Climax Technology Co LMHTZB Ambient Light, Humidity and Temperature Sensor User Manual LMHT 1ZBS 20160330 FCCx

Climax Technology Co Ltd Ambient Light, Humidity and Temperature Sensor LMHT 1ZBS 20160330 FCCx

Users Manual

 1LMHT-1ZBS    Ambient Light, Humidity and Temperature Sensor    Introduction LMHT-1ZBS is a ZigBee Ambient Light, Humidity and Temperature Sensor. It monitors your home environment and transmits measured Illuminance (lux), humidity and temperature to the coordinator in the ZigBee network. The sensor utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless communication protocol that is reliable, has low power consumption and high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission. The sensor serves as an end device in the ZigBee network. It can be included in the ZigBee network to transmit signal upon activation, but cannot permit any other ZigBee device to join the network through the sensor.    Parts Identification 1.  Light Sensor / LED Indicator -  Flashes once: Factory Reset -  Flashes twice: After the sensor has successfully joined a ZigBee network. -  Flashes 3 times: Battery inserted. -  Flashes 5 times: Low battery detected when inserting battery. -  Flashes once every 20 minutes: The sensor has lost connection to its current ZigBee network. 2. Temperature Sensor 3. Battery Compartment 4. Function Button -  Press once to send a signal to the coordinator. -  Press and hold for 10 seconds to reset the device.  Features  Lighting, Humidity and Temperature Monitoring  The sensor measures illuminance, humidity and temperature to transmit measured data to ZigBee network coordinator regularly.   Illuminance reading is transmitted every 30 minutes. Humidity and temperature reading is transmitted every 10 minutes. The sensor will also transmit signal automatically when:   The temperature changes by +/- 2°C.    Humidity changes +/- 10%.   When the current illuminance changes by +/- 10%.  You can also press the Function Button once to transmit current reading manually.  Battery and Low Battery Detection  The sensor uses one CR123A 3V Lithium battery as its power source.    The sensor features Low Battery Detection function. When the battery voltage is low, the sensor will transmit Low Battery signal to the coordinator in ZigBee network  When changing battery, after removing the old batteries, press the Function Button twice to fully discharge before inserting new battery.  If low battery voltage is detected upon inserting new battery, the LED indicator will flash 5 times.  Supervision The sensor will transmit a supervision signal along with the reading signal to report its condition regularly. The factory default interval is 30 minutes, which can be adjusted according to setting.    ZigBee Network Setup
 2 ZigBee Device Guideline ZigBee is a wireless communication protocol that is reliable and has low power consumption and high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission. Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after powering on. Since performing a task in connecting network may consume some power, it is required to follow the instructions to avoid draining battery of a ZigBee device - Ensure your ZigBee network router or coordinator is powered on before inserting battery into the ZigBee device. - Ensure the ZigBee network router or coordinator is powered on and within range while a ZigBee device is in use. - Do not remove a ZigBee device from the ZigBee network router or coordinator without removing the battery from a ZigBee device.  Joining the ZigBee Network As a ZigBee device, the sensor needs to join a ZigBee network to transmit signal. Please follow the steps below to join the sensor into the ZigBee network. 1. Detach the Top Cover and Base assembly and insert battery. 2. Press and hold the function button for 10 seconds as the sensor resets (LED flashes once) and starts searching for existing ZigBee network. Please make sure the permit-to-join feature on the router or coordinator of your ZigBee network is enabled. 3. If the sensor successfully joins a ZigBee network, the LED Indicator will flash twice to confirm. 4. After joining the ZigBee network, the sensor will be registered in the network automatically. Please check your ZigBee coordinator, system control panel or CIE (Control and Indicating Equipment) to confirm if joining and registration is successful. 5. After joining the ZigBee network, if the sensor loses connection with current ZigBee network, the LED will flash every 20 minutes to indicate. Please check your ZigBee network condition and sensor signal range to correct the situation.  Removing Device from ZigBee Network (Factory Reset) To remove the Power Switch from current ZigBee network, the sensor must be put to Factory Reset to complete device removal. Factory Reset function will clear the device of its stored setting information and prompt the sensor to search for new ZigBee network.   Before removing device, make sure the sensor is within current ZigBee network signal range 1.  Press and hold the function button for 10 seconds, then release the button to reset sensor. 2.  Upon reset, the sensoe will clear current ZigBee network setting and transmit signal to ZigBee coordinator to remove itself from current ZigBee network. It will then actively search for available ZigBee network again and join the network automatically.    Installation  Mounting the Sensor The sensor can be mounted using two methods: Self-adhesive or Screw mounting. Self adhesive mounting 1. Clean the surface with a suitable degreaser. 2. Remove the protective covering from one side of double-sided adhesive pad and firmly apply to the back of the device. 3. Remove the other covering and firmly place/press the device in the desired location. Do not use the Self-adhesive mounting method on poorly painted and/or rough surfaces. Screw Mounting The base of the sensor has two screw knockouts, where the plastic is thinner for mounting purposes. To mount the sensor: 1. Detach the Top Cover and Base assembly by loosening the Cover-Fixing Screw using a Philips screwdriver. 2. Break through the knockouts on the base. 3. Use the holes as a template to drill two holes and insert the wall plugs. 4. Screw the base into the wall plugs. 5. Replace the top cover over the base by hooking the base onto the fixing hook and pushing the cover towards the base. 6. Secure and screw the top cover back on to its base using a Philips screwdriver.  Using the Sensor with ZigBee Router IMPORTANT NOTE If the sensor installation location is away from your system control panel and requires ZigBee routers to improve
 3signal strength. DO NOT use a ZigBee Router without backup battery. A ZigBee router without battery will be powered down during AC power failure and the sensor connected to the router will lose connection with ZigBee network. You should plan your sensor installation location using only ZigBee router with backup battery.  Appendix (The Appendix information is for developers only.)  Light Sensor Cluster ID Device ID: Room Sensor 0x0302 Endpoint: 0x01 Server Side  Client Side Mandatory Basic (0x0000)  Basic (0x0000) Identify(0x0003)  Identify(0x0003) Illuminance Measurement (0x0400)   Optional Power Configuration(0x0001) None Temperature Measurement(0x0402)  Relative Humidity Measurement(0x0405)   Attribute of Basic Cluster Information Identifier Name  Type  Range Access Default Mandatory / Optional0x0000  ZCLVersion  Unsigned 8-bit integer  0x00 –0xff  Read only  0x01 M 0x0001 ApplicationVersion Unsigned 8-bit integer  0x00 –0xff  Read only  0x00 O 0x0003  HWVersion  Unsigned 8-bit integer  0x00 –0xff  Read only  0 O 0x0004  ManufacturerName  Character String  0 – 32 bytes  Read only  Climax Technology  O 0x0005  ModelIdentifier  Character String  0 – 32 bytes  Read only  (Model Version)  O  0x0006  DateCode  Character String  0 – 16 bytes  Read only   O 0x0007  PowerSource  8-bit 0x00 –0xff Read only   M 0x0010  LocationDescription  Character String  0 – 32 bytes  Read / Write   O 0x0011  PhysicalEnvironment  8-bit 0x00 –0xff Read / Write  0x00 O 0x0012  DeviceEnabled  Boolean 0x00 –0x01 Read / Write  0x01 M  Attribute of Identify Cluster Information Identifier Name  Type  Range Access Default Mandatory / Optional0x0000  IdentifyTime  Unsigned 16-bit integer 0x00 –0xffff  Read / Write  0x0000 M  Attribute of Power Configuration Cluster Information Identifier Name  Type  Range Access Default Mandatory / Optional0x0035  BatteryAlarmMask  8-bit bitmap  0000 000x  Read / Write  0000 0000  O  Attribute of Illuminance Measurement Cluster Information   Identifier Name  Type  Range Access Default Mandatory / Optional
 40x0000  MeasuredValue Signed 16-bit Integer MinMeasuredValueto MaxMeasuredValueRead only  0x00 M 0x0001  MinMeasuredValue Signed 16-bit Integer  0x0002 – 0xfffd  Read only  - M 0x0002  MaxMeasuredValue Signed 16-bit Integer  0x0001 – 0xfffe  Read only  - M  Attribute of Temperature Measurement Cluster Information Identifier  Name Type Range Access Default Mandatory / Optional0x0000 MeasuredValue Signed 16-bit Integer MinMeasuredValueto MaxMeasuredValueRead only  0x00 M 0x0001 MinMeasuredValue Signed 16-bit Integer  0x954d – 0x7ffe  Read only  -1000 (-10℃)  M 0x0002 MaxMeasuredValue Signed 16-bit Integer  0x954e – 0x7fff  Read only  5000 (50℃)  M 0x0003 Tolerance Unsigned 16-bit Integer  0x0000 – 0x0800  Read only  100 (1℃)  O  Attribute of Relative Humidity Measurement Cluster Information Identifier Name  Type  Range Access Default Mandatory / Optional0x0000 MeasuredValue Unsigned 16-bit Integer MinMeasuredValue to MaxMeasuredValueRead only   M 0x0001 MinMeasuredValue Unsigned 16-bit Integer  0x0000 – 0x270f  Read only  0 (0%)  M 0x0002 MaxMeasuredValue Unsigned 16-bit Integer  0x0001 – 0x2710  Read only  10000 (100%)  M 0x0003 Tolerance Unsigned 16-bit Integer  0x0000 – 0x0800  Read only  200 (2%)  O
 5Federal Communication Commission Interference Statement  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help. FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices).  FCC Radiation Exposure Statement  This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.  This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and   (2) This device must accept any interference received, including interference that may cause undesired operation.