Climax Technology Co MZ Wireless Smart Home Alarm Panel User Manual MZ 1 8 20130812

Climax Technology Co Ltd Wireless Smart Home Alarm Panel MZ 1 8 20130812

Users Manual

Table of  ContentsTable of  ContentsTable of  ContentsTable of  Contents     1. INTRODUCTION  _____________________________________________________________________ 1 2. APPLICATION OVERVIEW _____________________________________________________________ 2 2.1. IDENTIFYING THE PARTS:  _____________________________________________________________ 2 2.2. THE POWER SUPPLY: ________________________________________________________________ 4 2.3. SYSTEM REQUIREMENTS:_____________________________________________________________ 5 3. GETTING STARTED  __________________________________________________________________ 6 3.1. HARDWARE INSTALLATION FOR MZ-1/8  __________________________________________________ 6 3.2. SOFTWARE INSTALLATION FOR MZ-1/8 ___________________________________________________ 6 4. CONNECTING TO WEBPAGE  __________________________________________________________ 9 5. SYSTEM SETTINGS  _________________________________________________________________ 11 5.1. USER  __________________________________________________________________________ 11 5.2. REPORT  ________________________________________________________________________ 13 5.3. PANEL __________________________________________________________________________ 16 5.4. AREA  __________________________________________________________________________ 18 5.5. NETWORK _______________________________________________________________________ 20 5.6. UPLOAD  ________________________________________________________________________ 22 6. DEVICE MANAGEMENT ______________________________________________________________ 23 6.1. LEARNING _______________________________________________________________________ 23 6.2. ADD DEVICE  _____________________________________________________________________ 26 6.3. WALK TEST ______________________________________________________________________ 27 6.4. EDIT DEVICE _____________________________________________________________________ 28 6.5. DELETE DEVICE ___________________________________________________________________ 31 6.6. REQUEST MEDIA __________________________________________________________________ 31 6.7. POWER SWITCH CONTROL ___________________________________________________________ 32 6.8. SIREN LEARNING/CONTROL __________________________________________________________ 32 7. CAPTURED EVENTS  ________________________________________________________________ 33 8. HISTORY RECORDS _________________________________________________________________ 35 8.1. HISTORY ________________________________________________________________________ 35 8.2. REPORTED EVENT _________________________________________________________________ 36 9. PANEL CONTROL ___________________________________________________________________ 37 10. HOME AUTOMATION  _______________________________________________________________ 38 11. FIRMWARE  _______________________________________________________________________ 39
 12. ALARM ACTIVATION TABLE _________________________________________________________ 39 13. VESTA EZ HOME APPLICATION ______________________________________  !  13.1. FOR IPHONE ____________________________________________________  !  13.2. FOR ANDROID PHONE _____________________________________________  !  14. EVENT CODE  _____________________________________________________________________ 42 1. Introduction This  manual  covers  the  installation,  programming,  and  control  of  IP  based  MZ-1  and  MZ-8 control panels. Both MZ-1 and MZ-8 supports full range IP reporting capability with webpage for setting configuration and system control, MZ-8 also has the extra function of reporting through RF. The advanced IP Security System with fully integrated TCP/IP technology and Ethernet connectivity is able to take full advantage of new advances in IP Home Security and Home Automation and multi-path signalling.   Remote control of the panel is achieved by registering the panel in our Home Portal Server. With Home Portal Server, you can connect to your panel anytime, anywhere in the world through internet connection either with a computer or a smartphone using our Vesta Home application. Please refer to our Home Portal User Guide for detail about registering and using Home Portal Server. Remote  programming  and  command  is  also  available  for  MZ-8  to  configure  your  panel  by messages.  You  can  also  use  our  Vesta  EZ  Home  smartphone  applications  to  send  the commands easily for basic panel functions.
 2 2. Application Overview 2.1. Identifying the parts: Case A  1. Panel Status LED (Dual Colour - Red & Green) RED LED ON - System in Arm Mode. RED LED FLASHES - System in Home 1/2/3 Mode. GREEN LED ON - System in Disarm Mode. GREEN LED FLASHES - System in Learn Mode. LED OFF - System in Walk Test Mode  2. Alarm & Fault Status LED (Dual Colour - Red & Yellow) (with display priority) RED LED FLASHES - System is currently alarming. RED LED ON - Alarm memory in system. YELLOW LED FLASHES - AC Power failure.   YELLOW LED ON – Other fault condition (not including AC Power Failure ). LED OFF – System normal. LED Flashing Sequence Alarm Alarm Memory Panel AC failure Other Fault
 3 3. Operational Status LED (Dual Colour - Yellow & Red) (with display priority) YELLOW LED ON - Network error   LED OFF – Network ok LED Flashing Sequence: Network ok Network error 4. Buzzer 5. Ethernet Port 6. Learn / Reset Button   7. Empty Port   8. DC Jack For connecting the DC 12V, 1A switching power. 9. Battery Switch 10. Tamper Switch   11. Wall Mounting Bracket   Case B  1. Panel Status LED (Dual Colour - Red & Green) RED LED ON - System in Arm Mode. RED LED FLASHES - System in Home 1/2/3 Mode. GREEN LED ON - System in Disarm Mode. GREEN LED FLASHES - System in Learn Mode. LED OFF - System in Walk Test Mode 2. Alarm & Fault Status LED (Dual Colour - Red & Yellow) (with display priority) RED LED FLASHES - System is currently alarming. RED LED ON - Alarm memory in system. YELLOW LED FLASHES - AC Power failure.
 4 YELLOW LED ON – Other fault condition (not including AC Power Failure ). LED OFF – System normal. LED Flashing Sequence Alarm Alarm Memory Panel AC failure Other Fault 3. Operational Status LED (Dual Colour - Yellow & Red) (with display priority) YELLOW LED ON - Network error   LED OFF – Network ok LED Flashing Sequence: Network ok Network error 4. Standing Base 5. Internal Buzzer 6. Ethernet Port   7. Learn/Reset Button   8. Base   9. DC Jack For connecting the DC 12V, 1A switching power. 10. Battery Switch 2.2. The Power Supply: An AC power adapter is required to connect to a wall outlet. Be sure only to use an adapter with the appropriate AC voltage rating to prevent component damage. DC 12V 1A switching power output adaptor is generally used to power the Control Panel for standard version.    Rechargeable Battery  In addition to the adapter, there is a rechargeable battery inside the Control Panel, which serves as a back up in case of a power failure.  During  normal  operation,  the  AC  power  adapter  is  used  to  supply  power  to  the  Control Panel and at the same time recharge the battery. It takes approximately 72 hours to fully charge the battery.   <<NNOOTTEE>>    If the AC power is missing and the battery is near exhaustion, a low battery message will be displayed and the internal siren will be disabled to conserve power.
 5 2.3. System Requirements: The system requires a TCP/IP network environment for MZ-1/8 IP Panel to be included in your network. To install the CD Wizard, your computer must have:   Microsoft Windows 98, ME, NT4.0, 2000, XP, Vista, 7 or 8 operating system.     Microsoft Internet Explorer 5.x, or later and Mozilla Firefox 1.0 compatible.   CD-ROM drive   CPU: Intel Pentium II 266MHz or above   Memory: 32MB (64MB recommended)   VGA resolution: 800x600 or above
 6 3. Getting Started Read this section of the manual to learn how to set up your MZ-1/8 Panel and program System Settings over the Web page.    3.1. Hardware Installation for MZ-1/8 Step 1.  Connect the Power Adaptor to a Wall Outlet and the other end to MZ-1/8. MZ-1/8 will emit one short beep and Panel Status GREEN LED will turn ON.   Step 2.  Connect the Ethernet cable as described below:     Step 2A:    Plug-in the ethernet cable into the Internet jack on the Control Panel.   Step 2B:    Plug-in the other end of the enclosed Internet cable into your Net Router port.   Step 2C:    Once the Internet Set-up is successful, please leave the cable connected. Step 3.  Hardware installation for MZ-1/8 is now complete.  3.2. Software Installation for MZ-1/8   THIS INSTALLATION IS ONLY REQUIRED FOR FIRST TIME USER   1.  RUNNING THE MZ-1/8 FINDER To install the “Finder” software” Step 1.  Insert the supplied CD-ROM into your CD-ROM drive Step 2.  Find the Finder software in the CD-ROM       Step 3.  Double click on the Finder to initiate the installation.     Step 5.  Click  “Change” to select the  file folder,  if  no change  is  required;  click “Next” to  get ready for the installation process.
 7 Step 6.  Click “Next” to begin the Installation. Once the installation is completed, click “Finish” to confirm.   Step 7.  A new icon will be displayed on your desktop.   Step 8.  Double click on the “Finder.exe” to start the installation. The following screen will be displayed:   Step 9.  Click  on “Search”,  It will  start  searching  for recognized  IP  address  within the  Local Network Service. Step 10.  You will be able to locate the current MZ-1/8 IP address among the list.   Displayed with MAC Address and Product version.  Step 11.  Once MZ-1/8 is identified, select MZ-1/8 and click on “Open Web Page” to link to the IP Security System Web page.   Step 12.  Software installation for MZ-1/8 IP Panel is now completed.
 8 2.  CONFIGURE SETTING The Configure setting is for you to setup the network setting manually.   Step 1. Click on Configure Setting, the following window will display:  Step 2. Enter the network information and MZ-1/8’s web user name and password.   (Default) User Name: admin (Default) Password: admin1234 Step 3. Click on OK to confirm. When the username and password are correct, a window will display: Status: Configure success!!
 9 4. Connecting to Webpage Step 1.  Select  MZ-1/8  in  the  Finder  software  and  click  on  “Open  Webpage”  to  connect  to MZ-1/8 webpage. Alternatively, enter MZ-1/8 IP address displayed in Finder into your browser’s address section and click “GO”.  Step 2.  Enter the User name & Password.    Step 3.  Enter the User name & Password and then press “OK”. User Name: admin    Password: admin1234
 10 Step 4.  You will enter the Control Panel webpage, the current Control Panel information will be displayed.
 11 5. SYSTEM SETTINGS 5.1. User     User Code   The User Codes are used for users to acess the alarm system. A total of 10 4-digit User Codes  can  be  stored  in  MZ-1/8.  Each  individual  User  can  be  given  a  name  for  easy recognition when viewing system events.     User PIN code #1 is activated with “1234” as factory default. User PIN code #2~#10 are deactivated by factory default <<NNOOTTEE>>    When entering User PIN Codes with a Remote Keypad, if the wrong PIN Codes were entered 5 times in 10 minutes,  the Control Panel will prohibit further User PIN Code entry for 15 minutes. All User PIN Codes entered during the 15 minute period will result in error for the Remote Keypad.  Guard Code The Guard Code is designed for security personnel to arm/disarm the system. When this code is used for accessing the system, the Control Panel will record the event separately from the User Codes.   The Guard Code consists of 4 digits and is not activated as default by the factory.  Master Code This function is currently disabled Factory default: 1111.
 12  Temporary Code The Temporary Code is used to access the system for a temporary user and is valid only once  per  arming  and  once  per  disarming.    Afterwards,  the  Temporary  Code  is automatically erased and needs to be reset for a new Temporary user. The Temporary Code consists of 4 digits and is not activated as default by the factory.    Duress Code The Duress Code is used to access the system in duress situation. When this code is used for  accessing the system, the Control Panel will report a  secret alarm message without sounding the siren to the Central Monitoring Station to indicate of a “Duress Situation in Progress”. The Duress Code consists of 4 digits and is not activated by factory default.  Installer Code The  Installer  Code  is  used  for  the  installer  to  access  the  Control  Panel  via  remote command. Factory default: 7982.  Latch Option Whe the option is selected, the Control Panel will report all arming/disarming action by this user.  Latch.   When the the Latch option box is ticked, the Latch option is turned ON.   To edit the Codes on Web Page: Step 1.  Key in your preferred 4-digit code Step 2.  Enter a name for the code (optional) Step 2.  Choose to tick On / Off the Latch Option box. Step 3.  Press “Submit” to confirm the new uploaded details.
 13 5.2. Report   This  page  is  for  you  to  enter  the  report  destination  setting.  MZ-1/8  can  store  up  to  8  report destinations.     Reporting Type:   MZ-1/8 supports 5 reporting types:  IP/RF reporting in CID format:   Reporting destination format: ip://Account@Server IP:Port/CID For Example: ip://6543@59.124.123.22:8765/CID ip://  6543  @59.124.123.23 :8765  /CID Reporting type Account (4-8 digits)  Server IP address   Port number Reporting Format  IP/RF reporting in SIA format:   Reporting destination format: ip://Account@Server IP:Port/SIA For Example: ip://6543@59.124.123.22:8765/SIA ip://  6543  @59.124.123.23 :8765  /SIA Reporting type Account (4-8 digits)  Server IP address   Port number Reporting Format  IP/RF reporting in CSV format:   Reporting destination format: ip://Account@Server IP:Port/CSV For Example: ip://6543@59.124.123.22:8765/SIA ip://  6543  @59.124.123.23 :8765  /CSV Reporting type Account (4-8 digits)  Server IP address   Port number Reporting Format
 14  IP/RF reporting in CSV format with user name and password:   Reporting destination format: ip://Account@Server IP:Port/CSV/User/Password For Example: ip://6543@59.124.123.22:8765/CSV/ABCD/1234 ip://  6543  @59.124.123.23 :8765  /CSV  /ABCD  /1234 Reporting type Account (4-8 digits)  Server IP address   Port number Reporting Format User Name Password  Reporting in format: (MZ-8 only) Reporting destination format://Account@mobile number/CID For Example: //1234@0926064587/CID ://  1234  0926064587  /CID Reporting type Account (4-8 digits)  Mobile Number  Reporting Format  reporting in Text format: (MZ-8 only) Reporting destination format:://mobile number/TEXT For Example: /0926064587/TEXT ://  @0926064587  /TEXT Reporting type  Mobile Number  Reporting Format  Digital reporting in format: (MZ-8 only) Reporting destination format: // Account@Tel number For Example: //1234@0926064587 //  1234  @27940001 Reporting type  Account (4-8 digits)    Telephone Number  Email reporting Reporting destination format: mailto: user@example.com For Example: mailto: sales@climax.com.tw mailto:  sales@climax.com.tw Reporting type  Email Account <<NNOOTTEE>>    Reporting type must be entered in lowercase letters   SMTP setting must be completed first for email reporting to function.
 15  Groups:   You  can  assign  reporting  destinations  to  different  groups,  the  reporting  groups  function according to the following rules:  The reporting priority is based on to group number sequence. From Group 1  Group Group 2  Group 3 ….etc  When more than one reporting destinations are assigned to a group, if a report is sent to one of the detinations successfully, the system will stop reporting to the rest of the reporting destination in the same group and move on to report to the next group.   If the Control Panel fails to send report to the first detination in a group, it will move on to  the  next  reporting  destination.  If  all  reporting  destinations  in  the  group  cannot  be reached, the Control Panel will move on to the next group If the Control Panel fails to report to all reporting groups, it will start reporting from group 1 and continue retrying until one report is made successfully.
 16 5.3. Panel   This page is for you to configure panel settings.     Keyword The Keyword is used for receiving commands from users. When a user sends a command to the  Control  Panel, the  correct  keyword  must be  entered along with a  valid  User  PIN code for the Control Panel to recognize the command. The Keyword is disabled by default. (MZ-8 only)  P-word The P-word is also used for receiving commands from Installers. When an installer sends a command to the Control Panel, the correct P-word must be entered along with Installer code for the Control Panel to recognize the command. The P-word is “PROG” by default. (MZ-8 only)  AC Fail Report This is for you to set the waiting time for the Control Panel to make report after detecting AC failure. Factory default is set to 5 minutes.  Jamming Report This is for you to set whether the Control Panel should detect radio frequency interference and make report when interference is detected. Factory default is set to On. When radio jamming is detected, the Control Panel will report the event accordingly.  Auto Check-in This  is  for  you  to  set  the  interval  time the  Control  Panel  waits  before  making  a  regular check-in report
 17  Interval: Set the interval waiting time  Offset Period: This  is to set the time delay  before the first “Auto Check-in Report” report  to  be  made.    For  example,  if  “Offset”  time period  is  set  to  2  Hours, then  the Control Panel will make the first “Auto Check-in Report” report after 2 hours,  High Temp. This is for you to set the High Temperature reporting threshold. If the Control Panel has learnt in a Temperature Sensor, it will make High Temperature report and raise alarm when the  temperature  exceeds  the  threshold.  When  the  temperature  drops  below  set  value again, the  Control  Panel will stop  alarming  and  send High Temperature Restore report. Factory default is set to Disable.  Low Temp This is for you to set the Low Temperature reporting threshold. If the Control Panel has learnt in a Temperature Sensor, it will make Low Temperature report and raise alarm when the temperature drops below the threshold. When the temperature rises above set value again,  the  Control  Panel  will  stop  alarming  and  send  Low  Temperature  Restore  report. Factory default is set to Disable.  Bypass Fault: This is for you to set whether  you want to  ignore fault events  regarding Ethernet or RF function.  Bypassed fault  events  will  not  displayed  under  Control  webpage  or  cause  the fault  LED  will  to  light  up  and  emit  beeps.  Please  refer  to  9.  Panel  Control  for  more information regarding system fault event management.  IP: When IP is selected, Ethernet related faults will be ignored.  RF: When RF is selected, RF related faults will be ignored. Factory default is set to Disable. After finishing the above settings, press “Submit” to confirm the change.  Time Zone This is for you to set your Time Zone.  Date & Time This is for you to set your current date and time. After finishing Time Zone and Date/Time setting, press “Adjust Time” to confirm the change.  Reset Press the “Reset” button to restart the Control Panel.  Factory Reset Press the “Factory Reset” button to clear all stored information and settings in the Control Panel, all settings will be returned to factory default. You can choose to tick  the box for “Keep Network Setting” or “Keep Device Setting” before pressing Factory Reset to keep part of the settings unchanged.
 18 5.4. Area   This page is for you to configure area settings.     Final Door  Final  Door  On: When the  system  is  Away Armed  with a  Door  Contact set  to  Entry attribute, the system will automatically arm the system once the Door Contact is closed even if the entry delay timer has not expired yet.  Final  Door  Off:  When the system  is  Away  Armed  with a  Door  Contact set  to Entry attribute, the system will only arm the system after the entry delay timer expires.    Factory Default is set to Final Door Off.  Arm Fault Type  Confirm: When  set to  Confirm,  If  you  attempt to  arm  when  a  fault  exists within the system, the arming action will  be prohibited, and a  message  will be displayed “Fault exists! Please Confirm!” You need to arm the system again to confirm your action and arm the system. (Factory Default)  Direct Arm: When set to Direct Arm, If you attempt to arm when a fault exists within the system, the system will enter selected arm mode without further notification about fault events.  Factory Default is set to Confirm.  Tamper Alarm  Away Arm: Tamper alarm will only be activated when tamper switch is triggered under Away Arm mode (Tamper event will still be reported normally in Home/Disarm mode).  Always: Tamper alarm will be activated whenever tamper switch is triggered.  Factory Default is set to Away Arm.  Entry Delay Set the Entry Delay Timer for Away Arm, Home Arm 1, Home Arm 2, and Home Arm 3 modes. When a device set to Entry attribute is triggered under arm mode, the Entry Delay Timer will begin to countdown. The system must be disarmed before the timer expires or an alarm will be activated.
 19 Factory default is set to 10 seconds.  Exit Delay   Set  the  Exit  Delay  Timer for  Away  Arm,  Home  Arm  1,  Home  Arm  2,  and  Home  Arm  3 modes. When you arm the system, the system will enter your selected arm mode after the Exit Delay Timer expires Factory default is set to 10 seconds.  Alarm Length   When  an  alarm  is  activated,  both  the  Control  Panel  siren  and  external  siren  will  raise alarm according to the Alarm Length setting. Factory default is set to 3 minutes.  Supervision Timer   Set the supervision timer for accessory devices, if no supervision signal is received within set duration for a certain device, the Control Panel will report the situation accordingly. Factory default is set to 12 hour.  Sound Setting    Door Chime: If not disabled, the Control Panel will sound a door chime sound when a Door Contact set to Entry attribute is activated in Disarm mode. .  Entry Arm: If not disabled, the Control Panel will sound beeping sounds when a Door Contact set to Entry attribute is activated in Away Arm mode. .  Entry Home: If not disabled, the Control Panel will sound beeping sounds when a Door Contact set to Entry attribute is activated in Home Arm mode. .  Exit  Arm: If not disabled, the Control Panel will sound beeping sounds when during Exit Delay Timer for Away Arm mode.  Exit Home: If not disabled, the Control Panel will sound beeping sounds when during Exit Delay Timer for Away Arm mode.  Warning Beep: If not disabled, the Control Panel will sound beeping sounds every 30 seconds when fault exists within system.
 20 5.5. Network   This page is for you to configure network settings.     DHCP  On: If DHCP is set to On, the Network will obtain the IP address automatically with a valid  Network  DHCP Server.  Therefore,  you  won’t  need  to  do  any  settings.  You  can only set DHCP to On if your Network environment supports DHCP. It will automatically generate all information.  Off: If DHCP is set to Off, you neet to enter the Network information manually for IP Address,  Subnet  mask,  Default  gateway,  Default  DNS.  Please  make  sure  that  you have  obtained  all  required  values  according  to  your  Network  environment.  Please contact your local service provider for more information.  SNTP SNTP setting is for you to enter an internet time server to synchronize and update Control Panel time automatically according to set interval times  SMTP SMTP setting is for you to program the mail server related settings. The email account you set  here  would  be  used  to  make  report  or  email  the  triggered  images/videos from  PIR Camera/Video Camera. For email destination, please refer to Report or Upload section. SMTP format: smtp://user:password@example.com  From name@example.com
 21 <<NNOOTTEE>>   SMTP setting must be entered in all lowercase letters  MZ-1/3/8 does not support SMTP encryption method such as SSL or TLS.  Administrator Account Setting Here you can program the user name and password used for accessing the webpage.  Web User: This is the user name you entered when you access the panel webpage. Default web user is “admin”. If you want to change the user name, enter a new name in the field. Maximum character allowed is 20.  New Password: If you want to change the password, enter the password in this field. Maximum character allowed is 20.  Repeat Password: Repeat the password again in this field After finishing above settings, click “Submit” to update settings.  XMPP XMPP  setting  enables  the  Control  Panel  to  query  the  set  destination.  This  setting  is required  for  the  Control  Panel  to  connect  to  Climax’s  Home  Portal  Server  for  further remote control.  XMPP: server address. ex: xmpp://user:password@example.com  Domain:   domain address  Buddy List: contact destination <<NNOOTTEE>>   XMPP setting must be entered in all lowercase letters
 22 5.6. Upload   This page is for you to set upload destination for captured pictures and videos from PIR Camera and PIR Video Camera.     1~5 Enter an email address, FTP address, server address, or mobile number for MMS delivery For email delivery, the SMTP setting under Network  must be completed. The format is: mailto: user@example.com For  MMS  delivery  to  mobile  phone  (MZ-8  only),  the  MMS  setting  under  RF  must  be completed. The format is: mms: 0987654321 For FTP, the format is: ftp://user.password@example.com:port/path For server, the format is: http://ip:port/path  Prefix Specify a prefix to be titled for every captured picture/video file.
 23 6. Device Management This page for you to learn in, edit, delete  and control all the accessory devices. A total of  40 devices are allowed to be learnt in to the system, including RF and ZigBee devices. Only 6 PIR Cameras (VST-852/VST-852 Pro) or Video Camera (VST-873/VST-873Pro) can be learnt into the system.           6.1. Learning   Step1.  Under  Disarm  Mode,  press  “Start  Learning”.  The  Control  Panel  will  enter  learning webpage. The Control Panel LED 1 will flash green.  Step2. Press the learn button on your device, for ZigBee device, press and hold the learn button for about 10 seconds (please refer to device manual for detail) to transmit a learn code.   Step3. If the Control Panel receives the learn code it will emit 2 short beeps, click the “Refresh” button to display the device information on webpage. If the Control Panel emit 1 long beep instead, it means the device has already been learned into the Control Panel. <<NNOOTTEE>>    If the Control emits 2 short beep when learning in ZigBee sensors, but does not display
 24 device information  when you  refresh  the  page,  it  means  the  Control  Panel received supervision code from the sensor instead of learn code. Please resend the learn code again.  Step4. Tick the device # box, then click “Add” to include the device in the Control Panel.  Step5. The Control Panel will display “Updated Successfully” message and the new learned in device zone accordingly. The device is now learn in to the system. Step6.  You  can  click  “Stop”  button  to  leave  learning  mode,  the  Control  Panel  will  return  to normal mode.
 25 Step7. After learning a device into the Control Panel, the Device Webpage will be changed to list all available functions.    Local Learning: The Control Panel feature local learning function for you to learn in the device without using the webpage Step1.  Press  and  hold the  learning  button  on  the  back  of  Control  Panel for  10  seconds  and release  when  you  hear  a  beep.  The  LED  1  will  begin  to  flash  green  to  indicate  the Control Panel is in learning mode. Step2.  Press  the  learn  button  on your  devices  to  transmit  a  learn  code,  if  the  Control  Panel receives the learn code, it will emit two beeps to indicated. The devices will be added into the Control Panel automatically.  Step3. After finish learning devices, press and hold the learn button on the back of Control Panel until the Control Panel emits 2 beeps to leave learning mode. Step4. Proceed to edit the device settings in the Control Panel Device webpage.
 26 6.2. Add Device For  RF  devices, you can  also  add device into the  Control Panel by entering the  device’s  RF code. (This function cannot be used with ZigBee devices) Step1. Select the zone number you want to assign the new device to Step2. Enter the device’s RF code Step3. Enter device name. Step4. Click “Add RF Device ” to include the device in the system.
 27 6.3. Walk Test   Step1.  Press “Start  Walk  Test”  under either  Learning  or  Device  Management webpage. The Control Panel will enter Walk Test page.  Step2.  Press  the  learn  button  on  your  device  (please  refer  to  device  manual  for  detail)  to transmit a test code. Step3. If the Control Panel receives the test code, it will emit a long beep, click the “Refresh” button to displayed accordingly on the webpage.  Step4. You can click “Stop” button to terminate walk test, the Control Panel will return to normal mode.
 28 6.4. Edit Device After you learn in a device to the system, you should proceed to edit its setting.  Step1. Under Device Management webpage, click “Edit”. The Control Panel will enter device editing page.  Step2. Proceed to edit device settings, click “Submit” when you are satisfied with all settings or information..
 29  Name: Enter a name for the device, A maximum of 20 characters are allowed  Zone: Select the device zone number.  Attribute:   For Door Contact you are requested to select the device attribute from Burglar, Home Omit,  Home  1/2  Omit,  Home  1/3  Omit,  Home  Access,  Delay  Zone,  Away  Only, Entry, Away Entry, 24 Hr, Fire, Medical Emergency, Water, Set/Unset Silent Panic, Personal Attack. For PIR Sensor, you are requested to select the device attribute from Burglar, Home Omit, Home 1/2 Omit, Home 1/3 Omit, Home Access, Delay Zone or Entry Zone.  For  Remote  Controller,  you  are  requested  to  select  the  device  attribute  from  Silent Panick or Personal Attack. Attribute List:  Burglar    When  the  system  is  in  any  Arm  mode,  if  a  “Burglar”  device  is  triggered,  a “Burglar Alarm” will be activated immediately and reported.    Home Omit    When  the  system  is  in  Home  Arm  1/2/3  mode,  if  a  “Home  Omit”  device  is triggered, the Control Panel will not raise alarm. It will still send a report for this event  When the system is in Full Arm mode, if a “Home Omit” device is triggered, the Control Panel will respond in the same way as if a “Burglar” device is triggered.   Home 1/2 Omit    When  the  system  is  in  Home  Arm  1/2  mode,  if  a  “Home  1/2  Omit”  device  is triggered, the Control Panel will not respond. It will still send a report for this event  When the system is in Away Arm or Home Arm 3 mode, if a “Home 1/2 Omit” device  is  triggered,  the  Control  Panel  will  respond  in  the  same  way  as  if  a “Burglar” device is triggered.  Home 1/3 Omit    When  the  system  is  in  Home  Arm  1/3  mode,  if  a  “Home  1/3  Omit”  device  is triggered, the Control Panel will not respond. It will still send a report for this event  When the system is in Away Arm or Home Arm 2 mode, if a “Home 1/2 Omit” device  is  triggered,  the  Control  Panel  will  respond  in  the  same  way  as  if  a “Burglar” device is triggered.  Home Access    When the system is in Home mode, if a “Home Access” device is triggered, the Control Panel will start an Entry Delay period to give enough time to disarm the system. It will also send a report for this event    When the system is in Full Arm mode, if a “Home Access” device is triggered,   the  Control  Panel  will  start  a  Burglar  Alarm  and  a  burglar  message  will  be reported.  Delay Zone  When the system is in any Arm mode, if a “Delay  Zone” device is triggered, a “Burglar Alarm” will be activated immediately and reported.
 30  When the system is in any Armed mode, and the Control Panel is counting down the  Entry  Delay,  if  a  “Burglar”  device  is  triggered,  the  Control  Panel  will  not respond.  During the Exit Delay period, if a “Burglar” device is triggered, the Control Panel will not respond .  Away Only  When the system is in Away Arm mode, if an “Away Only” device is triggered, a “Burglar Alarm” will be activated immediately and reported.    When  the  system  is  in  any  Home  Arm  mode,  if  an  “Away  Only”  device  is triggered, the Control Panel will not respond.  During the Entry Delay or Exit Delay period, if an “Away Only” device is triggered, the Control Panel will not respond .  Entry  When  the  system  is  in  any  Arm  mode,  if  an  “Entry”  device  is  triggered,  the Control Panel will start an Entry Delay countdown timer for the user to disarm the system.  After the delay period has expired and no correct PIN code has been entered, the Control Panel will activate a “Burglar Alarm” and the event will be reported.  When the system is in Disarm mode, if a “Entry” is triggered, the Control Panel will  make  a  “ding-dong”  Door  Chime  sound  (if  Door  Chime  function  is  not disabled).  Away Entry  When  the  system  is  in  Away  Arm,  if  an  “Away Entry”  device  is  triggered,  the Control Panel will start an Entry Delay countdown timer for the user to disarm the system.  After the delay period has expired and no correct PIN code has been entered, the Control Panel will activate a “Burglar Alarm” and the event will be reported.  When the system is in Disarm mode, if a “Entry” is triggered, the Control Panel will  make  a  “ding-dong”  Door  Chime  sound  (if  Door  Chime  function  is  not disabled).  When  the  system  is  in  any  Home  Arm  mode,  if  an  “Away Entry”  device  is triggered, the Control Panel will not respond.  During the Entry Delay or Exit Delay period, if an Away Entry device is triggered, the Control Panel will not respond  24 Hour  The  24  Hour  device  is  active  all  the  time  and  does  not  have  to  be  armed  or disarmed. An Event Code of #130 will be reported with trigger.  Fire    The Fire device is active all the time and does not have to be armed or disarmed.   An Event Code of #111 will be reported with trigger.  Medical Emergency  A  Medical  Emergency  device  is  active  all  the  time  and  does  not  have  to  be armed or disarmed. An Event Code of #101 will be reported with trigger.
 31  Water The  Water  device is  active  all  the  time  and  does  not  have  to  be  armed  or disarmed.    An Event Code of #154 will be reported with trigger.  Set/Unset (For Door Contact Only) If  the  Door  Contact  is  set to  Set/Unset,  the  system  will  be  disarmed when  the Door Contract is triggered, and armed when Door Contact is closed. <<NNOOTTEE>>    Please refer to Normal Open/Normal Close section below for further detail.  Silent Panic  If the device attribute is set  as  Silent Panic, when the device is activated, the Control Panel will report a Slient Panic alarm without sounding an audible siren. An event code of 122 will be reported.  Personal Attack  If the device attribute is set as Personal Attack, when the device is activated, the Control  Panel  will  activate  an  alarm  and  report  an  event  code  of  120  will  be reported.  Bypass: If Bypass is selected, the device will be deactivated. When a bypassed device is triggered, the Control Panel will not raise alarm.    Latch Report: If Latch Report is selected, the Control Panel will send report when the device is triggered.  Normal Open: This option is only available for Door Contact:   If Normal Open is selected, the Door Contact will be triggered when it is closed.   If Normal Open is selected, the Door Contact will be triggered when it is opened.    Group: This option is only available for Power Switch. You can assign multiple Power Switches to a group and control the group together <<NNOOTTEE>>    To avoid accidental tamper trigger, when you are changing device batteries or moving device  locations,  be  sure  to  use  the  Bypass  function  to  temporarily  deactivate  the device.  6.5. Delete Device In order to remove devices from the Control Panel, check the number boxes before the device name, then click Delete, the selected devices will be removed.    6.6. Request Media You can manually control the selected PIR Camera and PIR Video Camera to take a picture or record a 10-second video clip. The requested picture and video clip can be viewed in “Captured Event” webpage.
 32 6.7. Power Switch Control This section is for you to control Power Switch in the system  Switch On:    Select the desired Power Switch, then choose the time length you want to turn on the Power Switch, then click “Switch On” to confirm.    Switch Off: Select the desired Power Switch, then click “Switch Off” to turn off.  Switch Toggle: Select the desired Power Switch, the click “Switch Toggle.” If the Power Switch is on, it will be turned off; if the Power Switch is off, it will be turned on instead.  Switch Level (%): This function is for Power Switch with Dimmer function only. Select the desired Power Switch with Dimmer, then choose the power level percentage you want to adjust. Click “Switch Level %” to confirm the change.  Group  Switch  On:    You  can  control  Power  Switches  assgined  to  one  group  together. Select the desired Power Switch group, then choose the time length you want to turn on the Power Switches, then click “Group Switch On” to confirm.  Group Switch Off: Select the desired Power Switch group, then click “Group Switch Off” to turn off.  6.8. Siren Learning/Control This section is for you to learn in Indoor Siren or Outdoor Bell Box, and edit their settings.  Learn Siren: To learn in siren: 1. Put the siren into learning mode (Please refer to siren manual for detail) 2. Click “Learn Siren” to transmit a learn code. 3. Refer to siren manual to complete the learn in process.  Siren Tamper: This is for you to enable/disable the siren tamper protection. Select On/Off, then click “Siren Tamper” to confirm setting.  Confirm: This  is  for  you to  set  whether  the  siren  should  emit  beeping sound  when  the system is armed or disarmed. Select On/Off, then click “Confirm” to confirm setting.  Entry Sound: This is for you to set whether the siren should beep warning sound during Entry Delay coundown timer. Select On/Off, then click “Confirm” to confirm setting. <<NNOOTTEE>>    When you are changing Siren batteries or moving Siren mounting location, you need to first deactivate the siren by selecting Bypass is siren edit screen, then turn off the Siren Tamper to avoid accidental tamper trigger.
 33 7. Captured Events Pictures/Videos captured by PIR Camera and PIR Video Cameras will be displayed in this page. Only the pictures/videos of the 6 latest events will be stored.  Click on the image or video to view the file.  Time: The time when the picture/video is captured.  Device: The Zone number of the PIR Camera/Video Camera triggered.  Type: The type of the image/video.    Alarm Image: When triggered under Away Arm/Home Arm mode, the PIR Camera will take three pictures.  Requested Image: You can manually request the PIR Camera to take one picture.  Alarm  Video:  When  triggered  under  Away  Arm/Home  Arm  mode,  the  PIR  Video Camera will record a 10-second video clip.  Requested  Video:  You  can  manually  request  the  PIR  Video  Camera  to  take  a 10-second clip.  Status: The staus of the captured event are listed as follows:  Waiting for Media Ready: The PIR Camera/Video Camera has captured image/video and  will  send  the  image  video  to  Control  Panel  after  the  file  is  ready.  For  Alarm Image/Video,  if  you  disarm  the  Control  Panel  under  this  status,  the  captured image/video will be deleted and no image/picture will be sent.
 34  Waiting  for  Capture:  The  PIR  Camera/Video  Camera  is  sending  captured picture/video the the Control Panel. For Alarm Image/Video, if you disarm the Control Panel under this status, the captured image/video will be deleted and no image/picture will be sent.  Upload: The PIR Camera/Video Camera has finished sending image/picture to Control Panel. The Control Panel is now uploading the image/video to programmed destination.  Done: The Control Panel has finished uploading image/video successfully  Fail:  The  PIR  Camera/Video  Camera  was unable  to  send  captured  image/picture to Control Panel. Please check if the PIR Camera/Video Camera is out of order or under Low Battery, then perform Walk Test to check signal strength.  Timeout:  The  PIR  Camera/Video  Camera  did  not  respond  to  Control  Panel.  Please check  if  the  PIR  Camera/Video  Camera  is  out  of  order  or  under  Low  Battery,  then perform Walk Test to check signal strength. <<NNOOTTEE>>    If a PIR Camera/Video Camera is triggered when the system is armed. Do not disarm the  alarm  system  before  the  status  displays  “Upload”  or  “Done.”  Otherwise  the image/video will be deleted and will not be sent to Control Panel.
 35 8. History Records  8.1. History   The Control Panel history events are recorded in this page.            The History memorizes the last 50 Panel events including:  All Alarm Events with Device Zone-  All Fault Warning Events from Panel or Device  All Arming And Disarming Events by Panel and Remote Controller  All  Arming  and  Disarming  Events  by  Remote  Keypad  with  User   information.  Time: The time when the event take place  Device : The device that triggered the event  User: The user who perform the event action  Event: The event content
 36 8.2. Reported Event The reported event history are recorded in this page..          A total of 50 reported events can be recorded with Time, CID Event Code, Device Group/Zone and User information.  Time: The time when the Control Panel begins the report  CID Event Code Format: The CID event code is recorded in 4 digits format of “Prefix + Event Code”  Prefix: “1” represents events taking place. “3” represents event restore.  Event Code: 3-digit CID event code. For Example: “1302” means “Low Battery”, and “3302” means “Low Battery Restore.”  Group: The group the device belongs to  Zone/User:   For arming/disarming, the User PIN # will be displayed. For device triggering, the device zone will be displayed.
 37 9. Panel Control Under this page, you can choose to Away Arm, Home Arm 1/2/3, or Disarm the system. If any fault exists within the system, they will be displayed under this page.   Current Mode Control Panel current mode.  Away Arm: Away Arm will arm all devices in the system.  Home Arm 1/2/3: You can choose to arm the system in 3 different Home Arm mode.    Under  Home  Arm  1,  device  set  to  Home  Omit,  Home  1/2  Omit  or Home 1/3 Omit will not raise an alarm when triggered.  Under Home Arm 2, device set to Home Omit or Home 1/2 Omit will not raise an alarm when triggered.  Under Home Arm 3, device set to Home Omit or Home 1/3 Omit will not raise an alarm when triggered.  Fault Events Fault events in system are listed in the Fault section. If you try to arm the system when fault event exists a warning message “Fault Exists! Please Confirm!” will be displayed to notify you. You will need to arm the system again to force arm the system. Alternatively, you can select the fault events and click “Clear” to  ignore the fault events. Cleared fault event will no longer prevent you from arming the system. If all fault events are cleared, the fault LED will no longer light up or flash.
 38  10. Home Automation This page is for you to setup Home Automation rules with condition and execution setting to control the alarm system or home appliance automatically. A total of 20 Home Automation rules are available for setting.  Step1. Click “Edit” to configure setting for the selected rule number. You will enter edit page.  Step2. Set the Rule Condition.  Mode Changed: The rule will be activated when the system mode is change to set mode.    Alarm: The rule will be activated when the set alarm event is triggered.
 39  Greater Temp: The rule will be activated when the temperature rises above set value.    Lower Temp: The rule will be activated when the temperature drops below set value.    Timer: The rule will be activated when system reaches set time Step3. Set the Execution Rule  Switch Group: All Power Switches in selected group will be turned On/Off for set duration according to your setting.  Switch Zone: All Power Switches in selected zone will be turned On/Off for set duration according to your setting.  Request All Media: All PIR Camera/Video Camera in the alarm system will be requested to take a picture or record a 10-second video clip. Step4. Click “Submit” to confirm the rule change. 11. Firmware This page is for you update your Control Panel firmware.  Step1. Select the firmware file in your computer Step2. Click “Submit” to upload the firmware file to Control Panel.   Step3. It takes several minutes to complete update, do NOT power off during the process. Step4. Once updating is complete, the Control Panel will reboot automatically.   12. Alarm Activation Table For Alarm Activation by Events and Control Panel Responses, please refer to the following table: Control Panel Mode & Response Table
 40
 41   Press “Save”. A message edit screen will appear for you to confirm.    Press “Send” to send the command to panel. <<NNOOTTEE>>   For system mode change (Arm, Home, Disarm), the Power Switch Ggroup selection is limited to #1 only.  For High/Low Temperature and Time setting. You can select any Power Switch group from #1 ~ #4.
 42 14. Event Code The events are reported with a qualifier before the event code. The qualifier “1” means the event has  taken  place,  “3”  means  the  event  has  been  restored.  For  example,  if  the  Control  Panel reports “1302”, it means the panel  is under low battery; if the Control Panel reports “3302”. It means the panel low battery condition has been restored.  100 – Medical  101 – Personal emergency   When the Wrist Transmitter / Emergency Pendant (WTR) is pressed.  102 – Inactive  110 – Fire  111 – Smoke   When the Smoke Detector (SD) is triggered.  114 – Heat   When the Heat Detector (HD) is triggered.  120 – Panic   When the Panic Button of the Remote Controller (RC) is pressed.  121 – Duress     When the Duress Code is entered to disarm or arm the system.  122 – Silent Panic     When the panic button on a Remote Controller (RC) set to silent panic is pressed.  130 – Burglar   When any one of the following devices is triggered:     The Door Contact (DC) set at Burglar (@ B)   The Door Contact (DC) set at 24 Hours (@ H)   The Door Contact (DC) set at Delay (@ D)       The PIR set at Burglar (@ B)   The PIR set at Delay (@ D)  131 – Burglar Perimeter   When a device set as Entry is triggered in away arm mode.  132 – Burglar Interior   When a device set at Entry is triggered in the home mode.  137 – Panel Tamper     When the Control Panel tamper switch is triggered.  147 – Sensor Supervision Failure   When  MZ-1/8  fails  to  receive  the  signal  transmitted  from  any  one  of  the  devices individually for a preset period.  151 – Gas  154 – Water leakage   When a Water Sensor or Door Contact set as Water is triggered.
 43  158 – High Temperature   When the temperature exceeds High Temperature setting.  159 – Low Temperature   When the temperature drops below Low Temperature setting.  162 – CO detector  301 – AC Failure   When the AC power fails for more than 10 sec.  302 – Low Battery   When the Control Panel is under low battery.  311 – Panel Battery Missing/Dead   When the Control Panel Battery is missing or disconnected.  344 – Interference  374 – Arm with Fault     When  fault  exists in  system,  and the  system is armed  by confirming the arm  action. (Arm Fault Type set to Confirm.)  383 – Device Tamper   When a device’s tamper switch is triggered.  384 – Device Low Battery   When a device’s is under low battery.  389 – Self Test Failure  400 – Arm/Disarm (by Remote Controller)   When the system is armed or disarmed by using the Remote Controller.  401 – Arm/Disarm by Panel   When the system is armed or disarmed by entering the PIN code.  408 – Set/Unset Disarm  407 – Disarm/Away Arm/Home Arm by Remote Keypad  456 – Home Arm  465 – Alarm Reset  570 – Zone Bypass   When fault exists in system, and the system is armed by ignoring the fault event. (Arm Fault Type set to Direct Arm)  602 – Periodic test report   When MZ-1/8 makes periodic Check-in reporting.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)  This  device  must  accept  any  interference  received,  including  interference  that  may  cause undesired operation.