  SM-MMN17-C01  NFC Controller Module with Antenna Datasheet Version 1.2 Smart Approach Co., Ltd.  Rm. 5, 3F., No.1, Taiyuan 2nd St., Zhubei City, Hsinchu County 302, Taiwan, R.O.C.  +886-3-5601363 www.smart-approach.com.tw
  SM-MMN17-C01 Datasheet   - 2 - Revision 1.2 October 2016                            Smart Approach Co., Ltd ( S.A. ) retains the right to make changes to its products or specifications to improve performance, reliability or manufacturability. All information in this document, including descriptions of features, functions, performance, technical specifications and availability, is subject to change without notice at any time. While the information furnished herein is held to be accurate and reliable, no responsibility will be assumed by Smart Approach for its use. Furthermore, the information contained herein does not convey to the purchaser of microelectronic devices any license under license under the patent right of any manufacturer. Smart Approach Co., Ltd is a registered trademark. All other products or service names used in this publication are for identification purposes only, and may be trademarks or registered trademarks of their respective companies. All other trademarks or registered trademarks mentioned herein are the property of their respective holders. Feedback on the use of any of the document is welcomed and encouraged by Smart Approach.    Please contact service@smart-approach.com.tw for your feedback or any ordering inquiry.  Please contact support@smart-approach.com.tw for any technical question. This section describes the changes that were implemented in this document. The changes are listed by revision, starting with the most current publication. Revision 1.0   Revision 1.0 of this datasheet was published in December 2014. This was the first publication of the document. Revision 1.1   Updated chapter 2 features, in April 2016. Revision 1.2   Updated chapter 7 outline, in October 2016.
  SM-MMN17-C01 Datasheet   - 3 - Revision 1.2 October 2016                            REVISION HISTORY ............................................................................................................................. -  2  -CONTENTS ........................................................................................................................................... -  3 -FIGURE CONTENTS ............................................................................................................................ -  4  -TABLE CONTENTS .............................................................................................................................. -  4  -1 INTRODUCTION .......................................................................................................................... - 5 -2 PRODUCT OVERVIEW ................................................................................................................ - 6  -2.1 FEATURES .............................................................................................................................. - 6 -2.2 APPLICATION .......................................................................................................................... - 6 -3 FUNCTIONAL DESCRIPTIONS .................................................................................................. - 7 -4 ELECTRICAL SPECIFICATIONS ................................................................................................ - 8 -4.1 PIN DESCRIPTION ................................................................................................................... - 8 -4.2 I2C ADDRESS ......................................................................................................................... - 9 -4.3 TEMPERATURE MAXIMUM RATINGS ..........................................................................................  - 9 -4.4 DC ELECTRICAL PARAMETERS .............................................................................................. - 10 -4.5 ANTENNA SPECIFICATION ...................................................................................................... - 10 -4.6 POWER CONSUMPTION .......................................................................................................... - 11 -4.7 THERMAL PROTECTION .......................................................................................................... - 11 -4.8 SYSTEM POWER MODES ......................................................................................................... - 11 -4.9 RESET AND DOWNLOAD CONCEPT ..........................................................................................  - 12 -5 ORDERING INFORMATION ...................................................................................................... - 13 -6 RELIABILITY VERIFICATION .................................................................................................... -  14  -7 NFC MODULE OUTLINE ........................................................................................................... - 15  -
  SM-MMN17-C01 Datasheet   - 4 - Revision 1.2 October 2016                            Figure 1 Typical Application ................................................................................................. - 6 -Figure 2 Module Block Diagram .......................................................................................... - 7 -Figure 3 Reset via VEN pin ................................................................................................. - 12 -Figure 4 NFC Module Drawing .......................................................................................... - 15 -Figure 5 Module FPC Connection Foot Print ..................................................................... - 16 -Figure 6 FPC Wire Dimension ........................................................................................... - 16 -Table 1 Module Pin Description ........................................................................................... -  8 -Table 2 I2C Address ............................................................................................................. - 9 -Table 3 Temperature Maximum Ratings .............................................................................. - 9 -Table 4 DC Electrical Specification .................................................................................... - 10 -Table 5 Antenna Specifications .......................................................................................... - 10 -Table 6 Current Consumption ............................................................................................ - 11 -Table 7 Thermal Protection ................................................................................................ - 11 -Table 8 System Power Modes Description ........................................................................ - 11 -Table 9 Power Mode Configuration .................................................................................... - 12 -Table 10 Reset Timing ....................................................................................................... - 12 -Table 11 Ordering Information Table .................................................................................. - 13 -Table 12 Reliability Item Table ........................................................................................... - 14 -
  SM-MMN17-C01 Datasheet   - 5 - Revision 1.2 October 2016                            1 Introduction This document consists of descriptions and specifications for both functional and physical aspects of the SM-MMN17-C01 NFC reader / writer module. In addition to the datasheet, Smart Approach maintains and extensive device-specific library of support and collateral materials that you may find useful in your application. Depending upon the Smart Approach device, this library may include:   Presentations highlighting the operational features and specifications of the device to assist in developing your own product road map.   Application notes that provide detailed descriptions of the use of the particular Smart Approach product to solve real-world problems.
  SM-MMN17-C01 Datasheet   - 6 - Revision 1.2 October 2016                            2 Product Overview SM-MMN17-C01 is full featured NFC controllers designed for integration in portable equipment. It is optimized for low power consumption with fully host controllable power states and for small footprint for portable equipment applications.  size-sensitive applications, assures robust performance. The following illustration shows a high-level, generic view of a SM-MMN17-C01 application.   Figure 1 Typical Application 2.1  Features This section Tables key aspects of the SM-MMN17-C01 module functionality and design that distinguish it from similar products:  NXP NPC100   consumption.   Compliant with ISO/IEC 14443 A/B  Compliant with ISO/IEC 15693/18092   Compliant with NFCIP-1, NFCIP-2   Support MIFARE and Felica specifications  Customized antenna pairing  I2C interface  2.2  Application Suggested applications for the SM-MMN17-C01 module include:  NFC writer/ reader   NFC peer to peer controller    NFC identification
  SM-MMN17-C01 Datasheet   - 7 - Revision 1.2 October 2016                            3 Functional Descriptions This section provides detailed information about how SM-MMN17-C01 module works, what configurations and operational features are available. The following illustration shows the primary functional blocks of SM-MMN17-C01 module.   Figure 2 Module Block Diagram  Loop Antenna is Smart Approach customize solution. Antenna matching is also a customize solution. NFC controller includes NXP NPC100 chipset, and has an I2C control interface through the connector to mother board.    Customized Antenna
  SM-MMN17-C01 Datasheet   - 8 - Revision 1.2 October 2016                            4 Electrical Specifications This section provides the DC characteristics, AC characteristics, recommended operating conditions. It includes information on the various timing functions of the module.  4.1  Pin Description The following Table shows the pin description for SM-MMN17-C01 module. The connection ground is internally connected and should be connected to GND on the main board as well.    Table 1 Module Pin Description PIN No.  Name Description Power Reference  P/I/O 1  VBAT +3.3V power supply input  3.3V  P 2  MOD_GND Module Ground  GND  P 3  SWP  SWP data line to UICC/SIM, Input / Output  PMUVCC I/O 4  RFU  Unused pin could be floating  -  - 5  IRQ  Interrupt to host, High: Interrupt; Low: Normal  VDD_IO  O 6  PMUVCC  Power supply to UICC/SIM, input, + 1.8V  1.8V  P 7  I2C_SDA  I2C Data Line (400Kbps)  VDD_IO  I/O 8  I2C_SCL I2C Clock (400Kbps)  VDD_IO  I 9  MOD_GND  Module Ground  GND  P 10  VEN Wake up the module from standby mode or reset the module  VBAT I 11  DWL_REQ  Firmware download control: Active High  VDD_IO  I 12  SIMVCC  The power rail used to power UICC / SIM, output pin  PMUVCC P(O) 13  VBAT +3.3V Power Supply  3.3V  P 14  VDD_IO  +1.8V or +3.3V for host IO reference voltage  1.8V/3.3V    P 15  MOD_GND  Module Ground  GND  P
  SM-MMN17-C01 Datasheet   - 9 - Revision 1.2 October 2016                            4.2  I2C Address SM-MMN17-C01 I2C 7bit address is defined to 0x28. To write data, the module is addressed using 0x50, to read data, the module is addressed using 0x51.  Table 2 I2C Address I2C address (R/W=0, write)  I2C address (R/W=1, read) 0x50  0x51  4.3  Temperature Maximum Ratings Thermal specifications for this module have been modeled using a two-layer test board.  Table 3 Temperature Maximum Ratings Symbol  Definition  Value  Units Min  Max T  Operating Temperature  -20 80   TS Storage Temperature  -40  100
  SM-MMN17-C01 Datasheet   - 10 - Revision 1.2 October 2016                            4.4  DC Electrical Parameters DC Electrical specifications for this module have been modeled using a two-layer test board.  Table 4 DC Electrical Specification Symbol  Definition  Value Units Min  Typ  Max   VBAT Power Supply  3.1 3.3  3.5  Volts IVBAT DC Current      170  mA  4.5  Antenna Specification Antenna specifications for this module have been modeled using a two-layer test board.  Table 5 Antenna Specifications Item Value Unit Note Min  Type  Max DC Resistance  0.5 1  2   AC Impedance   50       Frequency  13.06 13.56 14.06 MHz VSWR <2 Q factor  25  30  35
  SM-MMN17-C01 Datasheet   - 11 - Revision 1.2 October 2016                            4.6  Power Consumption Table 6 Current Consumption Symbol Parameter Conditions Min Typ Max Unit IHPD Hard power down current  VBAT=3.6V, VEN=0V  -  10.5  12   ISTBY Standby state current  VBAT=3.6V -  -  20   IACT Active state current  VBAT=3.6V  -  6  -  mA ITVDD Transmitter supply current  VBAT=3.1V -  30  100  mA IPMUVCC PMUVCC supply  Class B  -  1.5  3   Class C  -  1  2    4.7  Thermal Protection Table 7 Thermal Protection Symbol Parameter Conditions Min  Typ  Max  Unit TOVERTEMP Temperature protection trigger   120  125  130 0C  4.8  System power modes Table 8 System Power Modes Description Mode Description Full power mode The battery supply (VBAT) as well as the pad supply (VDD_IO) is available, all use cases can be executed Low-power mode The pad supply (VDD_IO) is not available. Only the Card Emulation mode use cases via SWP are allowed Power Off mode  The system is not supplied from any source or the system is kept Hard Power Down (HPD)
  SM-MMN17-C01 Datasheet   - 12 - Revision 1.2 October 2016                            Table 9 Power Mode Configuration VBAT VDD_IO  VEN Power mode Off  Off  X  Power Off mode On  X  Off  Power Off mode On  Off  On  Low Power Mode On  On On  Full power mode Note: X: Don t care  4.9  Reset and download concept To enter reset there are 2 ways: - Pulling VEN low (Hard Power Down state) - If VBAT monitor is enabled: lowering VBAT below the monitor threshold (monitor mode, if VEN is kept above 1.1 V) To get out of reset, there are 1 ways: - Pulling VEN high with VBAT above VBAT monitor threshold if enabled   Figure 3 Reset via VEN pin  Table 10 Reset Timing Symbol Parameter Condition  Min  Typ  Max  Unit tRESETVEN VEN pulse width to reset   3       tBOOT Boot time        10  ms
  SM-MMN17-C01 Datasheet   - 13 - Revision 1.2 October 2016                            5 Ordering Information Table 11 Ordering Information Table Order Number  Descriptions SM-MMN17-C01  NFC Controller Module (NXP NPC100) with Antenna Dimension  Module: 26.65x10.00 mm; Antenna Area: 32.00x10.00mm Total Size: 63.65x10.00mm
  SM-MMN17-C01 Datasheet   - 14 - Revision 1.2 October 2016                            6 Reliability Verification Table 12 Reliability Item Table No. Item  Condition  Benchmark Result Qty 1  Low Temperature Storage Test  -40oC  IEC60068-2-1  Pass  5 2  High Temperature Storage Test  80oC, Humidity: 95%  IEC60068-2-78  Pass 5 3  Low Temperature Operation Test  -20oC  IEC60068-2-1  Pass 5 4  High Temperature Operation Test  80oC IEC60068-2-2 Pass 5 5  High Temperature Operation Test  65oC, Humidity: 95%  IEC60068-2-78  Pass 5 6  Salt Test PH: 3.0 ~ 3.2 ,50 , 72 hrs, Density: 5%±1%ASTM B368  Pass 5 7  RoHS  Normal  Compliance  Pass  5 8  HF Normal Compliance Pass  5
  SM-MMN17-C01 Datasheet   - 15 - Revision 1.2 October 2016                            7  NFC Module Outline The following illustration shows the package drawing for SM-MMN17-C01 module. The drawing contains the detail views, dimensions, tolerances, and notes.   Figure 4 NFC Module Drawing
  SM-MMN17-C01 Datasheet   - 16 - Revision 1.2 October 2016                                  Figure 5 Module FPC Connection Foot Print    Figure 6 FPC Wire Dimension
Federal Communication Commission Interference Statement  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:   Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.  FCC Caution:  Any changes or modifications not expressly  approved by the party responsible for compliance could void the user's authority to operate this equipment.  This  transmitter  must  not  be  co-located  or  operating  in  conjunction  with  any other antenna or transmitter.
Radiation Exposure Statement: The  product  is  a  low  power  device  and  its  output  power  is  lower  than  FCC  SAR exemption level. This module can be used with SM-MMN17-C01.  This device is intended only for OEM integrators under the following conditions: 1) The transmitter module may not be co-located with any other transmitter or antenna. The co-transmitting with other radio will need a separate evaluation. 2) Module approval valid only when this module is installed in the tested host “CAX00, CXXXXX-CAX00-XXXXXX-XXXX (X:0~9,A~Z)”.  As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed  IMPORTANT NOTE: In the event that these conditions cannot be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID cannot be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization.  End Product Labeling The final end product must be labeled in a visible area with the following: “Contains FCC ID: GKR-CAX00NFC”. The grantee's FCC ID can be used only when all FCC compliance requirements are met.  Manual Information to the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.  Industry Canada statement  This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:   1) this device may not cause interference, and   2) this device must accept any interference, including interference that may
cause undesired operation of the device.  Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:   1) l'appareil ne doit pas produire de brouillage, et   2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.   This Class B digital apparatus complies with Canadian ICES-003.  Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.   This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except tested built-in radios.    Cet appareil et son antenne ne doivent pas être situés ou fonctionner en conjonction avec une autre antenne ou un autre émetteur, exception faites des radios intégrées qui ont été testées.    This device is intended only for OEM integrators under the following conditions: (For module device use) 1) The transmitter module may not be co-located with any other transmitter or antenna. As long as one condition above is met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed.  Cet appareil est conçu uniquement pour les intégrateurs OEM dans les conditions suivantes: (Pour utilisation de dispositif module) 1) Le module émetteur peut ne pas être coïmplanté avec un autre émetteur ou antenne. Tant qu'une condition ci-dessus est remplie, un autre test de l'émetteur n'est pas nécessaire. Toutefois, l'intégrateur OEM est toujours responsable de tester leur produit final pour toutes les exigences de conformité supplémentaires requises avec ce module installé.
IMPORTANT NOTE: In  the  event  that  these  conditions  cannot  be  met  (for  example  certain  laptop configurations  or  co-location  with  another  transmitter),  then  the  Canada authorization is no longer considered valid and the IC ID cannot be used on the final product.  In  these  circumstances,  the  OEM  integrator  will  be  responsible  for re-evaluating  the  end  product  (including  the  transmitter)  and  obtaining  a  separate Canada authorization. NOTE IMPORTANTE: Dans le cas où ces conditions ne peuvent être satisfaites (par exemple pour certaines configurations d'ordinateur portable ou de certaines co-localisation avec un autre émetteur), l'autorisation du Canada n'est plus considéré comme valide et l'ID IC ne peut pas être utilisé sur le produit final. Dans ces circonstances, l'intégrateur OEM sera chargé de réévaluer le produit final (y compris l'émetteur) et l'obtention d'une autorisation distincte au Canada. End Product Labeling   The product can be kept as  far as possible from the user body or set the device to lower  output  power  if  such  function  is  available.  The  final  end  product  must  be labeled in a visible area with the following: “Contains IC: 2533B-CAX00NFC”.   Plaque signalétique du produit final L'appareil peut être conservé aussi loin que possible du corps de l'utilisateur ou que le dispositif est réglé sur la puissance de sortie la plus faible si une telle fonction est disponible.  Le  produit  final  doit  être  étiqueté  dans  un  endroit  visible  avec l'inscription suivante: "Contient des IC: 2533B-CAX00NFC". Manual Information To the End User The  OEM  integrator  has  to  be  aware  not  to  provide  information  to  the  end  user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The  end  user  manual  shall  include  all  required  regulatory  information/warning  as show in this manual. Manuel d'information à l'utilisateur final L'intégrateur  OEM  doit  être  conscient  de  ne  pas  fournir  des  informations  à
l'utilisateur final quant à  la  façon  d'installer ou de supprimer ce module RF dans le manuel de l'utilisateur du produit final qui intègre ce module. Le  manuel  de  l'utilisateur  final  doit  inclure  toutes  les  informations  réglementaires requises et avertissements comme indiqué dans ce manuel.

User Manual (Module)

  SM-MMN17-C01  NFC Controller Module with Antenna Datasheet Version 1.2 Smart Approach Co., Ltd.  Rm. 5, 3F., No.1, Taiyuan 2nd St., Zhubei City, Hsinchu County 302, Taiwan, R.O.C.  +886-3-5601363 www.smart-approach.com.tw
  SM-MMN17-C01 Datasheet   - 2 - Revision 1.2 October 2016                            Smart Approach Co., Ltd ( S.A. ) retains the right to make changes to its products or specifications to improve performance, reliability or manufacturability. All information in this document, including descriptions of features, functions, performance, technical specifications and availability, is subject to change without notice at any time. While the information furnished herein is held to be accurate and reliable, no responsibility will be assumed by Smart Approach for its use. Furthermore, the information contained herein does not convey to the purchaser of microelectronic devices any license under license under the patent right of any manufacturer. Smart Approach Co., Ltd is a registered trademark. All other products or service names used in this publication are for identification purposes only, and may be trademarks or registered trademarks of their respective companies. All other trademarks or registered trademarks mentioned herein are the property of their respective holders. Feedback on the use of any of the document is welcomed and encouraged by Smart Approach.    Please contact service@smart-approach.com.tw for your feedback or any ordering inquiry.  Please contact support@smart-approach.com.tw for any technical question. This section describes the changes that were implemented in this document. The changes are listed by revision, starting with the most current publication. Revision 1.0   Revision 1.0 of this datasheet was published in December 2014. This was the first publication of the document. Revision 1.1   Updated chapter 2 features, in April 2016. Revision 1.2   Updated chapter 7 outline, in October 2016.
  SM-MMN17-C01 Datasheet   - 3 - Revision 1.2 October 2016                            REVISION HISTORY ............................................................................................................................. -  2  -CONTENTS ........................................................................................................................................... -  3 -FIGURE CONTENTS ............................................................................................................................ -  4  -TABLE CONTENTS .............................................................................................................................. - 4 -1 INTRODUCTION .......................................................................................................................... - 5 -2 PRODUCT OVERVIEW ................................................................................................................ - 6  -2.1 FEATURES .............................................................................................................................. - 6 -2.2 APPLICATION .......................................................................................................................... - 6 -3 FUNCTIONAL DESCRIPTIONS .................................................................................................. - 7 -4 ELECTRICAL SPECIFICATIONS ................................................................................................ - 8 -4.1 PIN DESCRIPTION ................................................................................................................... - 8 -4.2 I2C ADDRESS ......................................................................................................................... - 9 -4.3 TEMPERATURE MAXIMUM RATINGS ..........................................................................................  - 9 -4.4 DC ELECTRICAL PARAMETERS .............................................................................................. - 10 -4.5 ANTENNA SPECIFICATION ...................................................................................................... - 10 -4.6 POWER CONSUMPTION .......................................................................................................... - 11 -4.7 THERMAL PROTECTION .......................................................................................................... - 11 -4.8 SYSTEM POWER MODES ......................................................................................................... - 11 -4.9 RESET AND DOWNLOAD CONCEPT ..........................................................................................  - 12 -5 ORDERING INFORMATION ...................................................................................................... - 13 -6 RELIABILITY VERIFICATION .................................................................................................... -  14  -7 NFC MODULE OUTLINE ........................................................................................................... - 15  -
  SM-MMN17-C01 Datasheet   - 4 - Revision 1.2 October 2016                            Figure 1 Typical Application ................................................................................................. - 6 -Figure 2 Module Block Diagram .......................................................................................... - 7 -Figure 3 Reset via VEN pin ................................................................................................. - 12 -Figure 4 NFC Module Drawing .......................................................................................... - 15 -Figure 5 Module FPC Connection Foot Print ..................................................................... - 16 -Figure 6 FPC Wire Dimension ........................................................................................... - 16 -Table 1 Module Pin Description ........................................................................................... -  8  -Table 2 I2C Address ............................................................................................................. - 9 -Table 3 Temperature Maximum Ratings .............................................................................. - 9 -Table 4 DC Electrical Specification .................................................................................... - 10 -Table 5 Antenna Specifications .......................................................................................... - 10 -Table 6 Current Consumption ............................................................................................ - 11 -Table 7 Thermal Protection ................................................................................................ - 11 -Table 8 System Power Modes Description ........................................................................ - 11 -Table 9 Power Mode Configuration .................................................................................... - 12 -Table 10 Reset Timing ....................................................................................................... - 12 -Table 11 Ordering Information Table .................................................................................. - 13 -Table 12 Reliability Item Table ........................................................................................... - 14 -
  SM-MMN17-C01 Datasheet   - 5 - Revision 1.2 October 2016                            1 Introduction This document consists of descriptions and specifications for both functional and physical aspects of the SM-MMN17-C01 NFC reader / writer module. In addition to the datasheet, Smart Approach maintains and extensive device-specific library of support and collateral materials that you may find useful in your application. Depending upon the Smart Approach device, this library may include:   Presentations highlighting the operational features and specifications of the device to assist in developing your own product road map.   Application notes that provide detailed descriptions of the use of the particular Smart Approach product to solve real-world problems.
  SM-MMN17-C01 Datasheet   - 6 - Revision 1.2 October 2016                            2 Product Overview SM-MMN17-C01 is full featured NFC controllers designed for integration in portable equipment. It is optimized for low power consumption with fully host controllable power states and for small footprint for portable equipment applications.  size-sensitive applications, assures robust performance. The following illustration shows a high-level, generic view of a SM-MMN17-C01 application.   Figure 1 Typical Application 2.1  Features This section Tables key aspects of the SM-MMN17-C01 module functionality and design that distinguish it from similar products:  NXP NPC100   consumption.   Compliant with ISO/IEC 14443 A/B  Compliant with ISO/IEC 15693/18092   Compliant with NFCIP-1, NFCIP-2   Support MIFARE and Felica specifications  Customized antenna pairing  I2C interface  2.2  Application Suggested applications for the SM-MMN17-C01 module include:  NFC writer/ reader   NFC peer to peer controller    NFC identification
  SM-MMN17-C01 Datasheet   - 7 - Revision 1.2 October 2016                            3 Functional Descriptions This section provides detailed information about how SM-MMN17-C01 module works, what configurations and operational features are available. The following illustration shows the primary functional blocks of SM-MMN17-C01 module.   Figure 2 Module Block Diagram  Loop Antenna is Smart Approach customize solution. Antenna matching is also a customize solution. NFC controller includes NXP NPC100 chipset, and has an I2C control interface through the connector to mother board.    Customized Antenna
  SM-MMN17-C01 Datasheet   - 8 - Revision 1.2 October 2016                            4 Electrical Specifications This section provides the DC characteristics, AC characteristics, recommended operating conditions. It includes information on the various timing functions of the module.  4.1  Pin Description The following Table shows the pin description for SM-MMN17-C01 module. The connection ground is internally connected and should be connected to GND on the main board as well.    Table 1 Module Pin Description PIN No.  Name Description Power Reference  P/I/O 1  VBAT +3.3V power supply input  3.3V  P 2  MOD_GND Module Ground  GND  P 3  SWP  SWP data line to UICC/SIM, Input / Output  PMUVCC I/O 4  RFU  Unused pin could be floating  -  - 5  IRQ  Interrupt to host, High: Interrupt; Low: Normal  VDD_IO  O 6  PMUVCC  Power supply to UICC/SIM, input, + 1.8V  1.8V  P 7  I2C_SDA  I2C Data Line (400Kbps)  VDD_IO  I/O 8  I2C_SCL I2C Clock (400Kbps)  VDD_IO  I 9  MOD_GND  Module Ground  GND  P 10  VEN Wake up the module from standby mode or reset the module  VBAT I 11  DWL_REQ  Firmware download control: Active High  VDD_IO  I 12  SIMVCC  The power rail used to power UICC / SIM, output pin  PMUVCC P(O) 13  VBAT +3.3V Power Supply  3.3V  P 14  VDD_IO  +1.8V or +3.3V for host IO reference voltage  1.8V/3.3V    P 15  MOD_GND  Module Ground  GND  P
  SM-MMN17-C01 Datasheet   - 9 - Revision 1.2 October 2016                            4.2  I2C Address SM-MMN17-C01 I2C 7bit address is defined to 0x28. To write data, the module is addressed using 0x50, to read data, the module is addressed using 0x51.  Table 2 I2C Address I2C address (R/W=0, write)  I2C address (R/W=1, read) 0x50  0x51  4.3  Temperature Maximum Ratings Thermal specifications for this module have been modeled using a two-layer test board.  Table 3 Temperature Maximum Ratings Symbol  Definition  Value  Units Min  Max T  Operating Temperature  -20 80   TS Storage Temperature  -40  100
  SM-MMN17-C01 Datasheet   - 10 - Revision 1.2 October 2016                            4.4  DC Electrical Parameters DC Electrical specifications for this module have been modeled using a two-layer test board.  Table 4 DC Electrical Specification Symbol  Definition  Value Units Min  Typ  Max   VBAT Power Supply  3.1 3.3  3.5  Volts IVBAT DC Current      170  mA  4.5  Antenna Specification Antenna specifications for this module have been modeled using a two-layer test board.  Table 5 Antenna Specifications Item Value Unit Note Min  Type  Max DC Resistance  0.5 1  2   AC Impedance   50       Frequency  13.06 13.56 14.06 MHz VSWR <2 Q factor  25  30  35
  SM-MMN17-C01 Datasheet   - 11 - Revision 1.2 October 2016                            4.6  Power Consumption Table 6 Current Consumption Symbol Parameter Conditions Min Typ Max Unit IHPD Hard power down current  VBAT=3.6V, VEN=0V  -  10.5  12   ISTBY Standby state current  VBAT=3.6V -  -  20   IACT Active state current  VBAT=3.6V  -  6  -  mA ITVDD Transmitter supply current  VBAT=3.1V -  30  100  mA IPMUVCC PMUVCC supply  Class B  -  1.5  3   Class C  -  1  2    4.7  Thermal Protection Table 7 Thermal Protection Symbol Parameter Conditions Min  Typ  Max  Unit TOVERTEMP Temperature protection trigger   120  125  130 0C  4.8  System power modes Table 8 System Power Modes Description Mode Description Full power mode The battery supply (VBAT) as well as the pad supply (VDD_IO) is available, all use cases can be executed Low-power mode The pad supply (VDD_IO) is not available. Only the Card Emulation mode use cases via SWP are allowed Power Off mode  The system is not supplied from any source or the system is kept Hard Power Down (HPD)
  SM-MMN17-C01 Datasheet   - 12 - Revision 1.2 October 2016                            Table 9 Power Mode Configuration VBAT VDD_IO  VEN Power mode Off  Off  X  Power Off mode On  X  Off  Power Off mode On  Off  On  Low Power Mode On  On On  Full power mode Note: X: Don t care  4.9  Reset and download concept To enter reset there are 2 ways: - Pulling VEN low (Hard Power Down state) - If VBAT monitor is enabled: lowering VBAT below the monitor threshold (monitor mode, if VEN is kept above 1.1 V) To get out of reset, there are 1 ways: - Pulling VEN high with VBAT above VBAT monitor threshold if enabled   Figure 3 Reset via VEN pin  Table 10 Reset Timing Symbol Parameter Condition  Min  Typ  Max  Unit tRESETVEN VEN pulse width to reset   3       tBOOT Boot time        10  ms
  SM-MMN17-C01 Datasheet   - 13 - Revision 1.2 October 2016                            5 Ordering Information Table 11 Ordering Information Table Order Number  Descriptions SM-MMN17-C01  NFC Controller Module (NXP NPC100) with Antenna Dimension  Module: 26.65x10.00 mm; Antenna Area: 32.00x10.00mm Total Size: 63.65x10.00mm
  SM-MMN17-C01 Datasheet   - 14 - Revision 1.2 October 2016                            6 Reliability Verification Table 12 Reliability Item Table No. Item  Condition  Benchmark Result Qty 1  Low Temperature Storage Test  -40oC  IEC60068-2-1  Pass  5 2  High Temperature Storage Test  80oC, Humidity: 95%  IEC60068-2-78  Pass 5 3  Low Temperature Operation Test  -20oC  IEC60068-2-1  Pass 5 4  High Temperature Operation Test  80oC IEC60068-2-2 Pass 5 5  High Temperature Operation Test  65oC, Humidity: 95%  IEC60068-2-78  Pass 5 6  Salt Test PH: 3.0 ~ 3.2 ,50 , 72 hrs, Density: 5%±1%ASTM B368  Pass 5 7  RoHS  Normal  Compliance  Pass  5 8  HF Normal Compliance Pass  5
  SM-MMN17-C01 Datasheet   - 15 - Revision 1.2 October 2016                            7  NFC Module Outline The following illustration shows the package drawing for SM-MMN17-C01 module. The drawing contains the detail views, dimensions, tolerances, and notes.   Figure 4 NFC Module Drawing
  SM-MMN17-C01 Datasheet   - 16 - Revision 1.2 October 2016                                  Figure 5 Module FPC Connection Foot Print    Figure 6 FPC Wire Dimension
Federal Communication Commission Interference Statement  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:   Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.  FCC Caution:  Any changes or modifications not  expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.  This  transmitter  must  not  be  co-located  or  operating  in  conjunction  with  any other antenna or transmitter.
Radiation Exposure Statement: The  product  is  a  low  power  device  and  its  output  power  is  lower  than  FCC  SAR exemption level. This module can be used with SM-MMN17-C01.  This device is intended only for OEM integrators under the following conditions: 1) The transmitter module may not be co-located with any other transmitter or antenna. The co-transmitting with other radio will need a separate evaluation. 2) Module approval valid only when this module is installed in the tested host “CAXA0, CXXXXX-CAXA0-XXXXXX-XXXX (X:0~9,A~Z)”.  As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed  IMPORTANT NOTE: In the event that these conditions cannot be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID cannot be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization.  End Product Labeling The final end product must be labeled in a visible area with the following: “Contains FCC ID: GKR-CAX00NFC”. The grantee's FCC ID can be used only when all FCC compliance requirements are met.  Manual Information to the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.  Industry Canada statement  This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:   1) this device may not cause interference, and   2) this device must accept any interference, including interference that may
cause undesired operation of the device.  Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:   1) l'appareil ne doit pas produire de brouillage, et   2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.   This Class B digital apparatus complies with Canadian ICES-003.  Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.   This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except tested built-in radios.    Cet appareil et son antenne ne doivent pas être situés ou fonctionner en conjonction avec une autre antenne ou un autre émetteur, exception faites des radios intégrées qui ont été testées.    This device is intended only for OEM integrators under the following conditions: (For module device use) 1) The transmitter module may not be co-located with any other transmitter or antenna. As long as one condition above is met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed.  Cet appareil est conçu uniquement pour les intégrateurs OEM dans les conditions suivantes: (Pour utilisation de dispositif module) 1) Le module émetteur peut ne pas être coïmplanté avec un autre émetteur ou antenne. Tant qu'une condition ci-dessus est remplie, un autre test de l'émetteur n'est pas nécessaire. Toutefois, l'intégrateur OEM est toujours responsable de tester leur produit final pour toutes les exigences de conformité supplémentaires requises avec ce module installé.
IMPORTANT NOTE: In  the  event  that  these  conditions  cannot  be  met  (for  example  certain  laptop configurations  or  co-location  with  another  transmitter),  then  the  Canada authorization is no longer considered valid and the IC ID cannot be used on the final product.  In  these  circumstances,  the  OEM  integrator  will  be  responsible  for re-evaluating  the  end  product  (including  the  transmitter)  and  obtaining  a  separate Canada authorization. NOTE IMPORTANTE: Dans le cas où ces conditions ne peuvent être satisfaites (par exemple pour certaines configurations d'ordinateur portable ou de certaines co-localisation avec un autre émetteur), l'autorisation du Canada n'est plus considéré comme valide et l'ID IC ne peut pas être utilisé sur le produit final. Dans ces circonstances, l'intégrateur OEM sera chargé de réévaluer le produit final (y compris l'émetteur) et l'obtention d'une autorisation distincte au Canada. End Product Labeling   The product can be kept as  far as possible from the user body or set the device to lower  output  power  if  such  function  is  available.  The  final  end  product  must  be labeled in a visible area with the following: “Contains IC: 2533B-CAX00NFC”.   Plaque signalétique du produit final L'appareil peut être conservé aussi loin que possible du corps de l'utilisateur ou que le dispositif est réglé sur la puissance de sortie la plus faible si une telle fonction est disponible.  Le  produit  final  doit  être  étiqueté  dans  un  endroit  visible  avec l'inscription suivante: "Contient des IC: 2533B-CAX00NFC". Manual Information To the End User The  OEM  integrator  has  to  be  aware  not  to  provide  information  to  the  end  user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The  end  user  manual  shall  include  all  required  regulatory  information/warning  as show in this manual. Manuel d'information à l'utilisateur final L'intégrateur  OEM  doit  être  conscient  de  ne  pas  fournir  des  informations  à
l'utilisateur final quant à  la  façon  d'installer ou de supprimer ce module RF dans le manuel de l'utilisateur du produit final qui intègre ce module. Le  manuel  de  l'utilisateur  final  doit  inclure  toutes  les  informations  réglementaires requises et avertissements comme indiqué dans ce manuel.