Cochlear CP1000 Sound Processor in a Cochlear Implant System User Manual Users guide
Cochlear Limited Sound Processor in a Cochlear Implant System Users guide
Cochlear >
Users guide
DRAFT ONLY FOR CLINICAL TESTING NucleusÂŽ 7 Sound Processor User Guide CP1000 592753_1-06_EN_CP1000_UG_EMEA.indd 1 14/06/2016 1:22:53 PM DRAFT ONLY FOR CLINICAL TESTING This guide is intended for Cochlear implant recipients and their carers using the Cochlear⢠NucleusÂŽ 7 Sound Processor (model number: CP1000). The processor works with your implant to transfer sound to your ear, and is made up of a processing unit, earhook, coil and cable, and a battery module. You can power your processor with disposable or rechargeable batteries. You can control your processor by pressing its button, or by using your Cochlear Nucleus 7 Remote Control or the Nucleus Smart app. People with certain types of hearing loss can wear the processor in Hybrid⢠mode by adding an acoustic component which sends amplified acoustic sound into the ear canal. A number of tools and accessories are supplied with your processor. NOTES ⢠Refer to the relevant sections for cautions and warnings relating to the use of the Nucleus 7 Sound Processor, batteries and components. ⢠Please also refer to your Important Information document for essential advice that applies to Cochlear implant systems. Symbols used in this guide NOTE Important information or advice. TIP Time saving hint. CAUTION (no harm) Special care to be taken to ensure safety and effectiveness. Could cause damage to equipment. WARNING (harmful) Potential safety hazards and serious adverse reactions. Could cause harm to person. II 592753_1-06_EN_CP1000_UG_EMEA.indd 2 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:22:53 PM DRAFT ONLY FOR CLINICAL TESTING Nucleus 7 Sound Processor Coil Microphones and microphone protectors Indicator light Earhook Serial number Coil cable Nucleus 7 processing unit ABOUT Control button Coil magnet Battery module Made for iPhone (MFi) Your sound processor is a Made for iPhone (MFi) hearing device. This allows you to control your sound processor with some iPhoneÂŽ and iPod touchÂŽ devices using the Cochlear Nucleus Smart app. Please see the appâs user guide for details. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 1 14/06/2016 1:22:53 PM DRAFT ONLY FOR CLINICAL TESTING Contents Power Batteries . . . . . . . . . . . . . . . . . . . Battery life . . . . . . . . . . . . . . . . . . Lock the battery module to the processor Lock the disposable battery module cover Replace the battery module . . . . . . . . Change disposable batteries . . . . . . . . Charge rechargeable batteries . . . . . . . .4 .5 .6 .7 .8 10 12 Use Turn on and off . . . . . . . . . Pair with remote or app. . . . . Lock the control button. . . . . Change program . . . . . . . . Change volume and sensitivity. Telecoil . . . . . . . . . . . . . Wireless accessories. . . . . . . Use monitor earphones . . . . 18 19 19 20 20 21 22 24 26 27 28 29 32 35 36 37 Wear Wear your processor . . . . For users with two implants Change earhooks . . . . . . Retention accessories . . . . Wear the Headband. . . . . Sport and exercise . . . . . Travel . . . . . . . . . . . . Flight mode . . . . . . . . . 592753_1-06_EN_CP1000_UG_EMEA.indd 2 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:22:53 PM DRAFT ONLY FOR CLINICAL TESTING Care Regular care . . . . . . . . Battery charger care . . . Storage . . . . . . . . . . Water, sand and dirt . . . Change microphone cover Change the coil and cable Change the coil magnet . Lights and Beeps Troubleshoot Cautions 38 40 41 42 44 46 47 . . . . . . . . . . . . . 48 . . . . . . . . . . . . . . . . 54 . . . . . . . . . . . . . . . . . . . . .61 Warnings For parents and carers. Processors and parts . Batteries . . . . . . . . Medical treatments . . Other information 62 64 67 69 . . . . . . . . . . . .72 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 3 14/06/2016 1:22:53 PM DRAFT ONLY FOR CLINICAL TESTING Batteries You have a choice of three battery types for the Nucleus 7 Sound Processor: The disposable battery module consists of: ⢠Cochlear Nucleus 7 Battery Cover ⢠Cochlear Nucleus 7 Battery Holder It uses two disposable batteries and has a tamper-resistant lock. The Cochlear Nucleus 7 Standard Rechargeable Battery Module The Cochlear Nucleus 7 Compact Rechargeable Battery Module 592753_1-06_EN_CP1000_UG_EMEA.indd 4 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:22:54 PM DRAFT ONLY FOR CLINICAL TESTING Battery life Batteries should be replaced as needed just as you would with any other electronic device. Battery life varies according to the programs used each day, your implant type, the thickness of skin covering your implant, and the size and type of battery. The rechargeable batteryâs lifespan is at least 400 charge cycles. A completely empty rechargeable battery will take approximately four hours to recharge. Rechargeable batteries may take longer to fully recharge with age. To get the longest life from the rechargeable batteries, always recharge before use. To help you get the longest life from the batteries, your sound processor will turn off two minutes after you take it off your implant, if enabled by your clinician. POWER NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 5 14/06/2016 1:22:54 PM DRAFT ONLY FOR CLINICAL TESTING Lock the battery module to the processor To increase tamper resistance, the battery module can be locked to the sound processor. 1. Use your battery cover locking tool to push the lock to the far left to lock the battery module. 2. Push the lock to the far right to unlock the battery module. CAUTION Always check this lock is unlocked before attaching or removing the battery module. 592753_1-06_EN_CP1000_UG_EMEA.indd 6 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:22:56 PM DRAFT ONLY FOR CLINICAL TESTING Lock the disposable battery module cover The disposable battery module has a tamper-resistant lock to help prevent children opening the battery cover. POWER LOCK Turn the locking screw clockwise with the battery cover locking tool until it is in a horizontal position. UNLOCK Turn the locking screw anticlockwise until it is in a vertical position. CAUTION Always check the locking screw is unlocked before attaching or removing the battery cover. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 7 14/06/2016 1:22:56 PM DRAFT ONLY FOR CLINICAL TESTING Replace the battery module Remove the battery module 1. Twist the battery module as shown to release it from the processing unit. 2. Pull the battery module from the processing unit. 592753_1-06_EN_CP1000_UG_EMEA.indd 8 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:22:56 PM DRAFT ONLY FOR CLINICAL TESTING Attach the battery module 1. Align the battery module to the processor socket to fit the parts together. Rechargeable battery modulesâ align raised marker on battery module with back of processing unit Disposable battery moduleâ align indents and lock on battery module with back of processing unit POWER 2. Twist the battery module as shown to attach the parts. Your processor will turn on automatically. NOTE If you do not put your processor on your implant, it will turn off automatically after two minutes, if enabled by your clinician. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 9 14/06/2016 1:22:57 PM DRAFT ONLY FOR CLINICAL TESTING Change disposable batteries The disposable battery module uses two high power zinc air batteries. Cochlear recommends 675 (PR44) zinc air batteries designed for cochlear implant use. Do not use silver oxide or alkaline batteries. 1. Press and hold the button for 5 seconds, then release to turn off your processor. 2. Pull the unlocked battery cover away from the battery holder. 3. Remove the batteries from the battery holder. 10 592753_1-06_EN_CP1000_UG_EMEA.indd 10 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:22:57 PM DRAFT ONLY FOR CLINICAL TESTING 4. Remove the new batteries from the packet, and let them stand for a few seconds. 5. Insert the batteries into the battery holder with the flat side (positive terminal) facing up. POWER 6. Replace the battery cover by sliding it up towards the processing unit. Lock the cover if required Your processor will automatically turn on. NOTE If you do not put your processor on your implant, it will turn off automatically after two minutes, if enabled by your clinician. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 11 11 14/06/2016 1:22:58 PM DRAFT ONLY FOR CLINICAL TESTING Charge rechargeable batteries There are two chargers that can be used with the rechargeable battery modules: ⢠Cochlear Nucleus 7 Y Battery Charger (see page 14) ⢠Cochlear Nucleus 7 USB Battery Charger (see page 16). Before you start Your Nucleus 7 rechargeable battery module has built-in safety and monitoring features. Read this section before using your battery charger. SLEEP MODE After manufacture, new rechargeable battery modules are put into âsleep modeâ which lasts for up to 2 years. This keeps some power in the battery, as a completely flat battery wonât charge. WHAT DO I DO? Before using a new battery module, you need to âwake it upâ by connecting it to a charger until it is fully charged. STORING BATTERIES Your rechargeable battery module will lose some power if you do not use it for a period of time. WHAT DO I DO? Charge your battery module before storing it. CHARGING TEMPERATURE Rechargeable battery modules have a built-in temperature sensor. New batteries must be charged at 0 â 45° C (32 â 113° F). If battery module temperature is outside this range, the LED will flash orange (error). WHAT DO I DO? Charge new rechargeable battery modules at a room temperature of 0 â 45° C (32 â 113° F). 12 592753_1-06_EN_CP1000_UG_EMEA.indd 12 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:22:58 PM DRAFT ONLY FOR CLINICAL TESTING FLAT BATTERIES Even if your rechargeable battery module goes flat while being used with your Nucleus 7, it should hold some battery life. This means you can recharge a flat battery module up to 1 year after running it flat. WHAT DO I DO? Charge your flat battery module after use. NOTE If a rechargeable battery module is too flat to charge, the LED will flash orange (error). BATTERY HEALTH CHECK POWER Rechargeable battery modules have a built-in âhealth checkâ. If it detects a problem, it will turn the battery off. If the problem is fixed, the battery will turn back on again. WHAT DO I DO? If a battery turns off, disconnect and reconnect it to your processor. If this does not restore power, contact your clinician. CONNECTING TO ACCESSORIES Some accessories (e.g. monitor earphone adaptor, FM adaptor) are âsandwichedâ between the rechargeable battery module and your processing unit. If you leave them attached after use, this will drain the battery. WHAT DO I DO? Donât leave your battery module attached to an accessory after use. Donât attach an accessory with a rechargeable battery module attached to the battery charger. This will cause an error. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 13 13 14/06/2016 1:22:58 PM DRAFT ONLY FOR CLINICAL TESTING Use the Y Battery Charger The Y Battery Charger can charge two rechargeable battery modules at once. It uses the supplied USB cable to plug into: ⢠a wall power outlet using the supplied power adaptor plug, or ⢠a USB port (e.g. computer). Power cable Rechargeable battery module connector LED indicator 14 592753_1-06_EN_CP1000_UG_EMEA.indd 14 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:22:58 PM DRAFT ONLY FOR CLINICAL TESTING 1. Connect the rechargeable battery module to the charger. 2. Twist to lock. 3. Plug the charger into a power outlet or USB port. The LED flashes green while charging. POWER USB 4. The LED changes to steady green when the module is fully charged. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 15 15 14/06/2016 1:22:59 PM DRAFT ONLY FOR CLINICAL TESTING Use the USB Battery Charger The USB Battery Charger can charge one rechargeable battery module at a time. It uses a USB connector to plug into: ⢠a wall power outlet using the supplied cable and power adaptor plug, or ⢠a USB port (e.g. computer). USB connector Rechargeable battery module connector LED indicator 16 592753_1-06_EN_CP1000_UG_EMEA.indd 16 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:01 PM DRAFT ONLY FOR CLINICAL TESTING 1. Remove the covers from the charger. 2. Connect the rechargeable battery module to the charger. POWER 3. Plug the charger into a power outlet or USB port. The LED flashes green while charging. USB 4. The LED changes to steady green when the module is fully charged. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 17 17 14/06/2016 1:23:05 PM DRAFT ONLY FOR CLINICAL TESTING Turn on and off 1. To turn on either: ⢠Connect the battery (see page 9), or ⢠If the battery is already connected, short press the button. 2. To turn off, either: ⢠Disconnect the battery (see page 8), or ⢠Press and hold the button for 5 seconds, then release. The light will change to steady orange as the processor turns off. NOTE Your processor will also turn off automatically after being off your implant for two minutes, if enabled by your clinician. 18 592753_1-06_EN_CP1000_UG_EMEA.indd 18 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:06 PM DRAFT ONLY FOR CLINICAL TESTING INDICATOR LIGHTS WHAT IT MEANS Turning on processor. The number of flashes indicates the number of the current program. Green flashes ⌠Quick green flashes Processor flashes while receiving sound from microphones (Child mode only). ... Orange flashes Processor is off the implant. Processor is turning off. Long flash of orange USE Pair with remote or app You need to pair your sound processor to your Nucleus 7 Remote Control or the Nucleus Smart app to use their control and monitoring functions. Please see their user guides for details. Lock the control button You can lock the sound processorâs control button using the Nucleus Smart app. Please see its user guide for details. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 19 19 14/06/2016 1:23:06 PM DRAFT ONLY FOR CLINICAL TESTING Change program You can choose between programs to change the way your sound processor deals with sound (e.g. in noisy or quiet places). Usually two programs are all you need, but your clinician can give you up to four programs. 1. Short press the button to switch between programs. NOTE If your clinician has enabled SCAN, your sound processor can automatically select the best program for you. INDICATOR LIGHT Green flashes WHAT IT MEANS Changing the program (Child mode only). The number of flashes indicates the number of the current program Change volume and sensitivity If set up by your clinician, you can control the levels of volume or sensitivity (if available) using your Nucleus 7 Remote Control or the Nucleus Smart app. Please see their user guides for details. 20 592753_1-06_EN_CP1000_UG_EMEA.indd 20 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:07 PM DRAFT ONLY FOR CLINICAL TESTING Telecoil Your clinician can enable telecoil if you want to listen to room hearing loops. NOTE Telecoil is not recommended for phone use with the Nucleus 7 Sound Processor. We recommend you use the Cochlear Wireless Phone Clip. See Wireless accessories on page 22. TIP You can also use your remote or the Nucleus Smart app to control telecoil. See their user guides for details. 1. Press and hold the button for 2 seconds then release to turn on telecoil. USE Blue: telecoil is on. 2. Short press the button to turn off telecoil. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 21 21 14/06/2016 1:23:09 PM DRAFT ONLY FOR CLINICAL TESTING Wireless accessories Cochlear True Wireless⢠Accessories can wirelessly stream sound to your processor: ⢠The Mini Microphone or TV Streamer are controlled from your processor. ⢠You use the Phone Clip controls for phone calls. NOTE You first need to pair your wireless accessories with your sound processor. See their user guide for details. TIP You can also use your remote or the Nucleus Smart app to control wireless accessories. See their user guides for details. Each button press cycles you through telecoil (if enabled), and then your wireless accessories (in the order in which they were paired to your processor). Scenario 1: Telecoil is enabled PRESS 4... STREAMED AUDIO Telecoil Wireless accessory 1 (e.g. Mini Microphone) Wireless accessory 2 (e.g. TV Streamer) Telecoil... Scenario 2: No telecoil PRESS 4... STREAMED AUDIO Wireless accessory 1 (e.g. Mini Microphone) Wireless accessory 2 (e.g. TV Streamer) Wireless accessory 3 (e.g. extra Mini Microphone) Wireless accessory 1... 22 592753_1-06_EN_CP1000_UG_EMEA.indd 22 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:09 PM DRAFT ONLY FOR CLINICAL TESTING 1. Press and hold the button for 2 seconds then release to stream audio. Press and release again if you need to cycle to the next audio source. Blue: streaming audio. 2. Short press the button to stop streaming. USE NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 23 23 14/06/2016 1:23:10 PM DRAFT ONLY FOR CLINICAL TESTING Use monitor earphones Carers can use monitor earphones to check that a Cochlear implant recipient is receiving sound, and that functions like telecoil or wireless accessories are working. NOTES ⢠Only use approved earphones/headphones with the monitor earphone adaptor (ones with a 3- or 4-pin audio jack that fits the adaptor). You CAN use earbuds. You CANNOT use noise-cancelling headphones. ⢠Donât connect multiple monitor earphone adaptors in series. ⢠Donât connect the monitor earphone adaptor to other audio outputs, e.g. computer. 1. Twist to disconnect, then remove the battery module. 2. Insert the Cochlear Nucleus 7 Monitor Earphone Adaptor, then twist to connect. 24 592753_1-06_EN_CP1000_UG_EMEA.indd 24 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:12 PM DRAFT ONLY FOR CLINICAL TESTING 3. Insert the battery module, then twist to connect. 4. Plug the monitor earphones into the adaptor. USE NOTE Use only Cochlearapproved earphones. Ask your clinician for guidance 5. Use the earphones to check that the recipient is hearing sound. NOTE Do not put the sound processor on the recipientâs implant. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 25 25 14/06/2016 1:23:13 PM DRAFT ONLY FOR CLINICAL TESTING Wear your processor 1. Place the processor on your ear, letting the coil dangle. 2. Move the coil sideways and onto your implant. INDICATOR LIGHTS WHAT IT MEANS Processor flashes while coil is off Flash of orange every second (or connected to the wrong implant). 26 592753_1-06_EN_CP1000_UG_EMEA.indd 26 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:14 PM DRAFT ONLY FOR CLINICAL TESTING For users with two implants Ask your clinician to give you coloured stickers (red for right, blue for left) to make identifying left and right processors easier. CAUTION If you have two implants, you must use the correct sound processor for each implant. NOTE Your sound processor will recognise the implantâs ID, so it will not work on the wrong implant. WEAR NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 27 27 14/06/2016 1:23:14 PM DRAFT ONLY FOR CLINICAL TESTING Change earhooks The Cochlear Nucleus 7 Earhook comes in small, medium and large sizes. For extra help wearing your processor securely and safely, see Retention accessories on page 29. NOTE Remove your earhook only when necessaryâit may become loose if it is removed too often. 1. Pull up on the earhook to remove it. 2. Click the new earhook into place. 28 592753_1-06_EN_CP1000_UG_EMEA.indd 28 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:16 PM DRAFT ONLY FOR CLINICAL TESTING Retention accessories A range of optional Cochlear Nucleus 7 accessories are available to help you wear your sound processor securely and safely. NOTE Hybrid mode cannot be used with retention accessories. They either position the sound processor off the ear, or use a custom earhook which means the acoustic component cannot be fitted. Nucleus 7 Tamper Resistant Earhook A small earhook for young children. An extra hook holds it in place to reduce the risk of it becoming a choking hazard. WEAR Nucleus 7 Snugfit Holds your sound processor more securely in place than an earhook alone. Available in small, medium and large. Nucleus 7 Hugfit⢠Holds a childâs sound processor in place more securely than an earhook alone. Carers can access controls and accessories. In three sizes to suit small ears. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 29 29 14/06/2016 1:23:17 PM DRAFT ONLY FOR CLINICAL TESTING Nucleus 7 Earmould Adaptor Allows you to attach a custom earmould to hold your sound processor in place more securely than an earhook alone. NOTE The custom earmould is not supplied by Cochlear. Nucleus 7 Koala Clip Holds your sound processor so you can clip it onto your clothing. Great for chidren. NOTE You will need to use a coil with a longer cable. Nucleus 7 Headworn Adaptor Holds your sound processor and coil, so you can wear them on your head. NOTES ⢠Headworn comes in right or left side models â your processor needs to face the same way as when you wear it on your ear. ⢠Headworn works best with a 6, 8 or 11 cm coil cable, a compact rechargeable battery module and a stronger magnet. 30 592753_1-06_EN_CP1000_UG_EMEA.indd 30 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:23 PM DRAFT ONLY FOR CLINICAL TESTING Cochlear⢠Safety Cord Clips to clothing so active people are less likely to lose their sound processor. Available in single or double (for users with two processors). Nucleus 7 Headband Holds your sound processor and coil in place. Great for active adults and children. Has pockets for left and right side sound processors. WEAR NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 31 31 14/06/2016 1:23:27 PM DRAFT ONLY FOR CLINICAL TESTING Wear the Headband The Cochlear Headband is an optional accessory that holds the processor in place on your implant. This is useful for children or for physical activities. Headband sizing To choose a headband, measure your head circumference: SIZE CIRCUMFERENCE SIZE CIRCUMFERENCE XXS 41-47 cm 52-58 cm XS 47-53 cm 54-62 cm 49-55 cm NOTE The headband may affect your sound processorâs performance. If you notice any change, contact your clinician. Fitting the Headband 1. Open the headband and lay it flat, with the processor pockets facing up. Velcro Left processor pocket 32 592753_1-06_EN_CP1000_UG_EMEA.indd 32 Anti-slip strip (for forehead) Right processor pocket Velcro NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:27 PM DRAFT ONLY FOR CLINICAL TESTING 2. Insert your processor(s) in the correct pocket(s): ⢠the left processor in the left-side pocket, the right processor in the right-side pocket ⢠the side of the coil that fits onto your implant is facing up towards you. 3. Push the coil through the slit in the headband. WEAR 4. Pick up the ends of the headband, and place the anti-slip section against your forehead. 5. Join the ends behind your head. Adjust the velcro so the headband fits firmly, with your processor(s) over your implant(s). 6. Press firmly on the ends to make sure they join together. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 33 33 14/06/2016 1:23:33 PM DRAFT ONLY FOR CLINICAL TESTING Sport and exercise TIP Always ensure the battery cover and battery modules are locked when you exercise or play sport. NOTE If you want to use your processor around water, ask your clinician about the Cochlear Nucleus 7 Aqua+. 1. Use retention accessories such as the Snugfit, Safety Cord or Headband to help hold your processor in place when you play sport or exercise. 34 592753_1-06_EN_CP1000_UG_EMEA.indd 34 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:39 PM DRAFT ONLY FOR CLINICAL TESTING 2. After exercise, wipe your processor with a soft cloth to remove sweat or grime. WEAR 3. Then check your microphone protectors for dirt. See Change microphone cover on page 44. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 35 35 14/06/2016 1:23:42 PM DRAFT ONLY FOR CLINICAL TESTING Travel NOTE Visit www.cochlear.com/clinic-finder to find the nearest clinic in places you are travelling. ⢠Take a printout from your clinician of your most recent program in case you need help with your processor. ⢠If you have a backup sound processor, check that it is programmed correctly and take it with you. ⢠Itâs okay to move through metal detectors and full body scanners with your sound processor on. To avoid any possible buzzing sounds in your ear, turn off the telecoil. ⢠Ask your clinician for a Patient Identification Card. In the unlikely event that your implant sets off a metal detector the ID card will help explain that you have an implanted medical device. ⢠If you need to remove your sound processor as you move through airport security, place it in a case in your hand luggage. ⢠Your sound processor transmits high frequency radio waves when switched on, and may need to be placed in a flight-safe mode during takeoff and landing. Check with airline staff before flying if you are unsure. 36 592753_1-06_EN_CP1000_UG_EMEA.indd 36 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:42 PM DRAFT ONLY FOR CLINICAL TESTING Flight mode NOTE In flight mode, you can change programs as normal using the processor button. You can only use telecoil to stream audio, as True Wireless Accessories will not be available. To enter flight mode: 1. Disconnect the battery. WEAR 2. Press and hold the button (1) while reconnecting the battery (2). Release the button when the green light comes on. To exit flight mode: 1. Disconnect and reconnect the battery. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 37 37 14/06/2016 1:23:50 PM DRAFT ONLY FOR CLINICAL TESTING Regular care CAUTIONS ⢠Do not use cleaning agents or alcohol to clean your processor. ⢠Turn your processor off before cleaning or performing maintenance. Every day ⢠Check all parts and any accessories you use (e.g. Snugfit) for dirt or moisture. Wipe the processor, coil, cable, earhook and accessories with a soft dry cloth. (You can leave accessories on the processor while cleaning.) ⢠Keep your processor free from moisture by drying it every night in your dry aid kit. ⢠Remove the battery module and make sure all the contacts are clean. Carefully tap or blow on them to remove any dirt. Wipe the contacts with a soft dry cloth. ⢠Keep accessories clean. Blow on connectors to remove any dust and clean accessories with a soft dry cloth. ⢠Check the microphone protectors for signs of dirt or grime and replace if needed. See Change microphone cover on page 44. 38 592753_1-06_EN_CP1000_UG_EMEA.indd 38 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:50 PM DRAFT ONLY FOR CLINICAL TESTING Every month Check if earhooks or retention accessories are becoming loose or showing signs of wear. Replace as needed. See Change earhooks on page 28, or your retention accessoryâs instructions. Every two months ⢠Replace the dry brick in your dry aid kit. Every three months ⢠Replace the microphone coverâthis is very important for the quality of sound. See Change microphone cover on page 44. CARE NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 39 39 14/06/2016 1:23:50 PM DRAFT ONLY FOR CLINICAL TESTING Battery charger care Every day ⢠Check your battery charger is clean. If you notice any dust or dirt: 1. Disconnect the battery charger from the power source and remove any battery modules. 2. Hold the battery charger upside down and tap it gently to remove any dirt from the battery charger sockets. Carefully blowing on the sockets may also help remove dirt. 3. Wipe the battery charger sockets with a soft dry cloth. ⢠(Y Battery Charger) Use a different charger socket each time you charge to wear the sockets evenly. If it gets wet ⢠If the battery charger ever gets splashed with liquid, carefully shake out the liquid and dry the battery charger for 24 hours. Do not use the battery charger until it is dry. 40 592753_1-06_EN_CP1000_UG_EMEA.indd 40 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:50 PM DRAFT ONLY FOR CLINICAL TESTING Storage Dry aid kit Store your processor at night in the dry aid kit provided by Cochlear. Store the processor fully assembled for 8 hours for optimal drying effect. Storage case CARE For long term storage: ⢠remove disposable batteries and store so they do not touch each other ⢠remove rechargeable battery modules and store fully charged. Storage cases are available from Cochlear. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 41 41 14/06/2016 1:23:51 PM DRAFT ONLY FOR CLINICAL TESTING Water, sand and dirt Your processor is resistant to water, sand and dust. However, it is still a precision electronic device so you should take the following precautions. If your processor ever gets wet, dry it with a soft cloth. Then remove the battery module (and disposable batteries if used), dry them and the contacts with a soft cloth, and replace them. Replace the microphone protectors and place your processor in the dry aid kit provided by Cochlear for 8 hours. See Batteries on page 4. See Change microphone cover on page 44. If sand or dirt ever enter the processor, shake the components carefully to remove it. 42 592753_1-06_EN_CP1000_UG_EMEA.indd 42 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:53 PM DRAFT ONLY FOR CLINICAL TESTING Your processor is protected against failure from dust and temporary immersion in water (IP57 rated) when you wear it with: ⢠a rechargeable battery module ⢠a coil and coil cable ⢠no acoustic component. ⢠a disposable battery module ⢠a coil and coil cable ⢠an acoustic component worn in the ear. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 43 CARE Your processor is protected against failure from splashing water or access of foreign objects 1.0 mm in diameter or larger (IP44 rated) when you wear it with: 43 14/06/2016 1:23:54 PM DRAFT ONLY FOR CLINICAL TESTING Change microphone cover Replace your microphone protectors every three months, or if they look dirty or you notice any loss in sound quality. They are built into the Cochlear Nucleus 7 Microphone Cover, which is completely replaced. Microphone protectors Microphone cover Step 1: Remove old microphone cover 1. Hold the coil cable grip and firmly pull it straight out of the processor. Do not tug on the flexible part of the coil cable. CAUTION Do not twist the coil cable when you pull it out of the processor. 2. Lift the microphone cover from the bottom edge, then lift it up to remove. 44 592753_1-06_EN_CP1000_UG_EMEA.indd 44 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:55 PM DRAFT ONLY FOR CLINICAL TESTING Step 2: Insert new microphone cover 1. Fit the replacement microphone cover onto the processor. 2. Press down firmly with a finger on each end of the microphone cover until you hear a click. CARE 3. Push your coil cable into the processor until it clicks. Do not twist. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 45 45 14/06/2016 1:23:55 PM DRAFT ONLY FOR CLINICAL TESTING Change the coil and cable The Cochlear Nucleus 7 Slimline⢠Coil comes in four cable lengths (6, 8, 11 and 25 cm) so you can choose the most comfortable fit. You might also need to change to a different length cable to use some retention accessories (e.g. Headworn). NOTE Only remove the coil from your sound processor when necessary. 1. Hold the coil cable grip and firmly pull it straight out of the processor. Do not pull on the flexible part of the coil cable. CAUTION Do not twist the coil cable when you pull it out of the processor. 2. Push the new coil cable into the processor until it clicks into place. Do not twist. See Processors and parts on page 64. 46 592753_1-06_EN_CP1000_UG_EMEA.indd 46 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:56 PM DRAFT ONLY FOR CLINICAL TESTING Change the coil magnet You need to choose a Cochlear Nucleus 7 Magnet that is the correct strengthâif it is too weak the coil may fall off, and if it is too strong it may cause discomfort. Magnet strength ranges from ½ (weakest) to 6 (strongest). You might also need to change to a stronger magnet to use some retention accessories (e.g. Headworn). NOTE If your clinician has provided you with a Nucleus 7 Magnet Reverse Polarity, use it as described here for a normal magnet. 1. With finger grips facing up, unscrew the magnet anticlockwise. 2. Remove the magnet. CARE 3. Insert the new magnet and turn clockwise until it stops. 4. To use the tamper-proof lock, turn the magnet a little more until you feel a click. TIP The tamper-proof lock marker aligns with the coil cable when locked. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 47 47 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING Lights Your clinician can set up your processor to show some or all of the following light indications. Turning on and off LIGHT WHAT IT MEANS ⌠Quick green flashes Processor flashes while receiving sound from microphones (Child mode only). Turning on and changing programs. Number of flashes indicates the number of the current program. Quick green flashes Turning off processor. Long flash of orange Locking button LIGHT WHAT IT MEANS Locking processor button. Green flash followed by orange Unlocking processor button. Orange flash followed by green Processor button is locked. Orange flash when pressing button 48 592753_1-06_EN_CP1000_UG_EMEA.indd 48 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING Streaming audio LIGHT Quick blue flash ⌠Quick blue flashes WHAT IT MEANS Processor flashes when pairing to wireless accessory is successful. Processor flashes while receiving audio from an audio source (Child mode only). Alerts WHAT IT MEANS ⌠Flash of orange every second Processor flashes while it is off your head (or connected to the wrong implant). Orange flashes Steady orange Processor batteries are low. Change batteries. Fault. Contact your clinician. Stays on until the issue is resolved. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 49 LIGHTS AND BEEPS LIGHT 49 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING Battery charging LIGHT WHAT IT MEANS ⌠Battery module is charging. Battery module is fully charged. ⌠Error. Try a different rechargeable battery module. If you are using the Y Battery Charger, try the rechargeable battery module on the other connector on the charger. Does not light up 50 592753_1-06_EN_CP1000_UG_EMEA.indd 50 Battery module is not properly connected, is over-discharged, or there is no power. Check the battery charger is properly connected to a power source. Try a different rechargeable battery module NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING Beeps Your clinician can set up your processor so you can hear the following beeps (they are only audible to you). Turning on and off BEEP WHAT IT MEANS Changing the program. The number of beeps indicates the number of the selected program. Short high beeps Short high beep When changing volume or sensitivity, indicates upper or lower limit of volume/ sensitivity reached. LIGHTS AND BEEPS Short high then short low beep Changing volume or sensitivity level (if available). Locking button BEEP Short low beep when you press button Short high then short low beep Short low then short high beep WHAT IT MEANS Processor button is locked. Locking processor button. Unlocking processor button. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 51 51 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING Telecoil BEEP WHAT IT MEANS Switching between using the microphones and the telecoil. Long high beep Wireless accessories BEEP 3-tone chime WHAT IT MEANS Connecting with wireless accessory to begin streaming audio. When stopping streaming. Short beep Alerts BEEP WHAT IT MEANS Processor batteries are low. Change batteries. 2 Short low beeps Short low beeps for 4 seconds 4 long low beeps over 4 seconds 52 592753_1-06_EN_CP1000_UG_EMEA.indd 52 Batteries are empty and processor is turning off. Change batteries. General fault. Consult your clinician. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING Adjusting master volume, bass and treble * BEEP Loud medium beep WHAT IT MEANS Adjusting master volume level. Adjusting treble level. Loud long high beep Adjusting bass level. Loud long low beep LIGHTS AND BEEPS * If available, Nucleus Smart app only NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 53 53 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING Troubleshoot Contact your clinician if you have any concerns regarding the operation or safety of your sound processor. PROBLEM RESOLUTION Processor will not 1. turn on/button will not respond 2. 3. 4. 5. 6. The processor switches off 1. 2. The processor will not turn off 1. 2. 54 592753_1-06_EN_CP1000_UG_EMEA.indd 54 Try turning the processor on again. See Turn on and off on page 18. Try unlocking the button. See Lock the control button on page 19. Change the batteries. See Replace the battery module on page 8 or Change disposable batteries on page 10. If you have two implants, check that you are wearing the correct sound processor on each implant. Check the battery contacts are free of dirt and dust. See Water, sand and dirt on page 42. If the problem continues, contact your clinician. Ask your clinician if âAuto power offâ is enabled. If it is, then the processor will switch off after two minutes when not connected to the implant. Change the batteries. See Replace the battery module on page 8 or Change disposable batteries on page 10. Check the processor is not locked. See Lock the control button on page 19. Remove the battery module from the processing unit. See Remove the battery module on page 8. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING PROBLEM RESOLUTION You are not sure what processor beeps or light flashes mean See Lights on page 48 and Beeps on page 51. You do not hear sound or sound is intermittent 1. 2. 3. 4. 5. You hear 1. intermittent sound, a buzzing sound or distorted speech 2. 3. Check for sources of interference such as radio and TV transmission towers (within approximately 1.6 km or 1 mile), shopping centres, airport security systems and mobile phones. Try moving away from any source of magnetic or electronic interference. If the problem continues, contact your clinician. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 55 TROUBLESHOOT 6. If you use the Nucleus 7 Remote Control, turn up the volume. If you use the Nucleus Smart app, turn up the volume or sensitivity. Try a different program. See Change program on page 20. Change the batteries. See Replace the battery module on page 8 or Change disposable batteries on page 10. Make sure the coil cable is fully inserted into the socket on the processor If the problem continues, contact your clinician. 55 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING PROBLEM RESOLUTION Sound is too loud or uncomfortable 1. 2. 3. 4. 5. Sound is too quiet or muffled 1. 2. 3. 4. 5. 56 592753_1-06_EN_CP1000_UG_EMEA.indd 56 If you use a Nucleus 7 Remote Control, turn down the volume. If you use the Nucleus Smart app, turn down the volume or sensitivity. Try a different program. See Change program on page 20. If you have two sound processors (one for each side), ensure you have them on the correct side. If the problem continues, remove the processor and coil from your head immediately and contact your clinician. If you use a Nucleus 7 Remote Control, turn up the volume. If you use the Nucleus Smart app, turn up the volume or sensitivity. Try a different program. See Change program on page 20. Try changing the microphone protectors. See Change microphone cover on page 44. If the problem continues, contact your clinician. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING PROBLEM RESOLUTION You want to confirm your processor is receiving sound 1. 2. 3. 4. Check the light on the top of the processor (if enabled). See Lights on page 48. If you have monitor earphones, a hearing person can listen to the sound received by the processor. See Use monitor earphones on page 24. If you use the Nucleus Smart app, use the sound meter to check the processor is receiving sound ????. If the problem continues, contact your clinician. 1. Remove the processor and coil from your head immediately and contact your clinician. You experience tightness, discomfort or develop a skin irritation at your implant site 1. Your coil magnet may be too strong or in contact with your skin. Change to a weaker magnet. See Change the coil magnet on page 47. If you are using a retention aid, such as a headband, this may be placing pressure on your processor. Adjust your retention aid, or try a different aid. If the problem continues, contact your clinician. 2. 3. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 57 TROUBLESHOOT The processor or coil become hot 57 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING PROBLEM RESOLUTION You do not hear 1. sound from a wireless accessory 2. 3. 4. 5. 6. 7. You do not hear sound from a monitor earphone 1. 2. 3. 4. 58 592753_1-06_EN_CP1000_UG_EMEA.indd 58 Check that the wireless accessory is charged and turned on. Check that the wireless accessory is paired with your processor. Check the volume of the wireless accessory. If you use the Nucleus Smart app, use the sound meter to check the processor is receiving sound from the accessory. If you use the Nucleus Smart app, check and adjust the accessory/microphone mixing ratio. If available, try a different processor. For more troubleshooting, see the True Wireless Accessory User Guide. Check that the monitor earphone cable is fully inserted into the socket on the processing unit. Check that the monitor earphone adaptor is properly connected to the processor and battery module. If you use the Nucleus Smart app, use the sound meter to check the processor volume level. If available, try a different processor. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING PROBLEM RESOLUTION You hear loud or distorted sound from a monitor earphone 1. The processor gets 1. wet You want to perform a regular check on your processor Remove the monitor earphone and consult your clinician. Dry the processor with a soft cloth, change the microphone protectors and place the processor in the dry aid kit provided by Cochlear for 8 hours. See Water, sand and dirt on page 42. See Regular care on page 38. TROUBLESHOOT NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 59 59 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING PROBLEM RESOLUTION Batteries are not lasting as long as usual 1. 2. 3. 4. 5. 6. Clean all connections and parts of the battery module. Clean all connections on the processing unit. Try replacing the coil with a new coil. If you are using disposable batteries, check that you are using the recommended batteries. See Change disposable batteries on page 10. Donât forget to let new disposable batteries stand for a few seconds before you put them in the sound processor. If the problem continues, contact your clinician. The indicator light This wonât cause any damage to the battery on the battery as the charge cycle on a fully charged battery charger shows a is very short. fully charged battery is still charging The indicator light 1. on the battery charger is flashing orange 2. 60 592753_1-06_EN_CP1000_UG_EMEA.indd 60 Check that only rechargeable battery modules are connected to the battery charger. Replace the rechargeable battery module. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:58 PM DRAFT ONLY FOR CLINICAL TESTING Cautions ⢠Young children who are developing motor skills are at greater risk of an impact to the head from a hard object (e.g. table or chair). Impact to the sound processor may cause damage to the processor or its parts. Impact to the head in the area of the Cochlear implant could damage it and result in its failure. ⢠Most patients can benefit from electrical stimulation levels that are considered safe, based on animal experimental data. The long-term effects of such stimulation in humans are unknown. CAUTIONS NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 61 61 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Warnings For parents and carers ⢠Removable parts of the system (e.g. microphone cover, magnets, batteries, battery cover, retention aids) can be lost or may be a choking or strangulation hazard. Keep out of reach of children or lock the tamper-resistant screw on the battery module and/or cover. ⢠Parents and carers are advised that unsupervised use of long cables (e.g. coil or accessory cables) may present a risk of strangulation. ⢠Sound processor covers may not be suitable for children. Removable parts can be lost or may be a choking hazard. ⢠Carers must routinely check the device for signs of overheating and for signs of discomfort or skin irritation at the implant site. Remove the processor and coil immediately if there is any discomfort or pain (e.g. if device becomes hot, or sound is uncomfortably loud) and contact your clinician. 62 592753_1-06_EN_CP1000_UG_EMEA.indd 62 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING ⢠Carers must monitor for signs of discomfort or skin irritation if a retention aid (e.g. headband) is used that applies pressure to the sound processor or coil. Remove the aid immediately if there is any discomfort or pain, and contact your clinician. ⢠Keep the dry brick from the dry aid kit away from small children. Swallowing this material can cause serious internal injuries. ⢠Do not allow children to replace batteries without adult supervision. ⢠Do not allow children to use a battery charger without adult supervision. WARNINGS NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 63 63 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Processors and parts ⢠Each processor is programmed specifically for each implant. Never wear another personâs processor or lend yours to another person. ⢠Use your Cochlear implant system only with approved devices and accessories. ⢠If you experience a significant change in performance, remove your processor and contact your clinician. ⢠Your processor and other parts of the system contain complex electronic parts. These parts are durable but must be treated with care. ⢠No modification of this equipment is allowed. Warranty will be void if modified. ⢠Remove the monitor earphones immediately if the sound level is uncomfortably loud and inform your clinician. ⢠If the coil magnet is too strong or is in contact with the skin, pressure sores may develop at the implant site. If this happens, or if you experience tightness or pain in this area, stop using your sound processor and contact your clinician. ⢠Do not apply continued pressure to the coil when in contact with the skin (e.g. sleeping while lying on coil, or using tight fitting headwear). ⢠Do not push the volume too high for comfort in case a loud noise occurs nearby. 64 592753_1-06_EN_CP1000_UG_EMEA.indd 64 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 65 WARNINGS ⢠If you need to adjust the volume often, or if adjusting volume ever causes discomfort, contact your clinician. ⢠Do not let your processor or parts entangle with any jewellery (e.g. earhook and earrings) or machinery. ⢠Do not place the processor or parts in any household devices (e.g. microwave oven, dryer). ⢠Do not expose the processor or parts to heat (e.g. never leave them in sunlight, behind a window or in a car). ⢠Do not use a dry aid kit that has an Ultra Violet C (UVC) lamp (e.g. do not use the Freedom⢠Dry and Store). ⢠The magnetic attachment of your sound processor to your implant may be affected by other magnetic sources. ⢠Store spare coil magnets safely and away from cards that may have a magnetic strip (e.g. credit cards, bus tickets). ⢠Your device contains magnets that should be kept away from life supporting devices (e.g. cardiac pacemakers and ICDs (implantable cardioverter defibrillators) and magnetic ventricular shunts), as the magnets may affect the function of these devices. Keep your processor at least 15 cm (6 in) from such devices. Contact the manufacturer of the specific device to find out more. ⢠Your sound processor and remote control radiate electromagnetic energy that may interfere with life supporting devices, (e.g. cardiac pacemakers and ICDs). Keep your processor and remote control at least 15 cm (6 in) from such devices. Contact the manufacturer of the specific device to find out more. 65 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING ⢠Do not place the device or accessories inside any part of your body (e.g. nose, mouth). ⢠Seek medical advice before entering any environment that may adversely affect the operation of your Cochlear implant, including areas protected by a warning notice preventing entry by patients fitted with a pacemaker. ⢠Some types of digital mobile telephones (e.g. Global System for Mobile communications (GSM) as used in some countries) may interfere with the operation of your external equipment. You may hear distorted sound when close, 1-4 m (~3-12 ft), to a digital mobile telephone in use. ⢠For Cochlear Nucleus cochlear implant recipients only, the maximum diving depth is 40 m (~131 ft). Seek medical advice before diving to ensure you do not have any conditions that might make diving contraindicated (e.g. middle ear infection). When wearing a mask, avoid pressure over the implant site. ⢠Before activities that create electrostatic discharge (e.g. playing on plastic slides), remove your processor. In rare cases, discharge of static electricity can damage your Cochlear implantâs electrical components or corrupt the processorâs program. If static electricity is present (e.g. when putting on clothes over your head, or getting out of a car), before the Cochlear implant system touches any object or person, you should touch something conductive such as a metal door handle. 66 592753_1-06_EN_CP1000_UG_EMEA.indd 66 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Batteries NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 67 WARNINGS ⢠Use only Cochlear supplied or recommended 675 (PR44) zinc air batteries designed for cochlear implant use. We do not recommend using silver oxide or alkaline batteries. ⢠Insert disposable batteries in the correct orientation. ⢠If disposable batteries are short-circuited the processor will not work and its temperature can reach 42° C (107° F). Remove the processor and coil immediately and contact your clinician. ⢠Do not mix disposable batteries that differ by manufacturer, brand, type, age or previous usage. ⢠Replace both disposable batteries at the same time. ⢠Dispose of used batteries promptly and carefully, in accordance with local regulations. Keep away from children. ⢠Do not short-circuit batteries (e.g. do not let terminals of batteries contact each other, do not place batteries loose in pockets, etc.). ⢠Do not disassemble, deform, immerse in water or dispose of batteries in fire. ⢠When processor is not in use, remove the batteries and store separately in a clean and dry place. 67 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING ⢠Wipe batteries with a clean dry cloth if they become dirty. ⢠Store unused batteries in original packaging, in a clean and dry place. ⢠Do not use damaged or deformed batteries. If skin or eyes come into contact with battery fluid or liquid, wash out with water and seek medical attention immediately. ⢠Do not expose batteries to heat (e.g. never leave batteries in sunlight, behind a window or in a car). ⢠Never put batteries in your mouth. If swallowed, contact your physician or local poison information service. ⢠Do not recharge disposable batteries. ⢠Only use rechargeable batteries and battery chargers supplied or recommended by Cochlear. Use of other batteries or battery chargers may result in harm or injury. ⢠Charge rechargeable batteries before use. ⢠Do not touch the battery charger contacts. 68 592753_1-06_EN_CP1000_UG_EMEA.indd 68 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Medical treatments Magnetic resonance imaging (MRI) MRI is contraindicated except under special circumstances. Do not allow a patient with an implant to be in a room where an MRI scanner is located except under special circumstances. Full MRI safety information is available at www.cochlear.com/warnings or by calling your regional Cochlear office (contact numbers available at the end of this document). If the patient is implanted with other implants, consult the manufacturerâs instructions before performing MRI. WARNINGS NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 69 69 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Medical treatments generating induced currents, heat and vibration Having a cochlear implant means extra care must be taken when receiving some medical treatments. Before starting medical treatment, the information in this section should be discussed with the recipientâs physician. The sound processor must be removed before starting any of the medical treatments listed in this section. Some medical treatments generate induced currents that may cause tissue damage or permanent damage to the implant. Before initiating any of the following treatments deactivate the device. Warnings for specific treatments are provided below. CONDITION WARNING Diathermy Do not use therapeutic or medical diathermy (thermopenetration) using electromagnetic radiation (magnetic induction coils or microwave). High currents induced into the electrode lead can cause tissue damage to the cochlea/brainstem or permanent damage to the implant. Medical diathermy using ultrasound may be used below the head and neck. Electroconvulsive Do not use electroconvulsive therapy on an implant therapy patient under any circumstances. Electroconvulsive therapy can cause tissue damage or damage to the implant. 70 592753_1-06_EN_CP1000_UG_EMEA.indd 70 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING CONDITION WARNING Electrosurgery Electrosurgical instruments can induce radio frequency currents that could flow through the electrode. Monopolar electrosurgical instruments must not be used on the head or neck of an implant patient as induced currents could cause damage to cochlear/ neural tissues or permanent damage to the implant. When using bipolar electrosurgical instruments on the head and neck of a patient, the cautery electrodes must not contact the implant and should be kept more than 1 cm (½ in.) from the electrodes. Ionising radiation Do not use ionising radiation therapy directly over the therapy implant. It may cause damage to the implant. Neurostimulation Do not use neurostimulation directly over the implant. High currents induced into the electrode lead can cause tissue damage to the cochlea/brainstem or permanent damage to the implant Do not use therapeutic levels of ultrasound energy directly over the implant. It may inadvertently concentrate the ultrasound field and cause tissue damage or damage to the implant. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 71 WARNINGS Therapeutic ultrasound 71 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Other information Physical configuration The processing unit comprises: ⢠Two omni-directional microphones for receiving sound. ⢠An internal telecoil for receiving magnetic fields radiated by phones, neckloops and roomloops. ⢠Custom analogue and digital integrated circuits with digital signal processing (DSP) and bidirectional wireless communication capabilities. ⢠A tri-colour visual indication of processor function or problem. ⢠Control button allowing user control of key features. ⢠Custom 4-pin connector for coil cable. ⢠A range of earhooks and specialised retention options. The batteries provide power to the processor. The coil acts as a transformer coupling that transfers energy and data to the implant. 72 592753_1-06_EN_CP1000_UG_EMEA.indd 72 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Materials Battery life, charge cycles and lifespan ⢠Battery life means the time a device will run before the disposable batteries must be replaced, or the rechargeable batteries recharged. ⢠Battery charge cycle is a full charge and discharge of the rechargeable battery. ⢠Battery lifespan means the total number of charge cycles a rechargeable battery will last before the battery life degrades to 80% of its original fully-charged capacity. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 73 OTHER INFORMATION ⢠Processing unit: copolyester. ⢠Battery modules (all types) are made of copolyester. ⢠Coil is made of polypropylene (PP), thermoplastic elastomer (TPE). ⢠Coil magnet casing is made of acrylonitrile butadiene styrene (ABS). ⢠Coil cable sheath is made of polyvinyl chloride (PVC). ⢠Coil cable plugs are made of PP and TPE. ⢠Retention parts are made from polyamide (PA) and liquid silicone rubber (LSR). 73 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Operating characteristics Processing unit CHARACTERISTIC VALUE/RANGE Sound input frequency range 100 Hz to 8 kHz Wireless technology Proprietary low power bidirectional wireless link RF frequency 2.4 GHz Operating voltage 2.00 V to 4.25 V Power consumption 20 mW to 100 mW Charge cycles ⼠80% capacity after 400 charge/ discharge cycles at room temperature Button functions Turn processor on and off, turn audio streaming on and off, change program Remote communication range Up to 2 m Battery module TYPE CAPACITY/VOLTAGE RANGE Disposable battery module Two PR44 (zinc air) button cell batteries. 1.45 V (nominal) each. Cochlear recommends 675 zinc air batteries designed for cochlear implant use. Compact rechargeable 91 mAh / 3.7 V battery module Standard rechargeable 183 mAh / 3.7 V battery module Coil CHARACTERISTIC VALUE/RANGE Operating voltage 2.0 V to 2.6 V Operating frequency 5 MHz 74 592753_1-06_EN_CP1000_UG_EMEA.indd 74 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Product component dimensions (Typical values) ITEM LENGTH WIDTH DEPTH DIAMETER Nucleus 7 processing unit with medium earhook and standard rechargeable battery module 36.5 mm 9.0 mm 45.0 mm N/A 9.0 mm 17.3 mm N/A 17.8 mm N/A Disposable battery module 29.4 mm Compact rechargeable battery module 18.0 mm 9.0 mm Standard rechargeable battery module 9.0 mm 17.8 mm N/A N/A N/A 5.8 mm 30.3 mm OTHER INFORMATION Coil 24.8 mm Product weight (Typical values. All weights are measured with a medium earhook.) COMPONENT WEIGHT Nucleus 7 processing unit (no battery module) 3.9g Nucleus 7 processing unit with compact rechargeable battery module 7.8g Nucleus 7 processing unit with standard rechargeable battery module 9.8g Nucleus 7 processing unit with disposable battery module (including two 675 zinc air batteries) 10.1g Coil and cable (without coil magnet) 3.9g NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 75 75 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Environmental conditions CONDITION MINIMUM MAXIMUM Storage & transport temperature -10° C (14° F) +55° C (131° F) Storage & transport humidity 0% RH 90% RH Operating temperature (sound processor)+5° C (41° F) +40° C (104° F) Operating temperature (battery charger) +0° C (32° F) +40° C (104° F) Operating relative humidity 0% RH 90% RH Operating pressure 700 hPa 1060 hPa Environmental protection Your sound processor contains electronic components subject to the Directive 2002/96/EC on waste electrical and electronic equipment. Help protect the environment by not disposing of your sound processor or batteries with your unsorted household waste. Please recycle your sound processor according to your local regulations. Equipment classification Your sound processor is internally powered equipment Type B applied part as described in the international standard IEC 60601-1:2012, Medical Electrical EquipmentâPart 1: General Requirements for Basic Safety and Essential Performance. 76 592753_1-06_EN_CP1000_UG_EMEA.indd 76 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Disposable batteries Check the battery manufacturerâs recommended operating conditions for disposable batteries used in your processor. Wireless communication link The wireless communication link operates in the 2.4 GHz ISM band using GFSK (Gaussian frequency-shift keying), and a proprietary bidirectional communication protocol. It continuously switches between channels to avoid interference on any specific channel. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 77 OTHER INFORMATION ⢠The remote control operates over 4 channels, over a distance of up to 2 metres from the processor. It indicates via its display when the processor is out of operating distance (or switched off) or when the link is interrupted due to broad spectrum interference (see remoteâs user guide for more information). ⢠The True Wireless accessories operate over 16 channels, over a distance of up to 3 metres for the Phone Clip, and 7 metres for the Mini Microphone and TV Streamer. Bluetooth Smart also operates in the 2.4 GHz ISM band, using Frequency Hopping Spread Spectrum (FHSS) to combat interference. Operating range is up to 7 metres, and the app indicates when the processor is out of operating distance (or switched off) or when the link is interrupted due to broad spectrum interference. 77 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Electromagnetic compatiblity (EMC) WARNING Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 in.) to any part of your Nuclues 7 Sound Processor, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result. Interference may occur in the vicinity of equipment marked with the following symbol: FCC (Federal Communications Commission) and Canadian IC compliance This device complies with part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: ⢠This device may not cause harmful interference. ⢠This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this equipment not expressly approved by Cochlear Limited may void the FCC authorisation to operate this equipment. 78 592753_1-06_EN_CP1000_UG_EMEA.indd 78 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: FCCID:WTOCP1000 IC ID: 8039A-CP1000 CAN ICES-3 (B)/NMB-3(B) NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 79 OTHER INFORMATION ⢠Reorient or relocate the receiving antenna. ⢠Increase the separation between the equipment and receiver. ⢠Connect the equipment into an outlet or a circuit different from that to which the receiver is connected. ⢠Consult the dealer or an experienced radio/TV technician for help. 79 14/06/2016 1:23:59 PM DRAFT ONLY FOR CLINICAL TESTING Radio compliance for Japan This device is granted pursuant to the Japanese Radio Law ) and its relevant law. This device should not be modified (otherwise the granted designation number will become invalid). R 202-L SD 08 8 Radio compliance for Korea 1. Equipment name/model name: 2. Registration number: MSIP-CRM-COH-CP1000 3. Company name: Cochlear Limited 4. Manufactured date: 2016 5. Manufacturer/Country of Origin: Cochlear Limited/Australia WARNING This radio equipment has the possibility of radio interference during operation. This equipment is suitable for electromagnetic equipment for home (Class B) and it can be used in all areas. 80 592753_1-06_EN_CP1000_UG_EMEA.indd 80 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:24:00 PM DRAFT ONLY FOR CLINICAL TESTING Certification and applied standards The Nucleus 7 Sound Processor fulfils the essential requirements listed in Annex 1 of the EC directive 90/385/EEC on Active Implantable Medical Devices as per the conformity assessment procedure in Annex 2. The year in which authorisation to affix the CE mark was granted was 2016. The Nucleus 7 Sound Processor also fulfils the essential requirements listed in the EC directive 1999/5/EC on Radio and Terminal Telecommunication Equipment as per the conformity assessment procedure in Annex IV. OTHER INFORMATION NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 81 81 14/06/2016 1:24:00 PM DRAFT ONLY FOR CLINICAL TESTING Labelling symbols The following symbols may appear on your processor or remote components and/or packaging: Refer to instruction manual Specific warnings or precautions associated with the device, which are not otherwise found on the label Manufacturer M/N Model number Authorised representative in the European Community Catalogue number Serial number Batch code Date of manufacture Temperature limits CE registration mark with notified body number Radio compliance certification for Australia and New Zealand 82 592753_1-06_EN_CP1000_UG_EMEA.indd 82 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:24:01 PM DRAFT ONLY FOR CLINICAL TESTING R 202-L SD0 8 8 Radio compliance certification for Japan Radio compliance certification for Korea By prescription Recyclable material OTHER INFORMATION Dispose of electrical components in accordance with your local regulations Type B applied part Ingress Protection Rating ⢠Protected against access of solid foreign objects greater than or equal to 1.0mm diameter. ⢠Protected against failure from splashing water. Ingress Protection Rating ⢠Protected against access of solid foreign objects greater than or equal to 1.0mm diameter. ⢠Protected against failure from dust penetration. ⢠Protected against failure from temporary immersion in water. NUCLEUS 7 SOUND PROCESSOR USER GUIDE 592753_1-06_EN_CP1000_UG_EMEA.indd 83 83 14/06/2016 1:24:02 PM DRAFT ONLY FOR CLINICAL TESTING Privacy and the collection of personal information During the process of receiving a Cochlear device, personal information about the user/recipient or their parent, guardian, carer and hearing health professional will be collected for use by Cochlear and others involved in care with regard to the device. For more information please read Cochlearâs Privacy Policy on www.cochlear.com or request a copy from Cochlear at the address nearest you. Legal statement The statements made in this guide are believed to be true and correct as of the date of publication. However, specifications are subject to change without notice. Š Cochlear Limited 2016 84 592753_1-06_EN_CP1000_UG_EMEA.indd 84 NUCLEUS 7 SOUND PROCESSOR USER GUIDE 14/06/2016 1:24:02 PM Notes .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... .................................................................................................................... 592753_1-06_EN_CP1000_UG_EMEA.indd 85 14/06/2016 1:24:02 PM DRAFT ONLY FOR CLINICAL TESTING Cochlear Ltd (ABN 96 002 618 073) 1 University Avenue, Macquarie University, NSW 2109, Australia Tel: +61 2 9428 6555 Fax: +61 2 9428 6352 Cochlear Ltd (ABN 96 002 618 073) 14 Mars Road, Lane Cove, NSW 2066, Australia Tel: +61 2 9428 6555 Fax: +61 2 9428 6352 Cochlear Americas 13059 E Peakview Avenue, Centennial, CO 80111, USA Tel: +1 303 790 9010 Fax: +1 303 792 9025 Cochlear Canada Inc 2500-120 Adelaide Street West, Toronto, ON M5H 1T1, Canada Tel: +1 416 972 5082 Fax: +1 416 972 5083 Cochlear AG EMEA Headquarters, Peter Merian-Weg 4, 4052 Basel, Switzerland Tel: +41 61 205 8204 Fax: +41 61 205 8205 Cochlear Deutschland GmbH & Co. KG Karl-Wiechert-Allee 76A, 30625 Hannover, Germany Tel: +49 511 542 770 Fax: +49 511 542 7770 Cochlear Europe Ltd 6 Dashwood Lang Road, Bourne Business Park, Addlestone, Surrey KT15 2HJ, United Kingdom Tel: +44 1932 26 3400 Fax: +44 1932 26 3426 Cochlear Benelux NV SchaliĂŤnhoevedreef 20 i, B-2800 Mechelen, Belgium Tel: +32 15 79 55 11 Fax: +32 15 79 55 70 Cochlear France S.A.S. 135 Route de Saint-Simon, 31035 Toulouse, France Tel: +33 5 34 63 85 85 (International) or 0805 200 016 (National) Fax: +33 5 34 63 85 80 Cochlear Italia S.r.l. Via Larga 33, 40138 Bologna, Italy Tel: +39 051 601 53 11 Fax: +39 051 39 20 62 Cochlear Nordic AB Konstruktionsvägen 14, 435 33 MĂślnlycke, Sweden Tel +46 31 335 14 61 Fax +46 31 335 14 60 Cochlear TÄąbbi Cihazlar ve SaÄlÄąk Hizmetleri Ltd. Ĺti. Ăubuklu Mah. BoÄaziçi Cad., BoÄaziçi Plaza No: 6/1, KavacÄąk, TR-34805 Beykoz-Istanbul, Turkey Tel: +90 216 538 5900 Fax: +90 216 538 5919 Cochlear (HK) Limited Room 1204, 12/F, CRE Building, No 303 Hennessy Road, Wanchai, Hong Kong SAR Tel: +852 2530 5773 Fax: +852 2530 5183 Cochlear Korea Ltd 1st ďŹoor, Cheongwon Building 33, Teheran-ro 8 gil, Gangnam-gu, Seoul, Korea Tel: +82 2 533 4450 Fax: +82 2 533 8408 Cochlear Medical Device (Beijing) Co., Ltd Unit 2208 Gemdale Tower B, 91 Jianguo Road, Chaoyang District, Beijing 100022, P.R. China Tel: +86 10 5909 7800 Fax: +86 10 5909 7900 Cochlear Medical Device Company India Pvt. Ltd. Ground Floor, Platina Building, Plot No C-59, G-Block, Bandra Kurla Complex, Bandra (E), Mumbai â 400 051, India Tel: +91 22 6112 1111 Fax: +91 22 6112 1100 ć Şĺźäźç¤žćĽćŹăłăŻăŹă˘ ďźNihon Cochlear Co Ltdďź ă113-0033 ćąäşŹé˝ć亏ĺşćŹéˇ2-3-7 ăčśăŽć°´ĺ çşă㍠Tel: +81 3 3817 0241 Fax: +81 3 3817 0245 Cochlear Middle East FZ-LLC Dubai Healthcare City, Al Razi Building 64, Block A, Ground Floor, OfďŹces IR1 and IR2, Dubai, United Arab Emirates Tel: +971 4 818 4400 Fax: +971 4 361 8925 Cochlear LatinoamĂŠrica S.A. International Business Park, Building 3835, OfďŹce 403, Panama PaciďŹco, Panama Tel: +507 830 6220 Fax: +507 830 6218 Cochlear NZ Limited Level 4, Takapuna Towers, 19-21 Como St, Takapuna, Auckland 0622, New Zealand Tel: + 64 9 914 1983 Fax: 0800 886 036 www.cochlear.com ACE, Advance Off-Stylet, AOS, AutoNRT, Autosensitivity, Beam, Button, Carina, Cochlear, ăłăŻăŹă˘, Codacs, Contour, Contour Advance, Custom Sound, ESPrit, Freedom, Hear now. And always, Hugfit, Hybrid, inHear, Invisible Hearing, Kanso, MET, MP3000, myCochlear, NRT, Nucleus, ç§ĺŠčł, Off-Stylet, Slimline, SmartSound, Softip, SoftWear, SPrint, True Wireless, the elliptical logo and Whisper are either trademarks or registered trademarks of Cochlear Limited. Ardium, Baha, Baha SoftWear, BCDrive, DermaLock, EveryWear, Vistafix and WindShield are either trademarks or registered trademarks of Cochlear Bone Anchored Solutions AB. Bluetooth is a registered trademark of Bluetooth SIG. iPhone and iPod touch are tradmarks of Apple Inc, registered in the U.S. and other countries. Š Cochlear Limited 2016 592753 ISS1 MAY16 592753_1-06_EN_CP1000_UG_EMEA.indd 86 14/06/2016 1:24:03 PM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 88 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:6f091ebb-7bf1-11e6-0000-03cf18f26d54 Producer : GPL Ghostscript 9.10 Keywords : () Modify Date : 2016:09:13 11:38:27+02:00 Create Date : 2016:09:13 11:38:27+02:00 Creator Tool : PDFCreator Version 1.7.2 Document ID : uuid:6f091ebb-7bf1-11e6-0000-03cf18f26d54 Format : application/pdf Title : CP1000_User manual-592753_1-06_EN_CP1000_UG_EMEA_hr.pdf Creator : lvp Description : () Author : lvp Subject :EXIF Metadata provided by EXIF.tools