Comba Telecom MRU-6100 ComFlex 600 Series DAS User Manual MRU 6100 Manual REV 1
Comba Telecom Ltd. ComFlex 600 Series DAS MRU 6100 Manual REV 1
MRU-6100 Manual REV 1
ComFlex 600 Series DISTRIBUTED ANTENNA SYSTEM USER MANUAL ComFlex-6100 QE: 1-0-0 Comba Telecom Ltd. The information contained herein is the responsibility of and is approved by the following, to whom all enquiries should be directed in the first instance: This is an unpublished work the copyright in which vests in Comba International ("Comba"). All rights reserved. The information contained herein is confidential and the property of Comba and is supplied without liability for errors or omissions. No part may be reproduced, disclosed or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied. USER MANUAL FOR COMFLEX 6100 0.1 CONTENTS Section 0.1 0.2 0.3 0.4 0.5 Page CONTENTS ....................................................................................................................................................... 3 INDEX TO FIGURES AND TABLES ...................................................................................................................... 4 HISTORY ........................................................................................................................................................... 6 GLOSSARY OF TERMS ....................................................................................................................................... 7 SAFETY NOTICES AND ADMONISHMENTS ....................................................................................................... 8 GENERAL INFORMATION .............................................................................................................................. 9 EQUIPMENT DESCRIPTION .......................................................................................................................... 11 2.1 2.2 2.3 2.4 SYSTEM DIAGRAM ......................................................................................................................................... 11 TYPICAL APPLICATION ................................................................................................................................... 11 EQUIPMENT CONSTITUTION ......................................................................................................................... 12 KIT OF PART ................................................................................................................................................... 13 INSTALLATION ............................................................................................................................................ 15 3.1 3.2 3.3 3.4 3.5 WARNINGS AND ALERTS ................................................................................................................................ 15 SITE PLANNING CONSIDERATIONS ................................................................................................................ 16 INSTALLATION PROCEDURES ......................................................................................................................... 18 EQUIPMENT CONNECTORS ........................................................................................................................... 27 EQUIPMENT CONNECTION ............................................................................................................................. 30 COMMISSIONING ....................................................................................................................................... 35 4.1 PRE-COMMISSIONING TASKS ........................................................................................................................ 35 4.2 LED INDICATORS ............................................................................................................................................ 35 4.3 DIGITAL DISPLAY INDICATORS ....................................................................................................................... 36 4.3.1 DIGITAL DISPLAY ON RFU .......................................................................................................................... 36 4.3.2 DIGITAL DISPLAY ON FOU.......................................................................................................................... 36 WEB GUI ..................................................................................................................................................... 38 5.1 WEB GUI CONNECTION ............................................................................................................................... 38 5.2 WEB GUI INTRODUCTION ........................................................................................................................... 39 5.2.1 [DEVICES] ............................................................................................................................................... 39 5.2.2 [COMMISSIONING] ................................................................................................................................ 43 5.2.3 [FIRMWARE] .......................................................................................................................................... 44 5.2.4 [MANAGEMENT] .................................................................................................................................... 46 5.3 COMMISSIONING PROCEDURE ................................................................................................................... 54 ALARMS AND TROUBLESHOOTING ............................................................................................................. 62 6.1 ALARMS ...................................................................................................................................................... 62 6.2 TROUBLESHOOTING ................................................................................................................................... 63 APPENDICES ............................................................................................................................................... 64 7.1 APPENDIX A: TOOLS FOR INSTALLATION AND MAINTENANCE .................................................................... 64 7.2 APPENDIX B: RMA (RETURN MATERIAL AUTHORIZATION) ......................................................................... 65 ENU STATUS : 1-0-0 Copyright - refer to title page Page 3 USER MANUAL FOR COMFLEX 6100 0.2 INDEX TO FIGURES AND TABLES Figure 1: Master Unit (MU) ........................................................................................................................................ 9 Figure 2: Remote Unit (RU) ..................................................................................................................................... 10 Figure 3: System Diagram ....................................................................................................................................... 11 Figure 4: Typical Application ................................................................................................................................... 11 Figure 5: ComFlex Master Unit ............................................................................................................................... 18 Figure 6: RF Unit Installation ................................................................................................................................... 19 Figure 7: FOU Installation ........................................................................................................................................ 19 Figure 8: PSU Installation ........................................................................................................................................ 20 Figure 9: Mounting Rack .......................................................................................................................................... 20 Figure 10: Angle Iron Installation ............................................................................................................................ 21 Figure 11: MU Installation ........................................................................................................................................ 21 Figure 12: Secure the Enclosure ............................................................................................................................ 21 Figure 13: Finish Installaiton ................................................................................................................................... 22 Figure 14: Wall Drilling Dimensions of LRU .......................................................................................................... 23 Figure 15: Wall Drilling Dimensions of MRU ......................................................................................................... 23 Figure 16: Install Mounting Rack on the Wall ...................................................................................................... 24 Figure 17: Hang RU onto the Mounting Rack ....................................................................................................... 24 Figure 18: Tighten the Screws at the Bottom of RU ............................................................................................ 25 Figure 19: Tighten Two Hexagon Screws ............................................................................................................. 25 Figure 20: Install PSU on RU .................................................................................................................................. 26 Figure 21: Wall Drilling Dimensions of PSU.......................................................................................................... 26 Figure 22: Install PSU on the Wall ......................................................................................................................... 27 Figure 23: MU Front Panel Connectors ................................................................................................................. 27 Figure 24: MU Rear Panel Connectors ................................................................................................................. 28 Figure 24: Mini Din Female Dimension ................................................................................................................. 28 Figure 25: RU Connectors ....................................................................................................................................... 29 Figure 26: MU Grounding (MU Rear Panel) ......................................................................................................... 30 Figure 27: RU Grounding ......................................................................................................................................... 31 Figure 28: Fiber Optical and RF Port Connection ................................................................................................ 31 Figure 29: MU Power Connection (Rear Panel) ................................................................................................... 32 Figure 30: RU Fiber Optical and RF Port Connection ........................................................................................ 33 Figure 31: PSU Power Port Connection ................................................................................................................ 33 Figure 32: Pins Allocation for “EXT_ALM” Port for RU ...................................................................................... 34 Figure 33: Pins Allocation for “BTS_ALM” Port .................................................................................................... 34 Figure 34: RFU Digital Display................................................................................................................................ 36 Figure 35: Optical Port No. and Digital Display .................................................................................................... 37 Figure 36: PC IP Address Setting........................................................................................................................... 38 Figure 37: Input IP Address ..................................................................................................................................... 38 Figure 38: Input User Name and Password .......................................................................................................... 39 Figure 39: Web GUI Main Screen .......................................................................................................................... 39 Figure 40: [Devices] Sceen ..................................................................................................................................... 40 Figure 41: MU Device - Monitoring Unit ................................................................................................................ 40 Figure 42: MU Device - Optical Unit ....................................................................................................................... 41 Figure 43: MU Device - RF Unit .............................................................................................................................. 41 Figure 44: RU Device ............................................................................................................................................... 42 Figure 45: RU Device – 700 .................................................................................................................................... 42 Figure 46: RU Device – External Alarm ................................................................................................................. 43 Figure 47: [Commissioning] Screen ....................................................................................................................... 43 Figure 48: [Firmware] Screen – Modnitoring Upgade ......................................................................................... 44 Figure 49: [Firmware] Screen – Pop-up Window 1 .............................................................................................. 44 Figure 50: [Firmware] Screen – Pop-up Window 2 .............................................................................................. 45 Figure 51: [Firmware] Screen - Swap .................................................................................................................... 45 Figure 52: [Firmware] Screen – Module Upgrade ................................................................................................ 46 Figure 53: [Management] Sceen ............................................................................................................................ 46 ENU STATUS : 1-0-0 Copyright - refer to title page Page 4 USER MANUAL FOR COMFLEX 6100 Figure 54: Management – Import&Export ............................................................................................................. 47 Figure 55: Management – IP Setting ..................................................................................................................... 48 Figure 56: Management – SNMP Setting.............................................................................................................. 48 Figure 57: Management – Security ........................................................................................................................ 49 Figure 58: Modify Password .................................................................................................................................... 49 Figure 59: Management – Device Reset ............................................................................................................... 50 Figure 60: Management – PA Reset ...................................................................................................................... 50 Figure 61: Management – Device Info................................................................................................................... 51 Figure 62: Management – Device Scanning ......................................................................................................... 51 Figure 63: Management – Device Remove .......................................................................................................... 52 Figure 64: Management – Report........................................................................................................................... 52 Figure 65: Firefox setting (1) ................................................................................................................................... 53 Figure 66: Firefox setting (2) ................................................................................................................................... 53 Figure 67: Management – Alarm Log .................................................................................................................... 54 Figure 68: Commissioning Procedure - Start........................................................................................................ 54 Figure 69: Commissioning Procedure – Device Scan ......................................................................................... 55 Figure 70: Commissioning Procedure – Params Setting .................................................................................... 55 Figure 71: Dev Info & Date/Time ............................................................................................................................ 56 Figure 72: Commissioning Procedure – MU Calibration ..................................................................................... 57 Figure 73: Commissioning Procedure – MU Calibration Finish ......................................................................... 57 Figure 74: Commissioning Procedure – RU Calibration ..................................................................................... 58 Figure 75: Commissioning Procedure – RU Calibration Finish .......................................................................... 58 Figure 76: Commissioning Procedure – MU Setup ............................................................................................. 58 Figure 77: MU Frequency Band Table ................................................................................................................... 59 Figure 78: Commissioning Procedure – RU Setup .............................................................................................. 59 Figure 79: RU Frequency Band Table ................................................................................................................... 60 Figure 80: Commissioning Procedure – Finish .................................................................................................... 60 Table 1: MU Components ........................................................................................................................................ 12 Table 2: RU Components ........................................................................................................................................ 12 Table 3: Master Unit (MU) KOP .............................................................................................................................. 13 Table 4: Remote Unit (RU) KOP ............................................................................................................................ 14 Table 5: MU Connections ........................................................................................................................................ 28 Table 6: RU Connections ......................................................................................................................................... 29 Table 7: Pin Definition of “EXT_ALM” Port for RU ............................................................................................... 34 Table 8: Pin Definition of “BTS_ALM” Port............................................................................................................ 34 Table 9: MU LED Indications .................................................................................................................................. 35 Table 10: RU LED Indications ................................................................................................................................. 35 Table 11: RFU Digital Display ................................................................................................................................. 36 Table 12: FOU Digital Display ................................................................................................................................. 37 Table 13: Import/Export Parameters ...................................................................................................................... 47 Table 14: MU Alarm List .......................................................................................................................................... 62 Table 15: RU Alarm List ........................................................................................................................................... 62 Table 16: MU Alarms Diagnosis ............................................................................................................................. 63 Table 17: RU Alarms Diagnosis .............................................................................................................................. 63 ENU STATUS : 1-0-0 Copyright - refer to title page Page 5 USER MANUAL FOR COMFLEX 6100 0.3 HISTORY Change No. ENU Details Of Change 1-0-0 This user manual first created in Sep 2014. ENU STATUS : 1-0-0 Copyright - refer to title page Page 6 USER MANUAL FOR COMFLEX 6100 0.4 GLOSSARY OF TERMS ALC Automatic Level Control ATT Attenuation BDA Bi-direction Amplifier BS Base Station BTS Base Transceiver Station DL Downlink DT Donor Terminal FOU Fiber Optical Unit GUI Graphic User Interface ID Identification LNA Low Noise Amplifier MCU Main Control Unit MT Mobile Terminal MTBF Mean Time Between Failures MU Master Unit NC Normally Closed NF Noise Figure NO Normally Open OMC Operation & Maintenance Center OMT Operation & Maintenance Terminal OP Optical Fiber OPEX OperatingExpense PA Power Amplifier PIM Passive Inter Modulation PLL Phase Locked Loop POI Point of Interconnects PSU Power Supply Unit RF Radio Frequency RFU Radio Frequency Unit RU Remote Unit SMA Sub-Miniature “A” Connector TX/RX Transmit/Receive UL Uplink VAC Volts Alternating Current VSWR Voltage Standing Wave Ratio WCDMA Wideband Code Division Multiple Access ENU STATUS : 1-0-0 Copyright - refer to title page Page 7 USER MANUAL FOR COMFLEX 6100 0.5 SAFETY NOTICES AND ADMONISHMENTS This document contains safety notices in accordance with appropriate standards. In the interests of conformity with the territory standards for the country concerned, the equivalent territorial admonishments are also shown. Any installation, adjustment, maintenance and repair of the equipment must only be carried out by trained, authorized personnel. At all times, personnel must comply with any safety notices and instructions. Specific hazards are indicated by symbol labels on or near the affected parts of the equipment. The labels conform to international standards, are triangular in shape, and are coloured black on a yellow background. An informative text label may accompany the symbol label. Hazard labeling is supplemented by safety notices in the appropriate equipment manual. These notices contain additional information on the nature of the hazard and may also specify precautions. Warning: These draw the attention of personnel to hazards that may cause death or injury to the operator or others. Examples of use are cases of high voltage, laser emission, toxic substances, point of high temperature, etc. WARNING! To comply with FCC RF exposure compliance requirements, each individual antenna used for this transmitter must be installed to provide a separation distance greater than 122cm or more from all persons during normal operation and must not be co-located with any other antenna for meeting RF exposure requirements. The design of the antenna installation needs to be implemented in such a way so as to ensure RF radiation safety levels and non-environmental pollution during operation. Note: Antennas, feeders and couplers are not included in the packing list; solution provider should consider these accessories according to site conditions. WARNING! Antenna gain should not exceed 12.5 dBi. WARNING! The design of the antenna installation needs to be implemented in such a way so as to ensure RF radiation safety levels and non-environmental pollution during operation. WARNING! For 1710-1755 MHz, installation must comply with 27.50(d)(4) max 1 W EIRP and fixed station ABSOLUTE max 10 m antenna height above earth. WARNING! This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. Alert: These draw the attention of personnel to hazards that may cause damage to the equipment. An example of use is the case of static electricity hazard. Caution notices may also be used in the handbook to draw attention to matters that do not constitute a risk of causing damage to the equipment but where there is a possibility of seriously impairing its performance, e.g. by mishandling or gross maladjustment. Warnings and Cautions within the main text do not incorporate labels and may be in shortened form. End of Section ENU STATUS : 1-0-0 Copyright - refer to title page Page 8 USER MANUAL FOR COMFLEX 6100 1 GENERAL INFORMATION The ComFlex 600 Series Distributed Antenna System (hereinafter called “ComFlex”) consists of Master Unit (MU) and Remote Unit (RU). The MU includes the MU Chassis, Power Supply Unit (PSU), Fiber Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an integrated design which supports 6 independent bands, 700MHz (lower ABC)/700MHz (upper C), 800MHz/850MHz, 1900MHz and AWS band. The low signal transmission loss of optical fiber is applicable for long distance transmission. ComFlex can support the optical transmission of up to 6.5dBo optical loss, equivalent to 8 miles fiber length. Main feature: Industry’s first DAS system with superior PIM performance MINI-DIN RF connectors. Independent coupling port for uninterrupted network testing. Modularized Master Unit supports flexible field upgrade and maintenance. Independent gain control for each RF source. High MTBF and low noise design with modular PSU and convection cooling. RF module supports both simplex and duplex. Compact slim Remote Unit for OPEX saving. Supports multi-operator and mix mode application. Optical link auto gain control. Web based GUI for intelligent commissioning and configuration. The figures below show the ComFlex Master and Remote unit enclosure. Figure 1: Master Unit (MU) ENU STATUS : 1-0-0 Copyright - refer to title page Page 9 USER MANUAL FOR COMFLEX 6100 Figure 2: Remote Unit (RU) End of Section ENU STATUS : 1-0-0 Copyright - refer to title page Page 10 USER MANUAL FOR COMFLEX 6100 2 EQUIPMENT DESCRIPTION 2.1 SYSTEM DIAGRAM Optical Fiber MU RU Antenna Figure 3: System Diagram On the DL, signals from the BTSs or BDA are converted into optical signals after amplification in the MU.Then the optical signals are transmitted to the RU via optical fiber. The Optical TX/RX Module of RU converts the DL optical signals into RF signals. After amplification, the signals are transmitted at the MT port to the service antenna. On the UL, the signals transmitted by the mobile are converted into optical signals, and then via the UL optical fiber, the signals are transmitted to MU, which then converts the optical signals back to RF signals. 2.2 TYPICAL APPLICATION Shown below are the typical SISO and MIMO applications of MU and RUs. Figure 4: Typical Application ENU STATUS : 1-0-0 Copyright - refer to title page Page 11 USER MANUAL FOR COMFLEX 6100 2.3 EQUIPMENT CONSTITUTION MU consists of the following parts: Table 1: MU Components Module MU01-RACK MU01-PSU Description Master Unit Chassis includes eight slots for RF Unit, two slots for Fiber Optical Unit, and one slot for Power Supply Unit. iDAS Master Unit Power Supply Unit (PSU) converts the input voltage into stable DC to supply power for other modules of Master Unit. MU01-FOU Master Unit Fiber Optical Unit (FOU) completes optical signal and RF signal conversion. One FOU has four optical ports, which means each FOU can support up to four RUs. MU01-RFU Master Unit RF Unit completes separation and combination of uplink and downlink signal with independent gain control, supports either simplex or duplex. RU consists of the following parts: Table 2: RU Components Module LRU01-6100 MRU01-6100 LRU01-PSU ENU STATUS : 1-0-0 Description Low Power Remote Unit (1W); A compact and slim design which supports 6 bands, including 700MHz (lower ABC, upper C), 800MHz/850MHz, 1900MHz and AWS band. Medium Power Remote Unit (5W); A compact and slim design which supports 6 bands, including 700MHz (lower ABC, upper C), 800MHz/850MHz, 1900MHz and AWS band. Remote Unit Power Supply Unit (PSU) converts the input AC voltage into stable DC, to supply power for Remote Unit. It can be installed on RU or on wall beside RU. Copyright - refer to title page Page 12 USER MANUAL FOR COMFLEX 6100 2.4 KIT OF PART Table 3: Master Unit (MU) KOP Item Qty MU Chassis RF Unit (RFU) 1~8 Fiber Optical Unit (FOU) 1~2 Power Supply Unit (PSU) Power Supply Cable (13 Feet 1 inch) Communication Cable Right Angle Bracket (for MU 19“rack mounting) Left Angle Bracket (for MU 19“ rack mounting) ENU STATUS : 1-0-0 Copyright - refer to title page Image Page 13 USER MANUAL FOR COMFLEX 6100 Table 4: Remote Unit (RU) KOP Item Qty Remote Unit RU Power Supply Unit (with1 foot 9 inches. DC cable and 13 feet 1 inch AC cable ) Mounting Rack (for RU wall mounting) Masonry Bolt (set) M8x80 ( for RU concrete wall mounting) Masonry Bolt (set) M8x80 (for PSU concrete wall mounting) Nuts M6x10, Spring Washers Φ6, Plain Washers Φ6 (for PSU mounting on RU) 2 pieces each Nuts M6x10, Spring Washers Φ6, Plain Washers Φ6 (for RU grounding) 2 pieces each GND Cable (for RU grounding) Nuts M6x10, Spring Washers Φ6, Plain Washers Φ6 (for PSU grounding) 2 pieces each GND Cable (for PSU grounding) Image End of Section ENU STATUS : 1-0-0 Copyright - refer to title page Page 14 USER MANUAL FOR COMFLEX 6100 3 INSTALLATION 3.1 WARNINGS AND ALERTS Laser Laser light can cause damage to eyes. Laser light is not visible. Viewing it directly does not cause pain. The iris of the eye will not close when viewing a bright light. Consequently, serious damage to the retina of the eye is possible. NEVER LOOK INTO THE END OF A FIBER WHICH MAY HAVE A LASER COUPLED TO IT. Radio Frequency Energies There may be situations, particularly for workplace environments near high-powered RF sources, where recommended limits for safe exposure of human beings to RF energy could be exceeded. In such cases, restrictive measures or actions may be necessary to ensure the safe use of RF energy. High Voltage The equipment has been designed and constructed to prevent practicable danger, as far as reasonably possible. Any work activity on or near equipment involving installation, operation or maintenance must be free from danger, as far as reasonably possible. Where there is a risk of damage to electrical systems involving adverse weather, extreme temperatures, wet, corrosive or dirty conditions, flammable or explosive atmospheres, the system must be suitably installed to prevent danger. Protective Earthing Equipment provided for the purpose of protecting individuals from electrical risk must be suitable for the purpose and properly maintained and used. Handling Precautions This covers a range of activities including lifting, lowering, pushing, pulling, carrying, moving, holding or restraining an object or person. It also covers activities that require the use of force or effort, such as pulling a lever, or operating power tools. Electrostatic Discharge (ESD) Observe standard precautions for handling ESD-sensitive devices. Assume that all solid-state electronic devices are ESD-sensitive. Ensure the use of a grounded wrist strap or equivalent while working with ESD-sensitive devices. Transport, store, and handle ESD-sensitive devices in static-safe environments. ENU STATUS : 1-0-0 Copyright - refer to title page Page 15 USER MANUAL FOR COMFLEX 6100 3.2 SITE PLANNING CONSIDERATIONS 3.2.1 SITE PLANNING Site Considerations The MU is designed to be located indoors to facilitate coupling of BTS signals and power supply connections. The input range of MU RF unit is 10~30 dBm. The site consideration for RU is listed below: The distance between the service antenna of RU and coverage area should satisfy line of sight requirements for maximum coverage area. The maximum fiber length is 8 miles, with a maximum path loss of 6.5dBo. The system delay of the optical system must be taken into consideration when there are neighboring BTS sites overlapping in coverage. Installation Location Mounting surface shall be capable of supporting the weight of the equipment. In order to avoid electromagnetic interference, a proper mounting location must be selected to minimize interference from electromagnetic sources such as large electrical equipment. Environmental Humidity has an adverse effect on the reliability of the equipment. It is recommended to install the equipment in locations having stable temperature and unrestricted air-flow. The installation location for the system should be well ventilated. The equipment has been designed to operate at the temperature range and humidity level as stated in the product specifications. Powering The power supply unit (PSU) provides power to all modules within the equipment. Depending on the product variant, it is recommended that the PSU operates on a dedicated AC circuit breaker or fused circuit. Grounding Requirement Verify that the equipment has been well grounded. This includes antennas and all cables connected to the system. Ensure lightning protection for the antennas is properly grounded. Cable Routing Depending on equipment configuration, a variety of types of cables are connected to the MU and RU: coaxial cables, optical fibers, power cable, communication cable, and commissioning cable. Where applicable, ensure cables are properly routed and secured so that they are not damaged. Manual Handling ENU STATUS : 1-0-0 Copyright - refer to title page Page 16 USER MANUAL FOR COMFLEX 6100 During transportation and installation, take necessary handling precautions to avoid potential physical injury to the installation personnel and the equipment. 3.2.2 SYSTEM INSTALLATION CHECKLIST Working space available for installation and maintenance for each mounting arrangement. Ensure unrestricted airflow. Ensure earthing point is within reach of the ground wire. (2m; 6 ft. 10 in.). Ensure a power source is within reach of the power cord and the power source has sufficient capacity. Where appropriate, ensure unused RF connectors are terminated. Where appropriate, ensure unused optical fiber connectors are protected. Do not locate the equipment near large transformers or motors that may cause electromagnetic interference. Reduce signal loss in feeder cable by minimizing the length and number of RF connections. Ensure the equipment will be operated within the stated environment (refer to datasheet). Where needed, couple BTS RF signal with a coupler to prevent damaging the equipment. Where appropriate, confirm available of suitably terminated grade of RF and optical fiber. Observe handling of all cables to prevent damage. ENU STATUS : 1-0-0 Copyright - refer to title page Page 17 USER MANUAL FOR COMFLEX 6100 3.3 INSTALLATION PROCEDURES 3.3.1 GOODS INWARDS INSPECTION ComFlex was factory tested, inspected, packed, and delivered to the carrier with utmost care. Do not accept shipment from carrier which shows damage or shortage until the carrier’s agent endorses a statement of the irregularity on the face of the carrier’s receipt. Without documentary evidence, a claim cannot be processed. Open and check each package against the packing list. For any shortage, contact Comba Telecom Systems. Do not remove items from packing materials until installation. 3.3.2 TOOLS See Appendix A for a full list of tools required for installation and maintenance. 3.3.3 PREPARATION Optical Fiber: Fiber optic cables require proper handling. Do not stretch, puncture, or crush the fiber cable(s) with staples, heavy equipment, doors, etc. Always maintain the minimum bending radius specified by the cable manufacturer. The minimum bend radius is usually 10 times the cable’s outer diameter. In the case of single optical fiber that is not in a cable, the minimum bending radius to be observed is 3cm. (1.2”) 3.3.4 MU ASSEMBLING ComFlex Master Unit consists of 4 parts: Chassis, RFU, FOU and PSU. All the units are packed separately. Follow the steps below to assemble. Figure 5: ComFlex Master Unit ENU STATUS : 1-0-0 Copyright - refer to title page Page 18 USER MANUAL FOR COMFLEX 6100 Step1: RF Unit installation: Remove RFU slot cover plate on Chassis, insert RFU and fasten the screws. (Each Unit can be installed in any one of eight RFU slots) Figure 6: RF Unit Installation Step2: FOU installation: Remove FOU slot cover plate on Chassis, insert FOU and fasten the screws. (Each Unit can be installed in either one of two FOU slots) Figure 7: FOU Installation Step3: PSU installation: Remove PSU slot cover plate on the right side of Chassis, insert PSU and fasten the screws. ENU STATUS : 1-0-0 Copyright - refer to title page Page 19 USER MANUAL FOR COMFLEX 6100 Figure 8: PSU Installation 3.3.5 MU IN 19” RACK MOUNTING MU is an indoor type device; the installation procedures are shown as below: Step 1: Install right angle bracket and left angle bracket on back of the mounting rack. (Rack nuts and screws are not provided.) Use rack nuts and screws as recommended by rack manufacturer. Figure 9: Mounting Rack ENU STATUS : 1-0-0 Copyright - refer to title page Page 20 USER MANUAL FOR COMFLEX 6100 Figure 10: Angle Iron Installation Step2: Slide the MU on to the angle brackets and confirm it is level. Figure 11: MU Installation Step 3: Attach the MU onto the rack with the recommended rack screws. Figure 12: Secure the Enclosure ENU STATUS : 1-0-0 Copyright - refer to title page Page 21 USER MANUAL FOR COMFLEX 6100 Step 4: Finish installation. Figure 13: Finish Installaiton 3.3.6 RU WALL MOUNTING RU wall mounting steps are shown below. Step 1: Select the wall mount location according to the following criteria: General surroundings If mounting on dry wall, 0.75 In (min) plywood backboard is required to support the weight of the equipment. Ventilated and easy-to-reach area (for maintenance and on-site inspection) Proximity to DAS antenna in order to minimize cable loss Step 2: Measure and mark the locations of 4 holes on the wall. Refer to Fig 14 for the wall drilling dimensions of LRU and Fig 15 for the wall drilling dimensions of MRU. Use a Φ10 drill bit for masonry bolts. ENU STATUS : 1-0-0 Copyright - refer to title page Page 22 USER MANUAL FOR COMFLEX 6100 21.26 in. (540mm) 6.65 in. (169mm) Figure 14: Wall Drilling Dimensions of LRU 23.62 in. (600mm) 6.65 in. (169mm) Figure 15: Wall Drilling Dimensions of MRU Step 3: Attach the mounting rack on a wall. If a concrete wal, use the 2 M8×80 masonry bolts. (Bolts are provided; lag bolts or screws are not provided for plywood mounting) ENU STATUS : 1-0-0 Copyright - refer to title page Page 23 USER MANUAL FOR COMFLEX 6100 Two M8×80 masonry bolt Figure 16: Install Mounting Rack on the Wall Step 4: Ensure the antenna and other connectors are facing down, hang RU onto semicircle slot of mounting rack. Figure 17: Hang RU onto the Mounting Rack Step 5: Tighten the bottom two M8×80 masonry bolts on RU. ENU STATUS : 1-0-0 Copyright - refer to title page Page 24 USER MANUAL FOR COMFLEX 6100 Two M8×80 masonry bolt Figure 18: Tighten the Screws at the Bottom of RU Step 6: Tighten M6×20 hexagon screws on the left and right sides of RU to fasten it with mounting rack. M6×20 hexagon screws Figure 19: Tighten Two Hexagon Screws 3.3.7 PSU INSTALLATION RU Power Supply Unit should be installed after the RU is mounted. RU Power Supply Unit can be installed in two ways – attached to RU or mounted on wall. PSU attached to RU Attach the PSU on the right of the RU with two M6×10 hexagon screws (screws are provided). ENU STATUS : 1-0-0 Copyright - refer to title page Page 25 USER MANUAL FOR COMFLEX 6100 Figure 20: Install PSU on RU PSU mounted on wall Step 1: Measure and mark the locations of 2 holes on the wall close to RU. Use Φ10 drill head. (NOTE: DC cable is 1 foot 9 inches; AC cable is 13 feet 1 inch) 4.37 in. (380mm) Distance between RU and PSU should be no more than 20 inches (0.5m) 14.96 in. (111mm) Figure 21: Wall Drilling Dimensions of PSU Step 2: Attach the PSU on the wall with two M8×80 hexagon screws (Screws are provided) ENU STATUS : 1-0-0 Copyright - refer to title page Page 26 USER MANUAL FOR COMFLEX 6100 Figure 22: Install PSU on the Wall 3.3.8 DRIP-LOOP Comba recommends that every horizontal cable entry to the equipment forms a 'U' before it’s entry to the equipment. Any accumulated water on the cable will drip down at the bottom of the loop and will not climb up to the equipment. 3.4 EQUIPMENT CONNECTORS The figures below present the connectors of ComFlex MU. Figure 23: MU Front Panel Connectors ENU STATUS : 1-0-0 Copyright - refer to title page Page 27 USER MANUAL FOR COMFLEX 6100 10 11 12 13 14 Figure 24: MU Rear Panel Connectors Identifier 1. OP1~OP4 2. LED indicator 3. BTS_ALM 4. OMT 5. LAN 6. TX/RX 7. RX 8. 9. 10. FOU 11. AUX 12. 28 GND 13. UL1,DL1; UL2,DL2; UL3,DL3 14. AC100~240V Table 5: MU Connections Functional Description SC/APC optical fiber access port LED indicator. See Chapter 4 for the description of each indicator. DB9-F connector for BTS alarm. RJ45 connector connects PC with equipment for local and remote monitoring. Reserved RJ45 port for remote monitoring. RF access port, Mini Din* female connector. RF access port, Mini Din* female connector. Digital display tube. See chapter 4 for the detailed description. Grounding connector. Communication port with extension optical unit. Reserved interface for source calibration unit. Provide 28V power supply for extension units (FOU and source calibration unit). QMA female connector, reserved for RF interface of extended FOU and single soure calibration unit. AC power supply connector. M20X1 *Mini Din Female Dimension is shown in figure below. Figure 25: Mini Din Female Dimension ENU STATUS : 1-0-0 Copyright - refer to title page Page 28 USER MANUAL FOR COMFLEX 6100 OP EXT_ALM RS-485 LAN DC 28V OP ALM PWR RUN TX_EXT RX_EXT TEST ANT Figure 26: RU Connectors Identifier ANT OP EXT_ALM RS-485 LAN DC28V TX_EXT RX_EXT TEST ENU STATUS : 1-0-0 Table 6: RU Connections Functional Description MINI Din female cable connector, antenna system connection port SC/APC optical fiber access port External alarm port. It provides an alarm report interface for other devices to report their alarms to CMS. Reserved. Reserved. Power supply interface, conntects with Power Supply Unit. QMA female connector, downlink RF coupling port. QMA female connector, uplink RF coupling port. QMA female connector, downlink output power test port. Copyright - refer to title page Page 29 USER MANUAL FOR COMFLEX 6100 3.5 EQUIPMENT CONNECTION 3.5.1 GROUNDING CONNECTION WARNING! This unit must always be grounded. Consult an appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Do not connect power before grounding. 3.5.2 MU GROUNDING CONNECTION Step 1: Connect the GND cable to the GND connector and the building EARTH. Recommended GND cable size is # 12 AWG. Step 2: Ensure the GND cable is connected to building GND. Grounding Connector Figure 27: MU Grounding (MU Rear Panel) 3.5.3 RU GROUNDING CONNECTION Step 1: Connect one side of the supplied copper wire GND cable to right side of RU with two M6×10 hexagon Screws (screws are provided). Connect the other side of the supplied copper wire GND cable to the building EARTH with two M6 screws (screws are not provided). Step 2: Connect one side of the supplied copper wire GND cable to RU with two M6×10 hexagon Screws (screws are provided). Connect the other side of the supplied copper wire GND cable to the building EARTH with two M6 screws (screws are not provided). Note: There are two GND ports on both sides of PSU, users can use one of them according to real situation. Step 3: Ensure all GND cables are well grounded to building GND. ENU STATUS : 1-0-0 Copyright - refer to title page Page 30 USER MANUAL FOR COMFLEX 6100 Figure 28: RU Grounding 3.5.4 MU CONNECTIONS Step1: Connect the MU OP (optical) port to one of the RU OP port. (NOTE: requires Single Mode fiber with SC/APC connectors; MAXIMUM OPTICAL LOSS = 6.5dBo) Step 2: For duplex application, connect the MU RFU TX/RX port to the RF Source (BTS or BDA) using 50Ohm coaxial cable. For simplex application, connect the MU RFU TX/RX port to the RF Source downlink, and then connect MU RFU RX port with RF Source uplink. (NOTE: Coaxial cable must be miniDIN Male on the MU side) Local commissioning & Remote monitoring port Fiber optic port LED indicator BTS Alarm Reserved RF port, to BTS Figure 29: Fiber Optical and RF Port Connection ENU STATUS : 1-0-0 Copyright - refer to title page Page 31 USER MANUAL FOR COMFLEX 6100 Step 3: Connect the power cable to the power supply port (100-240VAC, 1Amp maximum). Power Connection Figure 30: MU Power Connection (Rear Panel) 3.5.5 RU CONNECTION Step 1: Connect the RU OP (optic) port to one of the OP port located on MU FOU front panel. Step 2: Connect ANT port to a broadband antenna using 50Ohm coaxial cabel. Note: coaxial cable must be mini-D male on the RU side, antenna shoule be 50Ohm. Step 3: Connect DC 28V port to RU Power Supply Unit DC 28V port. Step 4: Connect power cable on PSU with the public power grid (110~220VAC, 3Amp maximum). ENU STATUS : 1-0-0 Copyright - refer to title page Page 32 USER MANUAL FOR COMFLEX 6100 Local commissioning port External alarm port Optical fiber port OP EXT_ALM DC power port LAN RS-485 DC 28V OP ALM PWR RUN TX_EXT RX_EXT TEST ANT RF port, to antenna Downlink RF coupling port Uplink RF coupling port Downlink output power test port LED Indicators Figure 31: RU Fiber Optical and RF Port Connection AC Power connection DC 28V AC 100V-240V 50Hz/60Hz DC power connection – to RU Figure 32: PSU Power Port Connection 3.5.6 RU EXTERNAL ALARM CONNECTION For RU, this is a 4-pin connector. The following figure and table show the pin allocation and definition. Pin numbering are shown looking-into the connector on the enclosure. ENU STATUS : 1-0-0 Copyright - refer to title page Page 33 USER MANUAL FOR COMFLEX 6100 Figure 33: Pins Allocation for “EXT_ALM” Port for RU Table 7: Pin Definition of “EXT_ALM” Port for RU Pin number Alarm definition EXT. Alarm 1 GND EXT. Alarm 2 GND Note: Users need to configure Ext Alm 1~2 on WEB GUI to realize External Alarm (Refer to Chapter 5). 3.5.7 MU BTS ALARM CONNECTION The equipment alarms can be signaled to the BTS via voltage-free relay contacts. The voltage-free relay connections are connected to the DB-9 port “BTS_ALAM” located on the MU. The following figure and table show the pin allocation and definition. BTS_OPEN BTS_ COM BTS_CLOSE Figure 34: Pins Allocation for “BTS_ALM” Port Pin Number 4~9 Table 8: Pin Definition of “BTS_ALM” Port Definition Description BTS_OPEN Connects to the open terminal of the voltage free relay. BTS_COM Connects to the common terminal of the voltage free relay. BTS_CLOSE Connects to the close terminal of the voltage free relay. NC Reserved. 3.5.8 CONNECT TO PC The local commissioning and management for MU and RU is achieved through connecting to the WEB base GUI. Connect MU to PC Connect MU “OMT” port (RJ45) to the RJ45 port of PC with supplied Ethernet cable to achieve local monitoring and management. End of Section ENU STATUS : 1-0-0 Copyright - refer to title page Page 34 USER MANUAL FOR COMFLEX 6100 4 COMMISSIONING 4.1 PRE-COMMISSIONING TASKS After equipment installation, perform the following steps before equipment powering and commissioning, check that the expected voltage, current, and power levels do not violate any ratings. Double check all connections including ground before applying power. Do not manipulate circuits or make changes when power is applied: Visually inspect the power connection within the equipment. Ensure that all cables are correctly and securely connected, including power cables, grounding wires, RF cables and optical cables. Check grounding connection and verify that the ground resistance is less than 5Ω. Connect the equipment to the PC. Power on MU and RU. Monitor the initialization of the MU and RU though the LEDs on the panel. Refer to detailed LEDs information in the next section. 4.2 LED INDICATORS Diagnostic LEDs are located on the MU front panel and RU bottorm panel; each indicates the status of a particular function: LED Indicator PWR RUN ALM OP LED Indicator PWR RUN ALM OP ENU STATUS : 1-0-0 Table 9: MU LED Indications Normal Status Indication Power indicator. If LED is off, it indicates the Steady green system has no power. MU operation indicator. After initialization (1~2 Flashing green minutes), the LED should flash at once per sec. (1 time/sec) (When upgrade firmware, LED will flash rapidly) Alarm indicator. If LED is RED, there is an OFF alarm. Located on Fiber Optical Unit (FOU), it is an indicator for receive optical power. If LED is off, Steady green it indicates the receiving optical power is less than -10dBm. Table 10: RU LED Indications Normal Status Indication Power indicator. If LED is off, it indicates the Steady green system has no power. RU operation indicator. After initialization (1~2 Flashing green minutes), the LED will flash once per sec. (When (1 time/sec) upgrade firmware, LED will flash rapidly) off Alarm indicator. If LED is RED, there is an alarm. Steady green Located on Fiber Optical Unit (FOU), it is an indicator of Receiving optical power. If LED is off, it indicates the receiving optical power is less than -10dBm. Copyright - refer to title page Page 35 USER MANUAL FOR COMFLEX 6100 4.3 4.3.1 DIGITAL DISPLAY INDICATORS DIGITAL DISPLAY ON RFU The digital display tube on RFU shows the DL input power. The range of DL input power shown on the display tube is from -19 to 33 (dBm), when DL input power is lower than -19dBm, it will show L, when DL input power is higher than 33, it will display H. Figure 35: RFU Digital Display Figure Table 11: RFU Digital Display DL Input Power Level < -19dBm -19~33 -19~33dBm 4.3.2 33dBm DIGITAL DISPLAY ON FOU The digital display tube on optical module has two digits. The first digit will display A, b, C and d which presents the No. of optical port. Refer to below figure for the relationship. The second digit will display the optical loss of each port. See the following table for the relationship of figure and optical loss. ENU STATUS : 1-0-0 Copyright - refer to title page Page 36 USER MANUAL FOR COMFLEX 6100 Figure 36: Optical Port No. and Digital Display Figure Table 12: FOU Digital Display Optical Loss 0~9 0~9dBo 9dBo End of Section ENU STATUS : 1-0-0 Copyright - refer to title page Page 37 5 WEB GUI ComFlex can be monitored and controlled by WEB GUI, follow below contents to achive system parameter setting and commissioning. 5.1 WEB GUI CONNECTION Step 1: Connect MU OMT port to PC RJ45 port with the supplied Ethernet cable to set up a physical connection. Step 2: Go to laptop Control Panel\Network and Internet\Local Area Connection. Right click it and click Properties. Then follow the steps shown in figure below. Figure 37: PC IP Address Setting Step 3: Open browser (browser IE7.0, IE8.0, Chrome or Firefox, suggest disply resolution is 1024×768), input Web GUI IP address: 192.168.8.101, click [Enter]. Figure 38: Input IP Address Step 2: Input User Name: admin; Password (default password: admin). Click [Log in]. ENU STATUS : 1-0-0 Copyright - refer to title page Page 38 USER MANUAL FOR COMFLEX 6100 Figure 39: Input User Name and Password 5.2 WEB GUI INTRODUCTION After login, the Web GUI main screen will appear. Figure 40: Web GUI Main Screen On Comba Web GUI Home page, there are four Menu bars: [Devices], Commissioning], [Firmware] and [Management]. 5.2.1 [DEVICES] The [Devices] page shows the actual connection diagram of MU and RU. ENU STATUS : 1-0-0 Copyright - refer to title page Page 39 USER MANUAL FOR COMFLEX 6100 Click here for main unit management page Click here for FOU management page Click here for RFU management page Click here for RU management page Figure 41: [Devices] Sceen MU Main Management Screen This part shows MU basic information This part shows MU alarm status Click here to enable/disable alarm Figure 42: MU Device - Monitoring Unit Optical Unit Management Screen ENU STATUS : 1-0-0 Copyright - refer to title page Page 40 USER MANUAL FOR COMFLEX 6100 Click here to enable/disable optical RX/TX alarm FOU port number Optical loss between MU and RU, the value is over 15dB when MU and RU are not connected well Optical power alarm. Alarm is triggered when optical power is less than -10dBm. Indicator will turn from green to red Figure 43: MU Device - Optical Unit Note: MU transmit optical power is -4~-2dBm. RF Unit Management Screen Click here to on/off RF switch and modify attenuator Slot number Band and operator information of RFU RF parameter Commissioning and calibration status Downlink input power overdrive alarm Figure 44: MU Device - RF Unit Remote Unit Management Screen Click RU photo, users can visit RU directly. Make sure two steps are done before visit RU: RU and MU are connected by optical fiber. RU device scanning is done. Note: Go to [Commissioning] page or [Management] page for device scanning. ENU STATUS : 1-0-0 Copyright - refer to title page Page 41 USER MANUAL FOR COMFLEX 6100 This part shows RU basic information RU common information table Select band to check relative band information Band information table Figure 45: RU Device NOTE: There are three statuses for PA Service: Normal, Recovery and Shutdown. If PA output power or reflected power exceeds the threshold (32dBm for LRU, 39dBm for MRU), software will trigger Recovery: It will reset PA and then re-detect the PA output power and reflected power, if they are normal, the PA Service Status will turn to Normal, if PA output power or reflected power is still over the threshold, PA Service Status will turn to Recovery again. If PA output power or reflected power is still over the threshold after six times of PA Recovery, PA Service status will be Shutdown which will need to be reset manually. Reset at Management > PA Reset. Click on a specific band on the left side of RU Device page, the corresponding band information will show. Select 700MHz band 700MHz RF parameter setting table 700MHz alarm information and configuration table Figure 46: RU Device – 700 ENU STATUS : 1-0-0 Copyright - refer to title page Page 42 USER MANUAL FOR COMFLEX 6100 Figure 47: RU Device – External Alarm 5.2.2 [COMMISSIONING] A work flow of the commissioning process is shown on [Commissioning] page. Click the [Start] button, the software will guide you through the commissioning step by step. For details, please refer to chapter 5.3. Figure 48: [Commissioning] Screen ENU STATUS : 1-0-0 Copyright - refer to title page Page 43 USER MANUAL FOR COMFLEX 6100 5.2.3 [FIRMWARE] There are three functions on the [Firmware] bar: [Monitoring Upgrade], [Swap] and [Module Upgrade]. [Monitoring Upgrade] is used to upgrade MCU software, [Swap] is to replace current MCU firmware version to the previous one, [Module Upgrade] is to upgrade software of each module. Follow steps shown in below figure to upgrade MCU firmware. Step3:Click to upgrade software Step1:select device Step2:Click to select software that to be updated Figure 49: [Firmware] Screen – Modnitoring Upgade Step 4: After clicking , a window will pop up and click Figure 50: [Firmware] Screen – Pop-up Window 1 Step 5: Wait for 2~4 minutes while MU/RU is being reset. ENU STATUS : 1-0-0 Copyright - refer to title page Page 44 USER MANUAL FOR COMFLEX 6100 Figure 51: [Firmware] Screen – Pop-up Window 2 Step 6: Clear browsing history and cookies from browser. NOTE: For MU software upgrade, users need to re-login Web GUI after reset is done. Follow steps shown in below figure to Swap MCU firmware. Step1:select device Step2:Click to swap firmware to previous version Figure 52: [Firmware] Screen - Swap Follow steps shown in below figure to upgrade module firmware. ENU STATUS : 1-0-0 Copyright - refer to title page Page 45 USER MANUAL FOR COMFLEX 6100 Step1:select device Step2:Click to select software that to be updated Step3:Click to upgrade software Figure 53: [Firmware] Screen – Module Upgrade Note 1: There are two loctiaons for Optical module – Module-L which is on the left and Module-R which is on the right side of MU. Note 2: FSK module is in side Optical modul. Noet 3: Adapter Module means RF module, [Slot] in the Adapter Module software upgrade table refers to the 8 slost on the MU Rack and the series number is from left to right. 5.2.4 [MANAGEMENT] Other parameters can be configured on [Management] page. Clink here to enter the corresponding page Figure 54: [Management] Sceen ENU STATUS : 1-0-0 Copyright - refer to title page Page 46 USER MANUAL FOR COMFLEX 6100 There are nine function bar lised in the left side of the [Mangement] page. Below figures are the introduction of each function bar. Inport&Export Select a device, the device information will show. Parameter configurations can be input and output in this page Figure 55: Management – Import&Export Blow table list the parameters that can be import/export: Device MU Table 13: Import/Export Parameters Paremeter Device Parameter Alarm Enable Alarm Enable ATT value ATT value RF Switch RF Switch RU SNMP parameter Over temperature alarm threshold DL over output power threshold External Alarm level Import and Export can help users quickly configure MU and RU parameters. For example, if one MU/RU finished configuration, users can export its parameters and save as a file in PC, and then import this file to other MU/RU to fast finish the MU/RU parameter setting. IP Setting ENU STATUS : 1-0-0 Copyright - refer to title page Page 47 USER MANUAL FOR COMFLEX 6100 Configure MU IP address for remote monitoring of MU Figure 56: Management – IP Setting Note: For remote monitoring, the IP Address must be set correctly according to the location IP of remote connection. If more than one equipment is connected to the public network through the same router, the router’s local IP CANNOT be set as 192.168.8.*. SNMP Setting Figure 57: Management – SNMP Setting Security ENU STATUS : 1-0-0 Copyright - refer to title page Page 48 USER MANUAL FOR COMFLEX 6100 Figure 58: Management – Security Click , [Modify Password] window will pop-up. Figure 59: Modify Password Note: Username cannot be modified. ENU STATUS : 1-0-0 Copyright - refer to title page Page 49 USER MANUAL FOR COMFLEX 6100 Device Reset Select a device, the device information will show. Reset all parameter and alarm settings to factory default. Clear all history alarms Figure 60: Management – Device Reset Note: Device WEB GUI. Reset process will last about 2~4 minutes. For MU monitor reset, users need to re-login PA Reset Only RU has PA reset function Each band can be set separately Figure 61: Management – PA Reset Note: PA will be turned off by software when PA output power or (VSWR) reflected power is exceed the threshold. Users need to reset PA after debugging. Device Info ENU STATUS : 1-0-0 Copyright - refer to title page Page 50 USER MANUAL FOR COMFLEX 6100 Select a device Input Device information here, click Submit. Click here to get the computer time, then click Submit. Figure 62: Management – Device Info Note: Users can input maximum 30 bytes characters in Device Info. Device Scanning Figure 63: Management – Device Scanning Note: This Step is the same as step1 of [Commissioning]. Running scanning, software will allocate an ID to RU so that MU can identify and visit it. ENU STATUS : 1-0-0 Copyright - refer to title page Page 51 USER MANUAL FOR COMFLEX 6100 Device Remove Figure 64: Management – Device Remove Note: If the RU has been scanned and identified by MU, to remove the RU from the system,users must remove this RU on this [Device Remove] page, otherwise, RU will still be shown on the Home page and will trigger optical alarm. Report Users can check the current running status of MU/RU by [Report] function. Step 1: Select a device Step 2: Click [Create] to review the Report Figure 65: Management – Report ENU STATUS : 1-0-0 Copyright - refer to title page Page 52 USER MANUAL FOR COMFLEX 6100 Note: Users can use Chrome and Firefox to review the report. When using Chrome, once you click [Create], the report will be pop-up in a new window. When using Firefox as the browser, users need to set browser applications settings first, then follow the steps shown on the figure above to create the report. Figure 66: Firefox setting (1) Figure 67: Firefox setting (2) Alarm Log In [Alarm Log] page, users can query and export MU and RU history alarms, for facilitating trobuble shouting and monitoring MU/RU alarms. ENU STATUS : 1-0-0 Copyright - refer to title page Page 53 USER MANUAL FOR COMFLEX 6100 Step 2: Click to select a begin date and End date Step 1: Select a device Step 3: Click [Query] to review the log and click [ Export] to load the log on your computer Figure 68: Management – Alarm Log 5.3 COMMISSIONING PROCEDURE To complete the installation and commissioning, users need to follow the steps below. Step 1: Click Menu bar [Commissioning] on home page, a work flow will show up. Figure 69: Commissioning Procedure - Start Step 2: Click ENU STATUS : 1-0-0 to start RU device scan, this step will take about 1 minute. Copyright - refer to title page Page 54 USER MANUAL FOR COMFLEX 6100 Figure 70: Commissioning Procedure – Device Scan Step 3: Click to enter to Params Setting page. Click information and system time. , users can set the device Figure 71: Commissioning Procedure – Params Setting ENU STATUS : 1-0-0 Copyright - refer to title page Page 55 USER MANUAL FOR COMFLEX 6100 Figure 72: Dev Info & Date/Time Dev Info mainly used to record device location and Date/Time provid a time reference. Mouse click the Config Value of Date/Time to auto receive the computer time. NOTE: Make sure all the ANT ports of RUs are connected with dummy load or antenna system before proceeding to step 4. Step 4: Click to enter to MU Calibratiion page after finishing Parems Setting. Select a frequency band that need to calibrate from the table in the middle of the page. Read Tip1 on the left side and click of Tip 1 Input signal to a RF port of RFU which you want to calibrate. Read Tip2 on the left side and enther the input power in the box (Suggested input power 1030dBm). Input power has to be >10dBm for successful calibration. Click Tip of MU calibration finish will show up on the left of the page, and calibration results will show in the table. NOTE: Each RFU needs to be calibrated; click “More” at last step of process to calibrate next RFU. ENU STATUS : 1-0-0 Copyright - refer to title page Page 56 USER MANUAL FOR COMFLEX 6100 Figure 73: Commissioning Procedure – MU Calibration Figure 74: Commissioning Procedure – MU Calibration Finish NOTE1: Calibration is to adjust MU and RU gain to assure system gain is satisfied with the rated gain (20dB for low power system and 27dB for medium power system), if the band have been calibrated, users can click to skip the process; if the band never been calibrated, users click in the step of MU Calibration and RU Calibration, software can still procede to the next step of MU and RU setup, but the system gain will be a little deviation with the rated gain, so the final output power will be not same with the target DL output power. NOTE2: If there are more than one same band access to MU, then each access need to be calibrated in MU Calibration step, while in RU Cablibration step, users only need to calibrate the band one time, because all the same band shares the same PA. Step 5: Click to enter to RU Calibratiion page, refer to step 4 to finish RU calibration. NOTE1: Make sure the ANT port of RU is connected with dummy load or antennas before Calibration. Several RU can be calibrated simultaneously. NOTE2: You can calibrate one RU or calibrate all the RUs at one time. Click “site” in RU table to select all RUs. ENU STATUS : 1-0-0 Copyright - refer to title page Page 57 USER MANUAL FOR COMFLEX 6100 Figure 75: Commissioning Procedure – RU Calibration Figure 76: Commissioning Procedure – RU Calibration Finish Step 6: Click to enter to MU Setup page after finishing RU calibration. Figure 77: Commissioning Procedure – MU Setup ENU STATUS : 1-0-0 Copyright - refer to title page Page 58 USER MANUAL FOR COMFLEX 6100 Click to set band related information. Figure 78: MU Frequency Band Table Three parameters need to be set in this step. Operator Info: record the operator information of this RU unit. RF Switch: Set the RF switch status of this RF unit. DL Input Power: Input Power of the BTS signal access to this RF unit. Note: ComFlex system reaches its rated output power when input power is +10dBm, if DL Input Power is over 10dBm, software will autoadjust the internal attenuator to make RU output power reach rated Power. (Input power range: 10-30dBm). Step 7: Click to enter to RU Setup page after finishing MU setup. Figure 79: Commissioning Procedure – RU Setup Click to set band related information of RU. ENU STATUS : 1-0-0 Copyright - refer to title page Page 59 USER MANUAL FOR COMFLEX 6100 Figure 80: RU Frequency Band Table Two parameters need to be set in this step. RF Switch: Set the RF switch status of Remote Unit. Target DL Output Power: Expected DL output power setting. Note: Rated output power of LRU is 30dBm and MRU is 37dBm, when Target DL Output Power is set less than rated output power, software will auto adjust RU gain to make the RU output power reach the expected Power. Step 8: Click to enter to [Finish] page after finishing RU setup. Click bands. Click if all bands’ clibration is done. to calibrate other Figure 81: Commissioning Procedure – Finish Note: As the system calibration process is calibrated for single channel, so if there is more than one same band input, because of the power superposition, the band total output power will higer than target DL output power after the calibration is complete. The calibration work is mainly to set device to reach it’s theoretical gain, so when there are two or more same bands access into and they have the same input power level, each channel will reach it’s rated ENU STATUS : 1-0-0 Copyright - refer to title page Page 60 USER MANUAL FOR COMFLEX 6100 power, so the total output power will be (input A+gain) + (inputB+gain)+…+(inputN+gain). For example, if there are two 1900MHz bands acess to MU, each has 10dBm input power, the total output power of RU 1900MHz will be 37dBm+37dBm=40dBm. For Multi-channel same band access, 800+850 (which share the same PA) access and 700 Uper C + LowerABC (also shared PA), they all will have power superposition. In this situation, users need to adjust system gain manually; otherwise, the output power will be higher than 32dBm which will trigger alarms (See Chapter 6 for details). Refer to the method below for the gain adjustment: Suppose a band with N independent inputs, each input signal power are all X dBm. Apparently, there exists the following relationship between input and output after finished auto communication on WEB GUI: X dBm + Gain = Rated output power, then the total output power for N channels access is X dBm + Gain + 10*Log(N) = Rated output power + 10*Log(N), so Users need to set 10*Log(N) RFU ATT on WEB GUI for each channel. End of Section ENU STATUS : 1-0-0 Copyright - refer to title page Page 61 USER MANUAL FOR COMFLEX 6100 6 ALARMS AND TROUBLESHOOTING 6.1 ALARMS Alarm List Table 14: MU Alarm List Alarm Condition Over-Temperature Alarm Alarm when equipment temperature is higher than the threshold, otherwise normal; Alarm judgment period: 3 minutes by default; Alarm threshold : 80℃ by default. Alarm when Optical Transmiting power is lower than the threshold, otherwise normal; Alarm judgment period: 3 minutes by default; Alarm threshold: -7dBm by default. Alarm when Optical received power is lower than the threshold, otherwise normal; Alarm judgment period: 3 minutes by default; Alarm threshold: -10dBm by default. Alarm when DL input power is higher than the threshold, otherwise normal; Alarm judgment period: 3 minutes by default; Alarm threshold: 32dBm by default. Optical Tx Alarm Optical Rx Alarm DL Input Power Overload Alarm Alarm List Table 15: RU Alarm List Alarm Condition Alarm status when the external terminals have the same H/L level with alarm level, otherwise normal; Alarm period: 10s by default. Alarm when equipment temperature is higher than the threshold, otherwise normal; Alarm judgment period: 3 minutes by default; Alarm threshold : 80℃ by default. Alarm When optical transmiting power is lower than the threshold, otherwise normal; Alarm judgment period: 3 minutes by default; Alarm threshold: 0dBm by default. Alarm When optical receiving power is lower than the threshold, otherwise normal; Alarm judgment period: 3 minutes by default; Alarm threshold: -14dBm by default. Alarm when any one of the PA Current Alarm,PA Over-temperature Alarm, PA DL output power overload Alarm, Reflection Power Alarm happens, otherwise normal; Alarm judgment period: 3 minutes by default. Alarm when the DL output power is higher than the threshold, otherwise normal; Alarm judgment period: 3 minutes by default; Alarm threshold: 32dBm for LRU, 39dBm for MRU. Alarm when the PA status is off, otherwise normal; Alarm judgment period: 10s by default. Alarm when LNA have problems, otherwise normal; Alarm judgment period: 3 minutes by default. External Alarm Over-Temperature Alarm Optical Tx Alarm Optical Rx Alarm PA Alarm DL Output Overload Alarm Shutdown Alarm LNA Alarm ENU STATUS : 1-0-0 Copyright - refer to title page Page 62 USER MANUAL FOR COMFLEX 6100 6.2 TROUBLESHOOTING Following installation and commissioning, occasional operation tasks to handle alarms may be required: Table 16: MU Alarms Diagnosis Alarm condition Diagnosis DL Input Power Overload Alarm Check device temperature on WEB GUI If device temperature is over threshold, make sure environment temperature is within the envireonment temperature range that MU supported (0~40℃). Apply climatic protection to the system under severe environment. Test MU transmit optical power Replace FOU if transmit optical power is less than -7dBm Use Optical Power Meter to test received optical power If received optical power is lower than -10dBm, test whether RU transmit optical power is normal (3~5dBm) Check if optical loss of fiber link is higher than 6.5dBo Clean fiber connector with absolute ethanol Test DL input power of MU, if it is higher than +33dBm, choose proper coupler to ensure the input power to MU is lower than +33dBm. Alarm condition Diagnosis External Alarm Check to make sure if the external device connected is working normally OverTemperature alarm Optical TX Alarm Optical RX Alarm Table 17: RU Alarms Diagnosis OverTemperature alarm Optical TX Alarm Optical RX Alarm DL PA alarms Check device temperature on WEB GUI If device temperature e is over threshold, make sure environment temperature is within the envireonment temperature range that RU supported (-20~50℃).Apply climatic protection to the system under severe environment. Test RU transmit optical power Replace FOU if transit optical power is less than 0dBm Use Optical Power Meter to test received optical power If received optical power is lower than -14dBm, test whether MU transmit optical power is normal (-4~-2dBm) Check if optical loss of fiber link is higher than 6.5dBo Clean fiber connector with absolute ethanol Check PA Service Status on WEB GUI RU page, If it is [Recovery], reset PA on WEB GUI Management page, then read RU output power: If output power is exceed threshold, need to reduce gain or input power; if output power is normall, check whether antenna port VSWR is too high. If it is [Shutdown], Refer to PA Shutdown Alram DL Output Power Overload Alarm Check if output power is exceed the threshold (32dBm for LRU, 39dBm for MRU) Decrease the gain to reduce the output power PA Shutdown Alarm Make Sure the environment temperature is -20~50℃ Reset PA, if PA service status turns to [Recovery], and then refer to DL PA Alarms. If PA still shutdown, the PA module maybe damaged, please contact with Comba to replace the RU. LNA Alarm Uplink LNA modual damaged, please contact with Comba to replace the RU. End of Section ENU STATUS : 1-0-0 Copyright - refer to title page Page 63 USER MANUAL FOR COMFLEX 6100 7 APPENDICES 7.1 APPENDIX A: TOOLS FOR INSTALLATION AND MAINTENANCE The following tools (not included in package) are required for installation or routine maintenance: Power Drill (for wall mount) Adjustable Wrench (0.31 inch~0.79 inch) Philips Screwdriver Allen wrench (M6) Signal generator support output power 10dB. Site Master ENU STATUS : 1-0-0 Copyright - refer to title page Page 64 USER MANUAL FOR COMFLEX 6100 7.2 APPENDIX B: RMA (RETURN MATERIAL AUTHORIZATION) End of Section End of Document FOR NAM OFFICE EMAIL, PLEASE INSERT: support.us@comba-telecom.com ENU STATUS : 1-0-0 Copyright - refer to title page Page 65 USER MANUAL FOR COMFLEX 6100 ENU STATUS : 1-0-0 Copyright - refer to title page Page 66
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-701 Create Date : 2014:11:19 07:34:17Z Creator Tool : Microsoft® Office Word 2007 Modify Date : 2014:11:19 15:35:30+08:00 Metadata Date : 2014:11:19 15:35:30+08:00 Format : application/pdf Creator : D Shiu Title : Producer : Microsoft® Office Word 2007 Document ID : uuid:06cc9b6c-d22a-412e-a56f-b791485d3dc5 Instance ID : uuid:f2cadfb8-becb-4113-9b96-4694cd25f801 Has XFA : No Page Count : 66 Language : zh-CN Author : D ShiuEXIF Metadata provided by EXIF.tools