PA-E3 Serial Port Adapter Installation and Configuration Product Number: PA-E3(=) and PA-2E3(=) Platforms Supported: Cisco 7500 Series, Cisco 7000 Series, VIP2, Cisco 7200 Series, Cisco uBR7200 Series, Cisco 7100 Series, Catalyst 5000 Family Switches Access Registrar, AccessPath, Any to Any, AtmDirector, CCDA, CCDE, CCDP, CCIE, CCNA, CCNP, CCSI, CD-PAC, the Cisco logo, Cisco Certified Internetwork Expert logo, CiscoLink, the Cisco Management Connection logo, the Cisco NetWorks logo, the Cisco Powered Network logo, Cisco Systems Capital, the Cisco Systems Capital logo, Cisco Systems Networking Academy, the Cisco Technologies logo, ConnectWay, ControlStream, Fast Step, FireRunner, GigaStack, IGX, JumpStart, Kernel Proxy, MGX, Natural Network Viewer, NetSonar, Network Registrar, Packet, PIX, Point and Click Internetworking, Policy Builder, Precept, RouteStream, Secure Script, ServiceWay, SlideCast, SMARTnet, StreamView, The Cell, TrafficDirector, TransPath, ViewRunner, VirtualStream, VisionWay, VlanDirector, Workgroup Director, and Workgroup Stack are trademarks; Changing the Way We Work, Live, Play, and Learn, Empowering the Internet Generation, The Internet Economy, and The New Internet Economy are service marks; and Asist, BPX, Catalyst, Cisco, Cisco IOS, the Cisco IOS logo, Cisco Systems, the Cisco Systems logo, the Cisco Systems Cisco Press logo, Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastLink, FastPAD, FastSwitch, IOS, IP/TV, IPX, LightStream, LightSwitch, MICA, NetRanger, Registrar, StrataView Plus, Stratm, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. (9905R) PA-E3 Serial Port Adapter Installation and Configuration Copyright © 1997-1999 Cisco Systems, Inc. All rights reserved. Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 526-4100 Text Part Number: 78-4482-08 Preface This preface describes how to find additional information on the PA-E3 serial port adapter and other Cisco products, services, and documentation. This preface contains the following sections: • • • • • Objectives, page v Organization, page v Related Documentation, page vi Cisco Connection Online, page viii Documentation CD-ROM, page viii Objectives This document describes how to install and configure the PA-E3 serial port adapter (PA-E3[=] and PA-2E3[=]) in the following platforms: • Second-generation Versatile Interface Processor (VIP2) in Cisco 7500 series routers and Cisco 7000 series routers with the Cisco 7000 Series Route Switch Processor (RSP7000) and Cisco 7000 Series Chassis Interface (RSP7000CI). • Cisco 7200 series routers, which consist of the two-slot Cisco 7202, four-slot Cisco 7204 and Cisco 7204VXR, and six-slot Cisco 7206 and Cisco 7206VXR • • • Cisco uBR7200 series universal broadband routers Cisco 7100 series routers, which consist of the Cisco 7120 and Cisco 7140 Catalyst Route Switch Module (RSM)/VIP2 in the Catalyst 5000 family switches Organization This document is organized into the following chapters: Section Title Description Chapter 1 Overview Describes the PA-E3 port adapter and describes its LED displays, cables, and receptacles. Chapter 2 Preparing for Installation Describes safety considerations, tools required, and procedures you should perform before the actual installation. Preface v Related Documentation Section Title Description Chapter 3 VIP2 and the PA-E3 Provides instructions for installing the PA-E3 port adapter on a VIP2 interface processor installed in Cisco 7500 or Cisco 7000 series routers. Chapter 4 Catalyst RSM/VIP2 and the PA-E3 Provides instructions for installing the PA-E3 port adapter on a Catalyst RSM/VIP2 installed in Catalyst 5000 family switches. Chapter 5 Cisco 7200 Series and the PA-E3 Provides instructions for installing the PA-E3 port adapter on a VIP2 interface processor installed in a Cisco 7500 or Cisco 7000 series router. Chapter 6 Cisco uBR7200 Series and the PA-E3 Provides instructions for installing the PA-E3 port adapter in the Cisco uBR7200 series universal broadband router. Chapter 7 Cisco 7100 Series and the PA-E3 Provides information on the PA-E3 port adapter and its use in Cisco 7100 series routers. Chapter 8 Configuring the PA-E3 Interfaces Provides instructions for configuring your port adapter on the supported platforms. The instructions given in this chapter apply to all supported platforms described in this document. Related Documentation Your router and the Cisco IOS software running on it contain extensive features and functionality, which are documented in the following resources: • For Cisco IOS software configuration information and support, refer to the modular configuration and modular command reference publications in the Cisco IOS software configuration documentation set that corresponds to the software release installed on your Cisco hardware. Note You can access Cisco IOS software configuration and hardware installation and maintenance documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com. • For hardware installation and maintenance information on the Cisco 7000 series and Cisco 7500 series routers, and the VIP2, refer to the following publications: — The installation and configuration guide that shipped with your Cisco 7000 series or Cisco 7500 series router — Second-Generation Versatile Interface Processor (VIP2) Installation and Configuration (for VIP2 users only) • For hardware installation and maintenance information on the Catalyst 5000 family switches, and the Catalyst RSM/VIP2, refer to the following publications: — The installation and configuration guide that shipped with your Catalyst 5000 family switches vi PA-E3 Serial Port Adapter Installation and Configuration Related Documentation — Route Switch Module Catalyst VIP2-15 and VIP2-40 Installation and Configuration Note (Document Number 78-4780-01) which shipped with your Catalyst RSM/VIP2. • For hardware installation and maintenance information on Cisco 7100 series routers, refer to the Cisco 7100 Series Installation and Configuration Guide publication that shipped with your Cisco 7100 series router. • For information on setting up a Virtual Private Network, see the Cisco 7100 Series VPN Configuration Guide. • For hardware installation and maintenance information on the Cisco 7200 VXR routers, refer to the Cisco 7200 VXR Installation and Configuration Guide publication that shipped with your Cisco 7200 VXR router. • For hardware installation and maintenance information on the Cisco 7200 routers, refer to the following publications that shipped with your router: — Cisco 7202 Installation and Configuration Guide — Cisco 7204 Installation and Configuration Guide — Cisco 7206 Installation and Configuration Guide • For hardware installation and maintenance information on the Cisco uBR7200 series routers, refer to the Cisco uBR72xx Universal Broadband Router Installation and Configuration Guide that shipped with your Cisco uBR7200 series router. • For international agency compliance, safety, and statutory information for WAN interfaces for the Cisco 7500 series routers, Cisco 7000 series routers, Cisco 7200 series routers, Cisco ubr7200 series routers, and Cisco 7100 series routers, refer to the following publications: — Regulatory Compliance and Safety Information for the Cisco 7500 Series Routers — Regulatory Compliance and Safety Information for the Cisco 7000 Series Routers — Regulatory Compliance and Safety Information for the Cisco 7200 Series Routers — Regulatory Compliance and Safety Information for the Cisco 7100 Series Routers — Regulatory Compliance and Safety Information for the Cisco uBR72xx Universal Broadband Router Note The regulatory compliance and safety information documentation listed above applies to the Catalyst 5000 family switches and the Catalyst RSM/VIP2. • For port adapter hardware and memory configuration guidelines for the Cisco 7200 series routers, refer to the document Cisco 7200 Series Port Adapter Hardware Configuration Guidelines. To view Cisco documentation or obtain general information about the documentation, see the “Cisco Connection Online” section on page viii or the “Related Documentation” section on page vi, or call customer service at 800 553-6387 or 408 526-7208. Customer service hours are 5:00 a.m. to 6:00 p.m. Pacific time, Monday through Friday (excluding Cisco-observed holidays). You can also send e-mail to cs-rep@cisco.com. Preface vii Cisco Connection Online Cisco Connection Online Cisco Connection Online (CCO) is Cisco Systems’ primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services. Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco’s customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files. CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information. You can access CCO in the following ways: WWW: http://www.cisco.com WWW: http://www-europe.cisco.com WWW: http://www-china.cisco.com Telnet: cco.cisco.com Modem: From North America, 408 526-8070; from Europe, 33 1 64 46 40 82. Use the following terminal settings: VT100 emulation; databits: 8; parity: none; stop bits: 1; and connection rates up to 28.8 kbps. For a copy of CCO’s Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com. If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco’s Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com. Documentation CD-ROM Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com. If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments. viii PA-E3 Serial Port Adapter Installation and Configuration C H A P TER 1 Overview This chapter describes the one-port PA-E3 and two-port PA-2E3 E3 serial port adapters. This chapter contains the following sections: • • • • • • Port Adapter Overview, page 1-1 PA-E3 Serial Port Adapter Features, page 1-2 Management Information Base, page 1-3 PA-E3 Port Adapter LEDs, page 1-3 PA-E3 Receptacles and Cables, page 1-4 Interoperability Guidelines for PA-E3 DSUs, page 1-5 Port Adapter Overview The PA-E3 is a single-width, one-port or two-port module that integrates data service unit (DSU) functionality into the Cisco router (see Figure 1-1 and Figure 1-2). The module provides one or two high-speed serial E3 interfaces on: • • • • • Cisco 7100 series routers Cisco 7200 series routers Cisco uBR7200 series routers Second-generation Versatile Interface Processors (VIP2) in all Cisco 7000 series and Cisco 7500 series routers Catalyst RSM/VIP2 in the Catalyst 5000 family switches Note Port adapters have a handle attached, but this handle is occasionally not shown in figures in this publication to allow a full view of detail on the port adapter’s faceplate. Overview 1-1 Port Adapter Overview Figure 1-1 One-Port PA-E3 Serial Port Adapter LK FE RF RL RC TR Figure 1-2 H10607 LL AIS OO F XM RC VR EN AB LE D E3 SERIAL Two-Port PA-2E3 Serial Port Adapter TR H10050 LL AIS OO F LL AIS OO F XM RC VR LK RF RL FE RC RL RF FE RC TR XM VR RC EN AB LE D LK 2E3 SERIAL The one-port PA-E3 provides two network interfaces per VIP2 for Cisco 7000 series and Cisco 7500 series routers and the Catalyst RSM/VIP2 for Catalyst 5000 family switches, and one high-speed interface on the Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers. The two-port PA-2E3 provides four network interfaces per VIP2 for Cisco 7000 series and Cisco 7500 series routers and the Catalyst RSM/VIP2 for Catalyst 5000 family switches, and two high-speed interfaces on the Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers. Serial network interfaces reside on modular port adapters, which provide a direct connection between the high-speed bus in the router and the external networks. The PA-E3 provides a full-duplex synchronous serial E3 interface for transmitting and receiving data at rates of up to 34 megabits per second (Mbps). The port adapter supports both 16- and 32-bit cyclic redundancy checks (CRCs). The default is 16-bit CRCs; to enable 32-bit CRCs, you use a configuration command. For a description of the CRC function, see the “Configuring Cyclic Redundancy Checks” section on page 8-10. Note Although the VIP2 and Catalyst RSM/VIP2 supports online insertion and removal (OIR), individual port adapters do not. To replace port adapters, you must first remove the VIP2 and Catalyst RSM/VIP2 from the chassis, and then replace port adapters as required. The Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers support the OIR of all port adapter types. 1-2 PA-E3 Serial Port Adapter Installation and Configuration PA-E3 Serial Port Adapter Features PA-E3 Serial Port Adapter Features The PA-E3 serial port adapter has the following features: • Single-width port adapter for the VIP2 in all Cisco 7000 series and Cisco 7500 routers, and in Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers • • • • • • • • • • • • • • Single-width port adapter for the Catalyst RSM/VIP2 in the Catalyst 5000 family switches Single- or double-port E3 rate (34 Mbps) connectivity Full-duplex synchronous serial E3 interface High-speed High-Level Data Link Control (HDLC) data Integrated data service unit (DSU) functionality Support for 16- and 32-bit cyclic redundancy checks (CRCs) Support for G.751 framing or bypass framing Support for ATM-DXI, Frame Relay, HDLC, SMDS, and PPP serial encapsulations Support for national service bits Support for E3 MIB (RFC 1407) Support for remote and local loopback HDB3 line coding Scrambling and bandwidth reduction Online insertion and removal (OIR) Management Information Base Management Information Base (MIB) attributes are readable and writable across the Interim Local Management Interface (ILMI) through use of the Simple Network Management Protocol (SNMP). The one-port PA-E3 supports MIB-II (RFC 1213) and the E3 interface MIB (RFC 1407). The two-port PA-2E3 supports MIB-II (RFC 1213) and the E3 interface MIB (RFC 1407). PA-E3 Port Adapter LEDs The one-port PA-E3 port adapter has one status LED and six uplink port status LEDs (RCLK, FERF, OOF, AIS, RL, and LL) for the serial E3 port. (See Figure 1-3.) RL LK RC TR E3 SERIAL H10606 LL S AI OO F XM VR RC FE D LE AB EN RF One-Port PA-E3 Port Adapter LEDs—Partial Front View Shown Figure 1-3 LEDs Overview 1-3 PA-E3 Receptacles and Cables The two-port PA-2E3 port adapter has one status LED and six uplink port status LEDs (RCLK, FERF, OOF, AIS, RL, and LL) for each serial E3 port. (See Figure 1-4.) 2E3 SERIAL H10049 LL RL LK FE RF RC F AI S OO LK FE RF LL RC F AI S OO XM TR VR RC LE AB EN RL Two-Port PA-2E3 Port Adapter LEDs—Partial Front View Shown D Figure 1-4 LEDs After system initialization, the ENABLED LED goes on, indicating that the port adapter has been enabled for operation. The following conditions must be met before the PA-E3 port adapter is enabled: • • The port adapter contains a valid microcode version that has been downloaded successfully. • For the Catalyst 5000 family switches, the port adapter is correctly connected to the Catalyst RSM/VIP2 and is receiving power in the switch. • The bus recognizes the port adapter. For Cisco 7000 and 7500 series routers, the port adapter is correctly connected to the VIP2 and the midplane and is receiving power in the Cisco router. If any of these conditions are not met, or if the initialization fails for other reasons, the ENABLED LED does not go on. Table 1-1 describes the PA-E3 LEDs. Table 1-1 PA-E3 Port Adapter LEDs Name Color State Description ENABLED Green On Indicates that the port adapter is ready. RCLK Green On Indicates that a receive clock has been detected. FERF Yellow On Indicates that Framer detected Far End Receive Failure. OOF Yellow On Indicates that Framer detected Out of Frame. AIS Yellow On Indicates that Framer detected Alarm Indication Signal. RL Yellow On Indicates that port is in remote loopback mode. LL Yellow On Indicates that port is in local loopback mode. Uplink port status PA-E3 Receptacles and Cables The serial interface cable for the PA-E3, which is a 75-ohm coaxial cable, is used to connect your router to a serial E3 network. Serial cables conform to EIA/TIA-612 and EIA/TIA-613 specifications. The serial ports on the PA-E3 are considered to be DTE devices. 1-4 PA-E3 Serial Port Adapter Installation and Configuration Interoperability Guidelines for PA-E3 DSUs On a single PA-E3, there are one or two serial E3 ports, each with two connectors (receive and transmit), where you connect the Cisco 75-ohm coaxial cable. The 75-ohm coaxial cable (Cisco part number CAB-ATM-DS3/E3) for the PA-E3 is available only from Cisco Systems; it is not available from outside commercial cable vendors. The Cisco E3 75-ohm coaxial cable, which comes with an attached ferrite sleeve (see Figure 1-5), is available only in 10-foot (3.05-meter) lengths. The typical maximum distance between stations for E3 transmissions is 1300 feet (396 meters). Note For E3 (75-ohm) connections, you must have ferrite beads on the 75-ohm coaxial cable and EMI decoupling clips on the Rcvr end of the cable (see Figure 1-5) if compliance with European certification standards for emission control is required (EN55022/CISPR22 Class B for radiated emission levels). Figure 1-5 PA-E3 Cables H10314 LK RF FE RC AIS OO F T3 XM RC VR TR EMI decoupler clip Ferrite beads You can test the DTE-to-DCE cable connection by using the loopback dte command. See the “Using the loopback Command to Verify the Physical Interface” section on page 8-20 for more information. Interoperability Guidelines for PA-E3 DSUs The PA-E3 supports several types of integrated DSUs. Table 1-2 lists the feature compatibilities of the PA-E3 DSUs. Table 1-2 Feature Compatibilities of PA-E3 DSUs DSU Full Rate Support Scrambling Support Subrate Support DL3100E Yes No1 Yes1 Kentrox Yes Yes2 Yes2 1 2 DL3100E does not support scrambling. However, the PA-E3 can turn on scrambling in DSU mode 0 for connecting to another PA-E3. The PA-E3 supports either scrambling (in mode 0) or DL3100E subrate, not both at the same time. The PA-E3 supports either scrambling or Kentrox subrate, not both at the same time. Overview 1-5 Interoperability Guidelines for PA-E3 DSUs 1-6 PA-E3 Serial Port Adapter Installation and Configuration C H A P TER 2 Preparing for Installation This chapter describes the general equipment, safety, and site preparation requirements for installing PA-E3 port adapters. • • • • Parts and Tools Required, page 2-1 Software and Hardware Requirements, page 2-2 Safety Guidelines, page 2-3 Compliance Information, page 2-6 Parts and Tools Required You need the following tools and parts to install a port adapter. If you need additional equipment, contact a service representative for ordering information. • PA-E3 serial port adapter and one of the following: — VIP2-15(=) if you are installing only one PA-E3 port adapter; otherwise, we recommend a VIP2-40(=) or VIP2-50(=). — Catalyst RSM/VIP2-15(=) if you are installing only one PA-E3 port adapter; otherwise, we recommend a Catalyst RSM/VIP2-40(=). — Cisco 7100 series router with at least one available port adapter slot. — Cisco 7200 series router with at least one available port adapter slot. — Cisco uBR7200 series router with at least one available port adapter slot. • Cisco 75-ohm coaxial serial interface cables. (The PA-E3’s 75-ohm cables are available only from Cisco Systems; they are not available from outside commercial vendors.) • Number 1 Phillips screwdriver and a 3/16-inch flat-blade screwdriver (for VIP2 and Catalyst RSM/VIP2 installation only). • Your own ESD-prevention equipment or the disposable grounding wrist strap included with all upgrade kits, field-replaceable units (FRUs), and spares. Preparing for Installation 2-1 Software and Hardware Requirements Software and Hardware Requirements Table 2-1 lists the minimum Cisco IOS software release required to use the one-port PA-E3 and two-port PA-2E3 in supported router platforms. Table 2-1 PA-E3 and PA-2E3 Software Requirements Platforms Recommended Minimum Cisco IOS Release Cisco 7000 and Cisco 7500 Series PA-E3 PA-2E3 • With VIP2-15(=) or VIP2-40(=) Cisco IOS Release 11.1(13)CA or a later release of Cisco IOS Release 11.1 CA Cisco IOS Release 11.1(16)CA or a later release of Cisco IOS Release 11.1 CA • With VIP2-50(=) Cisco IOS Release 11.1(14)CA or a later release of Cisco IOS Release 11.1 CA Cisco IOS Release 11.1(16)CA or a later release of Cisco IOS Release 11.1 CA • Cisco 7204VXR and Cisco 7206VXR Cisco IOS Release 12.0(2)XE2 or a later release of Cisco IOS Release 12.0 XE Cisco IOS Release 12.0(3)T or a later release of Cisco IOS Release 12.0 T Cisco IOS Release 12.0(2)XE2 or a later release of Cisco IOS Release 12.0 XE Cisco IOS Release 12.0(3)T or a later release of Cisco IOS Release 12.0 T • Cisco 7204 and Cisco 7206 Cisco IOS Release 11.1(16)CA or a later release of Cisco IOS Release 11.1 CA Cisco IOS Release 11.1(16)CA or a later release of Cisco IOS Release 11.1 CA • Cisco 7202 Cisco IOS Release 11.1(19)CC1 or a later release of Cisco IOS Release 11.1 CC Cisco IOS Release 11.3(4)AA or a later release of Cisco IOS Release 11.3 AA Cisco IOS Release 11.1(19)CC1 or a later release of Cisco IOS Release 11.1 CC Cisco IOS Release 11.3(4)AA or a later release of Cisco IOS Release 11.3 AA Cisco IOS Release 12.0(2)XA or a later release of Cisco IOS Release 12.0 XA Cisco IOS Release 12.0(2)XA or a later release of Cisco IOS Release 12.0 XA Cisco 7200 Series Cisco uBR7200 Series • Cisco uBR7246 and Cisco uBR7223 Cisco 7100 Series • Cisco 7120 series and Cisco 7140 series Cisco IOS Release 12.0(4)XE or a later release of Cisco IOS Release 12.0 XE Cisco IOS Release 12.0(5)T or a later release of Cisco IOS Release 12.0 T Catalyst 5000 Family Switches • With Catalyst RSM/VIP2-15(=) or Catalyst RSM/VIP2-40(=) Cisco IOS Release 12.0(1) or a later release of Cisco IOS Release 12.0 Cisco IOS Release 12.0(1) or a later release of Cisco IOS Release 12.0 Caution The VIP2 requires that the host Cisco 7000 series router have the RSP7000 and RSP7000CI installed. The VIP2 does not operate properly with the Route Processor (RP), Switch Processor (SP), or Silicon Switch Processor (SSP) installed in the host Cisco series router. The PA-E3 is considered a high-bandwidth port adapter; therefore at a minimum, Cisco recommends that the PA-E3 be installed on the VIP2-15 or Catalyst RSM/VIP2-15 motherboard (with 1 MB of SRAM and 8 MB of DRAM). Installation of the PA-E3 on the VIP2-10 (with 512 KB of SRAM and 8 MB of DRAM) is not recommended. 2-2 PA-E3 Serial Port Adapter Installation and Configuration Safety Guidelines Note The VIP2 and Catalyst RSM/VIP2 supports online insertion and removal (OIR), but individual port adapters do not. To replace the port adapters, you must first remove the VIP2 or Catalyst RSM/VIP2 from the chassis and then replace port adapters as required. OIR is supported for port adapters in the Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers. Port adapters have a handle attached, but this handle is occasionally not shown in illustrations in this publication to allow a full view of detail on the port adapter’s faceplate. In the Cisco 7000 series, Cisco 7100 series, Cisco 7500 series, Cisco uBR7200 series routers and Catalyst 5000 family switches, there are no restrictions on slot locations or sequence; however, in the Cisco 7200 series routers, there are specific configuration guidelines that must be observed for high-bandwidth port adapters. For specific Cisco 7200 series hardware configuration information and for memory configuration guidelines for Cisco 7200 series routers, refer to the document Cisco 7200 Series Port Adapter Hardware Configuration Guidelines, which shipped with your Cisco 7200 series chassis and is also available on the Cisco Connection Documentation, Enterprise Series CD-ROM. To determine if your Cisco 7000 series, Cisco 7100 series, Cisco 7500 series, Cisco 7200 series, or Cisco uBR7200 series router, or the Catalyst RSM/VIP2 is compatible with the PA-E3, use the show version command to display the current hardware configuration of the router, including the system software version that is currently loaded and running. You can check the version of the default ROM image by removing the board and checking the ROM labels, or by configuring the interface or system software to boot from ROM, restarting the system, and using the show version command to check the running version. To display the current system software version, use the show version command. In the following example, the running system software is Release 11.1(16)CA. Router> show version Cisco Internetwork Operating System Software IOS (tm) GS Software, Version 11.1(16)CA Synced to mainline version: 11.1(10.5) Copyright (c) 1986-1997 by cisco Systems, Inc. Compiled Thu 22-May-97 14:32 If your system lacks the required system software and microcode, contact a customer service representative for upgrade information. Safety Guidelines The following are safety guidelines that you should follow when working with any equipment that connects to electrical power or telephone wiring. Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device. Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die Preparing for Installation 2-3 Safety Guidelines in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten. Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta). Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d’avertissements figurant dans cette publication, consultez le document Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil. Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information (Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde. Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo. Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten. Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) que acompanha este dispositivo. ¡Advertencia! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo. 2-4 PA-E3 Serial Port Adapter Installation and Configuration Electrical Equipment Guidelines Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning. Electrical Equipment Guidelines Follow these basic guidelines when working with any electrical equipment: • Before beginning any procedures requiring access to the chassis interior, locate the emergency power-off switch for the room in which you are working. • • Disconnect all power and external cables before moving a chassis. • Do not perform any action that creates a potential hazard to people or makes the equipment unsafe. Carefully examine your work area for possible hazards such as moist floors, ungrounded power extension cables, and missing safety grounds. Do not work alone when potentially hazardous conditions exist and never assume that power has been disconnected from a circuit; always check. Telephone Wiring Guidelines Use the following guidelines when working with any equipment that is connected to telephone wiring or to other network cabling: • • Never install telephone wiring during a lightning storm. • Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. • Use caution when installing or modifying telephone lines. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. Preventing Electrostatic Discharge Damage Electrostatic discharge (ESD) damage, which can occur when electronic cards or components are improperly handled, results in complete or intermittent failures. Port adapters and processor modules consist of printed circuit boards that are fixed in metal carriers. Electromagnetic interference (EMI) shielding and connectors are integral components of the carrier. Although the metal carrier helps to protect the board from ESD, use a preventive antistatic strap during handling. The following are guidelines for preventing ESD damage: • • • Always use an ESD wrist or ankle strap and ensure that it makes good skin contact. • When removing a component, use any available ejector levers or captive installation screws to release the bus connectors from the backplane or midplane. Connect the equipment end of the strap to an unfinished chassis surface. When installing a component, use any available ejector levers or captive installation screws to properly seat the bus connectors in the backplane or midplane. These devices prevent accidental removal, provide proper grounding for the system, and help to ensure that bus connectors are properly seated. Preparing for Installation 2-5 Compliance Information • Handle carriers by available handles or edges only; avoid touching the printed circuit boards or connectors. • Place a removed component board-side-up on an antistatic surface or in a static shielding container. If you plan to return the component to the factory, immediately place it in a static shielding container. • Avoid contact between the printed circuit boards and clothing. The wrist strap only protects components from ESD voltages on the body; ESD voltages on clothing can still cause damage. • Never attempt to remove the printed circuit board from the metal carrier. Caution For safety, periodically check the resistance value of the antistatic strap. The measurement should be between 1 and 10 megohms (Mohm). Compliance Information The following sections provide compliance information that applies to the FCC and the PA-E3 serial port adapter, which has been designed to meet these requirements. Modifications to this product that are not authorized by Cisco Systems, Inc., could void the various approvals and negate your authority to operate the product. BABT Compliance The BABT607116 marking on the PA-E3 signifies that it meets United Kingdom directive 607116 and has been designed to BABT standards. The BABT label is located on the top of the PA-E3; Figure 2-1 shows the BABT label for the PA-E3. BABT Label for PA-E3 Serial Port Adapter 607116 H10017 Figure 2-1 ITI-T Compliance ITI-T recommendation G.823 specifies that it is important to restrict jitter gain. Figure 4 of G.823 shows a typical jitter transfer characteristic. (Note that small jitter gain is allowed.) British Standard 6328: Section 8.1 1990 gives the allowable gain as 0.5 dB. The PA-E3’s line mode clocking complies with these sections. TBR24 Compliance When the PA-E3 is in line clocking mode, jitter is not attenuated, and any jitter received is transferred to the line. If input jitter exceeds the limits of TBR24, then output jitter will not meet TBR24 transfer specifications. Line clocking mode is intended for use only where the connection involves a single hop, and where clock timing will not be transferred to other network equipment. When not in line clocking mode, the PA-E3 complies with TBR24 standards. 2-6 PA-E3 Serial Port Adapter Installation and Configuration C H A P TER 3 VIP2 and the PA-E3 This chapter provides information on the PA-E3 serial port adapter and its use on the VIP2 in Cisco 7000 series and Cisco 7500 series routers. This chapter contains the following sections: • • • Overview, page 3-1 Removing a Port Adapter, page 3-4 Installing a Port Adapter, page 3-5 Overview The PA-E3 is used on the VIP2 in Cisco 7000 series and Cisco 7500 series routers and can be installed in either port adapter slot 0 or slot 1 on the VIP2 motherboard. Note You can have up to three E3 serial interfaces on a VIP2 motherboard. Cisco recommends a configuration of one PA-E3 (with one E3 serial interface) and one PA-2E3 (with two serial interfaces) for a total of three E3 serial interfaces per VIP2. Figure 3-1 shows two one-port PA-E3 port adapters installed in port adapter slot 0 and slot 1, on a VIP2-15 or VIP2-40. VIP2 and the PA-E3 3-1 Overview Figure 3-1 VIP2-15 or VIP2-40 with One-Port PA-E3 Port Adapters in Port Adapter Slots 0 and 1 CPU Bus connector Boot ROM U6 SRAM DIMM U5 U4 DRAM SIMMs U2 PA-E3 in port adapter slot 0 D LK LE VR AB EN C R C R TR F R FE L E3 SERIAL D F O O LL VR AB EN AIS LK LE R XM C R C R TR T3 SERIAL F R FE L R XM AIS F O O LL Port adapter handles not shown LK C R F S AI O O H10611 PA-E3 in port adapter slot 1 F R FE L R LL Note Port adapters have a handle attached, but this handle is not shown to allow a full view of detail on each port adapter’s faceplate. 3-2 PA-E3 Serial Port Adapter Installation and Configuration Overview Figure 3-2 shows two one-port E3 port adapters installed in port adapter slots 0 and 1, on a VIP2-50. Figure 3-2 VIP2-50 with One-Port PA-E3 Port Adapters in Port Adapter Slots 0 and 1 CPU Boot ROM Bus connector SRAM daughter card SDRAM DIMM D LK LE VR AB EN C R C R TR F R FE L E3 SERIAL D F O O LL VR AB EN AIS LK LE R XM C R C R TR T3 SERIAL F R FE L R XM AIS F O O LL H11248 PA-E3 in port adapter slot 1 PA-E3 in port adapter slot 0 Port adapter handles not shown LK C R F S AI O O F R FE L R LL Depending on the circumstances, you might need to install a new port adapter on a VIP2 motherboard or replace a failed port adapter in the field. In either case, you need a number 1 Phillips screwdriver, an antistatic mat on which you can place the removed interface processor, and an antistatic container in which you can place a failed port adapter for shipment back to the factory. Note The PA-E3 can be installed on a VIP2-15, VIP2-20, VIP2-40, or VIP2-50 motherboard; however, installation on the VIP2-10 is not recommended. Caution To prevent system problems, do not remove port adapters from the VIP2 motherboard or attempt to install other port adapters on the VIP2 motherboard while the system is operating. To install or replace port adapters, first remove the VIP2 from its interface processor slot. Note Each port adapter circuit board is mounted to a metal carrier and is sensitive to ESD damage. The following procedures should be performed by a Cisco-certified service provider only. The VIP2 supports online insertion and removal (OIR), but individual port adapters do not. To replace port adapters, you must first remove the VIP2 from the chassis and then install or replace port adapters as required. If a blank port adapter is installed on the VIP2 in which you want to install a new port adapter, you must first remove the VIP2 from the chassis and then remove the blank port adapter. VIP2 and the PA-E3 3-3 Removing a Port Adapter When only one port adapter is installed on a VIP2, a blank port adapter must fill the empty slot. This allows the VIP2 and router chassis to conform to electromagnetic interference (EMI) emissions requirements, and encourages air to flow through the chassis properly. If you plan to install a new port adapter, you must first remove the blank port adapter. Removing a Port Adapter Following is the standard procedure for removing any type of port adapter on the VIP2: Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface. Note If you want to install a new port adapter on a VIP2 with a single port adapter, you must first remove the blank port adapter from the port adapter slot in which you want to install the new port adapter. Step 2 For a new port adapter installation or a port adapter replacement, disconnect any interface cables from the ports on the front of the port adapter, although this is not required. You can remove VIP2s with cables attached; however, we do not recommend it. Step 3 To remove the VIP2 from the chassis, follow the steps in the section “Removing a VIP2” in the configuration note Second-Generation Versatile Interface Processor (VIP2) Installation and Configuration, which shipped with your VIP2. Place the removed VIP2 on an antistatic mat. Step 4 Locate the screw at the rear of the port adapter (or blank port adapter) to be replaced. (See Figure 3-3.) This screw secures the port adapter (or blank port adapter) to its slot. Location of Port Adapter Screw—Partial Port Adapter View H3148 Figure 3-3 Screw 3-4 Step 5 Remove the screw that secures the port adapter (or blank port adapter). Step 6 With the screw removed, grasp the handle on the front of the port adapter (or blank port adapter) and carefully pull it out of its slot, away from the edge connector at the rear of the slot. (See Figure 3-4.) PA-E3 Serial Port Adapter Installation and Configuration Installing a Port Adapter Pulling a Port Adapter Out of a Slot—Partial Port Adapter View H3149 Figure 3-4 Step 7 If you removed a port adapter, place it in an antistatic container for safe storage or shipment back to the factory. If you removed a blank port adapter, no special handling is required; however, store the blank port adapter for potential future use. This completes the procedure for removing a new port adapter on a VIP2. Installing a Port Adapter Following is the standard procedure for replacing a port adapter on the VIP2: Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface. Step 2 Remove the new port adapter from its antistatic container and position it at the opening of the slot. Step 3 Carefully align the port adapter carrier between the upper and the lower edges of the port adapter slot, as shown in Figure 3-5. VIP2 and the PA-E3 3-5 Installing a Port Adapter Aligning a Port Adapter in a Port Adapter Slot H3150 Figure 3-5 Carrier Upper edge Lower edge Caution To prevent jamming the carrier between the upper and lower edges of the port adapter slot and to ensure that the edge connector at the rear of the port adapter mates with the connector at the rear of the port adapter slot, make certain that the leading edges of the carrier are between the upper and lower slot edges, as shown in the cutaway in Figure 3-5. Caution To ensure a positive ground attachment between the port adapter carrier and the VIP2 motherboard and port adapter slot, and to ensure that the connectors at the rear of the port adapter and slot mate properly, position the carrier between the upper and lower slot edges, as shown in Figure 3-5. Step 4 3-6 Carefully slide the new port adapter into the port adapter slot until the connector on the port adapter is completely seated in the connector on the motherboard. (See Figure 3-6.) PA-E3 Serial Port Adapter Installation and Configuration Installing a Port Adapter Port Adapter Installed in a Port Adapter Slot—Partial Port Adapter View H3152 Figure 3-6 Step 5 Replace the screw in the rear of the port adapter slot. (See Figure 3-3 for its location.) Do not overtighten this screw. Step 6 To reinstall the VIP2 in the system, follow the steps in the section “Installing a VIP2” in the configuration note Second-Generation Versatile Interface Processor (VIP2) Installation and Configuration, which shipped with your VIP2. Step 7 If the interface cables have been disconnected, reconnect the interface cables to the port adapters. This completes the procedure for installing a port adapter on a VIP2. Proceed to Chapter 8, “Configuring the PA-E3 Interfaces,” for information on how to configure your port adapter interfaces. VIP2 and the PA-E3 3-7 Installing a Port Adapter 3-8 PA-E3 Serial Port Adapter Installation and Configuration C H A P TER 4 Catalyst RSM/VIP2 and the PA-E3 This chapter provides information on the PA-E3 serial port adapter and its use on the Catalyst RSM/VIP2 in the Catalyst 5000 family switches. This chapter contains the following sections: • • • Overview, page 4-1 Removing a Port Adapter, page 4-3 Installing a Port Adapter, page 4-4 Overview The PA-E3 is used on the Catalyst RSM/VIP2 in the Catalyst 5000 family switches and can be installed in either port adapter slot 0 or slot 1 on the Catalyst RSM/VIP2 motherboard. Note You can have up to three E3 serial interfaces on a Catalyst RSM/VIP2 motherboard. Cisco recommends a configuration of one PA-E3 (with one E3 serial interface) and one PA-2E3 (with two serial interfaces) for a total of three E3 serial interfaces. Figure 4-1 shows two one-port PA-E3 port adapters installed in port adapter slot 0 and slot 1, on a Catalyst RSM/VIP2-40. Catalyst RSM/VIP2 and the PA-E3 4-1 Overview Figure 4-1 Catalyst RSM/VIP2-40 with One-Port PA-E3 Port Adapters in Port Adapter Slots 0 and 1 Backplane bus connector Standoff mounting hole Ribbon cables Standoff mounting holes Standoff mounting holes Port adapter securing screw Port adapter securing screw PA-E3 in port adapter slot 0 PA-E3 in port adapter slot 1 LK VR C R C R TR F R FE L E3 SERIAL D F O O LL VR AB EN AIS LK LE R XM C R C R TR F R FE AIS F O O L R XM LL T3 SERIAL 26452 D LE AB EN Port adapter handles not shown Note Port adapters have a handle attached, but this handle is not shown in the figure to allow a full view of detail on each port adapter’s faceplate. Depending on the circumstances, you might need to install a new port adapter on a Catalyst RSM/VIP2 motherboard or replace a failed port adapter in the field. In either case, you need the following items: • • • Number 1 Phillips screwdriver Antistatic mat on which you can place the removed interface processor Antistatic container in which you can place a failed port adapter for shipment back to the factory Caution To prevent system problems, do not remove port adapters from the Catalyst RSM/VIP2 motherboard or attempt to install other port adapters on the Catalyst RSM/VIP2 motherboard while the system is operating. To install or replace port adapters, first remove the Catalyst RSM/VIP2 from its slot. Note Each port adapter circuit board is mounted to a metal carrier and is sensitive to ESD damage. The following procedures should be performed by a Cisco-certified service provider only. The Catalyst RSM/VIP2 supports online insertion and removal (OIR), but individual port adapters do not. To replace port adapters, you must first remove the Catalyst RSM/VIP2 from the chassis and then install or replace port adapters as required. If a blank port adapter is installed on the Catalyst RSM/VIP2 in which you want to install a new port adapter, you must first remove the Catalyst RSM/VIP2 from the chassis and then remove the blank port adapter. 4-2 PA-E3 Serial Port Adapter Installation and Configuration Removing a Port Adapter When only one port adapter is installed on a Catalyst RSM/VIP2, a blank port adapter must fill the empty slot to conform to electromagnetic interference (EMI) emissions requirements and to allow air to flow through the chassis properly. If you plan to install a new port adapter, you must first remove the blank port adapter. Removing a Port Adapter The following is the standard procedure for removing any type of port adapter on the Catalyst RSM/VIP2: Step 1 Attach an antistatic wrist strap between you and an unfinished chassis surface. Note If you want to install a new port adapter on a Catalyst RSM/VIP2 with a single port adapter, you must first remove the blank port adapter from the port adapter slot in which you want to install the new port adapter. Step 2 For a new port adapter installation or a port adapter replacement, disconnect any interface cables from the ports on the front of the port adapter, although this is not required. You can remove a Catalyst RSM/VIP2 with cables attached; however, we do not recommend this action. Step 3 To remove the Catalyst RSM/VIP2 from the chassis, follow the steps in the Route Switch Module Catalyst VIP2-15 and VIP2-40 Installation and Configuration Note (Document Number 78-4780-01), which shipped with your Catalyst RSM/VIP2. Step 4 Place the removed Catalyst RSM/VIP2 on an antistatic mat. Step 5 Locate the screw at the rear of the port adapter (or blank port adapter) to be replaced. (See Figure 4-2.) This screw secures the port adapter (or blank port adapter) to its slot. Location of Port Adapter Screw—Partial Port Adapter View H3148 Figure 4-2 Screw Step 6 Remove the screw that secures the port adapter (or blank port adapter). Step 7 With the screw removed, grasp the handle on the front of the port adapter (or blank port adapter) and carefully pull it out of its slot, away from the edge connector at the rear of the slot. (See Figure 4-3.) Catalyst RSM/VIP2 and the PA-E3 4-3 Installing a Port Adapter Pulling a Port Adapter Out of a Slot—Partial Port Adapter View H3149 Figure 4-3 Step 8 If you removed a port adapter, place it in an antistatic container for safe storage or shipment back to the factory. If you removed a blank port adapter, no special handling is required; however, store the blank port adapter for potential future use. This completes the procedure for removing a new port adapter on a Catalyst RSM/VIP2. Installing a Port Adapter The following is the standard procedure for replacing a port adapter on the Catalyst RSM/VIP2: 4-4 Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface. Step 2 Remove the new port adapter from its antistatic container and position it at the opening of the slot. Step 3 Carefully align the port adapter carrier between the upper and the lower edges of the port adapter slot, as shown in Figure 4-4. PA-E3 Serial Port Adapter Installation and Configuration Installing a Port Adapter Aligning a Port Adapter in a Port Adapter Slot H3150 Figure 4-4 Carrier Upper edge Lower edge Caution To prevent jamming the carrier between the upper and lower edges of the port adapter slot and to ensure that the edge connector at the rear of the port adapter mates with the connector at the rear of the port adapter slot, make certain that the leading edges of the carrier are between the upper and lower slot edges, as shown in the cutaway in Figure 4-5. Caution To ensure a positive ground attachment between the port adapter carrier and the Catalyst RSM/VIP2 motherboard and port adapter slot, and to ensure that the connectors at the rear of the port adapter and slot mate properly, position the carrier between the upper and lower slot edges, as shown in Figure 4-5. Step 4 Carefully slide the new port adapter into the port adapter slot until the connector on the port adapter is completely seated in the connector on the motherboard. (See Figure 4-5.) Catalyst RSM/VIP2 and the PA-E3 4-5 Installing a Port Adapter Port Adapter Installed in a Port Adapter Slot—Partial Port Adapter View H3152 Figure 4-5 Step 5 Replace the screw in the rear of the port adapter slot. (See Figure 4-2 for its location.) Do not overtighten this screw. Step 6 To reinstall the Catalyst RSM/VIP2 in the system, follow the steps in the Route Switch Module Catalyst VIP2-15 and VIP2-40 Installation and Configuration Note (Document Number 78-4780-01), which shipped with your Catalyst RSM/VIP2. Step 7 If the interface cables have been disconnected, reconnect the interface cables to the port adapters. This completes the procedure for installing a port adapter on a Catalyst RSM/VIP2. Proceed to Chapter 8, “Configuring the PA-E3 Interfaces,” for information on how to configure your port adapter interfaces. 4-6 PA-E3 Serial Port Adapter Installation and Configuration C H A P TER 5 Cisco 7200 Series and the PA-E3 This chapter provides information on the PA-E3 serial port adapter and its use in Cisco 7200 series routers. This chapter contains the following sections: • • • Overview, page 5-1 Removing a Port Adapter, page 5-2 Installing a Port Adapter, page 5-3 Overview The PA-E3 can be installed in any available port adapter slot in Cisco 7200 series routers (which consist of the two-slot Cisco 7202, four-slot Cisco 7204 and Cisco 7204VXR, and the six-slot Cisco 7206 and Cisco 7206VXR). Figure 5-1 shows a one-port PA-E3 installed in port adapter slot 3 of a Cisco 7206. Figure 5-1 Cisco 7206 with a PA-E3 in Port Adapter Slot 3 3 2 1 5 0 6 TOKEN RING 4 K RJ4 LIN MII EN 0 LL 1 0 TX 2 RX 4 TX RX 3 TX RX 2 RX TX RX TX EN ETHERNET-10BFL CD LB RC RD TC TD CD LB RC RD TC TD CD LB RC RD TC TD CD LB RC RD TC TD LE AB LK FE RF RL TR AIS OO F XM RC RC D VR LE AB 3 EN EN FAST SERIAL II M FE 0 T T EC O EJ SL IA C M PC EN AB LE D 0 SL O T 1 FAST ETHERNET INPUT/OUTPUT CONTROLLER 5 J-4 R II M N E 5 J-4 R EN 5 R W J-4 R INK O P K 1 O L H10608 1 PA-E3 port adapter 5 D FAST ETHERNET E3 SERIAL Depending on your circumstances, you might need to install a new port adapter in a Cisco 7200 series router or replace a failed port adapter in the field. In either case, no tools are necessary; all port adapters available for the Cisco 7200 series connect directly to the router midplane and are locked into position by a port adapter lever. When removing and replacing a port adapter, you need an antistatic mat onto which you can place a removed port adapter and an antistatic container into which you can place a failed port adapter for shipment back to the factory. Cisco 7200 Series and the PA-E3 5-1 Removing a Port Adapter Note The Cisco 7200 series routers support online insertion and removal(OIR); therefore, you do not have to power down the Cisco 7200 series routers when removing and replacing a port adapter. When a port adapter slot is not in use, a blank port adapter must fill the empty slot to allow the router to conform to EMI emissions requirements and to allow proper airflow across the port adapters. If you plan to install a new port adapter in a slot that is not in use, you must first remove a blank port adapter. Removing a Port Adapter Following is the procedure for removing a port adapter from a Cisco 7200 series router: Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface. Step 2 Place the port adapter lever for the desired port adapter slot in the unlocked position. The port adapter lever remains in the unlocked position. (See Figure 5-2.) Figure 5-2 Placing the Port Adapter Lever in the Unlocked Position—Cisco 7206 Shown 3 2 1 5 0 6 TOKEN RING FAST ETHERNET 4 K RJ4 0 LIN MII 5 D LE AB EN 3 2 3 LINK 1 0 2 1 0 EN 3 AB LE D ETHERNET 10BT 2 CD LB RC RD TC TD CD LB RC RD TC TD CD LB RC RD TC TD CD LB RC RD TC ET ES II 0 D LE AB 5 O PW K R 1O R L J4 IN K R E J4 N 5 M E II N T 0 T EC O EJ SL PC M C IA EN H6596 C 45 R J- FAST ETHERNET INPUT/OUTPUT CONTROLLER PU R M FE SL O T 1 1 TD EN FAST SERIAL Port adapter handle Note: This adapter removal applies to any port or service adapter. Step 3 Port adapter lever (unlocked position) Grasp the handle on the port adapter and pull the port adapter from the midplane, about halfway out of its slot. If you are removing a blank port adapter, pull the blank port adapter completely out of the chassis slot. Note As you disengage the port adapter from the router midplane, OIR administratively shuts down all active interfaces on the port adapter. 5-2 Step 4 With the port adapter halfway out of the slot, disconnect all cables from the port adapter. Step 5 After disconnecting the cables, pull the port adapter from its chassis slot. PA-E3 Serial Port Adapter Installation and Configuration Installing a Port Adapter Caution Always handle the port adapter by the carrier edges and handle; never touch the port adapter’s components or connector pins. (See Figure 5-3.) Figure 5-3 Handling a Port Adapter Metal carrier H6420 Printed circuit board Step 6 Place the port adapter on an antistatic surface with its components facing upward, or in a static shielding bag. If the port adapter will be returned to the factory, immediately place it in a static shielding bag. This completes the procedure for removing a port adapter from a Cisco 7200 series router. Installing a Port Adapter Following is the procedure for installing a new port adapter in a Cisco 7200 series router: Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface. Step 2 Remove the new port adapter from its antistatic container and position it at the opening of the slot. (See Figure 5-4.) Step 3 Use both hands to grasp the port adapter by its metal carrier edges and position the port adapter so that its components face downward. (See Figure 5-3.) Step 4 Align the left and the right edge of the port adapter metal carrier between the guides in the port adapter slot. (See Figure 5-4.) Aligning the Port Adapter Metal Carrier Between the Slot Guides—Cisco 7206 Shown 2 1 0 6 3 TOKEN RING 5 FAST ETHERNET 4 K RJ4 2 0 LIN MII 5 D AB LE EN 3 3 2 2 1 0 LINK 1 0 3 EN AB LE D ETHERNET 10BT ES ET II 45 R J- C PU R M FE AB LE D SL O T 1 1 FAST ETHERNET INPUT/OUTPUT CONTROLLER O PW K R 1O M E II N R E J4 N 5 R L J4 IN 5 K T 0 T EC O EJ SL PC M C IA EN Slot guide H6597 Figure 5-4 Note: This adapter alignment applies to any port or service adapter. Cisco 7200 Series and the PA-E3 5-3 Installing a Port Adapter Step 5 With the metal carrier aligned in the slot guides, gently slide the port adapter halfway into the slot. Caution Do not slide the port adapter all the way into the slot until you have connected all required cables. Trying to do so disrupts normal operation of the router. Step 6 With the port adapter halfway in the slot, connect all required cables to the port adapter. Step 7 After connecting all required cables, carefully slide the port adapter all the way into the slot until the port adapter is seated in the router midplane. Step 8 After seating the port adapter in the router midplane, move the port adapter lever to the locked position. Figure 5-5 shows the port adapter lever in the locked position. Note If the port adapter lever does not move to the locked position, the port adapter is not completely seated in the midplane. Carefully pull the port adapter halfway out of the slot, reinsert it, and move the port adapter lever to the locked position. Figure 5-5 Placing the Port Adapter Lever in the Locked Position—Cisco 7206 Shown 3 2 1 5 0 6 TOKEN RING FAST ETHERNET 4 K RJ4 0 LIN MII 5 D LE AB EN 3 2 3 LINK 1 0 2 1 0 EN 3 AB LE D ETHERNET 10BT 2 CD LB RC RD TC TD CD LB RC RD TC TD CD LB RC RD TC TD CD LB RC RD TC ET ES II 0 D LE AB 5 O PW K R R E J4 N 5 1O R L J4 IN K M E II N T 0 T EC O EJ SL PC M C IA EN H6747 C 45 R J- FAST ETHERNET INPUT/OUTPUT CONTROLLER PU R M FE SL O T 1 1 TD EN FAST SERIAL Port adapter handle Note: This adapter installation applies to any port or service adapter. Port adapter lever (locked position) This completes the procedure for installing a new port adapter in a Cisco 7200 series router. Proceed to Chapter 8, “Configuring the PA-E3 Interfaces,” for information on how to configure your port adapter interfaces. 5-4 PA-E3 Serial Port Adapter Installation and Configuration C H A P TER 6 Cisco uBR7200 Series and the PA-E3 This chapter provides information on the PA-E3 serial port adapter and its use in Cisco uBR7200 series universal broadband routers. This chapter includes the following sections: • • • Overview, page 6-1 Removing a Port Adapter, page 6-2 Installing a Port Adapter, page 6-4 Overview The PA-E3 can be installed in any of the available port adapter slots in Cisco uBR7200 series routers. Figure 6-1 shows a PA-E3 installed in port adapter slot 2 of a Cisco uBR7200 series router. C LK FE R R F L TR 15259 AIS O O F LL XM VR C E3 SERIAL R D LE AB R PA-E3 port adapter Cisco uBR7200 Series with a PA-E3 Port Adapter in Port Adapter Slot 2 EN Figure 6-1 Depending on the circumstances, you might need to install a new port adapter or replace a failed port adapter in a Cisco uBR7200 series router. In either case, no tools are necessary; all port adapters available for the Cisco uBR7200 series routers connect directly to the router midplane and are locked into position by a port adapter retention clip (Cisco uBR7246) or lever (Cisco uBR7223). When removing and replacing a port adapter, you need an antistatic mat onto which you can place a removed port adapter and an antistatic container into which you can place a failed port adapter for shipment back to the factory. Cisco uBR7200 Series and the PA-E3 6-1 Removing a Port Adapter Note The Cisco uBR7200 series routers support online Insertion and Removal (OIR); therefore, you do not have to power down the router when removing and replacing a PA-E3. When a port adapter slot is not in use, blank port adapters must fill empty slots to allow the router to conform to EMI emissions requirements and to allow proper airflow across the port adapters. If you plan to install a new port adapter in a slot that is not in use, you must first remove the blank port adapter. Removing a Port Adapter Following is the procedure for removing a port adapter from a Cisco uBR7200 series router: Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface. Step 2 Unlock the port adapter retaining mechanism. • Figure 6-2 For a Cisco uBR7246, place the port adapter retention clip for the desired port adapter slot in the unlocked position. The retention clip remains in the unlocked position. (See Figure 6-2.) Placing the Port Adapter Retention Clip in the Unlocked Position—Cisco uBR7246 Shown H11518 Port adapters 6-2 PA-E3 Serial Port Adapter Installation and Configuration Port adapter retention clip in unlocked position Removing a Port Adapter • Figure 6-3 For a Cisco uBR7223, place the port adapter lever in the unlocked position. (See Figure 6-3.) Placing the Port Adapter Lever in the Unlocked Position—Cisco uBR7223 Shown Port adapter lever in unlocked position 16217 Port adapters Grasp the handle on the port adapter and pull the port adapter from the router midplane, about halfway out of its slot. If you are removing a blank port adapter, pull the blank port adapter completely out of the chassis slot. Step 3 Note As you disengage the port adapter from the midplane, OIR administratively shuts down all active interfaces on the port adapter. Step 4 With the port adapter halfway out of the slot, disconnect all cables from the port adapter. Step 5 After disconnecting the cables, pull the port adapter from its chassis slot. Caution Always handle the port adapter by the carrier edges and handle; never touch the port adapter’s components or connector pins. (See Figure 6-4.) Figure 6-4 Handling a Port Adapter Metal carrier H6420 Printed circuit board Cisco uBR7200 Series and the PA-E3 6-3 Installing a Port Adapter Step 6 Place the port adapter on an antistatic surface with its components facing upward, or in a static shielding bag. If the port adapter will be returned to the factory, immediately place it in a static shielding bag. This completes the procedure for removing a port adapter from a Cisco uBR7200 series router. Installing a Port Adapter Following is the procedure for installing a port adapter in a Cisco uBR7200 series router: Step 1 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface. Step 2 Use both hands to grasp the port adapter by its metal carrier edges and position the port adapter so that its components are downward. (See Figure 6-4.) Step 3 Align the left and the right edge of the port adapter metal carrier between the guides in the port adapter slot. (See Figure 6-5.) Figure 6-5 Aligning the Port Adapter Metal Carrier Between the Slot Guides Metal carrier PC board Step 4 H11519 Inside slot guide With the metal carrier aligned in the slot guides, gently slide the port adapter halfway into the slot. Caution Do not slide the port adapter all the way into the slot until you have connected all required cables. Trying to do so disrupts normal operation of the router. Step 5 With the port adapter halfway in the slot, connect all required cables to the port adapter. Step 6 After connecting the cables, carefully slide the port adapter all the way into the slot until the port adapter is seated in the router midplane. Step 7 Secure the port adapter: • For a Cisco uBR7246, slide the port adapter retention clip up to the locked position. See Figure 6-6. Note If the retention clip does not slide up to the locked position, the port adapter is not completely seated in the midplane. Carefully pull the port adapter halfway out of the slot, reinsert it, and slide the retention clip up to the locked position. 6-4 PA-E3 Serial Port Adapter Installation and Configuration Installing a Port Adapter Figure 6-6 Placing the Port Adapter Retention Clip in the Locked Position—Cisco uBR7246 Shown H11517 Port adapters • Figure 6-7 Port adapter retention clip in locked position For a Cisco uBR7223, place the port adapter lever in the locked position. (See Figure 6-7.) Placing the Port Adapter Lever in the Locked Position—Cisco uBR7223 Shown Port adapter lever in locked position 16177 Port adapters Note If the port adapter lever does not move to the locked position, the port adapter is not completely seated in the midplane. Carefully pull the port adapter halfway out of the slot, reinsert it, and move the port adapter lever to the locked position. This completes the procedure for installing a port adapter in a Cisco uBR7200 series router. Proceed to Chapter 8, “Configuring the PA-E3 Interfaces,” for information on how to configure your port adapter interfaces. Cisco uBR7200 Series and the PA-E3 6-5 Installing a Port Adapter 6-6 PA-E3 Serial Port Adapter Installation and Configuration C H A P TER 7 Cisco 7100 Series and the PA-E3 This chapter provides information on the PA-E3 serial port adapter and its use in the Cisco 7100 series routers. This chapter contains the following sections: • • • Installation Overview, page 7-1 Removing a Port Adapter, page 7-2 Installing a Port Adapter, page 7-3 Installation Overview The PA-E3 can be installed in port adapter slot 3 in Cisco 7120 series routers and in port adapter slot 4 in Cisco 7140 series routers. Figure 7-1 shows port adapter slot 3 of a Cisco 7120 series router. Figure 7-2 shows port adapter slot 4 of a Cisco 7140 series router. Figure 7-1 Cisco 7120 Series Router—Port Adapter Slot 3 Location Locked ESD plug Unlocked Slot 3 SLOT 0 SLOT 1 PWR ACT ACT 0 FE 0 / 0 I E3 EN TX FE 0/1 LNK LNK 0 1 CONS AUX SYS RDY RX RX CEL CAR ALM 2 7120 - AE3 22133 5 Cisco 7100 Series and the PA-E3 7-1 Removing a Port Adapter Figure 7-2 Cisco 7140 Series Router—Port Adapter Slot 4 Location Locked Unlocked ESD plug Slot 4 AC OK DC OK OTF SLOT 0 SLOT 1 PWR ACT ACT 0 FE 0 / 0 I EN RX RX 155 - MM TX EN CEL CAR ALM FE 0 / 1 RX LNK LNK 0 1 RX 155 - MM CONS AUX AC OK SYS RDY DC OK OTF TX CEL CAR ALM 2 7140 - 2MM3 22134 5 Depending on your circumstances, you might need to install a new port adapter in a Cisco 7100 series router or replace a failed port adapter in the field. All port adapters available for the Cisco 7100 series connect directly to the router and are locked into position by a locking tab with two screws (see Figure 7-1 or Figure 7-2). You need a number 2 Phillips screwdriver to loosen the screws. Note Cisco 7100 series routers support online insertion and removal (OIR); therefore, you do not have to power down the router when removing and replacing a port adapter. When a port adapter slot is not in use, a blank port adapter must fill the empty slot to allow the router to conform to EMI emissions requirements and to allow proper airflow across the port adapters. If you plan to install a new port adapter in a slot that is not in use, you must first remove a blank port adapter. Removing a Port Adapter Follow these steps to remove a port adapter from a Cisco 7100 series router: Step 1 Attach an ESD-preventive wrist strap between you and the chassis. (See Figure 7-1 or Figure 7-2 for the location of the ESD plug.) Step 2 Use a number 2 Phillips screwdriver to loosen the screws on the locking tab; then slide the tab down to the unlocked position. (See Figure 7-1 or Figure 7-2.) Step 3 Grasp the handle on the port adapter and pull the port adapter from the router, about halfway out of its slot. If you are removing a blank port adapter, pull the blank port adapter completely out of the chassis slot. Note As you disengage the port adapter from the router, OIR administratively shuts down all active interfaces on the port adapter. Step 4 With the port adapter halfway out of the slot, disconnect all cables from the port adapter. Step 5 After disconnecting the cables, pull the port adapter from its chassis slot. Caution Always handle the port adapter by the carrier edges and handle; never touch the port adapter’s components or connector pins. (See Figure 7-3.) 7-2 PA-E3 Serial Port Adapter Installation and Configuration Installing a Port Adapter Figure 7-3 Handling a Port Adapter Metal carrier H6420 Printed circuit board Step 6 Place the port adapter on an antistatic surface with its components facing upward, or in a static shielding bag. If the port adapter will be returned to the factory, immediately place it in a static shielding bag. Step 7 Install a blank port adapter or replacement port adapter to maintain proper flow of cooling air across the internal components. For procedures on how to install a port adapter, see the next section, “Installing a Port Adapter”. Note The blank port adapter is available from Cisco Systems as a spare. The blank port adapter product number is MAS-7100-PABLANK. This completes the procedure for removing a port adapter from a Cisco 7100 series router. Installing a Port Adapter Follow these steps to install a new port adapter in a Cisco 7100 series router: Step 1 Attach an ESD-preventive wrist strap between you and the chassis. (See Figure 7-1 for the location of the ESD plug.) Step 2 Ensure that the locking tab is down in the unlocked position. If it is locked, use a number 2 Phillips to loosen the screws; then slide the tab down to the unlocked position. (See Figure 7-1.) Step 3 Remove the new port adapter from its antistatic container and position it at the opening of the slot. Step 4 Use both hands to grasp the port adapter by its metal carrier edges, and position the port adapter so that its components face downward. (See Figure 7-3.) Step 5 Align the left and the right edge of the port adapter metal carrier between the guides in the port adapter slot. (See Figure 7-4.) Step 6 With the metal carrier aligned in the slot guides, gently slide the port adapter halfway into the slot. Caution Do not slide the port adapter all the way into the slot until you have connected all required cables. Trying to do so disrupts normal operation of the router. Cisco 7100 Series and the PA-E3 7-3 Installing a Port Adapter Figure 7-4 Aligning the Single-Width Port Adapter Between the Slot Guides Guides I RCVR EN XMTR RCLK FERF RL FE 0 / 22132 5 AIS OOF LL Step 7 With the port adapter halfway in the slot, connect all required cables to the port adapter. Step 8 After connecting all required cables, carefully slide the port adapter all the way into the slot until the port adapter is seated in the router. Step 9 After seating the port adapter in the router, slide the locking tab up to the locked position and tighten the screws. (Figure 7-1 or Figure 7-2 shows the locking tab in the locked position.) Note If the port adapter lever is not in the locked position, the port adapter is not completely seated in the router. Carefully pull the port adapter halfway out of the slot, reinsert it, and move the port adapter lever to the locked position. This completes the procedure for installing a new port adapter in a Cisco 7100 series router. Proceed to Chapter 8, “Configuring the PA-E3 Interfaces,” to connect the necessary cables to your port adapter. 7-4 PA-E3 Serial Port Adapter Installation and Configuration C H A P TER 8 Configuring the PA-E3 Interfaces To continue your PA-E3 serial port adapter installation, you must configure the E3 interfaces. The instructions that follow apply to all supported platforms. Minor differences between the platforms are noted. This chapter contains the following sections: • • • • • • • Using the EXEC Command Interpreter, page 8-1 Identifying Port Adapter Slot and PA-E3 Interface Port Numbers, page 8-2 Performing a Basic Configuration, page 8-7 Configuration Example, page 8-8 Customizing the PA-E3, page 8-8 Configuring Cyclic Redundancy Checks, page 8-10 Checking the Configuration, page 8-11 If you installed a new PA-E3 or if you want to change the configuration of an existing interface, you must enter configuration mode using the configure command. If you replaced a PA-E3 that was previously configured, the system recognizes the new PA-E3 interfaces and brings each of them up in their existing configuration. After you verify that the new PA-E3 is installed correctly (the enabled LED goes on), use the privileged-level configure command to configure the new interfaces. You will need the following information for your configuration: • • • • Protocols you plan to route on each new interface Internet Protocol (IP) addresses if you are configuring the interfaces for IP routing Plan to use bridging or not on the new interfaces Timing source for each new interface and clock speeds for external timing For a summary of the configuration options available and instructions for configuring interfaces on the PA-E3, refer to the appropriate configuration publications listed in the “Related Documentation” section on page vi. Using the EXEC Command Interpreter You modify the configuration of your router through the software command interpreter called the EXEC (also called enable mode). You must enter the privileged level of the EXEC command interpreter with the enable command before you can use the configure command to configure a new interface or to change the existing configuration of an interface. The system prompts you for a password if one is set. Configuring the PA-E3 Interfaces 8-1 Identifying Port Adapter Slot and PA-E3 Interface Port Numbers The system prompt for the privileged level ends with a pound sign (#) instead of an angle bracket (>). At the console terminal, use the following procedure to enter the privileged level: Step 1 At the user-level EXEC prompt, enter the enable command. The EXEC prompts you for a privileged-level password as follows: Router> enable Password: Step 2 Enter the password (the password is case-sensitive). For security purposes, the password is not displayed. Step 3 When you enter the correct password, the system displays the privileged-level system prompt (#): Router# Proceed to the following section to configure the new interfaces. Identifying Port Adapter Slot and PA-E3 Interface Port Numbers This section describes how to identify port adapter slot and PA-E3 interface port numbers for Cisco 7200 series routers, Cisco 7100 series routers, Cisco uBR7200 series routers, and the VIP2. You can identify interface ports by physically checking the port location on the back of the router or by using software commands to display information about a specific interface or all interfaces in the router. The PA-E3 can be installed in the following slots on the hardware platforms described in this document: • • • VIP2—Port adapter slot 0 and slot 1 • Cisco 7200 series routers—Port adapter slot 1 and slot 2 in a Cisco 7202; port adapter slot 1 through slot 4 in a Cisco 7204 and Cisco 7204VXR; port adapter slot 1 through slot 6 in a Cisco 7206 and Cisco 7206VXR • Cisco uBR7200 series—Port adapter slot 1 and slot 2 in a Cisco uBR7246 and port adapter slot 1 in a Cisco uBR7223 Catalyst RSM/VIP2—Port adapter slot 0 and slot 1 Cisco 7100 series routers—Port adapter slot 3 in a Cisco 7120 series router and port adapter slot 4 in a Cisco 7140 series router Port adapters have a handle attached, but this handle is occasionally not shown in this document to allow a full view of detail on the port adapter’s faceplate. Cisco 7200 Series and Cisco uBR7200 Series Ports Physical port addresses specify the actual physical location of each interface port on a Cisco 7200 series router (see Figure 8-1) or a Cisco uBR7200 series router (see Figure 8-2). This address is composed of a two-part number in the format port adapter slot number/interface port number, as follows: • • 8-2 The first number identifies the chassis slot in which the PA-E3 is installed. The second number identifies the interface port on each PA-E3; the interface port is always numbered as interface 0 for the one-port PA-E3 and 0 or 1 for the two-port PA-2E3. PA-E3 Serial Port Adapter Installation and Configuration Cisco 7200 Series and Cisco uBR7200 Series Ports Interface ports maintain the same address regardless of whether other port adapters are installed or removed from the slot. However, when you move a port adapter to a different slot, the first number in the address changes to reflect the new chassis slot number. In Cisco 7200 series routers, port adapter slots are numbered from the lower left to the upper right, beginning with port adapter slot 1 and continuing through port adapter slot 2 for the Cisco 7202, slot 4 for the Cisco 7204 and Cisco 7204VXR, and slot 6 for the Cisco 7206 and Cisco 7206VXR. Port adapter slot 0 is reserved for the optional Fast Ethernet port on the I/O controller if present. Figure 8-1 shows the port adapter slots and interface ports of a Cisco 7206. The individual interface port numbers always begin with 0. The number of additional ports depends on the number of ports on a port adapter. Note The I/O controller is available with or without a Fast Ethernet port. You can install both I/O controller types in all Cisco 7200 series routers; however, when you install an I/O controller with a Fast Ethernet port in a Cisco 7202, the system software automatically disables the port. For example, the serial port on a one-port PA-E3 in port adapter slot 3 has the address 3/0. (See Figure 8-1.) If the PA-E3 is in port adapter slot 1, this same interface port is numbered 1/0. The serial ports on a two-port PA-2E3 in port adapter slot 3 have the addresses 3/0 and 3/1. Note The PA-E3 is considered a high-bandwidth port adapter; you must observe specific configuration guidelines. Refer to the publication Cisco 7200 Series Port Adapter Hardware Configuration Guidelines, which shipped with your Cisco 7200 series chassis and is also available on the Cisco Connection Documentation, Enterprise Series CD-ROM. Figure 8-1 Cisco 7206 Serial Port Number Example 3 2 1 5 0 6 TOKEN RING 4 K LIN MII EN 0 TX 2 RX 4 TX RX 3 TX RX 2 II M FE 0 SL O T 1 FAST ETHERNET INPUT/OUTPUT CONTROLLER 5 J-4 R 0 T T EC O EJ SL IA C M PC EN AB LE D II M N E 5 J-4 R EN R 5 W J-4 R INK O P K 1 O L H10609 1 0 1 TX RX TX EN CD RX LB RC RD TC TD CD LB RC RD TC TD CD LB RC RD TC TD CD LB RC RD EN TC RJ4 LE AB LK FE RF RL RC F LL AIS OO RC TR VR LE D AB 3 EN XM ETHERNET-10BFL FAST SERIAL TD 5 D FAST ETHERNET E3 SERIAL PA-E3 port adapter (port number 3/0) Figure 8-2 shows the interface ports of a PA-E3 in slot 2 of a Cisco uBR7200 series router. The port adapter slots are numbered slot 1 and slot 2 for the Cisco uBR7246 and slot 1 for the Cisco uBR7223 (slot 0 is always reserved for the Fast Ethernet port on the I/O controller if present). The individual interface port numbers always begin with 0. The number of additional ports depends on the number of ports on a port adapter. Port adapters can occupy any port adapter slot; there are no restrictions. For example, the serial port on a one-port PA-E3 in port adapter slot 1 has the address 1/0. (See Figure 8-2.) If the PA-E3 is in port adapter slot 2, this same interface port is numbered 2/0. The serial ports on a two-port PA-2E3 in port adapter slot 2 have the addresses 2/0 and 2/1. Configuring the PA-E3 Interfaces 8-3 Identifying Port Adapter Slot and PA-E3 Interface Port Numbers R C LK FE R R F L TR VR C 15260 AIS O O F LL R E3 SERIAL XM AB LE D PA-E3 port adapter (port number 1/0) PA-E3 Interface Port Address Example—Cisco uBR7246 Shown EN Figure 8-2 You can identify interface ports by physically checking the port adapter/interface port location on the back of the router or by using software commands to display information about a specific interface or all interfaces in the router. VIP2 Ports In the router, physical port addresses specify the actual physical location of each interface port on the router interface processor end. (See Figure 8-3.) Each address is composed of a three-part number in the format interface processor slot number/port adapter number/interface port number, as follows: • The first number identifies the chassis slot in which the VIP2 is installed (as shown in the sample system in Figure 8-3). • • The second number identifies the physical port adapter slot on the VIP2, and is either 0 or 1. The third number identifies the interface port on each E3 serial port adapter, which is always numbered as interface 0 for the one-port PA-E3 and 0 or 1 for the two-port PA-2E3. Note Although the processor slots in the 7-slot Cisco 7000 and Cisco 7507 and 13-slot Cisco 7513 are vertically oriented and the slots in the 5-slot Cisco 7010 and Cisco 7505 are horizontally oriented, all models use the same method for slot and port numbering. Interface ports on the VIP2 maintain the same address regardless of whether other interface processors are installed or removed. However, when you move a VIP2 to a different slot, the first number in the address changes to reflect the new chassis slot number. Figure 8-3 shows the port adapter slots and interface ports of a sample Cisco 7505 system. On the VIP2, the first port adapter slot number is always 0. The second port adapter slot number is always 1. The individual interface port numbers always begin with 0. The number of additional ports depends on the number of ports on a port adapter. For example, the serial port on a one-port PA-E3 in the first port adapter slot in chassis slot 3 is numbered 3/0/0. (See Figure 8-3.) If the PA-E3 is in port adapter slot 1, this same port is numbered 3/1/0. The serial ports on a two-port PA-2E3 in the first port adapter slot in chassis slot 3 are numbered 3/0/0 and 3/0/1. Port adapters can occupy either port adapter slot; there are no restrictions. 8-4 PA-E3 Serial Port Adapter Installation and Configuration Catalyst RSM/VIP2 Ports Cisco 7505 Serial Port Number Example CP U ROUTE SWITCH PROCESSOR CO NS OL E HA LT PA-E3 (port numbers 3/1/0) SL SLO OT T 0 1 NO RM AL EJ EC T PA-E3 (port number 3/0/0) RE SE T Figure 8-3 F OO LL XM TR FE RF RL Slot 3 LL AIS OO F AIS RC VR RC D LE AB EN LK RF RL FE XM TR RC D VR LE AB RC EN LK E3 SERIAL E3 SERIAL Slot 2 Slot 1 Interface processor slots H10610 Slot 0 You can identify interface ports by physically checking the slot/port-adapter/interface port location on the back of the router or by using show commands to display information about a specific interface or all interfaces in the router. Catalyst RSM/VIP2 Ports In the Catalyst RSM/VIP2, each port adapter address is composed of a two-part number in the format port adapter number/interface port number, as follows: • The first number identifies the physical port adapter slot on the Catalyst RSM/VIP2, and is either 0 or 1. • The second number identifies the interface port on each E3 serial port adapter, which is always numbered as interface 0 for the one-port PA-E3 and 0 or 1 for the two-port PA-2E3. Figure 8-4 shows the port adapters on a Catalyst RSM/VIP2 installed in a Catalyst 5509 switch. The first port adapter slot number is always 0. The second port adapter slot number is always 1. The individual interface port numbers always begin with 0. The number of additional ports depends on the number of ports on a port adapter. For example, the serial port on a one-port PA-E3 in the first port adapter slot is numbered 0/0. (See Figure 8-4.) If the PA-E3 is in port adapter slot 1, this same port is numbered 1/0. The serial ports on a two-port PA-2E3 in the first port adapter slot are numbered 0/0 and 0/1. Port adapters can occupy either port adapter slot; there are no restrictions. Configuring the PA-E3 Interfaces 8-5 Identifying Port Adapter Slot and PA-E3 Interface Port Numbers Figure 8-4 Serial Port Adapters in the Catalyst 5509 WS-x5530 EM S ST U SY AT ST N VE FA 2 PS 1 100% ET TI ES AC T R WS-U5531-FETX 1 O SL 1 T PORT 1 LINK PCMCIA Load MDIX 10/100Mbps LINK AUX Switch 10/100 FAST ETHERCHANNEL EM S ST U SY AT ST 2 PORT 2 10/100Mbps SL CONSOLE MDIX 0 O PS SUPERVISOR ENGINE I I I WS-x5530 N FA 2 PS 1 PS VE 100% ET TI ES AC T R WS-U5531-FETX 1 O SL T PORT 1 CONSOLE PORT 2 MDIX 0 O 10/100Mbps SL SUPERVISOR ENGINE I I I LINK PCMCIA Load MDIX 10/100Mbps LINK AUX Switch TU S 10/100 FAST ETHERCHANNEL ST A 3 FAST ETHERNET SWITCHING MODULE Versatile Interface Processor with port adapters 1 US 2 3 AT 4 5 6 EN 5 7 8 TXR V RC LK RF RC FE RL TR E3 SERIAL D LE XM LK AB EN VR UTP LL 11 12 E3 SERIAL XM AIS OOF CIA CPU LE AB EN M PC ROUTE SWITCH MODULE RF L R FE E3 T HAL D AT ST RC TR RC E3 US 6 10 9 MODULE D LE AB AIS OOF Route Switch Module 4 ST FAST ETHERNET SWITCHING A IC M 0 1 T O SL 0 T O SL NEL AN CH LL X AN CH TX RX T PC 1 NEL ET RES LE AU NSO TX CO RX EC EJ 1 US 7 2 AT 3 4 5 ST FAST ETHERNET SWITCHING 8 1 2 9 10 11 12 4 5 6 7 8 9 10 11 12 3 4 5 6 7 8 9 10 11 12 MODULE 1 US AT 2 ST FAST ETHERNET SWITCHING 8 3 ST FAST ETHERNET SWITCHING 7 MODULE S U AT 9 6 MODULE o o FAN OK OUTPUT FAIL AC OK FAN OK OUTPUT FAIL 26453 AC OK You can identify interface ports by physically checking the port-adapter/interface port location on the back of the router or by using show commands to display information about a specific interface or all interfaces in the router. Cisco 7100 Series Ports In the Cisco 7100 series routers, the slot number is the location in the chassis where the interface resides and the port number is the physical port. Interfaces in the Cisco IOS software are identified by a type, slot number, and port number. For example, serial 3/1 indicates port 1 on the serial port adapter in slot 3. Slots in the Cisco 7120 series routers are numbered as shown in Figure 8-5. The fixed LAN interface is slot 0, the fixed WAN interface is slot 1, and the modular port adapter interface is slot 3. Slots 2 and 4 are not used on the Cisco 7120 series routers. Slot 5 is the service module. Figure 8-5 Port Adapter Slot Numbering—Cisco 7120 Series Slot 5 Slot 3 SLOT 0 SLOT 1 PWR ACT ACT 0 FE 0 / 0 I E3 EN TX FE 0/1 CONS AUX SYS RDY RX RX 2 CEL CAR ALM 7120 - AE3 Slot 1 8-6 LNK LNK 0 1 Slot 0 PA-E3 Serial Port Adapter Installation and Configuration 18498 5 Performing a Basic Configuration Slots in the Cisco 7140 series routers are numbered as shown Figure 8-6. The fixed LAN interface is slot 0, the fixed WAN interfaces are slots 1 and 2, and the modular port adapter interface is slot 4. Slot 3 is not used. Slot 5 is the service module. Figure 8-6 Port Adapter Slot Numbering—Cisco 7140 Series Slot 5 Slot 4 AC OK DC OK OTF RESET SLOT 0 BOOT ERROR PWR EN 5 0 FE 0 / 0 I SLOT 1 ACT ACT EN RX RX 155 - MM TX EN CEL CAR ALM FE 0 / 1 RX LNK LNK 0 1 RX 155 - MM CONS CEL CAR ALM Slot 1 AUX AC OK SYS RDY DC OK OTF TX 2 7140 - 2MM3 18499 SM-EC-DS Slot 0 Slot 2 Performing a Basic Configuration The following steps are for a basic interface configuration for the PA-E3. Press the Return key after each step unless otherwise noted. At any time you can exit the privileged level and return to the user level by entering disable at the prompt: router# disable router> Step 1 At the privileged-level prompt, enter configuration mode and specify that the console terminal is the source of the configuration subcommands: router# configure terminal Enter configuration commands, one per line. router(config)# Step 2 End with CNTL/Z. Specify the interface to configure: • For Cisco 7100 series, Cisco 7200 series, or Cisco uBR7200 series routers, specify the interface to configure by entering the subcommand interface serial followed by the slot/port (port adapter slot number and interface port number). The example that follows is for the interface of the port adapter in slot 3: router(config)# interface serial 3/0 • For a VIP2, specify the interface to configure by entering the subcommand interface serial, followed by the slot/port-adapter/port (interface processor slot number, port adapter slot number, and interface port number). The example that follows is for the interface of the first port adapter on a VIP2 in interface processor slot 1: router(config)# interface serial 1/0/0 • For a Catalyst RSM/VIP2, specify the interface to configure by entering the subcommand interface serial, followed by the port-adapter/port (port adapter slot number and interface port number). The example that follows is for the interface of the first port adapter on a Catalyst RSM/VIP2: router(config)# interface serial 0/0 Configuring the PA-E3 Interfaces 8-7 Configuration Example Step 3 If IP routing is enabled on the system, change to interface configuration mode and use the ip address configuration subcommand to assign an IP address and subnet mask to the interface, as in the following example: router(config-if)# ip address 10.0.0.0 10.255.255.255 Step 4 In interface configuration mode, choose the internal clock source by entering the clock source configuration subcommand, as in the following example: router(config-if)# clock source internal Use the no form of this command to restore the default clock source, which is line. Step 5 In interface configuration mode, change the shutdown state to up and enable the interface as follows: router(config-if)# no shutdown Step 6 Configure additional interfaces as required. Step 7 When you have included all of the configuration subcommands to complete the configuration, press Ctrl-Z to exit configuration mode. Step 8 Write the new configuration to nonvolatile memory as follows: router# copy running-config startup-config [OK] router# To check the interface configuration using show commands, proceed to the “Using show Commands to Display Interface and System Information” section on page 8-12. Configuration Example The following example shows a typical configuration for the PA-E3 on a Cisco 7500 series router: router> enable router# configure terminal router(config)# interface serial router(config)# interface serial 1/0/0 router(config)# ip address 1.1.1.10 255.255.255.0 router(config-if)# clock source internal router(config-if)# no shutdown router(config-if)# ^Z Customizing the PA-E3 You can customize the PA-E3. The features you can customize have default values that will probably suit your environment and need not be changed. However, you might need to enter configuration commands, depending on the requirements for your system configuration and the protocols you plan to route on the interface. Perform the tasks in the following sections if you need to customize the PA-E3. 8-8 PA-E3 Serial Port Adapter Installation and Configuration Setting the Bandwidth Setting the Bandwidth In interface configuration mode, reduce effective bandwidth (range of 22 to 34010 kilobits per second) by entering the dsu bandwidth configuration subcommand, as in the following example: router(config-if)# dsu bandwidth 16000 Use the no form of this command to return to the default, 34010. Note The local port configuration must match the remote port configuration. For example, if you reduce the effective bandwidth to 16000 on the local port, you must do the same on the remote port. Defining the DSU Mode In interface configuration mode, define the DSU interoperability mode by entering the dsu mode [0 | 1] configuration subcommand, as in the following example: router(config-if)# dsu mode 1 Use the no form of this command to return to the default, 0. Note The local port configuration must match the remote port configuration. For example, if you define the DSU interoperability mode as 1 on the local port, you must do the same on the remote port. You need to know what type of DSU is at the remote port to find out if it interoperates with the PA-E3. For E3 serial interfaces, specify mode 0 for connection from a PA-E3 to another PA-E3 or a Digital Link DSU (DL3100). Specify mode 1 for connection from a PA-E3 to a Kentrox DSU. Also refer to the “Interoperability Guidelines for PA-E3 DSUs” section on page 15 for information regarding DSU feature compatibilities. Defining Set Bit (National) In interface configuration mode, define set bit in G751 frame (national bit) by entering the national bit [0 | 1] configuration subcommand, as in the following example: router(config-if)# national bit 1 Use the no form of this command to return to the default, which is 0. Enabling E3 Scrambling In interface configuration mode, enable E3 scrambling by entering the scramble configuration subcommand, as in the following example: router(config-if)# scramble Use the no form of this command to restore the default value, which is disabled. Note The local port configuration must match the remote port configuration. For example, if you enable scrambling on the local port, you must do the same on the remote port. Also refer to the “Interoperability Guidelines for PA-E3 DSUs” section on page 15 for information regarding DSU feature compatibilities. Configuring the PA-E3 Interfaces 8-9 Configuring Cyclic Redundancy Checks Specifying E3 Framing In interface configuration mode, specify E3 framing by entering the framing {g751 | bypass} configuration subcommand, as in the following example: router(config-if)# framing g751 Use the no form of this command to return to the default, which is G.751 framing. Note If you use the bypass option, scrambling must be set to the default, disabled; the DSU mode must be set to the default, 0; and the DSU bandwidth must be set to the default, 34010. Setting the Cable Length In interface configuration mode, set the cable length (0 to 450 feet), as in the following example: router(config-if)# cablelength 250 Use the no form of this command to return to the default, which is 10 feet. Configuring Cyclic Redundancy Checks The PA-E3 uses a 16-bit cyclic redundancy check (CRC) by default; it also supports a 32-bit CRC. The CRC is an error-checking technique that uses a calculated numeric value to detect errors in transmitted data. The sender of a data frame divides the bits in the frame message by a predetermined number to calculate a remainder or frame check sequence (FCS). Before sending the frame, the sender appends the FCS value to the message so that the frame contents are exactly divisible by the predetermined number. The receiver divides the frame contents by the same predetermined number that the sender used to calculate the FCS. If the result is not 0, the receiver assumes that a transmission error occurred and sends a request to the sender to resend the frame. Note To enable a 32-bit CRC on an interface, follow Step 1 and Step 2 of the preceding procedure (enter configuration mode and specify the slot and port address of the PA-E3, and the interface port number for a VIP2), and then enter the command crc 32. Enter Ctrl-Z to exit from configuration mode. For a Cisco 7100 series, Cisco 7200 series, or Cisco uBR7200 series router, use the following example: router# configure terminal Enter configuration commands, one per line. router(config)# router(config)# interface serial 3/0 router(config-int)# crc 32 Ctrl-z 8-10 PA-E3 Serial Port Adapter Installation and Configuration End with CNTL/Z. Checking the Configuration For a VIP2, use the following example: router# configure terminal Enter configuration commands, one per line. router(config)# router(config)# interface serial 1/0/0 router(config-if)# crc 32 Ctrl-z End with CNTL/Z. For a Catalyst RSM/VIP2, use the following example: router# configure terminal Enter configuration commands, one per line. router(config)# router(config)# interface serial 0/0 router(config-if)# crc 32 Ctrl-z End with CNTL/Z. To disable CRC-32 and return to the default CRC-16 setting, specify the slot and port address (and the interface port number for a VIP2) and use the no crc 32 command. For complete command descriptions and instructions, refer to the related software documentation. Note When enabling a 32-bit CRC on an interface, ensure that the remote device is also configured for a 32-bit CRC. Both the sender and the receiver must use the same CRC setting. To check the interface configuration using show commands, proceed to the following section, “Checking the Configuration.” Checking the Configuration After configuring the new interface, use the show commands to display the status of the new interface or all interfaces, the ping command to check connectivity, and the loopback command to verify the physical interface. Using show Commands to Verify Status Use show commands to verify that the new interfaces are configured and operating correctly: Step 1 Use the show version command to display the system hardware configuration. Ensure that the list includes the new interfaces. Step 2 Display all of the current port adapters and their interfaces with the show controllers command. Verify that the new PA-E3 appears in the correct slot. Step 3 Specify one of the new interfaces as follows: • show interfaces type slot/port command on Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers • • show interfaces type slot/port-adapter/port on the VIP2 show interfaces port-adapter/port on the Catalyst RSM/VIP2 Verify that the first line of the display specifies the interface with the correct slot number and that the interface and line protocol are in the correct state: up or down. Configuring the PA-E3 Interfaces 8-11 Checking the Configuration Step 4 Specify one of the new interfaces as follows: • show interfaces port adapter type slot/port on Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers • • show interfaces type slot/port adapter/interface command on the VIP2 show interfaces port adapter/interface command on the Catalyst RSM/VIP2 Verify that the first line of the display specifies the interface with the correct slot number and that the interface and line protocol are in the correct state: up or down. Step 5 View the information that is specific to the serial interface hardware: • For Cisco 7100, Cisco 7200 series and Cisco uBR7200 series routers, specify the new serial interface with the show controllers serial [port adapter slot number/interface port number] command, and verify that the first line of the display specifies the interface with the correct slot number. • For a VIP2, specify information that is specific to the new serial interface with the show controllers serial [type slot/port adapter/interface] command, and verify that the first line of the display specifies the interface with the correct slot number. • For a Catalyst RSM/VIP2, specify information that is specific to the new serial interface with the show controllers serial [port adapter/interface] command, and verify that the first line of the display specifies the interface with the correct slot number. Step 6 Display the protocols configured for the entire system and for the specific interfaces with the show protocols command. If necessary, return to configuration mode to add or remove protocol routing on the system or on specific interfaces. Step 7 Display the running configuration file with the show running-config command. Display the configuration stored in NVRAM using the show startup-config command. Verify that the configuration is accurate for the system and each interface. If the interface is down and you configured it as up, or if the displays indicate that the hardware is not functioning properly, ensure that the network interface is properly connected and terminated. If you still have problems bringing the interface up, ask a service representative for assistance. Using show Commands to Display Interface and System Information For Cisco 7100, Cisco 7200, or Cisco uBR7200 series routers, to display information about a specific interface, use the show interfaces command with the interface type and port address in the format show interfaces type slot/port. 8-12 PA-E3 Serial Port Adapter Installation and Configuration Using show Commands to Display Interface and System Information The following example of the show interfaces type slot/port command shows all of the information specific to the serial E3 port (interface port 0) in port adapter slot 2: router# show interfaces serial 2/0 Serial2/0 is up, line protocol is up Hardware is M1T-E3 pa Internet address is 172.16.0.0/8 MTU 4470 bytes, BW 34010 Kbit, DLY 200 usec, rely 255/255, load 1/255 Encapsulation HDLC, loopback not set, keepalive not set Last input 00:00:05, output 00:00:46, output hang never Last clearing of "show interface" counters never Queueing strategy: fifo Output queue 0/40, 0 drops; input queue 0/75, 0 drops 5 minute input rate 0 bits/sec, 0 packets/sec 5 minute output rate 0 bits/sec, 0 packets/sec 22 packets input, 7128 bytes, 0 no buffer Received 22 broadcasts, 0 runts, 0 giants 0 parity 6 input errors, 3 CRC, 0 frame, 0 overrun, 0 ignored, 3 abort 22 packets output, 7348 bytes, 0 underruns 0 output errors, 0 applique, 6 interface resets 0 output buffer failures, 0 output buffers swapped out 1 carrier transitions rxLOS inactive rxLOF inactive rxAIS inactive txAIS inactive txRAI inactive For a VIP2, the show interfaces type slot/port-adapter/port command displays status information (including the physical slot and port address) for the interfaces you specify. In this example, a one-port E3 serial port adapter-configured VIP2 is in chassis slot 1, in port adapter slot 0. router# show interfaces serial 1/0/0 Serial1/0/0 is up, line protocol is up Hardware is cyBus Serial Internet address is 10.0.0.0/24 MTU 4470 bytes, BW 45045 Kbit, DLY 200 usec, rely 255/255, load 1/255 Encapsulation HDLC, loopback not set, keepalive not set Last input 2d22h, output 00:00:19, output hang never Last clearing of “show interface” counters 2d20h Queueing strategy: fifo Output queue 0/40, 0 drops; input queue 0/75, 0 drops 5 minute input rate 0 bits/sec, 0 packets/sec 5 minute output rate 0 bits/sec, 0 packets/sec 0 packets input, 0 bytes, 0 no buffer Received 0 broadcasts, 0 runts, 0 giants, 0 parity 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort 4084 packets output, 1298712 bytes, 0 underruns 0 output errors, 0 applique, 0 interface resets 0 output buffer failures, 0 output buffers swapped out 0 carrier transitions For a Catalyst RSM/VIP2, the show interfaces port-adapter/port command displays status information for the interfaces you specify. In this example, a one-port E3 serial port adapter-configured Catalyst RSM/VIP2 in port adapter slot 0. router# show interfaces serial 0/0 Serial0/0 is up, line protocol is up Hardware is cyBus Serial Internet address is 10.0.0.0/24 MTU 4470 bytes, BW 45045 Kbit, DLY 200 usec, rely 255/255, load 1/255 Encapsulation HDLC, loopback not set, keepalive not set Last input 2d22h, output 00:00:19, output hang never Last clearing of “show interface” counters 2d20h Queueing strategy: fifo Configuring the PA-E3 Interfaces 8-13 Checking the Configuration Output queue 0/40, 0 drops; input queue 0/75, 0 drops 5 minute input rate 0 bits/sec, 0 packets/sec 5 minute output rate 0 bits/sec, 0 packets/sec 0 packets input, 0 bytes, 0 no buffer Received 0 broadcasts, 0 runts, 0 giants, 0 parity 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort 4084 packets output, 1298712 bytes, 0 underruns 0 output errors, 0 applique, 0 interface resets 0 output buffer failures, 0 output buffers swapped out 0 carrier transitions For Cisco 7100, Cisco 7200, and Cisco uBR7200 series routers, use the show controllers serial command, using arguments such as the slot and port number (slot/port), to display information that is specific to the serial interface hardware. Following is an example of the show controllers serial slot/port command that shows the serial port adapter installed on a Cisco 7200 series router in chassis slot 3: router# show controllers serial 3/0 M1T-Serial: show controller: PAS unit 0, subunit 0, f/w version 1-23, rev ID 0x1, version 2 idb = 0x608E3340, ds = 0x608E50C0, ssb=0x608E5A84 Clock mux=0x35, ucmd_ctrl=0x8, port_status=0x25 maxdgram=4474, bufpool=64Kb, 128 particles TM=down CA=up LC=down line state: up Serial DTE cable (Display text omitted.) For a VIP2, use the show controllers serial command, using arguments such as those that specify the slot, port adapter, and port numbers (slot/port-adapter/port), to display information that is specific to the serial interface hardware. Following is an example of the show controllers serial slot/port adapter/interface command that shows serial port 2/0/1 on a one-port PA-E3 installed on a VIP2 in chassis slot 1: router# show controllers serial 2/0/1 Serial2/0/1 Mx E3(2) HW Revision 0x2, FW Revision 2.42 Framing is g751, Clock Source is Line, Bandwidth limit is 34010. National Bit is 0, International Bits are: 0 0 DSU mode 0 Data in current interval (421 seconds elapsed): 0 Line Code Violations, 0 P-bit Coding Violation 0 C-bit Coding Violation 0 P-bit Err Secs, 0 P-bit Severely Err Secs 0 Severely Err Framing Secs, 0 Unavailable Secs 0 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Severely Errored Secs Total Data (last 1 15 minute intervals): 4 Line Code Violations, 0 P-bit Coding Violation, 0 C-bit Coding Violation, 0 P-bit Err Secs, 0 P-bit Severely Err Secs, 0 Severely Err Framing Secs, 0 Unavailable Secs, 3 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Severely Errored Secs No alarms detected. (Display text omitted.) 8-14 PA-E3 Serial Port Adapter Installation and Configuration Using show Commands to Display Interface and System Information For a Catalyst RSM/VIP2, use the show controllers serial command, using arguments such as those that specify the port adapter and port numbers (port-adapter/port), to display information that is specific to the serial interface hardware. Following is an example of the show controllers serial port-adapter/interface command that shows serial port 0/1 on a one-port PA-E3 installed on a Catalyst RSM/VIP2: router# show controllers serial 0/1 Serial0/1 Mx E3(2) HW Revision 0x2, FW Revision 2.42 Framing is g751, Clock Source is Line, Bandwidth limit is 34010. National Bit is 0, International Bits are: 0 0 DSU mode 0 Data in current interval (421 seconds elapsed): 0 Line Code Violations, 0 P-bit Coding Violation 0 C-bit Coding Violation 0 P-bit Err Secs, 0 P-bit Severely Err Secs 0 Severely Err Framing Secs, 0 Unavailable Secs 0 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Severely Errored Secs Total Data (last 1 15 minute intervals): 4 Line Code Violations, 0 P-bit Coding Violation, 0 C-bit Coding Violation, 0 P-bit Err Secs, 0 P-bit Severely Err Secs, 0 Severely Err Framing Secs, 0 Unavailable Secs, 3 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Severely Errored Secs No alarms detected. (Display text omitted.) The show version (or show hardware) command displays the configuration of the system hardware (the number of each port adapter type installed), the software version, the names and sources of configuration files, and the boot images. Following is an example of the output from the show version command on a Cisco 7200 series router: router# show version Cisco Internetwork Operating System Software IOS (tm) 7200 Software (C7200-P-M), Version 11.1(16)CA Synced to mainline version: 11.1(10.5) Copyright (c) 1986-1997 by cisco Systems, Inc. Compiled Thu 22-May-97 14:40 Image text-base: 0x600088F0, data-base: 0x604B6000 ROM: System Bootstrap, Version 11.1(5) [mkamson 5], RELEASE SOFTWARE (fc1) ROM: 7200 Software (C7200-BOOT-M), Version 11.1(6), RELEASE SOFTWARE (fc1) byron uptime is 22 minutes System restarted by reload System image file is "paking/poet/c7200-p-mz", booted via tftp from 172.16.0.0 cisco 7206 (NPE150) processor with 12288K/4096K bytes of memory. R4700 processor, Implementation 33, Revision 1.0 (512KB Level 2 Cache) Last reset from power-on X.25 software, Version 2.0, NET2, BFE and GOSIP compliant. 4 Ethernet/IEEE 802.3 interfaces. 1 Serial network interface. 1 FDDI network interface. 125K bytes of non-volatile configuration memory. 1024K bytes of packet SRAM memory. 4096K bytes of Flash internal SIMM (Sector size 256K). Configuration register is 0x2 Configuring the PA-E3 Interfaces 8-15 Checking the Configuration Following is an example of the show version command used with a Cisco 7500 series system: router# show version Cisco Internetwork Operating System Software IOS (tm) GS Software, Version 11.1(16)CA Synced to mainline version: 11.1(10.5) Copyright (c) 1986-1997 by cisco Systems, Inc. Compiled Thu 22-May-97 14:32 Image text-base: 0x600108E0, data-base: 0x60A00000 ROM: System Bootstrap, Version 5.3.2(3.2) [kmac 3.2], MAINTENANCE INTERIM SOFTWARE ROM: GS Software, Version 11.1(8)CA, EARLY DEPLOYMENT RELEASE SOFTWARE (fc1) keats uptime is 22 minutes System restarted by reload System image file booted via tftp from 172.16.0.0 Last reset from power-on G.703/E1 software, Version 1.0. G.703/JT2 software, Version 1.0. SuperLAT software (copyright 1990 by Meridian Technology Corp). Bridging software. X.25 software, Version 2.0, NET2, BFE and GOSIP compliant. TN3270 Emulation software (copyright 1994 by TGV Inc). Chassis Interface. 3 VIP2 controllers (1 FastEthernet)(4 Ethernet)(1 Fddi)(2 E3). 4 Ethernet/IEEE 802.3 interfaces. 1 FastEthernet/IEEE 802.3 interface. 2 Serial network interfaces. 1 FDDI network interface. 125K bytes of non-volatile configuration memory. 8192K bytes of Flash internal SIMM (Sector size 256K). Configuration register is 0x2 To determine which type of port adapter is installed in your system, use the show diag slot command. Specific port adapter information is displayed, as shown in the following example of a one-port PA-E3 in chassis slot 3 on a Cisco 7200 series router: router# show diag 3 Slot 3: E3 PA port adapter, 1 ports Port adapter is analyzed Port adapter insertion time 01:04:31 ago Hardware revision 1.0 Board revision Serial number 3710903 Part number Test history 0x0 RMA number EEPROM format version 1 EEPROM contents (hex): 0x20: 01 71 01 00 00 38 9F B7 49 07 09 03 00 0x30: 06 00 00 00 FF FF FF 00 FF FF FF FF FF 8-16 PA-E3 Serial Port Adapter Installation and Configuration UNKNOWN 73-1801-03 00-00-00 00 00 00 FF FF FF Using show Commands to Display Interface and System Information To determine which type of port adapter is installed on a VIP2 in your system, use the show diag slot command. Specific port adapter information is displayed, as shown in the following example of a one-port PA-E3 in chassis slot 2: router# show diag 2 Slot 2: Physical slot 2, ~physical slot 0xD, logical slot 2, CBus 0 Microcode Status 0x4 Master Enable, LED, WCS Loaded Board is analyzed Pending I/O Status: None EEPROM format version 1 VIP2 controller, HW rev 2.4, board revision D0 Serial number: 04371939 Part number: 73-1684-03 Test history: 0x00 RMA number: 00-00-00 Flags: cisco 7500 EEPROM contents (hex): 0x20: 01 15 02 04 00 42 B5 E3 49 06 94 03 00 00 00 00 0x30: 68 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Slot database information: Flags: 0x4 Insertion time: 0x14A4 (00:23:00 ago) Controller Memory Size: 32 MBytes DRAM, 2048 KBytes SRAM PA Bay 0 Information: E3 Serial PA, 1 port EEPROM format version 1 HW rev 1.00, Board revision AO Serial number: 3549502 Part number: 73-2620-02 To determine which type of port adapter is installed on a Catalyst RSM/VIP2 in your system, use the show diag command. Specific port adapter information is displayed, as shown in the following example of a one-port PA-E3: router# show diag 1 Slot 1: Physical slot 1, ~physical slot 0xD, logical slot 1, CBus 0 Microcode Status 0x4 Master Enable, LED, WCS Loaded Board is analyzed Pending I/O Status: None EEPROM format version 1 VIP2 controller, HW rev 2.4, board revision D0 Serial number: 04371939 Part number: 73-1684-03 Test history: 0x00 RMA number: 00-00-00 Flags: cisco 7500 EEPROM contents (hex): 0x20: 01 15 02 04 00 42 B5 E3 49 06 94 03 00 00 00 00 0x30: 68 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Slot database information: Flags: 0x4 Insertion time: 0x14A4 (00:23:00 ago) Note The slot values displayed by some commands (such as show diag and show controllers cbus) are not relevant to any physical connection; disregard these slot values for the Catalyst RSM/VIP2. Configuring the PA-E3 Interfaces 8-17 Checking the Configuration For a VIP2, use the show controllers cbus command to display all of the current interface processors and their interfaces. Following is an example of the show controllers cbus command that shows serial port 1/0/0 on a one-port PA-E3 installed on a VIP2 in chassis slot 1: router# show controllers cbus MEMD at 40000000, 2097152 bytes (unused 4288, recarves 1, lost 0) RawQ 48000100, ReturnQ 48000108, EventQ 48000110 BufhdrQ 48000138 (2810 items), LovltrQ 48000150 (20 items, 2016 bytes) IpcbufQ 48000160 (32 items, 4096 bytes) IpcbufQ_classic 48000158 (8 items, 4096 bytes) 3570 buffer headers (48002000 - 4800FF10) pool0: 9 buffers, 256 bytes, queue 48000140 pool1: 458 buffers, 1536 bytes, queue 48000148 pool2: 229 buffers, 4512 bytes, queue 48000168 pool3: 4 buffers, 4544 bytes, queue 48000170 slot0: VIP2, hw 2.4, sw 21.40, ccb 5800FF20, cmdq 48000080, vps 8192 software loaded from system IOS (tm) VIP Software (SVIP-DW-M), Version 11.1(16)CA ROM Monitor version 17.0 Ethernet0/0/0, addr 00e0.f7d7.cb00 (bia 00e0.f7d7.cb00) gfreeq 48000148, lfreeq 48000178 (1536 bytes), throttled 0 rxlo 4, rxhi 273, rxcurr 2, maxrxcurr 4 txq 48001A00, txacc 48001A02 (value 152), txlimit 152 Ethernet0/0/1, addr 00e0.f7d7.cb01 (bia 00e0.f7d7.cb01) gfreeq 48000148, lfreeq 48000180 (1536 bytes), throttled 0 rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0 txq 48001A08, txacc 48001A0A (value 0), txlimit 152 Ethernet0/0/2, addr 00e0.f7d7.cb02 (bia 00e0.f7d7.cb02) gfreeq 48000148, lfreeq 48000188 (1536 bytes), throttled 0 rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0 txq 48001A10, txacc 48001A12 (value 0), txlimit 152 Ethernet0/0/3, addr 00e0.f7d7.cb03 (bia 00e0.f7d7.cb03) gfreeq 48000148, lfreeq 48000190 (1536 bytes), throttled 0 rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0 txq 48001A18, txacc 48001A1A (value 0), txlimit 152 (Display text omitted.) 8-18 PA-E3 Serial Port Adapter Installation and Configuration Using the ping Command to Verify Network Connection For a Catalyst RSM/VIP2, use the show controllers cbus command to display all of the current interfaces. Following is an example of the show controllers cbus command that shows serial port 0/0 on a one-port PA-E3 installed on a Catalyst RSM/VIP2: router# show controllers cbus MEMD at 40000000, 2097152 bytes (unused 4288, recarves 1, lost 0) RawQ 48000100, ReturnQ 48000108, EventQ 48000110 BufhdrQ 48000138 (2810 items), LovltrQ 48000150 (20 items, 2016 bytes) IpcbufQ 48000160 (32 items, 4096 bytes) IpcbufQ_classic 48000158 (8 items, 4096 bytes) 3570 buffer headers (48002000 - 4800FF10) pool0: 9 buffers, 256 bytes, queue 48000140 pool1: 458 buffers, 1536 bytes, queue 48000148 pool2: 229 buffers, 4512 bytes, queue 48000168 pool3: 4 buffers, 4544 bytes, queue 48000170 slot0: VIP2, hw 2.4, sw 21.40, ccb 5800FF20, cmdq 48000080, vps 8192 software loaded from system IOS (tm) VIP Software (SVIP-DW-M), Version 11.1(16)CA ROM Monitor version 17.0 Ethernet0/0, addr 00e0.f7d7.cb00 (bia 00e0.f7d7.cb00) gfreeq 48000148, lfreeq 48000178 (1536 bytes), throttled 0 rxlo 4, rxhi 273, rxcurr 2, maxrxcurr 4 txq 48001A00, txacc 48001A02 (value 152), txlimit 152 Ethernet0/1, addr 00e0.f7d7.cb01 (bia 00e0.f7d7.cb01) gfreeq 48000148, lfreeq 48000180 (1536 bytes), throttled 0 rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0 txq 48001A08, txacc 48001A0A (value 0), txlimit 152 Ethernet0/2, addr 00e0.f7d7.cb02 (bia 00e0.f7d7.cb02) gfreeq 48000148, lfreeq 48000188 (1536 bytes), throttled 0 rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0 txq 48001A10, txacc 48001A12 (value 0), txlimit 152 Ethernet0/3, addr 00e0.f7d7.cb03 (bia 00e0.f7d7.cb03) gfreeq 48000148, lfreeq 48000190 (1536 bytes), throttled 0 rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0 txq 48001A18, txacc 48001A1A (value 0), txlimit 152 (Display text omitted.) Note The slot values displayed by some commands (such as show diag and show controllers cbus) are not relevant to any physical connection; please disregard these slot values for the Catalyst RSM/VIP2. For complete command descriptions and examples for the Cisco 7100 series routers, Cisco 7200 series routers, Cisco uBR7200 series routers, the VIP2, and the Catalyst RSM/VIP2, refer to the publications listed in the “Related Documentation” section on page vi. Using the ping Command to Verify Network Connection The ping command allows you to verify that an interface port is functioning properly and to check the path between a specific port and connected devices at various locations on the network. For example, after you verify that the system and VIP2 have booted successfully and are operational, you can use the ping command to verify the status of interface ports. Refer to the publications listed in the “Related Documentation” section on page vi for detailed command descriptions and examples. The ping command sends an echo request out to a remote device at an IP address that you specify. After sending a series of signals, the command waits a specified time for the remote device to echo the signals. Each returned signal is displayed as an exclamation point (!) on the console terminal; Configuring the PA-E3 Interfaces 8-19 Checking the Configuration each signal that is not returned before the specified timeout is displayed as a period (.). A series of exclamation points (!!!!!) indicates a good connection; a series of periods (.....) or the message [timed out] or [failed] indicates that the connection failed. Following is an example of a successful ping command to a remote server with the address 10.0.0.0: router# ping 10.0.0.0Type escape sequence to abort. Sending 5, 100-byte ICMP Echoes to 1.1.1.10, timeout is 2 seconds: !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 1/15/64 ms router# If the connection fails, verify that you have the correct IP address for the server and that the server is active (powered on), and repeat the ping command. Refer to the publications listed in the “Related Documentation” section on page vi for complete descriptions of interface subcommands and the configuration options available for VIP2-related interfaces, and to determine which subcommands and configuration options support VIP2 functionality. Using the loopback Command to Verify the Physical Interface Use the loopback {dte | local | network {line | payload} command to troubleshoot the E3 serial port adapter at the physical interface level. The command loops all packets from the E3 interface either back to the interface or from the network back out toward the network. Use the no form of the command to remove the loop. The following examples of the loopback {dte | local | network {line | payload} command configure loopback modes on the single interface (interface 0) of a one-port E3 serial port adapter in port adapter slot 0 of a VIP2 in chassis slot 10 of a Cisco 7500 series router: • Set the interface into loopback data terminal equipment (DTE) mode as follows: Router# configure terminal Enter configuration commands, one per line. End with CNTL/Z. router(config)# interface serial 10/0/0 router(config-if)# loopback dte Loopback DTE loops the router output data back toward the router (after the line interface unit). • Set the interface into local loopback mode as follows: Router# configure terminal Enter configuration commands, one per line. End with CNTL/Z. router(config)# interface serial 10/0/0 router(config-if)# loopback local Local loopback loops the router output data back toward the router at the framer. • Set the interface into network line loopback mode as follows: Router# configure terminal Enter configuration commands, one per line. End with CNTL/Z. router(config)# interface serial 10/0/0 router(config-if)# loopback network line Network line loopback loops the data back toward the network (before the framer). 8-20 PA-E3 Serial Port Adapter Installation and Configuration Using the loopback Command to Verify the Physical Interface • Set the interface into network payload loopback mode as follows: Router# configure terminal Enter configuration commands, one per line. End with CNTL/Z. router(config)# interface serial 10/0/0 router(config-if)# loopback network payload Network payload loopback loops just the payload data back toward the network at the E3 framer. Configuring the PA-E3 Interfaces 8-21 Checking the Configuration 8-22 PA-E3 Serial Port Adapter Installation and Configuration
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 1999:06:29 17:49:39 Producer : Acrobat Distiller Command 3.01 for Solaris 2.3 and later (SPARC) Creator : Frame 5.5 Modify Date : 1999:07:12 14:40:03 Page Count : 68EXIF Metadata provided by EXIF.tools