Cisco Systems A03D1Tbsata Users Manual UCS C220 M3 High Density Small Form Factor Rack Mount Server
A03D1TBSATA to the manual 90184770-1a4e-4838-b2dd-d80c7d7ad20c
2015-01-05
: Cisco-Systems Cisco-Systems-A03D1Tbsata-Users-Manual-203206 cisco-systems-a03d1tbsata-users-manual-203206 cisco-systems pdf
Open the PDF directly: View PDF .
Page Count: 64
Download | |
Open PDF In Browser | View PDF |
Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS 170 WEST TASMAN DR SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.16 OCTOBER 9, 2012 CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 6 CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4 SELECT RAID CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . . . . . . . . . . . . . 22 6 SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 26 8 ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 9 SELECT AC POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . . . . . . . . . . . . . . . . . 33 11 ORDER A TRUSTED PLATFORM MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . 35 13 ORDER OPTIONAL USB 2.0 DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 14 SELECT OPERATING SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 15 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 16 SELECT OPTIONAL VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . 40 17 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 CPUs and DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Memory Population Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Recommended Memory Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Supported DIMM Populations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Low-Voltage DIMM Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 RAID Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 KVM CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Motherboard USB and SD Ports, and RAID Card Backup Location . . . . . . . . . . . . . . . . . . . . 59 TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . Environmental Specifications . . . . . . . . . . . . . . . . . . . Compliance Requirements . . . . . . . . . . . . . . . . . . . . . .... .... .... .... ... ... ... ... .... .... .... .... Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) .... .... .... .... ... ... ... ... .... .... .... .... . . 60 . . 60 . . 62 . . 63 2 OVERVIEW OVERVIEW The Cisco® UCS C220 M3 rack server is designed for performance and density over a wide range of business workloads from web serving to distributed database. Building on the success of the Cisco UCS C200 M2 rack server, the enterprise-class UCS C220 M3 server further extends the capabilities of Cisco’s Unified Computing System portfolio in a 1U form factor with the addition of the Intel® E5-2600 series product family CPUs that deliver significant performance and efficiency gains. In addition, the UCS C220 M3 server provides 16 DIMM slots, up to 8 drives and 2 x 1 GbE LAN-on-motheroard (LOM) ports delivering outstanding levels of density and performance in a compact package. Figure 1 Cisco UCS C220 M3 High-Density SFF Rack Server Front View Rear View Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 3 DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C220 M3 High-Density SFF Rack Server. Chassis Front View 4 1 2 6 5 3 HDD4 7 8 HDD5 9 HDD1 HDD6 HDD2 HDD7 HDD3 HDD8 331682 Figure 2 10 1 Power button/power status LED 6 Power supply status LED 2 Identification button/LED 7 Network link activity LED 3 System status LED 8 Asset tag (serial number) 4 Fan status LED 9 KVM connector (used with KVM cable that provides two USB, one VGA, and one serial connector) 5 Temperature status LED 10 Drives (up to eight hot-swappable 2-5-inch drives) For more information about the KVM cable connection, see KVM CABLE, page 58. 4 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel. Chassis Rear View 1 PSU1 2 3 PCIe1 PCIe2 PSU2 4 5 331683 Figure 3 6 7 8 9 1 Power supplies (up to two) 6 One 10/100/1000 Ethernet dedicated management port 2 Slot 2: Low-profile PCIe slot on riser: 7 Dual 1-Gb Ethernet ports (half-height, half-length, x16 connector, x8 lane width) 3 Slot 1: Standard-profile PCIe slot on riser: (LAN1 and LAN2) 8 USB ports (full-height, half-length, x24 connector, x16 lane width) 4 VGA video connector 9 Rear Identification button/LED 5 Serial port (RJ-45 connector) - - Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 5 BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER, page 9. Table 1 Capabilities and Features Capability/Feature Description Chassis One rack unit (1RU) chassis CPU One or two Intel® E5-2600 series processor family CPUs Chipset Intel® C600 series chipset Memory 16 slots for registered ECC DIMMs (RDIMMs) and load-reduced DIMMs (LRDIMMs) NIC Embedded dual-port Intel i350 PCIe-based Gigabit Ethernet controller, supporting the following: Expansion slots Pre-Execution Boot (PXE boot) ■ iSCSI boot Two PCIe slots (on a riser card) Internal storage devices Cisco Flexible Flash drives ■ ■ One full-height profile, half-length slot with x24 connector and x16 lane ■ One half-height profile, half-length slot with x16 connector and x8 lane Drives are installed into front-panel drive bays that provide hot-pluggable access. ■ Small Form Factor (SFF) drives. Up to eight 2.5-inch SAS or SATA hot-swappable hard disk drives (HDDs) or solid state drives (SSDs) ■ The server also contains one internal USB 2.0 port on the motherboard that you can use with a USB thumb drive for additional storage The server supports one internal Cisco Flexible Flash drive (SD card). ■ ■ Video 4 GB is available for general use The Emulex Pilot 3 Integrated Baseboard Management Controller provides video: ■ Matrox G200e video controller ■ Integrated 2D graphics core with hardware acceleration ■ 6 The SD card is pre-loaded with four virtual drives. The four virtual drives contain, respectively, the Cisco Server Configuration Utility, the Cisco Host Upgrade Utility, the Cisco C-Series server drivers set, and a blank virtual drive on which you can install an OS or a hypervisor Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at 60 Hz ■ 24-bit color depth for all resolutions less than 1600x1200 ■ Up to 256 MB video memory Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) BASE SERVER STANDARD CAPABILITIES and FEATURES Capability/Feature Storage controller Description ■ Embedded RAID (3 Gbs) • Embedded SATA-only RAID controller, supporting up to 4 SATA-only drives (RAID 0, 1, 10) • ROM5 embedded RAID upgrade, supporting up to 8 SAS/SATA drives (RAID 0, 1, 10). SAS and SATA drives can be mixed. • ROM55 embedded RAID upgrade, supporting up to 8 SAS/SATA drives (RAID 0, 1, 10, 5). SAS and SATA drives can be mixed. ■ 2008M-8i Mezzanine Cards (6 Gbs) - two versions • Cisco UCSC RAID SAS 2008M-8i Mezzanine Card, supporting up to 8 SAS/SATA drives supporting RAID 0, 1, 10, 5, and 50. SAS and SATA drives can be mixed. This card has a product ID (PID) of UCSC-RAID-11-C220. • Cisco UCSC RAID SAS 2008M-8i Mezzanine Card, supporting up to eight SAS/SATA drives supporting RAID 0, 1, and 10. SAS and SATA drives can be mixed. This card has a product ID (PID) of UCSC-RAID-MZ-220. ■ Plug-in PCIe Cards (6 Gbs) • LSI MegaRAID SAS 9266-8i 8-port plug-in PCIe RAID RAID controller card (occupies a half-height PCIe slot), supporting RAID levels 0, 1, 10, 5, 6, 50, 60 and up to 8 internal SAS or SATA drives. SAS and SATA drives can be mixed. • LSI MegaRAID SAS 9266CV-8i RAID 8-port PCIe plug-in RAID controller card, supporting RAID 0, 1, 10, 5, 6, 50, and 60 and up to eight internal SAS or SATA drives. SAS and SATA drives can be mixed. Interfaces ■ Rear panel • One RJ45 serial port connector • Two USB 2.0 port connectors • One DB15 VGA connector • Two RJ-45 10/100/1000 Ethernet port connectors • One RJ-45 10/100/1000 Ethernet management port, using Cisco Integrated Management Controller (CIMC) firmware ■ Various PCIe card ports (dependent on which cards are installed) • Converged Network Adapter (CNA) ports • Network Interface Card (NIC) ports • Host Bus Adapter (HBA) ports ■ Front panel • One KVM console connector (supplies two USB, one VGA, and one serial connector) Front Panel A front panel controller provides status indications and control buttons Power subsystem Up to two 450 W 650 W power supplies. One is mandatory; one more can be added for 1 + 1 redundancy. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 7 BASE SERVER STANDARD CAPABILITIES and FEATURES Capability/Feature Description Fans Chassis: ■ Five hot-swappable fans for front-to-rear cooling Power supply: ■ Integrated management processor 8 Each power supply is equipped with a fan. Cisco Integrated Management Controller (CIMC) firmware. Depending on your CIMC settings, the CIMC can be accessed through the 1-Gb Ethernet dedicated management port, the 1-Gb Ethernet LOM ports, or a Cisco P81E or Cisco 1225 virtual interface card (VIC). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C220 M3 High-Density SFF Rack Server: ■ STEP 1 VERIFY SERVER SKU, page 10 ■ STEP 2 SELECT CPU(s), page 11 ■ STEP 3 SELECT MEMORY, page 13 ■ STEP 4 SELECT RAID CONFIGURATION, page 18 ■ STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 22 ■ STEP 6 SELECT PCIe OPTION CARD(s), page 24 ■ STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 26 ■ STEP 8 ORDER POWER SUPPLY, page 29 ■ STEP 9 SELECT AC POWER CORD(s), page 30 ■ STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 33 ■ STEP 11 ORDER A TRUSTED PLATFORM MODULE, page 34 ■ STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL), page 35 ■ STEP 13 ORDER OPTIONAL USB 2.0 DRIVE, page 36 ■ STEP 14 SELECT OPERATING SYSTEM, page 37 ■ STEP 15 SELECT OPERATING SYSTEM MEDIA KIT, page 39 ■ STEP 16 SELECT OPTIONAL VALUE-ADDED SOFTWARE, page 40 ■ STEP 17 SELECT SERVICE and SUPPORT LEVEL, page 41 ■ OPTIONAL STEP - ORDER RACK(s), page 45 ■ OPTIONAL STEP - ORDER PDU, page 46 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 9 CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Verify the product ID (PID) of the server as shown in Table 2. Table 2 PID of the C220 M3 High-Density SFF Rack Base Server Product ID (PID) UCSC-C220-M3S Description UCS C220 M3 SFF, no CPU, memory, HDD, SDD, power supply, SD card, or PCIe cards, with 1 rail kit The Cisco C220 M3 server: ■ Includes one tool-less rail kit ■ Does not include power supply, CPU, memory, hard disk drives (HDDs), solid-state drives (SSDs), SD card, or plug-in PCIe cards. NOTE: Use the steps on the following pages to configure the server with the components that you want to include. 10 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER STEP 2 SELECT CPU(s) The standard CPU features are: ■ Intel E5-2600 series processor family CPUs ■ Intel C600 series chipset ■ Cache size of 10, 15, or 20 MB Select CPUs The available CPUs are listed in Table 3. Table 3 Available Intel CPUs: E5-2600 Series Processor Family CPUs Product ID (PID) Intel Number Clock Freq (GHz) Power (W) Cache Size (MB) Cores QPI Highest DDR3 DIMM Clock Support (MHz)1 UCS-CPU-E5-2690 E5-2690 2.90 135 20 8 8 GT/s 1600 UCS-CPU-E5-2680 E5-2680 2.70 130 20 8 8 GT/s 1600 UCS-CPU-E5-2667 E5-2667 2.90 130 15 6 8 GT/s 1600 UCS-CPU-E5-2665 E5-2665 2.40 115 20 8 8 GT/s 1600 UCS-CPU-E5-2660 E5-2660 2.20 95 20 8 8 GT/s 1600 UCS-CPU-E5-2650 E5-2650 2.00 95 20 8 8 GT/s 1600 UCS-CPU-E5-2650L E5-2650L 1.80 70 20 8 8 GT/s 1600 UCS-CPU-E5-2643 E5-2643 3.30 130 10 4 8 GT/s 1600 UCS-CPU-E5-2640 E5-2640 2.50 95 15 6 7.2 GT/s 1333 UCS-CPU-E5-2630 E5-2630 2.30 95 15 6 7.2 GT/s 1333 UCS-CPU-E5-2630L E5-2630L 2.00 60 15 6 7.2 GT/s 1333 UCS-CPU-E5-2620 E5-2620 2.00 95 15 6 7.2 GT/s 1333 UCS-CPU-E5-2609 E5-2609 2.40 80 10 4 6.4 GT/s 1066 Notes . . . 1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 11 CONFIGURING the SERVER Approved Configurations (1) 1-CPU configurations: ■ Select any one CPU listed in Table 3. (2) 2-CPU Configurations: ■ Select two identical CPUs from any one of the rows of Table 3 on page 11. Caveats 12 ■ You can select either one processor or two identical processors. ■ For optimal performance, select DIMMs with the highest clock speed for a given processor (see Table 3 on page 11). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER STEP 3 SELECT MEMORY The standard memory features are: ■ ■ Figure 4 DIMMs — Clock speed: 1333 or 1600 MHz — Ranks per DIMM: 1, 2, or 4 — Operational voltage: dual voltage capable (1.5 V or 1.35 V) — Registered ECC DDR3 DIMMS (RDIMMS) or load-reduced DIMMS (LRDIMMs) Memory is organized with four memory channels per CPU, with up to two DIMMs per channel, as shown in Figure 4. C220 M3 SFF Memory Organization Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 13 CONFIGURING the SERVER Select DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mirroring option are listed in Table 4. NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data. Table 4 Available DDR3 DIMMs PID Description Voltage Ranks/ DIMM UCS-ML-1X324RY-A 32GB DDR3-1600-MHz LR DIMM/PC3-12800/quad rank/x4/1.35v 1.35 V 4 UCS-MR-1X162RY-A 16GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/x4/1.35v 1.35 V 2 UCS-MR-1X162RX-A 16GB DDR3-1333-MHz RDIMM/PC3-10600/dual rank/x4/1.35v 1.35 V 2 UCS-MR-1X082RY-A 8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/x4/1.35v 1.35 V 2 UCS-MR-1X082RX-A 8GB DDR3-1333-MHz RDIMM/PC3-10600/dual rank/x4/1.35v 1.35 V 2 UCS-MR-1X041RY-A 4GB DDR3-1600-MHz RDIMM/PC3-12800/single rank/x4/1.35v 1.35 V 1 UCS-MR-1X041RX-A 4GB DDR3-1333-MHz RDIMM/PC3-10600/single rank/x4/1.35v 1.35 V 1 Product ID (PID) DIMM Options Memory Mirroring Option N01-MMIRROR 14 Memory mirroring option Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER Approved Configurations (1) 1-CPU configuration without memory mirroring: ■ Select from 1 to 8 DIMMs. Refer to Memory Population Rules, page 50, for more detailed information. (2) 1-CPU configuration with memory mirroring: ■ Select 2, 4, 6, or 8 identical DIMMs. The DIMMs will be placed by the factory as shown in the following table. Total Number of DIMMs ■ CPU 1 DIMM Placement in Channels (for identical DIMMs) Blue Slots Black Slots 2 (A1, B1) 4 (A1,B1); (C1,D1) 6 (A1,B1); (C1,D1) (A2,B2) 8 (A1,B1); (C1,D1) (A2,B2); (C2,D2) Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 14. (3) 2-CPU configuration without memory mirroring: ■ Select from 1 to 8 DIMMs per CPU. Refer to Memory Population Rules, page 50, for more detailed information. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 15 CONFIGURING the SERVER (4) 2-CPU configuration with memory mirroring: ■ Select 2, 4, 6, or 8 identical DIMMs per CPU. The DIMMs will be placed by the factory as shown in the following table. Number of DIMMs per CPU ■ CPU 1 DIMM Placement in Channels (for identical dual-rank DIMMs) Blue Slots Black Slots CPU 2 DIMM Placement in Channels (for identical dual-rank DIMMs) Blue Slots Black Slots 2 (A1, B1) (E1, F1) 4 (A1,B1); (C1,D1) (E1,F1); (G1,H1) 6 (A1,B1); (C1,D1) (A2,B2) (E1,F1); (G1,H1) (E2,F2) 8 (A1,B1); (C1,D1) (A2,B2); (C2,D2) (E1,F1); (G1,H1) (E2,F2); (G2,H2) Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 14. NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs. 16 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER Caveats ■ The server supports registered DIMMs (RDIMMs) or load-reduced DIMMS (LRDIMMs), however, do not mix RDIMMs and LRDIMMs in a server. ■ When using mirroring, DIMMs must be installed in identical pairs across paired DDR3 buses. That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical. However, the DIMMs used in channels A and B and in C and D can be different. ■ UDIMMs and non-ECC DIMMs are not supported. ■ Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must be even for mirroring). ■ When single- and dual-rank DIMMs are populated for 2DPC, always populate the dual rank DIMM in the blue DIMM slot, and the single-rank DIMM in the black DIMM slot (only the 4GB DIMMs are single-rank). ■ By default, all DIMMs run at 1.35 V, which yields 1333-MHz memory speeds. To run the memory DIMMS at 1600 MHz, you need to go into the BIOS or set the policy with UCSM (service profile) to run in Performance Mode. This forces the DIMMs to operate at 1.5 V and yields 1600-MHz speeds, provided: — The DIMMs are 1600-MHz devices — The CPUs chosen support 1600-MHz operation. For more information regarding memory, see CPUs and DIMMs, page 48. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 17 CONFIGURING the SERVER STEP 4 SELECT RAID CONFIGURATION The RAID controller choices are: ■ Embedded RAID (on motherboard) NOTE: If you do not select a mezzanine card, a plug-in PCIe RAID card, or one of the embedded RAID upgrade options, you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10) ■ Mezzanine RAID controller cards ■ Plug-in PCIe RAID controller cards Cisco can provide factory-configured RAID systems depending on the RAID controller chosen and the number of drives ordered. Factory-configured RAID options are listed with each RAID card description. NOTE: The number of RAID groups (logical drives/ virtual drives) supported per controller is as follows: ■ Embedded RAID = 8 drives ■ Cisco UCSC RAID SAS 2008M-8i Mezzanine Card = 16 drives ■ LSI MegaRAID SAS 9266-8i RAID controller card = 64 drives Select RAID Options Select as follows: ■ One embedded RAID upgrade option (see Table 5), or ■ One mezzanine RAID controller (see Table 6), or ■ One PCIe RAID controller card (see Table 7 on page 19) Table 5 Available Embedded RAID Options Product ID (PID) PID Description RAID Controllers UCSC-RAID-ROM5 Onboard RAID, supporting up to 8 SAS or SATA drives. SAS and SATA drives can be mixed. This option supports RAID 0, 1, and 10, and operates at 3 Gb/s. Operating systems supported are Windows and Linux only (no VMware support). UCSC-RAID-ROM55 Onboard RAID, supporting up to 8 SAS or SATA drives. SAS and SATA drives can be mixed. This option supports RAID 0, 1, 10, and 5, and operates at 3 Gb/s. Operating systems supported are Windows and Linux only (no VMware support). 18 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER Table 6 Available Mezzanine Card RAID Options Product ID (PID) PID Description RAID Controllers UCSC-RAID-11-C220 Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 10, 5, and 50 supported), operating at 6 Gbs. ■ Supports up to eight internal SAS or SATA drives. SAS and SATA drives can be mixed. ■ Factory-configured RAID options available: RAID 0, 1, 10, and 5 (see the RAID PIDs section in this table) ■ UCSC-RAID-MZ-220 No data cache backup Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 10 supported), operating at 6 Gbs. ■ Supports up to eight internal SAS or SATA drives. SAS and SATA drives can be mixed. ■ Factory-configured RAID options available: RAID 0, 1, and 10 (see the RAID PIDs section in this table) ■ No data cache backup Table 7 Available Plug-In PCIe Card RAID Options Product ID (PID) PID Description RAID Controllers UCS-RAID-9266NB LSI MegaRAID SAS 9266-8i RAID controller card with no data cache backup (RAID 0, 1, 10, 5, 6, 50, and 60 supported), operating at 6 Gbs. ■ ■ ■ UCS-RAID-9266CV Supports up to eight internal SAS and/or SATA drives. SAS and SATA drives can be mixed. Includes 1 GB of write cache Factory-configured RAID options available: RAID 0, 1, 10, 5, and 6 (see the RAID PIDs section in this table) LSI MegaRAID SAS 9266CV-8i RAID controller card with data cache backup (RAID 0, 1, 10, 5, 6, 50, 60), operating at 6 Gbs. ■ Supports up to eight internal SAS or SATA drives. SAS and SATA drives can be mixed. ■ Includes a 1 GB Transportable Memory Module (TMM) and SuperCap power module for data cache backup ■ Factory-configured RAID options available: RAID 0, 1, 10, 5, and 6 (see the RAID PIDs section in this table) Super Capacitor Option UCS-RAID-CV-SC= LSI CacheVault Power Module for SAS 9266CV Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 19 CONFIGURING the SERVER Table 7 Available Plug-In PCIe Card RAID Options (continued) Product ID (PID) PID Description RAID Configuration Options R2XX-RAID0 Factory preconfigured RAID striping option Enable RAID 0 Setting. Requires a minimum of one hard drive. R2XX-RAID1 Factory preconfigured RAID mirroring option Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity. R2XX-RAID5 Factory preconfigured RAID option Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity. R2XX-RAID6 Factory preconfigured RAID option Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity. R2XX-RAID10 Factory preconfigured RAID option Enable RAID 10 Setting. Requires a even number of drives (minimum of four drives) of the same size, speed, capacity. NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown in Table 5 NOTE: No RAID option can be chosen if you have no drives 20 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER Approved Configurations (1) 1-CPU Configurations Mezzanine cards are not supported for 1-CPU configurations, Therefore, only the following RAID controllers are supported for single-CPU configurations: ■ Embedded RAID ■ LSI MegaRAID SAS 9266-8i ■ LSI MegaRAID SAS 9266CV-8i (2) 2-CPU Configurations Select an embedded RAID option from Table 5, one mezzanine RAID controller from Table 6 on page 19, or one PCIe RAID controller from Table 7 on page 19. You may also select an appropriate optional RAID configuration listed in Table 7 on page 19. Caveats ■ The mezzanine controller is not available for 1-CPU configurations. ■ If you choose a mezzanine card RAID controller or onboard RAID, both the half-height and full-height PCIe card slots are still available for adding optional PCIe cards. ■ The optional PCIe RAID controllers are all half-height PCIe cards. If you choose one of these cards, only the full-height PCIe card slot will be available for adding an optional PCIe card. ■ Note that only a single Cisco VIC card (either the full-height Cisco UCS P81E or the half-height Cisco VIC 1225 PCIe card) is supported and it must be installed in the full-height PCIe slot (slot 1) on riser 1. So take this into account when populating RAID controller cards. ■ You can choose only one RAID controller (embedded RAID, plug-in PCIe RAID controller, or mezzanine card RAID controller). ■ You can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is preconfigured at the factory. The RAID level you choose must be an available RAID choice for the controller selected. RAID levels 50 and 60 are supported, although they are not available as configuration options. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 21 CONFIGURING the SERVER STEP 5 (SSDs) SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES The standard disk drive features are: ■ 2.5-inch small form factor ■ Hot-pluggable ■ Sled-mounted Select Drives The available drives are listed in Table 8. Table 8 Available Hot-Pluggable Sled-Mounted HDDs and SSDs PID Description Drive Type Capacity A03-D1TBSATA 1TB SATA 7.2K RPM SFF HDD SATA 1 TB UCS-HDD900GI2F106 900 GB 6Gb SAS 10K RPM SFF HDD SAS 900 GB A03-D600GA2 600 GB 6Gb SAS 10K RPM SFF HDD SAS 600 GB A03-D500GC3 500 GB SATA 7.2K RPM SFF HDD SATA 500 GB UCS-HDD300GI2F105 300 GB 6Gb SAS 15K RPM SFF HDD SAS 300 GB A03-D300GA2 300 GB 6Gb SAS 10K RPM SFF HDD SAS 300 GB UCS-SD300G0KA2-E 300GB Std Height 15mm SATA SSD SATA 300 GB UCS-SD200G0KA2-E 200GB Std Height 15mm SATA SSD SATA 200 GB UCS-SD100G0KA2-E 100GB Std Height 15mm SATA SSD SATA 100 GB Product ID (PID) HDDs SSDs NOTE: No RAID option can be chosen if you have no drives NOTE: No virtual drive groupings are allowed if you mix HDDs and SSDs. 22 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER Approved Configurations (1) Onboard RAID, Mezzanine Cards, and all Plug-In RAID Controllers ■ If you have not selected an onboard RAID upgrade option (ROM5 or ROM55), a mezzanine card, or a plug-in RAID controller, you may select up to 4 SATA-only drives. ■ Otherwise, select up to eight SAS/SATA drives listed in Table 8. You can mix SAS and SATA drives. Caveats ■ You can mix SATA and SAS drives. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 23 CONFIGURING the SERVER STEP 6 SELECT PCIe OPTION CARD(s) The standard PCie card offerings are: ■ Converged Network Adapters (CNAs) ■ Network Interface Cards (NICs) ■ Host Bus Adapters (HBAs) Select PCIe Option Cards The available PCIe option cards are listed in Table 9. Table 9 Available PCIe Option Cards Product ID (PID) PID Description Card Height Converged Network Adapters (CNAs) N2XX-ACPCI01 Cisco UCS P81E Virtual Interface Card (VIC)/ 2-port 10Gbps Full UCSC-PCIE-BSFP Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI Half UCSC-PCIE-CSC-02 Cisco VIC 1225 Dual Port 10Gb SFP+ CNA Half Network Interface Cards (NICs) N2XX-ABPCI01-M3 Broadcom 5709 Dual Port 1Gb w/TOE iSCSI for M3 Servers Half N2XX-ABPCI03-M3 Broadcom 5709 Quad Port 1Gb w/TOE iSCSI for M3 Servers Half N2XX-AIPCI01 Intel X520 Dual Port 10Gb SFP+ Adapter Half UCSC-PCIE-IRJ45 Intel i350 Quad Port 1Gb Adapter Half UCSC-PCIE-BTG Broadcom 57712 Dual Port 10GBASE-T w/TOE iSCSI Half Host Bus Adapters (HBAs) N2XX-AEPCI03 Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA Half N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half N2XX-AQPCI03 Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA Half N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half 24 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER Approved Configurations (1) No RAID controller plug-in card ■ If you did not choose a plug-in RAID controller (for example, you are using embedded RAID or a mezzanine RAID controller), you can select up to two PCie option cards listed in Table 9. (2) One RAID controller plug-in card ■ If you selected a plug-in PCIe RAID controller, you can select only one of the optional PCIe cards listed in Table 9. NOTE: If a plug-in RAID controller card is installed, any optional PCIe card you select will be installed in the full-height slot. RAID controllers are always installed in the half-height slot. Caveats ■ ■ For 1-CPU systems: — Only the full-height PCIe slot (slot 1) is supported — Neither PCIe slot 2 nor the mezzanine card slot are supported — Only a single VIC card (either the full-height Cisco UCS P81E or the Cisco VIC 1225 PCIe card) is supported and it must be installed in slot 1 (the full-height slot). For 2-CPU systems: — Both PCIe slots and the mezzanine card slot are supported — Only a single VIC card (either the full-height Cisco UCS P81E or the half-height Cisco VIC 1225 PCIe card) is supported and it must be installed in slot 1 (the full height slot). ■ All PCIe cards will fit in either slot, except the Cisco UCS P81E Virtual Interface Card (VIC), which must be installed in the full-height slot (slot 1). ■ Other considerations for the Cisco VIC 1225: ■ — Supports 10G SFP+ optical and copper twinax connections — Requires that the server has CIMC firmware version 1.4(6) or later installed. There is a heartbeat LED on the top of the card that indicates when firmware is active. — To use this card for UCS integration (Cisco UCS Manager mode) with Cisco UCS Manager 2.1(0) or later, the minimum card-firmware and uboot image level is 2.1(0.306). To help ensure that your operating system is compatible with the card you have selected, check the Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 25 CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server. Choose Optional Twinax Cables Table 10 lists the copper twinax cables available for the PCIe cards. You can choose cable lengths of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality. Table 10 Available Twinax Cables Product ID (PID) PID Description SFP-H10GB-CU1M 10GBASE-CU SFP+ Cable (1 M) SFP-H10GB-CU3M 10GBASE-CU SFP+ Cable (3 M) SFP-H10GB-CU5M 10GBASE-CU SFP+ Cable (5 M) SFP-H10GB-ACU7M 10GBASE-CU SFP+ Cable (7 M) SFP-H10GB-ACU10M 10GBASE-CU SFP+ Cable (10 M) Approved Configurations (1) Choose Up to Two Twinax Cables for Each Network Card Ordered ■ You may choose one or two twinax cables for each network card ordered. The cables can be different lengths; however, you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment. Caveats The twinax cables listed in Table 10 can be ordered only for the following PCIe cards: 26 — N2XX-ACPCI01 (Cisco UCS P81E Virtual Interface Card/ 2-port 10Gbps) — UCS-PCIE-BSFP (Broadcom 57712) — N2XX-AEPCI01 (Emulex OCe10102-F) — N2XX-AIPCI01 (Intel Dual Port Ethernet X520) — UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER Choose Optional SFP Modules Optical Cisco SFP+ modules are listed in Table 11. Table 11 Available SFP Modules Product ID (PID) PID Description SFP-10G-SR 10GBASE-SR SFP+ Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring DS-SFP-FC8G-SW 8 Gbit SFP+ Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring Approved Configurations (1) Choose Up to Two SFP+ Modules for Each Network Card Ordered ■ You may choose one or two SFP+ optical modules cables for each network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available. See Figure 5 on page 28 for typical SFP+ and twinax connections to the network cards. Caveats The SFP-10G-SR optical module listed in Table 11 should be ordered only for the following PCIe cards, as they do not come by default with any optical modules: — N2XX-ACPCI01 (Cisco UCS P81E Virtual Interface Card/ 2-port 10Gbps) — UCSC-PCIE-BSFP (Broadcom 57712) — N2XX-ABPCI02 (Broadcom 57711) — N2XX-AEPCI01 (Emulex OCe10102-F) — UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) The DS-SFP-FC8G-SW optical module listed in Table 11 should be ordered only for the following PCIe cards, as they do not come by default with any optical modules: — N2XX-AEPCI05 (Emulex LPe 12002, 8Gb dual-port Fibre Channel HBA) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 27 CONFIGURING the SERVER Figure 5 28 Network Card Connections Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER STEP 8 ORDER POWER SUPPLY The C220 M3 SFF server accommodates two power supplies. A lightly loaded server can operate from one 650 W power supply. A fully loaded server might need to be powered with two 450 W or two 650 W power supplies (see Table 12). Use the power calculator at the following link to determine the needed power based on the options chosen (CPUs, drives, memory, and so on): https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Table 12 Power Supply PIDs Product ID (PID) PID Description UCSC-PSU-450W 450 W power supply UCSC-PSU-650W 650 W power supply NOTE: In a two power supply server, both power supplies must be identical. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 29 CONFIGURING the SERVER STEP 9 SELECT AC POWER CORD(s) Using Table 13, select the appropriate AC power cords. You can select a minimum of no power cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server. Table 13 Available Power Cords Product ID (PID) PID Description Images R2XX-DMYMPWRCORD No power cord (dummy PID to allow for a no power cord option) Not applicable CAB-N5K6A-NA Power Cord, 200/240V 6A, North America Cordset rating: 10 A, 250 V Length: 8.2 ft Connector: IEC60320/C13 Power Cord, NEMA L6-20 250V/20A plug-IEC320/C13 receptacle, North America, Cordset rating 13A, 250V (6.6 feet) (79±2m) Plug: EL312MoldedTwistlock (NEMA L6-20) CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M 30 Connector: EL 701 (IEC60320/C13) 186568 CAB-AC-250V/13A 186570 Plug: NEMA 6-15P Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER Table 13 Available Power Cords Product ID (PID) PID Description SFS-250V-10A-AR Power Cord, SFS, 250V, 10A, Argentina Images 2500 mm Cordset rating: 10 A, 250/500 V MAX Length: 8.2 ft Plug: EL 219 (IRAM 2073) CAB-9K10A-AU 186571 Connector: EL 701 (IEC60320/C13) Power Cord, 250VAC 10A 3112 Plug, Australia Connector: EL 701C (EN 60320/C15) Plug: EL 210 (BS 1363A) 13 AMP fuse Power Cord, SFS, 250V, 10A, China Cordset rating 10A, 250V (2500 mm) Connector: EL 701 (IEC60320/C13) CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC CAB-9K10A-EU Power Cord, 250VAC 10A CEE 7/7 Plug, EU Plug: M2511 Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: VSCC15 SFS-250V-10A-ID 186573 Plug: EL 218 (CCEE GB2009) 186576 SFS-250V-10A-CN 186580 Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Power Cord, SFS, 250V, 10A, India OVE Plug: EL 208 Cordset rating 16A, 250V (2500mm) 187490 Connector: EL 701 SFS-250V-10A-IS Power Cord, SFS, 250V, 10A, Israel EL-212 16A 250V Cordset rating 10A, 250V/500V MAX (2500 mm) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) Connector: EL 701B (IEC60320/C13) 186574 Plug: EL 212 (SI-32) 31 CONFIGURING the SERVER Table 13 Available Power Cords Product ID (PID) PID Description CAB-9K10A-IT Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy Images Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector C15M (EN60320/C15 ) 186575 Plug: I/3G (CEI 23-16) CAB-9K10A-SW Power Cord, 250VAC 10A MP232 Plug, Switzerland Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.5 m) Connector: IEC 60320 C15 186578 Plug: MP232-R CAB-9K10A-UK Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK Plug: EL 210 (BS 1363A) 13 AMP fuse CAB-9K12A-NA Power Cord, 125VAC 13A NEMA 5-15 Plug, North America CAB-JPN-3PIN Power Cord 3PIN, Japan 32 Connector: EL 701C (EN 60320/C15) 186580 Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Image not available Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use Table 14 to order a cable management arm. Table 14 Cable Management Arm Product ID (PID) PID Description UCSC-CMA1 Cable Management Arm for C220 rack servers For more information about the cable management arm, see the Cisco UCS C220 M3 Installation and Service Guide at this URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/C220.pdf Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 33 CONFIGURING the SERVER STEP 11 ORDER A TRUSTED PLATFORM MODULE Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments. The TPM ordering information is listed in Table 15. Table 15 34 Trusted Platform Module Product ID (PID) PID Description UCSX-TPM1-001 Trusted Platform Module Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) You can order one optional 16 GB Cisco Flexible Flash secure digital (SD) card. This SD card contains preloaded software for simplified server operation. The ordering information is listed in Table 16. Table 16 Secure Digital (SD) Card Product ID (PID) PID Description UCSC-SD-16G-C220 16GB SD Card for C220 servers See Figure 6 on page 47 for the location of the SD cards. There are two locations, SD1 and SD2; however, at present only SD1 is supported. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 35 CONFIGURING the SERVER STEP 13 ORDER OPTIONAL USB 2.0 DRIVE You may order one optional USB 2.0 drive. The USB drive ordering information is listed in Table 17. Table 17 USB 2.0 Drive Product ID (PID) PID Description UCS-USBFLSH-S-4GB 4GB Flash USB Drive (shorter length) for all servers except C260 See Figure 6 on page 47 for the location of the USB connector. 36 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER STEP 14 SELECT OPERATING SYSTEM Several operating systems are available from which to choose. Select one of the operating systems shown in Table 18. Table 18 Operating Systems PID Description Product ID (PID) SUSE Linux Enterprise Server SLES-1A SLES/1yr subscription/svcs required/0 media SLES-3A SLES/3yr subscription/svcs required/0 media Red Hat Enterprise Linux RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required RHEL-2S-1G-3A RHEL/2 Socket/1 Guest/3Yr Svcs Required RHEL-2S-4G-1A RHEL/2 Socket/4 Guest/1Yr Svcs Required RHEL-2S-4G-3A RHEL/2 Socket/4 Guest/3Yr Svcs Required RHEL-2S-UG-1A RHEL/2 Socket/U Guest/1Yr Svcs Required RHEL-2S-UG-3A RHEL/2 Socket/U Guest/3Yr Svcs Required RHEL Add-Ons RHEL-HA-2S-1A RHEL Option/High-Availability/2 Socket/1Yr Svcs Required RHEL-RS-2S-1A RHEL Option/Resilient w/Ha /2 Socket/1 Yr Svcs Required RHEL-SFS-2S-1A RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required RHEL-HA-2S-3A RHEL Option/High-Availability/2 Socket/3Yr Svcs Required RHEL-RS-2S-3A RHEL Option/Resilient Storage w/ HA /2 Socket/3 Yr Svcs Reqd RHEL-SFS-2S-3A RHEL Option/Scalable File System/2 Socket/3 Yr Svcs Required Windows Server MSWS-08R2-STHV Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL) MSWS-08R2-ENHV Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL) MSWS-08R2-DCHV2S Windows Svr 2008 R2-2 CPU-Data Center MSWS-08R2-DCHV4S Windows Svr 2008 R2-4 CPU-Data Center VMWare Server VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Required VMW-VS5-STD-2A VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Required Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 37 CONFIGURING the SERVER Table 18 38 Operating Systems (continued) PID Description Product ID (PID) VMW-VS5-STD-3A VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Required VMW-VS5-STD-4A VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Required VMW-VS5-STD-5A VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Required VMW-VS5-ENT-1A VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Required VMW-VS5-ENT-2A VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support Required VMW-VS5-ENT-3A VMware vSphere 5 Enterprise for 1 CPU, 3 Yr Support Required VMW-VS5-ENT-4A VMware vSphere 5 Enterprise for 1 Processor, 4 Year Support Required VMW-VS5-ENT-5A VMware vSphere 5 Enterprise for 1 CPU, 5 Yr Support Required VMW-VS5-ENTP-1A VMware vSphere 5 Enterprise Plus for 1 Processor, 1 Year Support Required VMW-VS5-ENTP-2A VMware vSphere 5 Enterprise Plus for 1 CPU, 2 Yr Support Required VMW-VS5-ENTP-3A VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year Support Required VMW-VS5-ENTP-4A VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Required VMW-VS5-ENTP-5A VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year Support Required Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER STEP 15 SELECT OPERATING SYSTEM MEDIA KIT Select the optional operating system media listed in Table 19. Table 19 OS Media Product ID (PID) PID Description RHEL-6 RHEL 6 Recovery Media Only (Multilingual) SLES-11 SLES 11 media only (multilingual) MSWS-08R2-STHV-RM Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media MSWS-08R2-ENHV-RM Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 39 CONFIGURING the SERVER STEP 16 SELECT OPTIONAL VALUE-ADDED SOFTWARE You can select from a variety of value-added software listed in Table 20. Table 20 40 Value Added Software Product ID (PID) PID Description BMC-SE-4C BMC BladeLogic Standard Edition, 4 Cores, Support Required BMC-SE-6C BMC BladeLogic Standard Edition, 6 Cores, Support Required BMC-SE-8C BMC BladeLogic Standard Edition, 8 Cores, Support Required BMC-SE-10C BMC BladeLogic Standard Edition, 10 Cores, Support Required BMC-AE-4C BladeLogic Advanced Edition, 4 Cores, Support Required BMC-AE-6C BMC BladeLogic Advanced Edition, 6 Cores, Support Required BMC-AE-8C BMC BladeLogic Advanced Edition, 8 Cores, Support Required BMC-AE-10C BMC BladeLogic Advanced Edition, 10 Cores, Support Required BMC-002 BMC BladeLogic CM for Physical Cisco Servers BMC-012 BMC BPPM Per Server VMW-VC5-STD-1A VMware vCenter 5 Standard for 1 Processor, 1 Year, Support Required VMW-VC5-STD-2A VMware vCenter 5 Standard for 1 Processor, 2 Year, Support Required VMW-VC5-STD-3A VMware vCenter 5 Standard for 1 Processor, 3 Year, Support Required VMW-VC5-STD-4A VMware vCenter 5 Standard for 1 Processor, 4 Year, Support Required VMW-VC5-STD-5A VMware vCenter 5 Standard for 1 Processor, 5 Year, Support Required N1K-VLEM-UCS-1 Nexus 1000V License PAK for 1 Virtual Ethernet module N1K-CSK9-UCS-404 Nexus 1000V VSM Virtual Appliance Software Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER STEP 17 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available, as described in this section. Unified Computing Warranty, No Contract If you have noncritical implementations and choose no service contract, the following coverage is supplied: ■ Three-year parts coverage. ■ Next business day (NBD) parts replacement eight hours a day, five days a week. ■ 90-day software warranty on media. ■ Downloads of BIOS, drivers, and firmware updates. ■ UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards. Unified Computing Support Service For support of the entire Cisco Unified Computing System, Cisco offers the Cisco Unified Computing Support Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to the Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world. For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Unified Computing Support Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in Table 21. Table 21 UCS Computing Support Service Product ID (PID) On Site? Description CON-UCS1-C220-M3-W No UC Support 8X5XNBD CON-UCS2-C220-M3-W No UC Support 8X5X4 CON-UCS3-C220-M3-W No UC Support 24x7x4 CON-UCS4-C220-M3-W No UC Support 24x7x2 CON-UCS5-C220-M3-W Yes UC Support 8X5XNBD CON-UCS6-C220-M3-W Yes UC Support 8X5X4 CON-UCS7-C220-M3-W Yes UC Support 24x7x4 CON-UCS8-C220-M3-W Yes UC Support 24x7x2 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 41 CONFIGURING the SERVER Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco Unified Computing Warranty Plus Service. You can choose from several levels of advanced parts replacement coverage, including onsite parts replacement in as little as two hours. Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. See Table 22. Table 22 UCS Computing Warranty Plus Service Product ID (PID) On Site? Description CON-UCW2-C220-M3-W No UC Warranty Plus 8x5x4 CON-UCW3-C220-M3-W No UC Warranty Plus 24x7x4 CON-UCW4-C220-M3-W No UC Warranty Plus 24x7x2 CON-UCW5-C220-M3-W Yes UC Warranty Plus 8X5XNBD CON-UCW6-C220-M3-W Yes UC Warranty Plus 8X5X4 CON-UCW7-C220-M3-W Yes UC Warranty Plus 24x7x4 CON-UCW8-C220-M3-W Yes UC Warranty Plus 24x7x2 Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed. Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements. If your company has a need to control confidential, classified, sensitive, or proprietary data, you might want to consider one of the Drive Retention Services listed in Table 23. NOTE: Cisco does not offer a certified drive destruction service as part of this service. 42 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER Table 23 Drive Retention Service Options Service Description UCS Mission Critical Support Service With Drive Retention UCS Support Service With Drive Retention UCS Warranty Plus With Drive Retention Service Program Name Service Level GSP Service Level Product ID (PID) UC CRIT DR UCMD7 24x7x4 Onsite CON-UCMD7-C220-M3-WSFF UCMD8 24x7x2 Onsite CON-UCMD8-C220-M3-WSFF UCSD1 8x5xNBD CON-UCSD1-C220-M3-WSFF UCSD2 8x5x4 CON-UCSD2-C220-M3-WSFF UCSD3 24x7x4 CON-UCSD3-C220-M3-WSFF UCSD4 24x7x2 CON-UCSD4-C220-M3-WSFF UCSD5 8x5xNBD Onsite CON-UCSD5-C220-M3-WSFF UCSD6 8x5x4 Onsite CON-UCSD6-C220-M3-WSFF UCSD7 24x7x4 Onsite CON-UCSD7-C220-M3-WSFF UCSD8 24x7x2 Onsite CON-UCSD8-C220-M3-WSFF UCWD2 8x5x4 CON-UCWD2-C220-M3-WSFF UCWD3 24x7x4 CON-UCWD3-C220-M3-WSFF UCWD4 24x7x2 CON-UCWD4-C220-M3-WSFF UCWD5 8x5xNBD Onsite CON-UCWD5-C220-M3-WSFF UCWD6 8x5x4 Onsite CON-UCWD6-C220-M3-WSFF UCWD7 24x7x4 Onsite CON-UCWD7-C220-M3-WSFF UCWD8 24x7x2 Onsite CON-UCWD8-C220-M3-WSFF UC SUPP DR UC PLUS DR Mission Critical Support Service This service delivers personalized technical account management, expedited technical support, and expert field support engineering for the Cisco Unified Computing System (UCS). The Mission Critical Support Service provides a designated technical account manager (TAM) who acts as a strategic resource to help ensure that the unified computing environment runs at peak efficiency. If a problem arises that threatens business continuity, the TAM provides crisis management leadership, and your IT staff receives expedited access to Cisco's Technical Assistance Center (TAC). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 43 CONFIGURING the SERVER Mission Critical Support Service is a layered service available for all Cisco data center products already support by a UCS Support Service or SMARTnet service contract. For further information about Cisco Mission Critical Support Service, please consult the Service Description that can be found at the following link: http://www.cisco.com/web/about/doing_business/legal/service_descriptions/index.html or contact your Cisco account Manager. For more service and support information, see this URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html 44 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) OPTIONAL STEP - ORDER RACK(s) OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including the C220 M3 SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in Table 24. Racks are shipped separately from the C220 M3 SFF server. Table 24 Racks and Rack Options Product ID (PID) PID Description RACK-UCS1 Cisco R42610 expansion rack, no side panels RACK-UCS21 Cisco R42610 standard rack, w/side panels RACK-BLANK-001 Filler panels (qty 12), 1U, plastic, toolless RACK-CBLMGT-001 Cable mgt D rings (qty 10), metal RACK-CBLMGT-011 Cable mgt straps (qty 10), Velcro RACK-FASTEN-001 Mounting screws (qty 100), M6 RACK-FASTEN-002 Cage nuts (qty 50), M6 RACK-JOIN-001 Rack joining kit Notes . . . 1. Use these same base PIDs to order spare racks (available only as next-day replacements). For more information about the R42610 rack, see RACKS, page 55. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 45 OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC220 M3 server. This PDU is available in a zero rack unit (RU) style (see Table 24). Table 25 PDU Options Product ID (PID) PID Description RP208-30-2P-U-2 Zero RU PDU For more information about the PDU, see PDUs, page 57. 46 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C220 M3 chassis with the top cover removed is shown in Figure 6. Figure 6 C220 M3 SFF With Top Cover Off 2 3 4 5 6 8 7 9 10 11 SAS1 SAS2 SAS2 SAS1 FAN1 PCIe1 FAN2 CPU1 12 1 PCIe2 14 FAN3 PSU2 FAN4 13 CPU2 15 16 FAN5 PSU1 18 17 1 Drives (hot-swappable, accessed through front panel) 10 Trusted platform module socket on motherboard 2 Drive backplane 11 Standard-profile PCIe riser (PCIe slot 1) 3 SuperCap backup unit mounting location 12 Low-profile PCIe riser (PCIe slot 2) 4 Cooling fans (five) 13 Cisco Flexible Flash SD socket SD2 on PCIe riser 2 5 SCU upgrade ROM header (RAID key). 14 Cisco Flexible Flash SD socket SD1 on PCIe riser 2 6 DIMM slots on motherboard (16) 15 Internal USB port Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 47 SUPPLEMENTAL MATERIAL 7 CPUs and heatsinks (two) 16 Power supplies (two, hot-swappable access through rear panel) 8 Integrated RAID on motherboard, and mini-SAS connectors 17 RTC battery on motherboard 9 Mezzanine RAID card, mini-SAS connectors SAS1 and SAS2 18 Software RAID 5 header (RAID key). CPUs and DIMMs Physical Layout Each CPU has four DIMM channels: ■ CPU1 has channels A, B, C, and D ■ CPU2 has channels E, F, G, and H Each DIMM channel has two banks: bank 1 and bank 2. The blue-colored DIMM banks are for bank 1 and the black-colored are for bank 2. As an example, DIMM slots A1, B1, C1, and D1 belong to bank 1, while A2, B2, C2, and D2 belong to bank 2. Figure 7 shows how banks and channels are physically laid out on the motherboard. The DIMM slots on the right (channels A, B, C, and D) are associated with CPU1, while the DIMM slots on the left (channels E, F, G, and H) are associated with CPU2. The bank 1 (blue) DIMM slots are always located farther away from a CPU than the corresponding bank 2 (black) slots. Bank 1 slots (blue) are populated before bank 2 slots (black). 48 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks C1 C2 D1 D2 CPU1 Front of Server B2 B1 A2 A1 G1 G2 H1 H2 F2 F1 E2 E1 331707 CPU2 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 49 SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server, you should consider the following items: ■ For optimum performance, populate at least one DIMM per memory channel per CPU. If using 4 GB DIMMs, you must populate 2 DIMMs per CPU memory channel. ■ The server supports registered DIMMs (RDIMMs) or load-reduced DIMMS (LRDIMMs), however, do not mix RDIMMs and LRDIMMs in a server. ■ Each channel has two DIMM slots (for example, channel A = slots A1 and A2). ■ — A channel can operate with one or two DIMMs installed. — If a channel has only one DIMM, populate slot 1 first (the blue slot). When both CPUs are installed, populate the DIMM slots of each CPU identically. — Fill blue slots in the channels first: A1, E1, B1, F1, C1, G1, D1, H1 — Fill black slots in the channels second: A2, E2, B2, F2, C2, G2, D2, H2 ■ Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized. ■ Observe the DIMM mixing rules shown in Table 26 Table 26 DIMM Mixing Rules for C220 M3 Server DIMM Parameter Mixed Mix Across a Single Bank? Mix Across Multiple Banks? DIMM Size (4, 8, 16 GB) No—Must be same size in the same bank Yes—Different banks can use different DIMM sizes (as long as all DIMMs in a single bank use the same DIMM size). DIMM Speed (1066, 1333, or 1600 MHz)1 No—Must be same speed in the same bank. No—All DIMMs in the server must be same speed. DIMM Type (R-DIMM) No—All DIMMs in a bank must be same type. No—All DIMMs in the server must be same type. Notes . . . 1. Only 1333 and 1600 MHz DIMMs are currently available for the C220 M3 server. 50 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL Recommended Memory Configuration This section explains the recommended DIMM population order rules for the C220 M3 server. ■ All DIMMs must be DDR3 DIMMs. ■ Do not mix: — DIMMs with different sizes or clock rates in a bank — RDIMMs and LRDIMMs — ECC and non-ECC DIMMs ■ There are blue and black DIMM slots. Populate blue slots first. ■ When single- and dual-rank DIMMs are populated for 2DPC, always populate the dual-rank DIMM in the blue DIMM slot and the single-rank DIMM in the black DIMM slot. Many memory configurations are possible. For best results, follow Table 27 when populating DIMMs. Table 27 Recommended Memory Configurations Total System Memory Size 32 GB 64 GB 96 GB 128 GB CPU 1 DIMMs CPU 2 DIMMs DIMM Max Operating Speed (MHz) Total DIMMs in the System1 — 1600 8 2x8 GB — 1600 4 4x4 GB 4x4 GB 4x4 GB 1600 16 4x8 GB — 4x8 GB — 1600 8 1x32 GB — 1x32GB — 1600 2 4x8 GB 2x8 GB 4x8 GB 2x8 GB 1600 12 3x16 GB — 3x16 GB — 1600 6 4x8 GB 4x4 GB 4x8 GB 4x4 GB 1600 16 1x32 GB 1x16 GB 1x32 GB 1x16 GB 1600 4 4x8 GB 4x8 GB 4x8 GB 4x8 GB 1600 16 4x16 GB — 4x16 GB — 1600 8 1x32 GB 1x32GB 1x32 GB 1x32GB 1600 8 Blue Slots Bank 1 (A1, B1, C1, D1) Black Slots Bank 2 (A2, B2, C2, D2) Blue Slots Bank 1 (E1, F1, G1, H1) Black Slots Bank 2 (E2, F2, G2, H2) 4x4 GB — 4x4 GB 2x8 GB — 4x4 GB Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 51 SUPPLEMENTAL MATERIAL Table 27 Recommended Memory Configurations (continued) Total System Memory Size 192 GB 256 GB 512 GB CPU 1 DIMMs CPU 2 DIMMs DIMM Max Operating Speed (MHz) Total DIMMs in the System1 2x16 GB 1600 12 4x16 GB 4x8 GB 1600 16 1x32 GB 2x32 GB 1x32 GB 1600 6 4x16 GB 4x16 GB 4x16 GB 4x16 GB 1600 16 2x32 GB 2x32 GB 2x32 GB 2x32 GB 1600 8 4x32 GB 4x32 GB 4x32 GB 4x32 GB 1600 16 Blue Slots Bank 1 (A1, B1, C1, D1) Black Slots Bank 2 (A2, B2, C2, D2) Blue Slots Bank 1 (E1, F1, G1, H1) Black Slots Bank 2 (E2, F2, G2, H2) 4x16 GB 2x16 GB 4x16 GB 4x16 GB 4x8 GB 2x32 GB Notes . . . 1. Rows marked in yellow indicate best performance 52 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL Supported DIMM Populations The supported DIMM populations are listed in Table 28. Table 28 Supported DIMM Configurations Total DIMMs for CPU 2 CPU 2 Capacity Total Capacity for 2 CPUs 1 x 8 GB 1 8 GB 16 GB 16 GB 1 x 16 GB 1 16 GB 32 GB 2 8 GB 2 x 4 GB 2 8 GB 16 GB 4 x 4 GB 4 16 GB 4 x 4 GB 4 16 GB 32 GB 2 x 8 GB 2 16 GB 2 x 8 GB 2 16 GB 32 GB 6 x 4 GB 6 24 GB 6 x 4 GB 6 24 GB 48 GB 8 x 4 GB 8 32 GB 8 x 4 GB 8 32 GB 64 GB 4 x 8 GB 4 32 GB 4 x 8 GB 4 32 GB 64 GB 8 x 4 GB 8 32 GB 8 x 4 GB 8 32 GB 64 GB 1 x 32 GB 1 32 GB 1 x 32 GB 1 32 GB 64 GB 5 x 8 GB 5 40 GB 5 x 8 GB 5 40 GB 80 GB 3 x 16 GB 3 48 GB 3 x 16 GB 3 48 GB 96 GB 6 x 8 GB 6 48 GB 6 x 8 GB 6 48 GB 96 GB 4x8 GB + 4x4 GB 8 48 GB 4x8 GB + 4x4 GB 8 48 GB 96 GB 7 x 8 GB 7 56 GB 7 x 8 GB 7 56 GB 112 GB 4 x 16 GB 4 64 GB 4 x 16 GB 4 64 GB 128 GB 8 x 8 GB 8 64 GB 8 x 8 GB 8 64 GB 128 GB 2 x 32 GB 2 64 GB 2 x 32 GB 2 64 GB 128 GB 5 x 16 5 80 GB 5 x 16 5 80 GB 160 GB 4x16 GB + 4x4 GB 8 80 GB 4x16 GB + 4x4 GB 8 80 GB 160 GB 6 x 16 GB 6 96 GB 6 x 16 GB 6 96 GB 192 GB 4x8 GB + 4x16 GB 8 96 GB 4x8 GB + 4x16 GB 8 96 GB 192 GB 7 x 16 GB 7 112 GB 7 x 16 GB 7 112 GB 224 GB 8 x 16 GB 8 128 GB 8 x 16 GB 8 128 GB 256 GB 4 x 32 GB 4 128 GB 4 x 32 GB 4 128 GB 256 GB 8 x 32 GB 8 256 GB 8 x 32 GB 8 256 GB 512 GB Total DIMMs for CPU 1 CPU 1 Capacity 1 x 8 GB 1 8 GB 1 x 16 GB 1 2 x 4 GB CPU 1 DIMMs CPU 2 DIMMs Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 53 SUPPLEMENTAL MATERIAL Low-Voltage DIMM Considerations The C220 M3 server can be ordered with dual-voltage (1.5/1.35 V) DIMMs only. Note the following considerations: ■ Low-voltage DIMMs within the server must have the identical manufacturer, type, speed, and size. ■ Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that this causes the system BIOS to default to standard-voltage operation (Performance Mode). That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage DIMMs. ■ CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage DIMMs operating in Power Saving Mode only, and do not support Performance Mode. RAID Summary The C220 M3 SFF server has an 8-drive backplane. ■ ROM5 and ROM55 embedded RAID upgrade options support up to 8 drives ■ Mezzanine card (UCSC-RAID-11-C220) supports up to 8 drives ■ Mezzanine card (UCSC-RAID-MZ-220) supports up to 8 drives ■ SAS 9266-8i and SAS 9266CV-8i PCIe cards support up to 8 drives NOTE: If you do not select a mezzanine card, a plug-in PCIe RAID card, or one of the embedded RAID upgrade options, you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10) 54 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 8) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: ■ Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in Table 29. Table 29 Cisco R42610 Rack Specifications Parameter Standard Rack Expansion Rack Dimensions (H x W x D) 78.74 x 24 x 43.38 in. (2000 x 610 x 1102 mm) 78.74 x 23.58 x 43.38 in. (2000 x 599 x 1102 mm) Dimensions (H x W x D) with packaging 89 x 33 x 47 in. (2261 x 838 x 1194 mm) 89 x 33 x 47 in. (2261 x 838 x 1194 mm) Distance from front mounting rail to rear mounting rail 29.2 in (741 mm) 29.2 in (741 mm) Weight 299.83 lb (136 kg) 231. 49 lb (105 kg) Weight with packaging 354 lb (161 kg) 284 lb (129 kg) Side panels included Yes No Equipment mounting capacity 42RU 42RU Static load capacity 2100 lb (954 kg) 2100 lb (954 kg) Dynamic load capacity Not applicable Not applicable NOTE: The AC input connector is an IEC 320 C-14 15 A/250 VAC power inlet. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 55 SUPPLEMENTAL MATERIAL Figure 8 Cisco R42610 Rack Front view - door closed 56 Front view - door open Front view - door removed Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician. With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords. The C-series severs accept the zero-rack-unit (0RU) PDU. See Figure 9). Figure 9 Zero Rack Unit PDU (PID = RP208-30-2P-U-2) 1 Breakers 3 C19 plugs 2 Ground connection 4 C13 plugs Cisco RP Series PDU models provide two 20-ampere (A) circuit breakers for groups of receptacles. The effects of a tripped circuit are limited to a receptacle group. Simply press a button to reset that circuit. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 57 SUPPLEMENTAL MATERIAL KVM CABLE The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB ports for a keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server. The KVM cable ordering information is listed in Table 30. Table 30 KVM Cable Product ID (PID) PID Description N20-BKVM KVM cable for B-Series Blade Server console port Figure 10 KVM Cable 1 Connector (to server front panel) 3 VGA connector (for a monitor) 2 DB-9 serial connector 4 Two-port USB connector (for a mouse and keyboard) 58 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL Motherboard USB and SD Ports, and RAID Card Backup Location The C220 M3 SFF motherboard has a general-purpose USB socket, and two SD sockets as shown in Figure 11. The mounting location for the RAID SuperCap data cache power backup module is also shown. Figure 11 Motherboard USB and SD Ports and RAID Card Super Capacitor Location 4 SAS1 SAS2 SAS2 SAS1 FAN1 PCIe1 FAN2 CPU1 2 PCIe2 FAN3 PSU2 FAN4 1 CPU2 3 FAN5 331714 PSU1 1 SD1 socket 3 USB connector 2 SD2 socket 4 SuperCap module mounting location Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 59 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 31 UCS C220 M3 Dimensions and Weight Parameter Value Height 1.7 in. (4.32 cm) Width 16.92 in.(43.0 cm) Depth 28.5 in. (72.4cm) Front Clearance 3 in. (76 mm) Side Clearance 1 in. (25 mm) Rear Clearance 6 in. (152 mm) Weight Maximum (8 HDDs, 2 CPUs, 16 DIMMs, 2 power supplies) 35.6 lbs (16.2 kg) Minimum (1 HDD, 1 CPU, 1 DIMM, 1 power supply) 26.8 lbs (12.1 kg) Bare (0 HDD, 0 CPU, 0 DIMM, 1 power supply) 22 lbs (10 kg) Power Specifications The general power specifications for the C220 M3 SFF server 450 W power supply are listed in Table 32. Table 32 UCS C220 M3 SFF 450 W Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self-ranging, 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal) Maximum AC input current 7.6 A peak at 100 VAC 3.65 A peak at 208 VAC Maximum AC inrush current 11 A Maximum output power for each power supply 450 W Power supply output voltage Main power: 12 VDC Standby power: 12 VDC 60 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) TECHNICAL SPECIFICATIONS Table 32 UCS C220 M3 SFF 450 W Power Supply Specifications Description Specification Power supply efficiency CSCI Platinum NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. The general power specifications for the C220 M3 SFF server 650 W power supply are listed in Table 32. Table 33 UCS C220 M3 LFF 650 W Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self-ranging, 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal) Maximum AC input current 7.6 A peak at 100 VAC 3.65 A peak at 208 VAC Maximum AC inrush current 11 A Maximum output power for the power supply 650 W Power supply output voltage Main power: 12 VDC Standby power: 12 VDC Power supply efficiency CSCI Platinum NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 61 TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C220 M3 server are listed in Table 34. Table 34 UCS C220 M3 Environmental Specifications Parameter Minimum Temperature operating 41 to 104° F (5 to 40° C) derate the maximum temperature by 1°C per every 305m of altitude above sea level Temperature nonoperating –40 to 149°F (–40 to 65°C) Humidity (RH) nonoperating, non-condensing 10 to 90% Altitude operating 0 to 3,000 m (0 to 10,000 ft.) Altitude nonoperating 0 to 12,192 m (0 to 40,000 ft.) Sound Power level, Measure A-weighted per ISO7779 LWAd (Bels)Operation at 73°F (23°C) 5.4 Sound Pressure level, Measure A-weighted per ISO7779 LpAm (dBA)Operation at 73°F (23°C) 37 62 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory compliance requirements for C-Series servers are listed in Table 35. Table 35 UCS C-Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC Safety UL 60950-1 Second Edition CAN/CSA-C22.2 No. 60950-1 Second Edition EN 60950-1 Second Edition IEC 60950-1 Second Edition AS/NZS 60950-1 GB4943 2001 EMC - Emissions 47CFR Part 15 (CFR 47) Class A AS/NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000-3-2 EN61000-3-3 KN22 Class A CNS13438 Class A EMC - Immunity EN55024 CISPR24 EN300386 KN24 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 63 TECHNICAL SPECIFICATIONS 64 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Tagged PDF : Yes Page Count : 64 Page Mode : UseOutlines Format : application/pdf Title : Cisco UCS C220 M3 High-Density Small Form Factor Rack-Mount Server Producer : iText 1.4.1 (by lowagie.com) Keywords : Cisco UCS C-Series Rack-Mount Servers:Products Country : US Date : 10/11/2012 3:05:02 AM Language : en Creator : FrameMaker 9.0 Access Level : Guest,Customer,Partner Concept : Cisco UCS C-Series Rack Servers Modify Date : 2012:10:09 17:56:13Z Ia Path : cisco.com#Products#Cisco Products#Unified Computing and Servers#Cisco UCS C-Series Rack Servers Create Date : 2012:10:09 17:56:13Z Doc Type : Author : micktayl Description : Presales configuration guidelines for Cisco UCS C220 M3 SFF server Content Type : cisco.com#US#preSalesEXIF Metadata provided by EXIF.tools