Concealite Life Safety SS2000 Sensor Control Switch User Manual SpaceStation2000 Installation Final3

Concealite Life Safety Products Sensor Control Switch SpaceStation2000 Installation Final3

Users Manual

þ
þDo not let power supply cords touch hot surfaces.
þDo not mount units where they will be exposed to direct sunlight, radiators, gas
or electric heaters. Prolonged exposure to temperatures exceeding 95 degrees
Fahrenheit may reduce battery life and void warranty.
þEquipment should be mounted securely in locations and at heights where it will
not be readily subjected to tampering by unauthorized personnel.
þThe use of accessory equipment not recommended by the MANUFACTURER
may cause an unsafe condition.
þThe AC voltage rating of this equipment is specified on the product label. Do not
connect equipment to any other voltage.
þDo not use this equipment for other than its intended purpose.
þServicing of this equipment should be performed by qualified service personnel.
TECHNICAL DATA
Model:
Ac Supply Voltage: 120/277 Volts (+/- 10%)
Maximum Load: 120v/400w 230v/1000w 277v/1200w Maximum Ballast Load
Operating Voltage: 50/60hz, 120-277v +/- 10%
Switched Power: 400w/1000w/1200w
Standby Power: 0.6w (standby), 1.2w (operation)
10 / 30 / 50 / 75 100%, Can Be Customized
Hold Time: 5s / 30s / 180s /300s /15min / 25min, Can Be Customized
Daylight Threshold OPTIONAL: 20FC - 300FC Daylight / Twilight / Darkness,
Can Be Customized
Sensor Principle: Microwave Motion Detector
Microwave Frequency: 5.8 Ghz +/- 75mhz
Microwave Power: <1mw
Detection Range: Max. (0 X H): 8m X 10m
Detection Angle: 02° 150°
Mounting Height: 0.5 - 100m
Operating Temperature: -35°c `- +70°c
IP Rating: IP 20 (mounting inside a lamp); IP 65 (mounting in special box)
Do not use outdoors.
TM
Installation Instructions
Copyright© Concealite Life Safety Products. All Rights Reserved. Specifications Subject to Change.
Please Save These Instructions
SpaceStation Occupancy Lighting Control System
!Important Safeguards
Read and Follow All Safety Instructions
Limited Warranty
All Concealite fixtures are tested and
are guaranteed to be free from
defective materials and workmanship
for a period of three years from date of
shipment under normal operations and
proper use. Correction of all defects
shall be by replacement or repair (at
our discretion) and shall constitute
fulfillment of all manufacturer's
obligations. We will not allow any
charge for labor, materials, etc. that
does not have our written approval
before the work is begun. Damage
incurring in handling or in transit are not
covered by this guarantee. Any other
warranty, expressed or implied, is
hereby void. Modifications to the
product or failure to follow installation
instructions will void the warranty.
Index
1 Important Safeguards
2Sensor Mounting
3Sensor Adjustments
4New Construction/Retrofit
5 Single Wiring
6 Multiple Wiring
7 Adjustable Remote Mounting (ARM)
8 Troubleshooting
Phone: 605.542.4444 concealite.com
SpaceStation
TM
GREEN TECHNOLO GY
SpaceStation sensors can
be configured to operate
with any number of
sensors and control any
number of lighting circuits
as one system for any
sized room application.
v.092611–SS
SS2000
Step 1: Sensor Mounting
A. Determine mounting location within room or
area to be covered. Center the sensor within
the center of the room/area when possible.
Loosen front knobs.
B. Slide to adjust the four (4) room control panels
to the distance indicated to match the distance in
feet between the sensor and each of the room
wall (to allow activation from any movement within
that room area).
Loosen Front Knobs to Slide Panels
Slide All Four Panels to the Match the Distance
in Feet Between Sensor and Room Walls
Instructions
SpaceStation
i
2
TM
Phone: 605.542.4444
INSTALLATION | Sensor Mounting
WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to
ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published
installation instructions or any modifications to the product may damage the unit and will void the warranty.
Adjustable Range Control Panels (RCP)
controls exact cut off range of each room
ROOM WIDTH
ROOM LENGTH
Room Area Range Coverage
at Sensitivity % Setting
Ceiling
Height
8 Feet
10% 35% 50% 75% 100%
10 Feet
12 Feet
7'
x
7'
8'
x
8'
9'
x
9'
12'
x
12'
20'
x
20'
10'
x
10'
13'
x
13'
17'
x
17'
22'
x
22'
9'
x
9'
12'
x
12'
20'
x
20'
25'
x
25'
9'
x
9'
8'
x
8'
Area Sensitivity Adjustment (SpaceStation Centered in Room)
Note: Maximum 60' Height Provides Maximum Range Coverage to 50 x 50 Feet
v.092611–SS
3
TM
Phone: 605.542.4444
INSTALLATION | Sensor Adjustments
WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to
ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published
installation instructions or any modifications to the product may damage the unit and will void the warranty.
Instructions
SpaceStation
i
STEP 2: SENSOR ADJUSTMENTS
A. Detection Area
Detection are can be reduced by selecting
the combination on the DIP switches to fit
precisely for each specific application.
B. Hold Time
Hold-time means the time period you
would like to keep the lamp on after the
person has left the detected area.
C. Daylight Sensor
(Remote Option Only)
The sensor contains a daylight sensor in
order to allow a function only below a
defined brightness threshold.
BRIGHTNESS THRESHOLD SETUP –
DAYLIGHT: The lamp works always, even
during daylight.
Note: Three switches should be put in
OFF position when remote day light sensor
is not installed.
2O FC
5O FC
200 FC
300 FC
DISABLE
DETECTION AREA
12 3 12 3 12 3
HOLD TIME
DAYLIGHT SENSOR
I
II
III
IV
V
I
II
III
IV
VI
V
I
II
III
IV
V
100%
75%
50%
30%
10%
5 S
30 S
180 S
300 S
15 MIN
25 MIN
ON ON ON
Sensor Adjustments
v.092611–SS
Accessible Ceiling Installation:
Note:
T-Bar Option - Suspended Accessible Ceilings
Use optional T-bar bracket for support mounting to inverted T-grid lay in suspended ceilings.
Instructions
SpaceStation
i
TM
Phone: 605.542.4444
INSTALLATION | New Construction & Retrofit
WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to
ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published
installation instructions or any modifications to the product may damage the unit and will void the warranty.
Inccessible Ceiling Installation:
Note: Use Optional arm bracket for support mounting to structural blocking or stud also for retrofit installation
through existing ceiling hole (see page 8 also).
ARM Option - Gypsum Board and Other Inaccessible Ceilings
4
ARM
Adjustable Remote Mounting
to structural / blocking to
secure SpaceStation
v.092611–SS
5
Instructions
Power Connections
i
TM
Phone: 605.542.4444
INSTALLATION | Single Wiring Control Wiring Diagram
WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to
ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published
installation instructions or any modifications to the product may damage the unit and will void the warranty.
Single Lighting Circuit Control Wiring Diagram
Neutral
Load Output
Line Input Black
Line Black
Load Red
Neutral White
Yellow
Blue
SpaceStation
Occupancy
Sensor
STEP #3: Provide Power Connections
Branch circuit: building power only connections. Provide 120 VAC or 277 VAC uninterrupted power connections to terminate
within the ceiling mounted bracket junction box.
Black - Line Input
White - Neutral
Red - Line Output to Load
Load must not exceed 800 watts @ 120 VAC. Load
must not exceed 1200 watts @ 277 VAC. Loads in
excess must use the Command Module option for
higher wattage.
Note: Dimming ballast circuits must be controlled by
the Command Module option.
CLoad
Option (RDS)
B
Optional:
Remote Daylight Sensor
Override FDP
Concealed Wall Switch
Optional:
AOption (OR)
AOptional B – Optional C – Load Information
v.092611–SS
Instructions
Power Connections
i
TM
Phone: 605.542.4444
WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to
ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published
installation instructions or any modifications to the product may damage the unit and will void the warranty.
INSTALLATION | Multiple Wiring Control Wiring Diagram
Multiple Lighting Circuit Control Wiring Diagram
*Required for two or more circuits
Option (RDS)
Yellow
Blue
Line Input
Neutral
Line Black
Neutral White
Neutral White
Load Output Red
Command Module (CM) – # of poles
i.e. CM04 - 4 lighting circuit poles
ATTENTION!
Verify line voltage is compatible with electrically held coil voltage
(120 VAC or 277 VAC)
Specified: # of 20 AMP Circuits
6
Load must not exceed 800 watts @ 120
VAC. Load must not exceed 1200 watts
@ 277 VAC. Loads in excess must use
the Command Module option for higher
wattage.
§
Command Module option.
Dimming ballast circuits must be controlled by the
§Parallel connect multiple (two or more) sensors for areas
exceeding range coverage of one lighting sensor.
SpaceStation
Occupancy
Sensor
Override FDP
Concealed Wall Switch
Optional:
A
AOptional B – Optional C – Load Information D – Command Module Information
C
B
D
Option (OR)
Load
Optional:
Remote Daylight Sensor
TWO OR MORE SENSORS OPERATING TOGETHER
v.092611–SS
Instructions
Power Connections
i
7
TM
Phone: 605.542.4444
INSTALLATION | Adjustable Remote Mounting (ARM)
WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to
ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published
installation instructions or any modifications to the product may damage the unit and will void the warranty.
ARM – Adjustable Remote Mounting
ARM
Adjustable Remote Mounting
to structural / blocking to
secure SpaceStation
Provide flexible conduit
connections to existing
Lighting Branch Circuit
Existing
Ceiling
Opening
Lighting Branch Circuit
Lighting Branch Circuit
Existing Light Fixture,
J Box or Access panel
Existing Ceiling
Space Station Sensor
Note: Dimming ballast circuits must be controlled by the Command Module option.
The minimum size opening is 4
inches in diameter for insertion
of SpaceStation into an
inaccessible ceiling opening
v.092611–SS
Time Delay
IMPORTANT START-UP INFORMATION
The first time the sensor is powered-up the load will flash ON then OFF once, then there will be 10 seconds while the sensor
warms-up.
The SpaceStation automatically turns OFF the load after the coverage area has been vacant for the amount of time set in the
time delay. The minimum setting is 10 seconds, maximum is 30 minutes.
TROUBLESHOOTING
Quick Test:
Turn the time delay to minimum.
Move out of the sensor's view. Lights should turn OFF after 10 seconds.
Move into the sensor's view. The lights should turn ON.
Lights do not turn OFF:
1. If there is no motion in the set coverage area, reduce the sensitivity varying room panel adjusted positions.
2. Verify room panel adjustment positions.
3. Verify time delay and that there is no movement within the sensor's view for that time period.
FCC NOTICE
This device complies with part 15 of the FCC Rules, Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Warranty
All Concealite fixtures are tested and are guaranteed to be free from defective materials and workmanship for a period of three
years from date of shipment under normal operations and proper use. Correction of all defects shall be by replacement or
repair (at our option) and shall constitute fulfillment of all manufacturer's obligations. We will not allow any charge for labor,
materials, etc that does not have our written approval before the work is begun. Damage incurring in handling or in transit are
not covered by this guarantee. Any other warranty, expressed or implied, is hereby void. Modifications or changes to the
product or failure to follow installation instructions will void the warranty.
TM
Phone: 605.542.4444
Troubleshooting
Instructions
Troubleshooting
i
8v.092611–SS

Navigation menu