Clamp Meter (CLMT-1ZW) CL-Meter-ZW is a Z-Wave Clamp Meter aim to monitor  and  report the  total  amount  of electricity uses in  your facility by connecting the clamp onto the power cable. The Energy Meter is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave  is  a  wireless  communication  protocol  that  uses  a  low-power  RF  radio.  By  taking  advantage  of  the Z-Wave  mesh  network,  commands  can  be  routed  to  their  destination  via  intermediary  “listening”  Z-Wave products.  Parts Identification 1.  Red LED Flashes once: When Clamp Meter is transmitting a signal. Flash Twice: The Clamp Meter has successfully joined a Z-Wave network. 2.  AC Input cable 3.  Current Transformer Cable (CT1) 4.  Current Transformer Cable (CT2) 5.  Function Button -Press the button once to report the value of the meter to the Z-Wave network. -Press the button 3 times within 1.5 seconds to transmit a learn code. -Press and hold the button for 10 seconds to factory reset the Clamp Meter. 6.  Reserved 7.  Mounting Hole 8.  Mounting Hooks 9.  Mounting Bracket       Installation  Wiring
WARNING Wiring of the device should only be performed by a licensed electrician. The circuit box’s main breaker should be turned off to perform installation.     The insertion hole wire specification is AWG18 or Ø 1.02 (mm²).   The Clamp specification is 60A Ø10mm   Please make sure the main power in your facility is also off before installing. Follow the steps below: 1. Connect AC Input cable to a socket near the Electrical Box to power on the Clamp Meter. 2. Attach both ends of the Current Transformer Cables first as picture shown below. Once you have attached the Current Transformer Cable, start spinning the waterproof latch clock-wise until you have tighten and secure both ends of the Current Transformer Cable.            3. Open the clamp  as indicated  by below picture. The clamp  should be applied  onto an  electic cable  The arrow direction on the clamp need to point at the correct direction of the electricity current flows (KL). If arrow is faced in reverse direction, the reading will display negative value (-) however it will not influence the readings.                       4. Follow  the  schematics  below  as  an  example;  clip  the  clamps  on  the  electricity  cables  on  the  2  the incoming power cable connected to the Main Circuit Breaker.   Mounting The Clamp Meter has a mounting bracket for mounting purposes. 1. Use the mounting bracket as template to mark the two holes on the wall for installing screws. KL
2. Screw the mounting bracket onto the wall according to marked location. Install wall plugs if necessary. 3. Locate the hooks of the mounting bracket and line up the hooks with the mounting holes on the Clamp Meter. Fit the hooks into the mounting holes as picture below. Installation is now complete.    Adding Device (Inclusion) This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.  Plug in the AC Input cable into the socket to power on the Clamp Meter.  Put  the  Z-Wave  control  panel  into  Inclusion  mode  (please  refer  to  the  Z-Wave  control  panel manual).  Within 1.5 seconds, press the Function Button 3 times.  Refer  to  the  operation  manual  of  the  Z-Wave  Gateway  or  Control  Panel  to  complete  the  adding process.  If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device  is  unable  to  be  added  into  the  current  Z-Wave  Gateway/Control  Panel,  try removing  it  first (see Removing Device).  Removing Device (Exclusion) The device must be removed from existing Z-Wave network before being added into another. Exclusion Mode  Put  the  Z-Wave  Gateway  or  Control  Panel  into  Exclusion  mode  (please  refer  to  the  Z-Wave  or control panel manual).  Within  1.5  seconds,  press  the  Function  Button  3  times  and  the  device  will  be  removed  from  the Z-Wave network. Factory Reset Factory  resetting  the  device  will  restore  it  to  factory  default  settings  (i.e.  not  included  into  any  Z-Wave network).  Please  only  use  this  procedure  if  the  Z-Wave  Gateway  or  Control  Panel  is  lost  or  otherwise inoperable.  Press and hold the Function Button of the device for 10 seconds to factory reset.  Range Test To test whether the device is able to communicate with the Z-Wave Gateway or Control Panel:  Put the Gateway / Control Panel into range test mode (Walk Test).  Press the Function Button on the device.  The Gateway / Control Panel should display if the device is within the operation range (please refer to the operation manual of the Gateway / Control Panel).  Z-Wave Sleep Mode  The  Clamp Meter  will  enter  Z-Wave  Sleep  mode  (to conserve  power)  after  waking  up  for a  short period of time (~10 seconds). While in Z-Wave sleep mode, Z-Wave Gateways or Control Panels are unable to send commands to the Clamp Meter.  To program the Clamp Meter using the Z-Wave Gateway/Control Panel, please send command(s) to the Clamp Meter within the wake-up period.      Energy Consumption Monitor     The Clamp Meter will transmit a signal from the clamp itself with its power consumption data every 10 minutes to the Z-Wave network coordinator.
  Reading from clamp on Current Transformer Cable CT-1 is reported to Meter Channel 1   Reading from clamp on Current Transformer Cable CT-2 is reported to Meter Channel 2.   Whenever the Clamp’s energy output changes by +/- 2W, the Clamp Meter will automatically transmit a signal with power consumption data to the Z-Wave network coordinator for update.   The  Clamp  Meter  transmits  a  signal  with  power  data  to  coordinator  whenever  accumulated  power usage of the clamp increases by 0.1kW/hr.   The Clamp has an accuracy of +/- 5%.   To clear the clamp of its accumulated power consumption data, follow steps below: 1.  Un-plug AC cable to power down Clamp Meter. 2.  Press  and  hold  the  function  button,  while  holding  the  button,  power  on  the  Clamp  Meter  by re-plug in the AC cable. 3.  Release the function button when red LED starts to quickly flash. 4.  Un-plug and re-plug AC cable again, clearing is complete.   Maximum Operation Load   110V: 6600W and 60A   230V: 13800W and 60A.    Z-Wave Information Device Type: Whole Home Meter - Simple Role Type: Always On Slave (AOS) Command Class Support/Control Mandatory CC Support:              Association CC, v2                                                        Association Group Information CC                                                       Device Reset Locally CC                                                       Manufacturer Specific CC, v2                                                       Meter CC,                                                       Version CC, v2                                                       Z-Wave Plus Info CC, v2                                                       Power Level CC,                                                       Firmware Update CC, v2   Z-Wave’s Groups (Association Command Class Version 2)   Group 1 for “LifeLine”:   Device Reset Locally CC             Meter CC
Federal Communication Commission Interference Statement ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneofthefollowingmeasures:.Reorientorrelocatethereceivingantenna..Increasetheseparationbetweentheequipmentandreceiver..Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected..Consultthedealeroranexperiencedradio/TVtechnicianforhelp.FCCCaution:Toassurecontinuedcompliance,anychangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatethisequipment.(Example‐useonlyshieldedinterfacecableswhenconnectingtocomputerorperipheraldevices).ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.