Climax Technology Co 1041RV Medical Emergency Alarm System User Manual CTC 1041RV

Climax Technology Co Ltd Medical Emergency Alarm System CTC 1041RV

Users Manual

c  August 12, 2013
                                                                                                                                 Table of Contents  1. Application Overview________________________________________________________ 1 1.1. Identifying The Parts ____________________________________________________________ 1 1.2. The Power Supply  ______________________________________________________________ 2 1.3. Line Capture ____________________________________________________________________ 3 1.4. How to install the Control Panel __________________________________________________ 3 2. Learn-in the Devices  ________________________________________________________ 4 2.1. Learning Pendant #1 ____________________________________________________________ 4 2.2. Learning Pendant #2 ____________________________________________________________ 4 2.3. Learning in DECT Devices (CTC-808RV, CP-23 and WTRVS) ________________________ 5 2.4. Removing Pendant #1 & #2 ______________________________________________________ 6 3. System Configuration _______________________________________________________ 7 3.1. Entering Programming Mode  ____________________________________________________ 7 3.1.1. Local Programming Mode (Optional) __________________________________________________  7 3.1.2. Remote Programming Mode __________________________________________________________  7 3.1.3. CTC-835 Programmer ________________________________________________________________  8 3.2. Programming Your 1041RV ______________________________________________________ 8 4. Operation  _________________________________________________________________ 20 4.1. Idle Mode ______________________________________________________________________ 20 4.1.1. Auto-Answer Incoming Phone Calls __________________________________________________  20 4.1.2. Non-Emergency Speech Call  ________________________________________________________  21 4.1.3. AC Power Check Up ________________________________________________________________  21 4.1.4. CTC-1041RV Low Battery  ___________________________________________________________  21 4.1.5. CTC-1041RV  Battery Disconnection _________________________________________________  21 4.1.6. Devices Low Battery ________________________________________________________________  22 4.1.7. Automatic Check-in Report = Periodic Test Call _______________________________________  22 4.1.8. Mobility Timer ______________________________________________________________________  22 4.1.9. No Pendant Present  ________________________________________________________________  23 4.2. Alarm Activation _______________________________________________________________ 23 4.3. Walk Test (Range Test) _________________________________________________________ 27 4.4. Global Test ____________________________________________________________________ 28 4.5. Factory Reset __________________________________________________________________ 28
                                                                                                                                 5. Appendix __________________________________________________________________  29 5.1. CID Event code ________________________________________________________________ 29 5.2. Tunstall Event code ____________________________________________________________ 30 5.3. Scancom Event code ___________________________________________________________ 30 5.4. CTC-1041RV Programming Command Table _____________________________________ 32
                                                                                                                                     1 1. Application Overview  1.1. Identifying The Parts TOP VIEW           1.      GREEN LED —  ON: AC Power is ON. —  FLASH  every  second:  AC  Power failure —  FLASH  every  2  seconds:  Panel  or Device Low battery —  SLOW FLASH: Line Fault (on and off at every second) —  QUICK  FLASH  every  2  seconds: Supervision failure 2.      RED LED —  ON: Off-hook / Waiting retry pause / Ready  to  enter  Programming  Mode (before entering PIN code) — FLASH:  Programming  Mode  / Pendant Learning Mode 3.      GREEN RESET BUTTON —  Press once  in  normal mode to  reset mobility timer (see command 44) —  Before  CTC-1041RV  dials  out  for alarm reporting, press once to cancel the alarm reporting —  During or at-the-end of conversation, press  once  to  terminate  two-way voice communication —  In Programming Mode, press once to return to Idle Mode —  Press & hold for 3 sec: dial the Non-Emergency call. (See section 4.1.2.)   —  Press  &  hold  for  6  sec:  enter Learning Mode  — Press  &  hold  for  16  sec:  disable  mobility setting   4.     RED HELP BUTTON (with backlight) —  Back-lit  disigned  for  easy  access  at night —  Backlight  illuminates  when  reporting and off-hook —  Backlight  flashes  during  the  waiting period until help arrives 5.     Microphone  6.     Speaker   REAR VIEW     7.     Phone Jack marked           —  Telephone unit connection 8.     Line Jack marked  —  Phone line connection from wall 9.     DC Jack — DC 12V 1A power adapter connection 10.    Battery Switch 11.    Local Programming Telephone Unit Input — A special telephone cord to connect CTC-1041RV and your phone unit for Local Programming (optional).
                                                                                                                                     2BACK VIEW   12.     Mounting Holes 13.     Mounting Bracket                  1.2. The Power Supply    An  AC  power  adapter  is  required  to connect  to  a  wall  outlet.  Be  sure  only  to use  an  adapter  with  the  appropriate  AC voltage  rating  to  prevent  component damage. A DC 12V output and 1A adapter is generally used to power CTC-1041RV.    In  addition  to  the  adapter,  there  is  a rechargeable battery inside CTC-1041RV, which  serves  as  a  back-up  in  case  of  a power failure.   During  normal  operation,  the  AC  power adapter  is used  to  supply  power  to  CTC-1041RV  and  at  the  same  time  recharge the battery.   It  takes  approximately  72  hours  to  fully charge the battery.  The battery can be manually disconnected by the battery switch located at the back.   Battery  Switch  is  set  as  OFF  by  factory default,  the  battery  will  not  be  charged when  AC  power  is  connected,  nor  will  it serve  as  a  back-up  power  source  when AC power  is  missing. You need to  switch the  battery  to  ON  after  supplying  AC power to CTC-1041RV  <<NNOOTTEE>>   Please make sure the battery switch is slid  back  to  ON  position  (as  marked) after  manually  disconnected  the rechargable battery.
                                                                                                                                     31.3. Line Capture   CTC-1041RV  features  Master  Control over the telephone line. That means, even if  the  phone  line  is  engaged,  the  CTC-1041RV has  the  power to  circumvent the line and dial-out anyway.  <<NNOOTTEE>>   The  Line  Capture  feature  is  only available when household phones are connected  after  the  CTC-1041RV  wiring. For Example:            CTC-1041RV  has  the  Line  Capture  function over TEL #2 and TEL #3, but not TEL #1.              1.4. How to install the Control Panel Locating  a  suitable  position  for  the Control Panel   The  Control  Panel  requires  main  power and a constant telephone connection.   The  Control  Panel  should  be  easily accessible.   The Control Panel should not be placed in a damp location, such as a bathroom.   The  Control  Panel  should  not  be  placed close  to  any  heat  source,  such  as microwave  ovens,  which  can  reduce signal strength.   The  Control  Panel  should  not  be  located alongside other radio transmitting devices, such  as  mobile  phones,  cordless  phone, or  wireless  computer  network  (Wi-Fi) devices.   Important: When drilling into a wall, ensure there are no hidden cables or pipes.  Mounting the Control Panel The Control Panel can be mounted on the wall or wherever desired (e.g. on the table).  Ensure the  Control  Panel  is  fitted  at  approximately chest  height  where  the  buttons,  microphone, and  speaker  can  be  easily  accessed  and operated.   Use  the  2  holes  of  the  Wall  Mounting Bracket as a template, mark off the holes’ positions.   Drill  2  holes  and  insert  the  wall  plugs  if fixing into plaster or brick.   Screw the base to the wall.   Hook  the  Control  unit  onto  the  Wall Mounting  Bracket  (holding  the  unit  with the front facing you).    Telecom CTC-1041RV TEL 1 TEL 3 TEL 2
                                                                                                                                     42. Learn-in the Devices There  are  two  methods  to  learn  in  devices: local learning and command learning. Total  10  sensors  are  allowed  to  be  learnt  into  the system.  The  combined  numbers  of  DECT devices  (WTRVS,  CP-23  and  CTC-808RV) learned into CTC-1041RV can be up to 4.  Local Learning:  You  can  use  the  local  learning  method  to learn  in  2  RF  devices  or  4  DECT  devices. Refer to 2.1. Learning Pendant #1 to learn in the first RF device, 2.2. Learning Pendant #2 to  learn  in  the  second  RF  device  and  2.3. Learning in DECT Devices to learn in up to 4 DECT devices.  1. The  user  can  turn  CTC-1041RV  into learning mode to learn in WTR- Series, Fall Sensor, WTRVS, CP-23 and CTC-808RV.  2. If you have learned the first device to the system  by following  instructions  in  the  2.1 section,  you  are  not  allowed  to  use Command  91  (Command  Learning)  to learn in another device.  3. If  you  have  learned  the  second  device to the sytem  as  instructed in the  2.2  section, you  are  not  allowed to  use  Command  92 (Command  Learning)  to  learn  in  another device.   Command Learning:  1.  The  user  can  use  Commands  91-94  to learn  devices  into  the  system.  These devices  include  PIR  Sensor,  Smoke Detector,  Panic  Button,  Carbon Monoxide  Detector,  Wrist  &  Neck Transmitter,  Water  Sensor,  Pendant Transmitter,  WTR-  series,  Fall  Sensor, WTRVS,  CP-23  and  CTC-808RV. Please refer to 3.2 Programming Your 1041RV: Commands 91-94 for details.  2.  Command  91  is  designed  to  learn  in WTR- Series, Fall Sensor, WTRVS, CP-23  or CTC-808RV only.  3.  Command  92  is  designed  to  learn  in WTR- Series, Fall Sensor, WTRVS, CP-23 or CTC-808RV only.  4.  Command  93  is  designed  to  learn  in WTR-  Series  or  Fall  Sensor  for  silent reporting. Command  93  can also learn in WTRVS,  CP-23  or  CTC-808RV,  but WTRVS, CP-23 or CTC-808RV learned in  via  Command  93  does  not  provide silent  reporting  (they  provide  two-way communication). 5.  Command  94  is  designed  to  learn  in the following sensors:   PIR Sensor  ----- PIR  Smoke Detector ---- SD  Carbon Monoxide Detector---- CO  Fixed Panic Button ---- PB  Wrist Transmitter ---- WTR  Pendant Transmitter ---- WTR  Water Sensor ---- WS   Fall Sensor ---- FS  Talking Pendant ---- WTRVS   Call Point ---- CP-23  Voice Satellite ---- CTC-808RV    2.1. Learning Pendant #1 Please see the following instructions to learn in WTR- Series and Fall Sensor.   For Normal Wrist Transmitters (WTR-) or Fall Sensor 1.  Press  and  hold  the  RESET  button    of CTC1041RV for 6 seconds until you hear the  double  beep    and followed  by  a  long beep.  2.  The  RED  LED  starts  flashing.  CTC-1041RV is now in the learning mode.  3.  Press and both the RESET and Pendant #1 (WTR- Series or Fall Sensor) buttons simultaneously  until  CTC-1041RV  emit  a double-beep.  4.  Pendant  #1  has  been  learnt-in successfully.   5.  Press  the  Reset  &  Help  button  at  the same time to exit the learning mode. The RED  LED  will  dim  to  indicate  that  the system is back to idle mode.   2.2. Learning Pendant #2 Please see the following instructions to learn in the  second  device  (WTR-  Series  and  Fall Sensor).
                                                                                                                                     5For Normal Wrist Transmitters (WTR-) or Fall Sensor 1.  Press  and  hold  the  RESET  button    of CTC1041RV for 6 seconds until you hear the  double  beep    and followed  by  a  long beep.  2.  The  RED  LED  starts  flashing.  CTC-1041RV is now in the learning mode.  3.  Press  and  both  the  HELP  and  Pendant #1 (WTR- Series or Fall Sensor) buttons simultaneously until CTC-1041RV emits a double-beep.  4.  Pendant  #2  has  been  learnt-in successfully.   5.  Press  the  Reset  &  Help  button  at  the same time to exit the learning mode. The RED  LED  will  dim  to  indicate  that  the system is back to idle mode.   2.3. Learning in DECT Devices (CTC-808RV, CP-23 and WTRVS) CTC-1041RV can learn in 4 DECT devices at  most.  The  DECT  devices  will  be automatically assigned to Zone 1~Zone 10 except Zone 3.   Learning in CTC-808RV 1.  Press  and  hold  the  green  reset button  of CTC-1041RV for 6 seconds until you hear two beeps followed by a long beep.  2.  The red LED starts flashing. CTC-1041RV is now in learning mode. <<NNOOTTEE>>   CTC-1041RV  can  learn  in  4  DECT devices  at  most.  If  fewer  than  4  DECT devices  have  been  learned  into  CTC-1041RV,  the  red  LED  will  flash  slowly  to indicate  there  are  still  empty  zones  for DECT  devices.  If  CTC-1041RV  has learned 4 DECT devices and there are no more  zones  for  DECT  devices,  the  red LED will flash quickly.   You  can  clear  Zone  1  and  Zone  2  for DECT  devices  to  be  learned  in  by pressing  and  holding  CTC-1041RV’s green reset button for 6 seconds until you hear  a  long  beep  that  indicates  the devices in Zone 1 and Zone 2 have been simultaneously  removed.  Now  you  can learn DECT devices into Zone 1 and Zone 2.   The  above  method,  however,  cannot create  available  zones  for  more  DECT devices  if  CTC-1041RV  has  already learned  in  4  DECT  devices  and  none  of them are in Zone 1 or Zone 2. 3.  Press  and  hold  CTC-808RV’s  learning button  for  5  seconds  until  you  hear  2 beeps.  Release  the  button  and  CTC-808RV will emit one short beep to indicate it is now in learning mode. The green LED of CTC-808RV is turned on. 4.  When CTC-808RV is successfully learned in, both CTC-1041RV and CTC-808RV will emit  two  beeps  to  indicate  the  successful learning.  The  green  LED  on  CTC-808RV will be turned off. <<NNOOTTEE>>   If  you  do  not  hear  the  two  beeps  and  if CTC-808RV emits one short beep and its green LED is off and red LED steady on, that  means  the  learning  process  has failed.  Please  repeat  the  learning  steps again. 5.  Check if CTC-808RV has been learned in  successfully.  Press  the  HELP  button  on CTC-808RV  and  you  will  hear  continuous beeps  from  CTC-808RV.  When  CTC-808RV  beeps,  the  CTC-1041RV  will respond  with  1  beep  to  indicate that  CTC-808RV is within the operation range.   6.  Press  the  reset  and  help  buttons  at  the same time to  exit  learning  mode. The  red LED will dim to indicate that CTC-1041RV is back to idle mode.   Learning in CP-23 or WTRVS 1.  Press  and  hold  the  green  reset button  of CTC-1041RV for  6  seconds  until  you  hear two beeps followed by a long beep.  2.  The red LED starts flashing. CTC-1041RV is now in learning mode. <<NNOOTTEE>>    CTC-1041RV  can  learn  in  4  DECT devices  at  most.  If  fewer  than  4  DECT devices  have  been  learned  into  CTC-1041RV,  the  red  LED  will  flash  slowly  to
                                                                                                                                     6indicate  there  are  still  empty  zones  for DECT  devices.  If  CTC-1041RV  has learned 4 DECT devices and there are no more  zones  for  DECT  devices,  the  red LED will flash quickly.   You  can  clear  Zone  1  and  Zone  2  for DECT  devices  to  be  learned  in  by pressing  and  holding  CTC-1041RV’s green reset button for 6 seconds until you hear  a  long  beep  that  indicates  the devices in Zone 1 and Zone 2 have been simultaneously  removed.  Now  you  can learn DECT devices into Zone 1 and Zone 2.   The  above  method,  however,  cannot create  available  zones  for  more  DECT devices  if  CTC-1041RV  has  already learned  in  4  DECT  devices  and  none  of them are in Zone 1 or Zone 2. 3.  Press and hold the CP-23/WTRVS button for  8 seconds until you hear  a long beep. The  red  LED  of  CP-23/WTRVS  is  turned on.  CP-23/WTRVS  is  now  in  learning mode. 4.  Now the LED of CP-23/WTRVS turns from red  to  green.  The  green  LED  blinks.  The Control  Panel  will  emit  two  quick  beeps. Afterwards  CP-23/WTRVS  will  emit  one beep and its green  LED will be turned  on and  then  go  off  instantly.  CP-23/WTRVS has been successfully learned in.  <<NNOOTTEE>>   You cannot learn in the same CP-23/WTRVS twice. 5.  Check if CP-23/WTRVS has been learned in  successfully.  Press  the  CP-23/WTRVS button and you will hear continuous beeps from  CP-23/WTRVS.  When  CP-23/WTRVS  beeps,  the  CTC-1041RV  will respond  with  1  beep  to  indicate  that  CP-23/WTRVS is within the operation range. 6.  Press  the  reset  and  help  buttons  at  the same time to  exit  learning  mode. The  red LED will dim to indicate that CTC-1041RV is back to idle mode.   2.4. Removing Pendant #1 & #2 CTC-1041RV  can  be  programmed  to  remove Pendant #1 & #2 by Commands 80, 81 or 82. Please  refer  to  3.2  Programming  Your 1041RV: Commands 80,  81 or 82 for details. To  remove  WTRVS,  CP-23  and  CTC-808RV, you have to remove it from the Control Panel.
                                                                                                                                     73. System Configuration 3.1. Entering Programming Mode Three  CTC-1041RV  programming modes  are available:  Local  Programming  Mode,  Remote Programming  Mode,  and  via  CTC-835 Handheld Programmer (sold separately).  3.1.1.  Local  Programming  Mode (Optional) From  Idle  mode,  follow  the  steps  below  to enter Local Programming mode.   Step 1.  Plug in the telephone set into LOCAL PROGRAMMING jack located on the rear side of CTC-1041RV. Step 2.  Pick up the handset.   RED LED lights up. Step 3.  Enter default ACCESS CODE, 1111 followed by #.  Step 4.   CTC-1041RV will emit 2 short beeps and the red LED starts to flash, indicating it is in Programming Mode.  Step 5. Proceed to program system by referring to the Commands in section 3.2 Programming Your 1041RV. <<NNOOTTEE>>   Local programming is prohibited when AC Power fails.  The first digit of Access Code must be entered  within  15  seconds,  otherwise CTC-1041RV will exit automatically.  To  exit  Programming  mode,  enter  99 followed  by  #,    or  place  the    handset on  hook,    or    disconnect  the Programming telephone set.    3.1.2. Remote Programming Mode To  allow Remote  Programming, there  are  two options  for  CTC-1041RV  to  answer  the incoming calls. (1) Auto Answering by ring count (2) Dial in twice (Ring Count disable) The  two  options  are  set  by  Command  #41. Please  refer  to  Command  41  under  section 3.2 Programming your 1041RV.  3.1.2.1. Auto Answering by Ring Count By  using  Command  41,  you  can  set  the number  of  rings  for  CTC-1041RV  to  answer (20-Rings is set as factory default).   Step 1.  Dial CTC-1041RV and wait for CTC-1041RV to answer. Step 2.  Enter  1111  (default  4-digit  Access Code) followed by #, via the phone set.   Step 3.  CTC-1041RV  will  respond  with  two quick  beeps to  indicate  it  is  ready  for Remote Programming. The RED LED will flash as a visual indication. Step 4.  You are now in Programming Mode. Proceed to program by referring to the Command  in  section  3.2 Programming Your 1041RV.  3.1.2.2. Dial in Twice (Ring Count Disable) If  00  is  set  in  Command  41,  it  means  CTC-1041RV  is  disabled  to  auto  answer  the incoming  calls  by  ring  count.  If  Remote programming is  required,  you  will  need  to  call CTC-1041RV twice. Step 1.  Dial  CTC-1041RV  and  hang  up  after first 2 rings, wait for another 8-20 sec then  call  again.  CTC-1041RV  will answer  the  call  on  the  first  ring.  You will  enter  the  Remote  Programming Mode  after  the  first  ring  from  the  2nd call. Step 2.  Enter 1111  (the  default 4-digit  Access Code) followed by #, via the phone set.   Step 3.  CTC-1041RV  will  respond  with  two quick  beeps to  indicate  it  is  ready  for Remote  Programming  Commands.  The  RED  LED  will  flash  as  a  visual indication. Step 4.  You are now in Programming Mode. Proceed  to  program  by  referring  to the  Command  in  section  3.2 Programming Your 1041RV.  <<NNOOTTEE>>   The first digit of Access Code must be entered  within  15  seconds,  otherwise CTC-1041RV will exit automatically.
                                                                                                                                     8 To  exit  Remote  Programming  mode, enter 99 followed by #.  3.1.3. CTC-835 Programmer CTC-835  is  a  powerful  local  &  remote handheld  programming  tool  (sold  separetely) that features a built-in keypad and LCD display to  help  you  to  program  the  medical  alarm panels  effeciently  and  conveniently.  It  also features  Once-for-All  Uploading,  which allows  you  program  on  a  computer  via  the supplied  Pilot  software  and  you  can  then upload  all  the  settings  to  the  medical  alarm panel simultaneously with a single mouse click. For  detailed  usages,  please  refer  to  the Operation Manual of CTC-835 Programmer.                    3.2. Programming Your 1041RV   How to enter Commands? Please  make  sure  CTC-1041RV  is  in Programming  Mode  (RED  LED  flashes continuously)  before  trying  any  CTC-1041RV  Command  Functions.  Please  refer to  section  System  Configuration,  Entering Programming Mode.  Follow the protocol below to command CTC-1041RV: CC # DTMF ACK Function Selection # DTMF ACK 1.  2. 3.  4.  5. 6. 1.  CC = 2-digit DTMF Command 2.  # = Termination of the DTMF Command 3.  ACK = DTMF Command Acknowledgement from CTC-1041RV  Short beep: Command succeeded Long beep: Command failed 4.  Function Selection = According to  different Command you will have different entering in this part, e.g. Tel. Number, Account number, etc. 5.  # = Terminates Function Selection 6.  ACK = Function Selection Acknowledgement from CTC-1041RV  Short beep: Function Selection succeeded Long beep: Function Selection failed  Follow the Command Steps to program your CTC-1041RV:  Step 1.  Enter Command number (DTMF Numeric Command, ex. (01), (02)…) Step 2.  Press (#) to terminate the DTMF Command. Step 3.  One short beep will be heard for successful Command entry.
                                                                                                                                     9Step 4.  Enter the desired Command function number. Step 5.  Enter (#) to terminate the Command Operation. Step 6.  CTC-1041RV will emit a short beep, indicating successful programming. The maximum interval between key strokes is 2 minutes. Otherwise, commands will be ignored and  CTC-1041RV will automatically exit to Idle Mode.    Any  erroneous  programming  must  be rectified and program again correctly.   Command 01-04  Telephone Number Programming  Used  to  program  the  1st -  4th  Tel.  numbers respectively.   To program the  1st  Tel. number:  enter  (01) followed by (#). After one short beep, enter (telephone  number)  followed  by  (#).  The 1st Tel. number is programmed successfully.  Likewise, the 2nd, 3rd or 4th Tel. numbers can be programmed using Command (02), (03) or (04) respectively.   <<NNOOTTEE>>   When  entering  the  phone  number, entering () represent a 3-sec. pause. (ex.  Switchboard  system,  extension, etc.)  Up  to  20  digits  including  ()  are allowed for each telephone number. Delete Telephone Number::::  To  delete  the  1st  Tel.  number,  enter  (01) followed by (#), after one short beep, enter another (#). CTC-1041RV will emit another short beep, signaling the 1st Tel. number is erased.  Likewise, you can erase the respective 2nd, 3rd or  4th  Tel.  Numbers,  by  following  the above procedure.     Command 05-06   Select Telephone Number for Alarm Reporting and Status Reporting <<IIMMPPOORRTTAANNTT  NNOOTTEE>>  If  the  Tel.  number  is  selected  in Commands  #5,  #6  and  #7,  then Command  #7  holds  the  top  priority  to overwrite  the  setting.  The  Tel.  number selected  in  Command  #7  will  not  be used for alarm and/or status reporting,    Command  (05):  Select  which  telephone number  (1-4)  is/are  to  be  used  for  Alarm Reporting.   Command  (06):  Select  which  telephone number  (1-4)  is/are  to  be  used  for  Status Reporting.  Available Key-in options: Tel. Number  Function Selection Sequence 1st Tel. #   (1) 2nd Tel. #  (2) 3rd Tel. #  (3) 4th Tel. #  (4) 1st & 2nd Tel. #s  (12) 1st & 3rd Tel. #s  (13) 1st & 4th Tel. #s  (14) 2nd & 3rd Tel. #s  (23) 2nd & 4th Tel. #s  (24) 3rd & 4th Tel. #s  (34) 1st, 2nd & 3rd Tel. #s (123) 1st, 2nd & 4th Tel. #s (124) 1st , 3rd & 4th Tel. #s (134) 2nd, 3rd & 4th Tel. #s (234) 1st,  2nd,  3rd &  4th  Tel. #s (1234)  Factory  default  is  set  as  (1234).  Alarm  & Status will be reported to all of 4 Telephone Numbers.
                                                                                                                                     10<<NNOOTTEE>>   The  Tel.  number  selected  in Command  #7  will  not  be  used  for alarm and/or status reporting, even if it is selected in command #5 and/or #6.  When  multiple  Tel.  numbers  are selected,  CTC-1041RV  will  always dial in respective programmed order.   The latest Command (05-06) setting(s) will  overwrite  any  previously  enter setting(s).  Command 07   Select Telephone Number for Non-emergency call  This  command  is  used  to  select  which telephone  number  will  be  used  for  non-emergency call.  The  selected  Tel.  number  will  not  be  used for alarm and/or status reporting, even if it is selected in command #5 and/or #6.  Available key-in options: Tel. Number  Function Selection Sequence Disable  (0) 1st Tel. #   (1) 2nd Tel. #  (2) 3rd Tel. #  (3) 4th Tel. #  (4)  Factory default is set as (0) disable. Alarm &  Status  will  be  reported  to  all  of  4 Telephone Numbers.  Please  refer  to  section  4.1.2  for  more information.       Command 10-14  Account Number Programming   Commands  (10-14)  are  used  to  set  the account number for the telephone numbers used for Digital Reporting.  Command  (10):  Set  the  same  account number for all telephone numbers.   Command  (11-14):  Set  the  account numbers  for  the  1st-4th  Tel.  numbers  used for Digital Reporting respectively.  In (Function Selection) key in 4 or 6 digit Account Number.    Command 20-24  Reporting Method   Commands  (20-24)  are  used  to  program the  Alarm  reporting  method  for  each  Tel. Number.  Command  (20): Program  the  same  Alarm Reporting Method for all 4 Tel. Numbers.  Command  (21-24):  Program  the  alarm reporting  method  for  the  1st-4th  Tel. Numbers respectively.  Available Options: Method  Function Selection  Digital Reporting Method (0)  Contact ID (1)  Scancom (2)  Tunstall Speech Method   (3)  Open Two-way communication    (0), Contact ID, is set as factory default for all 4 telephone Numbers. <<NNOOTTEE>>   The latest Command (20-24) setting(s) will  overwrite  any  previously  entered setting(s).  If  any of Digital Reporting Methods is selected: Once  alarm  or  emergency  data  is successfully transmitted, CTC-1041RV
                                                                                                                                     11will  automatically  enter  specific Follow-On  and/or  Call  Back  Mode  as specified by Command (38).  If Speech Method is selected: After  the  dialing  for  alarm/emergency trigger  is  successful,  CTC-1041RV opens a two-way voice communication between the  Call Recipient  and  CTC-1041RV  for  1-10  minutes  (set  by Command #46).  If  the  Call  Recipient  needs  more  talk time,  they  can  press  any keys  except 9 on their phone set to add another 1-10 minutes (set by Command #46).  To  terminate  the  call,  press  (9)  or RESET BUTTON on CTC-1041RV.  Command 31  Ringer Enable for Incoming Calls  CTC-1041RV can be programmed to emit a ring  tone  as an audio alert,  or  silent for incoming calls. Function Selection Result (0)  OFF  (Ring Tone Disable) (1)  ON (Ring Tone Enable)   Factory Default is set as (0), OFF.  <<NNOOTTEE>>   If  the  function  is  set  to  ON,  you  can answer  the  incoming  call  by  pressing the RED  HELP  BUTTON or Pendant Button.  The  time-out  period  for  the  incoming call  is  1  to  10  minutes  (set  by Command  46).  During  the communication,  CTC-1041RV  will emit  two  beeps  via  the  telephone handset  to  alert  the  call  recipient  the remaining time of 20 & 10 sec.  Press  any  DTMF  keys  (except DTMF#9) can extend another  1  to  10 minutes (set by Command 46)    To  terminate  the  incoming  call:  (1) press the green reset button on CTC-1041RV;  or,  (2)  press  DTMF  #9  from the call recipient’s end.    Command 32  Audible Fault Alert   CTC-1041RV  can  be  programmed  to  emit detected and existent Fault Alert Beeps at every 30 sec. Function Selection Result (0)  OFF (No Warning Beep) (1)  ON                (With Warning Beep)  Factory Default is set as (0), OFF.   The fault  situations  include AC failure,  line failure or battery damage.   Command 33  Help Arrived Signaling  This function is only available for the digital Contact ID reporting method.   This  function  will  be  activated  in  the following situations:    When the Red Help Button is pressed.   When  the  button  on  WTRVS  or  Fall Sensor is pressed.   When a fall is detected.   When  Night  Switch’s  Red  Button  is pressed.  It  is  used  for  the  Monitoring  Center personnel to confirm if the help has arrived for the user or not.  If Help Arrived Signaling is set to ON, once the  Alarm  Reporting  is  completed,  the RED HELP BUTTON will start to flash.  Press the GREEN RESET BUTTON when the  Help  arrives,  and  CTC-1041RV  will report  to  monitoring  center  and  the  RED BUTTON will stop flashing.  If  Help  Arrived  Signaling  is  set  to  OFF, once  the  Alarm  Reporting  is  completed, CTC-1041RV will return to idle mode.
                                                                                                                                     12Function Selection Result (0)  OFF  (Disable) (1)  ON   (Enable)  Factory Default is set as (1), ON.  <<NNOOTTEE>>   If  the  green  RESET  button  is  not pressed  within  the  period  set  by Command  67  (Help  Arrived  Timer), CTC-1041RV  will  send  the  alarm report  to  summon  help  again  and inform  the  Monitoring  Center  that  no help  has  arrived  within the  period  set by the Help Arrived Timer.   Command 33 (Help Arrived Signaling) has to be set as ON for Command 67 (Help Arrived Timer) to be activated.     If  help  has  not  arrived after  4  retries, CTC-1041RV  will  dial  the  telephone number set by Command 75 and open two-way communication when the call is answered.  Command 34  Emergency Button Enable  The  RED  HELP  BUTTON  can  be  enabled or  disabled  to  send  an  Emergency  alarm report:  Function Selection  Result (0)  OFF (Deactive) (1)  ON (Active)   Factory Default is set as (1), ON.  <<NNOOTTEE>>   When  this  function  is  programmed  as OFF,  the  RED  HELP  BUTTON  is deactivated.  When  this  function  is  programmed  as ON,  the  RED  HELP  BUTTON  is activated.  When  pressed,  it  will  send an  Emergency  alarm  report  to  the Monitoring Station.     Command 35 Silent Mode  CTC-1041RV can be selected to operate in Silent  Mode.  This  will  mute  all  normal operation  warning  beeps,  key  tone  and ring. <<NNOOTTEE>>   In  silent  mode,  the  speaker  still functions  normally  for  two-way  voice communication.    Function Selection  Result (0)  ON (Silent) (1)  OFF (Normal)  Factory Default is set as (0), OFF.   Command 37  AC Fault Report  The  CTC-1041RV  can  be  programmed  to send  a  Fault  Report  when  an  AC  power failure is detected. Function Selection Result (0)  OFF  (Send No Report) (1)  ON (Send Report)   Factory Default is set as (1), ON.  <<NNOOTTEE>>   Reporting  will  only  be  made  after  a continuous  one  hour  of  AC  Fault condition is detected.
                                                                                                                                     13Command 38 Follow-On & Call-Back Function  The  Command  is  available  for  Digital Reporting Methods (when Command #20 - #24 is set as (0), (1) or (2). Function Selection Result (0)  Follow-On (1)  Call-Back (2)  Follow-On & Call-Back  Factory Default is as (0), Follow-On.   When  this  function  is  programmed  as  (0), after  a  successful  alarm  reporting (triggered  by  pressing  the  Help  button  on the  Medical  Panel)  to  the  Monitoring Center,  CTC-1041RV  will  automatically enter the  Follow-On  mode as  specified  by Command (45). If the alarm is triggered by a  Talking  Pendant  (WTRVS),  the  system will  automatically  enter  “Wait  for Command” mode  (see  Command  45)  and wait for the DTMF 2 signal pressed by the Monitoring  Center  to  set  up  two-way communication  between  WTRVS,  the Monitoring  Center  and  all  CTC-808RVs learned  into  the  system.  If  the  alarm  is triggered  by  CTC-808RV,  the  system  will automatically  enter  “Wait  for  Command” mode (see Command 45) and wait for the DTMF  2  signal  pressed  by  the  Monitoring Center  to  set  up  two-way  communication between  the  Monitoring  Center  and  all CTC-808RVs learned into the system.     When  this  function  is  programmed  as  (1), after a successful alam reporting (triggered by pressing the Help button on the Medical Panel)  to  the  Monitoring  Center,  CTC-1041RV will automatically hang up the line and start a 5-minute waiting period to auto answer any incoming phone calls from the Monitoring  Center.  The  Monitoring  Center personnel  should  enter  an  authorized access code (default: 1111), followed by (#) to  set  up  the  two  way  communication between  CTC-1041RV  and  the  Monitoring Center.  If  the  alarm  is  triggered  by  a  Talking Pendant (WTRVS), the system will wait for an  authorized  access  code  (default  1111) followed by (#) during the 5-minute waiting period  to  open  two-way  communciation between  WTRVS,  the  Monitoring  Center and  all  CTC-808RVs  learned  into  the system. If  the  alarm  is  triggered  by  CTC-808RV, the  system  will  wait  for  an  authorized access code (default 1111) followed by (#) during the 5-minute waiting period to open two-way  communciation  between  the Monitoring  Center  and  all  CTC-808RVs learned into the system.  When  this  function  is  programmed  as  (2), after  a  successful  alarm  reporting (triggered  by  pressing  the  Help  button  on the  Medical  Panel)  to  the  Monitoring Center,  CTC-1041RV  will  automatically enter the  Follow-On  mode as  specified  by Command (45). If the alarm is triggered by a  Talking  Pendant  (WTRVS),  the  system will  automatically  enter  “Wait  for Command” mode  (see  Command  45)  and wait for the DTMF 2 signal pressed by the Monitoring  Center  to  set  up  two-way communication  between  WTRVS,  the Monitoring  Center  and  all  CTC-808RVs learned  into  the  system.  If  the  alarm  is triggered  by  CTC-808RV,  the  system  will automatically  enter  “Wait  for  Command” mode (see Command 45) and wait for the DTMF  2  signal  pressed  by  the  Monitoring Center  to  set  up  two-way  communication between  the  Monitoring  Center  and  all CTC-808RVs learned into the system.      Once Follow-On Mode is  terminated, CTC-1041RV  will  automatically  start  a  5-minute waiting period to auto answer any incoming phone calls from the Monitoring Center. The Monitoring  Center  personnel  should  enter an  authorized  access  code  (default:  1111), followed  by  (#)  to  set  up  the  two  way communication  between  CTC-1041RV  and the  Monitoring  Center.  If  the  alarm  is triggered  by  a  Talking  Pendant  (WTRVS), the  system  will  wait  for  an  authorized access  code  (default  1111)  followed  by  (#) during  the  5-minute waiting  period  to  open two-way  communciation  between  WTRVS, the Monitoring Center and all CTC-808RVs learned  into  the  system.  If  the  alarm  is triggered  by  CTC-808RV,  the  system  will wait for an authorized access code (default 1111)  followed  by  (#)  during  the  5-minute waiting  period  to  open  two-way communciation  between  the  Monitoring Center  and  all  CTC-808RVs  learned  into the system.  <<NNOOTTEE>>
                                                                                                                                     14 During  two-way  communication,  you can use DTMF command to switch the communicating method. Please refer to section 4.2. Alarm Activation.   The first digit of Access Code must be entered  within  15  sec.  Otherwise, CTC-1041RV  will  disconnect  the  call automatically.  To terminate the call, press DTMF (9) or RESET BUTTON on CTC-1041RV.  If  the  5-minute  waiting  period  is  up, CTC-1041RV  will  automatically  exit this  waiting  mode  and  return  to  idle mode.  Command  #41  (Auto  Answer  for Remote Programming) will not be able to  proceed  during  the  5-mins  Call-back time.  Command 39  Dialing Mode  This function is for you to select the dialing method of your telecommunications.   There are two dialing methods available for user: Function Selection Result 0  TONE 1  PULSE  Factory Default is set as (0), Tone.  Command 40  Set Access Code  The  Access  Code  is  used  to  enter Programming  Menu  (locally  or  remotely), and the Call-Back Function.  It  consists  of  4  digits  and  has  been  set  to (1111)  as  factory  default.    Before  you  set your  own  Access  Code, (1111)  must  be keyed in.  To  set  a  new  Access  code;  enter  the desired  (4-digit  number)  in  Function Selection.  Command 41  Auto Answer for Remote Programming  CTC-1041RV  can  be  programmed  to  auto answer  incoming  phone  calls  after  a  pre-set  number  of  rings  have  been  reached. The  number  of  rings  range  from  (00)  (no auto answer) to (32) rings.    Function Selection Result (00)  OFF (01) - (32)  ON  Factory Default is (20) Rings. <<NNOOTTEE>>   If  00  is  selected,  it  means  CTC-1041RV  cannot  auto-answer  the  call by  ring  count.  If  you  want  to  do Remote  programming,  please  follow the  Remote  Programming  method described in System  Conifuration,  I. Entering  Programming  Mode:  2. Remote Programming Mode.  Command 43  Periodic Test Call   CTC-1041RV can be programmed to make test calls periodically from (00) (no test call) to every (1) - (7) or 30 days:    Function Selection Result (0)  OFF (1) - (7)  1 - 7 DAYS (8)  30 DAYS  Factory Default is set as (0), OFF.  <<NNOOTTEE>>     Whenever  programming  mode  is accessed, CTC-1041RV  will  reset  the Periodic Test Call timer.    Periodic  Test  Call  will  only  function  with  telephone  numbers  assigned  to Digital reporting method in Command 20-24.
                                                                                                                                     15Command 44  Mobility Timer This function  monitors user  movement  around the  premises and sends an  inactivity  report to the  Monitoring  Center  if the  user  fails to  reset the inactivity timer.  This  will  disable  or  enable  the  Inactivity Timer with selectable count down periods.  Options are: Function Selection  Result  (0)  DISABLE (1)  12HR (2)  24HR   Factory Default is set as (0), DISABLE.  <<NNOOTTEE>>   The Mobility Timer counting down can be reset by: 1.  Pressing  the  RESET  button  on CTC-1041RV, or, 2.  Movement  detected  by  PIR Detector  When  Mobility  Timer  expires  and  no reset  signal  is  received,  CTC-1041RV starts  to  emit  one  long  beep  every  5 minutes  to  alert  the  user.  After  30 minutes, if reset signal is not received, a mobility alarm reporting will be made.   The  reporting  method  for  mobility alarm  is  the  same  as  the  emergency alarm. The report will be sent based on your reporting methods.  When (0) is selected, no code is sent to Monitoring Center.  When  CTC-1041RV  is  in  idle  mode, press and hold the green reset button for  16  seconds,  until  you  hear  a  long beep.  Then  release  the  button;  the Mobility function will be disabled.  Command 45  Follow-On Mode Choice  This Command is only available for Digital reporting with Command #38 set as (0) or (2).  It  is  used  to  select  the  Follow-On  Choice for CTC-1041RV after it has made a report to the Monitoring Center.    After reporting,  CTC-1041RV  can  wait for further  commands,  or  enter  a  Two-Way Full  Duplex  Communication,  or  Listen-In Half  Duplex  Communication  immediately according  to  the  setting  under  this command: Function Selection  Result (0)  WAIT  COMMAND (1)  LISTEN (2)  TWO WAY  Factory Default is set as (2), TWO WAY.  <<NNOOTTEE>>   When  (0) is  selected,  after  CTC-1041RV  has  made  a  report  to  the Monitoring  Center,  it  will  wait  for  1-10 minutes  (set  by  Command  46),  and then follows the  DTMF commands that are  received  from  the  Central Monitoirng Station for action.    If  no  command  is  received  after  the waiting  period,  the  system  will automatically return to Idle mode.  When  (1) is  selected,  after  CTC-1041RV  has  made  a  report  to  the Monitoring  Center,  it  will  automatically enter  Listen-In  Half  Duplex  for  1-10 minutes (set by Command 46) allowing the  Monitoring  Center  Personnel  to listen  in  to  what  is  happening  on  the other side.  When  (2)  is  selected,  after  CTC-1041RV  has  made  a  report  to  the Monitoring  Center,  it  will  immediately enter  a  Two-way  Full-duplex Communication  mode  for  1-10 minutes  (set  by  Command  46),  that gives  the  user  the  ability  to  speak directly  with  the  Monitoring  Center Personnel.  If  either  Scancom  or  Tunstall  reporting format  is  selected,  CTC-1041RV  will ignore Command #45  selections.  It  will always  open  a  Two-way  voice  for Follow-On choice.
                                                                                                                                     16 If  an  alarm  is  triggered  by  WTRVS  or CTC-808RV,  Monitoring  Center personnel will have to press DTMF 2 for over  1  second  to  open  two-way communication  regardless  of  the Follow-On choice you have set.        Command 46  Follow-On Mode & Two-Way Period   This  command  is  used  to  program  the allowable  time  duration  for  Follow-On mode choice (Commend  #45)  &  Two-way voice  communication  period  (Speech mode). It can be set from (01) (1 minute) - (10) (10 minutes).     Function Selection Result (01)  1 MINUTE  (02)  2 MINUTES (03)-(10)  3-10  MINUTES   Factory  default  is  set  as  (02)  2  minutes. The allowable time duration for either Wait Command,  Two-way,  Listen-In  Only  or Two-way  voice  comminucation  in Speech  mode  is  two  mins.  During  the  2-min  period,  CTC-1041RV  will  emit  two beeps  via  the  telephone  handset  to  alert the call recipient the remaining time of 20 & 10  sec.  Pressing  assigned  DTMF  key  can extend another 1-10 minute(s).  Command 47   Off-Set Time    After the Control Panel‘s power is supplied, the  time  of  the  Check-in  Report  starts calculating.   According  to  the  setting  of  Off-Set  Time, the  Control  Panel  will  send  Check-in Report  once,  and  then  send  report according  to  the  setting  of  Command  43  Test call. Function Selection  Result (1)  1 Hour  (2)  2 Hour (3)  3 Hour (4)  4 Hour (5)  8 Hour (6)  12Hour   Factory default is set as (1) 1 Hour. When the  Off-Set  Time  is  reset  in  programming Mode,  the  time  of  the  Off-Set  period  will recalculate.   Off-Set time Report will be sent only once, and then the Control Panel sends Check-in Report  according  to  setting  of  period  test call,  unless  the  Control  Panel  restarts  or the Off-Set time is reset.  Command 49   Supervision  This function is not available for the digital Scancom reporting method.    This  option  is  used  to  enable  system Supervision function. Once enabled, CTC-1041RV will be able to receive the check-in  signals from  Wrist Pendants  (WTR-) to indicate their proper functioning. Function Selection  Result (0)  Disable (1)  4 Days  (2)  5 Days (3)  6 Days  (4)  7 Days (5)  8 Days (6)  9 Days (7)  10 Days (8)  30 Days   Factory  default  is  set  as  (0)  Disable.  No code is sent to Monitoring Center.   When the supervisory timer expires and no supervision  signal  is  received  from  WTR-, the  supervisory  alarm  reporting  will  be made.   The reporting method for supervisory alarm is  the  same  as  the  emergency alarm.  The report will be sent based on your reporting
                                                                                                                                     17methods.   The  supervision  function  does  not  cover WTRVS.   Command 66 Set Guard Time Delay Time for Fall Sensor   This  command  is  used  to  set  the  guard time delay time for fall sensor.   CTC-1041RV can be programmed to delay alarm  reporting  (triggered  by  Fall  Sensor) from  (00)  (instant  reporting)  to  (99) seconds.  During this time period, a continuous series of beeps will be emitted to alert user.     If a false alarm is triggered by Fall Sensor, it  can  be  cancelled within the  Guard Time Delay.  Function Selection  Result (00)  INSTANT REPORTING (01) - (99)  DELAY   Factory Default is (15), 15 SECONDS.   <<NNOOTTEE>>    This  command  is  used    if  a  fall  is detected.     If an emergency alarm is triggered by pressing  the  Active  Button  on  Fall sensor, the system will report an alarm immediately.  Command 67 Setting the Help Arrived Timer  This  command  is  used  to  set  the countdown  timer  for  CTC-1041RV  to resend  the  alarm  report  if  no  help  has arrived  after  the  initial  report  is  made (meaning  the  reset  button  has  not  been pressed before the timer expires).   Function Selection  Result (01)-(15)  1-15 MINUTES  Factory default is (15), 15 MINUTES.    <<NNOOTTEE>>     The  Help  Arrived function  (Command 33) must be set as ON for this function to work.  Command 75 Help Not Arrived Call  When  CTC-1041RV  has  sent  an  alarm report  and  help  not  has  arrived  after  4 retries,  CTC-1041RV  will  dial  the  phone number programmed by Command 75 and open  two-way  communication  when  the call is answered.   Enter the (telephone number) followed by (#) to program the telephone number. <<NNOOTTEE>>   When you program the phone number, entering  ()  will  cause  a  3-second pause.  ()  is  for    a  switchboard system, extension, etc.   The  telephone  number  can  contain  up to 20 digits, including ().  The  Help  Arrived  function  (Command 33) must be set as ON for this function to work.  CTC-1041RV  only  dials  this  telephone number  once.  If  this  phone  call  fails, CTC-1041RV will not try again.   Command 80-84  Remove Devices   CTC-1041RV  can  be  programmed  to remove  ALL  previously  learnt  devices  by entering (80) followed by  ( ). The  system will  emit  an  acknowledging  beep  over  the phone for the user.  Command (81) is used to remove Pendant # 1 (learnt-in by Command 91)   Command (82) is used to remove Pendant # 2 (learnt-in by Command 92).    Command  (83)  is  used  to  remove  Silent Wrist (learnt-in by Command 93).    Command  (84)  is  used  to  remove  Other Devices (learnt-in by Command 94).  <<NNOOTTEE>>
                                                                                                                                     18 To remove a talking  pendant (WTRVS) or CTC-808RV from the Contorl Panel, you have to remove it from the Control Panel  first  and  then  restore  the WTRVS  or  CTC-808RV  to  factory default.   If  the  Pendant(s)  you  use  Commands 80-84 to remove includes any WTRVS or CTC-808RV, you will need to wait 5 to  10  seconds  for  the  system  to  emit an  acknowledging  beep  over  the phone.   Commands 91   Learn-In Pendant #1   Only one Pendant can be learnt into CTC-1041RV by using Command #91.  This  command  is  only  used  for  learning WTR- Series, Fall Sensor, WTRVS, CP-23 or CTC-808RV.   If  you  have  learned  one  device  into  the system  by  using local  learning method  (as mentioned  in  2.1  section),  you  are  not allowed  to  use  Command  91  to  learn  in another device.   For learning Pendant #1:  Step 1: Enter 91 + # on the phone set, then a  short  beep  will  be  heart  via  the phone set.  Step 2: Press the Pendant Button within 60 sec.   Learning  can  only  be  completed within the signal reception range of CTC-1041RV.  If  no  signal  is  received  within  60 sec,  CTC-1041RV  will  emit  a  long beep  and  automatically  returns  to Programming mode.  Step  3:  CTC-1041RV  will  emit  2  beeps to indicate that Pendant #1 is learnt-in successfully.  Adding  a  Pendant  for  a  second time  is  prohibited  unless  it  is removed from the system first.   If  one  long  beep  is  emitted instead of 2 beeps, it indicates:   The device has already been learnt-in.   Another device has been learnt-in before.  Commands 92   Learn-In Pendant #2   Only one Pendant can be learnt into CTC-1041RV by using Command #92.  This  command  is  only  used  for  learning WTR- Series, Fall Sensor, WTRVS, CP-23 or CTC-808RV.   If  you  have  learned  one  device  into  the system  by  using local  learning method  (as mentioned  in  2.2  section),  you  are  not allowed  to  use  Command  92  to  learn  in another device.   For learning Pendant #2:  Step 1: Enter 92 + # on the phone set, then a  short  beep  will  be  heart  via  the phone set.  Step 2: Press the Pendant Button within 60 sec.   Learning  can  only  be  completed within the signal reception range of CTC-1041RV.  If  no  signal  is  received  within  60 sec,  CTC-1041RV  will  emit  a  long beep  and  automatically  returns  to Programming mode.  Step 3: CTC-1041RV  will  emit  2  beeps  to indicate that Pendant #2 is learnt-in successfully.  Adding  a  Pendant  for  a  second time  is  prohibited  unless  it  is removed from the system first.   If  one  long  beep  is  emitted instead of 2 beeps, it indicates:   The device has already been learnt-in.   Another device has been learnt-in before.  Commands 93   Learn-In Silent Pendant   Only one Silent Pendant (WTR- Series, Fall   Sensor,  WTRVS,  CP-23  or  CTC-808RV) can  be  learned into CTC-1041RV  by  using Command  #93.  When  CTC-1041RV received  the  alarm  signal  from  the  Silent
                                                                                                                                     19Pendant,  CTC-1041RV  will  not  emit  any warning beeps during Reporting.  For learning Silent Pendant:  Step 1: Enter 93 + # on the phone set, then a  short  beep  will  be  heart  via  the phone set.  Step 2: Press the Pendant Button within 60 sec.   Learning  can  only  be  completed within the signal reception range of CTC-1041RV.  If  no  signal  is  received  within  60 sec,  CTC-1041RV  will  emit  a  long beep  and  automatically  returns  to Programming mode.  Step 3: CTC-1041RV  will  emit  2  beeps  to indicate  that  Silent  Pendant  is learnt-in successfully.  Adding  a  Pendant  for  a  second time  is  prohibited  unless  it  is removed from the system first.   If  one  long  beep  is  emitted instead of 2 beeps, it indicates:   The device has already been learnt-in.   Another device has been learnt-in before.  Commands 94   Learn-In Device  Up  to  7  devices  can  be  learnt  into  CTC-1041RV by using Command #94.  The available devices that can be  learnt-in    Command #94 are:   PIR Sensor  ----- PIR   Smoke Detector ---- SD   Carbon Monoxide ---- CO   Fixed Panic Button ---- PB   Wrist Transmitter ---- WTR   Pendant Transmitter ---- WTR   Water Sensor ---- WS    Fall Sensor ---- FS   Talking Pendant ---- WTRVS   Call Point ---- CP-23   Voice Satellite ---- CTC-808RV Step 1: Enter 94 + # on the phone set, then a  short  beep  will  be  heard  via  the phone set.  Step  2:  Press  the  learn  button  on  the device within 60 sec.   Learning  can  only  be  completed within the signal reception range of CTC-1041RV.  If  no  signal  is  received  within  60 sec,  CTC-1041RV  will  emit  a  long beep  and  automatically  returns  to Programming mode.  Step  3:  CTC-1041RV  will  emit  2  beeps to indicate  the  device  is  learnt-in successfully.  Adding  a  Pendant  for  a  second time  is  prohibited  unless  it  is removed from the system first.   If  one  long  beep  is  emitted instead of 2 beeps, it indicates:   The device has already been learnt-in.   When an 8th device is attempted to learn-in. Step  4:  Repeat  steps  1-3  until  all  devices are learnt-in. <<NNOOTTEE>>   Adding  a  device  for  a  second  time  is prohibited  unless  it  is  removed  from the system first.   Command 98   Factory Default Reset    To  Reset  CTC-1041RV  to  factory  default settings, enter (98) and then (#).    After one short beep, continue by entering ()  and  then  end  with  another  (#),  one beep will be heard for termination.  Once  the  Factory  Default Reset  is executed,  all  the  programmed  data  is returned  to  its  default  value  and  all  the devices  that  have  been  learnt-in  are removed. You have to do the programming and learn-in the device one by one again.  Command 99   Exit Programming Mode
                                                                                                                                     20 Enter  (99)  and  (#),  after  one  short  beep, CTC-1041RV exits the Programming Mode and returns to idle mode.                                     4. Operation 4.1. Idle Mode When  the  system  is  in  Idle  Mode,  CTC-1041RV  is  ready  to  execute  the  following functions:  4.1.1.  Auto-Answer  Incoming  Phone Calls This function is only available when Command #31 is set as ON (factory default is OFF).   For  an  Incoming  telephone  call,  CTC-1041RV will emit cycles of 2 quick beeps.   User  can  answer  the  call  either  by pressing the Pendant Button or the RED HELP BUTTON on CTC-1041RV.   The  user  can  also  remotely  answer  the call  by  pressing  the  Pendant  Button  on WTRVS or by pressing the Emergency or Service button on CTC-808RV.   Once CTC-1041RV answers the call, it will open  a  Two-Way  Voice  Communication. The RED HELP BUTTON illuminates.    In  the  “Two-Way”  and  “Talk  Only” communication  modes,  press  (6)  or (4) to increase or decrease the levels of speaker volume.  <<NNOOTTEE>>   If levels of speaker volume can only be adjusted  in  the  two-way  or  talk  only communication  mode,  the  adjusted value will be kept at next use.   The  value  of  speaker  volume  ranges from 1 to 8 and the default value is set as (5).   If  communication  is  set  up  between  WTRVS/CTC-808RV  and  the emergeny  call  recipent,  the  speaker volume level cannot be adjusted.   To  hang-up,  press  and  hold  the Pendant Button for 5-8 seconds again or the RESET button on CTC-1041RV.  1 to 10 minutes (set by Command 46) is allowed for each call.
                                                                                                                                     214.1.2. Non-Emergency Speech Call   This  function  is  only  available  when Command #7 is programmed. Making  a  Non-Emergency  Call  from  CTC-1041RV Step 1.  From  Idle  mode,  press  and  hold the RESET  button  for  3  seconds  until CTC-1041RV emits a short beep.   Step 2.  Release  the  button  and  one  short beep  will  sound.    CTC-1041RV  dials the  phone  number  entered  in Command #7. Making  a  Non-Emergency  Call  from  CTC-808RV Step  1.    Hold  the  green  Service  button  on CTC-808RV  for  5  seconds.  CTC-808RV will emit a short beep.  Step  2.  CTC-1041RV  will  dial  the  phone number  programmed  via  Command #7.  The  dial  done  can  be  heard  on CTC-808RV.  Step  3.  When  the  call  gets  through,  CTC-808RV  will  open  two-way  voice communication.  <<NNOOTTEE>>   When  5  short  beeps  (warning  beeps)  sound    instead  of  a  short  beep,  it  means CTC-1041RV is not in idle mode and it  is not  allowed  to  use  non-emergency  call function.   If  a  non-emergency  call  is  made  from CTC-1041RV, two-way communication will be conducted via CTC-1041RV.   If  a  non-emergency  call  is  made  from CTC-808RV,  two-way  communication  can be  conducted  via  all  CTC-808RVs  in  the system.  Step 3. If  the  dialing  succeeds,  CTC-     1041RV  will  open  a  two-way  voice communication  between  the  call recipient and CTC-1041RV  for  1 to  10 minutes (set by Command 46). The Red button backlight will illuminate during the communication. <<NNOOTTEE>>   If  the  dialing  fails,  CTC-1041RV  will  not retry.  Press  Reset  button  can  stop  and  cancel the dialing & call at any time. Step 4. At the last 20 & 10 sec, CTC-   1041RV will  emit  two  beeps  via  the  telephone handset to alert the call recipient. If the Call  Recipient  needs  more conversation  time,  press  any  DTMF key (except 9) can add another 1 to 10 minutes (set by Command 46).  Step 5.  Press  DTMF  9  or  Reset  button  to terminate  the  call.  The  Red  button backlight  dims  and  CTC-1041RV returns to idle mode.   4.1.3. AC Power Check Up   If  the AC  Power failure  is detected for 10 seconds or longer, the GREEN LED starts to flash as a visual warning to the user.   Once the AC Power resumes, the GREEN LED turns steady on again.   If  the  AC  Power  failure  lasts  for  an  hour, CTC-1041RV  will  send  an  AC  Failure report to the Monitoring Center.    After  the  Power  restoration  lasts  more than one hour, CTC-1041RV will report AC Restore to the Monitoring Center.   4.1.4. CTC-1041RV Low Battery   CTC-1041RV  is  unable  to  detect  its Battery  condition  at  first  30  minutes  after powering up.      When the battery low condition lasts for 4 - 6  mins,  CTC-1041RV  will  report  to  the Monitoring  Center  and  the  GREEN  LED flashes slowly.   If  Low  Battery  condition  persists,  CTC-1041RV will emit 2 short beeps every hour.   Press  the  RESET  button  to  clear  the warning  beeps,  and  the  LED  returns  to steady ON.   After  the  battery  voltage  is  restored  and lasts for 12 hours, CTC-1041RV will send Battery  Restore  report  to  Monitoring Center  and  the  GREEN  LED  returns  to steady ON.  4.1.5. CTC-1041RV  Battery Disconnection    CTC-1041RV  can  detect  the  absence  of
                                                                                                                                     22battery in the following cases:   Battery switch OFF   Battery not connected   Battery failure.     When  the  battery  disconnection  lasts  for 10-15 mins, CTC-1041RV will report to the Monitoring  Center  and  the  GREEN  LED flashes slowly.   If  battery  disconnection  persists,  CTC-1041RV will emit 2 short beeps every hour.   The  blinking  status  of  RED  LED  can  be cleared by pressing the “RESET” button.    After the battery is restored and it lasts for 10~15min, CTC-1041RV will send Battery Restore  report  to  Monitoring  Center  and the GREEN LED returns to steady ON.  4.1.6. Devices Low Battery   When CTC-1041RV receives a battery low signal from a particular device, it will report to the  Monitoring Center and  the GREEN LED  will  flash  rapidly  until  the  fault condition is cleared.    In addition, CTC-1041RV will emit 3 short beeps  every  hour.  Press  the  RESET button  on  CTC-1041RV  will  stop  the warning beeps.   If  any  device  Low  Battery  signal  is received  again,  the  LED  and  warning beeps  will  be  performed  accordingly. Press  the  RESET  button  again  to  silent the warning beeps.   After  the  faulty  battery  is  replaced,  CTC-1041RV  will  immediately  send  Battery Restore report to the Monitoring Center for that particular device.  4.1.7.  Automatic  Check-in  Report  = Periodic Test Call   When  CTC-1041RV  is  programmed  to send  a  periodical  check-in  report,  CTC-1041RV  will  report  to  the  Monitoring Center accordingly.   The  Periodic-Check-in  Timer  will  be  reset whenever Programming Mode is entered.    4.1.8. Mobility Timer   In  order to  check the  user’s  well being,  a Mobility  Timer  can  be  set  by  using Command #44.   If  Mobility  Timer  is  set  as  Enable,  a counting down period starts from:   Immediately  after  powering  up  CTC-1041RV    Exit Programming Mode   After  the  pre-set  Timer  expires,  CTC-1041RV  will  emit  a  beep  at  every  5 minutes to notify the user for 30 minutes.   When  the  Mobility  timer  is  not  reset  after 30  minutes,  CTC-1041RV  will  send  a Mobility  Timer  Expired  report  to  the Monitoring  Center  every  30  minutes  until timer is reset.   Mobility  Timer  can  be  reset  by  pressing RESET  button  once  on  CTC-1041RV  or whenever a movement is detected by PIR Detector.   To disable the Mobility Timer function:   Set Command #44 to 0 (Disable), or,    Press and hold the RESET button on CTC-1041RV  for  16  seconds  or longer. <<NNOOTTEE>>   If  no  movement  is  detected  during  preset mobility  time,  CTC-1041RV  will  send  a  CID event code 641 with a fixed zone number 071 regardless  of  the  zones  the  triggered  motion detectors occupy.   Disable  the  Mobility  function  in  idle mode: Step  1:  When  the  system  is  in  Idle  Mode, press  & hold the  Reset Button for 16 seconds. Step  2:  During  the  16-sec  period,  CTC-1041RV will emit one short beep  a double beep  continuous three short beeps  a long beep. Step  3:  Release  the  Reset  Button  when  you hear the last long beep; a short beep will  sound  to  indicate  the  mobility function is disabled. <<NNOOTTEE>>   Please  use  Command  #44  to  enable  the Mobility timer again.
                                                                                                                                     234.1.9. No Pendant Present  This  function  is  only  available  for  the digital Contact ID reporting method.    If  there  is  no  pendent  being  learnt  into CTC-1041RV  30  minutes  after  powering up,  it  will  send  a  No  Pendant  Learnt-in report to the Monitoring Center and repeat every  hour  thereafter,  until  a  pendant  is successfully learnt in. <<NNOOTTEE>>   The  control  panel  will  still  send  No pendant  Learnt-in  report  even  when 1041RV is only Learning WTRVS. But if  WTR  is  learnt  in,  the  control  panel won’t  send  No  pendant  Learnt-in report.   4.2. Alarm Activation   When  an  alarm  is  triggered,  both  RED LED  and  RED  HELP  BUTTON  backlight turn on steadily.    An alarm report can only be canceled by pressing the green reset button on CTC-1041RV. An alarm report cannot be  canceled  by  pressing  buttons  on sensors  such  as  CP-23,  WTRVS3, 808RV,  WTR,  Fall  Sensor  or  Panic Button.    After  two-way  communication  is established,  the  alarm  report  can  be canceled  via  CP-23,  WTRVS3  or 808RV  only  if  it  has  been  triggered by one of these DECT devices.   Confirmation Beeps   Once an  alarm  is triggered, CTC-1041RV will  summon  help  based  on  the programmed  reporting  method.  A continuous  confirmation  beeping  sound (about  1s-on  /  1s-off)  will  be  heard  after CTC-1041RV dials out, indicating that the call  is  in  progress  (regardlss  of  Digital  or Speech Reporting Method).   If  WTRVS  or  CTC-808RV  triggers  an alarm,  WTRVS  or  CTC-808RV  will  emit continuous  confirmation  beeps  (about  1 second on and 1 second off).   Confirmation  beeps  will  be  heard  in  the following situations: <<IIMMPPOORRTTAANNTT  NNOOTTEE>>   When an alarm is triggered by any device (except  for  Talking  Pendant  WTRVS  and CTC-808RV), two-way communication will be set up between the Central Monitoring Station and the Control Panel. If an alarm is  triggered  by  WTRVS  or  CTC-808RV, two-way  communication  will  be  set  up between  the  Central  Monitoring  Station and WTRVS or CTC-808RV.  Alarm  Triggered  by  Talking  Pendant (WTRVS) Press the Active button on a talking pendant to trigger  an  alarm.  Then  you  will  hear  a  talking pendant’s confirming beeps and the beeps will stop  until  a  talking  pendant  receives  a  DTMF command.  If  a  talking  pendant  receives  a DTMF  command,  it  indicates  that  the connection  is  setup  successfully.  While  a talking  pendant  is  triggered,  1041RV’s  Help Button  and  Red  button  will  lighten  until connection ends.    <<NNOOTTEE>>   When an alarm is triggered by Talking Pendant  (WTRVS),  two-way communication will be set up between the  Central  Monitoring  Station,  the Talking  Pendant  and  all CTC-808RVs in the system. A trigger by WTRVS will open  two-way  communication  for  all CTC-808RVs learned in to the system.  When an alarm reporting successfully goes through to CMS, but if no DTMF command  is  received  by  a  talking pendant, after 2.5 minutes, connection will  timeout  and  the  talking  pendant will stop beeping.  When  reporting  to  CMS  fails,  the talking  pendant  will  go  to  retry  cycle and its confirming  beeps will continue until  it receives  a  DTMF  command  or until a retry cycle. Alarm  Triggered  by  Voice  Satellite  CTC-808RV When  you  press  the  Emergency  button  on  a CTC-808RV, an emergency  report will be sent and two-way communication will be opened for ALL  CTC-808RVs  learned into  the  system for 5  minutes.  CTC-808RV’s  green  LED  will  light up during the communication.<<NNOOTTEE>>
                                                                                                                                     24 When an alarm reporting successfully goes  through  to  CMS  but  no  DTMF command  is  received  by  a  CTC-808RV,  connection  time  will  be  up after 2.5 minutes.  When  the  reporting  to  CMS  fails, CTC-808RV  will  enter  the  retry  cycle until it receives a DTMF command.  CTC-808RV’s communication function is  temporarily  suspended  when  CTC-1041RV  is  engaged  in  two-way communication.   Digital Reporting Method After  the  alarm  reporting  is  successfully received  by  the  Monitoring  Center,  CTC-1041RV  will  then  follow  the  choice  of Command  #38,  to  enter  Follow-On  and/or Call-Back mode:  Call-Back Operation   If  Command  #38  is  set  as  1,  Call-Back  or  2,  Follow-On  &  Call-Back; after alarm reporting, it will then wait 5  minutes  for  Monitoring  Center Personnel to call back after reporting.  When  the  Monitoring  Center  calls back  within  this  5-minute  period, CTC-1041RV  will  automatically answers the call after the 1st -2nd rings and  wait  for  proper  Access  Code (default is 1111) entry followed by the (#) key within 15 sec.  Upon  the  correct  Access  Code received, CTC-1041RV will then open a Full-Duplex Communication to allow the  Call  Recipient  to  speak  to  CTC-1041RV directly. You can also use the following DTMF commands to change the speech mode. Enter DTMF (1) to TALK ONLY Enter  DTMF  (2)  to  open  TWO-WAY VOICE COMMUNICATION  Enter DTMF (3) to LISTEN-IN ONLY Enter DTMF (9) to HANG UP  <<NNOOTTEE>>   During the  call  back  period,  enter  the access  code  followed  by  DTMS command  to  open  a  Full-Duplex Communication,  allowing  the  Call Recipient  to  speak  to  CTC-1041RV directly.    If  Command #38  is set  as  0,  Follow-On,  or  2, Follow-On  &  Call-Back,  it  will  then  follow  its settings  as  in  Command  #45,  Follow-On Choice  to  open  Two-way  Voice,  or,  Listen-In, or just waiting for commands.   Follow-On Operation Please note that if  an alarm is triggered by WTRVS or CTC-808RV for follow-on operation, Monitoring Center personnel will have to press DTMF  2  to  open  two-way  communication regardless of the Follow-On choice (Command 45)  you have set.  Then the  Monitoring Center can  remotely  control  CTC-1041RV  by  the DTMF commands listed below.   If  an  alarm  is  triggered  by  any  compatible device  (except  for  WTRVS  or  CTC-808RV) or  by  pressing  the  HELP  button  on  CTC-1041RV,  the system  will respond according to the  preset  Follow-On  mode  (Command  45). During  the  two-way  communication,  the Monitoring  Center  can  remotely  control  CTC-1041RV by the DTMF commands listed below. 1. CONTACT ID FORMAT:   Enter  (2) to open TWO-WAY  VOICE COMMUNICATION    Enter (1) to TALK ONLY   Enter (3) to LISTEN-IN ONLY   Enter (9) or (0) to HANG UP   In  the  “Two-Way”  and  “Talk  Only” communication modes,   press  (6)  or (4) to  increase  or decrease levels of speaker volume.    Press  any  DTMF  key  except  for  the hang-up key (9) or (0) to add another preset communication period. Please note  that  when  a  particular  DTMF key is pressed, its designed shortcut function  will  be  executed  and  the communication  period  will  be extended at the same time. <<NNOOTTEE>>   Enter  (9)  to  hang  up  the  call  and terminate  help  arrived  mode  and callback  mode  when  the  nurse  no longer  needs  help.  In    this  case WTRVS  and/or  CTC-808RV  will  return to idle mode after the call is hung up.
                                                                                                                                     25 Enter (0) to hang up the call only. Help arrived  mode  and  callback  mode  will continue.  WTRVS  and/or  CTC-808RV will remain in callback mode.   f levels of speaker volume can only be adjusted  in  the  two-way  or  talk  only communication  mode,  the  adjusted value will be kept at next use.   The  value  of  speaker  volume  ranges from 1 to 8 and the default value is set as (5).   If  communication  is  set  up  between  WTRVS/CTC-808RV  and  the emergeny  call  recipent,  the  speaker volume level cannot be adjusted.   2. SCANCOM FORMAT:   Enter (2) to TALK ONLY   Enter (1) to LISTEN-IN ONLY   Enter  (3) to open TWO-WAY  VOICE COMMUNICATION   Enter (5) or (0) to HANG UP   Enter ( ) to TOGGLE   In  the  “Two-Way”  and  “Talk  Only” communication  modes,  press  (6)  or (4) to  increase  or decrease levels of speaker volume.    Press  any  DTMF  key  except  for  the hang-up key (5) or (0) to add another preset communication period. Please note  that  when  a  particular  DTMF key is pressed, its designed shortcut function  will  be  executed  and  the communication  period  will  be extended at the same time. <<NNOOTTEE>>   Enter  (5)  to  hang  up  the  call  and terminate  help  arrived  mode  and callback  mode  when  the  nurse  no longer  needs  help.  In    this  case WTRVS  and/or  CTC-808RV  will  return to idle mode after the call is hung up.   Enter (0) to hang up the call only. Help arrived  mode  and  callback  mode  will continue.  WTRVS  and/or  CTC-808RV will remain in callback mode.   If levels of speaker volume can only be adjusted  in  the  two-way  or  talk  only communication  mode,  the  adjusted value will be kept at next use.   The  value  of  speaker  volume  ranges from 1 to 8 and the default value is set as (5).   If  communication  is  set  up  between  WTRVS/CTC-808RV  and  the emergeny  call  recipent,  the  speaker volume level cannot be adjusted.   3. TUNSTALL FORMAT:   Enter (C) to TALK ONLY   Enter ( ) to LISTEN-IN ONLY   Enter  (3) to open TWO-WAY  VOICE COMMUNICATION   Enter (#) or (0) to HANG UP   In  the  “Two-Way”  and  “Talk  Only” communication  modes,  press  (6)  or (4) to  increase  or decrease levels of speaker volume.     Press  any  DTMF  key  except  for  the hang-up key (#) or (0) to add another preset communication period. Please note  that  when  a  particular  DTMF key is pressed, its designed shortcut function  will  be  executed  and  the communication  period  will  be extended at the same time. <<NNOOTTEE>>   Enter  (#)  to  hang  up  the  call  and terminate  help  arrived  mode  and callback  mode  when  the  nurse  no longer  needs  help.  In    this  case WTRVS  and/or  CTC-808RV  will  return to idle mode after the call is hung up.   Enter (0) to hang up the call only. Help arrived  mode  and  callback  mode  will continue.  WTRVS  and/or  CTC-808RV will remain in callback mode.   If levels of speaker volume can only be adjusted  in  the  two-way  or  talk  only communication  mode,  the  adjusted value will be kept at next use.   The  value  of  speaker  volume  ranges from 1 to 8 and the default value is set as (5).   If  communication  is  set  up  between  WTRVS/CTC-808RV  and  the emergeny  call  recipent,  the  speaker volume level cannot be adjusted.    The allowable time duration for Follow-On Period is set by Command #46 (1-10 mins).
                                                                                                                                     26  During Two-way Voice Communication, at 20  &  10  seconds  before  the  Follow-On period expires, CTC-1041RV will emit two beeps  to  alert  both  the  user  and  the Monitoring Center Personnel.   To extend the conversation, the Monitoring Center  personnel  can  press  the  DTMF command again to add another 1-10 mins.   Voice  Communication  can  be  terminated by the following:   DTMF Commands: Contact ID:  9 or 0 Scancom:    5 or 0 Tunstall:       # or 0    The RESET button is pressed.  Automatically  hangs  up  after  the Follow-On Period expires.   Help Arrived Signaling This  function  is  only  available  for  the Contact  ID  digital  reporting  method  and when  the  Help  Arrived  Signaling  function (Command #33) is set as ON.        Help  arrived  mode  will  be  activated after  Contact  ID  code  100,  101  or 120  is  reported.  CTC-1041RV  will start  counting  down  the  Help  Arrive Timer according to the length of time set  by  Command  67.  The  HELP button starts flashing. <<NNOOTTEE>>     Callback  mode  coexists  with  help arrived mode. The Monitoring  Center can  call  back  to  CTC-1041RV multiple  times  and  to  WTRVS  or CTC-808RV once during help arrived mode.  Callback  mode  and  help arrived mode will be terminated at the same  time  when  DTMF  key  (9)  is entered  to  end  two-way communication.    If  the  RESET  button is  not  pressed before  the  timer  expires,  CTC-1041RV  will  send  the  alarm  report again to inform the Monitoring Center that no help has arrived.   If  the  RESET  button is  still  not pressed  after  4 retries  to  resend  the alarm  report,  CTC-1041RV  will  dial the  telephone  number  programmed by  Command  75  and  open  two-way communication  when  the  call  is answered. If the call is not answered, CTC-1041RV  will  end  the  report, retry  no  more,  and  return  to  idle mode.   When  help  has  arrived,  the  RESET button  should  be  pressed  twice quickly to send an alarm reset report to  the  Monitoring  Center.  The  HELP button  stops  flashing  and  CTC-1041RV returns to idle mode   When  help has arrived, pressing the RESET button once will enable CTC-1041RV  to  send  a  Nurse  Present report  to  the  Monitoring  Center.  The HELP button continues to flash. The Help  Arrived  Timer  will  be  reset  and start  counting  down  from  the beginning again.   When  the  nurse  has  completed treatment  for  the  caller,  he/she should  press  the  RESET  button again  to  enable  CTC-1041RV  to send  a  Local  Reset  report  to  the Monitoring Center. The HELP button will  stop  flashing,  the  Help  Arrived Timer  stop  counting  down,  and  the system return to idle mode If the nurse needs more help, he/she should  press  the  HELP  button  to send a Call Assistance report to the Monitoring  Center  to  call  for  more help.   If  the  RESET  button  is  not  pressed again  to  send  a  Local  Reset  report after a Nurse Present report is sent, CTC-1041RV will continue  to resend the  Nurse  Present  report  when  the Help Arrived Timer expires.  If  the  RESET  button  is  not  pressed after  4  retries  to  send  the  Nurse Present  report,  CTC-1041RV  will dial  the  telephone  number programmed  by  Command  75  and open  two-way  communication  when the call is answered. If the call is not answered,  CTC-1041RV  will  end report,  retry  no  more,  and  return  to idle mode. <<NNOOTTEE>>   Two-way voice communication established in help arrived mode can be terminated by pressing  DTMF  9  or  DTMF  0.  If  the  two-
                                                                                                                                     27way  communication  is  terminated  by pressing  DTMF  9,  the  control  panel  will simultaneously end help arrived mode and send event code 1663 to  report  the cancelled  help  arrived  mode.  If  the  two-way  communication  is  terminated  by pressing  DTMF  0,  the  control  panel  will remain in help arrived mode.   Speech Reporting Method   If  Speech  Reporting  Method  is  selected, after dialing, CTC-1041RV will open a two-way  voice  communication  between  the Call  Recipient  and  CTC-1041RV  for  1-10 minutes (set by Command #46).   If  the  alarm  is  triggered  by  Talking Pendent WTRVS, two-way communication will  be  opened  between  the  Monitoring Center,  the WTRVS  and  all  CTC-808RVs in  the  system  after  the  WTRVS  receives an acknowledging DTMF 2 signal from the Monitoring Center.   If  the  alarm  is  triggered  by  CTC-808RV, two-way  communication  will  be  opened between  the  Monitoring  Center  and  all CTC-808RVs  in  the  system  after  CTC-808RV  receives  an  acknowledging  DTMF 2 signal from the Monitoring Center.  <<NNOOTTEE>>   CTC-808RV’s communication function        is  temporarily  suspended  when  CTC-1041RV  is  engaged  in  two-way communication.    At 20 & 10 seconds before the time period expires, CTC-1041RV will emit two beeps via the telephone handset to alert the user.   If the Call Recipient needs more talk time, they can press any keys except 9 on their phone  set  to  add  another  1-10  minutes (set by Command 46).    To  terminate  the  call,  press  the  RESET button  on  CTC-1041RV  or  DTMF  9.  You can  also  press  the  Pendent  Button  on WTRVS or  the  Service  Button  on  CTC-808RV for 5~8 seconds to end the call.   Call Sequence   The  call  sequence  is  followed  by  Tel.  #1, Tel.  #2,  Tel.  #3  to  Tel.  #4.  It  is recommended  to  set  digital  reporting method in first priority for immediate help.   If either Digital Alarm reporting OR Speech Alarm  reporting  is  set,  with  anyone answered  successfully,  the  call  sequence will be terminated automatically.   If both Digital and Speech Alarm reporting are  set,  the  reporting  call  sequence  will only  be  terminated  once  one  Digital reporting (any of CID, Scancom or Tunstall protocols)  and  one  Speech  reporting  are answered successfully.   There is a calling pause between each call. For  different  Tel.  Numbers,  the  pause  is set as 5 sec, and for same Tel. Number, it is set as 62 sec.  Retry Method  Retry  Cycle:  Each  Tel.  Phone  number can  be  retried  up  to  5  times  alternative; and  max.  15  calls  will  be  retried.  During the retry period, the Red LED still stays on steadily,  while  the  Red  Help  Button backlight dims.   In  the  retry  cycle,  if  any  digital,  voice message,  or  speech  reporting  fails,  CTC-1041RV  makes  a  10-min  pause,  then starts another 15-call retry cycle, followed by  another  10-min  pause.  This  cycle repeats until  all  reporting  is/are answered successfully.   During  the  10-min  pause,  CTC-1041RV returns to normal mode with Red LED on:    Press  the  Green  RESET  button  to terminate the reporting.   If  new  event  happens,  CTC-1041RV starts the reporting immediately.   If an alarm is triggered by Talking Pendant (WTRVS) or CTC-808RV:   For  Tel  number(s)  set  as  Digital Method  (set  by  Commands  20-24), WTRVS  or  CTC-808RV  will  wait  for Central  Monitoring  Station’s  DTMF command  after  digital  reporting  is completed.   For  Tel  number(s)  set  as  Speech Method  (set  by  Commands  20-24), WTRVS  or  CTC-808RV  will  open two-way voice communication.  4.3. Walk Test (Range Test) Put  CTC-1041RV  in  Learning  Mode  to
                                                                                                                                     28determine the operation range of the devices. Step 1.  From  Idle  mode,  press  and  hold  the RESET button for 6 seconds. <<NNOOTTEE>>   Once  pressed,  a  button  beep  sound will  be  heard.  CTC-1041RV  will  emit one  short  beep  at  3  sec.,  then  a double beep when it reaches 6 sec. Step 2.  Release the button after you heard the double  beep. Then, a short beep will be  heard  indicating  CTC-1041RV  is now  in  Learning  Mode.  The  RED LED begins to flash. Step 3.  Move  the  device  to  your  desirable location  in  the  house,  and  press  the TEST  button  or  Pendant  button (WTRB)  to  observe  the  range  for  its operation. Step 4.  If  CTC-1041RV  responds  with  one long  beep, then the particular device is within the operation range. <<NNOOTTEE>>  For  Talking  Pendant  WTRVS:  During Walk  Test,  when  the  Pendant  button  is pressed  you  will  hear  WTRVS  emit  beep (1s-on  /  1s-off).  After  about  3  sec,  the Control Panel will emit a long beep. About 2  sec  later,  the  Control  Panel  will  emit  a long beep again, indicating the Pendant is within  the  operating  range.  If  you  do  not hear  beeps emitted  by Control  panel, turn the  Pedant  off  and  repeat  the  steps mentioned above until  you  hear the Panel beeps. Step 5.  To  exit  Learning  Mode,  press  both RESET  &  HELP  buttons simultaneously.     Or,  CTC-1041RV  will  exit  Learning mode  automatically  after  5  mins  of inactivity.   4.4. Global Test  Global Test is used to  test  if the complete system is working properly.    To do the Global Test: Step 1.  Press the RESET button once. Step 2.  Within  5  sec,  press  Pendant button.  Step 3.  CTC-1041RV  will  emit  a  short beep  and  report  to  Monitoring Center. <<NNOOTTEE>>   This  function  is  for  WTR  only,  not  for WTRVS.  4.5. Factory Reset CTC-1041RV  will  clear  all  programmed parameters by the following sequence: Step  1.  Unplug  the  power  cord  from  the  DC Jack. Step 2.  Remove  the  Battery  Switch  rubber cap. Step 3.  Use a pen or screw-driver to slide the Battery Switch to OFF position (or the opposite direction of the ON marking) Step 4.  Plug the power cord into the DC jack while holding  down both the  HELP & RESET buttons,  until one long  beep is  heard,  indicating  that  the  Factory Reset is successful.  Step 6.  Release both buttons Step 7.  Slide  the  Battery  Switch  back  to  ON position again. Step 8.  Replace  the  Battery  Switch  rubber cap. <<NNOOTTEE>>   Once  the  Fatory  Reset  is  executed, all the programmed data is returned to its  default  value  and  all  the  devices that have been learnt-in are removed.  You  will  have  to  do  the  programming and  learn-in  the  devices  one-by-one again.
                                                                                                                                     295. Appendix 5.1. CID Event code  100 - Panel emergency  When  the  red  HELP  Panel  button  is pressed.  101 - Personal emergency  When  Wrist  Transmitter/Emergency Pendant (WTR), Fall Sensor, WTRVS, PCU3  or  CTC-808RV  RED  Button  is pressed.  102 –Inactivity   If  no  sudden  movement  within  10 seconds  after  fall  detection,  an inactivity  code  will  be  sent  to  Central Monitoring Station.    110 - Smoke emergency   When  the  Smoke  Detector  (SD)  is triggered.   120 - Fall emergency  When a fall sensor is triggered.  147 - Sensor Supervisory Failure  When  CTC-1041RV  is  unable  to receive  the  supervisory  signal transmitted from the Wrist Transmitter /  Emergency  Pendant  (WTR)  for  a pre-set  period  by  Command  #49, Green LED flashes every 2 sec.  154 - Water emergency   When Water Sensor (WS) is triggered  162 - Carbon Monoxide emergency   When  Carbon  Monoxide  Detector (CO) is triggered  301 - Panel AC Failure  When AC power fails for more than 10 sec,  Green  LED  flashes  every  sec with a beep every 30 sec.  302 - Panel Low battery  When  CTC-1041RV  is  under  Low Battery  status,  Green  LED  flashes every 2 sec with 2 beeps every hour.  311 - Panel Battery Not Connected   When  CTC-1041RV  is  under  Battery Not  Connected  status,  Green  LED flashes  every  2  sec  with  2  beeps every hour.  373 - Smoke Low battery  When  Smoke  Detector  is  under  Low Battery  Status,  Green  LED  flashes every 2 sec with 3 beeps every hour.  380 - WTR Low Battery  When  Wrist  Transmitter  (WTR)  or Emergency  Pendant  is  under  Low Battery  Status,  Green  LED  flashes every 2 sec with 3 beeps every hour.  384 - Other devices Low Battery  When  other  devices  (except  SD  and WTR)  are  under  Low  Battery  Status, Green LED flashes every 2 sec with 3 beeps every hour.  602 - Periodic test report  When  CTC-1041RV  reports  periodic test call to monitoring Center.  606 - Follow-On Function  When  CTC-1041RV  receives  kiss-off from  Monitoring  Center  for  opening Speech channel.    611 - Global test   When  CTC-1041RV  reports  Global Test to Monitoring Center.  641 - Mobility  When  CTC-1041RV  makes  Mobility Timer Expired reporting. <<NNOOTTEE>>   This  event  code  will  be  sent  with  a fixed zone number of 071  661  –  Nurse  arrived/nurse  finished  his work   When  the  nurse  arrives  within  the preset  time  and  presses  the  green reset  button.  In  this  case  the  event code will be sent with the prefix “1”.  When the nurse finishes treatment for the  caller  and  presses  the  green reset  button  again.  In  this  case  the event code will be sent with the prefix “3”.  If  the  nurse  has  pressed  the  green reset  button  once  in  help  arrived mode  but  did  not  press  the  green reset  button  again  within  the  preset time to end help arrived mode, CTC-1041RV  will  send  this  event  code with  the  prefix  “1”  every  15  minutes
                                                                                                                                     30for four times.   662 – Nurse needs help    When the nurse needs more help and presses the red help button to call for assistance.   663 – Helped arrived mode canceled   When  the  green  reset  button  is pressed twice in help arrived mode to cancel help arrived mode.    When  help  arrived  mode  is  canceled because  two-way  communication established in  the  help arrived  mode is terminated by pressing DTMF 9.  5.2. Tunstall Event code  D#1011 - Panel AC Restored  When  AC  power  is  restored  to  CTC-1041RV.  D#1012 - Global test & Periodic test call report  When  CTC-1041RV  reports  Global Test to monitoring Center.  When  CTC-1041RV  reports  periodic test call to monitoring Center.  D#1013 - Sensor Supervisory Failure  When  CTC-1041RV  is  unable  to receive the signal transmitted from the Wrist  Transmitter  /  Emergency Pendant (WTR) for a pre-set period by Command #49.  D#1014 - Device Low Battery  When  devices  are  under  Low  Battery Status,  Green  LED  flashes  every  2 sec with 3 beeps every hour.  D#1015 – Mobility/ Inactivity   When  CTC-1041RV  makes  Mobility Timer Expired reporting.  If  no  sudden  movement  within  10 seconds  after  fall  detection,  an inactivity  code  will  be  sent  to  Central Monitoring Station.    D#1016  -  Personal  emergency/fall emergency   When  Wrist  Transmitter/Emergency Pendant (WTR), Fall Sensor, WTRVS, PCU3 or CTC-808RV is pressed.  When a fall sensor is triggered.   D#1017 - Panel emergency  When the RED HELP Panel button is pressed.  When Water sensor is triggered.  D#1018 - Smoke emergency  When  Smoke  Detector  (SD)  is triggered.  When Carbon Monoxide Detector (CO) is triggered.  D#1019 - Panel AC Failure  When AC power fails for more than 10 sec,  Green  LED  flashes  every  sec with a beep every 30 sec.  D#1019  –  Panel  Low  Battery  or  Battery Not Connected  When  CTC-1041RV  is  under  Low Battery  or  battery  Not  Connected status, Green LED flashes every 2 sec with 2 beeps every hour.  5.3. Scancom Event code  515555517 - Panel emergency / Pendant 1  emergency  /  WS  emergency  /  Fall emergency / WTR / PB emergency  When  the  Red  HELP  Panel  button  is pressed.  When  Pendant  1  is  pressed  or triggered.  When Water Sensor is triggered  When  Fall  Sensor  is  triggered  or pressed.   When  WTR  (non  Pendant  1  or Pendant 2) or PB is pressed.  555155517 - Pendant 2 emergency  When Pendant 2 is pressed.  515555518  –  Pendant  1  Emergency (Low Battery)  When  Pendant  1  is  pressed  or triggered under Low Battery status.  555155518  –    Pendant  2  Emergency (Low Battery)  When  Pendant  2  is  pressed  or triggered under Low Battery status.  515155557  -  Pendant  1  /  Panel    Button emergency and Pendant 2 emergency
                                                                                                                                     31 When  Pendant  1  and  Pendant  2 buttons are pressed together.  When  the  Red  Help  Button  and Pendant 2 button are pressed together.  515555157 – Help arrived mode   When help arrived mode is activated.   551555517 – Mobility/Inactivity   When  CTC-1041RV  makes  Mobility Timer Expired reporting.   If  no  sudden  movement  within  10 seconds  after  fall  detection,  an inactivity  code  will  be  sent  to  Central Monitoring Station.  555556558 - Panel Low battery / Battery Not Connected  When  CTC-1041RV  is  under  Low Battery  or  Battery  Not  Connected status, the Green LED flashes every 2 sec with 2 short beeps every hour.  555551557 - AC Failure  When  the  AC  power  fails  for  more than  10  sec,  the  Green  LED  flashes every sec with a beep every 30 sec.  555553557 -  AC Failure  Restore  /  Panel Low  Battery  restore  /  Battery  Not Connected restore  When  the  AC  power  failure  status  is restored. .  When the Panel Low Battery status is restored  When  the  Panel  Battery  Not Connected status is restored.  515555559  -  Global  test  /  WTR Supervision Failure  When  CTC-1041RV  reports  Global Test to monitoring Center.  When  CTC-1041RV  is  unable  to receive the signal transmitted from the Wrist  Transmitter  for  a  pre-set  period by Command #49.  555555559  -  Periodic  test  report  /  Help Arrived  When  CTC-1041RV  reports  Periodic test call to Monitoring Center.  When  CTC-1041RV  makes  Help Arrived reporting.  535555557  -  WTR  Supervision  Failure Restore / WS Emergency Restore  When  the  WTR  supervision  failure status is restored.  When  WS  emergency  status  is restored.  555555558 - Device Low Battery  When  devices  are  under  Low  Battery Status, the Green LED flashes every 2 sec with 3 beeps every hour.  555555558 - Device Low Battery Restore  When  the  device  Low  Battery  status, is restored.  155555517 - SD or CO emergency  When  the  Smoke  Detector  (SD)  or Carbon  Monoxide  Detector  (CO)  is triggered.  355555517  -  SD  or  CO  emergency restore  When  the  Smoke  Detector  (SD)  or Carbon  Monoxide  Detector  (CO) emergency status is restored.                 FCC Statement  This  device  complies  with  Part  15  of  the  FCC Rules.  Operation  is  subject  to  the  following  two conditions: (1) This device may not cause harmful interference, and (2)  This  device  must  accept  any  interference received,  including  interference  that  may  cause undesired operation.
                                                                                                                                     325.4. CTC-1041RV Programming Command Table  DTMF CHARACTER COMMANDS DTMF ACK COMMAND OPERATION  TERMI- NATOR DTMF ACK DEFAULT 01#  Bi  Telephone number 1  #  Bi No number 02#  Bi  Telephone number 2  #  Bi No number 03#  Bi  Telephone number 3  #  Bi No number 04#  Bi  Telephone number 4  #  Bi No number 05#  Bi Telephone number for alarm report  #  Bi 1,2,3,4 06#  Bi Telephone number for status report  #  Bi 1,2,3,4 07#  Bi  Telephone number for Non-Emergency Call  #  Bi  Disable 10#  Bi Global account number, 4 to 6 digits  #  Bi No account number 11#  Bi 4-6 digits Account number 1 (Tel. Number 1)  #  Bi No account number 12#  Bi 4-6 digits Account number 2 (Tel. Number 2) #  Bi No account number 13#  Bi 4-6 digits Account number 3 (Tel. Number 3)  #  Bi No account number 14#  Bi 4-6 digits Account number 4 (Tel. Number 4)  #  Bi No account number 20#  Bi All formats the same, 0 = Contact ID,  1= Scancom, 2 = Tunstall, 3 = Voice  #  Bi Contact ID 21#  Bi 0 = Contact ID, 1= Scancom, 2 = Tunstall,  3 = Speech (Tel. Number 1)  #  Bi Contact ID 22#  Bi 0 = Contact ID, 1= Scancom, 2 = Tunstall,  3 = Speech (Tel. Number 2)  #  Bi Contact ID 23#  Bi 0 = Contact ID, 1= Scancom, 2 = Tunstall,  3 = Speech (Tel. Number 3)  #  Bi Contact ID 24#  Bi 0 = Contact ID, 1= Scancom, 2 = Tunstall,  3 = Speech (Tel. Number 4)  #  Bi Contact ID 31#  Bi Ringer enable, 0 = Disable, 1 = Enable  #  Bi Ringer Disabled 32#  Bi Audible fault alert, 0 = Off, 1 = On  #  Bi Off 33#  Bi Help arrived signalling,  0 = Off, 1 = On  #  Bi Help arrived signalling On 34#  Bi Emergency button enable  0 = Button off, 1 = Button on  #  Bi Emergency button On 35#  Bi Silent Mode  0 = Silent mode On, 1 = Silent mode Off  #  Bi Silent mode Off 37#  Bi AC fault report, 0 = Off, 1 = On  #  Bi On 38#  Bi Follow-On & Call Back Function, 0 = Follow-On, 1= Call-Back, 2= Follow-On & Call-Back  #  Bi Follow-On 39#  Bi  Dialling Mode 0 = Tone, 1 = Pulse  #  Bi  Tone 40#  Bi Set Access Code  #  Bi 1111 41#  Bi Auto answer for Remote programming,  00 = None, 01 - 32 = Auto answer 1 - 32 rings #  Bi 20 rings
                                                                                                                                     33DTMF CHARACTER COMMANDS DTMF ACK COMMAND OPERATION  TERMI- NATOR DTMF ACK DEFAULT 43#  Bi Test call, 0 = OFF, 1 = 1 Day, 2 = 2 Days,  3 = 3 Days, 4 = 4 Days. 5 = 5 Days,  6 = 6 Days, 7 = 7 Days, 8 = 30 days #  Bi  No test call 44#  Bi Mobility time  0= Disable, 1=12 Hour, 2=24 Hour   #  Bi Mobility time disable 45#  Bi Follow-On Choice, 0 = Wait command,  1 = Listen, 2 = Two way voice communication #  Bi  Two-way voice communication 46#  Bi Follow-On mode & Two-Way Period,  01=1 min, 02=2mins, 03=3mins, 04=4mins, 05=5mins, 06=6mins, 07=7mins, 08=8mins, 09=9mins, 10=10mins. #  Bi  2 minutes 47#  Bi Off-set time, 1=1 hour, 2=2 hours, 3=3 hours,  4=4 hours, 5=8hours, 6=12 hours  #  Bi  1 Hour 49#  Bi Supervision 0 = disable, 1 = 4 days, 2 = 5 days, 3 = 6 days, 4 = 7 days, 5 = 8 days, 6 = 9 days, 7 = 10 days, 8 = 30 days #  Bi  Disable 66#  Bi  Guard  time  delay  for  Fall  Sensor,  00  =  Instant reporting; … 99 = 99 seconds   #  Bi  15 sec 67#  Bi  Help Arrived Timer 01-15 = 1-15 minutes  #  Bi  15 minutes 75#  Bi  Help Not Arrived Call  #  Bi No number 80#  Bi Remove all device (learnt in Command 91-94) ---  ---  --- 81#  Bi Remove pendant #1 (learnt in Command 91)  ---  ---  --- 82#  Bi Remove pendant #2 (learnt in Command 92)  ---  ---  --- 83#  Bi Remove Silent Pendant  (learnt in Command 93)  ---  ---  --- 84#  Bi Remove the Devices (learnt in Command 94) ---  ---  --- 91#  Bi Learn-in pendant #1  ---  Bi Bi No device 92#  Bi Learn-in pendant #2  ---  Bi Bi No device 93#  Bi Learns-in silent emergency transmitters  ---  Bi Bi No devices 94#  Bi Learn-in smoke detectors, CO detectors, pendants and fixed emergency transmitters, long range pendants ---  Bi Bi No device 98#  Bi Load defaults when   is pressed (DTMF A is heard after defaults have been loaded)  #  Bi  --- 99#  Bi Exit programming mode      ---
                                                                                                                                     34FCC statements  Changes  or  modifications  to  the  equipment  not  expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  This  device  complies  with  FCC  RF  radiation  exposure limits set forth for an uncontrolled environment. The antenna  used  for  this  transmitter  must  be  installed  to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.  NOTE:  This  equipment  has  been  tested  and  found  to comply with the limits for a Class B digital device, pursuant to Part 15 of  the  FCC  Rules.  These  limits  are  designed  to  provide reasonable  protection  against  harmful  interference  in  a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance  with  the  instructions,  may  cause  harmful interference to radio communications. However, there is no guarantee  that  interference  will  not  occur  in  a  particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment  off  and  on,  the  user  is  encouraged  to  try  to correct  the  interference  by  one  or  more  of  the  following measures: -- Reorient or relocate the receiving antenna. --  Increase  the  separation  between  the  equipment  and receiver. --  Connect  the  equipment  into  an  outlet  on  a  circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.  This device  complies with Industry  Canada licence-exempt RSS standard(s). Operation is subject to  the  following  two  conditions:  (1)  this  device  may  not cause interference, and (2) this device must  accept  any  interference,  including  interference  that may cause undesired operation of the device.  Le  présent  appareil  est  conforme  aux  CNR  d'Industrie Canada applicables aux appareils radio exempts  de  licence.  L'exploitation  est  autorisée  aux  deux conditions suivantes : (1) l'appareil ne doit  pas  produire  de  brouillage,  et  (2)  l'utilisateur  de l'appareil doit accepter tout brouillage radioélectrique  subi,  même  si  le  brouillage  est  susceptible d'en compromettre le fonctionnement.