Coen Consultant VDUL5NA Modular transmitter User Manual DC install guide v1 12

Coencorp Consultant Corporation Modular transmitter DC install guide v1 12

Contents

Installation Guide

Download: Coen Consultant VDUL5NA Modular transmitter User Manual DC install guide v1 12
Mirror Download [FCC.gov]Coen Consultant VDUL5NA Modular transmitter User Manual DC install guide v1 12
Document ID1123241
Application IDLj263a22tTEvNAS16i7VVw==
Document DescriptionInstallation Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize16.98kB (212289 bits)
Date Submitted2009-06-11 00:00:00
Date Available2009-06-11 00:00:00
Creation Date2009-05-29 10:00:11
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2009-05-29 10:00:11
Document TitleMicrosoft Word - DC install guide v1.12.doc
Document CreatorPScript5.dll Version 5.2
Document Author: sandyv

8 Place du Commerce, suite 100,
Tel: 1-450-672-4222
Brossard QC Canada J4W 3H2
Toll free (US & Canada):
1-866-COENCORP
http://www.coencorp.com
Fax: 1-450-672-6038
mailto:info@coencorp.com
FleetZone
Data Collector
Installation Guide
Created on: 5/29/2009 9:59 AM
Created by: Serge Kopikov
Document revision: 1.12
Data Collector Installation Guide
revision 1.12
Copyright
This document cannot be redistributed to third party, reproduced or modified
without written permission from Coencorp.
Disclaimer
The information in this document is subject to change without notice. While
the information contained herein is assumed to be accurate, Coencorp
assumes no responsibility for any errors or omissions.
Page 2 of 11
Data Collector Installation Guide
revision 1.12
Table of contents
Introduction ................................................................................................................................................................. 5
Specifications .............................................................................................................................................................. 6
Installing Data Collector.............................................................................................................................................. 7
Connecting Data Collector to a SiteController .......................................................................................................... 10
Page 3 of 11
Data Collector Installation Guide
revision 1.12
The North American versions of RF devices included in this manual contain the board having the
following agency approval numbers:
US/FCC ID
VY3-VDUL5NA
CAN/IC ID
7522A-VDUL5NA
Warning:
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
Warning:
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate
the equipment.
Coencorp is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment.
The devices included in this manual were tested with the following antennae:
Device
Antenna P/N (Coencorp)
FGD-00582-02 (North American ver.)
MOD-00797 with RPSMA
(internally mounted RF antenna)
FGD-00582-03 (European ver.)
Warning: Any antenna not explicitly specified in this manual must be tested to
comply with FCC section 15.203 for unique antenna connectors and
section 15.249 for emissions.
Page 4 of 11
Data Collector Installation Guide
revision 1.12
Introduction
Coencorp RF Data Collector is an RF modem used in Coencorp Fleet and Fuel Management System
to collect data from Vehicle Data Units (VDU) and to assist in the automated fueling sequence.
The RF communication between Data Collector and VDU uses 915 MHz (North American) or 868
MHz (European) frequency bands. The VDU only sends data in response to requests from Data
Collector. The communication has a typical range of 300-600 ft (100-200 m) from the Data
Collector.
The fixed Data Collector is mounted in a standard sealed electrical enclosure suitable for outdoor
use. Besides the standard fixed Data Collector there exists a portable version having the same
hardware and software but packaged in a smaller VDU-like enclosure. The portable version of data
collector may be used for VDU installation tests with a laptop (see the VDU manual for details).
This manual only covers the fixed Data Collector.
The Data Collector communicates with host computer through RS-232 serial port or USB (using
USB-to-Serial adapter).
VDU
VDU
VDU
Site
Controller
RF Data
Collector
VDU
Figure 1. DataZone Site structure
Page 5 of 11
Data Collector Installation Guide
revision 1.12
Specifications
Parameter
FGD-00582-02
(North American version)
FGD-00582-03
(European version)
Electrical
RS-232 baud rate
9600,19200,38400
DC supply voltage
9..25 V
DC supply current, max
30 mA
RF
Radio type
Frequency band
Channels
Channel spacing
Range (typical)
Antenna connector
Antenna
Fixed frequency
910.0..920.0 MHz
868 MHz
11
1.0 MHz
–
100..200 m (300..600 ft)
RP-SMA
MOD-00797
Mechanical & Environmental
Storage temperature
-50..+85 oC
Operating temperature
-20..+55 oC
Dimensions
Interface connector
229 mm x 229 mm x 127 mm (9.0” x 9.0” x 5.0”)
Screw terminal block
Page 6 of 11
Data Collector Installation Guide
revision 1.12
Installing Data Collector
Mounting plate
RF board
Terminal block
RF antenna
A fixed Data Collector connects to a SiteController computer through RS-232 port and does not
require special drivers to be installed on the computer. This section contains mechanical sketches
and electrical wiring diagrams for the installation. The Data Collector is shipped without cables and
connectors: the installer must provide a cable.
Figure 3. Data Collector – internal layout
Page 7 of 11
Data Collector Installation Guide
11.5" (292 mm)
10.5" (267 mm)
9.0" (229 mm)
revision 1.12
9.0" (229 mm)
10.5" (267 mm)
5.0" (127 mm)
11.5" (292 mm)
Figure 2. Data Collector – outside dimensions
Page 8 of 11
Data Collector Installation Guide
revision 1.12
Figure 4. Data Collector mounted on a wall (cover removed)
+12V RET COM TX
RX
Figure 5. Data Collector – terminal block
Page 9 of 11
Data Collector Installation Guide
revision 1.12
Wall plug power supply
9-12 VDC, 0.5A
+Vout
-Vout
COM1
SiteController
DB9-F
100' (30 m) max
RX
TX
COM
RET
12V
Connecting Data Collector to a SiteController
RF Data Collector
Figure 6. Data Collector connection to a SiteController through RS-232
Page 10 of 11
COM
COM
+12V
COM
COM
+12V
+Vout
DB9-M
-Vout
RD(A)
RD(B)
4WSD9OTB
TD(A)
TD(B)
RD(A)
RD(B)
4WSD9OTB
TD(A)
TD(B)
1000' (300 m) max
Wall plug power supply
9-12 VDC, 0.5A
COM1
SiteController
RET
12V
TX
COM
RX
RF Data Collector
Data Collector Installation Guide
revision 1.12
Figure 7. Data Collector connection to a SiteController through RS-422 (extended cable run).
Page 11 of 11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 11
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:e553df55-ce55-42c3-bf9b-4d8f1592c4f3
Producer                        : Acrobat Distiller 6.0 (Windows)
Create Date                     : 2009:05:29 10:00:11-07:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2009:05:29 10:00:11-07:00
Document ID                     : uuid:f97fdda8-e23a-489b-8093-ca60a75f6f87
Format                          : application/pdf
Title                           : Microsoft Word - DC install guide v1.12.doc
Creator                         : sandyv
Author                          : sandyv
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VY3-VDUL5NA

Navigation menu