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 13305600 OC3.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 OC3.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 OC3.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 OC3.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 OC3.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 OC3.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 OC3.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC3.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC3.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC3.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC3.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC3.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC3.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC3.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 OC3.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 OC3.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 Cisco ONS 15454 Reference Manual, R8.5.x C-36 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-12 OC-3 Card Default Settings (continued) Default Name Default Value Default Domain OC3.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 OC3.pmthresholds.sts1.nearend.1day.FC 10 (count) 0 - 6912 OC3.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC3.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC3.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC3.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC3.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC3.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC3.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC3.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 OC3.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 OC3.pmthresholds.sts3c.nearend.15min.CV 25 (B3 count) 0 - 2160000 OC3.pmthresholds.sts3c.nearend.15min.ES 20 (seconds) 0 - 900 OC3.pmthresholds.sts3c.nearend.15min.FC 10 (count) 0 - 72 OC3.pmthresholds.sts3c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC3.pmthresholds.sts3c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC3.pmthresholds.sts3c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC3.pmthresholds.sts3c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC3.pmthresholds.sts3c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC3.pmthresholds.sts3c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC3.pmthresholds.sts3c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC3.pmthresholds.sts3c.nearend.15min.SES 3 (seconds) 0 - 900 OC3.pmthresholds.sts3c.nearend.15min.UAS 10 (seconds) 0 - 900 OC3.pmthresholds.sts3c.nearend.1day.CV 250 (B3 count) 0 - 207360000 OC3.pmthresholds.sts3c.nearend.1day.ES 200 (seconds) 0 - 86400 OC3.pmthresholds.sts3c.nearend.1day.FC 10 (count) 0 - 6912 OC3.pmthresholds.sts3c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC3.pmthresholds.sts3c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC3.pmthresholds.sts3c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC3.pmthresholds.sts3c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC3.pmthresholds.sts3c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC3.pmthresholds.sts3c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC3.pmthresholds.sts3c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC3.pmthresholds.sts3c.nearend.1day.SES 7 (seconds) 0 - 86400 OC3.pmthresholds.sts3c.nearend.1day.UAS 10 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-37 Appendix C Network Element Defaults C.2.3 Defaults by Card C.2.3.13 OC3-8 Card Default Settings Table C-13 lists the eight-port OC3-8 (OC3 IR/STM1 SH 1310-8) card default settings. Table C-13 OC3-8 Card Default Settings Default Name Default Value Default Domain OC3-8.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 OC3-8.config.line.AlsMode Disabled Disabled, Auto Restart, Manual Restart, Manual Restart for Test OC3-8.config.line.AlsRecoveryPulseDuration 2.0 (seconds) 2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test OC3-8.config.line.AlsRecoveryPulseInterval 100 (seconds) 60 - 300 OC3-8.config.line.PJStsMon# 0 (STS #) 0-3 OC3-8.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 OC3-8.config.line.sdh.AdminSSMIn STU G811, STU, G812T, G812L, SETS, DUS OC3-8.config.line.sdh.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC3-8.config.line.sdh.SendDoNotUse FALSE FALSE, TRUE OC3-8.config.line.sdh.SyncMsgIn TRUE FALSE, TRUE OC3-8.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE OC3-8.config.line.SendAISOnTerminalLoopback FALSE FALSE OC3-8.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 OC3-8.config.line.sonet.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessage Set Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessage Set Generation 2; PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessage Set N/A OC3-8.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC3-8.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE OC3-8.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE OC3-8.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS OC3-8.config.sts.IPPMEnabled FALSE TRUE, FALSE OC3-8.physicalthresholds.alarm.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 OC3-8.physicalthresholds.alarm.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH Cisco ONS 15454 Reference Manual, R8.5.x C-38 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-13 OC3-8 Card Default Settings (continued) Default Name Default Value Default Domain OC3-8.physicalthresholds.alarm.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 OC3-8.physicalthresholds.alarm.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH OC3-8.physicalthresholds.alarm.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 OC3-8.physicalthresholds.alarm.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH OC3-8.physicalthresholds.warning.15min.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 OC3-8.physicalthresholds.warning.15min.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH OC3-8.physicalthresholds.warning.15min.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 OC3-8.physicalthresholds.warning.15min.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH OC3-8.physicalthresholds.warning.15min.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 OC3-8.physicalthresholds.warning.15min.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH OC3-8.physicalthresholds.warning.1day.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 OC3-8.physicalthresholds.warning.1day.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH OC3-8.physicalthresholds.warning.1day.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 OC3-8.physicalthresholds.warning.1day.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH OC3-8.physicalthresholds.warning.1day.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 OC3-8.physicalthresholds.warning.1day.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH OC3-8.pmthresholds.line.farend.15min.CV 1312 (B2 count) 0 - 137700 OC3-8.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 OC3-8.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 OC3-8.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 OC3-8.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 OC3-8.pmthresholds.line.farend.1day.CV 13120 (B2 count) 0 - 13219200 OC3-8.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 OC3-8.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 OC3-8.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 OC3-8.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 OC3-8.pmthresholds.line.nearend.15min.CV 1312 (B2 count) 0 - 137700 OC3-8.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 OC3-8.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 OC3-8.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-39 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-13 OC3-8 Card Default Settings (continued) Default Name Default Value Default Domain OC3-8.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 OC3-8.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 OC3-8.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 OC3-8.pmthresholds.line.nearend.1day.CV 13120 (B2 count) 0 - 13219200 OC3-8.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 OC3-8.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 OC3-8.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 OC3-8.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 OC3-8.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 OC3-8.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 OC3-8.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 138600 OC3-8.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 OC3-8.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 OC3-8.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 OC3-8.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 13305600 OC3-8.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 OC3-8.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 OC3-8.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 OC3-8.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 OC3-8.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 OC3-8.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 OC3-8.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC3-8.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC3-8.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC3-8.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC3-8.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC3-8.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC3-8.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC3-8.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 OC3-8.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 OC3-8.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 OC3-8.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 OC3-8.pmthresholds.sts1.nearend.1day.FC 10 (count) 0 - 6912 OC3-8.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC3-8.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC3-8.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 Cisco ONS 15454 Reference Manual, R8.5.x C-40 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-13 OC3-8 Card Default Settings (continued) Default Name Default Value Default Domain OC3-8.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC3-8.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC3-8.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC3-8.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC3-8.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 OC3-8.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 OC3-8.pmthresholds.sts3c.nearend.15min.CV 25 (B3 count) 0 - 2160000 OC3-8.pmthresholds.sts3c.nearend.15min.ES 20 (seconds) 0 - 900 OC3-8.pmthresholds.sts3c.nearend.15min.FC 10 (count) 0 - 72 OC3-8.pmthresholds.sts3c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC3-8.pmthresholds.sts3c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC3-8.pmthresholds.sts3c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC3-8.pmthresholds.sts3c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC3-8.pmthresholds.sts3c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC3-8.pmthresholds.sts3c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC3-8.pmthresholds.sts3c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC3-8.pmthresholds.sts3c.nearend.15min.SES 3 (seconds) 0 - 900 OC3-8.pmthresholds.sts3c.nearend.15min.UAS 10 (seconds) 0 - 900 OC3-8.pmthresholds.sts3c.nearend.1day.CV 250 (B3 count) 0 - 207360000 OC3-8.pmthresholds.sts3c.nearend.1day.ES 200 (seconds) 0 - 86400 OC3-8.pmthresholds.sts3c.nearend.1day.FC 10 (count) 0 - 6912 OC3-8.pmthresholds.sts3c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC3-8.pmthresholds.sts3c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC3-8.pmthresholds.sts3c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC3-8.pmthresholds.sts3c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 691200000 OC3-8.pmthresholds.sts3c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC3-8.pmthresholds.sts3c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC3-8.pmthresholds.sts3c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC3-8.pmthresholds.sts3c.nearend.1day.SES 7 (seconds) 0 - 86400 OC3-8.pmthresholds.sts3c.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.14 OC-12 Card Default Settings Table C-14 lists the OC-12 (OC12 IR/STM4 SH 1310, OC12 LR/STM4 LH 1310, and OC12 LR/STM4 LH 1550) card default settings. Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-41 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-14 OC-12 Card Default Settings Default Name Default Value Default Domain OC12.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 OC12.config.line.PJStsMon# 0 (STS #) 0 - 12 OC12.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 OC12.config.line.sdh.AdminSSMIn STU G811, STU, G812T, G812L, SETS, DUS OC12.config.line.sdh.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC12.config.line.sdh.SendDoNotUse FALSE FALSE, TRUE OC12.config.line.sdh.SyncMsgIn TRUE FALSE, TRUE OC12.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 OC12.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE OC12.config.line.SendAISOnTerminalLoopback FALSE FALSE OC12.config.line.sonet.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessag eSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessag eSet Generation 2; PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMessag eSet N/A OC12.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC12.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE OC12.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE OC12.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS OC12.config.sts.IPPMEnabled FALSE TRUE, FALSE OC12.pmthresholds.line.farend.15min.CV 5315 (B2 count) 0 - 552600 OC12.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 OC12.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 OC12.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 OC12.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 OC12.pmthresholds.line.farend.1day.CV 53150 (B2 count) 0 - 53049600 OC12.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 OC12.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 OC12.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x C-42 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-14 OC-12 Card Default Settings (continued) Default Name Default Value Default Domain OC12.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 OC12.pmthresholds.line.nearend.15min.CV 5315 (B2 count) 0 - 552600 OC12.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 OC12.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 OC12.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 OC12.pmthresholds.line.nearend.15min.PSC-W 1 (count) 0 - 600 OC12.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 OC12.pmthresholds.line.nearend.15min.PSD-W 300 (seconds) 0 - 900 OC12.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 OC12.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 OC12.pmthresholds.line.nearend.1day.CV 53150 (B2 count) 0 - 53049600 OC12.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 OC12.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 OC12.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 OC12.pmthresholds.line.nearend.1day.PSC-W 5 (count) 0 - 57600 OC12.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 OC12.pmthresholds.line.nearend.1day.PSD-W 600 (seconds) 0 - 86400 OC12.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 OC12.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 OC12.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 553500 OC12.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 OC12.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 OC12.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 OC12.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 53136000 OC12.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 OC12.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 OC12.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 OC12.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 OC12.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 OC12.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 OC12.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC12.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC12.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC12.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC12.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-43 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-14 OC-12 Card Default Settings (continued) Default Name Default Value Default Domain OC12.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC12.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC12.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 OC12.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 OC12.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 OC12.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 OC12.pmthresholds.sts1.nearend.1day.FC 10 (count) 0 - 6912 OC12.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC12.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC12.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC12.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC12.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC12.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC12.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC12.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 OC12.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 OC12.pmthresholds.sts12c.nearend.15min.CV 75 (B3 count) 0 - 2160000 OC12.pmthresholds.sts12c.nearend.15min.ES 60 (seconds) 0 - 900 OC12.pmthresholds.sts12c.nearend.15min.FC 10 (count) 0 - 72 OC12.pmthresholds.sts12c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC12.pmthresholds.sts12c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC12.pmthresholds.sts12c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC12.pmthresholds.sts12c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC12.pmthresholds.sts12c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC12.pmthresholds.sts12c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC12.pmthresholds.sts12c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC12.pmthresholds.sts12c.nearend.15min.SES 3 (seconds) 0 - 900 OC12.pmthresholds.sts12c.nearend.15min.UAS 10 (seconds) 0 - 900 OC12.pmthresholds.sts12c.nearend.1day.CV 750 (B3 count) 0 - 207360000 OC12.pmthresholds.sts12c.nearend.1day.ES 600 (seconds) 0 - 86400 OC12.pmthresholds.sts12c.nearend.1day.FC 10 (count) 0 - 6912 OC12.pmthresholds.sts12c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC12.pmthresholds.sts12c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC12.pmthresholds.sts12c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC12.pmthresholds.sts12c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC12.pmthresholds.sts12c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x C-44 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-14 OC-12 Card Default Settings (continued) Default Name Default Value Default Domain OC12.pmthresholds.sts12c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC12.pmthresholds.sts12c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC12.pmthresholds.sts12c.nearend.1day.SES 7 (seconds) 0 - 86400 OC12.pmthresholds.sts12c.nearend.1day.UAS 10 (seconds) 0 - 86400 OC12.pmthresholds.sts3c-9c.nearend.15min.CV 25 (B3 count) 0 - 2160000 OC12.pmthresholds.sts3c-9c.nearend.15min.ES 20 (seconds) 0 - 900 OC12.pmthresholds.sts3c-9c.nearend.15min.FC 10 (count) 0 - 72 OC12.pmthresholds.sts3c-9c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC12.pmthresholds.sts3c-9c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC12.pmthresholds.sts3c-9c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC12.pmthresholds.sts3c-9c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC12.pmthresholds.sts3c-9c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC12.pmthresholds.sts3c-9c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC12.pmthresholds.sts3c-9c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC12.pmthresholds.sts3c-9c.nearend.15min.SES 3 (seconds) 0 - 900 OC12.pmthresholds.sts3c-9c.nearend.15min.UAS 10 (seconds) 0 - 900 OC12.pmthresholds.sts3c-9c.nearend.1day.CV 250 (B3 count) 0 - 207360000 OC12.pmthresholds.sts3c-9c.nearend.1day.ES 200 (seconds) 0 - 86400 OC12.pmthresholds.sts3c-9c.nearend.1day.FC 10 (count) 0 - 6912 OC12.pmthresholds.sts3c-9c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC12.pmthresholds.sts3c-9c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC12.pmthresholds.sts3c-9c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC12.pmthresholds.sts3c-9c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC12.pmthresholds.sts3c-9c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC12.pmthresholds.sts3c-9c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC12.pmthresholds.sts3c-9c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC12.pmthresholds.sts3c-9c.nearend.1day.SES 7 (seconds) 0 - 86400 OC12.pmthresholds.sts3c-9c.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.15 OC12-4 Card Default Settings Table C-15 lists the four-port OC12-4 (OC12 IR/STM4 SH 1310-4) card default settings. Table C-15 OC12-4 Card Default Settings Default Name Default Value Default Domain OC12-4.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 OC12-4.config.line.PJStsMon# 0 (STS #) 0 - 12 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-45 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-15 OC12-4 Card Default Settings (continued) Default Name Default Value Default Domain OC12-4.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 OC12-4.config.line.sdh.AdminSSMIn STU G811, STU, G812T, G812L, SETS, DUS OC12-4.config.line.sdh.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC12-4.config.line.sdh.SendDoNotUse FALSE FALSE, TRUE OC12-4.config.line.sdh.SyncMsgIn TRUE FALSE, TRUE OC12-4.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE OC12-4.config.line.SendAISOnTerminalLoopback FALSE FALSE OC12-4.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 OC12-4.config.line.sonet.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMe ssageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMe ssageSet Generation 2; PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMe ssageSet N/A OC12-4.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC12-4.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE OC12-4.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE OC12-4.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS OC12-4.config.sts.IPPMEnabled FALSE TRUE, FALSE OC12-4.pmthresholds.line.farend.15min.CV 5315 (B2 count) 0 - 552600 OC12-4.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 OC12-4.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 OC12-4.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 OC12-4.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 OC12-4.pmthresholds.line.farend.1day.CV 53150 (B2 count) 0 - 53049600 OC12-4.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 OC12-4.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 OC12-4.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 OC12-4.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 OC12-4.pmthresholds.line.nearend.15min.CV 5315 (B2 count) 0 - 552600 Cisco ONS 15454 Reference Manual, R8.5.x C-46 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-15 OC12-4 Card Default Settings (continued) Default Name Default Value Default Domain OC12-4.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 OC12-4.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 OC12-4.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 OC12-4.pmthresholds.line.nearend.15min.PSC-W 1 (count) 0 - 600 OC12-4.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 OC12-4.pmthresholds.line.nearend.15min.PSD-W 300 (seconds) 0 - 900 OC12-4.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 OC12-4.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 OC12-4.pmthresholds.line.nearend.1day.CV 53150 (B2 count) 0 - 53049600 OC12-4.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 OC12-4.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 OC12-4.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 OC12-4.pmthresholds.line.nearend.1day.PSC-W 5 (count) 0 - 57600 OC12-4.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 OC12-4.pmthresholds.line.nearend.1day.PSD-W 600 (seconds) 0 - 86400 OC12-4.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 OC12-4.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 OC12-4.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 553500 OC12-4.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 OC12-4.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 OC12-4.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 OC12-4.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 53136000 OC12-4.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 OC12-4.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 OC12-4.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 OC12-4.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 OC12-4.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 OC12-4.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 OC12-4.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC12-4.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC12-4.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC12-4.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-47 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-15 OC12-4 Card Default Settings (continued) Default Name Default Value Default Domain OC12-4.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 OC12-4.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 OC12-4.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 OC12-4.pmthresholds.sts1.nearend.1day.FC 10 (count) 0 - 6912 OC12-4.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC12-4.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC12-4.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC12-4.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 OC12-4.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 OC12-4.pmthresholds.sts12c.nearend.15min.CV 75 (B3 count) 0 - 2160000 OC12-4.pmthresholds.sts12c.nearend.15min.ES 60 (seconds) 0 - 900 OC12-4.pmthresholds.sts12c.nearend.15min.FC 10 (count) 0 - 72 OC12-4.pmthresholds.sts12c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts12c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts12c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC12-4.pmthresholds.sts12c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC12-4.pmthresholds.sts12c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC12-4.pmthresholds.sts12c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts12c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts12c.nearend.15min.SES 3 (seconds) 0 - 900 OC12-4.pmthresholds.sts12c.nearend.15min.UAS 10 (seconds) 0 - 900 OC12-4.pmthresholds.sts12c.nearend.1day.CV 750 (B3 count) 0 - 207360000 OC12-4.pmthresholds.sts12c.nearend.1day.ES 600 (seconds) 0 - 86400 OC12-4.pmthresholds.sts12c.nearend.1day.FC 10 (count) 0 - 6912 OC12-4.pmthresholds.sts12c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts12c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts12c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC12-4.pmthresholds.sts12c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC12-4.pmthresholds.sts12c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC12-4.pmthresholds.sts12c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts12c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts12c.nearend.1day.SES 7 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x C-48 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-15 OC12-4 Card Default Settings (continued) Default Name Default Value Default Domain OC12-4.pmthresholds.sts12c.nearend.1day.UAS 10 (seconds) 0 - 86400 OC12-4.pmthresholds.sts3c-9c.nearend.15min.CV 25 (B3 count) 0 - 2160000 OC12-4.pmthresholds.sts3c-9c.nearend.15min.ES 20 (seconds) 0 - 900 OC12-4.pmthresholds.sts3c-9c.nearend.15min.FC 10 (count) 0 - 72 OC12-4.pmthresholds.sts3c-9c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts3c-9c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts3c-9c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC12-4.pmthresholds.sts3c-9c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC12-4.pmthresholds.sts3c-9c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC12-4.pmthresholds.sts3c-9c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts3c-9c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC12-4.pmthresholds.sts3c-9c.nearend.15min.SES 3 (seconds) 0 - 900 OC12-4.pmthresholds.sts3c-9c.nearend.15min.UAS 10 (seconds) 0 - 900 OC12-4.pmthresholds.sts3c-9c.nearend.1day.CV 250 (B3 count) 0 - 207360000 OC12-4.pmthresholds.sts3c-9c.nearend.1day.ES 200 (seconds) 0 - 86400 OC12-4.pmthresholds.sts3c-9c.nearend.1day.FC 10 (count) 0 - 6912 OC12-4.pmthresholds.sts3c-9c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts3c-9c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts3c-9c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC12-4.pmthresholds.sts3c-9c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC12-4.pmthresholds.sts3c-9c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC12-4.pmthresholds.sts3c-9c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts3c-9c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC12-4.pmthresholds.sts3c-9c.nearend.1day.SES 7 (seconds) 0 - 86400 OC12-4.pmthresholds.sts3c-9c.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.16 OC-48 Card Default Settings Table C-16 lists the OC-48 (OC48 IR 1310, OC48 LR 1550, OC48 IR/STM16 SH AS 1310, OC48 LR/STM16 LH AS 1550, OC48 ELR/STM16 EH 100 GHz, and OC48 ELR 200 GHz) card default settings. Table C-16 OC-48 Card Default Settings Default Name Default Value Default Domain OC48.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 OC48.config.line.AlsMode Disabled Disabled, Auto Restart, Manual Restart, Manual Restart for Test Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-49 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-16 OC-48 Card Default Settings (continued) Default Name Default Value Default Domain OC48.config.line.AlsRecoveryPulseDuration 2.0 (seconds) 2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test OC48.config.line.AlsRecoveryPulseInterval 100 (seconds) 60 - 300 OC48.config.line.PJStsMon# 0 (STS #) 0 - 48 OC48.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 OC48.config.line.sdh.AdminSSMIn STU G811, STU, G812T, G812L, SETS, DUS OC48.config.line.sdh.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC48.config.line.sdh.SendDoNotUse FALSE FALSE, TRUE OC48.config.line.sdh.SyncMsgIn TRUE FALSE, TRUE OC48.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE OC48.config.line.SendAISOnTerminalLoopback FALSE FALSE OC48.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 OC48.config.line.sonet.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMe ssageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMe ssageSet Generation 2; PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSMMe ssageSet N/A OC48.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC48.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE OC48.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE OC48.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS OC48.config.sts.IPPMEnabled FALSE TRUE, FALSE OC48.pmthresholds.line.farend.15min.CV 21260 (B2 count) 0 - 2212200 OC48.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 OC48.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 OC48.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 OC48.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 OC48.pmthresholds.line.farend.1day.CV 212600 (B2 count) 0 - 212371200 Cisco ONS 15454 Reference Manual, R8.5.x C-50 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-16 OC-48 Card Default Settings (continued) Default Name Default Value Default Domain OC48.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 OC48.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 OC48.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 OC48.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 OC48.pmthresholds.line.nearend.15min.CV 21260 (B2 count) 0 - 2212200 OC48.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 OC48.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 OC48.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 OC48.pmthresholds.line.nearend.15min.PSC-R 1 (count) 0 - 600 OC48.pmthresholds.line.nearend.15min.PSC-S 1 (count) 0 - 600 OC48.pmthresholds.line.nearend.15min.PSC-W 1 (count) 0 - 600 OC48.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 OC48.pmthresholds.line.nearend.15min.PSD-R 300 (seconds) 0 - 900 OC48.pmthresholds.line.nearend.15min.PSD-S 300 (seconds) 0 - 900 OC48.pmthresholds.line.nearend.15min.PSD-W 300 (seconds) 0 - 900 OC48.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 OC48.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 OC48.pmthresholds.line.nearend.1day.CV 212600 (B2 count) 0 - 212371200 OC48.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 OC48.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 OC48.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 OC48.pmthresholds.line.nearend.1day.PSC-R 5 (count) 0 - 57600 OC48.pmthresholds.line.nearend.1day.PSC-S 5 (count) 0 - 57600 OC48.pmthresholds.line.nearend.1day.PSC-W 5 (count) 0 - 57600 OC48.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 OC48.pmthresholds.line.nearend.1day.PSD-R 600 (seconds) 0 - 86400 OC48.pmthresholds.line.nearend.1day.PSD-S 600 (seconds) 0 - 86400 OC48.pmthresholds.line.nearend.1day.PSD-W 600 (seconds) 0 - 86400 OC48.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 OC48.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 OC48.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 2151900 OC48.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 OC48.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 OC48.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 OC48.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 206582400 OC48.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-51 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-16 OC-48 Card Default Settings (continued) Default Name Default Value Default Domain OC48.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 OC48.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 OC48.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 OC48.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 OC48.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 OC48.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC48.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC48.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC48.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC48.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC48.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC48.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC48.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 OC48.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 OC48.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 OC48.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 OC48.pmthresholds.sts1.nearend.1day.FC 10 (count) 0 - 6912 OC48.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC48.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC48.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC48.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC48.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC48.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC48.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC48.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 OC48.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 OC48.pmthresholds.sts12c-48c.nearend.15min.CV 75 (B3 count) 0 - 2160000 OC48.pmthresholds.sts12c-48c.nearend.15min.ES 60 (seconds) 0 - 900 OC48.pmthresholds.sts12c-48c.nearend.15min.FC 10 (count) 0 - 72 OC48.pmthresholds.sts12c-48c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC48.pmthresholds.sts12c-48c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC48.pmthresholds.sts12c-48c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC48.pmthresholds.sts12c-48c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC48.pmthresholds.sts12c-48c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC48.pmthresholds.sts12c-48c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC48.pmthresholds.sts12c-48c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 Cisco ONS 15454 Reference Manual, R8.5.x C-52 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-16 OC-48 Card Default Settings (continued) Default Name Default Value Default Domain OC48.pmthresholds.sts12c-48c.nearend.15min.SES 3 (seconds) 0 - 900 OC48.pmthresholds.sts12c-48c.nearend.15min.UAS 10 (seconds) 0 - 900 OC48.pmthresholds.sts12c-48c.nearend.1day.CV 750 (B3 count) 0 - 207360000 OC48.pmthresholds.sts12c-48c.nearend.1day.ES 600 (seconds) 0 - 86400 OC48.pmthresholds.sts12c-48c.nearend.1day.FC 10 (count) 0 - 6912 OC48.pmthresholds.sts12c-48c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC48.pmthresholds.sts12c-48c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC48.pmthresholds.sts12c-48c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC48.pmthresholds.sts12c-48c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC48.pmthresholds.sts12c-48c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC48.pmthresholds.sts12c-48c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC48.pmthresholds.sts12c-48c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC48.pmthresholds.sts12c-48c.nearend.1day.SES 7 (seconds) 0 - 86400 OC48.pmthresholds.sts12c-48c.nearend.1day.UAS 10 (seconds) 0 - 86400 OC48.pmthresholds.sts3c-9c.nearend.15min.CV 25 (B3 count) 0 - 2160000 OC48.pmthresholds.sts3c-9c.nearend.15min.ES 20 (seconds) 0 - 900 OC48.pmthresholds.sts3c-9c.nearend.15min.FC 10 (count) 0 - 72 OC48.pmthresholds.sts3c-9c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC48.pmthresholds.sts3c-9c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC48.pmthresholds.sts3c-9c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC48.pmthresholds.sts3c-9c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC48.pmthresholds.sts3c-9c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC48.pmthresholds.sts3c-9c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC48.pmthresholds.sts3c-9c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC48.pmthresholds.sts3c-9c.nearend.15min.SES 3 (seconds) 0 - 900 OC48.pmthresholds.sts3c-9c.nearend.15min.UAS 10 (seconds) 0 - 900 OC48.pmthresholds.sts3c-9c.nearend.1day.CV 250 (B3 count) 0 - 207360000 OC48.pmthresholds.sts3c-9c.nearend.1day.ES 200 (seconds) 0 - 86400 OC48.pmthresholds.sts3c-9c.nearend.1day.FC 10 (count) 0 - 6912 OC48.pmthresholds.sts3c-9c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC48.pmthresholds.sts3c-9c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC48.pmthresholds.sts3c-9c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC48.pmthresholds.sts3c-9c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC48.pmthresholds.sts3c-9c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC48.pmthresholds.sts3c-9c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC48.pmthresholds.sts3c-9c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-53 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-16 OC-48 Card Default Settings (continued) Default Name Default Value Default Domain OC48.pmthresholds.sts3c-9c.nearend.1day.SES 7 (seconds) 0 - 86400 OC48.pmthresholds.sts3c-9c.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.17 OC-192 Card Default Settings Table C-17 lists the OC-192 (OC192 SR/STM64 IO 1310, OC192 LR/STM64 LH ITU 15xx.xx, OC192 IR/STM64 SH 1550, and OC192 LR/STM64 LH 1550) card default settings. Table C-17 OC-192 Card Default Settings Default Name Default Value Default Domain OC192.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 OC192.config.line.AlsMode Disabled Disabled, Auto Restart, Manual Restart, Manual Restart for Test OC192.config.line.AlsRecoveryPulseDuration 2.0 (seconds) 2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test OC192.config.line.AlsRecoveryPulseInterval 100 (seconds) 60 - 300 OC192.config.line.PJStsMon# 0 (STS #) 0 - 192 OC192.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 OC192.config.line.sdh.AdminSSMIn STU G811, STU, G812T, G812L, SETS, DUS OC192.config.line.sdh.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC192.config.line.sdh.SendDoNotUse FALSE FALSE, TRUE OC192.config.line.sdh.SyncMsgIn TRUE FALSE, TRUE OC192.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE OC192.config.line.SendAISOnTerminalLoopback FALSE FALSE OC192.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 Cisco ONS 15454 Reference Manual, R8.5.x C-54 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-17 OC-192 Card Default Settings (continued) Default Name Default Value Default Domain OC192.config.line.sonet.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSM MessageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSM MessageSet Generation 2; PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SSM MessageSet N/A OC192.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC192.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE OC192.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE OC192.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS OC192.config.sts.IPPMEnabled FALSE TRUE, FALSE OC192.physicalthresholds.alarm.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 OC192.physicalthresholds.alarm.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH OC192.physicalthresholds.alarm.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 OC192.physicalthresholds.alarm.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH OC192.physicalthresholds.alarm.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 OC192.physicalthresholds.alarm.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH OC192.physicalthresholds.warning.15min.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 OC192.physicalthresholds.warning.15min.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH OC192.physicalthresholds.warning.15min.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 OC192.physicalthresholds.warning.15min.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH OC192.physicalthresholds.warning.15min.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 OC192.physicalthresholds.warning.15min.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH OC192.physicalthresholds.warning.1day.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 OC192.physicalthresholds.warning.1day.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH OC192.physicalthresholds.warning.1day.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-55 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-17 OC-192 Card Default Settings (continued) Default Name Default Value Default Domain OC192.physicalthresholds.warning.1day.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH OC192.physicalthresholds.warning.1day.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 OC192.physicalthresholds.warning.1day.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH OC192.pmthresholds.line.farend.15min.CV 85040 (B2 count) 0 - 8850600 OC192.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 OC192.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 OC192.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 OC192.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 OC192.pmthresholds.line.farend.1day.CV 850400 (B2 count) 0 - 849657600 OC192.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 OC192.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 OC192.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 OC192.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 OC192.pmthresholds.line.nearend.15min.CV 85040 (B2 count) 0 - 8850600 OC192.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 OC192.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 OC192.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 OC192.pmthresholds.line.nearend.15min.PSC-R 1 (count) 0 - 600 OC192.pmthresholds.line.nearend.15min.PSC-S 1 (count) 0 - 600 OC192.pmthresholds.line.nearend.15min.PSC-W 1 (count) 0 - 600 OC192.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 OC192.pmthresholds.line.nearend.15min.PSD-R 300 (seconds) 0 - 900 OC192.pmthresholds.line.nearend.15min.PSD-S 300 (seconds) 0 - 900 OC192.pmthresholds.line.nearend.15min.PSD-W 300 (seconds) 0 - 900 OC192.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 OC192.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 OC192.pmthresholds.line.nearend.1day.CV 850400 (B2 count) 0 - 849657600 OC192.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 OC192.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 OC192.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 OC192.pmthresholds.line.nearend.1day.PSC-R 5 (count) 0 - 57600 OC192.pmthresholds.line.nearend.1day.PSC-S 5 (count) 0 - 57600 OC192.pmthresholds.line.nearend.1day.PSC-W 5 (count) 0 - 57600 OC192.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x C-56 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-17 OC-192 Card Default Settings (continued) Default Name Default Value Default Domain OC192.pmthresholds.line.nearend.1day.PSD-R 600 (seconds) 0 - 86400 OC192.pmthresholds.line.nearend.1day.PSD-S 600 (seconds) 0 - 86400 OC192.pmthresholds.line.nearend.1day.PSD-W 600 (seconds) 0 - 86400 OC192.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 OC192.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 OC192.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 7967700 OC192.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 OC192.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 OC192.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 OC192.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 764899200 OC192.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 OC192.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 OC192.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 OC192.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 OC192.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 OC192.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 OC192.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC192.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC192.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC192.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC192.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC192.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC192.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC192.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 OC192.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 OC192.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 OC192.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 OC192.pmthresholds.sts1.nearend.1day.FC 10 (count) 0 - 6912 OC192.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC192.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC192.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC192.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC192.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC192.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC192.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-57 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-17 OC-192 Card Default Settings (continued) Default Name Default Value Default Domain OC192.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 OC192.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 OC192.pmthresholds.sts12c-192c.nearend.15min.CV 75 (B3 count) 0 - 2160000 OC192.pmthresholds.sts12c-192c.nearend.15min.ES 60 (seconds) 0 - 900 OC192.pmthresholds.sts12c-192c.nearend.15min.FC 10 (count) 0 - 72 OC192.pmthresholds.sts12c-192c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC192.pmthresholds.sts12c-192c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC192.pmthresholds.sts12c-192c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC192.pmthresholds.sts12c-192c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC192.pmthresholds.sts12c-192c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC192.pmthresholds.sts12c-192c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC192.pmthresholds.sts12c-192c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC192.pmthresholds.sts12c-192c.nearend.15min.SES 3 (seconds) 0 - 900 OC192.pmthresholds.sts12c-192c.nearend.15min.UAS 10 (seconds) 0 - 900 OC192.pmthresholds.sts12c-192c.nearend.1day.CV 750 (B3 count) 0 - 207360000 OC192.pmthresholds.sts12c-192c.nearend.1day.ES 600 (seconds) 0 - 86400 OC192.pmthresholds.sts12c-192c.nearend.1day.FC 10 (count) 0 - 6912 OC192.pmthresholds.sts12c-192c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC192.pmthresholds.sts12c-192c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC192.pmthresholds.sts12c-192c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC192.pmthresholds.sts12c-192c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 691200000 OC192.pmthresholds.sts12c-192c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC192.pmthresholds.sts12c-192c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC192.pmthresholds.sts12c-192c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC192.pmthresholds.sts12c-192c.nearend.1day.SES 7 (seconds) 0 - 86400 OC192.pmthresholds.sts12c-192c.nearend.1day.UAS 10 (seconds) 0 - 86400 OC192.pmthresholds.sts3c-9c.nearend.15min.CV 25 (B3 count) 0 - 2160000 OC192.pmthresholds.sts3c-9c.nearend.15min.ES 20 (seconds) 0 - 900 OC192.pmthresholds.sts3c-9c.nearend.15min.FC 10 (count) 0 - 72 OC192.pmthresholds.sts3c-9c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC192.pmthresholds.sts3c-9c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC192.pmthresholds.sts3c-9c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC192.pmthresholds.sts3c-9c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC192.pmthresholds.sts3c-9c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC192.pmthresholds.sts3c-9c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC192.pmthresholds.sts3c-9c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 Cisco ONS 15454 Reference Manual, R8.5.x C-58 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-17 OC-192 Card Default Settings (continued) Default Name Default Value Default Domain OC192.pmthresholds.sts3c-9c.nearend.15min.SES 3 (seconds) 0 - 900 OC192.pmthresholds.sts3c-9c.nearend.15min.UAS 10 (seconds) 0 - 900 OC192.pmthresholds.sts3c-9c.nearend.1day.CV 250 (B3 count) 0 - 207360000 OC192.pmthresholds.sts3c-9c.nearend.1day.ES 200 (seconds) 0 - 86400 OC192.pmthresholds.sts3c-9c.nearend.1day.FC 10 (count) 0 - 6912 OC192.pmthresholds.sts3c-9c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC192.pmthresholds.sts3c-9c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC192.pmthresholds.sts3c-9c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC192.pmthresholds.sts3c-9c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC192.pmthresholds.sts3c-9c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC192.pmthresholds.sts3c-9c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC192.pmthresholds.sts3c-9c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC192.pmthresholds.sts3c-9c.nearend.1day.SES 7 (seconds) 0 - 86400 OC192.pmthresholds.sts3c-9c.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.18 OC192-XFP Default Settings Table C-18 lists the OC192-XFP default settings. Table C-18 OC192-XFP Default Settings Default Name Default Value Default Domain OC192-XFP.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 OC192-XFP.config.line.AlsMode Disabled Disabled, Auto Restart, Manual Restart, Manual Restart for Test OC192-XFP.config.line.AlsRecoveryPulseDuration 2.0 (seconds) 2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test OC192-XFP.config.line.AlsRecoveryPulseInterval 100 (seconds) 60 - 300 OC192-XFP.config.line.PJStsMon# 0 (STS #) 0 - 192 OC192-XFP.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 OC192-XFP.config.line.sdh.AdminSSMIn STU G811, STU, G812T, G812L, SETS, DUS OC192-XFP.config.line.sdh.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC192-XFP.config.line.sdh.SendDoNotUse FALSE FALSE, TRUE Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-59 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-18 OC192-XFP Default Settings (continued) Default Name Default Value Default Domain OC192-XFP.config.line.sdh.SyncMsgIn TRUE FALSE, TRUE OC192-XFP.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE OC192-XFP.config.line.SendAISOnTerminalLoopback TRUE TRUE, FALSE OC192-XFP.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 OC192-XFP.config.line.sonet.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SS MMessageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SS MMessageSet Generation 2; PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.//.//.//.NODE.timing.general.SS MMessageSet N/A OC192-XFP.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE OC192-XFP.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE OC192-XFP.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE OC192-XFP.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS OC192-XFP.config.sts.IPPMEnabled FALSE TRUE, FALSE OC192-XFP.physicalthresholds.alarm.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 OC192-XFP.physicalthresholds.alarm.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH OC192-XFP.physicalthresholds.alarm.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 OC192-XFP.physicalthresholds.alarm.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH OC192-XFP.physicalthresholds.alarm.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 OC192-XFP.physicalthresholds.alarm.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH OC192-XFP.physicalthresholds.warning.15min.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 OC192-XFP.physicalthresholds.warning.15min.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH OC192-XFP.physicalthresholds.warning.15min.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 OC192-XFP.physicalthresholds.warning.15min.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH OC192-XFP.physicalthresholds.warning.15min.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 OC192-XFP.physicalthresholds.warning.15min.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH Cisco ONS 15454 Reference Manual, R8.5.x C-60 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-18 OC192-XFP Default Settings (continued) Default Name Default Value Default Domain OC192-XFP.physicalthresholds.warning.1day.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 OC192-XFP.physicalthresholds.warning.1day.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH OC192-XFP.physicalthresholds.warning.1day.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 OC192-XFP.physicalthresholds.warning.1day.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH OC192-XFP.physicalthresholds.warning.1day.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 OC192-XFP.physicalthresholds.warning.1day.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH OC192-XFP.pmthresholds.line.farend.15min.CV 85040 (B2 count) 0 - 8850600 OC192-XFP.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 OC192-XFP.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 OC192-XFP.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 OC192-XFP.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 OC192-XFP.pmthresholds.line.farend.1day.CV 850400 (B2 count) 0 - 849657600 OC192-XFP.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 OC192-XFP.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 OC192-XFP.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 OC192-XFP.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 OC192-XFP.pmthresholds.line.nearend.15min.CV 85040 (B2 count) 0 - 8850600 OC192-XFP.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 OC192-XFP.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 OC192-XFP.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 OC192-XFP.pmthresholds.line.nearend.15min.PSC-R 1 (count) 0 - 600 OC192-XFP.pmthresholds.line.nearend.15min.PSC-S 1 (count) 0 - 600 OC192-XFP.pmthresholds.line.nearend.15min.PSC-W 1 (count) 0 - 600 OC192-XFP.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 OC192-XFP.pmthresholds.line.nearend.15min.PSD-R 300 (seconds) 0 - 900 OC192-XFP.pmthresholds.line.nearend.15min.PSD-S 300 (seconds) 0 - 900 OC192-XFP.pmthresholds.line.nearend.15min.PSD-W 300 (seconds) 0 - 900 OC192-XFP.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 OC192-XFP.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 OC192-XFP.pmthresholds.line.nearend.1day.CV 850400 (B2 count) 0 - 849657600 OC192-XFP.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-61 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-18 OC192-XFP Default Settings (continued) Default Name Default Value Default Domain OC192-XFP.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 OC192-XFP.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 OC192-XFP.pmthresholds.line.nearend.1day.PSC-R 5 (count) 0 - 57600 OC192-XFP.pmthresholds.line.nearend.1day.PSC-S 5 (count) 0 - 57600 OC192-XFP.pmthresholds.line.nearend.1day.PSC-W 5 (count) 0 - 57600 OC192-XFP.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.line.nearend.1day.PSD-R 600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.line.nearend.1day.PSD-S 600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.line.nearend.1day.PSD-W 600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 OC192-XFP.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 OC192-XFP.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 7967700 OC192-XFP.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 OC192-XFP.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 OC192-XFP.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 OC192-XFP.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 764899200 OC192-XFP.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 OC192-XFP.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 OC192-XFP.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts1.farend.15min.CV 15 (B3 count) 0 - 2160000 OC192-XFP.pmthresholds.sts1.farend.15min.ES 12 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts1.farend.15min.FC 10 (count) 0 - 72 OC192-XFP.pmthresholds.sts1.farend.15min.SES 3 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts1.farend.15min.UAS 10 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts1.farend.1day.CV 125 (B3 count) 0 - 207360000 OC192-XFP.pmthresholds.sts1.farend.1day.ES 100 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts1.farend.1day.FC 40 (count) 0 - 6912 OC192-XFP.pmthresholds.sts1.farend.1day.SES 7 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts1.farend.1day.UAS 10 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 OC192-XFP.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 OC192-XFP.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 Cisco ONS 15454 Reference Manual, R8.5.x C-62 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-18 OC192-XFP Default Settings (continued) Default Name Default Value Default Domain OC192-XFP.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 OC192-XFP.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts1.nearend.1day.FC 40 (count) 0 - 6912 OC192-XFP.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC192-XFP.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts12c-192c.farend.15min.CV 75 (B3 count) 0 - 2160000 OC192-XFP.pmthresholds.sts12c-192c.farend.15min.ES 60 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts12c-192c.farend.15min.FC 10 (count) 0 - 72 OC192-XFP.pmthresholds.sts12c-192c.farend.15min.SES 3 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts12c-192c.farend.15min.UAS 10 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts12c-192c.farend.1day.CV 750 (B3 count) 0 - 207360000 OC192-XFP.pmthresholds.sts12c-192c.farend.1day.ES 600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts12c-192c.farend.1day.FC 40 (count) 0 - 6912 OC192-XFP.pmthresholds.sts12c-192c.farend.1day.SES 7 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts12c-192c.farend.1day.UAS 10 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.CV 75 (B3 count) 0 - 2160000 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.ES 60 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.FC 10 (count) 0 - 72 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.NPJC-PGE N 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-63 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-18 OC192-XFP Default Settings (continued) Default Name Default Value Default Domain OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.SES 3 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts12c-192c.nearend.15min.UAS 10 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.CV 750 (B3 count) 0 - 207360000 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.ES 600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.FC 40 (count) 0 - 6912 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 691200000 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.SES 7 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts12c-192c.nearend.1day.UAS 10 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts3c-9c.farend.15min.CV 25 (B3 count) 0 - 2160000 OC192-XFP.pmthresholds.sts3c-9c.farend.15min.ES 20 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts3c-9c.farend.15min.FC 10 (count) 0 - 72 OC192-XFP.pmthresholds.sts3c-9c.farend.15min.SES 3 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts3c-9c.farend.15min.UAS 10 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts3c-9c.farend.1day.CV 250 (B3 count) 0 - 207360000 OC192-XFP.pmthresholds.sts3c-9c.farend.1day.ES 200 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts3c-9c.farend.1day.FC 40 (count) 0 - 6912 OC192-XFP.pmthresholds.sts3c-9c.farend.1day.SES 7 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts3c-9c.farend.1day.UAS 10 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.CV 25 (B3 count) 0 - 2160000 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.ES 20 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.FC 10 (count) 0 - 72 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 Cisco ONS 15454 Reference Manual, R8.5.x C-64 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-18 OC192-XFP Default Settings (continued) Default Name Default Value Default Domain OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.SES 3 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts3c-9c.nearend.15min.UAS 10 (seconds) 0 - 900 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.CV 250 (B3 count) 0 - 207360000 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.ES 200 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.FC 40 (count) 0 - 6912 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.SES 7 (seconds) 0 - 86400 OC192-XFP.pmthresholds.sts3c-9c.nearend.1day.UAS 10 (seconds) 0 - 86400 C.2.3.19 MRC-12 Card Default Settings Table C-19 lists the MRC-12 card default settings. Table C-19 MRC-12 Card Default Settings Default Name Default Value Default Domain MRC-12.OC12-PORT.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 MRC-12.OC12-PORT.config.line.AlsMode Disabled Disabled, Auto Restart, Manual Restart, Manual Restart for Test MRC-12.OC12-PORT.config.line.AlsRecoveryPulseDuration 2.0 (seconds) 2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test MRC-12.OC12-PORT.config.line.AlsRecoveryPulseInterval 100 (seconds) 60 - 300 MRC-12.OC12-PORT.config.line.PJStsMon# 0 (STS #) 0 - 12 MRC-12.OC12-PORT.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-65 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC12-PORT.config.line.sdh.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE MRC-12.OC12-PORT.config.line.sdh.SendDoNotUse FALSE FALSE, TRUE MRC-12.OC12-PORT.config.line.sdh.SyncMsgIn TRUE FALSE, TRUE MRC-12.OC12-PORT.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE MRC-12.OC12-PORT.config.line.SendAISOnTerminalLoopback TRUE TRUE, FALSE MRC-12.OC12-PORT.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 MRC-12.OC12-PORT.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE MRC-12.OC12-PORT.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE MRC-12.OC12-PORT.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE MRC-12.OC12-PORT.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS MRC-12.OC12-PORT.config.sts.IPPMEnabled FALSE TRUE, FALSE MRC-12.OC12-PORT.physicalthresholds.alarm.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC-12.OC12-PORT.physicalthresholds.alarm.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC-12.OC12-PORT.physicalthresholds.alarm.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC-12.OC12-PORT.physicalthresholds.alarm.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC-12.OC12-PORT.physicalthresholds.alarm.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC-12.OC12-PORT.physicalthresholds.alarm.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC-12.OC12-PORT.physicalthresholds.warning.15min.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC-12.OC12-PORT.physicalthresholds.warning.15min.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC-12.OC12-PORT.physicalthresholds.warning.15min.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC-12.OC12-PORT.physicalthresholds.warning.15min.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC-12.OC12-PORT.physicalthresholds.warning.15min.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC-12.OC12-PORT.physicalthresholds.warning.15min.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC-12.OC12-PORT.physicalthresholds.warning.1day.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC-12.OC12-PORT.physicalthresholds.warning.1day.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH Cisco ONS 15454 Reference Manual, R8.5.x C-66 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC12-PORT.physicalthresholds.warning.1day.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC-12.OC12-PORT.physicalthresholds.warning.1day.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC-12.OC12-PORT.physicalthresholds.warning.1day.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC-12.OC12-PORT.physicalthresholds.warning.1day.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC-12.OC12-PORT.pmthresholds.line.farend.15min.CV 5315 (B2 count) 0 - 552600 MRC-12.OC12-PORT.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 MRC-12.OC12-PORT.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.line.farend.1day.CV 53150 (B2 count) 0 - 53049600 MRC-12.OC12-PORT.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC12-PORT.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.line.nearend.15min.CV 5315 (B2 count) 0 - 552600 MRC-12.OC12-PORT.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC12-PORT.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 MRC-12.OC12-PORT.pmthresholds.line.nearend.15min.PSC-W 1 (count) 0 - 600 MRC-12.OC12-PORT.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.line.nearend.15min.PSD-W 300 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.line.nearend.1day.CV 53150 (B2 count) 0 - 53049600 MRC-12.OC12-PORT.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC12-PORT.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 MRC-12.OC12-PORT.pmthresholds.line.nearend.1day.PSC-W 5 (count) 0 - 57600 MRC-12.OC12-PORT.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.line.nearend.1day.PSD-W 600 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-67 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC12-PORT.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 553500 MRC-12.OC12-PORT.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 53136000 MRC-12.OC12-PORT.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts1.farend.15min.CV 15 (B3 count) 0 - 2160000 MRC-12.OC12-PORT.pmthresholds.sts1.farend.15min.ES 12 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts1.farend.15min.FC 10 (count) 0 - 72 MRC-12.OC12-PORT.pmthresholds.sts1.farend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts1.farend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts1.farend.1day.CV 125 (B3 count) 0 - 207360000 MRC-12.OC12-PORT.pmthresholds.sts1.farend.1day.ES 100 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts1.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC12-PORT.pmthresholds.sts1.farend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts1.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 Cisco ONS 15454 Reference Manual, R8.5.x C-68 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts12c.farend.15min.CV 75 (B3 count) 0 - 2160000 MRC-12.OC12-PORT.pmthresholds.sts12c.farend.15min.ES 60 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts12c.farend.15min.FC 10 (count) 0 - 72 MRC-12.OC12-PORT.pmthresholds.sts12c.farend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts12c.farend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts12c.farend.1day.CV 750 (B3 count) 0 - 207360000 MRC-12.OC12-PORT.pmthresholds.sts12c.farend.1day.ES 600 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts12c.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC12-PORT.pmthresholds.sts12c.farend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts12c.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.CV 75 (B3 count) 0 - 2160000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.ES 60 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.15min.UAS 10 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-69 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.CV 750 (B3 count) 0 - 207360000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.ES 600 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts12c.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.farend.15min.CV 25 (B3 count) 0 - 2160000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.farend.15min.ES 20 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.farend.15min.FC 10 (count) 0 - 72 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.farend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.farend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.farend.1day.CV 250 (B3 count) 0 - 207360000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.farend.1day.ES 200 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.farend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.CV 25 (B3 count) 0 - 2160000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.ES 20 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.SES 3 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x C-70 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.CV 250 (B3 count) 0 - 207360000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.ES 200 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC3-PORT.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 MRC-12.OC3-PORT.config.line.AlsMode Disabled Disabled, Auto Restart, Manual Restart, Manual Restart for Test MRC-12.OC3-PORT.config.line.AlsRecoveryPulseDuration 2.0 (seconds) 2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test MRC-12.OC3-PORT.config.line.AlsRecoveryPulseInterval 100 (seconds) 60 - 300 MRC-12.OC3-PORT.config.line.PJStsMon# 0 (STS #) 0-3 MRC-12.OC3-PORT.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 MRC-12.OC3-PORT.config.line.sdh.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE MRC-12.OC3-PORT.config.line.sdh.SendDoNotUse FALSE FALSE, TRUE MRC-12.OC3-PORT.config.line.sdh.SyncMsgIn TRUE FALSE, TRUE MRC-12.OC3-PORT.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE MRC-12.OC3-PORT.config.line.SendAISOnTerminalLoopback TRUE TRUE, FALSE MRC-12.OC3-PORT.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-71 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC3-PORT.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE MRC-12.OC3-PORT.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE MRC-12.OC3-PORT.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE MRC-12.OC3-PORT.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS MRC-12.OC3-PORT.config.sts.IPPMEnabled FALSE TRUE, FALSE MRC-12.OC3-PORT.physicalthresholds.alarm.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC-12.OC3-PORT.physicalthresholds.alarm.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC-12.OC3-PORT.physicalthresholds.alarm.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC-12.OC3-PORT.physicalthresholds.alarm.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC-12.OC3-PORT.physicalthresholds.alarm.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC-12.OC3-PORT.physicalthresholds.alarm.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC-12.OC3-PORT.physicalthresholds.warning.15min.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC-12.OC3-PORT.physicalthresholds.warning.15min.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC-12.OC3-PORT.physicalthresholds.warning.15min.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC-12.OC3-PORT.physicalthresholds.warning.15min.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC-12.OC3-PORT.physicalthresholds.warning.15min.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC-12.OC3-PORT.physicalthresholds.warning.15min.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC-12.OC3-PORT.physicalthresholds.warning.1day.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC-12.OC3-PORT.physicalthresholds.warning.1day.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC-12.OC3-PORT.physicalthresholds.warning.1day.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC-12.OC3-PORT.physicalthresholds.warning.1day.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC-12.OC3-PORT.physicalthresholds.warning.1day.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC-12.OC3-PORT.physicalthresholds.warning.1day.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC-12.OC3-PORT.pmthresholds.line.farend.15min.CV 1312 (B2 count) 0 - 137700 MRC-12.OC3-PORT.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 Cisco ONS 15454 Reference Manual, R8.5.x C-72 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC3-PORT.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.line.farend.1day.CV 13120 (B2 count) 0 - 13219200 MRC-12.OC3-PORT.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC3-PORT.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.line.nearend.15min.CV 1312 (B2 count) 0 - 137700 MRC-12.OC3-PORT.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC3-PORT.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 MRC-12.OC3-PORT.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.line.nearend.1day.CV 13120 (B2 count) 0 - 13219200 MRC-12.OC3-PORT.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC3-PORT.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 MRC-12.OC3-PORT.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 138600 MRC-12.OC3-PORT.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 13305600 MRC-12.OC3-PORT.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts1.farend.15min.CV 15 (B3 count) 0 - 2160000 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-73 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC3-PORT.pmthresholds.sts1.farend.15min.ES 12 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts1.farend.15min.FC 10 (count) 0 - 72 MRC-12.OC3-PORT.pmthresholds.sts1.farend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts1.farend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts1.farend.1day.CV 125 (B3 count) 0 - 207360000 MRC-12.OC3-PORT.pmthresholds.sts1.farend.1day.ES 100 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts1.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC3-PORT.pmthresholds.sts1.farend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts1.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x C-74 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC3-PORT.pmthresholds.sts3c.farend.15min.CV 25 (B3 count) 0 - 2160000 MRC-12.OC3-PORT.pmthresholds.sts3c.farend.15min.ES 20 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts3c.farend.15min.FC 10 (count) 0 - 72 MRC-12.OC3-PORT.pmthresholds.sts3c.farend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts3c.farend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts3c.farend.1day.CV 250 (B3 count) 0 - 207360000 MRC-12.OC3-PORT.pmthresholds.sts3c.farend.1day.ES 200 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts3c.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC3-PORT.pmthresholds.sts3c.farend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts3c.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.CV 25 (B3 count) 0 - 2160000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.ES 20 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.CV 250 (B3 count) 0 - 207360000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.ES 200 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.SES 7 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-75 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC3-PORT.pmthresholds.sts3c.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC48-PORT.config.line.AINSSoakTime 08:00 (hours:mins) 00:00, 00:15, 00:30 .. 48:00 MRC-12.OC48-PORT.config.line.AlsMode Disabled Disabled, Auto Restart, Manual Restart, Manual Restart for Test MRC-12.OC48-PORT.config.line.AlsRecoveryPulseDuration 2.0 (seconds) 2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test MRC-12.OC48-PORT.config.line.AlsRecoveryPulseInterval 100 (seconds) 60 - 300 MRC-12.OC48-PORT.config.line.PJStsMon# 0 (STS #) 0 - 48 MRC-12.OC48-PORT.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 MRC-12.OC48-PORT.config.line.sdh.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE MRC-12.OC48-PORT.config.line.sdh.SendDoNotUse FALSE FALSE, TRUE MRC-12.OC48-PORT.config.line.sdh.SyncMsgIn TRUE FALSE, TRUE MRC-12.OC48-PORT.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE MRC-12.OC48-PORT.config.line.SendAISOnTerminalLoopback TRUE TRUE, FALSE MRC-12.OC48-PORT.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 MRC-12.OC48-PORT.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE MRC-12.OC48-PORT.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE MRC-12.OC48-PORT.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE MRC-12.OC48-PORT.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS MRC-12.OC48-PORT.config.sts.IPPMEnabled FALSE TRUE, FALSE MRC-12.OC48-PORT.physicalthresholds.alarm.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC-12.OC48-PORT.physicalthresholds.alarm.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC-12.OC48-PORT.physicalthresholds.alarm.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC-12.OC48-PORT.physicalthresholds.alarm.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH Cisco ONS 15454 Reference Manual, R8.5.x C-76 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC48-PORT.physicalthresholds.alarm.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC-12.OC48-PORT.physicalthresholds.alarm.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC-12.OC48-PORT.physicalthresholds.warning.15min.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC-12.OC48-PORT.physicalthresholds.warning.15min.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC-12.OC48-PORT.physicalthresholds.warning.15min.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC-12.OC48-PORT.physicalthresholds.warning.15min.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC-12.OC48-PORT.physicalthresholds.warning.15min.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC-12.OC48-PORT.physicalthresholds.warning.15min.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC-12.OC48-PORT.physicalthresholds.warning.1day.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC-12.OC48-PORT.physicalthresholds.warning.1day.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC-12.OC48-PORT.physicalthresholds.warning.1day.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC-12.OC48-PORT.physicalthresholds.warning.1day.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC-12.OC48-PORT.physicalthresholds.warning.1day.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC-12.OC48-PORT.physicalthresholds.warning.1day.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC-12.OC48-PORT.pmthresholds.line.farend.15min.CV 21260 (B2 count) 0 - 2212200 MRC-12.OC48-PORT.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 MRC-12.OC48-PORT.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.line.farend.1day.CV 212600 (B2 count) 0 - 212371200 MRC-12.OC48-PORT.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC48-PORT.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.CV 21260 (B2 count) 0 - 2212200 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.PSC-R 1 (count) 0 - 600 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-77 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.PSC-S 1 (count) 0 - 600 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.PSC-W 1 (count) 0 - 600 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.PSD-R 300 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.PSD-S 300 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.PSD-W 300 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.CV 212600 (B2 count) 0 - 212371200 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.PSC-R 5 (count) 0 - 57600 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.PSC-S 5 (count) 0 - 57600 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.PSC-W 5 (count) 0 - 57600 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.PSD-R 600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.PSD-S 600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.PSD-W 600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 2151900 MRC-12.OC48-PORT.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 206582400 MRC-12.OC48-PORT.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts1.farend.15min.CV 15 (B3 count) 0 - 2160000 MRC-12.OC48-PORT.pmthresholds.sts1.farend.15min.ES 12 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts1.farend.15min.FC 10 (count) 0 - 72 Cisco ONS 15454 Reference Manual, R8.5.x C-78 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC48-PORT.pmthresholds.sts1.farend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts1.farend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts1.farend.1day.CV 125 (B3 count) 0 - 207360000 MRC-12.OC48-PORT.pmthresholds.sts1.farend.1day.ES 100 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts1.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC48-PORT.pmthresholds.sts1.farend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts1.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.farend.15min.CV 75 (B3 count) 0 - 2160000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.farend.15min.ES 60 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-79 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC48-PORT.pmthresholds.sts12c-48c.farend.15min.FC 10 (count) 0 - 72 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.farend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.farend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.farend.1day.CV 750 (B3 count) 0 - 207360000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.farend.1day.ES 600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.farend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.CV 75 (B3 count) 0 - 2160000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.ES 60 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.CV 750 (B3 count) 0 - 207360000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.ES 600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.farend.15min.CV 25 (B3 count) 0 - 2160000 Cisco ONS 15454 Reference Manual, R8.5.x C-80 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-19 MRC-12 Card Default Settings (continued) Default Name Default Value Default Domain MRC-12.OC48-PORT.pmthresholds.sts3c-9c.farend.15min.ES 20 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.farend.15min.FC 10 (count) 0 - 72 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.farend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.farend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.farend.1day.CV 250 (B3 count) 0 - 207360000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.farend.1day.ES 200 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.farend.1day.FC 40 (count) 0 - 6912 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.farend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.farend.1day.UAS 10 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.CV 25 (B3 count) 0 - 2160000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.ES 20 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.FC 10 (count) 0 - 72 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.SES 3 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.UAS 10 (seconds) 0 - 900 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.CV 250 (B3 count) 0 - 207360000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.ES 200 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.FC 40 (count) 0 - 6912 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.SES 7 (seconds) 0 - 86400 MRC-12.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.UAS 10 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-81 Appendix C Network Element Defaults C.2.3 Defaults by Card C.2.3.20 MRC-2.5G-4 Card Default Settings Table C-20 lists the MRC-2.5G-4 card default settings. Table C-20 MRC-2.5G-4 Card Default Settings Default Name Default Value Default Domain MRC25G-4.OC12-PORT.config.line.AINSSoakTime 08:00 00:00, 00:15, 00:30 .. (hours:mins) 48:00 MRC25G-4.OC12-PORT.config.line.AlsMode Disabled MRC25G-4.OC12-PORT.config.line.AlsRecoveryPulseDuration 2.0 (seconds) 2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test MRC25G-4.OC12-PORT.config.line.AlsRecoveryPulseInterval 100 (seconds) 60 - 300 MRC25G-4.OC12-PORT.config.line.PJStsMon# 0 (STS #) 0 - 12 MRC25G-4.OC12-PORT.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 MRC25G-4.OC12-PORT.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE MRC25G-4.OC12-PORT.config.line.SendAISOnTerminalLoopback TRUE TRUE, FALSE MRC25G-4.OC12-PORT.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 MRC25G-4.OC12-PORT.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE MRC25G-4.OC12-PORT.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE MRC25G-4.OC12-PORT.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE MRC25G-4.OC12-PORT.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS MRC25G-4.OC12-PORT.config.sts.IPPMEnabled FALSE TRUE, FALSE MRC25G-4.OC12-PORT.physicalthresholds.alarm.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC25G-4.OC12-PORT.physicalthresholds.alarm.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC25G-4.OC12-PORT.physicalthresholds.alarm.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC25G-4.OC12-PORT.physicalthresholds.alarm.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC25G-4.OC12-PORT.physicalthresholds.alarm.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC25G-4.OC12-PORT.physicalthresholds.alarm.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH Disabled, Auto Restart, Manual Restart, Manual Restart for Test Cisco ONS 15454 Reference Manual, R8.5.x C-82 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC12-PORT.physicalthresholds.warning.15min.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC25G-4.OC12-PORT.physicalthresholds.warning.15min.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC25G-4.OC12-PORT.physicalthresholds.warning.15min.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC25G-4.OC12-PORT.physicalthresholds.warning.15min.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC25G-4.OC12-PORT.physicalthresholds.warning.15min.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC25G-4.OC12-PORT.physicalthresholds.warning.15min.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC25G-4.OC12-PORT.physicalthresholds.warning.1day.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC25G-4.OC12-PORT.physicalthresholds.warning.1day.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC25G-4.OC12-PORT.physicalthresholds.warning.1day.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC25G-4.OC12-PORT.physicalthresholds.warning.1day.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC25G-4.OC12-PORT.physicalthresholds.warning.1day.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC25G-4.OC12-PORT.physicalthresholds.warning.1day.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC25G-4.OC12-PORT.pmthresholds.line.farend.15min.CV 5315 (B2 count) 0 - 552600 MRC25G-4.OC12-PORT.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC12-PORT.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.line.farend.1day.CV 53150 (B2 count) 0 - 53049600 MRC25G-4.OC12-PORT.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC12-PORT.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.15min.CV 5315 (B2 count) 0 - 552600 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.15min.PSC-W 1 (count) 0 - 600 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-83 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC12-PORT.pmthresholds.line.nearend.15min.PSD-W 300 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.1day.CV 53150 (B2 count) 0 - 53049600 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.1day.PSC-W 5 (count) 0 - 57600 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.1day.PSD-W 600 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 553500 MRC25G-4.OC12-PORT.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 53136000 MRC25G-4.OC12-PORT.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts1.farend.15min.CV 15 (B3 count) 0 - 2160000 MRC25G-4.OC12-PORT.pmthresholds.sts1.farend.15min.ES 12 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts1.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC12-PORT.pmthresholds.sts1.farend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts1.farend.15min.UAS 10 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x C-84 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC12-PORT.pmthresholds.sts1.farend.1day.CV 125 (B3 count) 0 - 207360000 MRC25G-4.OC12-PORT.pmthresholds.sts1.farend.1day.ES 100 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts1.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC12-PORT.pmthresholds.sts1.farend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts1.farend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-85 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC12-PORT.pmthresholds.sts12c.farend.15min.CV 75 (B3 count) 0 - 2160000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.farend.15min.ES 60 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts12c.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC12-PORT.pmthresholds.sts12c.farend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts12c.farend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts12c.farend.1day.CV 750 (B3 count) 0 - 207360000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.farend.1day.ES 600 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts12c.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC12-PORT.pmthresholds.sts12c.farend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts12c.farend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.CV 75 (B3 count) 0 - 2160000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.ES 60 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.CV 750 (B3 count) 0 - 207360000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.ES 600 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x C-86 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.PJCS-PGEN 9600 (seconds) MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts12c.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.farend.15min.CV 25 (B3 count) 0 - 2160000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.farend.15min.ES 20 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.farend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.farend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.farend.1day.CV 250 (B3 count) 0 - 207360000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.farend.1day.ES 200 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.farend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.farend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.CV 25 (B3 count) 0 - 2160000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.ES 20 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.CV 250 (B3 count) 0 - 207360000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.ES 200 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.FC 40 (count) 0 - 6912 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-87 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC12-PORT.pmthresholds.sts3c-9c.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.config.line.AINSSoakTime 08:00 00:00, 00:15, 00:30 .. (hours:mins) 48:00 MRC25G-4.OC3-PORT.config.line.AlsMode Disabled MRC25G-4.OC3-PORT.config.line.AlsRecoveryPulseDuration 2.0 (seconds) 2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test MRC25G-4.OC3-PORT.config.line.AlsRecoveryPulseInterval 100 (seconds) 60 - 300 MRC25G-4.OC3-PORT.config.line.PJStsMon# 0 (STS #) 0-3 MRC25G-4.OC3-PORT.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 MRC25G-4.OC3-PORT.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE MRC25G-4.OC3-PORT.config.line.SendAISOnTerminalLoopback TRUE TRUE, FALSE MRC25G-4.OC3-PORT.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 MRC25G-4.OC3-PORT.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE MRC25G-4.OC3-PORT.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE MRC25G-4.OC3-PORT.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE MRC25G-4.OC3-PORT.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS MRC25G-4.OC3-PORT.config.sts.IPPMEnabled FALSE TRUE, FALSE MRC25G-4.OC3-PORT.physicalthresholds.alarm.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 Disabled, Auto Restart, Manual Restart, Manual Restart for Test Cisco ONS 15454 Reference Manual, R8.5.x C-88 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC3-PORT.physicalthresholds.alarm.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC25G-4.OC3-PORT.physicalthresholds.alarm.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC25G-4.OC3-PORT.physicalthresholds.alarm.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC25G-4.OC3-PORT.physicalthresholds.alarm.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC25G-4.OC3-PORT.physicalthresholds.alarm.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC25G-4.OC3-PORT.physicalthresholds.warning.15min.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC25G-4.OC3-PORT.physicalthresholds.warning.15min.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC25G-4.OC3-PORT.physicalthresholds.warning.15min.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC25G-4.OC3-PORT.physicalthresholds.warning.15min.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC25G-4.OC3-PORT.physicalthresholds.warning.15min.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC25G-4.OC3-PORT.physicalthresholds.warning.15min.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC25G-4.OC3-PORT.physicalthresholds.warning.1day.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC25G-4.OC3-PORT.physicalthresholds.warning.1day.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC25G-4.OC3-PORT.physicalthresholds.warning.1day.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC25G-4.OC3-PORT.physicalthresholds.warning.1day.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC25G-4.OC3-PORT.physicalthresholds.warning.1day.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC25G-4.OC3-PORT.physicalthresholds.warning.1day.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC25G-4.OC3-PORT.pmthresholds.line.farend.15min.CV 1312 (B2 count) 0 - 137700 MRC25G-4.OC3-PORT.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC3-PORT.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.line.farend.1day.CV 13120 (B2 count) 0 - 13219200 MRC25G-4.OC3-PORT.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC3-PORT.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-89 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC3-PORT.pmthresholds.line.nearend.15min.CV 1312 (B2 count) 0 - 137700 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.1day.CV 13120 (B2 count) 0 - 13219200 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 138600 MRC25G-4.OC3-PORT.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 13305600 MRC25G-4.OC3-PORT.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts1.farend.15min.CV 15 (B3 count) 0 - 2160000 MRC25G-4.OC3-PORT.pmthresholds.sts1.farend.15min.ES 12 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts1.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC3-PORT.pmthresholds.sts1.farend.15min.SES 3 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x C-90 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC3-PORT.pmthresholds.sts1.farend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts1.farend.1day.CV 125 (B3 count) 0 - 207360000 MRC25G-4.OC3-PORT.pmthresholds.sts1.farend.1day.ES 100 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts1.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC3-PORT.pmthresholds.sts1.farend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts1.farend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-91 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC3-PORT.pmthresholds.sts3c.farend.15min.CV 25 (B3 count) 0 - 2160000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.farend.15min.ES 20 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts3c.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC3-PORT.pmthresholds.sts3c.farend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts3c.farend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts3c.farend.1day.CV 250 (B3 count) 0 - 207360000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.farend.1day.ES 200 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts3c.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC3-PORT.pmthresholds.sts3c.farend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts3c.farend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.CV 25 (B3 count) 0 - 2160000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.ES 20 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.CV 250 (B3 count) 0 - 207360000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.ES 200 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 Cisco ONS 15454 Reference Manual, R8.5.x C-92 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.PJCS-PGEN 9600 (seconds) MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC3-PORT.pmthresholds.sts3c.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.config.line.AINSSoakTime 08:00 00:00, 00:15, 00:30 .. (hours:mins) 48:00 MRC25G-4.OC48-PORT.config.line.AlsMode Disabled MRC25G-4.OC48-PORT.config.line.AlsRecoveryPulseDuration 2.0 (seconds) 2.0, 2.1, 2.2 .. 100.0 when AlsMode Disabled, Auto Restart, Manual Restart; 80.0, 80.1, 80.2 .. 100.0 when AlsMode Manual Restart for Test MRC25G-4.OC48-PORT.config.line.AlsRecoveryPulseInterval 100 (seconds) 60 - 300 MRC25G-4.OC48-PORT.config.line.PJStsMon# 0 (STS #) 0 - 48 MRC25G-4.OC48-PORT.config.line.SDBER 1.00E-07 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 MRC25G-4.OC48-PORT.config.line.SendAISOnFacilityLoopback TRUE TRUE, FALSE MRC25G-4.OC48-PORT.config.line.SendAISOnTerminalLoopback TRUE TRUE, FALSE MRC25G-4.OC48-PORT.config.line.SFBER 1.00E-04 1E-3, 1E-4, 1E-5 MRC25G-4.OC48-PORT.config.line.sonet.Send DoNotUse FALSE FALSE when SendDoNotUse TRUE; FALSE, TRUE when SendDoNotUse FALSE MRC25G-4.OC48-PORT.config.line.sonet.SendDoNotUse FALSE FALSE, TRUE MRC25G-4.OC48-PORT.config.line.sonet.SyncMsgIn TRUE FALSE, TRUE MRC25G-4.OC48-PORT.config.line.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS MRC25G-4.OC48-PORT.config.sts.IPPMEnabled FALSE TRUE, FALSE MRC25G-4.OC48-PORT.physicalthresholds.alarm.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC25G-4.OC48-PORT.physicalthresholds.alarm.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC25G-4.OC48-PORT.physicalthresholds.alarm.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC25G-4.OC48-PORT.physicalthresholds.alarm.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH 0 - 86400 Disabled, Auto Restart, Manual Restart, Manual Restart for Test Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-93 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC48-PORT.physicalthresholds.alarm.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC25G-4.OC48-PORT.physicalthresholds.alarm.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC25G-4.OC48-PORT.physicalthresholds.warning.15min.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC25G-4.OC48-PORT.physicalthresholds.warning.15min.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC25G-4.OC48-PORT.physicalthresholds.warning.15min.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC25G-4.OC48-PORT.physicalthresholds.warning.15min.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC25G-4.OC48-PORT.physicalthresholds.warning.15min.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC25G-4.OC48-PORT.physicalthresholds.warning.15min.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC25G-4.OC48-PORT.physicalthresholds.warning.1day.LBC-HIGH 200 (%) LBC-LOW, LBC-LOW + 1, LBC-LOW + 2 .. 255 MRC25G-4.OC48-PORT.physicalthresholds.warning.1day.LBC-LOW 20 (%) 0, 1, 2 .. LBC-HIGH MRC25G-4.OC48-PORT.physicalthresholds.warning.1day.OPR-HIGH 200 (%) OPR-LOW, OPR-LOW + 1, OPR-LOW + 2 .. 255 MRC25G-4.OC48-PORT.physicalthresholds.warning.1day.OPR-LOW 50 (%) -1, 0, 1 .. OPR-HIGH MRC25G-4.OC48-PORT.physicalthresholds.warning.1day.OPT-HIGH 120 (%) OPT-LOW, OPT-LOW + 1, OPT-LOW + 2 .. 255 MRC25G-4.OC48-PORT.physicalthresholds.warning.1day.OPT-LOW 80 (%) 0, 1, 2 .. OPT-HIGH MRC25G-4.OC48-PORT.pmthresholds.line.farend.15min.CV 21260 (B2 count) 0 - 2212200 MRC25G-4.OC48-PORT.pmthresholds.line.farend.15min.ES 87 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.line.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC48-PORT.pmthresholds.line.farend.15min.SES 1 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.line.farend.15min.UAS 3 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.line.farend.1day.CV 212600 (B2 count) 0 - 212371200 MRC25G-4.OC48-PORT.pmthresholds.line.farend.1day.ES 864 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.line.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC48-PORT.pmthresholds.line.farend.1day.SES 4 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.line.farend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.CV 21260 (B2 count) 0 - 2212200 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.ES 87 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.PSC 1 (count) 0 - 600 Cisco ONS 15454 Reference Manual, R8.5.x C-94 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.PSC-R 1 (count) 0 - 600 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.PSC-S 1 (count) 0 - 600 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.PSC-W 1 (count) 0 - 600 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.PSD 300 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.PSD-R 300 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.PSD-S 300 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.PSD-W 300 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.SES 1 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.15min.UAS 3 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.CV 212600 (B2 count) 0 - 212371200 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.ES 864 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.PSC 5 (count) 0 - 57600 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.PSC-R 5 (count) 0 - 57600 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.PSC-S 5 (count) 0 - 57600 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.PSC-W 5 (count) 0 - 57600 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.PSD 600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.PSD-R 600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.PSD-S 600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.PSD-W 600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.SES 4 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.line.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.section.nearend.15min.CV 10000 (B1 count) 0 - 2151900 MRC25G-4.OC48-PORT.pmthresholds.section.nearend.15min.ES 500 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.section.nearend.15min.SEFS 500 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.section.nearend.15min.SES 500 (seconds) 0 - 900 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-95 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC48-PORT.pmthresholds.section.nearend.1day.CV 100000 (B1 count) 0 - 206582400 MRC25G-4.OC48-PORT.pmthresholds.section.nearend.1day.ES 5000 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.section.nearend.1day.SEFS 5000 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.section.nearend.1day.SES 5000 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts1.farend.15min.CV 15 (B3 count) 0 - 2160000 MRC25G-4.OC48-PORT.pmthresholds.sts1.farend.15min.ES 12 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts1.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC48-PORT.pmthresholds.sts1.farend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts1.farend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts1.farend.1day.CV 125 (B3 count) 0 - 207360000 MRC25G-4.OC48-PORT.pmthresholds.sts1.farend.1day.ES 100 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts1.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC48-PORT.pmthresholds.sts1.farend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts1.farend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.CV 15 (B3 count) 0 - 2160000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.ES 12 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.CV 125 (B3 count) 0 - 207360000 Cisco ONS 15454 Reference Manual, R8.5.x C-96 78-18106-01 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.ES 100 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts1.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.farend.15min.CV 75 (B3 count) 0 - 2160000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.farend.15min.ES 60 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.farend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.farend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.farend.1day.CV 750 (B3 count) 0 - 207360000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.farend.1day.ES 600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.farend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.farend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.CV 75 (B3 count) 0 - 2160000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.ES 60 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-97 Appendix C Network Element Defaults C.2.3 Defaults by Card Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.CV 750 (B3 count) 0 - 207360000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.ES 600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts12c-48c.nearend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.farend.15min.CV 25 (B3 count) 0 - 2160000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.farend.15min.ES 20 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.farend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.farend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.farend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.farend.1day.CV 250 (B3 count) 0 - 207360000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.farend.1day.ES 200 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.farend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.farend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.farend.1day.UAS 10 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.CV 25 (B3 count) 0 - 2160000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.ES 20 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.FC 10 (count) 0 - 72 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.NPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 Cisco ONS 15454 Reference Manual, R8.5.x C-98 78-18106-01 Appendix C Network Element Defaults C.3 Node Default Settings Table C-20 MRC-2.5G-4 Card Default Settings (continued) Default Name Default Value Default Domain MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCS-PDET 100 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.PPJC-PGEN 60 (count) 0 - 7200000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.SES 3 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.15min.UAS 10 (seconds) 0 - 900 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.CV 250 (B3 count) 0 - 207360000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.ES 200 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.FC 40 (count) 0 - 6912 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.NPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.NPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCDIFF 5760 (count) 0 - 1382400000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCS-PDET 9600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.PJCS-PGEN 9600 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.PPJC-PDET 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.PPJC-PGEN 5760 (count) 0 - 691200000 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.SES 7 (seconds) 0 - 86400 MRC25G-4.OC48-PORT.pmthresholds.sts3c-9c.nearend.1day.UAS 10 (seconds) 0 - 86400 C.3 Node Default Settings Table C-21 on page C-101 lists the node-level default settings for the Cisco ONS 15454. Cisco provides the following user-configurable defaults for each Cisco ONS 15454 node: • Circuit settings—Set the administrative state and path protection circuit defaults, and whether to have circuits send a payload defect indication condition (PDIP). • General settings—Set general node management defaults, including whether to use Daylight Savings Time (DST), whether to insert Alarm Indication Signal VT (AIS-V) in each VT when the carrying STS crosses the signal degrade (SD) path bit error rate (BER) threshold, the IP address of the Network Time Protocol/Simple Network Time Protocol (NTP/SNTP) server to be used, the time zone where the node is located, the SD path BER value, the defaults description, whether to raise a condition on an empty card slot, whether automatic autonomous Transcation Language One (TL1) reporting of PM data is enabled for cross-connect paths on the node, whether or not to allow ports Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-99 Appendix C Network Element Defaults C.3 Node Default Settings to be disabled when they are providing services (when the default is set to FALSE users must remove or disable the services first, then put the ports out of service), and whether to report loopback conditions on Out-of-Service, Maintenance (OOS-MT) state ports. • Power Monitor settings—Set default voltage thresholds for the node. • Network settings—Set whether to prevent display of node IP addresses in CTC (applicable for all users except Superusers); default gateway node type; whether to raise an alarm when the backplane LAN cable is disconnected; and whether to display the IP address in the LCD in an editable mode (in which you can change the IP address directly from LCD screen), to display the IP address on the LCD as read-only, or to suppress display of the IP on the LCD entirely. • OSI settings—Set the Open System Interconnection (OSI) main setup, generic routing encapsulation (GRE) tunnel default, the link access protocol on the D channel (LAP-D), the router subnet, and the TID address resolution protocol (TARP) settings. • 1+1 and Optimized 1+1 protection settings—Set whether or not protected circuits have bidirectional switching, are revertive, and what the reversion time is; set optimized 1+1 detection, recovery, and verify guard timer values. Note Optimized 1+1 supports three timers that ensure the correct state of the cards at key points in card communication. A verification guard timer is used when a Force is issued, to ensure that the far end has a chance to respond. A detection guard timer is used to ensure the presence of an SF/SD condition before switching away from a card. A recover guard timer ensures the absence of SF/SD prior to switching to a card. You can change the default number of seconds before these timers expire by changing the NE default for the corresponding timer to a value within its domain of allowable values. • BLSR protection settings—Set whether BLSR-protected circuits are revertive, and what the reversion time is, at both the ring and span levels. • Legal Disclaimer—Set the legal disclaimer that warns users at the login screen about the possible legal or contractual ramifications of accessing equipment, systems, or networks without authorization. • Security Grant Permissions—Set default user security levels for activating/reverting software, PM data clearing, database restoring, and retrieving audit logs. • Security DataComm settings—Set default security settings for TCC Ethernet IP address and IP netmask, and CTC backplane IP suppression; set secure mode on and secure mode locked (for TCC2P cards only). Note The secure mode supported setting is not user-configurable; rather, it depends upon the presence or absence of TCC2P cards on the node for its setting. • Security Access settings—Set default security settings for LAN access, shell access, serial craft access, element management system (EMS) access (including Internet Inter-Object Request Broker Protocol [IIOP] listener port number), TL1 access, and Simple Network Management Protocol (SNMP) access. • Security RADIUS settings—Set default RADIUS server settings for the accounting port number and the authentication port number, and whether to enable the node as a final authenticator. Cisco ONS 15454 Reference Manual, R8.5.x C-100 78-18106-01 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 • Security Policy settings—Set the allowable failed logins before lockout, idle user timeout for each user level, optional lockout duration or manual unlock enabled, password reuse and change frequency policies, number of characters difference that is required between the old and new password, password aging by security level, enforced single concurrent session per user, and option to disable inactive user after a set inactivity period. • Security Password settings—Set when passwords can be changed, how many characters they must differ by, whether or not password reuse is allowed, and whether a password change is required on first login to a new account; set password aging enforcement and user-level specific aging and warning periods; set how many consecutive identical characters are allowed in a password, maximum password length, minimum password length, minimum number and combination of nonalphabetical characters required, and whether or not to allow a password that is a reversal of the login ID associated with the password. • BITS Timing settings—Set the AIS threshold, Admin synchronization status messaging (SSM), coding, facility type, framing, state, and line build-out (LBO) settings for building integrated timing supply 1 (BITS-1) and BITS2 timing. • General Timing settings—Set the mode (External, Line, or Mixed), quality of reserved (RES) timing (the rule that defines the order of clock quality from lowest to highest), revertive, reversion time, and SSM message set for node timing. Note Any node level defaults changed using the Provisioning > Defaults tab, changes existing node level provisioning. Although this is service affecting, it depends on the type of defaults changed, for example, general, and all timing and security attributes. The “Changing default values for some node level attributes overrides the current provisioning.” message is displayed. The Side Effects column of the Defaults editor (right-click a column header and select Show Column > Side Effects) explains the effect of changing the default values. However, when the card level defaults are changed using the Provisioning > Defaults tab, existing card provisioning remains unaffected. Note For more information about each individual node setting, refer to the “Change Node Settings” chapter of the Cisco ONS 15454 Procedure Guide. Node Default Settings Default Name Default Value Default Domain NODE.circuits.SendPDIP TRUE TRUE, FALSE NODE.circuits.State IS,AINS IS, OOS,DSBLD, OOS,MT, IS,AINS NODE.circuits.pathprotection.AllowpathprotectionOverOnePlusOne FALSE TRUE, FALSE NODE.circuits.pathprotection.ProvisionWorkingGoAndReturnOnPrimaryPath TRUE TRUE, FALSE NODE.circuits.pathprotection.ReversionTime 5.0 (minutes) 0.5, 1.0, 1.5 .. 12.0 NODE.circuits.pathprotection.Revertive FALSE TRUE, FALSE NODE.circuits.pathprotection.STS_SDBER 1.00E-06 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 NODE.circuits.pathprotection.STS_SFBER 1.00E-04 1E-3, 1E-4, 1E-5 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-101 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.circuits.pathprotection.SwitchOnPDIP FALSE TRUE, FALSE NODE.circuits.pathprotection.VT_SDBER 1.00E-05 1E-5, 1E-6, 1E-7, 1E-8 NODE.circuits.pathprotection.VT_SFBER 1.00E-03 1E-3, 1E-4, 1E-5 NODE.general.AllowServiceAffectingPortChangeToDisabled TRUE FALSE, TRUE NODE.general.AutoPM FALSE FALSE, TRUE NODE.general.DefaultsDescription Factory Defaults Free form field NODE.general.InsertAISVOnSDP FALSE TRUE, FALSE NODE.general.NtpSntpServer 0.0.0.0 IP Address NODE.general.RaiseConditionOnEmptySlot FALSE TRUE, FALSE NODE.general.ReportLoopbackConditionsOnOOS-MTPorts FALSE FALSE, TRUE NODE.general.SDPBER 1.00E-06 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 NODE.general.TimeZone (GMT-08:00 ) Pacific Time (US & Canada), Tijuana (For applicable time zones, see Table C-22 on page C-118.) NODE.general.UseDST TRUE TRUE, FALSE NODE.lmp.controlChannel.AdminState OOS,DSBL D IS, OOS,DSBLD NODE.lmp.controlChannel.HelloDeadInterval 12000 (ms) maximum_of(20 00,MinHelloDea dInterval,product _of(HelloInterval ,3)), maximum_of(20 00,MinHelloDea dInterval,product _of(HelloInterval ,3)) + 1, maximum_of(20 00,MinHelloDea dInterval,product _of(HelloInterval ,3)) + 2 .. minimum_of(200 00,MaxHelloDea dInterval) Cisco ONS 15454 Reference Manual, R8.5.x C-102 78-18106-01 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.lmp.controlChannel.HelloInterval 500 (ms) maximum_of(30 0,MinHelloInterv al), maximum_of(30 0,MinHelloInterv al) + 1, maximum_of(30 0,MinHelloInterv al) + 2 .. minimum_of(500 0,MaxHelloInter val,quotient_of( HelloDeadInterv al,3)) NODE.lmp.controlChannel.MaxHelloDeadInterval 20000 (ms) maximum_of(20 00,HelloDeadInt erval,sum_of(Ma xHelloInterval,1) ), maximum_of(20 00,HelloDeadInt erval,sum_of(Ma xHelloInterval,1) ) + 1, maximum_of(20 00,HelloDeadInt erval,sum_of(Ma xHelloInterval,1) ) + 2 .. 20000 NODE.lmp.controlChannel.MaxHelloInterval 2000 (ms) maximum_of(30 0,HelloInterval), maximum_of(30 0,HelloInterval) + 1, maximum_of(30 0,HelloInterval) + 2 .. minimum_of(500 0,difference_of( MaxHelloDeadIn terval,1)) Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-103 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.lmp.controlChannel.MinHelloDeadInterval 2000 (ms) maximum_of(20 00,sum_of(MinH elloInterval,1)), maximum_of(20 00,sum_of(MinH elloInterval,1)) + 1, maximum_of(20 00,sum_of(MinH elloInterval,1)) + 2 .. minimum_of(200 00,HelloDeadInt erval) NODE.lmp.controlChannel.MinHelloInterval 300 (ms) 300, 301, 302 .. minimum_of(500 0,HelloInterval,d ifference_of(Min HelloDeadInterv al,1)) NODE.lmp.dataLink.Type Port Port, Component NODE.lmp.general.Allowed TRUE FALSE, TRUE NODE.lmp.general.Enabled FALSE FALSE, TRUE when Allowed TRUE; FALSE when Allowed FALSE NODE.lmp.general.LMP-WDM TRUE FALSE, TRUE NODE.lmp.general.Role OLS PEER, OLS NODE.lmp.teLink.AdminState OOS,DSBL D IS, OOS,DSBLD NODE.lmp.teLink.DWDM TRUE FALSE, TRUE NODE.lmp.teLink.MuxCapability Lambda Switch Packet Switch Level 1, Packet Switch - Level 2, Packet Switch Level 3, Packet Switch - Level 4, Layer 2 Switch, TDM Cross-connect, Lambda Switch, Fiber Switch NODE.network.general.AlarmMissingBackplaneLAN FALSE TRUE, FALSE NODE.network.general.CtcIpDisplaySuppression FALSE TRUE, FALSE Cisco ONS 15454 Reference Manual, R8.5.x C-104 78-18106-01 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.network.general.GatewaySettings None LeaveAsIs, None, ENE, GNE, ProxyOnlyNode NODE.network.general.LcdSetting Allow Configuratio n Allow Configuration, Display Only, Suppress Display NODE.osi.greTunnel.OspfCost 110 110 - 65535 NODE.osi.greTunnel.SubnetMask 24 (bits) 8, 9, 10 .. 32 NODE.osi.lapd.Mode AITS AITS, UITS NODE.osi.lapd.MTU 512 512, 513, 514 .. 1500 NODE.osi.lapd.Role Network Network, User NODE.osi.lapd.T200 200 (ms) 200, 300, 400 .. 20000 NODE.osi.lapd.T203 10000 (ms) 4000, 4100, 4200 .. 120000 NODE.osi.mainSetup.L1L2LSPBufferSize 512 (bytes) 512 - 1500 NODE.osi.mainSetup.L1LSPBufferSize 512 (bytes) 512 - 1500 NODE.osi.mainSetup.NodeRoutingMode Intermediate System Level 1 End System, Intermediate System Level 1, Intermediate System Level 1/Level 2 NODE.osi.subnet.DISPriority 63 1, 2, 3 .. 127 NODE.osi.subnet.ESH 10 (sec) 10, 20, 30 .. 1000 NODE.osi.subnet.GCCISISCost 60 1, 2, 3 .. 63 NODE.osi.subnet.IIH 3 (sec) 1, 2, 3 .. 600 NODE.osi.subnet.ISH 10 (sec) 10, 20, 30 .. 1000 NODE.osi.subnet.LANISISCost 20 1, 2, 3 .. 63 NODE.osi.subnet.LDCCISISCost 40 1, 2, 3 .. 63 NODE.osi.subnet.OSCISISCost 60 1, 2, 3 .. 63 NODE.osi.subnet.SDCCISISCost 60 1, 2, 3 .. 63 NODE.osi.tarp.L1DataCache TRUE FALSE, TRUE NODE.osi.tarp.L2DataCache FALSE FALSE, TRUE NODE.osi.tarp.LANStormSuppression TRUE FALSE, TRUE NODE.osi.tarp.LDB TRUE FALSE, TRUE NODE.osi.tarp.LDBEntry 5 (min) 1 - 10 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-105 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.osi.tarp.LDBFlush 5 (min) 0 - 1440 NODE.osi.tarp.PDUsL1Propagation TRUE FALSE, TRUE NODE.osi.tarp.PDUsL2Propagation TRUE FALSE, TRUE NODE.osi.tarp.PDUsOrigination TRUE FALSE, TRUE NODE.osi.tarp.T1Timer 15 (sec) 0 - 3600 NODE.osi.tarp.T2Timer 25 (sec) 0 - 3600 NODE.osi.tarp.T3Timer 40 (sec) 0 - 3600 NODE.osi.tarp.T4Timer 20 (sec) 0 - 3600 NODE.osi.tarp.Type4PDUDelay 0 (sec) 0 - 255 NODE.powerMonitor.EHIBATVG -56.5 (Vdc) -54.0, -54.5, -55.0, -55.5, -56.0, -56.5 NODE.powerMonitor.ELWBATVG -40.5 (Vdc) -40.5, -41.0, -41.5, -42.0, -42.5, -43.0, -43.5, -44.0 NODE.powerMonitor.HIBATVG -54.0 (Vdc) -44.0, -44.5, -45.0 .. -56.5 NODE.powerMonitor.LWBATVG -44.0 (Vdc) -40.5, -41.0, -41.5 .. -54.0 NODE.protection.1+1.BidirectionalSwitching FALSE TRUE, FALSE NODE.protection.1+1.DetectionGuardTimer 1 (seconds) 0, 0.05, 0.1, 0.5, 1, 2, 3, 4, 5 NODE.protection.1+1.RecoveryGuardTimer 1 (seconds) 0, 0.05, 0.1 .. 10 NODE.protection.1+1.ReversionTime 5.0 (minutes) 0.5, 1.0, 1.5 .. 12.0 NODE.protection.1+1.Revertive FALSE NODE.protection.1+1.VerifyGuardTimer 0.5 (seconds) 0.5, 1 NODE.protection.blsr.RingReversionTime 5.0 (minutes) 0.5, 1.0, 1.5 .. 12.0 NODE.protection.blsr.RingRevertive TRUE NODE.protection.blsr.SpanReversionTime 5.0 (minutes) 0.5, 1.0, 1.5 .. 12.0 NODE.protection.blsr.SpanRevertive TRUE NODE.protection.splitter.ReversionTime 5.0 (minutes) 0.5, 1.0, 1.5 .. 12.0 NODE.protection.splitter.Revertive FALSE NODE.protection.ycable.ReversionTime 5.0 (minutes) 0.5, 1.0, 1.5 .. 12.0 NODE.protection.ycable.Revertive FALSE TRUE, FALSE TRUE, FALSE TRUE, FALSE TRUE, FALSE TRUE, FALSE Cisco ONS 15454 Reference Manual, R8.5.x C-106 78-18106-01 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.security.dataComm.CtcBackplaneIpDisplaySuppression TRUE FALSE, TRUE when isSecureModeSu pportedOnContro lCard TRUE; (NOT SUPPORTED) when isSecureModeSu pportedOnContro lCard FALSE NODE.security.dataComm.DefaultTCCEthernetIP 10.0.0.1 IP Address NODE.security.dataComm.DefaultTCCEthernetIPNetmask 24 (bits) 8, 9, 10 .. 32 NODE.security.dataComm.isSecureModeSupportedOnControlCard TRUE FALSE, TRUE NODE.security.dataComm.LcdBackplaneIpSetting Display Only Allow Configuration, Display Only, Suppress Display when isSecureModeSu pportedOnContro lCard TRUE; (NOT SUPPORTED) when isSecureModeSu pportedOnContro lCard FALSE NODE.security.dataComm.SecureModeLocked FALSE FALSE, TRUE when isSecureModeSu pportedOnContro lCard TRUE; (NOT SUPPORTED) when isSecureModeSu pportedOnContro lCard FALSE Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-107 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.security.dataComm.SecureModeOn (May reboot node) FALSE FALSE, TRUE when isSecureModeSu pportedOnContro lCard TRUE; (NOT SUPPORTED) when isSecureModeSu pportedOnContro lCard FALSE NODE.security.emsAccess.AccessState NonSecure NonSecure, Secure NODE.security.emsAccess.IIOPListenerPort (May reboot node) 57790 (port #) 0 - 65535 NODE.security.grantPermission.ActivateRevertSoftware Superuser Provisioning, Superuser NODE.security.grantPermission.PMClearingPrivilege Provisioning Provisioning, Superuser NODE.security.grantPermission.RestoreDB Superuser Provisioning, Superuser NODE.security.grantPermission.RetrieveAuditLog Superuser Provisioning, Superuser NODE.security.idleUserTimeout.Maintenance 01:00 00:00, 00:01, (hours:mins) 00:02 .. 16:39 NODE.security.idleUserTimeout.Provisioning 00:30 00:00, 00:01, (hours:mins) 00:02 .. 16:39 NODE.security.idleUserTimeout.Retrieve 00:00 00:00, 00:01, (hours:mins) 00:02 .. 16:39 NODE.security.idleUserTimeout.Superuser 00:15 00:00, 00:01, (hours:mins) 00:02 .. 16:39 NODE.security.lanAccess.LANAccess (May disconnect CTC from node) Front & Backplane No LAN Access, Front Only, Backplane Only, Front & Backplane NODE.security.lanAccess.RestoreTimeout 5 (minutes) 0 - 60 Cisco ONS 15454 Reference Manual, R8.5.x C-108 78-18106-01 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.security.legalDisclaimer.LoginWarningMessage WAR NING center>This system is restricted to authorized users for business purposes. Unauthorize d access is a violation of the law. This service may be monitored for administrativ e
and security reasons. By proceeding, you consent to this monitoring. NODE.security.other.DisableInactiveUser FALSE FALSE, TRUE NODE.security.other.InactiveDuration 45 (days) 1, 2, 3 .. 99 when nothing TRUE; 45 when nothing FALSE NODE.security.other.SingleSessionPerUser FALSE TRUE, FALSE NODE.security.passwordAging.EnforcePasswordAging FALSE TRUE, FALSE NODE.security.passwordAging.maintenance.AgingPeriod 45 (days) 20 - 90 NODE.security.passwordAging.maintenance.WarningPeriod 5 (days) 2 - 20 NODE.security.passwordAging.provisioning.AgingPeriod 45 (days) 20 - 90 NODE.security.passwordAging.provisioning.WarningPeriod 5 (days) 2 - 20 NODE.security.passwordAging.retrieve.AgingPeriod 45 (days) 20 - 90 NODE.security.passwordAging.retrieve.WarningPeriod 5 (days) 2 - 20 NODE.security.passwordAging.superuser.AgingPeriod 45 (days) 20 - 90 NODE.security.passwordAging.superuser.WarningPeriod 5 (days) 2 - 20 NODE.security.passwordChange.CannotChangeNewPassword FALSE TRUE, FALSE NODE.security.passwordChange.CannotChangeNewPasswordForNDays 20 (days) 20 - 95 Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-109 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.security.passwordChange.NewPasswordMustDifferFromOldByNCharacters 1 (characters) 1-5 NODE.security.passwordChange.PreventReusingLastNPasswords 1 (times) 1 - 10 NODE.security.passwordChange.RequirePasswordChangeOnFirstLoginToNewAccount FALSE TRUE, FALSE NODE.security.passwordComplexity.IdenticalConsecutiveCharactersAllowed 3 or more 0-2, 3 or more NODE.security.passwordComplexity.MaximumLength 20 20, 80 NODE.security.passwordComplexity.MinimumLength 6 6, 8, 10, 12 NODE.security.passwordComplexity.MinimumRequiredCharacters 1 num, 1 letter & 1 TL1 special 1 num, 1 letter & 1 TL1 special, 1 num, 1 letter & 1 special, 2 each of any 2 of num, upper, lower & TL1 special, 2 each of any 2 of num, upper, lower & special NODE.security.passwordComplexity.ReverseUserIdAllowed TRUE TRUE, FALSE NODE.security.radiusServer.AccountingPort 1813 (port) 0 - 32767 NODE.security.radiusServer.AuthenticationPort 1812 (port) 0 - 32767 NODE.security.radiusServer.EnableNodeAsFinalAuthenticator TRUE FALSE, TRUE NODE.security.serialCraftAccess.EnableCraftPort TRUE TRUE, FALSE NODE.security.shellAccess.AccessState NonSecure Disabled, NonSecure, Secure NODE.security.shellAccess.EnableShellPassword FALSE TRUE, FALSE NODE.security.shellAccess.TelnetPort 23 23 - 9999 NODE.security.snmpAccess.AccessState NonSecure Disabled, NonSecure NODE.security.tl1Access.AccessState NonSecure Disabled, NonSecure, Secure NODE.security.userLockout.FailedLoginsAllowedBeforeLockout 5 (times) 0 - 10 NODE.security.userLockout.LockoutDuration 00:30 (mins:secs) 00:00, 00:05, 00:10 .. 10:00 NODE.security.userLockout.ManualUnlockBySuperuser FALSE TRUE, FALSE NODE.software.AllowDelayedUpgrades FALSE FALSE, TRUE Cisco ONS 15454 Reference Manual, R8.5.x C-110 78-18106-01 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.software.DefaultDelayedUpgrades FALSE FALSE, TRUE when AllowDelayedUp grades TRUE; FALSE when AllowDelayedUp grades FALSE NODE.timing.bits-1.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMM essageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMM essageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMM essageSet N/A NODE.timing.bits-1.AISThreshold SMC PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMM essageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMM essageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMM essageSet N/A Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-111 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.timing.bits-1.Coding B8ZS B8ZS, AMI when FacilityType DS1; HDB3, AMI when FacilityType E1; N/A when FacilityType 2MHz; AMI when FacilityType 64kHz+8kHz NODE.timing.bits-1.CodingOut B8ZS B8ZS, AMI when FacilityTypeOut DS1; HDB3, AMI when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; AMI when FacilityTypeOut 6MHz NODE.timing.bits-1.FacilityType DS1 DS1, 64kHz+8kHz when //.general.Timing Standard SONET; E1, 64kHz+8kHz, 2MHz when //.general.Timing Standard SDH NODE.timing.bits-1.FacilityTypeOut DS1 DS1, 6MHz when //.general.Timing Standard SONET; E1, 6MHz, 2MHz when //.general.Timing Standard SDH Cisco ONS 15454 Reference Manual, R8.5.x C-112 78-18106-01 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.timing.bits-1.Framing ESF ESF, D4 when FacilityType DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz NODE.timing.bits-1.FramingOut ESF ESF, D4 when FacilityTypeOut DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; N/A when FacilityTypeOut 6MHz NODE.timing.bits-1.LBO 0-133 0-133, 134-266, 267-399, 400-533, 534-655 NODE.timing.bits-1.SaBit N/A N/A when FacilityType DS1; 4, 5, 6, 7, 8 when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz NODE.timing.bits-1.State OOS,DSBL D IS, OOS,DSBLD NODE.timing.bits-1.StateOut OOS,DSBL D IS, OOS,DSBLD Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-113 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.timing.bits-2.AdminSSMIn STU PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMM essageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMM essageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMM essageSet N/A NODE.timing.bits-2.AISThreshold SMC PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMM essageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMM essageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMM essageSet N/A NODE.timing.bits-2.Coding B8ZS B8ZS, AMI when FacilityType DS1; HDB3, AMI when FacilityType E1; N/A when FacilityType 2MHz; AMI when FacilityType 64kHz+8kHz Cisco ONS 15454 Reference Manual, R8.5.x C-114 78-18106-01 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.timing.bits-2.CodingOut B8ZS B8ZS, AMI when FacilityTypeOut DS1; HDB3, AMI when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; AMI when FacilityTypeOut 6MHz NODE.timing.bits-2.FacilityType DS1 DS1, 64kHz+8kHz when //.general.Timing Standard SONET; E1, 64kHz+8kHz, 2MHz when //.general.Timing Standard SDH NODE.timing.bits-2.FacilityTypeOut DS1 DS1, 6MHz when //.general.Timing Standard SONET; E1, 6MHz, 2MHz when //.general.Timing Standard SDH NODE.timing.bits-2.Framing ESF ESF, D4 when FacilityType DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz Cisco ONS 15454 Reference Manual, R8.5.x 78-18106-01 C-115 Appendix C Network Element Defaults C.3 Node Default Settings Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.timing.bits-2.FramingOut ESF ESF, D4 when FacilityTypeOut DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; N/A when FacilityTypeOut 6MHz NODE.timing.bits-2.LBO 0-133 0-133, 134-266, 267-399, 400-533, 534-655 NODE.timing.bits-2.SaBit N/A N/A when FacilityType DS1; 4, 5, 6, 7, 8 when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz NODE.timing.bits-2.State OOS,DSBL D IS, OOS,DSBLD NODE.timing.bits-2.StateOut OOS,DSBL D IS, OOS,DSBLD NODE.timing.general.Mode Line External, Line, Mixed Cisco ONS 15454 Reference Manual, R8.5.x C-116 78-18106-01 Appendix C Network Element Defaults C.3.1 Time Zones Table C-21 Node Default Settings (continued) Default Name Default Value Default Domain NODE.timing.general.QualityOfRES RES=DUS NODE.timing.general.ReversionTime 5.0 (minutes) 0.5, 1.0, 1.5 .. 12.0 NODE.timing.general.Revertive TRUE NODE.timing.general.SSMMessageSet Generation 1 Generation 1, Generation 2 when TimingStandard SONET; N/A when TimingStandard SDH NODE.timing.general.TimingStandard SONET PRS
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Warning : Invalid secondary xref table Tagged PDF : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : FrameMaker 7.2 Modify Date : 2010:07:02 06:45:59+05:30 Create Date : 2010:07:01 19:22:30Z Metadata Date : 2010:07:02 06:45:59+05:30 Format : application/pdf Title : 454854r.book Creator : sshamasu Document ID : uuid:76989bf8-f2fe-4d06-84ee-cb42349ace5b Instance ID : uuid:e7d65ee1-834a-4f4a-8e5b-278eaab4c232 Page Count : 828 Concept : Keywords : Doc Type : Author : sshamasu Content Type : Date : 2010-07-01T19:08:19.000-07:00 Access Level : Guest,Customer,Partner Country : US Description : Ia Path : Language : en Secondary Concept :EXIF Metadata provided by EXIF.tools