 indoor access pointLast Updated: 30/03/16Specications Chipset Board CPU: Qualcomm Atheros AR9344 560MHz (2.4GHz)Radio Card: Qualcomm Atheros QCA9882 (5GHz)System Memory 128MB DDR2NOR Flash 16MBAntenna 2.4GHz: 2x External 2dBi Rubber Duck Omni antenna5GHz: 2x External 2dBi Rubber Duck Omni antennaInterface 2x Gigabit Ethernet Port (Auto MDI-X)1x JTAG 14 Pin Connector11x Serial Port 4 Pin Connector1Reset Button YesLED Indicators: Power LED, LAN Activity, 4x Signal IndicatorDC PowerPower Consumption 10.5W (Max)Operating System Compex OSRoHS Compliance YesEnvironmental Temperature: Operating: -20ºC to 70ºC, Storage: -40ºC to 90ºCHumidity (non-condensing): Operating: 5% to 95%, Storage: Max. 90%Dimensions 129 x 129 x 51 mmOther Features Surge Suppressor, Watchdog Timer1. These features can only be accessed on the Embedded Board.KEY FEATURES• Qualcomm Atheros 560MHz Processor AR9344• IEEE 802.11ac/a/b/g/n compliant • 2.4GHz and 5GHz concurrent radios• 2.4GHz 24dBm and 5GHz 24dBm aggregate power• Data rates of up to 867Mbps in 802.11ac 80MHz channels• Enhanced sensitivity performance• 2x External 2dBi 2.4GHz Rubber Duck Omni Antennas• 2x External 2dBi 5GHz Rubber Duck Omni Antennas• Antenna Alignment LEDsSupport wall mountingAPPLICATIONS• Dual Band concurrent 802.11ac + 802.11b/g/n Access Point • Single Band 802.11ac/a or 802.11b/g/n Access Point•Dual Band 2x2 MIMO 802.11ac/a/b/g/n Versatile Indoor Access Point560MHz CPU / 2.4GHz 300Mbps / 5GHz 867MbpsMIMO New Series      1x DC Jack Connector: 12-24V (LV version)•   Model: MMN344LV-A
 indoor access point2Compex Systems Pte Ltd | www.compex.com.sg | (+65) 6286 2086 | sales@compex.com.sg | Last Updated: 30/03/16 WH SY HBCopyright © Compex Systems. All rights reserved. COMPEX and the COMPEX logo, are registered trademarks of Compex Inc.Atheros and other trademarks are properties of their respective owners. While every effort is made to ensure the information is accurate, Compex does not accept liability for any errors or mistakes that may arise. All specifications are subject to change without notice.RF Performance  Table On-board Radio (WPJ344)Data Rate TX Power  Tolerance2.4GHz802.11b1Mbps 20dBm ±2dB2Mbps 20dBm ±2dB5.5Mbps 20dBm ±2dB11Mbps 20dBm ±2dB2.4GHz802.11g6Mbps 13dBm ±2dB9Mbps 13dBm ±2dB12Mbps 13dBm ±2dB18Mbps 13dBm ±2dB24Mbps 13dBm ±2dB36Mbps 12dBm ±2dB48Mbps 10dBm ±2dB54Mbps 9dBm ±2dB2.4GHz802.11nHT20MCS 0 13dBm ±2dBMCS 1 13dBm ±2dBMCS 2 12dBm ±2dBMCS 3 12dBm ±2dBMCS 4 11dBm ±2dBMCS 5 10dBm ±2dBMCS 6 10dBm ±2dBMCS 7 09dBm ±2dB2.4GHz802.11nHT40MCS 0 13dBm ±2dBMCS 1 13dBm ±2dBMCS 2 12dBm ±2dBMCS 3 12dBm ±2dBMCS 4 11dBm ±2dBMCS 5 10dBm ±2dBMCS 6 10dBm ±2dBMCS 7 10dBm ±2dBData Rate RX Specifications Sensitivity Tolerance2.4GHz802.11b1Mbps -95dBm ±2dB2Mbps -94dBm ±2dB5.5Mbps -92dBm ±2dB11Mbps -90dBm ±2dB2.4GHz802.11g6Mbps -94dBm ±2dB9Mbps -93dBm ±2dB12Mbps -93dBm ±2dB18Mbps -90dBm ±2dB24Mbps -90dBm ±2dB36Mbps -85dBm ±2dB48Mbps -81dBm ±2dB54Mbps -79dBm ±2dB2.4GHz802.11nHT20MCS 0 -93dBm ±2dBMCS 1 -91dBm ±2dBMCS 2 -89dBm ±2dBMCS 3 -84dBm ±2dBMCS 4 -82dBm ±2dBMCS 5 -79dBm ±2dBMCS 6 -79dBm ±2dBMCS 7 -75dBm ±2dB2.4GHz802.11nHT40MCS 0 -90dBm ±2dBMCS 1 -87dBm ±2dBMCS 2 -84dBm ±2dBMCS 3 -83dBm ±2dBMCS 4 -81dBm ±2dBMCS 5 -79dBm ±2dBMCS 6 -78dBm ±2dBMCS 7 -74dBm ±2dB
 indoor access point3Compex Systems Pte Ltd | www.compex.com.sg | (+65) 6286 2086 | sales@compex.com.sg | Last Updated: 30/03/16 WH SY HBCopyright © Compex Systems. All rights reserved. COMPEX and the COMPEX logo, are registered trademarks of Compex Inc.Atheros and other trademarks are properties of their respective owners. While every effort is made to ensure the information is accurate, Compex does not accept liability for any errors or mistakes that may arise. All specifications are subject to change without notice.RF Performance  Table Wireless Module (WLE600VX)Data Rate TX Power  Tolerance5GHz802.11a6-24Mbps 19dBm ±2dB36Mbps 19dBm ±2dB48Mbps 18dBm ±2dB54Mbps ±2dB5GHz802.11n/acHT20MCS 0 ±2dBMCS 1 ±2dBMCS 2 ±2dBMCS 3 ±2dBMCS 4 ±2dBMCS 5 17dBm ±2dBMCS 6 16dBm ±2dBMCS 7 ±2dBMCS 8 ±2dB5GHz802.11n/acHT40MCS 0 ±2dBMCS 1 ±2dBMCS 2 ±2dBMCS 3 ±2dBMCS 4 ±2dBMCS 5 16dBm ±2dBMCS 6 15dBm ±2dBMCS 7 ±2dBMCS 8 ±2dBMCS 9 ±2dB5GHz802.11acHT80MCS 0 ±2dBMCS 1 ±2dBMCS 2 ±2dBMCS 3 ±2dBMCS 4 ±2dBMCS 5 16dBm ±2dBMCS 6 15dBm ±2dBMCS 7 ±2dBMCS 8 ±2dBMCS 9 ±2dBData Rate RX Specifications Sensitivity Tolerance5GHz802.11a6Mbps -94dBm ±2dB36Mbps -86dBm ±2dB48Mbps -82dBm ±2dB54Mbps -80dBm ±2dB5GHz802.11n/acHT20MCS 0 -93dBm ±2dBMCS 1 -91dBm ±2dBMCS 2 -90dBm ±2dBMCS 3 -85dBm ±2dBMCS 4 -82dBm ±2dBMCS 5 -78dBm ±2dBMCS 6 -77dBm ±2dBMCS 7 -75dBm ±2dBMCS 8 -73dBm ±2dB5GHz802.11n/acHT40MCS 0 -93dBm ±2dBMCS 1 -91dBm ±2dBMCS 2 -90dBm ±2dBMCS 3 -85dBm ±2dBMCS 4 -82dBm ±2dBMCS 5 -78dBm ±2dBMCS 6 -77dBm ±2dBMCS 7 -75dBm ±2dBMCS 8 -73dBm ±2dBMCS 9 -71dBm ±2dB5GHz802.11acHT80MCS 0 -89dBm ±2dBMCS 1 -88dBm ±2dBMCS 2 -85dBm ±2dBMCS 3 -81dBm ±2dBMCS 4 -79dBm ±2dBMCS 5 -75dBm ±2dBMCS 6 -74dBm ±2dBMCS 7 -72dBm ±2dBMCS 8 -70dBm ±2dBMCS 9 -68dBm ±2dB16dBm19dBm18dBm18dBm14dBm13dBm18dBm17dBm17dBm14dBm13dBm13dBm18dBm18dBm18dBm17dBm17dBm14dBm13dBm13dBm22dBm22dBm21dBm21dBm
 indoor access point4Compex Systems Pte Ltd | www.compex.com.sg | (+65) 6286 2086 | sales@compex.com.sg | Last Updated: 30/03/16 WH SY HBCopyright © Compex Systems. All rights reserved. COMPEX and the COMPEX logo, are registered trademarks of Compex Inc.Atheros and other trademarks are properties of their respective owners. While every effort is made to ensure the information is accurate, Compex does not accept liability for any errors or mistakes that may arise. All specifications are subject to change without notice.RF Performance InformationScan Surface Direct Far FieldNo. of Theta 361No. of Phi: 2Theta (2-way) 360 degreePSI (1/2 way) 180 degreeFrequency 2.400 - 5.500 GHzPolarization LinearAUT Probe Separation 70.87Reference Power -51.56 dBFar Field Patterns for 2.400 GHz FrequencyFar Field Patterns for 5.500 GHz Frequency
 indoor access point5Compex Systems Pte Ltd | www.compex.com.sg | (+65) 6286 2086 | sales@compex.com.sg | Last Updated: 30/03/16 WH SY HBCopyright © Compex Systems. All rights reserved. COMPEX and the COMPEX logo, are registered trademarks of Compex Inc.Atheros and other trademarks are properties of their respective owners. While every effort is made to ensure the information is accurate, Compex does not accept liability for any errors or mistakes that may arise. All specifications are subject to change without notice.Dimensional Drawing
Federal Communications Commission (FCC) Interference Statement    This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.      These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  in  a  residential installation. This equipment generate, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.    However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:       Reorient or relocate the receiving antenna.    Increase the separation between the equipment and receiver.    Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.    Consult the dealer or an experienced radio/TV technician for help.      This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:   (1)    This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.      RF exposure warning      This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.   This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.