Cogent Systems SPS-TS FINGERPRINT ACCESS CONTROL READER User Manual Smart Gate Installation English

Cogent Systems Inc FINGERPRINT ACCESS CONTROL READER Smart Gate Installation English

USERS MANUAL

Download: Cogent Systems SPS-TS FINGERPRINT ACCESS CONTROL READER User Manual Smart Gate Installation English
Mirror Download [FCC.gov]Cogent Systems SPS-TS FINGERPRINT ACCESS CONTROL READER User Manual Smart Gate Installation English
Document ID638954
Application IDZUM9UTqJPRWHVt4jKPJBUg==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize149.88kB (1873509 bits)
Date Submitted2006-03-21 00:00:00
Date Available2006-03-21 00:00:00
Creation Date2005-08-24 11:33:41
Producing SoftwareAcrobat PDFWriter 5.0 for Windows NT
Document Lastmod2006-03-07 16:52:25
Document TitleSmart-Gate_Installation_English.doc
Document CreatorSmart-Gate_Installation_English.doc - Microsoft Word
Document Author: chenwenshi

Smart Gate
Installation Guide
FCC ID : TLDSPS-TS
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC
RULES.
OPERATION IS SUBJECT TO THE FOLLOWING
TWO CONDITIONS. (1) THIS DEVICE MAY NOT CAUSE
HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED , INCLUDING
INTERFERENCE
THAT MAY
CAUSE
UNDESIRED
OPERATION.
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
FCC Compliance and Advisory Statement
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1)
this device may not cause harmful interference, and 2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, according to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try correct the interference by one
or more of the following measures:
1.Reorient the receiving antenna.
2.Increase the separation between the equipment and receiver.
3.Connect the equipment into and outlet on a circuit different from that to which the receiver is connected.
4.Consult the dealer or an experienced radio/TV technician for help.
Any special accessories needed for compliance must be specified in the instruction manual.
Warning: A shielded-type power cord is required in order to meet FCC emission limits and also to prevent
interference to the nearby radio and television reception. It is essential that only the supplied power cord be
used. Use only shielded cables to connect I/O devices to this equipment.
CAUSION: Any changes or modifications not expressly approved by the party responsible for compliance
could void your authority to operate the equipment.
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
Table of Content
1.
2.
3.
4.
5.
Products Description…………………………………………………………………3
Accessories………………………………………………………………………………4
Installation……………………………………………………………………………5
User Instruction………………………………………………………………………8
Specification……………………………………………………………………14
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
1, Product Description
Plastic Housing
Standard Features
Standard features of Smart Gate are:
500 DPI silicon fingerprint sensor
Magnetic stripe card reader
Standalone or networked operation
Configurable security levels
Remote configuration through network connection or local configuration
through RS232
10/100 Base-T Ethernet connections for communication with a central
database and/or administrative software
1:1 authentication or 1:N identification
Wiegand output
Relay drive output
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
Optional Features
The following configurations and optional features are available from the
Smart Gate range of terminals:
Central administration and database software
Contact (ISO 7816)
Contact less (MiFare™ 14443A) smart card
Match-On-Card
Memory upgrade for storage of up to 6,000+ fingerprints
Server matching using Ethernet connection
2, Accessories:
1. DB15 Cable
2. USB Cable
3. Screws, Security
For Plastic Housing
For Aluminum Housing
4. Screw Driver
For Plastic Housing
5. Installation Guide
6. Warranty Card
209 Fair Oaks Avenue
1Ea
1Ea
4Ea
FM3X12
FM4X14
1Ea
T10
South Pasadena, CA 91030
1Ea
1Ea
tel: (626) 799-8090
fax: (626) 799-8996
3, Installation
137.00
3.1 Follow Fig. 1 to drill mounting hole on the wall which the device will
install (no need the mounting hole if mounting on the standard electrical box).
Open the back panel from the device (follow instruction 3.3).
Another option can be used in the plastic housing(Fig. 2).
80.00
137.00
Fig. 1
80.00
Fig. 2
3.2 Mount the back panel on the wall outlet first.
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
3.3 Plug all the necessary connectors (like DB15, Net cable) on the main device
first, then mount this main device on the back panel by following the below
procedures.
Tips for Plastic Housing:
1. Plug the main device all the way in from above the back panel 5 cm height, then push
down make sure well contact with back panel and lock.
2. Lock the Device by using the security screws provided from factory.
3. Assembly covered plate.
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
4. Smart-Gate User Manual
Preparation:
1.1 Make sure the S2 switch is on “Card Management Mode”(Default setting).
1.2 Connect the Smart Gate with Category 5 network cable to network switch. Please use POE switch if try
to use POE features.
1.3 Connect the Smart Gate with the COM1 of PC by using special serial cable (come with Smart Gate)
1.4 Connect the power (12V DC power supply to pin 13, 11 of DB15 socket if not using POE).
2 How to use:
2.1 Network Setting:
2.1.1 Follow the instruction of Appendix A to complete the setting of Hyper Terminal first, then
open Hyper Terminal, choose function 2 ”Configure Network”, default network setting as Picture 1 (Server
IP is the PC is using for communicating).
Picture 1
2.2 Enroll / Matching:
2.2.1Create Admin Card: The first contactless card had been read will be the Admin card if there
were no templates stored in the Smart Gate.
There are three working mode 1. Enroll Mode, 2. Delete Mode, 3. Verify Mode and can be
changed by presenting the Admin Card.
a. The Yellow LED will start to be flashing after power on 15 seconds later, and at this moment the
Smart Gate is waiting for setting Admin card.
b. Choose a smart contactless card and present it to the front of the Smart Gate, then remove it away,
the Smart Gate will beep and enter enroll work mode, please mark the card as Admin card.
2.2.2Enroll Fingerprint / Enroll Mode: the LED indication is Green LED on, Yellow LED flashing.
a. present a smart contactless card near to the front of the Smart Gate, the Green LED will flash once
then goes off and leave the yellow LED flashing if the Smart Gate read the card successfully. And
please make sure the card is near the front of the Smart Gate when continue to enroll fingerprint.
b, Place the finger of enroller on the sensor for at least 1 second, the Smart Gate capture the
fingerprint image successfully when the Smart Gate beep once and green LED flash twice. Leave
the finger on the sensor for one more second if the yellow LED keep flashing.
C, Writing the fingerprint minutia into card successfully if the device beeps twice and green LED
flash for three times. (the card must be within reading range).
d, Writing the fingerprint minutia into card successfully again if the device beeps twice and green
LED flash for three times again. (the card must be within reading range).
e, the device is back to enroll work mode when remove card away from front of the device,
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
yellow LED is on and green LED flash.
f, the device will be in delete work mode if present Admin card in the front of the device again,
and keeping enroll the new card if present another blank card.
2.2.3 Matching fingerprint: in verify work mode match the fingerprint with minutia in the card, the
yellow LED of device will flash and the device request the card.
a, Present the card of user near to the front of the device, the yellow LED will flash slower
than a while ago if the card had been read successfully by the device. (card can remove
away from the front now)
b, Place the finger on the sensor for 1 second, the device will beep when it captures the image
of the fingerprint.
c, Matching is completed and granted when the device beep twice and green LED flash.
Matching is denied if the device beep once and red LED flash.
2.2.4 Delete fingerprint: in delete work mode to delete fingerprint only. The red LED is on and
yellow LED flash.
a, Present the card you wish to delete in the front of the device then the device will remove the
minutia from card.
b, completed after the green LED of device flash for four times. Failed when the device beep
once and red LED flash for four times.
P.S. The status of LED: Yellow LED is meaning for “waiting for card or finger”, green LED is
meaning for successfully, red LED is meaning failed to do something.
2.2.5 Image transferring through the network while in verify work mode:
a, Run Cogent-ServerBG.exe (Picture 2)
Picture 2
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
b, Assign IP address for the device(Default setting: 172.60.5.103), click “Save”
c, Change Gate mode to “verify”and click “Report”(Picture 3)
图3
d, Read card and matching with captured fingerprint image, Granted if the fingerprint had been
enrolled into the card or denied if the fingerprint is not the one enrolled into the card. All the
access log will be send to data bank through network.
2.2.6 Delete templates in the device
After running Hyper Terminal, Function 5 in Admin functions is delete all template in the device
flash memory. (don’
t select this function unless you want to remove everything from flash
memory of the device)
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
Appendix A: Hyper Terminal (admin functions):
1, Open: \Start\AllPrograms\Accessories\Communications\HyperTerminal. (see picture 4)
Picture 4
2, Typing in any “Name” in “Connection Description” windows (for example: test),
then click “OK”(picture 5).
Picture 5
Picture 6
3, Choosing ”COM1” in “Connect using” of “Connect To” windows (make sure the
serial cable is connect to the same port) (picture 6).
4, In “Port Setting”windows, choosing “9600”for Bits per second and “Xon / Xoff”
for “Flow control”. (picture 7)
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
Picture 7
Picture 8
5, Then click “OK”to complete the setting, hit the “Enter”key again and should display
picture 8.
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
Appendix B: Jumper S2 setting
I. Card Mode:
1. Admin mode: Default Setting
(Enroll, Verify & Delete)
S2 setting
2. Verify mode only:
S2 setting
II. Fingerprint only (No card needed)
1. Enroll Mode:
2. Verify Mode:
S2 setting
209 Fair Oaks Avenue
S2setting
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
5. Specification
Smart-Gate Technical Specifications:
Fingerprint sensor:
Silicon sensor (500DPI)
Enrolment method:
Single finger ,multiple enrollments
Extraction
&Identification time:
~ 1.5 seconds
FRR:
FRR 0.1%-0.001%
FAR:
FAR 0.01%-0.0001%
Allowable
finger rotation:
+/- 15
Template Size:
784bytes
I/O interface:
RS232, RS485
Baud Rate:
9600-115kbps programmable
Ethernet:
10/100 w/P.O.E. Fully 802.3af compliant
Mifare Card
14443 A
Weigand:
User programmable up to 64 bits
Power:
6-12V DC Standard input (12-48V DC jumper setup)
Current
210 ma @ 12v Standby: 290 ma@ 12V Operational
Non 802.2af standard
12-60VDC(jumper setting)
Operating Temperature: 0 to 55 C
Physical Dimensions:
W 3.14”x H5.42”x D2.28”
Weight:
9 ounces
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
POE
The Ext Board Supplies the main power to the Smart Gate device . The main power comes from POE or DB15 socket.
In order to use the nonstandard and standard POE device ,Jumper J5,J6 are used. Details see below.
Figure 1.1
209 Fair Oaks Avenue
Standard POE Device Supply
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
Standard POE Device Power Supply
If the POE device that supply power to the Smart Gate device meets the standard POE specification, that is to say, the
voltage of POE device is 48V, The pin1 and pin2 of the jumper 5 (JP5) and jumper 6 (JP6) are connected
together .Illustrated as Figure 1.1 .
In this application, the input voltage range of the Smart Gate device that the POE device supply is 40V~60V.
Figure 1.2
209 Fair Oaks Avenue
Nonstandard POE Device Supply
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
NonStandard POE Device Power Supply
If the POE device that supply power to the Smart Gate device does not meets the standard POE specification, that is
to say, the voltage of the POE device is below 48V, The pin2 and pin3 of the jumper 5 (J5) and jumper 6 (J6) are
connected together . Illustrated as Figure 1.2 .
In this application, the input voltage range of the Smart Gate device that the POE device supply is 12V~40V.
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
DB15 Socket
The User can use DB15 socket to get various output signals of Cogent’
s Smart Gate device . In the meantime, the
user can input some signals to Cogent’
s Smart Gate device by using the DB15 socket.
DB15 Definition
Table 2.1 DB15 Definition
485+
WIEG0_OUT
WIEG0_IN
WIEG1_OUT
WIEG1_IN
DRVOUT
WIEG0 GND
485-
10
11
12
13
14
15
232TX
232RX
Power GND
RELAY-2
Power input
RELAY-1
Safety GND
Figure 2.1 DB15 Definition
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
Signals Defination
Pin1 & Pin3 (Wiegand Out Data 0, Wiegand Out Data 1) — WIEGAND output signals.
Pin2 & Pin4 (Wiegand Out Data 0, Wiegand Out Data 1) — WIEGAND input signals.
Pin5 ( Drvout) — Output signals, solenoid is connected to this and GND(pin11).
Pin6 (Wiegand GND) — Wiegand Ground.
Pin7 & Pin8(RS485-,RS485+) — RS485 connected to them.
Note:
About RS485 Terminal Resistor.
Illustrated as figure 2.3, when pin1 & pin2 of JP4 are connected, a 120 Ω terminal
resistor is connected on the RS485 BUS.
Figure 2.3 RS485 Terminal Resistor Is connected
Pin9 & Pin10(RS232-TX,RS232-RX) — RS232 connected to them.
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
Pin11 & Pin13 (GND, Power Input) — The user power supply.
When POE is not used, Use these pins to supply power to Bigate Device.
The User can use the power range is DC 6V~48V.
Option 1:
If using DC power supply output from 6 ~ 12 voltage, the Pin 1 & Pin 2 of JP4 are connected (on) (factory
default setting); illustrated as Figure 2.4.
Figure 2.4 Power Supply 12V>Vin>6V
Figure 2.4 Power Supply 12V>Vin> 6V
Figure 2.4 Power Supply 12V>Vin> 6V
Option 2:
If using DC power supply output from higher than 12 voltage to 48 voltage, the Pin 2 & Pin 3 of JP4 are
connected (on); illustrated as Figure 2.5.
Figure 2.5 Power Supply 48V>Vin>12V
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
Note:
The POE and This Power Supply (DB15 Pin11&Pin13) can not be Used
at the same time
Pin12 & Pin14 (RELAY_1,RELAY_2) — Outside relay is connected to them(12V
Output).
Pin15 (Safety GND) — Safety Ground.
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
Ext. Board PCB Layout
APPENDIX
RJ45 Connection
If POE is used , The connection of RJ45 is illustrated as below:
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996
209 Fair Oaks Avenue
South Pasadena, CA 91030
tel: (626) 799-8090
fax: (626) 799-8996

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 2005:08:24 11:33:41Z
Modify Date                     : 2006:03:07 16:52:25+08:00
Page Count                      : 23
Creation Date                   : 2005:08:24 11:33:41Z
Author                          : chenwenshi
Producer                        : Acrobat PDFWriter 5.0 for Windows NT
Mod Date                        : 2006:03:07 16:52:25+08:00
Metadata Date                   : 2006:03:07 16:52:25+08:00
Title                           : Smart-Gate_Installation_English.doc
Creator                         : chenwenshi
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TLDSPS-TS

Navigation menu