Cogent Systems SPS-TS FINGERPRINT ACCESS CONTROL READER User Manual Smart Gate Installation English
Cogent Systems Inc FINGERPRINT ACCESS CONTROL READER Smart Gate Installation English
USERS MANUAL
Smart Gate Installation Guide FCC ID : TLDSPS-TS THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS. (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED , INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 FCC Compliance and Advisory Statement This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, according to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures: 1.Reorient the receiving antenna. 2.Increase the separation between the equipment and receiver. 3.Connect the equipment into and outlet on a circuit different from that to which the receiver is connected. 4.Consult the dealer or an experienced radio/TV technician for help. Any special accessories needed for compliance must be specified in the instruction manual. Warning: A shielded-type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception. It is essential that only the supplied power cord be used. Use only shielded cables to connect I/O devices to this equipment. CAUSION: Any changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 Table of Content 1. 2. 3. 4. 5. Products Description…………………………………………………………………3 Accessories………………………………………………………………………………4 Installation……………………………………………………………………………5 User Instruction………………………………………………………………………8 Specification……………………………………………………………………14 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 1, Product Description Plastic Housing Standard Features Standard features of Smart Gate are: 500 DPI silicon fingerprint sensor Magnetic stripe card reader Standalone or networked operation Configurable security levels Remote configuration through network connection or local configuration through RS232 10/100 Base-T Ethernet connections for communication with a central database and/or administrative software 1:1 authentication or 1:N identification Wiegand output Relay drive output 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 Optional Features The following configurations and optional features are available from the Smart Gate range of terminals: Central administration and database software Contact (ISO 7816) Contact less (MiFare™ 14443A) smart card Match-On-Card Memory upgrade for storage of up to 6,000+ fingerprints Server matching using Ethernet connection 2, Accessories: 1. DB15 Cable 2. USB Cable 3. Screws, Security For Plastic Housing For Aluminum Housing 4. Screw Driver For Plastic Housing 5. Installation Guide 6. Warranty Card 209 Fair Oaks Avenue 1Ea 1Ea 4Ea FM3X12 FM4X14 1Ea T10 South Pasadena, CA 91030 1Ea 1Ea tel: (626) 799-8090 fax: (626) 799-8996 3, Installation 137.00 3.1 Follow Fig. 1 to drill mounting hole on the wall which the device will install (no need the mounting hole if mounting on the standard electrical box). Open the back panel from the device (follow instruction 3.3). Another option can be used in the plastic housing(Fig. 2). 80.00 137.00 Fig. 1 80.00 Fig. 2 3.2 Mount the back panel on the wall outlet first. 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 3.3 Plug all the necessary connectors (like DB15, Net cable) on the main device first, then mount this main device on the back panel by following the below procedures. Tips for Plastic Housing: 1. Plug the main device all the way in from above the back panel 5 cm height, then push down make sure well contact with back panel and lock. 2. Lock the Device by using the security screws provided from factory. 3. Assembly covered plate. 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 4. Smart-Gate User Manual Preparation: 1.1 Make sure the S2 switch is on “Card Management Mode”(Default setting). 1.2 Connect the Smart Gate with Category 5 network cable to network switch. Please use POE switch if try to use POE features. 1.3 Connect the Smart Gate with the COM1 of PC by using special serial cable (come with Smart Gate) 1.4 Connect the power (12V DC power supply to pin 13, 11 of DB15 socket if not using POE). 2 How to use: 2.1 Network Setting: 2.1.1 Follow the instruction of Appendix A to complete the setting of Hyper Terminal first, then open Hyper Terminal, choose function 2 ”Configure Network”, default network setting as Picture 1 (Server IP is the PC is using for communicating). Picture 1 2.2 Enroll / Matching: 2.2.1Create Admin Card: The first contactless card had been read will be the Admin card if there were no templates stored in the Smart Gate. There are three working mode 1. Enroll Mode, 2. Delete Mode, 3. Verify Mode and can be changed by presenting the Admin Card. a. The Yellow LED will start to be flashing after power on 15 seconds later, and at this moment the Smart Gate is waiting for setting Admin card. b. Choose a smart contactless card and present it to the front of the Smart Gate, then remove it away, the Smart Gate will beep and enter enroll work mode, please mark the card as Admin card. 2.2.2Enroll Fingerprint / Enroll Mode: the LED indication is Green LED on, Yellow LED flashing. a. present a smart contactless card near to the front of the Smart Gate, the Green LED will flash once then goes off and leave the yellow LED flashing if the Smart Gate read the card successfully. And please make sure the card is near the front of the Smart Gate when continue to enroll fingerprint. b, Place the finger of enroller on the sensor for at least 1 second, the Smart Gate capture the fingerprint image successfully when the Smart Gate beep once and green LED flash twice. Leave the finger on the sensor for one more second if the yellow LED keep flashing. C, Writing the fingerprint minutia into card successfully if the device beeps twice and green LED flash for three times. (the card must be within reading range). d, Writing the fingerprint minutia into card successfully again if the device beeps twice and green LED flash for three times again. (the card must be within reading range). e, the device is back to enroll work mode when remove card away from front of the device, 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 yellow LED is on and green LED flash. f, the device will be in delete work mode if present Admin card in the front of the device again, and keeping enroll the new card if present another blank card. 2.2.3 Matching fingerprint: in verify work mode match the fingerprint with minutia in the card, the yellow LED of device will flash and the device request the card. a, Present the card of user near to the front of the device, the yellow LED will flash slower than a while ago if the card had been read successfully by the device. (card can remove away from the front now) b, Place the finger on the sensor for 1 second, the device will beep when it captures the image of the fingerprint. c, Matching is completed and granted when the device beep twice and green LED flash. Matching is denied if the device beep once and red LED flash. 2.2.4 Delete fingerprint: in delete work mode to delete fingerprint only. The red LED is on and yellow LED flash. a, Present the card you wish to delete in the front of the device then the device will remove the minutia from card. b, completed after the green LED of device flash for four times. Failed when the device beep once and red LED flash for four times. P.S. The status of LED: Yellow LED is meaning for “waiting for card or finger”, green LED is meaning for successfully, red LED is meaning failed to do something. 2.2.5 Image transferring through the network while in verify work mode: a, Run Cogent-ServerBG.exe (Picture 2) Picture 2 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 b, Assign IP address for the device(Default setting: 172.60.5.103), click “Save” c, Change Gate mode to “verify”and click “Report”(Picture 3) 图3 d, Read card and matching with captured fingerprint image, Granted if the fingerprint had been enrolled into the card or denied if the fingerprint is not the one enrolled into the card. All the access log will be send to data bank through network. 2.2.6 Delete templates in the device After running Hyper Terminal, Function 5 in Admin functions is delete all template in the device flash memory. (don’ t select this function unless you want to remove everything from flash memory of the device) 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 Appendix A: Hyper Terminal (admin functions): 1, Open: \Start\AllPrograms\Accessories\Communications\HyperTerminal. (see picture 4) Picture 4 2, Typing in any “Name” in “Connection Description” windows (for example: test), then click “OK”(picture 5). Picture 5 Picture 6 3, Choosing ”COM1” in “Connect using” of “Connect To” windows (make sure the serial cable is connect to the same port) (picture 6). 4, In “Port Setting”windows, choosing “9600”for Bits per second and “Xon / Xoff” for “Flow control”. (picture 7) 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 Picture 7 Picture 8 5, Then click “OK”to complete the setting, hit the “Enter”key again and should display picture 8. 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 Appendix B: Jumper S2 setting I. Card Mode: 1. Admin mode: Default Setting (Enroll, Verify & Delete) S2 setting 2. Verify mode only: S2 setting II. Fingerprint only (No card needed) 1. Enroll Mode: 2. Verify Mode: S2 setting 209 Fair Oaks Avenue S2setting South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 5. Specification Smart-Gate Technical Specifications: Fingerprint sensor: Silicon sensor (500DPI) Enrolment method: Single finger ,multiple enrollments Extraction &Identification time: ~ 1.5 seconds FRR: FRR 0.1%-0.001% FAR: FAR 0.01%-0.0001% Allowable finger rotation: +/- 15 Template Size: 784bytes I/O interface: RS232, RS485 Baud Rate: 9600-115kbps programmable Ethernet: 10/100 w/P.O.E. Fully 802.3af compliant Mifare Card 14443 A Weigand: User programmable up to 64 bits Power: 6-12V DC Standard input (12-48V DC jumper setup) Current 210 ma @ 12v Standby: 290 ma@ 12V Operational Non 802.2af standard 12-60VDC(jumper setting) Operating Temperature: 0 to 55 C Physical Dimensions: W 3.14”x H5.42”x D2.28” Weight: 9 ounces 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 POE The Ext Board Supplies the main power to the Smart Gate device . The main power comes from POE or DB15 socket. In order to use the nonstandard and standard POE device ,Jumper J5,J6 are used. Details see below. Figure 1.1 209 Fair Oaks Avenue Standard POE Device Supply South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 Standard POE Device Power Supply If the POE device that supply power to the Smart Gate device meets the standard POE specification, that is to say, the voltage of POE device is 48V, The pin1 and pin2 of the jumper 5 (JP5) and jumper 6 (JP6) are connected together .Illustrated as Figure 1.1 . In this application, the input voltage range of the Smart Gate device that the POE device supply is 40V~60V. Figure 1.2 209 Fair Oaks Avenue Nonstandard POE Device Supply South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 NonStandard POE Device Power Supply If the POE device that supply power to the Smart Gate device does not meets the standard POE specification, that is to say, the voltage of the POE device is below 48V, The pin2 and pin3 of the jumper 5 (J5) and jumper 6 (J6) are connected together . Illustrated as Figure 1.2 . In this application, the input voltage range of the Smart Gate device that the POE device supply is 12V~40V. 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 DB15 Socket The User can use DB15 socket to get various output signals of Cogent’ s Smart Gate device . In the meantime, the user can input some signals to Cogent’ s Smart Gate device by using the DB15 socket. DB15 Definition Table 2.1 DB15 Definition 485+ WIEG0_OUT WIEG0_IN WIEG1_OUT WIEG1_IN DRVOUT WIEG0 GND 485- 10 11 12 13 14 15 232TX 232RX Power GND RELAY-2 Power input RELAY-1 Safety GND Figure 2.1 DB15 Definition 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 Signals Defination Pin1 & Pin3 (Wiegand Out Data 0, Wiegand Out Data 1) — WIEGAND output signals. Pin2 & Pin4 (Wiegand Out Data 0, Wiegand Out Data 1) — WIEGAND input signals. Pin5 ( Drvout) — Output signals, solenoid is connected to this and GND(pin11). Pin6 (Wiegand GND) — Wiegand Ground. Pin7 & Pin8(RS485-,RS485+) — RS485 connected to them. Note: About RS485 Terminal Resistor. Illustrated as figure 2.3, when pin1 & pin2 of JP4 are connected, a 120 Ω terminal resistor is connected on the RS485 BUS. Figure 2.3 RS485 Terminal Resistor Is connected Pin9 & Pin10(RS232-TX,RS232-RX) — RS232 connected to them. 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 Pin11 & Pin13 (GND, Power Input) — The user power supply. When POE is not used, Use these pins to supply power to Bigate Device. The User can use the power range is DC 6V~48V. Option 1: If using DC power supply output from 6 ~ 12 voltage, the Pin 1 & Pin 2 of JP4 are connected (on) (factory default setting); illustrated as Figure 2.4. Figure 2.4 Power Supply 12V>Vin>6V Figure 2.4 Power Supply 12V>Vin> 6V Figure 2.4 Power Supply 12V>Vin> 6V Option 2: If using DC power supply output from higher than 12 voltage to 48 voltage, the Pin 2 & Pin 3 of JP4 are connected (on); illustrated as Figure 2.5. Figure 2.5 Power Supply 48V>Vin>12V 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 Note: The POE and This Power Supply (DB15 Pin11&Pin13) can not be Used at the same time Pin12 & Pin14 (RELAY_1,RELAY_2) — Outside relay is connected to them(12V Output). Pin15 (Safety GND) — Safety Ground. 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 Ext. Board PCB Layout APPENDIX RJ45 Connection If POE is used , The connection of RJ45 is illustrated as below: 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996 209 Fair Oaks Avenue South Pasadena, CA 91030 tel: (626) 799-8090 fax: (626) 799-8996
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Create Date : 2005:08:24 11:33:41Z Modify Date : 2006:03:07 16:52:25+08:00 Page Count : 23 Creation Date : 2005:08:24 11:33:41Z Author : chenwenshi Producer : Acrobat PDFWriter 5.0 for Windows NT Mod Date : 2006:03:07 16:52:25+08:00 Metadata Date : 2006:03:07 16:52:25+08:00 Title : Smart-Gate_Installation_English.doc Creator : chenwenshi Has XFA : NoEXIF Metadata provided by EXIF.tools