Hoshizaki
KM-61BAH

Hoshizaki reserves the right to change specifications without notice.

Item #

Project:
Qty:

*AutoCad available on KCL

SELF-CONTAINED CUBER WITH BUILT-IN STORAGE BIN

KM-61BAH
4/08
Item # 13216

CUBER DIMENSIONS
W x D x H

KM-61BAH
173/4 x 24 x 39*
* with 6" legs

KM-61BAH
Air-Cooled
Shown

•
•
•
•
•
•
•
•
•
•
•
•
•

Up to 71 lbs. of ice production per 24 hours
Up to 38 lbs. of built-in storage capacity
Individual crescent cube
Durable stainless steel exterior
CycleSaver® Design

®

EverCheck® alert system
Front in, front out airflow
Stainless steel evaporator
Slide in door
Removable air filter
Power switch accessible without panel removal
Built-in installation possible
R-134a Refrigerant

Warranty

©

HOSHIZAKI AMERICA, INC.

618 Hwy. 74 S., Peachtree City, GA 30269

Valid in United States, Canada, Puerto Rico, & U.S. Territories. Contact factory for warranty in
other countries.
Three Year - Parts & Labor on entire machine.
Five Year - Parts on compressor and air-cooled condenser coil.
Five Year - Parts on evaporator.
TEL 1-800-438-6087

FAX 1-800-345-1325

www.hoshizaki.com

Hoshizaki
KM-61BAH
SELF-CONTAINED CUBER WITH BUILT-IN STORAGE BIN
DIMENSIONS
W x D x H

KM-61BAH
173/4 x 24 x 39*

• Air-cooled

*with 6" legs

Water Temp˚ F.

Air Temp˚ F.

AIR-COOLED

50˚

70˚

71

80˚

KM-61BAH

Ice Production
Per Cycle
Lbs.
Cubes

1.7

S P E C I F I C AT I O N S

Model Number

KM-61BAH

Condenser

Air-Cooled

56

51

58

49

65

UTILITY CONSUMPTION

Model Number

90˚

65

66

90˚

70˚

43

KWH per
100 LBS.

80

10.5

Amperage

3.4

Potable

Water
Gal. per
100 lbs.

20.3

Min. Circuit
Ampacity

15A

Condenser

Water
Gal. per
100 lbs.

N/A

FRONT DIMENSIONS

Shipping
Weight

117 lbs.

KM CUBE DIMENSIONS

SIDE DIMENSIONS

BACK DIMENSIONS
ELECTRICAL & PLUMBING/KM-61BAH
• 115V/60/1
• 15 amp Max Fuse/HACR Breaker Size
• 3/8” OD copper or equivalent independent potable water supply
• 3/4” independent drain connection
• 1/2” FPT Water Inlet

©

HOSHIZAKI AMERICA, INC.

618 Hwy. 74 S., Peachtree City, GA 30269

O P E R AT I N G L I M I T S
• Ambient Temp Range
• Water Temp Range
• Water Pressure
• Voltage Range

TEL 1-800-438-6087

45 - 100˚F
45 - 90˚F
10 - 113psig
104 - 127V

FAX 1-800-345-1325

www.hoshizaki.com

Printed in U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Creator                         : QuarkXPress(R) 7.3
Producer                        : QuarkXPress(R) 7.3
Create Date                     : 2008:04:22 15:16:36
Modify Date                     : 2008:04:22 15:16:36
Title                           : NEWKM-61BAH
EXIF Metadata provided by EXIF.tools

Navigation menu